gas ultrasonic flowmeter for permanent installation...disturbance signals, and to check each...

34
Technical Specification FLUXUS® G70x TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 1 FLUXUS FLUXUS Measurement with transducers mounted by PermaRail G704 G709 Gas Ultrasonic Flowmeter for Permanent Installation Designed for wall mounting or installation in 19'' rack systems Features Precise bi-directional and highly dynamic flow measure- ment with the non-intrusive clamp-on technology High precision at fast and slow flow rates, high temper- ature and zero point stability Automatic loading of calibration data and transducer detection for a fast and easy set-up (less than 5 min), providing precise and long-term stable results User-friendly design Transducers available for a wide range of inner pipe di- ameters ( ) and fluid temperatures ( ) approved transducers for hazard- ous areas available Measurement is unaffected by gas density, viscosity, composition, dust, humidity, temperature or pressure Applications Designed for industrial use in harsh environments, in gas processing and natural gas extraction, chemical industry and in the petroleum industry. Practical applications: Measurement on natural gas pipelines and in natural gas storage installations Measurement of synthesized gas and injection gas Measurement for the gas supply industry 0.3...63 in -40...+392 °F FM Class 1 Div. 2

Upload: others

Post on 05-Feb-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

  • Technical SpecificationFLUXUS® G70x

    TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 1

    FLUXUS

    FLUXUS

    Measurement with transducers mounted by PermaRail

    G704

    G709

    Gas Ultrasonic Flowmeter for Permanent Installation

    Designed for wall mounting or installation in 19'' rack systems

    Features

    • Precise bi-directional and highly dynamic flow measure-ment with the non-intrusive clamp-on technology

    • High precision at fast and slow flow rates, high temper-ature and zero point stability

    • Automatic loading of calibration data and transducer detection for a fast and easy set-up (less than 5 min), providing precise and long-term stable results

    • User-friendly design• Transducers available for a wide range of inner pipe di-

    ameters ( ) and fluid temperatures ( )

    • approved transducers for hazard-ous areas available

    • Measurement is unaffected by gas density, viscosity, composition, dust, humidity, temperature or pressure

    Applications

    Designed for industrial use in harsh environments, in gas processing and natural gas extraction, chemical industry and in the petroleum industry. Practical applications:• Measurement on natural gas pipelines and in natural

    gas storage installations• Measurement of synthesized gas and injection gas• Measurement for the gas supply industry

    0.3...63 in-40...+392 °F

    FM Class 1 Div. 2

  • FLUXUS® G70x Technical Specification

    Table of Contents

    TSFLUXUS_G7V1-5-1US_Lus, 2011-12-052

    Function ........................................................................................................................................................... 3Measurement Principle ..................................................................................................................................... 3Calculation of Volumetric Flow Rate ................................................................................................................. 3Number of Sound Paths.................................................................................................................................... 4Typical Measurement Setup ............................................................................................................................. 5Standard Volumetric Flow Rate ........................................................................................................................ 5

    Flow Transmitter ............................................................................................................................................. 6Technical Data .................................................................................................................................................. 6Dimensions ....................................................................................................................................................... 82 " Pipe Mounting Kit (optional)......................................................................................................................... 9Terminal Assignment ...................................................................................................................................... 10

    Transducers................................................................................................................................................... 12Transducer Selection ...................................................................................................................................... 12Transducer Order Code .................................................................................................................................. 15Technical Data ................................................................................................................................................ 16

    Transducer Mounting Fixture ...................................................................................................................... 23

    Coupling Materials for Transducers............................................................................................................ 25

    Damping Mats (optional) .............................................................................................................................. 26

    Connection Systems..................................................................................................................................... 28Transducer Cable............................................................................................................................................ 28

    Junction Box ................................................................................................................................................. 29Technical Data ................................................................................................................................................ 29Dimensions ..................................................................................................................................................... 292 " Pipe Mounting Kit (optional)....................................................................................................................... 29Terminal Assignment ...................................................................................................................................... 30

    Clamp-on Temperature Probe (optional) ................................................................................................... 31

    Wetted Temperature Probe (optional) ......................................................................................................... 33

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 3

    Technical Specification FLUXUS® G70x

    Function

    Measurement PrincipleIn order to measure the flow of a medium in a pipe, ultrasonic signals are used, employing the transit time dif-ference principle. Ultrasonic signals are emitted by a transducer installed on the pipe and received by a sec-ond transducer. These signals are emitted alternately in the flow direction and against it.As the medium in which the signals propagate is flowing, the transit time of the ultrasonic signals in the flowdirection is shorter than against the flow direction.The transit time difference, Δt, is measured and allows the flowmeter to determine the average flow velocityalong the propagation path of the ultrasonic signals. A flow profile correction is then performed in order to ob-tain the area averaged flow velocity, which is proportional to the volumetric flow rate.Two integrated microprocessors control the entire measuring process. This allows the flowmeter to removedisturbance signals, and to check each received ultrasonic wave for its validity which reduces noise.

    Calculation of Volumetric Flow Rate

    = kRe . A . ka . Δt/(2 . tfl)where

    Path of the ultrasonic signal Transit time difference Δt

    = volumetric flow ratekRe = fluid mechanics calibration factorA = cross-sectional pipe areaka = acoustical calibration factorΔt = transit time differencetfl = transit time in the medium

    ��

    ��

    ��

  • 4 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Number of Sound PathsThe number of sound paths is the number of transits of the ultrasonic signal through the medium in the pipe.Depending on the number of sound paths, the following methods of installation exist:• reflect mode

    The number of sound paths is even. Both of the transducers are mounted on the same side of the pipe. Correct positioning of the transducers is easier.

    • diagonal modeThe number of sound paths is odd. Both of the transducers are mounted on opposite sides of the pipe.

    • direct modeDiagonal mode with 1 sound path. This should be used in the case of a high signal attenuation by the medi-um, pipe or coatings.

