general catalogue - · pdf file4 rc group spa • general catalogue • 155.en.0504...

306
...since 1963 g e n e r a l catalogue equipment and systems for air conditioning

Upload: lamdat

Post on 15-Feb-2018

384 views

Category:

Documents


14 download

TRANSCRIPT

Page 1: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

. . . s i n c e 1 9 6 3

g e n e r a lc a t a l o g u e

e q u i p m e n t a n d s y s t e m s f o r a i r c o n d i t i o n i n g

Page 2: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES
Page 3: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

3RC GROUP SpA • General Catalogue • 155.EN.0504

Soluzioni Affidabiliper

Applicazioni CriticheGeneral Index

INTRODUCTION 4

COMPANY PRESENTATION 10

REFERENCES 18

Over 22

Under 36

Displacement 52

Flexiclim System 60

Heat Pumps 66

Over 72

Displacement 80

Air cooled 88

Free-Cooling 138

Heat pumps 172

Multifunction 218

Water cooled 236

Evaporating units 254

Heat pump evaporating units 268

LIQUID CHILLERS IN 134a VERSION 274

AIR COOLED CONDENSERS AND DRY COOLERS 290

AIR CONDITIONERS FOR HI-TECH.AND COMFORT APPLICATIONS

AIR CONDITIONERS FORINFORMATION TECHNOLOGYAND COMMUNICATION

LIQUID CHILLERS

Page 4: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

4 RC GROUP SpA • General Catalogue • 155.EN.0504

Introduction

INFORMATION TECHNOLOGY

MOBILE COMMUNICATION

TELECOMMUNICATION

BANKS & HI - TECH. OFFICES

INDUSTRIAL PROCESSES

The products described throughout this catalogue are the offspring ofa 40-year experience in designing and building of air conditioning units andliquid chillers.

Our production quality is guaranteed by the use of high reliability com-ponents and by continuous investments allowing our company to make useof the most advanced technologies.

The commitment in research and in our organisation grants a continu-ous growth of our products to meet the users’ requirements.

Company professional competence lets us offer each customer a mostqualified and considerable business relation.

The images here displayed generally summarize the different applica-tions to which our products are dedicated, starting from: Hi-Tech. to Com-fort applications, passing through Industry and Leisure.

Every application is characterized by precise working and plant logicsand all of them are joined by the one and only fundamental problems: theapplication criticality.

Critical Applications are defined by their requirement of which full “Con-tinuity & Quality” of service are not seen as optional but are demanded asfundamental to the service itself.

These applications normally operate 24 hours a day, 7 days a week, 12months a year.

They range from vital services supported by sophisticated electronicsystems, through installations providing information to the business com-munity and general public amenities designed to improve the quality of ourday to day lives.

Most of today’s products available on the market, especially waterchillers for support of room air conditioning units are designed and manu-factured to be used for Comfort Cooling applications, requiring only sea-sonal cooling during the summer period. Failure of these systems resultsonly in minimal personal discomfort to the occupants.

RC product range is specifically designed and manufactured to meetthe most demanding requirements of the Critical Application Project type interms of 24 hour a day, all year round operation, energy efficiency andbuilt-in redundancies.

RC equipment production has always been directed towards air condi-tioning and liquid refrigeration systems for applications with high criticalcontent. The first units manufactured in 1963, were in fact 3 Close ControlCabinet Units for the computing department of a Bank. Since then RC hasdeveloped significant expertise both in the system evaluation, equipmentmanufacture and in the research of suitable and innovative solutions. Thisexperience has contributed to a continuous improvement of the product ofwhich this issue of the RC Catalogue is the summary.

Technology, absolute reliability, high quality and the corresponding ex-acting attention to the various system requirements are the main ingredi-ents of the proposed wide product range.

Page 5: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

5RC GROUP SpA • General Catalogue • 155.EN.0504

Soluzioni Affidabiliper

Applicazioni CriticheIntroduction

LEISURE AND ENTERTAINEMENT

SHOPPING CENTRES

TRANSPORT

HOSPITALS

SMALL OFFICES & HOME

The commitment of RC finds a reply in the thousands of product deliv-eries, destined to these types of installations. These particular applica-tions need reliable equipment in order to guarantee uninterrupted work-ing and to reduce the technical assistance required for routine mainte-nance procedures.

RC uses this design and manufacturing normally and generally; the prod-uct, specific for critical applications, is strictly mass-produced to ensurerepeatable high quality products as shown in the RC catalogues.

RC has always been at the leading edge of applied research and thenew technologies to improve its production capabilities.

This enterprise policy has given important results, further promotingRC products as a market leader on the international stage together withan International Worldwide Sales and After-Sales Network. Competent andalways well-informed engineers are always available to give current prod-uct and system application advice, best suited to the Client’s specific projectrequirements.

RC progressive sales network covers the whole world in an extensiveway. This network is supported by a widespread and qualified ServiceOrganization that guarantees an excellent after-sales service with reac-tion times corresponding only to the importance of that demanded by theClient’s service requirements.

The confirmation of RC continuing product quality is the systematicdevelopment of its products, in the applications where the system reliabil-ity is a priority.

To allow a simple use of this catalogue we have divided the whole pro-duction following the already tested logic applied to the company Internetsite www.rcgroup.it.

This partition helps to identify a specific product in a simple and intui-tive way.

A range of “plus point” (short descriptions reporting particular char-acteristics) supported by detailed images highlights the product particu-lar characteristics. The “plus point” are not strictly bound to the product,but they highlight the characteristics of a whole range; basically they arecontained throughout the pages detailing the specific product series.

The so highlighted Plus Points and with “®” symbol identify a RC GROUPinternational PATENT.

In the following pages we summarize the entire manufacturing and theplus contained in the catalogue, identifying them with a short description.

Page 6: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

6 RC GROUP SpA • General Catalogue • 155.EN.0504

Plus Points List

PLUS POINTS

3SpeedAdaptiveRange

Air-Rail®ColdLayerCool4Free

CoolingDensityPlusDBelt

DirectControlDirectCool

DisplacementDNA@RC

Easy@ServEasyFit

EasyLinkEfficientFlow

EMCExtraCircuit

FastHeatFlexiBox

Flexiclim®ForcedDehumidification

HeatPackageHoneyCombMade2Last

MateMistral®

MP.COMNoiseControl

PerformancePlusProHumid

PureAirQuickStart

RCProactiveSave

ServiceFastSideBySide

SleepWellSmartLink

SolutionSpaceSaver

SynergyTopRate

TwinPowerVCoil

WindowMateYRFan

Description of “Plus Points” related to AIR CONDITIONING UNITS

3 speed air treatment fansIt satisfies every plant needsPatended induction system on displacement air deliveryProprietary RC technology for displacement air delivery optimizationIndirect Free-Cooling for units with built-in water condensing systemThe best ratio between occupied space and cooling capacityBelt drive system for air treatment fansProportional humidifier controlled by the microprocessorDirect Free-Cooling with proportional damperDisplacement air deliveryBig precision air conditioners technology shifted to small unitsAir filters removal from the front of the unit without opening any panelEasy to reposition or extend without technicians interventionKit for air suction and outdoor exhaustionFans speed regulation for displacement air deliveryElectromagnetic suitabilitySystem for available energy employment, or for an integrated backupLow thermal inertia electric heating system, with no ionization on airNoiseless terminal units with no maintenance needPatented Flexiclim SystemDehumidification without air flow modificationsHot water heating with 3 way valveOptimized air distribution grille for displacement air deliveryHousing designed to last in time and in bad weatherCondensing control system with speed modulation of condensers fansPatended control logic for displacement air delivery systemsThe new RC microprocessors generationNoise deading cups for compressors noise reductionTandem SCROLL type compressorsElectronic controlled proportional humidifierFlexible ducting for terminal units connectionEasy and quick unit start-upContinuity of work even in emergency situationsAir treatment fans speed modulation according to the loadStandard maintenance with the unit in working modeSerial installation to obtain high cooling capacities in reduced spaceLowest noise emission during the nightLAN network with no additional componentsMaximum energy saving with Heat Hunter units and Optimizer systemInspection and maintenance operations from the front of the unitSynergy within displacement units and traditional onesMaximum energy saving for each chilled water unitDouble electric feeding“V” shaped cooling coilsUnder window installationDirect or belt drive ventilation systems

Page 7: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

7RC GROUP SpA • General Catalogue • 155.EN.0504

Soluzioni Affidabiliper

Applicazioni CritichePlus Points List

PLUS POINTS

4in40AdaptiveRangeAntirumbleBufferTankCentriCoolingDensityPlusDNA@RCDual®Easy@ServEMCFreezeProtectionFullHeatReclaim (FHR)Gamma ELN (Super Silent)GlycolFreeIDEA®Idrocompl®KeepCoolIdronicPackMade2LastMateMaximo&DualMP.COMMP99MyNoiseNoFreezeNoiseBoxOptimizer®PerformancePlusPump&PressurePumpStationQuickStartRCProactiveSCR&MP99ScrewScrollServiceFastSideBySideSleepWellSpaceSaverTR88Zytel

Description of “Plus Points” related to LIQUID CHILLERS

4 units in a 40 feet containerIt satisfies every plant needsAnti rumble rigid base frame

Water buffer tankCentrifugal fan unit version for indoor and/or ducted installations

The best ratio between occupied space and cooling capacityBig precision liquid chillers technology shifted to small units

The most powerful reciprocating compressor in the worldAccess to all components through comfortable frontal panels

Electromagnetic suitabilityEvaporator anti-freeze protection controlled by the microprocessor

Integrated system for total condensing heat reclaimTotal product redesign to minimize the noise emissions

Free-Cooling integrated system with no need of antifreezingPatented defrosting system with dynamic scanning of working parameters

Patented evaporator, expansion and water tank in a sole casingWorking continuity with high outdoor temperatures

Pump and tank in a sole package without plan measurements increaseHousing designed to last in time and in bad weather

Condensing control system with speed modulation of condensers fansFree-Cooling packaged liquid chillers up to 1.610 kW

The new RC microprocessors generation with AUTOADAPTIVE logicMicroprocessor system equipped with RC PROACTIVE proprietary logic

Range of solutions to control the noise emissionsAntifreeze system preventing the water in the evaporator from freezing

Compressors acoustic deading systemPatented system for variable water flow plants

Tandem SCROLL type compressors to grant the maximum energy efficiencyCirculation pump with water plant pressure control

Pump station inside the unit with no size increaseEasy and quick unit start-up

Continuity of work even in emergency situationsSCR system optimizing total and patial Free-Cooling cyclesDouble screw helicoidal compressors with high efficiency

The most modern technology in the field of medium/small compressors sizeStandard maintenance with the unit in working mode

Serial installation to obtain high cooling capacities in reduced spaceLowest noise emission during the night

Inspection and maintenance operations from the front of the unitSupervision and remote control system; up to 8 unità

Air delivery pipes made of patented plastic material

Page 8: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

8 RC GROUP SpA • General Catalogue • 155.EN.0504

Plus Points List

AIR CONDITIONERS AIR CONDITIONERS FORINFORMATION TECHNOLOGY

AND COMMUNICATION

CONS

OLE O

VER

PEGA

SUS

OVER

COM

PACT

OVE

RCO

NSOL

E UND

ERPE

GASU

S UN

DER

COM

PACT

UND

ERHA

ET H

UNTE

RFL

EXIC

LIM O

VER

FLEX

ICLIM

UND

ERPE

GASU

S OV

ER H

P

MIN

IPAC

OVER

ENER

TEL O

VER

EBER

GY S

PLIT

OVE

REN

ERTE

L DL

PEGA

SUS

DL

3Speed • • • • • • • • •AdaptiveRange • • • • • • • • • • • • • • •

Air-Rail® •ColdLayer •

Autoadaptive •Cool4Free • •

CoolingDensityPlus • • • • • • • • • • • • • • •DBelt • • • • •

DirectControl • • • • • • • • • •DirectCool • • • • • •

Displacement • • •DNA@RC • •

Easy@Serv • • •EasyFit • •

EasyLink • • •EfficientFlow •

EMC • • • • • • • • • • • • • • •ExtraCircuit • •

FastHeat • • • • • • • • • • • • • • •FlexiBox • •

Flexiclim® • •ForcedDehumidification • • • • • • • • •

HeatPackage • • • • • • • • •HoneyComb •Made2Last • • • • • • • • • • • • • • •

Mate • • • • • • • • • • •Mistral® •

MP.COM •NoiseControl • • •

PerformancePlus • • •ProHumid • • • • • • • • • •

PureAir • •QuickStart • • • • • • • • • • • • • • •

RCProactive • • • • • • • • • • • • • • •Save • • • • • •

ServiceFast • • • • • • • • • • • • • • •SideBySide •

SleepWell • • • • •SmartLink • • • • • • • • • • • • • • •

Solution •SpaceSaver • • • • • • • • • • • • • • •

Synergy •TopRate • • • • • • • • • •

TwinPower • • • • •VCoil • •

WindowMate • •YRFan • • •

Page 9: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

9RC GROUP SpA • General Catalogue • 155.EN.0504

Soluzioni Affidabiliper

Applicazioni CritichePlus Points List

LIQUID CHILLERS

AIR COOLED WATER COOLED

EASY

CILL

I.IDR

OCOM

PLUN

ICO

MOD

ULO

MAX

IMO

EASY

.PCI

LLI.I

DROC

OMPL

.PRE

VERS

O.P

MOD

ULO.

PM

ULTI

PLO

AQUA

.IDRO

COM

PLCO

DLPA

CKFR

IGO

DIVI

.IDRO

COM

PL.P

TEAM

.MAT

E

• • 4in40• • • • • • • • • • • • • • • AdaptiveRange• • • • • • Antirumble• • • • • • • • • • BufferTank

• • • • • • • Centri• • • • • • • • • • • • • • • CoolingDensityPlus• • • • • • • DNA@RC

• • • • • • Dual®• • • • • • • • • • • Easy@Serv• • • • • • • • • • • • • • • EMC• • • • • • • • • • • • • • FreezeProtection

• • • • FullHeatReclaim (FHR)• • • • • Gamma ELN

• GlycolFree• • • • • • IDEA®

• • • • Idrocompl®• KeepCool• • • • • • IdronicPack• • • • • • • • • • • • • • • Made2Last• • • • • • • • • • • Mate

• Maximo&Dual• • • MP.COM

• • • • • • • MP99• • • • • • • • MyNoise

• • • • • • • • • • • • • • NoFreeze• • • • NoiseBox

• Optimizer®• • • • • • • • • • • • PerformancePlus• • • • • • Pump&Pressure

• • • • • • PumpStation• • • • • • • • • • • • • • • QuickStart• • • • • • • • • • • • • • RCProactive

• SCR&MP99• • • • Screw

• • • • • • • • • • • • Scroll• • • • • • • • • • • • • • • ServiceFast

• • SideBySide• SleepWell

• • • • • • • • • • • • • • • SpaceSaver• • • • • • • TR88• • • • • Zytel

Page 10: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

10 RC GROUP SpA • General Catalogue • 155.EN.0504

Freely taken from the article which appeared in “CDA-Condizionamento dell’AriaRiscaldamento Refrigerazione” of November 1999.

Almost all the entrepreneurial realities, which we have had the opportu-nity to become acquainted with on the occasion of our interviews, have incommon determination and initiative, qualities which put the Italian workworld in a positive light even though it is still so controversial and tor-mented.Every company, however, has its own peculiarities that can be discoveredduring interviews or felt in the air having just crossed the threshold.In the case of RC Group the first sensation was one of serenity, or better, ofefficiency without agitation. Tranquil its location at the foot of the Pavesehills, inviting its headquarters, serene the attitude of its office workersand factory workers, neat and tidy its plant. The activity is intense but, aswe will see, governed by organization and common sense.Roberto Caciolli, who gave us the interview, is one of the three owners, allin the management of the company, together with his brother Fabrizio andtheir friend Sergio Gallina.

History always helps us to understand the present and in the evolution ofyour Group, I believe it is almost indispensable to know the beginnings.The Company was established in 1963 with the aim of producing air conditioningand refrigeration systems for critical applications. One of the first products wasan air conditioner for a data processing centre for San Paolo Bank of Torino(probably one of the first air conditioner for data processing centres realized inItaly).

This typology required a lot of know-how at all levels, from the knowledgeof the problem to solve to the ability to choose the most appropriate tech-nological applications.Throughout the sixties the company grew slowly, without a real array ofproducts for mass-production, but producing on order what the marketrequired of the refrigeration and conditioning of the times, designing andrealizing personalized machines on the basis of the customer’s needs.The experience of those first years in its life profoundly influenced thecompany philosophy, making flexibility and speed of response to the marketneeds the cards which are still winning today.A first turn took place at the beginning of the seventies when we presenteda line of air conditioners especially dedicated to DPC and an agreement wassigned with a Multinational Leader in the computer field that wanted tooffer turnkey solutions to its clients.Not only the computer part was offered, but also all the equipment for thesite and whatever was necessary for the correct functioning of the ma-chines contained in it.

1963 1970 1980

The Company was estabilished in 1963with the aim of producing air condition-ing and refrigeration systems for criti-cal applications.The experience of those first years inits life profoundly influenced the com-pany philosophy, making flexibility andspeed of response to the market needsthe cards which are still winning today.

Company presentation

1963the first air conditioner for data processing centres

Page 11: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

11RC GROUP SpA • General Catalogue • 155.EN.0504

Soluzioni Affidabiliper

Applicazioni Critiche

The agreement permitted RC Condizionatori to consolidate and presentingitself at the beginning of the eighties on the European market with a well-defined catalogue of specific products for DPC.In 1982 we created a distribution network, covering initially all of westernEurope with remarkable success right from the beginning, because in thatmoment the companies in the market were very few. It was a rapidly-growing market, with a high technological component, suitable for smalland medium-sized companies, rapid and flexible, that made it possible torealize extremely interesting economic results.The profits in this way were constantly reinvested, permitting the com-pany to multiply its proceeds of sales every year from 1978 to 1989, al-ways maintaining unchanged the quality of its products, of the service of-fered to its clients and of the company organization.

In the years immediately following there was a great crisis in the EDP field;did your orientation change?After 1989 the processing understood as a central unit of data processingdisappeared, that “big black box” which needed to be maintained underspecial predefined conditions by a special air conditioning system con-structed ad hoc. With the development of distributed computer systems and of the per-sonal computer, the market for conditioners for DPC dropped vertically.We had already prepared for this situation: already towards the end of1988 we had started pushing more for the refrigeration for civil air condi-tioning which, in any case, already represented an important part of ourproduction (about 20% of our proceeds of sales).Towards the end of 1989 we acquired a company in Rome, the AMP, special-ized in the construction of big size water chillers and of an array of recip-rocating compressors with specific capacities from 200 to 500 kW.These two realities fused in November 1998 giving life to the RC Group.Between the end of the eighties and the beginning of the nineties we var-ied our mix of products a great deal: at the end of the last decade about80% of our production was aimed at data processing centres and about20% at refrigeration for air conditioning in the advanced tertiary, butalready in 1991-1992 the proportion had changed its course reaching aratio of 40% to 60%.This permitted us to maintain a constant growth and to have sufficientresources to transfer immediately to the emerging field of digital and cel-lular telephony, first, and of advanced computer systems today (technolo-gies connected to the transmission, elaboration and storage of data withInternet Protocol), all experience acquired in the systems for DPC.The results attained in these areas brought us to such an increase in pro-ceeds of sales that, even facing a continual increase in the field of refrig-eration for civil uses and for the tertiary, the mix returned to a net pre-dominance of products with a high technological content.At the present time, in the field of telecommunication, mobile phones andadvanced computer systems we cover a very interesting quota of themarket, both in Italy and worldwide where, if we exclude the United States,we are one of the two leading companies with worldwide coverage.In 1992, again with the aim of diversifying the production, a new evapora-tor was immediately studied and patented which incorporates a system ofaccumulation and expansion tank and filling called Idrocompl.

DUAL compressor at 10 cylinderscooling capacity 500kW

RC Group commercial department

Towards the end of 1989 we acquired acompany in Rome, the AMP, specializedin the construction of big size waterchillers and of an array of reciprocat-ing compressors with specific capaci-ties from 200 to 500kW.

Company presentation

Page 12: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

12 RC GROUP SpA • General Catalogue • 155.EN.0504

This component has become the starting point for the engineering of a newline of chillers with low capacity (7÷80kW) with innovative characteris-tics compared to the competition.Idrocompl boasts, in fact, a characteristic that makes it unique: it is abso-lutely resistant to the formation of ice on the inside, generated by wrongmanoeuvres or breakdown of the security devices.Since 2002 there have therefore been two productive poles, each with itsown philosophy at the product level:• AMP in Rome is the company that produces both the chillers with high

capacity (from 400 to 4000 kW) and a series of reciprocating compres-sors from 3 to 10 cylinders (presently the most powerful in the worldconstructed);

• RC Condizionatori in Pavia produces the middle range in the array of chill-ers (from 50 to 400 kW) and, in addition to that, is specialized in the partof air conditioning for telecommunication and for technological premisesof medium and large capacity and in the systems of air conditioning formobile communication;

• RC Condizionatori in Zeccone is specialized in small chillers (5÷270kW).Our productive growth over the nineties was therefore remarkable.

Consequently, the effort for organization to cover the various market ar-eas will also have been remarkable.

Yes, today our company is well represented throughout Italy with anetwork of Agents who are supported in turn by a network of technicalpost-sales service, even more vast and capillary. Abroad, instead, we workwith exclusive Distributors, companies which handle both the commerciali-zation of the product and the technical service.

Technical service is one of our favourite points: in our market of refer-ence, the technological field, machines must work 24 hours a day for 365days a year, so post-sales service is a key factor in the correct functioningof the system.

With the same philosophy we face also the civil and tertiary field, andso our authorized Service Centres are able to respond rapidly even in themost critical periods of the year.

How is this tissue of single realities managed? Centrally by the RC Group,or also by Rome?

At organizational level, the two divisions are maintained completelyindependent and are considered to be autonomous profit centres at pro-duction level, though they were fused in 1998 into a single legal entity,the RC Group. Research & Development, Commercial and Financial activi-ties are centralized. Centralized but not from a geographic standpoint,

Patented IDROCOMPL system

... our company is well representedthroughout Italy with a network ofAgents who are supported in turn by anetwork of technical post-sales service,even more vast and capillary.Abroad, instead, we work with exclu-sive Distributors, companies which han-dle both the commercialization of theproduct and the technical service.

Big Size Chiller assembly line

Company presentation

Page 13: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

13RC GROUP SpA • General Catalogue • 155.EN.0504

Soluzioni Affidabiliper

Applicazioni Critiche

since the technical, commercial and financial personnel is distributedamong the two structures and cooperate through an advanced commu-nication system, allowing sharing of projects, data, images and docu-ments in real time.

What are the pros and cons of this organization of sales based on Distribu-tors?

The Distributor is a choice we made at the beginning and one we be-lieve in and will carry on with. On the one hand it becomes challenging interms of management because there are three independent companiesworking with their own objectives and their own mode of being present onthe market. But, on the other hand, they guarantee a strong motivation forreaching volumes of sales increasingly more interesting.

In addition to that, a high and efficient exchange of information is real-ized without any type of filter: the more the Distributors are able to trans-fer their market problems to us, the more we are able to solve them cre-ating in this way objectives in common and a virtuous circle.

The mutual satisfaction of this system is confirmed by the fact that theturnover of our distributors is very low: 80% of those activated in 1983are still operating.

Also the turnover on the inside of our Group is low, perhaps thanks tothe fact the Company has always followed very precise procedures, bothat the commercial and industrial levels, with no abstruse or strange ma-noeuvres. There is stability in the organization and in the management whichmakes us dependable on the inside and towards the outside.

What’s the strategy behind your success story?Today the group is managed by a team composed of three persons: my

brother Fabrizio, our partner Sergio Gallina and me. All of us share thesame objectives and responsibilities. Our task is to further develop andinnovate some of the peculiarities behind RC success, one of which is to beforerunners in many organizational and technological aspects.

For example, in 1984 we were about fifty people, with a turnover thattouched 5 million Euro; in 2001, with 216 people, our turnover has ex-ceeded 80 million Euro. This result has been attained thanks to our choice,dating back to 1980, to maintain inside this structure a strong componentat an engineering, marketing and sales level, by outsourcing a part of ourproduction, that is using some very specialized outside entities to manu-facture components or pieces based on our design.

How are you organized from the technical point of view?We have two technical organizations: one is purely dedicated to the re-search and development of our products and/or systems, the other fol-lows the product, from its engineering for production to its perfecting

Performances test room up to 800 kW

Air Conditioners assembly line

... in 1984 we were about fifty people,with a turnover that touched 5 millionEuro; in 2001, with 216 people, ourturnover has exceeded 80 million Euro.

Company presentation

Page 14: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

14 RC GROUP SpA • General Catalogue • 155.EN.0504

according to the checks obtained from experience in the field.The technical organization of production is subdivided into 2 independ-

ent but inter-operative organizations, located in the production divisions ofPavia and Rome.

The management of all the technical issues of the group is the respon-sibility of Roberto Trecate, who has been working with us since 1968, whohas had a chance to see the product as a whole, from the phase of analysisof the needs of the client to the design, passing through the constructionand arriving at the installation and its maintenance in the field. A 360 de-gree view of the product, then, a very rare opportunity given the speciali-zation of the various fields. The research and development part is inte-grated with and collaborates daily with the technicians of the productionoffices in order to design new products and systems, without losing sightof their feasibility. At the moment when the prototype is accepted on thecommercial and performance level, the engineering is activated for theproduction and the successive commercial launch.

During my visit to the offices I noted a high level of computerization...In 1982 we had already developed software that permitted us to cre-

ate a virtual model of the product in order to be able to find out, with anacceptable margin of error, the performances even before having devel-oped the prototype. This software product was transformed into an elec-tronic catalogue that was distributed free of charge at our sales centresand among our clients in 1985.

It was perhaps one of the first electronic catalogues in our sector, andtoday it is fully integrated in our Enterprise Resource Planning software,since it has been turned into a Product Configurator for the manufacturingsystem. Today we are able to design the product and automatically gener-ate the software part that lets the distributor and the agent select it.

We care a lot about the computerized part which gives us daily sup-port that cannot be done without.

In 1983 we had already abolished drawing desks in favour of compu-ter-aided design (CAD), even though the operation really represented adisproportionate investment in our situation at that time.

Anticipating the times again in this aspect, we found ourselves readyfor the next steps with no effort. Today all products are developed with atridimensional CAD system, allowing an incredibly short Time to the Mar-ket vital to our success in the Information and Communication Technologybusiness. We have just implemented one of the most innovative ERP (sys-tems of resource planning for companies), for the real time managementof all corporate structures.

For years we have been using Internet to communicate with our salesnetwork and to give assistance by e-mail and we operate with a sophisti-cated system of Intranet that connects the 3 productive divisions in realtime at the level of voice, data and video.

The realization of Extranet is in progress which will permit our externalcollaborators to have direct access to all the company information regard-ing the products sold by them and to those currently in the catalogue.

Can you mention some other distinguishing organizational characteristics?In our company there are no managerial levels; it may be said that at

managerial level the company is “flat”.

RC WORLDproducts selection program

In 1982 we had already developed soft-ware that permitted us to create a vir-tual model of the product in order to beable to find out, with an acceptable mar-gin of error, the performances even be-fore having developed the prototype.

Medium Size Chiller assembly line

Company presentation

Page 15: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

15RC GROUP SpA • General Catalogue • 155.EN.0504

Soluzioni Affidabiliper

Applicazioni Critiche

Of course there are persons who, apart from their daily work, havealso management duties, but there are no managers operating on the basisof data or information provided by someone else. Everybody has a well-defined job and the offices are managed independently.

And at the product level?Our basic philosophy is that of not creating simply a product, but mak-

ing it unique through a mixture of innovations and “plus”.

We feel, for example, that we are a leader company regarding thenoise limiting of the water chillers and for years we have catalogued, as astandard product, a whole array of water chillers called ELN, with excep-tional intrinsic characteristics of low sound levels.

At the beginning of the seventies we were the first to propose an aircooled water chiller with an inbuilt free-cooling system.

The present MAXIMO is the result of this thirty year experience thathas reached its high point in the original control software making an en-ergy savings possible that is still unequalled.

Confirming our desire to maintain an actual leadership in this sector,all MAXIMO chillers are now available with the patented Free-CoolingOptimizer system, that will double the energy savings normally achievedby a standard free-cooling system.

Also regarding the materials we have been the first to introduce somechanges which by now have been adopted by everyone: for example, startingin the eighties we were the first company in our field to utilize aluminiumprofile to make the structural part of the product (I am talking about airconditioners and water chillers); in the same years we started substitutingthe copper capillaries, a fragile point in the cooling circuit, with flexible plas-

CAD system for tridimensional design

Liquid chillers • Noise pressure level at 10m far

dB(A) 75

70

65

60

55

50

45

40

STD

LNO

ELN

20 70 110 400 880 kW

Outdoor air temperature

EER

(W/W

)

100

10

1-5 0 5 10 15 20 25 30 35 40 °C

www.rcgroup.it

Our basic philosophy is that of not cre-ating simply a product, but making itunique through a mixture of innovationsand “plus”.

... all MAXIMO chillers are now availablewith the patented Free-Cooling Optimizersystem, that will double the energy sav-ings normally achieved by a standardfree-cooling system.

Company presentation

1 = Water chiller with Free-Cooling Optimizer • 2 = Air cooled water chiller

Page 16: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

16 RC GROUP SpA • General Catalogue • 155.EN.0504

tic pipes that were used in the air conditioning for automobiles.Then, still not satisfied with the performance of this product which had

a high porosity and therefore substantial losses over time, together with aMultinational operating in the field of plastic materials, we developed atype of material suitable for use in our field.

Now these flexible pipes are found in most good quality chillers, but forabout eight years we were the only company to have exclusivity. On thebasis of this experience we then proceeded to substitute with plastic ma-terial also the flow piping of compressors up to large dimensions.

Here the objective was not to eliminate breakdowns, but to limit thetransmission of the noise of the vibrations from the reciprocating com-pressor to the condensing system.

Today these applications are used by very many companies, but wewere the first to develop the idea and we promoted it.

In the field DPC we were the first to bring the compressors inside themachine in the environment, overcoming quite a lot of resistance from theclients, who were afraid of the noise and did not want to see repairmen intheir own data processing centres. We applied a whole series of expedi-ents so every problem has been overcome and now 99% of the units forthese centres have the compressor on the inside. We have always be-lieved in the need for innovation, not only on the product level but also onthe level of the component.

Another important aspect is that of regulation. Already by the end ofthe seventies we had electronic regulators with digital displays on ourmachines, which were substituted in 1984 with the first system of regula-tion using a microprocessor, completely developed by us from the hard-ware point of view as well as the software.

This experience has permitted us to develop a regulation which, dif-ferently from many others, really manages the unit. Indeed, all our con-trol systems with microprocessors come with the logic Proactive Con-trol System.

Thanks to this original system our control systems with microproc-essors are not only monitoring devices for what is happening, but theycontrol and regulate the complete functioning of the unit and the opera-tion of the security system, anticipating problems about to arise andguaranteeing in this way the continuous functioning of the unit even incritical situations.

The software used is innovative and patented, such as that for the heatpumps, called “Idea”, which makes it possible to obtain energy savings andefficiency decidedly superior to the average for the field.

Your company is one of the first of its field in Europe to obtain ISO 9000certification.

Actually we were the first company in our field in Europe to obtain ISO9000 certification; In Italy we were number 18, but those who preceded uswere of completely different types and dimensions.

Practically we already had an existing inside system of quality control;it meant simply to formalize it.

Today we have an office dedicated only to quality and we are repaidalso under this aspect: despite our being a somewhat small company, wehave been able, for example, to get contracts in the field of nuclear powerplants where the qualitative aspects, along with the security ones, are

MP2000microprocessor control system

Intelligent Defrosting system for Energy-saving Applications

... all our control systems with micro-processors come with the logicProactive Control System.Thanks to this original system our con-trol systems with microprocessors arenot only monitoring devices for what ishappening, but they control and regulatethe complete functioning of the unit andthe operation of the security system, an-ticipating problems about to arise andguaranteeing in this way the continuousfunctioning of the unit even in criticalsituations.

Company presentation

Page 17: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

17RC GROUP SpA • General Catalogue • 155.EN.0504

Soluzioni Affidabiliper

Applicazioni Critiche

SOLUTIONnew air conditioning system for information technology

ISO 9000 corporate certification

particularly strict. Thanks to the organizational structure that we havecreated over the years we were able, in fact, to produce a whole series ofdocumentation that would have normally cost us a remarkable effort.

Another concept you care a lot about is “transparency”; what exactly doyou mean with this term?

Our whole operation is based on the maximum openness, from ourway of providing service to our availability to collaborate with designers,from our relationships with Distributors to the possibility of stages whichwe offer to students.

Talking about technical service, we are more oriented to transferringour know-how to the various outside centres and to our Distributors,rather than to intervene directly. Even though our service centres andDistributors are completely independent companies, they are treated as ifthey were an integral part of our Company and we are not afraid to pro-vide 100% of the information. Our company Extranet is in the finishingstages and it will permit the Distributor and the service centre to accessthe company know-how using a series of passwords. They will be able toget directly all the information regarding the product that has been soldand therefore, its complete history, from production to life in the field. Weare creating these systems so that they will seem to be automatic routinerather than duties.

Our Extranet will permit us to give a response in real time to any typeof request in order to constantly improve our service to our customers.

And what about the future?Capitalizing on our ability to provide the market with COMPLETE SOLU-

TIONS to air conditioning requirements is of the essence.SOLUTIONS in which products are only a part to the way we want to

differentiate our offer from competitor’s ones. SOLUTIONS that will allowus to take advantage of our 40 years of experience in this business.

SOLUTION, RC Group’s new air conditioning system aimed to serve thenew Information and Communication infrastructures, is our first concreteresult in this new way to interact with the market.

With SOLUTION the already interesting advantages offered by everysingle product are enhanced by the synergies created by their joint use.

SOLUTION is a new way to develop a system, to market it and to use itscharacteristics to allow an immediate and substantial return of invest-ment to the end user.

In the future, the real challenge in our sector will focus on solutions,not just on products.

In the future, the real challenge in oursector will focus on solutions, not juston products.

Company presentation

Page 18: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

18 RC GROUP SpA • General Catalogue • 155.EN.0504

Albacom, Alcatel, Aletel, At&t, Belgacom, Blixer, Boujgue Telecom, British Telecom,Cegetel, Cerved Sinted, Colt, Comvik, EDS, France Telecom, Global Crossing, Hermes,Indosat, Iritel, Italtel, KPN, KPN Qwest, LDCom, Level 3, Mannesman, MCI Worldcom,Metroweb, Motorola, Netsiel, OTE, Pasifik Satelit Nusantara, PolishTelecom, Portugal Telecom, Post Danmark, Poste e Telegrafi, PtcTelecom, Retevision, Siemens, Stream, Swisscom, Telbank, Tele 2, Telecom Italia,Telecom South Africa, Telefonica, Telefonica Argentina, Telefony Brzeskie, TelefonyPolskie, Telenet, Telenokia, Telenor, Telia, Telkom, Telnet, Transpac, Unifon, Unisource.

Airtel, Alcatel, BlueTel, Boujgue Telecom, Cosmote, Ericsson, Ericsson Microwave,Libertel, Mannesman, Mercury Communications, Mobilcom, Motorola, Netcom GSM,Nokia, O-Tel-O, Omnitel, OTE, Orange, Proximus, PtcTelecom, Retevision Movil, Sie-mens, Sveriges Radio, Telecom Italia Mobile, Telefonica Moviles, Wind.

BANKSABN Bank, Alembank, AMRO Bank, Banca Agricola Milanese, Banca Arner, BancaCommerciale Italiana, Banca d’Italia, Banca del Lussemburgo, Banca di Roma, BancaNazionale del Lavoro, Banca Popolare di Milano, Banca Regionale Europea, BancaSella, Banca Toscana, Banco Ambrosiano Veneto, Bank of China Hua Qiao, BanqueBruxelles Lambert, Ca.Ri.Ge., Ca.Ri.P.Lo., Cassa di Risparmio di Firenze, Chase Man-hattan Bank, City Bank, Credit Agricole, Credit Suisse, Credito Italiano, Den NorskeBank, Deutsche Bank, Hypo Bank, Ing Bank, Istituto Bancario S. Paolo di Torino,Monte dei Paschi di Siena, Morgan Stanley, National WestBank, Paribas, Postbank,Rabo Bank, Swiss Bank Corporation, Union Bank of Switzerland.OFFICE BUILDINGSACI, Allianz Platz, Aok, Assicurazioni Generali, Bvk, Canal +, Club Med,Continentale, Eastern Pearl TV Tower, Fininvest, Gerling, IMI, Immo duTiomphe, INA, Kvb, Lloyd, Maa Assicurazioni, Pol-Kaufring (Canal +), RAI, RAS, RTLPlus, S. I. Les Eaux, Sat 1, ShangHai Zheng Xie, Sosintel, South Quay Plaza, StjarnTV, Sv Radio, SWIFT, Twice Trade Comm., Unibail, Videotime, Zbc.PUBLIC BODIESAem Milano, Acea Roma, Asl, Austrian Embassy - Bruxells, Avon & Sommerset PoliceH. Q., Borsa di Milano, British Government, Bundesbauddirektion Langer Eugen -Bonn, Bundeslander Versicherung - Wien, Camera dei Deputati, Edf - Nancy, EEC ArdenneAtrium & European Parliament - Bruxelles, Enea, Enel, Eni, Genio civile, Goteborg Posten,Insee - Lille, Israel Electrical Company, Istat, Supreme Court - Warsawa, Ministerodei Lavori Pubblici e del Tesoro, Ministry of Defence - Singapore, OMS - Geneva.

PUBLISHING INDUSTRIESDaily Express, Edipresse, Hurriyet Gazetecilik, Il Sole 24 Ore, Mondadori, PoligraficaS. Faustino, Rizzoli, Rotolito Lombarda.ELECTRONIC INDUSTRIESBarco, Beghelli, Bull, Cisco, Compaq, Digital, Ericsson, Fimi Phonola, Fujitsu,Getronics, Hewlett Packard, Honeywell, Ibm, Intel, Italtel, Magneti Marelli, Olivetti,Schneider Electric, Siemens, Telettra, Toshiba, Whirpool.CHEMICAL INDUSTRIESAgip, Du Pont, Enichem, Esso Italiana, Fisba Optik, Montell, Parek Chemical, Polfa,Procter & Gamble, Sika, Tioxide.MECHANICAL/STEEL INDUSTRIESAcciai Speciali Terni, Acciaierie Piombino, Alenia, Ansaldo, BMW, Bosch, CostruzioniAreonautiche Agusta, Electrocieplownia, Elsag Bailey, Fabrimetal, Ferrari, Fiat, Ford,Ilva, IVECO, Kroschu Kabelwerke, Laminazione sottile, Lucas Industries, Luxottica,

INFORMATION TECHNOLOGY

MOBILE COMMUNICATION

BANKING AND HI - TECH. OFFICES

INDUSTRIAL PROCESSES

References

Page 19: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

19RC GROUP SpA • General Catalogue • 155.EN.0504

Soluzioni Affidabiliper

Applicazioni Critiche

Magneti Marelli, Magona, Merloni, Nissan, Nuova Magrini Galileo, Ocean, Opel,Renault, Sandvik, Skf, Trumpf, Valeo, Volkswagen.PHARMACEUTICAL INDUSTRIESAntibioticos, Astra Pharmaceutical, Bayer, Boots, GlaxoWellcome, Hoechst, Hoffmann- La Roche, Innogenetics, Janssen, Pharmaceutica, Johnson & Johnson, Merk Sharp& Dome, Novartis, Parek Chemicals, Pharmacia & Upjon, Polfa, Schiapparelli.FOOD INDUSTRIESBarilla, CocaCola, Dolma, Gancia, Heineken, Hilcona, Lipton, Masterfoods, Misura,Nestlé, Rana, Plasmon, Stollwerk, Unilever.

Algiers Nat. Library, Autogrill, Biblioteca Ambrosiana - Milano, Biblioteca Sormani -Milano, Casino di Venezia, Cine Warner - San Sebastian, City Hall - Luzern, CityTheatre - Beirut, Escuela de Musica - Madrid, Fiera di Modena, Forte Hotels, Galleriad’Arte Moderna - Torino, Hotel Europa&Regina - Venezia, Mc. Donald’s, MesseDusseldorf, Pablo Picasso Museum - Munster, Palazzo Civran Badoer -Venezia, Palazzo Ducale - Genova, Sporting Centre - Stockholm, Teatro Carlo Felice- Genova, Tianjin Sports Centre , Wettingen Sport Centre - Zurich.UNIVERSITYKth - Stockholm, Politecnico di Milano, Sthlm Universitet - Stockholm, U.l.b.University- Bruxelles, Univerity College London, Universidade Augiro - Aveiro, UniversitàCattolica - Milano, Università di Bologna, Università di Cagliari, Università diMessina, Università di Milano, Università di Venezia, University of Bath, Universityof Budapest, University of Manchester, University of Walles.

Alby Center, An-Hyp, Astrup Fearnley - Oslo, Bennet, Bio Famila - Saren,C+A, Carrefour, Cash & Carry, Coin, Comm. Center Targowek - Warsawa, Conad,Coop, Domus, El Corte Ingles, Esselunga, Euromercato, Hipercor, Ica Maxi, Ikea, LaRinascente, Oviesse, Rathausgalerie - Wuppertal, Rubens - Berchem, Sc Uno, StovnerCentre - Oslo, UPIM, World Trade Centre - Cardiff.

Aereoporto Marco Polo - Venezia, Aeroporto di Fiumicino - Roma, Aeroporto di Peretola- Firenze, Aeroporto F. Baracca - Roma, Aeroporto Malpensa 2000 - Varese, Aeroportomilitare di Ghedi, Aeroporto militare di Villafranca, Athens Airport, Atm Milano, CivilAviation Authority - Southampton, Ferrovie dello Stato, Flughafen Frankfurt, JakartaAirport, Johannesburg Airport, S.n.c.b. - N.m.b.s. - Bruxelles, Shanxi Hong Kong, ShipolAmsterdam, Wan Hai Airport - Wan Hai, Wu Han Station - Wu Han, Zurich Airport.

