general abbreviations ductwork...double line duct ring 90° tap take-off duct mtd. sidewall...
TRANSCRIPT
LINEAR FEET
KILOWATT
MEZZANINE
MECHANICAL
MOTOR CONTROL CENTER
LEAVING WATER TEMPERATURE
LINEAR DIFFUSER
LEAVING AIR TEMPERATURE
NUMBER
MOUNTED
MINIMUM
OUTSIDE AIR
POUNDS PER CUBIC FOOT
OUTSIDE AIR INTAKE
PRESSURE DROP
OUTSIDE DIAMETER
NOT TO SCALE
NOT IN CONTRACT
NOT APPLICABLE
OUTSIDE AIR UNIT
MANUFACTURER
REQUIRED
RETURN FAN
REVOLUTIONS PER MINUTE
POUNDS PER SQUARE INCH GAUGE
RETURN REGISTER
REQUIREMENTS
RELATIVE HUMIDITY
RETURN GRILLE
SUPPLY FAN
SQUARE
SCREEN
SUPPLY
SQUARE FEET
TEMPERATURE
TRANSFER FAN
STAINLESS STEEL
SUPPLY REGISTER
SLIDE GATE DAMPER
SPECIFICATIONS
SUPPLY GRILLE
SCHEDULE
TYPICAL
TRANSFER
WET BULB TEMPERATURE
WIRE MESH SCREEN
VOLUME DAMPER
UNDERCUT DOOR
TOP OF PIPE
TOP OF DUCT
TRANSFER GRILLE
PLUMBING
POUNDS PER SQUARE INCH DIFFERENTIAL
POUNDS PER SQUARE INCH ABSOLUTE
INCHES
LOUVER
IN
LF
LD
LAT
KW
LUVR
LWT
MEZZ
MECH
MCC
N/A
MTD
MIN
NO.
NTS
NIC
OD
OAI
OAU
PD
PCF
OA
MF'R
GENERAL ABBREVIATIONS
ADDITIONAL
AIR FILTER
ARCHITECT
BUILDING
BOTTOM OF DUCT
BRAKE HORSEPOWER
BOTTOM OF PIPE
ACCESS PANEL
ACOUSTICAL DUCT LINER
AIR CONDITIONING
ABOVE FINISHED FLOOR
ACCESS DOOR
CEILING
CENTERLINE
COLUMN
CONCRETE
CLEAN-OUT
CUBIC FEET
CUBIC FEET PER MINUTE
CEILING FAN
CEILING DIFFUSER
CONNECTION
CONTRACTOR
AC
ADD'L
ADL
AF
AD
ARCH
AP
AFF
BOP
BOD
BLDG
BHP
CFM
CF
CD
CLG
CLR
CL
COL
CONC
CO
CONTR
CUF
CONN
CLSCLOSED LOOP (HEAT PUMP) WATER SUPPLY
CLOSED LOOP (HEAT PUMP) WATER RETURN
RETURN
RELIEF
ROOM
STEEL
PSID
PSIA
PSIG
RET
REQ'S
REQ'D
RG
RH
RLF
RR
RM
RPM
RF
SF
SG
SCR
SQ
SGD
SPECS
SS
SR
STL
TF
TEMP
SUP
SQFT
SCH
VENT
TG
TOP
TOD
UC
TYP
TR
VD
WB
WMS
V
DIFFUSER
DIAMETER
EACH
DOWN
DIMENSION
EFFICIENCY
EMERGENCY
ELEVATION
ELECTRICAL
ENTERING AIR TEMPERATURE
EXHAUST REGISTER
EXHAUST FAN
EXHAUST GRILLE
DRY BULB TEMPERATURE
EXHAUST
FAN BOX
FREE AREA
EXPANSION
FIBERGLASS
FLEXIBLE
FEET
FURNISHED
GAUGE
ENTERING WATER TEMPERATURE
FEET PER MINUTE
EXTERNAL STATIC PRESSURE
DIFF
DIA
DB
EAT
EA
DN
DIM
EF
EG
EFF
ER
EMER
ELEV
ELEC
EXH
EWT
FA
FB
EXP
FLEX
FG
FT
FURN
GA
FPM
ESP
GALVANIZED
HEAD
HEIGHT
HOUR
HERTZ
GRADE (GROUND)
GENERAL CONTRACTOR
HORSEPOWER
HEAT PUMP UNIT
HEATING & VENTILATING UNIT
HEAT EXCHANGER
GC
GALV
GRD
HGT
HD
HP
HP
HR
HV
HZ
HX
PLBG
TEMPERATURE SENSOR OR THERMOSTAT
DOUBLE LINESINGLE LINE
RISE/DROP
TAP
45°
R
RISE/DROP
TAKE-OFF
EXHAUST
SUPPLY/RETURN/
RISE OR DROP
/EXHAUST
SUPPLY/RETURN
OFFSET
HORIZONTAL
DUCT DOWN
RETURN/EXHAUST
DUCT UP
RETURN/EXHAUST
SINGLE LINE
STANDARD RADIUS ELBOW
( R = W )
SUPPLY DUCT DOWN
SUPPLY DUCT UP
w
SUPPLY
W/ BRANCH DAMPERS
SPLIT TAKE-OFF
EXHAUST
SUPPLY / RETURN
OR
DUCTWORK
DOUBLE LINE
DUCT
RING
90°
TAP
TAKE-OFF
DUCT MTD.
SIDEWALL
REG./GRILLE
RETURN/EXHAUST
CONVERGE
BULLHEAD
8 FEET MAXIMUM
FLEXIBLE DUCT
OPEN END
DUCT W/
1/4"x1/4" WMS
RING DUCT
TAKEOFF TO
GOOD FOR
SUPPLY
BULLHEAD SPLIT
HARD
CEILING
TAKEOFF
TO
DIFF/GRILLE
DUCT MTD.
DIFF/GRILLE
OR
ELBOW
DUCT MTD.
DIFF/GRILLE
CEILING
LINED DUCT
ACOUSTICALLY
BACKDRAFT DAMPER
VERTICAL FIRE DAMPER
OUTSIDE AIR, RETURN, OR EXHAUST AIR FLOW
HORIZONTAL FIRE DAMPER
MANUAL VOLUME DAMPER
SUPPLY AIR FLOW
LOUVERED DOOR REFER TO ARCH. DWGS.