    The preferred method of installation depends on the application. While increasing the number of sound pathsincreases the accuracy of the measurement, signal attenuation increases as well. The optimum number ofsound paths for the parameters of the application will be determined automatically by the transmitter.As the transducers can be mounted with the transducer mounting fixture in reflect mode or diagonal mode,the number of sound paths can be adjusted optimally for the application..

    a = transducer distance

    Reflect mode, number of sound paths: 2

    Diagonal mode, number of sound paths: 3

    Direct mode, number of sound paths: 1 Direct mode, number of sound paths: 1,negative transducer distance

    a

    a

    a > 0 a < 0

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 5

    Technical Specification FLUXUS® G70x

    Typical Measurement Setup

    Standard Volumetric Flow RateThe standard volumetric flow rate can be selected as physical quantity to be measured. It will be calculated in-ternally by:

    N = . p/pN . TN/T . 1/K:where

    The operational pressure p and the operational temperature T of the medium will be entered directly as fixedvalues into the transmitter.

    or:If inputs are installed (optional), pressure and temperature can be measured by the customer and fed in thetransmitter.

    The gas compressibility factor K will be entered in the transmitter:• as fixed value or• as approximation according to e.g. AGA8 or GERG

    Example of a measurement setup in reflect mode with connection of the inputsto an external process pressure and process temperature measurement for standard volumetric flow rate calculation

    N = standard volumetric flow rate= operating volumetric flow rate

    pN = standard pressure (absolute value)p = operating pressure (absolute value)TN = standard temperature in KT = operating temperature in KK = gas compressibility factor

    � � � � � � � � � � � � � � � �

    P T

    transducers damping mat

    transmitter

    RS232

    analog/binary outputs analog inputs

    power supply

    temperature probee.g. external pressure sensor

    RS485(optional)

    temperature probe

    V· V·

  • 6 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Flow Transmitter

    Technical DataFLUXUS G704 G709design standard field device 19 " module

    measurementmeasurement principle transit time difference correlation principleflow velocity 0.03 to 115 ft/s, depending on pipe diameterrepeatability 0.15 % of reading ±0.03 ft/smedium all acoustically conductive gases,

    e.g. nitrogen, air, oxygen, hydrogen, argon, helium, ethylene, propanetemperature compensation corresponding to the recommendations in ANSI/ASME MFC-5M-1985accuracyvolumetric flow rate ± 1 to 3 % of reading ±0.03 ft/s depending on application

    ± 0.5 % of reading ±0.03 ft/s with field calibrationflow transmitterpower supply 100 to 240 V/50 to 60 Hz or

    20 to 32 V DCpower consumption < 15 Wnumber of flow measuring channels

    1, optional: 2

    signal attenuation 0 to 100 s, adjustablemeasuring cycle (1 channel) 100 to 1000 Hzresponse time 1 s (1 channel), option: 70 mshousing material aluminum, powder coated aluminumdegree of protection NEMA 4 NEMA 1dimensions see dimensional drawing 42HP x 3U

    (without back panel)see dimensional drawing

    weight 6.2 lb 3.8 lbfixation wall mounting, optional: 2 " pipe mounting 19 " rack mountingoperating temperature -4 to +140 °Fdisplay 2 x 16 characters, dot matrix, backlightmenu language English, German, French, Dutch, Spanishexplosion protection (optional)

    FM

    marking NI/Cl. I,II,III/Div. 2/GP. A,B,C,D,E,F,G/T5 Ta = 60 °C

    -

    measuring functionsphysical quantities operating volumetric flow rate, standard volumetric flow rate, mass flow rate, flow velocitytotalizer volume, masscalculation functions average, difference, sum (2 measuring channels necessary)diagnostic functions sound speed, signal amplitude, SNR, SCNR, standard deviation of amplitudes and transit timesdata loggerloggable values all physical quantities, totalized values and diagnostic valuescapacity > 100 000 measured valuescommunicationinterface - process integration:

    optional: RS485 (Modbus, emitter) or HART- diagnosis: RS232

    - process integration:optional: RS485 (Modbus, emitter) or HART

    - diagnosis: RS232serial data kit (optional)software (all Windows™ ver-sions)

    -FluxData: download of measurement data, graphical presentation,conversion to other formats (e.g. for Excel™)

    -FluxKoef: creating medium data setsсable RS232 RS232adapter RS232 - USB RS232 - USB

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 7

    Technical Specification FLUXUS® G70x

    outputs (optional)The outputs are galvanically isolated from the transmitter.

    number on requestcurrent output

    current output- range 0/4 to 20 mA- accuracy 0.1 % of reading ±15 μA- active output Rext < 500 Ω- passive output Uext = 4 to 24 V, depending on Rext, Rext < 1 kΩcurrent output I1 in HART mode- range 4 to 20 mA- passive output Uext = 10 to 24 V

    voltage outputrange 0 to 1 V or 0 to 10 Vaccuracy 0 to 1 V: 0.1 % of reading ±1 mV

    0 to 10 V: 0.1 % of reading ±10 mVinternal resistance Ri = 500 Ω

    frequency outputrange 0 to 5 kHzopen collector 24 V/4 mA

    binary outputReed relay - 48 V/0.25 Aopen collector - 24 V/4 mAoptorelay 26 V/100 mA -binary output as alarm output- functions limit, change of flow direction or error limit, change of flow direction or errorbinary output as pulse output- pulse value 0.01 to 1000 units 0.01 to 1000 units- pulse width 1 to 1000 ms 80 to 1000 msinputs (optional)

    The inputs are galvanically isolated from the transmitter.number max. 4, on request

    temperature inputtype Pt100/Pt1000connection 4-wirerange -238 to +1040 °Fresolution 0.01 Kaccuracy ±0.01 % of reading ±0.03 K

    current inputaccuracy 0.1 % of reading ±10 μA 0.1 % of reading ±10 μAactive input Ui = 24 V, Ri = 50 Ω, Pi < 0.5 W,

    not short-circuit proofUi = 15 V, Ri = 50 Ω, Pi < 0.5 W,

    not short-circuit proof- range 0 to 20 mA 0 to 20 mApassive input Ri = 50 Ω, Pi < 0.3 W Ri = 50 Ω, Pi < 0.3 W- range -20 to +20 mA -20 to +20 mA

    voltage inputrange 0 to 1 Vaccuracy 0.1 % of reading ±1 mVinternal resistance Ri = 1 MΩ

    FLUXUS G704 G709

  • 8 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Dimensions

    FLUXUS G704

    �� 2.76

    0.39

    Ø 0.18

    6.42

    7.87

    11.310.43 screw holes for wall mounting

    thread: 6x M20 x 1.5cable gland: max. 6x 1/2 NPT

    11.5

    Ø 0

    .17

    7.3

    brackets for wall mounting (optional)

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 9

    Technical Specification FLUXUS® G70x

    2 " Pipe Mounting Kit (optional)

    FLUXUS G709

    in inch

    FLUXUS G704

    for vertical and horizontal pipes

    8.19

    5.08

    8.74

    0.59

    4.84

    4.33

    M2.

