generator specification - diesel and gas generator sets

4
Copy Right 2020 @ AGG POWER www.aggpower.com C713E5 INDUSTRIAL RANGE POWERED BY CUMMINS POWER DEFINITION PRPPrime Power is abailanle for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP:The standby power rating is applicable for supplying emergen- cy power in variable load applications in accordance with ISO 8528-1.Overload is not allowed TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25 ° C Air Intlet Temperature, of a barometric pressure of 100 kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table. TERMS OF USE For the generating sets used indoor, where the acoustic pressure levels depends on the installation conditions, it is not possible to specify the ambient noise level in the exploitation and maintenance instructions. You will also find in our exploitation and maintenance instructions a warning concerning the air noise dangers and the need to imple- ment appropriated preventive measures. Generator Specification POWER kVA 650 713 POWER kW r.p.m 520 570 RATED SPEED 1500 STANDARD VOLTAGE V 400/230 AVAILABLE VOLTAGES V 380/220 · 415/240 RATED AT POWER FACTOR Cos Phi 0,8 SERVICE PRP EPS Weight And Dimensions Length(L) Dimension Open Silent mm mm mm Kg L Net Weight Fuel Tank L H W L H W B ISO 9001 BUREAU VERITAS U R E Certification A U V E R I T A S 1 8 2 8 3675 5012 1950 1560 4431 6062 900 1000 2480 2555 WATER-COOLED THREE PHASE 50 Hz 50 HZ DIESEL D DUAL-WALL FUEL TANK OptionalWidth(W) Height(H)

Upload: others

Post on 14-Jan-2022

60 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Generator Specification - Diesel and Gas Generator Sets

Copy Right 2020 @ AGG POWER www.aggpower.com

C713E5 INDUSTRIAL RANGEPOWERED BY CUMMINS

POWER DEFINITIONPRP:Prime Power is abailanle for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1.ESP:The standby power rating is applicable for supplying emergen-cy power in variable load applications in accordance with ISO 8528-1.Overload is not allowed

TERMS OF USEAccording to the standard, the nominal power assigned by the genset is given for 25 ° C Air Intlet Temperature, of a barometric pressure of 100 kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table.

TERMS OF USEFor the generating sets used indoor, where the acoustic pressure levels depends on the installation conditions, it is not possible to specify the ambient noise level in the exploitation and maintenance instructions.You will also find in our exploitation and maintenance instructions a warning concerning the air noise dangers and the need to imple-ment appropriated preventive measures.

Generator Specification

POWER kVA 650 713

POWER kW

r.p.m

520 570

RATED SPEED 1500

STANDARD VOLTAGE V 400/230

AVAILABLE VOLTAGES V 380/220 · 415/240

RATED AT POWER FACTOR Cos Phi 0,8

SERVICE PRP EPS

Weight And DimensionsLength(L)

Dimension Open Silent

mm

mm

mm

Kg

L

Net Weight

Fuel Tank

L

H

W

L

H

W

B

ISO 9001BUREAU VERITAS

UR

E

Certification

A U V ERITA

S

1 8 2 8

3675 5012

19501560

4431 6062

900 1000

2480 2555

WATER-COOLED THREE PHASE 50Hz 50 HZ DIESEL D DUAL-WALL FUEL TANK (Optional)

Width(W)

Height(H)

Page 2: Generator Specification - Diesel and Gas Generator Sets

Engine Specifications

Engine brand CUMMINS

Engine ref. QSK19G4

4-stroke dieselEngine type

Governor type ECM

DirectInjection

Aspiration

Number of cylinders and arrangement

Bore and stroke

Displacement

Cooling system

Lube oil consumption with full load

Engine oil capacity

Compression Ratio

Total coolant capacity

Air Filter

Turbocharged and Charge Air Cooled

6-L

159*159

18.9

Water-cooled

mm

L

L

15:1

0.5%-1% of fuel consumption

84.4

L

Type

117

Dry

General Engine Data General Engine Data

Fuel

Consumption @ 100% load ESP

Consumption @ 100% load PRP

Consumption @ 75% load PRP

Consumption @ 50% load PRP

L/H

L/H

L/H

L/H

161.0

145.0

111.0

79.0

Alternator Specifications

Number of phase 3 TBD

AVR (Electronic)

