GE NEMA Rated Full Voltage Starters CR306 Nonreversing Magnetic Motor Starters GE Fastrac™ Program items are printed in red type. CR306 Single-Phase, Two-Pole Forms, NEMA Types Open, 1, 3R, 12 and 4/4X, 60 Hertz® 25 Horsepower Maximum NEMA Sizes 00-3 600 Volts Maximum 50/60 Hertz Single-phase List price includes a holding interlock. One heater (per starter) for sizes 00-2 and two heaters (per starter) for size 3 should be ordered as separate items. List Price $9.00 each, GO-10H. Packaged in quantities of three; must be ordered in multiples of three. Select heaters by using tables on pages 1-71 to 1-75. NEMA Size 00 0 1 1P 2 3 Continuous Ampere Rating 9 18 27 36 45 90 Maximum Horsepower© Voltage (60 Hertz) 115-120 230-240 115-120 230-240 115-120 230-240 115-120 230-240 115-120 230-240 115-120 230-240 460-480 575-600 Horse- power VS 1 1 2 2 3 3 5 3 7'/> 7V4 15 25 25 Open Type Catalog Number CR306 •-1002 H003 J002 J003 K002 K003 K002BMA K003BMA 1-002 L003 M002 M003 M004 MOOS List Price, GO-10G $162.00 162.00 183.00 183.00 213.00 213.00 279.00 279.00 387.00 387.00 642.00 642.00 642.00 642.00 NEMA Type 1 General-Purpose Catalog Number CR306 H 1 0^ H103 J102 J103 K102 K103 K102BKA K103BKA L102 L103 M102 M103 M104 M105 List Price, GO-10G $174.00 174.00 195.00 195.00 225.00 225.00 291.00 291.00 447.00 447.00 762.00 762.00 762.00 762.00 NEMA Type 3R Rainproof Sleet-Resistant Catalog Number CR306 List Price, GO-10G Use NEMA Size 0 J60.-: J603 K602 K603 K602BKA K603BKA L602 L603 M602 M603 M604 M605 $267.00 267.00 297.00 297.00 363.00 363.00 579.00 579.00 918.00 918.00 918.00 918.00 NEMA Type 129 9 Dust-tight. Driptight Industrial Use Catalog Number CR306 List Price, GO-10G Use NEMA Size 0 :!SS K^L^ K203 K202BKA K203BKA ! v .' ; 'i~ $267.00 267.00 297.00 297.00 363.00 363.00 579.00 579.00 918.00 918.00 918.00 918.00 NEMA Type 4/4X Wateitight, Dust-Tight (Stainless Steel) a Catalog Number CR306 List Price, GO-10G Use NEMA Size 0 J4'V K402 K40J KJ02BKA K4CJ'-.KA M4J4 M405 $ 405.00 405.00 441.00 441.00 507.00 507.00 879.00 879.00 1374.00 1374.00 1374.00 1374.00 © Pricing for 50-Hertz forms (at standard voltages) is the same as shown in table for 60 Hertz. Listed prices for 460-480 Volt also apply to 380-415 Volt, 50 Hertz. See page 1-2 for 380-415 Volt horsepower ratings. © Motor full-load current should not exceed continuous Ampere rating of starter. NEMA Types 4/4X and 12 starters are UL listed to include Class II Groups F and G, Division 2 only, and Class III hazardous locations. External reset not included on standard forms. References: Instructions NEMA Size 00-1 2 3 4 5 6 7-9 Publication Number GEH-5190 GEH-4774 GEH-4806 GEH-4807 GEH-4839 GEH-5198 GEH-5108 Factory-Installed Modifications.......... pages 1-50to 1-56 Field-Installed Modification Kits ....... pages 1-57 to 1-61 Heater Selection Tables ................ pages 1-71 to 1-75 Prices and data subject to change without notice 1999 Issue 1-7

Upload: others

Post on 05-Feb-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

  • GE NEMA Rated Full Voltage Starters

    CR306 Nonreversing Magnetic Motor Starters

    GE Fastrac™ Program items are printed in red type.