A.He.Pa - Thessaloniki, BPA Vent Montor - Linkoping, Chirurgische Klinik - Mun-ster, Clinique des Grangettes - Geneva, H. Famille - Reet, Hospital Cheux de Fonds,Hospital Civil - Charleroi, Hospital Santana - Lisbon, Hospital of Chur, Hospital ofSchiers, Istituto Gaslini - Genova, Istituto Tumori di Milano, Kantonsspital - Olten,Klinikum - Wuppertal, Krankenhaus - Waldbrol, Meb Nuclearmedizin - Bonn,Middelheim - Antwerpen, Ospedale S. Carlo di Nancy - Roma, Ospedale CivicoChirurgia Toracica - Palermo, Ospedale B. S. Lorenzo - Firenze, Ospedale Civicodi Palermo, Ospedale Civile di Pescara, Ospedale Civile di Treviso, Ospedale diAlessandria, Ospedale di Bel luno, Ospedale di Bolzano, Ospedale diBrunico, Ospedale di Como, Ospedale di Sondrio, Ospedale Gall iera -Genova, Ospedale Geriatrico - Sospiro, Ospedale S. Andrea - Ravenna, OspedaleS. Eugenio - Roma, Ospedale Pertini - Roma, Policlinico - Milano, Policlinico S.Matteo - Pavia, Policlinico S. Orsola - Bologna, Radium Hospitalet - Oslo, RomeAmerican Hospital - Roma, Spedali Civili - Brescia, St. Elizabeth Hospital - Uccle,US Hospital - Linkoping.

INDUSTRIAL PROCESSES

LEISURE AND ENTERTAINMENT

SHOPPING CENTERS

TRANSPORT

HOSPITALS

References

Page 20: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

20 RC GROUP SpA • General Catalogue • 155.EN.0504

AIR CONDITIONING SYSTEM WITH UPFLOW AIR DELIVERY (OVER)It is the system traditionally used in the air conditioning field. The air distribution is from the top of the unit through a plenum deviceor through some ducts in case of false ceiling.The air flow in each area is predetermined during the design stage and it is not dependent on the actual state of the load to bedissipated.The system is normally applied in Comfort plants and in those plants having a defined low/medium room thermal loads density.

DIRECT EXPANSION UNITSAvailable up to 100 kW cooling capacity and over, these direct expansion air conditioning units are particularly suitable for low andmedium installations, where the compactness of the units and their simple installation are fundamental requirements. They are availableboth with remote air cooled condensers and in packaged version with built-in water cooled condenser. Equipped with Scroll typecompressors, characterized by high efficiency and low noise, RC GROUP direct expansion air conditioning units stand out for the buildingaccuracy, the high reliability and the extreme installation flexibility, thanks to a wide range of optional extras that have been conceivedto satisfy all demands.

CHILLED WATER UNITSSimilar to direct expansion units, the chilled water air conditioning units are suitable for medium - large installations matched todifferent kinds of liquid chillers.The range is very rich with a large number of optional extras suitable for every specific plant demand. The construction quality, thematerials used and the particular care at planning stage of RC GROUP chilled water units, guarantee noise levels among the lowest inthis product category.

PLAN

T TY

PEAir conditioners for hi-tech and comfort applications

Page 21: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

21RC GROUP SpA • General Catalogue • 155.EN.0504

CONSOLE.DX.A.O • R407C • 6 ÷ 16 kWAir conditioners for hi-tech and comfort applications (air cooled).

CONSOLE.DX.W.O • R407C • 7 ÷ 17 kWAir conditioners for hi-tech and comfort applications (water cooled).

CONSOLE.CW.O • 6 ÷ 23 kWAir conditioners for hi-tech and comfort applications (chilled water).

PEGASUS.DX.A.O • R407C • 6 ÷ 93 kWAir conditioners for hi-tech and comfort applications (air cooled).

PEGASUS.DX.W.O • R407C • 6 ÷ 102 kWAir conditioners for hi-tech and comfort applications (water cooled).

PEGASUS.CW.O • 4 ÷ 144 kWAir conditioners for hi-tech and comfort applications (chilled water).

COMPACT.CW.O • 40 ÷ 217 kWAir conditioners for hi-tech and comfort applications (chilled water).

22 OVER VERSION

24

26

28

30

32

34

Air conditioners for hi-techand comfort applications

INDE

X

Page 22: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

22 RC GROUP SpA • General Catalogue • 155.EN.0504

CONSOLE.DX.A.O - MODELCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

7.Z1 13.Z1 17.Z16,5 11,8 156,9 12,5 15,9

1300 2600 39001 1 1

1115 1515 1915465 465 465

1115 1115 1115130 200 26054 57 58,5

(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser air inlet at 35°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser air inlet at 35°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp

Air conditioners for hi-tech and comfort applications - OVERTE

CHNI

CAL D

ATA

CONSOLE.DX.A.ODirect expansion air conditioning unit with remote air cooled condenser, suitable for under window installations

hi-tech. facilities and offices.

Ductable air flow delivery from the top or direct delivery into the room through directional grilles.

AdaptiveRangeA wide range of models and optional conceived to satisfy specific installation needs in terms of

capacity, filtering and ventilation.

IDEN

TIFIC

ATIO

N

Page 23: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

23RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

R407C refrigerant charge •

Scroll type compressors •

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

Electric board separated from air flow •

Door lock main switch •

Cooling connections •

through Rotalock valves

RS485 serial line •

Remote air cooled condenser •

Electric heating •

Hot water heating •

Humidification and dehumidification •

Hot gas reheating system •

Air delivery plenum •

OPTI

ONAL

CONSOLE.DX.A.OR407C • 6 ÷ 16 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

DNA@RCThe large capacity precision

air conditioners technology

transferred to the units

dedicated to small areas.

QuickStartThe supply includes whatever is

needed for a correct unit working.

For the start-up the units only need

electrical, hydraulic and cooling

connections for a complete

installation in compliance with all the

current norms.

SpaceSaverInternal components lay out to

carry out all inspection and

maintenance operations from the

front of the unit, with no use of

side spaces.

HIGH

LIGHT

S

Page 24: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

24 RC GROUP SpA • General Catalogue • 155.EN.0504

CONSOLE.DX.W.O - MODELCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

7.Z1 13.Z1 17.Z16,8 12,4 15,97,2 13,2 16,9

1300 2600 39001 1 1

1115 1515 1915465 465 465

1115 1115 1115150 220 28054 57 58,5

(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser water inlet at 30°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser water inlet at 30°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp

TECH

NICA

L DAT

A

CONSOLE.DX.W.ODirect expansion air conditioning unit with built-in water cooled condenser, suitable for under window

installations hi-tech. facilities and offices.

Ductable air flow delivery from the top or direct delivery into the room through directional grilles.

WindowMateAir conditioners range designed for under window installation.

Air conditioners for hi-tech and comfort applications - OVERID

ENTI

FICAT

ION

Page 25: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

25RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

R407C refrigerant charge •

Scroll type compressors •

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

Electric board separated from air flow •

Door lock main switch •

RS485 serial line •

Water regulating valve •

Electric heating •

Hot water heating •

Humidification and dehumidification •

Hot gas reheating system •

Air delivery plenum •

OPTI

ONAL

CONSOLE.DX.W.OR407C • 7 ÷ 17 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

RCProactiveMP2000 control and monitoring

system technology owned by RC

PROACTIVE, conceived to grant

continuous operation even in

emergency situations.

FastHeatLow thermal inertia system for

electric heating, without

ionization

effect on treated air.

ServiceFastCompressors, electric board and

electronic regulation system

housed in a technical compartment

separated from the air flow to

allow standard maintenance with

the unit in operation.

HIGH

LIGHT

S

Page 26: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

26 RC GROUP SpA • General Catalogue • 155.EN.0504

CONSOLE.CW.O - MODELCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

7 14 215,6 11,2 177,6 15,2 23

1300 2600 39001115 1515 1915465 465 465

1115 1115 1115110 175 23052 54,5 56

(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47,5% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp

TECH

NICA

L DAT

A

CONSOLE.CW.OChilled water feeding air conditioning unit, suitable for under window installations hi-tech. facilities

and offices.

Ductable air flow delivery from the top or direct delivery into the room through directional grilles.

CoolingDensityPlusOptimization system of internal lay out to grant the best ratio between the unit footprint and the

cooling capacity.

Air conditioners for hi-tech and comfort applications - OVERID

ENTI

FICAT

ION

Page 27: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

27RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Centrifugal fans directly driven •

by electric motor

3 way proportional valve with •

emergency manual control

Microprocessor control system •

Electric board separated from air flow •

Door lock main switch •

RS485 serial line •

Electric heating •

Hot water heating •

Humidification and dehumidification •

Hot gas reheating system •

Air delivery plenum •

OPTI

ONAL

CONSOLE.CW.O5 ÷ 23 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ForcedDehumidificationSystem designed to keep the

room humidity without any air

flow restrictions prejudicial to

the cooling effectiveness.

EMCAll RC products are in compliance

with the norms about

electromagnetic compatibility.

SmartLinkSystem conceived for the

creation of a Local Area

Network (LAN), with unit

rotation and stand-by

management, without any

supplementary components.

HIGH

LIGHT

S

Page 28: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

28 RC GROUP SpA • General Catalogue • 155.EN.0504

PEGASUS.DX.A.O - MODELSizeCooling capacity (1) kWCooling capaciity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

PEGASUS.DX.A.O - MODELSizeCooling capacity (1) kWCooling capaciity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

5.Z1 7.Z1 10.Z1 10.Z1 15.Z1 10.Z1 18.Z1 15.Z1 15.Z1 15.Z1 20.Z1 18.Z1 24.Z2 30.Z2 20.Z1S0 S0 S0 S1 S1 S2 S2 S3S S3 S4 S4 S5 S5 S5 S65,9 7 8,8 10,9 14,6 11,3 17,1 16,3 15,4 16,8 20,7 18,7 24,4 28 22,66,3 7,4 9,3 11,6 15,5 12 18,1 17,4 16,4 17,9 22 19,8 25,9 29,7 23,6

1580 1580 1580 3150 3150 3640 3640 5000 5000 5570 5570 6000 6000 6000 82001 1 1 1 1 1 1 1 1 1 1 1 2 2 2

645 645 645 645 645 755 755 760 900 1105 1105 1125 1125 1125 1360410 410 410 645 645 645 645 760 860 645 645 860 860 860 860

1680 1680 1680 1930 1930 1930 1930 1950 1950 1930 1930 1950 1950 1950 1950145 150 155 200 205 210 230 285 285 245 255 320 370 375 38051,5 51,5 51,5 52 52 54 54 55 55 54,5 54,5 55,6 55,6 55,6 58

24.Z2 30.Z2 36.Z2 30.Z2 40.Z2 40.Z2 52.Z2 52.Z2 60.Z2 74.Z2 88.Z2 60.Z2 74.Z2 88.Z2S6 S6 S6 S7 S7 S8 S8 S9 S9 S9 S9 S10 S10 S1026 30,1 34,7 31,3 38,8 41,5 49,8 53,6 60 73,3 81,6 65,3 78,6 87,9

27,5 32 36,9 33,3 41,5 44,2 53,1 57,1 64 78 86,6 69,6 83,8 938200 8200 8200 10400 10400 13500 13500 17000 17000 17000 17000 22800 24500 24500

2 2 2 2 2 2 2 2 2 2 2 2 2 21360 1360 1360 1750 1750 2210 2210 2680 2680 2680 2680 3415 3415 3415860 860 860 860 860 860 860 860 860 860 860 900 900 900

1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950425 430 445 580 600 700 820 950 980 1000 1030 1290 1300 131558 58 58 59 59 60 60 61,5 62,5 62,5 62,5 63,5 65,5 65,5

(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser air inlet at 35°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser air inlet at 35°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models 5.Z.1 and 7.Z.1• 400.3.50+Mp for other models

TECH

NICA

L DAT

A

AdaptiveRangeA wide range of models and optional conceived to satisfy specific installation needs in terms of

capacity, filtering and ventilation.

PEGASUS.DX.A.ODirect expansion air conditioning units with remote air cooled condenser.

Units are suitable for hi-tech. facilities, offices and comfort applications.

Ductable air flow delivery from the top or direct delivery into the room through a plenum device.

Air conditioners for hi-tech and comfort applications - OVERID

ENTI

FICAT

ION

Page 29: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

29RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

R407C refrigerant charge •

Scroll type compressors •

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

Electric board in separated •

technical compartment

Door lock main switch •

Cooling connections •

through Rotalock valves

RS485 serial line •

Remote control board •

Remote air cooled condenser •

Electric heating •

Hot water heating •

Drive system fans •

Humidification and dehumidification •

Compressors capacity control •

Double cooling circuit unit •

Extra-Circuit system •

Hot gas reheating system •

Air delivery plenum •

High efficiency filters •

OPTI

ONAL

PEGASUS.DX.A.OR407C • 6 ÷ 110 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

PerformancePlusTandem SCROLL type

compressors to grant the

maximum energy efficiency in

any working condition.

MateIntegrated condensing control

system for stepless condenser fan

speed.

QuickStartThe supply includes whatever is

needed for a correct unit working. For

the start-up the units only need

electrical, hydraulic and cooling

connections for a complete installation

in compliance with all the current

norms.

HIGH

LIGHT

S

Page 30: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

30 RC GROUP SpA • General Catalogue • 155.EN.0504

PEGASUS.DX.W.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

PEGASUS.DX.W.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

5.Z1 7.Z1 10.Z1 10.Z1 15.Z1 10.Z1 18.Z1 15.Z1 15.Z1 15.Z1 20.Z1 18.Z1 24.Z2 30.Z2 20.Z1S0 S0 S0 S1 S1 S2 S2 S3S S3 S4 S4 S5 S5 S5 S66,2 7,3 9,1 11,5 15,7 11,9 18,7 17,8 16,7 17,9 22,2 20,8 26,8 30,2 24,56,6 7,8 9,7 12,2 16,7 12,7 19,9 19 17,8 19,1 23,7 22,1 28,5 32 26,1

1580 1580 1580 3150 3150 3640 3640 5000 5000 5570 5570 6000 6000 6000 82001 1 1 1 1 1 1 1 1 1 1 1 2 2 2

645 645 645 645 645 755 755 760 900 1105 1105 1125 1125 1125 1360410 410 410 645 645 645 645 760 860 645 645 860 860 860 8601680 1680 1680 1930 1930 1930 1930 1950 1950 1930 1930 1950 1950 1950 1950160 165 170 200 215 220 240 295 295 255 265 330 385 390 39051,5 51,5 51,5 52 52 54 54 55 55 54,5 54,5 55,6 55,6 55,6 58

24.Z2 30.Z2 36.Z2 30.Z2 40.Z2 40.Z2 52.Z2 52.Z2 60.Z2 74.Z2 88.Z2 60.Z2 74.Z2 88.Z2S6 S6 S6 S7 S7 S8 S8 S9 S9 S9 S9 S10 S10 S10

28,8 32,7 27,1 34,3 43,3 46,6 55,2 58,6 66,2 79,6 88 70,6 86,8 9630,6 34,7 39,4 36,4 46,1 50,2 59,2 62,6 70,6 84,9 94 75,5 92,9 1028200 8200 8200 10400 10400 13500 13500 17000 17000 17000 17000 22800 24500 24500

2 2 2 2 2 2 2 2 2 2 2 2 2 21360 1360 1360 1750 1750 2210 2210 2680 2680 2680 2680 3415 3415 3415860 860 860 860 860 860 860 860 860 860 860 900 900 9001950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950440 445 460 635 645 745 870 1000 1035 1055 1095 1350 1370 141058 58 58 59 59 60 60 61,5 62,5 62,5 62,5 63,5 65,5 65,5

(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser water inlet at 30°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser water inlet at 30°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models 5.Z.1 and 7.Z.1• 400.3.50+Mp for other models

TECH

NICA

L DAT

A

ServiceFastCompressors, electric board and electronic regulation system housed in a technical compartment

separated from the air flow to allow ordinary maintenance while unit in operation.

PEGASUS.DX.W.ODirect expansion air conditioning units with built-in water cooled condenser.

Units are suitable for hi-tech. facilities, offices and comfort applications.

Ductable air flow delivery from the top or direct delivery into the room through a plenum device.

Air conditioners for hi-tech and comfort applications - OVERID

ENTI

FICAT

ION

Page 31: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

31RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

R407C refrigerant charge •

Scroll type compressors •

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

Built-in water cooled condenser •

Electric board in separated •

technical compartment

Door lock main switch •

RS485 serial line •

Remote control board •

Electric heating •

Hot water heating •

Drive system fans •

Humidification and dehumidification •

Compressors capacity control •

Double cooling circuit unit •

Extra-Circuit system •

Hot gas reheating system •

Free-Cooling system •

Air delivery plenum •

High efficiency filters •

OPTI

ONAL

PEGASUS.DX.W.OR407C • 6 ÷ 125 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ForcedDehumidificationSystem designed to keep the

room humidity without any air

flow restrictions prejudicial to

the cooling effectiveness.

ExtraCircuitSystem designed for an optimal use

of the available cooling energy, or

as an integrated backup system.

Cool4FreeSystem conceived for indirect free

cooling, specially developed for

units equipped with built-in water

cooled condensers.

HIGH

LIGHT

S

Page 32: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

32 RC GROUP SpA • General Catalogue • 155.EN.0504

PEGASUS.CW.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

PEGASUS.CW.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

6 13 16 20 21 25 26S0 S1 S2 S3S S3 S4 S55,9 13,4 16,4 20,3 20,5 24,8 268 18,3 22,2 27,8 28,2 33,6 35,2

1580 3150 3640 5000 5100 5570 6000645 645 755 760 900 1105 1125410 645 645 760 860 645 860

1680 1930 1930 1950 1950 1930 1950130 160 180 235 235 200 27051 52 53 54 54 53,5 54,6

34 44 58 71 100 109S6 S7 S8 S9 S10 S10T

34,1 44,2 57,9 71,3 100 108,946,4 58,4 78,5 97 131,6 143,98200 10400 13500 17000 22800 264001360 1750 2210 2680 3415 3415860 860 860 860 900 900

1950 1950 1950 1950 1950 1950325 410 500 620 910 97054,7 58 60 62 63 70

(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for model S0 • 400.3.50+Mp for other models

TECH

NICA

L DAT

A

SpaceSaverInternal components lay-out to carry out all inspection and maintenance operations from the

front of the unit, with no use of side spaces.

PEGASUS.CW.OChilled water feeding air conditioning units suitable for hi-tech. facilities, offices and comfort applications.

Ductable air flow delivery from the top or direct delivery into the room through a plenum device.

Air conditioners for hi-tech and comfort applications - OVERID

ENTI

FICAT

ION

Page 33: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

33RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

3 way proportional valve with •

emergency manual control

Electric board in separated •

technical compartment

Door lock main switch •

RS485 serial line •

Remote control board •

Electric heating •

Hot water heating •

Drive system fans •

Humidification and dehumidification •

Extra-Circuit system •

Air delivery plenum •

High efficiency filters •

OPTI

ONAL

PEGASUS.CW.O5 ÷ 144 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

FastHeatLow thermal inertia

system for electric

heating, without

ionization effect on

treated air.

DirectControlHumidification system directly

controlled by the main

microprocessor according to

owned algorithms for the

proportional working.

SmartLinkSystem conceived for the

creation of a Local Area Network

(LAN), with unit rotation and

stand-by management, without

any supplementary components.

HIGH

LIGHT

S

Page 34: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

34 RC GROUP SpA • General Catalogue • 155.EN.0504

COMPACT.CW.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWCooling capacity (3) kWCooling capacity (4) kWAir flow m3/hDimensions Length mm

Depth mmHeight mmHeight (5) mm

Net weight kgNoise pressure level (6) dB(A)

42 71 92 110 116 138 166G0 G1 G2 G2S G3 G3S G4

41,8 71 91,8 -- 115,9 -- 166,456 95 119,9 -- 155,5 -- 217,4

26,2 44,6 57,4 71,4 73,2 88,9 104,339,5 67 86,7 104,7 109,1 122,2 157,18500 14600 18600 20000 24200 24200 340001.125 1.750 2.210 2.210 2.680 2.680 3.415900 900 900 900 900 900 900

1.950 1.950 1.950 1.950 1.950 1.950 1.9502.435 2.435 2.435 2.435 2.435 2.435 2.435290 445 545 570 680 700 98551 53 54 54,5 54 54 59

(1) Characteristics referred to air inlet at 24°C with 50% UR; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% UR; chilled water inlet at 7°C.(3) Characteristics referred to air inlet at 24°C with 50% UR; chilled water inlet at 10°C.(4) Characteristics referred to air inlet at 27°C with 47% UR; chilled water inlet at 10°C.(5) Unit height with base frame for air intake directly from the room(6) Noise pressure 1m far from the unit in free field conditions with ducted airflow delivery.POWER SUPPLY: 400.3.50+Mp

TECH

NICA

L DAT

A

CoolingDensityPlusOptimization system of internal lay-out to grant the best ratio between the unit footprint and the

cooling capacity.

COMPACT.CW.OChilled water units with upflow air delivery, suitable for hi-tech. facilities.

Air intake from the bottom of the unit and ductable air flow delivery from the top or direct delivery

into the room through a plenum device.

Air conditioners for hi-tech and comfort applications - OVERID

ENTI

FICAT

ION

Page 35: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

35RC GROUP SpA • General Catalogue • 155.EN.0504

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

VCoilCooling coils with

differentiated geometry for

the best use of exchange

surfaces.

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Centrifugal fans with belt drive system •

Microprocessor control system •

3 way proportional valve with •

emergency manual control

Electric board in separated •

technical compartment

Door lock main switch •

RS485 serial line •

Remote control board •

Electric heating •

Hot water heating •

Humidification and dehumidification •

Base frame from direct air •

intake from the room

Air intake/delivery plenum •

High efficiency filters •

OPTI

ONAL

COMPACT.CW.O40 ÷ 217 kW

DBeltDouble belt drive system with

wide regulation possibility

(starting from model G2).

ForcedDehumidificationSystem designed to keep the room

humidity without any air flow

restrictions prejudicial to the cooling

effectiveness.

HIGH

LIGHT

S

Page 36: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

36 RC GROUP SpA • General Catalogue • 155.EN.0504

AIR CONDITIONING SYSTEM WITH DOWNFLOW AIR DELIVERY THROUGH RAISED FLOOR (UNDER)The air distribution is from the bottom by means of the plenum between the building floor and the raised floor.This solution is usually applied in hi-tech. room a/c and it is most favourable when the thermal load is uniformly distributed in all areasof the room.

DIRECT EXPANSION UNITSAvailable up to 100 kW cooling capacity and over, these direct expansion air conditioning units are particularly suitable for low andmedium installations, where the compactness of the units and their simple installation are fundamental requirements. They are availableboth with remote air cooled condensers and in packaged version with built-in water cooled condenser. Equipped with Scroll typecompressors, characterized by high efficiency and low noise, RC GROUP direct expansion air conditioning units stand out for the buildingaccuracy, the high reliability and the extreme installation flexibility, thanks also to a wide range of optional extras that have beenconceived to satisfy all demands.

CHILLED WATER UNITSSimilar to direct expansion units, the chilled water air conditioning units are suitable for medium - large installations matched todifferent kinds of liquid chillers.The range is very rich with a large number of optional extras suitable for every specific plant demand. The construction quality, thematerials used and the particular care at planning stage of RC GROUP chilled water units, guarantee noise levels among the lowest inthis product category.

PLAN

T TY

PEClose control air conditioners - UNDER

Page 37: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

37RC GROUP SpA • General Catalogue • 155.EN.0504

CONSOLE.DX.A.U • R407C • 7 ÷ 17 kWClose control air conditioners (air cooled).

CONSOLE.DX.W.U • R407C • 7 ÷ 18 kWClose control air conditioners (water cooled).

CONSOLE.CW.U • 7 ÷ 29 kWClose control air conditioners (chilled water).

PEGASUS.DX.A.U • R407C • 6 ÷ 93 kWClose control air conditioners (air cooled).

PEGASUS.DX.W.U • R407C • 6 ÷ 102 kWClose control air conditioners (water cooled).

PEGASUS.CW.U • 6 ÷ 132 kWClose control air conditioners (chilled water).

COMPACT.CW.U • 40 ÷ 218 kWClose control air conditioners (chilled water).

38 UNDER VERSION

40

42

44

46

48

50

Close control air conditionersIN

DEX

Page 38: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

38 RC GROUP SpA • General Catalogue • 155.EN.0504

Close control air conditioners - UNDERTE

CHNI

CAL D

ATA CONSOLE.DX.A.U - MODEL

Cooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

7.Z1 13.Z1 17.Z16,8 12,3 15,67,3 13,1 16,7

1900 3800 57001 1 1

1115 1515 1915465 465 465

1040 1040 1040130 200 26056 59 61

(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser air inlet at 35°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser air inlet at 35°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp

CONSOLE.DX.A.UDirect expansion air conditioning units with remote air cooled condenser.

Units are suitable for under window installation hi-tech. facilities.

Downflow air delivery for air distribution through raised floor.

AdaptiveRangeA wide range of models and optional conceived to satisfy specific installation needs in terms of

capacity, filtering and ventilation.

IDEN

TIFIC

ATIO

N

Page 39: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

39RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

R407C refrigerant charge •

Scroll type compressors •

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

Technical compartment •

separated from the air flow

Door lock main switch •

Cooling connections •

through Rotalock valves

RS485 serial line •

Remote air cooled condenser •

Electric heating •

Hot water heating •

Humidification and dehumidification •

Hot gas reheating system •

Fresh air filter •

Antivibration rubber holder •

OPTI

ONAL

CONSOLE.DX.A.UR407C • 7 ÷ 17 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

RCProactiveMP2000 control and

monitoring system technology

owned by RC PROACTIVE,

conceived to grant continuous

operation even in emergency

situations.

ForcedDehumidificationSystem designed to keep the room

humidity without any air flow

restrictions prejudicial to the

cooling effectiveness.

HIGH

LIGHT

S

MateIntegrated condensing control

system for stepless condenser fan

speed.

Page 40: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

40 RC GROUP SpA • General Catalogue • 155.EN.0504

Close control air conditioners - UNDERTE

CHNI

CAL D

ATA CONSOLE.DX.W.U - MODEL

Cooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

7.Z1 13.Z1 17.Z17,1 13 16,57,6 13,8 17,6

1900 3800 57001 1 1

1115 1515 1915465 465 465

1040 1040 1040150 220 28056 59 61

(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser water inlet at 30°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser water inlet at 30°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp

CoolingDensityPlusOptimization system of internal lay-out to grant the best ratio between the unit footprint and the

cooling capacity.

CONSOLE.DX.W.UDirect expansion air conditioning unit with built-in water cooled condenser, suitable for hi-tech.

facilities applications with under window installation.

Downflow air delivery for air distribution through raised floor.

IDEN

TIFIC

ATIO

N

Page 41: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

41RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

R407C refrigerant charge •

Scroll type compressors •

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

Technical compartment •

separated from air flow

Door lock main switch •

RS485 serial line •

Water regulating valve •

Electric heating •

Hot water heating •

Humidification and dehumidification •

Hot gas reheating system •

Fresh air filter •

Antivibration rubber holder •

OPTI

ONAL

CONSOLE.DX.W.UR407C • 7 ÷ 18 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

SmartLinkSystem conceived for the

creation of a Local Area Network

(LAN), with unit rotation and

stand-by management, without

any supplementary components.

3SpeedDirect drive fans with 3

selectable speed motor.

ServiceFastCompressors, electric board

and electronic regulation

system housed in a technical

compartment separated from

the air flow to allow standard

maintenance with the unit in

operation.

HIGH

LIGHT

S

Page 42: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

42 RC GROUP SpA • General Catalogue • 155.EN.0504

Close control air conditioners - UNDERTE

CHNI

CAL D

ATA CONSOLE.CW.U - MODEL

Cooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

7 14 217 13,9 21,2

9,6 19,1 291900 3800 57001115 1515 1915465 465 465

1040 1040 1040110 175 23054 57 59

(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp

WindowMateAir conditioners range designed for under window installation.

CONSOLE.CW.UChilled water feeding unit suitable for hi-tech. facilities applications with under window installation.

Downflow air delivery for air distribution through raised floor.

IDEN

TIFIC

ATIO

N

Page 43: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

43RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Centrifugal fans directly driven •

by electric motor

3 way proportional valve with •

emergency manual control

Microprocessor control system •

Technical compartment •

separated from air flow

Door lock main switch •

RS485 serial line •

Electric heating •

Hot water heating •

Humidification and dehumidification •

Summer/Winter automatic •

working mode selection

Fresh air filter •

Antivibration rubber holder •

OPTI

ONAL

CONSOLE.CW.U 7 ÷ 29 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

FastHeatLow thermal inertia

system for electric

heating, without ionization

effect on treated air.

ProHumidImmersed electrodes humidifier

with proportional steam

production.

SpaceSaverComponents internal lay-out to

carry out all inspection and

maintenance operations from

the front of the unit, with no use

of side spaces.

HIGH

LIGHT

S

Page 44: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

44 RC GROUP SpA • General Catalogue • 155.EN.0504

TECH

NICA

L DAT

AClose control air conditioners - UNDER

PEGASUS.DX.A.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

PEGASUS.DX.A.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

(1) Characteristics referred to air inlet at 24°C with 50% rH; condenser air inlet at 35°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; condenser air inlet at 35°C.(3) Noise pressure 1m far from the unit in free field conditions with air delivery under the raised floor..POWER SUPPLY: 230.1.50 for models 5.Z.1 e 7.Z.1 • 400.3.50+Mp for other models

5.Z1 7.Z1 10.Z1 10.Z1 15.Z1 10.Z1 18.Z1 15.Z1 15.Z1 15.Z1 20.Z1 18.Z1 24.Z2 30.Z2 20.Z1S0 S0 S0 S1 S1 S2 S2 S3S S3 S4 S4 S5 S5 S5 S65,9 7 8,8 10,9 14,6 11,3 17,1 16,3 15,4 16,8 20,7 18,7 24,4 28 22,66,3 7,4 9,3 11,6 15,5 12 18,1 17,4 16,4 17,9 22 19,8 25,9 29,7 23,6

1580 1580 1580 3150 3150 3640 3640 5000 5000 5570 5570 6000 6000 6000 82001 1 1 1 1 1 1 1 1 1 1 1 2 2 2

645 645 645 645 645 755 755 760 900 1105 1105 1125 1125 1125 1360410 410 410 645 645 645 645 760 860 645 645 860 860 860 860

1680 1680 1680 1930 1930 1930 1930 1950 1950 1930 1930 1950 1950 1950 1950145 150 155 200 205 210 230 285 285 245 255 320 370 375 38051,5 51,5 51,5 48 48 49 49 51 51 49,5 49,5 51,5 51,5 51,5 53

24.Z2 30.Z2 36.Z2 30.Z2 40.Z2 40.Z2 52.Z2 52.Z2 60.Z2 74.Z2 88.Z2 60.Z2 74.Z2 88.Z2S6 S6 S6 S7 S7 S8 S8 S9 S9 S9 S9 S10 S10 S1026 30,1 34,7 31,3 38,8 41,5 49,8 53,6 60 73,3 81,6 65,3 78,6 87,9

27,5 32 36,9 33,3 41,5 44,2 53,1 57,1 64 78 86,6 69,6 83,8 938200 8200 8200 10400 10400 13500 13500 17000 17000 17000 17000 22800 24500 24500

2 2 2 2 2 2 2 2 2 2 2 2 2 21360 1360 1360 1750 1750 2210 2210 2680 2680 2680 2680 3415 3415 3415860 860 860 860 860 860 860 860 860 860 860 900 900 900

1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950425 430 445 580 600 700 820 950 980 1000 1030 1290 1300 131553 53 53 55 55 56 56 58 58 58 58 60 62 62

AdaptiveRangeA wide range of models and optional conceived to satisfy specific installation needs in terms of

capacity, filtering and ventilation.

PEGASUS.DX.A.UDirect expansion air conditioning units with and air cooled condenser suitable for hi-tech. facilities applications

and offices.

Downflow air delivery for air distribution through raised floor.

IDEN

TIFIC

ATIO

N

Page 45: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

45RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

R407C refrigerant charge •

Scroll type compressors •

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

Electric board in separated •

technical compartment

Door lock main switch •

Cooling connections through •

Rotalock valves

RS485 serial line •

Remote control board •

Remote air cooled condenser •

Electric heating •

Hot water heating •

Drive system fans •

Humidification and dehumidification •

Compressors capacity control •

Double cooling circuit unit •

Extra-Circuit system •

Hot gas reheating system •

Air intake/delivery plenum •

High efficiency filters •

OPTI

ONAL

PEGASUS.DX.A.UR407C • 6 ÷ 93 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ExtraCircuitSystem designed for an

optimal use of the

available cooling energy,

or as an integrated

backup system.

PerformancePlusTandem SCROLL type

compressors to grant the

maximum energy efficiency in

any working condition.

ForcedDehumidificationSystem designed to keep the

room humidity without any air

flow restrictions prejudicial to

the cooling effectiveness.

HIGH

LIGHT

S

Page 46: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

46 RC GROUP SpA • General Catalogue • 155.EN.0504

PEGASUS.DX.W.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

PEGASUS.DX.W.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

5.Z1 7.Z1 10.Z1 10.Z1 15.Z1 10.Z1 18.Z1 15.Z1 15.Z1 15.Z1 20.Z1 18.Z1 24.Z2 30.Z2 20.Z1S0 S0 S0 S1 S1 S2 S2 S3S S3 S4 S4 S5 S5 S5 S66,2 7,3 9,1 11,5 15,7 11,9 18,7 17,8 16,7 17,9 22,2 20,8 26,8 30,2 24,56,6 7,8 9,7 12,2 16,7 12,7 19,9 19 17,8 19,1 23,7 22,1 28,5 32 26,1

1580 1580 1580 3150 3150 3640 3640 5000 5000 5570 5570 6000 6000 6000 82001 1 1 1 1 1 1 1 1 1 1 1 2 2 2

645 645 645 645 645 755 755 760 900 1105 1105 1125 1125 1125 1360410 410 410 645 645 645 645 760 860 645 645 860 860 860 8601680 1680 1680 1930 1930 1930 1930 1950 1950 1930 1930 1950 1950 1950 1950160 165 170 200 215 220 240 295 295 255 265 330 385 390 39051,5 51,5 51,5 48 48 49 49 51 51 49,5 49,5 51,5 51,5 51,5 53

24.Z2 30.Z2 36.Z2 30.Z2 40.Z2 40.Z2 52.Z2 52.Z2 60.Z2 74.Z2 88.Z2 60.Z2 74.Z2 88.Z2S6 S6 S6 S7 S7 S8 S8 S9 S9 S9 S9 S10 S10 S10

28,8 32,7 37,1 34,3 43,3 46,6 55,2 58,6 66,2 79,6 88 70,6 86,8 9630,6 34,7 39,6 36,4 46,1 50,2 59,2 62,6 70,6 84,9 94 75,5 92,9 1028200 8200 8200 10400 10400 13500 13500 17000 17000 17000 17000 22800 24500 24500

2 2 2 2 2 2 2 2 2 2 2 2 2 21360 1360 1360 1750 1750 2210 2210 2680 2680 2680 2680 3415 3415 3415860 860 860 860 860 860 860 860 860 860 860 900 900 9001950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950440 445 460 635 645 745 870 1000 1035 1055 1095 1350 1370 141053 53 53 55 55 56 56 58 58 58 58 60 62 62

(1) Characteristics referred to air inlet at 24°C with 50% rH; condenser water inlet at 30°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; condenser water inlet at 30°C.(3) Noise pressure 1m far from the unit in free field conditions with air delivery under the raised floor..POWER SUPPLY: 230.1.50 for models 5.Z.1 e 7.Z.1 • 400.3.50+Mp for other models

TECH

NICA

L DAT

AClose control air conditioners - UNDER

SmartLinkSystem conceived for the creation of a Local Area Network (LAN), with unit rotation and stand-by

management, without any supplementary components.

PEGASUS.DX.W.UDirect expansion air conditioning units with downflow air delivery and built-in water cooled condenser, suitable

for hi-tech. facilities and offices.

Downflow air delivery for air distribution through raised floor.

IDEN

TIFIC

ATIO

N

Page 47: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

47RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

R407C refrigerant charge •

Scroll type compressors •

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

Built-in water cooled condenser •

Electric board in separated •

technical compartment

Door lock main switch •

RS485 serial line •

Remote control board •

Electric heating •

Hot water heating •

Drive system fans •

Humidification and dehumidification •

Compressors capacity control •

Double cooling circuit unit •

Extra-Circuit system •

Hot gas reheating system •

Free-Cooling system •

Air intake/delivery plenum •

High efficiency filters •

OPTI

ONAL

PEGASUS.DX.W.UR407C • 6 ÷ 102 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

NoiseControlNoise deading cups for a

further reduction of the

noise from the

compressors.

Cool4FreeSystem conceived for indirect free

cooling, specially developed for

units equipped with built-in water

cooled condensers.

QuickStartThe supply includes whatever is

needed for a correct unit

working. For the start-up the

units only need electrical,

hydraulic and cooling

connections for a complete

installation in compliance with

all the current norms.

HIGH

LIGHT

S

Page 48: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

48 RC GROUP SpA • General Catalogue • 155.EN.0504

PEGASUS.CW.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

PEGASUS.CW.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

6 13 16 20 21 25S0 S1 S2 S3S S3 S45,9 13,4 16,4 20,3 20,5 24,88 18,3 22,2 27,8 28,2 33,6

1580 3150 3640 5000 5100 5570645 645 755 760 900 1105410 645 645 760 860 645

1680 1930 1930 1950 1950 1930130 160 180 235 235 20051 45,7 46,8 48 48 47,5

26 34 44 58 71 100S5 S6 S7 S8 S9 S1026 34,1 44,2 57,9 71,3 100

35,2 46,4 58,4 78,5 97 131,66000 8200 10400 13500 17000 228001125 1360 1750 2210 2680 3415860 860 860 860 860 900

1950 1950 1950 1950 1950 1950270 325 410 500 620 91048 51 53 55,2 57 58,3

(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions with air delivery under the raised floor.POWER SUPPLY: 230.1.50 for model S0 • 400.3.50+Mp for other models

TECH

NICA

L DAT

AClose control air conditioners - UNDER

TopRateSystem designed to achieve the maximum energy saving in 24x365 working installations, thanks

to external indirect SCR free-cooling system which is integrated to the set-point compensation

software standard supplied on all CW units.

PEGASUS.CW.UChilled water feeding units with downflow air delivery, suitable for hi-tech. facilities applications and offices.

Downflow air delivery for air distribution through raised floor.

IDEN

TIFIC

ATIO

N

Page 49: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

49RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

3 way proportional valve with •

emergency manual control

Electric board in separated •

technical compartment

Door lock main switch •

RS485 serial line •

Remote control board •

Electric heating •

Hot water heating •

Drive system fans •

Humidification and dehumidification •

Extra-Circuit system •

Air intake/delivery plenum •

High efficiency filters •

OPTI

ONAL

PEGASUS.CW.U6 ÷ 132 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

YRFanPossibility to choose among

a wide range of both direct

and belt drive fan section.

ProHumidImmersed electrodes humidifier

with proportional

administration of steam

production.

RCProactiveMP2000 control and monitoring

system technology owned by RC

PROACTIVE, conceived to grant

continuous operation even in

emergency situations.

HIGH

LIGHT

S

Page 50: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

50 RC GROUP SpA • General Catalogue • 155.EN.0504

COMPACT.CW.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWCooling capacity (3) kWCooling capacity (4) kWAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (5) dB(A)

42 71 92 110 116 138 166G0 G1 G2 G2S G3 G3S G4

41,8 71 91,8 -- 115,9 -- 166,456 95 119,9 -- 155,5 -- 217,4

26,2 44,6 57,4 71,4 73,2 88,9 104,339,5 67 86,7 104,7 109,1 122,2 157,18500 14600 18600 20000 24200 24200 340001125 1750 2210 2210 2680 2680 3415900 900 900 900 900 900 1100

1950 1950 1950 1950 1950 1950 1950290 445 545 570 680 700 103551 53 54 54,5 54 54 59

(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 10°C.(4) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 10°C.(5) Noise pressure 1m far from the unit in free field conditions with air delivery under the raised floor.POWER SUPPLY: 400.3.50+Mp

TECH

NICA

L DAT

AClose control air conditioners - UNDER

CoolingDensityPlus200kW in less than 4m2 (DF=50 Kw/m2), the close control air conditioning unit with the highest

cooling density (kW per m2 of plan space) currently available in the market nowadays.

COMPACT.CW.UHigh capacity chilled water feeding units suitable for hi-tech. facilities applications.

Downflow air delivery for air distribution through raised floor.

IDEN

TIFIC

ATIO

N

Page 51: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

51RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Belt drive system centrifugal fans •

Microprocessor control system •

3 way proportional valve with •

emergency manual control

Electric board in separated •

technical compartment

Door lock main switch •

RS485 serial line •

Remote control board •

Electric heating •

Hot water heating •

Humidification and dehumidification •

Air intake/delivery plenum •

High efficiency air filters •

OPTI

ONAL

COMPACT.CW.U40 ÷ 218 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Easy@ServePossibility of air filters

removal from the front

without opening any access

panels.

EMCAll RC products are in

compliance with the norms

about electromagnetic

compatibility.

SpaceSaverInternal components lay-out

to carry out all inspection

and maintenance operations

from the front of the unit,

with no use of side spaces.

HIGH

LIGHT

S

Page 52: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

52 RC GROUP SpA • General Catalogue • 155.EN.0504

THE AIR-CONDITIONING SYSTEM WITH DISPLACEMENT AIR DELIVERYThe air-conditioning system with displacement air discharge is based on the principle that the air is distributed at a very lowspeed, while enabling a cooling effect by convection.This concept has been adjusted and applied by RC GROUP to the air-conditioning of telephone exchanges and rooms where theconcentration of electronic equipment is considerable, in order to maximise and optimise the results that can be obtained inthese specific ambients.

The modern Telecom devices have the aim of heat dissipation by air suction from the lower side close to the floor, and discharging itfrom the top. The air circulation in the equipment can be either natural, by convection, or in a forced way, through dedicated internalventilation systems.RC GROUP displacement system creates a cushion of cold air at the floor level, thanks to proprietary COLDLAYER technology, which isavailable for all the equipment installed in the room, and can reach also the equipment located in critical positions, thanks to patentedAIRRAIL® injectors.Every electronic equipment will “absorb” the amount of cold required to maintain a correct temperature level inside, through anatural convection effect.The greater the load inside the electronic equipment, the greater this effect.So, every electronic equipment uses only the amount required to dissipate its own thermal load, which is generated by maximising theresult and the energy efficiency of the system.This allows a better and more constant cooling of the electronic equipment ensuring the possibility to meet in real time any loadchanges, without any waste of energy.More than 2000 installations equipped with the RC GROUP displacement system have allowed our R&D division to develop, test andpatent the MISTRAL® control system.MISTRAL® ensures a perfect stratification of the temperatures in the room, as well as a perfect thermodynamic efficiency for theplant under any working conditions.MISTRAL®, thanks to the EFFICIENTFLOW technology, allows the system to adjust itself in real time to any load change, in terms ofquantity and distribution, while ensuring the best energy efficiency.

DIRECT EXPANSION UNITSAvailable up to 47 kW cooling capacity and over, these direct expansion air conditioning units are particularly suitable for low andmedium installations, where the compactness of the units and their simple installation are fundamental requirements.They are available both with remote air cooled condensers and in packaged version with built-in water cooled condenser.Equipped with Scroll type compressor, characterized by high efficiency and low noise, RC GROUP direct expansion air conditioning unitsstand out for the building accuracy, the high reliability and the extreme installation flexibility, thanks also to a wide range of optionalextras that have been conceived to satisfy all demands.