STANDARD 4-WAY BLOW SUPPLY DIFFUSER
STANDARD EXHAUST REGISTER
DUCT OR EQUIPMENT
TO BE REMOVED
BACK DRAFT DAMPERBDD
FSD FIRE SMOKE DAMPER W/ACCESS DOORS
SD SMOKE DAMPER
GRAVITY DAMPERGD
ELECTRIC CABINET HEATERECH
FIRE SMOKE DAMPER
CONSTANT AIR VOLUMECAV
VARIABLE AIR VOLUMEVAV
FSD
SMOKE DAMPER
SD
EXISTING(E)
OUTSIDE WALL FIRE SMOKE DAMPER
OFSD
STANDARD RETURN REGISTER
Sheet Title:
Sheet Number:
Date: Issued for:
05-19-20 OWNER REVIEW
OAKRIDGE MANOR
NURSING AND
REHABILITATION
NSA Architects, Engineers, Planners
Copyright C 2020
Project Number:
Project Title:
Client:
DRAWN DESIGNED
CHECKED APPROVED
06-26-20 ISSUED FOR PERMITS
CONSULTING ENGINEERSMacMILLAN ASSOCIATES
BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET
www.macmillanassociates.com(989) 894-4300 F(989) 894-9930
06-05-20 95% REVIEW
SYMBOLS
MECHANICAL
M-001
DM RAM
RAM RAM
216105.00
PIONEER HEALTH
CARE MANAGEMENT,
INC.
DSD
`[B-250`]
`[A-250`]
DUCT SMOKE DETECTOR
RETURN OR EXHAUST AIR GRILLE - TYPE "B", 250 CFM
SUPPLY AIR DIFFUSER - TYPE "A", 250 CFM
HORIZONTAL FIRE DAMPER
VERTICAL SMOKE DAMPER
VERTICAL FIRE DAMPER
V
G
ST
ST
SAN
SAN
DOMESTIC HOT WATER RETURN PIPING
DOMESTIC HOT WATER PIPING
DOMESTIC COLD WATER PIPING
VENT PIPING
NATURAL GAS PIPING
SANITARY PIPING BELOW FLOOR OR GRADE
SANITARY PIPING ABOVE FLOOR
STORM PIPING BELOW FLOOR OR GRADE
STORM PIPING ABOVE FLOOR
FP FIRE PROTECTION PIPING
GRISWOLD AUTOMATIC FLOW LIMITING VALVE
THREE WAY CONTROL VALVE (PNEUMATIC)
TWO WAY CONTROL VALVE (PNEUMATIC)
FLEXIBLE CONNECTION
FLOW ARROW
ISOLATION GATE VALVE
CHECK VALVE
UNION
CAP
REDUCER
EXTERIOR WALL HYDRANT
VALVE IN RISER
PRESSURE REGULATING VALVE
TEMPERATURE & PRESSURE RELIEF VALVE
INLINE PUMP
FS
FLOW SWITCH
PRESSURE GAUGE W/COCK
MANUAL AIR VENT
AUTOMATIC AIR VENT
PIPE ANCHOR
PIPE GUIDE
WATER PIPING LOCATED OUTSIDE OF BUILDING
W
HORIZONTAL SMOKE DAMPER
SLOT DIFFUSER
S
S
HORIZONTAL COMBINATION FIRE/SMOKE DAMPER
VERTICAL COMBINATION FIRE/SMOKE DAMPER
MOTORIZED DAMPER
MANUAL DAMPER
RFREFRIGERANT LINE
PRESSURE SENSOR OR SWITCH
PS
THERMOMETER
PRESSURE REGULATING OR REDUCING VALVE
T
SERVICE SINK
FLUSH TANK WATER CLOSET
FLUSH VALVE FLOOR MOUNTED
FLUSH VALVE WALL MOUNTED
URINAL
LAVATORY OR SINK
FLOOR SINK
THERMOSTAT OR WALL SENSOR
FLOOR DRAIN
ROOF DRAIN BELOW ROOF (FLOOR PLAN)
ROOF DRAIN ON ROOF (ROOF PLAN)
EXHAUST FAN WITH FAN ABOVE (FLOOR PLAN)
EXHAUST FAN ON ROOF (ROOF PLAN)
CO UP TO GRADE
CO ABOVE FLOOR
CO UP TO FLOOR
SAN
SAN
SAN
ELBOW DROPPING DOWN
ELBOW RISING UP
TEE WITH PIPE DOWN
TEE WITH PIPE UP
SECONDARY EMERGENCY DRAINAGE PIPINGSED
140° HOT WATER FOR KITCHEN
THREE WAY CONTROL VALVE (ELECTRIC)
TWO WAY CONTROL VALVE (ELECTRIC)
KITCHEN MASTER GAS VALVE
GAS REGULATOR
EX. VERTICAL FIRE DAMPER
EX. HORIZONTAL FIRE DAMPER
CO2
CARBON DIOXIDE SENSOR
MISC. EQUIP. COND DRAIN PIPINGCD
INTERIOR HOSE BIB
DUCT PRESSURE SENSOR
PRV
REDUCED PRESURE BACKFLOW PREVENTERRPBP
ACID VENT PIPINGAV
140°
RAIN CONDUCTORRC
\\m
aib
c1
9\d
ra
win
gs\1
6-N
SA
\2
01
9-1
62
0 O
akrid
ge
M
an
or N
ursin
g H
om
e M
ech
an
ica
l a
nd
S
tru
ctu
ra
l R
evie
w\D
OW
NL
OA
DE
D C
AD
F
ile
s\M
ech
an
ica
l\M
-0
01
.d
wg
, M
od
el, 7
/1
5/2
02
0 9
:1
1:5
7 A
M, sm
ag
uire
, 1
2:1
2
7/15/2020MAI # 2019-1620
Sheet Title:
Sheet Number:
Date: Issued for:
05-19-20 OWNER REVIEW
OAKRIDGE MANOR
NURSING AND
REHABILITATION
NSA Architects, Engineers, Planners
Copyright C 2020
Project Number:
Project Title:
Client:
DRAWN DESIGNED
CHECKED APPROVED
06-26-20 ISSUED FOR PERMITS
CONSULTING ENGINEERSMacMILLAN ASSOCIATES
BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET
www.macmillanassociates.com(989) 894-4300 F(989) 894-9930
06-05-20 95% REVIEW
FLOOR PLAN
HVAC COMPOSITE
M-100
DM RAM
RAM RAM
216105.00
PIONEER HEALTH
CARE MANAGEMENT,
INC.
