general abbreviations ductwork...double line duct ring 90° tap take-off duct mtd. sidewall...

8
LINEAR FEET KILOWATT MEZZANINE MECHANICAL MOTOR CONTROL CENTER LEAVING WATER TEMPERATURE LINEAR DIFFUSER LEAVING AIR TEMPERATURE NUMBER MOUNTED MINIMUM OUTSIDE AIR POUNDS PER CUBIC FOOT OUTSIDE AIR INTAKE PRESSURE DROP OUTSIDE DIAMETER NOT TO SCALE NOT IN CONTRACT NOT APPLICABLE OUTSIDE AIR UNIT MANUFACTURER REQUIRED RETURN FAN REVOLUTIONS PER MINUTE POUNDS PER SQUARE INCH GAUGE RETURN REGISTER REQUIREMENTS RELATIVE HUMIDITY RETURN GRILLE SUPPLY FAN SQUARE SCREEN SUPPLY SQUARE FEET TEMPERATURE TRANSFER FAN STAINLESS STEEL SUPPLY REGISTER SLIDE GATE DAMPER SPECIFICATIONS SUPPLY GRILLE SCHEDULE TYPICAL TRANSFER WET BULB TEMPERATURE WIRE MESH SCREEN VOLUME DAMPER UNDERCUT DOOR TOP OF PIPE TOP OF DUCT TRANSFER GRILLE PLUMBING POUNDS PER SQUARE INCH DIFFERENTIAL POUNDS PER SQUARE INCH ABSOLUTE INCHES LOUVER IN LF LD LAT KW LUVR LWT MEZZ MECH MCC N/A MTD MIN NO. NTS NIC OD OAI OAU PD PCF OA MF'R GENERAL ABBREVIATIONS ADDITIONAL AIR FILTER ARCHITECT BUILDING BOTTOM OF DUCT BRAKE HORSEPOWER BOTTOM OF PIPE ACCESS PANEL ACOUSTICAL DUCT LINER AIR CONDITIONING ABOVE FINISHED FLOOR ACCESS DOOR CEILING CENTERLINE COLUMN CONCRETE CLEAN-OUT CUBIC FEET CUBIC FEET PER MINUTE CEILING FAN CEILING DIFFUSER CONNECTION CONTRACTOR AC ADD'L ADL AF AD ARCH AP AFF BOP BOD BLDG BHP CFM CF CD CLG CLR CL COL CONC CO CONTR CUF CONN CLS CLOSED LOOP (HEAT PUMP) WATER SUPPLY CLOSED LOOP (HEAT PUMP) WATER RETURN RETURN RELIEF ROOM STEEL PSID PSIA PSIG RET REQ'S REQ'D RG RH RLF RR RM RPM RF SF SG SCR SQ SGD SPECS SS SR STL TF TEMP SUP SQFT SCH VENT TG TOP TOD UC TYP TR VD WB WMS V DIFFUSER DIAMETER EACH DOWN DIMENSION EFFICIENCY EMERGENCY ELEVATION ELECTRICAL ENTERING AIR TEMPERATURE EXHAUST REGISTER EXHAUST FAN EXHAUST GRILLE DRY BULB TEMPERATURE EXHAUST FAN BOX FREE AREA EXPANSION FIBERGLASS FLEXIBLE FEET FURNISHED GAUGE ENTERING WATER TEMPERATURE FEET PER MINUTE EXTERNAL STATIC PRESSURE DIFF DIA DB EAT EA DN DIM EF EG EFF ER EMER ELEV ELEC EXH EWT FA FB EXP FLEX FG FT FURN GA FPM ESP GALVANIZED HEAD HEIGHT HOUR HERTZ GRADE (GROUND) GENERAL CONTRACTOR HORSEPOWER HEAT PUMP UNIT HEATING & VENTILATING UNIT HEAT EXCHANGER GC GALV GRD HGT HD HP HP HR HV HZ HX PLBG TEMPERATURE SENSOR OR THERMOSTAT DOUBLE LINE SINGLE LINE RISE/DROP TAP 45° R RISE/DROP TAKE-OFF EXHAUST SUPPLY/RETURN/ RISE OR DROP /EXHAUST SUPPLY/RETURN OFFSET HORIZONTAL DUCT DOWN RETURN/EXHAUST DUCT UP RETURN/EXHAUST SINGLE LINE STANDARD RADIUS ELBOW ( R = W ) SUPPLY DUCT DOWN SUPPLY DUCT UP w SUPPLY W/ BRANCH DAMPERS SPLIT TAKE-OFF EXHAUST SUPPLY / RETURN OR DUCTWORK DOUBLE LINE DUCT RING 90° TAP TAKE-OFF DUCT MTD. SIDEWALL REG./GRILLE RETURN/EXHAUST CONVERGE BULLHEAD 8 FEET MAXIMUM FLEXIBLE DUCT OPEN END DUCT W/ 1/4"x1/4" WMS RING DUCT TAKEOFF TO GOOD FOR SUPPLY BULLHEAD SPLIT HARD CEILING TAKEOFF TO DIFF/GRILLE DUCT MTD. DIFF/GRILLE OR ELBOW DUCT MTD. DIFF/GRILLE CEILING LINED DUCT ACOUSTICALLY BACKDRAFT DAMPER VERTICAL FIRE DAMPER OUTSIDE AIR, RETURN, OR EXHAUST AIR FLOW HORIZONTAL FIRE DAMPER MANUAL VOLUME DAMPER SUPPLY AIR FLOW LOUVERED DOOR REFER TO ARCH. DWGS. STANDARD 4-WAY BLOW SUPPLY DIFFUSER STANDARD EXHAUST REGISTER DUCT OR EQUIPMENT TO BE REMOVED BACK DRAFT DAMPER BDD FSD FIRE SMOKE DAMPER W/ACCESS DOORS SD SMOKE DAMPER GRAVITY DAMPER GD ELECTRIC CABINET HEATER ECH FIRE SMOKE DAMPER CONSTANT AIR VOLUME CAV VARIABLE AIR VOLUME VAV FSD SMOKE DAMPER SD EXISTING (E) OUTSIDE WALL FIRE SMOKE DAMPER OFSD STANDARD RETURN REGISTER Sheet Title: Sheet Number: Date: Issued for: 05-19-20 OWNER REVIEW OAKRIDGE MANOR NURSING AND REHABILITATION NSA Architects, Engineers, Planners Copyright C 2020 Project Number: Project Title: Client: DRAWN DESIGNED CHECKED APPROVED 06-26-20 ISSUED FOR PERMITS CONSULTING ENGINEERS MacMILLAN ASSOCIATES BAY CITY, MICHIGAN 48706 714 EAST MIDLAND STREET www.macmillanassociates.com (989) 894-4300 F(989) 894-9930 06-05-20 95% REVIEW SYMBOLS MECHANICAL M-001 DM RAM RAM RAM 216105.00 PIONEER HEALTH CARE MANAGEMENT, INC. DSD C>B-250C@ C>A-250C@ DUCT SMOKE DETECTOR RETURN OR EXHAUST AIR GRILLE - TYPE "B", 250 CFM SUPPLY AIR DIFFUSER - TYPE "A", 250 CFM HORIZONTAL FIRE DAMPER VERTICAL SMOKE DAMPER VERTICAL FIRE DAMPER V G ST ST SAN SAN DOMESTIC HOT WATER RETURN PIPING DOMESTIC HOT WATER PIPING DOMESTIC COLD WATER PIPING VENT PIPING NATURAL GAS PIPING SANITARY PIPING BELOW FLOOR OR GRADE SANITARY PIPING ABOVE FLOOR STORM PIPING BELOW FLOOR OR GRADE STORM PIPING ABOVE FLOOR FP FIRE PROTECTION PIPING GRISWOLD AUTOMATIC FLOW LIMITING VALVE THREE WAY CONTROL VALVE (PNEUMATIC) TWO WAY CONTROL VALVE (PNEUMATIC) FLEXIBLE CONNECTION FLOW ARROW ISOLATION GATE VALVE CHECK VALVE UNION CAP REDUCER EXTERIOR WALL HYDRANT VALVE IN RISER PRESSURE REGULATING VALVE TEMPERATURE & PRESSURE RELIEF VALVE INLINE PUMP FS FLOW SWITCH PRESSURE GAUGE W/COCK MANUAL AIR VENT AUTOMATIC AIR VENT PIPE ANCHOR PIPE GUIDE WATER PIPING LOCATED OUTSIDE OF BUILDING W HORIZONTAL SMOKE DAMPER SLOT DIFFUSER S S HORIZONTAL COMBINATION FIRE/SMOKE DAMPER VERTICAL COMBINATION FIRE/SMOKE DAMPER MOTORIZED DAMPER MANUAL DAMPER RF REFRIGERANT LINE PRESSURE SENSOR OR SWITCH PS THERMOMETER PRESSURE REGULATING OR REDUCING VALVE T SERVICE SINK FLUSH TANK WATER CLOSET FLUSH VALVE FLOOR MOUNTED FLUSH VALVE WALL MOUNTED URINAL LAVATORY OR SINK FLOOR SINK THERMOSTAT OR WALL SENSOR FLOOR DRAIN ROOF DRAIN BELOW ROOF (FLOOR PLAN) ROOF DRAIN ON ROOF (ROOF PLAN) EXHAUST FAN WITH FAN ABOVE (FLOOR PLAN) EXHAUST FAN ON ROOF (ROOF PLAN) CO UP TO GRADE CO ABOVE FLOOR CO UP TO FLOOR SAN SAN SAN ELBOW DROPPING DOWN ELBOW RISING UP TEE WITH PIPE DOWN TEE WITH PIPE UP SECONDARY EMERGENCY DRAINAGE PIPING SED 140° HOT WATER FOR KITCHEN THREE WAY CONTROL VALVE (ELECTRIC) TWO WAY CONTROL VALVE (ELECTRIC) KITCHEN MASTER GAS VALVE GAS REGULATOR EX. VERTICAL FIRE DAMPER EX. HORIZONTAL FIRE DAMPER CO2 CARBON DIOXIDE SENSOR MISC. EQUIP. COND DRAIN PIPING CD INTERIOR HOSE BIB DUCT PRESSURE SENSOR PRV REDUCED PRESURE BACKFLOW PREVENTER RPBP ACID VENT PIPING AV 140° RAIN CONDUCTOR RC \\maibc19\drawings\16-NSA\2019-1620 Oakridge Manor Nursing Home Mechanical and Structural Review\DOWNLOADED CAD Files\Mechanical\M-001.dwg, Model, 7/15/2020 9:11:57 AM, smaguire, 12:12 7/15/2020 MAI # 2019-1620

