  • Before you begin - Read these instructions completely and careflllly.

    IMPORTANT - Save these instructions for local inspector's use.IMPORTANT - OBSERVE AI,L GOVERNING (;ODES AND ORDINANCES.

    Note to Installer - Be sure to leave these instructions with the Consumer.

    Note to Consumer - Keep these instructions with your Owner's Manual for flmne reference.

    WARNING: This appliance must be properly grounded. See "Electrical Supply," page 5.

    If you have a question concerning theinstallation of this product, call the GE AnswerCenter ® Consumer Information Service at

    800.626.2000, 24 hours a day, 7 days a week.

    If you received a damaged vent hood, youshould immediately contact your dealer orbuilder.

    For Monogram local service in your area,1.800.444.1845.

    For Monogram service in Canada, call1.888.880.3030.

    For Monogram Parts and Accessories, call1.800.626.2002.

    (;cAUTION!

    Due to the weight and size of this vent hoodand to reduce the risk of personal i_jury ordamage to the product, TWO PEOPI,E AREREO,.UIRED FOR PROPER INSTAI,I,ATION.

    Proper installation is the responsibility ofthe installer. Product failure due to improperinstallation is not covered under the GE

    Appliance _¥arranty. See the Owner'sManual for warranty information.

    _i_SkRNING:To reduce the risk of fire or elecuical

    shock, do not use this hood with any externalsolid-state speed conuol device. Any suchalteration flom original factory wiring couldresult in damage to the unit and/or createan elecuical safety hazard.

    To reduce the risk of fire and to properlyexhaust air, be sure to duct air outdoors. Do

    not vent exhaust air into spaces within walls orceilings or into attics, crawl spaces or garages.

    _i_SkRNING: TO REDUCE THE RISK OF FIRE,USE ONIX METAl, DUCTWORK

    TO REDUCE THE RISK OF FIRE,

    EI,ECTRICAI, SHOCK OR INJURY TOPERSONS, OBSERVE THE FOI,I,OWING:

    A. Use this unit only in the manner intendedby the manufactureL If you have anyquestions, contact the manufacturer.

    B. Before servicing or cleaning unit, switchpower off at the service panel and lock servicepanel to prevent power flom being switchedon accidentally. If the service panel cannot belocked, fasten a tag or prominent warninglabel to the panel.

    For general ventilating use only. Do not useto exhaust hazardous or explosive materialsor vapors.

    Structural flaming, installation work andelecuical wiring must be done by qualifiedperson (s), in accordance with all applicablecodes and standards including fire-ratedconstruction.

    Sufficient air is needed for proper combustionand exhausting of gases through the flue(chimney) of tirol burning equipment toprevent back drafting. Follow the heatingequipment manufacturer's guidelines andsafety standards such as those published bythe National Fire Protection Association

    (NFPA), and the American Society forHeating, Refligerafion and Air ConditioningEngineers (ASHRAE), and the local codeauthorities.

    I,ocal codes vary. Installation elecuicalconnections and grounding must complywith applicable codes. In the absence oflocal codes, the vent should be installed inaccordance with National Electrical (;ode

    ANSI/NFPA 70-1990 or latest edition.

    Contents Model Available ............................................ 3Required Accessory ...................................... 3

    Recirculating Operation .............................. 3Product Dimensions ..................................... 3

    Using Duct Cover Accessories ..................... 4Installation Preparation

    Tools and Materials Required ..................... 5Power Supply ................................................ 5

    Duct Fittings ................................................. 6Step 1, Advance Planning ........................ 7, 8Installation

    Step 2, Remove the Packaging .................... 9

    Step 3, Check Installation Hardware .......... 9

    Step 4, Mount Template ............................ 10Step 5, Install Support Frame .................... 10

    Step 6, Secure Wiring ................................ 11Step 7, Size and Install Ductwork .............. 11

    Step 8, Install Decorative Duct Covers ..... 12Step 9, Install Hood ................................... 13

    Step 10, Connect Electrical ....................... 13Step 11, Slide Duct Cover Down,

    Install Side Utility Bars ................ 14

    Step 12, Install Filters ................................. 15Step 1,3, Finalize Installation ..................... 15

  • Design Intormation

    36" Island Vent Hood

    ModelAvailable

    Model This vent hood is designed toZV850 be used in vented ceiling mounted

    installations.