HVAC COMPOSITE FLOOR PLAN
1/16"=1'-0"
\\m
aib
c1
9\d
ra
win
gs\1
6-N
SA
\2
01
9-1
62
0 O
akrid
ge
M
an
or N
ursin
g H
om
e M
ech
an
ica
l a
nd
S
tru
ctu
ra
l R
evie
w\D
OW
NL
OA
DE
D C
AD
F
ile
s\M
ech
an
ica
l\M
-0
1-H
VA
C.d
wg
, M
od
el, 7
/1
5/2
02
0 9
:1
2:1
6 A
M, sm
ag
uire
, 0
.0
62
5:1
2
7/15/2020MAI # 2019-1620
SE
E S
HE
ET
M
-1
02
FO
R C
ON
TIN
UA
TIO
N
SE
E S
HE
ET
M
-1
02
FO
R C
ON
TIN
UA
TIO
N
LOBBY
A102
VESTIBULE
A101
OPEN
OFFICE
A103
OFFICE
A104
COPY
ROOM
A105
MEN
A106
WOMEN
A107
IDF
A108
FUTURE
DIALYSIS
A109
STORAGE
A110
JANITOR
CLOSET
A112
ELECTRICAL
A111
BEVERAGE
A114
DINING
A115
CORRIDOR
A116
PT/OT
STORAGE
A118
TOILET
A117
CORRIDOR
A126
PT/OT
A119
MULTI-PURPOSE
A125
SALON
A124
CONFERENCE/
DINING
A123
SOCIAL
A121
OFFICE
A122
1
67
1213
14
15
16
17
18
19
25
26
27
31
32
33
34
35
38
35 35
3535
35
35
35
35
36
20
35
35
HVAC FLOOR PLAN A
1/8"=1'-0"
Sheet Title:
Sheet Number:
Date: Issued for:
05-19-20 OWNER REVIEW
OAKRIDGE MANOR
NURSING AND
REHABILITATION
NSA Architects, Engineers, Planners
Copyright C 2020
Project Number:
Project Title:
Client:
DRAWN DESIGNED
CHECKED APPROVED
06-26-20 ISSUED FOR PERMITS
CONSULTING ENGINEERSMacMILLAN ASSOCIATES
BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET
www.macmillanassociates.com(989) 894-4300 F(989) 894-9930
06-05-20 95% REVIEW
FLOOR PLAN WEST
HVAC PARTIAL
M-101
DM RAM
RAM RAM
216105.00
PIONEER HEALTH
CARE MANAGEMENT,
INC.
1
KEY NOTES:GENERAL NOTES:
28
2
3
4
5
6
7
8
9
10
11
12
13
14
KITCHEN
A113
15
16
17
18
19
20
21
22
23
24
25
26
27
ADMINISTRATION
A120
29
30
31
32
33
34
35
36
37
38
35
39
39
40
41
40 41
42
42
\\m
aib
c1
9\d
ra
win
gs\1
6-N
SA
\2
01
9-1
62
0 O
akrid
ge
M
an
or N
ursin
g H
om
e M
ech
an
ica
l a
nd
S
tru
ctu
ra
l R
evie
w\D
OW
NL
OA
DE
D C
AD
F
ile
s\P
la
ns\M
-H
P0
1-A
.d
wg
, M
od
el, 7
/1
5/2
02
0 9
:1
2:3
3 A
M, sm
ag
uire
, 0
.1
25
:1
2
7/15/2020MAI # 2019-1620
A14
SE
E S
HE
ET
M
-1
01
FO
R C
ON
TIN
UA
TIO
N
SE
E S
HE
ET
M
-1
01
FO
R C
ON
TIN
UA
TIO
N
SEMI-PRIVATE
B149
SEMI-PRIVATE
B151
SEMI-PRIVATE
B153
SEMI-PRIVATE
B155
SEMI-PRIVATE
B157
TOILET
B147
SEMI-BARIATRIC
B158
SEMI-BARIATRIC
B159
SEMI-PRIVATE
B160
ELECT.