CHILLED WATER UNITSSimilar to direct expansion units, the HEAT HUNTER chilled water air conditioning units are suitable for variable water flow plantmatched to MAXIMO OPTIMIZER liquid chillers series.The range is very rich with a large number of optional extras suitable for every specific plant demand. The construction quality, thematerials used and the particular care at planning stage of RC GROUP chilled water units, guarantee noise levels among the lowest inthis product category.

PLAN

T TY

PEClose control air conditioners withDisplacement air delivery

Page 53: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

53RC GROUP SpA • General Catalogue • 155.EN.0504

54 HEAT HUNTER

56

58

Close control air conditionerswith Displacement air delivery

INDE

X HEAT HUNTER.DX • 6 ÷ 45 kWClose control air conditioners (air cooled).

HEAT HUNTER.DW • 6 ÷ 47 kWClose control air conditioners (water cooled).

HEAT HUNTER.CW • 10 ÷ 65 kWClose control air conditioners (chilled water).

Page 54: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

54 RC GROUP SpA • General Catalogue • 155.EN.0504

TECH

NICA

L DAT

A HEAT HUNTER.DX - MODELSizeCooling capacity (1) kWCooling capacity (2) kWCooling capacity (3) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (4) dB(A)

(1) Characteristics referred to air inlet at 24°C with 50% rH; condenser air inlet at 35°C.(2) Characteristics referred to air inlet at 27°C with 42% rH; condenser air inlet at 35°C.(3) Characteristics referred to air inlet at 30°C with 35% rH; condenser air inlet at 35°C.(3) Radiated noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp

007 009 010 013 015 016 020 023 026 030 037 045HH0 HH0 HH0 HH1 HH1 HH1 HH2 HH2 HH2 HH2 HH3 HH36,5 7,5 8,3 11,2 12,9 15,2 17,9 19,8 23,1 26,9 31,7 39,97 8,2 8,9 12,2 13,4 15,8 19,2 21,7 24,9 27,8 34,7 41,1

7,5 8,7 9,5 13 14,6 16,2 20,4 23,2 26,5 30,1 36,9 44,82200 2200 2200 3330 3330 3330 6660 6660 6660 6660 10000 10000

1 1 1 1 1 1 1 1 1 1 1 1785 785 785 1470 1470 1470 2005 2005 2005 2005 2540 2540600 600 600 600 600 600 600 600 600 600 600 600

1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980205 205 205 310 320 320 390 390 425 440 530 54045,7 45,7 45,6 48,4 49,5 49,8 51,9 52,2 53,5 56,1 56,6 57,3

ColdLayerRC proprietary technology to exploit at best the advantages of displacement air distribution,

tested in more than 2000 installations.

HEAT HUNTER.DXDirect expansion air conditioning units with remote air cooled condenser, suitable for hi-tech. facilities

applications and and telecom exchanges.

Displacement mode air delivery for air distribution directly into the room.

IDEN

TIFIC

ATIO

NClose control air conditioners withDisplacement air delivery

Page 55: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

55RC GROUP SpA • General Catalogue • 155.EN.0504

PatentCH

ARAC

TERI

STIC

SBase in aluminium profile frame painted •

with epoxy powders, galvanized steel

inner frame and galvanized steel sheet

panels externally coated with PVC film

R407C refrigerant charge •

Scroll type compressor •

Inverter controlled centrifugal fans •

directly driven by electric motor

Microprocessor control system •

Electric board in separated •

technical compartment

Door lock main switch •

Cooling connections through •

Rotalock valves

RS485 serial line •

Remote air cooled condenser •

Electric heater •

Humidification and dehumidification •

Direct Free-Cooling system •

Condensate discharge pump •

Compressor noise deading cup •

High efficiency filters •

Remote temperature sensor •

OPTI

ONAL

HEAT HUNTER.DXR407C • 6 ÷ 45 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

HoneyCombAir distribution grid

featuring an optimised

geometry, to increase the

ColdLayer effect.

Air-Rail®System patented by RC, consisting of a series of

aerodynamic inductors, to optimise the laminar air flow in

the actual conditions of installation and positioning.

FastHeatLow thermal inertia system

for electric heating,

without ionization

effect on treated air.

Page 56: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

56 RC GROUP SpA • General Catalogue • 155.EN.0504

TECH

NICA

L DAT

A HEAT HUNTER.DW - MODELSizeCooling capacity (1) kWCooling capacity (2) kWCooling capacity (3) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (4) dB(A)

(1) Characteristics referred to air inlet at 24°C with 50% rH; water to the condenser 29,5-35°C.(2) Characteristics referred to air inlet at 27°C with 42% rH; water to the condenser 29,5-35°C.(3) Characteristics referred to air inlet at 30°C with 35% rH; water to the condenser 29,5-35°C.(3) Radiated noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp

007 009 010 013 015 016 020 023 026 030 037 045HH0 HH0 HH0 HH1 HH1 HH1 HH2 HH2 HH2 HH2 HH3 HH36,7 8,2 9,3 11,9 14,1 16,6 19,7 21,3 25,4 29,4 35,9 44,37,4 8,5 9,6 12,9 14,6 17,2 21,1 23,3 26,4 30,4 38,8 45,87,9 9,4 10,5 13,8 15,8 17,8 22,8 24,9 29 31,4 41,3 47,3

2200 2200 2200 3330 3330 3330 6660 6660 6660 6660 10000 100001 1 1 1 1 1 1 1 1 1 1 1

785 785 785 1470 1470 1470 2005 2005 2005 2005 2540 2540600 600 600 600 600 600 600 600 600 600 600 600

1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980215 215 215 320 340 340 405 405 440 455 550 56545,7 45,7 45,6 48,4 49,5 49,8 51,9 52,2 53,5 56,1 56,6 57,3

IDEN

TIFIC

ATIO

NClose control air conditioners withDisplacement air delivery

DirectCoolProportional system for direct free-cooling, completely controlled by the microprocessor, for an

extreme reduction of compressor working hours and a high energy costs saving.

HEAT HUNTER.DWDirect expansion air conditioning units with built-in water cooled condenser, suitable for hi-tech. facilities

applications and and telecom exchanges.

Displacement mode air delivery for air distribution directly into the room.

Page 57: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

57RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSBase in aluminium profile frame painted •

with epoxy powders, galvanized steel

inner frame and galvanized steel sheet

panels externally coated with PVC film

R407C refrigerant charge •

Scroll type compressor •

Inverter controlled centrifugal fans •

directly driven by electric motor

Microprocessor control system •

Built-in water cooled condenser •

Electric board in separated •

technical compartment

Door lock main switch •

RS485 serial line •

Proportional electric heater •

Humidification and dehumidification •

Direct Free-Cooling system •

Condensate discharge pump •

Compressor noise deading cup •

High efficiency filters •

Remote temperature sensor •

OPTI

ONAL

HEAT HUNTER.DWR407C • 6 ÷ 47 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

Design@RCA new method to

“coat” the

product, which

becomes fit for

the most

demanding

architectural

requirements.

MP.COMThe new RC GROUP microprocessor control generation able to

communicate with the most advanced supervision systems.

MP.COM is equipped with a flash memory running a GSM modem, able

to send SMS alarm messages, and with a Data Logger working as a

“black box” for a correct analysis of failure causes.

1 2 3 4

M P . C O M g r a p h i c i n t e r f a c e

5 76

8

RC GROUP

Patent

Mistral®Thanks to the MISTRAL patented control logic, Heat Hunter can

maintain a perfect stratification of the room air, while ensuring

the best thermodynamic efficiency under any working

conditions and with any internal load.

Page 58: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

58 RC GROUP SpA • General Catalogue • 155.EN.0504

TECH

NICA

L DAT

A HEAT HUNTER.CW - MODELSizeCooling capacity (1) kWCooling capacity (2) kWCooling capacity (3) kWCooling capacity (4) kWCooling capacity (5) kWCooling capacity (6) kWAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (7) dB(A)

(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water temperature 7/12°C - 0% glycol solution.(2) Characteristics referred to air inlet at 27°C with 42% rH; chilled water temperature 7/12°C - 0% glycol solution.(3) Characteristics referred to air inlet at 30°C with 35% rH; chilled water temperature 7/12°C - 0% glycol solution.(4) Characteristics referred to air inlet at 24°C with 50% rH; chilled water temperature 9/14°C - 0% glycol solution.(5) Characteristics referred to air inlet at 27°C with 42% rH; chilled water temperature 9/14°C - 0% glycol solution.(6) Characteristics referred to air inlet at 30°C with 35% rH; chilled water temperature 9/14°C - 0% glycol solution.(7) Radiated noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp

014 021 025 044 066HH0 HH1 HH1 HH2 HH310,9 17,9 25,0 34,2 49,712,6 20,7 29,0 39,5 57,514,2 23,1 32,5 44,2 64,48,1 13,5 18,2 22,9 36,99,8 16,3 22,2 28,2 44,8

11,4 18,8 25,9 33,6 51,72200 3330 5500 6660 10000785 1470 1470 2005 2540600 600 600 600 600

1980 1980 1980 1980 1980165 270 290 355 43545,5 49,0 50,0 52,0 53,5

IDEN

TIFIC

ATIO

NClose control air conditioners withDisplacement air delivery

SynergyThe Heat Hunter system can be used to increase the capacity of existing plants, in perfect synergy

with traditional machines.

HEAT HUNTER.CWChilled water feeding air conditioning units, suitable for hi-tech. facilities applications and and telecom exchanges.

Displacement mode air delivery for air distribution directly into the room.

Page 59: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

59RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSBase in aluminium profile frame painted •

with epoxy powders, galvanized steel

inner frame and galvanized steel sheet

panels externally coated with PVC film

Inverter controlled centrifugal fans •

directly driven by electric motor

2 way proportional valve with •

emergency manual control

for variable water flow plant

Microprocessor control system •

Electric board in separated •

technical compartment

Door lock main switch •

RS485 serial line •

Remote air cooled condenser •

Proportional electric heater •

Humidification and dehumidification •

Direct Free-Cooling system •

Condensate discharge pump •

High efficiency filters •

Remote temperature sensor •

OPTI

ONAL

HEAT HUNTER.CW10 ÷ 65 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

EfficientFlowProprietary energy saving

system based on the fans

speed modulation according

to the real room load

conditions, the whole applied

to displacement technology.

SideBySideUnits are designed to be installed side by side to obtain a sort

of “Cold Wall” of any length.

SolutionHeat Hunter, in combination with our free-cooling Maximo

Optimizer chillers, forms the proprietary SOLUTION system, to

maximise the energy saving in the presence of variable flow-

rate technological plants.

Page 60: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

60 RC GROUP SpA • General Catalogue • 155.EN.0504

FLEXICLIM SYSTEM

Flexiclim, which is internationally patented and guaranteed by a huge number of important references both in Italy and abroad, isa flexible air distribution system and it is particularly suitable for those plants located in buildings where the inner air distributioncan be modified as the internal layout is revised, ie open space in offices or call centres, exposition rooms or museums areas fortemporary exhibitions. The air is treated by specific chilled water air conditioners with upflow or downflow air delivery. The

units are connected through flexible ducts to terminal distribution units with variable air flow. The great pro of this system is thepossibility to easily and rapidly move the terminal unit in order to meet the room changing needs (desks position, increase of desksnumber, expositive windows position, exposed works of art position). Installation rapidity and the possibility of primary air make thesystem very competitive in comparison with traditional primary air plants.

PLAN

T TY

PEFlexiclim System

Page 61: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

61RC GROUP SpA • General Catalogue • 155.EN.0504

INDE

X FLEXICLIM - FLEXIOVER.CW.O • 16 ÷ 48 kWChilled water air conditioning system for offices and hi-tech facilities.

FLEXICLIM - FLEXIUNDER.CW.U • 16 ÷ 48 kWChilled water air conditioning system for offices and hi-tech facilities.

62 FLEXICLIM SYSTEM

64

Flexiclim System

Page 62: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

62 RC GROUP SpA • General Catalogue • 155.EN.0504

PureAirSystem conceived to connect the local units to the terminal units in order to grant pure air in the

conditioned spaces, with no dependence from the maintenance status of the false ceiling.

FLEXIOVER.CW.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hAir delivery circular connections

For G1 terminals n. x ØFor G2 terminals n. x Ø

Dimensions Length mmDepth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

FLEXIBOX - MODELAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (4) dB(A)

(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions with ducted air distribution.(4) NR values (Noise rating) referred to room sound absorption 20m2 Sabine; directivity factor Q=2.POWER SUPPLY: 400.3.50+Mp

21 33 50Z1 Z2 Z315 23,8 36,1

20,1 32,1 48,43150 5200 7500

6 x 145 11 x 145 14 x 1455 x 195 8 x 195 12 x 1951245 1595 2500645 645 645

1930 1930 1930280 370 53040 42 45

G1 G2150 ÷ 500 200 ÷ 800

500 500500 500180 2507 8

29 ÷ 39 34 ÷ 44

TECH

NICA

L DAT

AFlexiclim System - OVER

IDEN

TIFIC

ATIO

N

Patent

FLEXICLIM®.CW.OFlexible chilled water feeding air conditioning system, suitable for hi-tech. facilities applications, offices and call

centres with false ceiling. Air intake/delivery from the top.

Page 63: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

63RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Sandwich panels •

Centrifugal fans directly driven •

by electric motor

Fans speed manual regulation •

Microprocessor control system •

Electric board in separated •

technical compartment

Door lock main switch •

Two configurations are available •

“M” configuration with single coil

“T” configuration with double coils

RS485 serial line •

Remote control board •

Electric heating •

Humidification and dehumidification •

Air delivery plenum •

Disposable air filters •

OPTI

ONAL

FLEXIOVER - FLEXICLIM.CW.O15 ÷ 48 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

RC GROUP

MP2000

FlexiBoxLocal terminal cassettes; the

passive ventilation system

totally eliminates the noise

problem and the standard

maintenance need.

Flexiclim - Flexiover System

HIGH

LIGHT

S

Page 64: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

64 RC GROUP SpA • General Catalogue • 155.EN.0504

FLEXIUNDER.CW.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hAir delivery circular connections

For G1 terminals n. x ØFor G2 terminals n. x Ø

Dimensions Length mmDepth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

FLEXIBOX - MODELAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (4) dB(A)

21 33 50Z1 Z2 Z315 23,8 36,1

20,1 32,1 48,43150 5200 7500

6 x 145 11 x 145 14 x 1455 x 195 8 x 195 12 x 1951245 1595 2500645 645 6451930 1930 1930280 370 53040 42 45

G1 G2150 ÷ 500 200 ÷ 800

500 500500 500180 2507 8

29 ÷ 39 34 ÷ 44

(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions with under floor air distribution.(4) NR values (Noise rating) referred to room sound absorption 20m2 Sabine; directivity factor Q=2.POWER SUPPLY: 400.3.50+Mp

TECH

NICA

L DAT

AFlexiclim System - UNDER

EasyFitThanks to EASY FIT system it is not necessary to create air delivery and intake areas in the raised

floor; the repositioning of FlexiBox cassettes due to new space needs doesn’t require either specialized

technicians intervention or plant or floor modifications.

IDEN

TIFIC

ATIO

N

Patent

FLEXICLIM®.CW.UFlexible chilled water feeding air conditioning system, suitable for hi-tech. facilities applications, offices and call

centres with raised floor. Air intake/delivery from the bottom.

Page 65: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

65RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Sandwich panels •

Centrifugal fans directly driven •

by electric motor

Fans speed manual regulation •

Microprocessor control system •

Electric board in separated •

technical compartment

Door lock main switch •

Two configurations are available •

“M” configuration with single coil

“T” configuration with double coils

RS485 serial line •

Remote control board •

Electric heating •

Humidification and dehumidification •

Disposable air filters •

OPTI

ONAL

FLEXIUNDER - FLEXICLIM.CW.U15 ÷ 48 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Flexiclim system is

internationally

patented and won the

reward for innovation

INTERCLIMA 1993.

RC GROUP

MP2000

Flexiclim - Flexiunder System

HIGH

LIGHT

S

Page 66: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

66 RC GROUP SpA • General Catalogue • 155.EN.0504

HEAT PUMP UNITSClose control air conditioning reliability applied to “Comfort” all year long. Available up to a capacity reaching 86 kW, heat pumpair conditioning units are particularly suitable for low and medium installations, where the compactness of the units and theirsimple installation are fundamental requirements. They are available both with remote air cooled condenser and in packagedversion with built-in water cooled condenser.Equipped with Scroll type compressors, characterized by high efficiency and low noise, RC GROUP air conditioning units stand out

for construction care, the high reliability and the extreme installation flexibility, thanks to a wide range of optional extras that havebeen conceived to satisfy all demands.

PLAN

T TY

PEHeat pump air conditioners

Page 67: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

67RC GROUP SpA • General Catalogue • 155.EN.0504

INDE

X PEGASUS.DX.A.P.O • R407C • 6 ÷ 86 kWHeat pump air conditioners (air cooled).

PEGASUS.DX.W.P.O • R407C • 6 ÷ 39 kWHeat pump air conditioners (water cooled).

68 HEAT PUMP VERSION

70

Heat pump air conditioners

Page 68: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

68 RC GROUP SpA • General Catalogue • 155.EN.0504

PEGASUS.DX.A.P.O - MODELSizeCooling capacity (1) kWHeating capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

PEGASUS.DX.A.P.O - MODELSizeCooling capacity (1) kWHeating capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

5.Z1 7.Z1 10.Z1 15.Z1 18.Z1 20.Z1 24.Z2S0 S0 S1 S1 S2 S4 S56,3 7,4 11,4 15,3 18 21,8 25,65,7 6,7 10,3 14,2 16,5 19,4 22,1

1580 1580 3150 3150 3640 5570 60001 1 1 1 1 1 2

645 645 645 645 755 1105 1125410 410 645 645 645 645 860

1680 1680 1930 1930 1930 1930 1950145 150 205 210 235 265 38051,5 51,5 52 52 54 54,5 55,6

30.Z2 36.Z2 40.Z2 52.Z2 60.Z2 74.Z2 88.Z2S5 S6 S7 S8 S9 S9 S9

29,2 35,9 40,2 52,5 63 76,2 8626,7 33 35,6 45,8 53,5 73,7 83,96000 8200 10400 13500 17000 17000 17000

2 2 2 2 2 2 21125 1360 1750 2210 2680 2680 2680860 860 860 860 860 860 860

1950 1950 1950 1950 1950 1950 1950385 460 615 840 1000 1020 105055,6 58 59 60 62,5 62,5 62,5

(1) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser air inlet at 35°C.(2) Characteristics referred to air inlet at 20°C, outdoor air at 7°C with 87% rH.(3) Noise pressure 1m far from the unit in free field conditions with ducted air distribution.POWER SUPPLY: 230.1.50 for models 5.Z.1 and 7.Z.1 • 400.3.50+Mp for other models

Heat pump air conditionersTE

CHNI

CAL D

ATA

DNA@RCThe large capacity precision air conditioning reliability transferred to “Comfort”

applications all year long.

PEGASUS.DX.A.P.OHeat pump air conditioning units with remote air cooled condenser suitable for comfort applications.

Ductable air flow delivery from the top or direct delivery into the room through a plenum device.

IDEN

TIFIC

ATIO

N

Page 69: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

69RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

R407C refrigerant charge •

Scroll type compressors •

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

Electric board in separated •

technical compartment

Door lock main switch •

Cooling connections through •

Rotalock valves

RS485 serial line •

Remote control board •

Remote air cooled condenser •

Electric or hot water heating •

Drive system fans •

Humidification •

Compressors capacity control •

Double cooling circuit unit •

Air delivery plenum •

Double expansion valve system •

High efficiency air filters •

OPTI

ONAL

PEGASUS.DX.A.P.OR407C • 6 ÷ 109 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

MateSystemAir cooled condensers specially

designed to work coupled with

heat pump units version with

direct control by the

microprocessor mounted on the

unit.

QuickStartThe supply includes whatever is

needed for a correct unit

working. For the start-up the

units only need electrical,

hydraulic and cooling

connections for a complete

installation in compliance with all

the current norms.

SpaceSaverInternal components lay-out to

carry out all inspection and

maintenance operations from the

front of the unit, with no use of

side spaces.

HIGH

LIGHT

S

Page 70: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

70 RC GROUP SpA • General Catalogue • 155.EN.0504

PEGASUS.DX.W.P.O - MODELSizeCooling capacity (1) kWHeating capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

5.Z1 7.Z1 10.Z1 15.Z1 18.Z1 20.Z1 24.Z2 30.Z2 36.Z2S0 S0 S1 S1 S2 S4 S5 S5 S66,6 7,98 12,2 16,7 19,9 23,6 28,5 32 396,2 7,5 10,5 15,7 18,7 22,2 26,3 30,6 36,8

1580 1580 3150 3150 3640 5570 6000 6000 82001 1 1 1 1 1 2 2 2

645 645 645 645 755 1105 1125 1125 1360410 410 645 645 645 645 860 860 860

1680 1680 1930 1930 1930 1930 1950 1950 1950160 165 205 220 250 275 395 400 47551,5 51,5 52 52 54 54,5 55,6 55,6 58

(1) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser water inlet at 30°C.(2) Characteristics referred to air inlet at 20°C entering water to gas/water heat exchanger at 15°C.(3) Noise pressure 1m far from the unit in free field conditions with ducted air distribution.POWER SUPPLY: 230.1.50 for models 5.Z.1 and 7.Z.1 • 400.3.50+Mp for other models

Heat pump air conditionersTE

CHNI

CAL D

ATA

AdaptiveRangeA wide range of models and optional conceived to satisfy specific installation needs in terms of

capacity, filtering and ventilation.

PEGASUS.DX.W.P.OHeat pump air conditioning units with built-in water cooled condenser suitable for comfort applications.

Ductable air flow delivery from the top or direct delivery into the room through a plenum device.

IDEN

TIFIC

ATIO

N

Page 71: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

71RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

R407C refrigerant charge •

Scroll type compressors •

Centrifugal fans directly driven •

by electric motor

Microprocessor control system •

Built-in water cooled condenser •

Electric board in separated •

technical compartment

Door lock main switch •

RS485 serial line •

Remote control board •

Electric or hot water heating •

Drive system fans •

Humidification •

Compressors capacity control •

Double cooling circuit unit •

Air delivery plenum •

High efficiency air filters •

OPTI

ONAL

PEGASUS.DX.W.P.OR407C • 6 ÷ 39 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

PerformancePlusTandem SCROLL type

compressors to grant

the maximum energy

efficiency in any working

condition.

SmartLinkSystem conceived for the

creation of a Local Area Network

(LAN), with unit rotation and

stand-by management, without

any supplementary components.

RCProactiveMP2000 control and

monitoring system

technology owned by RC

PROACTIVE, conceived to

grant continuous operation

even in emergency

situations.

HIGH

LIGHT

S

Page 72: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

72 RC GROUP SpA • General Catalogue• 155.EN.0504

AIR CONDITIONING SYSTEM WITH UPFLOW AIR DELIVERY (OVER)It is the system traditionally used in the air conditioning field. The air distribution is from the top of the unit through a plenum deviceor through supply ducts in the case of false ceiling.The air is injected into the room at a low temperature but at high speed in correspondence to the corridors between the differentracks rows. The cold air moves from the top to the bottom with a turbulent flow, mixing with the hot air outgoing from the racks.By this mixing effect the temperature of the air entering the racks is higher than the a/c unit leaving air temperature.

The air flow in each area is predetermined during the design stage and it is not dependent on the actual state of the load to be dissipated.The system can be applied in those plants having low/medium room thermal loads density, such as old systems, but it might be not suitablein the last IT and TLC plants, where the single thermal loads are very high.

FREE-COOLING PROPORTIONAL SYSTEMFor a further energy-saving, the RC GROUP conditioners are equipped with a proportional automatic free-cooling system in order toobtain free cooling when the indoor temperature is higher than outdoor one.Practically the fresh air is used as a refrigerant in order to cool the ambient, when the outside conditions allow it.The cooling system is totally proportional and allows three working modes:- total free-cooling: only fresh air is used to cool the ambient;- partial free-cooling: the fresh air is used for a pre-cooling and the compressor or the chilled water are used to balance the load;- mechanical cooling: the compressor or the chilled water are used to cool the ambient.

PLAN

T TY

PEAir conditioners for information technologyand communication

Page 73: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

73RC GROUP SpA • General Catalogue• 155.EN.0504

INDE

X MINIPAC.DX.A • R407C • 4 ÷ 19kWPackaged outdoor air conditioners for shelter

and telephone exchanges.

ENERTEL.DX.A.O • R407C • 5 ÷ 15 kWPackaged air conditioners for hi-tech. facilities

and telephone exchanges.

ENERGY.SPLIT.DX.A • R407C • 4 ÷ 15 kWSplit-system air conditioners for hi-tech. facilities

and telephone exchanges.

74 OVER VERSION

76

78

Air conditioners for informationtechnology and communication

Page 74: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

74 RC GROUP SpA • General Catalogue• 155.EN.0504

MINIPAC.DX.A - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

MINIPAC.DX.A - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

4.R1 5.R1 6.Z1 8.Z1 9.Z1S0 S1 S1 S1/S S1/S4,2 5,2 6 8,3 9,1

1100 1750 1750 2200 22001 1 1 1 1

660 831 831 902 902548 583 583 668 668

1303 1500 1500 1758 1758135 155 165 195 20054 52 57 57 62

11.Z1 13.Z1 16.Z1 20.Z1S2 S2 S3 S3

11,2 12,1 16,2 19,33200 3700 4300 5000

1 1 1 11000 1000 1000 1000700 700 700 700

2004 2004 2352 2352220 235 270 29058 58 58 64

(1) Characteristics referred to evaporator air inlet at 27°C with 42% rH; condenser air inlet at 35°C.(2) Noise pressure 1m far from the unit in free filed conditions.POWER SUPPLY: 230.1.50 from model 4.Z1 to model 9.Z1

400.3.50+N from model 11.Z1 to model 20.Z1

TECH

NICA

L DAT

A

Made2LastHousing designed to last in time and in bad weather.

MINIPAC.DX.A.OOutdoor air cooled packaged air conditioning unit suitable for telecom exchanges and shelters.

Horizontal air flow delivery for direct room distribution.

Air conditioners for information technologyand communication - OVER

IDEN

TIFIC

ATIO

N

Page 75: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

75RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSAluminium supporting housing •

Proportional free-cooling system •

R407C refrigerant charge •

Scroll or Rotative compressor •

Centrifugal fans •

Microprocessor control system •

Feeding voltage: •

Network + UPS at 230 Vac

Network + UPS at 48 Vdc

Built-in air cooled condenser •

Proportional condensing control •

RS485 serial line •

Remote control board •

Clogged filters alarm •

Room humidity sensor •

Electric heater •

LN function •

Mounting brackets kit •

OPTI

ONAL

MINIPAC.DX.AR407C • 4 ÷ 19 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

TwinPowerDouble feeding voltage

system, network + UPS,

conceived to grant

working continuity even

during black-out periods.

Easy@ServeAll regulation and control

components are easily

accessible.

RCProactiveMP2000 control and management

system, with RC PROACTIVE

proprietary technology, conceived to

grant continuity of work even in

emergency situations.

HIGH

LIGHT

S

Page 76: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

76 RC GROUP SpA • General Catalogue• 155.EN.0504

ENERTEL.DX.C.O - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

ENERTEL.DX.C.O - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

5.Z1 6.Z1 7.Z1S1 S1 S15,1 5,7 6,7

1700 1700 17001 1 1

650 650 650650 650 650

2000 2000 2000215 220 23560 60 60

8.Z1 10.Z1 11.Z1 13.Z1 15.Z1S2 S2 S2 S3 S39,2 10,4 11,5 13,3 14,6

3000 3000 3000 3400 34001 1 1 1 1

990 990 990 1190 1190650 650 650 650 650

2000 2000 2000 2000 2000320 330 340 390 40063 63 63 63 63

(1) Characteristics referred to evaporator air inlet at 27°C with 42% rH; condenser air inlet at 35°C.(2) Noise pressure 1m far from the unit in free filed conditions.POWER SUPPLY: 230.1.50 from model 5.Z1 to model 7.Z1

400.3.50+N from model 8.Z1 to model 15.Z1

TECH

NICA

L DAT

A

AdaptiveRangeA wide range of models and optional conceived to satisfy specific capacity, filtering, ventilation and plant needs.

ENERTEL.DX.A.OAir cooled packaged air conditioning unit suitable for telecom exchanges and hi-tech. facilities.

Ductable upflow air delivery or direct room distribution through a built-in plenum device.

Air conditioners for information technologyand communication - OVER

IDEN

TIFIC

ATIO

N

Page 77: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

77RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Free-cooling proportional system •

R407C refrigerant charge •

Scroll type compressor •

Centrifugal fans •

Microprocessor control system •

Feeding voltage: •

Network + UPS a 230 Vac

Network + UPS a 48 Vdc

Built-in air cooled condenser •

Proportional condensing control •

RS485 serial line •

Remote control board •

Clogged filters alarm •

Room humidity sensor •

Electric heater •

LN function •

Fresh air kit for air suction •

and outdoor air discharge

OPTI

ONAL

ENERTEL.DX.A.OR407C • 5 ÷ 15 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001certified.

EMCAll RC products are in

compliance with the norms

about electromagnetic

suitability.

QuickStartThe supply includes

whatever is needed for a

correct unit working.

For the start-up the units

only need electrical and

hydraulic connections for

a complete installation in

compliance with all the

current norms.

SmartLinkSystem conceived for the creation of a

Local Area Network (LAN), with unit

rotation and stand-by management,

without any supplementary components.

HIGH

LIGHT

S

Page 78: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

78 RC GROUP SpA • General Catalogue• 155.EN.0504

INDOOR EVAPORATING UNITENERGY.SPLIT.DX.A - MODELSizeCooling capacity (1) kWAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

OUTDOOR CONDENSING UNITENERGY.SPLIT.DX.A - MODELCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

4.R1 5.R1 6.Z1 7.Z1 8.Z1 10.Z1 13.Z1 15.Z1S0 S0 S0 S1 S1 S1 S2 S24 5,1 5,7 6,5 7,9 10,1 12,3 14,7

1400 1400 1400 2000 2000 2000 3900 39001132 1132 1132 1293 1293 1293 1293 1293834 834 834 980 980 980 1380 1380290 290 290 357 357 357 357 357442 45 45 80 80 80 103 10355 55 55 54 54 61 65 65

4.R1 5.R1 6.Z1 7.Z1 8.Z1 10.Z1 13.Z1 15.Z11 1 1 1 1 1 1 1

852 852 1048 1048 1048 1305 1305 1305460 460 460 460 460 580 580 580610 610 830 830 830 900 900 90055 65 70 70 75 95 98 10555 55 53 53 57 57 57 58

(1) Characteristics referred to evaporator air inlet at 27°C with 42% rH; condenser air inlet at 35°C.(2) Noise pressure 1m far from the unit in free filed conditions.POWER SUPPLY: Indoor evaporating unit : 230.1.50

Outdoor condensing unit: 230.1.50 from model 4.R1 to model 8.Z1 included400.3.50+N from model 10.Z1 to model 15.Z1

TECH

NICA

L DAT

A

SpaceSaverComponents inner arrangement to carry out all inspection and maintenance operations from the

front of the unit, with no use of side spaces.

ENERGY.SPLIT.DX.A.OSplit-system air conditioning units for telecom exchanges and hi-tech. facilities

Horizontal air flow delivery for direct room distribution through a built-in plenum device.

Air conditioners for information technologyand communication - OVER

IDEN

TIFIC

ATIO

N

Page 79: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

79RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Free-cooling proportional system •

R407C refrigerant charge •

Scroll type compressor •

Centrifugal fans •

Microprocessor control system •

Feeding voltage: •

Network + UPS at 230 Vac

Network + UPS at 48 Vdc

Built-in air cooled condenser •

Proportional condensing control •

RS485 serial line •

Clogged filters alarm •

Room humidity sensor •

Electric heater •

LN function •

Fresh air kit for air suction •

and outdoor air discharge

OPTI

ONAL

ENERGY.SPLIT.DX.AR407C • 4 ÷ 15 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001certified.

SleepWellProprietary Software for

unit working with the

lowest noise emission

during the night.

MateMATE integrated condensing control

system for a continuous speed

modulation of condensers fans.

DirectCoolProportional system for direct

free-cooling, completely

controlled by the

microprocessor, for an extreme

reduction of compressor

working hours and a high

energy costs saving.

HIGH

LIGHT

S

Page 80: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

80 RC GROUP SpA • General Catalogue• 155.EN.0504

AIR CONDITIONING SYSTEM WITH DISPLACEMENT MODE AIR DELIVERY (DISPLACEMENT)The basic concept of the air conditioning system with displacement air delivery is based on the natural convection principle, wherethe cold air is at the lower ambient zones, while the hot air is at the higher ones. This concept has been developed and applied byRC GROUP for the air conditioning in Telephone Exchangers and Hi-Tech. facilities.The modern Telecom devices have the aim of heat dissipation by air suction from the lower side close to the floor, for dischargefrom the top side. The air circulation inside the Telecom device can be in natural convenction mode or through internal fans.The RC GROUP free-cooling air conditioning system with displacement air delivery supplies the cold air directly into the room close

to the floor with low air speed and intakes the air from the top side of the conditioner where the air temperature is higher.Therefore, the Telecom devices (to be cooled) intakes the cold air from the bottom and discharges the hot air from the top.The system and the extremely low air speed, cause a high air stratification with 10°C temperature difference between the coldest andthe hottest zone.By hot air suction in the higher ambient zone, the air conditioner remarkably increases both the thermodynamic performance and theefficiency, with consequent working conditions and energy consumption optimization.

CONVERSION OF DISPLACEMENT UNITS INTO DOWNFLOW AIR DELIVERY AIR CONDITIONING UNITS FOR AIR DISTRIBUTIONTHROUGH DOUBLE FLOOR (UNDER)“Kit under” optional allows the conversion of the Displacement units into Under air conditioning units.The air distribution is from the bottom by means of the plenum formed between the building floor and the raised floor. The air can be directlyinjected into the racks if these are opened at the bottom and properly sealed, in order to avoid any possible leakage in the environment.The cold air flows through each apparatus, cooling the electronic equipment.The air flow moves upwards, enters the bottom part of the apparatus and leaves from the top. The air conditioners is provided with anair inlet from the top, for air intake from the warmest area in the room improving the plant energy performances. The system preventsa strong mixture of the cold air injected into the room and the hot air coming from the racks, typical of upflow air conditioners. This solutionis most favourable when the thermal load is uniformly distributed in all areas of the room. If the load distribution is not homogeneous,the position of the grilles and of the air outlet nozzles will have to be suitable to the existing load needs.The air conditioning unit draws the air to be cooled at a temperature higher than the one measured around the equipment to be cooled,obtaining higher thermodynamic performances. The air can also be distributed through grilles on the raised floor, in front of the racksrows. In this case the cold air is injected into the room near the equipment to be cooled; the equipment can draw autonomously thenecessary cooling air.

FREE-COOLING PROPORTIONAL SYSTEMFor a further energy-saving, the RC GROUP conditioners are equipped with a proportional automatic free-cooling system in order toobtain free cooling when the indoor temperature is higher than outdoor one.Practically the fresh air is used as a refrigerant in order to cool the ambient, when the outside conditions allow it.- total free-cooling: only fresh air is used to cool the ambient;- partial free-cooling: the fresh air is used for a pre-cooling and the compressor or the chilled water are used to balance the load;- mechanical cooling: the compressor or the chilled water are used to cool the ambient.The outdoor air introduction into the room causes an increase of the inner pressure which must be avoided to grant a correct plant work.Therefore on ENERGY.SPLIT and PEGASUS units it is necessary to install an overpressure damper near the ceiling to allow the exceedinghot air discharge outdoor.On the contrary on packaged units it is not necessary to install the damper because the air is directly discharged by the unit.

PLAN

T TY

PEAir conditioners for information technologyand communication - DISPLACEMENT

Page 81: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

81RC GROUP SpA • General Catalogue• 155.EN.0504

INDE

X ENERTEL.DX.A.DL • R134a • 6 ÷ 15 kWPackaged air conditioning units for hi-tech. facilities and telecom

exchanges.

PEGASUS.DX.A.DL • R407C • 5 ÷ 25 kWAir conditioning units with remote air cooled condenser for hi-tech.

facilities and telecom exchanges.

PEGASUS.CW.DL • 9 ÷ 55 kWChilled water feeding air conditioning units for hi-tech. facilities and

telecom exchanges.

86 DISPLACEMENT VERSION

88

90

Air conditioning units for informationtechnology and communication

Page 82: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

82 RC GROUP SpA • General Catalogue• 155.EN.0504

ENERTEL.DX.C.DL - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

ENERTEL.DX.C.DL - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

6.Z1 7.Z1 8.Z1S1 S1 S16,6 7,3 7,8

1850 1850 18501 1 1

750 750 750625 625 6252250 2250 2250215 230 24057 57 57

9.Z1 10.Z1 13.Z1 15.Z1S2 S2 S3 S39,9 10,9 14,6 15,5

2400 2400 3800 38001 1 1 1

950 950 1200 1200625 625 625 6252250 2250 2250 2250320 320 380 39055 55 61 61

(1) Performance referred to room conditions at 1m from floor at 24°C with 50% rH, deriving from the air conditioner air temperature inlet at 30°C with 35% rH;condenser air inlet at 35°C.

(2) Noise pressure 1m far from the unit in free filed conditions.POWER SUPPLY: 230.1.50 from model 6.Z1 to model 8.Z1

400.3.50+N from model 9.Z1 to model 15.Z1

TECH

NICA

L DAT

A

DisplacementAir intake system at lowest speed to exploit the displacement air conditioning technology.

ENERTEL.DX.A.DLAir cooled packaged air conditioning units suitable for hi-tech. facilities and telecom exchanges.

Air flow from the front or from the side through a grille for displacement air distribution.

Thanks to “kit under” optional it is possible to convert the unit into a downflow air conditioning unit (under).

Air conditioners for information technologyand communication - DISPLACEMENT

IDEN

TIFIC

ATIO

N

Page 83: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

83RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Free-cooling proportional system •

R134a refrigerant charge •

Scroll type compressor •

Centrifugal fans •

Microprocessor control system •

Feeding voltage: •

Network + UPS at 230 Vac

Network + UPS at 48 Vdc

Built-in air cooled condenser •

Proportional condensing control •

RS485 serial line •

Remote control board •

Clogged filters alarm •

Room humidity sensor •

Electric heater •

Fresh air kit for air suction •

and outdoor air discharge

Kit Under for unit conversion in •

downflow air conditioning unit

OPTI

ONAL

ENERTEL.DX.A.DLR134a • 6 ÷ 15 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001certified.

SpaceSaverDisplacement system

eliminates the need for

interspaces and ducts for the

correct air distribution inside

the rack.

DirectCoolProportional system for

direct free-cooling,

completely controlled by

the microprocessor, for an

extreme reduction of

compressor working

hours and a high energy

costs saving.

RCProactiveMP2000 control and management

system technology owned by RC

PROACTIVE, conceived to grant

continuity of work even in

emergency situations.

HIGH

LIGHT

S

Page 84: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

84 RC GROUP SpA • General Catalogue• 155.EN.0504

AIR CONDITIONERSPEGASUS.DX.A.DL - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

REMOTE AIR COOLED CONDENSERTEAM.MATE.DX.A - MODELAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

5.Z1 7.Z1 10.Z1 13.Z1 15.Z1 18.Z1 22.Z1 25.Z1S2 S2 S2 S4 S4 S4 S7/S S7/S5,9 7,6 10,6 13,5 16 18,4 23,1 26,3

1700 2150 2450 4000 4650 4650 6300 72501 1 1 1 1 1 1 1

755 755 755 1105 1105 1105 1720 1720645 645 645 645 645 645 645 6451930 1930 1930 1930 1930 1930 1930 1930220 225 235 260 265 270 375 38553 55 57 57 59 59 59 61

M.10 M.10 M.18 M.18 M.18 M.22 M.31 M.313400 3400 4400 4400 4400 5600 10100 10100850 850 850 850 850 1150 1350 150482 482 482 482 482 482 620 620726 726 726 726 726 726 1026 102631 31 37 37 37 47 95 95

29,3 29,3 31,3 31,3 31,3 30,3 39,3 39,3

(1) Performance referred to room conditions at 1m from floor at 24°C with 50% rH, deriving from the air conditioner air temperature inlet at 30°C with 35% rH;condenser air inlet at 35°C.

(2) Noise pressure 1m far from the unit in free filed conditions.(3) Noise pressure 10m far from the unit in free filed conditions, condensing coils side.POWER SUPPLY: 230.1.50 from model 5.Z1 to model 8.Z1

400.3.50+N from model 10.Z1 to model 25.Z1

TECH

NICA

L DAT

A

SpaceSaverDisplacement system eliminates the need for interspaces and ducts for the correct air distribution inside the rack.

PEGASUS.DX.A.DLDirect expansion air conditioning units with remote air cooled condenser suitable for hi-tech. facilities and telecom

exchanges. Air flow from the front or from the side through a grille for displacement air distribution. Thanks to

“kit under” optional it is possible to convert the unit into a downflow air conditioning unit (under).

Air conditioners for information technologyand communication - DISPLACEMENT

IDEN

TIFIC

ATIO

N

Page 85: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

85RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Free-cooling proportional system •

R407C refrigerant charge •

Scroll type compressor •

Centrifugal fans •

Microprocessor control system •

Feeding voltage: •

Network + UPS at 230 Vac

Network + UPS at 48 Vdc

Remote air cooled condenser •

Proportional condensing control •

RS485 serial line •

Remote control board •

Clogged filters alarm •

Room humidity sensor •

Electric heater •

Fresh air kit for air suction •

and outdoor air discharge

Kit Under for unit conversion in •

downflow air conditioning unit

OPTI

ONAL

PEGASUS.DX.A.DLR134a • 5 ÷ 25 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001certified.

MateMATE Integrated condensing control

system for a continuous speed

modulation of condensers fans.

QuickStartThe supply includes whatever is needed

for a correct unit working.

For the start-up the units only need

electrical, hydraulic and cooling

connections for a complete installation in

compliance with all the current norms.

Easy@ServeAll regulation and control components are

easily accessible from the front of the unit.

HIGH

LIGHT

S

Page 86: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

86 RC GROUP SpA • General Catalogue• 155.EN.0504

PEGASUS.CW.DL - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

8 11 22 35 48S2/S S2 S4 S7/S S8/S11,4 15 28,8 45,7 61,58,3 11,2 21,3 33,6 45,3

1500 2450 4650 7250 9800755 755 1105 1720 2180645 645 645 645 6451930 1930 1930 1930 1930175 180 200 295 37048 54 56,5 58 59

(1) Performance referred to room conditions at 1m from floor at 24°C with 50% rH, deriving from the air conditioner air temperature inlet at 30°C with 35% rH; chilled water inlet at 7°C.(2) Performance referred to room conditions at 1m from floor at 24°C with 50% rH, deriving from the air conditioner air temperature inlet at 30°C with 35% rH; chilled water inlet at 10°C.(3) Noise pressure 1m far from the unit in free filed conditions.POWER SUPPLY:The units in only cooling version are directly supplied by the UPS system at 230 Vac or 48VdcFor the units in cooling + heating version it is necessary to connect also the 400.3.50+N network supply.