    NOTE: Accessories to meet properceiling height are required to completethe installation.

    RequiredAeeesso U

    ZX858 - Fox 8 ft. ceiling height.This kit includes decorative duct covers and

    support flames to reach an 8 ft ceiling height.

    ZX859 - Fox 9 ft. ceiling height.This kit includes decorative duct covers and

    support flames to reach an 9 ft ceiling height.

    ZX8510 - Fox 10 ft. ceiling height.This kit includes decorative duct covers and

    support flames to reach a 10 ft. ceiling height.

    Order the required accessox y at the same timeas the vent hood and have on site before

    installation.

    ReeireulatingOperation

    This hood may be installed for recirculadngoperation. One of the following kits isrequired and must be ordered with the hood.ZXR858 - For 8 ft. ceiling height.ZXR859 - For 9 ft. ceiling height.ZXR8510 - For 10 ft. ceiling height.

    Both the hood and accessory must beon site at the time of installation. Follow

    the installation insuuctions packed with

    the accessory to complete the installation.

    Product

    Dimensions

    The vent hood must be installed 24" rain. and

    30" max. above the cooking surface. 25-1/2" isrecommended for best venting performanceand to insure that the duct cover meets the

    ceiling. The cooking surface should be at least36" above the floor. Installation will be easier if

    the vent hood is installed before the cooktopand countertop is installed.

    "25-1/2" Recommended

    *He ght

    ] to Ceiling

    *26-1/4"for8 ft. Ceiling

    UsingZX858Accessory

    38-1/8"for9 ft. Ceiling

    UsingZX859Accessory

    50-1/8"for 10ft. Ceiling

    UsingZX8510Accessory

    36"Reference

    Thedistance between the cooking surface and the bottom

    of the hood must be at least 24" and upto 30". The 25-1/2"

    recommended installation height, above the standard36"

    countertop, will insure duct cover fit to the ceiling.

  • Design Intormation

    36" Island Vent Hood

    Usinff DuctCover Accessories

    A duct cover accessory is required for all

    ceiling heights. Use this chart to determine the

    correct Duct Cover Accessory for 8 ft. to 10 ft.

    ceilings that must be ordered with the hood.

    ZV850SBInstallation HeightsActual

    Ceiling * PossibleHoodHeight Installation Height

    7' 11" 24-1/2"

    8'0" 25-1/2"

    8' 1" 25-1/2"t0 26-1/2"

    8' 2" 25-1/2"t0 27-1/2"

    8' 3" 25-1/2" t0 28-1/2"

    8' 4" 25-1/2" t0 29-1/2"

    8' 5" 30" max.

    8' 6" 30" max.

    8' 7" 30" max.

    8' 8" 30" max.

    8' 9" 30" max.

    8' 10" 30" max.

    8' 11" 30" max.

    9' O" 30" max.

    9' 1" 30" max.

    9' 2" 30" max.

    9' 3" 30" max.

    9' 4" 30" max.

    9' 5" 30" max.

    9' 6" 30" max.

    9' 7" 30" max.

    9' 8" 30" max.

    9' 9" 30" max.

    9' 10" 30" max.

    9' 11" 30" max.

    10' O" 30" max.

    Duct Cover

    Accessory

    >-

    o o3co

    coIJJ ¢ooX_.3 N

    mC.0O3

    C0xN>-et-o

    uJ

    -n-oo3o3uJcoco

  • Installation Preparation

    36" Island Vent Hood

    7bols andMaterials

    Required(not supplied)

    • Tapemeasure• Knife

    • Spirit level• Wire cutter

    • Wire stripper• Wire nuts

    • Electric drill and 5/32" bit• Phillips screwdriver• Flat blade screwdriver• Hammer• Pliers

    • 10 mm Hexwrench/socket• Safety glasses• Tapeto mount template• Glovesto protect against sharp edges

    • 120V60Hz.15 or 20 Amp, 2 wire with ground.Properlygrounded branchcircuit.

