gea hilge contra€¦ · gea ·introduction to gea flow components 7 cleaning technology index,...

150
GEA Hilge CONTRA Single- and Multi-Stage Pumps Catalog 2018

Upload: others

Post on 12-Jul-2020

21 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hilge CONTRASingle- and Multi-Stage PumpsCatalog 2018

Page 2: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis
Page 3: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 3

Legal notice

Publication date: December 2018

The publication of specifications, technical data and information in written or electronic form does not release the user from the responsibility of checking for themselves all products delivered by us for suitability for the application(s) intended. These may be subject to change without prior notification. Errors and printing errors excepted – we assume no liability for the correctness of specifications given.

The general terms and conditions of delivery apply.

All rights reserved – copyright on all contents. GEA reserves the right to make technical changes to the information in this catalog.

GEA HilgeNiederlassung der GEA Tuchenhagen GmbHHilgestraße 37–47, 55294 Bodenheim, GermanyRegistered Office: Büchen, Court of Registration: HRB 836 SB in LübeckManagement Board: Tobias Dieckmann, Michael Wulle, Oliver HegehoferVAT-ID: DE 812589019, Tax No.: 105/5857/1004

Page 4: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

4 ·

GEA

Introduction to GEA Flow Components ......................................................................................................................................................................6

Hygienic PumpsIntroduction to Hygienic Pumps ....................................................................................................................................................................................8Certificates ......................................................................................................................................................................................................................... 26

GEA Hilge CONTRA PumpsOverview ............................................................................................................................................................................................................................. 29Product Range ................................................................................................................................................................................................................... 36Connection Guide............................................................................................................................................................................................................ 37Seals ...................................................................................................................................................................................................................................... 40Installation .......................................................................................................................................................................................................................... 42Media Guide ...................................................................................................................................................................................................................... 44Pump Selection Matrix ................................................................................................................................................................................................... 54Connection Dimensions ................................................................................................................................................................................................. 56

GEA Hilge CONTRA IPump Selection Matrix ................................................................................................................................................................................................... 62GEA Hilge CONTRA I Bloc – on Motor Foot ........................................................................................................................................................... 64GEA Hilge CONTRA I Bloc – on Combi Foot .......................................................................................................................................................... 65GEA Hilge CONTRA I Bloc – on Cast Iron Foot ..................................................................................................................................................... 66 GEA Hilge CONTRA I Bloc – on Stainless Steel Foot ............................................................................................................................................ 67 GEA Hilge CONTRA I Bloc - SUPER – on Combi Foot ............................................................................................................................................ 68GEA Hilge CONTRA I Bloc - SUPER – on Cast Iron Foot ....................................................................................................................................... 69 GEA Hilge CONTRA I Bloc - SUPER – on Stainless Steel Foot ............................................................................................................................. 70 GEA Hilge CONTRA I Bloc - V – on Vertical Stand ................................................................................................................................................. 71GEA Hilge CONTRA I Adapta / Adapta-tronic – on Combi Foot (80–90) ..................................................................................................... 72GEA Hilge CONTRA I Adapta / Adapta-tronic – on Combi Foot (100–132) ................................................................................................. 73 GEA Hilge CONTRA I Adapta / Adapta-tronic – on Cast Iron Foot ................................................................................................................. 74 GEA Hilge CONTRA I Adapta / Adapta-tronic – on Stainless Steel Foot ........................................................................................................ 75 GEA Hilge CONTRA I Adapta-SUPER – on Combi Foot (80–90) ..................................................................................................................... 76GEA Hilge CONTRA I Adapta-SUPER – on Combi Foot (100–132) ................................................................................................................. 77GEA Hilge CONTRA I Adapta-SUPER – on Cast Iron Foot ................................................................................................................................. 78 GEA Hilge CONTRA I Adapta-SUPER – on Stainless Steel Foot ....................................................................................................................... 79GEA Hilge CONTRA I Adapta / Adapta-tronic – on Vertical Stand .................................................................................................................. 80

Performance CurvesGEA Hilge CONTRA I, 32 / 32 (130 × 6) – 1-stage, 50 Hz ................................................................................................................................... 82GEA Hilge CONTRA I, 32 / 32 (130 × 6) – 2-stage, 50 Hz ................................................................................................................................... 83GEA Hilge CONTRA I, 32 / 32 (130 × 6) – 3-stage, 50 Hz ................................................................................................................................... 84GEA Hilge CONTRA I, 32 / 32 (130 × 6) – 4-stage, 50 Hz ................................................................................................................................... 85GEA Hilge CONTRA I, 32 / 32 (130 × 6) – 5-stage, 50 Hz ................................................................................................................................... 86GEA Hilge CONTRA I, 32 / 32 (130 × 6) – 6-stage, 50 Hz ................................................................................................................................... 87GEA Hilge CONTRA I, 40 / 40 (130 × 6) – 1-stage, 50 Hz ................................................................................................................................... 88GEA Hilge CONTRA I, 40 / 40 (130 × 6) – 2-stage, 50 Hz ................................................................................................................................... 89GEA Hilge CONTRA I, 40 / 40 (130 × 6) – 3-stage, 50 Hz ................................................................................................................................... 90GEA Hilge CONTRA I, 40 / 40 (130 × 6) – 4-stage, 50 Hz ................................................................................................................................... 91GEA Hilge CONTRA I, 40 / 40 (130 × 6) – 5-stage, 50 Hz ................................................................................................................................... 92GEA Hilge CONTRA I, 40 / 40 (130 × 6) – 6-stage, 50 Hz ................................................................................................................................... 93GEA Hilge CONTRA I, 32 / 32 (130 × 6) – 1-stage, 60 Hz ................................................................................................................................... 94GEA Hilge CONTRA I, 32 / 32 (130 × 6) – 2-stage, 60 Hz ................................................................................................................................... 95GEA Hilge CONTRA I, 32 / 32 (130 × 6) – 3-stage, 60 Hz ................................................................................................................................... 96GEA Hilge CONTRA I, 32 / 32 (130 × 6) – 4-stage, 60 Hz ................................................................................................................................... 97GEA Hilge CONTRA I, 40 / 40 (130 × 6) – 1-stage, 60 Hz ................................................................................................................................... 98GEA Hilge CONTRA I, 40 / 40 (130 × 6) – 2-stage, 60 Hz ................................................................................................................................... 99GEA Hilge CONTRA I, 40 / 40 (130 × 6) – 3-stage, 60 Hz .................................................................................................................................100GEA Hilge CONTRA I, 40 / 40 (130 × 6) – 4-stage, 60 Hz .................................................................................................................................101

Contents Pages

Page 5: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 5

GEA

Contents Pages

GEA Hilge CONTRA IIPump Selection Matrix .................................................................................................................................................................................................102GEA Hilge CONTRA II Bloc – on Motor Foot ........................................................................................................................................................104GEA Hilge CONTRA II Bloc – on Combi Foot (90–132) ....................................................................................................................................105 GEA Hilge CONTRA II Bloc – on Combi Foot (160) ............................................................................................................................................106GEA Hilge CONTRA II Bloc – on Cast Iron Foot ..................................................................................................................................................107GEA Hilge CONTRA II Bloc – on Stainless Steel Foot .........................................................................................................................................108 GEA Hilge CONTRA II Bloc - SUPER – on Combi Foot (90–132) ......................................................................................................................109 GEA Hilge CONTRA II Bloc - SUPER – on Combi Foot (160) .............................................................................................................................110GEA Hilge CONTRA II Bloc - SUPER – on Cast Iron Foot ....................................................................................................................................111GEA Hilge CONTRA II Bloc - SUPER – on Stainless Steel Foot ..........................................................................................................................112GEA Hilge CONTRA II Bloc - V – on Vertical Stand ..............................................................................................................................................113 GEA Hilge CONTRA II Adapta / Adapta-tronic – on Combi Foot ...................................................................................................................114GEA Hilge CONTRA II Adapta / Adapta-tronic – on Adjustable Feet (160).................................................................................................115GEA Hilge CONTRA II Adapta / Adapta-tronic – on Adjustable Feet (180) ................................................................................................116GEA Hilge CONTRA II Adapta / Adapta-tronic – on Cast Iron Foot ..............................................................................................................117GEA Hilge CONTRA II Adapta / Adapta-tronic – on Stainless Steel Foot .....................................................................................................118 GEA Hilge CONTRA II Adapta / Adapta-tronic – on Adapta Foot ..................................................................................................................119GEA Hilge CONTRA II Adapta-SUPER – on Combi Foot ...................................................................................................................................120GEA Hilge CONTRA II Adapta-SUPER – on Adjustable Feet (160) ................................................................................................................121GEA Hilge CONTRA II Adapta-SUPER – on Adjustable Feet (180) ................................................................................................................122GEA Hilge CONTRA II Adapta-SUPER – on Cast Iron Foot ..............................................................................................................................123GEA Hilge CONTRA II Adapta-SUPER – on Stainless Steel Foot ....................................................................................................................124 GEA Hilge CONTRA II Adapta / Adapta-tronic – on Vertical Stand ...............................................................................................................125

Performance CurvesGEA Hilge CONTRA II, 50 / 50 (175 × 6) – 2-stage, 50 Hz ................................................................................................................................126GEA Hilge CONTRA II, 50 / 50 (175 × 6) – 3-stage, 50 Hz ................................................................................................................................127GEA Hilge CONTRA II, 50 / 50 (175 × 6) – 4-stage, 50 Hz ................................................................................................................................128GEA Hilge CONTRA II, 50 / 50 (175 × 6) – 5-stage, 50 Hz ................................................................................................................................129GEA Hilge CONTRA II, 65 / 65 (175 × 6) – 2-stage, 50 Hz ................................................................................................................................130GEA Hilge CONTRA II, 65 / 65 (175 × 6) – 3-stage, 50 Hz ................................................................................................................................131GEA Hilge CONTRA II, 65 / 65 (175 × 6) – 4-stage, 50 Hz ................................................................................................................................132GEA Hilge CONTRA II, 65 / 65 (175 × 6) – 5-stage, 50 Hz ................................................................................................................................133GEA Hilge CONTRA II, 50 / 50 (175 × 6) – 2-stage, 60 Hz ................................................................................................................................134GEA Hilge CONTRA II, 50 / 50 (175 × 6) – 3-stage, 60 Hz ................................................................................................................................135GEA Hilge CONTRA II, 50 / 50 (175 × 6) – 4-stage, 60 Hz ................................................................................................................................136GEA Hilge CONTRA II, 50 / 50 (175 × 6) – 5-stage, 60 Hz ................................................................................................................................137GEA Hilge CONTRA II, 65 / 65 (175 × 6) – 2-stage, 60 Hz ................................................................................................................................138GEA Hilge CONTRA II, 65 / 65 (175 × 6) – 3-stage, 60 Hz ................................................................................................................................139GEA Hilge CONTRA II, 65 / 65 (175 × 6) – 4-stage, 60 Hz ................................................................................................................................140GEA Hilge CONTRA II, 65 / 65 (175 × 6) – 5-stage, 60 Hz ................................................................................................................................141

AppendixInquiry Sheet ....................................................................................................................................................................................................................142Description of Certificates and Test Reports ........................................................................................................................................................144Abbreviations and Terms .............................................................................................................................................................................................145

Page 6: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA

6 ·

GEA Group Aktiengesellschaft GEA is one of the largest suppliers of process technology for the food industry and for a wide range of other industries. As an international technology group, the company focuses on world-leading process solutions and components for sophisticated production processes.

Regardless of the application – for our customers product quality and profitability are what matters. This is what GEA Flow Components is known for. Our engineers are specialists in everything that flows.

GEA Flow Components GEA offers well-engineered process components and services to ensure smooth production processes in the treatment of liquid products. We develop and produce a comprehensive product range that includes valve technology for all hygienic classes (Hygienic, UltraClean, Aseptic), hygienic pumps and cleaning technology.

GEA Flow Components products and services are available around the world through the international GEA network.

Around one quarter of the milk processed is handled by GEA equipment

Roughly every second liter of beer is brewed using GEA equipment and solutions

Every fourth liter of human blood is handled by GEA equipment

Introduction to GEA Flow Components

Page 7: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA

· 7

Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis on saving valuable resources in the cleaning process.

Hygienic Pump Technology A great variety of Hygienic pumps with sensibly rated high efficiency motors and carefully designed flow paths, driving economic efficiency and sustainable operation.

Hygienic Valve Technology A complete range of economically designed Hygienic valves for complex tasks as well as basic functions, helping producers to achieve high product quality and efficiency.

Aseptic Valve Technology UltraClean and Aseptic valves are suitable for production processes which require a higher safety protection against contamination from the environment and thus warrant microbial stability of the product over the whole process.

State-of-the-art hygienic design

GEA Flow Components meet the highest hygienic standards where required, such as EHEDG and 3-A standards.

Hygienic valves and components from GEA form the core component of matrix-piped process plants.

When it comes to sterile applications, GEA offers both UltraClean and Aseptic valves and systems. The hermetic sealing of the product area provides a maximum level of process line isolation and thus contributes to process and product safety.

The hygienic pump range from GEA includes centrifugal pumps (single-stage, multi-stage and self-priming), as well as rotary lobe pumps.

GEA cleaning devices – whether index, orbital, rotary or static – achieve optimum cleaning results in multiple industries. GEA product recovery systems help to recover valuable products and reduce both waste disposal costs as well as water and detergent consumption.

Applications

• Beverages – Beer, juice, smoothies, and more

• Dairy processing – Milk, yoghurt, cheese, and more

• Food – Sauces, pastes, ketchup, mayonnaise, and more

• Pharma/Biotech – Pharmaceuticals, biotech, cosmetics, health care, and more

• Chemicals – Fine chemicals, bulk chemicals, cleaning agents, and more

Introduction to GEA Flow Components

Page 8: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

8 ·

Maximum reliability and cost control Because GEA customers rely on the safe, continuous operation of their production systems, GEA pumps are optimized for uncompromising reliability in all applications. The great number of pumps currently in operation is proof of their robust design, long service life and ease of maintenance.

Applying GEA pumps to production processes can significantly reduce operational costs. Sensibly rated high-efficiency motors in all the required dimensions keep energy consumption as low as possible. The product is conveyed evenly and gently for higher product quality and improved processing and distribution options.

Gentle product handling, continued reliability and economic efficiency are key characteristics of the state-of-the-art hygienic pumps in the GEA Flow Components range.

Economical

Higher product quality

Reduced consumption of energy, water and cleaning media

Reduced time and personnel costs for maintenance and cleaning

Introduction to Hygienic Pumps

Page 9: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

· 9

Hygienic and sustainable design GEA pumps comply with all relevant hygiene standards and norms, with continuous documentation and up-to-date certifications safely ensuring judicial security.

Carefully designed flow paths free of dead zones ensure optimum cleaning and utilization of the conveying energy. Lower consumption of energy, water and chemicals helps to protect climate and environment, observe international regulations and promote the producer’s standing with customers and authorities.

Long-term partnership The GEA Hilge Hygienic Pumps Competence Center situated in Bodenheim, Germany, is the primary point of contact for GEA customers and partners to plan individual solutions. The worldwide GEA sales and service network provides further assistance with support offers covering the entire lifecycle of the pump.

Sustainable

Lower climate and environmental impact

Sustainable, environmentally friendly production processes

High standards for hygienic processing and care of products

Service-oriented

Individual engineering support

Shortest possible downtime of production

Individual service concept

Introduction to Hygienic Pumps

Page 10: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

10 ·

Complex applications with advanced requirements

High system pressures,high media temperatures,

high solid content in media,highest requirements regarding surface

quality and materials

Standard applications with low complexity

System pressures up to 16 bar,low media temperatures,

non-critical conveying media,standard requirements regarding surface

quality and materials

GEA SMARTPUMP

GEA VARIPUMP

Com

plex

ity

of c

usto

mer

app

licat

ion

Degree of user-specific adjustment

Standard pump typesPre-defined model variants for common applications

High flexibilityIndividual adjustment,

custom engineering

Two modern pump lines for maximum efficiency Two product lines, GEA VARIPUMP and GEA SMARTPUMP, form a highly versatile pump range with a multitude of adaption options to ensure simpler operation, higher-quality production, and reduced consumption of valuable resources.

Introduction to Hygienic Pumps

Page 11: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

· 11

The pump series in the GEA VARIPUMP line have been conceived for extreme application demands. The pumps are individually optimized by GEA for each task.

GEA VARIPUMP models are made entirely without die-cast components, offering high-quality surfaces and materials that meet stringent demands even in the sensitive pharmaceutical industry, further ensured by complementing services, e.g. Witnessed Factory Acceptance Test (FAT).

With a great variety of set-up and customizing options the pumps can be adapted individually to any production process, for lower operational costs and maximum system efficiency.

• Developed for advanced application conditions• Project-specific customization• Surface roughness up to Ra ≤ 0.4 µm• Product-wetted materials according to specific requirements

(e.g. no cast parts, Fe ≤ 1 % optional)

The GEA SMARTPUMP line comprises highly standardized and attractively priced pump series for common, often-used applications at standard conditions. The pumps are easy to select and ready for fast delivery. Within pre-defined parameters, the standard models can be configured to individual tasks.

The modular construction using high-value materials, the proven “Hygienic Design” and easy-to-apply standardized spare parts all recommend GEA SMARTPUMP pumps for use in cost-critical production systems – at no compromise in terms of quality.

• Application for common and clearly defined “standard” process tasks

• Simple selection and configuration • Fast delivery• Standardized spare parts

GEA VARIPUMP GEA SMARTPUMP

Introduction to Hygienic Pumps

Page 12: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

12 ·

* GEA Hilge HYGIA & GEA Hilge MAXA (up to 150/400)

Introduction to Hygienic Pumps Performance Curves

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

60

80

100

120

0

40

20

300

200

150

250

100

50

0

350

[US gpm]0 150 300 450 600 750 900 12001050 1350

70

60

0

40

30

10

20

50

75

50

25

0

100

125

150

175

200

[US gpm]0 750250 1000500 1250 1500

0 450200100 300 40025015050 350

0 350100 200 250 30050 150

GEA VARIPUMP PERFORMANCE CURVE2-POLIG, 50 HZ (HYGIA/MAXA)

GEA VARIPUMP PERFORMANCE CURVE4-POLIG, 50 HZ (HYGIA/MAXA)

Single-stage, VARIPUMP 2-pole, 50 Hz

Single-stage, VARIPUMP* 4-pole, 50 Hz

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

60

80

100

120

0

40

20

300

200

150

250

100

50

0

350

[US gpm]0 150 300 450 600 750 900 12001050 1350

70

60

0

40

30

10

20

50

75

50

25

0

100

125

150

175

200

[US gpm]0 750250 1000500 1250 1500

0 450200100 300 40025015050 350

0 350100 200 250 30050 150

GEA VARIPUMP PERFORMANCE CURVE2-POLIG, 50 HZ (HYGIA/MAXA)

GEA VARIPUMP PERFORMANCE CURVE4-POLIG, 50 HZ (HYGIA/MAXA)

Page 13: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

· 13

* GEA Hilge MAXA 200/400 and 250/400

Introduction to Hygienic Pumps Performance Curves

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

40

50

60

70

30

0

20

10

180

80

60

100

120

140

160

40

20

0

200

220

[US gpm]0 1000 2000 3000 4000 5000 6000

120

80

100

0

60

40

20

150

100

50

0

200

250

300

350

[US gpm]0 600200 800400 1000 1200 1400

0 350200100 30025015050

0 1600400 800 1000 1200 1400200 600

GEA VARIPUMP PERFORMANCE CURVE4+6-POLIG, 50 HZ (MAXA)

GEA VARIPUMP PERFORMANCE CURVE2-POLIG, 60 HZ (HYGIA/MAXA)

Single-stage, VARIPUMP* 4- and 6-pole, 50 Hz

Page 14: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

14 · Introduction to Hygienic Pumps Performance Curves

Single-stage, VARIPUMP 2-pole, 60 Hz

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

40

50

60

70

30

0

20

10

180

80

60

100

120

140

160

40

20

0

200

220

[US gpm]0 1000 2000 3000 4000 5000 6000

120

80

100

0

60

40

20

150

100

50

0

200

250

300

350

[US gpm]0 600200 800400 1000 1200 1400

0 350200100 30025015050

0 1600400 800 1000 1200 1400200 600

GEA VARIPUMP PERFORMANCE CURVE4+6-POLIG, 50 HZ (MAXA)

GEA VARIPUMP PERFORMANCE CURVE2-POLIG, 60 HZ (HYGIA/MAXA)

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

60

70

80

90

100

40

50

0

30

20

10

300

200

150

250

100

50

0

[US gpm]0 250 500 750 1000 1250 1500 1750 2000 2250

45

40

0

30

20

10

35

25

15

5

50

25

0

75

100

125

[US gpm]0 30001000 40002000 5000 6000

0 1600800400 12001000600200 1400

0 600100 300 400 500200

GEA VARIPUMP PERFORMANCE CURVE4-POLIG, 60 HZ (HYGIA/MAXA)