Upload: others

Post on 27-Sep-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GENERAL ABBREVIATIONS DUCTWORK...double line duct ring 90° tap take-off duct mtd. sidewall reg./grille return/exhaust converge bullhead 8 feet maximum flexible duct open end duct

LINEAR FEET

KILOWATT

MEZZANINE

MECHANICAL

MOTOR CONTROL CENTER

LEAVING WATER TEMPERATURE

LINEAR DIFFUSER

LEAVING AIR TEMPERATURE

NUMBER

MOUNTED

MINIMUM

OUTSIDE AIR

POUNDS PER CUBIC FOOT

OUTSIDE AIR INTAKE

PRESSURE DROP

OUTSIDE DIAMETER

NOT TO SCALE

NOT IN CONTRACT

NOT APPLICABLE

OUTSIDE AIR UNIT

MANUFACTURER

REQUIRED

RETURN FAN

REVOLUTIONS PER MINUTE

POUNDS PER SQUARE INCH GAUGE

RETURN REGISTER

REQUIREMENTS

RELATIVE HUMIDITY

RETURN GRILLE

SUPPLY FAN

SQUARE

SCREEN

SUPPLY

SQUARE FEET

TEMPERATURE

TRANSFER FAN

STAINLESS STEEL

SUPPLY REGISTER

SLIDE GATE DAMPER

SPECIFICATIONS

SUPPLY GRILLE

SCHEDULE

TYPICAL

TRANSFER

WET BULB TEMPERATURE

WIRE MESH SCREEN

VOLUME DAMPER

UNDERCUT DOOR

TOP OF PIPE

TOP OF DUCT

TRANSFER GRILLE

PLUMBING

POUNDS PER SQUARE INCH DIFFERENTIAL

POUNDS PER SQUARE INCH ABSOLUTE

INCHES

LOUVER

IN

LF

LD

LAT

KW

LUVR

LWT

MEZZ

MECH

MCC

N/A

MTD

MIN

NO.

NTS

NIC

OD

OAI

OAU

PD

PCF

OA

MF'R

GENERAL ABBREVIATIONS

ADDITIONAL

AIR FILTER

ARCHITECT

BUILDING

BOTTOM OF DUCT

BRAKE HORSEPOWER

BOTTOM OF PIPE

ACCESS PANEL

ACOUSTICAL DUCT LINER

AIR CONDITIONING

ABOVE FINISHED FLOOR

ACCESS DOOR

CEILING

CENTERLINE

COLUMN

CONCRETE

CLEAN-OUT

CUBIC FEET

CUBIC FEET PER MINUTE

CEILING FAN

CEILING DIFFUSER

CONNECTION

CONTRACTOR

AC

ADD'L

ADL

AF

AD

ARCH

AP

AFF

BOP

BOD

BLDG

BHP

CFM

CF

CD

CLG

CLR

CL

COL

CONC

CO

CONTR

CUF

CONN

CLSCLOSED LOOP (HEAT PUMP) WATER SUPPLY

CLOSED LOOP (HEAT PUMP) WATER RETURN

RETURN

RELIEF

ROOM

STEEL

PSID

PSIA

PSIG

RET

REQ'S

REQ'D

RG

RH

RLF

RR

RM

RPM

RF

SF

SG

SCR

SQ

SGD

SPECS

SS

SR

STL

TF

TEMP

SUP

SQFT

SCH

VENT

TG

TOP

TOD

UC

TYP

TR

VD

WB

WMS

V

DIFFUSER

DIAMETER

EACH

DOWN

DIMENSION

EFFICIENCY

EMERGENCY

ELEVATION

ELECTRICAL

ENTERING AIR TEMPERATURE

EXHAUST REGISTER

EXHAUST FAN

EXHAUST GRILLE

DRY BULB TEMPERATURE

EXHAUST

FAN BOX

FREE AREA

EXPANSION

FIBERGLASS

FLEXIBLE

FEET

FURNISHED

GAUGE

ENTERING WATER TEMPERATURE

FEET PER MINUTE

EXTERNAL STATIC PRESSURE

DIFF

DIA

DB

EAT

EA

DN

DIM

EF

EG

EFF

ER

EMER

ELEV

ELEC

EXH

EWT

FA

FB

EXP

FLEX

FG

FT

FURN

GA

FPM

ESP

GALVANIZED

HEAD

HEIGHT

HOUR

HERTZ

GRADE (GROUND)

GENERAL CONTRACTOR

HORSEPOWER

HEAT PUMP UNIT

HEATING & VENTILATING UNIT

HEAT EXCHANGER

GC

GALV

GRD

HGT

HD

HP

HP

HR

HV

HZ

HX

PLBG

TEMPERATURE SENSOR OR THERMOSTAT

DOUBLE LINESINGLE LINE

RISE/DROP

TAP

45°

R

RISE/DROP

TAKE-OFF

EXHAUST

SUPPLY/RETURN/

RISE OR DROP

/EXHAUST

SUPPLY/RETURN

OFFSET

HORIZONTAL

DUCT DOWN

RETURN/EXHAUST

DUCT UP

RETURN/EXHAUST

SINGLE LINE

STANDARD RADIUS ELBOW

( R = W )

SUPPLY DUCT DOWN

SUPPLY DUCT UP

w

SUPPLY

W/ BRANCH DAMPERS

SPLIT TAKE-OFF

EXHAUST

SUPPLY / RETURN

OR

DUCTWORK

DOUBLE LINE

DUCT

RING

90°

TAP

TAKE-OFF

DUCT MTD.