TECH

NICA

L DAT

A

PerformancePlusDisplacement air distribution system grants an optimal temperatures stratification in the room

assuring the maximum possible thermodynamic efficiency in every situation.

PEGASUS.CW.DLChilled water feeding air conditioning unit suitable for hi-tech. facilities or telecom exchanges.

Air flow from the front and from the side through a grille for displacement air distribution.

Thanks to “kit under” optional it is possible to convert the unit into a downflow air conditioning unit (under).

Air conditioners for information technologyand communication - DISPLACEMENT

IDEN

TIFIC

ATIO

N

Page 87: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

87RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Free-cooling proportional system •

3 way cooling valve with •

proportional action

Centrifugal fans •

Microprocessor control system •

Feeding voltage: •

Network + UPS at 230 Vac

Network + UPS at 48 Vdc

RS485 serial line •

Remote control board •

Clogged filters alarm •

Room humidity sensor •

Electric heater •

Fresh air kit for air suction •

and outdoor air discharge

Kit Under for unit conversion in •

downflow air conditioning unit

OPTI

ONAL

PEGASUS.CW.DL9 ÷ 55 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001certified.

SaveProprietary energy saving

system based on the fans

speed modulation according to

the real room load conditions,

the whole applied to

displacement technology.

TwinPowerDouble feeding voltage

system, network + UPS,

conceived to grant working

continuity even during

black-out periods.

EasyLinkAir kit for air suction and

outdoor air discharge

HIGH

LIGHT

S

Page 88: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

88 RC GROUP SpA • General Catalogue • 155.EN.0504

RC GROUP liquid chillers: wide range of units in terms of models, compressors, refrigerants.

AIR COOLED LIQUID CHILLERSThe chillers are available in the versions with Scroll, Reciprocating and Screw type compressors.All models show a high energy efficiency and can be customized thanks to a wide range of optional extras including heat exchangers

for total or partial condensing heat reclaim.They are available with axial or centrifugal fans to allow the installation inside buildings with ducted air intake or exhaust systems.The latest generation and highly reliable microprocessor control system is equipped with RC PROACTIVE proprietary system and it isdesigned to be connected to the main Building Management and Remote Monitoring systems available on the market.

ELN RANGE (EXTREMELY LOW NOISE)For over 20 years RC Group has offered a standard catalogued range of units designed specifically to provide the "lowest noiseemission" equipment on the market.The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and reducing theserviceability of the equipment but instead has concentrated on removing the sound emissions at "source".By careful selection of matched components and innovative design of the condensing coil surface and airflow distribution, the ELN rangehas evolved into one of the quietest and thermally efficient Packaged Chillers in today's market place.This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy noise reductionkits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike that of the materials of the"bolt-on" sound reduction kits that can decay over time.All RC Group chillers are available in the ELN range, including versions with axial or centrifugal fans.

PLAN

T TY

PEAir cooled liquid chillers

Page 89: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

89RC GROUP SpA • General Catalogue • 155.EN.0504

EASY.A.STD “R” • R407C • 5 ÷ 41 kWLiquid chillers with scroll compressor.

EASY.A.STD “U” • R407C • 48 ÷ 186 kWLiquid chillers with scroll compressors.

EASY.A.STD “W” • R407C • 208 ÷ 460 kWLiquid chillers with scroll compressors.

CILLI.IDROCOMPL.A.STD.Z1 • R407C • 6 ÷ 17 kWIdrocompl liquid chillers with scroll compressor.

CILLI.IDROCOMPL.A.STD.Z2 • R407C • 20 ÷ 51 kWIdrocompl liquid chillers with scroll compressors.

UNICO.SCROLL.A.STD “G” • R407C • 20 ÷ 115 kWLiquid chillers with scroll compressors.

UNICO.SCROLL.A.ELN “G” • R407C • 19 ÷ 110 kWExtremely low noise liquid chillers with scroll compressors.

UNICO.RECIP.A.STD “G” • R407C • 137 ÷ 392 kWLiquid chillers with reciprocating compressors.

UNICO.RECIP.A.ELN “G” • R407C • 133 ÷ 271 kWExtremely low noise liquid chillers with reciprocating compressors.

UNICO.RECIP.A.STD “U” • R407C • 457 ÷ 990 kWLiquid chillers with reciprocating compressors.

UNICO.RECIP.A.ELN “U” • R407C • 355 ÷ 785 kWExtremely low noise liquid chillers with reciprocating compressors.

UNICO.RECIP.A.STD “M” • R407C • 500 ÷ 1950 kWLiquid chillers with reciprocating compressors.

MODULO.RECIP.A.STD • R407C • 200 ÷ 480 kWModular liquid chillers with reciprocating compressor.

UNICO.SCREW.A.STD “G” • R407C • 226 ÷ 379 kWLiquid chillers with screw compressors.

UNICO.SCREW.A.ELN “G” • R407C • 236 ÷ 314 kWExtremely low noise liquid chillers with screw compressors.

UNICO.SCREW.A.STD “U” • R407C • 444 ÷ 1137 kWLiquid chillers with screw compressors.

UNICO.SCREW.A.ELN “U” • R407C • 347 ÷ 850 kWExtremely low noise liquid chillers with screw compressors.

UNICO.SCREW.A.STD “M” • R407C • 564 ÷ 2331 kWLiquid chillers with screw compressors.

CILLI.IDROCOMPL.C.STD.Z1 • R407C • 6 ÷ 16 kWIdrocompl liquid chillers with scroll compressor.

CILLI.IDROCOMPL.C.STD.Z2 • R407C • 21 ÷ 51 kWIdrocompl liquid chillers with scroll compressors.

UNICO.SCROLL.C.STD “G” • R407C • 20 ÷ 112 kWLiquid chillers with scroll compressors.

UNICO.SCROLL.C.ELN “G” • R407C • 18 ÷ 110 kWExtremely low noise liquid chillers with scroll compressors.

UNICO.RECIP.C.STD “G” • R407C • 130 ÷ 265 kWLiquid chillers with reciprocating compressors.

UNICO.RECIP.C.ELN “G” • R407C • 130 ÷ 200 kWExtremely low noise liquid chillers with reciprocating compressors.

Air cooledliquid chillers

90 AXIAL FANS

92

94

96

98

100

102

104

106

108

110

112

114

116

118

120

122

124

126 CENTRIFUGAL FANS

128

130

132

134

136

INDE

X

Page 90: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

90 RC GROUP SpA • General Catalogue • 155.EN.0504

EASY.A.STD “R” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

EASY.A.STD “R” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

M.5.Z1 M.6.Z1 M.8.Z1 M.9.Z1R1 R1 R1 R15,2 6,4 7,4 8,61 1 1 11 1 1 1

1048 1048 1048 1048460 460 460 460836 836 836 83680 80 82 8357 57 57 57

T.8.Z1 T.9.Z1 T.11.Z1 T.14.Z1 T.16.Z1 T.18.Z1 T.20.Z1 T.24.Z1 T.28.Z1 T.35.Z1 T.43.Z1R1 R1 R2 R2 R2 R2 R3 R3 R3 R4 R47,4 8,6 11 12,8 15,5 17,2 20 23,9 27,4 33,7 41,41 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1

1048 1048 1305 1305 1305 1305 1305 1305 1305 1805 1805460 460 580 580 580 580 580 580 580 580 580836 836 900 900 900 900 1.285 1.285 1.285 1.285 1.28582 83 105 108 115 120 170 185 205 280 29557 57 57 57 60 60 59 59 62 62 62

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

ServiceFastCompressors, electric board and electronic control system housed in a technical compartment

separated from the air flow to allow standard maintenance with the unit in operation.

EASY.A.STD “R”Packaged air cooled liquid chillers equipped with Scroll compressor and axial fans.

IDEN

TIFIC

ATIO

N

Page 91: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

91RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing in galvanized steel sheet •

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate evaporator •

Microprocessor control system •

Antifreeze system •

Water flow control •

Idronic group •

Modulating condensing control •

Remote control board •

RS485 serial line • OPTI

ONAL

EASY.A.STD “R”R407C • 5 ÷ 41 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

DNA@RCTechnology of liquid chillers for

large installations transferred

to units dedicated to small

areas.

IdronicPackWater pump and tank in a

single package installed under

the chiller; a complete plant

without any increase in overall

dimensions.

Made2LastHousing designed to last in time

and in any weather condition.

HIGH

LIGHT

S

Page 92: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

92 RC GROUP SpA • General Catalogue • 155.EN.0504

EASY.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

EASY.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

T.50.Z2 T.55.Z2 T.68.Z2 T.84.Z2U5 U5 U6 U6

47,8 55,9 67,5 83,82 2 2 21 1 1 1

2000 2000 2580 25801200 1200 1200 12001630 1630 1630 1630740 740 810 83561 61 62 62

T.100.Z2 T.125.Z2 T.150.Z3 T.188.Z3U7 U7 U8 U8

97,5 123 146,5 184,52 2 3 31 1 1 1

3020 3020 4120 41201200 1200 1800 18001950 1950 1950 19501060 1080 1620 166067 71 69 72

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

AdaptiveRangeA wide range of models and optional designed for advanced air conditioning systems in

small and medium areas.

EASY.A.STD “U”Air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.

IDEN

TIFIC

ATIO

N

Page 93: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

93RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing in galvanized steel sheet •

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate evaporator •

Microprocessor control system •

Antifreeze system •

Water flow control •

Modulating condensing control •

Step-step cooling capacity control •

Pump-Down stop •

Door lock main switch •

Idronic group •

Remote control board •

RS485 serial line •

Partial or total heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

EASY.A.STD “U”R407C • 48 ÷ 185 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

MP.COMThe new generation of RC

microprocessors with

AUTOADAPTIVE logic conceived to

self adapting in real time to the

effective working conditions

basing on punctual operating

parameters such as: water flow,

plant inertia, outdoor air

temperature and presence of

antifreeze solutions in the plant.

PerformancePlusUp to three SCROLL type compressors in parallel connection to grant

the maximum energy efficiency mainly in partial load operation, which

represent more than 70% of the yearlong working hours.

IdronicPackWater pump and tank in a single

package installed under the

chiller, a complete plant without

any increase in overall

dimensions.

HIGH

LIGHT

S

Page 94: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

94 RC GROUP SpA • General Catalogue • 155.EN.0504

EASY.A.STD “W” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

T.200.Z4 T.240.Z4 T.300.Z6 T.360.Z6 T.400.Z6 T..450.Z6W1 W1 W2 W2 W3 W3

208,7 247,7 312,3 370,8 410 4574 4 6 6 6 62 2 2 2 2 2

2606 2606 3756 3756 4840 48402320 2320 2320 2320 2320 23202490 2490 2490 2490 2490 24901820 2020 2670 2970 3050 315069 73 71 74 75 76

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

EASY.A.STD “W”Air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.

IDEN

TIFIC

ATIO

N

Made2LastHousing designed to last in time and in any weather condition: flexible capillary pipes to avoid problems deriving from

copper work hardening; antivibration holders under the compressors to reduce vibration transmission to the housing;

galvanized steel sheet parts; aluminium or stainless steel small parts.

Page 95: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

95RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing in epoxy painted •

galvanized steel sheet

Plate evaporator •

Microprocessor control system •

Water flow control •

Modulating condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Door lock main switch •

Idronic group •

RS485 serial line •

Partial or total heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

EASY.A.STD “W”R407C • 208 ÷ 450 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

QuickStartWhatever is needed for a correct operation is built-in.

Only electrical and water connections are needed at start-up for a

complete installation in full compliance with all the current norms.

MateIntegrated condensing control

system for a stepless speed

modulation of condensers

fans.

KeepCoolRC designs and dimensions its R407C chillers in such a

way as to ensure continuous operation also at extreme

outside temperatures, that, at present, are the norm also

in temperate zones.

Page 96: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

96 RC GROUP SpA • General Catalogue • 155.EN.0504

Patent

CILLI.IDROCOMPL.A.STD.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

CILLI.IDROCOMPL.A.STD.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

M.7.Z1 M.8.Z1 M.9.Z16,2 7 8,41 1 11 1 1

1242 1242 1242447 447 447844 844 844135 137 14550 50 50

T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z17 8,4 12,9 14,9 16,51 1 1 1 11 1 1 1 1

1242 1242 1342 1342 1342447 447 497 497 497844 844 969 969 969137 145 185 195 20550 50 54 54 54

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

Idrocompl®Patented system including evaporator, water tank and expansion tank in a single component.

CILLI.IDROCOMPL.A.STD.Z1Air cooled packaged liquid chillers equipped with Scroll compressor, axial fan and Idrocompl system.

IDEN

TIFIC

ATIO

N

Page 97: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

97RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing in galvanized steel sheet •

externally coated with PVC film

IDROCOMPL system •

Microprocessor control system •

Antifreeze system •

On/off condensing control •

Circulating pump •

Modulating condensing control •

Remote control board •

RS485 serial line card • OPTI

ONAL

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

9

8

7

6

55

13

12

11

10

2 31 2 4

1. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger

Idrocompl® System

NoFreezeAntifreeze system which totally

preserves from the risks

subsequent to water freezing

inside the evaporator.

CILLI.IDROCOMPL.A.STD.Z1R407C • 6 ÷ 17 kW

QuickStartWhatever is needed for a correct

operation is built-in.

Only electrical and water

connection are needed at start-up

for a complete installation in full

compliance with all the current

norms.

HIGH

LIGHT

S

Page 98: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

98 RC GROUP SpA • General Catalogue • 155.EN.0504

CILLI.IDROCOMPL.A.STD.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

CILLI.IDROCOMPL.A.STD.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

T.24.Z2 T.28.Z2 T.34.Z221,4 24,2 28,7

2 2 21 1 1

1300 1300 1300895 895 895

1645 1645 1645375 385 42561 61 61

T.38.Z2 T.42.Z2 T.50.Z2 T.58.Z232,9 38 44,9 51,5

2 2 2 21 1 1 1

2000 2000 2000 2000895 895 895 895

1645 1645 1645 1645485 620 650 65562 64 64 64

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

Made2LastHousing designed to last in time and in any weather condition: flexible capillary pipes to avoid

problems deriving from copper work hardening; antivibration holders under the

compressors to reduce vibration transmission to the housing; housing in anodized

aluminium; galvanized steel sheet parts; aluminium or stainless steel small parts.

IDEN

TIFIC

ATIO

N CILLI.IDROCOMPL.A.STD.Z2Air cooled packaged liquid chillers equipped with Scroll compressors, axial fans and Idrocompl system.

Page 99: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

99RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

IDROCOMPL system •

Microprocessor control system •

Antifreeze system •

On/off condensing control •

Circulating pump •

Modulating condensing control •

Remote control board •

RS485 serial line card •

Spring antivibration holders •

Main switch •

OPTI

ONAL

CILLI.IDROCOMPL.A.STD.Z2R407C • 20 ÷ 51 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CoolingDensityPlusOptimization of internal

layout to achieve the best

ratio between footprint and

cooling capacity.

ServiceFastCompressors, electric board and electronic control system housed in

a technical compartment separated from the air flow to allow

standard maintenance with the unit in operation.

ScrollThe state of the art technology

in the field of medium/small size

compressors.

HIGH

LIGHT

S

Page 100: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

100 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.SCROLL.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.SCROLL.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G0 G0 G2 G2 G2 G4

20,3 23,2 32,5 36,7 49,3 56,51 1 1 1 1 11 1 1 1 1 1

1150 1150 2000 2000 2000 2600895 895 1040 1040 1040 1200

1640 1640 1690 1690 1690 1690330 330 480 540 590 75062 62 62 64 64 64

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G2 G2 G2 G4 G4 G6 G6 G6

34,6 40,3 45,5 60,4 69 87,5 97,9 114,92 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2000 2000 2000 2600 2600 3600 3600 36001040 1040 1040 1200 1200 1290 1290 12901690 1690 1690 1690 1690 1690 1690 1690570 590 610 820 860 1180 1240 124064 64 64 64 65 65 65 66

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

AdaptiveRangeA wide range of versions, models, to meet the requirements of a wide type of applications in

air conditioning systems for comfort, high-tech. and industrial cooling processes in any

climatic area.

UNICO.SCROLL.A.STD “G”Air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.

Casing type: “G”.

IDEN

TIFIC

ATIO

N

Page 101: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

101RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate evaporator •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCROLL.A.STD “G”R407C • 20 ÷ 115 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ScrollThe state of the art

technology in the field of

medium/small size

compressors.

PumpStationA complete built-in pumping

station (without size

increase), equipped with

instruments and safety

devices totally integrated with

the unit control system in

order to emphasize the RC

PROACTIVE system; possibility

to integrate PumpStation with

water tank without any

increase in footprint.

QuickStartWhatever is needed for a correct

operation is built-in.

Only electrical and water

connections are needed at start-

up for a complete installation in

full compliance with all the

current norms.

HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Page 102: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

102 RC GROUP SpA • General Catalogue • 155.EN.0504

ELN Range (Extremely low noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise

emission" equipment on the market.

The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and

reducing the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".

This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove

heavy noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with

time, unlike that of the materials of the "bolt-on" sound reduction kits that can decay over time.

UNICO.SCROLL.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.SCROLL.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G2 G2 G2 G4 G4 G4

19,1 22 29,2 34,7 45,8 55,41 1 1 1 1 11 1 1 1 1 1

2000 2000 2000 2600 2600 26001040 1040 1040 1200 1200 12001690 1690 1690 1690 1690 1690460 460 500 680 770 79050 53 51 53 54 55

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G4 G4 G4 G4 G6 G7 G7 G7

32,6 38,2 44,4 54,9 63,3 80,8 88,8 110,12 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2600 2600 2600 2600 3600 3600 3600 36001200 1200 1200 1200 1290 1290 1290 12901690 1690 1690 1690 1690 2215 2215 2215720 750 750 820 1120 1230 1290 134053 51 55 55 53 56 56 57

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

UNICO.SCROLL.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with Scroll

compressors and axial fans. Casing type: “G”.

IDEN

TIFIC

ATIO

N

Page 103: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

103RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate evaporator •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCROLL.A.ELN “G”R407C • 19 ÷ 110 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

AntirumbleRigid base frame made of a

multiple layer structure with

high noise absorption

characteristics, to reduce the

noise emission from the bottom

of the unit.

ZytelThe special compressor

discharge piped made of

patented plastic material

avoid the vibrations

transmission from the

compressor to the

condensing coils reducing

the total noise emission

and avoiding the early

materials decay.

HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Page 104: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

104 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.RECIP.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.RECIP.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

142.F2 188.F2 220.F2 260.F2 300.F2G7 G7 G8 G8 G8

137,3 169,4 202 242,6 269,82 2 2 2 22 2 2 2 2

3600 3600 5170 5170 51701290 1290 1290 1290 12902115 2115 2155 2215 22151575 1730 2095 2435 245066 66 67 73 73

320.S2 350.F2 385.S2 440.S2G9 G9 G9 G9

303 325,5 356,1 392,62 2 2 22 2 2 2

5900 5900 5900 59001540 1540 1540 15402470 2470 2470 24704030 3330 4070 408074 74 74 74

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

UNICO.RECIP.A.STD “G”Air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.

Casing type: “G”.

IDEN

TIFIC

ATIO

N

Made2LastHousing designed to last in time and in any weather condition: flexible capillary pipes to avoid

problems deriving from copper work hardening; antivibration holders under the

compressors to reduce vibration transmission to the housing; housing in anodized

aluminium; galvanized steel sheet parts; aluminium or stainless steel small parts.

Page 105: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

105RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Part-Winding compressors •

starting system (S)

Step-step cooling capacity control •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.RECIP.A.STD “G”R407C • 137 ÷ 392 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ServiceFastCompressors, electric

board and electronic

control system housed in a

technical compartment

separated from the air

flow to allow standard

maintenance with the unit

in operation.

BufferTankWater tank to increase plant

inertia with an extreme reduction

of compressors start-up, harmful

for their reliability and

endurance.

HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Page 106: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

106 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.RECIP.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.RECIP.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

142.F2 188.F2 220.F2G8 G8 G8

133,5 163,6 187,82 2 22 2 2

5170 5170 51701290 1290 12902155 2155 21551915 2000 209054 54 57

260.F2 300.F2G9 G9

238,3 271,32 22 2

5900 59001540 15402470 24702670 267060 63

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

UNICO.RECIP.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating

compressors and axial fans. Casing type: “G”.

IDEN

TIFIC

ATIO

N

ELN Range (Extremely low noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise

emission" equipment on the market.

The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and

reducing the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".

This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove

heavy noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with

time, unlike that of the materials of the "bolt-on" sound reduction kits that can decay over time.

Page 107: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

107RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Part-Winding compressors •

starting system (S)

Step-step cooling capacity control •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Part-Winding compressors •

starting system (F)

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.RECIP.A.ELN “G”R407C • 133 ÷ 271 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CoolingDensityPlusOptimization of internal layout to achieve the best ratio between

footprint and cooling capacity.

RCProactiveMP99 microprocessor control

and monitoring system

technology owned by RC

PROACTIVE, designed to grant

continuous operation even in

emergency situations.

HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Page 108: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

108 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.RECIP.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.RECIP.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

495.S2 550.S2 600.S2 660.S2U10 U10 U11 U11

457,1 493,9 563,8 601,62 2 2 22 2 2 2

5500 5500 6490 64902130 2130 2130 21302430 2430 2430 24304450 4460 4960 514076 76 76 76

770.S2 880.S2 990.S2 1100.S2U12 U13 U14 U14

705,5 802,1 914,9 988,92 2 2 22 2 2 2

7480 8470 9460 94602130 2130 2130 21302430 2430 2430 24305870 6540 7140 715077 78 78 78

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

UNICO.RECIP.A.STD “U”Air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.

Casing type: “U”.

IDEN

TIFIC

ATIO

N

FreezeProtectionEvaporator with built-in antifreeze heater and high thickness insulation, combined with

proprietary software for the automatic start up of the pumping group with direct scanning

from the digital antifreeze sensor.

Page 109: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

109RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Part-Winding compressors •

starting system

Step-step cooling capacity control •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.RECIP.A.STD “U”R407C • 457 ÷ 990 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ServiceFastCompressors, electric

board and electronic

control system housed in

a technical compartment

separated from the air

flow to allow standard

maintenance with the unit

in operation.

MyNoiseSolutions range (STD-LNO) conceived to allow the selection directly

from the catalogue of the most suitable product for the specific

legislative or environmental demands regarding the noise emission

control.

HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Page 110: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

110 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.RECIP.A.ELN “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.RECIP.A.ELN “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

320.S2 350.F2 385.S2 440.S2 495.S2U10 U10 U10 U10 U11

307,9 333,7 356,3 392,9 456,22 2 2 2 22 2 2 2 2

5500 5500 5500 5500 64902130 2130 2130 2130 21302430 2430 2430 2430 24304300 3600 4340 4350 495063 63 63 63 63

550.S2 600.S2 660.S2 770.S2 880.S2U11 U12 U12 U13 U14

492,7 558,4 595 693,9 786,12 2 2 2 22 2 2 2 2

6490 7480 7480 8470 94602130 2130 2130 2130 21302430 2430 2430 2430 24304960 5670 5670 6370 702063 63 63 64 64

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

UNICO.RECIP.A.ELN “U”Air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating

compressors and axial fans. Casing type: “U”.

IDEN

TIFIC

ATIO

N

ELN Range (Extremely low noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise

emission" equipment on the market.

The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and

reducing the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".

This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove

heavy noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with

time, unlike that of the materials of the "bolt-on" sound reduction kits that can decay over time.

Page 111: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

111RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Part-Winding compressors •

starting system

Step-step cooling capacity control •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.RECIP.A.ELN “U”R407C • 355 ÷ 785 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Easy@ServeAll components are

accessible through handy

hinged panels equipped

with antiwind lock,

without removal of heavy

noise deading boxes.

AntirumbleRigid base frame made of a multiple

layer structure with high noise

absorption characteristics, to reduce

the noise emission from the bottom of

the unit.

It is an essential device in all those

installations where the units are

installed ”raised” from the floor

through distribution bars and/or

antivibration holders.

HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Page 112: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

112 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.RECIP.A.STD “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.RECIP.A.STD “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

550.S2 600.S2 660.S2 770.S2 880.S2 990.S2 1100.S2 1210.S3 1320.S3M16 M16 M16 M17 M17 M18 M18 M19 M20506,4 558,2 600,4 703,8 782,2 893,4 972,4 1092,7 1197,4

2 2 2 2 2 2 2 3 32 2 2 2 2 2 2 3 3

5000 5000 5000 6070 6070 7140 7140 8490 95602350 2350 2350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 2510 2510 25105110 5110 5110 5900 6060 6620 6620 8350 916084 84 84 84 84 84 85 85 85

1420.S3 1530.S3 1640.S3 1750.S4 1860.S4 1970.S4 2080.S4 2190.S4M20 M21 M21 M17+M17 M18+M17 M18+M17 M18+M18 M18+M18

1286,5 1393,5 1463,6 1564,4 1672,8 1733,6 1875,5 1944,93 3 3 4 4 4 4 43 3 3 4 4 4 4 4

9560 10630 10630 12190 13260 13260 14330 143302350 2350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 2510 25109420 9600 9600 11920 12580 12580 13240 1324085 85 85 86 86 86 86 86

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

UNICO.RECIP.A.STD “M”Air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.

Casing type: “M”. M+M model casing is separated into two different sections to allow easier transport

and handling.

IDEN

TIFIC

ATIO

N

MyNoiseSolutions range (STD-LNO) conceived to allow the selection directly from the catalogue of the

most suitable product for the specific legislative or environmental demands regarding the

noise emission control.

Page 113: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

113RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of epoxy painted •

galvanized steel sheet

Shell and tube evaporator •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Part-Winding compressors •

starting system

Step-step cooling capacity control •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.RECIP.A.STD “M”R407C • 500 ÷ 1950 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ServiceFastCompressors, electric board

and electronic control system

housed in a technical

compartment separated from

the air flow to allow standard

maintenance with the unit in

operation.

AdaptiveRangeA wide range of models and optional designed to meet

the requirements of a wide type of applications in large

air conditioning installations and industrial cooling

systems.

HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Page 114: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

114 RC GROUP SpA • General Catalogue • 155.EN.0504

CoolingDensityPlus480kW in 6,5 m2 (DF = 74 kW/m2), the chiller with the highest Cooling Density (kW per m2 of

space in plan) currently available in the market.

MODULO.RECIP.A.STD - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

MODULO.RECIP.A.STD - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

220.S1 330.S1208 297,11 11 1

2830 28302300 23002395 23952700 296077 78

440.S1 550.S1396,5 478,4

1 11 1

2830 28302300 23002395 23953130 330080 80

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

MODULO.RECIP.A.STDModular air cooled packaged liquid chillers equipped with reciprocating compressor and axial fans.

IDEN

TIFIC

ATIO

N

Page 115: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

115RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of epoxy painted •

galvanized steel sheet

Shell and tube evaporator •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Part-Winding compressors •

starting system

Step-step cooling capacity control •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MODULO.RECIP.A.STDR407C • 200 ÷ 480 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

PumpStationA complete built-in pumping

station (without size increase),

equipped with instruments and

safety devices totally

integrated with the unit control

system in order to emphasize

the RC PROACTIVE system.

TR88Supervision and remote control

system; up to 8 MODULO can be

supervised in installations with

constant and variable flow

rate.

SideBySideMODULO is designed to be installed side by side to obtain

very high cooling capacities in reduced areas (for instance:

2 MW in only 26 m2 footprint!)

HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Page 116: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

116 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.SCREW.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.SCREW.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

230.V1 280.V1 330.V1 370.V1G8 G9 G9 G9

226,7 274,1 337,1 372,31 1 1 11 1 1 1

5170 5900 5900 59001290 1540 1540 15402155 2470 2470 24702265 3155 3300 332071 72 72 72

200.V2 240.V2 280.V2 320.V2 380.V2G8 G8 G9 G9 G9

205 241,3 242,4 331,6 3792 2 2 2 22 2 2 2 2

5170 5170 5900 5900 59001290 1290 1540 1540 15402155 2155 2470 2470 24702300 2310 3145 3590 362572 72 73 73 73

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

UNICO.SCREW.A.STD “G”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.

Casing type: “G”.

IDEN

TIFIC

ATIO

N

ScrewHelical twin screw compressors with high efficiency, possibility of proportional or multistep

setting, designed for air cooled chillers (high condensing temperatures).

Page 117: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

117RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Oil cooling system •

Star/delta compressors starting system •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCREW.A.STD “G”R407C • 226 ÷ 379 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Easy@ServAll components are

accessible from the front

of the unit allowing the

check and set of all

systems with the unit in

working mode.

RCProactiveMP99 microprocessor control and

monitoring system technology owned

by RC PROACTIVE, designed to grant

continuity of work even in

emergency situations.

HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Page 118: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

118 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.SCREW.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.SCREW.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

230.V1 280.V1G9 G9236 280,71 11 1

5900 59001540 15402470 24703075 315560 60

200.V2 240.V2 280.V2 320.V2G8 G9 G9 G9

191,7 245,3 278,5 314,32 2 2 22 2 2 2

5170 5900 5900 59001290 1540 1540 15402155 2470 2470 24702300 3120 3145 359056 61 61 61

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N UNICO.SCREW.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with screw compressors

and axial fans. Casing type: “G”.

ELN Range (Extremely low noise)Over 20 years of experience in sound reduction techniques together with SCREW technology enable RC Group to grant

sound emission levels never achieved in chillers with such reduced dimensions.

The result as for all ELN range chillers is achieved by a specific design philosophy concentrated on removing the sound

emissions at "source", without using "bolt-on" acoustic kits that can result in detrimental product efficiency, maintenance

and durability.

Screw ELN range allows design compliance to meet specific legislative or environmental acoustic control measures.

Page 119: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

119RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Oil cooling system •

Star/delta compressors starting system •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCREW.A.ELN “G”R407C • 236 ÷ 314 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

AntirumbleRigid base frame made of a multiple

layer structure with high noise

absorption characteristics, to reduce

the noise emission from the bottom of

the unit.

It is an essential device in all those

installations where the units are

installed ”raised” from the floor

through distribution bars and/or

antivibration holders.

MateIntegrated condensing control

system for a stepless speed

modulation of condensers fans.

Version available with R134a refrigerant chargesee page 274

Page 120: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

120 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.SCREW.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.SCREW.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

420.V1 470.V1 500.V1 550.V1U10 U10 U10 U11

444,1 477,1 498,5 587,71 1 1 11 1 1 1

5500 5500 5500 64902130 2130 2130 21302430 2430 2430 24303800 4000 4100 450075 75 75 75

460.V2 560.V2 660.V2 740.V2 840.V2 940.V2 1000.V2 1100.V2U10 U11 U11 U12 U13 U13 U14 U14

468,6 567,6 655,7 733,3 855,7 941,2 1003,7 1137,82 2 2 2 2 2 2 22 2 2 2 2 2 2 2

5500 6490 6490 7480 8470 8470 9460 94602130 2130 2130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 2430 2430 24304200 4850 4900 5600 6500 6700 7350 737076 76 76 77 78 78 79 79

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

UNICO.SCREW.A.STD “U”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.

Casing type: “U”.

Made2LastHousing designed to last in time and in any weather condition: flexible capillary pipes to avoid

problems deriving from copper work hardening; antivibration holders under the

compressors to reduce vibration transmission to the housing; housing in anodized

aluminium; galvanized steel sheet parts; aluminium or stainless steel small parts.

IDEN

TIFIC

ATIO

N

Page 121: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

121RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Oil cooling system •

Star/delta compressors starting system •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCREW.A.STD “U”R407C • 444 ÷ 1137 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ScrewHelical twin screw compressors with high efficiency, possibility of

proportional or multistep setting, designed for air cooled chillers

(high condensing temperatures).

HIGH

LIGHT

S

MyNoiseSolutions range (STD-LNO) conceived to

allow the selection directly from the

catalogue of the most suitable product for

the specific legislative or environmental

demands regarding the noise emission

control.

Version available with R134a refrigerant chargesee page 274

Page 122: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

122 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.SCREW.A.ELN “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.SCREW.A.ELN “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

330.V1 370.V1 420.V1 470.V1 500.V1 550.V1U10 U10 U10 U11 U11 U12

347,1 376,9 426,8 480,1 501,9 585,11 1 1 1 1 11 1 1 1 1 1

5500 5500 5500 6490 6490 74802130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 24303560 3610 3900 4400 4480 500062 62 62 62 62 62

380.V2 460.V2 560.V2 660.V2 740.V2 840.V2U10 U11 U12 U12 U13 U14384 472 564,7 644,3 732,7 850,12 2 2 2 2 22 2 2 2 2 2

5500 6490 7480 7480 8470 94602130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 24303900 4600 5200 5270 6150 695063 63 63 64 64 64

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N UNICO.SCREW.A.ELN “U”Air cooled packaged liquid chillers in extremely low noise version equipped with screw compressors

and axial fans. Casing type: “U”.

ELN Range (Extremely low noise)Over 20 years of experience in sound reduction techniques together with SCREW technology enable RC Group to grant

sound emission levels never achieved in chillers with such reduced dimensions.

The result as for all ELN range chillers is achieved by a specific design philosophy concentrated on removing the sound

emissions at "source", without using "bolt-on" acoustic kits that can result in detrimental product efficiency, maintenance

and durability.

Screw ELN range allows design compliance to meet specific legislative or environmental acoustic control measures.

Page 123: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

123RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Oil cooling system •

Star/delta compressors starting system •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCREW.A.ELN “U”R407C • 347 ÷ 850 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Easy@ServAll components are accessible through handy hinged panels equipped

with antiwind lock, without removal of heavy noise deading boxes.

HIGH

LIGHT

S

PumpStationA complete built-in pumping station

(without size increase), equipped

with instruments and safety

devices totally integrated with the

unit control system in order to

emphasize the RC PROACTIVE

system; possibility to integrate

PumpStation with water tank

without any increase in footprint.

Version available with R134a refrigerant chargesee page 274

Page 124: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

124 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.SCREW.A.STD “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.SCREW.A.STD “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

560.V2 650.V2 740.V2 840.V2 940.V2 1000.V2 1100.V2M16 M16 M17 M18 M18 M19 M19564,5 649 738,9 867,4 951,4 1027 1165,5

2 2 2 2 2 2 22 2 2 2 2 2 2

5000 5000 6070 7140 7140 8210 82102350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 25104650 4700 5500 6500 6750 7450 750079 79 79 80 80 81 81

1260.V3 1410.V3 1500.V3 1650.V3 1780.V4 1880.V4 2000.V4 2200.V4M20 M21 M21 M22 M17+M18 M18+M18 M19+M19 M19+M19

1300,2 1405,2 1517,1 1715,8 1781 1868,2 2053,9 2331,13 3 3 3 4 4 4 43 3 3 3 4 4 4 4

9560 10630 10630 11700 13260 14330 16470 164702350 2350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 2510 25108950 9000 9770 10400 12670 13500 14500 1475084 84 84 84 85 85 85 85

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with axial fans

UNICO.SCREW.A.STD “M”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.

Casing type: “M”. M+M model casing is separated into two different sections to allow

easier transport and handling.

FreezeProtectionEvaporator with built-in antifreeze heater and high thickness insulation, combined with

proprietary software for the automatic start up of the pumping group with direct scanning

from the digital antifreeze sensor.

IDEN

TIFIC

ATIO

NTE

CHNI

CAL D

ATA

Page 125: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

125RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of epoxy painted •

galvanized steel sheet

Shell and tube evaporator •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Star/delta compressors starting system •

Step-step cooling capacity control •

Oil cooling system •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCREW.A.STD “M”R407C • 560 ÷ 2331 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CoolingDensityPlusOptimization of internal layout to achieve the best ratio between

footprint and cooling capacity.

HIGH

LIGHT

S

ScrewHelical twin screw compressors

with high efficiency, possibility of

proportional or multistep setting,

designed for air cooled chillers

(high condensing temperatures).

Version available with R134a refrigerant chargesee page 274

Page 126: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

126 RC GROUP SpA • General Catalogue • 155.EN.0504

CILLI.IDROCOMPL.C.STD.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

CILLI.IDROCOMPL.C.STD.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

M.7.Z1 M.8.Z1 M.9.Z16,1 6,9 8,21 1 11 1 1

1242 1242 1242447 447 447844 844 844140 140 15058 58 58

T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z16,9 8,2 12,6 14,4 15,91 1 1 1 11 1 1 1 1

1242 1242 1342 1342 1342447 447 497 497 497844 844 969 969 969142 150 185 200 24058 58 64 64 64

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”

Liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N CILLI.IDROCOMPL.C.STD.Z1Air cooled packaged liquid chillers equipped with Scroll compressor, centrifugal fan and Idrocompl

system.

ServiceFastCompressor, electric board and electronic control system housed in a technical compartment separated

from the air flow to allow standard maintenance with the unit in operation.

Page 127: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

127RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing in galvanized steel sheet •

externally coated with PVC film

IDROCOMPL system •

Microprocessor control system •

Antifreeze system •

On/off condensing control •

Circulating pump •

Modulating condensing control •

Remote control board •

RS485 serial line •

Spring antivibration holders •

Main switch •

OPTI

ONAL

CILLI.IDROCOMPL.C.STD.Z1R407C • 6 ÷ 16 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CentriCentrifugal fan version for indoor and/or ducted

installations.

HIGH

LIGHT

S

ScrollThe state of the art technology in

the field of medium/small size

compressors.

Pump&PressureBuilt-in circulating pump with

water pressure control,

controlled by the central

microprocessor system.

Page 128: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

128 RC GROUP SpA • General Catalogue • 155.EN.0504

Patent

CILLI.IDROCOMPL.C.STD.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

CILLI.IDROCOMPL.C.STD.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

T.24.Z2 T.28.Z2 T.34.Z221,4 24,2 28,7

2 2 21 1 1

1300 1300 1300895 895 8951645 1645 1645375 385 42566 66 66

T.38.Z2 T.42.Z2 T.50.Z2 T.58.Z232,9 38 44,9 51,5

2 2 2 21 1 1 1

2000 2000 2000 2000895 895 895 8951645 1645 1645 1645485 620 650 65568 69 69 69

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N CILLI.IDROCOMPL.C.STD.Z2Air cooled packaged liquid chillers equipped with Scroll compressors, centrifugal fan and Idrocompl

system.

IdrocomplPatented system including evaporator, water tank and expansion tank in a single component.

Page 129: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

129RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

IDROCOMPL system •

Microprocessor control system •

Antifreeze system •

On/off condensing control •

Circulating pump •

Modulating condensing control •

Remote control board •

RS485 serial line •

Spring antivibration holders •

Main switch •

OPTI

ONAL

CILLI.IDROCOMPL.C.STD.Z2R407C • 21÷ 51 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

NoFreezeAntifreeze system which totally

preserves from the risks

subsequent to water freezing

inside the evaporator.

HIGH

LIGHT

S

9

8

7

6

55

13

12

11

10

2 31 2 41. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger

Idrocompl® system

PerformancePlusSCROLL type compressors in parallel connection to grant the

maximum energy efficiency mainly in partial load operation, which

represent more than 70% of the yearlong working hours.

Page 130: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

130 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.SCROLL.C.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.SCROLL.C.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G1 G1 G1 G3 G3 G3

19,2 21,8 28,7 35,2 46,9 56,81 1 1 1 1 11 1 1 1 1 1

1150 1150 1150 2000 2000 2000895 895 895 1040 1040 1040

1960 1960 1960 2010 2010 2010390 390 435 670 740 76059 59 66 60 68 68

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G3 G3 G3 G3 G5 G7 G7 G7

32,5 38 43,1 56,3 69 83,8 92,8 1122 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2000 2000 2000 2000 2600 3600 3600 36001040 1040 1040 1040 1200 1290 1290 12902010 2010 2010 2010 2240 2010 2010 2010690 710 720 790 1060 1450 1510 154059 60 64 68 70 69 69 69

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

UNICO.SCROLL.C.STD “G”Air cooled packaged liquid chillers equipped with Scroll compressors and centrifugal fans.

Casing type: “G”.

IDEN

TIFIC

ATIO

N

ScrollUNICO.SCROLL range is equipped with latest generation of Scroll compressors to grant the

highest efficiency and reduced noise emission.

Page 131: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

131RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate evaporator •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCROLL.C.STD “G”R407C • 20 ÷ 112 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CentriCentrifugal fan version for

indoor and/or ducted

installations.

HIGH

LIGHT

S

Made2LastHousing designed to last

in time and in any

weather condition.

SpaceSaverInternal components layout

allows full frontal

inspection and maintenance

operations.

Version available with R134a refrigerant chargesee page 274

Page 132: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

132 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.SCROLL.C.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.SCROLL.C.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G3 G3 G3 G5 G5 G5

18,5 21,5 28,3 32,9 45 56,41 1 1 1 1 11 1 1 1 1 1

2000 2000 2000 2600 2600 26001040 1040 1040 1200 1200 12002010 2010 2010 2240 2240 2240590 590 630 840 900 91047 49 51 53 54 58

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G5 G5 G5 G5 G7 G8 G8 G8

30,6 36,3 42,9 55,9 63,2 82,7 91,6 109,32 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2600 2600 2600 2600 3600 5170 5170 51701200 1200 1200 1200 1290 1290 1290 12902240 2240 2240 2240 2010 2050 2050 2050860 880 920 970 1360 1850 1910 197052 55 54 58 55 56 56 56

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

UNICO.SCROLL.C.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with Scroll

compressors and centrifugal fans. Casing type: “G”.

IDEN

TIFIC

ATIO

N

ELN Range (Extremely low noise)Over 20 years of experience in sound reduction techniques together with SCROLL technology enable RC Group to grant excellent

sound emission levels for this equipment.

The result as for all ELN range chillers is achieved by a specific design philosophy concentrated on removing the sound emissions

at "source", without using "bolt-on" acoustic kits that result in detrimental product efficiency, maintenance and durability.

Page 133: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

133RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate evaporator •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCROLL.C.ELN “G”R407C • 18 ÷ 110 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

QuickStartThe supply includes whatever

is needed for a correct unit

working.

For the start-up the units only

need electrical, hydraulic and

cooling connections for a

complete installation in

compliance with all the current

norms.

HIGH

LIGHT

S

ZytelThe special compressor air

supply pipelines made of

patented plastic material

avoid the vibrations

transmission from the

compressor to the

condensing coils reducing the

total noise emission and

avoiding the early materials

decay.

