gardner denver centrifugal blowers

57
Gardner Denver Centrifugal Blowers Gardner Denver Centrifugal Blowers

Upload: alec-workman

Post on 03-Jan-2016

129 views

Category:

Documents


0 download

DESCRIPTION

Gardner Denver Centrifugal Blowers. Typical Applications. 1.Wastewater Treatment 2.Landfill Gas Extraction 3.Sulphur Recovery 4.Process Gas Boosting 5.Carbon Black 6.Fluidized Bed 7.Flue Gas De-Sulferization 8.Others. Typical Applications. Wastewater Treatment. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Gardner Denver Centrifugal Blowers

Gardner Denver Centrifugal BlowersGardner Denver Centrifugal Blowers

Page 2: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

1. Wastewater Treatment2. Landfill Gas Extraction3. Sulphur Recovery4. Process Gas Boosting5. Carbon Black6. Fluidized Bed7. Flue Gas De-Sulferization8. Others

Typical ApplicationsTypical Applications

Page 3: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Wastewater TreatmentWastewater Treatment

Typical ApplicationsTypical Applications

Page 4: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Page 5: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Wastewater Basins

Page 6: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Page 7: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Blowers in WastewaterAs Biochemical Oxygen Demand requirement changes in wastewater treatment, Gardner Denver multistage centrifugal blowers adjust easily. The Gardner Denver blowers save energy by eliminating the need for blowoff systems. Gardner Denver centrifugal blowers in wastewater service are designed for direct connection to an electric motor with a non-lubricated flexible drive coupling.

Page 8: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

BALANCING B.O.D.BALANCING B.O.D. (Biochemical Oxygen Demand)(Biochemical Oxygen Demand)

• Too little Dissolved Oxygen causes the microorganisms to perish resulting in a septic process.

• Too much Dissolved Oxygen is wasteful & can cause frothing.

• Blower flow control is critical.

Page 9: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

TYPES OF AERATION PROCESSES

• Coarse Bubble

• Fine Bubble

• Jet

• SBR

• Mechanical Aerators

Typical ApplicationsTypical Applications

Page 10: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Course Bubble

Fine Bubble

Jet Aeration

Sequence BatchReactor (SBR)

Typical Typical ApplicationsApplications

Page 11: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Aeration Processes:Comparison Factors

• Oxygen Transfer Performance

• Mixing Performance

• Efficiency

• Maintenance

• Reliability

• Installation Costs

Page 12: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

WHY UTILIZE A MULTISTAGE (MS) CENTRIFUGAL ?

VARIABLEFLOW & PRESSURE

LOW

MAINTENANCE

DURABLE

COMPETITIVEPRICING

SYSTEM

FRIENDLY

EFFICIENCY

Page 13: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

ADVANTAGES OF MULTISTAGE ADVANTAGES OF MULTISTAGE CENTRIFUGAL BLOWERSCENTRIFUGAL BLOWERS

• Flexibility - MS Blowers allow variable flow capability without a VFD, critical for maintaining sufficient amounts of dissolved oxygen at the minimum and maximum air requirement levels.

• Efficiency - MS Blowers maintain efficiency throughout their useful life. Additional energy savings are gained by inlet throttling and using custom design control schemes.

• Low Maintenance - With L-10 bearing life design and no wearing parts, MS Blowers operate virtually maintenance free. (Periodic lubrication)

• Low Noise - Most MS Blowers operate below 85 dba at 1 meter.

Page 14: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

HEAD LOSS

SYSTEM RESISTANCE

BLOWERCURVE

BLOWERCURVE

(Throttled)

VOLUME

PRESSURE

MULTISTAGE BLOWERMULTISTAGE BLOWER

Page 15: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

2006, 560 KW Multistage Blower2006, 560 KW Multistage Blower

Wastewater Treatment - Saudi Arabia

Page 16: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

CALCULATING BLOWER PRESSURE CALCULATING BLOWER PRESSURE REQUIREMENTSREQUIREMENTS

• Piping Losses - Including Filter & Valves.

• Diffuser Losses• Head (Depth of

Diffusers)

MaximumDepth

of Diffusers

InletPressureLosses

DischargePressureLosses

Diffuser Losses

Page 17: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

BASIN

BASIN33%

33%

33%

33%100%

INLETAIR

INLETAIR

INLETAIR

INLETAIR

Typical ApplicationsTypical Applications

Page 18: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Typical ApplicationsTypical Applications

Wastewater Treatment

Page 19: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

• Insures Accurate, Efficient & Safe Process Control Provides Installation Specific Control Diagrams

• Contains Components From Recognized Manufacturers (3) Blowers (1 per Basin)

•(2) DO Probes per Basin with Local Indication Check local regulations for back-up requirements

Dissolved Oxygen Probe

Basin

Inlet Valve

Local Protection*Surge/Overload

Blower Casing Vibration(PMC-BETA 440S)