SIDEWALL

REG./GRILLE

RETURN/EXHAUST

CONVERGE

BULLHEAD

8 FEET MAXIMUM

FLEXIBLE DUCT

OPEN END

DUCT W/

1/4"x1/4" WMS

RING DUCT

TAKEOFF TO

GOOD FOR

SUPPLY

BULLHEAD SPLIT

HARD

CEILING

TAKEOFF

TO

DIFF/GRILLE

DUCT MTD.

DIFF/GRILLE

OR

ELBOW

DUCT MTD.

DIFF/GRILLE

CEILING

LINED DUCT

ACOUSTICALLY

BACKDRAFT DAMPER

VERTICAL FIRE DAMPER

OUTSIDE AIR, RETURN, OR EXHAUST AIR FLOW

HORIZONTAL FIRE DAMPER

MANUAL VOLUME DAMPER

SUPPLY AIR FLOW

LOUVERED DOOR REFER TO ARCH. DWGS.

STANDARD 4-WAY BLOW SUPPLY DIFFUSER

STANDARD EXHAUST REGISTER

DUCT OR EQUIPMENT

TO BE REMOVED

BACK DRAFT DAMPERBDD

FSD FIRE SMOKE DAMPER W/ACCESS DOORS

SD SMOKE DAMPER

GRAVITY DAMPERGD

ELECTRIC CABINET HEATERECH

FIRE SMOKE DAMPER

CONSTANT AIR VOLUMECAV

VARIABLE AIR VOLUMEVAV

FSD

SMOKE DAMPER

SD

EXISTING(E)

OUTSIDE WALL FIRE SMOKE DAMPER

OFSD

STANDARD RETURN REGISTER

Sheet Title:

Sheet Number:

Date: Issued for:

05-19-20 OWNER REVIEW

OAKRIDGE MANOR

NURSING AND

REHABILITATION

NSA Architects, Engineers, Planners

Copyright C 2020

Project Number:

Project Title:

Client:

DRAWN DESIGNED

CHECKED APPROVED

06-26-20 ISSUED FOR PERMITS

CONSULTING ENGINEERSMacMILLAN ASSOCIATES

BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET

www.macmillanassociates.com(989) 894-4300 F(989) 894-9930

06-05-20 95% REVIEW

SYMBOLS

MECHANICAL

M-001

DM RAM

RAM RAM

216105.00

PIONEER HEALTH

CARE MANAGEMENT,

INC.

DSD

`[B-250`]

`[A-250`]

DUCT SMOKE DETECTOR

RETURN OR EXHAUST AIR GRILLE - TYPE "B", 250 CFM

SUPPLY AIR DIFFUSER - TYPE "A", 250 CFM

HORIZONTAL FIRE DAMPER

VERTICAL SMOKE DAMPER

VERTICAL FIRE DAMPER

V

G

ST

ST

SAN

SAN

DOMESTIC HOT WATER RETURN PIPING

DOMESTIC HOT WATER PIPING

DOMESTIC COLD WATER PIPING

VENT PIPING

NATURAL GAS PIPING

SANITARY PIPING BELOW FLOOR OR GRADE

SANITARY PIPING ABOVE FLOOR

STORM PIPING BELOW FLOOR OR GRADE

STORM PIPING ABOVE FLOOR

FP FIRE PROTECTION PIPING

GRISWOLD AUTOMATIC FLOW LIMITING VALVE

THREE WAY CONTROL VALVE (PNEUMATIC)

TWO WAY CONTROL VALVE (PNEUMATIC)

FLEXIBLE CONNECTION

FLOW ARROW

ISOLATION GATE VALVE

CHECK VALVE

UNION

CAP

REDUCER

EXTERIOR WALL HYDRANT

VALVE IN RISER

PRESSURE REGULATING VALVE

TEMPERATURE & PRESSURE RELIEF VALVE

INLINE PUMP

FS

FLOW SWITCH

PRESSURE GAUGE W/COCK

MANUAL AIR VENT

AUTOMATIC AIR VENT

PIPE ANCHOR

PIPE GUIDE

WATER PIPING LOCATED OUTSIDE OF BUILDING

W

HORIZONTAL SMOKE DAMPER

SLOT DIFFUSER

S

S

HORIZONTAL COMBINATION FIRE/SMOKE DAMPER

VERTICAL COMBINATION FIRE/SMOKE DAMPER

MOTORIZED DAMPER

MANUAL DAMPER

RFREFRIGERANT LINE

PRESSURE SENSOR OR SWITCH

PS

THERMOMETER

PRESSURE REGULATING OR REDUCING VALVE

T

SERVICE SINK

FLUSH TANK WATER CLOSET

FLUSH VALVE FLOOR MOUNTED

FLUSH VALVE WALL MOUNTED

URINAL

LAVATORY OR SINK

FLOOR SINK

THERMOSTAT OR WALL SENSOR

FLOOR DRAIN

ROOF DRAIN BELOW ROOF (FLOOR PLAN)

ROOF DRAIN ON ROOF (ROOF PLAN)

EXHAUST FAN WITH FAN ABOVE (FLOOR PLAN)

EXHAUST FAN ON ROOF (ROOF PLAN)

CO UP TO GRADE

CO ABOVE FLOOR

CO UP TO FLOOR

SAN

SAN

SAN

ELBOW DROPPING DOWN

ELBOW RISING UP

TEE WITH PIPE DOWN

TEE WITH PIPE UP

SECONDARY EMERGENCY DRAINAGE PIPINGSED

140° HOT WATER FOR KITCHEN

THREE WAY CONTROL VALVE (ELECTRIC)

TWO WAY CONTROL VALVE (ELECTRIC)

KITCHEN MASTER GAS VALVE

GAS REGULATOR

EX. VERTICAL FIRE DAMPER

EX. HORIZONTAL FIRE DAMPER

CO2

CARBON DIOXIDE SENSOR

MISC. EQUIP. COND DRAIN PIPINGCD

INTERIOR HOSE BIB

DUCT PRESSURE SENSOR

PRV

REDUCED PRESURE BACKFLOW PREVENTERRPBP

ACID VENT PIPINGAV

140°

RAIN CONDUCTORRC

\\m

aib

c1

9\d

ra

win

gs\1

6-N

SA

\2

01

9-1

62

0 O

akrid

ge

M

an

or N

ursin

g H

om

e M

ech

an

ica

l a

nd

S

tru

ctu

ra

l R

evie

w\D

OW

NL

OA

DE

D C

AD

F

ile

s\M

ech

an

ica

l\M

-0

01

.d

wg

, M

od

el, 7

/1

5/2

02

0 9

:1

1:5

7 A

M, sm

ag

uire

, 1

2:1

2

7/15/2020MAI # 2019-1620

Page 2: GENERAL ABBREVIATIONS DUCTWORK...double line duct ring 90° tap take-off duct mtd. sidewall reg./grille return/exhaust converge bullhead 8 feet maximum flexible duct open end duct

Sheet Title:

Sheet Number:

Date: Issued for:

05-19-20 OWNER REVIEW

OAKRIDGE MANOR

NURSING AND

REHABILITATION

NSA Architects, Engineers, Planners

Copyright C 2020

Project Number:

Project Title:

Client:

DRAWN DESIGNED

CHECKED APPROVED

06-26-20 ISSUED FOR PERMITS

CONSULTING ENGINEERSMacMILLAN ASSOCIATES

BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET

www.macmillanassociates.com(989) 894-4300 F(989) 894-9930

06-05-20 95% REVIEW

FLOOR PLAN

HVAC COMPOSITE

M-100

DM RAM

RAM RAM

216105.00

PIONEER HEALTH

CARE MANAGEMENT,

INC.