B145
SEMI-PRIVATE
B162
SEMI-PRIVATE
B164
SEMI-PRIVATE
B166
SEMI-PRIVATE
B168
PRIVATE
B169
PRIVATE
SUITE
B188
GUEST
ROOM
B193
CORRIDOR
B170
MECHANICAL
B187
STORAGE
B185
FACILITIES
B184
HOUSEKEEPING
B183
CLEAN
LINEN
B181
SOILED
LINEN
B180
LAUNDRY
B182
LOCKER
ROOM
B178
MEN
TOILET
B177
WOMENS
TOILET
B176
JANITOR
CLOSET
B175
CATV/TEL
B174
RECORDS
B172
STAFF
LUNCH
B173
CORRIDOR
B123
SEMI-PRIVATE
B122
SEMI-PRIVATE
B121
SEMI-PRIVATE
B120
SEMI-PRIVATE
B118
SEMI-PRIVATE
B116
SEMI-PRIVATE
B114
SEMI-PRIVATE
B112
IDF
B124LOUNGE
B125
SEMI-BARIATRIC
B111
SEMI-BARIATRIC
B110
SEMI-PRIVATE
B109
SEMI-PRIVATE
B107
SEMI-PRIVATE
B105
SEMI-PRIVATE
B103
SEMI-PRIVATE
B101
PRIVATE
B102
PRIVATE
B104
PRIVATE
B106
PRIVATE
B108
NURSE
B128
CORRIDOR
B127
TOILET
B126
CART/W-CHAIR
B133
TOILET
B134
CENTRAL
SHOWER
B135
ACTIVITY
B136
CAFE
B138
CORRIDOR
B137
SOILED
LINEN
B142
CLEAN
LINEN
B143
CLEAN
HOLDING
B144
MED
PREP
B141
NURSE
B140
NOURISHMENT
B139
PRIVATE
B156
PRIVATE
B154
PRIVATE
B152
PRIVATE
B150
CORRIDOR
B148
LOUNGE
B146
MDF
B186
PRIVATE
B161
PRIVATE
B163
PRIVATE
B165
PRIVATE
B167
SEMI-PRIVATE
B119
SEMI-PRIVATE
B117
SEMI-PRIVATE
B115
SEMI-PRIVATE
B113
DICTATION
B131
DICTATION
B132
MED
PREP
B129
OXYGEN
B130
34
8
35
35
2
5
22
28
10
11
23
3
34
35
35
35
36
37
34
34
HVAC FLOOR PLAN B
1/8"=1'-0"
Sheet Title:
Sheet Number:
Date: Issued for:
05-19-20 OWNER REVIEW
OAKRIDGE MANOR
NURSING AND
REHABILITATION
NSA Architects, Engineers, Planners
Copyright C 2020
Project Number:
Project Title:
Client:
DRAWN DESIGNED
CHECKED APPROVED
06-26-20 ISSUED FOR PERMITS
CONSULTING ENGINEERSMacMILLAN ASSOCIATES
BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET
www.macmillanassociates.com(989) 894-4300 F(989) 894-9930
06-05-20 95% REVIEW
FLOOR PLAN
HVAC PARTIAL
EAST
M-102
DM RAM
RAM RAM
216105.00
PIONEER HEALTH
CARE MANAGEMENT,
INC.
1
KEY NOTES:
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
4
21
24
9
33
29
38
38
35
37
35
35
20
39
39
39
35
\\m
aib
c1
9\d
ra
win
gs\1
6-N
SA
\2
01
9-1
62
0 O
akrid
ge
M
an
or N
ursin
g H
om
e M
ech
an
ica
l a
nd
S
tru
ctu
ra
l R
evie
w\D
OW
NL
OA
DE
D C
AD
F
ile
s\P
la
ns\M
-H
P0
1-B
.d
wg
, M
od
el, 7
/1
5/2
02
0 9
:1
2:5
4 A
M, sm
ag
uire
, 0
.1
25
:1
2
7/15/2020MAI # 2019-1620
Sheet Title:
Sheet Number:
Date: Issued for:
05-19-20 OWNER REVIEW
OAKRIDGE MANOR
NURSING AND
REHABILITATION
NSA Architects, Engineers, Planners
Copyright C 2020
Project Number:
Project Title:
Client:
DRAWN DESIGNED
CHECKED APPROVED
06-26-20 ISSUED FOR PERMITS
CONSULTING ENGINEERSMacMILLAN ASSOCIATES
BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET
www.macmillanassociates.com(989) 894-4300 F(989) 894-9930
06-05-20 95% REVIEW
PLAN
MECHANICAL ROOF
M-121
DM RAM
RAM RAM
216105.00
PIONEER HEALTH
CARE MANAGEMENT,
INC.
ROOF PLAN - MECHANICAL
1/16"=1'-0"
\\m
aib
c1
9\d
ra
win
gs\1
6-N
SA
\2
01
9-1
62
0 O
akrid
ge
M
an
or N
ursin
g H
om
e M
ech
an
ica
l a
nd
S
tru
ctu
ra
l R
evie
w\D
OW
NL
OA
DE
D C
AD
F
ile
s\ro
of\M
-1
21
.d
wg
, M
od
el, 7
/1
5/2
02
0 9
:1
3:0
4 A
M, sm
ag
uire
, 0
.0
62
5:1
2
7/15/2020MAI # 2019-1620
SCALE: NONE
BELT DRIVE CENTRIFUGAL
UPBLAST ROOF EXHAUSTER
SCALE: NONE
INTAKE AND EXHAUST HOOD
SCALE: NONE
TYPICAL AIR TERMINAL DEVICE
WITH REHEAT COIL
SCALE: NONE
TYPICAL CEILING RETURN AIR
GRILLE SOUND TRAP
SCALE: NONE
SUPPLY AIR RECTANGULAR
DUCT CONNECTION
SCALE: NONE
KITCHEN HOOD EXHAUST FAN
SCALE: NONE
VERTICAL FIRE DAMPER
SCALE: NONE
HORIZONTAL FIRE DAMPER
SCALE: NONE
FIRE AND SMOKE DAMPER
Sheet Title:
Sheet Number:
Date: Issued for:
05-19-20 OWNER REVIEW
OAKRIDGE MANOR
NURSING AND
REHABILITATION
NSA Architects, Engineers, Planners
Copyright C 2020
Project Number:
Project Title:
Client:
DRAWN DESIGNED
CHECKED APPROVED
06-26-20 ISSUED FOR PERMITS
CONSULTING ENGINEERSMacMILLAN ASSOCIATES
BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET
www.macmillanassociates.com(989) 894-4300 F(989) 894-9930
06-05-20 95% REVIEW
DETAILS
MECHANICAL
M-501
DM RAM
RAM RAM
216105.00
PIONEER HEALTH
CARE MANAGEMENT,
INC.