M

2 DO Probes /Basinw/Local Indication

Inlet Filter/Silencer Manual WS BF ValveWS Check Vavle

Expansion JointsIncluded For

Inlet and Discharge

Dissolved Oxygen Probe

Basin

Inlet Valve

Local Protection*Surge/Overload

Blower Casing Vibration(PMC-BETA 440S)

M

Inlet Filter/Silencer Manual WS BF ValveWS Check Vavle

Expansion JointsIncluded For

Inlet and Discharge

Dissolved Oxygen Probe

Basin

Inlet Valve

Local Protection*Surge/Overload

Blower Casing Vibration(PMC-BETA 440S)

M

Inlet Filter/Silencer Manual WS BF ValveWS Check Vavle

Expansion JointsIncluded For

Inlet and Discharge

Custom Engineered Process Control System

Page 20: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Custom Engineered Process Control System

•Insures Accurate, Efficient, Safe Process Control

• Provides Installation Specific Control, Using Most Opened Valve Method

•With All Software Programs / Communicates With Local Panel’s

• (2 + 1 stand-by) Blowers Designed To Cover Air Requirements For (3) Basins

• (2) DO Probes per Basin with Local Indication

Optional By User

POWER BALANCE VALVEHAND OFF AUTO

BALANCE VAL 2OPEN JOG CLOSE

BALANCE VAL 1OPEN JOG CLOSE

F1 F2 F4 F5 F6F3 F7 F8 F9 F10

F11 F12 F14 F15 F16F13 F17 F18 F19 F20

BSSPALP TAB

SHFCTLLCK ALT

P8

P1

P6

P4

P3

P2

P5

P7

P10

ESC

DEL

INS

=

<

7

1

END

HOME

-

8

5

2

PAGE DOWN

PAGEUP

RETURN

>

9

6

3

0

4

P9

BasinValve

Dissolved Oxygen Probe Communication

Basin

Inlet ValveM

Local Protection

*Surge/OverloadBlower Bearing Vibration

Blower Bearing Temperature

M

Inlet ValveM

M

Inlet ValveM

M

Filter/Silencer

Local Protection

*Surge/OverloadBlower Bearing Vibration

Blower Bearing Temperature

Local Protection

*Surge/OverloadBlower Bearing Vibration

Blower Bearing Temperature

Page 21: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

THE COMPLETE BLOWER PACKAGETHE COMPLETE BLOWER PACKAGE

BlowerDriverCommon BaseCouplingAccessories

-Control -Panel-Valves-Etc

Page 22: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Paper Mill - Industrial Waste Water - Calli, Columbia

Page 23: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Paper Mill - Industrial Waste Water - Medellin Columbia

Page 24: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

OTHER APPLICATIONS FOR OTHER APPLICATIONS FOR WASTEWATER TREATMENT PLANTSWASTEWATER TREATMENT PLANTS

• Digester Gas - Includes options for corrosive gas; stainless steel shaft and/or impellers. Coated castings and special seals for minimal leakage around the bearings.

• Air Scour/Filter Backwash - Low pressure, short cycle application.

• Fluid Bed Incineration

Typical ApplicationsTypical Applications

Page 25: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Typical ApplicationsTypical Applications

Landfill Gas Extraction

Page 26: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

• Typical Gas: CH4, CO2, N2, etc

• Why Recover the Gas

- ENVIRONMENTAL HAZARD

- CH4 & C02 ‘GREENHOUSE’ GASES

- CH4 = NATURAL GAS

•APPLICATIONS

- Extraction to FLARES

- GAS BOOSTING to a Source of Beneficial Use

LANDFILL GAS APPLICATIONS

Page 27: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Brazilian Landfill

Page 28: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Typical ApplicationsTypical Applications

Landfill Gas Extraction

Page 29: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

HOFFMAN BLOWER

LANDFILL SITE

KNOCKOUT TANK

FLARE STATION

STORAGE TANKCOLLECTION SYSTEM

TYPICAL FLARE SYSTEM SCHEMATIC

Page 30: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Landfill Gas Storage Tank for Low Flow Conditions

Page 31: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

HOFFMAN BLOWER

LANDFILL SITE

KNOCKOUT TANK

FLARE STATION

COLLECTION SYSTEM

TYPICAL SCHEMATIC

HOFFMAN BLOWER

AFTERCOOLERINTERCOOLER

ELECTRIC GENERATION

DRYER

INDUSTRIAL USE OR STEAM APPLICATIONS

Page 32: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Landfill Gas - Brazil

Page 33: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Why Use Multistage Centrifugal Blowers?

• Robust construction designed for long term service in a corrosive environment.

• MS Blowers offer variable volume capability to handle various gas rates over the life of landfill.

• MS Blowers offer tight bearing seal designs for minimal gas leakage, critical for safety and gas usage.