HVAC COMPOSITE FLOOR PLAN

1/16"=1'-0"

\\m

aib

c1

9\d

ra

win

gs\1

6-N

SA

\2

01

9-1

62

0 O

akrid

ge

M

an

or N

ursin

g H

om

e M

ech

an

ica

l a

nd

S

tru

ctu

ra

l R

evie

w\D

OW

NL

OA

DE

D C

AD

F

ile

s\M

ech

an

ica

l\M

-0

1-H

VA

C.d

wg

, M

od

el, 7

/1

5/2

02

0 9

:1

2:1

6 A

M, sm

ag

uire

, 0

.0

62

5:1

2

7/15/2020MAI # 2019-1620

Page 3: GENERAL ABBREVIATIONS DUCTWORK...double line duct ring 90° tap take-off duct mtd. sidewall reg./grille return/exhaust converge bullhead 8 feet maximum flexible duct open end duct

SE

E S

HE

ET

M

-1

02

FO

R C

ON

TIN

UA

TIO

N

SE

E S

HE

ET

M

-1

02

FO

R C

ON

TIN

UA

TIO

N

LOBBY

A102

VESTIBULE

A101

OPEN

OFFICE

A103

OFFICE

A104

COPY

ROOM

A105

MEN

A106

WOMEN

A107

IDF

A108

FUTURE

DIALYSIS

A109

STORAGE

A110

JANITOR

CLOSET

A112

ELECTRICAL

A111

BEVERAGE

A114

DINING

A115

CORRIDOR

A116

PT/OT

STORAGE

A118

TOILET

A117

CORRIDOR

A126

PT/OT

A119

MULTI-PURPOSE

A125

SALON

A124

CONFERENCE/

DINING

A123

SOCIAL

A121

OFFICE

A122

1

67

1213

14

15

16

17

18

19

25

26

27

31

32

33

34

35

38

35 35

3535

35

35

35

35

36

20

35

35

HVAC FLOOR PLAN A

1/8"=1'-0"

Sheet Title:

Sheet Number:

Date: Issued for:

05-19-20 OWNER REVIEW

OAKRIDGE MANOR

NURSING AND

REHABILITATION

NSA Architects, Engineers, Planners

Copyright C 2020

Project Number:

Project Title:

Client:

DRAWN DESIGNED

CHECKED APPROVED

06-26-20 ISSUED FOR PERMITS

CONSULTING ENGINEERSMacMILLAN ASSOCIATES

BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET

www.macmillanassociates.com(989) 894-4300 F(989) 894-9930

06-05-20 95% REVIEW

FLOOR PLAN WEST

HVAC PARTIAL

M-101

DM RAM

RAM RAM

216105.00

PIONEER HEALTH

CARE MANAGEMENT,

INC.

1

KEY NOTES:GENERAL NOTES:

28

2

3

4

5

6

7

8

9

10

11

12

13

14

KITCHEN

A113

15

16

17

18

19

20

21

22

23

24

25

26

27

ADMINISTRATION

A120

29

30

31

32

33

34

35

36

37

38

35

39

39

40

41

40 41

42

42

\\m

aib

c1

9\d

ra

win

gs\1

6-N

SA

\2

01

9-1

62

0 O

akrid

ge

M

an

or N

ursin

g H

om

e M

ech

an

ica

l a

nd

S

tru

ctu

ra

l R

evie

w\D

OW

NL

OA

DE

D C

AD

F

ile

s\P

la

ns\M

-H

P0

1-A

.d

wg

, M

od

el, 7

/1

5/2

02

0 9

:1

2:3

3 A

M, sm

ag

uire

, 0

.1

25

:1

2

7/15/2020MAI # 2019-1620

Page 4: GENERAL ABBREVIATIONS DUCTWORK...double line duct ring 90° tap take-off duct mtd. sidewall reg./grille return/exhaust converge bullhead 8 feet maximum flexible duct open end duct

A14

SE

E S

HE

ET

M

-1

01

FO

R C

ON

TIN

UA

TIO

N

SE

E S

HE

ET

M

-1

01

FO

R C

ON

TIN

UA

TIO

N

SEMI-PRIVATE

B149

SEMI-PRIVATE

B151

SEMI-PRIVATE

B153

SEMI-PRIVATE

B155

SEMI-PRIVATE

B157

TOILET

B147

SEMI-BARIATRIC

B158

SEMI-BARIATRIC

B159

SEMI-PRIVATE

B160

ELECT.

B145

SEMI-PRIVATE

B162

SEMI-PRIVATE

B164

SEMI-PRIVATE

B166

SEMI-PRIVATE

B168

PRIVATE

B169

PRIVATE

SUITE

B188

GUEST

ROOM

B193

CORRIDOR

B170

MECHANICAL

B187

STORAGE

B185

FACILITIES

B184

HOUSEKEEPING

B183

CLEAN

LINEN

B181

SOILED

LINEN

B180

LAUNDRY

B182

LOCKER

ROOM

B178

MEN

TOILET

B177

WOMENS

TOILET

B176

JANITOR

CLOSET

B175

CATV/TEL

B174

RECORDS

B172

STAFF

LUNCH

B173

CORRIDOR

B123

SEMI-PRIVATE

B122

SEMI-PRIVATE

B121

SEMI-PRIVATE

B120

SEMI-PRIVATE

B118

SEMI-PRIVATE

B116

SEMI-PRIVATE

B114

SEMI-PRIVATE

B112

IDF

B124LOUNGE

B125

SEMI-BARIATRIC

B111

SEMI-BARIATRIC

B110

SEMI-PRIVATE

B109

SEMI-PRIVATE

B107

SEMI-PRIVATE

B105

SEMI-PRIVATE

B103

SEMI-PRIVATE

B101

PRIVATE

B102

PRIVATE

B104

PRIVATE

B106

PRIVATE

B108

NURSE

B128

CORRIDOR

B127

TOILET

B126

CART/W-CHAIR

B133

TOILET

B134

CENTRAL

SHOWER

B135

ACTIVITY

B136

CAFE

B138

CORRIDOR

B137

SOILED

LINEN

B142

CLEAN

LINEN

B143

CLEAN

HOLDING

B144

MED

PREP

B141

NURSE

B140

NOURISHMENT

B139

PRIVATE

B156

PRIVATE

B154

PRIVATE

B152

PRIVATE

B150

CORRIDOR

B148

LOUNGE

B146

MDF

B186

PRIVATE

B161

PRIVATE

B163

PRIVATE

B165

PRIVATE

B167

SEMI-PRIVATE

B119

SEMI-PRIVATE

B117

SEMI-PRIVATE

B115

SEMI-PRIVATE

B113

DICTATION

B131

DICTATION

B132

MED

PREP

B129

OXYGEN

B130

34

8

35

35

2

5

22

28

10

11

23

3

34

35

35

35

36

37

34

34

HVAC FLOOR PLAN B

1/8"=1'-0"

Sheet Title:

Sheet Number:

Date: Issued for:

05-19-20 OWNER REVIEW

OAKRIDGE MANOR

NURSING AND

REHABILITATION

NSA Architects, Engineers, Planners

Copyright C 2020

Project Number:

Project Title:

Client:

DRAWN DESIGNED

CHECKED APPROVED

06-26-20 ISSUED FOR PERMITS

CONSULTING ENGINEERSMacMILLAN ASSOCIATES

BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET

www.macmillanassociates.com(989) 894-4300 F(989) 894-9930

06-05-20 95% REVIEW

FLOOR PLAN

HVAC PARTIAL

EAST

M-102

DM RAM

RAM RAM

216105.00

PIONEER HEALTH

CARE MANAGEMENT,

INC.