\\m
aib
c1
9\d
ra
win
gs\1
6-N
SA
\2
01
9-1
62
0 O
akrid
ge
M
an
or N
ursin
g H
om
e M
ech
an
ica
l a
nd
S
tru
ctu
ra
l R
evie
w\D
OW
NL
OA
DE
D C
AD
F
ile
s\S
ch
ed
ule
s\M
-D
T.d
wg
, M
od
el, 7
/1
5/2
02
0 9
:1
3:1
2 A
M, sm
ag
uire
, 0
.1
25
:1
2
7/15/2020MAI # 2019-1620
NOTES:
NOTES:
TYPICAL RTU SEQUENCE OF OPERATION:
··
···
··
·
··
·
··
·
··
·
·
··
·
··
·
···
·
··
·
·
·
·
·
·
·
SCALE: NONE
1
M-502
EXHAUST FAN MOTOR
STARTER I/O DIAGRAM
SCALE: NONE
2
M-502
EXHAUST FAN CONTROL DIAGRAM
SCALE: NONE
3
M-502
TYPICAL TERMINAL BOX W/ELECTRIC
REHEAT COIL CONTROL DIAGRAM
SCALE: NONE
4
M-502
TYPICAL RTU VFD CONTROL
DIAGRAM
SCALE: NONE
5
M-502
TYPICAL RTU CONTROL
DIAGRAM
SCALE: NONE
6
M-502
MUA-1 AND MUA-2 UNIT
CONTROL DIAGRAM
TYPICAL MUA UNIT SEQUENCE OF OPERATION:
··
···
··
·
··
·
··
·
··
·
·
··
·
··
·
·
·
Sheet Title:
Sheet Number:
Date: Issued for:
05-19-20 OWNER REVIEW
OAKRIDGE MANOR
NURSING AND
REHABILITATION
NSA Architects, Engineers, Planners
Copyright C 2020
Project Number:
Project Title:
Client:
DRAWN DESIGNED
CHECKED APPROVED
06-26-20 ISSUED FOR PERMITS
CONSULTING ENGINEERSMacMILLAN ASSOCIATES
BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET
www.macmillanassociates.com(989) 894-4300 F(989) 894-9930
06-05-20 95% REVIEW
CONTROLS
MECHANICAL
M-502
DM RAM
RAM RAM
216105.00
PIONEER HEALTH
CARE MANAGEMENT,
INC.
\\m
aib
c1
9\d
ra
win
gs\1
6-N
SA
\2
01
9-1
62
0 O
akrid
ge
M
an
or N
ursin
g H
om
e M
ech
an
ica
l a
nd
S
tru
ctu
ra
l R
evie
w\D
OW
NL
OA
DE
D C
AD
F
ile
s\M
ech
an
ica
l\M
-5
02
.d
wg
, M
od
el, 7
/1
5/2
02
0 9
:1
3:1
7 A
M, sm
ag
uire
, 0
.1
25
:1
2
7/15/2020MAI # 2019-1620
Sheet Title:
Sheet Number:
Date: Issued for:
05-19-20 OWNER REVIEW
OAKRIDGE MANOR
NURSING AND
REHABILITATION
NSA Architects, Engineers, Planners
Copyright C 2020
Project Number:
Project Title:
Client:
DRAWN DESIGNED
CHECKED APPROVED
06-26-20 ISSUED FOR PERMITS
CONSULTING ENGINEERSMacMILLAN ASSOCIATES
BAY CITY, MICHIGAN 48706714 EAST MIDLAND STREET
www.macmillanassociates.com(989) 894-4300 F(989) 894-9930
06-05-20 95% REVIEW
SCHEDULES
MECHANICAL
M-601
DM RAM
RAM RAM
216105.00
PIONEER HEALTH
CARE MANAGEMENT,
INC.
EXHAUST FAN SCHEDULE
TAG BASIS OF DESIGN LOCATION SERVICE TYPE CFM E.S.P. DRIVE
MOTOR DATA
COMMENTSHP VOLTS PHASE Hz
EF-1GREENHECK SQ-65-D
ROOM JC RM A112 IN-LNE 100 0.25 DIRECT
1/30
115 1 60
1,2,6
EF-2GREENHECK SQ-80-G
ROOM ELECTRICAL RM A111 IN-LNE 200 0.25 DIRECT
1/20
115 1 60
1,2,5
EF-3A GREENHECK CUBE-141-5 ROOF KITCHEN HOOD CENTR. UPBLAST 1500 1 BELT 1/2 208 3 60
1,2,3,8
EF-3B GREENHECK CUBE-161-5 ROOF KITCHEN HOOD CENTR. UPBLAST 1900 1 BELT 1/2 208 3 60
1,2,3,8
EF-4 GREENHECK GB-101-4 ROOF KITCHEN DISHWASHER CENTR. 600 0.75 BELT 1/4 115 1 60
1,2,3
EF-5 GREENHECK G-080 ROOF
TOILET RM A106, A107
CENTR. 150 0.25 BELT
1/20
115 1 60
1,2,3,6
EF-6 GREENHECK GB-081 ROOF SALON A124 CENTR. 400 0.25 BELT
1/6
115 1 60
1,2,3,6
EF-7 GREENHECK G-080 ROOF TOILET RM A117 CENTR. 200 0.25 DIRECT
1/30
115 1 60
1,2,3,7
EF-8 GREENHECK GB-220HP-20 ROOF
PRIVATE RM'S (NORTH)
CENTR. 3505 2 BELT 3.0 208 3 60
1,2,3,9
EF-9 GREENHECK USF-306-BI-X ROOF OXYGEN B130 CENTR. UTILITY 125 0.25 DIRECT
1/15
115 1 60
1,2,3,4,6
EF-10 GREENHECK GB-220-HP-20 ROOF
PRIVATE RM'S (SOUTH)
CENTR. 3075 2 BELT 2.0 208 3 60
1,2,3,10
EF-11 GREENHECK GB-131-3 ROOF COMMON AREAS CENTR. 1175 0.5 BELT 1/4 115 1 60
1,2,3,6
EF-12 GREENHECK SQ-80-G ROOM MECHANICAL RM B187 IN-LNE 200 0.25 DIRECT 1/20 115 1 60 1,2,5
NOTES:
1) PROVIDE DISCONNECT SWITCH.
2) PROVIDE BACK-DRAFT DAMPER, AND BIRDSCREEN WHERE APPLICABLE.
3) PROVIDE ROOF CURB.
4) IN-LINE SPARK RESISTANT, ALUMINUM CONSTRUCTION.
5) PROVIDE THERMOSTAT. ( FAN ENERGIZED AT ROOM TEMPERATURE GREATER THAN 95 DEGREE). PROVIDE SUPPORT WITH VIBRATION ISOLATORS.
