ge - mpact mpro acb ( 400a - 4000a )
TRANSCRIPT
M-PACTAir Circuit Breaker 400-4000A
New
GE EnergyIndustrial Solutions
M-PACTAir Circuit Breaker 400-4000A
INDEX
Technical OverviewA
B
Fixed Circuit Breaker .............................................................................................................................................................................. A.4
Withdrawable Circuit Breaker ........................................................................................................................................................... A.6
Characteristics .......................................................................................................................................................................................... A.7
State-of-the-Art Electronic Trip Units ............................................................................................................................................. A.9
Time Current Curves ............................................................................................................................................................................A.11
M-PACT Accessories .............................................................................................................................................................................A.19
Mpro 27 & 50 Connection ....................................................................................................................................................................B.2
Dimensional Drawings ...........................................................................................................................................................................B.6
Wiring DiagramsDimensional Drawings
M-PACT
A.3 Technical overview
Notes:
A.4Technical overview
Specification
Approvals
Rated from 400 to 4000A the M-PACT circuit breaker has been designed to meet the most stringent demands in fault detection and safe interruption thereof.
Available in 2 frame sizes:- frame size 1 ranging from 400 to 2500A- frame size 2 ranging from 800 to 4000A
The range has been developed to be aestheticallyand technically co-ordinated with other protectivedevices within the GE Power Controls industrialproduct ranges.
The breaker range has a common height and depth andis available in both fixed pattern and drawout versionswhich can be manually or electrically operated.
Designed to offer multiple mains connection options italso comes with a wide range of easy-to-install accessories.
M-PACT Air Circuit Breakers comply with the followingspecifications for Low Voltage Switchgear:
IEC 60947-1• IEC 60947-2• IEC 60947-3• Utilisation category B•
KEMA certification in accordance with IEC 60947-2CCC certification in accordance with GB14048-2CCS certification in accordance with China Certification of shipping
3 performance ranges*A -50 kA (Icu)D -65 kA (Icu)H1, H2 -80 kA (Icu)*Ratings shown at 415V AC2 compact frame sizesFrame size 1 - 400 to 2500AFrame size 2 - 800 to 4000AFixed pattern and withdrawable versions3 or 4 pole configurationFront and rear access connections (horizontal/vertical)Devices provided with or without protection relayManual or electrical operationCommon height and depth dimensionsBuilt-in safety features e.g. safety shuttersWide range of protection settings offering full selectivityCombinations of earth fault protectionEasy-to-install accessories, common to entire rangeSimple and efficient servicing on site
Type A Type D Type H1,H2
Fixed Circuit Breaker
M-PACT
A.5 Technical overview
Fixed Circuit BreakerAll M-PACT fixed pattern Air Circuit Breakers incorporate a stored energy mechanism. The spring can be charged either manually or electrically via a motor operator that is automatically activated after the closing operation.
IP43 front panel and door escutcheon seals are standard features with IP20 protected secondary isolating contacts.
For enhanced protection, an optional IP54 door panel is also available.
Trip-free operating mechanism• Positive 'ON/OFF' contact indication• Mechanical/electrical anti-pumping device• Charging spring status indication (optional)• Ergonomic manual spring charging handle• Field-mountable range of accessories• Auxiliary switches 5 NO and 3 NC, 10A 250V (standard)• Mechanical trip alarm switch (1NO) (optional)• Padlockable push-button cover• Mechanical cable interlocking (optional)• Termination: rear, horizontal or front access (optional)• Electrical clearances according to IEC60947-2• Front access of secondary terminals for simple connection•
8
9
InstallationFixed pattern M-PACT can be fastened into any suitable switchboard or cubicle arrangement using four M8 bolts.
Clearance is only required above the unit for the removal and inspection of the arc chutes (see dimensional drawings for mounting details and recommended clearance distances).
An earthing point is provided on either side of the circuit breaker.
Power Supply
1. Motorised spring charging unit (optional)2. M-PRO Protection Relay (optional)3. Secondary contacts4. Shunt trip (optional)5. Closing coil (optional)6. Undervoltage release (optional)7. Manual charging handle8. ON/OFF push-buttons9. Push-button padlockable covers10. Positive contact indication11. Charging spring status indication12. Mounting plate
12
3
2
7
10
11
4 5
1
6
A.6Technical overview
8 6
Withdrawable Circuit Breaker
Insulated, earthed steel shutters to isolate the main • contact zone
Front access padlocking for safety shutters• Secure padlocking in the "Disconnect" position• Clearly visible operational position indication• Carriage position switch (optional)• Termination: Flat copper palms (standard) with captive M10 •
fixing nuts'T' terminal adaptors for horizontal/vertical connection •
(optional)Front access connections (optional)• Automatic disconnect of secondary circuits• Lifting lugs for ease of removing the circuit breaker from •
the cassetteFront access of secondary terminals for simple connection• Cassette side mounting fixing parts (optional)•
Installation
Power Supply
Circuit breakers are delivered pre-mounted in thecassette (standard)
Versatile fixing arrangements allow mounting onto any switchboard or cubicle using four M8 bolts (see dimensional drawings for mounting details and recommended clearance distances)
Earthing point situated on the right hand side of cassette (front view)
1. Carriage position switch (optional)2. Extension rail3. Earthed steel safety shutter4. Secondary terminals5. 2 way cable interlock mechanism (optional)6. Racking handle (storage)7. Padlocking for safety shutters8. Insertion hole for racking handle9. Padlocking in the DISCONNECTED position10. Operational position indication11. Key interlock (optional)
5
4
11
7
10
9
2
1
3
4
Withdrawable Circuit Breaker
M-PACT
A.7 Technical overview
Characteristics
Design and specifications are subject to changes without notice.
Selectivity
The following table shows the conditions to satisfy full selectivity between UP-STREAM and DOWN-STREAM devices. Up-stream: M-PACTDown-stream: M-PACTST delay 50 ms minimum between up-stream and downstream ACB Multipl ication coefficient between LT-ratings≥1,56
Down-stream
- 400 800 1000 1250 1600 2000 2500 3200 4000400 - - - - - - - - -800 Full - - - - - - - -
1000 Full - - - - - - - -1250 Full Full - - - - - - -1600 Full Full Full - - - - - -2000 Full Full Full Full - - - - -2500 Full Full Full Full Full Full - - -3200 Full Full Full Full Full Full - - -4000 Full Full Full Full Full 2000 Full - -
Up-
stre
am
Catalog NO.ConfigurationMP A 3 1 F 16
Ratings:
04-400A, 08-800A10-1000A, 12-1250A16-1600A, 20-2000A25-2500A, 32-3200A40-4000A
Installation: F-fixed W-withdrawable
Type: 1-Frame1 2-Frame2
* Letter 'L' & 'R' only for type selection, not shown on nameplate.