    51.

    73

    8.39

    5.08

    6.69

    7.8

  • 10 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Terminal Assignment

    2 The number, type and terminal assignment of the outputs and inputs will be customized.

    FLUXUS G704

    power supplyterminal strip KL3

    terminal connection AC connection DCPE earth earthN(-) neutral - DCL(+) phase + DC

    transducersterminal strip KL1

    extension cable (transducers ****LI*, *****52)transducer cable (transducers ****LI*)

    transducer cable (transducers *****52)

    measuring channel A measuring channel B measuring channel A measuring channel Bterminal connection terminal connection terminal connection

    AV signal BV signal X_AV X_BV SMB connectorAVS shield BVS shield X_AR X_BR SMB connector

    ARS shield BRS shieldAR signal BR signal

    outputs2 RS485 (optional)terminal strip KL4 terminal strip KL4

    terminal connection terminal connectionP1+ to P4+, P1- to P4- current output, voltage output, frequency output or binary output

    (optorelay)A+ signal +B- signal -

    P5a to P7a, P5b to P7b binary output (optorelay) 101 shield

    inputs2terminal strip KL2

    temperature probe passive current source active current sourceterminal connection connection with

    extension cableconnection of an active

    inputconnection of a passive

    inputwith connector

    without connector

    with connector

    without connector

    T1a to T4a red white red white not connected not connectedT1A to T4A red/blue black gray black - +T1b to T4b white/blue red blue red + not connectedT1B to T4B white green white green not connected -S1 to S4 shield - shield - not connected not connected

    � � ! � " # ! � "� � � � � � � � � � � � � � � � � � � $ � � $ � $

    � � � � � � � � � � � � � � � � % � � % � %

    � � $� � % � � $ � � � � % � � $ � � % � � $ � � � � %

    � � � � � � � � � � � � � � � � � � � � � � � �

    � # �

    � # �

    � # �

    � � �� � � � � � � � � � � � � � � � �

    & & � ' � � � � � & � & � � ' � � � � � �

    � # �

    � ( &

    � ( �

    � ( � &

    � ( � �

    � � � �

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 11

    Technical Specification FLUXUS® G70x

    2 The number, type and terminal assignment of the outputs and inputs will be customized.

    FLUXUS G709

    power supplyterminal strip KL2

    terminal connection AC terminal connection DCPE earth PE earthN neutral L- DC-L1 phase L+ DC+

    transducersterminal strip KL6, KL8

    extension cable (transducers ****LI*, *****52)transducer cable (transducers ****LI*)

    measuring channel A measuring channel Bterminal connection terminal connection

    AV signal BV signalAVS shield BVS shieldARS shield BRS shieldAR signal BR signal

    outputs2 RS485 (optional)terminal strip KL1 terminal strip KL4

    terminal connection terminal connectionP1+ to P7+, P1- to P7- current output, voltage output, frequency output or binary output

    (open collector, Reed relay)4A+ signal +4B- signal -

    P5a to P7a, P5b to P7b binary output (Reed relay) 43 shield

    inputs2terminal strip KL3

    temperature probe passive current source active current sourceterminal connection connection with

    extension cableconnection of an active

    inputconnection of a passive

    inputwith connector

    without connector

    with connector

    without connector

    T1a to T4a red white red white not connected not connectedT1A to T4A red/blue black gray black - +T1b to T4b white/blue red blue red + not connectedT1B to T4B white green white green not connected -S1 to S4 shield - shield - not connected not connected

    � # � # � # �� # �

    � # �� # �

    � � & � � � &

    � � � � � � �

    � # � � # �

    � ) � � #

    � �

    � �

    � �

    � �

    � � �

    � � �

    � � �

    � � �

    & �

    &

    � �

    ' �

    � & �

    � &

    � � �

    � ' �

    � �

    � �

    � � �

    � �

    � �

    � �

    # �

    # �

    # �

    � � %

    � %

    � �

    � %

    � � �

    � � �

    � �

    � � �

    � � �

    � � �

    � � $

    � $

    � �

    � $

    � � �

    � � �

    � �

    � � �

    � � �

    � � �

    � �

    � � �

    � � �

    � �

    � �

    � � �

    � � �

    � �

    � �

    � �

    � � %

    � � $

    � � $

    � �

    � � %

    � � $

    � � $

    � � %

    � �

    � � %

  • 12 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Transducers

    Transducer Selection

    Step 1aSelect a Lamb wave transducer:

    Step 1bIf the pipe wall thickness is not in the range of the Lamb wave transducers, select a shear wave transducer:

    Step 2inner pipe diameter d dependent on the flow velocity v of the medium in the pipeThe transducers are selected from the characteristics (see next page). Lamb wave transducers are selectedfrom the left column, shear wave transducers from the right column.Lamb wave transducers: If the values d and v are not in the range, diagonal mode with 1 sound path may beused, i.e. the same characteristics can be used with doubling the inner pipe diameter. If the values are still notin the range, shear waves transducers regarding the pipe wall thickness have to be selected in step 1b.

    transducer order code

    GLG 0.43 0.91

    GLH 0.28 0.59

    GLK 0.16 0.35

    GLM 0.08 0.2

    GLP 0.04 to 0.12

    GLQ 0.02 to 0.04

    0.2 0.4 0.6 0.8 1pipe wall thickness [in]

    transducer order code

    GSG 0.55 0.91

    GSK 0.2 0.35

    GSM 0.1 0.2

    GSP 0.06 0.12

    0.2 0.4 0.6 0.8 1pipe wall thickness [in]

    recommended possible

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 13

    Technical Specification FLUXUS® G70x

    Lamb wave transducer1 shear wave transducer1

    GLG GSG

    GLH

    GLK GSK

    GLM GSM

    GLPGSP

    GLQ

    1 inner pipe diameter and max. flow velocity for a typical application with natural gas, nitrogen, oxygen in reflect mode with 2 soundpaths (Lamb wave transducers)/1 sound path (shear wave transducers)

