fwg double effect type€¦ · the donghwa entec df series fresh water generator utilizes the heat...

8
Engineering technology for the future Our company endeavor ceaselessly to develop new products and quality improvement Double Effect Type Water Maker & Fresh Water Generator www.dh.co.kr ISO 9001 Certificate No. A 0858 OHSAS 18001 Certificate No. C 0082 ISO 14001 Certificate No. B 0110

Upload: others

Post on 11-Jul-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FWG Double Effect Type€¦ · The DongHwa Entec DF Series Fresh Water Generator utilizes the heat from diesel engine jacket cooling water to produce pure drinkable water by evaporating

▶▶Engineering technology for the future

Our company endeavor ceaselesslyto develop new productsand quality improvement

Double Effect Type Water Maker & Fresh Water Generator

www.dh.co.krI S O 9 0 0 1Certificate No. A 0858

OHSAS 18001Certificate No. C 0082

I S O 14001Certificate No. B 0110

Page 2: FWG Double Effect Type€¦ · The DongHwa Entec DF Series Fresh Water Generator utilizes the heat from diesel engine jacket cooling water to produce pure drinkable water by evaporating

DOUBLE EFFECT TYPEWATER MAKER

The DongHwa Double Effect Type Water Maker is the equipment that convert seawater or exhausted dirty water to pure water for drinking, boiler make-up, domestic use on ship and small power station.At that time, seawater is evaporated at about 70°C, 45°C respectly as the one passed the inside of heater under the high vacuum condition and the separated pure vapor is converted to freshwater on condenser.(stage2)The other one is going to the heating medium of heater and then converted to freshwater.(stage 1)

The DongHwa Double Effect type water maker utilizes the waste heat from diesel engine jacket cooling water to convert seawater into freshwater by evaporating under low vacuum condition.The DongHwa Double Effect Type water maker is based on 3sets of Titanium plate heat exchangers as stage 1 evaporator, condenser and stage 2 evaporator respectively.

The evaporation chamber are kept under vacuum by a water ejector driven by the seawater outlet from the evaporator. The feed water evaporators when entering the evaporators due to the vacuum condition.

Water spray and droplet are partly removed from the vapor by the deflector mounted on top of each evaporator and partly by a build-in demister. The separated water droplets fall back into the brine, which is extracted from the lower part of the unit by means of the ejector.

The desalted vapor passing through the demister will be sucked into the condensers where it will be condensed by means of cold incoming seawater.

The pure distilled water will be taken out by means of freshwater pump.The pure water taken out from the condensers will be controlled by a salinometer to supervise that the salinity level be satisfactory. If the salinity exceeds the preset level, the solenoid valve in the discharge line of the distiller pump is automatically activated and faulty distillate is dumped into the drain. The salinometer has a built-in alarm and can be connected as remote alarm so that a too high salinity is registered immediately in the control room or where else needed.

Introduction

Heating Medium Outlet

InletHeating Medium

EVAPORATOR STAGE 1

CONDENSER

EVAPORATOR

STAGE 2

Cooling Medium Inlet

Distilled WaterOutlet

Cooling Medium Outlet

DF 35/60/2 Fresh Water Generator

Operating Principle

Page 3: FWG Double Effect Type€¦ · The DongHwa Entec DF Series Fresh Water Generator utilizes the heat from diesel engine jacket cooling water to produce pure drinkable water by evaporating

• Low installation costs• Reduced space requirement• Simple, unattended operation • Reliability • Easy operation & maintenance• Versatility for a wide range of applications• Fresh water quality

• Offshore Vessel (Drillship, Semi-Submigible Rig…)• Onshore remote location• Fishing Vessel• Cruiser

• Sea Water Ejector pump• Electric Booster Heater with Control Panel• Control panel with motor starters• Additional control equipment for easy running

Main Feature

Advantage Application Option

DF35/60/2L (mm) D (mm) H (mm) SD (mm) LD (mm) Weight (kg)

1480 1740 2800 1727 2427 2985

LD

H

SDLD

Page 4: FWG Double Effect Type€¦ · The DongHwa Entec DF Series Fresh Water Generator utilizes the heat from diesel engine jacket cooling water to produce pure drinkable water by evaporating

The main engine jacket cooling water circulates the outside of the vertical tube in heating section and the sea water to be distilled is sent to the bottom cover of this section. Then some of the sea water is converted into vapour when it goes up through the heated tubes. The vapour, through the demisters, is condensed on the outer surface of the tubes of the distilling condenser and the resultant distillate is led to the suction of the distillate pump. In the meantime the non-condensable gases and brine are extracted and discharged to overboard by the combination ejector.