Breaking Capacity: A, D, H1, H2
M-PACT
Pole: 3-3P 4-4P*
Performance DataCharacteristic Symbol UnitsRated current (400C) 400 800 1000 1250 1600 2000 2500 3200 4000
Endurance (number of operating cycles)Mechanical (with maintenance) 20000 20000 20000 20000 20000 20000 20000 20000 20000
Mechanical (without maintenance) 10000 10000 10000 10000 10000 10000 10000 10000 10000Electrical (at rated current) 5000 5000 5000 5000 5000 5000 5000 5000 5000
Rated service voltage (50/60 Hz) Ue V 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 415 415 690 415 415 415 690Rated insulation voltage (50/60 Hz) Ui V 1000 1000 1000 1000 1000 1000 1000 1000 1000Rated impulse withstand voltage Uimp V 8000 8000 8000 8000 8000 8000 8000 8000 8000
Number of poles 3 & 4 3 & 4 3 & 4 3 & 4 3 & 4 3 & 4 3 & 4 3 & 4 3 & 4Rating of 4th pole 100% 100% 100% 100% 100% 100% 100% 100% 100%
ACB type A D A D H1 H2 A D H1 H2 A D H1 H2 A D H1 H2 A D H1 H2 A D H1 H2 A D H1 H2 A D H1 H2Frame size 1 1 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 2 2 2 2 2 2 2 2
Rated ultimate short-circuit Icu kA (rms) 220V 50 65 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80breaking capacity 415V 50 65 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80
500V - 65 - 65 - 80 - 65 - 80 - 65 - 80 - 65 - 80 - 65 - 80 - 65 - 80 - - - 80 - - - 80600V - 50 - 50 - 65 - 50 - 65 - 50 - 65 - 50 - 65 - 50 - 65 - 50 - 65 - - - 65 - - - 65690V - 40 - 40 - 60 - 40 - 60 - 40 - 60 - 40 - 60 - 40 - 60 - 40 - 60 - - - 60 - - - 60
Rated service short-circuit Ics kA (rms) 220V 50 65 50 65 80 80 50 65 80 80 50 65 80 80 50 50 65 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80breaking capacity 415V 50 65 50 65 80 80 50 65 80 80 50 65 80 80 50 50 65 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80
500V - 65 - 65 - 80 - 65 - 80 - 65 - 80 - 50 - 65 - 65 - 80 - 65 - 80 - - - 80 - - - 80600V - 50 - 50 - 65 - 50 - 65 - 50 - 65 - 50 - 50 - 50 - 65 - 50 - 65 - - - 65 - - - 65690V - 40 - 40 - 60 - 40 - 60 - 40 - 60 - 40 - 40 - 40 - 60 - 40 - 60 - - - 60 - - - 60
Rated short time withstand current1 second Icw kA (rms) 50 50 50 50 65 80 50 50 65 80 50 50 65 80 50 50 65 65 80 65 65 80 50 65 65 80 50 65 65 80 50 65 65 803 seconds Icw kA (rms) 40 50 40 50 50 50 40 50 50 50 40 50 50 50 40 40 50 50 50 50 50 50 40 50 50 50 40 50 50 50 40 50 50 50Rated short-circuit making capacity Icm kA (peak) 415V 105 143 105 143 176 176 105 143 176 176 105 143 176 176 105 105 143 176 176 143 176 176 105 143 176 176 105 143 176 176 105 143 176 176
500V - 143 - 143 - 176 - 143 - 176 - 143 - 176 - 105 - 143 - 143 - 176 - 143 - 176 - - - 176 - - - 176600V - 105 - 105 - 143 - 105 - 143 - 105 - 143 - 105 - 105 - 105 - 143 - 105 - 143 - - - 143 - - - 143690V - 84 - 84 - 105 - 84 - 105 - 84 - 105 - 84 - 84 - 84 - 105 - 84 - 105 - - - 105 - - - 105
Power dissipation at In (Fixed breaker) Watts 15 10 63 43 23 20 106 68 36 32 175 105 60 53 284 284 196 98 86 224 163 143 351 351 255 223 418 418 418 366 571 571 571 571Power dissipation at In (Withdrawable) Watts 30 21 127 86 49 43 211 135 77 68 351 211 128 113 574 574 392 209 184 490 347 306 765 765 542 478 888 888 888 783 1224 1224 1224 1224
A.8Technical overview
Weights (kg)A range D range H range
Fixed pattern ACB Frame 3 Pole 4 Pole 3 Pole 4 Pole 3 Pole 4 Pole400 to 1600A 1 39 49 39 49 / /
2000 to 2500A 1 43 54 43 54 / /800 to 3200A 2 53 68 53 68 53 68
4000A 2 53 68 53 68 53 68
Withdrawable ACB Frame 3 Pole 4 Pole 3 Pole 4 Pole 3 Pole 4 Pole400 to 1600A 1 68 79 68 79 / /
2000 to 2500A 1 74 85 74 85 / /800 to 3200A 2 90 109 90 109 90 109
4000A 2 113 128 113 128 113 128
Recommended Minimum Copper SizeIn accordance with IEC 60947-2
Rating (A) Copper / phase400 2 x 50 x 5800 2 x 50 x 5
1000 2 x 60 x 51250 2 x 100 x 51600 2 x 100 x 52000 3 x 100 x 52500 4 x 100 x 53200 4 x 100 x 104000 4 x 100 x 10 + 1 x 100 x 5
Dimensions in mmFrame
SizeRating
(A) Poles Type Height(1) Width Depth(2)
1 400 to 2500 3 Withdrawable 440 329 422Fixed 430 342 352
4 Withdrawable 440 429 422Fixed 430 442 352
2 800 to 4000 3 Withdrawable 440 419 424Fixed 430 432 352
4 Withdrawable 440 549 424Fixed 430 562 352
(1) Height is from mounting surface to highest part of the ACB.(2) Depth is from the cubicle door to the back of terminals.* 4P, Neutral on the left or right Please specified on selection form, the default
option is neutral on night.
Performance DataCharacteristic Symbol UnitsRated current (400C) 400 800 1000 1250 1600 2000 2500 3200 4000
Endurance (number of operating cycles)Mechanical (with maintenance) 20000 20000 20000 20000 20000 20000 20000 20000 20000
Mechanical (without maintenance) 10000 10000 10000 10000 10000 10000 10000 10000 10000Electrical (at rated current) 5000 5000 5000 5000 5000 5000 5000 5000 5000
Rated service voltage (50/60 Hz) Ue V 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 690 415 415 415 690 415 415 415 690Rated insulation voltage (50/60 Hz) Ui V 1000 1000 1000 1000 1000 1000 1000 1000 1000Rated impulse withstand voltage Uimp V 8000 8000 8000 8000 8000 8000 8000 8000 8000
Number of poles 3 & 4 3 & 4 3 & 4 3 & 4 3 & 4 3 & 4 3 & 4 3 & 4 3 & 4Rating of 4th pole 100% 100% 100% 100% 100% 100% 100% 100% 100%
ACB type A D A D H1 H2 A D H1 H2 A D H1 H2 A D H1 H2 A D H1 H2 A D H1 H2 A D H1 H2 A D H1 H2Frame size 1 1 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 2 2 2 2 2 2 2 2
Rated ultimate short-circuit Icu kA (rms) 220V 50 65 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80breaking capacity 415V 50 65 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80
500V - 65 - 65 - 80 - 65 - 80 - 65 - 80 - 65 - 80 - 65 - 80 - 65 - 80 - - - 80 - - - 80600V - 50 - 50 - 65 - 50 - 65 - 50 - 65 - 50 - 65 - 50 - 65 - 50 - 65 - - - 65 - - - 65690V - 40 - 40 - 60 - 40 - 60 - 40 - 60 - 40 - 60 - 40 - 60 - 40 - 60 - - - 60 - - - 60
Rated service short-circuit Ics kA (rms) 220V 50 65 50 65 80 80 50 65 80 80 50 65 80 80 50 50 65 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80breaking capacity 415V 50 65 50 65 80 80 50 65 80 80 50 65 80 80 50 50 65 80 50 65 80 80 50 65 80 80 50 65 80 80 50 65 80 80
500V - 65 - 65 - 80 - 65 - 80 - 65 - 80 - 50 - 65 - 65 - 80 - 65 - 80 - - - 80 - - - 80600V - 50 - 50 - 65 - 50 - 65 - 50 - 65 - 50 - 50 - 50 - 65 - 50 - 65 - - - 65 - - - 65690V - 40 - 40 - 60 - 40 - 60 - 40 - 60 - 40 - 40 - 40 - 60 - 40 - 60 - - - 60 - - - 60
Rated short time withstand current1 second Icw kA (rms) 50 50 50 50 65 80 50 50 65 80 50 50 65 80 50 50 65 65 80 65 65 80 50 65 65 80 50 65 65 80 50 65 65 803 seconds Icw kA (rms) 40 50 40 50 50 50 40 50 50 50 40 50 50 50 40 40 50 50 50 50 50 50 40 50 50 50 40 50 50 50 40 50 50 50Rated short-circuit making capacity Icm kA (peak) 415V 105 143 105 143 176 176 105 143 176 176 105 143 176 176 105 105 143 176 176 143 176 176 105 143 176 176 105 143 176 176 105 143 176 176
500V - 143 - 143 - 176 - 143 - 176 - 143 - 176 - 105 - 143 - 143 - 176 - 143 - 176 - - - 176 - - - 176600V - 105 - 105 - 143 - 105 - 143 - 105 - 143 - 105 - 105 - 105 - 143 - 105 - 143 - - - 143 - - - 143690V - 84 - 84 - 105 - 84 - 105 - 84 - 105 - 84 - 84 - 84 - 105 - 84 - 105 - - - 105 - - - 105
Power dissipation at In (Fixed breaker) Watts 15 10 63 43 23 20 106 68 36 32 175 105 60 53 284 284 196 98 86 224 163 143 351 351 255 223 418 418 418 366 571 571 571 571Power dissipation at In (Withdrawable) Watts 30 21 127 86 49 43 211 135 77 68 351 211 128 113 574 574 392 209 184 490 347 306 765 765 542 478 888 888 888 783 1224 1224 1224 1224
Characteristics
M-PACT
A.9 Technical overview
State-of-the-Art Electronic Trip Units
Plug'n Play MPRO-27 & MPRO-50
Main Adjustment Options
A line offering a new range of electronic trip units designed to extend and/or upgrade the • functionality offered by the existing M-PACT Plus Air Circuit Breaker.