Version available with R134a refrigerant chargesee page 274

Page 134: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

134 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.RECIP.C.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.RECIP.C.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

142.F2 188.F2 220.F2G7 G7 G8

130,5 165,6 193,82 2 22 2 2

3600 3600 51701290 1290 12902010 2010 20501795 1930 238071 71 74

260.F2 300.F2G8 G8237 264,62 22 2

5170 51701290 12902050 20502740 277076 77

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N UNICO.RECIP.C.STD “G”Air cooled packaged liquid chillers equipped with reciprocating compressors and centrifugal fans.

Casing type: “G”.

AdaptiveRangeA wide range of versions and optional for advanced air conditioning systems in big areas and

cooling plants in the industrial field.

Page 135: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

135RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Part winding compressors •

starting system

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.RECIP.C.STD “G”R407C • 130 ÷ 265 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

PumpStationA complete built-in pumping station (without size increase), equipped

with instruments and safety devices totally integrated with the unit

control system in order to emphasize the RC PROACTIVE system;

possibility to integrate PumpStation with water tank without any

increase in footprint.

HIGH

LIGHT

S

BufferTankWater tank to increase plant

inertia with an extreme

reduction of compressors

start-up, harmful for their

reliability and endurance.

Version available with R134a refrigerant chargesee page 274

Page 136: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

136 RC GROUP SpA • General Catalogue • 155.EN.0504

UNICO.RECIP.C.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

142.F2 188.F2 220.F2G8 G8 G8131 165,8 196,32 2 22 2 2

5170 5170 51701290 1290 12902050 2050 20502140 2300 239560 61 67

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

UNICO.RECIP.C.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating

compressors and centrifugal fans. Casing type: “G”.

IDEN

TIFIC

ATIO

N

ELN Range (Extremely low noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise

emission" equipment on the market.

The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and

reducing the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".

This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove

heavy noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with

time, unlike that of the materials of the "bolt-on" sound reduction kits that can decay over time.

Page 137: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

137RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Part winding compressors •

starting system

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.RECIP.C.ELN “G”R407C • 130 ÷ 200 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ServiceFastCompressors, electric board

and electronic control system

housed in a technical

compartment separated from

the air flow to allow standard

maintenance with the unit in

operation.

HIGH

LIGHT

S

MateBuilt-in condensing control system for a stepless air flow modulation

through patented system of dampers directly set on the fans outlet.

Version available with R134a refrigerant chargesee page 274

Page 138: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

138 RC GROUP SpA • General Catalogue• 155.EN.0504

RC GROUP liquid chillers: wide range of units in terms of models, compressors, refrigerants.

FREE-COOLING LIQUID CHILLERSLiquid chillers with built-in indirect SRC free-cooling system are specifically designed to reduce energy consumption wherecooling energy is required even in wintertime and mid-season, as required in air conditioning systems for information technology,

communication and industrial cooling.The units are equipped with a combined system to use outdoor air for water free cooling or precooling.Thanks to a proprietary control logic developed by RC through a 30-year experience in production of these chillers, the energy savingachieved through this type of chillers is always the maximum allowed by the outdoor air temperature, without any compromise.These chillers are available also in OPTIMIZER version, internationally patented, able to multiply the energy savings achieved throughindirect free-cooling solutions specially in areas with a temperate climate. Also this range of units is available both with axial andcentrifugal fans for indoor installations.

ELN RANGE (EXTREMELY LOW NOISE)For over 20 years RC Group has offered a standard catalogued range of units designed specifically to provide the "lowest noiseemission" equipment on the market.The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and reducing theserviceability of the equipment but instead has concentrated on removing the sound emissions at "source".By careful selection of matched components and innovative design of the condensing coil surface and airflow distribution, the ELN rangehas evolved into one of the quietest and thermally efficient Packaged Chillers in today's market place.This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy noise reductionkits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike that of the materials of the"bolt-on" sound reduction kits that can decay over time.All RC Group chillers are available in the ELN range, including versions with axial or centrifugal fans.

PLAN

T TY

PEAir cooled free-cooling liquid chillers

Page 139: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

139RC GROUP SpA • General Catalogue • 155.EN.0504

MAXIMO.SCROLL.A.STD “G” • R407C • 21 ÷ 127 kWFree-cooling liquid chillers with scroll compressors.

MAXIMO.SCROLL.A.ELN “G” • R407C • 22 ÷ 120 kWExtremely low noise free-cooling liquid chillers with scroll compressors.

MAXIMO.RECIP.A.STD “G” • R407C • 146 ÷ 412 kWFree-cooling liquid chillers with reciprocating compressors.

MAXIMO.RECIP.A.ELN “G” • R407C • 137 ÷ 292 kWExtremely low noise free-cooling liquid chillers

with reciprocating compressors.

MAXIMO.RECIP.A.STD “U” • R407C • 486 ÷ 1040 kWFree-cooling liquid chillers with reciprocating semihermetic compressors.

MAXIMO.RECIP.A.ELN “U” • R407C • 323 ÷ 617 kWExtremely low noise free-cooling liquid chillers

with reciprocating compressors.

MAXIMO.RECIP.A.STD “W” • R407C • 1220 ÷ 1610 kWFree-cooling liquid chillers with reciprocating compressors.

MAXIMO.SCREW.A.STD “G” • R407C • 249 ÷ 392 kWFree-cooling liquid chillers with screw compressors.

MAXIMO.SCREW.A.ELN “G” • R407C • 261 ÷ 300 kWExtremely low noise free-cooling liquid chillers with screw compressors.

MAXIMO.SCREW.A.STD “U” • R407C • 472 ÷ 1096 kWFree-cooling liquid chillers with screw compressors.

MAXIMO.SCREW.A.ELN “U” • R407C • 366 ÷ 802 kWExtremely low noise free-cooling liquid chillers with screw compressors.

MAXIMO.SCREW.A.STD “W” • R407C • 1399 ÷ 1869 kWFree-cooling liquid chillers with screw semihermetic compressors.

MAXIMO.SCROLL.C.STD “G” • R407C • 21 ÷ 122 kWFree-cooling liquid chillers with scroll compressors.

MAXIMO.SCROLL.C.ELN “G” • R407C • 22 ÷ 121 kWExtremely low noise free-cooling liquid chillers with scroll compressors.

MAXIMO.RECIP.C.STD “G” • R407C • 140 ÷ 288 kWFree-cooling liquid chillers with reciprocating compressors.

MAXIMO.RECIP.C.ELN “G” • R407C • 138 ÷ 214 kWExtremely low noise free-cooling liquid chillers with reciprocating

compressors.

140 AXIAL FANS

142

144

146

148

150

152

154

156

158

160

162

164 CENTRIFUGAL FANS

166

168

170

Air cooled free-coolingliquid chillers

INDE

X

Page 140: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

140 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCROLL.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.SCROLL.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G0 G0 G2 G2 G4 G4

21,6 23,8 32,5 39,5 53 63,519,2 19,5 29 38,1 49,9 51,5

1 1 1 1 1 11 1 1 1 1 1

1150 1150 2000 2000 2600 26001100 1100 1250 1250 1410 14101640 1640 1690 1690 1690 1690370 370 545 615 840 87062 62 62 64 64 64

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G2 G2 G4 G4 G6 G6 G6 G7

37,1 42,7 50,5 64,1 74,2 94,8 105,2 126,737,6 38,7 49,5 58 70,2 87,9 89,7 117,4

2 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2000 2000 2600 2600 3600 3600 3600 36001250 1250 1410 1410 1560 1560 1560 15601690 1690 1690 1690 1690 1690 1690 2215650 660 890 940 1230 1380 1440 158064 64 64 65 65 66 66 66

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.SCROLL.A.STD “G”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, Scroll compressors

and axial fans. Casing type: “G”.

SCR&MP99 (RC GROUP free-cooling system)RC revealed to be a pioneer in energy saving field applied to air cooled liquid chillers by developing in 1979 the first

(absolutely) chiller with integrated free-cooling system called SCR.

Nowadays RC is the manufacturer with the longest experience in this specific field with thousand of installations all over

the world, from Siberia to South Africa, from Buenos Aires to Beijing through Madrid and London.

MAXIMO.SCROLL represents the latest generation of chillers with free-cooling SCR system and combines RC peerless

experience with SCROLL latest generation technology to grant the quickest return of the investment.

Page 141: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

141RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

Optimizer system •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.SCROLL.A.STD “G”R407C • 21 ÷ 127 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

RCProactiveMP99 microprocessor control and

monitoring system with

technology owned by RC

PROACTIVE, designed to grant

continuity of work even in

emergency situations.

HIGH

LIGHT

S

QuickStartWhatever is needed for a correct

operation is built-in.

Electrical and water connections

only are needed at start-up for a

complete installation in full

compliance with all the current

norms.

Version available with R134a refrigerant chargesee page 274

Page 142: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

142 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCROLL.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.SCROLL.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G2 G2 G4 G4 G5 G5

22,2 24,6 32,1 38,4 52,7 61,523 23,4 29,9 36,8 52,5 53,91 1 1 1 1 11 1 1 1 1 1

2000 2000 2600 2600 2600 26001250 1250 1410 1410 1410 14101690 1690 1690 1690 2240 2240545 545 750 800 1090 109551 51 55 52 55 55

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G4 G4 G5 G7 G7 G7 G7 G836 42,8 50,1 63,4 74,6 90,1 99,4 120,1

36,3 41,1 52 62,5 77,8 87,6 89,1 120,22 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2600 2600 2600 3600 3600 3600 3600 51701410 1410 1410 1560 1560 1560 1560 15901690 1690 2240 2215 2215 2215 2215 2155890 910 1080 1430 1550 1650 1710 207052 55 55 51 55 51 51 53

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.SCROLL.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling

SCR system, Scroll compressors and axial fans. Casing type: “G”.

ELN Range (Extremely low noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise

emission" equipment on the market.

The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and

reducing the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".

This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy

noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike

that of the materials of the "bolt-on" sound reduction kits that can decay over time.

Page 143: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

143RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

Optimizer system •

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.SCROLL.A.ELN “G”R407C • 22 ÷ 120 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

PumpStationA complete built-in pumping

station (without size

increase), equipped with

instruments and safety

devices totally integrated

with the unit control system

in order to emphasize the RC

PROACTIVE system.

ZytelThe special compressor discharge

piped made of patented plastic

material avoid the vibrations

transmission from the compressor

to the condensing coils reducing the

total noise emission and avoiding

the early materials decay.

Version available with R134a refrigerant chargesee page 274

Page 144: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

144 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.RECIP.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.RECIP.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

142.F2 188.F2 220.F2 260.F2 300.F2G7 G8 G8 G8 G8

146,2 183,1 216,4 259,5 285,7117,2 173,6 213,2 220 223,1

2 2 2 2 22 2 2 2 2

3600 5170 5170 5170 51701560 1590 1590 1590 15902115 2155 2155 2215 22152095 2310 2465 2830 286066 66 67 73 73

320.S2 350.F2 385.S2 440.S2G9 G9 G9 G9

325,9 354,8 377,2 412,1254,8 257,8 274,6 275,8

2 2 2 22 2 2 2

5900 5900 5900 59002070 2070 2070 20702470 2470 2470 24705130 4430 5170 518072 72 72 72

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.RECIP.A.STD “G”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, reciprocating

compressors and axial fans. Casing type: “G”.

SCR&MP99 (RC GROUP free-cooling system)MAXIMO chillers control system is based on a RC proprietary software and it is the sum of RC experiences achieved

through thousand of installations all over the world, from Siberia to South Africa, from Buenos Aires to Beijing through

Madrid and London.

The possibility to test SCR system directly in numerous and different climatic situations and in various application fields

(precision and comfort air conditioning, industrial and process cooling for chemical, pharmaceutical, food and mechanical

industry) allowed RC to develop a specific know-how which is not easily achievable by other companies working in the

same field.

This solution brings energy savings that cannot be matched by competitors equipment.

Page 145: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

145RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Part-Winding compressors •

starting system (S)

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Part-Winding compressors •

starting system (F)

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.RECIP.A.STD “G”R407C • 146 ÷ 412 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

MyNoiseSolutions range (STD-LNO) conceived to allow the selection directly

from the catalogue of the most suitable product for the specific

legislative or environmental demands regarding the noise emission

control.

HIGH

LIGHT

S

MateIntegrated condensing

control system for a

stepless speed modulation

of condenser fans.

SCR&MP99The high energy saving of SCR

system is obtained through the RC

proprietary software which

optimizes total or partial free-

cooling cycles according to the

specific climatic and inner load

conditions.

Version available with R134a refrigerant chargesee page 274

Page 146: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

146 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.RECIP.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.RECIP.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

142.F2 188.F2 220.F2G8 G8 G8

137,6 177,2 207,1123 145,8 168,82 2 22 2 2

5170 5170 51701590 1590 15902155 2155 21552225 2370 246553 53 56

260.F2 300.F2G9 G9

256,6 292,1196,7 219,5

2 22 2

5900 59002070 20702470 24703270 339058 61

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.RECIP.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling

SCR system, reciprocating compressors and axial fans. Casing type: “G”.

ELN Range (Extremely low noise)Highest energy saving and lowest sound emission together in the same product.

Thanks to MAXIMO ELN it is possible to take advantage of SCR indirect free-cooling system even in those situations requiring the

lowest noise levels in order to meet specific legislative or environmental demands.

The result as for all ELN range chillers is achieved by a specific design philosophy concentrated on removing the sound emissions

at "source", without using "bolt-on" acoustic kits.

This solution grants continuity of performance in both sound level and cooling capacity. The system is managed by PROACTIVE

logic as all RC microprocessor based control systems.

Page 147: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

147RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Part-Winding compressors •

starting system

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.RECIP.A.ELN “G”R407C • 137 ÷ 292 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

SleepWellProprietary software

for lowest noise

emission working

during the night.

HIGH

LIGHT

S

ServiceFastCompressors, electric board

and electronic control system

housed in a technical

compartment separated from

the air flow to allow standard

maintenance with the unit in

operation.

Version available with R134a refrigerant chargesee page 274

Page 148: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

148 RC GROUP SpA • General Catalogue• 155.EN.0504

Patent

MAXIMO.RECIP.A.STD “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.RECIP.A.STD “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

495.S2 550.S2 600.S2 660.S2U10 U10 U11 U11484 522 597,4 635,9

376,5 380,5 472,9 476,92 2 2 22 2 2 2

5500 5500 6490 64902385 2385 2385 23852430 2430 2430 24305430 5440 6500 650075 75 75 75

770.S2 880.S2 990.S2 1100.S2U12 U13 U14 U14746 848,7 968,6 1040,5

561,3 655,5 753,1 756,92 2 2 22 2 2 2

7480 8470 9460 94602385 2385 2385 23852430 2430 2430 24307860 8840 9310 932076 77 77 77

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.RECIP.A.STD “U”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, reciprocating

compressors and axial fans. Casing type: “U”.

Optimizer®RC Group, once again, has been the first company of its field to manufacture free-cooling chillers up to 1.000 Kw. The

leadership in this market segment is confirmed by a large number of units of this size installed in the last years all over

Europe.

Thanks to the experience reached gradually in these “huge” installations, RC designed and patented a new system to

extend SCR free-cooling system use also in temperate climate areas or to increase the energy savings in cold areas.

The so called OPTIMIZER system is composed by a set of innovations at a hydraulic connections and control software

level. OPTIMIZER is internationally patented.

Page 149: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

149RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Part-Winding compressors •

starting system

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.RECIP.A.STD “U”R407C • 485 ÷ 1040 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

AdaptiveRangeA complete range of models and optional designed for high air

conditioning systems in large installations and in industrial cooling.

HIGH

LIGHT

S

GlycolFreeFree-cooling integrated system for plants where

antifreezer are not allowed.

Version available with R134a refrigerant chargesee page 274

Page 150: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

150 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.RECIP.A.ELN “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.RECIP.A.ELN “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

320.S2 350.F2 385.S2 440.S2U10 U10 U10 U11323 351,3 371,1 421

299,9 304,4 294,6 358,12 2 2 22 2 2 2

5500 5500 5500 64902385 2385 2385 23852430 2430 2430 24305280 4580 5310 620062 62 62 62

495.S2 550.S2 600.S2 660.S2U12 U12 U12 U12

493,4 532,5 580,6 617,7427,5 432,8 439,2 443,2

2 2 2 22 2 2 2

7480 7480 7480 74802385 2385 2385 23852430 2430 2430 24307470 7480 7660 766062 62 62 62

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.RECIP.A.ELN “U”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling

SCR system, reciprocating compressors and axial fans. Casing type: “U”.

ELN Range (Extremely low noise)An extremely compact chilled water production unit with a noise level meeting the most strict demands.

MAXIMO.RECIP.A.ELN “U”, range up to 600 Kw including SCR free-cooling system and RC ELN technology.

Page 151: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

151RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Part-Winding compressors •

starting system

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.RECIP.A.ELN “U”R407C • 323 ÷ 617 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Easy@ServeAll components are

accessible through handy

hinged panels equipped

with antiwind lock, without

removal of heavy noise

deading boxes.

HIGH

LIGHT

S

PumpStationA complete built-in pumping station

(without size increase), equipped

with instruments and safety devices

totally integrated with the unit

control system in order to emphasize

the RC PROACTIVE system.

Version available with R134a refrigerant chargesee page 274

PatentOptimizer®Patented OPTIMIZER system for

variable water flow or; thanks to

this solution it is possible to

extend the application to

temperate climate areas and/or

to appreciably increase the

energy savings obtained through

indirect free-cooling systems.

Page 152: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

152 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.RECIP.A.STD “W” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.RECIP.A.STD “W” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

1210.S3 1320.S3 1420.S3W21 W21 W22

1220,5 1292,3 1429,61058,4 1059,3 1188,4

3 3 33 3 3

10800 10800 118702350 2350 23502610 2610 2610

13650 13815 1489085 85 85

1530.S3 1640.S3W22 W23

1507,7 1612,81197,1 1309,1

3 33 3

11870 129402350 23502610 2610

14895 1582185 85

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.RECIP.A.STD “W”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, reciprocating

compressors and axial fans. Casing type: “W”.

Maximo&DualThe competitors start proposing free-cooling chillers up to 1.000 Kw....... once again RC redefines the field

limits.

MAXIMO W, a range of chillers equipped with SCR system supplying up to 1.610 Kw in a single unit. The range

is in the catalogue, as always, and the reliability is supported by the experience of many units installed on

site. Since many years RC has been developing its know-how on systems, management and components level.

MAXIMO W is equipped with RC Group DUAL compressors which grant up to 550 Kw cooling capacity; the

biggest reciprocating compressor available today on the market.

Page 153: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

153RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of epoxy painted •

galvanized steel sheet

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Part-Winding compressors •

starting system

Step-step cooling capacity control •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.RECIP.A.STD “W”R407C • 1220 ÷ 1610 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CoolingDensityPlusOptimization of internal layout to achieve the best ratio between

footprint and cooling capacity.HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Patent

Dual®RC Group DUAL compressors are equipped with innovative

technologies such as: valves in composite material (covered by

international patent), specifically designed to be used with ester

oils and green refrigerants; compressor built-in filters section is

easy to inspect and maintain; internal spaces are designed to

maximize the efficiency both at full load and at partial loads;

proprietary unloading system; a wide range of innovative design

has been used in the liquid dynamic handling in order to reduce

vibration transmission and overall sound level.

Page 154: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

154 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCREW.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.SCREW.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

230.V1 280.V1 330.V1 370.V1G8 G9 G9 G9

249,1 316,3 363,8 392,3229,5 310,9 310,8 313,8

1 1 1 11 1 1 1

5170 5900 5900 59001590 2070 2070 20702155 2470 2470 24702825 4255 4400 442070 71 71 71

200.V2 240.V2 280.V2 320.V2G8 G8 G9 G9

216,4 265,5 309,2 350,7228,5 230,4 303,4 315,9

2 2 2 22 2 2 2

5170 5170 5900 59001590 1590 2070 20702155 2155 2470 24702860 2870 4245 469071 71 72 72

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.SCREW.A.STD “G”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, screw compressors

and axial fans. Casing type: “G”.

RCProactiveAll MAXIMO range is equipped with microprocessors systems provided with RC PROACTIVE logic conceived to grant

continuity of work even in emergency situations.

For instance: in case of a restart after a possible stop of the units due to a blackout, the proprietary RESTART system

(PROACTIVE logic integrated system), activates a restart procedure granting the chiller in operation even with a return

water high temperature. Usually this situation would cause an immediate stop of the chiller (complete stop with manual

restart need) for high pressure. RESTART is vital in all those plants with high thermal load and low inertia, where even a

few minutes of energy loss (usually time needed for diesel generator start-up) would increase the water temperature in

excess of that possible for any other chiller to start without the RESTART system.

Page 155: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

155RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Star/delta compressors •

starting system

Oil cooling system •

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.SCREW.A.STD “G”R407C • 249 ÷ 392 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

QuickStartWhatever is needed for a correct operation is built-in.

Electrical and water connections only are needed at start-up for

a complete installation in full compliance with all the current

norms.

HIGH

LIGHT

S

MateIntegrated condensing control system for a stepless speed

modulation of condensers fans.

Version available with R134a refrigerant chargesee page 274

Page 156: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

156 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCREW.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.SCREW.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

230.V1 280.V1G9 G9

261,4 300,2255,6 252,8

1 11 1

5900 59002070 20702470 24704175 425559 59

200.V2 240.V2 280.V2G8 G9 G9

208,3 271,9 295,7185,8 255,7 250

2 2 22 2 2

5170 5900 59001590 2070 20702155 2470 24702860 4220 424555 60 69

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.SCREW.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling

SCR system, screw compressors and axial fans. Casing type: “G”.

AntiRumbleHighest energy saving and lowest noise emission together in the same product.

MAXIMO SCREW ELN exploits the typical low vibration operation of screw compressors to obtain a high

performing product at noise reduction level.

The unit base frame is realised with ANTIRUMBLE system and is made of a multiple layer structure with high

noise absorption characteristics, thus allowing the keeping of a high noise efficiency even in cases where the

units are installed in a “raised” position through weight distribution bars and/or antivibration holders.

Page 157: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

157RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Star/delta compressors •

starting system

Oil cooling system •

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.SCREW.A.ELN “G”R407C • 261 ÷ 300 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Made2LastHousing designed to last in time and in bad weather: flexible

capillary piping to avoid problems deriving from copper work

hardening; antivibration holders under the compressors to

reduce vibration transmission to the housing; electric cables

in conduit and metallic cableways; housing in anodized

aluminium; galvanized steel sheet parts; aluminium or stainless

steel small parts.

HIGH

LIGHT

S

FreezeProtectionEvaporator with built-in antifreeze

heater and high thickness insulation,

combined with proprietary software

for the automatic start up of the

pumping group with direct scanning

from the digital antifreeze sensor.

Version available with R134a refrigerant chargesee page 274

Page 158: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

158 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCREW.A.STD “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.SCREW.A.STD “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

420.V1 470.V1 500.V1 550.V1U10 U10 U10 U11

472,9 520,9 543,4 622379 380,4 382,5 480,41 1 1 11 1 1 1

5500 5500 5500 64902385 2385 2385 23852430 2430 2430 24304880 4900 5000 580074 74 74 74

380.V2 460.V2 560.V2 660.V2 740.V2 840.V2 940.V2 1000.V2U10 U10 U11 U12 U12 U113 U14 U14

428,7 507,7 595 705,2 793,6 933,8 1043,7 1096,3373,2 379 477,4 557,6 566,3 665 760,9 765,8

2 2 2 2 2 2 2 22 2 2 2 2 2 2 2

5500 5500 6490 7480 7480 8470 9460 94602385 2385 2385 2385 2385 2385 2385 23852430 2430 2430 2430 2430 2430 2430 24304860 4980 6150 7250 7600 8600 9390 1085075 75 75 76 76 77 77 77

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.SCREW.A.STD “U”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, screw compressors

and axial fans. Casing type: “U”.

ScrewMAXIMO SCREW represents the latest evolution in terms of energy saving granting the best energy

performances in all operating modes, Total Free-Cooling, Partial Free-Cooling and Mechanical Cooling.

SCREW compressors are helical twin high efficiency compressors granting the possibility of multistep or

proportional regulation. They are specifically designed to be used in air cooled chillers (high condensing

temperatures).

Page 159: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

159RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Star/delta compressors •

starting system

Oil cooling system •

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.SCREW.A.STD “U”R407C • 472 ÷ 1096 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

MyNoiseSolutions range (STD-LNO) conceived to

allow the selection directly from the

catalogue of the most suitable product

for the specific legislative or

environmental demands regarding the

noise emission control.

HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Patent

Optimizer®Patented OPTIMIZER system for variable water flow or; thanks

to this solution it is possible to extend the application range to

temperate climate areas and/or to appreciably increase the

energy savings obtained through indirect free-cooling systems.

Page 160: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

160 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCREW.A.ELN “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.SCREW.A.ELN “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

330.V1 370.V1 420.V1 470.V1 500.V1 550.V1U10 U10 U11 U11 U12 U12

366,4 400,9 477,2 515,7 651,5 628310,5 301,3 393 380,1 462,4 450,3

1 1 1 1 1 11 1 1 1 1 1

5500 5500 6490 6490 7480 74802385 2385 2385 2385 2385 23852430 2430 2430 2430 2430 24304830 4850 5400 5580 7050 709061 61 61 61 61 61

320.V2 380.V2 460.V2 560.V2 660.V2 740.V2U10 U10 U11 U12 U13 U14

360,5 407,1 502 601 705,5 802,1309,7 301,9 378,9 447,7 522 602,6

2 2 2 2 2 22 2 2 2 2 2

5500 5500 6490 7480 8470 94602385 2385 2385 2385 2385 23852430 2430 2430 2430 2430 24304840 4890 6000 7300 8100 885062 62 62 62 63 63

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

MAXIMO.SCREW.A.ELN “U”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling SCR

system, screw compressors and axial fans. Casing type: “U”.

ELN Range (Extremely low noise)RC Group experience in sound reduction techniques together with SCREW technology grant sound emission levels never achieved

in chillers with such reduced dimensions.

The result as for all ELN range chillers is achieved by a specific design philosophy concentrated on removing the sound emissions

at "source", without using "bolt-on" acoustic kits that can result in detrimental product efficiency, maintenance and durability.

Screw compressor characteristics reduce the requirement of "heavy weight" acoustic treatment so often required when

using reciprocating compressors.

Screw ELN range allows design compliance to meet specific legislative or environmental acoustic control measures

IDEN

TIFIC

ATIO

N

Page 161: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

161RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Star/delta compressors •

starting system

Oil cooling system •

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.SCREW.A.ELN “U”R407C • 366 ÷ 802 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

GlycolFreeThanks to a system of exchangers set inside the unit,

the free-cooling circuit is 100% protected from

freezing problems, while there is no antifreeze in the

building.

HIGH

LIGHT

S

RCProactiveMicroprocessor control and

monitoring system technology owned

by RC PROACTIVE, designed to grant

continuity of work even in emergency

situations.

Version available with R134a refrigerant chargesee page 274

Page 162: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

162 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCREW.A.STD “W” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

1260.V3 1410.V3 1500.V3 1650.V3W21 W22 W23 W23

1399,3 1525,9 1671,9 1869,31088,6 1196 1333 1332,5

3 3 3 33 3 3 3

10800 11870 12940 129402350 2350 2350 23502610 2610 2610 2610

13830 15000 16100 1625084 84 84 84

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fansTE

CHNI

CAL D

ATA

MAXIMO.SCREW.A.STD “W”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, screw compressors

and axial fans. Casing type: “W”.

IDEN

TIFIC

ATIO

N

RCProactiveMAXIMO W, a range of chillers equipped with SCR system and supplying up to 1.650 Kw for a single unit and with last

generation SCREW compressors. Also MAXIMO W is equipped with RESTART proprietary software.

In case of a restart after a possible stop of the units due to a blackout, this particular system activates a restart

procedure granting the chiller in operation even with a return water high temperature. Usually this situation would cause

an immediate stop of the chiller (complete stop with manual restart need) for high pressure. RESTART is vital in all those

plants with high thermal load and low inertia, where even a few minutes of energy loss (usually time needed for diesel

generator start-up) would increase the water temperature in excess of that possible for any other chiller to start without

the RESTART system.

Page 163: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

163RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of epoxy painted •

galvanized steel sheet

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Star/delta compressors •

starting system

Oil cooling system •

Step-step cooling capacity control •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.SCREW.A.STD “W”R407C • 1399 ÷ 1869 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CoolingDensityPlus1.650 kW in 30 m2 (DF = 55 kW/m2), the free-cooling chiller with

the highest Cooling Density (kW per m2 plant space) available today

on the market.

HIGH

LIGHT

S

ScrewTwin SCREW compressor are helical twin compressors with high

efficiency which grant the possibility of multistep or proportional

regulation and are specifically designed to be used in air cooled

chillers (high condensing temperatures).

Version available with R134a refrigerant chargesee page 274

Page 164: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

164 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCROLL.C.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.SCROLL.C.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G1 G1 G1 G3 G3 G3

20,9 23,8 31,4 38,6 52,1 6217,7 19,5 22,6 35,4 45,8 45,8

1 1 1 1 1 11 1 1 1 1 1

1150 1150 1150 2000 2600 26001100 1100 1100 1250 1410 14101960 1960 1960 2010 2010 2010435 435 460 740 820 84059 59 66 60 68 68

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G3 G3 G3 G3 G5 G7 G7 G7

35,8 42,6 47 61,4 75,6 92,1 101,8 122,133,4 38,3 39,6 45,7 66,3 87,4 89,1 92

2 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2000 2000 2000 2000 2600 3600 3600 36001250 1250 1250 1250 1410 1560 1560 15602010 2010 2010 2010 2010 2010 2010 2010760 780 790 880 1210 1630 1690 173059 60 64 68 70 69 69 69

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.SCROLL.C.STD “G”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, Scroll compressors

and centrifugal fans. Casing type: “G”.

CentriMAXIMO SCROLL represents the latest generation of free-cooling chillers with SCR systems bringing together the vast RC

experience and the SCROLL latest generation technology to grant a more rapid return of the investment.

CENTRI version whose condensing section is equipped with centrifugal fans, allows the use of MAXIMO chillers even for INDOOR

installations. Indeed CENTRI allows the static pressure supplied by the fans section to conform to the possible pressure drops

due to duct system of condensing air intake and/or expulsion.

Page 165: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

165RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

Optimizer system •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.SCROLL.C.STD “G”R407C • 21 ÷ 122 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

AdaptiveRangeMultiple versions, optional

and mountings for a various

range of applications in

continental or cold climate

areas, from 24h/day hi-tech.

applications to nonstop

industrial processes

cooling.

HIGH

LIGHT

S

ScrollMAXIMO.SCROLL range is equipped with last generation SCROLL

compressors to grant the highest efficiency and the lowest noise

emission.

Version available with R134a refrigerant chargesee page 274

Page 166: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

166 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCROLL.C.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.SCROLL.C.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G3 G3 G3 G5 G5 G5

21,8 25 31,9 39,5 53 63,521,2 23,8 27,7 39,2 49,9 51,5

1 1 1 1 1 11 1 1 1 1 1

2000 2000 2000 2600 2600 26001250 1250 1250 1410 1410 14102010 2010 2010 2010 2010 2010660 660 690 980 1060 107048 50 53 52 60 60

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G5 G5 G5 G5 G7 G8 G8 G8

36,5 42,7 48,7 63 74,8 94,5 104,8 121,436,9 39,8 44,3 51,4 72 111,7 114,2 117,4

2 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2600 2600 2600 2600 3600 5170 5170 51701410 1410 1410 1410 1560 1590 1590 15902010 2010 2010 2010 2010 2050 2050 20501020 1030 1040 1110 1450 2060 2120 219051 52 54 60 61 60 60 60

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

MAXIMO.SCROLL.C.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling SCR

system, Scroll compressors and centrifugal fans. Casing type: “G”.

ELN Range (Extremely Low Noise)RC ELN technology applied to MAXIMO free-cooling chillers.

These top levels are the result as for all ELN range chillers of a specific design philosophy concentrated on removing the sound

emissions at "source", without using "bolt-on" acoustic kits.

The use of the latest generation SCROLL compressors highlights the ELN range of characteristics making plant selection of

critical acoustic systems easy.

IDEN

TIFIC

ATIO

N

Page 167: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

167RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

Optimizer system •

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.SCROLL.C.ELN “G”R407C • 22 ÷ 121 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Made2LastHousing designed to last in time and in any weather conditions:

flexible capillary ducting to avoid problems deriving from copper

work hardening; antivibration holders under the compressors to

reduce vibration transmission to the housing; electric cables in

conduit and metallic cableways; housing in anodized aluminium;

galvanized steel sheet parts; aluminium or stainless steel small

parts.

HIGH

LIGHT

S

QuickStartWhatever is needed for a correct operation is built-in. Electrical

and water connections only are needed at start-up for a complete

installation in full compliance with all the current norms.

Version available with R134a refrigerant chargesee page 274

Page 168: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

168 RC GROUP SpA • General Catalogue• 155.EN.0504

Free-cooling liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA MAXIMO.RECIP.C.STD “G” - MODEL

SizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MAXIMO.RECIP.C.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

142.F2 188.F2 220.F2G7 G7 G8

139,3 178,9 210,393,9 102,9 163,6

2 2 22 2 2

3600 3600 51701560 1560 15902010 2010 20501990 2140 276071 71 74

260.F2 300.F2G8 G8

258,5 287,2179,2 187

2 22 2

5170 51701590 15902050 20503130 315576 77

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

MAXIMO.RECIP.C.STD “G”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, reciprocating

compressors and centrifugal fans. Casing type: “G”.

CentriThanks to CENTRI it is now possible to take advantage from the energy savings granted by SCR free-cooling

system even in ducted or INDOOR applications.

CENTRI version allows the adaptation of MAXIMO air performances to plant needs, with regards to air intake

and/or expulsion duct system or to additional pressure drops due to grilles or insulation devices.

IDEN

TIFIC

ATIO

N

Page 169: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

169RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Part-Winding compressors •

starting system

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.RECIP.C.STD “G”R407C • 140 ÷ 288 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CoolingDensityPlusOptimization of internal layout to achieve the best ratio

between footprint and cooling capacity.

PumpStationA complete built-in pumping station (without size increase),

equipped with instruments and safety devices totally integrated

with the unit control system in order to emphasize its working.

HIGH

LIGHT

S

Version available with R134a refrigerant chargesee page 274

Page 170: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

170 RC GROUP SpA • General Catalogue• 155.EN.0504

Free-cooling liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA MAXIMO.RECIP.C.ELN “G” - MODEL

SizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

142.F2 188.F2 220.F2G8 G8 G8

138,5 176,2 213,7119,9 132,6 154,5

2 2 22 2 2

5170 5170 51701590 1590 15902050 2050 20502360 2500 270060 61 67

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

MAXIMO.RECIP.C.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling SCR

system, reciprocating compressors and centrifugal fans. Casing type: “G”.

IDEN

TIFIC

ATIO

N

RCProactiveHighest energy saving, lowest noise emission and possibility to INDOOR installation, all in the same product.

Thanks to MAXIMO ELN CENTRI version, it is possible to take advantage from SCR indirect energy saving system

even in those situations where it is necessary to install the chiller in arranged spaces or to apply additional

acoustic control systems (barriers) in order to achieve the prescribed acoustic parameters. Everything is

managed through PROACTIVE logic, typical of all RC microprocessor controls range.

Page 171: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

171RC GROUP SpA • General Catalogue • 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Part-Winding compressors •

starting system

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.RECIP.C.ELN “G”R407C • 138 ÷ 214 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Easy@ServeAll components are accessible through handy

frontal panels without removal of heavy noise

reduction boxes.HIGH

LIGHT

S

ZytelThe special compressor air supply pipelines made of patented plastic

material avoid the vibrations transmission from the compressor to

the condensing coils reducing the total noise emission and avoiding

the early materials decay.

Version available with R134a refrigerant chargesee page 274

Page 172: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

172 RC GROUP SpA • General Catalogue• 155.EN.0504

RC GROUP liquid chillers: wide range of units in terms of models, compressors and refrigerants.

HEAT PUMPRC GROUP heat pump chillers are available with Scroll, reciprocating and Screw compressors and are characterised by a highenergy efficiency and by a total reliability even in coldest climates, thanks to the control logic of internationally patented IDEA

(Intelligent Defrosting system for Energy saving Applications) defrosting cycles.This dynamic parameters reading logic which is able to identify the real presence of ice on the evaporating coil, allows a 20% energysavings.Moreover, being an autoadaptive logic, it excludes the possibility of regulation parameters choice and can automatically adapt both toworking conditions and to climate.Units are available both with axial and centrifugal fans.

ELN RANGE (EXTREMELY LOW NOISE)For over 20 years RC Group has offered a standard catalogued range of units designed specifically to provide the "lowest noiseemission" equipment on the market.The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and reducing theserviceability of the equipment but instead has concentrated on removing the sound emissions at "source".By careful selection of matched components and innovative design of the condensing coil surface and airflow distribution, the ELN rangehas evolved into one of the quietest and thermally efficient Packaged Chillers in today's market place.This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy noise reductionkits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike that of the materials of the"bolt-on" sound reduction kits that can decay over time.All RC Group chillers are available in the ELN range, including versions with axial or centrifugal fans.

PLAN

T TY

PEHeat pump air cooled liquid chillers

Page 173: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

173RC GROUP SpA • General Catalogue• 155.EN.0504

Heat pump air cooledliquid chillers

EASY.A.P.STD “R” • R407C • 5 ÷ 41 kWHeat pump liquid chillers with scroll compressor.

EASY.A.P.STD “U” • R407C • 47 ÷ 175 kWHeat pump liquid chillers with scroll compressors.

EASY.A.P.STD “W” • R407C • 205 ÷ 450 kWHeat pump liquid chillers with scroll compressors.

CILLI.IDROCOMPL.A.P.STD.Z1 • R407C • 6 ÷ 16 kWIdrocompl heat pump liquid chillers with scroll compressors.

CILLI.IDROCOMPL.A.P.STD.Z2 • R407C • 20 ÷ 50 kWIdrocompl heat pump liquid chillers with scroll compressors.

REVERSO.SCROLL.A.P.STD “G” • R407C • 20 ÷ 112 kWHeat pump liquid chillers with scroll compressors.

REVERSO.SCROLL.A.P.ELN “G” • R407C • 19 ÷ 108 kWExtremely low noise heat pump liquid chillers with scroll compressors.

REVERSO.RECIP.A.P.STD “G” • R407C • 132 ÷ 392 kWHeat pump liquid chillers with reciprocating compressors.

REVERSO.RECIP.A.P.ELN “G” • R407C • 130 ÷ 267 kWExtremely low noise heat pump liquid chillers with reciprocating compr.

REVERSO.RECIP.A.P.STD “U” • R407C • 450 ÷ 980 kWHeat pump liquid chillers with reciprocating compressors.

REVERSO.RECIP.A.P.ELN “U” • R407C • 360 ÷ 780 kWExtremely low noise heat pump liquid chillers with reciprocating compr.

MODULO.RECIP.A.P.STD • R407C • 207 ÷ 480 kWModular heat pump liquid chillers with reciprocating compressor.

REVERSO.SCREW.A.P.STD “G” • R407C • 235 ÷ 376 kWHeat pump liquid chillers with screw compressors.

REVERSO.SCREW.A.P.ELN “G” • R407C • 237 ÷ 312 kWExtremely low noise heat pump liquid chillers with screw compressors.

REVERSO.SCREW.A.P.STD “U” • R407C • 440 ÷ 1117 kWHeat pump liquid chillers with screw compressors.

REVERSO.SCREW.A.P.ELN “U” • R407C • 341 ÷ 832 kWExtremely low noise heat pump liquid chillers with screw compressors.

CILLI.IDROCOMPL.C.P.STD.Z1 • R407C • 6 ÷ 16 kWIdrocompl heat pump liquid chillers with scroll compressor.

CILLI.IDROCOMPL.C.P.STD.Z2 • R407C • 21 ÷ 51 kWIdrocompl heat pump liquid chillers with scroll compressors.

REVERSO.SCROLL.C.P.STD “G” • R407C • 19 ÷ 110 kWHeat pump liquid chillers with scroll compressors.

REVERSO.SCROLL.C.P.ELN “G” • R407C • 18 ÷ 107 kWExtremely low noise heat pump liquid chillers with scroll compressors.

REVERSO.RECIP.C.P.STD “G” • R407C • 126 ÷ 260 kWHeat pump liquid chillers with reciprocating compressors.

REVERSO.RECIP.C.P.ELN “G” • R407C • 130 ÷ 200 kWExtremely low noise heat pump liquid chillers with reciprocating compr.

174 AXIAL FANS

176

178

180

182

184

186

188

190

192

194

196

198

200

202

204

206 CENTRIFUGAL FANS

208

210

212

214

216

INDE

X

Page 174: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

174 RC GROUP SpA • General Catalogue• 155.EN.0504

EASY.A.P.STD “R” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

EASY.A.P.STD “R” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

M.5.Z1 M.6.Z1 M.8.Z1 M.9.Z1R1 R1 R1 R15,2 6,4 7,3 8,56,1 7,5 8,6 10,31 1 1 11 1 1 1

1048 1048 1048 1048460 460 460 460836 836 836 83680 80 82 8357 57 57 57

T.8.1 T.9.Z1 T.11.Z1 T.14.Z1 T.16.Z1 T.18.Z1 T.20.Z1 T.24.Z1 T.28.Z1 T.35.Z1 T.43.Z1R1 R1 R2 R2 R2 R2 R3 R3 R3 R4 R47,4 8,5 10,9 12,6 15,2 17 19,7 23,5 26,8 32,6 418,6 10,3 13,3 15,4 18,5 20,8 24 28,6 32 39,6 50,21 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1

1048 1048 1305 1305 1305 1305 1305 1305 1305 1805 1805460 460 580 580 580 580 580 580 580 580 580836 836 900 900 900 900 1.285 1.285 1.285 1.285 1.28582 83 105 108 115 120 179 194 214 294 30957 57 57 57 60 60 59 59 62 62 62

(1) Data referred to chilled water temperature at 12/7°C; air to condenser at 35°C.(2) Data referred to inlet hot water temperature at 40°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for “M” models • 400.3.50+N for “T” models

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N EASY.A.P.STD “R”Heat pump air cooled packaged liquid chillers equipped with Scroll compressor and axial fans.

ServiceFastHeat pump version of EASY range makes this product the ideal solution for air small/medium air conditioning

systems in all areas where winter temperatures are mild.

Moreover by equipping EASY.P with IDRONICPACK you obtain a “package” needing only hydraulic and electrical

connections to be fully operative and satisfy all year long heat and chill requests.

Page 175: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

175RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing in galvanized steel sheet •

externally coated with PVC film

Plate gas/water heat exchanger •

Microprocessor control system •

Cycle inversion valve •

Antifreeze system •

Water flow control •

Idronic group •

Modulating condensing control •

Remote control board •

RS485 serial line • OPTI

ONAL

EASY.A.P.STD “R”R407C • 5 ÷ 41 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

IdronicPackWater pump and tank in a

single package installed under

the chiller; a complete plant

without any increase in overall

dimensions.