1

KEY NOTES:

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

4

21

24

9

33

29

38

38

35

37

35

35

20

39

39

39

35

\\m

aib

c1

9\d

ra

win

gs\1

6-N

SA

\2

01

9-1

62

0 O

akrid

ge

M

an

or N

ursin

g H

om

e M

ech

an

ica

l a

nd

S

tru

ctu

ra

l R

evie

w\D

OW

NL

OA

DE

D C

AD

F

ile

s\P

la

ns\M

-H

P0

1-B

.d

wg

, M

od

el, 7

/1

5/2

02

0 9

:1

2:5

4 A

M, sm

ag

uire

, 0

.1

25

:1

2

7/15/2020MAI # 2019-1620

Page 5: GENERAL ABBREVIATIONS DUCTWORK...double line duct ring 90° tap take-off duct mtd. sidewall reg./grille return/exhaust converge bullhead 8 feet maximum flexible duct open end duct

Sheet Title:

Sheet Number:

Date: Issued for:

05-19-20 OWNER REVIEW

OAKRIDGE MANOR

NURSING AND

REHABILITATION

NSA Architects, Engineers, Planners

Copyright C 2020

Project Number:

Project Title:

Client:

DRAWN DESIGNED

CHECKED APPROVED

06-26-20 ISSUED FOR PERMITS

CONSULTING ENGINEERSMacMILLAN ASSOCIATES

BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET

www.macmillanassociates.com(989) 894-4300 F(989) 894-9930

06-05-20 95% REVIEW

PLAN

MECHANICAL ROOF

M-121

DM RAM

RAM RAM

216105.00

PIONEER HEALTH

CARE MANAGEMENT,

INC.

ROOF PLAN - MECHANICAL

1/16"=1'-0"

\\m

aib

c1

9\d

ra

win

gs\1

6-N

SA

\2

01

9-1

62

0 O

akrid

ge

M

an

or N

ursin

g H

om

e M

ech

an

ica

l a

nd

S

tru

ctu

ra

l R

evie

w\D

OW

NL

OA

DE

D C

AD

F

ile

s\ro

of\M

-1

21

.d

wg

, M

od

el, 7

/1

5/2

02

0 9

:1

3:0

4 A

M, sm

ag

uire

, 0

.0

62

5:1

2

7/15/2020MAI # 2019-1620

Page 6: GENERAL ABBREVIATIONS DUCTWORK...double line duct ring 90° tap take-off duct mtd. sidewall reg./grille return/exhaust converge bullhead 8 feet maximum flexible duct open end duct

SCALE: NONE

BELT DRIVE CENTRIFUGAL

UPBLAST ROOF EXHAUSTER

SCALE: NONE

INTAKE AND EXHAUST HOOD

SCALE: NONE

TYPICAL AIR TERMINAL DEVICE

WITH REHEAT COIL

SCALE: NONE

TYPICAL CEILING RETURN AIR

GRILLE SOUND TRAP

SCALE: NONE

SUPPLY AIR RECTANGULAR

DUCT CONNECTION

SCALE: NONE

KITCHEN HOOD EXHAUST FAN

SCALE: NONE

VERTICAL FIRE DAMPER

SCALE: NONE

HORIZONTAL FIRE DAMPER

SCALE: NONE

FIRE AND SMOKE DAMPER

Sheet Title:

Sheet Number:

Date: Issued for:

05-19-20 OWNER REVIEW

OAKRIDGE MANOR

NURSING AND

REHABILITATION

NSA Architects, Engineers, Planners

Copyright C 2020

Project Number:

Project Title:

Client:

DRAWN DESIGNED

CHECKED APPROVED

06-26-20 ISSUED FOR PERMITS

CONSULTING ENGINEERSMacMILLAN ASSOCIATES

BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET

www.macmillanassociates.com(989) 894-4300 F(989) 894-9930

06-05-20 95% REVIEW

DETAILS

MECHANICAL

M-501

DM RAM

RAM RAM

216105.00

PIONEER HEALTH

CARE MANAGEMENT,

INC.

\\m

aib

c1

9\d

ra

win

gs\1

6-N

SA

\2

01

9-1

62

0 O

akrid

ge

M

an

or N

ursin

g H

om

e M

ech

an

ica

l a

nd

S

tru

ctu

ra

l R

evie

w\D

OW

NL

OA

DE

D C

AD

F

ile

s\S

ch

ed

ule

s\M

-D

T.d

wg

, M

od

el, 7

/1

5/2

02

0 9

:1

3:1

2 A

M, sm

ag

uire

, 0

.1

25

:1

2

7/15/2020MAI # 2019-1620

Page 7: GENERAL ABBREVIATIONS DUCTWORK...double line duct ring 90° tap take-off duct mtd. sidewall reg./grille return/exhaust converge bullhead 8 feet maximum flexible duct open end duct

NOTES:

NOTES:

TYPICAL RTU SEQUENCE OF OPERATION:

··

···

··

·

··

·

··

·

··

·

·

··

·

··

·

···

·

··

·

·

·

·

·

·

·

SCALE: NONE

1

M-502

EXHAUST FAN MOTOR

STARTER I/O DIAGRAM

SCALE: NONE

2

M-502

EXHAUST FAN CONTROL DIAGRAM

SCALE: NONE

3

M-502

TYPICAL TERMINAL BOX W/ELECTRIC

REHEAT COIL CONTROL DIAGRAM

SCALE: NONE

4

M-502

TYPICAL RTU VFD CONTROL

DIAGRAM

SCALE: NONE

5

M-502

TYPICAL RTU CONTROL

DIAGRAM

SCALE: NONE

6

M-502

MUA-1 AND MUA-2 UNIT

CONTROL DIAGRAM

TYPICAL MUA UNIT SEQUENCE OF OPERATION:

··

···

··

·

··

·

··

·

··

·

·

··

·

··

·

·

·

Sheet Title:

Sheet Number:

Date: Issued for:

05-19-20 OWNER REVIEW

OAKRIDGE MANOR

NURSING AND

REHABILITATION

NSA Architects, Engineers, Planners

Copyright C 2020

Project Number:

Project Title:

Client:

DRAWN DESIGNED

CHECKED APPROVED

06-26-20 ISSUED FOR PERMITS

CONSULTING ENGINEERSMacMILLAN ASSOCIATES

BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET

www.macmillanassociates.com(989) 894-4300 F(989) 894-9930

06-05-20 95% REVIEW

CONTROLS

MECHANICAL

M-502

DM RAM

RAM RAM

216105.00

PIONEER HEALTH

CARE MANAGEMENT,

INC.