6) PROVIDE WITH TIMER
7) INTERLOCK WITH LIGHT SWITCH
8) INTERLOCK WITH HOOD's HEAT SWITCH AND MAU-3
9) INTERLOCK WITH MAU-1
10) INTERLOCK WITH MAU-2
Variable Air Volume Single Duct Terminal Units
Schedule
Unit Tags
RTU
Quantity
Airflow
Electric Heating
Notes
Unit model
Primary inlet
Design
cooling
airflow
Min cooling
airflow
Valve
heating
airflow
Coil heating
capacity
Electric
heater
kilowatt
Electric
heater
voltage
Electric heater
stage
EDB (deg F) LAT (deg F)
cfm cfm cfm MBh
VAV-1 RTU-1 1 VCEF
10" (254mm)
1375 415 685 27.32 8 208/3 1 55 92 1 thru 7
VAV-2 RTU-1 1 VCEF
6" (152mm)
500 150 250 10.24 3 208/3 1 55 93 1 thru 7
VAV-3 RTU-1 1 VCEF
5" (127mm)
255 100 125 5.12 1.5 208/1 1 55 93 1 thru 7
VAV-4 RTU-1 1 VCEF
14" (356mm)
2400 720 1200 47.81 14 208/3 1 55 92 1 thru 7
VAV-5 RTU-1 1 VCEF
12" (305mm)
1630 500 825 34.15 10 208/3 1 55 93 1 thru 7
VAV-6 RTU-1 1 VCEF
14" (356mm)
2610 785 1305 51.22 15 208/3 1 55 91 1 thru 7
VAV-7 RTU-4 1 VCEF
6" (152mm)
365 110 185 6.83 2 208/1 1 55 89 1 thru 7
VAV-8 RTU-4 1 VCEF
12" (305mm)
1780 525 900 37.56 11 208/3 1 55 93 1 thru 7
VAV-9 RTU-4 1 VCEF
8" (203mm)
625 190 315 13.66 4 208/3 1 55 95 1 thru 7
VAV-10 RTU-4 1 VCEF
5" (127mm)
300 90 150 5.12 1.5 208/1 1 55 86 1 thru 7
VAV-11 RTU-4 1 VCEF
5" (127mm)
325 100 175 6.83 2 208/1 1 55 91 1 thru 7
VAV-12 RTU-4 1 VCEF
8" (203mm)
660 200 330 13.66 4 208/3 1 55 93 1 thru 7
VAV-13 RTU-2 1 VCEF
8" (203mm)
900 270 450 18.78 5.5 208/3 1 55 93 1 thru 7
VAV-14 RTU-2 1 VCEF
10" (254mm)
1015 305 500 20.49 6 208/3 1 55 93 1 thru 7
VAV-15 RTU-2 1 VCEF
12" (305mm)
1420 425 710 27.32 8 208/3 1 55 90 1 thru 7
VAV-16 RTU-2 1 VCEF
10" (254mm)
1110 333 555 22.2 6.5 208/3 1 55 92 1 thru 7
VAV-17 RTU-2 1 VCEF
6" (152mm)
400 120 200 8.54 2.5 208/1 1 55 94 1 thru 7
VAV-18 RTU-3 1 VCEF
10" (254mm)
950 285 475 18.78 5.5 208/3 1 55 91 1 thru 7
VAV-19 RTU-3 1 VCEF
8" (203mm)
600 180 300 11.95 3.5 208/3 1 55 92 1 thru 7
VAV-20 RTU-3 1 VCEF
6" (152mm)
450 135 225 10.24 3 208/3 1 55 97 1 thru 7
VAV-21 RTU-3 1 VCEF
10" (254mm)
930 280 465 18.78 5.5 208/3 1 55 92 1 thru 7
VAV-22 RTU-3 1 VCEF
10" (254mm)
1000 300 500 20.49 6 208/3 1 55 93 1 thru 7
NOTES:
1
Units to be Trane (or equal by Titus) model, size, and configuration as indicated in schedule and on drawings
2
Provide with zone temperature sensor
3
Provide with factory-wired discharge air temperature sensor
4
Provide factory-mounted and pre-programmed, pressure-independent, BACnet DDC controller with airflow measurement
5 Provide unit-mounted disconnect
6 Provide with SCR Electric Heat Control
7
Provide with Factory Control Power Transformer
LOUVER SCHEDULE
TAG
BASIS OF DESIGN
SERVING CFM INTAKE / RELIEF
DIMENSIONS (INCHES)
NOTESMANUFACTURER MODEL WIDTH HEIGHT DEPTH
L-1 GREENHECK GCI-202 MECH/ELECTRICAL ROOM 200 INTAKE 14 12 6
1,2,3,4
L-2 GREENHECK GCE-202 MECH/ELECTRICAL ROOM 200 EXHAUST 14 12 6
1,2,5
NOTES:
1) LOUVER COLOR TO MATCH ARCHITECTURAL EXTERIOR.
2) INSTALL LOUVERS PER MANUFACTURER'S RECOMMENDATION. PROVIDE BIRD AND INSECT SCREEN, AND EXTENDED SILL.
3) PROVIDE MOTORIZED DAMPER INTERLOCKED WITH EF.
4) LOCATE AT 18" A.F.F.