GEA VARIPUMP PERFORMANCE CURVE6-POLIG, 60 HZ (MAXA)

Single-stage, VARIPUMP 4-pole, 60 Hz

Page 15: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

· 15Introduction to Hygienic Pumps Performance Curves

Single-stage, VARIPUMP 6-pole, 60 Hz

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

60

70

80

90

100

40

50

0

30

20

10

300

200

150

250

100

50

0

[US gpm]0 250 500 750 1000 1250 1500 1750 2000 2250

45

40

0

30

20

10

35

25

15

5

50

25

0

75

100

125

[US gpm]0 30001000 40002000 5000 6000

0 1600800400 12001000600200 1400

0 600100 300 400 500200

GEA VARIPUMP PERFORMANCE CURVE4-POLIG, 60 HZ (HYGIA/MAXA)

GEA VARIPUMP PERFORMANCE CURVE6-POLIG, 60 HZ (MAXA)

Page 16: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

16 ·

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

100

120

140

160

180

80

0

60

40

20

600

400

300

500

200

100

0

[US gpm]0 25 50 75 100 125 150 175

250

200

0

150

100

50

300

200

100

0

400

500

600

700

800

[US gpm]0 7525 10050 125 150

0 402010 3025155 35

0 4510 20 25 30 35 405 15

GEA CONTRA PERFORMANCE CURVE2-POLIG, 50 HZ

GEA CONTRA PERFORMANCE CURVE2-POLIG, 60 HZ

Multi-stage, VARIPUMP 2-pole, 50 Hz

Multi-stage, VARIPUMP 2-pole, 60 Hz

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

100

120

140

160

180

80

0

60

40

20

600

400

300

500

200

100

0

[US gpm]0 25 50 75 100 125 150 175

250

200

0

150

100

50

300

200

100

0

400

500

600

700

800

[US gpm]0 7525 10050 125 150

0 402010 3025155 35

0 4510 20 25 30 35 405 15

GEA CONTRA PERFORMANCE CURVE2-POLIG, 50 HZ

GEA CONTRA PERFORMANCE CURVE2-POLIG, 60 HZ

Introduction to Hygienic Pumps Performance Curves

Page 17: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

· 17

Single-stage, SMARTPUMP 2-pole, 50 Hz

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

50

60

70

80

90

100

40

0

30

20

10

300

200

150

250

100

50

0

[US gpm]0 10050 200 300 400 500 600150 250 350 450 550 650 700

0 5025 100 150 200 250 30075 125 175 225 275 325 35025

20

0

15

10

5

30

20

10

0

40

50

60

70

80

[US gpm]

0 902010 706030 40 50 80

0 18040 80 100 120 140 16020 60

GEA SMARTPUMP PERFORMANCE CURVE 2-POLIG, 50 HZ (TP)

GEA SMARTPUMP PERFORMANCE CURVE 4-POLIG, 50 HZ (TP)

Single-stage, SMARTPUMP 4-pole, 50 Hz

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

50

60

70

80

90

100

40

0

30

20

10

300

200

150

250

100

50

0

[US gpm]0 10050 200 300 400 500 600150 250 350 450 550 650 700

0 5025 100 150 200 250 30075 125 175 225 275 325 35025

20

0

15

10

5

30

20

10

0

40

50

60

70

80

[US gpm]

0 902010 706030 40 50 80

0 18040 80 100 120 140 16020 60

GEA SMARTPUMP PERFORMANCE CURVE 2-POLIG, 50 HZ (TP)

GEA SMARTPUMP PERFORMANCE CURVE 4-POLIG, 50 HZ (TP)

Introduction to Hygienic Pumps Performance Curves

Page 18: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

18 · Introduction to Hygienic Pumps Performance Curves

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

100

120

140

160

80

0

60

40

20

300

200

400

100

0

500

[US gpm]0 200 300 400 600100 500 700 800 900 1000

40

30

0

20

10

35

25

15

520

0

40

60

80

100

120

[US gpm]0 30010050 400200 450 500350150 250 550

0 1406040 1008020 120

0 25050 100 125 150 175 22520025 75

GEA SMARTPUMP PERFORMANCE CURVE2-POLIG, 60 HZ (TP)

GEA SMARTPUMP PERFORMANCE CURVE4-POLIG, 60 HZ (TP)

Single-stage, SMARTPUMP 2-pole, 60 Hz

Single-stage, SMARTPUMP 4-pole, 60 Hz

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

100

120

140

160

80

0

60

40

20

300

200

400

100

0

500

[US gpm]0 200 300 400 600100 500 700 800 900 1000

40

30

0

20

10

35

25

15

520

0

40

60

80

100

120

[US gpm]0 30010050 400200 450 500350150 250 550

0 1406040 1008020 120

0 25050 100 125 150 175 22520025 75

GEA SMARTPUMP PERFORMANCE CURVE2-POLIG, 60 HZ (TP)

GEA SMARTPUMP PERFORMANCE CURVE4-POLIG, 60 HZ (TP)

Page 19: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

· 19Introduction to Hygienic Pumps Performance Curves

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

50

60

70

80

40

0

30

20

10

200

150

250

100

50

0

[US gpm]

45

40

0

30

20

10

35

25

15

5

25

0

50

75

100

125

[US gpm]0 155 2010 25 30 35

0 155 2010 25 30 35

0 953 76421 8

0 92 4 5 6 7 81 3

GEA SMARTPUMP PERFORMANCE CURVE2-POLIG, 50 HZ (DURIETTA)

GEA SMARTPUMP PERFORMANCE CURVE2-POLIG, 60 HZ (DURIETTA)

Multi-stage, SMARTPUMP 2-pole, 50 Hz

Multi-stage, SMARTPUMP 2-pole, 60 Hz

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

50

60

70

80

40

0

30

20

10

200

150

250

100

50

0

[US gpm]

45

40

0

30

20

10

35

25

15

5

25

0

50

75

100

125

[US gpm]0 155 2010 25 30 35

0 155 2010 25 30 35

0 953 76421 8

0 92 4 5 6 7 81 3

GEA SMARTPUMP PERFORMANCE CURVE2-POLIG, 50 HZ (DURIETTA)

GEA SMARTPUMP PERFORMANCE CURVE2-POLIG, 60 HZ (DURIETTA)

Page 20: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

20 · Introduction to Hygienic Pumps Performance Curves

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

30

35

40

45

50

20

25

0

15

10

5

100

50

0

150

[US gpm]0 50 100 150 200 250 300 350

70

60

0

40

50

30

10

20

50

0

100

150

200

[US gpm]0 100 15050 200 250

0 703010 504020 60

0 9020 40 50 60 70 8010 30

GEA VARIPUMP PERFORMANCE CURVE4-POLIG, 50 HZ (SIPLA)

GEA VARIPUMP PERFORMANCE CURVE4-POLIG, 60 HZ (SIPLA)

Single-stage, self-priming, VARIPUMP 4-pole, 50 Hz

Single-stage, self-priming, VARIPUMP 4-pole, 60 Hz

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

30

35

40

45

50

20

25

0

15

10

5

100

50

0

150

[US gpm]0 50 100 150 200 250 300 350

70

60

0

40

50

30

10

20

50

0

100

150

200

[US gpm]0 100 15050 200 250

0 703010 504020 60

0 9020 40 50 60 70 8010 30

GEA VARIPUMP PERFORMANCE CURVE4-POLIG, 50 HZ (SIPLA)

GEA VARIPUMP PERFORMANCE CURVE4-POLIG, 60 HZ (SIPLA)

Page 21: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

· 21Introduction to Hygienic Pumps Performance Curves

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

50

60

70

80

90

100

40

0

30

20

10

300

200

150

250

100

50

0

[US gpm]0 25 50 22575 100 200125 150 175 250 275

0 25 50 22575 100 200125 150 175 250 275120

100

0

80

40

60

20

150

100

50

0

200

250

300

350

[US gpm]

0 703010 504020 60

0 7010 20 5030 40 60

GEA SMARTPUMP PERFORMANCE CURVE4-POLIG, 50 HZ (TPS)

GEA SMARTPUMP PERFORMANCE CURVE4-POLIG, 60 HZ (TPS)

Single-stage, self-priming, SMARTPUMP 2-pole, 50 Hz

Single-stage, self-priming, SMARTPUMP 2-pole, 60 Hz

Q [m3/h]

Q [m3/h]

H[m][ft]

H[m][ft]

50

60

70

80

90

100

40

0

30

20

10

300

200

150

250

100

50

0

[US gpm]0 25 50 22575 100 200125 150 175 250 275

0 25 50 22575 100 200125 150 175 250 275120

100

0

80

40

60

20

150

100

50

0

200

250

300

350

[US gpm]

0 703010 504020 60

0 7010 20 5030 40 60

GEA SMARTPUMP PERFORMANCE CURVE4-POLIG, 50 HZ (TPS)

GEA SMARTPUMP PERFORMANCE CURVE4-POLIG, 60 HZ (TPS)

Page 22: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

22 · Introduction to Hygienic Pumps Performance Curves

Q [m3/h]

P[bar][psi]

18

20

14

0

10

6

2

200

160

120

40

0

240

[US gpm]0 50 100 150 200 250

0 7010 20 5030 6040

16

12

8

4

80

280

GEA ROTARY LOBE PUMP PERFORMANCE CURVE2-POLE, 60 HZ (VARIPUMP)

Rotary Lobe Pump, VARIPUMP

Page 23: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis
Page 24: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA

24 · Introduction to Hygienic Pumps

GEA Hilge HYGIA / HYGIA H

The “Swiss Knife” among the hygienic

pumps. Premium quality and highest

flexibility of customization ensure

successful application in the food,

beverage, and pharma industries. Also

available as high-pressure execution.

GEA Hilge MAXA

A single-stage centrifugal pump designed

for heavy-duty operation in industrial

processes. The major dimensions and

characteristics of these pumps correspond

to DIN EN 733 and DIN EN 22858.

GEA Hilge TP

The GEA Hilge TP is the smart solution

for standard applications. The single-stage

centrifugal pump suits a wide range of

applications and offers uncompromising

hygiene and quality.

Technical data 50 Hz 60 Hz

Flow rate 200 m3/h 175 m3/h

Flow head 72 m 105 m

System pressure 16 / 25 / 64 bar

Clearly defined list of models, limited to

standard requirements, no other variants

Wide model range with numerous variants.

Customization to specific customer requirements

GEA

VA

RIPU

MP

GEA

SM

ART

PUM

P

Technical data 50 Hz 60 Hz

Flow rate 1,450 m3/h 1,320 m3/h

Flow head 100 m 100 m

System pressure 10 bar

Technical data 50 Hz 60 Hz

Flow rate 210 m3/h 240 m3/h

Flow head 90 m 130 m

System pressure 16 bar

Single-stage end-suction centrifugal pumps

GEA

Hilg

e M

AX

A

GEA

Hilg

e H

YGIA

GEA

Hilg

e TP

Page 25: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

Hygienic Pumps

· 25 Overview

GEA Hilge SIPLA

A single-stage self-priming side channel

pump, especially suited for SIP/CIP return

systems and applications with high gas content.

Right- and left-hand rotation can be freely

adjusted for additional application options.

GEA Hilge CONTRA

Single- and multi-stage centrifugal pumps

are available in this series. The hygienic

design in every detail provides perfect

solutions to numerous tasks in sterile and

hygienic processes.

GEA Hilge NOVALOBE

This rotary lobe pump has been

specifically designed for highly viscous

media – and for applications where gentle

pumping or dosing is required. The pump

is fully drainable and EHEDG certified.

GEA Hilge TPS

This self-priming centrifugal pump is

the solution of choice especially for

emptying tanks as well as for conveying

products containing gas, e.g. CIP

return systems.

GEA Hilge DURIETTA

This end-suction single- or multi-

stage centrifugal pump in a very

compact design has been created for

applications with low flow rates at

high flow heads.

Technical data 50 / 60 Hz

Cavity volume 2.1 rev

System pressure 10/16 bar

Multi-stage centrifugal pumps

Single-stage self-priming centrifugal pumps

GEA

Hilg

e SI

PLA

GEA

Hilg

e C

ON

TRA

Rotary lobe pumps

GEA

Hilg

e TP

S

GEA

Hilg

e D

URI

ETTA

Technical data 50 Hz 60 Hz

Flow rate 78 m3/h 64 m3/h

Flow head 47 m 60 m

System pressure 10 bar

Technical data 50 Hz 60 Hz

Flow rate 40 m3/h 35 m3/h

Flow head 160 m 230 m

System pressure 25 bar

Technical data 50 Hz 60 Hz

Flow rate 125 m3/h 155 m3/h

Flow head 95 m 138 m

System pressure 16 bar

Technical data 50 Hz 60 Hz

Flow rate 8 m3/h 8 m3/h

Flow head 72 m 41 m

System pressure 8 bar

GEA

Hilg

e N

OVA

LOBE

Page 26: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA Hygienic Pumps

26 ·

The certificates listed here are valid for corresponding GEA pump models. Pumps conforming to the requirements of the European Hygienic Engineering and Design Group (EHEDG) as well as 3-A Sanitary Standards, Inc. (3-A SSI) are available for numerous fields of application.

EHEDG certificates apply only to the specific pump type as listed. However, they may be transferred to specific other pump types, owing to identical housing designs and flow path geometries.

Moreover, independent, standardized tests have confirmed the efficient, problem-free cleaning ability of numerous pumps – for optimum safety and economic gain.

Certificates

Document

GEA

Hilg

e

HYG

IA /

H

YGIA

H

GEA

Hilg

e

TP /

TPS

GEA

Hilg

e C

ON

TRA

GEA

Hilg

e M

AX

A

GEA

Hilg

e D

URI

ETTA

GEA

Hilg

e SI

PLA

GEA

Hilg

e N

OVA

LOBE

3-A Sanitary Standard • •

EHEDG certificate •* • •* •*

FDA declaration of conformity • • • • • • •

Declaration of compliance with the order 2.1 acc. to EN 10204 • • • • • •

Test report 2.2 acc. to EN 10204 • • • • • • •

Inspection certificate 3.1 acc. to EN 10204 • • • • • •

EAC-Certificate • • • • • • •

Surface roughness test report • • • • •

Delta ferrite test report • • •

Acoustic measurement test report • • • • • • •

USP Class VI – declaration of conformity • • • • •

Certificate in acc. with the regulation (EG) No. 1935/2004 • • • • • • •

Certificate DIN EN ISO 9001:2015 • • • • • • •

Many more certificates on request Subject to change without notice. * registered for certification / recertification

Page 27: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis
Page 28: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis
Page 29: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 29

GEA

Overview GEA Hilge CONTRA I / II

Design

GEA Hilge CONTRA pumps are single- and multi-stage, end-suction centrifugal pumps, designed to meet the hygienic requirements of sterile process technology.

The pump casing is made of heavy-duty, rolled and deep-drawn and forged CrNiMo steel 1.4404 / 1.4435, the equivalent of AISI 316L. The GEA Hilge CONTRA pumps are equipped with open diffusor casings. The O-ring seal loctions for the casing and impellers meet hygienic design criteria. The vertical versions of GEA Hilge CONTRA pumps are fully self-draining through the suction port.

The special groove ensures that the seal is kept reliably in place at all times. The metallic stop allows a defined compression of the seal, ensuring gap-free sealing against the product chamber without dead legs. The pumps have a mechanical seal and a fan-cooled asynchronous motor to enclosure class IP55.

Pump connections

GEA Hilge offers the following standard connections for theGEA Hilge CONTRA pump range:• Thread according to DIN 11851• Flanges according to DIN 11864-2

You can find additional information in the connectionselection guide on page 37.

The pumps are available in two sizes with a variety of flexibleversions. The pumps are CIP- and SIP-capable in compliancewith the DIN EN 12462 performance criteria. The designfulfills the following requirements:• QHD criteria• EHEDG (registered for recertification)• EAC• GMP regulations

GEA Hilge CONTRA on Stainless Steel Adjustable Feet

Technical Data

GEA Hilge CONTRA I

GEA Hilge CONTRA II

50 Hz 60 HZ 50 Hz 60 Hz

Flow head 100 m 100 m 160 m 230 m

Flow rate 12 m3/h 15 m3/h 40 m3/h 35 m3/h

System pressure up to 25 bar

Operating temperature 95 °C

Sterilisation temperature 150 °C (SIP)

Max. pump efficiency 58 %

Applications

The GEA Hilge CONTRA pump range is suitable for the following application areas and products due to the hygienic design and material selection:

Food and beverage industry• Breweries (beer, wort, mash, yeast, etc.)• Dairies (milk, milk-based mixed beverages, cheese

manufacturing, etc.)• Soft drinks (fruit juice, lemonade, mineral water, etc.)• Wine and champagne cellars• Distilleries (mash, distillates, etc.)• Food manufacturing (marinades, brine, cooking oil, etc.)• Cleaning In Place systems (CIP)

Pharmaceutical and biotechnology• Pure-water systems (WFI)• Infusion• Culture medium• Blood plasma• Lotions• Perfumes

ATEX-Symbol

GEA Hilge CONTRA Pumps

ATEX

For use in potentially explosive areas, Adapta pumps are available. These pumps, which possess an EC declaration of conformity in accordance with the ATEX guideline 2014/34/EU, correspond to device categories 2 or 3, and can be used in zone 1 or 2.

Certification

Page 30: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

30 ·

GEA GEA Hilge CONTRA Pumps

Overview GEA Hilge CONTRA I / II

Impeller version Surface finish

Cast Ra ≤ 3.2 µm

Milled Ra ≤ 0.8 – 0.4 µm

Impeller

Semi-open impeller

The electro-polished, stainless steel, semi-open impeller is available in two versions, according to the application.

The impeller is suitable for low-viscosity liquids and liquids containing low content of particles.

Materials

Materials overview GEA Hilge CONTRA

Item Component Material No.

1 Impeller CrNiMo steel 316L (1.4404 /1.4435)

2 Pump casing CrNiMo steel 316L (1.4404 /1.4435)

3 Seal

Single mechanical seal carbon/stainless steel or SiC/SiC,other versions available on request

4 Pump shaft CrNiMo steel 316Ti (1.4571)

5 Motor Aluminum

6 Foot Iron/stainless steel

Shroud Stainless steel

1

23

45

6

Page 31: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 31

GEA GEA Hilge CONTRA Pumps

Overview GEA Hilge CONTRA I / II

Coating

Components not made of stainless steel are provided with oneof the following coatings, depending on the design:

Mechanical seal

GEA Hilge offers the following seal designs:• Single mechanical seal• Single mechanical seal, flushed (Quench)• Double mechanical seal, tandem• Double mechanical seal, back-to-back

The pumps of the GEA Hilge CONTRA range are equipped with single internal mechanical seals optimally arranged in the pump.

This ensures efficient lubrication and cooling of the mechanical seal. CIP and SIP-capability is fulfilled according to hygienic design criteria.

The standard material for the mechanical seals is carbon/stainless steel with EPDM elastomers. Other executions and materials are available on request.

For further information on mechanical seals, see page 40.

Version Paint/coating Coating thickness

Primer 2K epoxy resin 30 – 60 µm

KTL coating 15–20 µm

Top coating 2K epoxy resin 50–70 µm

2K polyurethane color 60 µm

KTL coating 15 – 20 µm

Surface design Selected components are electro-polished in order to improvethe surface and protect it against corrosion.

Lantern (motor stool) and cast impeller not electro-polished.

Clamp ring

Surface Electro-polished components

Ra ≤ 3.2 µm Casing and Impeller optional

Ra ≤ 0.8 µm Casing and Impeller

Ra ≤ 0.8 µmAll components that come into contact with the pumped fluid

Ra ≤ 0.4 µmAll components that come into contact with the pumped fluid

Casing design The special groove ensures that the seal is kept reliably in place at all times. The metallic stop allows a defined compression of the seal, ensuring gap-free sealing against the product chamberwithout dead legs.

Page 32: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

32 ·

GEA GEA Hilge CONTRA Pumps

Overview GEA Hilge CONTRA I / II

Design variants

Bloc DesignGEA Hilge sterile and process pumps in compact Bloc designrequire small installation space. The motor is equipped with an extended stainless steel pump shaft.

GEA Hilge CONTRA Bloc on Combi FootGEA Hilge CONTRA Bloc on Cast Iron Foot

The modular design enables numerous installation designs.Pumps in the Bloc-SUPER design are equipped with stainless steel shrouds.