Made2LastHousing designed to last in time

and in any weather condition

thanks to the use of CORROSION

PROOF materials and

technology.

QuickStartWhatever is needed for a

correct operation is built-in.

Electrical and water

connections only are needed

at start-up for a complete

installation in full compliance

with all the current norms.

Page 176: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

176 RC GROUP SpA • General Catalogue• 155.EN.0504

(1) Data referred to chilled water temperature at 12/7°C; air to condenser at 35°C.(2) Data referred to inlet hot water temperature at 40°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA EASY.A.P.STD “U” - MODEL

SizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

EASY.A.P.STD “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

T.50.Z2 T.55.Z2 T.68.Z2 T.84.Z2U5 U5 U6 U6

47,1 54,8 67,1 83,157,9 66,5 80,3 101

2 2 2 21 1 1 1

2000 2000 2580 25801200 1200 1200 12001630 1630 1630 1630750 750 820 84561 61 62 62

T.100.Z2 T.125.Z2 T.150.Z3 T.188.Z3U7 U7 U8 U8

96,1 120,2 141,8 175,5119,7 146,8 177,8 216,9

2 2 3 31 1 1 1

3020 3020 4120 41201200 1200 1800 18001950 1950 1950 19501110 1130 1660 170067 71 69 72

IDEN

TIFIC

ATIO

N EASY.A.P.STD “U”Heat pump air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.

PerformancePlusEASY P with PERFORMANCEPLUS system; up to three scroll type compressors in parallel connection to

grant the maximum energy efficiency in partial load operation, which represents more than 70% of the

yearlong working hours.

PERFORMANCEPLUS system emphasizes the energy saving characteristics granted by IDEA patented

software, proving EASY P heat pumps to be the most efficient solution currently available on the market

from the point of view of the electric consumption.

Page 177: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

177RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing in galvanized steel sheet •

externally coated with PVC film

Plate gas/water heat exchanger •

Microprocessor control system •

Antifreeze system •

Water flow control •

Modulating condensing control •

Cycle inversion valve •

Pump-Down stop •

IDEA defrosting system •

Door lock main switch •

Idronic group •

Remote control board •

RS485 serial line •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

EASY.A.P.STD “U”R407C • 47 ÷ 175 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

MPComThe new generation of RC

microprocessors with

AUTOADAPTIVE logic self-adapting in

real time to the effective working

conditions of the unit according to

precise parameters such as:

water flow, plant inertia, outdoor

air temperature and presence of

antifreeze solutions in the plant.

ServiceFastCompressors, electric board

and electronic control system

housed in a technical

compartment separated from

the air flow to allow standard

maintenance with the unit in

operation.

Page 178: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

178 RC GROUP SpA • General Catalogue• 155.EN.0504

Made2LastHousing designed to last in time and in any weather condition: flexible capillary pipes to avoid problems deriving from

copper work hardening; antivibration holders under the compressors to reduce vibration transmission to the housing;

galvanized steel sheet parts; aluminium or stainless steel small parts.

(1) Data referred to chilled water temperature at 12/7°C; air to condenser at 35°C.(2) Data referred to inlet hot water temperature at 40°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA EASY.A.P.STD “U” - MODEL

SizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

T.200.Z4 T.240.Z4 T.300.Z6 T.360.Z6 T.400.Z6 T..450.Z6W1 W1 W2 W2 W3 W3

205,1 242,1 309,3 366 400 445241,7 285,3 364 430,3 472 520

4 4 6 6 6 62 2 2 2 2 2

2606 2606 3756 3756 4840 48402320 2320 2320 2320 2320 23202490 2490 2490 2490 2490 24901960 2160 2880 3180 3260 336069 73 71 74 75 76

IDEN

TIFIC

ATIO

N

EASY.A.P.STD “W”Heat pump air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.

Page 179: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

179RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing in epoxy painted •

galvanized steel sheet

Plate gas/water heat exchanger •

Microprocessor control system •

Antifreeze system •

Water flow control •

Modulating condensing control •

Cycle inversion valve •

Pump-Down stop •

IDEA defrosting system •

Door lock main switch •

Idronic group •

RS485 serial line •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

EASY.A.P.STD “W”R407C • 205 ÷ 450 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

ScrollThe state of the art technology in the field of medium/small size

compressors to grant excellent performances even in medium

and small dimensions plants.

Patent

Idea®“Patented” defrosting system with dynamic reading of working

parameters. Thanks to proprietary software it senses the real

presence of brine on the coil, it grants defrosting cycles limited to

the real working conditions and brings a remarkable energy saving

(more than 20-30% on the average) and a higher working continuity.

Page 180: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

180 RC GROUP SpA • General Catalogue• 155.EN.0504

CILLI.IDROCOMPL.A.P.STD.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

CILLI.IDROCOMPL.A.P.STD.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

M.7.Z1 M.8.Z1 M.9.Z16,2 6,9 8,37,1 8,1 9,81 1 11 1 1

1242 1242 1242447 447 447844 844 844138 140 14850 50 50

T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z16,9 8,3 12,7 14,5 15,78,1 9,8 14,6 17,1 17,81 1 1 1 11 1 1 1 1

1242 1242 1342 1342 1342447 447 497 497 497844 844 969 969 969140 148 189 199 20950 50 54 54 54

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

(1) Data referred to chilled water temperature at 12/7°C; air to condenser at 35°C.(2) Data referred to inlet hot water temperature at 40°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for “M” models • 400.3.50+N for “T” models

IDEN

TIFIC

ATIO

N CILLI.IDROCOMPL.A.P.STD.Z1Heat pump air cooled packaged liquid chillers equipped with Scroll compressor, axial fan and Idrocompl

system.

Patent

Idrocompl®The high reliability of IDROCOMPL system in heat pump version to meet all air conditioning requirements

12 months a year, in areas with temperate climate.

Easy installation together with NOFREEZE system totally protecting the evaporator from risks of water

freezing, make this product the ideal solution for small air conditioning systems.

Page 181: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

181RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing in galvanized steel sheet •

externally coated with PVC film

IDROCOMPL system •

Microprocessor control system •

Antifreeze system •

On/off condensing control •

Circulation pump •

Modulating condensing control •

Remote control board •

RS485 serial line • OPTI

ONAL

CILLI.IDROCOMPL.A.P.STD.Z1R407C • 6 ÷ 16 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

Pump&PressurePUMP&PRESSURE kit consists of a

built-in circulation pump and of a

water pressure control system.

Through this kit CILLI IDROCOMPL P

becomes a real “package” only

needing electrical and hydraulic

connections to be 100% operating

respecting all the current norms.

Made2LastHousing designed to last in time and in any

weather condition: flexible capillary pipes to

avoid problems deriving from copper work

hardening; antivibration holders under the

compressors to reduce vibration

transmission to the housing; galvanized

steel sheet parts; aluminium or stainless

steel small parts.

Page 182: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

182 RC GROUP SpA • General Catalogue• 155.EN.0504

CILLI.IDROCOMPL.A.P.STD.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

CILLI.IDROCOMPL.A.P.STD.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

T.24.Z2 T.28.Z2 T.34.Z220,4 23,7 27,923,4 26,6 32,4

2 2 21 1 1

1300 1300 1300895 895 895

1645 1645 1645385 395 43561 61 61

T.38.Z2 T.42.Z2 T.50.Z2 T.58.Z231,2 37,2 43,5 49,836,1 42,1 48,7 56,9

2 2 2 21 1 1 1

2000 2000 2000 2000895 895 895 895

1645 1645 1645 1645495 635 665 67062 64 64 64

(1) Data referred to chilled water temperature at 12/7°C; air to condenser at 35°C.(2) Data referred to inlet hot water temperature at 40°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N CILLI.IDROCOMPL.A.P.STD.Z2Heat pump air cooled packaged liquid chillers equipped with Scroll compressors, axial fans and Idrocompl

system.

Patent

Idrocompl®Patented system including in a single device the evaporator, the water tank and the expansion tank.

Page 183: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

183RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

IDROCOMPL system •

Microprocessor control system •

Antifreeze system •

On/off condensing control •

Circulation pump •

Modulating condensing control •

Remote control board •

RS485 serial line •

Spring antivibration holders •

Door lock main switch •

OPTI

ONAL

CILLI.IDROCOMPL.A.P.STD.Z2R407C • 20 ÷ 50 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ServiceFastCompressors, electric board and

electronic control system housed in a

technical compartment separated from

the air flow to allow standard

maintenance with the unit in operation.

9

8

7

6

55

13

12

11

10

2 31 2 4

1. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger

Idrocompl® System

HIGH

LIGHT

S

QuickStartWhatever is needed for a correct

operation is built-in.

Electrical and water connections only are

needed at start-up for a complete

installation in full compliance with all the

current norms.

Page 184: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

184 RC GROUP SpA • General Catalogue• 155.EN.0504

REVERSO.SCROLL.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.SCROLL.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G0 G0 G2 G2 G2 G4

20,3 23,2 32,5 36,7 49,3 56,523,6 26,6 35,6 42,2 55,4 66,9

1 1 1 1 1 11 1 1 1 1 1

1150 1150 2000 2000 2000 2600895 895 1040 1040 1040 1200

1640 1640 1690 1690 1690 1690350 350 500 560 610 77062 62 62 64 64 64

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G2 G2 G2 G4 G4 G6 G6 G6

34,2 39,7 44,6 57 68,4 86,3 96,1 112,340,1 47,1 54,5 69,2 83,2 100,8 113 134,3

2 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2000 2000 2000 2600 2600 3600 3600 36001040 1040 1040 1200 1200 1290 1290 12901690 1690 1690 1690 1690 1690 1690 1690600 620 640 850 890 1210 1270 127064 64 64 64 65 66 66 66

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N REVERSO.SCROLL.A.P.STD “G”Heat pump air cooled packaged liquid chillers equipped with Scroll compressors and axial fans. Casing

type: “G”.

PerformancePlusPERFORMANCEPLUS system emphasizes the energy saving characteristics granted by IDEA patented software, proving

REVERSO SCROLL heat pumps to be the most efficient solution currently available on the market from the point of view of the

electric consumption.

Page 185: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

185RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate gas/water heat exchanger •

Microprocessor control system •

Cycle inversion valve •

Step-step condensing control •

Pump-Down stop •

IDEA defrosting system •

Differential pressure switch •

on water side

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.SCROLL.A.P.STD “G”R407C • 20 ÷ 112 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

MyNoiseSolutions range (STD-LNO) conceived to allow the selection

directly from the catalogue of the most suitable product for the

specific legislative or environmental demands regarding the noise

emission control.

HIGH

LIGHT

S

Patent

IDEA®“Patented” defrosting system with

dynamic reading of working parameters.

Thanks to proprietary software it senses

the real presence of brine on the coil, it

grants defrosting cycles limited to the

real working conditions and brings a

remarkable energy saving (more than

20-30% on the average) and a higher

working continuity.

Page 186: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

186 RC GROUP SpA • General Catalogue• 155.EN.0504

REVERSO.SCROLL.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.SCROLL.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G2 G2 G2 G4 G4 G4

18,8 21,6 29 34,4 45,2 54,323,5 27 35 41,5 54,3 66,9

1 1 1 1 1 11 1 1 1 1 1

2000 2000 2000 2600 2600 26001040 1040 1040 1200 1200 12001690 1690 1690 1690 1690 1690480 480 520 700 790 81050 53 51 53 54 55

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G4 G4 G4 G4 G6 G7 G7 G7

32,3 37,7 43,7 54,6 62,8 79,8 87,6 107,839,5 46,7 53,9 69,2 80,9 96,3 107,3 133,9

2 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2600 2600 2600 2600 3600 3600 3600 36001200 1200 1200 1200 1290 1290 1290 12901690 1690 1690 1690 1690 2215 2215 2215750 780 780 850 1150 1260 1320 137053 51 55 55 53 56 56 57

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

REVERSO.SCROLL.A.P.ELN “G”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with Scroll

compressors and axial fans. Casing type: “G”.

IDEN

TIFIC

ATIO

N

ELN Range (Extremely low noise)RC ELN design technology applied to heat pumps.

Thanks to a specific design philosophy concentrated on removing the sound emissions at "source", REVERSO ELN range

requires no additional hardware that can result in detrimental product efficiency, maintenance and durability.

In this way the product achieves easy selection, installation and maintenance, granting cooling and acoustic performan-

ce and durability in time.

Page 187: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

187RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate gas/water heat exchanger •

Microprocessor control system •

Cycle inversion valve •

Step-step condensing control •

Pump-Down stop •

IDEA defrosting system •

Differential pressure switch •

on water side

Door lock main switch •

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.SCROLL.A.P.ELN “G”R407C • 19 ÷ 108 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

AdaptiveRangeA great variety of versions, models, optional and mountings to

satisfy a wide applications spectrum in air conditioning plants

for comfort, or advanced services in areas with mild climate.

HIGH

LIGHT

S

PumpStationA complete built-in pumping

station (without size

increase), equipped with

instruments and safety

devices totally integrated

with the unit control system

in order to emphasize its

working.

RCProactivePossibility to integrate PumpStation with water tank without

any unit dimensions increase.

Page 188: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

188 RC GROUP SpA • General Catalogue• 155.EN.0504

REVERSO.RECIP.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.RECIP.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

142.F2 188.F2 220.F2 260.F2 300.F2G7 G7 G8 G8 G8

132,3 169,4 201,4 239,2 264,9150,8 188,9 222,5 265,3 298,6

2 2 2 2 22 2 2 2 2

3600 3600 5170 5170 51701290 1290 1290 1290 12902115 2115 2155 2215 22151665 1790 2240 2490 254066 66 67 73 73

320.S2 350.F2 385.S2 440.S2G9 G9 G9 G9

308,8 332,7 352,9 392333,3 389,6 388,4 429,8

2 2 2 22 2 2 2

5900 5900 5900 59001540 1540 1540 15402470 2470 2470 24704105 3397 4199 420974 74 74 74

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N REVERSO.RECIP.A.P.STD “G”Heat pump air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.

Casing type: “G”.

Made2LastMedium capacity heat pump liquid chillers designed and built using MADE2LAST technology: flexible capillary pipes

to avoid problems deriving from copper work hardening; antivibration holders under the compressors to reduce

vibration transmission to the housing; housing in anodized aluminium; galvanized steel sheet parts; aluminium or

stainless steel small parts.

A housing designed to last in time and in any weather condition.

Page 189: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

189RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Part-Winding compressors •

starting system (S)

Step-step cooling capacity control •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Part-Winding compressors •

starting system (F)

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.RECIP.A.P.STD “G”R407C • 132 ÷ 392 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

BufferTankWater tank to increase plant

inertia with an important

reduction of compressors

start and stop for more

reliability and operating life.

HIGH

LIGHT

S

ServiceFastCompressors, electric board

and electronic control system

housed in a technical

compartment separated from

the air flow to allow standard

maintenance with the unit in

operation.

Page 190: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

190 RC GROUP SpA • General Catalogue• 155.EN.0504

REVERSO.RECIP.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.RECIP.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

142.F2 188.F2 220.F2G8 G8 G8

129,1 163,7 187,7147,7 183,8 210,1

2 2 22 2 2

5170 5170 51701290 1290 12902155 2155 21551940 2045 222054 54 57

260.F2 300.F2G9 G9

236,1 267,3267,4 307

2 22 2

5900 59001540 15402470 24702790 291060 63

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

REVERSO.RECIP.A.P.ELN “G”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating

compressors and axial fans. Casing type: “G”.

IDEN

TIFIC

ATIO

N

ELN Range (Extremely Low Noise)The redesign of the range to achieve excellence noise level typical of ELN logic, keeps REVERSO product

among the highest category levels for easy installation and maintenance characteristics, even when it is

proposed in EXTREMELY LOW NOISE version.

All operations control is remitted to MP99 microprocessor system, equipped with RC PROACTIVE

proprietary software, to grant continuity of work even in emergency situations.

Page 191: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

191RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Part-Winding compressors •

starting system

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.RECIP.A.P.ELN “G”R407C • 130 ÷ 267 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

SleepWellProprietary software for

lowest noise emission working

during the night.

HIGH

LIGHT

S

AntirumbleRigid base frame made of a multiple

layer structure with high noise

absorption characteristics, to reduce

the noise emission from the bottom of

the unit.

It is an essential component for all

those installations where the units are

installed “raised” from the floor

through weight distribution bars and/

or antivibration holders.

Page 192: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

192 RC GROUP SpA • General Catalogue• 155.EN.0504

REVERSO.RECIP.A.P.STD “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.RECIP.A.P.STD “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

495.S2 550.S2 600.S2 660.S2U10 U10 U11 U11

456,2 491,5 553,2 588501,9 542,1 612 650,2

2 2 2 22 2 2 2

5500 5500 6490 64902130 2130 2130 21302430 2430 2430 24305114 5119 5700 570076 76 76 76

770.S2 880.S2 990.S2 1100.S2U13 U13 U14 U14

714,9 795,5 901 976,6794 882,6 995,6 1075,72 2 2 22 2 2 2

8470 8470 9460 94602130 2130 2130 21302430 2430 2430 24307051 7216 7892 789778 78 78 78

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

IDEN

TIFIC

ATIO

N REVERSO.RECIP.A.P.STD “U”Heat pump air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.

Casing type: “U”.

REVERSO “U” range includes heat pump liquid chillers up to 1.000 kW capacity, among the biggest available on the market

today. This allows to considerably reduce spaces and hydraulic and electrical connections in large air conditioning

systems.

This solution grants high installation and management savings. Moreover, the reduced number of compressors/fans used to

achieve these capacities decreases the risk rate usually considered as directly proportional to the number of moving

parts. RC is among the world leaders in this specific field, with hundred of installations realised with REVERSO liquid

chillers of capacity between 750 and 1.000 kW, indeed an experience hardly comparable.

Page 193: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

193RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Part-Winding compressors •

starting system

Step-step cooling capacity control •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.RECIP.A.P.STD “U”R407C • 450 ÷ 980 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CoolingDensityPlus1.000 kW cooling/heating capacity “package” in 20 m2 only.HI

GHLIG

HTS

PumpStationMoreover, adding PUMPSTATION, a real built-in pumping station, the

heat station turns to be immediately operative simply by making all

the electrical and hydraulic connections.

Page 194: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

194 RC GROUP SpA • General Catalogue• 155.EN.0504

REVERSO.RECIP.A.P.ELN “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.RECIP.A.P.ELN “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

320.S2 350.F2 385.S2 440.S2 495.S2U10 U10 U11 U11 U12314 341,1 364,9 407,7 465,7

347,2 406,2 403,7 448,8 512,72 2 2 2 22 2 2 2 2

5500 5500 6490 6490 74802130 2130 2130 2130 21302430 2430 2430 2430 24304790 4082 4750 5360 547063 63 63 63 63

550.S2 600.S2 660.S2 770.S2 880.S2U12 U13 U13 U14 U14

503,8 558,3 594,6 703,8 780,1554,8 615,9 654,4 791,9 878,9

2 2 2 2 22 2 2 2 2

7480 8470 8470 9460 94602130 2130 2130 2130 21302430 2430 2430 2430 24305680 5870 5870 6850 731063 64 64 64 64

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

IDEN

TIFIC

ATIO

N REVERSO.RECIP.A.P.ELN “U”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating

compressors and axial fans. Casing type: “U”.

ELN Range (Extremely Low Noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise emission"

equipment on the market.

The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and reducing

the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".

This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy

noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike

that of the materials of the "bolt-on" sound reduction kits that can decay over time.

Page 195: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

195RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Part-Winding compressors •

starting system

Step-step cooling capacity control •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.RECIP.A.P.ELN “U”R407C • 360 ÷ 780 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

Easy@ServeAll components are accessible through handy hinged panels

equipped with antiwind lock, without removal of heavy noise

deading boxes.

Patent

Idea®“Patented” defrosting system with dynamic reading of

working parameters. Thanks to proprietary software it

senses the real presence of brine on the coil, it grants

defrosting cycles limited to the real working conditions and

brings a remarkable energy saving (more than 20-30% on the

average) and a higher working continuity.

Page 196: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

196 RC GROUP SpA • General Catalogue• 155.EN.0504

MODULO.RECIP.A.P.STD - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

MODULO.RECIP.A.P.STD - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

220.S1 330.S1207,1 293,1220,5 329,3

1 11 1

2830 28302300 23002395 23952970 325077 78

440.S1 550.S1392 477,3

431,1 529,21 11 1

2830 28302300 23002395 23953400 357080 80

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

MODULO.RECIP.A.P.STDHeat pump air cooled packaged liquid chillers equipped with reciprocating compressor and axial

fans.

IDEN

TIFIC

ATIO

N

CoolingDensityPlusAll RC Group experience in large capacity Heat Pump concentrated in an extremely small space thanks to COOLING DENSITY

PLUS system.

480 kW of cooling capacity and 530 kW of heating in only 6,5 m2 grant MODULO the record as a heat pump liquid chiller with

the highest Cooling Density (kW per m2 plant space) available on the market today (CD = 82 kW/m2).

Page 197: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

197RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of epoxy painted •

galvanized steel sheet

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Part-Winding compressors •

starting system

Step-step cooling capacity control •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MODULO.RECIP.A.P.STDR407C • 207 ÷ 480 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

SideBySideMODULO is designed to be installed side by side to obtain

very high cooling capacities in reduced areas (for instance

2 MW in only 26 m2!).HIGH

LIGHT

S

PumpStationA complete built-in pumping station (without size increase), equipped

with instruments and safety devices totally integrated with the unit

control system in order to emphasize RC PROACTIVE working.

4in40Thanks to 4in40 size system, four

MODULO chillers can be loaded into

a container, thus severely

reducing transport costs.

Page 198: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

198 RC GROUP SpA • General Catalogue• 155.EN.0504

REVERSO.SCREW.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.SCREW.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimension Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

230.V1 280.V1 330.V1 370.V1G8 G9 G9 G9

235 272,6 332 371,6289,8 335,6 395,3 450,8

1 1 1 11 1 1 1

5170 5900 5900 59001290 1540 1540 15402155 2470 2470 24702485 3255 3375 340071 72 72 72

200.V2 240.V2 280.V2 320.V2 380.V2G8 G8 G9 G9 G9

204,5 242,9 272,3 326,9 376,8254,1 314,6 340,2 394,3 463,1

2 2 2 2 22 2 2 2 2

5170 5170 5900 5900 59001290 1290 1540 1540 15402155 2155 2470 2470 24702425 2530 3300 3665 375972 72 73 73 73

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N REVERSO.SCREW.A.P.STD “G”Heat pump air cooled packaged liquid chillers equipped with screw compressors and axial fans.

Casing type: “G”.

Patent

IDEA®Medium capacity heat pump liquid chillers equipped with last generation screw compressors to emphasize high efficiency

characteristics granted by patented defrosting system IDEA.

IDEA is the first system with dynamic reading of working parameters directly included in the built-in management system of

the unit. Thanks to the proprietary software, it senses the real presence of brine on the coil, grants defrosting cycles

limited to the real working conditions and brings a remarkable energy saving (more than 20-30% on the average) and a

higher working continuity.

Page 199: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

199RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Oil cooling system •

Star/delta compressors starting system •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.SCREW.A.P.STD “G”R407C • 235 ÷ 376 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

MyNoiseSolutions range (STD-LNO) conceived to allow the selection

directly from the catalogue of the most suitable product for the

specific legislative or environmental demands regarding the

noise emission control.

HIGH

LIGHT

S

AntirumbleRigid base frame made of a multiple layer structure with high noise

absorption characteristics, to reduce the noise emission from the

bottom of the unit. It is an essential component for all those installations

where the units are installed “raised” from the floor through weight

distribution bars and/or antivibration holders.

Page 200: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

200 RC GROUP SpA • General Catalogue• 155.EN.0504

REVERSO.SCREW.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.SCREW.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

230.V1 280.V1G9 G9

237,8 279289,5 339,2

1 11 1

5900 59001540 15402470 24703075 315560 60

200.V2 240.V2 280.V2 320.V2G8 G9 G9 G9

200,1 246,9 278,6 312,7258,5 314,2 343,6 398,5

2 2 2 22 2 2 2

5170 5900 5900 59001290 1540 1540 15402155 2470 2470 24702425 3280 3300 366556 61 61 61

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N REVERSO.SCREW.A.P.ELN “G”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with screw

compressors and axial fans. Casing type: “G”.

ELN Range (Extremely Low Noise)The particular noise emissions characterising screw compressors emphasizes the results obtained thanks to the redesign in ELN

version of the range, achieving excellent noise levels hardly to be found in the market.

At any rate REVERSO preserves the easiest installation and maintenance levels of its category.

SLEEPWELL proprietary system highlights the unit lowest noise emission during the night hours.

Page 201: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

201RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Oil cooling system •

Star/delta compressors starting system •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.SCREW.A.P.ELN “G”R407C • 237 ÷ 312 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Easy@ServeAll components are accessible through frontal panels,

without removal of heavy noise deading boxes.HIGH

LIGHT

S

RCProactiveAll operations control is carried out by MP99 microprocessor

system, equipped with RC PROACTIVE proprietary logic to grant

continuity of work even in emergency situations.

Page 202: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

202 RC GROUP SpA • General Catalogue• 155.EN.0504

REVERSO.SCREW.A.P.STD “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.SCREW.A.P.STD “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

420.V1 470.V1 500.V1 550.V1U10 U10 U10 U11

440,3 471,9 492,4 577,2508,2 546,3 572,3 672,4

1 1 1 11 1 1 1

5500 5500 5500 64902130 2130 2130 21302430 2430 2430 24304380 4400 4450 500075 75 75 75

460.V2 560.V2 660.V2 740.V2 840.V2 940.V2 1000.V2 1100.V2U10 U11 U11 U12 U13 U13 U14 U14

463,9 563,8 658,4 726,7 843,8 917,6 990,6 1117,2554,8 671,5 803,9 867,3 978,4 1095,6 1145,8 1335,6

2 2 2 2 2 2 2 22 2 2 2 2 2 2 2

5500 6490 6490 7480 8470 8470 9460 94602130 2130 2130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 2430 2430 24304480 5400 5410 6200 7300 7330 8050 807076 76 76 77 78 78 79 79

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N REVERSO.SCREW.A.P.STD “U”Heat pump air cooled packaged liquid chillers equipped with screw compressors and axial fans.

Casing type: “U”.

The use of large screw compressors allows us to propose a range of heat pump liquid chillers with capacity up to

1.100 kW, indeed amongst the largest available on the market today. Thanks to this solution it is possible to meet the

most strict needs in terms of occupied spaces and hydraulic and electrical connections in large air conditioning

systems.

The results are great installation and operational savings. Moreover the reduced number of compressors/fans used

to achieve these capacities decreases the risk probability usually considered as directly proportional to the number

of moving parts.

Page 203: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

203RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Oil cooling system •

Star/delta compressors starting system •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.SCREW.A.P.STD “U”R407C • 440 ÷ 1117 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

PumpStationThanks to PUMPSTATION, a

complete built-in pumping

station, the heat station turns

to be immediately operative

simply by making all the

electrical and hydraulic

connections.

HIGH

LIGHT

S

ScrewTwin SCREW high efficiency compressors granting the possibility of

multistep or proportional regulation. They are specifically designed

to be used in air cooled chillers (high condensing temperatures).

Page 204: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

204 RC GROUP SpA • General Catalogue• 155.EN.0504

REVERSO.SCREW.A.P.ELN “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.SCREW.A.P.ELN “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

330.V1 370.V1 420.V1 470.V1 500.V1 550.V1U10 U10 U10 U11 U11 U12341 374,5 423,4 474,8 500,7 580,7410 450,5 512,2 558,7 588,3 6851 1 1 1 1 11 1 1 1 1 1

5500 5500 5500 6490 6490 74802130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 24304000 4050 4400 4950 4990 550062 62 62 62 62 62

380.V2 460.V2 560.V2 660.V2 740.V2 840.V2U10 U11 U12 U12 U13 U14

379,8 476,2 561 647,2 726,1 832,5462,7 566,9 681,3 809,7 904,2 1003,7

2 2 2 2 2 22 2 2 2 2 2

5500 6490 7480 7480 8470 94602130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 24304300 4950 5880 5900 6750 780063 63 63 64 64 64

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Heat pump liquid chillers with axial fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N REVERSO.SCREW.A.P.ELN “U”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with screw

compressors and axial fans. Casing type: “U”.

ELN Range (Extremely Low Noise)Screw compressors meet perfectly RC Group ELN (Extremely Low Noise) design.

High frequencies noise emission together with the almost absent vibrations, typical of screw compressors, allow the total

concentration of the design on the condensing part.

This attention produces a highly valuable product from the energy point of view (highest efficiency), with easy maintenance

(without any “heavy” noise deading box) and a durability of acoustic performances in time (noise deading materials decay).

Page 205: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

205RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Oil cooling system •

Star/delta compressors starting system •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.SCREW.A.P.ELN “U”R407C • 341 ÷ 832 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ServiceFastCompressors, electric board and electronic control system

housed in a technical compartment separated from the air flow to

allow standard maintenance with the unit in operation.HIGH

LIGHT

S

Patent

IDEA®As for all RC Group heat pump liquid chillers, this range products are

standard equipped with IDEA patented system for the control of

defrosting cycles through dynamic reading of working parameters.

IDEA is perfectly integrated with unit management and control system

to emphasize RC PROACTIVE working mode, granting in the mean time a

high energy saving (more of 20-30% on the average) and a higher

working continuity.

Page 206: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

206 RC GROUP SpA • General Catalogue• 155.EN.0504

CILLI.IDROCOMPL.C.P.STD.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

CILLI.IDROCOMPL.C.P.STD.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

M.7.Z1 M.8.Z1 M.9.Z16,1 6,8 8,17 8 9,61 1 11 1 1

1242 1242 1242447 447 447844 844 844143 143 15358 58 58

T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z16,8 8,1 12,6 14,1 15,68 9,6 14,5 16,7 17,71 1 1 1 11 1 1 1 1

1242 1242 1342 1342 1342447 447 497 497 497844 844 969 969 969145 153 189 204 24458 58 64 64 64

Heat pump liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”

IDEN

TIFIC

ATIO

N CILLI.IDROCOMPL.C.P.STD.Z1Heat pump air cooled packaged liquid chillers equipped with Scroll compressor centrifugal fan and

Idrocompl system.

CentriHigh reliability of IDROCOMPL system in heat pump version to meet all air conditioning requirements 12

months a year, in mild climate areas.

CENTRI version, with centrifugal fans for indoor and/or ducted installations makes this product the best

solution for small areas air conditioning, where the outdoor installation is not possible due to space and

environmental reasons.

Page 207: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

207RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing in galvanized steel sheet •

externally coated with PVC film

IDROCOMPL system •

Microprocessor control system •

Antifreeze system •

On/off condensing control •

Circulation pump •

Modulating condensing control •

Remote control board •

RS485 serial line •

Spring antivibration holders •

Door lock main switch •

OPTI

ONAL

CILLI.IDROCOMPL.C.P.STD.Z1R407C • 6 ÷ 16 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Pump&PressurePUMP&PRESSURE kit consists of a

circulation pump installed inside the

unit and of a control system of the

water plant pressure. Through this

kit CILLI IDROCOMPL P becomes a real

heat station only needing electrical

and hydraulic connections to be 100%

operating respecting all the current

norms.

HIGH

LIGHT

S

NoFreezeAnti-freeze system that totally

prevents the risks of freezing water

inside the evaporator.

Page 208: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

208 RC GROUP SpA • General Catalogue• 155.EN.0504

CILLI.IDROCOMPL.C.P.STD.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

CILLI.IDROCOMPL.C.P.STD.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

T.24.Z2 T.28.Z2 T.34.Z220,7 24,8 28,723,6 26,9 32,9

2 2 21 1 1

1300 1300 1300895 895 895

1645 1645 1645465 470 48066 66 66

T.38.Z2 T.42.Z2 T.50.Z2 T.58.Z232,3 37,6 44,1 50,836,8 42,4 49 57,4

2 2 2 21 1 1 1

2000 2000 2000 2000895 895 895 895

1645 1645 1645 1645490 760 765 77068 69 69 69

Heat pump liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

IDEN

TIFIC

ATIO

N CILLI.IDROCOMPL.C.P.STD.Z2Heat pump air cooled packaged liquid chillers equipped with Scroll compressors, centrifugal fans

and Idrocompl system.

Made2LastEven CILLI range heat pump liquid chillers are built according to MADE2LAST logic, usual for RC Group high capacity liquid chillers. A

housing designed to last in time and in any weather condition: flexible capillary pipes to avoid problems deriving from copper work

hardening; antivibration holders under the compressors to reduce vibration transmission to the housing; housing in anodized

aluminium; galvanized steel sheet parts; aluminium or stainless steel small parts.

Page 209: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

209RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

IDROCOMPL system •

Microprocessor control system •

Antifreeze system •

On/off condensing control •

Circulation pump •

Modulating condensing control •

Remote control board •

RS485 serial line •

Spring antivibration holders •

Door lock main switch •

OPTI

ONAL

CILLI.IDROCOMPL.C.P.STD.Z2R407C • 21÷ 51 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

ScrollThe state of the art technology in the field of medium/small size

compressors to grant excellent performances even in medium

and small dimensions plants.

Moreover SCROLL compressors grant a very high reliability

rate (MTBF) even in presence of reduced maintenance routine

plants.

9

8

7

6

55

13

12

11

10

2 31 2 4

1. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger

Idrocompl® system

Patent

Idrocompl®Patented system including evaporator,

water tank and expansion tank in a

single component.

Page 210: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

210 RC GROUP SpA • General Catalogue• 155.EN.0504

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G1 G1 G1 G3 G3 G3

18,9 21,4 28,6 34,9 46,2 55,622,8 26,1 34,3 41,1 53,8 66,3

1 1 1 1 1 11 1 1 1 1 1

1150 1150 1150 2000 2000 2000895 895 895 1040 1040 1040

1960 1960 1960 2010 2010 2010410 410 455 690 760 78059 59 66 60 68 68

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G3 G3 G3 G3 G5 G7 G7 G7

32,3 37,5 42,5 56 68,4 82,7 91,4 109,638,7 45,7 52,2 68,5 83,2 96,5 107,6 132,6

2 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2000 2000 2000 2000 2600 3600 3600 36001040 1040 1040 1040 1200 1290 1290 12902010 2010 2010 2010 2240 2010 2010 2010720 740 750 820 1090 1480 1540 157059 60 64 68 70 69 69 69

Heat pump liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

REVERSO.SCROLL.C.P.STD “G”Heat pump air cooled packaged liquid chillers equipped with Scroll compressors and centrifugal fans.

Casing type: ”G”.

IDEN

TIFIC

ATIO

N

REVERSO SCROLL represents the latest generation of heat pump liquid chillers with IDEA patented dynamic defrosting system

and combines current SCROLL technology with RC 40-year experience to grant investment durability in time.

CENTRI version, whose condensing section is equipped with centrifugal fans, allows the use of REVERSO liquid chillers even in

INDOOR installations.

REVERSO.SCROLL.C.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.SCROLL.C.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

Page 211: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

211RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.SCROLL.C.P.STD “G”R407C • 19 ÷ 110 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CentriCENTRI allows the static pressure supplied by the fan

section to conform to the possible pressure drops due to

duct system of condensing air intake and/or expulsion.

HIGH

LIGHT

S

AdaptiveRangeA great variety of versions,

models and optional extras to

meet many requirements in hi-

tech., hotels, cinemas and

shopping centres air

conditioning systems in any

climate condition.

Easy@ServeAll components are accessible

through frontal panels, without

removal of heavy noise deading

boxes.

Page 212: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

212 RC GROUP SpA • General Catalogue• 155.EN.0504

21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G3 G3 G3 G5 G5 G5

18,3 21,1 28,1 32,6 44,3 55,223,2 26,8 35,2 40,6 53,9 67,4

1 1 1 1 1 11 1 1 1 1 1

2000 2000 2000 2600 2600 26001040 1040 1040 1200 1200 12002010 2010 2010 2240 2240 2240610 610 650 860 920 93047 49 51 53 54 58

36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G5 G5 G5 G5 G7 G8 G8 G8

30,3 35,9 42,2 55,6 62,7 81,7 90,2 107,138,3 45,7 53,1 69,7 79,3 97,6 109 133,7

2 2 2 2 2 2 2 22 2 2 2 2 2 2 2

2600 2600 2600 2600 3600 5170 5170 51701200 1200 1200 1200 1290 1290 1290 12902240 2240 2240 2240 2010 2050 2050 2050890 910 950 1000 1390 1880 1940 200052 55 54 58 55 56 56 56

Heat pump liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

REVERSO.SCROLL.C.P.ELN “G”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with Scroll

compressors and centrifugal fans. Casing type: ”G”.

IDEN

TIFIC

ATIO

N

ELN Range (Extremely Low Noise)RC ELN design technology applied to REVERSO heat pumps.

Thanks to a specific design philosophy concentrated on removing the sound emissions at "source", REVERSO ELN

range requires no additional hardware that can result in detrimental product efficiency, maintenance and durability.

The use of the latest generation SCROLL compressors highlights the ELN range of characteristics making plant

selection of critical acoustic systems easy.

REVERSO.SCROLL.C.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.SCROLL.C.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

Page 213: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

213RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.SCROLL.C.P.ELN “G”R407C • 18 ÷ 107 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Made2LastHousing designed to last in time and in any weather condition:

flexible capillary pipes to avoid problems deriving from copper

work hardening; antivibration holders under the compressors to

reduce vibration transmission to the housing; housing in anodized

aluminium; galvanized steel sheet parts; aluminium or stainless

steel small parts.

HIGH

LIGHT

S

AntirumbleRigid base frame made of a

multiple layer structure with high

noise absorption characteristics,

to reduce the noise emission

from the bottom of the unit. It is

an essential component for all

those installations where the

units are installed “raised” from

the floor through weight

distribution bars and/or

antivibration holders.

Page 214: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

214 RC GROUP SpA • General Catalogue• 155.EN.0504

142.F2 188.F2 220.F2G7 G7 G8

126,4 165,7 193,5141,9 187,9 215,5

2 2 22 2 2

3600 3600 51701290 1290 12902010 2010 20501810 1975 251071 71 74

260.F2 300.F2G8 G8

233,9 260,3263,4 298,3

2 22 2

5170 51701290 12902050 20502775 283076 77

Heat pump liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

REVERSO.RECIP.C.P.STD “G”Heat pump air cooled packaged liquid chillers equipped with reciprocating compressors and centrifugal

fans. Casing type: ”G”.

IDEN

TIFIC

ATIO

N

CentriThanks to CENTRI it is now possible to take advantage from the energy savings granted by IDEA patented

defrosting system even in INDOOR or ducted applications.

CENTRI version allows REVERSO air performances to conform to plant needs, about the need to duct the air

intake and/or expulsion or regarding the additional pressure drops due to grilles and/or insulating

systems.

REVERSO.RECIP.C.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

REVERSO.RECIP.C.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

Page 215: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

215RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Part-Winding compressors •

starting system

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.RECIP.C.P.STD “G”R407C • 126 ÷ 260 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CoolingDensityPlusOptimization system of internal layout to achieve the best

ratio between footprint and cooling capacity.

HIGH

LIGHT

S

MyNoiseSolutions range (STD-LNO) conceived to allow the selection

directly from the catalogue of the most suitable product for

the specific legislative or environmental demands regarding

the noise emission control.

Page 216: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

216 RC GROUP SpA • General Catalogue• 155.EN.0504

REVERSO.RECIP.C.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

142.F2 188.F2 220.F2G8 G8 G8

126,8 165,9 195,9145,8 192,6 226

2 2 22 2 2

5170 5170 51701290 1290 12902050 2050 20502140 2345 252560 61 67

Heat pump liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

REVERSO.RECIP.C.P.ELN “G”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating

compressors and centrifugal fans. Casing type: ”G”.

IDEN

TIFIC

ATIO

N

The highest energy saving, the lowest noise emission and the possibility of INDOOR installation in a unique product.

Thanks to REVERSO CENTRI version it is possible to take advantage from IDEA dynamic defrosting system even in those

situations where it is necessary to install the chiller in dedicated areas or there is the need of additional acoustic

restraint systems (barriers) to achieved imposed acoustic parameters.

All is managed by PROACTIVE logic characterising all RC microprocessor controls range.

Page 217: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

217RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Part-Winding compressors •

starting system

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

REVERSO.RECIP.C.P.ELN “G”R407C • 130 ÷ 200 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Easy@ServeAll components are accessible through frontal

panels, without removal of heavy noise deading

boxes.

HIGH

LIGHT

S

PumpStationA complete built-in pumping station (without size increase),

equipped with instruments and safety devices totally integrated

with the unit control system in order to emphasize RC PROACTIVE

working.

Page 218: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

218 RC GROUP SpA • General Catalogue• 155.EN.0504

RC GROUP liquid chillers: wide range of units in terms of models, compressors and refrigerants.

MULTIFUNCTION CHILLERSThese chillers are specifically designed for 4 pipe air conditioning systems, where the simultaneous production of hot water andchilled water is requested. They claim a total reliability thanks to the experience acquired during more than 10 years and thanks

to hundred of installations both in Italy and abroad.The units are available both with axial and centrifugal fans.

ELN RANGE (EXTREMELY LOW NOISE)For over 20 years RC Group has offered a standard catalogued range of units designed specifically to provide the "lowest noiseemission" equipment on the market.The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and reducing theserviceability of the equipment but instead has concentrated on removing the sound emissions at "source".By careful selection of matched components and innovative design of the condensing coil surface and airflow distribution, the ELN rangehas evolved into one of the quietest and thermally efficient Packaged Chillers in today's market place.This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy noise reductionkits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike that of the materials of the"bolt-on" sound reduction kits that can decay over time.All RC Group chillers are available in the ELN range, including versions with axial or centrifugal fans.

PLAN

T TY

PEMultifunction air cooledliquid chillers

Page 219: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

219RC GROUP SpA • General Catalogue• 155.EN.0504

Multifunction air cooledliquid chillers

MULTIPLO.SCROLL.A.STD “G” • R407C • 60 ÷ 115 kWMultifunction liquid chillers with scroll compressors.

MULTIPLO.SCROLL.A.ELN “G” • R407C • 60 ÷ 115 kWExtremely low noise multifunction liquid chillers with scroll

compressors.

MULTIPO.RECIP.A.STD “G” • R407C • 130 ÷ 282 kWMultifunction liquid chillers with reciprocating compressors.

MULTIPLO.RECIP.A.ELN “G” • R407C • 120 ÷ 282 kWExtremely low noise multifunction liquid chillers with reciprocating

compressors.

MULTIPLO.SCROLL.C.STD “G” • R407C • 57 ÷ 115 kWMultifunction liquid chillers with scroll compressors.

MULTIPLO.SCROLL.C.ELN “G” • R407C • 55 ÷ 115 kWExtremely low noise multifunction liquid chillers with scroll compressors.