5) LOCATE AT 18" BELOW CEILING
HVAC Unit Schedule
TAG BASIS OF DESIGN AREA SERVED
HEATING CAPACITY COOLING CAPACITY SUPPLY FAN
FILTERS RATING
MERV ELECTRICAL
MIN OA
CFM
WEIGH
T
(LBS)(±
5%)
NOTES/ACCESSORIESTYPE
INPUT
MBH
OUTPUT
MBH
TOTAL
MBH
SENS
MBH
EER
(NOTE-5)
DRIVE CFM ESP HP PRE FINAL
VOLTS/P
HASE FLA AMPS MCA AMPS MOP AMPS
RTU-1 AAON RN-025-8-0-EA09-3CB COMMON AREAS
GAS
MODULATING
540 432 306.74 233.55 11.3 DIRECT 8770 2.5 15 MERV 8 MERV14 208/3/60 163 175 200 2440 28861,2,3,4,5,6,7,8,9
RTU-2 AAON RN-013-8-0-EB09-3GB COMMON AREAS
GAS
MODULATING
292.5 234 160.37 128.78 12.1 DIRECT 4845 2.5 5 MERV 8 MERV14 208/3/60 74 79 100 1078 19711,2,3,4,5,6,7,8,9
RTU-3 AAON RN-011-8-0-EB09-3FB COMMON AREAS
GAS
MODULATING
195 156 131.54 105.22 12.7 DIRECT 3930 2.5 5 MERV 8 MERV14 208/3/60 55 59 70 766 18101,2,3,4,5,6,7,8,9
RTU-4 AAON RN-015-8-0-EA09-3GB COMMON AREAS
GAS
MODULATING
292.5 234 184.14 127.61 11.1 DIRECT 4055 2.5 5 MERV 8 MERV14 208/3/60 80 86 110 1735 19271,2,3,4,5,6,7,8,9
MAU-1 AAON RN-015-8-0-EA09-36B RESIDENT UNITS
GAS
MODULATING
390 315.9 202.86 84.85 11.1 DIRECT 2950 2 3 MERV 8 MERV14 208/3/60 74 80 100 2950 19291,4,5,6,7,8,9,10,12
MAU-2 AAON RN-015-8-0-EA09-36B RESIDENT UNITS
GAS
MODULATING
390 315.9 202.86 84.85 11.1 DIRECT 2950 2 3 MERV 8 MERV14 208/3/60 74 80 100 2950 19291,4,5,6,7,8,9,11,12
MAU-3 AAON RN-015-8-0-EA09-36B KITCHEN
GAS
MODULATING
390 315.9 209.39 87.68 11.1 DIRECT 3300 1.5 3 --- MERV 13 208/3/60 74 80 100 3300 192913,14,15
NOTE 2: EXTERNAL STATIC PRESSURE CALCULATED FOR: FILTERS, SUPPLY AND RETURN DUCTWORK.
NOTE 3: UNIT TO BE BOTTOM SUPPLY/ RETURN
NOTE 4: PROVIDE SMOKE DETECTORS FOR S.A./R.A. DUCTWORK
NOTE 5: EER RATINGS SHOWN FOR UNITS AT ARI CONDITIONS
NOTE 6: PROVIDE WITH ECONOMIZER, THERMOSTAT, DISCONNECT SWITCH, MODULATING HOT GAS REHEAT, CO2 SENSORS.
NOTE 7: PROVIDE INSIDE DUCT THERMOSTAT, DISCONNECT SWITCH ON EACH POWER SOURCE, MODULATING HOT GAS REHEAT.
NOTE 8: MANUFACTURER'S INSTALLATION INSTRUCTIONS MUST BE AVAILABLE AT THE JOB SITE BEFORE, DURING, AND AFTER UNITS INSTALLATION.
NOTE 9: PROVIDE FILTER IN ROOF CURB.
NOTE 10: INTERLOCK MAU-1 WITH EF-8.
NOTE 11: INTERLOCK MAU-2 WITH EF-10.
NOTE 12: PROVIDE MAU-1 AND MAU-2 WITH STAINLESS STEEL HEAT EXCHANGER.
NOTE 13: INTERLOCK MAU-3 WITH EF-3A AND EF-3B.
NOTE 14: PROVIDE AND INSTALL RTU/MAU CONTROL PANEL. COORDINATE WITH OWNER FOR FINAL LOCATION.
NOTE 15: PROVIDE DISCONNECT SWITCH FOR MAU-3.
ELECTRIC UNIT HEATER SCHEDULE
TAG
BASIS OF
DESIGN
LOCATION HEATING CAPACITY
ELECTRICAL
COMMENTS
VOLTS/PHASE
EUH-1
Q-MARK
MUH0381 MECH/ELECTRICAL RM 3000 WATTS 208/1 1
NOTE 1: UNIT MOUNTED VERTICALLY, HEAVY GAUGE STEEL HOUSING, PULL THROUGH AIR FLOW, ENCLOSED FAN
MOTOR, ALUMINUM-FINNED, COPPER CLAD STEEL SHEATH HEATING ELEMENT, ADJUSTABLE LOUVER, UL, NEC,
AND OSHA, PROVIDED FACTORY UNIVERSAL MOUNTING BRACKET, INTEGRAL ADJUSTABLE THERMOSTAT,
DISCONNECT SWITCH.
ELECTRIC RADIANT CEILING PANEL SCHEDULE
TAG
BASIS OF
DESIGN LOCATION HEATING CAPACITY
ELECTRICAL
COMMENTSVOLTS/PHASE
ERCP-1MARKELRCP127
EXTERIOR RESTROOMS 750 120/1 1,2,3
NOTE 1: PROVIDE WITH ET9 SERIES MODEL AET9DWTS LINE VOLTAGE THERMOSTAT, DOUBLE POLEWITH POSITIVE OFF AND SINGLE KNOB WITH 50 TO 90 DEGREE F RANGE.NOTE 2: 2'x4' PANEL FOR DRYWALL CEILING WITH SILICONE SEALED METAL PARTS FOR HIGHHUMIDITY APPLICATIONS.NOTE 3: ERCP SHALL BE FURNISHED BY MECHANICAL CONTRACTOR AND INSTALLED AND WIRED BYELECTRICAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE INSTALLATION OFTHE NEW RADIANT CEILING PANEL WITH THE ELECTRICAL CONTRACTOR.
(PTAC) Packaged Terminal Air Conditioning Unit Schedule
TYPE
MANUFACTURER
MODEL AREA SERVED
HEATING CAPACITY COOLING CAPACITY
SUPPLY
FAN ELECTRICAL
MIN OA
CFM
DIMENSIONS
WxHxD NOTESCORD KW BTUH NOMINAL MBH CFM VOLTS/PHASE MCA AMPS MOP AMPS
PTAC-1 LG/ LP123HDUC RESIDENT RM 20 AMP 3.2
10,900 11,900
420 208/1 19.8 20 70 42x16x21
1,2,3
PTAC-2 LG/ LP093HDUC RESIDENT RM 20 AMP 3.2
10,900 10,000
270 208/1 19.8 20 60 42x16x21
1,2,3
PTAC-3 LG/ LP153HDUC RESIDENT RM 30 AMP 4.7
15,700 14,900
420 208/1 28.3 30 70 42x16x21
1,2,3
NOTE 1: UNIT SELECTIONS ARE BASED ON 95°F DB AND 75°F WB OUTSIDE AIR CONDITIONS.
