ge evolve outdoor led lighting fixtures flood light wall ... · the evolve™ led wall and...

4
GE Lighting Solutions Wall and Underpass Flood (EFMU) Evolve LED Flood Light imagination at work

Upload: others

Post on 07-Feb-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

GELighting Solutions

Wall and Underpass Flood (EFMU)

Evolve™ LED Flood Light

imagination at work

Applications

• General flood requirements, roadway underpasses and pedestrian tunnels utilizing advanced refractive LED optical system providing high uniformity, excellent light distribution.

Housing

• Cast aluminum housing.• Functional design incorporates heat sink to ensure maximum heat transfer and long LED life. • Meets 2G vibration standards per ANSI C136.32-2001.

Led & Optical Assembly

• Structured LED arrays for optimized photometric patterns. • Refractors designed to optimize application efficiency. • Utilizes high brightness LEDs, 70 CRI at 6000K. • LM-79 tests and reports are performed in accordance with IESNA standards.

Lumen Maintenance

• System rating is L70 at 50,000 hours

Ratings

• listed, suitable for wet locations. • IP 66 rated optical and electrical enclosure per ANSI C136.25-2009. • Temperature rated at –40° to 40°C.

Mounting

• Wall or ceiling mount.

Finish

• Corrosion resistant polyester powder painted, minimum 2.0 mil. thickness. • Standard color: Gray.• Additional colors available with minimum order quantities and extended lead times.

Electrical

• 120 volt electronic driver. 200-277 volt available with extended lead times.• System power factor is >90% and THD <20%.• Class “A” audible sound rating.• Integral surge protection per IEEE/ANSI C62.41.2-2002, 6kV/3kA Location Category C-Low

Warranty

• 5-year limited system warranty standard.

The Evolve™ LED Wall and Underpass Flood is ideal for simple wall flood applications or for bridge underpass where no maintenance is required. This luminaire features an advanced LED optical system that provides improved lighting control versus a standard HID general flood to optimize distribution to meet photometric requirements. This fixture offers convenient mounting options for both vertical wall surfaces and horizontal ceilings to cover any mounting application required.

The Evolve LED Wall and Underpass Flood offers up to a 50-percent reduction in system energy compared with standard HID systems, depending on applications. This reliable system also offers more than 11 years of service life to significantly reduce maintenance frequency and expense, based on a 50,000 hour life and 12 hours of operation per day. And with an IP66 rating, this robust fixture can be easily sprayed down for cleaning.

Product Features

E F M U 6 0 G 0 S G X X X_ _ _ _ - _ - _ _ - _ _ - _ - _ - _ - _ _ - _ _ _

PROD. ID VOLTAGE FIXTURELENS TyPE

LED COLOR TEMP

OPTICALCODE

1 = 120G = 200-277*

*Consult factory for lead time

OPTIONS

XXX = Special Options

For other gauge wires, order separate kit below.

G =Tempered Glass

COLOR

SG = Silver Gray

PE FUNCTION

0 = None (not available)

MOUNTING ARM

W = Wall BracketC = Ceiling Bracket

60 = 6000KE = LED

F = Flood

M = Medium

U = Underpass

OPTICAL CODE

TyPE200-277V100-127V

SUGGESTED UNDERPASS

APPLICATIONSIES FILE NUMBER

6000KMOUNTING

STyLE

AM Asymmetric Medium 5400 90 90 3-4 Lanes Wall Mounted 454621

AW Asymmetric Wide 5400 90 90 3-4 Lanes Wall Mounted 454622

SY Symmetric 5400 90 90 3-4 Lanes Ceiling Mounted 454623

Ordering Number LogicWall and Underpass Flood (EFMU)

6000K

TyPICAL INITIAL LUMENS

TyPICAL SySTEM WATTAGE

Other Wire Gauge OptionsThis unit comes standard with a 16 gauge, 6 ft long wire.

To order another gauge wire, please specify one of the following that is field attached:

• EFMU-CABLEPAK-12 Comes with a 12 gauge 6’ cable, grommet and knock out plug

• EFMU-CABLEPAK-14 Comes with a 14 gauge 6’ cable, grommet and knock out plug

Photometrics

2964

2223

1482

2

1

741

3690

2460

2

1

4920

1230

2354

1569

2

1

785

3138

Grid Distance in Units of MH at 16’ and 45° tilt

Grid Distance in Units of MH at 16’ and 45° tilt

Grid Distance in Units of MH at 16’ and 45° tilt

Polar Trace Vertical and Horizontal Plane through Horizontal Angle of Maximum

Candlepower

Polar Trace Vertical and Horizontal Plane through Horizontal Angle of Maximum

Candlepower

Polar Trace Vertical and Horizontal Plane through Horizontal Angle of Maximum

Candlepower

EFMU Asymmetric Medium (AM) 5,400 Lumens, 6000K (GE454621.ies)

EFMU Symmetric (Sy)5,400 Lumens, 6000K (GE454623.ies)

EFMU Asymmetric Wide (AW) 5,400 Lumens, 6000K (GE454622.ies)

.1

.1

.2

.2

.5

.5

.1.2

.5

OLP-2899 (Rev. 11/28/12)

GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com 1 - 8 8 8 - 6 9 - 4 3 - 5 3 3

GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Evolve and the GE brand and logo are trademarks of the General Electric Company.© 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

• Approximate Net Weight: 33 lbs (15 kgs)• Effective Projected Area: 0.95 sq ft max (0.09 sq m)

DA

TA

Product Dimensions

Ceiling Mounted

Wall Mounted

10.8 in. (275.3 mm)

10.5

in. (

266

mm

)

10.2

in. (

258

mm

)

5.75

in. (

146

mm

)

9.6

in. (

243

mm

)

19.4 in. (491.5 mm)

BACK VIEW FRONT VIEW

SIDE VIEWTOP VIEW

20.25 in. (514 mm)

11.8

in. (

300

mm

)

0.75 in. (20 mm)

020

40

6080

8.75

in. (

223

mm

)12.6 in. (321 mm)10.8 in. (275.3 mm)

11.7

in. (

296

mm

)

6.5

in. (

165

mm

)

5.5

in. (

139

mm

)3.

66 in

. (93

mm

)4PCS-M8*28

4PCS-M10*40

12.7 in. (323 mm)

4PCS-M10*40

4PCS-M8*28

9.7

in. (

246

mm

)

5.5

in. (

139

mm

)3.

66 in

. (93

mm

)

3.3 in.(83.9 mm)

FRONT VIEW

SIDE VIEWTOP VIEW

BACK VIEW

11.8

in. (

300

mm

)

20.25 in. (514 mm)10.8 in. (275.3 mm)

19.4 in. (491.5 mm)

6.4

in. (

162

mm

)

10.2

in. (

258

mm

)

10.5

in. (

266

mm

)

9.6

in. (

243

mm

)

9.4 in. (240 mm)

2.75

in.

(70

mm

)

40 4020 200