Standard version Description

GEA Hilge CONTRA Bloc Horizontal installation, close-coupled pump, motor with extended stainless steel shaft

GEA Hilge CONTRA Bloc-SUPERHorizontal installation, close-coupled pump, motor with extended stainless steel shaft and stainless steel shroud

GEA Hilge CONTRA Bloc-V Vertical installation, close-coupled pump, motor with extended stainless steel shaft

GEA Hilge CONTRA Bloc-SUPER on Combi Foot

Page 33: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 33

GEA GEA Hilge CONTRA Pumps

Overview GEA Hilge CONTRA I / II

Adapta designPumps in Adapta design have a bearing bracket with a double supported shaft. The connection between the pump shaft and the motor shaft is coupled with an elastic coupling. This design enables the use of various standard motors. The pump can remain in the system during engine demounting/mounting.

Standard version Description

GEA Hilge CONTRA Adapta Horizontal installation, mounted pump shaft, standard motor

GEA Hilge CONTRA Adapta-SUPER Horizontal installation, mounted pump shaft, standard motor with stainless steel shroud

GEA Hilge CONTRA Adapta-V Vertical installation, mounted pump shaft, standard motor

GEA Hilge CONTRA Adapta-tronic Horizontal installation, mounted pump shaft, standard motor with integrated frequency converter

GEA Hilge CONTRA Adapta V tronic Vertical installation, mounted pump shaft, standard motor with integrated frequency converter

Adapta-tronic pumps are equipped with an integrated frequency converter. Pumps in Adapta-SUPER design have a stainless steel motor shroud.

GEA Hilge CONTRA on Vertical Stand with Elbow

GEA Hilge CONTRA Adaptaon Combi Foot

GEA Hilge CONTRA Adapta on Combi FootGEA Hilge CONTRA Adapta on Cast Iron Foot

Page 34: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

34 ·

GEA GEA Hilge CONTRA Pumps

Overview GEA Hilge CONTRA I / II

Noise emissions

Measured values according to DIN EN ISO 3746 for pumpunits, measurement uncertainty 3 dB (A).

The noise emissions of a pump are significantly affected by the given application. The values given here therefore serve only as a guide. Please contact GEA Hilge for more detailed information.

Motor power [kW] Po

les

Lpfa [dB (A)]

Stages

1 2 3 4 5 6

0.75

2

61

1.1 61

1.5 61 62 63

2.2 62 62 64

3.0 64 65 66 72 74

4.0 70 74 76 76

5.5 73 75 76

Motor power [kW] Po

les

Lpfa [dB (A)]

Stages

2 3 4 5

4.0

2

68

5.5 70 72

7.5 71 72 74

11.0 75 76 76 78

15.0 77 77 79

18.5 78 80

5.5 82

Terminal box positionThis terminal box positions are possible for all pumps without shroud.

Possible terminal box positions

top right lefttop right left

GEA Hilge CONTRA I

GEA Hilge CONTRA II

Positioning of discharge

port and terminal box for

horizontal pumps

Positioning of discharge port and terminal box

Positioning of discharge

port and terminal box for

vertical pumps

12

3

9

12

9 3

12

9 3 12

93

Page 35: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 35

GEA GEA Hilge CONTRA Pumps

Features and benefits

Benefits

Process safety and optimal cleaning ability

Durable and robust

High flexibility

Duty-point-precise sizing, good NPSH value and high efficiency

Optimal adaptation to customer requirements and variable duty points

Low spare parts inventory

Service-friendliness

Extensive documentation and certificates

Features

EHEDG certified* and consistent implementation of hygienic design

Pump casing made from rolled steel with thick walls

Modular construction. Connections, mechanical seal, placements, etc. may be combined on an individual basis

Various combinations of impeller geometries and connection sizes

Motors with special voltages and frequencies, special coatings, special connections and sizes, drain ports and much more

Cover a large performance range with only two pump sizes

Easily interchangeable motors through the use of standard models. Service kits for all standard mechanical seals

Task-specific certificates for components

Overview GEA Hilge CONTRA I / II

* registerd for recertification

Page 36: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

36 ·

GEA GEA Hilge CONTRA Pumps

Product Range GEA Hilge CONTRA I / II

Motor data

Motor approval IE Class

Power [kW]

CEL China Energy

INMETRO Brazil

50 Hz 60 Hz PTC

0.75 • 3 2–3

1.1 • 3 2–3

1.5 • • 3 2–3

2.2 • • 3 2–3

3.0 • • 3 2–3 •

4.0 • • 3 2–3 •

5.5 • • 3 3 •

7.5 • • 3 2–3 •

11.0 • • 3 2–3 •

15.0 • • 3 2–3 •

18.5 • • 3 2–3 •

22.03 • • 3 2–3 •

Motors

GEA Hilge CONTRA I (2-pole)

P2 [kW] Frame size

0.75 80

1.1 80

1.5 90S

2.2 90L

3.0 100L

4.0 112M

5.5 132S1

GEA Hilge CONTRA II (2-pole)

Motor protectionThree-phase motors should be connected to a motor-protectivecircuit breaker.

All three-phase mains-operated standard motors can be connected to an external frequency converter. When a frequency converter is connected, the motor isolation is often overloaded, making the motor louder than during normal operation. In addition, large motors will be exposed to bearing currents caused by the frequency converter.

DesignThe motors are totally enclosed, fan-cooled standard motors with main dimensions according to IEC and DIN standards. Electrical tolerances according to IEC 34.

Pump rangeDesign – IEC 34-7

Horizontal installation

GEA Hilge CONTRAIM 3001 (IM B5)

IM 2001 (IM B35)

Relative air humidity: Max. 95 %Enclosure class: IP55Insulation class: F according to IEC 85Ambient temperature: Max. 40 °C (standard motor)

In humid locations, the lowest drain hole in the motor must beopened. In such cases, the motor enclosure class is IP44.

P2 [kW] Frame size

4.0 112M

5.5 132S1

7.5 132S

11.0 160M2

15.0 160L

18.5 160L

22.03 180M

3 only for Adapta

The following should be taken into account when operating afrequency converter:• In the event of special noise protection requirements, motor

noise can be reduced by using a dU/dt filter between the motor and the frequency converter. For noise-sensitive environments, we recommend using a sinus filter.

• The length of the cable between motor and frequency converter affects the motor load. For this reason, check whether the cable length corresponds to the specifications issued by the supplier of the frequency converter.

• For supply voltages between 500 and 690 V, either fit a dU/dt filter to reduce voltage peaks, or use a motor with reinforced insulation.

• For supply voltages of 690 V, use a motor with reinforced insulation and fit a dU/dt filter.

GEA Hilge CONTRA I/2 ADY 40 40 2.2 2

Pump Range

Size / Stage

Design

Nominal diameter of suction port (DN)

Nominal diameter of discharge port (DN)

Motor power (kW)

Number of poles

Type code

1 112M for Bloc Design

1 112M for Bloc Design, 2 132M for Bloc Design, 3 only for Adapta

Page 37: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 37

GEA GEA Hilge CONTRA Pumps

Connection Guide GEA Hilge CONTRA I / II

Selecting according to the application

The table below is intended as a general guide. Selection ofconnection often depends on on-site conditions.

Connection Application

Type

Beverages FoodLife science

and personal care

Industrialapplications

Cleaning

Bee

r

Win

e

Juic

e

Alc

oh

ol

Soft

dri

nk

s

Co

nfe

ctio

ner

y

Dai

ry p

rod

uct

s

Fryi

ng

oil

Syru

p

Pure

wat

er

Bio

tech

no

log

y p

rod

uct

s

Perf

um

es a

nd

loti

on

s

Glu

e an

d p

ain

t

Puri

fica

tio

n p

rod

uct

s

Ch

emic

al p

rod

uct

s

Ind

ust

rial

was

tew

ater

an

d ef

flu

x

Surf

ace

trea

tmen

t p

rod

uct

s

Bio

fuel

CIP

SIP

Cla

mp

s

DIN 32676/ Tri-Clamp/ASME

• • • • • •

Flan

ges

DIN 11864-2/ DIN 11853-2 flange • • • • • • • • • • • • • •

APV-FN1/APV/FN1 flange • • • • • • • • • •

DIN EN 1092-1 flange • • • • • • • • • • • • • • • •

Thre

ads

DIN 11864-1/ 11853-1 thread • • • • • • • • • • • • • •

DIN 11851 thread • • • • • • • • • • •

SMS thread • • • • • • • • • •

RJT thread • • • • • • • • • •

IDF thread • • • • • • • • • •

• Commonly used connections

Page 38: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

38 ·

GEA GEA Hilge CONTRA Pumps

Connection Guide GEA Hilge CONTRA I / II

Design

The following tables show the design of the different connection types.

Clamps

Applications Standard DesignDescription of the components

• Food Industry• Biotechnology / Pharmaceutical Industry

DIN 32676

0121a 0410 0121 0501

0121a: Clamp connection at pump casing0121: Clamp connection0410: Profile gasket0501: Clamp ring

Threads

Applications Standard DesignDescription of the components

Aseptic Thread

• Biotechnology / Pharmaceutical IndustryDIN 11864-1/

11853-1

0120a 0412 0120 0925

0120a: Threaded connection at pump casing0120: Threaded connection0412: O-ring0925: Grooved union nut

Thread

• Beverage Industry• Food Industry

DIN 11851

0120a: Threaded connection at pump casing0120: Threaded connection0411: Joint ring0925: Grooved union nut

• Beverage Industry• Food Industry

SMS (ISO 2037)

0120a: Threaded connection at pump casing0120: Threaded connection0411: Joint ring0925: Grooved union nut

• Beverage Industry• Food Industry

RJT (BS 4825-5)

0120a: Threaded connection at pump casing0120: Threaded connection0412: O-ring0925: Grooved union nut

• Beverage Industry• Food Industry

IDF (BS 4825-4)

0120a: Threaded connection at pump casing0120: Threaded connection0411: Joint ring0412: O-ring0925: Grooved union nut

Page 39: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 39

GEA GEA Hilge CONTRA Pumps

Connection Guide GEA Hilge CONTRA I / II

Applications Standard DesignDescription of the components

Aseptic Flange

• Biotechnology / Pharmaceutical Industry• Beverage Industry

DIN 11864-2/11853-2Form A

0122a: Flanged connection at pump casing0122: Flanged connection0412: O-ring0901: Hexagon head screw0920: Hexagon nut

Flange

• Food Industry• Beverage Industry

APV-FN1/ APV-FG1

0122a: Flanged connection at pump casing0122: Flanged connection0410: Profile gasket0901: Hexagon head screw0920:Hexagon nut

• Industrial ApplicationsDIN EN 1092-1

(fixed)

0122a: Flanged connection at pump casing0122: Flanged connection0400: Gasket0901: Hexagon head screw0920: Hexagon nut

Kremo Flange

• Industrial ApplicationsDIN EN 1092-1

(loose)

0122a: Flanged connection at pump casing0122: Flanged connection0400: Gasket0901: Hexagon head screw0920: Hexagon nut

Flanges

Page 40: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

40 ·

GEA GEA Hilge CONTRA Pumps

Seals GEA Hilge CONTRA I / II

In order to ensure correct operation (depending on the application and the medium), single or double mechanical seals can be supplied. The single mechanical seal is an inboard seal. Double mechanical seals are available as tandem or back-to-back execution. All seals are optimally placed inside the pump.

Mechanical seals

The operating range of the seal depends on the liquid, the type of seal, the operating pressure and the liquid temperature.

VersionMaterial pairsstationary seat/seal face/O-rings

Max. pressure Max. temperature

Open spring

Carbon / stainless steel / EPDMCarbon / stainless steel / FKMSilicon carbide / silicon carbide / EPDMSilicon carbide / silicon carbide / FKM

10 bar –20 to 80 °C

Encapsulated spring

Carbon / stainless steel / EPDM Silicon carbide / silicon carbide / EPDMSilicon carbide / silicon carbide / FFKMSilicon carbide / silicon carbide / FKM

25 bar –20 to 100 °C

Special seals available in different materials up to 25 bar.

This ensures efficient lubrication and cooling of the mechanical seal, while also ensuring CIP (Cleaning In Place) and SIP (Sterilisation In Place) capability. The standard material for the mechanical seals are carbon/stainless steel or SiC/SiC with EPDM or FKM (Viton) elastomers.

The seal types described below are standard seal types; other seals are available on request.

Page 41: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 41

GEA GEA Hilge CONTRA Pumps

Seals GEA Hilge CONTRA I / II

Mechanical seal arrangements

Arrangement Design Components Seal characteristics

Single mechanical seal with encapsulated spring

0433.00: Mechanical seal a: Contact surface impeller side

• Encapsulated spring• Easy to clean• Optimal position inside the pump• Bidirectional

Double mechanical seal, back-to-back

0433.00

0471.00 0516.00 0433.01

0433.00: Mechanical seal, product side0433.01: Mechanical seal, atmosphere side0471.00: Seal cover0516.00: Locating ring

• Back-to-back arrangement• Overpressure in barrier fluid space

(seal cartridge)• No product leakage into the

surrounding atmosphere• No dry running• Mechanical seals are lubricated

and cooled

Double mechanical seal, tandem

0433.00

0433.01

a

0516.00

0433.00: Mechanical seal, product side0433.01: Mechanical seal, atmosphere side0516.00: Locating ringa: Contact surface impeller side

• Tandem arrangement• Open conical spring• Pressure-less flushing (seal cartridge)• No dry running• Mechanical seals are lubricated

and cooled

Double mechanical seal, tandem

a

0516.00 0433.010471.00

0433.00

0433.00: Mechanical seal, product side0433.01: Mechanical seal, atmosphere side0471.00: Seal cover0516.00: Locating ringa: Contact surface impeller side

• Tandem arrangement• Product-side spring encapsulated• Pressure-less flushing (seal cartridge)• No dry running• Mechanical seals are lubricated

and cooled

Page 42: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

42 ·

GEA GEA Hilge CONTRA Pumps

Installation GEA Hilge CONTRA I / II

Horizontal installation

Horizontal installation • Pumps fitted with motors up to and including 4 kW require a

300 mm clearance behind the motor.• Pumps fitted with motors of 5.5 kW and up require at least a

1 meter clearance above the motor and 300 mm behind it to allow the use of lifting equipment.

Mechanical installation Space requirements

300 mm

1 m

300 mm

> 5.5 kW

0.55–4 kW

Installation GEA Hilge CONTRA Adapta

GEA Hilge CONTRAThe pumps of the GEA Hilge CONTRA Adapta series can be installed horizontally and vertically.

When installing vertically, always install the motor facing upwards.

The pumps must be installed in such a way that strain from the pipework is not transferred to the pump casing. When installed outdoors, the motor must be provided with a suitable cover to avoid condensation on the electronic components and to protect pump and motor against the direct effects of the elements.

Vertical installation

Vertical installation • Pumps fitted with motors up to and including 4 kW require a

300 mm clearance above the motor.• Pumps fitted with motors of 5.5 kW and up require at least a

1 meter clearance above the motor to allow the use of lifting equipment.

1 m300 mm

> 5.5 kW0.55–4 kW

Page 43: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 43

GEA GEA Hilge CONTRA Pumps

Installation GEA Hilge CONTRA I / II

Foundation Vibration dampening is best achieved by installing the pumps on a plane and rigid concrete foundation.

As a guideline, the weight of the concrete foundation should be 1.5 times the pump weight.

Vibration dampersTo prevent vibrations from being transmitted to the building, we recommend that you isolate the pump foundation from buildings by means of vibration dampers.

The selection of the correct vibration dampers requires the following data:• Forces that will be transmitted through the vibration dampers• Motor speed, taking speed control into account as needed• Required dampening in % (suggested value is 70 %)

The right damper varies from installation to installation, and the wrong damper may increase the vibration level. Vibration dampers should therefore be sized by the supplier.

If the pump is installed on a pedestal with vibration dampers, expansion joints must always be fitted on the pipeline connections. This is important to prevent the pump from “hanging” in the connections.

Install expansion joints in order to:• Absorb expansion/contractions in the pipework caused by

variable liquid temperatures• Reduce mechanical strains that occur in connection with

pressure surges in the plant• Isolate mechanical structure-borne noise in the pipework

(only rubber bellows expansion joints)

Note: Do not install expansion joints to compensate for inaccuracies in the pipework such as center displacement of flanges.

Fit expansion joints at a distance of at least 1 to 1.5 times the nominal flange diameter away from the pump on the suction as well as on the discharge side. This will prevent the development of turbulence in the expansion joints, resulting in better suction conditions and a minimum pressure loss on the discharge side.

We always recommend expansion joints with limiting rods for flanges larger than DN 100.

The pipes should be anchored so that they do not stress theexpansion joints and the pump. Follow the supplier’s instructions and pass them on to advisers or pipe installers.

In order to achieve optimum operation and minimum noise and vibration, consider vibration dampening of the pump. Generally, always consider this for pumps with motors above 11 kW. Smaller motors, however, may also cause undesirable noise and vibration.

Noise and vibration are generated by the rotation in the motor and pump and by the flow in the pipework and fittings. The effect on the environment is subjective and depends on correct installation and the state of the remaining system.

Elimination of noise and vibrations Expansion joints

Example of a pump foundation

Expansion joints

Concrete foundation

Vibration dampers

Page 44: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

44 ·

GEA GEA Hilge CONTRA Pumps

Media Guide GEA Hilge CONTRA I / II

The values for density and viscosity given here are ratios and can deviate in practice.

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single Tandem

Altbier

< 100 1,000 1aeE (up to 10 bar), aiH (from 10 bar)

Beer

Beer mix

Berliner Weisse

Bock beer

Craft beer

Export beer

Full beer (Vollbier)

Green beer

Herb beer

Lager

Light beer

Martzen (Märzen)

Non-alcoholic beer

Pils

Pilsener

Ringed (Kräusen)

Wheat beer

Cold wort< 40 < 1,050 < 5

aeE (up to 10 bar), aiH (from 10 bar)

– Original wort

Hop extract (dissolved)

< 100 < 1,050 < 5 – kiE/aeELees

Mash (beer)

Lauter wort 40–90 < 1,050 < 5 – kiE/aeE

Hot wort 40–115 < 1,050 < 5 – kiE/aeE

Crop yeast

< 20 < 1,050 < 100 aeE – Pitching yeast

Yeast

Enzymes (watery dissolution) < 60 < 1,050 < 5 aeE –

Lactic acid, con. < 50 % (C3H6O3) < 100 < 1,100 < 5kiV (up to 16 bar), kiI ( up to 25 bar)

Lactic acid, con. > 50 % (C3H6O3) < 100 < 1,210 < 5kiV (up to 16 bar), kiI ( up to 25 bar)

Application beer

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single Tandem

Iced water −4 to +3 < 1,000 1kiE (up to 10 bar), kiH (from 10 bar)

Cold water

< 110 < 1,000 1aeE (up to 10 bar), aiH (from 10 bar)

Demineralised water (Not for sterile applications)

Drinking water

Flushing water

Hot water

Mineral water

Process water

Service water

Water

Application water

Page 45: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 45

GEA GEA Hilge CONTRA Pumps

Media Guide GEA Hilge CONTRA I / II

* aeE: carbon/stainless steel/EPDM, aeV: carbon/stainless steel/Viton, aiH: carbon/SIC/EPDM (USP-Class VI), kiE: SIC/SIC/EPDM, kiH: SiC/SiC/EPDM (USP-Class VI), kil: SIC/SIC/Viton (USP Class VI), kiV: SIC/SIC/Viton, WDR: lip seal. The elastomer of the static seals equals the elastomer of the mechanical seals.

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single Tandem

Champagne

< 35 < 1,000 1aeE (up to 10 bar), aiH (from 10 bar)

Cherry wine

Cider

Cidre

Dry sparkling wine

Fruit wine

Prosecco

Red wine

Rosé wine

Sparkling wine

Strawberry wine

White wine

Wine

Young wine

Dessert wine

< 35 < 1,050 15aeE (up to 10 bar), aiH (from 10 bar)

–Dessert wine, late-harvest wine

Drape must (w/o. particles)

Ice wine

Wine lees< 35 < 1,050 100

aeE (up to 10 bar), aiH (from 10 bar)

–Wine yeast

Mash (wine) < 35 < 1,050 5aeE (up to 10 bar), aiH (from 10 bar)

Application wine / sparkling wine

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single TandemEncapsulated seal

for vacuum application

Coffee < 125 1,000 1 aeE –

Coffee extract < 80–100 < 1,200 < 250 – kiV/aeV x

Tea < 125 1,000 1 aeE –

Fruit tea / flavored tea < 125 1,000 1 aeE –

Cocoa drink < 40 1,020 < 10 aeE –

Application coffee / tea / cocoa

Page 46: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

46 ·

GEA GEA Hilge CONTRA Pumps

Media Guide GEA Hilge CONTRA I / II

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single Tandem

Buttermilk

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

UHT milk

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Yoghurt milk

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Kefir

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Cheese milk

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Skimmed milk

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Skimmed milk concentrate

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Milk

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Milk concentrate

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Lactic culture

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Milk mix

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Whey

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Raw milk

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Pre-stirred yoghurt

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Sour milk

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Application milk

Page 47: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 47

GEA GEA Hilge CONTRA Pumps

Media Guide GEA Hilge CONTRA I / II

* aeE: carbon/stainless steel/EPDM, aeV: carbon/stainless steel/Viton, aiH: carbon/SIC/EPDM (USP-Class VI), aiI: carbon/SIC/Viton (USP-Class VI), kiE: SIC/SIC/EPDM, WDR: lip seal. The elastomer of the static seals equals the elastomer of the mechanical seals.