NOTE 2: PROVIDE WALL SLEEVE, ARCHITECTURAL OUTDOOR AIR GRILLE, DISCONNECT SWITCH, WALL THERMOSTAT, FACTORY CORD AND PLUG.
NOTE 3: PROVIDE MANUFACTURER'S STANDARD CLEANABLE OR REPLACEABLE FILTER.
ELECTRIC CABINET HEATER SCHEDULE
TAG
BASIS OF
DESIGN LOCATION HEATING CAPACITY
ELECTRICAL
COMMENTSVOLTS/PHASE
ECH-1MARKEL
E3383D-RP ENTRANCE DOOR 1500 WATTS 120/1 1,2
NOTE 1: INTEGRAL ADJUSTABLE THERMOSTAT, DISCONNECT SWITCH
NOTE 2: CEILING RECESSED
GRILLE, REGISTER AND DIFFUSER SCHEDULE
TAG BASIS OF DESIGN TYPE CFM RANGE
NECK SIZE (IN.) LAY-IN MODULE (IN.) SURFACE MODULE (IN.)
MAX NC NOTES
S-1 TITUS, 272RS SUPPLY 50-150 10x6 -- 12x8 30 1,2
S-2 TITUS, TMS SUPPLY 50-150 6 12x12 -- 30 1,2
S-3 TITUS, TMS SUPPLY 50-150 6 24x24 -- 30 1,2
S-3A TITUS, TMS-AA SUPPLY 50-150 6 24x24 -- 30 5
S-4 TITUS, TMS SUPPLY 150-300 8 24x24 -- 30 1,2
S-4A TITUS, TMS-AA SUPPLY 150-300 8 24x24 -- 30 1,2
S-5 TITUS, TMS SUPPLY 300-500 10 24x24 -- 30 1,2
S-6 TITUS, TDC-FR SUPPLY 50-150 6 12x12 -- 30 1,2,5
S-7 TITUS 272RS SUPPLY 50-150 6 -- 8x8 30 1,2
S-8 TITUS 272RS SUPPLY 300-500 10 -- 12x8 30 1,2
S-9 TITUS TBD-10 SUPPLY 100-250 8 -- -- 30 2,4
R-1 TITUS. 350RL RETURN 0-500 SEE DWG -- 12x8 30 1,2
R-2 TITUS, PAR RETURN 0-1800 SEE DWG -- 24x24 30 1,2
R-3 TITUS. 350RL RETURN 0-1000 SEE DWG -- 18x12 30 1,2
E-1 TITUS, 50F EXHAUST 0-150 6 -- 12x12 30 1,2
E-2 TITUS, 50F EXHAUST 0-150 8 -- 12x12 30 1,2
E-3 TITUS, 50F EXHAUST 0-500 10 -- 12x12 30 1,2
E-4 TITUS, PAS-FR EXHAUST 0-150 6 12x12 -- 30 1,2,5
NOTE 1: OPPOSED BLADE VOLUME DAMPER
NOTE 2: WHITE FINISH
NOTE 3: BLANK OFF 1 SIDE (FACING WALL)
NOTE 4: PLENUM SLOT DIFFUSER, 48" LONG, STEEL, 1 SLOT @ 1" WIDTH
NOTE 5: FIRE RATED
DOOR HEATER SCHEDULE
TAG BASIS OF DESIGN LOCATION HEATING CAPACITY
ELECTRICAL
COMMENTSVOLTS/PHASE
DH-1 BERNER ARC16-2084EX-160 VESTIBULE 16kW 208/3 1,2
NOTE 1: CEILING RECESSED DOOR HEATER.NOTE 2: PROVIDE WITH CONTROLS TO HOLD SPACE TEMP DURING INACTIVITY AND DOOR CONTACTS TO ACTIVATEHEATER WHEN DOOR OPENS.
SINGLE HVAC SPLIT SYSTEM SCHEDULE
TAG
COOLING
TONS
TOTAL
COOLING
(BTUH)
SEER REFRIGERANT
TOTAL
HEATING
INDOOR UNIT OUTDOOR UNIT ELECTRICAL BASIS OF DESIGN
NOTES
INDOOR OUTDR CFM HI/MED/LOW LOCATION FILTER LOCATION FAN VOLTS/ø/HZ FLA
INDOOR
MODEL
OUTDOOR
MODEL
AC-1AC-2AC-3AC-4
CU-1CU-2CU-3CU-4
2 25,200 17 134a - 559/475/390A108, B139,
B174,B124,B186 WASHABLE ROOF PROP. 208/1ø/60 16.9 PANASONICS-26PK1U6
PANASONICU-26PS1U6
1,2,3,4,5,6
NOTES:
1) LOW AMBIENT CONTROL, MICROPROCESSOR CONTROLS.
2) PROVIDE THERMOSTAT, (WEATHER DUTY) DISCONNECT SWITCH, REMOTE CONTROLLER.
3) PROVIDE INDOOR WALL SUPPORT, INSTALL PER MANUFACTURER RECOMMENDATION.
4) PROVIDE OUTDOOR, SUPPORT SIMILAR TO THYBAR MODEL TEMS-3 12" HIGH.
5) PROVIDE PROPERLY SIZED REFRIGERANT LINE SET. INSTALL PER MANUFACTURER RECOMMENDATION.
6) PROVIDE CONDENSATE PUMP
\\m
aib
c1
9\d
ra
win
gs\1
6-N
SA
\2
01
9-1
62
0 O
akrid
ge
M
an
or N
ursin
g H
om
e M
ech
an
ica
l a
nd
S
tru
ctu
ra
l R
evie
w\D
OW
NL
OA
DE
D C
AD
F
ile
s\S
ch
ed
ule
s\M
-S
H.d
wg
, M
od
el, 7
/1
5/2
02
0 9
:1
3:2
7 A
M, sm
ag
uire
, 1
2:1
2
7/15/2020MAI # 2019-1620