218 GC and GC/MS www.agilent.com/chem/supplies GC, GC/MS and Duraguard Capillary Columns In 1979, Hewlett-Packard (now Agilent) revolutionized GC analysis with flexible, chemically inert fused silica GC tubing. In the same year, J&W Scientific created the first cross-linked bonded stationary phase. In 1991, J&W Scientific introduced DB-5ms, the first commercial GC stationary phase with lower column bleed using arylene technology. In 1992, Agilent released HP-5ms columns with low column bleed performance. In 2000, Agilent merged with J&W Scientific to unite the world renowned HP and DB column families under one brand – Agilent J&W GC columns. And in 2008, Agilent ushered in a new era of column inertness QC testing with the most rigorous test probe mixture in the industry. Agilent J&W GC Capillary columns are manufactured in Folsom, California. Every column is individually tested to meet the tightest quality control specifications in the industry. Our goal is to continually refine our materials and processes to provide the best columns in the world, so that each one will continue to deliver the high quality and superior performance you have come to expect. To learn more, view our video at www.agilent.com/chem/gccol5. Introducing the newest Agilent J&W GC Columns Agilent J&W Ultra Inert GC Capillary Columns Agilent J&W Ultra Inert GC Columns allow you to perform trace level analysis – including the analysis of acids, bases, or other active compounds – with the utmost confidence. What's more, Agilent has set a new industry standard for column inertness testing by introducing a new Über One Test Probe Mixture that surpasses our most stringent demands for bleed, sensitivity, and efficiency. Agilent J&W Ultra Inert GC Columns are the only GC columns that deliver on the promises of consistent column inertness performance and exceptionally low column bleed for greater sensitivity, better peak shape, and more reliable results. So you can be sure that they will meet the rigorous requirements of today's demanding applications. Agilent J&W High Efficiency GC Capillary Columns Agilent J&W High Efficiency columns are ideal for fast chromatography where speed, while maintaining resolution, is the most important attribute of the columns. The columns can be applied to any applications that require reduced analysis time, such as high throughput screening, fast process monitoring, fast QC analyses, and fast method development. High Efficiency columns are suitable for a wide variety of sample matrices, including environmental, petrochemical, flavor/fragrance, clinical toxicology, or pharmaceutical samples. Agilent J&W LTM Column Modules Agilent J&W LTM column modules combine a fused silica capillary column with heating and temperature sensing components wound around it. The design heats and cools the column very efficiently for significantly shorter analytical cycle times compared to conventional air-bath GC oven techniques, while simultaneously using less power. Agilent J&W GC and GC/MS Columns For over 40 years, Agilent has broken new ground with innovations in GC column technology.

Upload: others

Post on 19-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

218

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

GC, GC/MS and Duraguard Capillary Columns

In 1979, Hewlett-Packard (now Agilent) revolutionized GC analysis with flexible, chemicallyinert fused silica GC tubing. In the same year, J&W Scientific created the first cross-linkedbonded stationary phase. In 1991, J&W Scientific introduced DB-5ms, the first commercial GC stationary phase with lower column bleed using arylene technology. In 1992, Agilentreleased HP-5ms columns with low column bleed performance. In 2000, Agilent merged withJ&W Scientific to unite the world renowned HP and DB column families under one brand –Agilent J&W GC columns. And in 2008, Agilent ushered in a new era of column inertness QC testing with the most rigorous test probe mixture in the industry.

Agilent J&W GC Capillary columns are manufactured in Folsom, California. Every column is individually tested to meet the tightest quality control specifications in the industry. Our goalis to continually refine our materials and processes to provide the best columns in the world,so that each one will continue to deliver the high quality and superior performance you havecome to expect. To learn more, view our video at www.agilent.com/chem/gccol5.

Introducing the newest Agilent J&W GC ColumnsAgilent J&W Ultra Inert GC Capillary Columns

Agilent J&W Ultra Inert GC Columns allow you to perform trace level analysis – including the analysis of acids, bases, or other active compounds – with the utmost confidence. What'smore, Agilent has set a new industry standard for column inertness testing by introducing a new Über One Test Probe Mixture that surpasses our most stringent demands for bleed,sensitivity, and efficiency. Agilent J&W Ultra Inert GC Columns are the only GC columns thatdeliver on the promises of consistent column inertness performance and exceptionally lowcolumn bleed for greater sensitivity, better peak shape, and more reliable results. So you canbe sure that they will meet the rigorous requirements of today's demanding applications.

Agilent J&W High Efficiency GC Capillary Columns

Agilent J&W High Efficiency columns are ideal for fast chromatography where speed, while maintaining resolution, is the most important attribute of the columns. The columns can be applied to any applications that require reduced analysis time, such as high throughputscreening, fast process monitoring, fast QC analyses, and fast method development. High Efficiency columns are suitable for a wide variety of sample matrices, includingenvironmental, petrochemical, flavor/fragrance, clinical toxicology, or pharmaceutical samples.

Agilent J&W LTM Column Modules

Agilent J&W LTM column modules combine a fused silica capillary column with heating and temperature sensing components wound around it. The design heats and cools thecolumn very efficiently for significantly shorter analytical cycle times compared to conventionalair-bath GC oven techniques, while simultaneously using less power.

Agilent J&W GC and GC/MS Columns

For over 40 years, Agilent has broken new ground with innovations in GC column technology.

Page 2: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

219

GC and GC/MS

www.agilent.com/chem/supplies

Agilent J&W GC and GC/MS Columns

The Industry's Best Low-Bleed and Most Inert ColumnsColumn bleed can decrease spectral integrity, reduce uptime, and shorten column life. Columnactivity contributes to severe peak tailing, as well as compound loss or degradation for activecompounds (e.g. acids and bases), leading to inaccurate quantification. Agilent J&W columnshave the widest range of GC/MS and Ultra Inert stationary phases proven to deliver consistentcolumn inertness and exceptionally low column bleed with high upper temperature limits,ensuring accurate peak identification and quantification.

Why low-bleed columns are a smart choice

If you perform trace analyses where sensitivity and instrument performance are important,column bleed (or the lack thereof) should be important to you. Many GC detectors aresensitive to contamination from bleed. By using low-bleed columns, these detectors requireless maintenance. Due to the unique relationship between ion storage capacity of the trapand sensitivity levels, ion trap MS users will especially benefit from low-bleed columns.

What makes Agilent J&W low-bleed columns so special?

In short, it's Agilent’s unique polymer chemistry and proprietary deactivation. Our MS columns utilize special surface deactivation and siloxane chemistries that enhance thechromatographic performance of siloxane polymers. To provide selectivities virtually identicalto their conventional counterparts, we offer DB-5ms, DB-35ms, DB-17ms, and DB-225ms.The HP-5ms uses the same stationary phase as the standard HP-5, providing low bleedwithout the use of arylene technology. DB-1ms and HP-1ms provide the same selectivity as the standard 100% dimethylpolysiloxane (DB-1) type column. Plus, our unique DB-1mspolymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability and optimizing performance.

Always Quality.

Always Innovative.

Always Agilent.

Tips & Tools

Agilent offers GC Column Accessories, including installation kits, rinse kits,fused silica tubing cutters, and column baskets.

Turn to page 108.

Page 3: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

220

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Tighter GC Column Performance Criteria

Feature Advantage Benefit

Narrow Retention Index and Retention Factor Window

� Highest level of column-to-columnreproducibility

� Confidence in analytical results

� Minimal method adjustment whenchanging columns

� Specify J&W chemistry for intra-companymethodologies

� Confidence in method transfer and intra-company results

Increased Plates per Meter � Highest level of "resolving power"� Improved sample throughput

� Accurate quantification� Potentially shorter run times

Lowest Bleed � Increased analytical sensitivity for all detectors

� Improved detection limits� Reliable compound identification

� Fast baseline stabilization� Faster column exchange

� Minimized conditioning time� Increased sample throughput

� Excellent thermal stability � Increased column lifetime, reduced downtime

� Increased sample throughput

Highest Degree of Inertness � Better peak shape for active compounds� Minimum compound adsorption

� Improved detection limit, more accurate quantification, and moreinstrument uptime

� More accurate quantification for tracesamples and unknown sample screening

The Tightest QC Specs in the Business Agilent makes more capillary GC columns than anyone else in the world, and we build them to meet consistently rigid performance criteria,such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.

Agilent's stringent QC performance evaluation tests provide the utmost confidence in the qualitative and quantitative results, especiallyfor difficult-to-chromatograph compounds. We measure peak height ratios for acidic and basic compounds to ensure the highest columnperformance for the widest range and types of compounds. We also carefully monitor peak symmetry and tailing for a broad range ofchemically active compounds.

For additional column recommendations, chromatograms, and methodparameters, visit www.agilent.com/chem/mygccol1

Agilent J&W GC and GC/MS Columns

� Improved sample throughput, reduced downtime

Tips & Tools

Page 4: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

221

GC and GC/MS

www.agilent.com/chem/supplies

Agilent J&W GC and GC/MS Columns

Choosing a Capillary GC Column

The first step should always be to refer to what has already been done. Our chemists have put together a variety of resources to help you find the right column for your analysis.

• Chromatograms – Find some of the more common chromatograms with columnrecommendations and method parameters for your reference in this catalog. For a more extensive chromatogram library and a compound search function, go to www.agilent.com/chem, then click Library.

• Method Guides – We’ve evaluated the most common Environmental/EPA methods, ASTM methods, USP methods and general compound analyses and have put togethersimple guides which specify the best column recommendation for these methods.

• Retention Data Lists – We've analyzed hundreds of compounds on several different phasesto help you determine which column will be the best choice for your list of compounds.

• Column Selection Guide – Our Agilent J&W GC Column Selection Guide gives you helpfulhints for choosing a stationary phase, picking the right column dimensions, developingtemperature programs and determining the right inlet and detector for the application. To order this guide, use publication number 5989-6159EN.

Our Technical Support Chemists have more than 100 years of combined experience runningsamples and developing methods. We are the gas chromatography column experts and weare at your disposal.

Send in questions on the Technical Support question form on our websitewww.agilent.com/chem, via email at [email protected], or contact yourlocal Agilent office or Authorized Agilent Distributor.Tips & Tools

See where quality begins. Take a virtual tour of our GC columnmanufacturing site atwww.agilent.com/chem/gccol5.

Page 5: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

222

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Ultra Inert Capillary GC Columns

Agilent J&W Ultra Inert Capillary GC Columns

• Individually tested with a unique, demanding Über One test probe mixture

• Consistent column inertness performance

• Exceptionally low column bleed

• Great peak shapes for challenging active analytes

• Excellent signal-to-noise ratios

• Minimum compound adsorption or degradation

• Support of 0.18 mm ID column configuration for higher sample throughput

Ultra Inert Chromatograms

Environmental

Trace Level PolycyclicAromatic Hydrocarbon(PAH) Analyses

Page 374

US EPA Method 8270 Short Mix

Page 373

Life Sciences

Benzodiazepines I Page 447

Ultra Inert Capillary GC Columns

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-5ms Ultra Inert

0.18 20 0.18 -60 to 325/350 121-5522UI

0.36 -60 to 325/350 121-5523UI

0.25 15 0.25 -60 to 325/350 122-5512UI

1.0 -60 to 325/350 122-5513UI

25 0.25 -60 to 325/350 122-5522UI

30 0.25 -60 to 325/350 122-5532UI

0.50 -60 to 325/350 122-5536UI

1.0 -60 to 325/350 122-5533UI

50 0.25 -60 to 325/350 122-5552UI

60 0.25 -60 to 325/350 122-5562UI

1.0 -60 to 325/350 122-5563UI

0.32 30 0.25 -60 to 325/350 123-5532UI

0.50 -60 to 325/350 123-5536UI

1.0 -60 to 325/350 123-5533UI

60 1.0 -60 to 325/350 123-5563UI

HP-5ms Ultra Inert

0.18 20 0.18 -60 to 325/350 19091S-577UI

0.25 15 0.25 -60 to 325/350 19091S-431UI

30 0.25 -60 to 325/350 19091S-433UI

0.50 -60 to 325/350 19091S-133UI

1.0 -60 to 325/350 19091S-233UI

60 0.25 -60 to 325/350 19091S-436UI

0.32 30 0.25 -60 to 325/350 19091S-413UI

1.0 -60 to 325/350 19091S-213UI

NEW!

Page 6: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

223

GC and GC/MS

www.agilent.com/chem/supplies

Ultra Inert Capillary GC Columns

Agilent's Über One Test Probe MixtureColumn: DB-5ms Ultra Inert

122-5532UI30 m x 0.25 mm, 0.25 µmAgilent 6890N

Carrier: Hydrogen, constant pressure, 38 cm/s

Oven: 65°C isothermal

Sampler: Agilent 7683B, 0.5 µL syringe(Agilent Part No. 5188-5246), 0.02 µL split injection

Injection: Split/splitless; 250°C, 1.4 mL/min; split column flow900 ml/min; gas saver flow 75 mL/min at 2.0 min

Detector: FID at 325°C; 450 mL/min air, 40 mL/min hydrogen,45 mL/min nitrogen makeup

1

23

4

5

6

7

8

9

1011

DB5msPeaksTime (min)

0 2 6 8 104

10

12.5

15

17.5

20

22.5

25

27.5

pA

30

1. 1-Propionic acid

2. 1-Octene

3. n-Octane

4. 4-Picoline

5. n-Nonane

6. Trimethyl phosphate

7. 1,2-Pentanediol

8. n-Propylbenzene

9. 1-Heptanol

10. 3-Octanone

11. n-Decane

A properly deactivated DB-5ms Ultra Inert Column delivers symmetrical peak shapes, along with increasedpeak heights, which allow for accurate integration and detection of trace analytes.

Page 7: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

224

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Agilent J&W High Efficiency Capillary GC Columns

• Increase sample throughput and productivity while maintaining resolution

• Reduce carrier gas usage and cost per analysis

• Compatible with existing GC and GC/MS instrument

• Operates with He or H2 carrier gas

• Available in more than 20 stationary phases

• Rapid and easy method translation with Agilent Method Translation Software

High Efficiency Capillary GC Columns

Phase ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-1 0.18 10 0.18 -60 to 325/350 121-1012

0.20 -60 to 325/350 121-101A

0.40 -60 to 325/350 121-1013

20 0.18 -60 to 325/350 121-1022

0.40 -60 to 325/350 121-1023

40 0.40 -60 to 325/350 121-1043

HP-1 0.18 20 0.18 -60 to 325/350 19091Z-577

DB-1ms 0.18 20 0.18 -60 to 340/360 121-0122

HP-1ms 0.18 20 0.18 -60 to 325/350 19091S-677

DB-5 0.18 10 0.18 -60 to 325/350 121-5012

0.40 -60 to 325/350 121-5013

20 0.18 -60 to 325/350 121-5022

0.40 -60 to 325/350 121-5023

40 0.18 -60 to 325/350 121-5042

HP-5 0.18 20 0.18 -60 to 325/350 19091J-577

DB-5ms 0.18 20 0.18 -60 to 325/350 121-5522

0.36 -60 to 325/350 121-5523

40 0.18 -60 to 325/350 121-5542

High Efficiency Capillary GC Columns

High Efficiency Chromatograms

Environmental

Analysis of Semivolatiles Page 373

CLP Pesticide Analysis Page 361

Petroleum

Fast Analysis of AromaticSolvent

Page 464

NEW!

Page 8: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

225

GC and GC/MS

www.agilent.com/chem/supplies

High Efficiency Capillary GC Columns

HP-5ms 0.18 20 0.18 -60 to 325/350 19091S-577

DB-XLB 0.18 20 0.18 30 to 340/360 121-1222

30 0.18 30 to 340/360 121-1232

DB-35ms 0.18 20 0.18 50 to 340/360 121-3822

DB-17 0.18 20 0.18 40 to 280/300 121-1722

0.30 40 to 280/300 121-1723

DB-17ms 0.18 20 0.18 40 to 320/340 121-4722

HP-50+ 0.18 20 0.18 40 to 280/300 19091L-577

DB-23 0.18 20 0.20 40 to 250/260 121-2323

DB-225 0.18 20 0.20 40 to 220/240 121-2223

DB-624 0.18 20 1.00 -20 to 280 121-1324

DB-1301 0.18 10 0.40 -20 to 280/300 121-1313

DB-1701 0.18 10 0.40 -20 to 280/300 121-0713

20 0.18 -20 to 280/300 121-0722

DB-WAX 0.18 10 0.18 20 to 250/260 121-7012

20 0.18 20 to 250/260 121-7022

40 0.18 20 to 250/260 121-7042

0.30 20 to 240/250 121-7043

HP-INNOWax 0.18 20 0.18 40 to 260/270 19091N-577

DB-5.625 0.18 20 0.18 -60 to 325/350 121-5621

0.36 -60 to 325/350 121-5622

DB-VRX 0.18 20 1.00 -10 to 260 121-1524

40 1.00 -10 to 260 121-1544

DB-608 0.18 20 0.18 40 to 280/300 121-6822

Phase ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

High Efficiency Capillary GC Columns

Page 9: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

226

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

High Efficiency Capillary GC Columns

Direct Column-Performance Comparison for Rapid CLP (Contract Laboratory Program) Pesticide Analysis

Column: DB-17ms121-472220 m x 0.18 mm,0.18 µm

Column: DB-XLB121-122220 m x 0.18 mm,0.18 µm

Carrier: Hydrogen (69 cm/sec at 120% C, ramped at 99 mL/min to 106 cm/sec at 4.4 minutes)

Oven: 120% C (0.32 min); 120% C/min to 160% C; 30% C/min to258% C (0.18 min); 38.81% C/min to 300% C (1.5 min)

Injection: Split/splitless; 220% C, pulsed splitless (35 psi for 0.5 min, purge flow of 40 mL/min on at 1 minute, gas saver flow 20 ml/min on 3 minutes)

Detector: µECD 320% C; nitrogen makeup; constant column + makeup flow 60 mL/min

Time (min)

12 3

456 7 8 9

10

11

12 13

14

15

16

1718

19

20

21

22

GCHE004

21100125

175150

200225250275300Hz

3 4 5 6

Time (min)

21

150

200

250

300

350

400

Hz

3 4 5 6

1

2 34

56 7 8

9

10

11

121314

15

161718

19

20

21

22

Time (min)

GCHE005

21100

150

200

250

300

350

400

450Hz

3 4 5 6

Time (min)

21200

300

400

500

600

700

Hz

3 4 5 6

DB-17ms primary column

DB-XLB confirmatory column

1. Tetrachloro-m-xylene

2. Alpha BHC

3. Gamma BHC

4.

5. Delta BHC

6. Heptachlor

7. Aldrin

8. Heptachlor Epoxide

9. Gamma Chlordane

Beta BHC

Co-elution

Co-elution

Peak tailing

Baseline rise

Peak tailing

Baseline rise

10. Alpha Chlordane

11. Endosulfan I

12. 4,4' DDE

13. Dieldrin

14. Endrin

15. 4,4' DDD

16. Endosulfan II

17. 4,4' DDT

18. Endrin Aldehyde

19. Endosulfan Sulfate

20. Methoxychlor

21. Endrin Ketone

22. Decachlorobiphenyl

Vendor R primary column, 20 m x 0.18 mm, 0.18 µm

Vendor R confirmatory column, 20 m x 0.18 mm, 0.14 µm

Agilent's DB-17ms primary column and DB-XLB confirmatory column sufficiently resolved all the peaks of interest in less than 6 minutes with sharp, symmetrical peaksand minimal baseline drift. In contrast, vendor R's primary analysis column resolved only 20 of 22 peaks with visible peak tailing. Vendor R's confirmatory column resolvedall 22 peaks of interest but with peak tailing and an unacceptable level of temperature dependent baseline drift.

Page 10: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

227

GC and GC/MS

www.agilent.com/chem/supplies

High Efficiency Capillary GC Columns

Spearmint Oil

Carrier: A: Helium 25 cm/sec measured at 40°CB: Hydrogen 47 cm/sec measured at 40°C

Oven: A: 40°C hold 1 min, 5°C/min to 290°CB: 40°C hold 0.38 min, 13°C/min to 290°C hold 13.09 min

Injection: 250°C, Split 40:1, 1-µL injection

Original Method with a DB-1, 30 m x 0.25 mm x 0.25 µmcolumn and Helium carrier

Faster Method with a high efficiency DB-1, 20 m x 0.1 8mm x 0.18 µm column and Hydrogen carrier

1.

2. Sabinene

3.

4. 3-Octanol

5. Myrcene

6.

7. ρ-Cymene

8. 1,8-Cineol

9. Limonene

10. cis-Ocimene

11. trans-Ocimene

12.

13. trans-Sabinene hydrate

14. Terpinolene

Column A: DB-1122-103230 m x 0.25 mm, 0.25 µm

Column B: DB-1121-102220 m x 0.18 mm, 0.18 µm

Using hydrogen as a carrier gas in conjunction with the high efficiency column resulted in an overall speed gain of 61% compared to the the original method. In addition, the resolution was well maintained throughout the method translation process.

15. Linalool

16. 3-Octyl acetate

17. Isomenthone

18. Terpinen-4-ol

19. Dihydrocarvone

20. trans-Carveol

21. l-Carvone

22. trans-Dihydrocarveol acetate

23. cis-Carvyl acetate

24. cis-Jasmone

25.

26.

27.

28.

29. trans-b-Farnesene

30. Germacrene-d

31. Viridiflorol

SPEARMINTbTime (min)

B

3 5 7 9 11

1819

20

21

22 23

26

27

2829

30

3124

25

1716

1514

1

23 4

5

6 7

9

1011

13

12

8

1 23

4

5

67

8

9

1011

12

13

14 1516

17

18

19

20

21

22

23

24

25

26

27

28

2930

31

8 10 12 14 16 18 20 22 24 26 28Time (min)

A

SPEARMINTa

Page 11: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

228

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Columns for GC/MS

There is a rapidly increasing population of benchtop GC/MS instruments in analyticallaboratories that analyze a broadening range of trace level, higher temperature samples.These samples require increasingly inert, lower bleed, higher temperature columns. Inresponse to this growing need, Agilent Technologies deliberately designed several "ms"columns to chromatograph a broader range of low level samples and generate lower bleedeven at higher temperatures.

Unique polymer chemistry and proprietary surface deactivation, both of which havecontributed to columns that adhere to the tightest quality control specifications in the industryfor bleed, inertness, selectivity and efficiency. Agilent J&W "ms" columns utilize specialsurface deactivation and siloxane chemistries which enhance the chromatographicperformance of siloxane polymers.

The mass spectrum of septum bleed can look very much like GC column bleed, so the two areoften confused. An easy way to tell the two apart: column bleed will be a rise in the baseline,not peaks. If you see bleed peaks, these generally come from lower quality septa or septabeing used beyond their operating limits. To minimize septa contributions to background bleeduse quality Agilent BTO, Long Life, or Advanced Green septa.

Columns for GC/MS

While some of the GC/MS phases utilize different polymer chemistries, their selectivity mimicsthe standard polysiloxane phases and offers the advantages of low column bleed and, in somecases, extended temperature ranges.

What makes an Agilent J&W low bleed column unique?

Tips & Tools

Agilent MS Certified Liners are lot-tested with MSD and FID for superior acid/basedeactivation, response linearityand peak symmetry.

Turn to page 153.