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single Tandem

Sour cream with thickening agents

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Full cream milk

< 55 < 1,050 < 10aeE (up to 10 bar), aiH (from 10 bar)

> 55 – < 100 < 1,050 < 5 –aeE/aeE (up to 10 bar), aiH/aeE (from 10 bar)

Coffee cream

< 55 < 1,100 < 40aeV (up to 10 bar),

ail (from 10 bar)–

> 55 – < 100 < 1,100 < 20 –aeV/aeV (up to 10 bar),aiI/aeV (from 10 bar)

Whipping cream

< 55 < 1,100 < 40aeV (up to 10 bar),

ail (from 10 bar)–

> 55 – < 100 < 1,100 < 20 –aeV/aeV (up to 10 bar),aiI/aeV (from 10 bar)

Sour cream

< 55 < 1,100 < 40aeV (up to 10 bar),

ail (from 10 bar)–

> 55 – < 100 < 1,100 < 20 –aeV/aeV (up to 10 bar),aiI/aeV (from 10 bar)

Cream

< 55 < 1,100 < 40aeV (up to 10 bar),

ail (from 10 bar)–

> 55 – < 100 < 1,100 < 20 –aeV/aeV (up to 10 bar),aiI/aeV (from 10 bar)

Condensed milk

< 55 < 1,100 < 40aeV (up to 10 bar),

ail (from 10 bar)–

> 55 – < 100 < 1,100 < 20 –aeV/aeV (up to 10 bar),aiI/aeV (from 10 bar)

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single Tandem

Soy sauce5–95 1,250 25 kiE –

95.1–125 1,250 25 – kiE/aeE

Cider vinegar

60 1,020 1 aeE –Herb-flavoured vinegar

Vinegar

Wine vinegar

Vinegar essence 60 1,050 1 aeV –

Application vinegar / sauces / marinade

Page 48: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

48 ·

GEA GEA Hilge CONTRA Pumps

Media Guide GEA Hilge CONTRA I / II

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single Tandem Encapsulated seal

Apple juice

< 70 1,040 < 50 aeE –

< 70 1,040 < 50 aeE – x

< 70 1,040 < 50 kiE – x

> 70 – < 95 1,040 < 10 – kiE/aeE

> 70 – < 95 1,040 < 10 – kiE/aeE x

Apricot-mango juice

< 70 1,040 < 50 aeE –

< 70 1,040 < 50 aeE – x

< 70 1,040 < 50 kiE – x

> 70 – < 95 1,040 < 10 – kiE/aeE

> 70 – < 95 1,040 < 10 – kiE/aeE x

Cherry juice

< 70 1,040 < 50 aeE –

< 70 1,040 < 50 aeE – x

< 70 1,040 < 50 kiE – x

> 70 – < 95 1,040 < 10 – kiE/aeE

> 70 – < 95 1,040 < 10 – kiE/aeE x

Cola< 100 1,040 < 5 aeE –

< 100 1,040 < 5 aeE –

Concentrated lemon juice, without pulp and granules

< 70 1,040 25 kiV –

Cranberry juice

< 70 1,040 < 50 aeE –

< 70 1,040 < 50 aeE – x

< 70 1,040 < 50 kiE – x

> 70 – < 95 1,040 < 10 – kiE/aeE

> 70 – < 95 1,040 < 10 – kiE/aeE x

Multivitamin juice < 70 1,040 < 50 kiE – x

Fruit juice, with granules < 70 1,040 < 50 kiE – x

Fruit juice, with pulp 1,040 < 50 aeE – x

Fruit juice, with pulp and with granules

> 70 – < 95 1,040 < 10 – kiE/aeE x

Fruit juice, without pulp< 70 1,040 < 50 aeE –

> 70 – < 95 1,040 < 10 – kiE/aeE

Grape juice

< 70 1,040 < 50 aeE –

< 70 1,040 < 50 aeE – x

< 70 1,040 < 50 kiE – x

> 70 – < 95 1,040 < 10 – kiE/aeE

> 70 – < 95 1,040 < 10 – kiE/aeE x

Iced tea < 100 1,040 < 5 aeE –

Lemon juice, with pulp and granules

< 70 1,040 25 kiV – x

Lemon juice, without pulp and granules

< 70 1,040 25 aeV –

Lemonade< 100 1,040 < 5 aeE –

< 100 1,040 < 5 aeE –

Mineral water< 100 1,040 < 5 aeE –

< 100 1,040 < 5 aeE –

Multivitamin juice

< 70 1,040 < 50 aeE –

< 70 1,040 < 50 aeE – x

> 70 – < 95 1,040 < 10 – kiE/aeE

> 70 – < 95 1,040 < 10 – kiE/aeE x

Orange juice

< 70 1,040 < 50 aeE –

< 70 1,040 < 50 aeE – x

< 70 1,040 < 50 kiE – x

> 70 – < 95 1,040 < 10 – kiE/aeE

> 70 – < 95 1,040 < 10 – kiE/aeE x

Peach- / passion fruit juice

< 70 1,040 < 50 aeE –

< 70 1,040 < 50 aeE – x

< 70 1,040 < 50 kiE – x

> 70 – < 95 1,040 < 10 – kiE/aeE

> 70 – < 95 1,040 < 10 – kiE/aeE x

Application non-alcoholic drink

Page 49: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 49

GEA GEA Hilge CONTRA Pumps

Media Guide GEA Hilge CONTRA I / II

* aeE: carbon/stainless steel/EPDM, aeV: carbon/stainless steel/Viton, aiH: carbon/SIC/EPDM (USP-Class VI), kiE: SIC/SIC/EPDM, kiH: SiC/SiC/EPDM (USP-Class VI), kiV: SIC/SIC/Viton, WDR: lip sea. The elastomer of the static seals equals the elastomer of the mechanical seals.

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single Tandem Encapsulated seal

Raspberry- / Strawberry juice

< 70 1,040 < 50 aeE –

< 70 1,040 < 50 aeE – x

< 70 1,040 < 50 kiE – x

> 70 – < 95 1,040 < 10 – kiE/aeE

> 70 – < 95 1,040 < 10 – kiE/aeE x

Vegetable juice, with pulp and granules

< 70 1,050 < 50 kiV – x

> 70 – < 95 1,050 < 10 – kiV/aeV x

Vegetable juice, without pulp and granules

< 70 1,050 < 50 aeV –

> 70 – < 95 1,050 < 10 – kiV/aeV

Mechanical seal* material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Concentration [Brix]

Single Tandem

Concentrated fruit juice

5–90 1,150

rela

ted

to

tem

per

atu

re

to 25°aeE (up to 10 bar), aiH (from 10 bar)

5–40 1,200 26–49°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,200 26–49° – aeE/aeE

15–40 1,230 50°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,230 50° – aeE/aeE

15–40 1,260 55°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,260 55° – aeE/aeE

15–40 1,290 60°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,290 60° – aeE/aeE

15–40 1,320 65°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,320 65° – aeE/aeE

20–40 1,350 70°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,350 70° – aeE/aeE

Application concentrated fruit juice

Page 50: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

50 ·

GEA GEA Hilge CONTRA Pumps

Media Guide GEA Hilge CONTRA I / II

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single Tandem

Cocoa butter

10–30 940 < 80 aeV –

Coconut oil / copra oil

Corn oil

Cotton seed oil

Linseed oil

Olive oil

Palm oil

Peanut oil

Pumpkin seed oil

30.1–125 920 < 40 aeV –

Rape oil / rapeseed oil

Safflower oil

Sesame oil

Soy oil / soy bean oil

Sunflower oil

Walnut oil

Wheat germ oil

Chip fat < 170 900 10 aeV –

Butter oil (liquid) > 45–120 860 45 aeV –

Lard (liquid) > 45–120 860 45 aeV –

Liquid butter > 35–120 860 45 aeV –

Fish oil 10–125 950 < 100 aeV –

Whale oil 10–125 950 < 100 aeV –

Cod liver (cod-liver oil) 10–125 950 < 100 aeV –

Mineral oil

10–100 aeV –Motor oil

Petroleum

Derv10–100 850 < 15 aeV –

Diesel oil

Oil-in-water emulsion 0–100 1,000 < 50 aeV –

Application oil

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Concentration [%]

Single Tandem

CIP liquid (concentration approx. 5 %)

< 100 1,050 < 5 < 5aeE (up to 10 bar), aiH (from 10 bar)

Application cleaning in place CIP

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Concentration [%]

Single Tandem

Spirits

40 < 1,000 < 5aeE (up to 10 bar), aiH (from 10 bar)

< 50 < 1,150 < 150 – kiE/aeE

< 100 < 1,150 < 100 – kiE/aeE

< 78 < 1,000 1 < 10aeE (up to 10 bar), aiH (from 10 bar)

< 78 900 1 < 50aeE (up to 10 bar), aiH (from 10 bar)

< 78 800 1 < 98aeE (up to 10 bar), aiH (from 10 bar)

Application spirits

Page 51: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 51

GEA GEA Hilge CONTRA Pumps

Media Guide GEA Hilge CONTRA I / II

* aeE: carbon/stainless steel/EPDM, aeV: carbon/stainless steel/Viton, aiH: carbon/SIC/EPDM (USP-Class VI), kiE: SIC/SIC/EPDM, kiH: SiC/SiC/EPDM (USP-Class VI), WDR: lip seal. The elastomer of the static seals equals the elastomer of the mechanical seals.

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Concentration [Brix]

Single Tandem

Sugar syrupwithout crystals

5–90 1,150

rela

ted

to

tem

per

atu

re

to 25°aeE (up to 10 bar), aiH (from 10 bar)

5–40 1,200 26–49°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,200 26–49° – aeE/aeE

15–40 1,230 50°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,230 50° – aeE/aeE

15–40 1,260 55°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,260 55° – aeE/aeE

15–40 1,290 60°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,290 60° – aeE/aeE

15–40 1,320 65°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,320 65° – aeE/aeE

20–40 1,350 70°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,350 70° – aeE/aeE

20–40 1,360 72,7°aeE (up to 10 bar), aiH (from 10 bar)

40.1–90 1,360 72,7° – aeE/aeE

5–90 1,150 to 25°kiE (up to 10 bar), kiH (10 – 16 bar)

5–40 1,200 26–49°kiE (up to 10 bar), kiH (10 – 16 bar)

40.1–90 1,200 26–49° – kiE/aeE

15–40 1,230 50°kiE (up to 10 bar), kiH (10 – 16 bar)

40.1–90 1,230 50° – kiE/aeE

15–40 1,260 55°kiE (up to 10 bar), kiH (10 – 16 bar)

40.1–90 1,260 55° – kiE/aeE

15–40 1,290 60°kiE (up to 10 bar), kiH (10 – 16 bar)

40.1–90 1,290 60° – kiE/aeE

15–40 1,320 65°kiE (up to 10 bar), kiH (10 – 16 bar)

40.1–90 1,320 65° – kiE/aeE

20–40 1,350 70°kiE (up to 10 bar), kiH (10 – 16 bar)

40.1–90 1,350 70° – kiE/aeE

Application sugar syrup

Page 52: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

52 ·

GEA GEA Hilge CONTRA Pumps

Media Guide GEA Hilge CONTRA I / II

Application chemicals

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Concentration [%]

Single Tandem

Caustic soda (NaOH)

< 60 = Concentration < 15 kiE –

< 60 = Concentration > 15 – < 50 – kiE/aeE

> 60 – < 101 = Concentration < 12 kiE –

> 60 – < 101 = Concentration < 12 – < 50 – kiE/aeE

Peracetic / peroxyacetic (C24O3)< 60 < 1,020 < 1 < 5 kiV –

< 60 < 1,060 < 5 > 5.1 – < 15 kiK –

Phosphoric acid (H3PO4)

< 40 1 % = 1,0045 % = 1,026

10 % = 1,05320 % = 1,11435 % = 1,21645 % = 1,293

< 5 < 15 kiV –

> 40 – < 85 < 5 < 15 – kiV/aeV

< 85 < 5 > 15 – < 45 – kiV/aeV

Nitric acid (HNO3)

0–201 % = 1,00410 % = 1,05520 % = 1,11530 % = 1,18040 % = 1,245

5 0–10 kiV –

20.1–40 5 0–10 – kiV/aeV

0–40 5 10.1–20 – kiV/aeV

40.1–85 5 0–20 – kiV/aeV

0–85 5 20.1–40 – kiV/aeV

Sulfuric acid (H2SO4)< 20 < 1,1 < 25 < 12 – kiV/aeV

< 70 < 1,08 < 20 < 12 – kiK/aeV

High test peroxide (H2O2)Hydrogen peroxide

< 90 < 1,050 2 2–3 aeV –

< 90 < 1,150 2 < 40 kiV –

< 90 < 1,300 2 < 60 kiV –

< 60 < 1,450 2 < 100 – kiV/aeV

Brine solutionCommon salt solutionSodium chloride (NaCl)

< 30 < 1,050 < 5 < 5 aeE –30.1–40 < 1,050 < 5 < 5 kiE –

< 40 < 1,080 < 5 5.1–10 kiE –< 40 < 1,200 < 25 10.1–25 – kiE/aeE

Curing brine (butchery) < 40 1,200 < 300 < 20 kiE –

Salting brine (cheese dairy) < 40 1,300 < 60 20–30 – kiE/aeE

Ammonia/ammoniac (NH3) < 40 800 < 5 – aeE/aeE

Caustic potash (KOH)Potassium hydroxide

< 60 < 1,100 < 5 < 10 kiE –

< 60 < 1,200 < 5 < 20 kiE –

GlycerolPropanetriol

80 < 1,100 < 5 0–40 aeV –80 < 1,160 < 20 40.1–60 aeV –80 < 1,200 < 50 60.1–75 aeV –80 < 1,220 < 100 75.1–85 aeV –

Propylene-glycol (C3H8O2)

0–80 1,010 < 5 1–20 kiV –

−5–80 1,020 < 20 20.1–50 kiV –

−10–80 1,040 < 150 50.1–75 kiV –

−10–0 1,060 < 255 75.1–100 kiV –

0.1–80 1,050 < 150 75.1–100 kiV –

EthanediolEthylene-glycol (C2H6O2)

0–80 1,030 < 5 1–20 kiE –

−5–80 1,060 < 20 20.1–50 kiE

−10–80 1,090 < 40 50.1–75 kiE –

−10–0 1,120 < 100 75.1–100 kiE

0.1–80 1,110 < 65 75.1–100 kiE –

Citric acid (C6H8O7)Natural citric acid

5–801 % = 1,00510 % = 1,020

< 15 <10 kiV –

5–80

10.1 % = 1,02020 % = 1,05030 % = 1,10050 % = 1,260

< 15 10.1–50 kiV –

Acetic acid (C2H4O2)5–80 1,010 1 < 10 aeE –

5–100 1,050 1 10.1–100 – aeK/aeE

Page 53: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 53

GEA GEA Hilge CONTRA Pumps

Media Guide GEA Hilge CONTRA I / II

* aeE: carbon/stainless steel/EPDM, aeK: carbon/stainless steel/FFKM, aeV: carbon/stainless steel/Viton, kiE: SIC/SIC/EPDM, kiH: SiC/SiC/EPDM (USP-Class VI), kiV: SIC/SIC/Viton, ooH: SIC/SIC/EPDM (USP-Class VI). The elastomer of the static seals equals the elastomer of the mechanical seals.

Application waste water

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single Tandem

Dirty water

1,000 1 kiV –

Laboratory waste water

Sewage < 80

Waste water, without solids (not abrasive), pH < 7

Dirty water

< 80 1,000 1 kiE –

Laboratory waste water

Sewage

Waste water, without solids (not abrasive), pH < 7

Landfill seepage water,not ozoniferous,chloride content max. 350mg/l

< 50 1,000 1 kiV –

Landfill seepage water,not ozoniferous,no chloride content

< 50 1,000 1 kiV –

Landfill seepage water,ozoniferous, max. 300 ppB,chloride content max. 350mg/l

< 50 1,000 1 kiK –

Landfill seepage water,ozoniferous, max. 300 ppB,no chloride content

< 50 1,000 1 kiK –

Activated sludge < 60 1,000 1 kiV –

Application pharma

Mechanical seal*material product side / atmospheric side

SubgroupTemperature

[°C]Density [kg/m³]

Viscosity [mPas]

Single Tandem Encapsulated seal

Purified water (PW) 0–125 1,000 1 kiH –

Highly purified water (HPW)

0–125 1,000 1 kiH-C1/ooH-C1 –Ultra purified water (UPW)

Water for injection (WFI)

Page 54: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

54 ·

GEA

Pump Selection Matrix

Catalogs Hygienic Valve Technology

Catalogs Hygienic Pump Technology

Catalog Aseptic Valve Technology

Catalog Cleaning Technology

GEA SMARTPUMPS

GEA Hilge TP

GEA Hilge TPS

GEA Hilge DURIETTA

GEA VARIPUMPS

GEA Hilge HYGIA

GEA Hilge MAXA

GEA Hilge SIPLA

GEA Hilge CONTRA

GEA Hilge NOVALOBE

Page 55: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 55 GEA Hilge CONTRA I / II

GEA Hilge CONTRA Pumps

GEA Hilge CONTRA I

GEA Hilge CONTRA II

GEA Hilge CONTRASingle- and Multi-Stage

pumps

1

2

Page 56: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

56 ·

GEA GEA Hilge CONTRA Pumps

Connection Dimensions GEA Hilge CONTRA I

Nominal width

Connection type

1-stage 2-stage

DIN 25/25 32/25 32/32 40/25 40/32 40/40 25/25 32/25 32/32 40/25 40/32 40/40

ISO 33.7/33.7

42.4/33.7

42.4/42.4

48.3/33.7

48.3/42.4

48.3/48.3

33.7/33.7

42.4/33.7

42.4/42.4

48.3/33.7

48.3/42.4

48.3/48.3

OD 1"/1" 1¼"/1" 1¼"/1¼" 1½"/1" 1½"/1¼" 1½"/1½" 1"/1" 1¼"/1" 1¼"/1¼" 1½"/1" 1½"/1¼" 1½"/1½"

Threaded connectionDIN 11851(DIN)

a1 117.0 120.0 123.0 121.0 124.0 127.0 143.0 146.0 149.0 147.0 150.0 153.0 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 160.0 160.0 160.0 160.0 160.0 160.0 160.0 160.0 160.0 160.0 160.0 160.0 e5 106.0 114.0 114.0 120.0 120.0 120.0 106.0 114.0 114.0 120.0 120.0 120.0 h3 119.0 127.0 127.0 133.0 133.0 133.0 119.0 127.0 127.0 133.0 133.0 133.0

Threaded connectionDIN 11864-1 / DIN 11853-1Pipe range A (DIN)*

a1 114.0 118.0 121.0 119.0 122.0 125.0 140.0 144.0 147.0 145.0 148.0 151.0 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 157.0 157.0 158.0 157.0 158.0 158.0 157.0 157.0 158.0 157.0 158.0 158.0 e5 106.0 113.0 113.0 119.0 119.0 119.0 106.0 113.0 113.0 119.0 119.0 119.0 h3 116.0 125.0 125.0 131.0 131.0 131.0 116.0 125.0 125.0 131.0 131.0 131.0

Threaded connectionDIN 11864-1 / DIN 11853-1Pipe range B (ISO)**

a1 121.0 122.0 125.0 122.0 125.0

(E)

147.0 148.0 151.0 148.0 151.0

(E)f2 4.0 4.0 7.0 4.0 7.0 4.0 4.0 7.0 4.0 7.0 h2 157.0 157.0 159.0 157.0 159.0 157.0 157.0 159.0 157.0 159.0 e5 97.0 106.5 106.5 120.0 120.0 97.0 106.5 106.5 120.0 120.0 h3 108.0 118.5 118.5 128.0 128.0 108.0 118.5 118.5 128.0 128.0

Threaded connection SMS International(OD)

a1 103.0 106.0 109.0 108.0 111.0 114.0 129.0 106.0 109.0 134.0 137.0 140.0 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 150.0 150.0 146.0 150.0 146.0 147.0 150.0 150.0 146.0 150.0 146.0 147.0 e5 (A) (A)h3