\\m

aib

c1

9\d

ra

win

gs\1

6-N

SA

\2

01

9-1

62

0 O

akrid

ge

M

an

or N

ursin

g H

om

e M

ech

an

ica

l a

nd

S

tru

ctu

ra

l R

evie

w\D

OW

NL

OA

DE

D C

AD

F

ile

s\M

ech

an

ica

l\M

-5

02

.d

wg

, M

od

el, 7

/1

5/2

02

0 9

:1

3:1

7 A

M, sm

ag

uire

, 0

.1

25

:1

2

7/15/2020MAI # 2019-1620

Page 8: GENERAL ABBREVIATIONS DUCTWORK...double line duct ring 90° tap take-off duct mtd. sidewall reg./grille return/exhaust converge bullhead 8 feet maximum flexible duct open end duct

Sheet Title:

Sheet Number:

Date: Issued for:

05-19-20 OWNER REVIEW

OAKRIDGE MANOR

NURSING AND

REHABILITATION

NSA Architects, Engineers, Planners

Copyright C 2020

Project Number:

Project Title:

Client:

DRAWN DESIGNED

CHECKED APPROVED

06-26-20 ISSUED FOR PERMITS

CONSULTING ENGINEERSMacMILLAN ASSOCIATES

BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET

www.macmillanassociates.com(989) 894-4300 F(989) 894-9930

06-05-20 95% REVIEW

SCHEDULES

MECHANICAL

M-601

DM RAM

RAM RAM

216105.00

PIONEER HEALTH

CARE MANAGEMENT,

INC.

EXHAUST FAN SCHEDULE

TAG BASIS OF DESIGN LOCATION SERVICE TYPE CFM E.S.P. DRIVE

MOTOR DATA

COMMENTSHP VOLTS PHASE Hz

EF-1GREENHECK SQ-65-D

ROOM JC RM A112 IN-LNE 100 0.25 DIRECT

1/30

115 1 60

1,2,6

EF-2GREENHECK SQ-80-G

ROOM ELECTRICAL RM A111 IN-LNE 200 0.25 DIRECT

1/20

115 1 60

1,2,5

EF-3A GREENHECK CUBE-141-5 ROOF KITCHEN HOOD CENTR. UPBLAST 1500 1 BELT 1/2 208 3 60

1,2,3,8

EF-3B GREENHECK CUBE-161-5 ROOF KITCHEN HOOD CENTR. UPBLAST 1900 1 BELT 1/2 208 3 60

1,2,3,8

EF-4 GREENHECK GB-101-4 ROOF KITCHEN DISHWASHER CENTR. 600 0.75 BELT 1/4 115 1 60

1,2,3

EF-5 GREENHECK G-080 ROOF

TOILET RM A106, A107

CENTR. 150 0.25 BELT

1/20

115 1 60

1,2,3,6

EF-6 GREENHECK GB-081 ROOF SALON A124 CENTR. 400 0.25 BELT

1/6

115 1 60

1,2,3,6

EF-7 GREENHECK G-080 ROOF TOILET RM A117 CENTR. 200 0.25 DIRECT

1/30

115 1 60

1,2,3,7

EF-8 GREENHECK GB-220HP-20 ROOF

PRIVATE RM'S (NORTH)

CENTR. 3505 2 BELT 3.0 208 3 60

1,2,3,9

EF-9 GREENHECK USF-306-BI-X ROOF OXYGEN B130 CENTR. UTILITY 125 0.25 DIRECT

1/15

115 1 60

1,2,3,4,6

EF-10 GREENHECK GB-220-HP-20 ROOF

PRIVATE RM'S (SOUTH)

CENTR. 3075 2 BELT 2.0 208 3 60

1,2,3,10

EF-11 GREENHECK GB-131-3 ROOF COMMON AREAS CENTR. 1175 0.5 BELT 1/4 115 1 60

1,2,3,6

EF-12 GREENHECK SQ-80-G ROOM MECHANICAL RM B187 IN-LNE 200 0.25 DIRECT 1/20 115 1 60 1,2,5

NOTES:

1) PROVIDE DISCONNECT SWITCH.

2) PROVIDE BACK-DRAFT DAMPER, AND BIRDSCREEN WHERE APPLICABLE.

3) PROVIDE ROOF CURB.

4) IN-LINE SPARK RESISTANT, ALUMINUM CONSTRUCTION.

5) PROVIDE THERMOSTAT. ( FAN ENERGIZED AT ROOM TEMPERATURE GREATER THAN 95 DEGREE). PROVIDE SUPPORT WITH VIBRATION ISOLATORS.

6) PROVIDE WITH TIMER

7) INTERLOCK WITH LIGHT SWITCH

8) INTERLOCK WITH HOOD's HEAT SWITCH AND MAU-3

9) INTERLOCK WITH MAU-1

10) INTERLOCK WITH MAU-2

Variable Air Volume Single Duct Terminal Units

Schedule

Unit Tags

RTU

Quantity

Airflow

Electric Heating

Notes

Unit model

Primary inlet

Design

cooling

airflow

Min cooling

airflow

Valve

heating

airflow

Coil heating

capacity

Electric

heater

kilowatt

Electric

heater

voltage

Electric heater

stage

EDB (deg F) LAT (deg F)

cfm cfm cfm MBh

VAV-1 RTU-1 1 VCEF

10" (254mm)

1375 415 685 27.32 8 208/3 1 55 92 1 thru 7

VAV-2 RTU-1 1 VCEF

6" (152mm)

500 150 250 10.24 3 208/3 1 55 93 1 thru 7

VAV-3 RTU-1 1 VCEF

5" (127mm)

255 100 125 5.12 1.5 208/1 1 55 93 1 thru 7

VAV-4 RTU-1 1 VCEF

14" (356mm)

2400 720 1200 47.81 14 208/3 1 55 92 1 thru 7

VAV-5 RTU-1 1 VCEF

12" (305mm)

1630 500 825 34.15 10 208/3 1 55 93 1 thru 7

VAV-6 RTU-1 1 VCEF

14" (356mm)

2610 785 1305 51.22 15 208/3 1 55 91 1 thru 7

VAV-7 RTU-4 1 VCEF

6" (152mm)

365 110 185 6.83 2 208/1 1 55 89 1 thru 7

VAV-8 RTU-4 1 VCEF

12" (305mm)

1780 525 900 37.56 11 208/3 1 55 93 1 thru 7

VAV-9 RTU-4 1 VCEF

8" (203mm)

625 190 315 13.66 4 208/3 1 55 95 1 thru 7

VAV-10 RTU-4 1 VCEF

5" (127mm)

300 90 150 5.12 1.5 208/1 1 55 86 1 thru 7

VAV-11 RTU-4 1 VCEF

5" (127mm)

325 100 175 6.83 2 208/1 1 55 91 1 thru 7

VAV-12 RTU-4 1 VCEF

8" (203mm)

660 200 330 13.66 4 208/3 1 55 93 1 thru 7

VAV-13 RTU-2 1 VCEF

8" (203mm)

900 270 450 18.78 5.5 208/3 1 55 93 1 thru 7

VAV-14 RTU-2 1 VCEF

10" (254mm)

1015 305 500 20.49 6 208/3 1 55 93 1 thru 7

VAV-15 RTU-2 1 VCEF

12" (305mm)

1420 425 710 27.32 8 208/3 1 55 90 1 thru 7

VAV-16 RTU-2 1 VCEF

10" (254mm)

1110 333 555 22.2 6.5 208/3 1 55 92 1 thru 7

VAV-17 RTU-2 1 VCEF

6" (152mm)

400 120 200 8.54 2.5 208/1 1 55 94 1 thru 7

VAV-18 RTU-3 1 VCEF

10" (254mm)