Page 12: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

229

GC and GC/MS

www.agilent.com/chem/supplies

Structure of Dimethylpolysiloxane

• 100% Dimethylpolysiloxane, identical selectivity to DB-1

• Non-polar

• Very low bleed characteristics, ideal for GC/MS

• Improved acid performance compared to standard 100% Dimethylpolysiloxane columns

• Improved signal-to-noise ratio for better sensitivity and mass spectral integrity

• 340/360°C upper temperature limit

• Excellent general purpose column

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: HP-1ms, Rtx-1ms, Rxi-1ms, VF-1ms, CP-Sil 5 CB Low Bleed/MS, MDN-1, AT-1, ZB-1ms, Equity-1

DB-1ms Chromatograms

Life Sciences

Drug Screen Page 449

DB-1ms

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 10 0.10 -60 to 340/360 127-0112

0.40 -60 to 340/360 127-0113

20 0.10 -60 to 340/360 127-0122

0.40 -60 to 340/360 127-0123

0.18 20 0.18 -60 to 340/360 121-0122

0.20 12 0.33 -60 to 340/350 128-0112

25 0.33 -60 to 340/350 128-0122

0.25 15 0.25 -60 to 340/360 122-0112

30 0.10 -60 to 340/360 122-0131

0.25 -60 to 340/360 122-0132

60 0.25 -60 to 340/360 122-0162

0.32 15 0.25 -60 to 340/360 123-0112

30 0.10 -60 to 340/360 123-0131

0.25 -60 to 340/360 123-0132

60 0.25 -60 to 340/360 123-0162

Columns for GC/MS

DB-1ms

O Si

100%CH3

CH3

Page 13: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

230

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Structure of Dimethylpolysiloxane

• 100% Dimethylpolysiloxane

• Identical selectivity to HP-1

• Non-polar

• Low bleed characteristics

• Excellent general purpose column

• Improved signal-to-noise ratio for better sensitivity and mass spectral integrity

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: DB-1ms, Rtx-1ms, Rxi-1ms, VF-1ms, CP-Sil 5 CB Low Bleed/MS, MDN-1, AT-1, ZB-1ms, Equity-1

HP-1ms

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091S-677

0.20 25 0.33 -60 to 325/350 19091S-602

0.25 15 0.25 -60 to 325/350 19091S-931

30 0.10 -60 to 325/350 19091S-833

0.25 -60 to 325/350 19091S-933

0.50 -60 to 325/350 19091S-633

1.00 -60 to 325/350 19091S-733

60 0.25 -60 to 325/350 19091S-936

0.32 15 0.25 -60 to 325/350 19091S-911

25 0.52 -60 to 325/350 19091S-612

30 0.25 -60 to 325/350 19091S-913

1.00 -60 to 325/350 19091S-713

60 0.25 -60 to 325/350 19091S-916

Columns for GC/MS

HP-1ms

HP-1ms Chromatograms

Environmental

Nitrogen ContainingHerbicides(EPA Method 507)

Page 372

O Si

100%CH3

CH3

Page 14: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

231

GC and GC/MS

www.agilent.com/chem/supplies

Structure of Poly(dimethylsiloxy)poly(1,4-bix(dimethylsiloxy)phenylen)siloxane

• Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane

• Non-polar

• Very low bleed characteristics, ideal for GC/MS

• Excellent inertness for active compounds

• Improved signal-to-noise ratio for better sensitivity and mass spectral integrity

• Bonded and cross-linked

• Solvent rinsable

• MSD testing and certification available

• Exact replacement of HP-5TA

• Close equivalent to USP Phase G27

• Test mix available

Similar Phases: Rtx-5ms, Rtx-5Sil MS, Rxi-5ms, Rxi-5Sil MS, VF-5ms, PTE-5, CP-Sil 8 CB Low Bleed/MS, BPX-5, AT-5ms, ZB-5ms, SLB-5ms, Equity-5

Columns for GC/MS

CH3

O OSi SiSi

m nCH3 CH3 CH3

CH3 CH3

DB-5ms

DB-5ms

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 121-5522

0.36 -60 to 325/350 121-5523

40 0.18 -60 to 325/350 121-5542

0.20 12 0.33 -60 to 325/350 128-5512

25 0.33 -60 to 325/350 128-5522

50 0.33 -60 to 325/350 128-5552

DB-5ms Chromatograms

Environmental

Diesel Fuel Page 360

EPA Air Analysis Method TO-15 (1 ppbV Standard)

Page 393

EPA Method 525.2 Page 382

EPA Method 8061 (Phthalate Esters)

Page 383

Formaldehyde, 50ppb Page 394

Organochlorine Pesticides IIEPA Method 8081A

Page 363

OrganophosphorousPesticides I, EPA Method 8141A

Page 369

Phenols Page 385

Sulfur in Air Page 394

Industrial Chemicals

Amines and Nitriles Page 421

Phenols II Page 443

Polyethyleneamines Page 420

Substituted Anilines Page 442

Life Sciences

Narcotics Page 456

Page 15: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

232

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Columns for GC/MS

0.25 15 0.10 -60 to 325/350 122-5511

0.25 -60 to 325/350 122-5512

0.50 -60 to 325/350 122-5516

1.00 -60 to 325/350 122-5513

25 0.25 -60 to 325/350 122-5522

0.40 -60 to 325/350 122-552A

30 0.10 -60 to 325/350 122-5531

0.25 -60 to 325/350 122-5532

0.50 -60 to 325/350 122-5536

1.00 -60 to 325/350 122-5533

50 0.25 -60 to 325/350 122-5552

60 0.10 -60 to 325/350 122-5561

0.25 -60 to 325/350 122-5562

1.00 -60 to 325/350 122-5563

0.32 15 0.10 -60 to 325/350 123-5511

0.25 -60 to 325/350 123-5512

1.00 -60 to 325/350 123-5513

25 0.52 -60 to 325/350 123-5526

30 0.10 -60 to 325/350 123-5531

0.25 -60 to 325/350 123-5532

0.50 -60 to 325/350 123-5536

1.00 -60 to 325/350 123-5533

60 0.10 -60 to 325/350 123-5561

0.25 -60 to 325/350 123-5562

0.50 -60 to 325/350 123-5566

1.00 -60 to 325/350 123-5563

0.53 15 1.50 -60 to 300/320 125-5512

30 0.50 -60 to 300/320 125-5537

1.00 -60 to 300/320 125-553J

1.50 -60 to 300/320 125-5532

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-5ms

Page 16: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

233

GC and GC/MS

www.agilent.com/chem/supplies

Structure of Diphenyldimethylpolysiloxane

• (5%-Phenyl)-methylpolysiloxane

• Identical selectivity to HP-5

• Non-polar

• Very low bleed characteristics, ideal for GC/MS

• Excellent inertness for active compounds including acidic and basic compounds

• Improved signal-to-noise ratio for better sensitivity and mass spectral integrity

• Bonded and cross-linked

• Solvent rinsable

• Equivalent to USP Phase G27

Similar Phases: Rtx-5MS, Rtx-5 Amine, DB-5ms, PTE-5, CP-Sil 8CB Low Bleed/MS, BPX-5, ZB-5ms

HP-5ms Chromatograms

Environmental

Chlorinated Pesticides, EPA Method 508

Page 365

Nitrogen/PhosphorusContaining Pesticides, EPA Method 507

Page 369

Organohalide Pesticides in Water, EPA Method 505

Page 365

Semivolatile Compounds, EPA Method 8270

Page 375

Food, Flavors and Fragrances

Fragrance Allergens Page 397

Industrial Chemicals

Trace Active Amines, 10 ng on-column

Page 419

Phenols I Page 443

HP-5ms

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091S-577

0.20 12 0.33 -60 to 325/350 19091S-101

25 0.33 -60 to 325/350 19091S-102

50 0.33 -60 to 325/350 19091S-105

0.25 15 0.10 -60 to 325/350 19091S-331

0.25 -60 to 325/350 19091S-431

1.00 -60 to 325/350 19091S-231

30 0.10 -60 to 325/350 19091S-333

0.25 -60 to 325/350 19091S-433

0.50 -60 to 325/350 19091S-133

1.00 -60 to 325/350 19091S-233

60 0.10 -60 to 325/350 19091S-336

0.25 -60 to 325/350 19091S-436

0.32 25 0.52 -60 to 325/350 19091S-112

30 0.10 -60 to 325/350 19091S-313

0.25 -60 to 325/350 19091S-413

0.50 -60 to 325/350 19091S-113

1.00 -60 to 325/350 19091S-213

60 0.25 -60 to 325/350 19091S-416

Columns for GC/MS

HP-5ms

O Si

CH3

CH3

O Si

CH6H5

CH6H5 5%95%

Page 17: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

234

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• EXceptionally Low Bleed

• Low polarity

• Extended temperature limit of 340/360°C

• Unique selectivity

• Excellent inertness for active compounds

• Ideal for confirmational analyses

• Excellent for pesticides, herbicides, PCBs and PAHs

• Ideal for GC/MS

• MSD testing and certification available

• Bonded and cross-linked

• Solvent rinsable

Note: "DB-XLB is designed for inhibiting column bleed at high temperatures. It also appears tohave inadvertently inherited an exceptional ability for separating many PCB congeners whenused with MS detection. This stellar performance was maximized after careful optimization ofthe column dimensions, temperature programs, and carrier gas flow conditions."(Frame, G. Analytical Chemistry News & Features, Aug. 1, 1997, 468A-475A)

Similar Phases: Rtx-XLB, MDN-12

DB-XLB Chromatograms

Environmental

Aroclors 1016-1268 (without 1221)

Page 377

CLP Pesticides Page 362

CLP Pesticide Analysis Page 361

Congeners in DIN MethodPCBs

Page 378

EPA Method 552.2 Page 386

Herbicides I Page 370

PBDEs Page 377

PCBs by EPA Method 8082 Page 379

Pesticides, EPA 508.1 Page 364

Phenols Page 385

Phenoxy Acid Herbicides - Methyl Derivatives, EPA8151A

Page 372

Food, Flavors and Fragrances

Ylang Ylang Oil Page 404

DB-XLB

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 30 to 340/360 121-1222

30 0.18 30 to 340/360 121-1232

0.20 12 0.33 30 to 340/360 128-1212

25 0.33 30 to 340/360 128-1222

0.25 15 0.10 30 to 340/360 122-1211

0.25 30 to 340/360 122-1212

30 0.10 30 to 340/360 122-1231

0.25 30 to 340/360 122-1232

0.50 30 to 340/360 122-1236

1.00 30 to 340/360 122-1233

60 0.25 30 to 340/360 122-1262

0.32 30 0.25 30 to 340/360 123-1232

0.50 30 to 340/360 123-1236

60 0.25 30 to 340/360 123-1262

0.53 15 1.50 30 to 320/340 125-1212

30 1.50 30 to 320/340 125-1232

Columns for GC/MS

DB-XLB

Page 18: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

235

GC and GC/MS

www.agilent.com/chem/supplies

• Virtually equivalent to a (35%-Phenyl)-methylpolysiloxane

• Mid-polarity

• Very low bleed characteristics, ideal for GC/MS

• Extended temperature limit of 340/360°C

• Excellent inertness for active compounds

• Ideal for confirmational analyses

• Bonded and cross-linked

• Solvent rinsable

• Replaces HP-35ms

• Close equivalent to USP Phase G42

Similar Phases: Rtx-35, Rtx-35ms, VF-35ms, SPB-35, AT-35, Sup-Herb, MDN-35, BPX-35

DB-35ms Chromatograms

Environmental

CLP Pesticides Page 362

EPA Method 552.2 Page 386

Organochlorine Pesticides I EPA Method 8081A

Page 363

OrganophosphorousPesticides I, EPA Method 8141A

Page 369

PCBs by EPA Method 8082 Page 379

Pesticides, EPA 508.1 Page 364

Phenoxy Acid Herbicides - Methyl Derivatives, EPA 8151A

Page 372

Industrial Chemicals

Anilines Page 442

Life Sciences

Barbiturates Page 453

Benzodiazepines II Page 453

DB-35ms

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 50 to 340/360 121-3822

0.20 15 0.33 50 to 340/360 128-3812

25 0.33 50 to 340/360 128-3822

0.25 15 0.25 50 to 340/360 122-3812

30 0.15 50 to 340/360 122-3831

0.25 50 to 340/360 122-3832

60 0.25 50 to 340/360 122-3862

0.32 15 0.25 50 to 340/360 123-3812

30 0.25 50 to 340/360 123-3832

0.53 30 0.50 50 to 320/340 125-3837

1.00 50 to 320/340 125-3832

Columns for GC/MS

DB-35ms

Structure of Poly(dimethylsiloxy)poly(1,4-bix(dimethylsiloxy)phenylen)siloxane

CH3

O OSi SiSi

m nCH3 CH3 CH3

CH3 CH3

Page 19: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

236

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• Virtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane

• Mid/high polarity

• Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs)

• Low bleed

• Bonded and cross-linked

• Solvent rinsable

• Close equivalent to USP Phase G7

Similar Phases: HP-225, SP-2330, CP-Sil 43 CB, Rtx-225, BP-225, OV-225, 007-225, AT-225

DB-225ms Chromatograms

Environmental

Tetrachlorodibenzo-p-furans Page 374

Food, Flavors and Fragrances

FAMEs II Page 410

DB-225ms

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.25 40 to 240 122-2912

30 0.25 40 to 240 122-2932

60 0.25 40 to 240 122-2962

0.32 30 0.25 40 to 240 123-2932

DB-225ms

• Virtually equivalent to (50%-Phenyl)-methylpolysiloxane

• 320/340°C upper temperature limit

• Very low bleed mid-polarity column, ideal for GC/MS

• Excellent inertness for active compounds

• Enhanced mass spectral integrity

• Bonded and cross-linked

• Solvent rinsable

• Best column for CLP pesticides

Similar Phases: HP-50+, Rtx-50, VF-17ms, 007-17, SP-2250, SPB-50, BPX-50, SPB-17, AT-50DB-17ms Chromatograms

Environmental

Dioxins and Furans Page 376

PAHs Page 384

Life Sciences

Hallucinogens Page 455

Tocopherols Page 454

DB-17ms

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 40 to 320/340 121-4722

0.25 15 0.15 40 to 320/340 122-4711

0.25 40 to 320/340 122-4712

30 0.15 40 to 320/340 122-4731

0.25 40 to 320/340 122-4732

60 0.25 40 to 320/340 122-4762

0.32 15 0.25 40 to 320/340 123-4712

30 0.25 40 to 320/340 123-4732

Columns for GC/MS

DB-17ms

O OSi

CH3

CH3

Si Si

CH3

CH3

CH3

CH3

m n

Structure of Poly(dimethylsiloxy)poly(1,4-bix(dimethylsiloxy)phenylen)siloxane

Page 20: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

237

GC and GC/MS

www.agilent.com/chem/supplies

Columns for GC/MS

• Columns with "built in" guard columns, no press-fit connectors

• Minimize front-end contamination and increase column lifetime

• Aid in focusing sample onto the front of the column for better peak shape

• Minimize MSD contamination originating from the column (when used in transfer line)

DuraGuard columns of different phases and dimensions are available through AgilentTechnologies' custom column shop. Any DB polysiloxane or GC/MS phase can be made as a DuraGuard column with 0.18 mm ID or larger fused silica tubing. Ask for a customcolumn quote (part number 100-2000 and specify the phase, ID, length, and film thickness of analytical column, and desired length of DuraGuard).

DuraGuard

Phase ID (mm) Length (m) Film (µm)DRGDLength (m) Part No.

DB-1 0.25 30 0.25 10 122-1032G

DB-XLB 0.25 30 0.25 10 122-1232G

DB-5ms 0.25 30 0.25 10 122-5532G

30 0.50 10 122-5536G

60 0.25 10 122-5562G

30 1.00 10 122-5533G

0.32 30 1.00 10 123-5533G

0.53 30 0.50 10 125-5537G

DB-5.625 0.18 20 0.36 5 121-5622G5

0.25 30 0.25 5 122-5631G5

DB-1701 0.53 30 1.00 10 125-0732G

DB-624 0.53 30 3.00 5 125-1334G5

DuraGuard

Tips & Tools

Column contamination from sample matrix components is the number onecause of column failure. Use Agilent DuraGuard GC columns with built-in guardif you do not want to use column connectors.

Page 21: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

238

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Polysiloxanes are the most common stationary phases. They are available in the greatestvariety and are stable, robust and versatile. Standard polysiloxanes are characterized by the repeating siloxane backbone. Each silicon atom contains two functional groups. The typeand amount of the groups distinguish each stationary phase and its properties.

With the merger of Agilent and J&W Scientific there were many similar columns with the same type of polymer. In some cases the manufacturing and QC processes were exactlythe same. In these cases the DB version was kept. In the cases where the HP and the DBcolumns had any manufacturing or QC differences, we opted to keep both phases available as in the case of DB-1 and HP-1. Each of these columns is a high quality product made tomeet exacting quality control testing. However, there may be some subtle performancedifferences. For example the DB-35 and the HP-35 have slightly different selectivities.Therefore, we are still offering both the DB and the HP version for our customers who have methods already developed on these columns.

Polysiloxane Polymers Columns

Polysiloxane Polymers Columns

Page 22: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

239

GC and GC/MS

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

Structure of Dimethylpolysiloxane

• 100% Dimethylpolysiloxane

• Non-polar

• Excellent general purpose column

• Wide range of applications

• Low bleed

• High temperature limit

• Bonded and cross-linked

• Solvent rinsable

• Wide range of column dimensions available

• Equivalent to USP Phase G2

Similar Phases: HP-1, Ultra-1, SPB-1, CP-Sil 5 CB Low Bleed/MS, Rtx-1, BP-1, OV-1, OV-101,007-1(MS), SP-2100, SE-30, CP-Sil 5 CB MS, ZB-1, AT-1, MDN-1, ZB-1

DB-1 Chromatograms

Environmental

EPA Air AnalysisCompendium Method TO-14 Standard

Page 392

EPA Method 551 Page 391

Pyrethrins Page 380

Food, Flavors and Fragrances

Fragrance ReferenceStandard I

Page 398

Spearmint Oil Page 227

Industrial Chemicals

Aldehydes and Ketones Page 423

Aromatics in FinishedGasoline- ASTM Method 5769

Page 482

Esters I Page 429

PFBHA Derivative Page 425

Glycols III Page 432

Halogenated Hydrocarbons II Page 435

Nitrogen Based Solvents I Page 439

Triethylene Glycol and Impurities

Page 432

Volatile Amines Page 419

DB-1

DB-1

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.05 10 0.05 -60 to 325/350 126-1012

0.05 -60 to 325/350 126-10SP

0.20 -60 to 325/350 126-1013

0.10 5 0.12 -60 to 325/350 127-100A

10 0.10 -60 to 325/350 127-1012

0.40 -60 to 325/350 127-1013

20 0.10 -60 to 325/350 127-1022

0.40 -60 to 325/350 127-1023

40 0.20 -60 to 325/350 127-1046

0.40 -60 to 325/350 127-1043

0.15 10 1.20 -60 to 325/350 12A-1015

0.18 10 0.18 -60 to 325/350 121-1012

0.20 -60 to 325/350 121-101A

0.40 -60 to 325/350 121-1013

20 0.18 -60 to 325/350 121-1022

0.40 -60 to 325/350 121-1023

40 0.40 -60 to 325/350 121-1043

0.20 12 0.33 -60 to 325/350 128-1012

25 0.33 -60 to 325/350 128-1022

30 0.8 -60 to 325/350 128-1034

50 0.33 -60 to 325/350 128-1052

O Si

100%CH3

CH3

Page 23: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

240

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Life Sciences

Anabolic Steroids Page 458

Anticonvulsants Page 451

Petroleum

Aromatics in FinishedGasoline- ASTM Method 5769

Page 482

DNPH Derivative Page 424

Polyethylene Page 485

Regular Unleaded Gasoline(California Phase 1) -"Normal" GC Run II

Page 484

Volatile Sulfur Compounds Page 474

Polysiloxane Polymers Columns

DB-1 Chromatograms

0.25 15 0.10 -60 to 325/350 122-1011

0.25 -60 to 325/350 122-1012

1.00 -60 to 325/350 122-1013

25 0.25 -60 to 325/350 122-1022

30 0.10 -60 to 325/350 122-1031

0.25 -60 to 325/350 122-1032

0.50 -60 to 325/350 122-103E

1.00 -60 to 325/350 122-1033

50 0.25 -60 to 325/350 122-1052

60 0.10 -60 to 325/350 122-1061

0.25 -60 to 325/350 122-1062

0.50 -60 to 325/350 122-106E

1.00 -60 to 325/350 122-1063

100 0.50 -60 to 325/350 122-10AE

150 1.00 -60 to 325/350 122-10G3

0.32 15 0.10 -60 to 325/350 123-1011

0.25 -60 to 325/350 123-1012

1.00 -60 to 325/350 123-1013

3.00 -60 to 280/300 123-1014

5.00 -60 to 280/300 123-1015

25 0.12 -60 to 325/350 123-1027

0.25 -60 to 325/350 123-1022

0.52 -60 to 325/350 123-1026

1.05 -60 to 325/350 123-102F

30 0.10 -60 to 325/350 123-1031

0.25 -60 to 325/350 123-1032

0.50 -60 to 325/350 123-103E

1.00 -60 to 325/350 123-1033

1.50 -60 to 300/320 123-103B

3.00 -60 to 280/300 123-1034

5.00 -60 to 280/300 123-1035

50 0.25 -60 to 325/350 123-1052

0.52 -60 to 325/350 123-1056

1.05 -60 to 325/350 123-105F

1.20 -60 to 325/350 123-105C

5.00 -60 to 280/300 123-1055

60 0.10 -60 to 325/350 123-1061

0.25 -60 to 325/350 123-1062

0.50 -60 to 325/350 123-106E

1.00 -60 to 325/350 123-1063

1.50 -60 to 300/320 123-106B

2.00 -60 to 280/300 123-106G

3.00 -60 to 280/300 123-1064

5.00 -60 to 280/300 123-1065

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-1

Page 24: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

241

GC and GC/MS

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

0.45 30 1.27 -60 to 325/350 124-1032

2.55 -60 to 260/280 124-1034

0.53 5 2.65 -60 to 325/350 125-100B

5.00 -60 to 325/350 125-1005

7.5 1.50 -60 to 325/350 125-1002

10 2.65 -60 to 260/280 125-10HB

5.00 -60 to 260/280 125-10H5

15 0.15 -60 to 340/360 125-1011

0.25 -60 to 320/340 125-101K

0.50 -60 to 300/320 125-1017

1.00 -60 to 300/320 125-101J

1.50 -60 to 300/320 125-1012

3.00 -60 to 260/280 125-1014

5.00 -60 to 260/280 125-1015

25 1.00 -60 to 300/320 125-102J

5.00 -60 to 260/280 125-1025

30 0.10 -60 to 340/360 125-1039

0.25 -60 to 320/340 125-103K

0.50 -60 to 300/320 125-1037

1.00 -60 to 300/320 125-103J

1.50 -60 to 300/320 125-1032

2.65 -60 to 260/280 125-103B

3.00 -60 to 260/280 125-1034

5.00 -60 to 260/280 125-1035

50 5.00 -60 to 260/280 125-1055

60 1.00 -60 to 300/320 125-106J

1.50 -60 to 300/320 125-1062

3.00 -60 to 260/280 125-1064

5.00 -60 to 260/280 125-1065

105 5.00 -60 to 260/280 125-10B5

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-1

Page 25: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

HP-1

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091Z-577

0.20 12 0.33 -60 to 325/350 19091-60312

17 0.10 -60 to 325/350 19091Z-008

25 0.11 -60 to 325/350 19091Z-002

0.33 -60 to 325/350 19091Z-102

0.50 -60 to 325/350 19091Z-202

50 0.11 -60 to 325/350 19091Z-005

0.33 -60 to 325/350 19091Z-105

0.50 -60 to 325/350 19091Z-205

0.25 15 0.10 -60 to 325/350 19091Z-331

0.25 -60 to 325/350 19091Z-431

1.00 -60 to 325/350 19091Z-231

30 0.10 -60 to 325/350 19091Z-333

0.25 -60 to 325/350 19091Z-433

1.00 -60 to 325/350 19091Z-233

60 0.25 -60 to 325/350 19091Z-436

1.00 -60 to 325/350 19091Z-236

100 0.50 -60 to 325/350 19091Z-530

Structure of Dimethylpolysiloxane

• 100% Dimethylpolysiloxane

• Non-polar

• Excellent general purpose column – "Industry Standard"

• Wide range of applications

• Superior performance for low molecular weight alcohols (<C5)

• High temperature limit

• Bonded and cross-linked

• Solvent rinsable

• Wide range of column dimensions available

• Equivalent to USP Phase G2

Similar Phases: DB-1, Ultra-1, SPB-1, CP-Sil 5 CB, Rtx-1, BP-1, OV-1, OV-101, 007-1(MS),SP-2100, SE-30, CP-Sil 5 CB MS, ZB-1, AT-1, MDN-1, ZB-1