    CR306 Single-Phase, Two-Pole Forms,NEMA Types Open, 1, 3R, 12 and 4/4X, 60 Hertz®

    25 Horsepower MaximumNEMA Sizes 00-3

    600 Volts Maximum50/60 Hertz

    Single-phase

    List price includes a holding interlock. One heater (per starter) forsizes 00-2 and two heaters (per starter) for size 3 should beordered as separate items. List Price $9.00 each, GO-10H.

    Packaged in quantities of three; must be ordered in multiples ofthree. Select heaters by using tables on pages 1-71 to 1-75.

    NEMASize

    00

    0

    1

    1P

    2

    3

    ContinuousAmpereRating

    9

    18

    27

    36

    45

    90

    MaximumHorsepower©

    Voltage(60 Hertz)

    1 1 5 - 1 2 0230-240

    1 1 5 - 1 2 0230-240

    115 -120230-240

    115-120230-240

    115 -120230-240

    115-120230-240460-480575-600

    Horse-power

    VS1

    12

    23

    35

    37'/>

    7V4152525

    Open Type

    CatalogNumberCR306

    •-1002H003

    J002J003

    K002K003

    K002BMAK003BMA

    1-002L003

    M002M003M004MOOS

    ListPrice,

    GO-10G

    $162.00162.00

    183.00183.00

    213.00213.00

    279.00279.00

    387.00387.00

    642.00642.00642.00642.00

    NEMA Type 1General-Purpose

    CatalogNumberCR306

    H 1 0^H103

    J102J103

    K102K103

    K102BKAK103BKA

    L102L103

    M102M103M104M105

    ListPrice,

    GO-10G

    $174.00174.00

    195.00195.00

    225.00225.00

    291.00291.00

    447.00447.00

    762.00762.00762.00762.00

    NEMA Type 3RRainproof

    Sleet-Resistant

    CatalogNumberCR306

    ListPrice,

    GO-10G

    Use NEMA Size 0

    J60.-:J603

    K602K603

    K602BKAK603BKA

    L602L603

    M602M603M604M605

    $267.00267.00

    297.00297.00

    363.00363.00

    579.00579.00

    918.00918.00918.00918.00

    NEMA Type 129 9Dust-tight. Driptight

    Industrial Use

    CatalogNumberCR306

    ListPrice,

    GO-10G

    Use NEMA Size 0

    :!SSK^L^K203

    K202BKAK203BKA

    !v.';'i~

    $267.00267.00

    297.00297.00

    363.00363.00

    579.00579.00

    918.00918.00918.00918.00

    NEMA Type 4/4XWateitight, Dust-Tight

    (Stainless Steel) a

    CatalogNumberCR306

    ListPrice,

    GO-10G

    Use NEMA Size 0

    J4'V

    K402K40J

    KJ02BKAK4CJ'- .KA

    M4J4M405

    $ 405.00405.00

    441.00441.00

    507.00507.00

    879.00879.00

    1374.001374.001374.001374.00

    © Pricing for 50-Hertz forms (at standard voltages) is the same as shownin table for 60 Hertz. Listed prices for 460-480 Volt also apply to380-415 Volt, 50 Hertz. See page 1-2 for 380-415 Volt horsepowerratings.

    © Motor full-load current should not exceed continuous Ampere rating ofstarter.

    NEMA Types 4/4X and 12 starters are UL listed to include Class IIGroups F and G, Division 2 only, and Class III hazardous locations.External reset not included on standard forms.

    References:Instructions

    NEMA Size

    00-123456

    7-9

    Publication Number

    GEH-5190GEH-4774GEH-4806GEH-4807GEH-4839GEH-5198GEH-5108

    Factory-InstalledModifications.......... pages 1-50 to 1-56

    Field-InstalledModification Kits....... pages 1-57 to 1-61

    Heater SelectionTables . . . . . . . . . . . . . . . . pages 1-71 to 1-75

    Prices and data subject to change without notice 1999 Issue 1-7

  • GE NEMA Rated Full Voltage Starters

    Section 7

    GE Fastrac™ Program Service

    Full Voltage Noncombination StartersGE Fastrac Program covers nonreversing magnetic motor starters(3-phase, 3-pole) in NEMA sizes 0-4 with a full range of options. Italso includes standard catalog torms of many other nonreversingmagnetic motor starters, magnetic reversing controllers, magnetictwo-speed controllers and magnetic contactors.

    Combination StartersEighty percent of all the combination starters that GE sells areavailable on a GE Fastrac Program basis.

