gas temperature measurements with high temporal · pdf filegas temperature measurements with...
TRANSCRIPT
![Page 1: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/1.jpg)
THE GERG ACADEMIC NETWORK EVENT 20103 & 4 June 2010
Brussels
Gas Temperature Measurements with High Temporal Resolution
Supervisor: Dr. Alexander FateevPhD Student: Vadim Evseev
DENMARK
![Page 2: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/2.jpg)
Introduction
The temperature of the flue gas is an important parameter of combustion
e.g. inside– a boiler of a power plant– cylinder of an internal-combustion engine– etc.
High spatial and temporal resolution is essential for accurate modeling of the process
The analysis helps in– further development of the models– optimization of boiler/engine design– etc.
![Page 3: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/3.jpg)
Lab
Lab
Introduction
Investigations under convenient laboratory conditions– are not sufficient to verify the models for
industrial combustors
Laser techniques offer great opportunities for combustion research but
– involve complicated and expensive set-up– are demanding to alignment– require more man-hours
The aim of this work is– to achieve high enough temporal resolution
for flue gas temperature measurement – to be able to apply commercially
the technique on industrial scale
Ind
ust
ryIn
du
stry
![Page 4: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/4.jpg)
Outline
Existing methodsContactNon-contact
The new systemNon-contact
– Optics + Grating spectrometer + IR Camera
Application on the industrial boilerMeasurement of the flue gas temperature with high temporal resolution
Future of the systemMultichannel spectrometer2D Tomography of a flame
![Page 5: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/5.jpg)
Thermocouples
Any junction of dissimilar metals will produce an electric potential related to temperature.
– inexpensive– can measure a wide range of temperatures– very simple setup– reliable results
A thermocouple measures its own temperature.– It gives somewhat integrated temperature of what it is in contact
with.– Response time: 15–60 s.
VoltageA metal
Another metal
t ºC
![Page 6: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/6.jpg)
Contact Methods
Suction pyrometers• thermocouple as a temperature sensor
radiation shield to avoid radiation from walls• cooling water to avoid radiation from the shield itself
– suction of the gas to enhance the contact with the thermocouple
Suctionof gas
Suctionof gas
Water CoolingWater Cooling
Water CoolingWater Cooling
Thermocouple
Voltage
Radiation shield
Boiler wall
FlameInsertion Probe
• Response time: 15–60 s– Unable to resolve fast temperature fluctuations
• A risk of catching a particle (like small piece of coal or wood)– Resulting in false temperature reading
![Page 7: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/7.jpg)
Spectroscopy
Absorptivity:How much of incident energy is absorbedat a certain wavelength λ?
However each sample also emits radiation by means of thermal radiation:– spectral radiance [ W / (m2 sr m) ]
How does the sample having temperature T emits radiation at a certain wavelength λ?
Kirchhoff established:The relation is a universal function of λ and T independent of a particular sample
Planck derived that function:Temperature can be calculated from measured
– spectral absorptivity– spectral radiance
Sample gasat T [K]
Sample gasat T [K]Iλ0Iλ0 IλIλ
λ λλ
λ
−α =
0
0( )I I
TI
λ( )R T
Sample gasat T [K]
Sample gasat T [K] Rλ(T)Rλ(T)
λ λ=π λ −2
1/5
( )( 1)
univc T
cR T
e
λλ
λ
=α
( )( )
( )univR T
R TT
![Page 8: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/8.jpg)
Non-Contact Methods
Insertion Probe + Spectrometer:• Easy to apply on industrial scale
when compared to laser-based techniques
• Temporal resolution is determined by the spectrometerFourier Transform Infra Red (FTIR) spectrometer: 2 Hz
– Still not enough to resolve fast temperature variations
Water CoolingWater Cooling
Water CoolingWater Cooling
CeramicProtection TubeOptical Fibre Field Of View
SpectrometerSpectrometerCalculationsCalculations
Spectral Radiance of the Gas
Spectral Radiance of the Gas t, °Ct, °C
Boiler wall
FlameInsertion Probe
![Page 9: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/9.jpg)
IR Emission Spectrum
0
5
10
15
20
25