Capacity Type Connection Jacket water flow80°C Heat consumption Ejector pump

capacityEjector pump

consumption(60Hz)FW pump

consumption(60Hz)

m³/24hr Single stage JIS m³/24hr KW m³× bar KW bar KW

5 DX-α -5 65 13 141 13×4.8 5.5 2 0.4

10 DX-α -10 80 26 282 24×4.8 6.6 3 1.5

15 DX-α -15 80 37 423 35×4.8 11 3 1.5

20 DX-α -20 100 54 564 44×4.8 11 3 1.5

25 DX-α -25 100 56 705 61×4.8 15 3 1.5

30 DX-α -30 125 69 846 75×4.8 18.5 3 1.5

35 DX-α -35 125 80 987 75×4.8 18.5 3 1.5

40 DX-α -40 125 85 1128 90×4.8 22 3 1.5

Technical Specification of DX-α Type

Fresh Water Generator

Working Principle

Tubular Type

Page 5: FWG Double Effect Type€¦ · The DongHwa Entec DF Series Fresh Water Generator utilizes the heat from diesel engine jacket cooling water to produce pure drinkable water by evaporating

IV

III

III I

II

VV DRIV'G S. WATER

JACKET WATER

JACKET WATER

TO OVERBOARD

FRESH WATER

9V

(VACUUM OPERATINGTYPE WITH PURGEMETER)

INJECTION UNITCHEMICAL

J.W. OUTLET

J.W. INLET

S.W. OUTLET

S.W. INLET

HIGH SALT WATERRETURN LINE

DISTIL

LED W

ATER

POWER SUPPLYALARM

4VV 4

PRODUCT WATER OUTLET

HEATER

SEA WATER FEEDING

-760mmHg~4K

0~150C

0~150C

-760mmHg~4K

0~100flC

DEFLECTOR

DEMISTER

PREHEATERCONDENSER

V6

CP

PUMPEJECTOR

AIR

SET P. 3.3KR

0~100flC

0~6K

VV6

T 0~100flCVACUUM BREAKERV6

-760mmHg~0K

BRINE

HEATING LINES.W LINE

YARD SUPPLY

F.W LINEELECTRIC WIRING

V2

T

V

A5 V

11V

P

S

8

WATER EJECTOR

12

VACUUM ADJUSTING VAVLE

LEGEND

R

S 2-WAY SOLENOID VALVE

RELIEF VALVESIGHT GLASS3-WAY COCK

PRESS. REGULAT. VALVESWING CHECK VALVEGLOBE VALVEP

C

V

T

SC

A

FM

THERMOMETER

AIR VENT VALVE

FLOW METERSALINITY CELL

ORIFICE

VACUUM GAUGECOMPOUND GAUGEPRESSURE GAUGE

3V

14

6V

V

C

T

C

T

T

BACK PRESS. MAX. 8 mAq

2V

V6

DISTILLATEPUMP

C

INDICATORSALINITY

1SC

V

13VFM

BACK PRESS. MAX. 18 mAq

V

-760mmHg~4K

Y&K

N P

Removal spaceof heater

of h

eate

rRe

mov

al s

pace

H

C

B

A

L

START/STOPOFF

ALARMSETINCDEC

JK-201 BUSAN GENERAL ELECTRIC

SALINITY CONTROLLER

±Ë«–º

Y&K

N P

Removal spaceof heater

of h

eate

rRe

mov

al s

pace

H

C

B

A

L

START/STOPOFF

ALARMSETINCDEC

JK-201 BUSAN GENERAL ELECTRIC

SALINITY CONTROLLER

±Ë«–º

Dimension List

Type L B H C AApprox. Weight(kg)

Empty Operation Ejector P/P

DX-α -5 1480 820 1430 1655 650 680 780 120

DX-α -10 1680 980 2005 1840 830 750 900 120

DX-α -15 1835 1030 1975 2030 850 850 1000 128

DX-α -20 1880 1060 1680 2250 990 1140 1350 140

DX-α -25 2050 1150 1850 2310 1200 1145 1370 175

DX-α -30 2250 1330 2080 2470 1500 1150 1400 175

DX-α -35 2400 1380 2100 2510 1500 1200 1570 175

DX-α -40 2500 1400 2205 2550 1500 1320 1650 187

Installation sketch of Fresh Water Generator

Page 6: FWG Double Effect Type€¦ · The DongHwa Entec DF Series Fresh Water Generator utilizes the heat from diesel engine jacket cooling water to produce pure drinkable water by evaporating