    0 20 40 60 80 100 120v�ft�s�

    10

    20

    30

    40

    Dmax�in�GRG

    0 20 40 60 80 100 120vmax�ft�s�

    10

    20

    30

    40

    Dmax�in�

    0 20 40 60 80 100 120vmax�ft�s�

    10

    20

    30

    40

    Dmax�in�GRH

    0 20 40 60 80 100 120vmax�ft�s�

    5

    10

    15

    20Dmax�in�

    0 20 40 60 80 100 120vmax�ft�s�

    5

    10

    15

    20Dmax�in�

    0 20 40 60 80 100 120vmax�ft�s�

    1

    2

    3

    4

    Dmax�in�GRM

    0 20 40 60 80 100 120vmax�ft�s�

    1

    2

    3

    4

    Dmax�in�GDM

    0 20 40 60 80 100 120vmax�ft�s�

    0.5

    1.0

    1.5

    2.0

    2.5Dmax�in�

    GRP

    0 20 40 60 80 100 120vmax�ft�s�

    0.5

    1.0

    1.5

    2.0

    2.5Dmax�in�

    GDP

    0 20 40 60 80 100 120vmax�ft�s�

    0.5

    1.0

    1.5

    2.0

    2.5Dmax�in�

    GRQ

  • 14 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Step 3min. medium pressure

    Example

    Step 4for the characters 4 to 11 of the transducer order code (operating temperature, explosion protection, connec-tion system, extension cable) see page 15

    Step 5for the technical data of the selected transducer see page 16 et seqq.

    Lamb wave transducer shear wave transducertransducer order code

    medium pressure1 [psi] transducer order code

    medium pressure1 [psi]metal pipe plastic pipe metal pipe plastic pipe

    min. min. extended min. min. min. extended min.GLG 218 145 15 GSG 435 290 15

    GLH 218 145 15 GSK 435 290 15

    GLK 218 (d > 4.7 in)145 (d < 4.7 in)

    145 (d > 4.7 in)73 (d < 4.7 in)

    15 GSM 435 290 15

    GLM 145 (d > 2.4 in)73 (d < 2.4 in)

    - 15 GSP 435 290 15

    GLP 145 (d > 1.4 in)73 (d < 1.4 in)

    - 15

    GLQ 145 (d > 0.59 in)73 (d < 0.59 in)

    - 15

    1 depending on application, typical absolute value for natural gas, nitrogen, compressed aird = inner pipe diameter

    step1 pipe wall thickness in 0.47 0.47 0.47 1.2

    selected transducer GLG or GLH GLG or GLH GLG or GLH GS2 inner pipe diameter in 31.5 23.6 31.5 11.8

    max. flow velocity ft/s 49 49 98 49selected transducer GLG GLG or GLH values not in the range

    of the characteristics, but by using diagonal mode with 1 sound path, the inner pipe diameter in the cha-racteristics is doubled:GLG

    GSK

    3 min. medium pressure psi 247 247 247 508selected transducer GLG GLG or GLH

    influence of acoustic noise is reduced with increased transducer frequency, thus recommended:GLH

    GLG GSK

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 15

    Technical Specification FLUXUS® G70x

    Transducer Order Code1, 2 3 4 5, 6 7, 8 9 to 11 12, 13 no. of character

    trans

    duce

    r

    trans

    duce

    r fre

    quen

    cy

    - oper

    atin

    g te

    mpe

    ratu

    re

    expl

    osio

    npr

    otec

    tion

    conn

    ectio

    nsy

    stem

    - exte

    nsio

    n ca

    ble

    / optio

    n

    description

    GL set of ultrasonic flow transducers for gas measurement, Lamb wave

    GS set of ultrasonic flow transducers for gas measurement, shear wave

    G 0.2 MHz

    H 0.3 MHz (Lamb wave only)

    K 0.5 MHz

    M 1 MHz

    P 2 MHz

    Q 4 MHz (Lamb wave only)

    N normal temperature range

    E extended temperature range (shear wave transducers with trans-ducer frequency M, P)

    F2 FM Class I Div. 2

    NN not explosion proof

    TS direct connection or connection via junction box

    XXX cable length in m, for max. length of extension cable see page 28

    0 m: without junction box> 0 m: with junction box JB03 or JBP3 (transducers NEMA 6P)

    IP68 degree of protection NEMA6P

    OS housing with stainless steel 316

    example

    GL K - N F2 TS - 030 Lamb wave transducer 0.5 MHz, normal temperature range, FM Class I Div. 2, connection system TS with junction box JB03 and extension cable 30 m (98 ft)

    - - /

  • 16 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Technical Data

    Shear Wave Transducers (FM or not explosion proof)technical type GDG1N52 GDK1N52order code GSG-NF2TS

    GSG-NF2TS/OSGSG-NNNTSGSG-NNNTS/OS

    GSK-NF2TSGSK-NF2TS/OSGSK-NNNTSGSK-NNNTS/OS

    transducer frequency MHz 0.2 0.5medium pressure1min. extended psi metal pipe: 290 metal pipe: 290min. psi metal pipe: 435

    plastic pipe: 15metal pipe: 435plastic pipe: 15

    inner pipe diameter d2min. extended in 9.8 2.8min. recommended in 15 3.1max. recommended in 31.9 19.7max. extended in 43.3 28.3pipe wall thicknessmin. in 0.55 0.2max. in - -materialhousing PEEK with stainless steel

    cap 304, option OS: 316LPEEK with stainless steel cap 304, option OS: 316L

    contact surface PEEK PEEKdegree of protection NEMA 6 NEMA 6transducer cabletype 1699 1699length ft 16 16dimensionslength l in 5.1 4.98width b in 2.01 2.01height h in 2.64 2.66dimensional drawing

    operating temperaturemin. °F -40 -40max. °F +266 +266temperaturecompensation

    x x

    explosion protection

    FM

    transducer GSG-NF2TSGSG-NF2TS/OS

    GSK-NF2TSGSK-NF2TS/OS

    explosion protection temperaturemin. °F -40 -40max. °F +257 +257marking NI/Cl. I,II,III/Div. 2 /

    GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

    NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

    Temp. Codes dwg 3860type of protection non incendive non incendive

    1 depending on application, typical absolute value for natural gas, nitrogen, compressed air2 shear wave transducer:

    typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on requestpipe diameter min. recommended/max. recommended/max. extended: in diagonal mode and for a flow velocity of 49 ft/s

    l

    hb

    l

    hb

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 17

    Technical Specification FLUXUS® G70x

    Shear Wave Transducers FM or not explosion proof)technical type GDM2N52 GDP2N52order code GSM-NF2TS