Single bearing

Flexible disc

Standard (Vacuum impregnation)

Power factor (Cos Phi) 0.8

Poles 4

Winding Connections (standard) Star-serie

Insulation H class

IP23Enclosure(according IEC-34-5)

Excitation system

No. of bearings

Voltage regulator

Coupling system

Coating type

Alternator Specifications Alternator Specifications

Diesel engine Dry air filter Water jacked heater (Optional)

Radiator water level sensor (Optional)

Oil heater (Optional)

Heavy duty air filter (Optional)

Radiator with pusher fan

Electronic govornor

Hot parts protection

Moving parts protection

4-stroke cycle

Water-cooled

12V electrical system

Water separator filter

Self-excited and self-regulated

IP23 protection

Alternator pre-heater (Optional)

Winding temp. measuring instrument (Optional)

PMG/AREP/MAUX (Optional)H class insulation

Copy Right 2020 @ AGG POWER www.aggpower.com

C713E5

Page 3: Generator Specification - Diesel and Gas Generator Sets

Application Data

Genset version

Fuel system

Fuel oil specifications

Standard fuel tank capacity (Open) L 900

Diesel

1000Standard fuel tank capacity (Silent) L

Exhaust system

Maximum exhaust temperature

Exhaust gas flow

Maximum allowed back pressure

°C

kPa

516

L/s 2206

5.1

8.5

120

2

24

Air system

Intake air flow

Cooling air flow

L/s 876

L/s TBD

Starting System

This document is not contractual - The AGG company reserves the right to modify any of the characteristics stated in this

document without notice, in a constant effort to improve the quality of its products. *ISO 8528. .

AGG Power gensets are compliant with ISO 9001 and CE standard, which include the following directives:

·2006/42/EC Machinery safety.

·2006/95/EC Low voltage

·EN 60204-1: 2006+A1: 2009, EN ISO 12100: 2010, EN ISO 13849-1: 2008, EN 12601 : 2010

Standard reference ConditionsAmbient conditions of reference according to ISO 8528-1:2018 normative: 1000 mbar, 25ºC, 30% relative humidity.

Weights and dimensions based on standard products. Illustrations may include optional equipment.

Technical data described in this catalogue correspond to the available information at the moment of printing.

Steel chasis Chassis with integrated fuel tank Fuel tank drain plug

Steel residential silencer - 20dbA attenuation

Battery charger

Fuel level gauge

High mechanical strength

Epoxy polyester powder coating

Emergency stop button

Anti-vibration shock absorbers

Trailer type (Optional) Stackable canopy design

Copy Right 2020 @ AGG POWER www.aggpower.com

C713E5

kW

Ah

Starting power

Recommended batter

Number of Batteries

Auxiliary voltage Vdc

Page 4: Generator Specification - Diesel and Gas Generator Sets

Control Panel DataFeatures of the Control Panel

Voltage between phases

Voltage between neutral and phase

Current intensities

Frequency

Apparent power (Kva)

Active power (Kw)

Reactive power (kVAr)

Power factor

Voltage between phases

Emergency stop

Binary inputs

Analog inputs

2x10A Current outputs

I/O Configuration

D+ Function

Speed sensor

Amf/Mrs

GCB/MCB

3ph voltage measurement Gen./Mains

3ph current measurement

kW/kWh/Kva

Engine reading

Engine protection

Alternator protection

Earth current protection

History file

RTC/Battery

PLC

4G

Airgate

ECU CAN

MODBUS

MODBUS IP

SNMP

SNMP TRAPS

RS232

RS485

GSM/GPRS modem

Remote screen

Software for PC

AGG UK | AGG China | AGG USA | AGG UAE

[email protected] | www.aggpower.com

Follow us @facebook.com/aggpowergroup

Follow us @linkedin.com/company/agg-power

Follow us @ AGGPOWER

Copy Right 2020 @ AGG POWER www.aggpower.com

350

3

7/7

Advanced Model (Optional)

Standard: Not Available:Optional:

Basic Model (Standard)

6/6

3

150

C713E5