Plate Type

The DongHwa Entec DF Series Fresh Water Generator utilizes the heat from diesel engine jacket cooling water to produce pure drinkable water by evaporating sea water under high vacuum enabling the feed water to evaporate at temperatures below 48°C. Steam can also be used as the heat source instead of the hot jacket water.The DongHwa Entec DF Series Fresh Water Generator is based on 2 titanium plate heat exchangers acting as an evaporator and a condenser respectively.The evaporation chamber is kept under vacuum by a water ejector driven by the sea water outlet from condenser. A part of this heated sea water is used as feed water for the evaporator. The feed water evaporates when entering the evaporating chamber due to the vacuum condition. Water spray and droplets are partly removed from the vapour by the deflector mounted on top of the evaporator and partly by a build-in demister. The separated water droplets fall back into the brine, which is extracted from the sump by means of the ejector pump.The desalted vapour passing through the demister will be sucked into the plate condenser where it will be condensed by means of cold incoming salt water.The pure distilled water will be taken out by means of an integral fresh water pump. The pure water taken out from the condenser will be controlled by a salinometer to supervise that the pre-set salinity(1~10ppm) will be reached. If the salinity exceeds the specified level, the solenoid valve in the discharge line of the distiller pump is automatically activated and the faulty distillate is returned to the feed line.

Working Principle

Capacity Type Connection Jacket water flow (m³/24hr)

Heat consumption

Ejector pump capacity

Ejector pumpconsumption

(60Hz)

FW pumpconsumption

(60Hz)m³/24hr Single stage JIS 80°C 85°C 90°C KW m³× bar KW bar KW

3 DF3 40 8 6 5 110 8×4.0 3.6 3.0 0.755 DF3 40 10 8 6 160 13×4.0 4.8 3.0 0.757 DF7 40 12 10 8 220 18×4.0 6.6 3.0 0.7510 DF7 65 24 20 15 310 24×4.0 6.6 3.0 0.7512 DF7 65 26 23 16 360 29×4.0 11.0 3.0 0.7515 DF13 65 34 30 22 460 35×4.0 11.0 3.0 0.7518 DF13 65 38 35 25 540 40×4.0 11.0 3.0 0.7520 DF13 65 44 40 30 600 44×4.0 11.0 3.0 0.7525 DF13 80 54 48 35 750 58×4.0 15.0 3.0 0.7530 DF23 100 75 67 50 910 75×4.0 18.5 3.0 1.535 DF23 100 80 75 55 1080 88×4.0 22.0 3.0 1.540 DF35 125 86 80 60 1220 92×4.0 22.0 3.0 1.545 DF35 125 100 90 68 1360 95×4.0 22.0 3.0 1.550 DF35 150 112 100 74 1520 120×4.0 22.2 3.0 1.560 DF35 200 132 118 90 1850 140×4.0 24.0 3.0 1.5

Technical Specification of DF Type

Fresh Water Generator

Page 7: FWG Double Effect Type€¦ · The DongHwa Entec DF Series Fresh Water Generator utilizes the heat from diesel engine jacket cooling water to produce pure drinkable water by evaporating

50 LTR.

B= 400H= 570

FLOWMETER

VALVEVACUUM ADJUSTING

SIGHT GLASS

CONTROL PANEL

DISTILLATE PUMP

PURGE METER

ZINC

NAME PLATE

AIR SUCTION LINE

THERMOMETERTHERMOMETER

FEED VALVE

S.W FEED LINE

VALVESOLENOID

PRESS GAUGE

SALINITY SENSOR

FRESH WATER OUTLETFLOW METER

COMP. GAUGE

RETURN LINEHIGH SALINITY WATER

ORIFICECOMP. GAUGE

JACKET WATER INLET

SIGHT GLASS

SAFETY VALVE

JACKET WATER OUTLET

VACUUM BREAK VACUUM GAUGE

SUCTION LINEDISTILLED WATER

SEA WATER INLET

N.P

CHEMICAL DOSING UNIT

HANDLEDISTILLER SHELLDIVISION PLATE

DEMISTER

SEA WATER OUTLET

BRINE LINETWIN EJECTOR

DISTILLATE PUMP

END PLATE

FOLLOWER

SIDE MEMBER

SALINITY CONTROLLER

CONTROL PANEL

EVAPORATOR PLATES

CONDENSER PLATESDISTILLER BASE FLANGE

E

D

Spac

e for

demo

untin

g she

ll

C

B

A

N.P

Installation sketch of Fresh Water Generator

Dimension List

Type A B C D EApprox. Weight(kg)