MULTIPLO.RECIP.C.STD “G” • R407C • 128 ÷ 282 kWMultifunction liquid chillers with reciprocating compressors.

MULTIPLO.RECIP.C.ELN “G” • R407C • 121 ÷ 282 kWExtremely low noise multifunction liquid chillers with reciprocating

compressors.

220 AXIAL FANS

222

224

226

228 CENTRIFUGAL FANS

230

232

234

INDE

X

Page 220: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

220 RC GROUP SpA • General Catalogue• 155.EN.0504

MULTIPLO.SCROLL.A.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

64.Z2 74.Z2 100.Z2 124.Z2G6 G6 G8B G8B

62,1 69,6 93,7 109,174,3 84,1 112,1 132,559,5 69,4 94,6 114,981,5 94,5 129,7 158,9

2 2 2 22 2 2 2

3600 3600 5170 51701290 1290 1290 12901690 1690 1730 17301060 1160 1485 153564 64 64 64

(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Multifunction liquid chillers with axial fansTE

CHNI

CAL D

ATA

MULTIPLO.SCROLL.A.P.STD “G”Multifunction air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.

Casing type: ”G”.

IDEN

TIFIC

ATIO

N

MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water for “comfort” and

industrial applications in every climatic area. It is recommended for Hotels, Health Centres, Hospitals and all

installations where the simultaneous production of chilled and hot water is required all year long.

As for REVERSO units, also MULTIPLO units are equipped with IDEA, RC Group “patented” defrost system with dynamic

reading of the working parameters. Thanks to proprietary software, IDEA senses the real presence of brine on the

coil, granting defrosting cycles limited to the real working conditions to bring a high energy saving (more than 20-30%

on the average) and a higher working continuity.

Page 221: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

221RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

Pumping group with 1 or 2 pumps •

Chilled water tank •

Hot water tank •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MULTIPLO.SCROLL.A.STD “G”R407C • 60 ÷ 115 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ScrollThe state of the art technology in the field of medium/small size

compressors to grant excellent performances even in medium/

small plants.

SCROLL compressors grant a high reliability rate (MTBF), which

is an essential requirement in plants with continuous working (12

months a year) and it is specific of MULTIPLO applications.

HIGH

LIGHT

S

MateMATE integrated control system for a stepless speed modulation of

condensers fans.

Page 222: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

222 RC GROUP SpA • General Catalogue• 155.EN.0504

MULTIPLO.SCROLL.A.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

64.Z2 74.Z2 100.Z2 124.Z2G6 G6 G8B G8B

56,8 63,6 87,6 107,170,3 80,1 108 13459,5 69,4 94,6 114,981,5 94,5 129,7 158,9

2 2 2 22 2 2 2

3600 3600 5170 51701290 1290 1290 12901690 1690 1730 17301060 1160 1485 153554 56 56 57

(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Multifunction liquid chillers with axial fansTE

CHNI

CAL D

ATA

MULTIPLO.SCROLL.A.P.ELN “G”Multifunction air cooled packaged liquid chillers in extremely low noise equipped with Scroll compressors

and axial fans. Casing type: ”G”.

IDEN

TIFIC

ATIO

N

MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water for “comfort” and

industrial applications in every climatic area.

This series represents the ELN (Extremely Low Noise) range of this particular product.

This product being particularly suitable for Hospitals, Health Centres and Hotels needs, ELN version represents the perfect

solution to respect the requested acoustic parameters (often requested by law) for this kind of applications. RC ELN design

keeps the easy installation and maintenance characteristics of the product, granting an acoustic and cooling performances

durability in time.

Page 223: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

223RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

Pumping group with 1 or 2 pumps •

Chilled water tank •

Hot water tank •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MULTIPLO.SCROLL.A.ELN “G”R407C • 60 ÷ 115 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Easy@ServeAll components are accessible through frontal panels, without

removal of heavy noise reduction boxes.HIGH

LIGHT

S

QuickStartWhatever is needed for a correct unit working is built-in.

Electrical and water connections only are needed at start-up for

a complete installation in full compliance with all the current

norms.

Page 224: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

224 RC GROUP SpA • General Catalogue• 155.EN.0504

MULTIPLO.RECIP.A.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

142.F2 188.F2 220.F2 260.F2 300.F2G8B G8 G8 G8 G8

128,9 167,6 194 236,3 261,7148,5 195,8 229,2 270,9 305,1136,3 172,4 203,8 246 282,7180,1 227,7 271,5 323 377,7

2 2 2 2 22 2 2 2 2

5170 5170 5170 5170 51701290 1290 1290 1290 12901730 2280 2280 2280 22801800 1950 2260 2600 265065 65 65 73 73

(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMedium noise pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Multifunction liquid chillers with axial fansTE

CHNI

CAL D

ATA

MULTIPLO.RECIP.A.P.STD “G”Multifunction air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.

Casing type: ”G”.

IDEN

TIFIC

ATIO

N

MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water equipped with high

efficiency reciprocating compressors and condensing section with latest generation axial fans. Multiplo is suitable for those

applications where the simultaneous production of chilled and hot water for distribution through plant with four pipes is

required all year long.

PUMPSTATION system installation (a real built-in station with pumps dedicated to hot and chilled water distribution),

transforms MULTIPLO into an independent and auto-controlled heating station without increase of plant dimensions.

This grants a strong reduction of installation costs limiting it to electrical and hydraulic connections.

Page 225: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

225RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Chilled water tank •

Hot water tank •

Mechanical flow switch •

Part-Winding compressors •

starting system

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MULTIPLO.RECIP.A.STD “G”R407C • 130 ÷ 282 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Made2LastAlso MULTIPLO liquid chillers are designed according to MADE2LAST

logic: flexible capillary pipes to avoid problems deriving from

copper work hardening; antivibration holders under the

compressors to reduce vibration transmission to the housing;

housing in anodized aluminium; galvanized steel sheet parts;

aluminium or stainless steel small parts. A housing designed to last

in time and in any weather condition.

HIGH

LIGHT

S

BufferTankPUMPSTATION system can be

completed with BUFFERTANK

optional, integrated water tank to

increase plant inertia with an

important reduction of

compressors start and stop for

more reliability and operating life.

All without any increase of

footprint.

Page 226: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

226 RC GROUP SpA • General Catalogue• 155.EN.0504

MULTIPLO.RECIP.A.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

142.F2 188.F2 220.F2 260.F2 300.F2G8B G8 G8 G8 G8120 155,3 183,1 222,3 251,6

139,9 184,1 219,3 256,2 295,7136,3 172,4 203,8 246 282,7180,1 227,7 271,5 323 377,7

2 2 2 2 22 2 2 2 2

5170 5170 5170 5170 51701290 1290 1290 1290 12901730 2280 2280 2280 22801800 1950 2260 2600 265057 57 58 65 65

(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Multifunction liquid chillers with axial fansTE

CHNI

CAL D

ATA

MULTIPLO.RECIP.A.P.ELN “G”Multifunction air cooled packaged liquid chillers in extremely low noise version equipped with

reciprocating compressors and axial fans. Casing type: ”G”.

IDEN

TIFIC

ATIO

N

MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water equipped with high

efficiency reciprocating compressors and condensing section with latest generation axial fans.

The ELN (Extremely Low Noise) version of this range grants excellent noise levels, typical of RC ELN logic, keeping one of the

highest easy installation and maintenance characteristic of this field.

All operations are controlled by MP99 microprocessor control system equipped with RC PROACTIVE proprietary logic to

grant continuous operation even in emergency situations.

Page 227: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

227RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Chilled water tank •

Hot water tank •

Mechanical flow switch •

Part-Winding compressors •

starting system

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MULTIPLO.RECIP.A.ELN “G”R407C • 120 ÷ 282 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

AdaptiveRangeA great variety of versions, models and optional to meet many

requirements in hi-tech. applications in Hotels, Health Centres,

Hospitals and all structures requiring a simultaneous production

of chilled or hot water all year long in mild climate areas.

HIGH

LIGHT

S

ServiceFastCompressors, electric board and electronic control system

housed in a technical compartment separated from the air flow to

allow standard maintenance with the unit in operation.

Page 228: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

228 RC GROUP SpA • General Catalogue• 155.EN.0504

MULTIPLO.SCROLL.C.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

64.Z2 74.Z2 100.Z2 124.Z2G7 G7 G8 G8

56,8 65,2 93,7 111,370,3 82,8 112,1 13459,5 69,4 94,6 114,981,5 94,5 129,7 158,9

2 2 2 22 2 2 2

3600 3600 5170 51701290 1290 1290 12902010 2010 2050 20501400 1330 2065 208566 68 65 67

(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Multifunction liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

MULTIPLO.SCROLL.C.P.STD “G”Multifunction air cooled packaged liquid chillers equipped with Scroll compressors and centrifugal fans.

Casing type: ”G”.

IDEN

TIFIC

ATIO

N

CentriMULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water equipped with last

generation SCROLL compressors and CENTRI fan section with centrifugal fans.

The use of centrifugal fans makes this MULTIPLO series suitable also for INDOOR installations.

Indeed CENTRI allows the static pressure supplied by the fan section to conform to the possible pressure drops due to duct

system of condensing air intake and/or expulsion.

Page 229: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

229RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

Pumping group with 1 or 2 pumps •

Chilled water tank •

Hot water tank •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MULTIPLO.SCROLL.C.STD “G”R407C • 57 ÷ 115 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CoolingDensityPlusOptimization internal layout to achieve the best ratio between

footprint and cooling capacity.

HIGH

LIGHT

S

PumpStationA complete built-in pumping station equipped with pumps

for hot and chilled water distribution transforms

MULTIPLO into an independent and auto-controlled

heating/cooling “package” without increasing plant

dimensions.

This solution allows a strong reduction of installation

costs limiting it to a the unit electrical and hydraulic

connections.

Page 230: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

230 RC GROUP SpA • General Catalogue• 155.EN.0504

MULTIPLO.SCROLL.C.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

64.Z2 74.Z2 100.Z2 124.Z2G7 G7 G8 G8

55,1 63,3 87,8 109,369,3 81,6 108 135,459,5 69,4 94,6 114,981,5 94,5 129,7 158,9

2 2 2 22 2 2 2

3600 3600 5170 51701290 1290 1290 12902010 2010 2050 20501400 1330 2065 208564 66 58 62

(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Multifunction liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

MULTIPLO.SCROLL.C.P.ELN “G”Multifunction air cooled packaged liquid chillers in extremely low noise version equipped with Scroll

compressors and centrifugal fans. Casing type: ”G”.

IDEN

TIFIC

ATIO

N

ELN Range (Extremely Low Noise)Over 20 years of experience in sound reduction techniques together with SCROLL technology enable RC Group to grant excellent

sound emission levels for this equipment.

These top sound levels are the result of a specific design philosophy concentrated on removing the sound emissions at "source",

without using "bolt-on" acoustic kits.

The use of the latest generation SCROLL compressors highlights the ELN range of characteristics making plant selection of critical

acoustic systems easy.

Page 231: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

231RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Differential pressure switch •

on water side

Door lock main switch •

Pumping group with 1 or 2 pumps •

Chilled water tank •

Hot water tank •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MULTIPLO.SCROLL.C.ELN “G”R407C • 55 ÷ 115 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

SleepWellProprietary software for

lowest noise emission working

during the night.

Essential requirement for the

respect of acoustic norms in

plants devoted to Hospitals and

Hotels.

HIGH

LIGHT

S

AntirumbleRigid base frame made of a multiple layer structure with high noise

absorption characteristics, to reduce the noise emission from the

bottom of the unit. It is an essential component for all those

installations where the units are installed “raised” from the floor

through weight distribution bars and/or antivibration holders.

Page 232: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

232 RC GROUP SpA • General Catalogue• 155.EN.0504

MULTIPLO.RECIP.C.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

142.F2 188.F2 220.F2 260.F2 300.F2G8 G8 G8 G8 G8

128,1 165,6 193,9 229,1 254,1147,8 194,2 223,4 262,5 296,5136,3 172,4 203,8 246 282,7180,1 227,7 271,5 323 377,7

2 2 2 2 22 2 2 2 2

5170 5170 5170 5170 51701290 1290 1290 1290 12902050 2050 2050 2050 20502310 2480 2570 2960 300069 71 75 76 77

(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Multifunction liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

MULTIPLO.RECIP.C.P.STD “G”Multifunction air cooled packaged liquid chillers equipped with reciprocating compressors and centrifugal

fans. Casing type: ”G”.

IDEN

TIFIC

ATIO

N

MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water

equipped with high efficiency reciprocating compressors and condensing section with centrifugal fans.

Thanks to CENTRI it is now possible to take advantage from MULTIPLO multipurpose flexibility even in

INDOOR or ducted applications.

Indeed CENTRI version allows the MULTIPLO air performances to conform to the plant needs, regarding

pressure drops due to grilles and/or insulation systems and to the need of a duct system for air intake

and/or expulsion.

Page 233: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

233RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Chilled water tank •

Hot water tank •

Mechanical flow switch •

Part-Winding compressors •

starting system

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MULTIPLO.RECIP.C.STD “G”R407C • 128 ÷ 282 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

MyNoiseSolutions range (STD-LNO) conceived to allow the selection

directly from the catalogue of the most suitable product for the

specific legislative or environmental demands regarding the

noise emission control.

HIGH

LIGHT

S

PumpStationA complete built-in pumping station

(without size increase), equipped

with instruments and safety

devices totally integrated with the

unit control system in order to

emphasize RC PROACTIVE working;

possibility to integrate

PumpStation with water tank

without any increase in footprint.

Page 234: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

234 RC GROUP SpA • General Catalogue• 155.EN.0504

MULTIPLO.RECIP.C.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

142.F2 188.F2 220.F2 260.F2 300.F2G8 G8 G8 G8 G8

121,8 156,3 183,5 221,7 250,4141,6 185,8 214,1 254,7 292,7136,3 172,4 203,8 246 282,7180,1 227,7 271,5 323 377,7

2 2 2 2 22 2 2 2 2

5170 5170 5170 5170 51701290 1290 1290 1290 12902050 2050 2050 2050 20502310 2480 2570 2960 300062 64 69 72 74

(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Multifunction liquid chillers with centrifugal fansTE

CHNI

CAL D

ATA

MULTIPLO.RECIP.C.P.ELN “G”Multifunction air cooled packaged liquid chillers in extremely low noise version equipped with

reciprocating compressors and centrifugal fans. Casing type: ”G”.

IDEN

TIFIC

ATIO

N

MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water equipped with high efficiency

reciprocating compressors and condensing section with centrifugal fans.

ELN (Extremely Low Noise) version with the highest energy saving, the lowest noise emission and possibility of INDOOR

installation, all gathered in a single unit.

Thanks to MULTIPLO ELN CENTRI version it is now possible to take advantage from the simultaneous production of hot and chilled

water even in those situations where it is necessary to install the chiller in dedicated areas or there is the need of additional

acoustic restraint systems (barriers) to achieved imposed acoustic parameters.

All is managed by PROACTIVE logic characterising all RC microprocessor controls range.

Page 235: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

235RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Plate gas/water heat exchanger •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Door lock main switch •

Pumping group with 1 or 2 pumps •

Chilled water tank •

Hot water tank •

Mechanical flow switch •

Part-Winding compressors •

starting system

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MULTIPLO.RECIP.C.ELN “G”R407C • 121 ÷ 282 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Easy@ServeAll components are accessible through frontal panels,

without removal of heavy noise deading boxes.

HIGH

LIGHT

S

AntirumbleRigid base frame made of a multiple layer structure with high noise

absorption characteristics, to reduce the noise emission from the

bottom of the unit. It is an essential component for all those

installations where the units are installed “raised” from the floor

through weight distribution bars and/or antivibration holders.

Page 236: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

236 RC GROUP SpA • General Catalogue• 155.EN.0504

RC GROUP liquid chillers: wide range of units in terms of models, compressors and refrigerants.

WATER COOLED LIQUID CHILLERSRC GROUP liquid chillers are equipped with Scroll, reciprocating or screw compressors.Energy efficiency is one of the main feature of all models; the wide range of accessories and versions, exchanger for total or

partial condensing heat reclaim are available, allow multiple applications.The latest generation and high reliability microprocessor control system is equipped with RC PROACTIVE proprietary system suitablefor connection with all main Building Management and Remote Monitoring systems available today on the market.

PLAN

T TY

PEWater cooled liquid chillers

Page 237: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

237RC GROUP SpA • General Catalogue• 155.EN.0504

Water cooledliquid chillers

AQUA.IDROCOMPL.W.NRM.Z1 • R407C • 6 ÷ 18 kWIdrocompl liquid chillers with scroll compressor.

AQUA.IDROCOMPL.W.NRM.Z2 • R407C • 23 ÷ 57 kWIdrocompl liquid chillers with scroll compressors.

COLDPACK.W.NRM • R407C • 50 ÷ 210 kWLiquid chillers with scroll compressors.

FRIGO.SCROLL.W.NRM “G” • R407C • 15 ÷ 137 kWLiquid chillers with scroll compressors.

FRIGO.RECIP.W.NRM “G” • R407C • 150 ÷ 310 kWLiquid chillers with reciprocating compressors.

FRIGO.RECIP.W.NRM “S” • R407C • 232 ÷ 3440 kWLiquid chillers with reciprocating compressors.

FRIGO.SCREW.W.NRM “V” • R407C • 130 ÷ 1403 kWLiquid chillers with screw compressors.

FRIGO.SCREW.W.NRM “V” • R407C • 1397 ÷ 4200 kWLiquid chillers with screw compressors.

238 WATER COOLING

240

242

244

246

248

250

252

INDE

X

Page 238: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

238 RC GROUP SpA • General Catalogue• 155.EN.0504

AQUA.IDROCOMPL.W.NRM.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

AQUA.IDROCOMPL.W.NRM.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

M.7.Z1 M.8.Z1 M.9.Z16,5 7,2 9,11 1 11 1 1

667 667 667497 497 497969 969 969125 125 12548 50 50

T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z17,2 9,1 12,9 15,2 18,11 1 1 1 11 1 1 1 1

667 667 667 667 667497 497 497 497 497969 969 969 969 969125 125 145 150 16050 50 52 52 52

(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”

Water cooled liquid chillersTE

CHNI

CAL D

ATA

AQUA.IDROCOMPL.W.NRM.Z1Water cooled packaged liquid chillers equipped with Scroll compressor, plate condenser and Idrocompl

system.

Water cooled liquid chillers equipped with latest generation SCROLL compressors and IDROCOMPL international

patented integrated system.

IDROCOMPL includes also NOFREEZE working mode, totally protecting from the risks due to water freezing

inside the evaporator.

IDEN

TIFIC

ATIO

N

Page 239: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

239RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of galvanized steel sheet •

externally coated with PVC film

IDROCOMPL system •

Plate condenser •

Microprocessor control system •

Antifreeze system •

Circulating pump •

Water regulating valve •

Remote control board •

RS485 serial line card • OPTI

ONAL

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

AQUA.IDROCOMPL.W.NRM.Z1R407C • 6 ÷ 18 kW

9

8

7

6

55

13

12

11

10

2 31 2 4

1. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger

Idrocompl® System

HIGH

LIGHT

S

Patent

Idrocompl®Patented system including

in a single package the

evaporator, the water

tank and the expansion

tank.

Page 240: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

240 RC GROUP SpA • General Catalogue• 155.EN.0504

AQUA.IDROCOMPL.W.NRM.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

AQUA.IDROCOMPL.W.NRM.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

T.24.Z2 T.28.Z2 T.34.Z2 T.38.Z223 27,6 32,9 37,12 2 2 21 1 1 1

1342 1342 1342 1342497 497 497 497

1340 1340 1340 1340265 275 300 32554 54 54 54

T.42.Z2 T.50.Z2 T.58.Z241,4 49,3 57

2 2 21 1 1

1608 1608 1608708 708 708

1360 1360 1360482 487 50555 55 55

(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N

Water cooled liquid chillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N AQUA.IDROCOMPL.W.NRM.Z2Water cooled packaged liquid chillers equipped with Scroll compressors, plate condenser and Idrocompl

system.

AQUA IDROCOMPL, water cooled liquid chillers equipped with latest generation SCROLL compressors and IDROCOMPL international

patented integrated system.

Thanks to QUICK START design logic, AQUA IDROCOMPL can be considered plug and play units.

For the start-up the units only need electrical and hydraulic connections for a complete installation in compliance with all the

current norms.

Page 241: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

241RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of galvanized steel sheet •

externally coated with PVC film

IDROCOMPL system •

Plate condenser •

Microprocessor control system •

Antifreeze system •

Circulating pump •

Water regulating valve •

Remote control board •

RS485 serial line card •

Spring antivibration holders •

Main switch •

OPTI

ONAL

AQUA.IDROCOMPL.W.NRM.Z2R407C • 23 ÷ 57 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

SpaceSaverSPACE SAVER, components

internal layout allows all

inspection and maintenance

operations from the front of

the unit, with no use of side

spaces.

HIGH

LIGHT

S

Pump&PressureBuilt-in circulating pump with hydraulic plant pressure control,

all is managed by central microprocessor system.

Page 242: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

242 RC GROUP SpA • General Catalogue• 155.EN.0504

COLDPAK.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

COLDPAK.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

T.50.Z2 T.55.Z2 T.68.Z2 T.84.Z249,2 56,6 72,8 85,4

2 2 2 21 1 1 1

695 695 695 6951200 1200 1200 12001500 1500 1500 1500465 465 490 61559 60 61 61

T.100.Z2 T.125.Z2 T.150.Z3 T.185.Z3112,5 138,4 170,2 208,9

2 2 3 31 1 1 1

795 795 895 8951200 1200 1800 18001700 1700 1700 1700720 740 990 102062 62,5 63,5 64

(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N

Water cooled liquid chillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N COLDPACK.W.NRMWater cooled packaged liquid chillers equipped with Scroll compressors and plate condenser.

COLDPACK, water cooled liquid chillers equipped with latest generation SCROLL compressors.

The use of SCROLL compressors in parallel connection allows increased energy efficiency in partial load operation,

representing approx. 70% of working hours of a liquid chiller in CRITICAL APPLICATION and 30% of the hours of a liquid

chiller in COMFORT applications.

Page 243: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

243RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of galvanized steel sheet •

externally coated with PVC film

Plate evaporator •

Plate condenser •

Microprocessor control system •

Antifreeze system •

Water flow control •

Pump-Down stop •

Door lock main switch •

Water regulating valve •

Remote control board •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

COLDPACK.W.NRMR407C • 50 ÷ 210 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CoolingDensityPlusOptimization system of internal layout to achieve the best

ratio between occupied space and cooling capacity.HIGH

LIGHT

S

MP.ComThe new generation of RC microprocessors with AUTOADAPTIVE logic.

Self-adapting in real time to the actual operating parameters of the

system: such as water flow, plant inertia, outdoor air temperature

and presence of antifreeze solutions in the plant.

Page 244: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

244 RC GROUP SpA • General Catalogue• 155.EN.0504

FRIGO.SCROLL.W.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

FRIGO.SCROLL.W.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

15.Z1 22.Z1 29.Z1 36.Z1 43.Z1 52.Z1 60.Z1 70.Z1G1 G1 G1 G1 G1 G1 G1 G1

15,2 22,1 31,4 37,2 43,6 52,3 57,6 68,81 1 1 1 1 1 1 11 1 1 1 1 1 1 1

620 620 620 620 620 620 620 620825 825 825 825 825 825 825 825

1400 1400 1400 1400 1400 1400 1400 1400200 200 240 240 260 260 300 30059 58 58 59 59 60 60 61

44.Z2 58.Z2 72.Z2 86.Z2 104.Z2 120.Z2 140.Z2G2 G2 G2 G2 G2 G2 G2

44,2 62,8 74,5 87,2 104,7 115,2 137,62 2 2 2 2 2 22 2 2 2 2 2 2

1200 1200 1200 1200 1200 1200 1200825 825 825 825 825 825 825

1400 1400 1400 1400 1400 1400 1400380 460 460 520 520 580 58060 60 61 61 62 62 63

(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N

Water cooled liquid chillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N FRIGO.SCROLL.W.NRM “G”Water cooled packaged liquid chillers equipped with Scroll compressors and plate condenser.

Reference size: “G”.

FRIGO, water cooled liquid chillers equipped with latest generation SCROLL compressors and plate heat exchangers.

All components are housed in a cabinet for reduced noise emission according to all strict current field norms.

The built-in SPACE SAVER function guarantees the possibility to carry out all inspection and maintenance operations from the

front of the unit, thus allowing the side by side installation of more units with high savings of occupied space.

Page 245: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

245RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Plate evaporator •

Plate condenser •

Microprocessor control system •

Pump-Down stop •

Door lock main switch •

Water regulating valve •

Partial heat reclaim •

Mechanical flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

FRIGO.SCROLL.W.NRM “G”R407C • 15 ÷ 137 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ScrollThe state of the art in the field of medium/small size

compressors to grant excellent performances even in medium/

small plants.

SCROLL compressors grant a high reliability rate (MTBF),

which is an essential requirement for units dedicated to

industrial processes or CRITICAL applications.

HIGH

LIGHT

S

TR88Supervision and remote control system; up to 8 FRIGO can be supervised

in installations with fixed and variable flow rate.

Version available with R134a refrigerant chargesee page 274

Page 246: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

246 RC GROUP SpA • General Catalogue• 155.EN.0504

FRIGO.RECIP.W.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

160.F2 204.F2 240.F2 286.F2 332.F2G3 G3 G4 G4 G4

151,5 193 226,1 269,2 3102 2 2 2 22 2 2 2 2

2700 2700 2900 2900 2900850 850 850 850 8501300 1300 1500 1500 15001130 1230 1500 1740 198082,5 79,5 83 83,4 86,5

(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N

Water cooled liquid chillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N FRIGO.RECIP.W.NRM “G”Water cooled packaged liquid chillers equipped with reciprocating compressors and shell and

tube condenser. Reference size: “G”.

FRIGO, water cooled liquid chillers equipped with high efficiency reciprocating compressors and cleanable shell and tube

heat exchangers.

The unit is designed around a frame allowing extraordinary maintenance operations, as for example the heat exchangers

or compressors change in an easy and fast way avoiding any dangerous operation for the unit. Everything is based on

EASY@SERVE logic, characteristic for all RC products range.

Page 247: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

247RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of epoxy painted •

galvanized steel sheet

Shell and tube evaporator •

Shell and tube condenser •

Microprocessor control system •

Pump-Down stop •

One capacity step each compressor •

Door lock main switch •

Water regulating valve •

Partial heat reclaim •

Part-Winding compressors •

starting system

Mechanical or electronic flow switch •

Rubber antivibration holders •

Compressors noise absorption cabinet •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

FRIGO.RECIP.W.NRM “G”R407C • 150 ÷ 310 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

MP99MP99 microprocessor control

system, with RC PROACTIVE

proprietary logic granting

continuous and safe operation in

any condition.

HIGH

LIGHT

S

FullHeatReclaim (FHR)All FRIGO models can be equipped with FULLHEATRECLAIM (FHR)

system for a total condensing heat reclaim, allowing

simultaneous production of chilled and hot water.

Version available with R134a refrigerant chargesee page 274

Page 248: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

248 RC GROUP SpA • General Catalogue• 155.EN.0504

FRIGO.RECIP.W.NRM “S” - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

FRIGO.RECIP.W.NRM “S” - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

245.S1 370.S1 490.S1 640.S1 370.S2 430.S2 490.S2 550.S2 610.S2 675.S2 740.S2 860.S2 980.S2 1100.S2 1220.S2226,7 333,8 436 577,8 344,1 399,1 452 516,2 572,7 628,5 679,2 803,9 913,8 1042,4 1152,3

1 1 1 1 2 2 2 2 2 2 2 2 2 2 21 1 1 1 2 2 2 2 2 2 2 2 2 2 2

3000 3000 3000 3000 3550 3550 3550 3550 3550 3550 3550 3550 3550 3700 37001100 1100 1100 1100 1000 1000 1000 1000 1000 1000 1000 1300 1300 1300 13001980 1980 1980 1980 1850 1850 1850 1850 1850 1850 1850 2000 2000 2000 20001767 1910 2330 2518 2530 2700 2750 2880 2980 3100 3120 3480 3720 3900 400083 85 86 86 85 86 86 87 87 88 88 89 89 89 89

1350.S3 1470.S3 1590.S3 1710.S3 1830.S3 1960.S4 2080.S4 2200.S4 2320.S4 2440.S4 2940.S6 3180.S6 3420.S6 3660.S61254,5 1359,6 1500,1 1611 1718,8 1827,7 1955,5 2066,4 2196,9 2304,5 2719,2 3000,1 3222 3437,7

3 3 3 3 3 4 4 4 4 4 6 6 6 63 3 3 3 3 4 4 4 4 4 6 6 6 6

4890 4890 4890 4890 4890 3550 3550 3550 3700 3700 4890 4890 4890 48901430 1430 1550 1550 1550 2360 2360 2360 2360 2360 3100 3220 3220 32202150 2150 2000 2000 2000 1850 1850 1850 1850 1850 2150 2000 2000 21505200 5230 5520 5560 5600 7900 8100 8250 8350 8500 11520 12100 12390 1267090 90 90 90 90 91 91 91 91 91 91 91 92 92

(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50

Water cooled liquid chillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N FRIGO.RECIP.W.NRM “S”Water cooled packaged liquid chillers equipped with reciprocating compressors and shell and

tube condenser. Reference size: “S”.

FRIGO, water cooled liquid chillers equipped with industrial reciprocating compressors and cleanable shell and tube heat

exchangers.

The unit is designed for heavy duty service as process cooling in food industry, for example the fitted compressors are

designed and manufactured by RC Group. Some basic components like valves, are covered by international patents and are

specific for the latest generation of refrigerants and synthetic oils.

Page 249: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

249RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSStructure in high thickness galvanized •

steel sheet protected with epoxy paint

Shell and tube evaporator •

Shell and tube condensers •

Microprocessor control system •

Pump-Down stop •

Part-Winding compressors •

starting system

One capacity step each compressor •

Door lock main switch •

Water regulating valve •

Partial heat reclaim •

Mechanical or electronic flow switch •

Rubber antivibration holders •

Compressors noise absorption cabinet •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

FRIGO.RECIP.W.NRM “S”R407C • 232 ÷ 3440 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

EMCAll RC products are in

compliance with the

norms about

electromagnetic

compatibility.

HIGH

LIGHT

S

CoolingDensityPlusOptimization of internal layout to achieve the best ratio between

footprint and cooling capacity.

Version available with R134a refrigerant chargesee page 274

Page 250: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

250 RC GROUP SpA • General Catalogue• 155.EN.0504

FRIGO.SCREW.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

FRIGO.SCREW.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

130.V1 160.V1 180.V1 210.V1 240.V1 290.V1 360.V1 420.V1 470.V1 530.V1 580.V1 620.V1 680.V1130 163,2 178,9 202,7 241,6 291,2 351,9 413,4 464,2 513,6 571,8 609,5 703,91 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1

2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150900 900 900 900 900 900 900 900 900 900 900 900 9001950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950

79 79 79 79 80 80 80 80 81 81 81 82 82

260.V2 320.V2 360.V2 420.V2 480.V2 580.V2 720.V2 840.V2 940.V2 1060.V2 1160.V2 1240.V2 1360.V2258,1 326,4 357,7 404,6 481,5 582,6 704 826,9 935 1035,1 1144,5 1219,6 1403

2 2 2 2 2 2 2 2 2 2 2 2 22 2 2 2 2 2 2 2 2 2 2 2 2

3550 3550 3550 3550 3550 3550 3550 3550 3550 3550 3550 3550 35501000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 10001850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850

82 82 83 83 83 84 84 85 85 85 85 85 85

(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50

Water cooled liquid chillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N FRIGO.SCREW.W.NRMWater cooled packaged liquid chillers equipped with screw compressors and shell and tube

condenser.

FRIGO, water cooled liquid chillers equipped with screw compressors and cleanable shell and tube heat exchangers.

Units are equipped with MP99 microprocessor system with RC PROACTIVE proprietary logic to grant working continuity

even in emergency situations.

Page 251: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

251RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSStructure in high thickness galvanized •

steel sheet protected with epoxy paint

Shell and tube evaporator •

Shell and tube condensers •

Microprocessor control system •

Pump-Down stop •

Star/Delta Starters compressors •

One capacity step each compressor •

Door lock main switch •

Water regulating valve •

Partial heat reclaim •

Mechanical or electronic flow switch •

Rubber antivibration holders •

Compressors noise absorption cabinet •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

FRIGO.SCREW.W.NRM “V”R407C • 130 ÷ 1403 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

ScrewHelical twin screw compressors with high efficiency, possibility

of proportional or multistep setting.HIGH

LIGHT

S

FullHeatReclaim (FHR)Integrated system for a total

condensing heat reclaim

allowing simultaneous

production of chilled and hot

water.

Version available with R134a refrigerant chargesee page 274

Page 252: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

252 RC GROUP SpA • General Catalogue• 155.EN.0504

FRIGO.SCREW.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

FRIGO.SCREW.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

1410.V3 1590.V3 1740.V3 1860.V3 2040.V31397,7 1559,1 1724,7 1830,5 2100,2

3 3 3 3 33 3 3 3 3

4890 4890 4890 4890 48901430 1430 1430 1430 14302150 2150 2150 2150 2150

87 87 87 87 87

2220.V4 2320.V4 2480.V4 2720.V4 3180.V6 3480.V6 3700.V6 4080.V62070,2 2289,1 2439,2 2806 3118,5 34490,5 3661 4200,5

4 4 4 4 6 6 6 64 4 4 4 6 6 6 6

3550 3550 3550 3550 4890 4890 4890 48902360 2360 2360 2360 3200 3200 3200 32001850 1850 1850 1850 2150 2150 2150 2150

85 85 85 85 87 87 87 87

(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50

Water cooled liquid chillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N FRIGO.SCREW.W.NRMWater cooled packaged liquid chillers equipped with screw compressors and shell and tube

condenser.

FRIGO, water cooled liquid chillers equipped with screw compressors and cleanable shell and tube heat exchangers.

SCREW compressors and special NOISEBOX use allows the installation of the units in areas with a very strict noise

requirements.

NOISEBOX is designed to grant easy inspection of compressors.

Page 253: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

253RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSStructure in high thickness galvanized •

steel sheet protected with epoxy paint

Shell and tube evaporator •

Shell and tube condensers •

Microprocessor control system •

Pump-Down stop •

Star/Delta Starters compressors •

One capacity step each compressor •

Door lock main switch •

Water regulating valve •

Partial heat reclaim •

Mechanical or electronic flow switch •

Rubber antivibration holders •

Compressors noise absorption cabinet •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

FRIGO.SCREW.W.NRM “V”R407C • 1397 ÷ 4200 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

AdaptiveRangeA wide range of models, versions and optional extras for any

kind of duty service applications in hi-tech. and comfort air

conditioning and industrial process cooling.

HIGH

LIGHT

S

CoolingDensityPlusThanks to COOLING DENSITY PLUS system, FRIGO SCREW range

achieves 4.200 kW cooling capacity in only 16 m2 granting a

Cooling Density (kW per m2 of plant space) of 268 kW/m2.

Version available with R134a refrigerant chargesee page 274

Page 254: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

254 RC GROUP SpA • General Catalogue• 155.EN.0504

RC GROUP liquid chillers: wide range of units in terms of models, compressors and refrigerants.

EVAPORATING UNITSThis range of liquid chillers is equipped with Scroll or reciprocating compressors.Energy efficiency is one of the main features of all models; the wide range of accessories and versions allow multiple applications.

The air condensers to be matched are available with axial or centrifugal fans to allow the installation inside buildings with ducted airintake/discharge.The latest generation and high reliability microprocessor control system is equipped with RC PROACTIVE proprietary system and it issuitable for the connection with all main Building Management e Remote Monitoring systems available today on the market.

PLAN

T TY

PEIndoor Condenserless Chillers

Page 255: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

255RC GROUP SpA • General Catalogue• 155.EN.0504

DIVI.IDROCOMPL.A.NRM.Z1 • R407C • 6 ÷ 17 kWIdrocompl condenserless chillers with scroll compressor.

DIVI.IDROCOMPL.A.NRM.Z2 • R407C • 21 ÷ 52 kWIdrocompl condenserless chillers with scroll compressors.

COLDPACK.A.NRM • R407C • 45 ÷ 197 kWCondenserless chillers with scroll compressors.

FRIGO.SCROLL.A.NRM “G” • R407C • 13 ÷ 118 kWCondenserless chillers with scroll compressors.

FRIGO.RECIP.A.NRM “G” • R407C • 132 ÷ 273 kWCondenserless chillers with reciprocating compressors.

FRIGO.RECIP.A.NRM “S” • R407C • 205 ÷ 3040 kWCondenserless chillers with reciprocating compressors.

256 INDOOR CONDENSERLESS CHILLERS

258

260

262

264

266

Indoor Condenserless ChillersIN

DEX

Page 256: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

256 RC GROUP SpA • General Catalogue• 155.EN.0504

DIVI.IDROCOMPL.A.NRM.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

DIVI.IDROCOMPL.A.NRM.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

M.7.Z1 M.8.Z1 M.9.Z16,2 6,9 8,71 1 11 1 1

667 667 667497 497 497969 969 969120 120 12548 50 50

T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z17 8,7 12,7 14,9 16,61 1 1 1 11 1 1 1 1

667 667 667 667 667497 497 497 497 497969 969 969 969 969120 125 135 140 15550 50 52 52 52

Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”

Indoor Condenserless ChillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N DIVI.IDROCOMPL.A.NRM.Z1Condenserless chillers equipped with Scroll compressor and Idrocompl system.

Matched to remote air cooled condenser.

NoFreezeAntifreeze system which totally preserves from the risks subsequent to water freezing inside

the evaporator.

Page 257: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

257RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of galvanized steel sheet •

externally coated with PVC film

IDROCOMPL system •

Microprocessor control system •

Rotalock stop valves on •

gas delivery and liquid return

Antifreeze system •

Remote air cooled condenser •

Circulating pump •

Remote control board •

RS485 serial line • OPTI

ONAL

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

DIVI.IDROCOMPL.A.NRM.Z1R407C • 6 ÷ 17 kW

HIGH

LIGHT

S

9

8

7

6

55

13

12

11

10

2 31 2 4

1. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger

Idrocompl® system

Patent

Idrocompl®Patented system including evaporator, water tank and

expansion tank in a single component.

Page 258: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

258 RC GROUP SpA • General Catalogue• 155.EN.0504

DIVI.IDROCOMPL.A.NRM.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

DIVI.IDROCOMPL.A.NRM.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

T.24.Z2 T.28.Z2 T.34.Z2 T.38.Z220,9 25,1 29,2 33,9

2 2 2 21 1 1 1

1342 1342 1342 1342497 497 497 497

1340 1340 1340 1340265 275 285 29554 54 54 54

T.42.Z2 T.50.Z2 T.58.Z237,3 46 51,9

2 2 21 1 1

1608 1608 1608708 708 708

1360 1360 1360462 485 49555 55 55

Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N

Indoor Condenserless ChillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N DIVI.IDROCOMPL.A.NRM.Z2Condenserless chillers equipped with Scroll compressors and Idrocompl system.

Matched to remote air cooled condenser.

SpaceSaverBuilt-in SPACE SAVER function grants the possibility to carry out all inspection and maintenance operations from the

front of the unit, allowing the side-by-side installation of more units with a high space saving.

Page 259: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

259RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of galvanized steel sheet •

externally coated with PVC film

IDROCOMPL system •

Microprocessor control system •

Rotalock stop valves on •

gas delivery and liquid return

Antifreeze system •

Remote air cooled condenser •

Circulating pump •

Remote control board •

RS485 serial line •

Rubber antivibration holders •

Main switch •

OPTI

ONAL

DIVI.IDROCOMPL.A.NRM.Z2R407C • 21 ÷ 52 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Made2LastHousing designed to last in time and in any weather condition:

flexible capillary pipes to avoid problems deriving from copper

work hardening; antivibration holders under the compressors to

reduce vibration transmission to the housing; galvanized steel

sheet parts; aluminium or stainless steel small parts.

HIGH

LIGHT

S

Easy@ServeAll components are

accessible through

handy frontal panels.

Page 260: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

260 RC GROUP SpA • General Catalogue• 155.EN.0504

COLDPACK.A.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

COLDPACK.A.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

T.50.Z2 T.55.Z2 T.68.Z2 T.84.Z245,3 52 68 78,1

2 2 2 21 1 1 1

695 695 695 6951200 1200 1200 12001500 1500 1500 1500420 420 445 49059 60 61 61

T.100.Z2 T.125.Z2 T.150.Z3 T.185.Z3105,5 131,1 159,1 196,7

2 2 3 31 1 1 1

795 795 895 8951200 1200 1800 18001700 1700 1700 1700670 680 925 94062 62,5 63,5 64

Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N

Indoor Condenserless ChillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N COLDPACK.A.NRMCondenserless chillers equipped with Scroll compressors.

Matched to remote air cooled condenser.

COLDPACK: condenserless chiller equipped with SCROLL compressors; the most modern technology in the field of medium/

small compressors to grant excellent performances even in small/medium installations.

COLDPACK range is designed according to COOLING DENSITY PLUS logic for internal layout optimization, in order to guarantee

a better ratio between occupied space and supplied cooling capacity.

Page 261: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

261RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of galvanized steel sheet •

externally coated with PVC film

Plate evaporator •

Microprocessor control system •

Antifreeze system •

Water flow control •

Pump-Down stop •

Rotalock stop valves on •

gas delivery and liquid return

Door lock main switch •

Remote air cooled condenser •

Partial or total heat reclaim •

Mechanical flow switch •

Rubber antivibration holders •

RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

COLDPACK.A.NRMR407C • 45 ÷ 197 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

AdaptiveRangeA wide range of models, optional extras and versions for

many applications, in comfort and hi-tech. air conditioning

systems.

HIGH

LIGHT

S

MP.ComThe new generation of RC microprocessors with AUTOADAPTIVE

logic. Self-adapting in real time to the actual operating parameters

of the system: such as water flow, plant inertia, outdoor air

temperature and presence of antifreeze solutions in the plant.

Page 262: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

262 RC GROUP SpA • General Catalogue• 155.EN.0504

FRIGO.SCROLL.A.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

FRIGO.SCROLL.A.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

15.Z1 22.Z1 29.Z1 36.Z1 43.Z1 52.Z1 60.Z1 70.Z1G1 G1 G1 G1 G1 G1 G1 G1

13,3 18,5 26,4 31,8 37,4 42 51,2 59,11 1 1 1 1 1 1 11 1 1 1 1 1 1 1

620 620 620 620 620 620 620 620825 825 825 825 825 825 825 825

1400 1400 1400 1400 1400 1400 1400 1400190 190 230 230 240 240 270 27059 58 58 59 59 60 60 61

44.Z2 58.Z2 72.Z2 86.Z2 104.Z2 120.Z2 140.Z2G2 G2 G2 G2 G2 G2 G2

36,7 52,8 63,6 74,8 84,1 102,4 118,32 2 2 2 2 2 22 2 2 2 2 2 2

1200 1200 1200 1200 1200 1200 1200825 825 825 825 825 825 825

1400 1400 1400 1400 1400 1400 1400370 450 450 490 490 530 53060 60 61 61 62 62 63

Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N

Indoor Condenserless ChillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N FRIGO.SCROLL.A.NRM “G”Condenserless chillers equipped with Scroll compressors.