950 285 475 18.78 5.5 208/3 1 55 91 1 thru 7

VAV-19 RTU-3 1 VCEF

8" (203mm)

600 180 300 11.95 3.5 208/3 1 55 92 1 thru 7

VAV-20 RTU-3 1 VCEF

6" (152mm)

450 135 225 10.24 3 208/3 1 55 97 1 thru 7

VAV-21 RTU-3 1 VCEF

10" (254mm)

930 280 465 18.78 5.5 208/3 1 55 92 1 thru 7

VAV-22 RTU-3 1 VCEF

10" (254mm)

1000 300 500 20.49 6 208/3 1 55 93 1 thru 7

NOTES:

1

Units to be Trane (or equal by Titus) model, size, and configuration as indicated in schedule and on drawings

2

Provide with zone temperature sensor

3

Provide with factory-wired discharge air temperature sensor

4

Provide factory-mounted and pre-programmed, pressure-independent, BACnet DDC controller with airflow measurement

5 Provide unit-mounted disconnect

6 Provide with SCR Electric Heat Control

7

Provide with Factory Control Power Transformer

LOUVER SCHEDULE

TAG

BASIS OF DESIGN

SERVING CFM INTAKE / RELIEF

DIMENSIONS (INCHES)

NOTESMANUFACTURER MODEL WIDTH HEIGHT DEPTH

L-1 GREENHECK GCI-202 MECH/ELECTRICAL ROOM 200 INTAKE 14 12 6

1,2,3,4

L-2 GREENHECK GCE-202 MECH/ELECTRICAL ROOM 200 EXHAUST 14 12 6

1,2,5

NOTES:

1) LOUVER COLOR TO MATCH ARCHITECTURAL EXTERIOR.

2) INSTALL LOUVERS PER MANUFACTURER'S RECOMMENDATION. PROVIDE BIRD AND INSECT SCREEN, AND EXTENDED SILL.

3) PROVIDE MOTORIZED DAMPER INTERLOCKED WITH EF.

4) LOCATE AT 18" A.F.F.

5) LOCATE AT 18" BELOW CEILING

HVAC Unit Schedule

TAG BASIS OF DESIGN AREA SERVED

HEATING CAPACITY COOLING CAPACITY SUPPLY FAN

FILTERS RATING

MERV ELECTRICAL

MIN OA

CFM

WEIGH

T

(LBS)(±

5%)

NOTES/ACCESSORIESTYPE

INPUT

MBH

OUTPUT

MBH

TOTAL

MBH

SENS

MBH

EER

(NOTE-5)

DRIVE CFM ESP HP PRE FINAL

VOLTS/P

HASE FLA AMPS MCA AMPS MOP AMPS

RTU-1 AAON RN-025-8-0-EA09-3CB COMMON AREAS

GAS

MODULATING

540 432 306.74 233.55 11.3 DIRECT 8770 2.5 15 MERV 8 MERV14 208/3/60 163 175 200 2440 28861,2,3,4,5,6,7,8,9

RTU-2 AAON RN-013-8-0-EB09-3GB COMMON AREAS

GAS

MODULATING

292.5 234 160.37 128.78 12.1 DIRECT 4845 2.5 5 MERV 8 MERV14 208/3/60 74 79 100 1078 19711,2,3,4,5,6,7,8,9

RTU-3 AAON RN-011-8-0-EB09-3FB COMMON AREAS

GAS

MODULATING

195 156 131.54 105.22 12.7 DIRECT 3930 2.5 5 MERV 8 MERV14 208/3/60 55 59 70 766 18101,2,3,4,5,6,7,8,9

RTU-4 AAON RN-015-8-0-EA09-3GB COMMON AREAS

GAS

MODULATING

292.5 234 184.14 127.61 11.1 DIRECT 4055 2.5 5 MERV 8 MERV14 208/3/60 80 86 110 1735 19271,2,3,4,5,6,7,8,9

MAU-1 AAON RN-015-8-0-EA09-36B RESIDENT UNITS

GAS

MODULATING

390 315.9 202.86 84.85 11.1 DIRECT 2950 2 3 MERV 8 MERV14 208/3/60 74 80 100 2950 19291,4,5,6,7,8,9,10,12

MAU-2 AAON RN-015-8-0-EA09-36B RESIDENT UNITS

GAS

MODULATING

390 315.9 202.86 84.85 11.1 DIRECT 2950 2 3 MERV 8 MERV14 208/3/60 74 80 100 2950 19291,4,5,6,7,8,9,11,12

MAU-3 AAON RN-015-8-0-EA09-36B KITCHEN

GAS

MODULATING

390 315.9 209.39 87.68 11.1 DIRECT 3300 1.5 3 --- MERV 13 208/3/60 74 80 100 3300 192913,14,15

NOTE 2: EXTERNAL STATIC PRESSURE CALCULATED FOR: FILTERS, SUPPLY AND RETURN DUCTWORK.

NOTE 3: UNIT TO BE BOTTOM SUPPLY/ RETURN

NOTE 4: PROVIDE SMOKE DETECTORS FOR S.A./R.A. DUCTWORK

NOTE 5: EER RATINGS SHOWN FOR UNITS AT ARI CONDITIONS

NOTE 6: PROVIDE WITH ECONOMIZER, THERMOSTAT, DISCONNECT SWITCH, MODULATING HOT GAS REHEAT, CO2 SENSORS.

NOTE 7: PROVIDE INSIDE DUCT THERMOSTAT, DISCONNECT SWITCH ON EACH POWER SOURCE, MODULATING HOT GAS REHEAT.

NOTE 8: MANUFACTURER'S INSTALLATION INSTRUCTIONS MUST BE AVAILABLE AT THE JOB SITE BEFORE, DURING, AND AFTER UNITS INSTALLATION.

NOTE 9: PROVIDE FILTER IN ROOF CURB.

NOTE 10: INTERLOCK MAU-1 WITH EF-8.

NOTE 11: INTERLOCK MAU-2 WITH EF-10.

NOTE 12: PROVIDE MAU-1 AND MAU-2 WITH STAINLESS STEEL HEAT EXCHANGER.

NOTE 13: INTERLOCK MAU-3 WITH EF-3A AND EF-3B.

NOTE 14: PROVIDE AND INSTALL RTU/MAU CONTROL PANEL. COORDINATE WITH OWNER FOR FINAL LOCATION.

NOTE 15: PROVIDE DISCONNECT SWITCH FOR MAU-3.

ELECTRIC UNIT HEATER SCHEDULE

TAG

BASIS OF

DESIGN

LOCATION HEATING CAPACITY

ELECTRICAL

COMMENTS

VOLTS/PHASE

EUH-1

Q-MARK

MUH0381 MECH/ELECTRICAL RM 3000 WATTS 208/1 1

NOTE 1: UNIT MOUNTED VERTICALLY, HEAVY GAUGE STEEL HOUSING, PULL THROUGH AIR FLOW, ENCLOSED FAN

MOTOR, ALUMINUM-FINNED, COPPER CLAD STEEL SHEATH HEATING ELEMENT, ADJUSTABLE LOUVER, UL, NEC,

AND OSHA, PROVIDED FACTORY UNIVERSAL MOUNTING BRACKET, INTEGRAL ADJUSTABLE THERMOSTAT,

DISCONNECT SWITCH.