    Standard cycle: 2 weeksGE Fastrac Program: 1 day

    To order GE Fastrac starters, select and price items required thatare printed with red catalog numbers. Clearly indicate on the orderthat Fastrac service is required.

    Refer? nces:DEP-C15 Fastrac Application & Selection Guide for NEMA ControlsDEP-078 Fastrac Now™—the motor starter you need is onlyminutes away.

    FASTRAC

    Take Control With GE

    Fastrac Now™Distributor-assembled kits for various enclosed startercombinations. No point-to-point wiring required. Assemblypossible by anyone while retaining full UL listing. See pages 1-78to 1-84 for Fastrac Now™ distributor-assembled starters.

    GE's 300-Line of NEMA rated controls has a complete offering offull voltage nonreversing, reversing, two-speed and combinationmotor starters, plus magnetic contactors.

    They are available in NEMA Sizes 00-9; 600 Volts maximum, 1600horsepower maximum. Open forms are available in sizes 00-9.Type 1 enclosures are available in sizes 00-6. Types 3R, 12, 4, and4X enclosures are available in sizes 0-6. The 300-Line hasstandard specification approval by many major manufacturers forthe toughest industrial applications.

    Nonreversing Magnetic Motor Starters(CR306, CR386 Series) . . . . . . . . . . . .1-4 to 1-11

    Magnetic Reversing Controllers(CR309 S e r i e s ) . . . . . . . . . . . . . .1-12to1-17

    Magnetic Two-Speed C o n t r o l l e r s . . . . . . . . . . . . . . . . . . . . . . . . . . 1 -18 to 1-23Nonreversing Combination Magnetic Starters

    (CR307, CR308, CR310, CR311, CR387,CR390, CR385 Series) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24 to 1-38

    Combination Magnetic Safety Starters(CR307, CR308, CR310, CR311 Series). . . . . . . . . . . . . . . . . . .1-39 to 1-41

    Magnetic Contactors(CR305, CR385 S e r i e s ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 -42 to1 -49

    1-2,1-3Supplementary Information For All Full Voltage Starters:

    technical D a t a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Factory-Installed Modifications AndModification K i t s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Motor Current Ratings . . . . . . . . . . . . . . . . . . . . . . . . . .Heater Selection Tables . . . . . . . . . . . . . . . . . . . . . . . . .

    .1-50 to 1-61..1-69,1-70.1-71(01-75

    Solid-State Overload R e l a y s . . . . . . . . . . . . . . . . . .1-62to1-64Starter Select ion. . . . . . . 1-65Panel Mount Overload Relays . . . . . . . . . . . . . . . .1-66 to 1-68NEMA Type Enclosures Only . .1 -76 ,1 -77Fastrac Now Distributor-Assembled S t a r t e r s . . . . . . . . . . . . . . . . 1-78 to 1-84

    References:See Publication Index, Section 18.

    Data subject to change without notice 1999 Issue 1-1

  • GE NEMA Rated Full Voltage Starters

    300-LineApplication Information and Technical Data

    Normal Starting Duty HP Rating®Single Phase

    115V60H2230V 60Hz

    Three Phase200V 60Hz230V 60Hz380-41 5V 50Hz460V 60Hz575V 60Hz

    Plugging or Jogging HP Rating©SinglePhase

    115V60Hz230V 60Hz

    Three Phase200V 60Hz230V 60Hz380-415V50HZ460V 60Hz575V 60Hz

    Continuous Current MaxStarters and EnclosedContactors

    Open Contactors

    Coil Burden (VA)Inrush 2-PoleHolding 2-PoleInrush 3-PoleHolding 3-PoleInrush 4- and 5-PoteHolding 4- and 5-Pole

    Control Power TransformerVA (Min)

    Coil Operating Voltage% Minimum Pickup% Maximum Dropout

    Switching Delay 3-PolePickup Typical (Milliseconds)Dropout Typical (Milliseconds)

    Mechanical Lite Millions Nominal

    Weight (Less Carton)Contactor (Pounds)Starter (Pounds)

    Power TerminalsWire Size Range

    (75 DEG) AWGTorque (Pounds-Inches)

    Max. Noise (DBA)

