gendrive series 2000 gx6 - arbasarbas.co.id/wp-content/uploads/2016/12/32310311_mtu_gen...gendrive...
TRANSCRIPT
Gendrive
Series 2000 Gx6 for Power Generation Standard Backup Applicationswith water-to-air charge air cooling
Power. Passion. Partnership.
Dimensions and Masses
Engine Dimensions(LxWxH)mm(in) Mass,drykg(lbs)
12V 1885x1546x1420(74x61x56) 2710(5975)
16V 2235x1568x1420(88x62x56) 3180(7011)
Alldimensionsareapproximate,forcompleteinformationrefertotheinstallationdrawing.
EngineModel
Bore/stroke mm(in) 135/156(5.3/6.15)
Cylinderconfiguration 90°V
Displacement/cylinder l(cuin) 2.23(136)
Displacement,total l(cuin) 12V:26.76(1633),16V:35.68(2177)
Fuelspecification EN590,GradeNo.1-D/2-D(ASTMD975-00)
Applicationgroup Powerdefinition
StandbyPower(3D) Emergencyservice,fuelstoppower, Loadfactor:≤85%,Operatinghours:max.500/year,
IFN Overload:Fuelstoppower(IFN)
PowerdefinitionaccordingtoISO3046(ratingsalsocorrespondtoSAEJ1995andSAEJ1349standardconditions).ConsultyourMTUdistributor/dealerfortheratingthatwillapplytoyourspecificapplication.Rated power is without fan drive. The power consumption of any fan drive has to be deducted during designing of a generator set.
2IStandardBackupApplications
Standby Power (3D)
Engine Type Rated power kW (bhp) at 1500 rpm (50Hz) Optimization
12V2000G76S 890(1194) x x x
12V2000G86S 987(1324) x x x
16V2000G76S 1097(1471) x x x
16V2000G86S 1371(1839) x x x
Fanpowerrequirementnotconsidered
Fuel
con
sum
ptio
n op
timiz
ed
Engine Type Rated power kW (bhp) at 1800 rpm (60Hz) Optimization
US
EPA
Sta
tiona
ry
EMER
G T
ier
2 (4
0 C
FR 6
0)
US
EPA
Non
road
Tie
r 2
com
plia
nt (4
0 C
FR 8
9)
193
3 19 referencetoemissionlevelinpricelist
MTU Friedrichshafen GmbH I MTU Asia Pte Ltd I MTU America Inc.Rolls-RoycePowerSystemsCompanies
www.mtu-online.com
StandardEquipment
StartingSystem 1electricstarter(24VDC/2-pole)
FuelSystem Electronicallycontrolledcommon-railhigh-pressureinjectionsystem,dualenginemountedfuelfilters
LubeOilSystem Forcedfeedlubricationsystemwithpistoncooling,lubeoilcirculationpump,lubeoilfilter,lubeoilheatexchanger
CombustionAirSystem 2exhaustturbochargers,water-to-airintercoolerintegratedinradiator
CoolingSystem Coolantcirculationpumpandcoolantthermostatforjacketwatercircuit
EngineMounting Setofenginemountingbracketsforresilientmount
EngineManagement IntegratedelectronicenginecontrolandmonitoringsystemADEC,customerinterface„SmartConnect“
OptionalEquipment
StartingSystem Compressedair,redundantstartingsystem:electric/electric;air/air;electric/air
FuelSystem Fuelpre-filter,specialfuelpre-filterwithwaterseparator
CombustionAirSystem Heavydutyairfilters
CoolingSystem Enginemountedfandrive
EngineMounting Resilientenginemounts(rubberelements),rigidenginemounting
AuxiliaryPowerSupply Batterychargingalternator
Referenceconditions:–Intake-airtemperature:25°C(77°F)–Ambientairpressure:1bar(14.5psi)–Altitudeabovesealevel:100m(328ft)
Subjecttochangewithoutnotice.Customizationpossible.Enginesillustratedinthisdocumentmayfeatureoptionsnotfittedasstandard.
Subj
ectt
och
ange
.|3
2310
311
|Ed
ition
01/
16|
EN
C2
016-
03.