Matched to remote air cooled condenser.

FRIGO.A, condenserless chiller equipped with latest generation SCROLL compressors and plate heat exchangers. All

components are housed in a cabinet for reduced noise emission according to all strict current field norms.

The built-in SPACE SAVER function guarantees the possibility to carry out all inspection and maintenance operations from the

front of the unit, thus allowing the side by side installation of more units with high savings of occupied space.

Page 263: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

263RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Plate evaporator •

Microprocessor control system •

Pump-Down stop •

Door lock main switch •

Remote air cooled condenser •

Partial or total heat reclaim •

Mechanical flow switch •

Rubber antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

FRIGO.SCROLL.A.NRM “G”R407C • 13 ÷ 118 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

CoolingDensityPlusOptimization of internal layout to achieve the best ratio

between footprint and cooling capacity.HIGH

LIGHT

S

EMCAll RC products are in compliance with the norms about

electromagnetic compatibility.

Version available with R134a refrigerant chargesee page 274

Page 264: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

264 RC GROUP SpA • General Catalogue• 155.EN.0504

FRIGO.RECIP.A.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

160.F2 204.F2 240.F2 286.F2 332.F2G3 G3 G4 G4 G4

132,2 172,2 199,6 241,8 273,12 2 2 2 22 2 2 2 2

2700 2700 2900 2900 2900850 850 850 850 850

1300 1300 1500 1500 15001070 1080 1350 1560 171082,5 79,5 83 83,4 86,5

Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N

Indoor Condenserless ChillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N FRIGO.RECIP.A.NRM “G”Condenserless chillers equipped with reciprocating compressors.

Matched to remote air cooled condenser.

FRIGO.A, Condenserless chiller equipped with high efficiency reciprocating compressors and cleanable shell and tube heat

exchangers.

The unit is designed around a frame allowing extraordinary maintenance operations, as for example the heat exchangers

or compressors change in an easy and fast way avoiding any dangerous operation for the unit. Everything is based on

EASY@SERVE logic, characteristic for all RC products range.

Page 265: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

265RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of epoxy painted •

galvanized steel sheet

Shell and tube evaporator •

Microprocessor control system •

Pump-Down stop •

One capacity step each compressor •

Door lock main switch •

Remote air cooled condenser •

Partial or total heat reclaim •

Part-Winding compressors •

starting system

Mechanical or electric flow switch •

Rubber antivibration holders •

Compressors noise absorption cabinet •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

FRIGO.RECIP.A.NRM “G”R407C • 132 ÷ 273 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

MP99MP99 microprocessor control system, with RC PROACTIVE

proprietary logic granting continuous and safe operation in

any condition.HIGH

LIGHT

S

ZytelThe special compressor discharge pipes made of patented plastic

material avoid the breaking problems due to materials decay

(vibrations) typical of outdated copper pipelines and allow the fast

change of various pressure control components without any

refrigerant leak .

Version available with R134a refrigerant chargesee page 274

Page 266: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

266 RC GROUP SpA • General Catalogue• 155.EN.0504

FRIGO.RECIP.A.RNM “S” - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

FRIGO.RECIP.A.RNM “S” - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (2) dB(A)

245.S1 370.S1 490.S1 640.S1 370.S2 430.S2 490.S2 550.S2 610.S2 675.S2 740.S2 860.S2 980.S2 1100.S2 1220.S2203,9 304,6 409,4 509,4 309,5 361,8 406,6 460,3 508,2 561,8 609,4 718,5 814,4 921,5 1017,4

1 1 1 1 2 2 2 2 2 2 2 2 2 2 21 1 1 1 2 2 2 2 2 2 2 2 2 2 2

3000 3000 3000 3000 3550 3550 3550 3550 3550 3550 3550 3550 3550 3700 37001100 1100 1100 1100 1000 1000 1000 1000 1000 1000 1000 1300 1300 1300 13001980 1980 1980 1980 1850 1850 1850 1850 1850 1850 1850 2000 2000 2000 20001655 1765 2065 2117 2440 2560 2560 2680 2760 2862 2876 3260 3420 3560 364083 85 86 86 85 86 86 87 87 88 88 89 89 89 89

1350.S3 1470.S3 1590.S3 1710.S3 1830.S3 1960.S4 2080.S4 2200.S4 2320.S4 2440.S4 2940.S6 3180.S6 3420.S6 3660.S61120,3 1215,2 1329,5 1425,3 1520,4 1628,7 1736 1831,7 1939,2 2034,8 2430,4 2658,9 2850,6 3040,9

3 3 3 3 3 4 4 4 4 4 6 6 6 63 3 3 3 3 4 4 4 4 4 6 6 6 6

4890 4890 4890 4890 4890 3550 3550 3550 3700 3700 4890 4890 4890 48901430 1430 1550 1550 1550 2360 2360 2360 2360 2360 3100 3220 3220 32202150 2150 2000 2000 2000 1850 1850 1850 1850 1850 2150 2000 2000 21504750 4690 4960 4990 5010 7140 7330 7460 7540 7670 10330 10870 11130 1137090 90 90 90 90 91 91 91 91 91 91 91 92 92

Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N

Indoor Condenserless ChillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N FRIGO.RECIP.A.NRM “S”Condenserless chillers equipped with reciprocating compressors.

Matched to remote air cooled condenser.

FRIGO, Condenserless chiller equipped with industrial reciprocating compressors and cleanable shell and tube heat

exchangers.

The unit is designed for heavy duty service as process cooling in food industry, for example the fitted compressors

are designed and manufactured by RC Group.

Some basic components, like valves, are covered by international patents and are specific for last generation of

refrigerants and synthetic oils.

Page 267: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

267RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSStructure in high thickness galvanized •

steel sheet protected with epoxy paint

Shell and tube evaporator •

Microprocessor control system •

Pump-Down stop •

Part-Winding compressors •

starting system

One capacity step each compressor •

Door lock main switch •

Remote air cooled condenser •

Partial or total heat reclaim •

Mechanical or electric flow switch •

Rubber antivibration holders •

Compressors noise absorption cabinet •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

FRIGO.RECIP.A.NRM “S”R407C • 205 ÷ 3040 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

NoiseBoxNoise reduction system designed to grant the easy and

complete inspection of the compressors and associated

components.HIGH

LIGHT

S

TR88Supervision and remote control

system; up to 8 FRIGO can be

supervised in installation with

constant and variable flow rate.

Version available with R134a refrigerant chargesee page 274

Page 268: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

268 RC GROUP SpA • General Catalogue• 155.EN.0504

RC GROUP liquid chillers: wide range of units in terms of models, compressors and refrigerants.

HEAT PUMP CONDENSERLESS CHILLERSThis range of liquid chillers uses Scroll compressors.All models are characterised by a high efficiency and can be customized thanks to a wide range of optional extras.

The air cooled condensers to be matched are available with axial or centrifugal fans to allow the units installation inside building withducted air intake/discharge.

PLAN

T TY

PEIndoor Heat Pump Condenserless Chillers

Page 269: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

269RC GROUP SpA • General Catalogue• 155.EN.0504

DIVI.IDROCOMPL.A.P.NRM.Z1 • R407C • 6 ÷ 17 kWIdrocompl heat pump condenserless chillers with scroll compressor.

DIVI.IDROCOMPL.A.P.NRM.Z2 • R407C • 21 ÷ 52 kWIdrocompl heat pump condenserless chillers with scroll compressors.

270 HEAT PUMP EVAPORATING UNITS

272

Indoor Heat PumpCondenserless chillers

INDE

X

Page 270: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

270 RC GROUP SpA • General Catalogue• 155.EN.0504

DIVI.IDROCOMPL.A.P.NRM.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

DIVI.IDROCOMPL.A.P.NRM.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

M.7.Z1 M.8.Z1 M.9.Z16,1 6,9 8,67 7,9 10,31 1 11 1 1

667 667 667497 497 497969 969 969123 123 12848 50 50

T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z16,9 8,6 12,5 14,6 16,27,9 10,3 14,3 17 18,61 1 1 1 11 1 1 1 1

667 667 667 667 667497 497 497 497 497969 969 969 969 969123 128 139 144 15950 50 52 52 52

Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Data referred to hot water temperature 40/45°C; air to gas/air heat exchanger 7°C with 90%UR.(3) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”

Indoor Heat Pump Condenserless ChillersTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N DIVI.IDROCOMPL.A.P.NRM.Z1Heat pump condenserless chillers equipped with Scroll compressor and Idrocompl system.

Matched to remote air cooled condenser.

AdaptiveRangeA wide range of models, optional extras and versions for application in hi-tech., hotels,

cinemas and shopping centres air conditioning systems.

Page 271: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

271RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of galvanized steel sheet •

externally coated with PVC film

IDROCOMPL system •

Cycle inversion valve •

Microprocessor control system •

Rotalock stop valves on •

gas delivery and liquid return

Antifreeze system •

Remote air cooled condenser •

Circulating pump •

Remote control board •

RS485 serial line • OPTI

ONAL

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

DIVI.IDROCOMPL.A.P.NRM.Z1R407C • 6 ÷ 17 kW

CoolingDensityPlusOptimization of internal layout to achieve the best

ratio between footprint and cooling capacity.

HIGH

LIGHT

S

Pump&PressurePUMP&PRESSURE kit consists of a built-in circulation pump and

of a water pressure control. Through this kit DIVI.IDROCOMPL.P

becomes a real heating station only needing electrical and

hydraulic connections to be 100% operating respecting all the

current norms.

Page 272: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

272 RC GROUP SpA • General Catalogue• 155.EN.0504

DIVI.IDROCOMPL.A.P.NRM.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

DIVI.IDROCOMPL.A.P.NRM.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgNoise pressure level (3) dB(A)

T.24.Z2 T.28.Z2 T.34.Z2 T.38.Z220,6 24,5 28,4 32,623,5 28,3 33 37,5

2 2 2 21 1 1 1

1342 1342 1342 1342497 497 497 497

1340 1340 1340 1340275 285 295 30554 54 54 54

T.42.Z2 T.50.Z2 T.58.Z236,9 45,3 50,941,9 51,5 57,4

2 2 21 1 1

1608 1608 1608708 708 708

1360 1360 1360477 500 51055 55 55

Indoor Heat Pump Condenserless ChillersTE

CHNI

CAL D

ATA

Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Data referred to hot water temperature 40/45°C; air to gas/air heat exchanger 7°C with 90%UR.(3) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”

IDEN

TIFIC

ATIO

N DIVI.IDROCOMPL.A.P.NRM.Z2Heat pump condenserless chillers equipped with Scroll compressors and Idrocompl system.

Matched to remote air cooled condenser.

DIVI.IDROCOMP.P, heat pump condenserless chillers equipped with latest generation Scroll compressors and IDROCOMPL

integrated patented system.

IDROCOMPL system includes also NOFREEZE system which totally preserves from the risks subsequent to water freezing inside

the evaporator.

Page 273: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

273RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of galvanized steel sheet •

externally coated with PVC film

IDROCOMPL system •

Cycle inversion valve •

Microprocessor control system •

Rotalock stop valves on •

gas delivery and liquid return

Antifreeze system •

Remote air cooled condenser •

Circulating pump •

Remote control board •

RS485 serial line •

Rubber antivibration holders •

Main switch •

OPTI

ONAL

DIVI.IDROCOMPL.A.P.NRM.Z2R407C • 20 ÷ 51 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

Made2LastHousing designed to last in time and in any weather condition: ZYTEL

flexible capillary pipes to avoid problems deriving from copper

work hardening; antivibration holders under the compressors to

reduce vibration transmission to the housing; galvanized steel

sheet parts; aluminium or stainless steel small parts.

HIGH

LIGHT

S

SpaceSaverPossibility to carry out all

inspection and maintenance

operations from the front of the

unit, SPACE SAVER allows units

side-by-side installation with high

savings of space.

Page 274: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

274 RC GROUP SpA • General Catalogue• 155.EN.0504

R134a refrigerant is a HFC (hydrofluorocarbon) gas,

without Clhoride.

It is classified as a green gas with the lowest environmental

impact having an ozone depletion potential (ODP) equals to

zero; moreover it is not toxic, it is not flammable and has a

very low GWP (Greenhouse Warming Potential) index.

R134a is a pure refrigerant gas having characteristics

making it different from all azeotropic mixtures: pressure

and temperature remain unchanged during its status

changes; from liquid status to vapour and vice versa.

Door lock main switch•

It is also classified as low pressure refrigerant gas because

comparing it with R407c, at the same temperature the

pressure is definitively lower. For example at a temperature

of 50°C corresponds a pressure of 13,2 bar for R134a

against 20 bar for R407C.

For the above reasons R134a represents the solution

granting the most proper operation in installations with

high condensing temperatures.

RC GROUP liquid chillers range with R134a refrigerant

charge is very wide in terms of both units types and used

compressors.

In particular SCREW versions are equipped with high

efficiency twin screw compressors, specifically designed

to work with this refrigerant.

RC GROUP R134a liquid chillers have the same manufacturing

characteristics, optional list and microprocessor control

system as R407C units.

Liquid chillers with R134a

Page 275: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

275RC GROUP SpA • General Catalogue• 155.EN.0504

Liquid chillers with R134a

AIR COOLED LIQUID CHILLERS

Axial fans

UNICO.SCROLL.A.STD / ELN

UNICO.RECIP.A.STD / ELN

UNICO.SCREW.A.STD / ELN

MODULO.RECIP.A.STD

Centrifugal fans

UNICO.SCROLL.C.STD / ELN

UNICO.RECIP.C.STD / ELN

FREE-COOLING AIR COOLED LIQUID CHILLERS

Axial fans

MAXIMO.SCROLL.A.STD / ELN

MAXIMO.RECIP.A.STD / ELN

MAXIMO.SCREW.A.STD / ELN

Centrifugal fans

MAXIMO.SCROLL.C.STD / ELN

MAXIMO.RECIP.C.STD / ELN

WATER COOLED LIQUID CHILLERS

FRIGO.SCROLL.W.NRM

FRIGO.RECIP.W.NRM

FRIGO.SCREW.W.NRM

CONDENSERLESS LIQUID CHILLERS

FRIGO.SCROLL.A.NRM

FRIGO.RECIP.A.NRM

FRIGO.SCREW.A.NRM

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

It is important to specify that these chillers components are different

from the ones of R407C units, so, comparing the two same models, you

can notice a different size, in particular with reference to air cooled

units.

For obvious space reasons we did not include the chapter related to

these units in this catalogue.

R134a liquid chillers catalogue is available only in electronic format (PDF)

and you can get it by requesting it to the RC GROUP Commercial Department

or by downloading it from company Internet site www.rcgroup.it.

Page 276: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

276 RC GROUP SpA • General Catalogue• 155.EN.0504

New air cooled liquid chillers equipped with screw compressors.

AIR COOLED LIQUID CHILLERS EQUIPPED WITH SCREW COMPRESSORSAll models show a high energy efficiency and can be customized thanks to a wide range of optional extras including heat exchangersfor total or partial condensing heat reclaim.The latest generation and highly reliable microprocessor control system is equipped with RC PROACTIVE proprietary system and

it is designed to be connected to the main Building Management and Remote Monitoring systems available on the market.

PLAN

T TY

PEAir cooled liquid chillers - R134a

Page 277: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

277RC GROUP SpA • General Catalogue• 155.EN.0504

UNICO.SCREW.A.FLX “U” • R407C • 450 ÷ 1050 kWLiquid chillers with screw compressors.

UNICO.SCREW.A.HEF “M” • R407C • 450 ÷ 1580 kWLiquid chillers with screw compressors.

UNICO.SCREW.A.XTR “U” • R407C • 460 ÷ 1100 kWLiquid chillers with screw compressors.

INDE

XAir cooled liquid chillers - R134a

278 AXIAL FANS

280

282

Page 278: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

278 RC GROUP SpA • General Catalogue• 155.EN.0504

UNICO.SCREW.A.FLX “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

450.V2 545.V2 620.V2 700.V2 780.V3 895.V3 1045.V3U9 U9 U10 U10 U12/11 U12/11 U13/12

452 544,4 620 697,7 780,3 895,3 1047,52 2 2 2 3 3 32 2 2 2 3 3 3

4510 4510 5500 5500 7480 7480 84702130 2130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 2430 24304160 4850 5480 5340 6750 7970 837075 75 76 76 77 77 77

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Air cooled liquid chillers with axial fans - R134aTE

CHNI

CAL D

ATA

UNICO.SCREW.A.FLX “U”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.

Casing type: “U”.

IDEN

TIFIC

ATIO

N

FLX SeriesA range of highly FLeXible air-cooled chillers, to meet the most important requirements typical of modern

plants, with a good quality/price/performance ratio.

Page 279: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

279RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Oil cooling system •

Star/delta compressors starting system •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Condensing control with Inverter •

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCREW.A.FLX “U”R134a • 450 ÷ 1050 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

PumpStationA complete built-in pumping station

(without size increase), equipped

with instruments and safety

devices totally integrated with the

unit control system in order to

emphasize the RC PROACTIVE

system; possibility to integrate

PumpStation with water tank

without any increase in footprint.

Easy@ServAll components are accessible through handy hinged panels equipped

with antiwind lock, without removal of heavy noise deading boxes.

Made2LastHousing designed to last in time and in any weather condition:

flexible capillary pipes to avoid problems deriving from

copper work hardening; antivibration holders under the

compressors to reduce vibration transmission to the

housing; housing in anodized aluminium; galvanized steel

sheet parts; aluminium or stainless steel small parts.

Page 280: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

280 RC GROUP SpA • General Catalogue• 155.EN.0504

UNICO.SCREW.A.HEF “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

UNICO.SCREW.A.HEF “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

450.V2 500.V2 580.V2 630.V2 680.V2 790.V2 860.V3M15 M15 M161 M16 M16 M17 M18450,4 502,2 582,1 628,9 681,8 790,8 863,4

2 2 2 2 2 2 32 2 2 2 2 2 3

3930 3930 5000 5000 5000 6070 74202350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 25104650 4700 5210 5880 6020 6500 731081 81 81 82 82 82 83

930.V3 1000.V3 1160.V3 1260.V4 1360.V4 1480.V4 1580.V4M18 M18 M19 M20 M20 M21 M22934 1001 1159,5 1257,7 1363,6 1474,9 1581,53 3 3 4 4 4 43 3 3 4 4 4 4

7420 7420 8490 9560 9560 10630 117002350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 25108320 8530 9090 11000 11270 11750 1223083 83 84 84 84 84 84

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Air cooled liquid chillers with axial fans - R134aTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N UNICO.SCREW.A.HEF “M”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.

Casing type “M”.

HEF SeriesIf the energy efficiency is your priority, the High EFficiency range has been designed to deliver

optimum values, among the highest available on today market.

Page 281: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

281RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing made of epoxy painted •

galvanized steel sheet

Shell and tube evaporator •

Microprocessor control system •

Step-step condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Oil cooling system •

Star/delta compressors starting system •

Door lock main switch •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Modulating condensing control •

Condensing control with Inverter •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCREW.A.HEF “M”R134a • 450 ÷ 1580 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

ScrewHelical twin screw compressors

with high efficiency, possibility of

proportional or multistep setting,

designed for air cooled chillers

(high condensing temperatures).

FreezeProtectionEvaporator with built-in antifreeze heater and high thickness

insulation, combined with proprietary software for the

automatic start up of the pumping group with direct scanning

from the digital antifreeze sensor.

Page 282: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

282 RC GROUP SpA • General Catalogue• 155.EN.0504

UNICO.SCREW.A.XTR “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

450.V2 545.V2 620.V2 700.V2 780.V3 895.V3 1045.V3U9 U9 U10 U10 U12/11 U12/11 U13/12

452 544,4 620 697,7 780,3 895,3 1047,52 2 2 2 3 3 32 2 2 2 3 3 3

4510 4510 5500 5500 7480 7480 84702130 2130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 2430 24304160 4850 5480 5340 6750 7970 837075 75 76 76 77 77 77

(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Air cooled liquid chillers with axial fans - R134aTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N UNICO.SCREW.A.XTR “U”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.

Casing type “U”.

XTR SeriesThis series has been designed to meet eXTReme requirements. Its sound levels are the lowest in this sector,

and thanks to an excellent efficiency, coupled with continuous operation up to an outside temperature of 56°C,

this series is a reference point in the segment of high-capacity chillers.

Page 283: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

283RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Microprocessor control system •

Modulating condensing control •

Pump-Down stop •

Step-step cooling capacity control •

Oil cooling system •

Star/delta compressors starting system •

Door lock main switch •

Condensing control with Inverter •

Pumping group with 1 or 2 pumps •

Water tank •

Partial or total heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

Outdoor air temperature sensor •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

UNICO.SCREW.A.XTR “U”R134a • 460 ÷ 1100 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

RCProactiveMicroprocessor control and monitoring

system technology owned by RC

PROACTIVE, designed to grant continuity of

work even in emergency situations.

AntirumbleRigid base frame made of a multiple

layer structure with high noise

absorption characteristics, to reduce

the noise emission from the bottom of

the unit.

It is an essential device in all those

installations where the units are

installed ”raised” from the floor

through distribution bars and/or

antivibration holders.

ServiceFastCompressors, electric

board and electronic

control system housed in

a technical compartment

separated from the air

flow to allow standard

maintenance with the unit

in operation.

Page 284: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

284 RC GROUP SpA • General Catalogue• 155.EN.0504

New air cooled liquid chillers equipped with screw compressors.

FREE-COOLING LIQUID CHILLERSLiquid chillers with built-in indirect SRC free-cooling system are specifically designed to reduce energy consumption wherecooling energy is required even in wintertime and mid-season, as required in air conditioning systems for information technology,

communication and industrial cooling.The units are equipped with a combined system to use outdoor air for water free cooling or precooling.Thanks to a proprietary control logic developed by RC through a 30-year experience in production of these chillers, the energy savingachieved through this type of chillers is always the maximum allowed by the outdoor air temperature, without any compromise.These chillers are available also in OPTIMIZER version, internationally patented, able to multiply the energy savings achieved throughindirect free-cooling solutions specially in areas with a temperate climate.

PLAN

T TY

PEAir cooled free-cooling liquid chillers - R134a

Page 285: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

285RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCREW.A.FLX “U” • R407C • 488 ÷ 1130 kWFree-cooling liquid chillers with screw compressors.

MAXIMO.SCREW.A.XTR “U” • R407C • 488 ÷ 1000 kWFree-cooling liquid chillers with screw compressors.

286 AXIAL FANS

288

Air cooled free-coolingliquid chillers - R134a

INDE

X

Page 286: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

286 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCREW.A.FLX “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

440.V2 550.V2 610.V2 690.V2 765.V3 875.V3 1010.V3U9 U10 U10 U11 U12/11 U13/12 U14/13

488,9 617,2 679,6 775,5 855,8 979,4 1136,4290,7 392,7 392,5 493,7 493,4 587,8 688,6

2 2 2 2 3 3 32 2 2 2 3 3 3

4510 5500 5500 6490 7480 8470 94602385 2385 2385 2385 2385 2385 23852430 2430 2430 2430 2430 2430 24305060 6310 6470 7400 8690 9760 1085075 76 76 77 77 77 77

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fans - R134aTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.SCREW.A.FLX “U”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, screw compressors

and axial fans. Casing type: “U”.

Serie FLXA range of highly FLeXible free-cooling chillers, to meet the most important requirements typical of modern

plants, with a good quality/price/performance ratio.

Page 287: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

287RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Star/delta compressors starting system •

Oil cooling system •

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

LNO Kit for about a 6 dB(A) noise •

pressure level reduction

Condensing control with Inverter •

coupled with flooding system

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.SCREW.A.FLX “U”R134a • 488 ÷ 1130 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

GlycolFreeThanks to a system of

exchangers set inside the unit,

the free-cooling circuit is 100%

protected from freezing

problems, while there is no

antifreeze in the building.

CoolingDensityPlusOptimization of internal layout to achieve the best ratio

between footprint and cooling capacity.

Page 288: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

288 RC GROUP SpA • General Catalogue• 155.EN.0504

MAXIMO.SCREW.A.XTR “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (3) dB(A)

465.V2 585.V2 640.V2 725.V2 815.V3 940.V3U10 U11 U11 U12 U14/13 U14/13

488,9 629,4 681,8 779,8 875,6 1006,2330,6 416,9 415,6 495,3 578 580,1

2 2 2 2 3 32 2 2 2 3 3

5500 6490 6490 7480 9460 94602385 2385 2385 2385 2385 23852430 2430 2430 2430 2430 24305600 7020 7110 8200 10260 1045063 64 64 64 65 65

(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N

Free-cooling liquid chillers with axial fans - R134aTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N MAXIMO.SCREW.A.XTR “U”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, screw compressors and

axial fans. Casing type: “U”.

Made2LastHousing designed to last in time and in bad weather: flexible capillary piping to avoid problems deriving from

copper work hardening; antivibration holders under the compressors to reduce vibration transmission to the

housing; electric cables in conduit and metallic cableways; housing in anodized aluminium; galvanized steel sheet

parts; aluminium or stainless steel small parts.

Page 289: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

289RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHousing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Main components housed in a •

technical compartment separated

from the air flow

Shell and tube evaporator •

Free-cooling system •

Microprocessor control system •

Modulating condensing control •

coupled with flooding system

Pump-Down stop •

Star/delta compressors starting system •

Oil cooling system •

Step-step cooling capacity control •

Door lock main switch •

Optimizer system •

Condensing control with Inverter •

coupled with flooding system

Pumping group with 1 or 2 pumps •

Water tank •

Partial heat reclaim •

Mechanical or electronic flow switch •

Spring antivibration holders •

RS232C-RS422-RS485 serial line •

UDT, SQL or ASME VIII Div.1 approvals •

OPTI

ONAL

MAXIMO.SCREW.A.XTR “U”R134a • 488 ÷ 1000 kW

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

HIGH

LIGHT

S

RCProactiveMicroprocessor control and

monitoring system technology owned

by RC PROACTIVE, designed to grant

continuity of work even in emergency

situations.

SolutionMaximo Optimizer, in combination with our Heat Hunter

displacement air-conditioners series, form the Solution

proprietary system to optimise the energy saving in the presence

of variable flow-rate technological plants.

Page 290: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

290 RC GROUP SpA • General Catalogue• 155.EN.0504

Air cooled condensers and dry coolers are specifically designed to work matched with RC GROUP air conditioning units and liquidchillers.They are available with axial or centrifugal fans to allow the installation in buildings with ducted air intake/discharge.The low noise versions offer working conditions with an extremely reduce noise pressure.

PLAN

T TY

PEAir cooled condensers and dry coolers

Page 291: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

291RC GROUP SpA • General Catalogue• 155.EN.0504

Air cooled condensersDry coolers

AIR COOLED CONDENSERS

TEAM.MATE.DX.A • 8 ÷ 158 kWAir cooled condensers for outdoor installation.

TEAM.MATE.DX.A • 200 ÷ 610 kWAir cooled condensers for outdoor installation.

TEAM.MATE.DX.C • 8 ÷ 24 kWAir cooled condensers for indoor installation.

TEAM.MATE.DX.C.ELN • 12 ÷ 140 kWAir cooled condensers for indoor installation.

DRY COOLERS

TEAM.MATE.DC.A • 16 ÷ 113 kWDry coolers for outdoor installation.

TEAM.MATE.DC.A • 140 ÷ 600 kWDry coolers for outdoor installation.

TEAM.MATE.DC.C • 13 ÷ 120 kWDry coolers for indoor installation.

292 AXIAL FANS

294

296 CENTRIFUGAL FANS

298

300 AXIAL FANS

302

304 CENTRIFUGAL FANS

INDE

X

Page 292: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

292 RC GROUP SpA • General Catalogue• 155.EN.0504

TEAM.MATE.DX.A - D - MODELNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

TEAM.MATE.DX.A - L - MODELNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

M.10D M.18D M.22D M.31D M.37D M.50D M.72D M.79D M.88D M.105D M.118D M.145D M.158D10,2 18,1 21,6 30,6 37,3 49,9 72,5 79 87,8 105,3 118,5 145,2 158,4850 850 1150 1350 1350 1550 2500 2500 3580 3580 3580 4660 4660482 482 482 620 620 620 630 630 630 630 630 630 630726 726 726 1026 1026 1026 1135 1135 1135 1135 1135 1135 113531 37 47 95 110 130 155 185 210 230 260 300 34055 57 56 65 65 64,2 67,2 67,2 68,5 68,5 68,5 67,5 67,5

M.10L M.18L M.22L M.31L M.37L M.50L M.72L M.79L M.88L M.105L M.118L M.145L M.158L8,3 13,6 16,5 24,3 28,6 38,8 56 58,9 70,8 82,7 88,3 111,9 118850 850 1150 1350 1350 1550 2500 2500 3580 3580 3580 4660 4660482 482 482 620 620 620 630 630 630 630 630 630 630726 726 726 1026 1026 1026 1135 1135 1135 1135 1135 1135 113531 37 47 95 110 130 155 185 210 230 260 300 340

47,3 49,3 48,3 57,3 57,3 56,5 59,5 59,5 60,8 60,8 60,8 59,8 59,8

(1) Data referred to condenser inlet air at 35°C, condensing temperature 50°C(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50

Air cooled condensers with axial fansTE

CHNI

CAL D

ATA

MyNoiseSolutions range (D or L) conceived to allow the selection directly from the catalogue of the most suitable product for

the specific legislative or environmental demands regarding the noise emission control.

This solution grants a highly valuable product from the energy point of view, with easy maintenance and a durability of

the results in time (noise deading materials decay).

TEAM.MATE.DX.AAir cooled condensers for outdoor installation equipped with axial fans.

IDEN

TIFIC

ATIO

N

Page 293: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

293RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHorizontal air flow •

Housing made of externally epoxy •

painted galvanized steel sheet

RIV1200 speed regulator for •

modulating condensing control

Stop valves on cooling connections •

Supporting legs for vertical •

air flow versionOP

TION

AL

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

TEAM.MATE.DX.A8 ÷ 158 kW

Made2LastHousing suitable for outdoor installation and designed for long

operating life consisting of galvanized steel sheet parts and

aluminium or stainless steel small parts.

MateIntegrated condensing control

system for a stepless speed

modulation of condensers

fans.

HIGH

LIGHT

S

Page 294: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

294 RC GROUP SpA • General Catalogue• 155.EN.0504

Air cooled condensers with axial fansTE

CHNI

CAL D

ATA TEAM.MATE.DX.A.STD - MODEL

Motor connectionNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

TEAM.MATE.DX.A.ELN - MODELMotor connectionNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

T.244D T.244L T.367D T.367L T.489D T.489L T.612D T.612L∆ Y ∆ Y ∆ Y ∆ Y

244,7 201,8 367,1 302,8 489,4 403,7 611,8 504,63240 3240 4740 4740 6240 6240 7740 77402345 2345 2345 2345 2345 2345 2345 23451385 1385 1385 1385 1385 1385 1385 1385740 740 1000 1000 1280 1280 1540 154075,2 69,2 76,5 70,5 75,5 69,5 77,4 71,4

T.244D T.244L T.367D T.367L T.489D T.489L T.612D T.612L∆ Y ∆ Y ∆ Y ∆ Y

209,8 173,2 314,7 259,8 419,5 346,4 524,4 4333240 3240 4740 4740 6240 6240 7740 77402345 2345 2345 2345 2345 2345 2345 23451385 1385 1385 1385 1385 1385 1385 1385740 740 1000 1000 1280 1280 1540 154072,2 66,2 73,5 67,5 72,5 66,5 74,4 68,4

(1) Data referred to condenser inlet air at 35°C, condensing temperature 50°C(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50

TEAM.MATE.DX.AAir cooled condensers for outdoor installation equipped with axial fans.

Made2LastHousing suitable for outdoor installation and designed for long operating life consisting of galvanized steel sheet parts and

aluminium or stainless steel small parts.

IDEN

TIFIC

ATIO

N

Page 295: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

295RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSVertical air flow •

Stainless steel housing •

Stop valves on cooling connections •

One circuit breaker for each fan •

In alternative to circuit breakers •

a control electric box is available

with modulating or step-step

condensing control

OPTI

ONAL

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

TEAM.MATE.DX.A200 ÷ 610 kW

QuickStartPlug and play unit in full compliance with current norms.

Electrical and refrigerant connections only are requested for

start-up.

EMCAll RC products are in

compliance with the

norms about

electromagnetic

compatibility.

HIGH

LIGHT

S

Page 296: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

296 RC GROUP SpA • General Catalogue• 155.EN.0504

TEAM.MATE.DX.C - D - MODELNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

TEAM.MATE.DX.C - L - MODELNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

M.11.D M.14.D M.16.D M.24.D11,2 13,9 15,4 24930 930 930 1270850 850 850 930

9690 690 690 97070 70 75 8563 65 65 63

M.11.L M.14.L M.16.L M.24.L8,7 11 12 18,4930 930 930 1270850 850 850 930

9690 690 690 97070 70 75 85

55,3 58,3 58,3 55,3

(1) Data referred to condenser inlet air at 35°C, condensing temperature 50°C(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50

Air cooled condensers with centrifugal fansTE

CHNI

CAL D

ATA

TEAM.MATE.DX.CAir cooled condensers for indoor installation equipped with centrifugal fans.

IDEN

TIFIC

ATIO

N

CentriCENTRI version, with centrifugal fans for indoor or ducted installation makes this product the ideal

solution for small areas air conditioning where outdoor installation is not possible due to space or

environmental problems.

Page 297: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

297RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHorizontal air flow •

Housing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

RIV1200 speed regulator for •

modulating condensing control

Stop valves on cooling connections •

Vertical air flow •OP

TION

AL

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

TEAM.MATE.DX.C8 ÷ 24 kW

Made2LastHousing suitable for outdoor installation and designed for

long operating life consisting of galvanized steel sheet

parts and aluminium or stainless steel small parts.

HIGH

LIGHT

S

MateIntegrated condensing control

system for a stepless speed

modulation of condensers fans.

Page 298: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

298 RC GROUP SpA • General Catalogue• 155.EN.0504

TEAM.MATE.DX.C.STD - MODELNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

TEAM.MATE.DX.C.ELN - MODELNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

T.15 T.17 T.21 T.31 T.44 T.57 T.82 T.92 T.116 T.14014,3 17 21 31 44,2 57,3 82,5 92,3 116,1 140,9930 930 1050 1270 1550 1850 2200 2200 2700 2700850 850 930 930 1100 1100 1180 1180 1400 1500690 690 820 970 1040 1190 1230 1230 1540 175070 75 85 140 170 295 320 340 460 56066 68 63 70,5 76 72,7 77,2 78,2 81,2 83,2

T.15 T.17 T.21 T.31 T.44 T.57 T.82 T.92 T.116 T.14012,1 14,2 17,7 26 37,4 48,2 70,1 77,7 97,8 119,2930 930 1050 1270 1550 1850 2200 2200 2700 2700850 850 930 930 1100 1100 1180 1180 1400 1500690 690 820 970 1040 1190 1230 1230 1540 175070 75 85 140 170 295 320 340 460 56059 61,5 56 62 67 63,7 69,2 70,2 74,2 76,2

(1) Data referred to condenser inlet air at 35°C, condensing temperature 50°C(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50

Air cooled condensers with centrifugal fansTE

CHNI

CAL D

ATA

IDEN

TIFIC

ATIO

N TEAM.MATE.DX.CAir cooled condensers for indoor installation equipped with centrifugal fans.

AdaptiveRangeA wide range of models, for application in any air conditioning installation.

Page 299: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

299RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHorizontal air flow •

Housing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

Electric box •

Stop valves on cooling connections •

up to T.44 model included

Insulated panels (ELN version) •

Vertical air flow •

Stop valves on cooling connections •

from T.57 model

Modulating condensing control • OPTI

ONAL

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

TEAM.MATE.DX.C12 ÷ 140 kW

MyNoiseSolutions range (STD-ELN) conceived

to allow the selection directly from

the catalogue of the most suitable

product for the specific legislative

or environmental demands

regarding the noise emission

control.

HIGH

LIGHT

S

QuickStartPlug and play unit in full compliance

with current norms. Electrical and

refrigerant connections only are

requested for start-up.

Page 300: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

300 RC GROUP SpA • General Catalogue• 155.EN.0504

TEAM.MATE.DC.A.STD - MODELNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

TEAM.MATE.DC.A.ELN - MODELNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

M.20 M.26 M.36 M.56 M.83 M.11320,4 26,4 35,7 56,1 82,6 113,51350 1350 1550 2500 3580 4660620 620 620 630 630 630

1026 1026 1026 1135 1135 113595 110 130 185 260 34065 65 64,2 67,2 68,5 67,5

M.20 M.26 M.36 M.56 M.83 M.11316,8 21,4 29,1 45,6 67,9 92,31350 1350 1550 2500 3580 4660620 620 620 630 630 630

1026 1026 1026 1135 1135 113595 110 130 185 260 34057 57 55,2 59,2 60,5 59,5

(1) Data referred to inlet water temperature at 45°C; outdoor air temperature 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50

Dry coolers with axial fansTE

CHNI

CAL D

ATA

TEAM.MATE.DC.ADry coolers for outdoor installation equipped with axial fans.

IDEN

TIFIC

ATIO

N

MyNoiseSolutions range conceived to allow the selection directly from the catalogue of the most suitable product for the

specific legislative or environmental demands regarding the noise emission control.

This solution grants a highly valuable product from the energy point of view, with easy maintenance and a durability of

the results in time (noise deading materials decay).

Page 301: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

301RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHorizontal air flow •

Housing made of externally epoxy •

painted galvanized steel sheet

One circuit breaker for each fan •

up to M56 model included

Supporting legs for •

vertical air flow version

One circuit breaker for each fan •

from M83 model OPTI

ONAL

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

TEAM.MATE.DC.A16 ÷ 113 kW

AdaptiveRangeA wide range of models, for application in any air

conditioning installation.

Made2LastHousing suitable for outdoor installation and designed for long

operating life consisting of galvanized steel sheet parts and

aluminium or stainless steel small parts.

HIGH

LIGHT

S

Page 302: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

302 RC GROUP SpA • General Catalogue• 155.EN.0504

TEAM.MATE.DC.A.STD - MODELMotor connectionNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

TEAM.MATE.DC.A.ELN - MODELMotor connectionNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

T.198D T.198L T.294D T.294L T.377D T.377L T.500D T.500L∆ Y ∆ Y ∆ Y ∆ Y

198,4 159,1 293,9 236,1 377 303,9 499,7 400,53315 3315 4815 4815 6315 6315 7815 78152345 2345 2345 2345 2345 2345 2345 23451385 1385 1385 1385 1385 1385 1385 1385840 840 1120 1120 1460 1460 1740 174072 66 74 68 73 67 74 68

T.198D T.198L T.294D T.294L T.377D T.377L T.500D T.500L∆ Y ∆ Y ∆ Y ∆ Y

166 138,2 245,9 205,3 316,8 264,9 418 347,83315 3315 4815 4815 6315 6315 7815 78152345 2345 2345 2345 2345 2345 2345 23451385 1385 1385 1385 1385 1385 1385 1385840 840 1120 1120 1460 1460 1740 174067 61 69 63 68 62 69 63

(1) Data referred to inlet water temperature at 45°C; outdoor air temperature 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50

Dry coolers with axial fansTE

CHNI

CAL D

ATA

TEAM.MATE.DC.ADry coolers for outdoor installation equipped with axial fans.

EMCAll RC products are in compliance with the norms about electromagnetic compatibility.

IDEN

TIFIC

ATIO

N

Page 303: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

303RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSVertical air flow •

Housing in stainless steel •

One circuit breaker for each fan •OP

TION

AL

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

TEAM.MATE.DC.A140 ÷ 500 kW

Made2LastHousing suitable for outdoor installation and

designed for long operating life consisting of

galvanized steel sheet parts and aluminium or

stainless steel small parts.

HIGH

LIGHT

S

FanSpeedIntegrated control system for stepless fans speed modulation.

Page 304: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

304 RC GROUP SpA • General Catalogue• 155.EN.0504

TEAM.MATE.DC.C.STD - MODELNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

TEAM.MATE.DC.C.ELN - MODELNominal capacity (1) kWDimensions Length mm

Depth mmHeight mm

Net weight kgMean sound pressure level (2) dB(A)

T.16 T.23 T.34 T.44 T.63 T.86 T.11916 23,5 34 44,3 63,4 86,7 119,2

1050 1270 1550 1850 2200 2700 2700930 930 1100 1100 1180 1400 1500820 970 1040 1190 1230 1450 175080 135 163 287 310 450 55063 70,5 76 72,7 77,2 81,2 83,2

T.16 T.23 T.34 T.44 T.63 T.86 T.11913,2 19,5 28,2 36,7 53 72,9 99,21050 1270 1550 1850 2200 2700 2700930 930 1100 1000 1180 1400 1500820 970 1040 1190 1230 1450 175080 135 163 287 310 450 55056 62 67 63,7 69,2 74,2 76,2

(1) Data referred to inlet water temperature at 45°C; outdoor air temperature 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50

Dry coolers with centrifugal fansTE

CHNI

CAL D

ATA

CentriCENTRI version, with centrifugal fans for indoor or ducted installation makes this product

the ideal solution for small areas air conditioning where outdoor installation is not possible

due to space or environmental problems.

TEAM.MATE.DC.CDry coolers for indoor installation equipped with centrifugal fans.

IDEN

TIFIC

ATIO

N

Page 305: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

305RC GROUP SpA • General Catalogue• 155.EN.0504

CHAR

ACTE

RIST

ICSHorizontal air flow •

Housing with aluminium profile frame •

with galvanized steel sheet panels

externally coated with PVC film

One circuit breaker for each fan •

up to T34 model included

Vertical air flow •

One circuit breaker for each fan •

from T44 model

OPTI

ONAL

The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.

TEAM.MATE.DC.C13 ÷ 120 kW

AdaptiveRangeA wide range of models, for application in any air conditioning

installation.HIGH

LIGHT

S

Made2LastHousing suitable for outdoor installation and designed for

long operating life consisting of galvanized steel sheet parts

and aluminium or stainless steel small parts.

Page 306: general catalogue - · PDF file4 RC GROUP SpA • General Catalogue • 155.EN.0504 Introduction INFORMATION TECHNOLOGY MOBILE COMMUNICATION TELECOMMUNICATION BANKS & HI - TECH. OFFICES

RC GROUPw w w . r c g r o u p . i t

RC GROUP S.p.A. • Via Roma, 5 • 27010 Valle Salimbene (PV), Italy • e-mail: [email protected] • Tel. +39 (0) 382 433 811 • Fax +39 (0) 382 587 148

GENERAL CATALOGUE .155.GB.0504