Two types are available. The simple and effective MPRO-27 and the MPRO-50 offering extended • functionality .
Each has a LCD screen with ammeter and a menu driven setting interface, allowing a simple and • accurate setting of all parameters.
This global line of electronic trip units uses the most recent technology to offer each user an • unique combination of selectivity speed and functionality.
Electronic trip units are normally supplied factory fitted. However spares are available that can be simply plugged in to breakers installed in the field.
Each trip unit then needs to be adjusted to the required settings. If the installation is not powered up the installed battery pack or the seperately available test kit with Power Pack can be used as alternate power source.
The basic MPRO-27 type has been designed to replace the existing MPRO-17 and MPRO-18 plus units offering an extended functionality and a standard ammeter.
The MPRO-50 type replaces the existing MPRO-30 and MPRO-40 designscovering an extended functionality with protection devices as fuse links,overload protection and reduced instantaneous (RELT). Each MPRO-50 comes with a simple to connect 4 wire modbus communciation option.
LT-LTD protection •
ST-STD protection •
I-protection •
Other protection features •
Each device has an overload setting range of 0.4 to a times In and offer a choice of 22 time bands designed for use with circuit breakers.
A second set of 22 time bands shaped to match the time current curves of fuses is available on the MPRO-50 type.
A timed delayed short circuit protection is installed with a current setting of 2 to 12 times the set LT current value. The short circuit protection time can be set, at one of 17 bands ranging from 90 milliseconds to 1 second.
Optionaly this device can be set to one of three I2t curves.
A switchable and selective instantaneous protection with a setting range of 2 to 15 times the breaker rating that is programmed to wait one half cycle until the downstream device has reacted.
A host of other protection devices is availble including Ground Fault sum and Ground Fault source return (allowing UEF, SEF & REF) and a reduced instantaneous device. The reduced instanataneous device allows the user to conditionally programme the breaker to trip faster and at lower short circuit settings than it would on the standard instantaneuos device.
This RELT device allows the user to reduce the short circuit current level and its time span, thus reducing the amount of electrical energy in the direct vicinity of the breaker.
A.10Technical overview
Trip Unit MPRO-27 MPRO-50Setting InterfaceLCD screen allowing access to 4 distinct menu's X XTouch pad adjustments X XMultilingual X XAdjustable manual or automatic RESET option X XLong Time or Overload Current Protection13 current settings Ir 1, 0.95, 0.9. 0,85, 0.8, 0.75, 0.7, 0.65, 0.6, 0.55, 0.5, 0.45 & 0.4 x breaker rating In X X22 thermal protection (C type) time bands available ranging from class 0.5 to 40 (bands at 7.2 x Ir) X X22 I2t protection (F type {fuse} ) time bands available - XNeutral protection 0-50%-63%-100% X XPossibility to switch OFF - XCooling function and thermal memory X XShort Time Short-Circuit Current ProtectionSetting range from 1.5 to 12 x Ir (LT setting) X XSteps of 0.5 (a total of 22 settings) X XPossibility to switch OFF - X17 time delay settings (STDB) ranging from 30 to 940 milliseconds delay setting result ina 90 to 1000 milliseconds X X
Clearance times to IEC 40979-1 and IEC 603643 I2t Protection time bands availableInstantaneous Short-Circuit Current• StandardIi setting range from 2 to 15 x breaker rating In X XSteps of 0.5 (a total of 28 settings) X XPossibility to switch OFF X XSelective execution X XFixed instantaneous or HSIOC protection X X• ReducedIi setting range from 1.5 to 15 x Ie (primary setting) - XSteps of 0.5 (a total of 29 settings) - XPossibility to switch OFF - XRemote and local ON and OFF with position indication signal - XGround or Earth Fault ProtectionSetting range from 0.1 to 1 x In (breaker rating) (1) •(1) •(1)
Steps of 0.01 (a total of 92 settings) • •Possibility to switch OFF • •14 time delay settings (GFDB) ranging from 50 to 840 milliseconds delay setting resulting in a 110 to 900 milliseconds • •
Clearance times to IEC 40979-1 and IEC 60364 • •3 I2t protection time bands available • •1 I4t protection time bands available • •Residual principle (UEF application possible) • •Source ground return principle - •UEF, REF and SEF applications possible - •Combinations of UEF, REF and SEF applications possible - •Other FunctionsCurrent measurement (L1, L2, L3, N) X XTrip target (trip reason indication) X XTrip info (magnitude / phase) X XTrip counter X XEvent logger (trip events) X XGeneral inputs (4 availble) - XGeneral relay outputs (4 available) - XRelay based on current level (load shedding) - XGood & bad health indicator - XWatchdog - XCommunication 2 way - XModbus - X24V DC auxiliary power supply X XTest kit with power support function • •
(1) A 24V auxiliary power supply is required.KeyX = Present• = Optional- = Not possible
State-of-the-art Electronic Trip Units
M-PACT
A.11 Technical overview
Time Current CurvesExample of Full Time Current CurveTime Current Curve
The MPRO Electronic trip unit has many sophisticated setting features and an extremely broad setting range. On request we can provide complete Time Current Curves covering all installed protection devices.
The curves can be produced for any current setting within the range of the installed protection devices, for one or for a combination of two breakers.
Please contact your local GE sales office for more information.
