genevac ht and ez-2 series evaporators ht and ez-2 series evaporators ... hcl or thionyl chloride...

44
G G e e n n e e v v a a c c H H T T a a n n d d E E Z Z - - 2 2 S S e e r r i i e e s s E E v v a a p p o o r r a a t t o o r r s s Options & Accessories Brochure 10-1478 Issue 4-15 September 2009 Additional Sample Holders are available, your Sales Representatives can advise on all additional items, including special order items.

Upload: truongkhanh

Post on 20-Mar-2018

257 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

GGeenneevvaacc HHTT aanndd EEZZ--22 SSeerriieess EEvvaappoorraattoorrss

OOppttiioonnss && AAcccceessssoorriieess BBrroocchhuurree

1100--11447788 IIssssuuee 44--1155

SSeepptteemmbbeerr 22000099

AAddddiittiioonnaall SSaammppllee HHoollddeerrss aarree aavvaaiillaabbllee,, yyoouurr SSaalleess RReepprreesseennttaattiivveess ccaann aaddvviissee oonn aallll aaddddiittiioonnaall iitteemmss,, iinncclluuddiinngg ssppeecciiaall oorrddeerr iitteemmss..

Page 2: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation
Page 3: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Contents Introduction ............................................................................................................... 1

The Range............................................................................................................................ 1 Minimum Order Quantities ................................................................................................... 2 Nomenclature ....................................................................................................................... 2 Heat Transfer........................................................................................................................ 2 Protective Coatings .............................................................................................................. 2 HCl or Thionyl Chloride ........................................................................................................ 2 Glassware Labels................................................................................................................. 3 Sample Capacity .................................................................................................................. 3 Rotors ................................................................................................................................... 3 Special Applications ............................................................................................................. 3 Compatibility with Other Manufacturers ............................................................................... 4 Swing / Holder Type ............................................................................................................. 4

Maintenance .............................................................................................................. 5 Inspection ............................................................................................................................. 5 Cleaning ............................................................................................................................... 5 Tube Breakage..................................................................................................................... 5

Swings........................................................................................................................ 6 Fast-stack ............................................................................................................................. 6 Side-bridge ........................................................................................................................... 6

Tube Holders ............................................................................................................. 7 Tube Holders for Side Bridge Swings .................................................................................. 7 One Piece Tube Holders .................................................................................................... 10

Vial Holders ............................................................................................................. 12 Vial Holders for Side Bridge Swings................................................................................... 12 One Piece Vial Holders ...................................................................................................... 17

Centrifuge ................................................................................................................ 18 Centrifuge Tube Holders .................................................................................................... 18 Microcentrifuge Tube Holders ............................................................................................ 18

Bottle Holders.......................................................................................................... 19 Flask Holders........................................................................................................... 20 Microplate Heat Transfer Plates ............................................................................ 22 Gilson and Waters Fraction Collection Racks ..................................................... 24 Miscellaneous.......................................................................................................... 26

Sample Guard Probes........................................................................................................ 26 Thermal Cushion Accessories............................................................................................ 26

SampleGenie ........................................................................................................... 27 SampleGenie - 60 ml.......................................................................................................... 28 SampleGenie - 125 ml........................................................................................................ 30 SampleGenie - 250 ml........................................................................................................ 32

Thermal Cushion..................................................................................................... 34 Sample Holder Part Number Index ........................................................................ 36 Sample Holder Part Number Cross Reference..................................................... 37 Swing Part Number Cross Reference ................................................................... 37 Amendment Control Form...................................................................................... 38

Page 4: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation
Page 5: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 1

Introduction

Genevac evaporators are designed to combine rapid and safe evaporation with high capacity and a wide variety of sample formats. In order to optimise the evaporation performance achieved it is important to select the correct sample holder for your particular application.

Genevac sample holders are manufactured from solid high grade aluminium to very precise specifications and are mass balanced to ensure smooth running of the evaporator.

This guide will help you make the right choice.

The Range

This guide includes the current range of Genevac sample holders which are coloured bright blue for identification purposes. These sample holders are designed for use in an HT series II system, an EZ-2 series system, or may be used in either.

Due to height and weight limitations, a small number of holders have limited compatibility and are not suitable for use with certain systems. Any holder which is subject to a limitation of compatibility, it is highlighted within this brochure. An example of such a limitation is shown below:

Not for use with EZ-2 MK1

In this instance, the sample holder must not be used in an EZ-2 MK1. The EZ-2 Mk1 can be identified by the large circular window in the chamber lid, EZ-2 mk2 and EZ-2 Mk3 has a solid lid with a small tear drop window.

Blue sample holders are not interchangeable with the older range of holders and swings. To choose the correct new holder, refer to the: Sample Holder Part Number Cross Reference.

Should you require an old design of holder, a holder for use in a Genevac HT series 1 system, or a holder for a tube which is not listed, please contact your local Genevac representative or sales agent.