    • Strain relief for junction box cover.• Plumb

    • Center punch

    IMPORTANT- (Please read careflflly)

    FOR PERSONAI, SAFETY, THISAPPI,IANCE MUST BE PROPERIX(;ROUNDED.

    Remove house flase or open circuit

    breaker before beginninginstallation.

    Do not use an extension cord or adapter

    plug with this appliance. Follow NationalElecuical Code or prevailing local codesand ordinances.

    Grounding Instructions

    The grounding conductor must be connected

    to a ground metal, permanent wiring system,

    or an equipment-grounding terminal or leadon the hood.

    Electrical supplyThis vent hood must be supplied with 120V,60Hz, and connected to an individual,

    properly grounded branch circuit, andprotected by a 15 or 20 amp circuitbreaker or time delay flase.• Wiring must be 2 wire with ground.• If the elecuical supply does not meet

    tim above requirements, call a licensedelecuician before proceeding.

    • Rotate house wiring in the ceiling, asclose to the installation location as possible.Allow an additional 3 feet length flomceiling joists to reach the junction boxon the hood.

    • Connect the wiring to the house wiring inaccordance with local codes.

    Warning: The improperconnection of the equipment-grounding conductor can result ina risk of elecuic shock. Check with

    a qualified elecuician or servicerepresentative if you are in doubt whetherthe appliance is properly grounded.

  • Installation Preparation

    36" Island Vent Hood

    Duct

    fittincs

    Use this chart to

    compute maximum

    permissable lengthsfor duct runs to

    outdoors.

    Note: Do not exceed

    maximumpermissableequivalent lengths!

    Maximumductlength:100footforrangehoods.

    Flexible ducting:If flexible metal

    ducfing is used, all

    the equivalent feetvalues in the ruble

    should be doubled.

    The flexible metal

    duct should be

    straight and smoothand extended as

    much as possible.

    Do NOT use flexible

    plastic ducfing.

    Note:Any homeventilationsystem, suchas a ventilationhood, may interrupt the properflow of combustion air and

    exhaust required by fireplaces,gas furnaces, gaswater heatersand other naturally ventedsystems. Tominimize the chanceof interruption of such naturallyvented systems,follow theheating equipmentmanufacturer'sguidelines andsafety standards such asthosepublished by NFPAand ASHRAE.

    Duct Piece Dimensions

    Ro t/Ild,

    straight

    /_ 3-1/4" x 10"straight

    Q_ 90 ° elbow 12 It.

    45 ° elbow 7 It.

    3-1/4" x 10" 14 ft.3-1/4" x 12" 10 It.

    90 ° elbow

    @_ 3-1/4" x 10" 8 ft.3-1/4" x 12" 6tt.

    45 ° elbow

    3-1/4" x 10" 33 It.3-1/4" x 12" 24 It.

    90 ° fiat elbow

    _@,_ 6" I'ound torectangular 2 It.

    Equivalent QuantityI,ength* Usedlit.

    (per foot

    length)

    lit.

    (per fbot

    length)

    _1_ Rectangularto 6" round 2 It.

    _ 3-1/4" x l 0" 4 ft.3-1/4" x 12" 4 ft.6" I'Ot/Ild to

    rectangular

    transition 90 ° elbow

    _ 3-1/4" x 10" 4 ft.3-1/4" x 12" 4ft.

    Rectangular to 6" roundtransition 90 ° elbow

    Roundwall cap

    with dainper 24 ft.

    3-1/4" x 10" 24 ft.3-1/4" x 12" 18 ft.

    Rectangular wall cap

    with damper

    Round roof cap 33 ft.

    _Actual length of straight duct plus duct fittingequivalent. Equivalent length of duct pieces are basedon actual tests conducted by GEEvaluation Engineeringand reflect requirements for good venting performancewith any ventilation hood.

    Total Duct Run __

    Total

    Equivalent

    I,ength

  • Installation Preparation

    36" Island Vent Hood

    Advance

    Planning

    Plan the locationDetermine the exact location of the vent hood.