HP-1 Chromatograms

Environmental

Organotin Compounds I Page 380

Industrial Chemicals

Common Industrial Solvents Page 439

Inorganic Hydride Gases Page 446

Solvents IV Page 438

Petroleum

Denatured Fuel Ethanol-ASTM D5501

Page 481

Glycols/Diols Page 433

Oxygenates in GasolineASTM D5599 (GC-OFID)

Page 480

Sulfur Compounds inNatural Gas-SyntheticMixture

Page 478

HP-1

242

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

O Si

100%CH3

CH3

Page 26: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

2.65 -60 to 260/280 19095Z-123

3.00 -60 to 260/280 19095Z-423

5.00 -60 to 260/280 19095Z-623

60 5.00 -60 to 260/280 19095Z-626

0.32 15 0.25 -60 to 325/350 19091Z-411

1.00 -60 to 325/350 19091Z-211

25 0.17 -60 to 325/350 19091Z-012

0.52 -60 to 325/350 19091Z-112

1.05 -60 to 325/350 19091Z-212

30 0.10 -60 to 325/350 19091Z-313

0.25 -60 to 325/350 19091Z-413

1.00 -60 to 325/350 19091Z-213

3.00 -60 to 260/280 19091Z-513

4.00 -60 to 260/280 19091Z-613

5.00 -60 to 260/280 19091Z-713

50 0.17 -60 to 325/350 19091Z-015

0.52 -60 to 325/350 19091Z-115

1.05 -60 to 325/350 19091Z-215

60 0.25 -60 to 325/350 19091Z-416

1.00 -60 to 325/350 19091Z-216

5.00 -60 to 260/280 19091Z-716

0.53 5 0.15 -60 to 320/400 19095Z-220

0.88 -60 to 320/400 19095Z-020

-60 to 325/350 125-100A

2.65 -60 to 260/280 19095S-100

7.5 5.00 -60 to 260/280 19095Z-627

10 0.88 -60 to 300/320 19095Z-021

2.65 -60 to 260/280 19095Z-121

15 0.15 -60 to 320/400 19095Z-221

1.50 -60 to 300/320 19095Z-321

3.00 -60 to 260/280 19095Z-421

5.00 -60 to 260/280 19095Z-621

30 0.88 -60 to 300/320 19095Z-023

1.50 -60 to 300/320 19095Z-323

243

GC and GC/MS

www.agilent.com/chem/supplies

Polysiloxane Polymers ColumnsPolysiloxane Polymers Columns

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

HP-1

Page 27: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

244

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• (5%-Phenyl)-methylpolysiloxane

• Non-polar

• Excellent general purpose column

• Wide range of applications

• Low bleed

• High temperature limit

• Bonded and cross-linked

• Solvent rinsable

• Wide range of column dimensions available

• Equivalent to USP Phase G27

Similar Phases: HP-5, Ultra-2, SPB-5, CP-Sil 8CB, Rtx-5, BP-5, OV-5, 007-2(MPS-5), SE-52,SE-54, XTI-5, PTE-5, HP-5MS, ZB-5, AT-5, MDN-5, ZB-5

DB-5 Chromatograms

Environmental

Organochlorine Pesticides,DB5/1701P

Page 368

Food, Flavors and Fragrances

Bacterial Fatty Acid MethylEsters

Page 409

Cold-Pressed Orange Oil Page 402

Lemon Oil Page 402

Life Sciences

Amphetamines andPrecursors - TMSDerivatives

Page 450

Antihistamines Page 451

Common Drug Screen Page 448

Marijuana (D9-THC) andMajor Metabolites - TMSDerivatives

Page 460

Narcotics and Adulterants Page 456

Over-the-Counter PainKillers - TMS Derivatives

Page 457

DB-5

Polysiloxane Polymers Columns

Structure of Diphenyldimethylpolysiloxane

DB-5

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 10 0.10 -60 to 325/350 127-5012

0.17 -60 to 325/350 127-501E

0.33 -60 to 325/350 127-501N

0.40 -60 to 325/350 127-5013

20 0.10 -60 to 325/350 127-5022

0.40 -60 to 325/350 127-5023

0.15 10 1.20 -60 to 300/320 12A-5015

0.18 10 0.18 -60 to 325/350 121-5012

0.40 -60 to 325/350 121-5013

20 0.18 -60 to 325/350 121-5022

0.40 -60 to 325/350 121-5023

40 0.18 -60 to 325/350 121-5042

0.20 12 0.33 -60 to 325/350 128-5012

15 0.20 -60 to 325/350 128-50H7

25 0.33 -60 to 325/350 128-5022

50 0.33 -60 to 325/350 128-5052

0.25 15 0.10 -60 to 325/350 122-5011

0.25 -60 to 325/350 122-5012

0.50 -60 to 325/350 122-501E

1.00 -60 to 325/350 122-5013

25 0.25 -60 to 325/350 122-5022

30 0.10 -60 to 325/350 122-5031

0.25 -60 to 325/350 122-5032

0.50 -60 to 325/350 122-503E

1.00 -60 to 325/350 122-5033

O Si

CH3

CH3

O Si

CH6H5

CH6H5 5%95%

50 0.25 -60 to 325/350 122-5052

60 0.10 -60 to 325/350 122-5061

0.25 -60 to 325/350 122-5062

0.50 -60 to 325/350 122-506E

1.00 -60 to 325/350 122-5063

Page 28: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

245

GC and GC/MS

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

0.32 15 0.10 -60 to 325/350 123-5011

0.25 -60 to 325/350 123-5012

1.00 -60 to 325/350 123-5013

25 0.17 -60 to 325/350 123-502D

0.25 -60 to 325/350 123-5022

0.52 -60 to 325/350 123-5026

1.05 -60 to 325/350 123-502F

30 0.10 -60 to 325/350 123-5031

0.25 -60 to 325/350 123-5032

0.50 -60 to 325/350 123-503E

1.00 -60 to 325/350 123-5033

1.50 -60 to 325/350 123-503B

50 0.25 -60 to 325/350 123-5052

0.52 -60 to 325/350 123-5056

1.00 -60 to 325/350 123-5053

60 0.25 -60 to 325/350 123-5062

1.00 -60 to 325/350 123-5063

0.45 15 1.27 -60 to 300/320 124-5012

30 0.42 -60 to 300/320 124-5037

1.27 -60 to 300/320 124-5032

0.53 10 2.65 -60 to 260/280 125-50HB

15 0.25 -60 to 300/320 125-501K

0.50 -60 to 300/320 125-5017

1.00 -60 to 300/320 125-501J

1.50 -60 to 300/320 125-5012

25 5.00 -60 to 260/280 125-5025

30 0.25 -60 to 300/320 125-503K

0.50 -60 to 300/320 125-5037

0.88 -60 to 300/320 125-503D

1.00 -60 to 300/320 125-503J

1.50 -60 to 300/320 125-5032

2.65 -60 to 260/280 125-503B

3.00 -60 to 260/280 125-5034

5.00 -60 to 260/280 125-5035

60 1.50 -60 to 300/320 125-5062

5.00 -60 to 260/280 125-5065

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-5

Page 29: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

246

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• (5%-Phenyl)-methylpolysiloxane

• Non-polar

• Excellent general purpose column

• Wide range of applications

• High temperature limit

• Bonded and cross-linked

• Solvent rinsable

• Wide range of column dimensions available

• Equivalent to USP Phase G27

Similar Phases: DB-5, Ultra-2, SPB-5, CP-Sil 8 CB, Rtx-5, BP-5, OV-5, 007-2(MPS-5), SE-52,SE-54, XTI-5, PTE-5, HP-5MS, ZB-5, AT-5, MDN-5, ZB-5

HP-5 Chromatograms

Environmental

Organotin Compounds II Page 381

HP-5

Polysiloxane Polymers Columns

Structure of Diphenyldimethylpolysiloxane

HP-5

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091J-577

0.20 12 0.33 -60 to 325/350 19091J-101

25 0.11 -60 to 325/350 19091J-002

0.33 -60 to 325/350 19091J-102

0.50 -60 to 325/350 19091J-202

50 0.11 -60 to 325/350 19091J-005

0.33 -60 to 325/350 19091J-105

0.50 -60 to 325/350 19091J-205

O Si O Si

CH3

C6H

5

C6H

5CH

3 5%95%

0.25 5 0.10 -60 to 325/350 19091J-330

15 0.25 -60 to 325/350 19091J-431

1.00 -60 to 325/350 19091J-231

30 0.10 -60 to 325/350 19091J-333

0.25 -60 to 325/350 19091J-433

1.00 -60 to 325/350 19091J-233

60 0.25 -60 to 325/350 19091J-436

1.00 -60 to 325/350 19091J-236

Page 30: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

247

GC and GC/MS

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

0.32 15 0.25 -60 to 325/350 19091J-411

25 0.17 -60 to 325/350 19091J-012

0.52 -60 to 325/350 19091J-112

1.05 -60 to 325/350 19091J-212

30 0.10 -60 to 325/350 19091J-313

0.25 -60 to 325/350 19091J-413

0.50 -60 to 325/350 19091J-113

1.00 -60 to 325/350 19091J-213

50 0.17 -60 to 325/350 19091J-015

0.52 -60 to 325/350 19091J-115

1.05 -60 to 325/350 19091J-215

60 0.25 -60 to 325/350 19091J-416

1.00 -60 to 325/350 19091J-216

0.53 10 2.65 -60 to 260/280 19095J-121

15 1.50 -60 to 300/320 19095J-321

5.00 -60 to 260/280 19095J-621

30 0.88 -60 to 300/320 19095J-023

1.50 -60 to 300/320 19095J-323

2.65 -60 to 260/280 19095J-123

5.00 -60 to 260/280 19095J-623

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

HP-5

Page 31: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

248

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• Non-polar

• 100% Dimethylpolysiloxane

• Equivalent to HP-1 with tighter specifications for retention index and capacity factors

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: DB-1, HP-1, SPB-1, CP-Sil 5 CB, Rtx-1, BP-1, 007-1(MS)

Ultra 1 Chromatograms

Industrial Chemicals

Ethylene Glycol Mixture Page 433

Pyrolysates of Polystyrene Page 428

Ultra 1

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 12 0.33 -60 to 325/350 19091A-101

17 0.11 -60 to 325/350 19091A-008

25 0.11 -60 to 325/350 19091A-002

0.33 -60 to 325/350 19091A-102

50 0.11 -60 to 325/350 19091A-005

0.33 -60 to 325/350 19091A-105

0.32 25 0.17 -60 to 325/350 19091A-012

0.52 -60 to 325/350 19091A-112

50 0.17 -60 to 325/350 19091A-015

0.52 -60 to 325/350 19091A-115

Ultra 1

Polysiloxane Polymers Columns

• Non-polar

• (5%-Phenyl)-methylpolysiloxane

• Equivalent to HP-5 with tighter specifications for retention index and capacity factors

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: DB-5, HP-5, SPB-5, CP-Sil 8 CB, Rtx-5, BP-5, CB-5, 007-5, 2B-5

Ultra 2 Chromatograms

Food, Flavors and Fragrances

Flavor Mixture Page 401

Life Sciences

Antiepileptic Drugs Page 452

Tricyclic Antipsychotics Page 452

Urine Drug Screen Page 449 Ultra 2

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 12 0.33 -60 to 325/350 19091B-101

25 0.11 -60 to 325/350 19091B-002

0.33 -60 to 325/350 19091B-102

50 0.11 -60 to 325/350 19091B-005

0.33 -60 to 325/350 19091B-105

0.32 25 0.17 -60 to 325/350 19091B-012

0.52 -60 to 325/350 19091B-112

50 0.17 -60 to 325/350 19091B-015

0.52 -60 to 325/350 19091B-115

Ultra 2

Page 32: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

249

GC and GC/MS

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

• (35%-Phenyl)-methylpolysiloxane

• Mid-polarity – slightly more polar than HP-35

• Low bleed

• Inert to active solutes

• Ideal for confirmational analyses

• Bonded and cross-linked

• Solvent rinsable

• Equivalent to USP Phase G42

Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, HP-35, BPX-35

DB-35

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 40 to 300/320 122-1932

60 0.25 40 to 300/320 122-1962

0.32 30 0.25 40 to 300/320 123-1932

0.50 40 to 300/320 123-1933

0.53 15 1.00 40 to 280/300 125-1912

30 0.50 40 to 280/300 125-1937

1.00 40 to 280/300 125-1932

DB-35

Structure of Diphenyldimethylpolysiloxane

DB-35 Chromatograms

Environmental

Organochlorine Pesticides IV Page 367

Nitrogen/PhosphorusContaining Pesticides, EPA Method 507

Page 369

O Si O Si

CH3

C6H

5

C6H

5CH

3 35%65%

• (35%-Phenyl)-methylpolysiloxane

• Mid-polarity – slightly less polar than DB-35

• Inert to active solutes

• Ideal for confirmational analyses

• Bonded and cross-linked

• Solvent rinsable

• Equivalent to USP Phase G42

Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, DB-35, BPX-35

HP-35

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.25 40 to 300/320 19091G-131

30 0.25 40 to 300/320 19091G-133

0.32 30 0.25 40 to 300/320 19091G-113

0.50 40 to 300/320 19091G-213

HP-35

HP-35 Chromatograms

Industrial Chemicals

Polymer Additives Page 446

Structure of Diphenyldimethylpolysiloxane

O Si O Si

CH3

C6H

5

C6H

5CH

3 35%65%

Page 33: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

250

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

DB-17

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.05 10 0.10 40 to 280/300 126-1713

0.10 10 0.10 40 to 280/300 127-1712

0.20 40 to 280/300 127-1713

20 0.10 40 to 280/300 127-1722

0.18 20 0.18 40 to 280/300 121-1722

0.30 40 to 280/300 121-1723

0.25 15 0.15 40 to 280/300 122-1711

0.25 40 to 280/300 122-1712

0.50 40 to 280/300 122-1713

30 0.15 40 to 280/300 122-1731

0.25 40 to 280/300 122-1732

0.50 40 to 280/300 122-1733

60 0.25 40 to 280/300 122-1762

0.32 15 0.15 40 to 280/300 123-1711

0.25 40 to 280/300 123-1712

0.50 40 to 280/300 123-1713

30 0.15 40 to 280/300 123-1731

0.25 40 to 280/300 123-1732

0.50 40 to 280/300 123-1733

60 0.25 40 to 280/300 123-1762

0.53 5 2.00 40 to 280/300 125-1704

15 0.25 40 to 260/280 125-1711

0.50 40 to 260/280 125-1717

1.00 40 to 260/280 125-1712

1.50 40 to 260/280 125-1713

30 0.25 40 to 260/280 125-1731

0.50 40 to 260/280 125-1737

1.00 40 to 260/280 125-1732

1.50 40 to 260/280 125-1733

60 1.00 40 to 260/280 125-1762

• (50%-Phenyl)-methylpolysiloxane

• Mid-polarity – slightly more polar than HP-50+

• Excellent for confirmational analyses

• Bonded and cross-linked

• Solvent rinsable

• Equivalent to USP Phase G3

Similar Phases: HP-50+, Rtx-50, CP-Sil 24 CB, 007-17(MPS-50), HP-17, SP-2250, SPB-50,ZB-50, AT-50DB-17 Chromatograms

Life Sciences

Common Drug Screen Page 448

Free Steroids Page 458

Polysiloxane Polymers Columns

DB-17

O Si O Si

CH3

C6H

5

C6H

5CH

3 50%50%

Structure of Diphenyldimethylpolysiloxane

Page 34: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

251

GC and GC/MS

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

Structure of Diphenyldimethylpolysiloxane

• (50%-Phenyl)-methylpolysiloxane

• Mid-polarity – slightly less polar than DB-17

• Excellent for confirmational analyses

• Bonded and cross-linked

• Solvent rinsable

• Equivalent to USP Phase G3

Similar Phases: DB-17, Rtx-50, CP-Sil 24 CB, 007-17(MPS-50), SP-2250, SPB-50, ZB-50, AT-50

HP-50+

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 40 to 280/300 19091L-577

0.20 12 0.31 40 to 280/300 19091L-101

0.25 5 0.15 40 to 280/300 19091L-330

15 0.25 40 to 280/300 19091L-431

30 0.15 40 to 280/300 19091L-333

0.25 40 to 280/300 19091L-433

0.50 40 to 280/300 19091L-133

0.32 15 0.50 40 to 280/300 19091L-111

30 0.25 40 to 280/300 19091L-413

0.50 40 to 280/300 19091L-113

60 0.25 40 to 280/300 19091L-416

0.53 15 1.00 40 to 260/280 19095L-021

30 0.50 40 to 260/280 19095L-523

1.00 40 to 260/280 19095L-023

HP-50+CH3

O

C6H5

O

CH3 50%

Si Si

C6H5 50%

Page 35: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

252

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

Structure of cyanpropylmethylpolysiloxane

• (50%-Cyanopropyl)-methylpolysiloxane

• High polarity

• Designed for separation of fatty acid methyl esters (FAMEs)

• Excellent resolution for cis- and trans-isomers

• Bonded and cross-linked

• Solvent rinsable

• Replaces HP-23

• Close equivalent to USP Phase G5

Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, BPX-70, SP-2340, VF-23ms

DB-23 Chromatograms

Food, Flavors and Fragrances

Canola Oil Margarine Partially HydrogenatedFAMEs AOCS Method 1c-89

Page 414

FAMEs I Page 410

DB-23

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.20 40 to 250/260 121-2323

0.25 15 0.25 40 to 250/260 122-2312

30 0.15 40 to 250/260 122-2331

0.25 40 to 250/260 122-2332

60 0.15 40 to 250/260 122-2361

0.25 40 to 250/260 122-2362

0.32 30 0.25 40 to 250/260 123-2332

60 0.25 40 to 250/260 123-2362

0.53 15 0.50 40 to 230/240 125-2312

30 0.50 40 to 230/240 125-2332

CH2

CN

CH3

CH2

CH2

O Si

n

DB-23

Structure of cyanopropylaryl-polysiloxane

• (88%-cyanopropyl)aryl-polysiloxane

• 250/320°C upper temperature limits

• High Polarity

• Designed for separation of cis/trans fatty acid methyl esters (FAMES)

• Even better separation than DB-23 of cis-trans isomers

Similar Phases: CP-Sil 88, SP-2560, SP-2340, SP-2330, BPX-70, BPX-90

HP-88 Chromatograms

Food, Flavors and Fragrances

69 Component FAME Mix Page 411

HP-88

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 100 0.20 0 to 250/260 112-88A7

60 0.20 0 to 250/260 112-8867

30 0.20 0 to 250/260 112-8837

Me

Me

Me

Me

Me

Me

Me

SiSiSiSi O O

Me

Me

MeSiC

C

C

N

N n

m

HP-88

Page 36: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

253

GC and GC/MS

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

Structure of trifluoropropylmethylpolysiloxane

• (35% Trifluoropropyl)-methylpolysiloxane

• 300/320°C temperature limit

• Mid-polarity – more polar than DB-1701 or DB-17

• Ideal for difficult to separate positional isomers

• Unique interactions with compounds containing nitro, halogen and carbonyl groups

• Low ECD bleed

• Unique selectivity

• Close equivalent to USP Phase G6

Similar Phases: Rtx-200, VF-200msDB-200 Chromatograms

Industrial Chemicals

Acrylate Impurities I Page 440

Aromatic Solvents Page 438

Solvents I Page 436

DB-200

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 30 to 300/320 122-2032

0.50 30 to 300/320 122-2033

0.32 30 0.25 30 to 300/320 123-2032

0.50 30 to 300/320 123-2033

0.53 30 1.00 30 to 280/300 125-2032

DB-200

• (50%-Trifluoropropyl)-methylpolysiloxane

• High polarity

• Excellent for U.S. EPA Methods 8140 and 609

• Bonded and cross-linked

• Solvent rinsable

• Exact replacement of HP-210

• Close equivalent to USP Phase G6

Similar Phases: SP-2401

DB-210

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.25 45 to 240/260 122-0212

30 0.25 45 to 240/260 122-0232

0.50 45 to 240/260 122-0233

0.32 15 0.50 45 to 240/260 123-0213

30 0.25 45 to 240/260 123-0232

0.50 45 to 240/260 123-0233

0.53 15 1.00 45 to 220/240 125-0212

30 1.00 45 to 220/240 125-0232

DB-210

DB-210 Chromatograms

Environmental

Herbicides II Page 371

CF 3

CH 2

CH 2

O Si

CH 3 n

CF 3

CH 2

CH 2

O Si

CH 3 n

Structure of trifluoropropylmethylpolysiloxane

Page 37: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

254

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

Structure of cyanopropylphenylmethylpolysiloxane

• (50%-Cyanopropylphenyl)-dimethylpolysiloxane

• Mid/high polarity

• Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs)

• Bonded and cross-linked

• Solvent rinsable

• Exact replacement of HP-225

• Close equivalent to USP Phase G7

Similar Phases: SP-2330, CP-Sil 43 CB, Rtx-225, BP-225, OV-225, 007-225, AT-225

DB-225 Chromatograms

Environmental

Tetrachlorodibenzo-p-furans Page 374

Food, Flavors and Fragrances

Alditol Acetates Page 406

FAME Standard II Page 413

DB-225

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 20 0.10 40 to 220/240 127-2222

0.18 20 0.20 40 to 220/240 121-2223

0.25 15 0.25 40 to 220/240 122-2212

30 0.15 40 to 220/240 122-2231

0.25 40 to 220/240 122-2232

0.32 30 0.25 40 to 220/240 123-2232

0.53 15 1.00 40 to 200/220 125-2212

30 0.50 40 to 200/220 125-2237

1.00 40 to 200/220 125-2232

CH2

CN

C6H5

CH2

CH2

O Si

50%CH3

CH3

O Si

50%

DB-225

Tips & Tools

Need assistance selecting a column for your method? Contact ourchromatography technical specialists at www.agilent.com/chem/TechRep.

Page 38: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

255

GC and GC/MS

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

DB-1301

• (6%-Cyanopropyl-phenyl) methylpolysiloxane

• Equivalent to USP Phase G43

• Low/mid-polarity

• Bonded and cross-linked

• Exact replacement of HP-1301 and HP-1701

• Solvent rinsable

Similar Phases: Rtx-1301, PE-1301, VF-1301ms

DB-1301

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 10 0.40 -20 to 280/300 121-1313

0.25 30 0.25 -20 to 280/300 122-1332

1.00 -20 to 280/300 122-1333

60 0.25 -20 to 280/300 122-1362

1.00 -20 to 280/300 122-1363

0.32 30 0.25 -20 to 280/300 123-1332

1.00 -20 to 280/300 123-1333

60 1.00 -20 to 280/300 123-1363

0.53 15 1.00 -20 to 260/280 125-1312

30 1.00 -20 to 260/280 125-1332

1.50 -20 to 260/280 125-1333

Tips & Tools

Selecting the right column is only part of the total solution. Don't forget keysupplies such as septa, liners and seals.

Turn to pages 148-157.

Page 39: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

256

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Polysiloxane Polymers Columns

DB-1701

• (14%-Cyanopropyl-phenyl)-methylpolysiloxane

• Low/mid-polarity

• Bonded and cross-linked

• Exact replacement of HP-1301 and HP-1701

• Solvent rinsable

Similar Phases: SPB-1701, CP-Sil 19 CB, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-1701, VF-1701ms

DB-1701 Chromatograms

Environmental

Organochlorine Pesticides III Page 367

Phenoxy Acid Herbicides Page 371

Food, Flavors and Fragrances

TMS Sugars Page 408

Industrial Chemicals

Acrylate Impurities II Page 441

Life Sciences

Fentanyls Page 454

DB-1701

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 20 0.10 -20 to 280/300 127-0722

0.40 -20 to 280/300 127-0723

0.18 10 0.40 -20 to 280/300 121-0713

20 0.18 -20 to 280/300 121-0722

0.25 15 0.25 -20 to 280/300 122-0712

1.00 -20 to 280/300 122-0713

30 0.15 -20 to 280/300 122-0731

0.25 -20 to 280/300 122-0732

1.00 -20 to 280/300 122-0733

60 0.15 -20 to 280/300 122-0761

0.25 -20 to 280/300 122-0762

0.50 -20 to 280/300 122-0766

1.00 -20 to 280/300 122-0763

0.32 15 0.25 -20 to 280/300 123-0712

1.00 -20 to 280/300 123-0713

30 0.15 -20 to 280/300 123-0731

0.25 -20 to 280/300 123-0732

1.00 -20 to 280/300 123-0733

50 1.00 -20 to 280/300 123-0753

60 0.25 -20 to 280/300 123-0762

1.00 -20 to 280/300 123-0763

0.53 15 1.00 -20 to 260/280 125-0712

30 0.25 -20 to 260/280 125-0731

0.50 -20 to 260/280 125-0737

1.00 -20 to 260/280 125-0732

1.50 -20 to 260/280 125-0733

60 1.00 -20 to 260/280 125-0762

Agilent also offers DB-624columns for the analysis ofvolatile priority pollutants and residual solvents.