    GSM-NF2TS/OSGSM-NNNTSGSM-NNNTS/OS

    GSP-NF2TSGSP-NF2TS/OSGSP-NNNTSGSP-NNNTS/OS

    transducer frequency MHz 1 2medium pressure1min. extended psi metal pipe: 290 metal pipe: 290min. psi metal pipe: 15 metal pipe: 15inner pipe diameter d2min. extended in 1.2 0.59min. recommended in 1.6 0.79max. recommended in 3.1 1.6max. extended in 4.7 2.4pipe wall thicknessmin. in 0.1 0.06max. in - -materialhousing PEEK with stainless steel

    cap 304, option OS: 316LPEEK with stainless steel cap 304, option OS: 316L

    contact surface PEEK PEEKdegree of protection NEMA 6 NEMA 6transducer cabletype 1699 1699length ft 13 13dimensionslength l in 2.46 2.46width b in 1.26 1.26height h in 1.59 1.59dimensional drawing

    operating temperaturemin. °F -40 -40max. °F +266 +266temperaturecompensation

    x x

    explosion protection

    FM

    transducer GSM-NF2TSGSM-NF2TS/OS

    GSP-NF2TSGSP-NF2TS/OS

    explosion protection temperaturemin. °F -67 -67max. °F +374 +374marking NI/Cl. I,II,III/Div. 2 /

    GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

    NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

    Temp. Codes dwg 3860type of protection non incendive non incendive

    1 depending on application, typical absolute value for natural gas, nitrogen, compressed air2 shear wave transducer:

    typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on requestpipe diameter min. recommended/max. recommended/max. extended: in diagonal mode and for a flow velocity of 49 ft/s

    l

    hb

    l

    hb

  • 18 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Shear Wave Transducers (not explosion proof, NEMA 6P)technical type GDG1LI8 GDK1LI8 GDM2LI8 GDP2LI8order code GSG-NNNTS/IP68 GSK-NNNTS/IP68 GSM-NNNTS/IP68 GSP-NNNTS/IP68transducer frequency MHz 0.2 0.5 1 2medium pressure1min. extended psi metal pipe: 290 metal pipe: 290 metal pipe: 290 metal pipe: 290min. psi metal pipe: 435

    plastic pipe: 15metal pipe: 435plastic pipe: 15

    metal pipe: 435plastic pipe: 15

    metal pipe: 435plastic pipe: 15

    inner pipe diameter d2min. extended in 9.8 2.8 1.2 0.59min. recommended in 15 3.1 1.6 0.79max. recommended in 31.9 19.7 3.1 1.6max. extended in 43.3 28.3 4.7 2.4pipe wall thicknessmin. in 0.55 0.2 0.1 0.06max. in - - - -materialhousing PEEK with stainless steel

    cap 316TiPEEK with stainless steel cap 316Ti

    PEEK with stainless steel cap 316Ti

    PEEK with stainless steel cap 316Ti

    contact surface PEEK PEEK PEEK PEEKdegree of protection NEMA 6P NEMA 6P NEMA 6P NEMA 6Ptransducer cabletype 2550 2550 2550 2550length ft 39 39 39 39dimensionslength l in 5.06 5.06 2.76 2.76width b in 2.13 2.13 1.26 1.26height h in 3.29 3.29 1.81 1.81dimensional drawing

    operating temperaturemin. °F -40 -40 -40 -40max. °F +212 +212 +212 +212temperaturecompensation

    x x x x

    1 depending on application, typical absolute value for natural gas, nitrogen, compressed air2 shear wave transducer:

    typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on requestpipe diameter min. recommended/max. recommended/max. extended: in diagonal mode and for a flow velocity of 49 ft/s

    l

    hb

    l

    hb

    l

    hb

    l

    hb

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 19

    Technical Specification FLUXUS® G70x

    Shear Wave Transducers (extended temperature range, FM or not explosion proof)technical type GDM2E52 GDP2E52order code GSM-EF2TS

    GSM-EF2TS/OSGSM-ENNTSGSM-ENNTS/OS

    GSP-EF2TSGSP-EF2TS/OSGSP-ENNTSGSP-ENNTS/OS

    transducer frequency MHz 1 2medium pressure1min. extended psi metal pipe: 290 metal pipe: 290min. psi metal pipe: 435

    plastic pipe: 15metal pipe: 435plastic pipe: 15

    inner pipe diameter d2min. extended in 1.2 0.59min. recommended in 1.6 0.79max. recommended in 3.1 1.6max. extended in 4.7 2.4pipe wall thicknessmin. in 0.1 0.06max. in - -materialhousing PI with stainless steel

    cap 304, option OS: 316LPI with stainless steel cap 304, option OS: 316L

    contact surface PI PIdegree of protection NEMA 4 NEMA 4transducer cabletype 6111 6111length ft 13 13dimensionslength l in 2.46 2.46width b in 1.26 1.26height h in 1.59 1.59dimensional drawing

    operating temperaturemin. °F -22 -22max. °F +392 +392temperaturecompensation

    x x

    FM

    transducer GSM-EF2TSGSM-EF2TS/OS

    GSP-EF2TSGSP-EF2TS/OS

    explosion protection temperaturemin. °F -49 -49max. °F +455 +455marking NI/Cl. I,II,III/Div. 2 /

    GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

    NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

    Temp. Codes dwg 3860type of protection non incendive non incendive

    1 depending on application, typical absolute value for natural gas, nitrogen, compressed air2 shear wave transducer:

    typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on requestpipe diameter min. recommended/max. recommended/max. extended: in diagonal mode and for a flow velocity of 49 ft/s

    l

    hb

    l

    hb

  • 20 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Lamb Wave Transducers (FM or not explosion proof)technical type GRG1N52 GRH1N52 GRK1N52order code GLG-NF2TS

    GLG-NF2TS/OSGLG-NNNTSGLG-NNNTS/OS

    GLH-NF2TSGLH-NF2TS/OSGLH-NNNTSGLH-NNNTS/OS

    GLK-NF2TSGLK-NF2TS/OSGLK-NNNTSGLK-NNNTS/OS

    transducer frequency MHz 0.2 0.3 0.5medium pressure1min. extended psi metal pipe: 145 metal pipe: 145 metal pipe:

    145 (d > 4.7 in)73 (d < 4.7 in)

    min. psi metal pipe: 218plastic pipe: 15

    metal pipe: 218plastic pipe: 15

    metal pipe:218 (d > 4.7 in)145 (d < 4.7 in)plastic pipe: 15

    inner pipe diameter d2min. extended in 7.5 4.7 2.4min. recommended in 8.7 5.5 3.1max. recommended in 35.4 23.6 11.8max. extended in 63 39.4 19.7pipe wall thicknessmin. in 0.43 0.28 0.16max. in 0.91 0.59 0.35materialhousing PPSU with stainless steel

    cap 304, option OS: 316LPPSU with stainless steel cap 304, option OS: 316L

    PPSU with stainless steel cap 304, option OS: 316L

    contact surface PPSU PPSU PPSUdegree of protection NEMA 6 NEMA 6 NEMA 6transducer cabletype 1699 1699 1699length ft 16 16 16dimensionslength l in 5.06 5.06 5.06width b in 2.01 2.01 2.01height h in 2.66 2.66 2.66dimensional drawing

    operating temperaturemin. °F -40 -40 -40max. °F +338 +338 +338temperaturecompensation

    x x x

    explosion protection

    FM

    transducer GLG-NF2TSGLG-NF2TS/OS

    GLH-NF2TSGLH-NF2TS/OS

    GLK-NF2TSGLK-NF2TS/OS

    explosion protection temperaturemin. °F -40 -40 -40max. °F +329 +329 +329marking NI/Cl. I,II,III/Div. 2 /

    GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

    NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

    Temp. Codes dwg 3860

    NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

    Temp. Codes dwg 3860type of protection non incendive non incendive non incendive

    1 depending on application, typical absolute value for natural gas, nitrogen, compressed air2 Lamb wave transducer:

    typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on requestpipe diameter min. recommended/max. recommended: in reflect mode and for a flow velocity of 49 ft/spipe diameter max. extended: in diagonal mode and for a flow velocity of 82 ft/s

    l

    hb

    l

    hb

    l

    hb

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 21

    Technical Specification FLUXUS® G70x

    Lamb Wave Transducers (FM or not explosion proof)technical type GRM1N52 GRP1N52 GRQ1N52order code GLM-NF2TS

    GLM-NF2TS/OSGLM-NNNTSGLM-NNNTS/OS

    GLP-NF2TSGLP-NF2TS/OSGLP-NNNTSGLP-NNNTS/OS

    GLQ-NF2TSGLQ-NF2TS/OSGLQ-NNNTSGLQ-NNNTS/OS

    transducer frequency MHz 1 2 4medium pressure1min. extended psi - - -min. psi metal pipe:

    145 (d > 2.4 in)73 (d < 2.4 in)plastic pipe: 15

    metal pipe:145 (d > 1.4 in)73 (d < 1.4 in)plastic pipe: 15

    metal pipe:145 (d > 0.59 in)73 (d < 0.59 in)plastic pipe: 15

    inner pipe diameter d2min. extended in 1.2 0.59 0.28min. recommended in 1.6 0.79 0.39max. recommended in 3.5 2 0.87max. extended in 5.9 2.8 1.4pipe wall thicknessmin. in 0.08 0.04 0.02max. in 0.2 0.12 0.04materialhousing PPSU with stainless steel

    cap 304, option OS: 316LPPSU with stainless steel cap 304, option OS: 316L

    PPSU with stainless steel cap 304, option OS: 316L

    contact surface PPSU PPSU PPSUdegree of protection NEMA 4 NEMA 4 NEMA 4transducer cabletype 1699 1699 1699length ft 13 13 9dimensionslength l in 2.91 2.91 1.65width b in 1.26 1.26 0.87height h in 1.59 1.59 1dimensional drawing

    operating temperaturemin. °F -40 -40 -40max. °F +338 +338 +338temperaturecompensation

    x x x

    explosion protection

    FM

    transducer GLM-NF2TSGLM-NF2TS/OS

    GLP-NF2TSGLP-NF2TS/OS

    GLQ-NF2TSGLQ-NF2TS/OS

    explosion protection temperaturemin. °F +67 +67 +67max. °F +329 +329 +329marking NI/Cl. I,II,III/Div. 2 /

    GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

    NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

    Temp. Codes dwg 3860

    NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

    Temp. Codes dwg 3860type of protection non incendive non incendive non incendive

    remark on request1 depending on application, typical absolute value for natural gas, nitrogen, compressed air2 Lamb wave transducer:

    typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on requestpipe diameter min. recommended/max. recommended: in reflect mode and for a flow velocity of 49 ft/spipe diameter max. extended: in diagonal mode and for a flow velocity of 82 ft/s

    l

    hb

    l

    hb

    l

    hb

  • 22 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Lamb Wave Transducers (not explosion proof, NEMA 6P)technical type GRG1LI8 GRH1LI8 GRK1LI8order code GLG-NNNTS/IP68 GLH-NNNTS/IP68 GLK-NNNTS/IP68transducer frequency MHz 0.2 0.3 0.5medium pressure1min. extended psi metal pipe: 145 metal pipe: 145 metal pipe:

    145 (d > 4.7 in)73 (d < 4.7 in)

    min. psi metal pipe: 218plastic pipe: 15

    metal pipe: 218plastic pipe: 15

    metal pipe:218 (d > 4.7 in)145 (d < 4.7 in)plastic pipe: 15

    inner pipe diameter d2min. extended in 7.5 4.7 2.4min. recommended in 8.7 5.5 3.1max. recommended in 35.4 23.6 11.8max. extended in 63 39.4 19.7pipe wall thicknessmin. in 0.43 0.28 0.16max. in 0.91 0.59 0.35materialhousing PPSU with stainless steel cap