MPRO Electronic Trip Unit
0,001
0,01
0,1
1
10
100
1000
10000
000001000010001
x Current in Amps (Strom in Ampere)
Trip
ping
Tim
e in
Sec
onds
(s)
Time Current CurveBreaker In= 2500A----------------------------------LT - Protection deviceSet at Ie= 2400AIr at 0,9 =2160ABand C-10
ST - Protection deviceSet at 6x Ir of 2160AIst=12960ABand STDB 10
I - Protection deviceSet at 12 x Ie of 2400AIi = 28800A
GF - Protection deviceSet at 0,6 x Ie of 2500A(Ig = 1500A)Band GFDB 6I²t ON & OFF
2h
7,2 x
Green & Light Blue Line = Full Clearing timeRed Line & Dark Blue Line = Non Tripping time
LT Band
ST Band
I I Band
HSIOC Band
GF Band
A.12Technical overview
Time Current Curves (cold state)LT Protection Device
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip Unit
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip Unit
ST protection - OFF
I protection set to 15 x Ie(1)
ST protection - OFF
I protection set to 15 x Ie(1)
ST protection - OFF
I protection set to 15 x Ie(1)
ST protection - OFF
I protection set to 15 x Ie(1)
LT set at Breaker Rating InSetting RangeIe= 0.975, 0.9625, 0.95, 0.45 or 0.4 x InIr= 0.5 to 1 x Ie in steps of 0.25Total Setting Range 0,2 - 1 x In
LT set at Breaker Rating InSetting RangeIe= 0.975, 0.9625, 0.95, 0.45 or 0.4 x InIr= 0.5 to 1 x Ie in steps of 0.25Total Setting Range 0,2 - 1 x In
LT set at Breaker Rating InSetting RangeIe= 0.975, 0.9625, 0.95, 0.45 or 0.4 x InIr= 0.5 to 1 x Ie in steps of 0.25Total Setting Range 0,2 - 1 x In
Time Current Curve
Band C-03Band C-08Band C-13Band C-19
LT-Protection Device-
----
Time Current Curve
Band C-06Band C-11Band C-16Band C-22
LT-Protection Device-
----
Time Current Curve
Band C-02Band C-07Band C-12Band C-17
LT-Protection Device-
----
Time Current Curve
Band C-04Band C-09Band C-14Band C-20
LT-Protection Device-
----
100002h
100002h
1000
100
10
Trip
ping
Tim
e In
Sec
onds
(s)
1
0,11,00 10,00 100,00
x Breaker Rating In
Trip
ping
Tim
e In
Sec
onds
(s)
0,11,00
x Breaker Rating In
7,2x
10,00 100,00
7,2x
Trip
ping
Tim
e In
Sec
onds
(s)
0,11,00
x Breaker Rating In10,00 100,00
7,2x
Setting RangeIe= 0.975, 0.9625, 0.95, 0.45 or 0.4 x InIr= 0.5 to 1 x Ie in steps of 0.25Total Setting Range 0,2 - 1 x In
LT set at Breaker Rating In
1000
10
100
100002h
1000
10
100
1 1
Trip
ping
Tim
e In
Sec
onds
(s)
0,11,00
x Breaker Rating In10,00 100,00
7,2x
100002h
1000
10
100
1
Time Current Curves
M-PACT
A.13 Technical overview
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip Unit
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip UnitTime Current Curve
Band STDB 02Band STDB 04Band STDB 06Band STDB 08Band STDB 19Band STDB 12Band STDB 14Band STDB 16
ST-Protection DeviceI2t - OFF-
-
--------
Time Current Curve
Band STDB 01Band STDB 03Band STDB 05Band STDB 07Band STDB 09Band STDB 11Band STDB 13Band STDB 15Band STDB 17
ST-Protection DeviceI2t - OFF-
-
---------
Green Line = Full Clearing TimeRed Line = Non Tripping Time
Green Line = Full Clearing TimeRed Line = Non Tripping Time
I protection set to 15 x Ie(1)I protection set to 15 x Ie(1)
LT set at Breaker Rating InSetting RangeIe= 0.975, 0.9625, 0.95, 0.45 or 0.4 x InIr= 0.5 to 1 x Ie in steps of 0.25Total Setting Range 0,2 - 1 x In
LT set at Breaker Rating InSetting RangeIe= 0.975, 0.9625, 0.95, 0.45 or 0.4 x InIr= 0.5 to 1 x Ie in steps of 0.25Total Setting Range 0,2 - 1 x In
Time Current Curve
Band C-05Band C-10Band C-15Band C-21
LT-Protection Device- -
----
Time Current Curve
Band C-01Band C-18
LT-Protection Device--
ST protection - OFF
I protection set to 15 x Ie(1)
ST protection - OFF
I protection set to 15 x Ie(1)
ST set on breaker rating InSetting Range1,5 to 12 x Ir in steps of 0,5
ST set on breaker rating In Setting Range1,5 to 12 x Ir in steps of 0,5
1617
15
17
15
13
11
9
7
5
3
1
13
11
9
7
5
3
1
14
12
10
16
14
12
10
8
6
4
2
8
6
4
2
x Breaker Rating In
x Breaker Rating In
x Breaker Rating In
Trip
ping
Tim
e In
Sec
onds
(s)
Trip
ping
Tim
e In
Sec
onds
(s)
Trip
ping
Tim
e In
Sec
onds
(s)
Trip
ping
Tim
e In
Sec
onds
(s)
1,00 1,00
1,00 10,0010,00 100,00100,00
x Breaker Rating In
1,00
10,00 10,00100,00 100,00
0,001 0,001
0,01 0,01
0,1
1
10
100
1000
2h10000
2h
1000
100
10
1
0,1
10000
0,1 0,1
0,2 0,2
0,4 0,4
0,6 0,6
0,8 0,8
1 1
10 10
7,2x 7,2x
-
-
Time Current Curves (cold state)LT & STDB Protection Device
A.14Technical overview
Time Current Curves (cold state)ST Protection Device
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip Unit
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip Unit
10,00 100,00
10
0,8
1
0,6
0,4
0,2
0,1
00,1
0,01
1,00
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In
10,00 100,00
10
0,8
1
0,6
0,4
0,2
0,1
00,1
0,01
1,00
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In10,00 100,00
10
0,8
1
0,6
0,4
0,2
0,1
00,1
0,01
1,00
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In
10,00 100,00
10
0,8
0,6
0,4
0,2
0,1
00,1
0,01
1,00
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In
1716 16
14
12
108
6
42
1614
12
108
6
42
14
12
10
8
6
4
2
16
14
12
10
8
6
4
2
15
1715
1313
1111
99
7
7
5
5
3
3
1
1715
1715
1313
1111
9
7
97
5
5
3
3
1
1
1
Green Iine = Full Clearing timeRed Line = Non Tripping time
Green Iine = Full Clearing timeRed Line = Non Tripping time
I protection set to 15×Ie (1)
Green Iine = Full Clearing timeRed Line = Non Tripping time
I protection set to 15×Ie (1)
I protection set to 15×Ie (1)
ST set at Breaker Rating In
1,5 to 12 × Ir in steps of 0,5Setting Range
ST set at Breaker Rating In
1,5 to 12 × Ir in steps of 0,5Setting Range
ST set at Breaker Rating In
1,5 to 12 × Ir in steps of 0,5Setting Range
- Time Current Curve
- Band STDB 01- Band STDB 03- Band STDB 05- Band STDB 07- Band STDB 09- Band STDB 11- Band STDB 13- Band STDB 15- Band STDB 17
ST- Protection Device
I2t ON “Iow”
- Time Current Curve
- Band STDB 01- Band STDB 03- Band STDB 05- Band STDB 07- Band STDB 09- Band STDB 11- Band STDB 13- Band STDB 15- Band STDB 17
ST- Protection Device
I2t ON “med”
ST set at Breaker Rating In
1,5 to 12 × Ir in steps of 0,5Setting Range
- Time Current Curve
- Band STDB 02- Band STDB 04- Band STDB 06- Band STDB 08- Band STDB 10- Band STDB 12- Band STDB 14- Band STDB 16
ST- Protection Device
I2t ON “Iow”
- Time Current Curve
- Band STDB 02- Band STDB 04- Band STDB 06- Band STDB 08- Band STDB 10- Band STDB 12- Band STDB 14- Band STDB 16
ST- Protection Device
I2t ON “med”
Green Iine = Full Clearing timeRed Line = Non Tripping time
I protection set to 15×Ie (1)
Time Current Curves
M-PACT
A.15 Technical overview
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip Unit