Tips & Tools

Turn to page 280.

Page 40: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

257

GC and GC/MS

www.agilent.com/chem/supplies

Structure of Polyethylene glycol

Polyethylene Glycol (PEG) Columns

Agilent offers a full range of PEG columns. Even though each phase is based on thepolyethylene glycol polymer, strict control of the cross-linking and deactivation processesresult in a variety of unique phase characteristics to meet the varying analysis needs of your laboratory.

PEG Column Features Benefits

DB-WAXDB-WaxFF

� Lowest operating temperature limit� Most similar to Carbowax 20M� Available in 0.10 mm ID� Highly inert

� Analyze low boiling point analytes� Transfer older methods to

bonded phase� Used for Fast GC for high

sample throughput� Broad analyte compatibility

DB-WAXetr � Middle operating temperature range

� Compromise for high and lowboiling analytes

HP-INNOWax � Highest upper temperature limit� Wide chemical compatibility� Lowest bleed at elevated

temperatures� Highly inert

� Analyze high boiling point compounds

� Excellent general purpose column� Best choice for MS use� Broad analyte compatibility

DB-FFAP, HP-FFAP � Acid modified � Can inject organic acids without derivization

CAM � Base modified � Non-bonded

� Good peak shape for basic compounds

� Cannot be solvent rinsed

n

H H

C C O

H H

H-HO

Polyethylene Glycol (PEG) Columns

Page 41: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

258

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• Polyethylene glycol (PEG)

• Equivalent to USP Phase G16

• High polarity

• Lower temperature limit of 20°C is the lowest of any bonded PEG phase; improves resolution of low boiling point analytes

• Column-to-column reproducibility

• Bonded and cross-linked

• Exact replacement of HP-WAX

• Solvent rinsable

• DB-WaxFF is a highly reproducible, specially tested microbore DB-Wax for fragrance analysis

Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,Stabilwax, BP-20, 007-CW, Carbowax, HP-INNOWax, Rtx-WAX, ZB-WAX, VF-WAXms

DB-WAX and DB-WaxFF

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-WAX

0.05 10 0.05 20 to 250/260 126-7012

0.10 20 to 240/250 126-7013

0.10 10 0.10 20 to 250/260 127-7012

0.20 20 to 240/250 127-7013

20 0.10 20 to 250/260 127-7022

0.20 20 to 240/250 127-7023

0.18 10 0.18 20 to 250/260 121-7012

20 0.18 20 to 250/260 121-7022

0.30 20 to 240/250 121-7023

40 0.18 20 to 250/260 121-7042

0.30 20 to 240/250 121-7043

0.20 25 0.20 20 to 250/260 128-7022

30 0.20 20 to 250/260 128-7032

50 0.20 20 to 250/260 128-7052

DB-WAX and DB-WaxFF

Polyethylene Glycol (PEG) Columns

DB-WAX and DB-WaxFFChromatograms

Food, Flavors and Fragrances

FAME Standard I Page 412

Fragrance ReferenceStandard II

Page 399

Lavender Oil Spiked with Camphor

Page 400

Peppermint Oil Page 403

Spearmint Oil (Western) Page 403

Ylang Ylang Oil II Page 404

Industrial Chemicals

Aldehydes and Ketones Page 423

Aromatics II Page 426

Ethylene Oxide Page 445

Formaldehyde Underivatized Page 424

Glycols I Page 431

Impurities in Styrene Page 427

Phenols III Page 444

Page 42: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

259

GC and GC/MS

www.agilent.com/chem/supplies

Polyethylene Glycol (PEG) Columns

0.25 15 0.25 20 to 250/260 122-7012

0.50 20 to 240/250 122-7013

30 0.15 20 to 250/260 122-7031

0.25 20 to 250/260 122-7032

0.50 20 to 240/250 122-7033

60 0.15 20 to 250/260 122-7061

0.25 20 to 250/260 122-7062

0.50 20 to 240/250 122-7063

0.32 15 0.25 20 to 250/260 123-7012

0.50 20 to 240/250 123-7013

30 0.15 20 to 250/260 123-7031

0.25 20 to 250/260 123-7032

0.50 20 to 240/250 123-7033

60 0.25 20 to 250/260 123-7062

0.50 20 to 240/250 123-7063

0.45 30 0.85 20 to 230/240 124-7032

0.53 15 0.50 20 to 230/240 125-7017

1.00 20 to 230/240 125-7012

30 0.25 20 to 230/240 125-7031

0.50 20 to 230/240 125-7037

1.00 20 to 230/240 125-7032

60 1.00 20 to 230/240 125-7062DB-WaxFF

0.10 20 0.20 20 to 240/250 127-7023FF

DB-WAX

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-WAX and DB-WaxFF

Tips & Tools

Ghost peaks can be caused by cored septa materialaccumulating in the inlet. To prevent coring, use AgilentPremium Non-Stick Septa with CenterGuide.

Turn to pages 148–150.

Page 43: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

260

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• Polyethylene glycol (PEG)

• Extended Temperature Range (etr)

• High polarity

• Excellent column-to-column repeatability

• Bonded and cross-linked

• Solvent rinsable

• Equivalent to USP Phase G16

Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,Stabilwax, BP-20, 007-CW, Carbowax, HP-INNOWax, ZB-WAX

DB-WAXetr Chromatograms

Industrial Chemicals

Alcohols II Page 417

Impurities in Mixed Xylenes Page 428

Impurities in Styrene Page 427

Organic Acids Page 418

Solvents I Page 436

Solvents II Page 437

DB-WAXetr

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.40 30 to 250/260 128-7323

0.25 30 0.25 30 to 260/280 122-7332

0.50 30 to 250/260 122-7333

60 0.25 30 to 260/280 122-7362

0.50 30 to 250/260 122-7363

0.32 15 0.25 30 to 260/280 123-7312

1.00 30 to 250/260 123-7314

30 0.25 30 to 260/280 123-7332

0.50 30 to 250/260 123-7333

1.00 30 to 250/260 123-7334

50 1.00 30 to 250/260 123-7354

60 0.25 30 to 260/280 123-7362

0.50 30 to 250/260 123-7363

1.00 30 to 250/260 123-7364

0.53 15 1.00 30 to 240/260 125-7312

2.00 50 to 230/250 125-7314

30 1.00 30 to 240/260 125-7332

1.50 30 to 230/240 125-7333

2.00 50 to 230/250 125-7334

60 1.00 30 to 240/260 125-7362

DB-WAXetr

Polyethylene Glycol (PEG) Columns

Page 44: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

261

GC and GC/MS

www.agilent.com/chem/supplies

Polyethylene Glycol (PEG) Columns

• Polyethylene glycol (PEG)

• High polarity

• Highest upper temperature limits of the bonded PEG phases

• Column-to-column repeatability

• Bonded and cross-linked

• Solvent rinsable

• Close equivalent to USP Phase G16

Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,Stabilwax, BP-20, 007-CW, Carbowax, DB-WAXetr, ZB-WAX

HP-INNOWax

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 40 to 260/270 19091N-577

0.20 25 0.20 40 to 260/270 19091N-102

0.40 40 to 260/270 19091N-202

50 0.20 40 to 260/270 19091N-105

0.40 40 to 260/270 19091N-205

0.25 4 0.25 40 to 260/270 19091N-130

5 0.15 40 to 260/270 19091N-030

15 0.10 40 to 260/270 19091N-331

0.25 40 to 260/270 19091N-131

0.50 40 to 260/270 19091N-231

30 0.15 40 to 260/270 19091N-033

0.25 40 to 260/270 19091N-133

0.50 40 to 260/270 19091N-233

60 0.15 40 to 260/270 19091N-036

0.25 40 to 260/270 19091N-136

0.50 40 to 260/270 19091N-236

0.32 15 0.25 40 to 260/270 19091N-111

30 0.15 40 to 260/270 19091N-013

0.25 40 to 260/270 19091N-113

0.50 40 to 260/270 19091N-213

60 0.25 40 to 260/270 19091N-116

0.50 40 to 260/270 19091N-216

0.53 15 1.00 40 to 240/250 19095N-121

30 1.00 40 to 240/250 19095N-123

60 1.00 40 to 240/250 19095N-126

HP-INNOWaxHP-INNOWax Chromatograms

Food, Flavors and Fragrances

Bourbon Page 406

Free Fatty Acids Page 408

Perfume Page 400

Polyunsaturated Fatty AcidMethyl Esters

Page 411

Strawberry Syrup Page 407

Sulfur and Selenium inGarlic by Headspace

Page 407

Industrial Chemicals

Alcohols III Page 418

Aldehydes and Acids Page 422

Free Organic Acids/C4-C5 Isomers

Page 419

Chlorinated Isooctane Page 436

Esters III Page 430

Impurities in Ethylbenzene Page 427

Petroleum

Aromatics Analysis -Ethylbenzene Impurities

Page 479

Aromatics Analysis: ASTM D16 Analytes

Page 478

Fast Analysis of Aromatic Solvent

Page 464

Impurities in p-Xylene -ASTM D3798

Page 479

Page 45: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

262

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• Nitroterephthalic acid modified polyethylene glycol

• High polarity

• Temperature range from 40° to 250°C

• Designed for the analysis of volatile fatty acids and phenols

• Replaces OV-351

• Bonded and cross-linked

• Solvent rinsable

• Close equivalent to USP Phase G35

We do not recommend the use of water or methanol to rinse DB-FFAP GC columns.

Similar Phases: Stabilwax-DA, HP-FFAP, Nukol, 007-FFAP, BP21, CP-Wax 58 (FFAP) CB, AT-1000, OV-351, CP-FFAP-CB

DB-FFAP Chromatograms

Food, Flavors and Fragrances

Organic Acids Page 409

Life Sciences

Aspirin and Ibuprofen in Methanol

Page 457

DB-FFAP

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 10 0.10 40 to 250 127-3212

15 10 40 to 250 127-32H2

0.25 15 0.25 40 to 250 122-3212

30 0.25 40 to 250 122-3232

0.50 40 to 250 122-3233

60 0.25 40 to 250 122-3262

0.50 40 to 250 122-3263

0.32 15 0.25 40 to 250 123-3212

25 0.50 40 to 250 123-3223

30 0.25 40 to 250 123-3232

0.50 40 to 250 123-3233

1.00 40 to 250 123-3234

50 0.50 40 to 250 123-3253

60 0.25 40 to 250 123-3262

0.50 40 to 250 123-3263

1.00 40 to 250 123-3264

0.45 30 0.85 40 to 250 124-3232

0.53 10 1.00 40 to 250 125-32H2

15 0.50 40 to 250 125-3217

1.00 40 to 250 125-3212

30 0.25 40 to 250 125-3231

0.50 40 to 250 125-3237

1.00 40 to 250 125-3232

1.50 40 to 250 125-3233

60 1.00 40 to 250 125-3262

DB-FFAP

Polyethylene Glycol (PEG) Columns

Page 46: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

263

GC and GC/MS

www.agilent.com/chem/supplies

Polyethylene Glycol (PEG) Columns

• Nitroterephthalic acid modified polyethylene glycol

• High polarity

• Temperature range from 60° to 240/250°C (230/240°C for 0.53 mm)

• Designed for the analysis of volatile fatty acids and phenols

• Replaces OV-351

• Bonded and cross-linked

• Solvent rinsable

• Close equivalent to USP Phase G35

We do not recommend the use of water or methanol to rinse HP-FFAP GC columns.

Similar Phases: Stabilwax-DA, DB-FFAP, Nukol, 007-FFAP, BP21, CP-WAX 58 (FFAP) CB, AT-1000, OV-351, CP-FFAP-CB

HP-FFAP Chromatograms

Food, Flavors and Fragrances

Alcohol Beverage Standard Page 406

Industrial Chemicals

Acrylates Page 441

Ethoxyethanol Page 418

HP-FFAP

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.30 60 to 240/250 19091F-102

50 0.30 60 to 240/250 19091F-105

0.25 30 0.25 60 to 240/250 19091F-433

0.32 25 0.50 60 to 240/250 19091F-112

30 0.25 60 to 240/250 19091F-413

50 0.50 60 to 240/250 19091F-115

0.53 10 1.00 60 to 240 19095F-121

15 1.00 60 to 240 19095F-120

30 1.00 60 to 240 19095F-123

HP-FFAP

Tips & Tools

Agilent also offers CAM columns for amine analysis.

Turn to page 293.

Page 47: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

264

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Special Application Columns

Special Application Columns

Agilent chemists have developed many columns with unique characteristics designed to solve the most difficult separation problems of a given method. As a result, we offer acomprehensive line of specialty columns for a variety of applications to enhance the standardphase portfolio. From columns for volatiles to pesticides to petrochemical and more – Agilent exceeds standard QA/QC procedures for the manufacturing and testing of all of our specialty columns to ensure they meet the stringent demands for their application. These columns offer reliable, accurate results with the shortest run times possible on complex sample lists and matrices.

Biodiesel Capillary GC Columns

Biofuels are becoming more attractive as a viable supplement or alternative to petroleum-based fuels. Agilent J&W Biodiesel Capillary GC columns are purposely designed andapplication-optimized for the analysis of biodiesel to meet ASTM and CEN testing standards.

Biodiesel EN14105 Free/Total Glycerin and Biodiesel ASTM D6584 Free/Total Glycerin

• Designed for the analysis of free and total glycerin in B100 according to EN14105 or ASTM D6584

• Specially processed for extended temperature limit of 400°C

• High temperature, polyimide-coated fused silica tubing

• Excellent peak shape and extended column life

• Bonded and cross-linked

• Solvent rinsable

• Retention gaps please order 160-BD65-5 (5m x 0.53 mm)

NEW!

Page 48: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

265

GC and GC/MS

www.agilent.com/chem/supplies

Chiral Columns Special Application Columns

Biodiesel EN14103 FAME Analysis

• Specially designed for the analysis of esters and linoleic acid methyl esters in B100 using EN14103

• Bonded and cross-linked

• Solvent rinsable

Biodiesel EN14110 Residual Methanol

Biodiesel Capillary GC Columns

Description ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

Biodiesel ASTM D6584Free/Total Glycerin

0.32 15 0.1 -60 to 400 123-BD11

Biodiesel EN14105Free/Total Glycerin

0.32 10 0.1 -60 to 400 123-BD01

Biodiesel EN14103 FAME Analysis

0.32 30 0.25 40 to 260/270 1909BD-113

Biodiesel EN14110Residual Methanol

0.32 30 1.8 20 to 260/280 123-BD34

• Specially designed for the determination of trace methanol in B100 using EN14110

• Bonded and cross-linked

• Solvent rinsable

Biodiesel Test Samples

Description Part No.

Biodiesel MSTFA kit, 10 x 1 mL ampoules, N-Methyl-N-(trimethylsilyl)trifluoro- acetamide for ASTM methode D6584

5190-1407

Biodiesel D6584 kit2 internal standard solutions, 1 mL, 5/pk and 2 internal standard solutions, 5 mL

5190-1408

Biodiesel E14105 kit, 4 x 1 mL ampoules4 standard solutions

5190-1409

Biodiesel Monoglyceride kit, 3 x 1 mL ampoules 5190-1410

Page 49: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

266

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Chiral Columns

30% Heptakis (2,3-di-O-methyl-6-O-t-butyldimethylsilyl)-b-cyclodextrin

• 30% heptakis (2,3-di-O-methyl-6-O-t-butyl dimethylsilyl)-b-cyclodextrin in DB-1701

• Chiral separations without chiral specific derivatization

• New stationary phase for improved resolution of many chiral separations

• Ideal for many chiral g-lactones and terpenes

Because CycloSil-B GC columns are not bonded or cross-linked, we do not recommendsolvent rinsing.

Similar Phases: LIPODEX C, Rt-b DEXm, b-DEX 110, b-DEX 120

CycloSil-B Chromatograms

Food, Flavors and Fragrances

Citrus Flavored CarbonatedBeverage (Soda)

Page 405

Rosemary Oil Page 405

CycloSil-B

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 35 to 260/280 112-6632

0.32 30 0.25 35 to 260/280 113-6632

Si OO

O

O

O

O

O O

OO

OO

O

OO

O

O

O

O O O

OO

O

OO

O

O

O

O

O

O

O

O

O

Si

Si

Si

Si

Si

Si

CycloSil-B

Our proven Cyclodex-B, CycloSil-B and HP-Chiral b offer the chiral analyst a broad range of chiral separations. Although no single column resolves every enantiomeric pair, our no-hassle return policy allows you to try the column for your application and if it doesn’t work, simply return it.

Recommendations for choosing a chiral column

• Contact Technical Support through your local Agilent office for a more specific recommendation

• Refer to existing applications and literature

• Choose CycloSil-B as a general purpose column

• Use HP-Chiral b when using a nitrogen specific detector

Chiral Columns

Page 50: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

267

GC and GC/MS

www.agilent.com/chem/supplies

• 10.5% Beta-Cyclodextrin in DB-1701

• Chiral separations without chiral specific derivatization

• Broad range of resolving potential

• Excellent peak shape

Because Cyclodex-B GC columns are not bonded or cross-linked, we do not recommendsolvent rinsing.

Similar Phases: LIPODEX C, Rt-b DEXm, b-DEX 110, b-DEX 120

Cyclodex-B Chromatograms

Food, Flavors and Fragrances

Menthol Page 401

Cyclodex-B

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 50 to 230/250 112-2532

60 0.25 50 to 230/250 112-2562

0.32 30 0.25 50 to 230/250 113-2532

• Beta-cyclodextrin in (35%-Phenyl)-methylpolysiloxane

• Chiral separations without chiral specific derivatization

• Phenyl-based polymer provides low bleed and does not interfere with nitrogen-specific detectors.

• Available in two concentrations of beta-cyclodextrin: 10% and 20%

• 20% beta-cyclodextrin best choice for initial screening

Similar Phases: LIPODEX C, Rt-b DEXm, b-DEX 110, b-DEX 120

HP-Chiral 10bID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 30 to 240/250 19091G-B133

HP-Chiral 20b0.25 30 0.25 30 to 240/250 19091G-B233

0.32 30 0.25 30 to 240/250 19091G-B213

Cyclodex-B

HP-Chiral b

HP-Chiral b Chromatograms

Food, Flavors and Fragrances

Chiral Compounds in Essential Oils andFragrances

Page 401

Chiral Columns

Page 51: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

268

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• 100% Dimethylpolysiloxane

• Non-polar

• Specially processed for extended temperature limit of 400°C

• High temperature, polyimide-coated, fused silica tubing

• Excellent peak shape and faster elution times for high boilers

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: Stx-1ht

DB-1ht

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.10 -60 to 400 122-1111

30 0.10 -60 to 400 122-1131

0.32 15 0.10 -60 to 400 123-1111

30 0.10 -60 to 400 123-1131

High Temperature Columns

DB-1ht

Food and flavor analyses place stringent demands on capillary columns. Samples have manycomponents that are difficult to resolve and column-to-column reproducibility becomes critical.Agilent J&W GC columns are ideal for meeting these needs. Our rigorous quality controlspecifications and extensive QC testing ensure that the column you buy today will perform justlike the column you buy tomorrow.

Recommended Columns for Food, Flavors and Fragrances

• HP-88 for cis- and trans-FAME isomers

• DB-XLB and DB-17ht for triglycerides

• DB-FFAP for organic free fatty acids

• DB-1, DB-WAX for fragrance compounds

• High Efficiency (0.18 mm ID), DB-1, DB-5 or DB-Wax for fast analysis of fragrances and FAMEs

• Highly reproducible and specially tested Microbore (0.1 mm ID) DB-WaxFF for fragrance analysis

• DB-XLB and DB-17ms or DB-XLB and DB-35ms for dual column confirmation of CLPpesticide analysis

• HP-INNOWax or DB-WAXetr for higher temperature polar compound analysis

Food, Flavors and Fragrances Columns

Food, Flavors and Fragrances Columns

Page 52: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

269

GC and GC/MS

www.agilent.com/chem/supplies

High Temperature Columns

• (50%-Phenyl)-methylpolysiloxane

• Mid-polarity

• Extended upper temperature limit of 365°C

• High temperature, polyimide-coated, fused silica tubing

• Excellent peak shape and faster elution times for high boilers

• Improved resolution for triglycerides

• Ideal for confirmational analyses

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: Rtx-65TG, BPX50, CP-TAP CB

DB-17ht Chromatograms

Food, Flavors and Fragrances

Butter Triglycerides II Page 415

DB-17ht

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 5 0.15 40 to 340/365 122-1801

15 0.15 40 to 340/365 122-1811

30 0.15 40 to 340/365 122-1831

0.32 15 0.15 40 to 340/365 123-1811

30 0.15 40 to 340/365 123-1831

60 0.15 40 to 340/365 123-1861

DB-17ht

• (5%-Phenyl)-methylpolysiloxane

• Non-polar

• Specially processed for extended temperature limit of 400°C

• High temperature, polyimide-coated, fused silica tubing

• Excellent peak shape and faster elution times for high boilers

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: HT5, Stx-5ht, VF-5ht

DB-5ht Chromatograms

Food, Flavors and Fragrances

Butter Triglycerides I Page 415

DB-5ht

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.10 -60 to 400 122-5711

30 0.10 -60 to 400 122-5731

0.32 10 0.10 -60 to 400 123-5701

15 0.10 -60 to 400 123-5711

30 0.10 -60 to 400 123-5731

DB-5ht

Page 53: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

270

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Life Sciences Columns

The life sciences offer some difficult challenges to capillary GC chromatographers. These include complex sample matrices, the necessity for low level detection and thechemically active characteristics of many of the samples. In response to this, Agilent offers a line of columns which are designed specifically for drugs of abuse testing.

