6000 Precision Headspace Analyzers Features & Benefits Advanced Products for Measurement of O 2 and CO 2 in MAP/CAP Headspace Atmospheres Easy to set up and use Intuitive menu Auto calibrate Set tests for pass or fail Printer option Computer software option Applications Fresh Meat Cooked Meat Vegetables Salads Bakery Snack Foods Ready Meals Fish Pharmaceutical Vials Pharmaceutical Packaging

Upload: systechillinois

Post on 05-Aug-2015

228 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: Gas Analyzer 6000

6000 Precision Headspace Analyzers

Features & Benefits

Advanced Products for Measurement of O2 and CO2

in MAP/CAP Headspace Atmospheres

Easy to set up and use

Intuitive menu

Auto calibrate

Set tests for pass or fail

Printer option

Computer software option

Applications

Fresh Meat Cooked Meat Vegetables SaladsBakery Snack Foods Ready Meals Fish

Pharmaceutical Vials Pharmaceutical Packaging

Page 2: Gas Analyzer 6000

The Systech Illinois 6000 range offersthree different models toaccommodate your oxygen andcarbon dioxide measurements.

The compact enclosure maximizesspace on carts and table tops.Seamless cover design andpolycarbonate operator‘s panel shedsspills and resists most chemicals andsolvents.

6500 measures oxygen levels only

6700 measures carbon dioxide only

6600 measures both oxygen andcarbon dioxide concentrations.

Systech Illinois is recognized worldwide forits line of precision trace oxygen andcarbon dioxide analyzers. The SystechIllinois 6000 headspace analyzers offer highlevels of performance technology andoperator ease to fulfill the latest industrydemands for accuracy and reliability.

These highly advanced instruments areequipped with integral sampling systems,unique miniature zirconia and infraredsensors, and microprocessor control todeliver the most accurate and repeatableperformance possible. One touchautomated calibration and product analysismake these analyzers easy to use.

Rugged and compact epoxy clad cabinetry,seamless operator’s console andno-compromise engineering make theseinstruments ideal for both the laboratory orthe demanding climate of the productionfloor.

RS232 output prints product descriptionand sample data to 40 column thermaldesktop printer for hard copy of calibrationand test results. Prints test “Fail” accordingto user defined alarm settings.

RS232 output

Analysis of small sample volumes.Response is typically less than fiveseconds for oxygen and ten seconds forcarbon dioxide. Internal microprocessormanages calibration, autoranging, pumpspeed and duration and many otherfunctions to ensure consistent,error-free results.

Unique sensors

Precision flowmeter provides visualconfirmation of sample flow. Unlikewarning lights, users can monitor systemperformance and resolve potentialproblems before they occur.

Can Piercing Station

Locks most recent high or lowconcentration value. Bright, large characterdisplay is easy to read in any lightingcondition. Status lights indicate mode ofoperation.

With a single button the instrument selfcalibrates in just 30 seconds using ambientair.

Autocalibration

User friendly software parameters areeasy to enter and can be securedagainst accidental change.

Software

The robust sample probe is designed toaccept standard luer accessories andincludes easily replaced needles andparticulate filters. With a convenient sampleprobe holder to prevent needlecontamination and sample line damage.

Sample probe

Precision flowmeter

Display hold

Timed, automatic analysis is provided at thetouch of a button. Programable samplingduration and data integration make theseamong the most advanced headspaceanalyzers available.

Timed Analysis

Headspace samples can be injecteddirectly into the instrument whenautomated sampling is not practical.

The can piercing station is perfect forrigid packaging and has proven to bestable and reliable in hundreds ofdemanding applications.

Samples injected directly

Accessories

Automated package sampling is easy.Insert the sampling needle into thepackage and press analyze. Theinstrument does the rest; extractingthe sample, analyzing sensor outputand holding the results for viewing onthe bright autoranging display.

Automated sampling

Page 3: Gas Analyzer 6000

Systech Illinois reserve the right to change specifications without notice. 2010/09

Illinois Instruments, Inc (U.S)2401 Hiller Ridge RoadJohnsburg, Illinois 60051U.S.ATel: +1 815 344 6212Fax: +1 815 344 6332E-mail: [email protected]

Systech Instruments Ltd (UK)17 Thame Park Business Centre,Wenman Road,Thame, Oxfordshire OX9 3XATel: +44 (0)1844 216838Fax: +44 (0)1844 217220E-mail: [email protected]

Illinois Instruments (Thailand)6th fl Nopnarong Bldg No7Ladprao23, Jatujak, Bangkok 10900ThailandTel: +66 (0)2938 0798Fax: +66 (0)2938 1058E-mail: [email protected]

Systech Illinois (China)Room 519, No.3 FuCheng BuildingNo. 900 Quyang Rd, Hongkou district,Shanghai, China 200434Tel: +86 21 65533022Fax: +86 21 65539651Email: [email protected]

Oxygen Range Autoranging from 0.001 to 100% (models 6500 & 6600)

Carbon Dioxide Range Autoranging from 0.1 to 100% (models 6600 & 6700)

Displays Bright 4 Digit LED, Display Hold, Analyze, and Calibration StatusIndicators

Response Time <5 seconds (O2), <10 seconds (CO2)

Accuracy: Oxygen 10 to 100%, 0.2% absolute (max 2% of reading) and ±1 on the last digit.1 to 9.99%, 0.02% absolute (max 2% of reading) and ±1 on the last digit.0 to 0.999%, 0.005 % absolute and ±1 on the last digit.

Accuracy CO2 ±2% FSD

Ambient Temperature 41 to 104°F (+5 to 40°C)

Internal Sample Pump Processor Controlled Diaphragm Type

Syringe Injection Via Male Luer Syringe Adaptor (supplied)

Enclosure Epoxy Coated Steel, Polycarbonate Operators Panel

Dimensions 12 W x 10 D x 5.98 H (inches)

Weight 11.7 lbs

Options

Computer Interface RS232 Port for Computer/Data Printer

Rigid Pack Sampler Extracts samples from cans, jars, bottles, etc.Includes all necessary fittings and supplies.

Compact Printer 40 Column Thermal Desktop Printer

Power RequirementsMains power 110 / 220 VAC, 50 / 60 Hz. 100 Watt Maximum

Systech Illinois have over 25 years experience of providing analysis solutions for a wide rangeof industries. From our manufacturing plants in the U.S and UK we produce gas analyzers forindustrial process industries, headspace analyzers for monitoring gas flushing of food products,and our range of permeation analyzers.

OxygenThe oxygen detector utilizes a high purity,stabilised zirconia ceramic and platinumsensor maintained within a hightemperature environment. The sensorproduces a log output which is convertedand linearised to yield a digital readoutdirectly proportional to a sample’s oxygencontent.

Carbon DioxideThis sensor integrates a solid state infraredsource and detector into a single highperformance assembly. Narrow wavelengthfiltering and strict temperaturecompensation ensure that only carbondioxide is measured, even within complexgas mixtures. Precise signal conditioningand microprocessor control provide directdigital indication of CO2 concentrations.

Technical Specifications

Principle of operation