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip Unit
10,00 100,00
10
0,81
0,6
0,4
0,2
0,1
0,01
0,01
1,00
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In10,00 100,00
10
0,8
0,6
0,4
0,2
0,1
0,01
0,01
1,00
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In
ST set at Breaker Rating In
1,5 to 12 × Ir in steps of 0,5Setting Range
I set on breaker rating In
2 to 15 × Ie in steps of 0,5
HSIOC device HSIOC device
HI Setting RangeI set on breaker rating In
2 to 15 × Ie in steps of 0,5HI Setting Range
I set on breaker rating In
1,5 to 15 × Ie in steps of 0,5RELT Setting Range
I set on breaker rating In
1,5 to 15 × Ie in steps of 0,5RELT Setting Range
ST set at Breaker Rating In
1,5 to 12 × Ir in steps of 0,5Setting Range
1715
13
11
9
7
5 3 1
16 16
14 14
1212
1010
8
8
6
6
4 2 4 2
1715
13
11
97
5
3 1
- Time Current Curve
- Band STDB 01- Band STDB 03- Band STDB 05- Band STDB 07- Band STDB 09- Band STDB 11- Band STDB 13- Band STDB 15- Band STDB 17
ST- Protection Device
I2t ON “max”
- Time Current CurveI - Protection Device
RELT - Protection Device
- Time Current CurveHI - Protection Device
RELT - Protection Device
- Time Current Curve
- Band STDB 02- Band STDB 04- Band STDB 06- Band STDB 08- Band STDB 10- Band STDB 12- Band STDB 14- Band STDB 16
ST- Protection Device
I2t ON “max”
Green Iine = Full Clearing timeRed Line = Non Tripping time
Green Iine = Full Clearing timeRed Line = Non Tripping time
I protection set to 15×Ie (1) I protection set to 15×Ie (1)
Green Iine = Full Clearing timeRed Line = Non Tripping time
Green Iine = Full Clearing timeRed Line = Non Tripping time
10,00 100,00
1
0,1
0,01
0,001
1,00
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In10,00 100,00
1
0,1
0,01
0,001
1,00
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In
Time Current Curves (cold state)ST, I and Hi Protection Device
A.16Technical overview
Time Current Curves (cold state)HSIOC & GF Protection Device
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip Unit
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip Unit
- Time Current CurveHSIOC - Protection DeviceI - Present & ON
- Time Current CurveHSIOC - Protection DeviceI - NOT PESENY OR OFF ONI Setting On
sei at 15kA ST Ser at 12,5kASTDB 1
50 kA
100kA
85kA
65kA
50kA
65 kA
85 kA
100 kA
Green Iine = Full Clearing timeRed Line = Non Tripping time
Green Iine = Full Clearing timeRed Line = Non Tripping time
1
0,1
0,01
0,01
1000 10000 100000 10000,00
Trip
ping
Tim
e In
Sec
onds
(s)
Amps
1
0,1
0,01
0,01
1000 10000 100000 10000,00
Trip
ping
Tim
e In
Sec
onds
(s)
Amps
1,00 10,00
10
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In1,00 10,00
10
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In
GF set on breaker rating In
0,2 to 1 × In in steps of 0,01Setting Range
GF set on breaker rating In
0,2 to 1 × In in steps of 0,01Setting Range
- Time Current Curve
- Band GFDB 01- Band GFDB 03- Band GFDB 05- Band GFDB 07- Band GFDB 09- Band GFDB 11- Band GFDB 13
GF- Protection Device
I2t -OFF-
- Time Current Curve
- Band GFDB 02- Band GFDB 04- Band GFDB 06- Band GFDB 08- Band GFDB 10- Band GFDB 12- Band GFDB 14
GF- Protection Device
I2t -OFF-
1314 14
1212
1010
8
8
6
6
4
4
2
2
13
11
9
7
5
3
1
11
9
7
5
3
1
Green Iine = Full Clearing timeRed Line = Non Tripping time
Green Iine = Full Clearing timeRed Line = Non Tripping time
Time Current Curves
M-PACT
A.17 Technical overview
Time Current Curves (cold state)GF Protection Device
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip Unit
MPRO 27 & 50 Electronic Trip Unit MPRO 27 & 50 Electronic Trip Unit
1,00 10,00
10
1
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In
1,00 10,00
10
1
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In1,00 10,00
10
1
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In
1,00 10,00
10
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In
GF set on breaker rating In
0,2 to 1 × In in steps of 0,01Setting Range
GF set on breaker rating In
0,2 to 1 × In in steps of 0,01Setting Range
GF set on breaker rating In
0,2 to 1 × In in steps of 0,01Setting Range
- Time Current Curve
- Band GFDB 01- Band GFDB 03- Band GFDB 05- Band GFDB 07- Band GFDB 09- Band GFDB 11- Band GFDB 13
GF- Protection Device
I2t “low” -ON-
- Time Current Curve
- Band GFDB 02- Band GFDB 04- Band GFDB 06- Band GFDB 08- Band GFDB 10- Band GFDB 12- Band GFDB 14
GF- Protection Device
I2t “low” -ON-
13
1313
11
9
7
5
3
1
11
9
7
5
3
1
1414
1212
1010
8
6
4
2
8
6
4
2
14 14
12
10
8
6
4
2
12
10
8
6
4
2
11
9
7
5
3
1
13
11
9
7
5
3
1
Green Iine = Full Clearing timeRed Line = Non Tripping time
Green Iine = Full Clearing timeRed Line = Non Tripping time
Green Iine = Full Clearing timeRed Line = Non Tripping time
Green Iine = Full Clearing timeRed Line = Non Tripping time
- Time Current Curve
- Band GFDB 01- Band GFDB 03- Band GFDB 05- Band GFDB 07- Band GFDB 09- Band GFDB 11- Band GFDB 13
GF- Protection Device
I2t “med” -ON-
GF set on breaker rating Inv
0,2 to 1 × In in steps of 0,01Setting Range
- Time Current Curve
- Band GFDB 02- Band GFDB 04- Band GFDB 06- Band GFDB 08- Band GFDB 10- Band GFDB 12- Band GFDB 14
GF- Protection Device
I2t “med” -ON-
A.18Technical overview
Time Current Curves (cold state)GF Protection Device
MPRO 27 & 50 Electronic Trip Unit
1,00 10,00
MPRO 27 & 50 Electronic Trip Unit10
1
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In1,00 10,00
1
0,8
0,6
0,4
0,2
0,1
0,01
0,10
Trip
ping
Tim
e In
Sec
onds
(s)
x Breaker rating In
GF set on breaker rating In
0,2 to 1 × In in steps of 0,01Setting Range
GF set on breaker rating In
0,2 to 1 × In in steps of 0,01Setting Range
- Time Current Curve
- Band GFDB 01- Band GFDB 03- Band GFDB 05- Band GFDB 07- Band GFDB 09- Band GFDB 11- Band GFDB 13
GF- Protection Device
I2t “max” -ON-
- Time Current Curve
- Band GFDB 02- Band GFDB 04- Band GFDB 06- Band GFDB 08- Band GFDB 10- Band GFDB 12- Band GFDB 14
GF- Protection Device
I2t “max” -ON-
1313
11
9
7
5
3
1
11
9
7
5
3
1
14
12
10
8
6
4
4
6
8
10
12
14
2
2
Green Iine = Full Clearing timeRed Line = Non Tripping time
Green Iine = Full Clearing timeRed Line = Non Tripping time
Time Current Curves
M-PACT
A.19 Technical overview
M-PACT accessories Shunt trip
Undervoltage release
Auxiliary trip combination
Motorised spring charging unit
Circuit breaker closing coil
A wide range of optional accessories have been developed that are compatible with all M-PACT air circuit breakers, regardless of nominal rating or frame size. Each one incorporates 'easy-fit' design features for quick installation, either in the factory or by the user on site.