Recommended Columns for Life Sciences

• DB-ALC1 and DB-ALC2 for U.S. Blood Alcohol analysis

• DB-ALC2 and HP-Blood Alcohol column for European Blood Alcohol analysis

• Low-bleed columns for controlled substances

• DB-35ms for barbiturates

• DB-17ms for hallucinogens

• DB-EVDX for analysis of drugs of abuse

• DB-624, DB-1301, DB-1, DB-WAX, DB-WAXetr or HP-INNOWax for Residual Solvent analysis

• Reliable blood alcohol analysis

• Optimized primary and confirmation column pair for U.S. blood alcohol analysis

• Faster GC run times

• Improved resolution of key ethanol/acetone peaks

• Available in 0.32 and 0.53 mm ID

• Bonded and cross-linked

Similar Phases: Rtx-BAC1, Rtx-BAC2

DB-ALC1 and DB-ALC2Chromatograms

Life Sciences

Blood Alcohols I (Static Headspace/Split)

Page 459

Blood Alcohols II (Static Headspace/Split)

Page 459

Blood Pollutants I Page 460

Blood Pollutants II Page 461

DB-ALC1 and DB-ALC2

Description ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-ALC1 0.32 30 1.80 20 to 260/280 123-9134

DB-ALC1 0.53 30 3.00 20 to 260/280 125-9134

DB-ALC2 0.32 30 1.20 20 to 260/280 123-9234

DB-ALC2 0.53 30 2.00 20 to 260/280 125-9234

Life Sciences Columns

DB-ALC1 and DB-ALC2

Page 54: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

271

GC and GC/MS

www.agilent.com/chem/supplies

• Reliable blood alcohol analysis

• Excellent confirmation column with DB-ALC2 for method using t-butanol as internal standard

HP-Blood Alcohol

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 7.5 20.00 -60 to 270/290 19091S-510

• Specially configured and tested for drugs of abuse confirmation

• Drug test mix included: caffenine, gluthethimide, lidocaine, phenobarbital, EDDP,methaqualone, methadone, cocaine, desiprmine, carbamazepine

• DB-5ms EVDX is equivalent to (5%-Phenyl)-methylpolysiloxane

• Consistent retention and peak shape

• Low bleed for GC/MS analysis

• Bonded and cross-linked

• Solvent rinsable

DB-EVDX Chromatograms

Life Sciences

Anesthetics Page 450

Sedative Hypnotics Page 455

DB-EVDX

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.33 -60 to 325/350 128-8522

HP-Blood Alcohol

DB-5ms EVDX

• Equivalent to USP Phase G43

• Thinner film reduces run time by 2.5 times and increases Minimum Detection Limit (MDL)by 2 times compared to standard film thickness used for this method

• Bonded and cross-linked

Similar Phases: DB-624, PE-624, 007-624, 007-502, CP-624, ZB-624

HP-Fast Residual Solvent

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 30 1.00 -20 to 260 19095V-420

HP-Fast Residual Solvent

Life Sciences Columns

Page 55: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

272

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Pesticides Columns

• Non-polar

• Specifically designed and processed for the analysis of organochlorine pesticides

• ECD tested to assure minimal pesticide breakdown and low ECD bleed

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: DB-5, Ultra-2, SPB-5, CP-Sil 8CB, RSL-200, Rtx-5, BP-5, CB-5, OV-5, 007-2(MPS-5), SE-52, SE-54, XTI-5, PTE-5, HP-5MS, CC-5, ZB-5

HP-PAS5

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 25 0.52 -60 to 325/350 19091S-010

Agilent J&W low bleed columns are ideal for the analysis of pesticides. Not only do theypossess less bleed than a standard polymer, which improves the signal to noise ratio andminimum detectable quantities, but they also have higher upper temperature limits whichallow for faster run times. Agilent also offers several common phases with additional pesticidespecific testing to ensure performance for your application.

Recommended Columns for Pesticides

Pesticides Columns

HP-PAS5

• DB-35ms (P/N 123-3832) and DB-XLB (P/N 122-1236) for CLP pesticides, chlorinated herbicides, and EPA Method 508.1 pesticides

• High efficiency 0.18 mm ID DB-17ms (P/N 121-4722) and DB-XLB (P/N 121-1222) for faster analysis

• Also ideal for other dual ECD applications such as 8082 PCBs (Aroclors) and haloacetic acids

• DB-5ms (P/N 122-5532) and DB-35ms (P/N 122-3832) for organophosphorous pesticides(EPA Method 8141A)

• HP-5ms for over 550 pesticides using retention time locking software and database

Page 56: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

273

GC and GC/MS

www.agilent.com/chem/supplies

• Low/mid-polarity

• Exact replacement of HP-PAS1701

• Specifically designed and processed for the analysis of organochlorine pesticides

• ECD tested to assure minimal pesticide breakdown and low ECD bleed

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: SPB-1701, CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, 007-1701

DB-1701P

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 -20 to 280/300 122-7732

0.32 25 0.25 -20 to 280/300 123-7722

30 0.25 -20 to 280/300 123-7732

0.53 30 1.00 -20 to 260/280 125-7732

DB-1701P

• Specifically designed for the analysis of chlorinated pesticides and PCBs

• U.S. EPA Methods: 608, 508, 8080

• Excellent inertness and recoveries without pesticide breakdown

• Bonded and cross-linked

• Solvent rinsable

• Exact replacement of HP-608

Similar Phases: SPB-608, NON-PAKD Pesticide, 007-608

DB-608 Chromatograms

Environmental

Organochlorine Pesticides II Page 366

DB-608

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 40 to 280/300 121-6822

0.25 30 0.25 40 to 280/300 122-6832

0.32 30 0.50 40 to 280/300 123-1730

0.45 30 0.70 40 to 260/280 124-1730

0.53 15 0.83 40 to 260/280 125-1710

30 0.50 40 to 260/280 125-6837

0.83 40 to 260/280 125-1730

DB-608

Pesticides Columns

Page 57: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

274

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Petroleum applications vary greatly in character. From the noble gases to simulated distillation, Agilent offers a broad range of columns designed to meet the needs of thepetroleum/petrochemical chromatographer. Refer to the PLOT column section for columns for the analysis of light gases.

Recommended Columns for Petroleum

• DB-HT SimDis for Simulated Distallation

• HP-PONA, DB-5 or HP-1 for PONA and PIANO analysis

• 100% Dimethylpolysiloxane

• Specifically designed for simulated distillation using ASTM Method D2887

• Rapid conditioning, fast run time and low bleed when compared to packed columns

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: HP-1, Petrocol EX2887, MXT-2887, MXT-1, Rtx-2887

DB-2887 Chromatograms

Petroleum

Reference Gas Oil Page 483

Simulated Distillation Page 483

DB-2887

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 10 3.00 -60 to 350 125-2814

Petroleum Columns

DB-2887

Petroleum Columns

Tips & Tools

Agilent offers a line of columns which are purposely designed and applicationoptimized for the analysis of biodiesel to meet ASTM and CEN testing standards.

Turn to pages 264–265.

Page 58: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

275

GC and GC/MS

www.agilent.com/chem/supplies

• 100% dimethylpolysiloxane

• “Boiling point” phase for high temperature simulated distillation

• Durable stainless steel tubing

• 430ºC upper temperature limit

• Distillation range of C6 to C110+

• Low bleed – even at 430ºC

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: Petrocol EX2887, CP-SimDist Ultimetal, MXT-2887, Rtx-2887, AC ControlsHigh Temp Sim Dist, AT-2887

DB-HT SimDis

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 5 0.15 -60 to 400/430 145-1001

DB-HT SimDis

• 100% Dimethylpolysiloxane

• Configured for the analysis of petroleum process products

• Tested to ensure the resolution of m-xylene from p-xylene and of cyclopentane from 2,3-dimethylbutane

• PONA, PIANO

• High resolution

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: Petrocol DH, SPB-1, 007-1, Rtx-1, MXT-1, Rtx-1PONA

Note: 100 psi regulator required to reach optimum carrier gas velocity

HP-PONA Chromatograms

Petroleum

Refinery Gas, HP-PONA Page 473

Sulfur Compounds in Naphtha

Page 478

HP-PONA

Description ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

HP-PONA 0.20 50 0.50 -60 to 325/350 19091S-001

HP-1 0.20 50 0.50 -60 to 325/350 19091Z-205

HP-1 0.25 100 0.50 -60 to 325/350 19091Z-530

HP-PONA

DB-HT SimDis Chromatograms

Petroleum

n-Paraffin Standard Page 485

Petroleum Columns

Page 59: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

276

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• 100% Dimethylpolysiloxane

• Configured for the analysis of petroleum process products

• PONA, PIANO

• High resolution

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: Petrocol DH, HP-PONA, SPB-1, 007-1, Rtx-1, MXT-1

Note: 100 psi regulator required to reach optimum carrier gas velocity

DB-Petro Chromatograms

Petroleum

Regular Unleaded Gasoline(California Phase 1) - "Normal" GC Run I

Page 484

Unleaded Gasoline Page 481

PONA Mix as Specified by AFNOR Method #2

Page 482

DB-Petro

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 50 0.50 -60 to 325/350 128-1056

0.25 100 0.50 -60 to 325/350 122-10A6

DB-Petro

HP-1 Aluminum Clad

• 100% dimethylpolysiloxane

• Aluminum clad fused silica tubing

• For high temperature simulated distillation

• Bonded and cross-linked

• Solvent rinsable

HP-1 Aluminum Clad

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 5 0.09 0 to 350/450 19095S-205

10 0.09 0 to 350/450 19095S-200

Petroleum Columns

For optimum performance, ferrules should be replaced everytime the column is replaced andduring column maintenance.

Turn to page 158.

Page 60: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

277

GC and GC/MS

www.agilent.com/chem/supplies

Recommended Columns for Semivolatiles

• HP-5ms, DB-5.625, DB-5ms Ultra Inert, HP-5ms Ultra Inert for EPA methods 8270 and 525

• DB-XLB for PCB congeners

• HP-5ms, DB-5ms Ultra Inert, HP-5ms Ultra Inert or DB-35ms for PAHs

• DB-5ms, DB-5ms Ultra Inert or DB-XLB for phenols

Semivolatiles are usually extracted from soil samples or other environmental matrices. GCcolumns with precise retention time reproducibility and good mass spectrometer performanceare key enablers for these often demanding analyses.

• Specifically engineered for the analysis of polychlorinated dibenzodioxins (PCDDs) and dibenzofurans (PCDFs)

• Resolves 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in one run

• Low bleed

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: SP-2331, 007-23, Rtx-2332, CP-Sil 88, Rtx-Dioxin

Note: 100 psi regulator required to reach optimum carrier gas velocity

DB-Dioxin Chromatograms

Environmental

Dioxins and Furans Page 376

DB-Dioxin

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 60 0.15 40 to 250/270 122-2461

0.25 40 to 250/270 122-2462

Semivolatiles Columns

DB-Dioxin

Semivolatiles Columns

Page 61: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

278

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• Close equivalent to a (5%-Phenyl)-methylpolysiloxane

• Non-polar

• Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols*

• Surpasses EPA performance criteria for semivolatiles

• Inert for base, neutral and acidic compounds

• High temperature limit with excellent thermal stability and low bleed

• Bonded and cross-linked

• Solvent rinsable

* Pentachlorophenol, 2,4-Dinitrophenol, Carbazole, and N-Nitrosodiphenylamine used to testresponse factors.

Similar Phases: XTI-5, Rtx-5, PTE-5, BPX-5

DB-5.625

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 121-5621

0.36 -60 to 325/350 121-5622

0.25 30 0.25 -60 to 325/350 122-5631

0.50 -60 to 325/350 122-5632

1.00 -60 to 325/350 122-5633

60 0.25 -60 to 325/350 122-5661

0.32 30 0.25 -60 to 325/350 123-5631

0.50 -60 to 325/350 123-5632

DB-5.625

DB-5.625 Chromatograms

Environmental

Analysis of Semivolatiles Page 373

European Red List Volatiles Page 391

Semivolatiles Columns

HP-5ms Semivolatile

• (5%-Phenyl)-methylpolysiloxane, identical selectivity to HP-5

• Non-polar

• Very low bleed characteristics, ideal for GC/MS

• Specifically tested for inertness for active compounds including acidic and basic compounds

• Improved signal-to-noise ratio for better sensitivity and mass spectral integrity

• Bonded and cross-linked

• Solvent rinsable

• Equivalent to USP Phase G27

HP-5ms Semivolatile

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.50 -60 to 325/350 19091S-139

Page 62: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

279

GC and GC/MS

www.agilent.com/chem/supplies

Volatiles Columns

• Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods 502.2, 524.2 and 8260

• 0.45 mm ID columns provide more plates per meter compared to 0.53 mm ID columns for the fewest coelutions for GC method (an industry first)**

• No subambient cooling required to resolve the six “gases”

• Fast run time:

• < 30 minutes for optimum sample throughput

• < 8 minutes with 0.18 mm ID

• Low polarity

• Excellent peak shape

• Bonded and cross-linked

• Solvent rinsable

**Two coelutions: 1) m- and p-xylene, for which U.S. EPA does not require separation, and 2) 1,1,2,2-tetrachloroethane and o-xylene which are separated by detectors PID and ELCD,respectively. Note to GC/MS analysts: These coeluting compounds have different primarycharacteristic ions of 83 and 106, respectively.

Similar Phases: VOCOL, NON-PAKD, Rtx-Volatiles, PE-Volatiles, 007-624, HP-624, CP-624,Rtx-VRX, Rtx-VGC

DB-VRX Chromatograms

Environmental

EPA Volatiles by GC/MS (Split Injector)

Page 387

High Speed VOC, EPA Method 8260

Page 388

Unleaded Gasoline Page 359

Extended Analyte List for EPA Method 8021

Page 389

DB-VRX

Recommended Columns for Volatiles

• DB-VRX and DB-624 for EPA methods 502.2 and 8021

• DB-VRX (60 m, 0.25 mm ID) for GC/MS volatiles methods

• DB-VRX (20 m, 0.18 mm ID) for fast GC/MS volatiles analysis using a 5973 MSD (Not recommended for Ion Trap MS or older MSDs)

• DB-MTBE for extended EPA method 8020

• DB-TPH for the analysis of BTEX and gasoline total petroleum hydrocarbons

• DB-624 (20 m, 0.18 mm ID) for fast GC/MS volatiles analysis

Agilent offers a selection of advanced polymer chemistries for the increasingly demandingvolatiles applications. Whether for a primary analytical column or as a complementaryconfirmation column, Agilent J&W capillaries are chromatographers' first choice.

Volatiles Columns

Page 63: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

280

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Volatiles Columns

• Specifically designed for the analysis of volatile priority pollutants

• No cryogenics needed for U.S. EPA Method 502.2

• Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, 8260

• Excellent inertness for active compounds

• Bonded and cross-linked

• Solvent rinsable

• Exact replacement of HP-624

• Equivalent to USP Phase G43

Similar Phases: AT-624, Rtx-624, PE-624, 007-624, 007-502, CP-624, ZB-624, VF-624ms

DB-624 Chromatograms

Environmental

EPA Volatiles by GC/MS II(Split Injector)

Page 387

European Red List Volatiles Page 391

Extended Analyte List forEPA Method 8021

Page 389

Fast VOC Analysis Page 390

Food, Flavors and Fragrances

Fusel Oil Standard & Brandy Sample

Page 397

Industrial Chemicals

Alcohols I Page 416

Esters II Page 429

Ethers Page 430

Glycols II Page 431

Halogenated Hydrocarbons I Page 434

Nitrogen Based Solvents II Page 440

Life Sciences

Residual Solvents, DMI Diluent

Page 462

Residual Solvents, USP 467 Page 461

Petroleum

1,3-Butadiene Page 469

DB-624

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 1.00 -20 to 280 121-1324

0.20 25 1.12 -20 to 260 128-1324

0.25 30 1.40 -20 to 260 122-1334

60 1.40 -20 to 260 122-1364

0.32 30 1.80 -20 to 260 123-1334

60 1.80 -20 to 260 123-1364

0.45 30 2.55 -20 to 260 124-1334

75 2.55 -20 to 260 124-1374

0.53 30 3.00 -20 to 260 125-1334

60 3.00 -20 to 260 125-1364

75 3.00 -20 to 260 125-1374

DB-624

DB-VRX

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 1.00 -10 to 260 121-1524

40 1.00 -10 to 260 121-1544

0.25 30 1.40 -10 to 260 122-1534

60 1.40 -10 to 260 122-1564

0.32 30 1.80 -10 to 260 123-1534

60 1.80 -10 to 260 123-1564

0.45 30 2.55 -10 to 260 124-1534

75 2.55 -10 to 260 124-1574

Page 64: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

281

GC and GC/MS

www.agilent.com/chem/supplies

Volatiles Columns

• Selectivity engineered for: U.S. EPA Methods 502.2, 524.2 and 8260

• Low polarity – slightly more polar than DB-VRX

• Excellent peak shape

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: DB-VRX, NON-PAKD, Rtx-Volatiles, PE-Volatiles, 007-624, HP-624, CP-624,Rtx-VRX, Rtx-VGC

HP-VOC

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 30 1.10 -60 to 280/290 19091R-303

60 1.10 -60 to 280/290 19091R-306

0.32 60 1.80 -60 to 280/290 19091R-316

90 1.80 -60 to 280/290 19091R-319

0.53 90 3.00 -60 to 280/290 19095R-429

105 3.00 -60 to 280/290 19095R-420

• Available in 105 meters for volatiles analyses

• Excellent peak shape

• Bonded and cross-linked

• Solvent rinsable

Similar Phases: Rtx-502.2, VOCOL, HP-VOC

DB-502.2

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 60 1.80 0 to 260/280 123-1464

0.53 105 3.00 0 to 260/280 125-14A4

HP-VOC

DB-502.2

Page 65: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

282

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• Specifically designed for the analysis of total petroleum hydrocarbons (TPHs), soil analysis,and LUFT

• Three analyses in one injection – gas range organics, diesel range organics and motor oil

• Fast run time

• Bonded and cross-linked

• Solvent rinsable

DB-TPH

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 0.25 -10 to 320 123-1632

• Low polarity stationary phase

• Resolves MTBE from 2-methylpentane and 3-methylpentane for better quantitation

• Engineered for purge and trap injection without the need for cryofocusing

• Bonded and cross-linked

• Solvent rinsable

DB-MTBE

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.45 30 2.55 35 to 260/280 124-0034

0.53 30 3.00 35 to 260/280 125-0034

DB-MTBE Chromatograms

Environmental

Methyl Tert-Butyl Ether(MTBE) FID, Extended 8020 Analysis

Page 359

DB-MTBE

DB-TPH

Volatiles Columns

Tips & Tools

For a precision cut on yourcapillary column, use Agilent'sGC column cutting tool (partnumber 5183-4620).

Page 66: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

283

GC and GC/MS

www.agilent.com/chem/supplies

PLOT Columns

PLOT Columns

PLOT columns are ideal for separating compounds that are gases at room temperatures. Agilent Technologies offers a comprehensive line ofPLOT columns for analysis of fixed gases, low molecular weight hydrocarbon isomers, volatile polar compounds and reactive analytes such assulfur gases, amines and hydrides. Our PLOT phases are offered in dimensions from 0.25 to 0.53 mm ID, allowing for easy column selectionfor various detector and system requirements. For GC/MS systems, we offer several small diameter columns with truly bonded andimmobilized stationary phases, eliminating potential detector fouling due to particle generation.

PLOT Column Application Recommendations

Column Stationary Phase Typical Applications

HP-PLOT Molesieve 5Å molecular sieve zeolite Permanent and noble gases. Thick and thin films available. Thick film column will resolve argon and oxygen at 35°C.

HP-PLOT Al203 KCl Aluminum oxide deactivated with KCl Least "polar" Alumina phase. Lowest retention of olefins relative to comparable paraffin. C1 to C8 hydrocarbon isomers. Column ofchoice for accurate quantitation of dienes, especially propadiene and butadiene from ethylene and propylene streams.

HP-PLOT Al203 S Aluminum oxide deactivated with sodium sulfate Excellent general use Alumina column for light hydrocarbons: C1 to C8 isomers. Best for resolving acetylene from butane and propylene from isobutane.

GS-Alumina Aluminum oxide with proprietary deactivation Most "polar" of the Alumina columns. Highest retention of olefinsrelative to comparable paraffin. Excellent general use Aluminacolumn for light hydrocarbons: C1 to C8 isomers. Best for resolvingcyclopropane from propylene. Good stability and recovery from water saturation.

HP-PLOT Q Polystyrene-divinylbenzene C1 to C3 isomers, alkanes to C12, CO2, methane, air/CO, water, oxygenated compounds, sulfur compounds, solvents.

HP-PLOT U Divinylbenzene/ethylene More polar than HP-PLOT Q and GS-Q. C1 to C7 hydrocarbons,CO2, methane, air/CO, water, glycol dimethacrylate oxygenates,amines, solvents, alcohols, ketones, aldehydes.

GS-GasPro Proprietary, bonded silica-based C1 to C12 hydrocarbons, CO2, trace-level sulfurs, hydride gases,inorganic gases, halocarbons, SF6, oxygen/nitrogen separation at -80°C.

GS-CarbonPLOT Bonded, monolithic carbon layer C1 to C5 hydrocarbons, CO2, air/CO, trace acetylene in ethylene, methane.

GS-OxyPLOT Proprietary high selectivity adsorbent High retention for oxygenated hydrocarbons (Methanol retentionindex +1400). Useful for alcohols, ketones, and ethers in gasoline,diesel, and C1 to C4 hydrocarbon streams.

Page 67: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

284

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

PLOT Columns

Similar Phases: CP-LowOX

GS-OxyPLOT

ID (mm) Length (m) Temp Limits (°C) Part No.

0.53 10 350 115-4912

• Least "polar" Alumina phase

• Aluminum oxide deactivated with KCl

• Standard column choice for light hydrocarbon analysis – C1 to C8 hydrocarbon isomers

• Low retention of olefins relative to comparable paraffin

• Excellent for quantitation of dienes, especially propadiene and butadiene from ethylene and propylene streams

• Recommended phase for many ASTM methods

• Preferred KCl deactivated Alumina

Similar Phases: CP-Al2O3/KCl PLOT, Rt-Alumina PLOT, Alumina PLOT, Al2O3/KCl

HP-PLOT Al2O3 KCl

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 5.00 -60 to 200 19091P-K33

0.32 50 8.00 -60 to 200 19091P-K15

0.53 30 15.00 -60 to 200 19095P-K23

50 15.00 -60 to 200 19095P-K25

GS-OxyPLOT

HP-PLOT Al2O3 KCl

GS-OxyPLOT Chromatograms

Petroleum

Selected Oxygenates Page 465

Trace Oxygenates in LightHydrocarbon Matrices

Page 465

Oxygenates Page 480

• Accurate analysis of ppm/ppb level oxygenates in C1 to C10 hydrocarbons

• Strong selectivity for a wide range of oxygenates (ethers, alcohols, aldehydes, and ketones)in complex matrices such as gaseous hydrocarbons, motor fuels, and crude oil

• Suitable for ASTM methods for oxygenates

• Very high column stability (upper temperature limit of 350°C) with no column bleed

• Stable phase coating virtually eliminating particle generation and detector spiking

• Excellent for low concentration, quantitative GC analysis

• Ideal for selective heart-cutting applications

Page 68: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

285

GC and GC/MS

www.agilent.com/chem/supplies

PLOT Columns

• Least "polar" Alumina phase

• Aluminum oxide deactivated with KCl

• Good choice for light hydrocarbon analysis

• Good resolution of propadiene and butadiene from ethylene and propylene streams

Similar Phases: CP-Al2O3/KCl PLOT, Rt-Alumina PLOT, Alumina PLOT, Al2O3/KCl

GS-Alumina KCl Chromatograms

Petroleum

Impurities in Ethylene Page 468

Impurities in Propylene Page 468

GS-Alumina KCl

ID (mm) Length (m) Temp Limits (°C) Part No.

0.53 30 -60 to 200 115-3332

50 -60 to 200 115-3352

• Middle range of "polarity" for Alumina phases

• Aluminum oxide deactivated with sodium sulfate

• Excellent general use column for light hydrocarbon analysis – C1 to C8 hydrocarbon isomers

• Best for resolving acetylene from butane and propylene from isobutane

Similar Phases: GS-Alumina

HP-PLOT Al2O3 S Chromatograms

Petroleum

Ethylene Page 467

Natural Gas Page 467

Refinery Gas III Page 474HP-PLOT Al2O3 S

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 5.00 -60 to 200 19091P-S33

0.32 25 8.00 -60 to 200 19091P-S12

50 8.00 -60 to 200 19091P-S15

0.53 15 15.00 -60 to 200 19095P-S21

30 15.00 -60 to 200 19095P-S23

50 15.00 -60 to 200 19095P-S25

GS-Alumina KCl

HP-PLOT Al2O3 S

Page 69: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

286

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

PLOT Columns

• Most "polar" Alumina phase

• Aluminum oxide with proprietary deactivation

• Excellent general use column for light hydrocarbon analysis – C1 to C8 hydrocarbon isomers

• Separates C1 to C4 saturated and unsaturated hydrocarbons

• Best for resolving cyclopropane from propylene

• Faster, more efficient and provides more sensitivity than packed equivalents

• Minimal conditioning time required

• Preferred substitution for sodium sulfate deactivated Alumina because of its regenerative nature

Similar Phases: Al2O3/KCl, Al2O3/Na2SO4, Rt-Alumina PLOT, Alumina PLOT

Note: Alumina columns have a tendency to adsorb water and CO2 which, over time, results inchanges in retention time. We use an advanced, proprietary deactivation process whichallows for rapid regeneration. Fully water saturated GS-Alumina columns regenerate in 7hours or less at 200ºC.