    • Use a plumb to check location to be surecountertop/cooktop location below the hoodwill align exacdy.

    • The hood should project forward 1-1/2"beyond the flont edge of the cookingappliance. See illusuadon.

    • Observe the recommended 25-1/2" spacebetween the cooking surface and bottomof hood.

    Front

    Ceiling

    i Hood

    I :....]z D_ttinllne

    Jl..............................27_1/2_.........................

    i i

    Approx.1-1/2''_"

    BeyondCookingSurface

    I

    Cooktop/'//

    I

    ___- Countertop

    SideView

    "7-5/8"

    8-3/4" ,Cross 1

    i

    Framing 1iii

    , 1B"

    i ii ii ii i

    TopView of SupportFraming

    i ii ii i

    i+li ii i

    i

    i

    i

    /!

    i

    i

    i

    TypicalSupportFrameMounting

    *The framing should be spaced 8-3/4" on the sidesand 7-5/8" at thefront from centerline to centerline to accept mounting screws inthe

    vent support frame.

    ii

    Frontof

    Hood

    Cross

    _ Framing

    ,-'_8-3/4"_;i i

    Side Iv_ew I

    \\\

    Upper

    Lower f

    Ceiling/

    /

    SupportFrames

    Ceiling support structure• At the hood location, install 2 x 4 cross

    flaming between ceiling joists as shown.• The 2 x 4 cross flaming can be installed

    standing or fiat, depending on duct run.See illusuadon of ductwork, page 8.

    Note."The cross framingmust be spaced 8-3/4" onthe side from centerlineto centerline in order to

    accept the hood mountingscrews.

  • Installation Preparation

    36" Island Vent Hood

    s1Advance

    Planning

    (continued)

    • Arrange cross flatning in tile ceiling to suittile existing structure. See examples.

    - Secure each 2 x 4 block with at least four (4),#10 wood screws, 3" long (minimum sizescrews, not supplied). Use 8 wood screwstotal for tile two supports.

    • The cross framing must be accuratelyaligned to assure correct positioning ofthe hood.

    • The cross framing must be level in alldirections. Check with a spirit level andadjust if necessary.

    IMPORTAN#The ceiling structure must be capable of supportingthe weight of the hood(approximately 100 pounds)and anyinadvertent usercontact loads. It is recommendedthat the hood

    support frame be supportedby a minimum of 2 x 4 cross framing.

    CrossFramingb,

    Ceil

    Joist __Hood

    Support-- _ Frame

    Opening

    1 :t

    UpperHalfOfSupport

    Frame

    Height ....Adjustment

    Slot

    Ductwork

    • Use tile shortest and suaightest duct routepossible. For satisfactory performance, ductrun should not exceed 100 feet equivalentlength for any duct configuration.

    • Refer to "Duct Fittings" chart to compute tilemaxilnum permissible length for duct rtmsto tile outdoors.

    • This vent hood must use 6" round duct. Tile

    6" round duct can transition to 3-1/4" x 10"or 3-1/4" x 12".

    • Install tile house ductwork to run

    horizontally between ceiling joistsor suaight tap through tile roof.

    Finish the CeilingFinish tile ceiling surface. Be sure to marklocadon of the ceiling joists and cross flaming.Check to be sure that ceiling is level, use shimsif necessary.

    • ....... Ii ii ii ii

    G"

    CeilingJoint

    ........)_ 2x4

    Vent Straight Up

    ThroughTheCeiling

    DuctElbow

    2Standing

    VentBetweenCeilingJoists

  • Installation

    36" Islan, d Vent Hood

    Remove the

    Paekacin¢

    The vent hood is packed separately flom therequired accessory ZX858, ZX859 or ZX8510.• Remove the flame, cove_; parts box, side bars

    and packaging.• Remove junction box cover.• Install suain relief onto junction box coveL

    CheekInstallationHardware

    I,ocate the hardware accesso_ T box packedwith the hood and check contents.