Energisation, locally or remote, will instantaneously activate the circuit breaker mechanism, ensuring rapid disconnection of the main contacts.
In addition, a series connected auxiliary switch ensures automatic isolation whenever the circuit breaker is open.
Shunt trip releases also have a wide operational voltage range, and they include the same easy-fit, clip-on/plug-in connectors as the closing coil above.
Instantaneously releases the circuit breaker trip mechanism should the supply voltage dip below the pre-set value.
Simple to install, these devices have the same easy-fit features as previously described.
Note: This is a 'no-volt/ no-close device. The circuit breaker cannot be closed (manually or electrically) unless the undervoltage release coil is energised.
Time delay undervoltage release similar to the above, but this electronic device prevents nuisance tripping of the circuit breaker if circuit interruption is not desirable when supply voltage drop is only transient. Fixed time delay 3 sec ±1sec.
The M-PACT circuit breaker can be equipped with the following auxiliary trips or releases 1 x Shunt trip + 1 x Closing coil + 1 x Undervoltage release or 1 time delay Undervoltage release.
The unique motor/gearbox unit is specially designed to operate with the full range of M-PACT breakers.
It is easily fitted with just two bolts. In the event of circuit breaker closure, this unit will automatically recharge the spring in readiness for instant reclosure should the need arise.
High speed recharging ensures that the springs are fully charged within approximately three seconds following a release.
As an optional feature, a "springs charged" contact is available for the motor unit.
The closing coil is an easy-to-fit, clip-on unit, with simple plug-in connectors. This permits either local or remote release of the spring charged closing mechanism by electrical operation.
An additional anti-pumping safety feature also ensures that the electrical closing signal must be released before further closure is attempted, and a cut-off is instigat-ed should a closing signal be maintained.
Because each coil operates within a wide voltage range, the number of individually rated coils required is drastically reduced.
A.20Technical overview
Auxiliary switches Cassette main terminal adaptors
Mechanical operation counter
Key interlock facility
The M-PACT circuit breaker is equipped with 5 NO and 3 NC auxiliary switches as standard. Maximum number of contacts is 8, for alternative configurations please contact for availability.
Combinations of rear and front access connections possible for entire range. Tested and approved from 50 to 80kA.
To simplify main busbar or cable termination, M-Pact provides a full range for rear and/or front access connection.
Bolt-on adaptor kits can be fitted easily to suit either horizontal or vertical connections.
Easily fitted, this useful accessory may be specified for use with either manual or motor charged M-PACT circuit breakers.
It is clearly visible through the front panel, and the counter provides an accurate record of the cumulative number of complete breaker closing operations.
Ready-to-fit interlocking device: Ronis, for installation betweenseparate circuit breakers, available in kit form.
This valuable safeguard ensures that a circuit breaker cannot be closed unless the dedicated key has been inserted and secured within the lock.
Lock and key types
Ronis: Type 1104B lock with standard key, 1/4" turn rotation to trap the key, compulsory spindle size.
M-PACT Accessories
M-PACT
A.21 Technical overview
Cable/busbar earthing device Cluster contacts
Carriage position switch
2/3 way cable mechanicalinterlocks
All 'M-PACT' circuit breakers can be fitted with an earthing device. It has a short circuit fault capacity equal to the Icw rating of the breaker. This permits either the feeder cables or the busbar to be safety held at earthed potential and locked during system maintenance operations.
These are the main isolating contacts which are fitted to the rear terminals on the moving portion of the withdrawable unit.
As part of standard inspection and maintenance procedures, cluster contacts have been designed to be easily and quickly removed and replaced using universal cluster pliers.
Available for fixed and withdrawable circuit breakers. These units enable the direct interlocking of M-PACT circuit breakers, either mounted side-by-side or stacked. The interlocking mechanisms are connected by a specially designed cable in '1 from 3' OR '2 from 3' configuration, and any mix of current ratings / pole configurations can be accommodated.
Standard cable lengths available: 1.6, 2.0, 3.0 metres. (Please contact our technical customer service department if longer length is required.)
Available as an optional device for mounting within the base of the cassette, this switch provides six single pole changeover contacts for local or remote electrical indication of the circuit breaker status: Connected, Test and Disconnected.
The Disconnected position is indicated only when minimum isolating distances between contacts on both the main and auxiliary circuits have been achieved.
This option is in addition to the mechanical indicators which are fitted as standard.
When installed, the carriage switch is IP2X protected and includes wiring to a terminal block located on the left-hand side of the cassette.
Note: The carriage position switch is an option only suitable for withdrawable circuit breakers.
A.22Technical overview
InterlocksMechanical interlocks can be fitted to the following electrical systems and can link 2 or 3 circuit breakers of anyrating or number of poles, Fixed or Withdrawable.
Typical circuit Interlock configuration Possible combinations
Type AInterlocking between 2 circuit breakers
B1 normal power supplyB2 generator (emergency) supply
B1 B20 0I 00 I
Circuit breaker B1 can only close if B2 is openCircuit breaker B2 can only close if B1 is open
Type BInterlocking between 3 circuit breakers
3 power supplies (generator ortransformers) feeding the samebusbar but parallel operation is prevented.
Available upon request.
B1 B2 B30 0 0I 0 00 I 00 0 I
Only 1 from 3 breakers can be closed
Type CInterlocking between 3 circuit breakers
2 bus sections can be powered by asingle transformer (bus couplerclosed) or by both transformers(bus coupler open).
Available upon request.
B1 B2 B30 0 0I 0 00 I 00 0 II 0 I0 I II I 0
Any 2 from 3 circuit breakers can be closedAny 1 from 3 circuit breakers can be closed
M-PACT Accessories
M-PACT
A.23 Technical overview
Circuit breaker insertion interlock Circuit breaker handling truck
Cassette interlock
Sealeddoor panelescutcheonAn optional IP54 complete front door panel is available should a higher degree of protection be necessary.
By incorporating this optional security interlock device into a system, it prevents the inadvertent insertion of an incorrectly rated withdrawable circuit breaker into a cassette.
Avai lable for withdrawable c ircuit breakers only, th is sophisticated interlock system secures the circuit breaker in thedisconnected position by means of a Ronis key.