GS-Alumina Chromatograms

Petroleum

1,3-Butadiene Purity Page 470

Extended HydrocarbonAnalysis I

Page 471

Propylene Page 469

GS-Alumina

ID (mm) Length (m) Temp Limits (°C) Part No.

0.53 30 -60 to 200 115-3532

50 -60 to 200 115-3552

GS-Alumina

• Most "polar" Alumina phase (similar to GS-Alumina)

• Aluminum oxide deactivated with proprietary deactivation

• Good general use column for light hydrocarbon analysis – C1 to C8 hydrocarbon isomers

• Good for resolving acetylene from butane and propylene from isobutane

Similar Phases: GS-Alumina

HP-PLOT Al2O3 M

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 50 8.00 -60 to 200 19091P-M15

0.53 30 15.00 -60 to 200 19095P-M23

50 15.00 -60 to 200 19095P-M25

HP-PLOT Al2O3 M

Page 70: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

287

GC and GC/MS

www.agilent.com/chem/supplies

PLOT Columns

• Unique bonded silica PLOT column technology

• Excellent choice for light hydrocarbons and sulfur gases

• Retention stability not affected by water

• Separates CO and CO2 on a single column

• Ideal PLOT column for GC/MS – no particles

Similar Phases: CP-Silica PLOT

GS-GasPro Chromatograms

Environmental

C1 and C2 Halocarbons(Freons)

Page 395

Industrial Chemicals

Halocarbons Page 444

Halothane Page 445

Inorganic Gases Page 446

Petroleum

Extended HydrocarbonAnalysis II

Page 472

Mercaptans Page 477

Sulfur Compounds inPropylene (1 ppm)

Page 477

Sulfur Gas Analysis in LightHydrocarbon Streams I

Page 475

GS-GasPro

ID (mm) Length (m) Temp Limits (°C) Part No.

0.32 5 -80 to 260/300 113-4302

15 -80 to 260/300 113-4312

30 -80 to 260/300 113-4332

60 -80 to 260/300 113-4362

GS-GasPro

• High stability, bonded carbon layer stationary phase

• Unique selectivity for inorganic and organic gases

• Extended temperature limit of 360ºC

• Ideal for GC/MS – no particle generation

• Retention stability not affected by water

Similar Phases: Carbopack, CLOT, Carboxen-1006 PLOT, CP-CarboPLOT P7

GS-CarbonPLOT Chromatograms

Environmental

N2O III Page 396

GS-CarbonPLOT

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 15 1.50 0 to 360 113-3112

30 1.50 0 to 360 113-3132

3.00 0 to 360 113-3133

60 1.50 0 to 360 113-3162

0.53 15 3.00 0 to 360 115-3113

30 3.00 0 to 360 115-3133

GS-CarbonPLOT

Page 71: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

288

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

PLOT Columns

• A PLOT column for the analysis of permanent gases

• O2, N2, CO and CH4 resolve in less than 5 minutes

• Durable molecular sieve 5Å coating minimizes baseline spiking and damage to multiport valves

• Select a thick film for Ar/O2 separation without cryogenic cooling

• Select thin film HP-PLOT Molesieve columns for routine air monitoring applications

• Replaces GS-Molesieve

Note: Molecular sieve columns will absorb water which, over time, results in changes in retention time. We use an advanced, proprietary deactivation process which allows forrapid regeneration. Fully saturated HP-PLOT Molesieve columns regenerate in 7 hours or less at 200ºC.

HP-PLOT MolesieveChromatograms

Environmental

N2O II Page 396

Petroleum

Noble Gases Page 466

Permanent Gases Page 466

HP-PLOT Molesieve

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 15 25.00 -60 to 300 19091P-MS7

30 12.00 -60 to 300 19091P-MS4

25.00 -60 to 300 19091P-MS8

0.53 15 25.00 -60 to 300 19095P-MS5

50.00 -60 to 300 19095P-MS9

30 25.00 -60 to 300 19095P-MS6

50.00 -60 to 300 19095P-MS0

HP-PLOT Molesieve

Page 72: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

289

GC and GC/MS

www.agilent.com/chem/supplies

PLOT Columns

Similar Phases: CP PoraPLOT Q, CP PoraPLOT Q-HT, Rt-QPLOT, SupelQ PLOT, GS-Q

HP-PLOT Q Chromatograms

Environmental

N2O I Page 396

Petroleum

Baseline Resolution ofAir/CO, CO2, and Methanein a Natural Gas Sample

Page 466

Ethylene Oxide SyntheticStandard

Page 479

Oxygenates Page 480

Refinery Gas I Page 473 HP-PLOT Q

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 15 20.00 -60 to 270/290 19091P-QO3

30 20.00 -60 to 270/290 19091P-QO4

0.53 15 40.00 -60 to 270/290 19095P-QO3

30 40.00 -60 to 270/290 19095P-QO4

Though highly stabilized, it is impossible to guarantee that no particles will dislodge from thecolumn wall. When used in valve-switching applications, the use of a particle trap can preventscarring of the rotors.

Particle Traps for Use with PLOT Columns

ID (mm) Length (m) Part No.

0.32 2.5 5181-3351

0.53 2.5 5181-3352

HP-PLOT Q

Particle Traps for Use with PLOT Columns

• Bonded polystyrene-divinylbenzene based column

• A PLOT column with polarity between Porapak-Q and Porapak-N

• Excellent column for C1 to C3 isomers and Alkanes to C12, CO2, methane, air/CO,oxygenated compounds, sulfur compounds and solvents

• A PLOT column to replace packed gas-solid columns

• Separates ethane, ethylene and ethyne (acetylene)

• Improved resolution in less time than conventional packed columns

• Minimal conditioning time required – 1 hour

• Preferred "Q" column due to its robust nature

Page 73: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

290

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• Porous divinylbenzene homopolymer

• A PLOT column with polarity between Porapak-Q and Porapak-N

• Separates ethane, ethylene and ethyne (acetylene)

• Not recommended for quantification of polar compounds

• Minimal conditioning time required – 1 hour

Similar Phases: CP PoraPLOT Q, CP PoraPLOT Q-HT, Rt-QPLOT, SupelQ PLOT, HP-Q PLOT

GS-Q Chromatograms

Petroleum

Sulfur Gas Analysis in LightHydrocarbon Streams II

Page 476

GS-Q

ID (mm) Length (m) Temp Limits (°C) Part No.

0.32 30 -60 to 250 113-3432

0.53 10 -60 to 250 115-34H2

15 -60 to 250 115-3412

25 -60 to 250 115-3422

30 -60 to 250 115-3432

• Bonded divinylbenzene/ethylene glycol dimethacrylate

• More polar than HP-PLOT Q

• Excellent column for C1 to C7 hydrocarbons, CO2, methane, air/CO, water, oxygenates,amines, solvents, alcohols, ketones, and aldehydes

• Improved resolution in less time than conventional packed columns

Similar Phases: PoraPlot U, RTU PLOT

HP-PLOT U

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 10 -60 to 190 19091P-UO4

0.53 15 20 -60 to 190 19095P-UO3

30 20 -60 to 190 19095P-UO4

GS-Q

HP-PLOT U

PLOT Columns

Page 74: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

291

GC and GC/MS

www.agilent.com/chem/supplies

Metal Columns

Metal Columns

• Excellent inertness

• Virtually unbreakable

• Available in a wide variety of stationary phases

• Bonded and cross-linked

• Ideal for high temperature analysis and process applications

Our easy to handle DB-ProSteel metal columns are deactivated with a new formula (this is notglass lined steel) to provide inertness which truly rivals fused silica. DB-ProSteel metalcolumns can be custom wound upon request for small GC ovens. Several of our most popularbonded phases are available in metal.

DB-ProSteel GC columns have the same outer diameter as standard Megabore (0.53 mm ID),so no special ferrules are required.

DB-ProSteel

Phase ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-PS2887 0.53 10 3.00 -60 to 350 145-2814

DB-PS1 0.53 15 0.15 -60 to 340/360 145-1011

DB-PSWAX 0.53 30 1.00 20 to 230/240 145-7032

DB-PS624 0.53 30 3.00 -20 to 260 145-1334

DB-ProSteel

Tips & Tools

Visit our online Chromatogram Library at www.agilent.com/chem/libraryfor a comprehensive listing of chromatograms searchable by compound name.

Page 75: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

292

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

Whenever possible Agilent recommends the use of bonded and cross-linked polymers.Bonded polymers are more rugged, will have longer lifetimes and can be solvent rinsed.However, Agilent recognizes that some methods have been developed on these non-bondedphases and therefore maintains these columns to support established methods.

• 100% Dimethylpolysiloxane

Similar Phases: OV-101, SP 200, DB-1, HP-1

Because HP-101 columns are not bonded or cross-linked, we do not recommend solventrinsing.

• 50% Phenyl and 50% Methyl siloxane

Similar Phases: OV-17, SP-2250, DB-17, HP-50+

Because the HP-17 is not bonded or cross-linked, we do not recommend solvent rinsing.

HP-17

ID (mm) Length (m) Film (µm)

HP-101

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.20 -60 to 280 19091Y-102

0.32 25 0.30 -60 to 280 19091Y-012

50 0.30 -60 to 280 19091Y-015

Temp Limits (°C) Part No.

0.53 10 2.00 25 to 260/280 19095L-121

Non-Bonded Stationary Phases

HP-101

HP-17

Non-Bonded Stationary Phases

Page 76: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

293

GC and GC/MS

www.agilent.com/chem/supplies

Non-Bonded Stationary Phases

• Base deactivated polyethylene glycol

• Specifically designed for amine analysis

• Excellent peak shape for primary amines

• Replaces HP-Basicwax

Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing.

CAM Chromatograms

Industrial Chemicals

Amines in Water Page 422

Primary Amines Page 420

CAM

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.25 60 to 220/240 112-2112

30 0.25 60 to 220/240 112-2132

0.50 60 to 220/240 112-2133

60 0.25 60 to 220/240 112-2162

0.32 30 0.25 60 to 220/240 113-2132

0.50 60 to 220/240 113-2133

0.53 30 1.00 60 to 200/220 115-2132

Similar Phases: Stabilwax-DB, Carbowax Amine

CAM

• Polyethylene glycol, MW 20,000

• Equivalent to USP Phase G16

Similar Phases: DB-WAX, HP-INNOWax, DB-WAXetr

Because the Carbowax 20M and the HP-20M are not bonded or cross-linked, we do notrecommend solvent rinsing. DB-WAX is the recommended bonded alternate for the HP-20M.

Carbowax 20M

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 60 to 220/240 112-2032

0.32 30 0.25 60 to 220/240 113-2032

HP-20M

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.10 60 to 220 19091W-102

50 0.10 60 to 220 19091W-105

0.32 25 0.30 60 to 220 19091W-012

50 0.30 60 to 220 19091W-015

0.53 10 1.33 60 to 220 19095W-121

30 1.33 60 to 220 19095W-123

Carbowax 20M and HP-20M

Page 77: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

294

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

• DX-1: 90% Dimethylpolysiloxane - 10% Polyethylene Glycol

• DX-4: 15% Dimethylpolysiloxane - 85% Polyethylene Glycol

Because DX series GC columns are not bonded and cross-linked, we do not recommendsolvent rinsing.

DX-1

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 1.00 50 to 250/270 123-6133

DX-4

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 50 to 250/270 122-6432

60 0.25 50 to 250/270 122-6462

0.32 15 0.25 50 to 250/270 123-6412

30 0.25 50 to 250/270 123-6432

60 0.25 50 to 250/270 123-6462

• SE-30: 100% Dimethylpolysiloxane

• SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane

Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing.

SE-30

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 0.25 0 to 325/350 113-3032

SE-54

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 0 to 325/350 112-5432

60 0.25 0 to 325/350 112-5462

0.32 30 0.25 0 to 325/350 113-5432

DX-1 and DX-4

SE-30 and SE-54

Non-Bonded Stationary Phases

Page 78: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

295

GC and GC/MS

www.agilent.com/chem/supplies

Custom GC Column Ordering

Even though we offer over a thousand readily available columns, Agilent recognizes thatsometimes you need something a little out of the ordinary. That's why we developed ourCustom Column Shop. If you can't find what you're looking for in our standard order guides,we will design, build, and test capillary GC columns to meet your needs.

• We can create columns with non-standard lengths or unusual film thickness.

• We can connect columns together in series or as dual columns.

• We recognize that sometimes customers have specific column performance requirementsfor their applications that might not be met with standard test mixes. As a result we canalso custom-test your columns with your desired test mixture and test conditions to meetyour specific performance requirements.

• We can create DuraGuard columns with an integrated guard column. Most phases can bemanufactured with a built-in guard column which means you get the advantages of a guardcolumn without the union. Only available in DB-phases.

Custom columns are ordered under the part number 100-2000. Be sure to provide the detailsof your desired custom service or column including phase, length, ID, and film thickness.

Contact your local Agilent office of your Authorized Agilent Distributor to receive a quote foryour custom column needs. You can find order forms in the back of the catalog.

Customers in the United States, Canada, and Puerto Rico can request a Custom Column Quoteonline at www.agilent.com/chem/CustomColumn.

Custom GC Columns

Page 79: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

296

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

5 in. Cage Columns

Columns for the 6850 GC

GC capillary columns are typically wound on 7 inch cages that fit into "standard-sized" GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. The 5 inch cage configurations listed here are available as standard products.

If you require a column for your 6850 that is not listed below, simply order part number 100-2000 and specify:

• The standard cage part number, on 5 inch cage, or

• The phase and dimensions (length, internal diameter, film thickness), on 5 inch cage

The price of the 5 inch cage column will be the same as the same column on a standard cage.

CAM, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 0.25 60 to 220/240 113-2132E

0.50 60 to 220/240 113-2133E

Cyclodex-B, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 50 to 230/250 112-2532E

0.32 30 0.25 50 to 230/250 113-2532E

Page 80: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

297

GC and GC/MS

www.agilent.com/chem/supplies

DB-1, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 10 0.10 -60 to 325/350 127-1012E

0.40 -60 to 325/350 127-1013E

20 0.10 -60 to 325/350 127-1022E

0.40 -60 to 325/350 127-1023E

0.18 10 0.18 -60 to 325/350 121-1012E

0.40 -60 to 325/350 121-1013E

20 0.18 -60 to 325/350 121-1022E

40 0.40 -60 to 325/350 121-1043E

0.25 30 0.25 -60 to 325/350 122-1032E

1.00 -60 to 325/350 122-1033E

0.32 30 1.00 -60 to 325/350 123-1033E

60 5.00 -60 to 280/300 123-1065E

0.53 10 2.65 -60 to 260/280 125-10HBE

15 0.15 -60 to 340/360 125-1011E

1.50 -60 to 300/320 125-1012E

30 3.00 -60 to 260/280 125-1034E

5.00 -60 to 260/280 125-1035E

60 1.50 -60 to 300/320 125-1062E

60 5.00 -60 to 260/280 125-1065E

DB-1ms, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 340/360 121-0122E

0.20 25 0.33 -60 to 340/350 128-0122E

0.25 15 0.25 -60 to 340/360 122-0112E

30 0.25 -60 to 340/360 122-0132E

5 in. Cage Columns

Page 81: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

298

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

DB-5, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 10 0.10 -60 to 325/350 127-5012E

20 0.10 -60 to 325/350 127-5022E

0.18 10 0.18 -60 to 325/350 121-5012E

20 0.18 -60 to 325/350 121-5022E

0.40 -60 to 325/350 121-5023E

0.25 30 0.25 -60 to 325/350 122-5032E

1.00 -60 to 325/350 122-5033E

0.32 15 0.25 -60 to 325/350 123-5012E

1.00 -60 to 325/350 123-5013E

30 0.25 -60 to 325/350 123-5032E

1.00 -60 to 325/350 123-5033E

60 1.00 -60 to 325/350 123-5063E

0.53 15 1.50 -60 to 300/320 125-5012E

30 1.50 -60 to 300/320 125-5032E

60 1.50 -60 to 300/320 125-5062E

30 5.00 -60 to 260/280 125-5035E

60 5.00 -60 to 260/280 125-5065E

DB-5ms, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 121-5522E

0.25 30 0.25 -60 to 325/350 122-5532E

0.50 -60 to 325/350 122-5536E

1.00 -60 to 325/350 122-5533E

60 0.25 -60 to 325/350 122-5562E

0.32 30 0.25 -60 to 325/350 123-5532E

5 in. Cage Columns

Page 82: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

299

GC and GC/MS

www.agilent.com/chem/supplies

DB-17, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.50 40 to 280/300 122-1713E

30 0.15 40 to 280/300 122-1731E

0.25 40 to 280/300 122-1732E

0.32 30 0.25 40 to 280/300 123-1732E

0.50 40 to 280/300 123-1733E

DB-17ms, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 40 to 320/340 121-4722E

DB-23, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 40 to 250/260 122-2332E

60 0.15 40 to 250/260 122-2361E

0.25 40 to 250/260 122-2362E

0.32 30 0.25 40 to 250/260 123-2332E

DB-210, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 45 to 240/260 122-0232E

DB-225, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 0.25 40 to 220/240 123-2232E

DB-225ms, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 40 to 240 122-2932E

5 in. Cage Columns

Page 83: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

300

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

5 in. Cage Columns

DB-624, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 1.00 -20 to 280 121-1324E

0.20 25 1.12 -20 to 260 128-1324E

0.25 30 1.40 -20 to 260 122-1334E

60 1.40 -20 to 260 122-1364E

0.32 30 1.80 -20 to 260 123-1334E

60 1.80 -20 to 260 123-1364E

0.53 30 3.00 -20 to 260 125-1334E

60 3.00 -20 to 260 125-1364E

75 3.00 -20 to 260 125-1374E

DB-1301, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 60 1.00 -20 to 280/300 122-1363E

0.32 60 1.00 -20 to 280/300 123-1363E

DB-1701, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 -20 to 280/300 122-0732E

1.00 -20 to 280/300 122-0733E

60 1.00 -20 to 280/300 122-0763E

0.32 30 0.25 -20 to 280/300 123-0732E

1.00 -20 to 280/300 123-0733E

60 1.00 -20 to 280/300 123-0763E

0.53 15 1.00 -20 to 260/280 125-0712E

30 1.00 -20 to 260/280 125-0732E

60 1.00 -20 to 260/280 125-0762E

DB-35, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 0.50 40 to 300/320 123-1933E

DB-35ms, 5 in. cageID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 50 to 340/360 121-3822E

0.25 30 0.25 50 to 340/360 122-3832E

0.32 30 0.25 50 to 340/360 123-3832E

Page 84: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

301

GC and GC/MS

www.agilent.com/chem/supplies

DB-FFAP, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 40 to 250 122-3232E

60 0.25 40 to 250 122-3262E

0.32 30 0.25 40 to 250 123-3232E

0.53 30 1.00 40 to 250 125-3232E

DB-MTBE, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 30 3.00 35 to 260/280 125-0034E

DB-Petro, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 100 0.50 -60 to 325/350 122-10A6E

DB-VRX, 5 in. cageID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 40 1.00 -10 to 260 121-1544E

0.25 60 1.40 -10 to 260 122-1564E

0.32 60 1.8 -10 to 260 123-1564E

DB-1701P, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 0.25 -20 to 280/300 123-7732E

5 in. Cage Columns

DB-ALC1 and DB-ALC2, 5 in. cagePhase ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-ALC1 0.53 30 3.00 20 to 260/280 125-9134E

DB-ALC2 0.32 30 1.20 20 to 260/280 123-9234E

Page 85: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

DB-XLB, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 30 to 340/360 121-1222E

0.20 12 0.33 30 to 340/360 128-1212E

0.25 60 0.25 30 to 340/360 122-1262E

GS-Alumina, 5 in. cage

ID (mm) Length (m) Temp Limits (°C) Part No.

0.53 30 -60 to 200 115-3532E

302

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

DB-WAX, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 10 0.10 20 to 250/260 127-7012E

20 0.20 20 to 240/250 127-7023E

0.18 20 0.18 20 to 250/260 121-7022E

0.30 20 to 240/250 121-7023E

40 0.18 20 to 250/260 121-7042E

0.25 15 0.25 20 to 250/260 122-7012E

30 0.25 20 to 250/260 122-7032E

0.50 20 to 240/250 122-7033E

60 0.25 20 to 250/260 122-7062E

0.50 20 to 240/250 122-7063E

0.32 30 0.25 20 to 250/260 123-7032E

0.50 20 to 240/250 123-7033E

60 0.50 20 to 240/250 123-7063E

0.53 15 1.00 20 to 230/240 125-7012E

30 1.00 20 to 230/240 125-7032E

60 1.00 20 to 230/240 125-7062E

DB-WAXetr, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 30 to 260/280 122-7332E

0.32 50 1.00 30 to 250/260 123-7354E

0.53 30 1.00 30 to 240/260 125-7332E

2.00 50 to 230/250 125-7334E

5 in. Cage Columns

Page 86: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

303

GC and GC/MS

www.agilent.com/chem/supplies

GS-Q, 5 in. cage

ID (mm) Length (m) Temp Limits (°C) Part No.

0.32 30 -60 to 250 113-3432E

0.53 30 -60 to 250 115-3432E

GS-OxyPLOT, 5 in. cageID (mm) Length (m) Temp Limits (°C) Part No.