ELECTRIC RADIANT CEILING PANEL SCHEDULE

TAG

BASIS OF

DESIGN LOCATION HEATING CAPACITY

ELECTRICAL

COMMENTSVOLTS/PHASE

ERCP-1MARKELRCP127

EXTERIOR RESTROOMS 750 120/1 1,2,3

NOTE 1: PROVIDE WITH ET9 SERIES MODEL AET9DWTS LINE VOLTAGE THERMOSTAT, DOUBLE POLEWITH POSITIVE OFF AND SINGLE KNOB WITH 50 TO 90 DEGREE F RANGE.NOTE 2: 2'x4' PANEL FOR DRYWALL CEILING WITH SILICONE SEALED METAL PARTS FOR HIGHHUMIDITY APPLICATIONS.NOTE 3: ERCP SHALL BE FURNISHED BY MECHANICAL CONTRACTOR AND INSTALLED AND WIRED BYELECTRICAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE INSTALLATION OFTHE NEW RADIANT CEILING PANEL WITH THE ELECTRICAL CONTRACTOR.

(PTAC) Packaged Terminal Air Conditioning Unit Schedule

TYPE

MANUFACTURER

MODEL AREA SERVED

HEATING CAPACITY COOLING CAPACITY

SUPPLY

FAN ELECTRICAL

MIN OA

CFM

DIMENSIONS

WxHxD NOTESCORD KW BTUH NOMINAL MBH CFM VOLTS/PHASE MCA AMPS MOP AMPS

PTAC-1 LG/ LP123HDUC RESIDENT RM 20 AMP 3.2

10,900 11,900

420 208/1 19.8 20 70 42x16x21

1,2,3

PTAC-2 LG/ LP093HDUC RESIDENT RM 20 AMP 3.2

10,900 10,000

270 208/1 19.8 20 60 42x16x21

1,2,3

PTAC-3 LG/ LP153HDUC RESIDENT RM 30 AMP 4.7

15,700 14,900

420 208/1 28.3 30 70 42x16x21

1,2,3

NOTE 1: UNIT SELECTIONS ARE BASED ON 95°F DB AND 75°F WB OUTSIDE AIR CONDITIONS.

NOTE 2: PROVIDE WALL SLEEVE, ARCHITECTURAL OUTDOOR AIR GRILLE, DISCONNECT SWITCH, WALL THERMOSTAT, FACTORY CORD AND PLUG.

NOTE 3: PROVIDE MANUFACTURER'S STANDARD CLEANABLE OR REPLACEABLE FILTER.

ELECTRIC CABINET HEATER SCHEDULE

TAG

BASIS OF

DESIGN LOCATION HEATING CAPACITY

ELECTRICAL

COMMENTSVOLTS/PHASE

ECH-1MARKEL

E3383D-RP ENTRANCE DOOR 1500 WATTS 120/1 1,2

NOTE 1: INTEGRAL ADJUSTABLE THERMOSTAT, DISCONNECT SWITCH

NOTE 2: CEILING RECESSED

GRILLE, REGISTER AND DIFFUSER SCHEDULE

TAG BASIS OF DESIGN TYPE CFM RANGE

NECK SIZE (IN.) LAY-IN MODULE (IN.) SURFACE MODULE (IN.)

MAX NC NOTES

S-1 TITUS, 272RS SUPPLY 50-150 10x6 -- 12x8 30 1,2

S-2 TITUS, TMS SUPPLY 50-150 6 12x12 -- 30 1,2

S-3 TITUS, TMS SUPPLY 50-150 6 24x24 -- 30 1,2

S-3A TITUS, TMS-AA SUPPLY 50-150 6 24x24 -- 30 5

S-4 TITUS, TMS SUPPLY 150-300 8 24x24 -- 30 1,2

S-4A TITUS, TMS-AA SUPPLY 150-300 8 24x24 -- 30 1,2

S-5 TITUS, TMS SUPPLY 300-500 10 24x24 -- 30 1,2

S-6 TITUS, TDC-FR SUPPLY 50-150 6 12x12 -- 30 1,2,5

S-7 TITUS 272RS SUPPLY 50-150 6 -- 8x8 30 1,2

S-8 TITUS 272RS SUPPLY 300-500 10 -- 12x8 30 1,2

S-9 TITUS TBD-10 SUPPLY 100-250 8 -- -- 30 2,4

R-1 TITUS. 350RL RETURN 0-500 SEE DWG -- 12x8 30 1,2

R-2 TITUS, PAR RETURN 0-1800 SEE DWG -- 24x24 30 1,2

R-3 TITUS. 350RL RETURN 0-1000 SEE DWG -- 18x12 30 1,2

E-1 TITUS, 50F EXHAUST 0-150 6 -- 12x12 30 1,2

E-2 TITUS, 50F EXHAUST 0-150 8 -- 12x12 30 1,2

E-3 TITUS, 50F EXHAUST 0-500 10 -- 12x12 30 1,2

E-4 TITUS, PAS-FR EXHAUST 0-150 6 12x12 -- 30 1,2,5

NOTE 1: OPPOSED BLADE VOLUME DAMPER

NOTE 2: WHITE FINISH

NOTE 3: BLANK OFF 1 SIDE (FACING WALL)

NOTE 4: PLENUM SLOT DIFFUSER, 48" LONG, STEEL, 1 SLOT @ 1" WIDTH

NOTE 5: FIRE RATED

DOOR HEATER SCHEDULE

TAG BASIS OF DESIGN LOCATION HEATING CAPACITY

ELECTRICAL

COMMENTSVOLTS/PHASE

DH-1 BERNER ARC16-2084EX-160 VESTIBULE 16kW 208/3 1,2

NOTE 1: CEILING RECESSED DOOR HEATER.NOTE 2: PROVIDE WITH CONTROLS TO HOLD SPACE TEMP DURING INACTIVITY AND DOOR CONTACTS TO ACTIVATEHEATER WHEN DOOR OPENS.

SINGLE HVAC SPLIT SYSTEM SCHEDULE

TAG

COOLING

TONS

TOTAL

COOLING

(BTUH)

SEER REFRIGERANT

TOTAL

HEATING

INDOOR UNIT OUTDOOR UNIT ELECTRICAL BASIS OF DESIGN

NOTES

INDOOR OUTDR CFM HI/MED/LOW LOCATION FILTER LOCATION FAN VOLTS/ø/HZ FLA

INDOOR

MODEL

OUTDOOR

MODEL

AC-1AC-2AC-3AC-4

CU-1CU-2CU-3CU-4

2 25,200 17 134a - 559/475/390A108, B139,

B174,B124,B186 WASHABLE ROOF PROP. 208/1ø/60 16.9 PANASONICS-26PK1U6

PANASONICU-26PS1U6

1,2,3,4,5,6

NOTES:

1) LOW AMBIENT CONTROL, MICROPROCESSOR CONTROLS.

2) PROVIDE THERMOSTAT, (WEATHER DUTY) DISCONNECT SWITCH, REMOTE CONTROLLER.

3) PROVIDE INDOOR WALL SUPPORT, INSTALL PER MANUFACTURER RECOMMENDATION.

4) PROVIDE OUTDOOR, SUPPORT SIMILAR TO THYBAR MODEL TEMS-3 12" HIGH.

5) PROVIDE PROPERLY SIZED REFRIGERANT LINE SET. INSTALL PER MANUFACTURER RECOMMENDATION.

6) PROVIDE CONDENSATE PUMP

\\m

aib

c1

9\d

ra

win

gs\1

6-N

SA

\2

01

9-1

62

0 O

akrid

ge

M

an

or N

ursin

g H

om

e M

ech

an

ica

l a

nd

S

tru

ctu

ra

l R

evie

w\D

OW

NL

OA

DE

D C

AD

F

ile

s\S

ch

ed

ule

s\M

-S

H.d

wg

, M

od

el, 7

/1

5/2

02

0 9

:1

3:2

7 A

M, sm

ag

uire

, 1

2:1

2

7/15/2020MAI # 2019-1620