When the key is removed, the safety shutters are automatically locked in position, thus preventing access to the contacts and also ensuring that the racking mechanism is not operable. For lock and key details refer to key interlock facility section (p. A.21)
Specifically designed for use with the M-PACT range, this dedicated handling truck is a useful accessory when faced with the task of inserting or removing the circuit breaker from its panel, or when transporting the unit should it be outside its cassette. Installers will also find it particularly valuable for top-tier mounted circuit breakers.
A.24Technical overview
Accessories Performance Data
DeviceOperating Voltage (V) Rating
(Amps resistive)AC DC Operating range
Auxiliary & carriage switch250 - 10
125 - 5250 - 0.25
Motor operator
220-250 220-250AC-50VADC-50W
110-130 110-130380-440 48, 60 0.85 to 1.1 times
24-30 rated voltage
Closing coil
220-250 220-250AC-300VADC-250W
110-130 110-130380-440 48 0.85 to 1.1 times
24-30 rated voltage
Shunt trip
220-250 220-250AC-300VADC-250W
110-130 110-130380-440 48 0.70 to 1.1 times
24-30 rated voltage
Instantanious Undervoltage release
380-440 110-130 -Inrush power consumption 300VAHolding power consumption 20VA
220-250 30-48 -110-130 -
Auxiliary power unit 110, 220, 380 110, 220 - -
Plug-in Portable Test Unit (PTU) Auxiliary Power Unit (APU)
Specially designed for reliable testing of the MCR and HSISCprotection systems on each phase, by means of tertiaryinjection. The test unit is also used to prove both overcurrentand earth fault pick-up levels. Can also be employedto test for tripping in order to verify efficient microprocessoroperation. The test unit incorporates a set of rechargeablebatteries and includes a charger unit as standard.
Available to be fitted within the circuit breaker cubicle, anAPU ensures that M-PRO receives independent and continuous power at all times. The APU accepts any input supply voltage within 380VAC, 110V, 220V AC/DC. Maximuminput current is 0.5 A. 1m length cable (twisted pair) shouldbe used to connect auxiliary supply and MPRO protectionrelay.
M-PACT Accessories
M-PACTAir Circuit Breaker 400-4000A
BMpro 27 & 50 Connection ....................................................................................................................................................................B.2
Dimensional Drawings ...........................................................................................................................................................................B.6
Wiring DiagramsDimensional Drawings
B.2 Wiring Diagrams - Dimensional Drawings
M-PACT
Connection scheme
N-RC
A15 A14
N-RC- +
N
B 5 B 6
24V+ 24V-
+24-VDC
Electronic Trip Unit MPRO 27
Connection scheme
Relay O/P2
A 6 A 5
Relay O/P1
A 8 A 7
Electronic Trip Unit MPRO 50
N-RC
A15 A14
N-RC- +
N
Relay O/P3 Relay O/P4
A 2 A 1A 4 A 3 B 5 B 6
24V+ 24V-
+24-VDC
EL CT
B 3 B 4
Interposing CT
A12 A11 A10 A 9
1 2 3 4
Input 1 - 4
A13
C
A20 A19
RX- RX+
Communication
A16
SCR
A18 A17
TX- TX+
N
Breaker accessories
OFF ONOFF
C15
AAAAABBBAA
C
D
MLAL
M ST CC UVRUVTD
C13
C11
C9C7C5C3C1
B15
B13
(+VE)(-VE)
B11
C16
C14
C12
C10
LP6
LP5
LP7
C8C6C4C2
B16
B14
(-VE)
B12
B10
B8
LP4
B9B7
(+VE)
B1B2
Mpro 27 & 50 Connection Scheme
Wiring Diagrams
B.3Wiring Diagrams - Dimensional Drawings
Dimensional DrawingsHorizontal, rear access connectionFixed patternType A-3 pole- Frame size 1, In=400A to 1600A
Type A-4 pole- Frame size 1, In=400A to 1600A
100 to door
100
Centre line of operating panel
Centre line of operating panel
Centre line ofoperating panel
Centre line ofoperating panel
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Minimum space to earth metaland for arc chute removal
Minimum space to earth metaland for arc chute removal
Insulated metal or insulatedsheet ( customer supplied )
Insulated metal or insulatedsheet ( customer supplied )
Dimensional Drawings
B.4 Wiring Diagrams - Dimensional Drawings
M-PACT
Horizontal, rear access connectionFixed patternType D-3 pole- Frame size 1, In=400A to 1600A
100 to door
100 to door
Centre line of operating panel
Centre line of operating panel
Centre line ofoperating panel
Centre line ofoperating panel
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Minimum space to earth metaland for arc chute removal
Minimum space to earth metaland for arc chute removal
Insulated metal or insulatedsheet ( customer supplied )
Insulated metal or insulatedsheet ( customer supplied )
Type D-4 pole- Frame size 1, In=400A to 1600A
B.5Wiring Diagrams - Dimensional Drawings
100 to door
100 to door
Horizontal, rear access connectionFixed patternType A, D-3 pole- Frame size 1, In=2000A to 2500A
Centre line of operating panel
Centre line of operating panel
Centre line ofoperating panel
Centre line ofoperating panel
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Minimum space to earth metaland for arc chute removal
Minimum space to earth metaland for arc chute removal
Insulated metal or insulatedsheet ( customer supplied )
Insulated metal or insulatedsheet ( customer supplied )
Type A, D-4 pole- Frame size 1, In=2000A to 2500A
Dimensional Drawings
B.6 Wiring Diagrams - Dimensional Drawings
M-PACT
Horizontal, rear access connectionFixed patternType A, D-3 pole- Frame size 2, In=3200A to 4000AType H-3 pole- Frame size 2, In=800A to 4000A
100 to door
100 to door
Centre line of operating panel
Centre line of operating panel
Centre line ofoperating panel
Centre line ofoperating panel
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Minimum space to earth metaland for arc chute removal
Minimum space to earth metaland for arc chute removal
Insulated metal or insulatedsheet ( customer supplied )
Insulated metal or insulatedsheet ( customer supplied )
Type A, D-4 pole- Frame size 2, In=3200A to 4000AType H-4 pole- Frame size 2, In=800A to 4000A
B.7Wiring Diagrams - Dimensional Drawings
Rear access connectionWithdrawable patternType A-3 pole- Frame size 1, In=400A to 1600A
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Centre line of operating panel
Centre line of operating panel
35 Test50 Disconnected
275 Fully withdrawn
Connected
Ventilation
Minimum clearanceto cassette side
Centre line of operating panel
Centre line of operating panel
35 Test50 Disconnected
275 Fully withdrawn
Connected
Ventilation
Minimum clearanceto cassette side
to door
to door
Type A-4 pole- Frame size 1, In=400A to 1600A
Dimensional Drawings
B.8 Wiring Diagrams - Dimensional Drawings
M-PACT
Rear access connectionWithdrawable patternType A-3 pole- Frame size 1, In=2000A & 2500AType D-3 pole- Frame size 1, In=400A to 2500A
Type A-4 pole- Frame size 1, In=2000A & 2500AType D-4 pole- Frame size 1, In=400A to 2500A
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Centre line of operating panel
Centre line of operating panel
35 Test
50 Disconnected
275 Fully withdrawn
Connected
Ventilation
Minimum clearanceto cassette side
Centre line of operating panel
Centre line of operating panel
35 Test
50 Disconnected275 Fully withdrawn
Connected
Ventilation
Minimum clearanceto cassette side
to door
to door
B.9Wiring Diagrams - Dimensional Drawings