    E

    4 Flat Washers

    4 Hexhead

    wood lag screws(6mm x 2-1/2")

    or

    (1/4 x 2-1/2")

    3 Filters

    g2 Phillips Head

    Decorative Screws

    8 FrameAttachmentScrews with Washers

    (attachedtoaccessorysupport

    frames)

    /o o \

    N° Frontof Hood o/

    " Q) "\ /

    Template

    4 (lOmm) Nuts and LockWashers

    2 Side Bars With 4 Machine Screws

    _ heck service manual envelope taped

    to the front of the hood to be sure it

    contains one stop screw. Leavethisscrew in the envelope.

    Check contents of the required

    accesso_T, ZX858, ZX859 or ZX8510.

    Support Frameswith 8 Screwsand 8 Washers

    MountingScrewHoles

    Decorative Duct Covers

  • Installation

    36" Island Vent Hood

    Template

    Install

    SupportFrame

    • Align the template with the marks on theceiling and tape in place.- Be sure the template is oriented correctly,

    with the fiont of the hood.

    • Use a plumb to be sure the mounting holeswill provide parallel alignment with thecountertop below.

    • Center punch all hole locations.• Drill pilot holes in the 4 screw locations.

    Use a 5/32" bit and drill approximately1-1/2" deep.

    • Cut the 6-1/4" dia. duct opening and approx.1" dia. wire access hole.

    /o o \

    o FrontofHood

    \\ 0 /

    ". ..... /-" WireAccessHole

    Upper 'Support FrorFrame Of

    Hoc

    !!

    '-L_.__..

    . SupportFrame

    Opening

    CheckLevelinBothDirection

    LowerSupport .........-i:....Frame

    Hood.. ..... LowerSupportwlountlng_Flange ", ,, ........................

    ._d_"A:7._"-_.. 13-5/8

    ]

    25-1/2"Recommended

    Countertop

    "39-1/8"

    *'75-1/8"to Floor

    1o

    Install upper support frame

    • Secure the upper support flame to the

    ceiling joists and/or cross flaming with the

    4 screws provided. For maximum rigidity

    and strength, the screws must be driven

    into the center of the joists and/or cross

    flaming.

    • Check to be sure the support frame is

    level, vertically and horizontally.

    *!ilote:39-1/8" to top of hood flange can be increasedup to 42" max.

    *'75-1/8" rain. to floor, 77-7/8" max.

    Install lower support frame• Insert lower support flame (flom required

    accessory ZX858, ZX859 or ZX8510) into theupper support flame and loosely secure with8 screws and washers (4 on flont and 4 onback sides).

    • Adjust the lower support flame up or downto the desired height above the countertop.Tighten screws.

    Important: Again, check to be sure the supportis level in both directions. There is no wW tolevel the hood after the hood is secured tothe flame.

  • Installation

    36" Island Vent Hood

    Wiring• Route house Mring through the ceiling hole

    and pull a length to reach the hood junctionbox, approximately 6" below the support.

    • Tape the wire to the flont of the flamesupport to prevent damage duringinstallation and service.

    FrontSide

    SupportFrames

    # Ce!ling

    r77 _

    '\\\

    ? ?

    o o )Tape? ? /

    /

    /.J

    :- House\^I;4%

    s,e7Size AndInstall

    Duetworh

    To Find Required Duct Length:• Measure flom house duct flange to bottom

    of support flame. (Dimension A)- Add at least 1" to Dim. A for duct overlap

    at the top.- Submmt 1-3/4" for hood insertion into the

    bottom of the flame to determine requiredduct length.

    • (;tat the 6" duct to required length.Note: The bottom of the duct must be external

    (female) connection to the top of the hood.The bottom end should be flared slightly, tofacilitate installation of the hood.

    • Install duct tap through support flames andattach to house ducting with sheet metalscIews.

    • Seal the connection with duct tape.

    HouseDuct....

    DuctConnectionToHood........

    SideView

    SupportFrame

    BottomSupportFrameFlange

    11

  • Installation

    36" Island Vent Hood

    Se8InstallDecorative

    Duct Covers

    Pretap2 Screw /Holes

    .1

    /

    i-lf_

    Top DuctCover

    InstallScrewonEachSide

    TopDuctCover

    TopDuctDover

    BottomDuctCover

    Bottom Duct Cover

    // --\\\

    ,,,(Stop Screw oX.....