Threaded connection BS4825-RJT(OD)

a1 109.5 (N/A) (N/A) 109.5 (N/A) 115.5 135.5 (N/A) (N/A) 135.5 (N/A) 141.5f2 1.0 (N/A) (N/A) 1.0 (N/A) 7.0 1.0 (N/A) (N/A) 1.0 (N/A) 7.0h2 152.5 (N/A) (N/A) 152.5 (N/A) 148.5 152.5 (N/A) (N/A) 152.5 (N/A) 148.5e5 (A) (A)h3

Threaded connection ISO2853-IDF(OD)

a1 (A) (N/A) (N/A) (A) (N/A) 112.5 (A) (N/A) (N/A) (A) (N/A) 138.5f2 (A) (N/A) (N/A) (A) (N/A) 7.0 (A) (N/A) (N/A) (A) (N/A) 7.0h2 (A) (N/A) (N/A) (A) (N/A) 145.5 (A) (N/A) (N/A) (A) (N/A) 145.5e5 (A) (A)h3

ClampDIN 32676 Pipe range A (DIN)*

a1 109.5 109.5 112.5 109.5 112.5 115.5 135.5 135.5 138.5 135.5 138.5 141.5 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 152.5 152.5 149.5 152.5 149.5 148.5 152.5 152.5 149.5 152.5 149.5 148.5 e5 113.5 118.5 118.5 123.5 123.5 123.5 113.5 118.5 118.5 123.5 123.5 123.5 h3 111.5 116.5 116.5 121.5 121.5 121.5 111.5 116.5 116.5 121.5 121.5 121.5

ClampDIN 32676 Pipe range B (ISO)**

a1 112.5 112.5 115.5 112.5 115.5

(E)

138.5 138.5 141.5 138.5 141.5

(E)f2 4.0 4.0 7.0 4.0 7.0 4.0 4.0 7.0 4.0 7.0 h2 149.5 149.5 148.5 149.5 148.5 149.5 149.5 148.5 149.5 148.5 e5 101.5 111.0 111.0 120.5 120.5 101.5 111.0 111.0 120.5 120.5 h3 99.5 109.0 109.0 118.5 118.5 99.5 109.0 109.0 118.5 118.5

ClampDIN 32676 Pipe range C (OD)***

a1 109.5 (N/A) (N/A) 109.5 (N/A) 115.5 135.5 (N/A) (N/A) 135.5 (N/A) 141.5f2 1.0 (N/A) (N/A) 1.0 (N/A) 7.0 1.0 (N/A) (N/A) 1.0 (N/A) 7.0h2 152.5 (N/A) (N/A) 152.5 (N/A) 163.0 152.5 (N/A) (N/A) 152.5 (N/A) 163.0e5 99.7 (N/A) (N/A) 118.8 (N/A) 118.8 99.7 (N/A) (N/A) 118.8 (N/A) 118.8h3 97.7 (N/A) (N/A) 116.8 (N/A) 116.8 97.7 (N/A) (N/A) 116.8 (N/A) 116.8

Grooved flangeDIN 11864-2 / DIN 11853-1 Pipe range A (DIN)*

a1 111.7 111.7 114.7 111.7 114.7 117.7 137.7 137.7 140.7 137.7 140.7 143.7f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0h2 154.7 154.7 151.7 154.7 151.7 150.7 154.7 154.7 151.7 154.7 151.7 150.7e5 112.5 117.5 117.5 122.5 122.5 122.5 112.5 117.5 117.5 122.5 122.5 122.5h3 113.7 118.7 118.7 123.7 123.7 123.7 113.7 118.7 118.7 123.7 123.7 123.7

Grooved flangeDIN 11864-2 / DIN 11853-1 Pipe range A (DIN)*

a1 114.7 114.7 117.7 114.7 117.7

(E)

140.7 140.7 143.7 140.7 143.7

(E)f2 4.0 4.0 7.0 4.0 7.0 4.0 4.0 7.0 4.0 7.0 h2 150.7 150.7 150.7 150.7 150.7 150.7 150.7 150.7 150.7 150.7 e5 100.5 110.0 110.0 119.5 119.5 100.5 110.0 110.0 119.5 119.5 h3 101.7 111.2 111.2 120.7 120.7 101.7 111.2 111.2 120.7 120.7

Flange EN1092-1 PN10 Kremo(ISO)

a1 101.0 101.0 104.0 101.0 104.0 107.0 127.0 127.0 130.0 127.0 130.0 133.0 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 144.0 144.0 141.0 144.0 141.0 140.0 144.0 144.0 141.0 144.0 141.0 140.0 e5 (A) (A)h3

Flange connectionAPV-FG / 3.1-PN10(DIN)

a1 112.0 (N/A) (N/A) 112.0 (N/A) 118.0 138.0 (N/A) (N/A) 138.0 (N/A) 144.0f2 1.0 (N/A) (N/A) 1.0 (N/A) 7.0 1.0 (N/A) (N/A) 1.0 (N/A) 7.0h2 155.0 (N/A) (N/A) 155.0 (N/A) 151.0 155.0 (N/A) (N/A) 155.0 (N/A) 151.0e5 (A) (A)h3

Flange connectionAPV-FG / 3.1-PN25(DIN)

a1 (A) (N/A) (N/A) (A) (N/A) 110.0 (A) (N/A) (N/A) (A) (N/A) 136.0f2 (A) (N/A) (N/A) (A) (N/A) 7.0 (A) (N/A) (N/A) (A) (N/A) 7.0h2 (A) (N/A) (N/A) (A) (N/A) 143.0 (A) (N/A) (N/A) (A) (N/A) 143.0e5 (A) (A)h3

Tolerances according to DIN EN 735 Connection dimensions for centrifugal pumps. * For pipes according to DIN 11866 series A** For pipes according to DIN 11866 series B*** For pipes according to DIN 11866 series C (pipe dimensions according to ASME BPE)(A) On request(E) On request. Not fully drainable in vertical position(N/A) Not Available

Page 57: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 57

GEA GEA Hilge CONTRA Pumps

Connection Dimensions GEA Hilge CONTRA I

Nominal width

Connection type

3-stage 4-stage

DIN 25/25 32/25 32/32 40/25 40/32 40/40 25/25 32/25 32/32 40/25 40/32 40/40

ISO 33.7/33.7

42.4/33.7

42.4/42.4

48.3/33.7

48.3/42.4

48.3/48.3

33.7/33.7

42.4/33.7

42.4/42.4

48.3/33.7

48.3/42.4

48.3/48.3

OD 1"/1" 1¼"/1" 1¼"/1¼" 1½"/1" 1½"/1¼" 1½"/1½" 1"/1" 1¼"/1" 1¼"/1¼" 1½"/1" 1½"/1¼" 1½"/1½"

Threaded connectionDIN 11851(DIN)

a1  169.0     172.0     175.0     173.0     176.0     179.0     195.0     198.0     201.0     199.0     202.0     205.0    f2  1.0     1.0     4.0     1.0     4.0     7.0     1.0     1.0     4.0     1.0     4.0     7.0    h2  160.0     160.0     160.0     160.0     160.0     160.0     160.0     160.0     160.0     160.0     160.0     160.0    e5 106.0 114.0 114.0 120.0 120.0 120.0 106.0 114.0 114.0 120.0 120.0 120.0 h3 119.0 127.0 127.0 133.0 133.0 133.0 119.0 127.0 127.0 133.0 133.0 133.0

Threaded connectionDIN 11864-1 / DIN 11853-1Pipe range A (DIN)*

a1 166.0 170.0 173.0 171.0 174.0 177.0 192.0 196.0 199.0 197.0 200.0 203.0 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 157.0 157.0 158.0 157.0 158.0 158.0 157.0 157.0 158.0 157.0 158.0 158.0 e5 106.0 113.0 113.0 119.0 119.0 119.0 106.0 113.0 113.0 119.0 119.0 119.0 h3 116.0 125.0 125.0 131.0 131.0 131.0 116.0 125.0 125.0 131.0 131.0 131.0

Threaded connectionDIN 11864-1 / DIN 11853-1Pipe range B (ISO)**

a1 173.0 174.0 177.0 174.0 177.0

(E)

199.0 200.0 203.0 200.0 203.0

(E)f2 4.0 4.0 7.0 4.0 7.0 4.0 4.0 7.0 4.0 7.0 h2 157.0 157.0 159.0 157.0 159.0 157.0 157.0 159.0 157.0 159.0 e5 97.0 106.5 106.5 120.0 120.0 97.0 106.5 106.5 120.0 120.0 h3 108.0 118.5 118.5 128.0 128.0 108.0 118.5 118.5 128.0 128.0

Threaded connection SMS International(OD)

a1 155.0 106.0 109.0 160.0 163.0 166.0 181.0 106.0 109.0 186.0 189.0 192.0f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0h2 150.0 150.0 146.0 150.0 146.0 147.0 150.0 150.0 146.0 150.0 146.0 147.0e5 (A) (A)h3

Threaded connection BS4825-RJT(OD)

a1 161.5 (N/A) (N/A) 161.5 (N/A) 167.5 187.5 (N/A) (N/A) 187.5 (N/A) 193.5f2 1.0 (N/A) (N/A) 1.0 (N/A) 7.0 1.0 (N/A) (N/A) 1.0 (N/A) 7.0h2 152.5 (N/A) (N/A) 152.5 (N/A) 148.5 152.5 (N/A) (N/A) 152.5 (N/A) 148.5e5 (A) (A)h3

Threaded connection ISO2853-IDF(OD)

a1 (A) (N/A) (N/A) (A) (N/A) 164.5 (A) (N/A) (N/A) (A) (N/A) 190.5f2 (A) (N/A) (N/A) (A) (N/A) 7.0 (A) (N/A) (N/A) (A) (N/A) 7.0h2 (A) (N/A) (N/A) (A) (N/A) 145.5 (A) (N/A) (N/A) (A) (N/A) 145.5e5 (A) (A)h3

ClampDIN 32676 Pipe range A (DIN)*

a1 161.5 161.5 164.5 161.5 164.5 167.5 187.5 187.5 190.5 187.5 190.5 193.5 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 152.5 152.5 149.5 152.5 149.5 148.5 152.5 152.5 149.5 152.5 149.5 148.5 e5 113.5 118.5 118.5 123.5 123.5 123.5 113.5 118.5 118.5 123.5 123.5 123.5 h3 111.5 116.5 116.5 121.5 121.5 121.5 111.5 116.5 116.5 121.5 121.5 121.5

ClampDIN 32676 Pipe range B (ISO)**

a1 164.5 164.5 167.5 164.5 167.5

(E)

190.5 190.5 193.5 190.5 193.5

(E)f2 4.0 4.0 7.0 4.0 7.0 4.0 4.0 7.0 4.0 7.0 h2 149.5 149.5 148.5 149.5 148.5 149.5 149.5 148.5 149.5 148.5 e5 101.5 111.0 111.0 120.5 120.5 101.5 111.0 111.0 120.5 120.5 h3 99.5 109.0 109.0 118.5 118.5 99.5 109.0 109.0 118.5 118.5

ClampDIN 32676 Pipe range C (OD)***

a1 161.5 (N/A) (N/A) 161.5 (N/A) 167.5 167.5 (N/A) (N/A) 187.5 (N/A) 193.5 f2 1.0 (N/A) (N/A) 1.0 (N/A) 7.0 7.0 (N/A) (N/A) 1.0 (N/A) 7.0 h2 152.5 (N/A) (N/A) 152.5 (N/A) 163.0 163.0 (N/A) (N/A) 152.5 (N/A) 163.0 e5 99.7 (N/A) (N/A) 118.8 (N/A) 118.8 118.8 (N/A) (N/A) 118.8 (N/A) 118.8 h3 97.7 (N/A) (N/A) 116.8 (N/A) 116.8 116.8 (N/A) (N/A) 116.8 (N/A) 116.8

Grooved flangeDIN 11864-2 / DIN 11853-1 Pipe range A (DIN)*

a1 163.7 163.7 166.7 163.7 166.7 169.7 189.7 189.7 192.7 189.7 192.7 195.7 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 154.7 154.7 151.7 154.7 151.7 150.7 154.7 154.7 151.7 154.7 151.7 150.7 e5 112.5 117.5 117.5 122.5 122.5 122.5 112.5 117.5 117.5 122.5 122.5 122.5 h3 113.7 118.7 118.7 123.7 123.7 123.7 113.7 118.7 118.7 123.7 123.7 123.7

Grooved flangeDIN 11864-2 / DIN 11853-1 Pipe range A (DIN)*

a1 166.7 166.7 169.7 166.7 169.7

(E)

192.7 192.7 195.7 192.7 195.7

(E)f2 4.0 4.0 7.0 4.0 7.0 4.0 4.0 7.0 4.0 7.0 h2 150.7 150.7 150.7 150.7 150.7 150.7 150.7 150.7 150.7 150.7 e5 100.5 110.0 110.0 119.5 119.5 100.5 110.0 110.0 119.5 119.5 h3 101.7 111.2 111.2 120.7 120.7 101.7 111.2 111.2 120.7 120.7

Flange EN1092-1 PN10 Kremo(ISO)

a1 153.0 153.0 156.0 153.0 156.0 159.0 179.0 179.0 182.0 179.0 182.0 185.0 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 144.0 144.0 141.0 144.0 141.0 140.0 144.0 144.0 141.0 144.0 141.0 140.0 e5 (A) (A)h3

Flange connectionAPV-FG / 3.1-PN10(DIN)

a1 164.0 (N/A) (N/A) 164.0 (N/A) 170.0 190.0 (N/A) (N/A) 190.0 (N/A) 196.0f2 1.0 (N/A) (N/A) 1.0 (N/A) 7.0 1.0 (N/A) (N/A) 1.0 (N/A) 7.0h2 155.0 (N/A) (N/A) 155.0 (N/A) 151.0 155.0 (N/A) (N/A) 155.0 (N/A) 151.0e5 (A) (A)h3

Flange connectionAPV-FG / 3.1-PN25(DIN)

a1 (A) (N/A) (N/A) (A) (N/A) 162.0 (A) (N/A) (N/A) (A) (N/A) 188.0f2 (A) (N/A) (N/A) (A) (N/A) 7.0 (A) (N/A) (N/A) (A) (N/A) 7.0h2 (A) (N/A) (N/A) (A) (N/A) 143.0 (A) (N/A) (N/A) (A) (N/A) 143.0e5 (A) (A)h3

Tolerances according to DIN EN 735 Connection dimensions for centrifugal pumps. * For pipes according to DIN 11866 series A** For pipes according to DIN 11866 series B*** For pipes according to DIN 11866 series C (pipe dimensions according to ASME BPE)(A) On request(E) On request. Not fully drainable in vertical position(N/A) Not Available

Page 58: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

58 ·

GEA GEA Hilge CONTRA Pumps

Connection Dimensions GEA Hilge CONTRA I

Nominal width

Connection type

5-stage 6-stage

DIN 25/25 32/25 32/32 40/25 40/32 40/40 25/25 32/25 32/32 40/25 40/32 40/40

ISO 33.7/33.7

42.4/33.7

42.4/42.4

48.3/33.7

48.3/42.4

48.3/48.3

33.7/33.7

42.4/33.7

42.4/42.4

48.3/33.7

48.3/42.4

48.3/48.3

OD 1"/1" 1¼"/1" 1¼"/1¼" 1½"/1" 1½"/1¼" 1½"/1½" 1"/1" 1¼"/1" 1¼"/1¼" 1½"/1" 1½"/1¼" 1½"/1½"

Threaded connectionDIN 11851(DIN)

a1 221.0 224.0 227.0 225.0 228.0 231.0 247.0 250.0 253.0 251.0 254.0 257.0 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 160.0 160.0 160.0 160.0 160.0 160.0 160.0 160.0 160.0 160.0 160.0 160.0 e5 106.0 114.0 114.0 120.0 120.0 120.0 106.0 114.0 114.0 120.0 120.0 120.0 h3 119.0 127.0 127.0 133.0 133.0 133.0 119.0 127.0 127.0 133.0 133.0 133.0

Threaded connectionDIN 11864-1 / DIN 11853-1Pipe range A (DIN)*

a1 218.0 222.0 225.0 223.0 226.0 229.0 244.0 248.0 251.0 249.0 252.0 255.0 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 157.0 157.0 158.0 157.0 158.0 158.0 157.0 157.0 158.0 157.0 158.0 158.0 e5 106.0 113.0 113.0 119.0 119.0 119.0 106.0 113.0 113.0 119.0 119.0 119.0 h3 116.0 125.0 125.0 131.0 131.0 131.0 116.0 125.0 125.0 131.0 131.0 131.0

Threaded connectionDIN 11864-1 / DIN 11853-1Pipe range B (ISO)**

a1 225.0 226.0 229.0 226.0 229.0

(E)

251.0 252.0 255.0 252.0 255.0

(E)f2 4.0 4.0 7.0 4.0 7.0 4.0 4.0 7.0 4.0 7.0h2 157.0 157.0 159.0 157.0 159.0 157.0 157.0 159.0 157.0 159.0e5 97.0 106.5 106.5 120.0 120.0 97.0 106.5 106.5 120.0 120.0h3 108.0 118.5 118.5 128.0 128.0 108.0 118.5 118.5 128.0 128.0

Threaded connection SMS International(OD)

a1 207.0 106.0 109.0 212.0 215.0 218.0 233.0 106.0 109.0 238.0 241.0 244.0f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0h2 150.0 150.0 146.0 150.0 146.0 147.0 150.0 150.0 146.0 150.0 146.0 147.0e5 (A) (A)h3

Threaded connection BS4825-RJT(OD)

a1 213.5 (N/A) (N/A) 213.5 (N/A) 219.5 239.5 (N/A) (N/A) 239.5 (N/A) 245.5f2 1.0 (N/A) (N/A) 1.0 (N/A) 7.0 1.0 (N/A) (N/A) 1.0 (N/A) 7.0h2 152.5 (N/A) (N/A) 152.5 (N/A) 148.5 152.5 (N/A) (N/A) 152.5 (N/A) 148.5e5 (A) (A)h3

Threaded connection ISO2853-IDF(OD)

a1 (A) (N/A) (N/A) (A) (N/A) 216.5 (A) (N/A) (N/A) (A) (N/A) 242.5f2 (A) (N/A) (N/A) (A) (N/A) 7.0 (A) (N/A) (N/A) (A) (N/A) 7.0h2 (A) (N/A) (N/A) (A) (N/A) 145.5 (A) (N/A) (N/A) (A) (N/A) 145.5e5 (A) (A)h3

ClampDIN 32676 Pipe range A (DIN)*

a1 213.5 213.5 216.5 213.5 216.5 219.5 239.5 239.5 242.5 239.5 242.5 245.5 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 152.5 152.5 149.5 152.5 149.5 148.5 152.5 152.5 149.5 152.5 149.5 148.5 e5 113.5 118.5 118.5 123.5 123.5 123.5 113.5 118.5 118.5 123.5 123.5 123.5 h3 111.5 116.5 116.5 121.5 121.5 121.5 111.5 116.5 116.5 121.5 121.5 121.5

ClampDIN 32676 Pipe range B (ISO)**

a1 216.5 216.5 219.5 216.5 219.5

(E)

242.5 242.5 245.5 242.5 245.5

(E)f2 4.0 4.0 7.0 4.0 7.0 4.0 4.0 7.0 4.0 7.0 h2 149.5 149.5 148.5 149.5 148.5 149.5 149.5 148.5 149.5 148.5 e5 101.5 111.0 111.0 120.5 120.5 101.5 111.0 111.0 120.5 120.5 h3 99.5 109.0 109.0 118.5 118.5 99.5 109.0 109.0 118.5 118.5

ClampDIN 32676 Pipe range C (OD)***

a1 213.5 (N/A) (N/A) 213.5 (N/A) 219.5 239.5 (N/A) (N/A) 239.5 (N/A) 245.5 f2 1.0 (N/A) (N/A) 1.0 (N/A) 7.0 1.0 (N/A) (N/A) 1.0 (N/A) 7.0 h2 152.5 (N/A) (N/A) 152.5 (N/A) 163.0 152.5 (N/A) (N/A) 152.5 (N/A) 163.0 e5 99.7 (N/A) (N/A) 118.8 (N/A) 118.8 99.7 (N/A) (N/A) 118.8 (N/A) 118.8 h3 97.7 (N/A) (N/A) 116.8 (N/A) 116.8 97.7 (N/A) (N/A) 116.8 (N/A) 116.8

Grooved flangeDIN 11864-2 / DIN 11853-1 Pipe range A (DIN)*

a1 215.7 215.7 218.7 215.7 218.7 221.7 241.7 241.7 244.7 241.7 244.7 247.7 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 154.7 154.7 151.7 154.7 151.7 150.7 154.7 154.7 151.7 154.7 151.7 150.7 e5 112.5 117.5 117.5 122.5 122.5 122.5 112.5 117.5 117.5 122.5 122.5 122.5 h3 113.7 118.7 118.7 123.7 123.7 123.7 113.7 118.7 118.7 123.7 123.7 123.7