    316TiPPSU with stainless steel cap 316Ti

    PPSU with stainless steel cap 316Ti

    contact surface PPSU PPSU PPSUdegree of protection NEMA 6P NEMA 6P NEMA 6Ptransducer cabletype 2550 2550 2550length ft 39 39 39dimensionslength l in 5.65 5.65 5.65width b in 2.13 2.13 2.13height h in 3.29 3.29 3.29dimensional drawing

    operating temperaturemin. °F -40 -40 -40max. °F +212 +212 +212temperaturecompensation

    x x x

    1 depending on application, typical absolute value for natural gas, nitrogen, compressed air2 Lamb wave transducer:

    typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on requestpipe diameter min. recommended/max. recommended: in reflect mode and for a flow velocity of 49 ft/spipe diameter max. extended: in diagonal mode and for a flow velocity of 82 ft/s

    l

    hb

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 23

    Technical Specification FLUXUS® G70x

    Transducer Mounting FixtureOrder Code1, 2 3 4 5 6 7 to 9 10, 11 no. of character

    trans

    duce

    r m

    ount

    ing

    fixtu

    re

    trans

    duce

    r

    - mea

    surin

    g m

    ode

    size - fixat

    ion

    oute

    r pip

    e di

    amet

    er

    / optio

    n

    description

    PL PermaLok

    VL PermaRail

    K transducers with transducer frequency G, H, K

    M transducers with transducer frequency M, P

    Q transducers with transducer frequency Q

    D reflect mode or diagonal mode/direct mode

    R reflect mode

    S small

    M medium

    L large

    S tension straps

    W welding

    N without fixation

    SK1 0.5 to 2.5 in

    SK2 3 to 6 in

    SK3 8 to 10 in

    SK4 12 to 18 in

    SK5 20 to 36 in

    SK6 42 to 100 in

    IP68 degree of protection NEMA6P

    OS housing with stainless steel 316

    Z special design

    example

    VL K - D S - S 200 PermaRail and tension straps for transducers with transducer frequency G, H, K

    - - /

  • 24 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    PermaRail VL material: stainless steel 304, 301option OS: 316, 316L, 17-7PHinner length:VLK: 13.7 in,option IP68: 14.5 inVLM: 9.2 inVLQ: 6.9 indimensions:VLK: 16.65 x 3.54 x 3.66 in,option IP68: 17.44 x 3.7 x 4.13 inVLM: 12.17 x 2.24 x 2.48 inVLQ: 9.72 x 1.69 x 1.85 in

    PermaLok PL

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 25

    Technical Specification FLUXUS® G70x

    Coupling Materials for Transducers

    Technical Data

    normal temperature range(4th character of transducer order code = N)

    extended temperature range(4th character of transducer order code = E)

    < 212 °F 212 to 338 °F < 302 °F 302 to 392 °F< 2 h coupling compound

    type Ncoupling compoundtype E

    coupling compoundtype E

    coupling compoundtype E or H

    < 24 h coupling compoundtype N

    coupling compoundtype E

    coupling compoundtype E

    coupling foiltype VT

    long time measure-ment

    indoor coupling compoundtype N

    coupling compoundtype E

    coupling foiltype VT1

    coupling foiltype VT2

    outdoor coupling foiltype VT

    coupling foiltype VT

    coupling foiltype VT1

    coupling foiltype VT2

    1 < 5 years2 < 6 months

    type order code operating temperature

    material remark

    °Fcoupling compound type N

    990739-1 -22 to +266 mineral grease paste

    coupling compound type E

    990739-2 -22 to +392 silicone paste

    coupling compound type H

    990739-3 -22 to +482 fluoropolymer paste

    coupling foil type VT 990739-0 14 to 302,short-time peak max. 392

    fluoroelastomer for transducers with transducer frequency G, H, K

    990739-6 for shear wave transducers with transducer frequency M, P

    990739-14 for shear wave transducers IP68 and Lambwave transducers with transducer frequency M, P

    990739-15 for shear wave transducers with transducer frequency Q

    990739-5 for Lambwave transducers with transducer frequency Q

  • 26 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Damping Mats (optional)Damping mats will be used for the gas measurement to reduce acoustic noise influences on the measure-ment.transducer damping matTransducer damping mats will be installed below the transducers.pipe damping matPipe damping mats will be installed if the sound propagation is disturbed at reflection points (e.g. flange,weld). Depending on the noise, the pipe damping mats will be installed at one or both sides of the transducerdamping mat. If the local conditions are unknown, pipe damping mats should be installed.

    Technical Datatype E30R4 E30R3width in 8.9 2thickness in 0.03length (per roll) ft 32weight lb/ft2 2.2operating temperature °F -22 to +1760properties self-adhesive

    outer pipe diameter ≥ 35.4 in outer pipe diameter < 35.4 in

    transducer damping matpipe damping mat (optional)

    installation length

    diagonal mode/direct mode

    reflect mode

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 27

    Technical Specification FLUXUS® G70x

    Dimensioningtransducer damping mat

    transducer mounting fixture

    order code

    type number of layers

    transducer damping mat transducer damping mat+

    2x pipe damping matmax. instal-lation length number of rolls1

    max. instal-lation length number of rolls1

    [in] standard2 extended2 [in] standard extendedPermaRailVLK GLG E30R4 3 35 4 4 72 9 13

    GSG 3 4 4 9 11GLH 2 2 3 4 7GLK 1 1 1 1 2GSK 1 1 1 2 3

    VLK-**-****/IP68 GLG E30R4 3 36 5 5 75.2 10 14GSG 3 5 5 10 11GLH 2 2 3 5 7GLK 1 1 1 2 2GSK 1 1 2 2 3

    VLM GLM E30R3 1 26 1 1 53.5 1 2GSM 1 1 1 1 2GLP 1 1 1 1 1GSP 1 1 1 1 1

    VLQ GLQ E30R3 1 21.3 1 1 44.1 1 11 calculation on the base of:

    - max. installation length (installation of one transducer mounting fixture per transducer in reflect mode) and- max. recommended pipe diameter (standard) or max. extended pipe diameter (extended) (for inner pipe diameter max. recommended and max. extended see Technical Data of the Transducers from page 16)

    2 calculation for the number of rolls when both transducers are mounted in one transducer mounting fixture (reflect mode) or in diagonal mode/direct mode: number of rolls/2 and round up to the nearest integer

  • 28 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Connection Systems

    x = transducer cable lengthl = max. length of extension cable

    Transducer Cable

    Technical Data

    connection system TSconnection with extension cable direct connection transducers

    technical type****LI*

    *****52

    transducer frequency(3d character of transducer

    order code)