0.53 10 350 115-4912E

5-in Cage Columns

HP-1, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091Z-577E

0.20 25 0.33 -60 to 325/350 19091Z-102E

0.25 30 0.25 -60 to 325/350 19091Z-433E

1.00 -60 to 325/350 19091Z-233E

60 1.00 -60 to 325/350 19091Z-236E

100 0.50 -60 to 325/350 19091Z-530E

0.32 15 0.25 -60 to 325/350 19091Z-411E

25 0.17 -60 to 325/350 19091Z-012E

0.52 -60 to 325/350 19091Z-112E

30 0.10 -60 to 325/350 19091Z-313E

0.25 -60 to 325/350 19091Z-413E

1.00 -60 to 325/350 19091Z-213E

3.00 -60 to 325/350 19091Z-513E

5.00 -60 to 300/320 19091Z-713E

50 0.52 -60 to 325/350 19091Z-115E

60 1.00 -60 to 325/350 19091Z-216E

0.53 5 2.65 -60 to 260/280 19095S-100E

7.5 5.00 -60 to 260/280 19095Z-627E

10 0.88 -60 to 300/320 19095Z-021E

2.65 -60 to 260/280 19095Z-121E

15 0.15 -60 to 320/400 19095Z-221E

3.00 -60 to 260/280 19095Z-421E

30 0.88 -60 to 300/320 19095Z-023E

2.65 -60 to 260/280 19095Z-123E

1.50 -60 to 300/320 19095Z-323E

3.00 -60 to 260/280 19095Z-423E

5.00 -60 to 260/280 19095Z-623E

5 in. Cage Columns

Page 87: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

304

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

HP-1ms, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091S-677E

0.20 25 0.33 -60 to 325/350 19091S-602E

0.25 15 0.25 -60 to 325/350 19091S-931E

30 0.25 -60 to 325/350 19091S-933E

1.00 -60 to 325/350 19091S-733E

60 0.25 -60 to 325/350 19091S-936E

0.32 30 0.25 -60 to 325/350 19091S-913E

HP-5, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091J-577E

0.20 25 0.33 -60 to 325/350 19091J-102E

50 0.33 -60 to 325/350 19091J-105E

0.25 15 0.25 -60 to 325/350 19091J-431E

30 0.25 -60 to 325/350 19091J-433E

60 0.25 -60 to 325/350 19091J-436E

1.00 -60 to 325/350 19091J-236E

0.32 25 0.17 -60 to 325/350 19091J-012E

0.52 -60 to 325/350 19091J-112E

30 0.50 -60 to 325/350 19091J-113E

0.25 -60 to 325/350 19091J-413E

1.00 -60 to 325/350 19091J-213E

50 1.05 -60 to 325/350 19091J-215E

60 1.00 -60 to 325/350 19091J-216E

0.53 10 2.65 -60 to 260/280 19095J-121E

30 0.88 -60 to 300/320 19095J-023E

2.65 -60 to 260/280 19095J-123E

1.50 -60 to 300/320 19095J-323E

5.00 -60 to 260/280 19095J-623E

HP-5ms, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.33 -60 to 325/350 19091S-102E

0.25 30 0.25 -60 to 350/325 19091S-433E

1.00 -60 to 325/350 19091S-233E

60 0.25 -60 to 325/350 19091S-436E

0.32 25 0.52 -60 to 325/350 19091S-112E

30 0.25 -60 to 325/350 19091S-413E

5 in. Cage Columns

Page 88: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

305

GC and GC/MS

www.agilent.com/chem/supplies

HP-20M, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 25 0.30 60 to 220 19091W-012E

50 0.30 60 to 220 19091W-015E

HP-35, 5 in. cageID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.25 40 to 300/320 19091G-131E

5 in. Cage Columns

HP-50+, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 0.25 40 to 280/300 19091L-413E

0.50 40 to 280/300 19091L-113E

0.53 30 0.50 40 to 260/280 19095L-523E

1.00 40 to 260/280 19095L-023E

HP-88, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 100 0.20 0 to 250/260 112-88A7E

30 0.20 0 to 250/260 112-8837E

60 0.20 0 to 250/260 112-8867E

HP-101, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 12 0.25 -60 to 280 19091-60010E

25 0.20 -60 to 280 19091Y-102E

HP-Blood Alcohol, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 7.5 20.00 -60 to 270/290 19091S-510E

HP-Fast Residual Solvent, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 30 1.00 -20 to 260 19095V-420E

Page 89: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

306

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

HP-INNOWax, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 40 to 260/270 19091N-577E

0.20 50 0.20 40 to 260/270 19091N-105E

0.40 40 to 260/270 19091N-205E

0.25 15 0.25 40 to 260/270 19091N-131E

30 0.25 40 to 260/270 19091N-133E

60 0.25 40 to 260/270 19091N-136E

30 0.50 40 to 260/270 19091N-233E

0.32 30 0.25 40 to 260/270 19091N-113E

0.50 40 to 260/270 19091N-213E

60 0.50 40 to 260/270 19091N-216E

0.53 15 1.00 40 to 240/250 19095N-121E

30 1.00 40 to 240/250 19095N-123E

HP-Chiral b, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 0.25 30 to 240/250 19091G-B213E

HP-PLOT Al2O3 "KCl", 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 5.00 -60 to 200 19091P-K33E

0.32 50 8.00 -60 to 200 19091P-K15E

HP-PLOT Al2O3 "M", 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 50 8.00 -60 to 200 19091P-M15E

5 in. Cage Columns

HP-FFAP, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.30 60 to 240/250 19091F-102E

50 0.30 60 to 240/250 19091F-105E

0.25 30 0.25 60 to 240/250 19091F-433E

0.32 25 0.50 60 to 240/250 19091F-112E

50 0.50 60 to 240/250 19091F-115E

0.53 15 1.00 60 to 240 19095F-120E

30 1.00 60 to 240 19095F-123E

Page 90: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

307

GC and GC/MS

www.agilent.com/chem/supplies

5 in. Cage Columns

HP-PLOT Molesieve, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 12.00 -60 to 300 19091P-MS4E

0.53 30 25.00 -60 to 300 19095P-MS6E

30 50.00 -60 to 300 19095P-MS0E

HP-PLOT Q, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 20.00 -60 to 270/290 19091P-QO4E

0.53 15 40.00 -60 to 270/290 19095P-QO3E

30 40.00 -60 to 270/290 19095P-QO4E

HP-PLOT U, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 0.10 -60 to 190 19091P-UO4E

0.53 30 0.20 -60 to 190 19095P-UO4E

HP-PONA, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 50 0.50 -60 to 325/350 19091S-001E

Ultra 1, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.33 -60 to 325/350 19091A-102E

Ultra 2, 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.33 -60 to 325/350 19091B-102E

50 0.33 -60 to 325/350 19091B-105E

0.32 25 0.17 -60 to 325/350 19091B-012E

50 0.52 -60 to 325/350 19091B-115E

HP-PLOT Al2O3 "S", 5 in. cage

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 50 8.00 -60 to 200 19091P-S15E

0.53 50 15.00 -60 to 200 19095P-S25E

Page 91: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

308

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

LTM Column Modules

Agilent J&W LTM Column Modules

• Suitable for majority of Agilent J&W Capillary GC columns (30 m maximum length)

• Rapid temperature programming rates of up to 1800°C/min

• Fast cooling times – less than one minute for some configurations

• Excellent retention time repeatability, comparable to conventional GC

• Ability to run up to four column modules simultaneously, using different temperature programs

• Works with 7890/6890 GC injectors and detectors for little change to your existing methods

• Compatible with Agilent Capillary Flow Technology, for multi-dimensional GC

LTM column modules combine a fused silica capillary column with heating and temperaturesensing components wound around it. The design heats and cools the column very efficientlyfor significantly shorter analytical cycle times compared to conventional air-bath GC oventechniques, while simultaneously using less power.

All LTM column modules come standard with the following:

• Two 1 meter guard columns (deactivated fused silica tubing) of the same internal diameteras the analytical column, one each for inlet and detector

• Package of five non-reusable ferrules that are appropriate for the dimensions of the guardcolumns and analytical columns

NEW!

LTM column modules are available in two column assembly sizes: 5 inch diameter (standard)and 3 inch diameter (small). The standard format provides faster cooling speeds than thesmall format. Since the chromatography quality is basically equivalent for the two modulesizes, Agilent recommends the 5 inch (standard) configuration.

When utilizing the 3 inch (small) configuration, up to four column modules can be installed per Agilent LTM system, enabling multidimensional GC applications. With the 5 inch (standard)configuration, two column modules can be installed per Agilent LTM system. Module sizes canbe mixed so that one 5-inch column module can be used with either one or two 3 inchcolumn modules.

The majority of Agilent J&W Capillary GC columns can be used for LTM column modules,including Wall Coated Open Tubular (WCOT) columns and Porous Layer Open Tubular (PLOT)columns. Any capillary GC column with column length up to 30 meters can be put into the 5 inch format. The 3 inch format is limited to capillary GC columns with column innerdiameters (ID) of 0.32 mm or smaller. The 3 inch format is not recommended for PLOTcolumns or any capillary column that is known to be especially fragile.

Page 92: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

309

GC and GC/MS

www.agilent.com/chem/supplies

LTM Column Modules

CAM LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.25 60 to 220/240 112-2112LTM

30 0.25 60 to 220/240 112-2132LTM

0.50 60 to 220/240 112-2133LTM

0.32 30 0.25 60 to 220/240 113-2132LTM

0.50 60 to 220/240 113-2133LTM

0.53 30 1.00 60 to 200/220 115-2132LTM

Carbowax 20M LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 60 to 220/240 112-2032LTM

0.32 30 0.25 60 to 220/240 113-2032LTM

Cyclodex-B LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 10 to 230/250 112-2532LTM

0.32 30 0.25 10 to 230/250 113-2532LTM

Agilent LTM System

The Agilent LTM (Low Thermal Mass) system was created to greatly enhance the columntemperature programming capabilities of the Agilent 7890A and 6890 series gaschromatographs. The LTM system consists of a replacement door with built-in electronicsand slots for inserting one to four LTM GC column modules. The proprietary designallows each module to be independently temperature programmed. The LTM columnmodules extend outside the GC oven door to allow fast heating and cooling in theambient air while the GC oven operates isothermally. Deactivated fused silica transferline connections are made inside the oven to existing injectors, detectors, valves andother modules as desired, regardless of their placement around the oven. By interfacingthrough the existing oven, the operator retains the original chromatograph’s automatedsampling, sample injection, detection options, and software.

For more information, visit www.agilent.com/chem/LTM.

Page 93: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

310

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

LTM Column Modules

CycloSil-B LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 10 to 250 112-6632LTM

0.32 30 0.25 10 to 250 113-6632LTM

DB-1 LTM Column ModulesID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.05 10 0.05 -60 to 325/350 126-1012LTM

0.20 -60 to 325/350 126-1013LTM

0.10 5 0.12 -60 to 325/350 127-100ALTM

10 0.10 -60 to 325/350 127-1012LTM

0.40 -60 to 325/350 127-1013LTM

20 0.10 -60 to 325/350 127-1022LTM

0.40 -60 to 325/350 127-1023LTM

0.15 10 1.20 -60 to 280/300 12A-1015LTM

0.18 10 0.18 -60 to 325/350 121-1012LTM

0.20 -60 to 325/350 121-101ALTM

0.40 -60 to 325/350 121-1013LTM

20 0.18 -60 to 325/350 121-1022LTM

0.40 -60 to 325/350 121-1023LTM

Page 94: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

311

GC and GC/MS

www.agilent.com/chem/supplies

0.20 12 0.33 -60 to 325/350 128-1012LTM

25 0.33 -60 to 325/350 128-1022LTM

30 0.80 -60 to 325/350 128-1034LTM

0.25 15 0.10 -60 to 325/350 122-1011LTM

0.25 -60 to 325/350 122-1012LTM

1.00 -60 to 325/350 122-1013LTM

25 0.25 -60 to 325/350 122-1022LTM

30 0.10 -60 to 325/350 122-1031LTM

0.25 -60 to 325/350 122-1032LTM

0.50 -60 to 325/350 122-103ELTM

1.00 -60 to 325/350 122-1033LTM

0.32 10 0.50 -60 to 325/350 123-100ELTM

15 0.10 -60 to 325/350 123-1011LTM

0.25 -60 to 325/350 123-1012LTM

1.00 -60 to 325/350 123-1013LTM

3.00 -60 to 280/300 123-1014LTM

5.00 -60 to 280/300 123-1015LTM

25 0.12 -60 to 325/350 123-1027LTM

0.25 -60 to 325/350 123-1022LTM

0.52 -60 to 325/350 123-1026LTM

1.05 -60 to 325/350 123-102FLTM

30 0.10 -60 to 325/350 123-1031LTM

0.25 -60 to 325/350 123-1032LTM

0.50 -60 to 325/350 123-103ELTM

1.00 -60 to 325/350 123-1033LTM

1.50 -60 to 300/320 123-103BLTM

3.00 -60 to 280/300 123-1034LTM

5.00 -60 to 280/300 123-1035LTM

LTM Column Modules

0.45 30 1.27 -60 to 300/320 124-1032LTM

2.55 -60 to 260/280 124-1034LTM

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-1 LTM Column Modules

Agilent LTM column module technology is compatible with metalcapillary columns, but LTM modules are generally not recommended for fast GC applications because of their poor cooling performancecompared to fused silica capillaries.

Tips & Tools

Page 95: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

312

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

LTM Column Modules

5.00 -60 to 260/280 125-10H5LTM

15 0.15 -60 to 340/360 125-1011LTM

0.25 -60 to 320/340 125-101KLTM

0.50 -60 to 300/320 125-1017LTM

1.00 -60 to 300/320 125-101JLTM

1.50 -60 to 300/320 125-1012LTM

3.00 -60 to 260/280 125-1014LTM

5.00 -60 to 260/280 125-1015LTM

25 1.00 -60 to 300/320 125-102JLTM

5.00 -60 to 260/280 125-1025LTM

30 0.10 -60 to 340/360 125-1039LTM

0.50 -60 to 300/320 125-1037LTM

1.00 -60 to 300/320 125-103JLTM

1.50 -60 to 300/320 125-1032LTM

2.65 -60 to 260/280 125-103BLTM

3.00 -60 to 260/280 125-1034LTM

5.00 -60 to 260/280 125-1035LTM

0.25 -60 to 320/340 125-103KLTM

DB-1ht LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.10 -60 to 400 122-1111LTM

30 0.10 -60 to 400 122-1131LTM

0.32 15 0.10 -60 to 400 123-1111LTM

30 0.10 -60 to 400 123-1131LTM

0.53 5 0.88 -60 to 300/320 125-100ALTM

2.65 -60 to 260/280 125-100BLTM

5.00 -60 to 260/280 125-1005LTM

7.5 1.50 -60 to 300/320 125-1002LTM

10 2.65 -60 to 260/280 125-10HBLTM

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-1 LTM Column Modules

LTM column modules shouldnever be programmedbeyond the GC columntemperature limitsrecommended by Agilent.For very fast rampingapplications (e.g.600°C/min), limiting themaximum temperatures to 10-20°C below the GCcolumn temperature limitscan increase the lifetime of the column modules.

Tips & Tools

Page 96: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

313

GC and GC/MS

www.agilent.com/chem/supplies

DB-1ms LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 10 0.10 -60 to 340/360 127-0112LTM

0.40 -60 to 340/360 127-0113LTM

20 0.10 -60 to 340/360 127-0122LTM

0.40 -60 to 340/360 127-0123LTM

0.18 20.0 0.18 -60 to 340/360 121-0122LTM

0.20 12 0.33 -60 to 340/350 128-0112LTM

25 0.33 -60 to 340/350 128-0122LTM

0.25 15 0.25 -60 to 340/360 122-0112LTM

30 0.10 -60 to 340/360 122-0131LTM

0.25 -60 to 340/360 122-0132LTM

0.32 15 0.25 -60 to 340/360 123-0112LTM

30 0.10 -60 to 340/360 123-0131LTM

0.25 -60 to 340/360 123-0132LTM

LTM Column Modules

DB-1301 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 10 0.40 -20 to 280/300 121-1313LTM

0.25 30 0.25 -20 to 280/300 122-1332LTM

1.00 -20 to 280/300 122-1333LTM

0.32 30 0.25 -20 to 280/300 123-1332LTM

1.00 -20 to 280/300 123-1333LTM

0.53 15 1.00 -20 to 260/280 125-1312LTM

30 1.00 -20 to 260/280 125-1332LTM

1.50 -20 to 260/280 125-1333LTM

Page 97: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

314

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

LTM Column Modules

DB-17ht LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 5 0.15 40 to 340/365 122-1801LTM

15 0.15 40 to 340/365 122-1811LTM

30 0.15 40 to 340/365 122-1831LTM

0.32 15 0.15 40 to 340/365 123-1811LTM

30 0.15 40 to 340/365 123-1831LTM

DB-17 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.05 10 0.10 40 to 280/300 126-1713LTM

0.10 10 0.10 40 to 280/300 127-1712LTM

0.20 40 to 280/300 127-1713LTM

20 0.10 40 to 280/300 127-1722LTM

0.18 20 0.18 40 to 280/300 121-1722LTM

0.30 40 to 280/300 121-1723LTM

0.25 15 0.15 40 to 280/300 122-1711LTM

0.25 40 to 280/300 122-1712LTM

0.50 40 to 280/300 122-1713LTM

30 0.15 40 to 280/300 122-1731LTM

0.25 40 to 280/300 122-1732LTM

0.50 40 to 280/300 122-1733LTM

0.32 15 0.15 40 to 280/300 123-1711LTM

0.25 40 to 280/300 123-1712LTM

0.50 40 to 280/300 123-1713LTM

30 0.15 40 to 280/300 123-1731LTM

0.25 40 to 280/300 123-1732LTM

0.50 40 to 280/300 123-1733LTM

0.53 5 2.00 40 to 260/280 125-1704LTM

15 0.25 40 to 260/280 125-1711LTM

0.50 40 to 260/280 125-1717LTM

1.00 40 to 260/280 125-1712LTM

1.50 40 to 260/280 125-1713LTM

30 0.25 40 to 260/280 125-1731LTM

0.50 40 to 260/280 125-1737LTM

1.00 40 to 260/280 125-1732LTM

1.50 40 to 260/280 125-1733LTM

Page 98: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

315

GC and GC/MS

www.agilent.com/chem/supplies

DB-17ms LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 40 to 320/340 121-4722LTM

0.25 15 0.15 40 to 320/340 122-4711LTM

15 0.25 40 to 320/340 122-4712LTM

30 0.15 40 to 320/340 122-4731LTM

30 0.25 40 to 320/340 122-4732LTM

0.32 15 0.25 40 to 320/340 123-4712LTM

30 0.25 40 to 320/340 123-4732LTM

DB-1701 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 20 0.10 -20 to 280/300 127-0722LTM

0.40 -20 to 280/300 127-0723LTM

0.18 10 0.40 -20 to 280/300 121-0713LTM

20 0.18 -20 to 280/300 121-0722LTM

0.25 15 0.25 -20 to 280/300 122-0712LTM

1.00 -20 to 280/300 122-0713LTM

30 0.15 -20 to 280/300 122-0731LTM

0.25 -20 to 280/300 122-0732LTM

1.00 -20 to 280/300 122-0733LTM

0.32 15 0.25 -20 to 280/300 123-0712LTM

1.00 -20 to 280/300 123-0713LTM

30 0.15 -20 to 280/300 123-0731LTM

0.25 -20 to 280/300 123-0732LTM

1.00 -20 to 280/300 123-0733LTM

0.53 15 1.00 -20 to 260/280 125-0712LTM

30 0.25 -20 to 260/280 125-0731LTM

0.50 -20 to 260/280 125-0737LTM

1.00 -20 to 260/280 125-0732LTM

1.50 -20 to 260/280 125-0733LTM

LTM Column Modules

DB-1701P LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 -20 to 280/300 122-7732LTM

0.32 25 0.25 -20 to 280/300 123-7722LTM

30 0.25 -20 to 280/300 123-7732LTM

0.53 30 1.00 -20 to 260/280 125-7732LTM

Page 99: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

316

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

DB-225ms LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.25 40 to 240 122-2912LTM

30 0.25 40 to 240 122-2932LTM

0.32 30 0.25 40 to 240 123-2932LTM

LTM Column Modules

DB-225 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 20 0.10 40 to 220/240 127-2222LTM

0.18 20 0.20 40 to 220/240 121-2223LTM

0.25 15 0.25 40 to 220/240 122-2212LTM

30 0.15 40 to 220/240 122-2231LTM

0.25 40 to 220/240 122-2232LTM

0.32 30 0.25 40 to 220/240 123-2232LTM

0.53 15 1.00 40 to 200/220 125-2212LTM

30 1.00 40 to 200/220 125-2232LTM

0.50 40 to 200/220 125-2237LTM

DB-200 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 30 to 300/320 122-2032LTM

0.50 30 to 300/320 122-2033LTM

0.32 30 0.25 30 to 300/320 123-2032LTM

0.50 30 to 300/320 123-2033LTM

0.53 30 1.00 30 to 280/300 125-2032LTM

DB-210 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.25 45 to 240/260 122-0212LTM

30 0.25 45 to 240/260 122-0232LTM

0.50 45 to 240/260 122-0233LTM

0.32 15 0.50 45 to 240/260 123-0213LTM

30 0.25 45 to 240/260 123-0232LTM

0.50 45 to 240/260 123-0233LTM

0.53 15 1.00 45 to 220/240 125-0212LTM

30 1.00 45 to 220/240 125-0232LTM

Page 100: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

317

GC and GC/MS

www.agilent.com/chem/supplies

DB-23 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.20 40 to 250/260 121-2323LTM

0.25 15 0.25 40 to 250/260 122-2312LTM

30 0.15 40 to 250/260 122-2331LTM

0.25 40 to 250/260 122-2332LTM

0.32 30 0.25 40 to 250/260 123-2332LTM

0.53 15 0.50 40 to 230/240 125-2312LTM

30 0.50 40 to 230/240 125-2332LTM

DB-2887 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 10 3.00 -60 to 350 125-2814LTM

DB-35 LTM Column ModulesID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 40 to 300/320 122-1932LTM

0.32 30 0.25 40 to 300/320 123-1932LTM

0.50 40 to 300/320 123-1933LTM

0.53 15 1.00 40 to 280/300 125-1912LTM

30 1.00 40 to 280/300 125-1932LTM

0.50 40 to 280/300 125-1937LTM

DB-35ms LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20.0 0.18 50 to 340/360 121-3822LTM

0.20 15 0.33 50 to 340/360 128-3812LTM

25 0.33 50 to 340/360 128-3822LTM

0.25 15 0.25 50 to 340/360 122-3812LTM

30 0.15 50 to 340/360 122-3831LTM

0.25 50 to 340/360 122-3832LTM

0.32 15 0.25 50 to 340/360 123-3812LTM

30 0.25 50 to 340/360 123-3832LTM

0.53 30 0.50 50 to 320/340 125-3837LTM

1.00 50 to 320/340 125-3832LTM

LTM Column Modules

Page 101: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

318

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

LTM Column Modules

DB-5 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 10 0.10 -60 to 325/350 127-5012LTM

0.17 -60 to 325/350 127-501ELTM

0.34 -60 to 325/350 127-501NLTM

0.40 -60 to 325/350 127-5013LTM

20 0.10 -60 to 325/350 127-5022LTM

20 0.40 -60 to 325/350 127-5023LTM

0.15 10.0 1.20 -60 to 300/320 12A-5015LTM

0.18 10 0.18 -60 to 325/350 121-5012LTM

0.40 -60 to 325/350 121-5013LTM

20 0.18 -60 to 325/350 121-5022LTM

0.40 -60 to 325/350 121-5023LTM

0.20 12 0.33 -60 to 325/350 128-5012LTM

15 0.20 -60 to 325/350 128-50H7LTM

25 0.33 -60 to 325/350 128-5022LTM

0.25 15 0.10 -60 to 325/350 122-5011LTM

0.25 -60 to 325/350 122-5012LTM

0.50 -60 to 325/350 122-501ELTM

1.00 -60 to 325/350 122-5013LTM

25 0.25 -60 to 325/350 122-5022LTM

30 0.10 -60 to 325/350 122-5031LTM

0.25 -60 to 325/350 122-5032LTM

0.50 -60 to 325/350 122-503ELTM

1.00 -60 to 325/350 122-5033LTM

0.32 10 0.50 -60 to 325/350 123-500ELTM

15 0.10 -60 to 325/350 123-5011LTM

0.25 -60 to 325/350 123-5012LTM

1.00 -60 to 325/350 123-5013LTM

25 0.17 -60 to 325/350 123-502DLTM

0.25 -60 to 325/350 123-5022LTM

0.52 -60 to 325/350 123-5026LTM

1.05 -60 to 325/350 123-502FLTM

30 0.10 -60 to 325/350 123-5031LTM

0.25 -60 to 325/350 123-5032LTM

0.50 -60 to 325/350 123-503ELTM

1.00 -60 to 325/350 123-5033LTM

1.50 -60 to 325/350 123-503BLTM

Page 102: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

319

GC and GC/MS

www.agilent.com/chem/supplies

0.45 15 1.27 -60 to 300/320 124-5012LTM

30 0.42 -60 to 300/320 124-5037LTM

1.27 -60 to 300/320 124-5032LTM

0.53 10 2.65 -60 to 260/280 125-50HBLTM

15 0.25 -60 to 300/320 125-501KLTM

0.50 -60 to 300/320 125-5017LTM

1.00 -60 to 300/320 125-501JLTM

1.50 -60 to 300/320 125-5012LTM

25 5.00 -60 to 260/280 125-5025LTM

30 0.25 -60 to 300/320 125-503KLTM

0.50 -60 to 300/320 125-5037LTM

0.88 -60 to 300/320 125-503DLTM

1.00 -60 to 300/320 125-503JLTM

1.50 -60 to 300/320 125-5032LTM

2.65 -60 to 260/280 125-503BLTM

3.00 -60 to 260/280 125-5034LTM

5.00 -60 to 260/280 125-5035LTM

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-5 LTM Column Modules

DB-5ht LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.10 -60 to 400 122-5711LTM