Grooved flangeDIN 11864-2 / DIN 11853-1 Pipe range A (DIN)*

a1 218.7 218.7 221.7 218.7 221.7

(E)

244.7 244.7 247.7 244.7 247.7

(E)f2 4.0 4.0 7.0 4.0 7.0 4.0 4.0 7.0 4.0 7.0h2 150.7 150.7 150.7 150.7 150.7 150.7 150.7 150.7 150.7 150.7e5 100.5 110.0 110.0 119.5 119.5 100.5 110.0 110.0 119.5 119.5h3 101.7 111.2 111.2 120.7 120.7 101.7 111.2 111.2 120.7 120.7

Flange EN1092-1 PN10 Kremo(ISO)

a1 205.0 205.0 208.0 205.0 208.0 211.0 231.0 231.0 234.0 231.0 234.0 237.0 f2 1.0 1.0 4.0 1.0 4.0 7.0 1.0 1.0 4.0 1.0 4.0 7.0 h2 144.0 144.0 141.0 144.0 141.0 140.0 144.0 144.0 141.0 144.0 141.0 140.0 e5 (A) (A)h3

Flange connectionAPV-FG / 3.1-PN10(DIN)

a1 216.0 (N/A) (N/A) 216.0 (N/A) 222.0 242.0 (N/A) (N/A) 242.0 (N/A) 248.0f2 1.0 (N/A) (N/A) 1.0 (N/A) 7.0 1.0 (N/A) (N/A) 1.0 (N/A) 7.0h2 155.0 (N/A) (N/A) 155.0 (N/A) 151.0 155.0 (N/A) (N/A) 155.0 (N/A) 151.0e5 (A) (A)h3

Flange connectionAPV-FG / 3.1-PN25(DIN)

a1 (A) (N/A) (N/A) (A) (N/A) 214.0 (A) (N/A) (N/A) (A) (N/A) 240.0f2 (A) (N/A) (N/A) (A) (N/A) 7.0 (A) (N/A) (N/A) (A) (N/A) 7.0h2 (A) (N/A) (N/A) (A) (N/A) 143.0 (A) (N/A) (N/A) (A) (N/A) 143.0e5 (A) (A)h3

Tolerances according to DIN EN 735 Connection dimensions for centrifugal pumps. * For pipes according to DIN 11866 series A** For pipes according to DIN 11866 series B*** For pipes according to DIN 11866 series C (pipe dimensions according to ASME BPE)(A) On request(E) On request. Not fully drainable in vertical position(N/A) Not Available

Page 59: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis
Page 60: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

60 ·

GEA GEA Hilge CONTRA Pumps

Connection Dimensions GEA Hilge CONTRA II

Nominal width

Connection type

2-stage 3-stage

DIN 50/40 50/50 65/50 65/65 80/65 50/40 50/50 65/50 65/65 65/80

ISO 60.3/48.3

60.3/60.3

76.1/60.3

76.1/76.1

88.9/76.1

60.3/48.3

60.3/60.3

76.1/60.3

76.1/76.1

88.9/76.1

OD 2"/1½" 2"/2" 2½"/2" 2½"/2½" 3"/2½" 2"/1½" 2"/2" 2½"/2" 2½"/2½" 3"/2½"

Threaded connectionDIN 11851(DIN)

a1 156.0 159.0 164.0 172.0 177.0 188.0 191.0 196.0 204.0 209.0f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 205.0 205.0 205.0 205.0 205.0 205.0 205.0 205.0 205.0 205.0e5 132.0 132.0 145.0 145.0 175.0 132.0 132.0 145.0 145.0 175.0h3 142.0 142.0 160.0 160.0 190.0 142.0 142.0 160.0 160.0 190.0

Threaded connectionDIN 11864-1 / DIN 11853-1Pipe range A (DIN)*

a1 152.0 155.0 160.0 168.0 174.0 184.0 187.0 192.0 200.0 206.0f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 203.0 201.0 201.0 201.0 201.0 203.0 201.0 201.0 201.0 201.0e5 133.0 133.0 146.0 146.0 175.0 133.0 133.0 146.0 146.0 175.0h3 141.0 141.0 156.0 156.0 187.0 141.0 141.0 156.0 156.0 187.0

Threaded connectionDIN 11864-1 / DIN 11853-1Pipe range B (ISO)**

a1 157.0 168.0

(A) (E) (E)

189.0 200.0

(A) (E) (E)f2 0.0 11.0 0.0 11.0h2 203.0 201.0 203.0 201.0e5 142.0 142.0 142.0 142.0h3 152.0 152.0 152.0 152.0

Threaded connection SMS International(OD)

a1 (A) 144.0 148.0 156.0 156.0 (A) 176.0 180.0 188.0 188.0f2 (A) 3.0 3.0 11.0 11.0 (A) 3.0 3.0 11.0 11.0h2 (A) 190.0 190.0 189.0 189.0 (A) 190.0 190.0 189.0 189.0e5 (A) (A)h3

Threaded connection BS4825-RJT(OD)

a1 (A) 145.0 145.0 (A) (A) (A) 177.0 177.0 (A) (A)f2 (A) 3.0 3.0 (A) (A) (A) 3.0 3.0 (A) (A)h2 (A) 191.5 191.5 (A) (A) (A) 191.5 191.5 (A) (A)e5 (A) (A)h3

Threaded connection ISO2853-IDF(OD)

a1 (A) 170.5 (A) (A) (A) (A) 202.5 (A) (A) (A)f2 (A) 3.0 (A) (A) (A) (A) 3.0 (A) (A) (A)h2 (A) 191.5 (A) (A) (A) (A) 191.5 (A) (A) (A)e5 (A) (A)h3

ClampDIN 32676 Pipe range A (DIN)*

a1 142.0 145.0 152.0 160.0 160.0 174.0 177.0 184.0 192.0 192.0f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 193.5 191.5 191.5 193.0 193.0 193.5 191.5 191.5 193.0 193.0e5 133.5 133.5 150.0 150.0 175.0 133.5 133.5 150.0 150.0 175.0h3 131.5 131.5 148.0 148.0 173.0 131.5 131.5 148.0 148.0 173.0

ClampDIN 32676 Pipe range B (ISO)**

a1 149.0 160.0 160.0

(E) (E)

181.0 192.0 192.0

(E) (E)f2 0.0 11.0 11.0 0.0 11.0 11.0h2 193.5 201.0 201.0 193.5 201.0 201.0e5 146.0 146.0 180.0 146.0 146.0 180.0h3 144.0 144.0 178.0 144.0 144.0 178.0

ClampDIN 32676 Pipe range C (OD)***

a1 142.0 145.0 152.0 160.0 160.0 174.0 177.0 184.0 192.0 192.0f2 0.0 3.0 8.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 208.0 191.5 191.5 201.0 201.0 208.0 191.5 191.5 201.0 201.0e5 144.2 144.2 169.7 169.7 199.5 144.2 144.2 169.7 169.7 199.5h3 142.2 142.2 167.7 167.7 197.5 142.2 142.2 167.7 167.7 197.5

Grooved flangeDIN 11864-2 / DIN 11853-1 Pipe range A (DIN)*

a1 145.4 148.4 148.4 156.4 158.4 177.4 180.4 180.4 188.4 190.4f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 196.7 194.7 194.7 189.7 189.7 196.7 194.7 194.7 189.7 189.7e5 132.5 132.5 142.5 142.5 169.5 132.5 132.5 142.5 142.5 169.5h3 133.7 133.7 143.7 143.7 170.7 133.7 133.7 143.7 143.7 170.7

Grooved flangeDIN 11864-2 / DIN 11853-1 Pipe range A (DIN)*

a1 173.0 184.0 186.0

(E) (E)

205.0 216.0 218.0

(E) (E)f2 0.0 11.0 11.0 0.0 11.0 11.0h2 195.7 217.0 217.0 195.7 217.0 217.0e5 138.5 138.5 172.5 138.5 138.5 172.5h3 139.7 139.7 173.7 139.7 139.7 173.7

Flange EN1092-1 PN10 Kremo(ISO)

a1 133.5 136.5 146.5 154.5 153.5 165.5 168.5 178.5 186.5 185.5f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 185.0 183.0 183.0 188.0 188.0 185.0 183.0 183.0 188.0 188.0e5 (A) (A)h3

Flange connectionAPV-FG / 3.1-PN10(DIN)

a1 144.5 147.5 147.5 155.5 155.5 176.5 179.5 179.5 187.5 187.5f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 196.0 194.0 194.0 189.0 189.0 196.0 194.0 194.0 189.0 189.0e5 (A) (A)h3

Flange connectionAPV-FG / 3.1-PN25(DIN)

a1 140.5 143.5 143.5 151.5 155.5 172.5 175.5 175.5 183.5 187.5f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 0.0h2 192.0 190.0 190.0 185.0 185.0 192.0 190.0 190.0 185.0 185.0e5 (A) (A)h3

Tolerances according to DIN EN 735 Connection dimensions for centrifugal pumps.* For pipes according to DIN 11866 series A** For pipes according to DIN 11866 series B*** For pipes according to DIN 11866 series C (pipe dimensions according to ASME BPE)(A) On request(E) On request. Not fully drainable in vertical position(N/A) Not Available

Page 61: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 61

GEA GEA Hilge CONTRA Pumps

Connection Dimensions GEA Hilge CONTRA II

Nominal width

Connection type

4-stage 5-stage

DIN 50/40 50/50 65/50 65/65 80/65 50/40 50/50 65/50 65/65 65/80

ISO 60.3/48.3

60.3/60.3

76.1/60.3

76.1/76.1

88.9/76.1

60.3/48.3

60.3/60.3

76.1/60.3

76.1/76.1

88.9/76.1

OD 2"/1½" 2"/2" 2½"/2" 2½"/2½" 3"/2½" 2"/1½" 2"/2" 2½"/2" 2½"/2½" 3"/2½"

Threaded connectionDIN 11851(DIN)

a1 220.0 223.0 228.0 236.0 241.0 252.0 255.0 260.0 268.0 273.0f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 205.0 205.0 205.0 205.0 205.0 205.0 205.0 205.0 205.0 205.0e5 132.0 132.0 145.0 145.0 175.0 132.0 132.0 145.0 145.0 175.0h3 142.0 142.0 160.0 160.0 190.0 142.0 142.0 160.0 160.0 190.0

Threaded connectionDIN 11864-1 / DIN 11853-1Pipe range A (DIN)*

a1 216.0 219.0 224.0 232.0 238.0 248.0 251.0 256.0 264.0 270.0f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 203.0 201.0 201.0 201.0 201.0 203.0 201.0 201.0 201.0 201.0e5 133.0 133.0 146.0 146.0 175.0 133.0 133.0 146.0 146.0 175.0h3 141.0 141.0 156.0 156.0 187.0 141.0 141.0 156.0 156.0 187.0

Threaded connectionDIN 11864-1 / DIN 11853-1Pipe range B (ISO)**

a1 221.0 232.0

(A) (E) (E)

253.0 264.0

(A) (E) (E)f2 0.0 11.0 0.0 11.0h2 203.0 201.0 203.0 201.0e5 142.0 142.0 142.0 142.0h3 152.0 152.0 152.0 152.0

Threaded connection SMS International(OD)

a1 (A) 208.0 212.0 220.0 220.0 (A) 240.0 244.0 252.0 252.0f2 (A) 3.0 3.0 11.0 11.0 (A) 3.0 3.0 11.0 11.0h2 (A) 190.0 190.0 189.0 189.0 (A) 190.0 190.0 189.0 189.0e5 (A) (A)h3

Threaded connection BS4825-RJT(OD)

a1 (A) 209.0 209.0 (A) (A) (A) 241.0 241.0 (A) (A)f2 (A) 3.0 3.0 (A) (A) (A) 3.0 3.0 (A) (A)h2 (A) 191.5 191.5 (A) (A) (A) 191.5 191.5 (A) (A)e5 (A) (A)h3

Threaded connection ISO2853-IDF(OD)

a1 (A) 234.5 (A) (A) (A) (A) 266.5 (A) (A) (A)f2 (A) 3.0 (A) (A) (A) (A) 3.0 (A) (A) (A)h2 (A) 191.5 (A) (A) (A) (A) 191.5 (A) (A) (A)e5 (A) (A)h3

ClampDIN 32676 Pipe range A (DIN)*

a1 206.0 209.0 216.0 224.0 224.0 238.0 241.0 248.0 256.0 256.0f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 193.5 191.5 191.5 193.0 193.0 193.5 191.5 191.5 193.0 193.0e5 133.5 133.5 150.0 150.0 175.0 133.5 133.5 150.0 150.0 175.0h3 131.5 131.5 148.0 148.0 173.0 131.5 131.5 148.0 148.0 173.0

ClampDIN 32676 Pipe range B (ISO)**

a1 213.0 224.0 224.0

(E) (E)

245.0 256.0 256.0

(E) (E)f2 0.0 11.0 11.0 0.0 11.0 11.0h2 193.5 201.0 201.0 193.5 201.0 201.0e5 146.0 146.0 180.0 146.0 146.0 180.0h3 144.0 144.0 178.0 144.0 144.0 178.0

ClampDIN 32676 Pipe range C (OD)***

a1 206.0 209.0 216.0 224.0 224.0 238.0 241.0 248.0 256.0 256.0f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 208.0 191.5 191.5 201.0 201.0 208.0 191.5 191.5 201.0 201.0e5 144.2 144.2 169.7 169.7 199.5 144.2 144.2 169.7 169.7 199.5h3 142.2 142.2 167.7 167.7 197.5 142.2 142.2 167.7 167.7 197.5

Grooved flangeDIN 11864-2 / DIN 11853-1 Pipe range A (DIN)*

a1 209.4 212.4 212.4 220.4 222.4 241.4 244.4 244.4 252.4 254.4f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 196.7 194.7 194.7 189.7 189.7 196.7 194.7 194.7 189.7 189.7e5 132.5 132.5 142.5 142.5 169.5 132.5 132.5 142.5 142.5 169.5h3 133.7 133.7 143.7 143.7 170.7 133.7 133.7 143.7 143.7 170.7

Grooved flangeDIN 11864-2 / DIN 11853-1 Pipe range A (DIN)*

a1 237.0 248.0 250.0

(E) (E)

269.0 280.0 282.0

(E) (E)f2 0.0 11.0 11.0 0.0 11.0 11.0h2 195.7 217.0 217.0 195.7 217.0 217.0e5 138.5 138.5 172.5 138.5 138.5 172.5h3 139.7 139.7 173.7 139.7 139.7 173.7

Flange EN1092-1 PN10 Kremo(ISO)

a1 197.5 200.5 210.5 218.5 217.5 229.5 232.5 242.5 250.5 249.5f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 185.0 183.0 183.0 188.0 188.0 185.0 183.0 183.0 188.0 188.0e5 (A) (A)h3

Flange connectionAPV-FG / 3.1-PN10(DIN)

a1 208.5 211.5 211.5 219.5 219.5 240.5 243.5 243.5 251.5 251.5f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 196.0 194.0 194.0 189.0 189.0 196.0 194.0 194.0 189.0 189.0e5 (A) (A)h3

Flange connectionAPV-FG / 3.1-PN25(DIN)

a1 204.5 207.5 207.5 215.5 219.5 236.5 239.5 239.5 247.5 252.5f2 0.0 3.0 3.0 11.0 11.0 0.0 3.0 3.0 11.0 11.0h2 192.0 190.0 190.0 185.0 185.0 192.0 190.0 190.0 185.0 185.0e5 (A) (A)h3

Tolerances according to DIN EN 735 Connection dimensions for centrifugal pumps. * For pipes according to DIN 11866 series A** For pipes according to DIN 11866 series B*** For pipes according to DIN 11866 series C (pipe dimensions according to ASME BPE)(A) On request(E) On request. Not fully drainable in vertical position(N/A) Not Available

Page 62: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA

62 · Pump Selection Matrix

GEA Hilge CONTRA I

Page 63: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 63

1

GEA Hilge CONTRA I

GEA Hilge CONTRA I Bloc

GEA Hilge CONTRA I Bloc-SUPER

GEA Hilge CONTRA I Bloc-V

GEA Hilge CONTRA I Adapta

GEA Hilge CONTRA I Adapta-SUPER

GEA Hilge CONTRA I Adapta-V

Page 64: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

64 ·

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA I Bloc on Motor Foot

P2[kW]

IEC- size

h1 [mm]

k3(1)

[mm]u(1)

[mm]w1

[mm]m1

[mm]m2

[mm]n1

[mm]n2

[mm]s1

[mm]Weight

[kg]

0.75 80 80 240 140 50 125 100 160 125 9×13 21

1.1 80 80 240 140 50 125 100 160 125 9×13 24

1.5 90S 90 275 150 56 150 100 170 140 10×14 27

2.2 90L 90 275 150 56 150 125 170 140 10×14 33

3.0 100L 100 330 160 78 170 140 200 160 12×16 37

4.0 112M 112 360 175 90 175 140 220 190 12×16 42

5.5 112M 112 360 175 90 175 140 220 190 12×16 47

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

a1

u

f2

w1 m2

DN

k3 113 - f2

m1

P.10

1.00

00.0

037R

1

S

(1)

(1)

s1

DN

n2 n1

h1

h2

55

200

D

(4)

* registered for recertification

Page 65: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 65

1

GEA Hilge CONTRA I Bloc on Combi Foot

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

P2[kW]

IEC- size

k3(1)

[mm]u(1)

[mm]Weight

[kg]

0.75 80 240 140 25

1.1 80 240 140 28

1.5 90S 275 150 31

2.2 90L 275 150 36

3.0 100L 330 160 43

4.0 112M 360 175 48

5.5 112M 360 175 53

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

a1

f2

DN

k3 113 - f2

80 300

50

u

P.10

1.00

00.0

038R

1

S

(1)

(1)

DN

260

200

±5

h2

55

200

310

D

(4)

* registered for recertification

Page 66: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

66 · GEA Hilge CONTRA I Bloc on Cast Iron Foot

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

P2[kW]

IEC- size

k3(1)

[mm]u(1)

[mm]Weight

[kg]

0.75 80 240 140 26

1.1 80 240 140 29

1.5 90S 275 150 33

2.2 90L 275 150 38

3.0 100L 330 160 42

4.0 112M 360 175 47

5.5 112M 360 175 52

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

a1

f2

DN

k3 113 - f2

58

u

200

35

270

16

P.10

1.00

00.0

039R

1

S

(1)

(1)

Ø14

DN

200

h

2

55

200

200

230

D

(4)

* registered for recertification

Page 67: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 67

1

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA I Bloc on Stainless Steel Foot

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

P2[kW]

IEC- size

k3(1)

[mm]u(1)

[mm]Weight

[kg]

0.75 80 240 140 24

1.1 80 240 140 27

1.5 90S 275 150 31

2.2 90L 275 150 36

3.0 100L 330 160 41

4.0 112M 360 175 46

5.5 112M 360 175 51

2-pole

a1

f2

DN

k3 113 - f2

75

u

25

6

150

200

P.10

1.00

00.0

040R

1

S

(1)

(1)

Ø14

DN

206

h

2

55

200

160

200

D

(4)

* registered for recertification

Page 68: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

68 ·

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA I Bloc-SUPER on Combi Foot

a1

f2

DN

L

L - f2

d

80 300

50

P.101.0000.0041R1

S

H

H

DN

200

±5

h2

55

200

260

310

D

(4)

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

P2[kW]

IEC- size

I [mm]

lH [mm]

ødH

[mm]Weight

[kg]

0.75 80 496 450 220 27

1.1 80 496 450 220 30

1.5 90S 496 450 220 33

2.2 90L 496 450 220 39

3.0 100L 566 520 270 46

4.0 112M 566 520 270 52

5.5 112M 566 520 270 57

2-pole

* registered for recertification

Page 69: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 69

1

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA I Bloc-SUPER on Cast Iron Foot

a1

f2

DN

L

L - f2

16

d

35

58

270

200

P.101.0000.0042R1

S

Ø14

H

H

DN

200

h

2

55

200

200

230

D

(4)

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

P2[kW]

IEC- size

I [mm]

lH [mm]

ødH

[mm]Weight

[kg]

0.75 80 496 450 220 28

1.1 80 496 450 220 31

1.5 90S 496 450 220 35

2.2 90L 496 450 220 40

3.0 100L 566 520 270 46

4.0 112M 566 520 270 51

5.5 112M 566 520 270 56

2-pole

* registered for recertification

Page 70: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

70 · GEA Hilge CONTRA I Bloc-SUPER on Stainless Steel Foot

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

a1

f2

DN

L

L - f2

75

25

6

150

200

d

P.101.0000.0043R1

S

Ø14

HH

DN

206

h

2

55

200

160

200

D

(4)