2000 2500 3000 3500 4000 4500 5000 5500
H2OH2O
CO2CO2
COCO
BlackbodyBlackbody
H2OH2O
H2OH2O
A typical IR emission spectrum
of exhaust gas
A typical IR emission spectrum
of exhaust gas
CO2CO2
CxHyCxHy
Inte
nsi
tyIn
tensi
ty
Wavenumber, cm-1Wavenumber, cm-1
Greybody (particles)Greybody (particles)
![Page 10: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/10.jpg)
A New System
Source
512
pixe
ls
640 pixels
IR CameraIR Camera
IR SpectrumIR SpectrumIR ImageIR Image
down to7 µs
down to7 µs
Exposure time:
Exposure time:
Grating Spectrometer
Grating Spectrometer
Optical Fibre
![Page 11: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/11.jpg)
Industrial Boiler
The boiler of a biomass-coal power station
Thermal picture of the 40 MW flame
![Page 12: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/12.jpg)
Temperature Variations: A Straw Region Near the Burner Outlet
ParticlesParticles
Time [ms]Time [ms]
Tem
per
ature
[
°C ]
Tem
per
ature
[
°C ]
GasGas
Temporal resolution:
1 kHz
Temporal resolution:
1 kHz
![Page 13: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/13.jpg)
Temperature Variations: A Straw Region Near the Burner
Zoom In: 1kHz is enough to resolve temperature variations in the flame
ParticlesParticles
Time [ms]Time [ms]
Tem
per
ature
[
°C ]
Tem
per
ature
[
°C ]
GasGas
Temporal resolution:
1 kHz
Temporal resolution:
1 kHz
![Page 14: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/14.jpg)
Temperature Variations: Above the Straw Region
Here gas temperature is higher than that of particles. Most of heat is already released at this point, and hence gas is hotter than particles
ParticlesParticles
Time [ms]Time [ms]
Tem
per
ature
[
°C ]
Tem
per
ature
[
°C ]
GasGas
Temporal resolution:
1 kHz
Temporal resolution:
1 kHz
![Page 15: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/15.jpg)
Temperature Variations: Above the Straw Region
Zoom In: Particles do not undergo as huge temperature variations as gases do
ParticlesParticles
Time [ms]Time [ms]
Tem
per
ature
[
°C ]
Tem
per
ature
[
°C ]
GasGas
Temporal resolution:
1 kHz
Temporal resolution:
1 kHz
![Page 16: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/16.jpg)
Multichannel IR Spectrometer
A multichannel assembly allows to perform spectral measurements simultaneouslyfrom several line of sights
IR Camera
IR Camera
Grating Spectro-
meter
Grating Spectro-
meter
12 m
m
0.55 mm
Optical fibreOptical fibre
Slit
Simultaneous spectral measurementsSimultaneous spectral measurements
IR ImageIR Image
![Page 17: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/17.jpg)
2D Tomography of hot gases
Distribution in a section ofDistribution
in a section of
On-line 2D visualisationOn-line 2D
visualisation
Temperature
Temperature
ConcentrationConcentration
2D Tomography of hot gas in an exhaust pipe shows distribution of temperature or gas concentrations in a pipe cross section
![Page 18: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/18.jpg)
The Flat Flame Burner
To develop tomography tools we need a burner producing a stable, flat flame with known temperature profile
![Page 19: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/19.jpg)
The experimental setup
An optical setup with CaF2 lenses is used instead of optical fibers to improve the performance of the spectral measurements
IR CameraIR Camera
Grating Spectrometer
Grating Spectrometer
IR CameraIR Camera
Grating Spectrometer
Grating Spectrometer
OpticalSetup
OpticalSetup
OpticalSetup
OpticalSetup
BlackbodyBlackbody
![Page 20: Gas Temperature Measurements with High Temporal · PDF fileGas Temperature Measurements with High Temporal ... A thermocouple measures its own temperature. ... spectral measurements](https://reader031.vdocuments.net/reader031/viewer/2022030406/5a816ce77f8b9ada388d11d5/html5/thumbnails/20.jpg)
Conclusions
Temperature and concentrations of combustion gases can be measured from their emission spectra
e.g. spectrum of hot CO2 can be used for the measurements of flue gas temperature
Grating spectrometer + IR Camera is a smart solution to provide
spectral measurements with high temporal resolutionpossibility of commercial applications on an industrial scale
This system provides high flexibility and is promising in further developments
simultaneous spectral measurements at several lines of sight2D Tomography of hot gases and flames