gas valve train mki, 1” - eltronicfueltech.com filethe gvt_mki_sl is a gas valve train designed to...

2
The GVT_MkI_SL is a Gas Valve Train designed to be connected through piping from the Fuel Gas Supply (FGS) system to gas consumers such as internal combustion engines (ME-GI). The GVT is designed according to MAN Diesel & Turbo GVT requirement. The GVT is controlled by the engine control system and is a part of the following overall functionalities: Supply gas to the 2 stroke ME-GI engine Slow pressure build up and supply for engine Stop the gas supply to engine and send gas from the pipe systems and GVT to the vent header in case of normal or emergency shutdown Purging of the pipe system between the GVT and ME-GI Purging of the pipe system between the GVT and FGS System Gas Valve Train MkI, 1” Product Information

Upload: donga

Post on 06-May-2019

219 views

Category:

Documents


0 download

TRANSCRIPT

The GVT_MkI_SL is a Gas Valve Train designed to be

connected through piping from the Fuel Gas Supply (FGS)

system to gas consumers such as internal combustion engines

(ME-GI). The GVT is designed according to MAN Diesel &

Turbo GVT requirement.

The GVT is controlled by the engine control system and is a

part of the following overall functionalities:

• Supply gas to the 2 stroke ME-GI engine

• Slow pressure build up and supply for engine

• Stop the gas supply to engine and send gas from the

pipe systems and GVT to the vent header in case of

normal or emergency shutdown

• Purging of the pipe system between the GVT and ME-GI

• Purging of the pipe system between the GVT and FGS

System

Gas Valve Train MkI, 1”

Product Information

Eltronic A/S - Kilde Allé 4 - DK-8722 Hedensted - + 45 76 74 01 01 - [email protected] - www.eltronicfueltech.com

Description MkI 1” Single Line

Media Dimensioning

GVT Size Main Line: 1” (DN25)

Purge and Bleed: ½” (DN15)

Material in Contact to Media Stainless Steel

Media for the Engine Methane

Ethane

Media for Purge Nitrogen

Nominal Working Pressure for Gas Supply (PN) Up to 320 bar

Design Pressure (PS) 400 bar

Test Pressure (PT) 1,5 x design pressure

Design Flow 3500 kg/h, Methane

Media Design Temperature -25°C to +60°C

Media Temperature by Intermittent Operation -50°C to +60°C

Media Filtration

Gas Filter (GVT Safety Filter) Filter Rating: 20 µm

Nitrogen (N2) Filter Filter Rating: 20 µm

Physical Dimensions

Frame Dimensions (LxWxH) 1293 x 1105 x 1487 mm

Weight (Depending on Selected Options) Approx 1080 kg

Environment

Degree of Protection GVT (IEC 60529) Designed to be placed below deck (IP44)

Degree of Protection GVT Components (IEC 60529) IP65

Degree of Protection Elec. Cabinet (IEC 60529) IP66

Supply

Pneumatic Air 6-10 bar, dry air

Power Supply 24 VDC +20/-30%

Ex Classification

GVT Components Ex e d ia llA T1 Ga/Gb

Classification Societies (Per Customer Request) DNV/GL, LR, ABS, KR