    Install StopScrew in Oneof 3 Holes

    • Premp or drive decorative screw into thescrew holes on the support flame. This willmake screw installation easier.

    • Separate the two decorative duct covers.• Select the inside (top) covet, which has two

    screw holes in the top.• Slide the decorative duct covet over the

    support flame and push to the ceiling.• Attach to the hood support at the top with

    2 supplied decorative screws.

    • I,ocate the stop screw in the envelope tapedto the flont of the hood. Set aside.

    • Slide the bottom decorative duct over the

    installed top duct and push tap past the stopscrew hole location.

    • Install the supplied temporat T stop screw

    in one of 3 holes in the support flame or

    the top duct covet to prevent the bottom

    decorative duct covet flom sliding down.

    The stop screw must beinstalled. Failure to do so could result in

    personal injury or damage to the ductcover.

    12

  • Installation

    36" Island Vent Hood

    InstallHood

    Align DuctConnectorto ..HouseDuct

    / AlignMountingStuds

    Bottom I

    gU?tr j

    StopScrew __ o / Install --l /4,ockH II[ot _ --1 J washer

    • _ 4 Nuts

    Note: TWO PEOPLE ARE REQUIRED TOCOMPLETE THIS INSTALLATION!

    • I,ifl the hood up to the support frame.

    Carefldly align tim hood mounting studs

    into the support flame holes, and at tim

    same time, guide tim hood duct connectorinto tim house duct.

    • Install 4 nuts and lock washers to the

    mounting studs. Tighten with a 10mmwrencll.

    • Check hood level in both directions.

    • Check to be sure that the duct is positionedover tim hood connectoL

    • Seal tim duct connection with duct rope.

    Note: Do not drive screws through lower duct

    connection. Doing so will prevent proper

    damper operation.

    10Connect

    Electrical

    Verify that power is turned off at the source.

    If house wiring is not 2-wire with

    a ground wire, a ground must be

    provided by the insmlleL

    When house wiring is aluminum,

    be sure to use U.I,. approved

    anti-oxidant compound and

    aluminum-to-copper connectors.

    • Install strain relief into tim knockout of tim

    junction box coveL

    • Insert house wiring through strain relief and

    tighten.• Connect white leads to branch circuit white

    lead.

    • Connect black leads to branch circuit black

    lead.

    • Connect green/yellow leads to branch

    circuit green or bare ground lead.• Secure all connections with wire ntlts Oil

    each elecuical connectoL

    • Push wires into junction box and replace

    coveL Be sure wires are not pinched.

    13

  • Installation

    36" Island Vent Hood

    Slide Duct

    Cover Down,Install Side

    Utility Bars1

    JJ

    • Hold the deco_afive duct cove_ and

    _emove the tempora_y stop sc_ew. Retmnthe sctew to the seevice manual envelopefoi fllttl_e use.

    • Slide the lower duct cover down ontothe hood.

    • Install the side utility ba_s with screwsas shown.

    14

  • Installation

    36" Island Vent Hood

    InstallFilters LowerFilter

    Slots

    \\\\\

    • Remove protective film on filters.

    • Tip the filter into the lower slots at the rear

    of the opening. I,ift the filter and pull theknob forward until the filter rests on the

    slots.

    • To remove the filters, grasp the knob,

    push the filter towards the rear and flitdownwards.

    e 13FinalizeInstallation

    • Remove the protective film covering theconuol panel on the flont face of the hood,and any other packaging materials.

    • Check all 4 lamps to assure dghmess insockets.

    • Refer to the Owner's Manual for

    operating insuuctions.

    15

  • Monogram:GEConsumer& IndustrialGEAppliancesGeneralElectricCompanyLouisville,KY40225

    monogram, com

    5")2007 GE Company

    NOTE: While performing installations described in this

    book, safer} glasses or goggles should be worn.

    I+br Mo_og'ram local service i_ )'our area, call1.800.444.1845.

    NOTE: Prod/let impro\vment is a continuing endea or at General Electric.

    There[k_re, materials, appearance and specifications are s/ll_ject to change

    witho/lt notice.