    NEMA Size

    00

    1/31

    VA1 V 4Vh22

    NANA

    NANANANANA

    910

    15124

    15124

    15124

    50

    8563

    15-307-15

    20

    23A3%

    14-820

    50

    0

    12

    33

    " 555

    1^1

    Vk1'/2

    1Vz22

    1 820

    15124

    15124

    15124

    50

    8563

    15-307-15

    20

    2%33/4

    14-820

    50

    1

    23

    7V47V4101010

    12

    33555

    2730

    15124

    15124

    15124

    50

    8563

    15-307-15

    20

    2%3V,

    14-820

    50

    2

    3714

    101 5252525

    25

    Th10151 515

    4550

    52860

    52860

    57675

    100

    8568

    20-407-15

    10

    61/27%

    14-450

    50

    3

    7%15

    2530505050

    510

    1 520303030

    90100

    115283

    115283

    124887

    200

    8565

    20-457-15

    5

    1 517%

    10-1/0150

    50

    4

    NANA

    405075100100

    NANA

    2530506060

    135150

    124887

    124887

    135695

    250

    8565

    20-457-15

    5

    14%17V4

    8-3/0200

    50

    5

    NANA

    75100150200200

    NANA

    6075

    125150150

    270300

    2580191

    2580191

    3600276

    500®

    8565

    30-5015-25

    5

    4853

    1/0-500kcmil300

    65

    6

    NANA

    150200300400400

    NANA

    125150250250250

    540600

    3360255

    3360255NANA

    500®

    8565

    30-5015-25

    1

    4875

    2 2/0-500kcmil375

    65

    7

    NANA

    300500600600

    NANA

    NANANANANA

    810900

    1600210

    1600210NANA

    1000®

    8550

    60-90100-150

    1

    79106

    3 2-600kcmil500

    65

    8

    NANA

    450750900900

    NANA

    NANANANANA

    1 2 1 51350

    1500140

    2900300NANA

    1500®

    8550

    80-12525-100

    1

    203263

    4 2-600kcmil500

    65

    9

    NANA

    800135016001600

    NANA

    NANANANANA

    22502500

    2900300

    3600400NANA

    1501®

    8550

    80-12525-100

    0.5

    302365

    NANA

    65

    © When operation of the controller requires jogging (inching) or plug stopping or when normal operation requires continued operation in excess of 5operations per minute or 10 operations in a 10-minute period, the plugging or jogging horsepower ratings must be followed.

    ® In lieu of a 500 to 1500 VA control transformer, a 50 VA unit in conjunction with a control relay can be used as follows:1. Wire control relay coil in control circuit on secondary side of control transformer.2. Wire two poles of control relay in series with contactor coil at line voltage.

    Mounting PositionDevices must be mounted to a sturdy vertical surface with the lineside terminals up. No other orientations are permitted.

    Operating TemperatureEquipment is designed for ambient temperature outside ofequipment enclosures to be -25° to 40°C. When contactor isenergized, temperatures will be above outside ambient inequipment enclosures. Temperature rises inside the enclosuresshould be limited so that internal air temperature does not exceed65° for sizes 00 to 6 and 60°C for sizes 7 to 9. If condensingmoisture is present, space heater kits should be used to preventcondensation when contactor is not energized.

    Storage temperature should be -30° to 65°C. If equipment isstored over 1 week, it may be necessary to cover the equipmentand provide a source of heat to prevent condensation.

    1-2 1999 Issue Data subject to change without notice

  • GE NEMA Rated Full Voltage Starters

    Short-Circuit RatingsFusible forms of combination magnetic starters equipped with ULlabeled, nonrenewable, NEC-type fuses listed in the table below,are adequate for installation on motor branch circuits where theavailable short-circuit current at the incoming line terminals of thestarter does not exceed the value shown.Circuit breaker-type combination magnetic starters equipped withthe circuit breakers listed in the table at right are adequate forinstallation on motor branch circuits where the available short-circuit current at the incoming line terminals of the starter does notexceed the value shown.For either type, it is recognized that maintenance of somecomponents may be required after a branch circuit fault and insome cases a device may require replacement.Fusible Combination Starters