Empty Operation

DF3/5 610 1013 810 935 1460 310 400

DF7/10 1020 1400 808 1042 1500 400 550

DF13/15 1020 1550 625 1065 1435 430 580

DF13/20 1080 1660 780 1280 1550 450 600

DF13/25 1080 1660 780 1450 1820 640 850

DF23/30 1276 1838 1210 1785 2255 675 900

DF23/35 1276 2100 900 1440 1710 700 950

DF35/40 1276 2200 900 1590 1810 850 1100

DF35/45 1276 2200 900 1700 2000 890 1200

DF35/50 1276 2200 900 1750 2100 910 1250

DF35/60 1276 2200 900 1800 2200 1130 1500

T

T

No.21 Ejector pump is option.Delivery extent Dong-hwa

Distilled water

Electrical wire / Dong-hwa

Electrical wire yard or customer

Flexible hosesChemical dosing equipment

Air / Vacuum

3164

308JACKET W.

2 18

1

3427

1717

12

17

T5

5

T5

T

20195

5

22COOLER

J.W OUTLET

24

23Bypass

J.W INLET

33

1434

32329

250.6 barmax.

7

engineMain or aux.

Jacket w.pump

2626

1.8 BarMax. back pressure

151633

109

1113

pressure max. 0.6 bar)(Please note the counter

4.8 bar2128

min. 0.1 bar

Over board

chestSea

NO. DESCRIPTION

1 EVAPORATOR

2 CONDENSER

3 TWIN EJECTOR

4 VACUUM GAUGE

5 THERMOMETER

6 DISTILLER BASE FLANGE

7 DISTILLER COVER

8 FLOW SIGHT GLASS

9 FRESH WATER PUMP

10 SALINITY SENSOR

11 SALINITY INDICATOR(controller)

12 SOLENOID V/V

13 CONTROL PANEL

14 PRESSURE GAUGE

15 PAN CHECK VALVE

16FLOW METER FOR DISTILLED WATER

17 CHEMICAL DOSING UNIT

NO. DESCRIPTION

18 DEMISTER

19 FEED VALVE

20 ORIFICE

21 EJECTOR PUMP(Option)

22 SEA WATER INLET

23 JACKET WATER INLET

24 JACKET WATER OUTLET

25 SEA WATER OUTLET

26 DISTILLED WATER OUTLET

27 BRINE OUTLET

28 SEA WATER FILTER (Max. 5mm)

29 AIR / VACUUM SUCTION LINE

30 SAFETY VALVE

31 VACUUM BREAKER

32 DRAIN LINE VALVE

33 COMPOUND GAUGE

34 CHECK VALVE

Page 8: FWG Double Effect Type€¦ · The DongHwa Entec DF Series Fresh Water Generator utilizes the heat from diesel engine jacket cooling water to produce pure drinkable water by evaporating

www. dh.co.kr

Head Office and Factory (Land Area: 15,574 m² / Building Area: 13,845 m²

Energy. Environmental Tec. Lab. (Land Area: 4,465 m² / Building Area: 3,365 m²

Hwajeon Office and Factory (Land Area: 20,127 m² / Building Area: 20,087 m²

DongHwa Entec (Shanghai) Co., Ltd. (Land Area: 33,350 m² / Building Area: 18,457 m²

DH N

o. 2

0151

0

Head Office and Factory7, Noksansandan 261-ro, Gangseo-gu, Busan, KoreaTEL : +82-51-970-1000 FAX : +82-51-970-1001Hwajeon Office and Factory20, Hwajeonsandan 1-ro 63beon-gil, Gangseo-gu, Busan, Korea TEL : +82-51-970-1100 FAX : +82-51-970-0710Energy · Environmental Technology Laboratory7, Gwahaksandan-ro 305beon-gil, Gangseo-gu, Busan, Korea TEL : +82-51-970-0711 FAX : +82-51-970-0730

DongHwa Pneutec75, Mieumsandan-ro 8beon-gil, Gangseo-gu, Busan, KoreaTEL : +82-51-974-4800 FAX : +82-51-974-4899DongHwa Giyeon80, Mieumsandan-ro 8beon-gil, Gangseo-gu, Busan, KoreaTEL : +82-51-899-9600 FAX : +82-51-899-9670DongHwa Entec (Shanghai) Co., Ltd.No.2508 JiangShan Road Luchaogang Shanghai 201308 P.R.China TEL : +86 (0)21-5197-5001 FAX : +86 (0)21-5197-5005GAS Entec Co., Ltd.No. #812, 813 and 814, Ace Hitech21, 48, Centum jungang-ro, Haeundae-gu, Busan, KoreaTEL : +82-51-714-3308 FAX : +82-70-7500-3979

Subsidiary Company