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

P2[kW]

IEC- size

I [mm]

lH [mm]

ødH

[mm]Weight

[kg]

0.75 80 496 450 220 27

1.1 80 496 450 220 30

1.5 90S 496 450 220 33

2.2 90L 496 450 220 39

3.0 100L 566 520 270 44

4.0 112M 566 520 270 50

5.5 112M 566 520 270 55

* registered for recertification

Page 71: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 71

1

GEA Hilge CONTRA I Bloc-V on Vertical Stand

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, h3, e1, e5). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.Weight: net-weight without packaging

P2[kW]

IEC- size

k3(1)

[mm]u(1)

[mm]Weight

[kg]

0.75 80 240 140 36

1.1 80 240 140 37

1.5 90S 275 150 46

2.2 90L 275 150 48

3.0 100L 330 160 59

4.0 112M 360 175 70

5.5 112M 360 175 94

a1

k3

f2

DN

113

- f

2 e

5

DN

78

1–3

stag

es:

533

4–6

stag

es:

663

10

157 h3 h2

u

P.101.0000.0052R2

S

(1)

D

(1)

260

300

210

250

13

55

Top view(w/o terminal box)

* registered for recertification

Page 72: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

72 ·

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA I Adapta / Adapta-tronic on Combi Foot (80–90)

Standard tronic

P2[kW]

IEC- size

b [mm]

p6 [mm]

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

0.75 80 0 200 320 130 – – 40

1.1 80 0 200 320 130 – – 41

1.5 90S 10 200 340 150 274 158 51

2.2 90L 10 200 340 150 274 158 52

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

a1

f2

DN

131 50

254 - f2

b

k3 u

300

P.10

1.00

00.0

044R

1

S

(1)(1

)

Ø200 Ø p6

DN

260

200

±5

h2

55

310

200

D

(4)

* registered for recertification

Page 73: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 73

1

GEA Hilge CONTRA I Adapta / Adapta-tronic on Combi Foot (100–132)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

Standard tronic

P2[kW]

IEC- size

b [mm]

p6 [mm]

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

3.0 100L 20 250 370 175 334 201 65

4.0 112M 20 250 380 185 334 201 75

5.5 132S 40 300 450 205 365 201 99

a1

f2

DN

131 50

254 - f2 b k3 u

404

P.10

1.00

00.0

045R

1

S

(1)(1

)

Ø200 Ø p6

DN

300 2

00 ±

5 h

2

55

350

200

D

(4)

* registered for recertification

Page 74: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

74 ·

a1

f2

DN

254 - f2 b k3

u

27.5

139 220

275

22

P.10

1.00

00.0

046R

1

S

(1)

(1)

Ø14

Ø200 Ø p6

DN

200

h

2

55

200

215

250

D

(4)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA I Adapta / Adapta-tronic on Cast Iron Foot

Standard tronic

P2[kW]

IEC- size

b [mm]

p6 [mm]

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

0.75 80 0 200 320 130 – – 45

1.1 80 0 200 320 130 – – 46

1.5 90S 10 200 340 150 274 158 55

2.2 90L 10 200 340 150 274 158 56

3.0 100L 20 250 370 175 334 201 68

4.0 112M 20 250 380 185 334 201 78

5.5 132S 40 300 450 205 365 201 102

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging for standard motor

* registered for recertification

Page 75: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 75

1

a1

f2

DN

254 - f2 b k3 u

27.5

139 220

275

6

P.10

1.00

00.0

047R

1

S

(1)(1

)

Ø14

Ø200 Ø p6 DN

200

h

2

55

200

215

250

D

(4)

GEA Hilge CONTRA I Adapta / Adapta-tronic on Stainless Steel Foot

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

Standard tronic

P2[kW]

IEC- size

b [mm]

p6 [mm]

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

0.75 80 0 200 320 130 – – 41

1.1 80 0 200 320 130 – – 42

1.5 90S 10 200 340 150 274 158 51

2.2 90L 10 200 340 150 274 158 53

3.0 100L 20 250 370 175 334 201 64

4.0 112M 20 250 380 185 334 201 74

5.5 132S 40 300 450 205 365 201 98

* registered for recertification

Page 76: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

76 ·

a1

f2

DN

h

d

L

L - f2

50 300 131

P.101.0000.0048R1

S

H

H

HØ200

DN

200

±5

h2

55

260

310

D

GEA Hilge CONTRA I Adapta-SUPER on Combi Foot (80–90)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.Weight: net-weight without packaging

P2[kW]

IEC- size

IH [mm]

hH [mm]

ødH

[mm]Weight

[kg]

0.75 80 410 180 320 45

1.1 80 410 180 320 46

1.5 90S 410 180 320 56

2.2 90L 410 180 320 57

* registered for recertification

Page 77: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 77

1 a1

f2

DN

h

d

L

L - f2

50 404 131

P.101.0000.0049R1

S

HH

H

Ø200

DN

200

±5

h2

55

300

350

D

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA I Adapta-SUPER on Combi Foot (100–132)

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.Weight: net-weight without packaging

P2[kW]

IEC- size

IH [mm]

hH [mm]

ødH

[mm]Weight

[kg]

3.0 100L 460 210 370 71

4.0 112M 460 210 370 82

5.5 132S 570 240 420 107

* registered for recertification

Page 78: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

78 ·

a1

f2

DN

27.5

139 220

275

22

h

d

L

L - f2

P.101.0000.0050R1

S

Ø14

H

H

HØ200

DN

200

h

2

55

215

250

D

GEA Hilge CONTRA I Adapta-SUPER on Cast Iron Foot

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.Weight: net-weight without packaging

P2[kW]

IEC- size

IH [mm]

hH [mm]

ødH

[mm]Weight

[kg]

0.75 80 410 180 320 49

1.1 80 410 180 320 50

1.5 90S 410 180 320 60

2.2 90L 410 180 320 61

3.0 100L 460 210 370 74

4.0 112M 460 210 370 84

5.5 132S 570 240 420 110

* registered for recertification

Page 79: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 79

1

a1

f2

DN

L

L - f2

75

25

6

150

200

d

P.101.0000.0043R1

S

Ø14

H

H

DN

206

h

2

55

200

160

200

D

(4)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA I Adapta-SUPER on Stainless Steel Foot

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

P2[kW]

IEC- size

IH [mm]

hH [mm]

ødH

[mm]Weight

[kg]

0.75 80 410 180 320 46

1.1 80 410 180 320 47

1.5 90S 410 180 320 56

2.2 90L 410 180 320 58

3.0 100L 460 210 370 70

4.0 112M 460 210 370 81

5.5 132S 570 240 420 106

* registered for recertification

Page 80: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

80 ·

a1

k3

u

f2

DN

254

- f

2 b

e

5

DN

132

1–

3 st

ages

: 53

04–

6 st

ages

: 66

0

10

150 h3

h2

P.10

1.00

00.0

053R

1

S

(1)

(1)

D

Ø200

Ø p6

260

300

210

250

13

55

Top view(w/o terminal box)

GEA Hilge CONTRA I Adapta / Adapta-tronic on Vertical Stand

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 25–40, pressure side DN 25–40

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 15 m³/h

Flow rate 60 Hz Max. 15 m³/h

Pump head 50 Hz Max. 98 m

Pump head 60 Hz Max. 98 m

Housing pressure 25 bar

Certificates *

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.Weight: net-weight without packaging

Standard tronic

P2[kW]

IEC- size

b [mm]

p6 [mm]

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

0.75 80 0 200 280 145 – – 47

1.1 80 0 200 280 145 – – 48

1.5 90S 10 200 320 150 274 158 58

2.2 90L 10 200 320 150 274 158 60

3.0 100L 20 250 340 175 334 201 71

4.0 112M 20 250 370 185 334 201 70

5.5 132S 40 300 450 205 365 201 105

* registered for recertification

Page 81: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

1

Page 82: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

82 · GEA Hilge CONTRA I, 32 / 32 (130 × 6) 1-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 83: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 83

1

GEA Hilge CONTRA I, 32 / 32 (130 × 6) 2-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 84: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

84 · GEA Hilge CONTRA I, 32 / 32 (130 × 6) 3-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 85: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 85

1

GEA Hilge CONTRA I, 32 / 32 (130 × 6) 4-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 86: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

86 · GEA Hilge CONTRA I, 32 / 32 (130 × 6) 5-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 87: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 87

1

GEA Hilge CONTRA I, 32 / 32 (130 × 6) 6-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 88: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

88 · GEA Hilge CONTRA I, 40 / 40 (130 × 6) 1-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 89: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 89

1

GEA Hilge CONTRA I, 40 / 40 (130 × 6) 2-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 90: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

90 · GEA Hilge CONTRA I, 40 / 40 (130 × 6) 3-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 91: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 91

1

GEA Hilge CONTRA I, 40 / 40 (130 × 6) 4-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 92: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

92 · GEA Hilge CONTRA I, 40 / 40 (130 × 6) 5-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 93: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 93

1

GEA Hilge CONTRA I, 40 / 40 (130 × 6) 6-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 94: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

94 · GEA Hilge CONTRA I, 32 / 32 (130 × 6) 1-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 95: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 95

1

GEA Hilge CONTRA I, 32 / 32 (130 × 6) 2-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 96: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

96 · GEA Hilge CONTRA I, 32 / 32 (130 × 6) 3-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 97: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 97

1

GEA Hilge CONTRA I, 32 / 32 (130 × 6) 4-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 98: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

98 · GEA Hilge CONTRA I, 40 / 40 (130 × 6) 1-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 99: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 99

1

GEA Hilge CONTRA I, 40 / 40 (130 × 6) 2-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 100: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

100 · GEA Hilge CONTRA I, 40 / 40 (130 × 6) 3-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 101: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA I

· 101

1

GEA Hilge CONTRA I, 40 / 40 (130 × 6) 4-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 102: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA

102 · Pump Selection Matrix

GEA Hilge CONTRA II

Page 103: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 103

2

GEA Hilge CONTRA II

GEA Hilge CONTRA II Bloc

GEA Hilge CONTRA II Bloc-SUPER

GEA Hilge CONTRA II Bloc-V

GEA Hilge CONTRA II Adapta

GEA Hilge CONTRA II Adapta-SUPER

GEA Hilge CONTRA II Adapta-V

Page 104: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

104 ·

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA II Bloc on Motor Foot

a1

u

f2

w1 m2

DN

k3

m1

107 - f2

P.10

2.00

00.0

022R

1

S

(1)

(1)

s1

DN

n1

h1

h2

75

n2

270

D

(4)

P2[kW]

IEC- size

h1 [mm]

k3(1)

[mm]u(1)

[mm]w1

[mm]m1

[mm]m2

[mm]n1

[mm]n2

[mm]s1

[mm]Weight

[kg]

4.0 112M 112 340 175 70 175 140 220 190 12×16 64

5.5 112M 132 430 200 109 180 140 256 216 12×16 70

7.5 132S 132 430 200 109 180 140 256 216 12×16 78

11.0 132M 132 450 200 109 210 178 260 216 12×16 116

15.0 160M 160 530 225 120 260 210 320 254 15×19 125

18.5 160L 160 565 225 120 305 254 320 254 15×19 140

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

* registered for recertification

Page 105: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 105

2

GEA Hilge CONTRA II Bloc on Combi Foot (90–132)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

P2[kW]

IEC- size

k3(1)

[mm]u(1)

[mm]Weight

[kg]

4.0 112M 340 175 67

5.5 112M 430 200 74

7.5 132S 430 200 81

11.0 132M 450 200 120

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

a1

u

f2

DN

k3 107 - f2

75 300

50

P.10

2.00

00.0

023R

1

S

(1)

(1)

DN

225

±5

h2

75

270

260 310

D

(4)

* registered for recertification

Page 106: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

106 ·

a1 u

f2

DN

k3 107 - f2

75 404

50

P.102.0000.0024R1

S

(1)(1

)

DN

225

±5

h2

75

270

300 350

D

(4)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA II Bloc on Combi Foot (160)

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

2-pole

P2[kW]

IEC- size

k3(1)

[mm]u(1)

[mm]Weight

[kg]

15.0 160M 530 225 131

18.5 160L 565 255 146

* registered for recertification

Page 107: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 107

2

GEA Hilge CONTRA II Bloc on Cast Iron Foot

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

P2[kW]

IEC- size

k3(1)

[mm]u(1)

[mm]Weight

[kg]

4.0 112M 340 175 72

5.5 112M 430 200 78

7.5 132S 430 200 86

11.0 132M 450 200 124

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

a1 u

f2

DN

k3 107 - f2

27.5

82.5 220

275

22

P.10

2.00

00.0

025R

1

S

(1)(1

)

Ø14

DN

225

h

2

75

270

215

250

D

(4)

* registered for recertification

Page 108: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

108 ·

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA II Bloc on Stainless Steel Foot

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

P2[kW]

IEC- size

k3(1)

[mm]u(1)

[mm]Weight

[kg]

4.0 112M 340 175 68

5.5 112M 430 200 75

7.5 132S 430 200 82

11.0 132M 430 200 121

2-pole

a1 u

f2

DN

k3 107 - f2

82.5 27.5

220

275

6

P.10

2.00

00.0

026R

1

S

(1)(1

)

Ø14

DN

225

h

2

75

270

216 250

D

(4)

* registered for recertification

Page 109: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 109

2

a1

f2

DN

75 300

50

L

d

L - f2

P.102.0000.0027R1

S

HH

DN

225

±5

h2

75

270

260 310

D

(4)

GEA Hilge CONTRA II Bloc-SUPER on Combi Foot (90–132)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

P2[kW]

IEC- size

I [mm]

lH [mm]

ødH

[mm]Weight

[kg]

4.0 112M 573 520 270 70

5.5 112M 573 520 270 77

7.5 132S 653 600 320 86

11.0 132M 653 600 320 124

* registered for recertification

Page 110: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

110 ·

a1

f2

DN

75 404

50

L

L - f2

d

P.102.0000.0028R1

S

H

H

DN

225

±5

h2

75

270

300 350

D

(4)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA II Bloc-SUPER on Combi Foot (160)

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

P2[kW]

IEC- size

I [mm]

lH [mm]

ødH

[mm]Weight

[kg]

15.0 160M 803 750 350 136

18.5 160L 803 750 350 151

* registered for recertification

Page 111: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 111

2

a1

f2

DN

27.5

82.5 220

275

22

d

L

L - f2

P.102.0000.0029R1

S

HH

Ø14

DN

225

h

2

75

270

215

250

D

(4)

GEA Hilge CONTRA II Bloc-SUPER on Cast Iron Foot

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

P2[kW]

IEC- size

I [mm]

lH [mm]

ødH

[mm]Weight

[kg]

4.0 112M 573 520 270 75

5.5 112M 573 520 270 81

7.5 132S 653 600 320 90

11.0 132M 653 600 320 128

* registered for recertification

Page 112: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

112 ·

a1

f2

DN

82.5 27.5

220

275

6

d

L

L - f2

P.102.0000.0030R1

S

HH

Ø14

DN

225

h

2

75

270

216 250

D

(4)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA II Bloc-SUPER on Stainless Steel Foot

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(4) Largest diameter for pump without motor.Weight: net-weight without packaging

P2[kW]

IEC- size

I [mm]

lH [mm]

ødH

[mm]Weight

[kg]

4.0 112M 573 520 270 71

5.5 112M 573 520 270 78

7.5 132S 653 600 320 86

11.0 132M 653 600 320 125

2-pole

* registered for recertification

Page 113: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 113

2

12

103

4

225

.5

e5

a1

107

-f2

k3

u

f2

DN

375 h3

h2

DN

DN S

SD

(1)

(1)

P.102.0000.0042R1

490

490

14

400

400

14

75

Top view(w/o terminal box)

GEA Hilge CONTRA II Bloc-V on Vertical Stand

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.Weight: net-weight without packaging

P2[kW]

IEC- size

k3(1)

[mm]u(1)

[mm]Weight

[kg]

4.0 112M 340 175 110

5.5 112M 430 200 117

7.5 132S 430 200 124

11.0 132M 450 200 163

15.0 160M 530 225 172

18.5 160L 565 225 187

* registered for recertification

Page 114: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

114 ·

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA II Adapta / Adapta-tronic on Combi Foot

Standard tronic

P2[kW]

IEC- size

b [mm]

p6 [mm]

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

4.0 112M 0 250 380 185 334 201 95

5.5 132S 20 300 450 205 365 201 121

7.5 132S 20 300 450 205 389 237 130

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.Weight: net-weight without packaging for standard motor

a1 (304-f2) b k3

u

f2

DN

50 404 156

P.10

2.00

00.0

031R

1

S

(1)

(1)

Ø250 Ø p6 DN

h2

225

±5

75

300 350

D

* registered for recertification

Page 115: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 115

2

GEA Hilge CONTRA II Adapta / Adapta-tronic on Adjustable Feet (160)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

Standard tronic

P2[kW]

IEC- size

b [mm]

p6 [mm]

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

11.0 160M 51 350 570 260 406 237 163

15.0 160M 51 350 570 260 471 308 170

18.5 160L 51 350 580 260 515 308 192

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.Weight: net-weight without packaging

a1 304-f2 51 k3

u

f2

232 570

50

DN

P.102.0000.0032R1

S

(1)

(1)

Ø250

Ø350

DN 75

h2

225

±5

275

D

* registered for recertification

Page 116: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

116 · GEA Hilge CONTRA II Adapta / Adapta-tronic on Adjustable Feet (180)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

Standard tronic

P2[kW]

IEC- size

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

22.0 180L 620 290 541 308 283

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.Weight: net-weight without packaging

a1 (503-f2) k3

u

f2

490

DN

50

168 806

50

220

P.102.0000.0036R2

S

(1)

(1)

Ø250Ø350

DN

75

h2

270

±5

220

298

D

* registered for recertification

Page 117: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 117

2

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA II Adapta / Adapta-tronic on Cast Iron Foot

Standard tronic

P2[kW]

IEC- size

b [mm]

p6 [mm]

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

4.0 112M 0 250 380 185 334 201 97

5.5 132S 20 300 450 205 365 201 123

7.5 132S 20 300 450 205 389 237 132

11.0 160M 51 350 570 260 406 237 160

15.0 160M 51 350 570 260 471 308 167

18.5 160L 51 350 580 260 515 308 189

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.Weight: net-weight without packaging

a1 b k3

u

f2

DN

27.5 220

275

22

163.5

304-f2 P.

102.