    NEMASize

    0-34,5

    0-5

    6

    Fuse Type

    H, KH, K

    J, RK-1.RK-5

    J, L, RK-1.RK-5

    Maximum Symmetrical rms Amperes

    5,00010,000

    100,000

    100,000

    Circuit Breaker Combination StartersBreaker

    Type

    TEB

    TEC®

    TEC®

    TED

    THED

    TFJ&TFK

    THFK

    TJJ&TJK

    THJK

    TKM, TKCTHKM8

    TB6, TBC

    RatingAmperes

    15-5015-7015-10025-150

    3-303-50

    15-5030-10050-150

    3-303-50

    15-5030-10050-150

    15-5015-30 i35-70 /15-50 -i60-100 /25-100 -,

    110 -150 /

    15-5015-50 T60-70 115-50 -i60-100 I25-100 -i

    110 -150 1

    70-225

    70-225

    225-600

    225-400 -i450-600 /

    300-800300-800300-800

    NEMASize

    0123

    01234

    01234®

    01

    2

    3

    01

    2

    3

    4

    4

    5

    5

    6

    Maximum Symmetrical rms Amperes

    240 Volt

    5,0005,0005,0005,000

    25,00025,00025,00025,00025,000

    100,000100,000100,000100,000100,000

    5,000r 25,000i 5,000r 25,0001 5,000r 25,000i 5,000

    65,000r 65,0001 65,000r 65,000i 65,000r 65,000i 42,000

    22,000

    25,000

    10,000

    r 35,000t 10,000

    42,00065,00065,000

    480 Volt

    ~

    25,00025,00025,00025,00025,000

    100,000100,000100,000100,000100,000

    5,00025,000

    5,00025,0005,000

    25,0005,000

    14,00025,00014,00025,00025,00025,00025,000

    22,000

    25,000

    10,000

    35,00010,000

    30,00035,00065,000

    600 Volt

    -

    5,0005,0005,0005,0005,000

    100,000100,000100,000100,000100,000

    5,0005,0005,0005,0005,0005,0005,000

    5,00025,000

    5,00025,0005,000

    25,0005,000

    22,000

    10,000

    10,000

    25,00010,000

    22,00025,00042,000

    © Open continuous Ampere ratings are for contactors only.© Mag-Break® motor circuit protector with adjustable magnetic trip

    (Amperes).® Mag-Break motor circuit protector with adjustable magnetic trip

    (Amperes) and current limiter.® 100 Amperes and smaller current limiters are UL listed.

    300-Line\Application Information and Technical Data \

    Control TransformersWhere to UseIt is often desirable to use a control transformer in conjunction witha magnetic starter or controller to provide low voltage control.

    Description—Factory WiredA transformer, with sufficient capacity for the control circuit,mounted with the starter can be supplied by the factory for themajority of transformer ratings and types of enclosures.

    Coil Suffix(THIS TABLE IS TO BE USED FOR STARTER FORMS WITHOUTCONTROL TRANSFORMERS.)Indicates voltage and frequency of operating coils. For use inordering full voltage starters and contactors, Sizes 00-6, with othercoil ratings than those shown in listing on pages 1-6 to 1-49.Frequency(Hertz)

    60Frequency(Hertz)

    50

    24V24

    -

    -

    11 5-1 20V®02

    ' 110V

    02

    200-208V®23

    --

    230-240V®03220V

    03

    265-277V

    13

    380-41 5V

    64

    460-480V®04

    440V

    04

    575-600V®05

    550V

    05

    Note: The 02 coil suffix (115-120V, 60 Hz/110V, 50 Hz) supersedes the 22coil suffix (120V, 60 Hz).© Suffix shown for this voltage is part of Catalog Number in magnetic

    starter-contactor listings.

    Auxiliary Contact RatingsNEMA Size 0-9

    AC Volts

    s 115230460575

    Amperes

    Continuous

    10101010

    Make

    60301 512

    Break

    6.03.01.51.2

    DC Volts

    125250

    1 010

    .— 1 . 10,5

    Contactor DC Ratings

    NEMASize

    00

    0

    1 .

    2

    3

    4

    No. ofPoles inSeries

    1234

    1234

    1234

    234

    234

    234

    ContinuousCurrentRating

    9999

    181 81 818

    27272727

    454545

    909090

    135135135

    Interrupting Ratings

    Inductive Amps

    125 Volts

    N.O. N.C.