Rear access connectionWithdrawable patternType A, D-3 pole- Frame size 2, In=3200AType H-3 pole- Frame size 2, In=800A to 3200A
Type A, D-4 pole- Frame size 2, In=3200AType H-4 pole- Frame size 2, In=800A to 3200A
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
to door
to door
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
50 Disconnected35 Test
275 Fully withdrawn
50 Disconnected35 Test
275 Fully withdrawn
Connected
Connected
Vent
ilatio
nVentilation
Minimum clearance to cassette side
Minimum clearance to cassette side
Dimensional Drawings
B.10 Wiring Diagrams - Dimensional Drawings
M-PACT
Rear access connectionWithdrawable pattern
Type A, D,H-3 pole - Frame size 2, ln=4000A
Type A, D,H-4 pole - Frame size 2, ln=4000A
Must not be removedor fitted horizontally
Must not be removedor fitted horizontally
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel 50 Disconnected
35 Test
275 Fully withdrawn
50 Disconnected35 Test
275 Fully withdrawn
Connected
Connected
to d
oor
to d
oor Ventilation
Vent
ilatio
n
Minimum clearance to cassette side
Minimum clearance to cassette side
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
B.11Wiring Diagrams - Dimensional Drawings
Front access connectionFixed pattern
Type A, D-3 pole - Frame size 1, ln = 400A to 1600A
Type A, D-4 pole - Frame size 1, ln = 400A to 1600A
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Insulated metalor insulated sheet(customer supplied)
Insulated metalor insulated sheet(customer supplied)
Minimum space to earth metaland for arc chute removal
Minimum space to earth metaland for arc chute removal
100 to door
100 to door
Minimum clearance to breaker side
Minimum clearance to breaker side
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Dimensional Drawings
B.12 Wiring Diagrams - Dimensional Drawings
M-PACT
Front access connectionFixed pattern
Type A, D-3 pole - Frame size 1, ln = 2000A to 2500A
Insulated metalor insulated sheet(customer supplied)
Minimum space to earth metaland for arc chute removal
100 to door
Insulated metalor insulated sheet(customer supplied)
Minimum space to earth metaland for arc chute removal
100 to door
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Minimum clearance to breaker side
Minimum clearance to breaker side
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Type A, D-4 pole - Frame size 1, ln = 2000A to 2500A
B.13Wiring Diagrams - Dimensional Drawings
Front access connectionFixed pattern
Type A, D-3 pole - Frame size 2, ln = 3200A to 4000AType H-3 pole - Frame size 2, ln = 800A to 4000A
Insulated metalor insulated sheet(customer supplied)
Minimum space to earth metaland for arc chute removal
100 to door
Insulated metalor insulated sheet(customer supplied)
Minimum space to earth metaland for arc chute removal
100 to door
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Minimum clearance to breaker side
Minimum clearance to breaker side
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Front Access Connection
Type A, D-4 pole - Frame size 2, ln = 3200A to 4000AType H-4 pole - Frame size 2, ln = 800A to 4000A
B.14 Wiring Diagrams - Dimensional Drawings
M-PACT
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Minimum clearance to cassette side
Minimum clearance to cassette side
Connected
Connected
Disconnected
Disconnected
Test
Test
to d
oor
to d
oor
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Front access connectionWithdrawable pattern
Type A, D-3 pole - Frame size 1, ln = 400A to 1600A
Type A, D-4 pole - Frame size 1, ln = 400A to 1600A
B.15Wiring Diagrams - Dimensional Drawings
Front access connectionWithdrawable pattern
Type A, D-3 pole - Frame size 1, ln = 2000A to 2500A
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Minimum clearance to cassette side
Minimum clearance to cassette side
Connected
Connected
Disconnected
Disconnected
Test
Test
to d
oor
to d
oor
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Front Access Connection
Type A, D-4 pole - Frame size 1, ln = 2000A to 2500A
B.16 Wiring Diagrams - Dimensional Drawings
M-PACT
Front access connectionFixed pattern
Type A, D-3 pole - Frame size 2, ln = 3200A to 4000AType H-3 pole - Frame size 2, ln = 800A to 4000A
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Center line ofoperating panel
Minimum clearance to cassette side
Minimum clearance to cassette side
Connected
Connected
DisconnectedTest
DisconnectedTest
to d
oor
to d
oor
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Copperwork must be supported within 200 mm of breakerconnections-busbars or cables. All connections to be tightened to 50Nm.
Type A, D-4 pole - Frame size 2, ln = 3200A to 4000AType H-4 pole - Frame size 2, ln = 800A to 4000A
B.17Wiring Diagrams - Dimensional Drawings
Adaptor connections
Rear Adapter Vertical ConnectionType A - Frame 1 - ln = 400A to 1600A (max)
Rear Adapter Horizontal ConnectionType A - Frame 1 - ln = 400A to 1600A (max)
Type D - Frame 1 - ln = 400A to 2500A (max)
Rear Adapter Vertical / Horizontal Connection
Type A,D,H - Frame 2 - ln = 800A to3200A (max)
Front Access Connection
B.18 Wiring Diagrams - Dimensional Drawings
M-PACT
Type A - Frame 1 - ln = 400A to 2500A (max)Type D - Frame 1 - ln = 400A to 2500A (max)
Type A,D - Frame 2 - ln = 3200A to 4000A (max)Type H - Frame 2 - ln = 800A to 4000A (max)
Type A,D,H - Frame 2 - ln = 4000A
Copper connections - Rear access (withdrawable)
IP54 Door (Withdrawable unit only - Frame 1&2 only)
Copper connections - Front access (Fixed and/or withdrawable)
B.19Wiring Diagrams - Dimensional Drawings
Type A,D - Frame 2 - ln = 3200A to 4000A (max)Type H - Frame 2 - ln = 800A to 4000A (max)
A. recommend installtion mounting cut
Cassette mounting details
Type A,D - Frame 1 - ln = 400A to 2500A (max)
Terminals
Terminals
Ventilation in base of cassette(leave unobstructed)
Ventilation in base of cassette(leave unobstructed)
Centre line ofoperating panel
Centre line ofoperating panel
3 pole
3 pole 4 pole
4 pole3 pole
4 pole
4 pole
4 pole
3 pole
3 pole
AA
A
A
A A
A
A
Adaptor Connection
B.20 Wiring Diagrams - Dimensional Drawings
M-PACT
Door cut-outs
Fixed pattern - Facia cut-out
Withdrawable pattern - Cubicle door/panel
Frame 1 = 42.5Frame 2 = 102.5
The cut-out dimensions shown above givean approximate nominal clearance of 30mm aroundACB fascia. These sizes are for guidanceand can be scaled if different apertureis required.
Escutcheon(LLA11PD055)
Escutcheon seal(LLA11RS001)
ACB facia16 off 3.0 6Self tapping screws
Frame 1 - Up to 2500A max.= 40Frame 2 - Up to 4000A max.= 100
Datum for 16 off 4 holes in door / panel - bottom left hand comer of cassette viewed from front.
B.21Wiring Diagrams - Dimensional Drawings
2-Way cable interlocking
Fixed pattern - Front/rear access
Withdrawable pattern - Front/rear access
Min.clearancebelowcassette
Min.clearancebelowcassette
Min.bend radius 120
Min.bend radius 120 Min.bend radius 120
Min.bend radius 120
900
Max
ver
tical
bas
e to
bas
e90
0 M
ax v
ertic
al b
ase
to b
ase
Frame 1-3P = 322Frame 1-4P = 422Frame 2-3P = 410Frame 2-4P = 540
Frame 1-3P = 329Frame 1-4P = 429Frame 2-3P = 419Frame 2-4P = 549
Door Cut-outs