0000

.003

3R1

S

(1)

(1)

Ø250 Ø p6

Ø14

DN

h2

225

75

215

250

D

* registered for recertification

Page 118: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

118 · GEA Hilge CONTRA II Adapta / Adapta-tronic on Stainless Steel Foot

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.Weight: net-weight without packaging

Standard tronic

P2[kW]

IEC- size

b [mm]

p6 [mm]

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

4.0 112M 0 250 380 185 334 201 93

5.5 132S 20 300 450 205 365 201 120

7.5 132S 20 300 450 205 389 237 129

11.0 160M 51 350 570 260 406 237 156

15.0 160M 51 350 570 260 471 308 164

18.5 160L 51 350 580 260 515 308 185

a1 b k3

u

f2

DN

6

304-f2

27.5

163.5 220

275

P.10

2.00

00.0

034R

1

S

(1)

(1)

Ø250 Ø p6

Ø14

DN

h2

225

75

216

250

D

* registered for recertification

Page 119: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 119

2

a1 503-f2 k3

u

f2

DN

25

168 220

270

P.102.0000.0035R1

S

(1)

(1)

Ø250Ø350

DN

75

h2

225

220

270 1

4

D

Ø17.5

GEA Hilge CONTRA II Adapta / Adapta-tronic on Adapta Foot

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.Weight: net-weight without packaging

Standard tronic

P2[kW]

IEC- size

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

22.0 180M 620 290 541 308 273

2-pole

* registered for recertification

Page 120: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

120 · GEA Hilge CONTRA II Adapta-SUPER on Combi Foot

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

P2[kW]

IEC- size

IH [mm]

hH [mm]

ødH

[mm]Weight

[kg]

4.0 112M 510 240 420 102

5.5 132S 510 240 420 129

7.5 132S 510 240 420 138

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.Weight: net-weight without packaging

2-pole

a1 287-f2

f2

DN

L

h

d

50

404 156

P.102.0000.0037R1

S

Ø250

H

H

H

DN 75

h2

225

±5

300 350

D

* registered for recertification

Page 121: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 121

2

GEA Hilge CONTRA II Adapta-SUPER on Adjustable Feet (160)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

P2[kW]

IEC- size

Weight [kg]

11.0 160M 175

15.0 160M 182

18.5 160L 204

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.Weight: net-weight without packaging

a1 287-f2

f2

DN

L h

d

50

404 156

P.102.0000.0037R1

S

Ø250

HH

H

DN 75

h2

225

±5

300 350

D

* registered for recertification

Page 122: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

122 · GEA Hilge CONTRA II Adapta-SUPER on Adjustable Feet (180)

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

P2[kW]

IEC- size

LH [mm]

HH [mm]

hH [mm]

dH [mm]

Weight [kg]

22.0 180M 736 512 307 413 303

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.Weight: net-weight without packaging

a1

f2

DN

490

50 50

1176 - f2

h

H

L

168

220

806

P.102.0000.0041R1

S

Ø350

H

H

H

DN

75

h2

220

298

348 2

70 ±

5

d

D

H

* registered for recertification

Page 123: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 123

2

GEA Hilge CONTRA II Adapta-SUPER on Cast Iron Foot

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

P2[kW]

IEC- size

IH [mm]

hH [mm]

ødH [mm]

Weight [kg]

4.0 112M 510 240 420 104

5.5 132S 510 240 420 131

7.5 132S 510 240 420 140

11.0 160M 650 285 485 172

15.0 160M 650 285 485 179

18.5 160L 650 285 485 201

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.Weight: net-weight without packaging

a1 287-f2

f2

163.5

DN

L h

d

27.5

220

275

22

P.102.0000.0039R1

S

Ø250

Ø14

HH

H

DN 75

h2

225

215

250

D

* registered for recertification

Page 124: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

124 ·

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA II Adapta-SUPER on Stainless Steel Foot

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, e1). See table of connections.Weight: net-weight without packaging

P2[kW]

IEC- size

IH [mm]

hH [mm]

ødH

[mm]Weight

[kg]

4.0 112M 510 240 420 101

5.5 132S 510 240 420 127

7.5 132S 510 240 420 136

11.0 160M 650 285 485 168

15.0 160M 650 285 485 176

18.5 160L 650 285 485 197

a1 287-f2

f2

DN

L

h

d

27.5

163.5 220

275

6

P.102.0000.0040R1

S

Ø250

H

H

H

Ø14

DN 75

h2

225

216

250

D

* registered for recertification

Page 125: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 125

2

Technical data of the standard version

Materials Pump housing: stainless steel 316L (1.4404/1.4435) Impeller: precision casting 316L (1.4404)

Connections Thread DIN 11851

Nominal width of connections Suction side DN 50–80, pressure side DN 40–65

Mechanical seal Single mechanical seal, material carbon/stainless steel/EPDM (FDA, USP Class VI)

Static seals EPDM (FDA, USP Class VI)

Motor Standard motor: IEC-Motor, 3 × 380 / 400 / 415 V / 50 Hz, IP 55,ISO-Class F, incl. PTC thermistor, IE3

Documentation Operating instructions, declaration of conformity, pump test report

Flow rate 50 Hz Max. 40 m³/h

Flow rate 60 Hz Max. 35 m³/h

Pump head 50 Hz Max. 160 m

Pump head 60 Hz Max. 230 m

Housing pressure 25 bar

Certificates *

GEA Hilge CONTRA II Adapta / Adapta-tronic on Vertical Stand

12

103

4

109

.5

e5

a1

304

- f

2 k

3

u

f2

DN

375 h3

h2

DN

DN

b

S

SD

(1)

(1)

Øp6

P.102.0000.0043R1

490

490

75

400 4

00

14

Top view(w/o terminal box)

Standard tronic

P2[kW]

IEC- size

b [mm]

p6 [mm]

k3(1)

[mm]u(1)

[mm]k3

(1) [mm]

u(1) [mm]

Weight [kg]

4.0 112M 0 250 380 185 334 201 135

5.5 132S 20 300 450 205 365 201 162

7.5 132S 20 300 450 205 389 237 171

11.0 160M 51 350 570 260 406 237 198

15.0 160M 51 350 570 260 471 308 206

18.5 160L 51 350 580 260 515 308 227

22 160L On request

2-pole

Dimensions depend on the casing size (DNS, DND, a1, h2, h3, e1, e5). See table of connections.(1) Motor dimensions depend on the motor manufacturer and execution. The shown motor dimensions indicate the size for the standard motor.Weight: net-weight without packaging

* registered for recertification

Page 126: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

126 · GEA Hilge CONTRA II, 50 / 50 (175 × 6) 2-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 127: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 127

2

GEA Hilge CONTRA II, 50 / 50 (175 × 6) 3-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 128: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

128 · GEA Hilge CONTRA II, 50 / 50 (175 × 6) 4-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 129: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 129

2

GEA Hilge CONTRA II, 50 / 50 (175 × 6) 5-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 130: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

130 · GEA Hilge CONTRA II, 65 / 65 (175 × 6) 2-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 131: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 131

2

GEA Hilge CONTRA II, 65 / 65 (175 × 6) 3-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 132: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

132 · GEA Hilge CONTRA II, 65 / 65 (175 × 6) 4-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 133: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 133

2

GEA Hilge CONTRA II, 65 / 65 (175 × 6) 5-stage, 50 Hz

The flow charts are based on water, temperature 20 °C

Page 134: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

134 · GEA Hilge CONTRA II, 50 / 50 (175 × 6) 2-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 135: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 135

2

GEA Hilge CONTRA II, 50 / 50 (175 × 6) 3-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 136: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

136 · GEA Hilge CONTRA II, 50 / 50 (175 × 6) 4-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 137: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 137

2

GEA Hilge CONTRA II, 50 / 50 (175 × 6) 5-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 138: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

138 · GEA Hilge CONTRA II, 65 / 65 (175 × 6) 2-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 139: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 139

2

GEA Hilge CONTRA II, 65 / 65 (175 × 6) 3-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 140: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

140 · GEA Hilge CONTRA II, 65 / 65 (175 × 6) 4-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 141: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA GEA Hilge CONTRA II

· 141

2

GEA Hilge CONTRA II, 65 / 65 (175 × 6) 5-stage, 60 Hz

The flow charts are based on water, temperature 20 °C

Page 142: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

142 ·

GEA Appendix

Centrifugal PumpsInquiry Sheet

GEA Hygienic Pumps

INQUIRY SHEET · CENTRIFUGAL PUMPS 1/2

Contact Data

Company:

Contact Person: E-mail:

Phone: Country:

Preferred Range

VARIPUMP SMARTPUMP No requirement

Liquid Data

*Liquid: Solids: No Yes:

*Liquid temperature [°C / °F]: Kind of solids:

*Density [kg/dm³]: Size of solids [mm]:

*Viscosity [mPas]: Abrasive: No Yes

Concentration [%]:

Operating Conditions

*Duty point 1 *Flow [m3/h / gpm]: *Head [m lc]:

Duty point 2 Flow [m3/h / gpm]: Head [m lc]:

End-suction pump: Self-priming pump:

Inlet pressure (NPSHa) [m]: Suction head [m]:

Vacuum at inlet: No Yes: Gas content: No < 5 % > 5 %

Vacuum, abs. [mbar]:

System pressure [bar]:

Cleaning / Sterilization

CIP: No Yes: SIP: No Yes:

CIP Temperature [°C / °F]: SIP Temperature [°C / °F]:

CIP Flow [m3/h / gpm]: SIP Duration [min]:

CIP Head [m Fls]:

Execution and Design

Pump in Bloc version with motor Combi foot Motor foot

Pump in long coupled version with base plate and standard motor On Trolley Horizontal

With stainless steel motor shroud Cast iron foot Vertical

3-A stainless steel adjustable feet Stainless steel foot Vertical with stainless steel stand

Pump execution

*Connection Type Connection Size DNI /DNO:

Tri Clamp (DIN 32676) ANSI Flange DIN 11851 Other:

Drainable: No Yes DIN 11853-2 / 11864-2 Other:

Page 143: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 143

GEA Appendix

Centrifugal Pumps

GEA Hygienic Pumps

INQUIRY SHEET · CENTRIFUGAL PUMPS 2/2

* Fields marked with an asterisk are mandatory for a pump selection

Surface Roughness Ferrite Content Shaft Seal

Not specified Not specified Single mechanical seal

Ra ≤ 3.2 μm Fe < 1% Flushed mechanical seal

Ra ≤ 0.8 μm

Ra ≤ 0.4 μm

Material Shaft Seal Elastomer

Carbon / Stainless Steel EPDM

SiC / SiC FKM (Viton)

Carbon / SiC other:

other:

Motor Data

Power supply: Motor speed [1/min]:

3~ 400V / 50 Hz 3~ 460V / 60 Hz PTC-Thermistors: No Yes

3~ 200V / 50 Hz 3~ 200V / 60 Hz 2 wire-Thermistors: No Yes

EXP Motor No Yes:

Temperature class: Division:

Ambient Temperature [°C / °F]: Group:

Class:

Certificates / Documentation

3-A Sanitary Standard certification FDA declaration of conformity

Inspection certificate 3.1 acc. to DIN EN 10204 Surface roughness test report

Test report 2.2 acc. to DIN EN 10204 Delta ferrite test report

EHEDG certification

Further certificates and documentation:

Further Information

Variable speed drive No Yes: Explosion protection No Yes

External frequency converter (not on motor) ATEX No Yes:

Integrated frequency converter (on motor)

other: 3~ 380V / 60 Hz

Ex-Zone:

Temperature class:

Ambient temperature [°C / °F]:

V1.0-2018

Inquiry Sheet

Page 144: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

144 ·

GEA

Description of Certificates and Test Reports

2.1 Works certificate according to DIN EN 10204: Declaration of the compliance with the order. This certificate is issued by the manufacturer.

2.2Test report according to DIN EN 10204: Declaration of the compliance with the order under specification of the results of non specific tests. This certificate is issued by the manufacturer.

3.1

Inspection certificate 3.1 according to DIN EN 10204: Declaration of the compliance with the order under specification of the results of spcific tests. This certificate is issued by an authority which is independent of manufacturing and is validated by the manufacturers authorised inspection representative

3-A3-A Sanitary Standards, Inc. (3-A SSI) is an independent, non-profit corporation dedicated to advancing hygienic equipment design for the food, beverage, and pharmaceutical industries.

AS-i Actuator Sensor interface. BUS system for the lowest field level.

ASME-BPE Standard of the ASME's – bioprocessing equipment association

ATEXAtmosphères Explosibles. ATEX comprises the directives of the European Union in the area of explosion protection. For one thing, this is the ATEX equipment directive 94/9/EC, for another, the ATEX workplace directive 1999/92/EC.

cCSAus Test of a product by CSA according to applicable safety standards in Canada and the USA.

CE Conformité Européenne. By affixing the CE mark, the manufacturer confirms that the product complies with the European directives applicable to the specific product.

CSACanadian Standards Association. A non-governmental Canadian organization which issues standards as well as checking and certifying the safety of products. It is now globally active.

cULus Test of a product by UL according to applicable safety standards in Canada and the USA.

DIN EN ISO 9001:2015This norm is the basis for a multitude of varied organizations in different industries worldwide for quality assurance and quality management. It is the most widespread standards of ISO (International Organisation for Standardization).

EACEuroasion conformity. The symbol is used similar to the European CE mark. The manufacturer or supplier confirms that the machine has passed all necessary compliance procedures in ohne of the Member States of the customs union.

EG 1935/2004Materials in contact with the product used in pumps from GEA Hilge are in accordance with EC regulation 1935/2004. This defines a general framework for materials and objects intended to come into contact with foodstuffs.

EHEDGEuropean Hygienic Engineering & Design Group. European supervisory authority for foodstuffs and pharmaceuticals. This authority issues approvals and certificates for products and materials that are used in the foodstuffs and pharmaceuticals industries.

FDAFood and Drug Administration. US supervisory authority for foodstuffs and pharmaceuticals. This authority issues approvals and certificates for products and materials that are used in the foodstuffs and pharmaceuticals industries.

QHD

The QHD (Qualified Hygienic Design) is a two-phase testing system for the hygienic design and cleanability of components, machinery and plants for aseptic or sterile applications. The system ensures that all surfaces can be cleaned in place (CIP). The QHD symbol is used by manufacturers to indicate compliance with the QHD criteria.

UL Underwriters Laboratories. An organization founded in the USA for checking and certifying products and their safety.

USP Class VIThe United States Pharmacopeial Convention (USP) is a scientific nonprofit organization that sets standards to help protecting public health. Class VI administer tests and impacts of material and their substances on animal and human tissues.

Appendix

Page 145: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 145

GEA

Abbreviations and Terms

Abbreviation Explanation

°C Degrees Celsius, unit of measurement for temperature

°F Degrees Fahrenheit, unit of measurement for temperature

3D Three-dimensional

AAmpere, unit of measurement of current intensity or Output, term used in automation

AC Alternating Current

ADI free All elastomer compounds are free of animal-derived ingredients

AISI American Iron and Steel Institute, association of the American steel industry

ANSI American National Standards Institute, American body for standardizing industrial processes

approx. approximately

AS-i Actuator Sensor interface, standard for fieldbus communication

ASME American Society of Mechanical Engineers, professional association of mechanical engineers in the USA

ASME-BPE Standard of the ASME's – bioprocessing equipment association

ATEX Atmosphères Explosibles, synonymous with the directives of the European Union for potentially explosive areas

bar Unit of measurement for pressure. All pressure values [bar/psi] refer to positive pressure [barg / psig], unless specifically stated otherwise.

barg Unit of measurement for pressure relative to atmospheric pressure

CAN Controller Area Network; asynchronous serial bus system

CE Conformité Européenne, administrative symbol for the free movement of industrial products

CIP Cleaning In Place, designates a process for cleaning technical process systems.

CRNCanadian Registration Number,is issued by a Canadian Jurisdiction and covers pressure vessels, fittings, or pressure piping. It is a necessary authorization allowing these components to be in operation in Canada.

CSA Canadian Standards Association, a non-governmental Canadian Standardization organization

Cv The Cv value corresponds to the water flow rate through a valve (in US gal / min) at a pressure differential of 1 PSI and a water temperature of 5 °C to 30 °C. kv = 14,28 Cv (USA).

Cvs The Cv values of a valve at nominal stroke (100 % opening) is designated the Cvs value.

dB Decibel, one tenth of a bel, named after Alexander Graham Bell and used for identifying levels and dimensions

DC Direct Current

DIN Deutsches Institut für Normung e. V. Standardization organization in the Federal Republic of Germany, DIN = synonym for standards issued by the organization

Appendix

Page 146: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

146 ·

GEA

Abbreviations and Terms

Abbreviation Explanation

DIP Dual Inline Package, design of a switch

DN Diameter Nominal, DIN nominal width

Device Net Network system used in the automation industry to interconnect control devices for data exchange

E Input, term used in automation

EAC Certification of technical confirmity from the customs union of Russia/Balarus/Kazakhstan

Pressure Equipment Directive 97/23/EC

Directive of the European Parliament and the Council Directive for layout and conformity evaluation for pressure equipment and assemblies with a maximim pressure (PS) of more than 0.5 bars.

EG No. 1935/2004 Regulation of the European Parliament which lays down common rules for materials which come, or may come, into contact with food, either directly or indirectly.

EHEDG European Hygienic Engineering and Design Group. Consortium of equipment manufacturers, food industries, research institutes as well as public health authorities

EN European standard, rules of the European Committee for Standardization

EPDM Ethylene propylene diene rubber, acronym acc. to DIN / ISO 1629

Ex Synonym for ATEX

FDA Food and Drug Administration, official foodstuffs monitoring in the United States

FEM calculation Finite Element Method; calculation process for simulating solids

FKM Fluorinated rubber, acronym acc. to DIN / ISO 1629

GOSTGosudarstvennyy Standart, Certification of conformity for components according to standards and regulations of the Russian Federation

H Henry, unit of measurement for inductance

HNBR Hydrated acrylonitrile butadiene rubber, acronym acc. to DIN / ISO 1629

Hz Hertz, unit of frequency named after Heinrich Hertz

I Formula symbol for electrical current

IEC International Electrotechnical Commission, international standardization organization for electrical and electronic engineering

IP Ingress Protection / International Protection, index of protection class acc. to IEC 60529

IPS Iron Pipe Size, American pipe dimension

ISA International Society of Automation, international US organization of the automation industry

ISOInternational Organization for Standardization, international organization that produced international standards, ISO = synonym for standards from the organization

kg Kilogram, unit of measurement for weight

Kv The Kv value corresponds to the water flow rate through a valve (in m³ / h) at a pressure differential of 0.98 bar and a water temperature of 5 °C to 30 °C.

Appendix

Page 147: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

· 147

GEA

Abbreviations and Terms

Abbreviation Explanation

Kvs The Kv values of a valve at nominal stroke (100 % opening) is designated the Kvs value

L Conductive

LED Light-Emitting Diode

mm Millimeter, unit of measurement for length

MMetric, system of units based on the meter or Mega, one million times a unit

m3/h Cubic meters per hour, unit of measurement for volumetric flow

max. Maximum

NAMUR Standardization working association for measuring and control technology in the chemical industry, synonym for the interface type of the organization, especially for potentially explosive atmospheres

NC Normally Closed; valve or solenoid valve control which is closed in idle status

NO Normally Open; valve or solenoid valve control which is open in idle status

NOT-element Logic element, NOT gate

NPN Signal transmission against reference potential, current-consuming

NPT National Pipe Thread, US thread standard for self-sealing pipe fittings

OD Outside Diameter, pipe dimension

ODVA Open DeviceNet Vendor Association, global association for network standards

PA 12/L Polyamide

Pg Armoured thread

PN Nominal pressure for pipeline systems according to EN 1333,rated pressure in bar at room temperature (20 °C)

PNP Signal transmission against reference potential, current-supplying

PPO Polyphenylene oxide, thermoplastic material

PS Maximum permitted operating pressure at which the components can operate safely at maximum allowable temperature (TS)

psi Unit of measurement for pressure, pound-force per square inch, 1 psi = 6894.75 Pa. All pressure values [bar/psi] refer to positive pressure [barg / psig], unless specifically stated otherwise.

psig Unit of measurement for pressure relative to atmospheric pressure

PV Solenoid valve

Ra in μm Average roughness value, describes the roughness of a technical surface

International Protection-Code IP67, IP66, IP69K

Classifies and rates the degree of protection provided against intrusion dust, accidental contact, and water

Appendix

Page 148: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

148 ·

GEA

Abbreviations and Terms

Abbreviation Explanation

SES GEA Tuchenhagen control head for Ex areas, control top system of GEA Tuchenhagen

SET-UP Self-learning installation, the SET-UP procedure carries out all necessary settings for generating messages during commissioning and maintenance.

SIP Sterilization in Place,refers to a process for cleaning technical process systems

SMS Svensk Mjölk Standard, Scandinavian pipe dimension

SW Indicates the size of a tool spanner, “Schlüsselweite”

TA-LuftVDI 2440

If a product is certified according to TA Luft it meets the requirements for proof of high grade performance according to TA Luft of 1.0x 10-4 mbar x l / (s x m) at service conditions under the VDI guideline 2440. The product will hence be tested for tightness.

TS Maximum permitted operating temperature

UL Underwriters Laboratories, a certification organization established in the USA

USP Class VIThe United States Pharmacopeial Convention (USP) is a scientific nonprofit organization that sets standards to help protecting public health. Class VI administer tests and impacts of material and their substances on animal and human tissues.

UV Ultraviolet, ultraviolet radiation is a wavelength of light

V Volt, unit of measurement for voltage

VMQ High-polymer vinyl methyl polysiloxane, silicone rubber, MVQ = synonym

W Watt, unit of measurement for power

Y Control air connection for the working cylinder, designation from pneumatic systems

μ Micro, one millionth of a unit

Ω Ohm, the unit of electrical resistance named after Georg Simon Ohm

Appendix

Page 149: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis
Page 150: GEA Hilge CONTRA€¦ · GEA ·Introduction to GEA Flow Components 7 Cleaning Technology Index, orbital, rotating and static cleaners in a complete range, developed with special emphasis

GEA is a global technology company with multi-billion euro sales operations in more than 50 countries. Founded in

1881 the company is one of the largest providers of innovative equipment and process technology. GEA is listed in the

STOXX® Europe 600 Index. In addition, the company is included in selected MSCI Global Sustainability Indexes.

We live our values.Excellence • Passion • Integrity • Responsibility • GEA-versity

GEA

Hilg

e C

ON

TRA

1

2/18

©

GEA

Hilg

e N

iede

rlass

ung

der

GEA

Tuc

henh

agen

Gm

bH. A

ll rig

hts

rese

rved

.

Subj

ect

to m

odifi

catio

ns. P

rinte

d in

Ger

man

y.

GEA Germany

GEA Hilge

Niederlassung der GEA Tuchenhagen GmbH

Hilgestraße 37–47

55294 Bodenheim, Germany

Tel +49 6135 7016-0

Fax +49 6135 1737

[email protected]

gea.com