    2.5 2.57 714 1425 25

    2.8 2.57 714 1425 25

    3 2.57 714 1425 25

    71425

    71425

    71425

    250 Volts

    N.O. N.C,

    0,6 0.51.2 1.23.5 3.57 7 '

    0.7 0.51.5 1 .23.5 3.57 7

    0,7 0.51.5 1.23.5 3.57 7

    1.53.57

    2.24.59

    2.24.59

    Noninductive Amps

    125 Volts

    N.O. N.C.

    5 425 2535 3550 • 50

    6 4.535 2550 3590 60

    6.5 4.550 2570 35120 60

    60120160

    • 600600600

    600600600

    250 Volts

    N.O, N.C.

    1 0.85 415 1550 50

    1.1 0.96 4.525 2560 55

    1 .2 0.97 4.535 2570 55

    94080

    300600600

    300600600

    Data subject to change without notice 1999 Issue 1-3

  • GE NEMA Rated Full Voltage Starters

    CH306, CR386 Nonreversing Magnetic Motor Starters1600 Horsepower MaximumNEMA Sizes 00-9600 Volts Maximum50/60 Hertz Basic 300-Line Features

    CONTACTOR

    Captive saddle clamps

    Staggered terminals(optional above size 1)

    Encapsulated coil

    Coil retainers

    Armature retaining clip

    Long-life armature

    OVERLOAD RELAY

    Manual Weld Check

    ±10% trip adjustment

    Overload relay heaters,(not shown)

    Visual trip indicator

    Manual reset arm

    Captive saddle clamps

    Typical Size 1 Motor StarterGE's full voltage (600-Volt maximum) magnetic motor starter hasan encapsulated coil and a 3-leg overload relay to protect againstoverloads in all phases. It is on standard specifications of majormanufacturers. The line offers features and benefits most askedfor by users.Forms available include reversing and nonreversing, two-speed,and combination, sizes 00-9.• Toolless contactor disassembly (Sizes 00-4)—allows

    quick access for inspection and maintenance. Just release tworetainers and pull a clip to get at magnet, coil, and contacts.

    • Saddle clamp terminals (Sizes 00-1)—accommodate ring,spade, and stripped wire leads and carry permanent stamped-in identification. Staggered arrangement makes wiring easierand helps prevent shorting between phases.

    • Current-carrying components—contact tips are weld-resistant silver cadmium oxide (fine silver on sizes 00 and 0only). Contacts are installed in a wedge configuration forpositive make with minimum bounce.

    • Optional PF capacitor terminals—permit easy connectionof power factor correction capacitors between contactor andoverload relay for energy conservation.

    • Class 20 overload protection.• Visual trip indicator with manual reset—to avoid surprise

    restarts. Reset occurs on arm upstroke so a tripped conditioncan't be overridden by holding the arm down.

    • Manual weld check—provides a convenient test againstwelding of overload relay contacts. Just depress the weldcheck operator to trip the relay, run a simple continuity testacross the relay contacts, then depress the manual reset toreturn the starter to service.

    • Optional isolated NO contact on the overload relay-provides means of direct interface with programmable controlleror computer to monitor performance and diagnose faults.

    • Dual bimetals—anticipate overloads, responding to risingcurrent and temperature with faster tripping on severe overloadsfor better motor protection. Trip points are factory-calibratedfor accuracy.

    • ±10% trip adjustment—by turning a dial in the overload relayface allows "tuning" the protection to the motor on the spot.

    CR306 Size 1 Motor Starter with Solid-State Overload Relay Installed

    • Largest selection of modifications and accessory kits-includes auxiliary contacts, coils, fifth-pole addition, vertical andhorizontal mechanical interlocks, surge suppressors, controlcircuit fusing, NEMA Type enclosures, push buttons, selectorswitches, indicating lights, control transformers, space heaters,and more.