Page 34: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Saturated Gas Corrosive Gas Condensate Build-Up Gas Leakage (Air into

the system)

Add Section Drains Add Coated Castings Add Coating / Drains Grease Units - Inlet Stuffing

Box and Closed Bearing Housings

Oil Units - 4 - Carbon Rings Seals and optional purge taps.

Blower Design Concerns

Page 35: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Design Considerations• Gas-tight seals

– To prevent leakage of air into the gas stream.

• Heresite coated heads and sections• Std. Aluminum impellers• Non-sparking coupling guards• Typical site --- 50%CO2 / 50% CH4

Typical ApplicationsTypical Applications

Landfill Gas Extraction

Page 36: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

MULTISTAGE BLOWERS AT A CALIFORNIA LANDFILL

DISCHARGEBUTTERFLY

VALVE

INLETBUTTERFLY

VALVE

Page 37: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Typical ApplicationsTypical Applications

Sulfur RecoverySulfur Recovery

Page 38: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Typical ApplicationsTypical Applications

Sulfur Recovery

Page 39: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Design Considerations• VERY DEPENDENT Upon Customer /

Engineer• Application varies from Combustion Air to Sour

Gas.• API Specifications may / may not be required.

Typical ApplicationsTypical Applications

Refinery - Sulfur Recovery / FGD

Page 40: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

API SPECIFICATIONS

API = THE AMERICAN PETROLEUM INSTITUE

API IS THE BIBLE OF THE REFINING INDUSTRY

COMMON SPECIFICATIONS

API- 617 FOR AXIAL AND CENTRIFUGAL COMPRESSORS(APPLIES TO GD MULTISTAGE)

API-672 (SINGLE STAGE UNITS)

API-673 (FANS IN REFINERIES)(THIS SPECIFICATION HAS BEEN WITHDRAWN BY API)

Typical ApplicationsTypical Applications

Page 41: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

API - 617 MAJOR REQUIREMENTS

Extensive Testing

ASME PTC-10 / Impeller Overspeed / Hydrotest (Special)

Rotor Balance (Special) 4 Hour Mechanical Run, etc.

Special Base

Checkered Decking with Drip Rim / Jackscrews

Designed for Grouting in place

Special Motor

API-541 or IEEE-841 Motors

And Many Other Requirements..

Typical ApplicationsTypical Applications

Page 42: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

API - 617 Major Exceptions

Lubrication System - API-617 Requires a forced Lubrication System as per API-619

Drive Coupling - API-617 Requires Drive Couplings be a Tapered fit as per API-671

and many others..

Typical ApplicationsTypical Applications

Page 43: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Model 2007 Multistage Centrifugal

Sulfur Recovery - Korea

Page 44: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Typical ApplicationsTypical Applications

Process Gas BoostingProcess Gas Boosting

Page 45: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Typical ApplicationsTypical Applications

Process Gas Boosting

Page 46: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

PROCESS GASSES- Carbon Dioxide (most common)- Oxygen- Steam- Nitrogen- No Lethal Gas

Typical ApplicationsTypical Applications

Page 47: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Typical ApplicationsTypical Applications

CARBON BLACKCARBON BLACK

Page 48: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Carbon Black - China

Page 49: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Typical ApplicationsTypical Applications

Fluidized Bed IncinerationFluidized Bed Incineration

Page 50: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Typical ApplicationsTypical Applications

Fluidized BedFluidized Bed

Page 51: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Typical ApplicationsTypical Applications

Power Plant Flue Gas Desulfurization

Page 52: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Power Plant - FGD

Typical ApplicationsTypical Applications

Page 53: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Power Plant - FGD

Typical ApplicationsTypical Applications

• Varying Methods– Ammonia Injection Systems– SO3 Injection Systems– Wet FGD Systems

Page 54: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Ammonia / SO3 Injection

Typical ApplicationsTypical Applications

Page 55: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

Other Applications

Typical ApplicationsTypical Applications

• De-watering Systems• Steam Boosting• Coke Oven Gas• Printing Press• Barge Venting• Vacuum Hold-down

• AirKnife Blow-off• Plating Tank

Aeration• Fluid Bed

Incinerator• Air Slides• CH4 Recovery -

Mining

Page 56: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

EXPERIENCE & RELIABILITY FACTOR • WASTEWATER

– Over 20,000 units around the world at WWTP plants• COMBUSTION AIR

– Blowers in Sulfur Recovery Unit’s and Carbon Black Plants Worldwide

• LANDFILL GAS– Blowers at the largest landfills in the world

• PROCESS– Supplier to Major Petrochemical Companies Worldwide

Page 57: Gardner Denver Centrifugal Blowers

APPLICATIONSAPPLICATIONS Gardner Denver CF SBU March, 2004

WE THANK YOU FOR YOUR TIME !!