    G, H, K M, P Q S

    TS

    x l x l x l x lcable length ft 16 ≤ 984 13 ≤ 984 9 ≤ 295 6 ≤ 131

    cable length (option LC) ft 29 ≤ 984 - - - - - -cable length (option IP68) ft 39 ≤ 984 39 ≤ 984 - - - -

    transducer cable extension cabletype 1699 2550 6111 2615connection system TSstandard length ft see table above -max. length ft - see table aboveoperating temperature °F -67 to +392 -40 to +212 -148 to +437 -40 to +158properties longitudinal water tight halogen free

    fire propagation test according to IEC 60332-1combustion test accord-ing to IEC 60754-2

    sheathmaterial stainless steel 304 - stainless steel 304 -

    option OS: 316L option OS: 316Louter diameter in 0.31 - 0.31 -cable jacketmaterial PTFE PUR PFA PURouter diameter in 0.11 0.2 ±0.01 0.11 0.47thickness in 0.01 0.04 0.02 0.08color brown gray white blackshield x x x x

    (only G704)

    trans

    mitt

    er

    x

    l

    JBP3

    trans

    mitt

    er

    x

    trans

    mitt

    erx

    l

    JB03tra

    nsm

    itter

    x

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 29

    Technical Specification FLUXUS® G70x

    Junction Box

    Technical Data

    Dimensions

    2 " Pipe Mounting Kit (optional)

    technical type JB03 JBP3dimensions see dimensional drawing see dimensional drawingfixation wall mounting, optional: 2 " pipe mounting wall mounting, optional: 2 " pipe mountingmaterialhousing stainless steel 304

    option OS: 316Lstainless steel 316L

    gasket silicone siliconedegree of protection NEMA 6 NEMA 6operating temperaturemin. °F -40 -40max. °F +176 +176

    in inch

    6.85

    4.690.08

    wall mounting holder

    2.766.44

    6.14

    Ø 0.35

    thread: 3x M20 x 1.5cable gland: max. 2x 1/2 NPT

  • 30 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Terminal Assignment

    JB03

    JBP3

    � & � �

    � # �

    �&

    �&�

    �'

    �'

    ���

    ��

    transducersterminal connection

    XV transducer , SMB connectorXR transducer , SMB connectorcable gland external shield

    extension cableterminal strip KL2

    terminal connectionTV signalTVS internal shieldTRS internal shieldTR signalshield terminal external shield

    shield terminal

    �&

    �&�

    �'

    �'

    ���

    ��

    �&

    �&�

    ���

    ��

    � # � � # �

    transducersterminal strip KL1

    terminal connectionTV transducer , signalTVS transducer , internal shieldTRS transducer , internal shieldTR transducer , signalcable gland external shield

    extension cableterminal strip KL2

    terminal connectionTV signalTVS internal shieldTRS internal shieldTR signalshield terminal external shield

    shield terminal

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 31

    Technical Specification FLUXUS® G70x

    Clamp-on Temperature Probe (optional) Technical Datatechnical type PT13N PT13N PT13N PT13N PT13F PT13Forder code 670413-1 670412-1 770413-1 770412-1 670413-2 670412-2design with connector without connector short response timetype Pt1000 Pt1000 mat-

    ched according to EN 1434-1

    Pt1000 Pt1000 mat-ched according to EN 1434-1

    Pt1000 Pt1000 mat-ched according to EN 1434-1

    connection 4-wire 4-wire 4-wiremeasuring range °F -22 to +482 -58 to +428 -58 to +482accuracy T ±(0.27 °F + 2 . 10-3 . (T [°F] - 32 °F))

    class A±(0.27 °F + 2 . 10-3 . (T [°F] - 32 °F))

    class A±(0.27 °F + 2 . 10-3 . (T [°F] - 32 °F))

    class Aaccuracy ΔT - ≤ 0.1 K

    (3K < ΔT < 6 K), more corre-sponding to EN 1434-1

    - ≤ 0.03 °F(at 50 °F)3 point ΔT check, more cor-responding to EN 1434-1

    - ≤ 0.1 K(3K < ΔT < 6 K), more corre-sponding to EN 1434-1

    response time s 50 8housing aluminum 360 brass alloy PEEK, stainless steel 304, copperdegree of protection NEMA 4 NEMA 4 NEMA 4weight (without con-nector)

    lb 0.6 1.1 0.437 0.875 0.7 1.4

    fixation clamp-on clamp-on clamp-onaccessories - - plastic protection plate,

    insulation foamdimensionslength l in 0.59 0.59 0.55width b in 0.59 0.49 1.18height h in 0.79 0.79 1.06dimensional drawing A C B

    extension cableh

    l

    junction box

    C

    B

    h

    l

    A

    Cextension cable

    h

    l

  • 32 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    Connection

    Temperature Probe

    Connector

    Cable

    pin cable of temperature probe extension cable1 white/blue blue2 red/blue gray3, 4, 5 not connected6 red red7 white white8 not connected

    cable of temperature probe extension cabletype 4 x 0.25 mm2 black or white LIYCY 8 x 0.14 mm2 graystandard length ft 9 16/32/82max. length ft - 656cable jacket PTFE PVC

    Junction Boxtechnical type JBT3dimensions see dimensional drawingfixation wall mounting

    optional: 2 " pipe mountingmaterialhousing stainless steel 304 gasket siliconedegree of protection NEMA 6cable gland max. 2x 1/2 NPToperating temperaturemin. °F -40max. °F +176

    red/blue red white/blue whiteblack white red green

    with connectorwithout connector

    ��

  • TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05 33

    Technical Specification FLUXUS® G70x

    Terminal Assignment

    Wetted Temperature Probe (optional)

    JBT3

    � � � � � � � � � �

    � # � � # �

    temperature probe (with connector)terminal strip KL1

    terminal connection1 red2 red/blue3 white4 white/blue

    extension cable (with connector)terminal strip KL2

    terminal connection1 red2 gray3 white4 blue

    temperature probe, extension cable(without connector)terminal strip KL1, KL2

    terminal connection1 white2 black3 green4 red

    shield terminal

    type Pt1000A insertion length 6 " or specified lengthB resistance 1 000 Ω, 00385C insertion length 6 " or specified length

    sheath material stainless steel 316D thread 1/2 " NPT HEX CPLG. spring loadedE head aluminum screw cover head

    4 terminal blockF thread 3/4 " NPT

  • 34 TSFLUXUS_G7V1-5-1US_Lus, 2011-12-05

    FLUXUS® G70x Technical Specification

    FLEXIM AMERICAS CorporationEdgewood, NY 11717USATel.: (631) 492-2300Fax: (631) 492-2117

    internet: www.flexim.come-mail: [email protected]

    1-888-852-7473Subject to change without notification. Errors excepted.FLUXUS® is a registered trademark of FLEXIM GmbH.