    Technical Features—Solid-State Overload• 2:1 Adjustable full load amps with tactile feedback dial• Selectable 10/20/30 protection class• Ambient insensitive within the stated operating temperature

    range of -20° to +70°C• Built-in thermal memory to prevent hot motor restarts• Protection against complete phase current loss• Phase current unbalance: Adjustable 20-50%• Manual reset (standard) and remote reset (optional) 24 Vdc or

    120 Vac• Accuracy: ±2%• Repeatability: ±2%• Self-powered @ 50% of minimum current range• Size: 1-6 (0.40A-540A, 600 V, 50/60 Hz)• Unbalance trip signal for PLC operation• Manual trip• Visual trip indication• Standard isolated 1 NO and 1 NC aux. contact (A600, Q600)• Built-in line/load straps• Fits with existing 300-Line Starters• Power factor correction terminals (sizes 1-4)• DIN rail mountable sizes 1 & 2

    1-4 1999 Issue Data subject to change without notice

  • GENEMA Rated Full Voltage Starter

    CR306, CR386 Nonreversing Magnetic Motor Starter,

    Typical CR306 Size 4magnetic motor starter

    ApplicationGE's magnetic motor starters listed here may be used for startingfull-voltage, nonreversing, single-speed ac motors up tp 1600horsepower, 600 Volts maximum, providing protection to themotor against running or stalled overloads.Their compact size and ease of wiring make them especiallysuitable for motor control centers, custom-type control panels,and switchgear equipment. Refer to page 1-4 for features of basicstarter.

    Ordering Directions1. Specify starter by complete Catalog Number.

    Example: CR306C103 is a Size 1 starter with 230-240-Volt,60-Hertz coil and in Type 1 general-purpose enclosure @$246.00, GO-10G.

    2. The final letter of the Catalog Number denotes extra auxiliarycontacts (sometimes referred to as auxiliary interlocks). Orderthe desired extra auxiliary contacts by replacing the final letterwith one from first column of auxiliary interlock table (see page1-58).Example: CR306C103AAB is Size 1 starter with one extranormally open, auxiliary contact @ $312.00, GO-10G.

    3. Starter forms are available with coils of other ratings than thoseshown on pages 1-6 to 1-7. Refer to coil suffix table, page 1-3for information. To order forms with other coil ratings, insertsuffix from coil table in place of fifth and sixth numbers oflisted starter Catalog Number shown on pages 1-6 to 1-7.Example: A CR306C102 NEMA Size 1, three-pole starter inType 1 enclosure with 24-Volt, 60-Hertz coil becomes aCR306C124 Catalog Number.

    4. For continuous rated motors with a service factor of 1 .15 to 1.25select the heater with maximum motor Amperes equal to orimmediately greater than the actual full-load current takendirectly from the nameplate of motor. Order heaters bycomplete Catalog Number from appropriate heater tables onpages 1-71 to 1-75. List Price $9.00 each, GO-10H. Packagedin quantities of three; must be ordered in multiples of three.

    Schematic Diagram

    1600 Horsepower MaximurrNEMA Sizes GO-

    600 Volts Maximurr50/60 Hert

    IT

    STOP START

    _d——— o-^NrO-

    OL 1

    ry-

    te

    a>

    \ "

    {OL i

    ^xlx

    OL>

    Typical Schematic Diagram for CR306 Starter(NEMA Sizes 00-6)

    5. Order special modifications or forms not listed by completedescription using a listed Catalog Number as reference.Example: Similar to CR306C104 except with 480/120-Voltcontrol transformer and red indicating light in cover.Total List P r i c e . . . . . . . . . . . . . . . . . . . . . . . . $483.00, GO-10G.

    6. Two-phase, four-wire forms are available. Contact nearestGE Industrial Systems—Electrical Distribution and ControlRepresentative for pricing and ordering information.

    Standard Coil RatingsStandard Voltages (60 Hertz):

    24,115-120, 200-208, 230-240, 265-277, 460-480 and 575-600Standard Voltages (50 Hertz):

    110, 220,380, 440 and 550For price adders on special voltage and/or frequency coils, referto page 1-52.

    50-Hertz StartersPricing of starters for use on 50 Hertz at standard voltages is thesame as shown in table for 60 Hertz. Refer to page 1-2 for three-phase horsepower ratings at 380 Volts, 50 Hertz.

    References:Instructions

    NEMA Size

    00,0,123456

    7-9

    Publication Number

    GEH-5190GEH-4774GEH-4806GEH-4807GEH-4839GEH-5198GEH-5108

    Factory-InstalledModifications.......... pages 1-50 to 1-56

    Field-InstalledModification Kits....... pages 1-57 to 1-61

    Heater SelectionTables ................ pages 1-71 to 1-75

    Prices and data subject to change without notice f 999 Issue 1-5