30 0.10 -60 to 400 122-5731LTM

0.32 10 0.10 -60 to 400 123-5701LTM

15 0.10 -60 to 400 123-5711LTM

30 0.10 -60 to 400 123-5731LTM

LTM Column Modules

Page 103: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

320

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

DB-5ms LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 121-5522LTM

0.36 -60 to 325/350 121-5523LTM

0.20 12 0.33 -60 to 325/350 128-5512LTM

25 0.33 -60 to 325/350 128-5522LTM

0.25 15 0.10 -60 to 325/350 122-5511LTM

0.25 -60 to 325/350 122-5512LTM

0.50 -60 to 325/350 122-5516LTM

1.00 -60 to 325/350 122-5513LTM

25 0.25 -60 to 325/350 122-5522LTM

0.40 -60 to 325/350 122-552ALTM

30 0.10 -60 to 325/350 122-5531LTM

0.25 -60 to 325/350 122-5532LTM

0.50 -60 to 325/350 122-5536LTM

1.00 -60 to 325/350 122-5533LTM

0.32 15 0.10 -60 to 325/350 123-5511LTM

0.25 -60 to 325/350 123-5512LTM

1.00 -60 to 325/350 123-5513LTM

25 0.52 -60 to 325/350 123-5526LTM

30 0.10 -60 to 325/350 123-5531LTM

0.25 -60 to 325/350 123-5532LTM

0.50 -60 to 325/350 123-5536LTM

1.00 -60 to 325/350 123-5533LTM

0.53 15 1.50 -60 to 300/320 125-5512LTM

30 0.50 -60 to 300/320 125-5537LTM

1.00 -60 to 300/320 125-553JLTM

1.50 -60 to 300/320 125-5532LTM

LTM Column Modules

DB-5ms Ultra Inert LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 121-5522UILTM

0.36 -60 to 325/350 121-5523UILTM

0.25 15 0.25 -60 to 325/350 122-5512UILTM

1.00 -60 to 325/350 122-5513UILTM

25 0.25 -60 to 325/350 122-5522UILTM

30 0.25 -60 to 325/350 122-5532UILTM

0.50 -60 to 325/350 122-5536UILTM

1.00 -60 to 325/350 122-5533UILTM

0.32 30 0.25 -60 to 325/350 123-5532UILTM

0.50 -60 to 325/350 123-5536UILTM

1.00 -60 to 325/350 123-5533UILTM

Page 104: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

321

GC and GC/MS

www.agilent.com/chem/supplies

LTM Column Modules

DB-5.625 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 121-5621LTM

0.36 -60 to 325/350 121-5622LTM

0.25 30 0.25 -60 to 325/350 122-5631LTM

0.50 -60 to 325/350 122-5632LTM

1.00 -60 to 325/350 122-5633LTM

0.32 30 0.25 -60 to 325/350 123-5631LTM

0.50 -60 to 325/350 123-5632LTM

DB-608 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 40 to 280/300 121-6822LTM

0.25 30 0.25 40 to 280/300 122-6832LTM

0.32 30 0.50 40 to 280/300 123-1730LTM

0.45 30 0.70 40 to 260/280 124-1730LTM

0.53 15 0.83 40 to 260/280 125-1710LTM

30 0.50 40 to 260/280 125-6837LTM

0.83 40 to 260/280 125-1730LTM

DB-624 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 1.00 -20 to 260 121-1324LTM

0.20 25 1.12 -20 to 260 128-1324LTM

0.25 30 1.40 -20 to 260 122-1334LTM

0.32 30 1.80 -20 to 260 123-1334LTM

0.45 30 2.55 -20 to 260 124-1334LTM

0.53 30 3.00 -20 to 260 125-1334LTM

DB-ALC1 and DB-ALC2 LTM Column Modules

Phase ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

DB-ALC1 0.32 30 1.80 20 to 260/280 123-9134LTM

0.53 30 3.00 20 to 260/280 125-9134LTM

DB-ALC2 0.32 30 1.20 20 to 260/280 123-9234LTM

0.53 30 2.00 20 to 260/280 125-9234LTM

Page 105: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

322

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

DB-FFAP LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.10 10 0.10 40 to 250 127-3212LTM

15 0.10 40 to 250 127-32H2LTM

0.25 15 0.25 40 to 250 122-3212LTM

30 0.25 40 to 250 122-3232LTM

0.50 40 to 250 122-3233LTM

0.32 15 0.25 40 to 250 123-3212LTM

25 0.50 40 to 250 123-3223LTM

30 0.25 40 to 250 123-3232LTM

0.50 40 to 250 123-3233LTM

1.00 40 to 250 123-3234LTM

0.45 30 0.85 40 to 250 124-3232LTM

0.53 10 1.00 40 to 250 125-32H2LTM

15 0.50 40 to 250 125-3217LTM

1.00 40 to 250 125-3212LTM

30 0.25 40 to 250 125-3231LTM

0.50 40 to 250 125-3237LTM

1.00 40 to 250 125-3232LTM

1.50 40 to 250 125-3233LTM

DB-MTBE LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.45 30 2.55 35 to 260/280 124-0034LTM

0.53 30 3.00 35 to 260/280 125-0034LTM

DB-TPH LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 0.25 -10 to 320 123-1632LTM

DB-VRX LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 1.00 -10 to 260 121-1524LTM

40 1.00 -10 to 260 121-1544LTM

0.25 30 1.40 -10 to 260 122-1534LTM

0.32 30 1.80 -10 to 260 123-1534LTM

0.45 30 2.55 -10 to 260 124-1534LTM

LTM Column Modules

Page 106: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

323

GC and GC/MS

www.agilent.com/chem/supplies

LTM Column Modules

DB-WAX LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.05 10 0.05 20 to 250/260 126-7012LTM

0.10 20 to 240/250 126-7013LTM

0.10 10 0.10 20 to 250/260 127-7012LTM

0.20 20 to 240/250 127-7013LTM

20 0.10 20 to 250/260 127-7022LTM

0.20 20 to 240/250 127-7023LTM

0.18 10 0.18 20 to 250/260 121-7012LTM

20 0.18 20 to 250/260 121-7022LTM

0.30 20 to 240/250 121-7023LTM

0.20 25 0.20 20 to 250/260 128-7022LTM

30 0.20 20 to 250/260 128-7032LTM

0.25 15 0.25 20 to 250/260 122-7012LTM

0.50 20 to 240/250 122-7013LTM

30 0.15 20 to 250/260 122-7031LTM

0.25 20 to 250/260 122-7032LTM

0.50 20 to 240/250 122-7033LTM

0.32 15 0.25 20 to 250/260 123-7012LTM

0.50 20 to 240/250 123-7013LTM

30 0.15 20 to 250/260 123-7031LTM

0.25 20 to 250/260 123-7032LTM

0.50 20 to 240/250 123-7033LTM

0.45 30 0.85 20 to 230/240 124-7032LTM

0.53 15 0.50 20 to 230/240 125-7017LTM

1.00 20 to 230/240 125-7012LTM

30 0.25 20 to 230/240 125-7031LTM

0.50 20 to 230/240 125-7037LTM

1.00 20 to 230/240 125-7032LTM

DB-WAXetr LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.40 30 to 250/260 128-7323LTM

0.25 30 0.25 30 to 260/280 122-7332LTM

0.50 30 to 250/260 122-7333LTM

0.32 15 0.25 30 to 260/280 123-7312LTM

1.00 30 to 250/260 123-7314LTM

30 0.25 30 to 260/280 123-7332LTM

0.50 30 to 250/260 123-7333LTM

1.00 30 to 250/260 123-7334LTM

0.53 15 1.00 30 to 240/260 125-7312LTM

2.00 50 to 230/250 125-7314LTM

30 1.00 30 to 240/260 125-7332LTM

1.50 30 to 230/240 125-7333LTM

2.00 50 to 230/250 125-7334LTM

Page 107: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

324

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

DB-XLB LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 30 to 340/360 121-1222LTM

30 0.18 30 to 340/360 121-1232LTM

0.20 12 0.33 30 to 340/360 128-1212LTM

25 0.33 30 to 340/360 128-1222LTM

0.25 15 0.10 30 to 340/360 122-1211LTM

0.25 30 to 340/360 122-1212LTM

30 0.10 30 to 340/360 122-1231LTM

0.25 30 to 340/360 122-1232LTM

0.50 30 to 340/360 122-1236LTM

1.00 30 to 340/360 122-1233LTM

0.32 30 0.25 30 to 340/360 123-1232LTM

0.50 30 to 330/360 123-1236LTM

0.53 15 1.50 30 to 320/340 125-1212LTM

30 1.50 30 to 320/340 125-1232LTM

DX-1 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 1.00 50 to 250/270 123-6133LTM

DX-4 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 50 to 250/270 122-6432LTM

0.32 15 0.25 50 to 250/270 123-6412LTM

30 0.25 50 to 250/270 123-6432LTM

GS-Alumina LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 30 0.00 -60 to 200 115-3532LTM

GS-Alumina KCl LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 30 0.00 -60 to 200 115-3332LTM

GS-CarbonPLOT LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 15 1.50 0 to 360 113-3112LTM

30 1.50 0 to 360 113-3132LTM

3.00 0 to 360 113-3133LTM

0.53 15 3.00 0 to 360 115-3113LTM

30 3.00 0 to 360 115-3133LTM

LTM Column Modules

Page 108: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

325

GC and GC/MS

www.agilent.com/chem/supplies

GS-Q LTM Column Modules

ID (mm) Length (m) Temp Limits (°C) Part No.

0.32 30 -60 to 250 113-3432LTM

0.53 10 -60 to 250 115-34H2LTM

15 -60 to 250 115-3412LTM

25 -60 to 250 115-3422LTM

30 -60 to 250 115-3432LTM

LTM Column Modules

HP-1 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091Z-577LTM

0.20 17 0.11 -60 to 325/350 19091Z-008LTM

25 0.11 -60 to 325/350 19091Z-002LTM

0.33 -60 to 325/350 19091Z-102LTM

0.50 -60 to 325/350 19091Z-202LTM

0.25 15 0.10 -60 to 325/350 19091Z-331LTM

0.25 -60 to 325/350 19091Z-431LTM

1.00 -60 to 325/350 19091Z-231LTM

30 0.10 -60 to 325/350 19091Z-333LTM

0.25 -60 to 325/350 19091Z-433LTM

1.00 -60 to 325/350 19091Z-233LTM

0.32 15 0.25 -60 to 325/350 19091Z-411LTM

1.00 -60 to 325/350 19091Z-211LTM

25 0.17 -60 to 325/350 19091Z-012LTM

0.52 -60 to 325/350 19091Z-112LTM

1.05 -60 to 325/350 19091Z-212LTM

30 0.10 -60 to 325/350 19091Z-313LTM

0.25 -60 to 325/350 19091Z-413LTM

1.00 -60 to 325/350 19091Z-213LTM

3.00 -60 to 260/280 19091Z-513LTM

4.00 -60 to 260/280 19091Z-613LTM

5.00 -60 to 260/280 19091Z-713LTM

0.53 5 0.88 -60 to 320/400 19095Z-020LTM

2.65 -60 to 260/280 19095S-100LTM

7.5 5.00 -60 to 260/280 19095Z-627LTM

10 0.88 -60 to 300/320 19095Z-021LTM

2.65 -60 to 260/280 19095Z-121LTM

15 1.50 -60 to 300/320 19095Z-321LTM

3.00 -60 to 260/280 19095Z-421LTM

5.00 -60 to 260/280 19095Z-621LTM

30.0 0.88 -60 to 300/320 19095Z-023LTM

1.50 -60 to 300/320 19095Z-323LTM

2.65 -60 to 260/280 19095Z-123LTM

3.00 -60 to 260/280 19095Z-423LTM

5.00 -60 to 260/280 19095Z-623LTM

Page 109: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

326

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

HP-1ms LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091S-677LTM

0.20 25 0.33 -60 to 325/350 19091S-602LTM

0.25 15 0.25 -60 to 325/350 19091S-931LTM

30 0.10 -60 to 325/350 19091S-833LTM

0.25 -60 to 325/350 19091S-933LTM

0.50 -60 to 325/350 19091S-633LTM

1.00 -60 to 325/350 19091S-733LTM

0.32 15 0.25 -60 to 325/350 19091S-911LTM

25 0.52 -60 to 325/350 19091S-612LTM

30 0.25 -60 to 325/350 19091S-913LTM

1.00 -60 to 325/350 19091S-713LTM

HP-101 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.20 -60 to 280 19091Y-102LTM

0.32 25 0.30 -60 to 280 19091Y-012LTM

HP-17 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 10 2.00 40 to 260/280 19095L-121LTM

HP-20M LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.10 60 to 220 19091W-102LTM

0.32 25 0.30 60 to 220 19091W-012LTM

0.53 10 1.33 60 to 220 19095W-121LTM

30 1.33 60 to 220 19095W-123LTM

HP-35 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 15 0.25 40 to 300/320 19091G-131LTM

30 0.25 40 to 300/320 19091G-133LTM

0.32 30 0.25 40 to 300/320 19091G-113LTM

0.50 40 to 300/320 19091G-213LTM

LTM Column Modules

Page 110: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

327

GC and GC/MS

www.agilent.com/chem/supplies

LTM Column Modules

HP-5 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091J-577LTM

0.20 12 0.33 -60 to 325/350 19091J-101LTM

25 0.11 -60 to 325/350 19091J-002LTM

0.33 -60 to 325/350 19091J-102LTM

0.50 -60 to 325/350 19091J-202LTM

0.25 5 0.10 -60 to 325/350 19091J-330LTM

15 0.25 -60 to 325/350 19091J-431LTM

1.00 -60 to 325/350 19091J-231LTM

30 0.10 -60 to 325/350 19091J-333LTM

0.25 -60 to 325/350 19091J-433LTM

1.00 -60 to 325/350 19091J-233LTM

0.32 15 0.25 -60 to 325/350 19091J-411LTM

25 0.17 -60 to 325/350 19091J-012LTM

0.52 -60 to 325/350 19091J-112LTM

1.05 -60 to 325/350 19091J-212LTM

30 0.10 -60 to 325/350 19091J-313LTM

0.25 -60 to 325/350 19091J-413LTM

0.50 -60 to 325/350 19091J-113LTM

1.00 -60 to 325/350 19091J-213LTM

0.53 10 2.65 -60 to 260/280 19095J-121LTM

15 1.50 -60 to 300/320 19095J-321LTM

5.00 -60 to 260/280 19095J-621LTM

30 0.88 -60 to 300/320 19095J-023LTM

1.50 -60 to 300/320 19095J-323LTM

2.65 -60 to 260/280 19095J-123LTM

5.00 -60 to 260/280 19095J-623LTM

HP-5ms LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091S-577LTM

0.20 12 0.33 -60 to 325/350 19091S-101LTM

25 0.33 -60 to 325/350 19091S-102LTM

0.25 15 0.10 -60 to 325/350 19091S-331LTM

0.25 -60 to 325/350 19091S-431LTM

1.00 -60 to 325/350 19091S-231LTM

30 0.10 -60 to 325/350 19091S-333LTM

0.25 -60 to 325/350 19091S-433LTM

0.50 -60 to 325/350 19091S-133LTM

1.00 -60 to 325/350 19091S-233LTM

0.32 25 0.52 -60 to 325/350 19091S-112LTM

30 0.10 -60 to 325/350 19091S-313LTM

0.25 -60 to 325/350 19091S-413LTM

0.50 -60 to 325/350 19091S-113LTM

1.00 -60 to 325/350 19091S-213LTM

Page 111: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

328

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

HP-5ms Semivolatile LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30.0 0.50 -60 to 325/350 19091S-139LTM

HP-5ms Ultra Inert LTM Column ModulesID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 -60 to 325/350 19091S-577UILTM

0.25 15 0.25 -60 to 325/350 19091S-431UILTM

30 0.25 -60 to 325/350 19091S-433UILTM

0.50 -60 to 325/350 19091S-133UILTM

1.00 -60 to 325/350 19091S-233UILTM

0.32 30 0.25 -60 to 325/350 19091S-413UILTM

1.00 -60 to 325/350 19091S-213UILTM

LTM Column Modules

HP-50+ LTM Column ModulesID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 40 to 280/300 19091L-577LTM

0.20 12 0.31 40 to 280/300 19091L-101LTM

0.25 5 0.15 40 to 280/300 19091L-330LTM

15 0.25 40 to 280/300 19091L-431LTM

30 0.15 40 to 280/300 19091L-333LTM

0.25 40 to 280/300 19091L-433LTM

0.50 40 to 280/300 19091L-133LTM

0.32 15 0.50 40 to 280/300 19091L-111LTM

30 0.25 40 to 280/300 19091L-413LTM

0.50 40 to 280/300 19091L-113LTM

0.53 15 1.00 40 to 260/280 19095L-021LTM

30 0.50 40 to 260/280 19095L-523LTM

1.00 40 to 260/280 19095L-023LTM

Custom Agilent J&W LTM ColumnModule Ordering

If you need an LTM column module that is not listed, simply order partnumber 100-2000LTM and specify stationary phase, length, inner diameter,film thickness and 5 inch or 3 inch configuration.

Page 112: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

329

GC and GC/MS

www.agilent.com/chem/supplies

LTM Column Modules

HP-PLOT Al2O3 "M" LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 30 15.00 -60 to 200 19095P-M23LTM

HP-PLOT Al2O3 "S" LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 5.00 -60 to 200 19091P-S33LTM

0.32 25 8.00 -60 to 200 19091P-S12LTM

0.53 15 15.00 -60 to 200 19095P-S21LTM

30 15.00 -60 to 200 19095P-S23LTM

HP-Blood Alcohol LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 7.5 20.00 -60 to 270/290 19091S-510LTM

HP-88 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.20 50 to 250/260 112-8837LTM

HP-PLOT Al2O3 "KCl" LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 5.00 -60 to 200 19091P-K33LTM

0.53 30 15.00 -60 to 200 19095P-K23LTM

HP-FFAP LTM Column ModulesID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 25 0.33 60 to 240/250 19091F-102LTM

0.25 30 0.25 60 to 240/250 19091F-433LTM

0.32 25 0.50 60 to 240/250 19091F-112LTM

30 0.25 60 to 240/250 19091F-413LTM

0.53 10 1.00 60 to 240 19095F-121LTM

15 1.00 60 to 240 19095F-120LTM

30 1.00 60 to 240 19095F-123LTM

Page 113: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

330

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

HP-PLOT Molesieve LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 15 25.00 -60 to 300 19091P-MS7LTM

30 12.00 -60 to 300 19091P-MS4LTM

25.00 -60 to 300 19091P-MS8LTM

0.53 15 25.00 -60 to 300 19095P-MS5LTM

50.00 -60 to 300 19095P-MS9LTM

30 50.00 -60 to 300 19095P-MS0LTM

25.00 -60 to 300 19095P-MS6LTM

LTM Column Modules

HP-INNOWax LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.18 20 0.18 40 to 260/270 19091N-577LTM

0.20 25 0.20 40 to 260/270 19091N-102LTM

0.40 40 to 260/270 19091N-202LTM

0.25 4 0.25 40 to 260/270 19091N-130LTM

5 0.15 40 to 260/270 19091N-030LTM

15 0.25 40 to 260/270 19091N-131LTM

0.50 40 to 260/270 19091N-231LTM

30 0.15 40 to 260/270 19091N-033LTM

0.25 40 to 260/270 19091N-133LTM

0.50 40 to 260/270 19091N-233LTM

0.32 15 0.25 40 to 260/270 19091N-111LTM

30 0.15 40 to 260/270 19091N-013LTM

0.25 40 to 260/270 19091N-113LTM

0.50 40 to 260/270 19091N-213LTM

0.53 15 1.00 40 to 240/250 19095N-121LTM

30 1.00 40 to 240/250 19095N-123LTM

Page 114: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

331

GC and GC/MS

www.agilent.com/chem/supplies

LTM Column Modules

HP-PLOT Q LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 15 20.00 -60 to 270/290 19091P-QO3LTM

30 20.00 -60 to 270/290 19091P-QO4LTM

0.53 15 40.00 -60 to 270/290 19095P-QO3LTM

30 40.00 -60 to 270/290 19095P-QO4LTM

HP-PLOT U LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 10.00 -60 to 190 19091P-UO4LTM

0.53 15 20.00 -60 to 190 19095P-UO3LTM

30 20.00 -60 to 190 19095P-UO4LTM

Ultra 1 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 12 0.33 -60 to 325/350 19091A-101LTM

17 0.11 -60 to 325/350 19091A-008LTM

0.33 -60 to 325/350 19091A-108LTM

25 0.11 -60 to 325/350 19091A-002LTM

0.33 -60 to 325/350 19091A-102LTM

0.32 25 0.17 -60 to 325/350 19091A-012LTM

0.52 -60 to 325/350 19091A-112LTM

Ultra 2 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 12 0.33 -60 to 325/350 19091B-101LTM

25 0.11 -60 to 325/350 19091B-002LTM

0.33 -60 to 325/350 19091B-102LTM

0.32 25 0.17 -60 to 325/350 19091B-012LTM

0.52 -60 to 325/350 19091B-112LTM

Page 115: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

332

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

HP-VOC LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.20 30 1.12 -60 to 280/290 19091R-303LTM

HP-PAS5 LTM Column ModulesID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 25 0.52 -60 to 325/350 19091S-010LTM

HP-Fast Residual Solvent LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.53 30 1.00 -20 to 260 19095V-420LTM

SE-30 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.32 30 0.25 0 to 325/350 113-3032LTM

SE-54 LTM Column Modules

ID (mm) Length (m) Film (µm) Temp Limits (°C) Part No.

0.25 30 0.25 0 to 325/350 112-5432LTM

0.32 30 0.25 0 to 325/350 113-5432LTM

LTM Column Modules

Custom Agilent J&W LTM Column Module OrderingFor 3 inch (small) diameter LTM modules, place a custom order using partnumber 100-2000LTM. Be sure to provide the details of your desired column,including stationary phase, length, inner diameter (ID), and film thickness, with a specific request for a 3 inch (small) diameter LTM column module.

Page 116: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

333

GC and GC/MS

www.agilent.com/chem/supplies

Fused Silica Tubing

Deactivated TubingDeactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation – the preferred choice for most applications due to its inertness and robustness.

Deactivated Fused Silica

ID (mm) OD (mm) Length (m) Part No.

0.05 0.36 1 160-2655-1

5 160-2655-5

10 160-2655-10

0.10 0.19 1 160-1010-1

5 160-1010-5

10 160-1010-10

0.36 1 160-2635-1

5 160-2635-5

5 19091-60620E

10 160-2635-10

0.15 0.36 1 160-2625-1

5 160-2625-5

10 160-2625-10

0.18 0.34 1 160-2615-1

5 160-2615-5

10 160-2615-10

0.20 0.36 1 160-2205-1

5 160-2205-5

10 160-2205-10

0.25 0.36 1 160-2255-1

5 160-2255-5

10 160-2255-10

30 160-2255-30

0.32 0.43 1 160-2325-1

5 160-2325-5

10 160-2325-10

30 160-2325-30

0.45 0.67 1 160-2455-1

5 160-2455-5

10 160-2455-10

0.53 0.67 1 160-2535-1

5 160-2535-5

10 160-2535-10

30 160-2535-30

Fused Silica Tubing

Page 117: GC, GC/MS and Duraguard Capillary Columns€¦ · polymer chemistry and proprietary deactivation techniques help us increase temperature limits (340/360°C), improving thermal stability

334

GC a

nd G

C/M

S

www.agilent.com/chem/supplies

ProSteel Deactivated Fused Silica

ID (mm) OD (mm) Length (m) Part No.

0.53 0.67 5 160-4535-5

Deactivated Fused Silica High Temperature (400°C)

ID (mm) OD (mm) Length (m) Part No.

0.05 0.36 5 160-2815-5

0.10 0.36 5 160-2825-5

0.25 0.35 5 160-2845-5

10 160-2845-10

0.32 0.43 5 160-2855-5

10 160-2855-10

0.53 0.67 5 160-2865-5

10 160-2865-10

Undeactivated Fused SilicaUndeactivated tubing or bare fused silica is commonly used for capillary electrophoresis. It can also be used for transfer lines and other applications where inertness is not critical.

Undeactivated Fused Silica

ID (mm) OD (mm) Length (m) Part No.

0.02 0.36 5 160-2660-5

0.05 0.36 5 160-2650-5

10 160-2650-10

0.075 0.36 5 160-2644-5

10 160-2644-10

0.10 0.36 5 160-2634-5

10 160-2634-10

0.18 0.34 5 160-2610-5

10 160-2610-10

0.20 0.36 5 160-2200-5

10 160-2200-10

50 19091-20050

0.25 0.36 5 160-2250-5

10 160-2250-10

0.32 0.43 5 160-2320-5

10 160-2320-10

50 19091-21050

0.45 0.67 5 160-2450-5

10 160-2450-10

0.53 0.67 5 160-2530-5

10 160-2530-10

Fused Silica Tubing