Page 6: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

2 10-1478 - Issue 4-15 September 2009

Minimum Order Quantities

The minimum order quantity for Genevac sample holders is two, larger orders should be for an even number (paired sets) of holders. This also applies to associated parts such as swings, heat transfer plates, SampleGenie assemblies etc.

Nomenclature

Tube holder A holder which accommodates tubes with rounded ends

Vial Holder A holder which accommodates vials with flat ends

Bottle holder A holder which accommodates bottles with flat ends

Flask holder A holder which accommodates round bottom flasks. Holders for tubes with conical or tapered ends are identified individually.

Heat Transfer

A major factor in determining the speed of evaporation is the rate at which heat can transfer to the sample. Greater heat transfer rates mean faster evaporation.

Here are two ways that Genevac HT series II and EZ-2 series evaporators optimise heat transfer:

• High quality aluminium rotors and holders. Recommended for its properties of high thermal conductivity and low weight, Genevac systems use aluminium sample holders which have particularly efficient heat transfer properties.

• High quality engineering. Genevac samples holders are manufactured to very precise specifications. Tubes fit very snugly into the tube holders as any gaps would slow down the rate of heat transfer. This is why it is important to provide us with a sample of tubes when placing orders for sample holders.

Protective Coatings

Standard aluminium sample holders are Hard Anodised (water sealed) for protection against all normal organic solvents, including strong acids such as TFA, HCl and thionyl chloride.

HCl or Thionyl Chloride

To evaporate HCl or thionyl chloride, it is necessary to purchase a system (comprising of: evaporator, condenser and pump) which is HCl and thionyl chloride resistant. These systems are specifically built to resists attack from HCl and thionyl chloride.

Page 7: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 3

Glassware Labels

There are two common methods of labelling glassware in laboratories; both can cause problems in the evaporator.

Paper or film labels The label effectively increases the tube diameter and the problem is exaggerated if the label overlaps itself. The tube or vial no longer fits snugly into the holder, high spots cause stress in the glass and compromise efficient heat transfer from the holder.

Ceramic Etched Ceramic labels etch the glass and may weaken it. Genevac recommend testing new tubes for breakage before buying large numbers.

Sample Capacity

Genevac uses the latest computer aided design technology to ensure evaporators have maximum internal capacity within a minimal instrument footprint. This means high throughput evaporation is possible from an instrument taking up a small amount of bench top space.

Rotors

For information on Genevac rotors, please refer to the Quick Guide to HT Series Rotors available to download from our web site.

Special Applications

As the market leader in centrifugal evaporation, Genevac have already designed holders for the majority of applications. Please examine the list on the following pages, to find the correct part number.

Should you have a special application or unusual tube size, we can design a special holder for you. Please note there is a nominal charge to cover design time for this service. Our experienced sales team (or international distributors) will be pleased to advise you of the options available.

Page 8: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

4 10-1478 - Issue 4-15 September 2009

Compatibility with Other Manufacturers

Check the Genevac website for guides to compatibility with Radleys and Metler Toledo Autochemistry (Bohdan) products.

Swing / Holder Type

Genevac offers a comprehensive range of sample holders. Some are designed for use with swings, others are one piece holders which fit straight onto the evaporator rotor. In the following sections of this brochure, Sample Holders for Side-bridge Swings are listed separately from One Piece Holder-swings.

One Piece Holder-swing

Sample Holder and Side-bridge Swing

Page 9: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 5

Maintenance

Inspect and clean the sample holders at least monthly. Always dry the sample holders thoroughly after cleaning, never use wet sample holders in a Genevac system.

The following inspection routine is mandatory following tube breakage or solvent spillage.

Inspection

Visually inspect the swings and sample holders and clean off any debris, especially in the sample holder wells. High points, caused by debris, lead to stress in the glassware and may result in breakage.

The most common cause of repeat glassware breakage is a fragment from a previously broken tube. Solvent can stick glass fragments to the holder making it difficult to remove. Any residual solvent or sample material must be cleaned off.

Superficial surface damage (scratches) do not affect the performance of a sample holder. However, if there is any structural damage (if any part of the sample holder is bent or deformed) do not use it. Contact Genevac Service for evaluation.

Repeated use with strong acids is likely to cause colour fading of the sample holder over time. This is normal and does not affect the integrity of the holder.

Cleaning

Loose dirt and debris can be removed using a brush, a compressed-air line may also be used if this is available. Adhered dirt, debris or sample / solvent residue should be cleaned off using methanol or acetone, soak the sample holders if necessary. The sample holders should then be washed in clean water and fully dried before use.

Tube Breakage

The precision design of all Genevac sample holders contributes, not only to their excellent heat transfer properties and superior evaporation performance, it also ensures that tubes have maximum protection from breakage during evaporation. For additional protection against glassware breakage, some flask holders and some tube holders are designed for use with thermal cushions. Thermal cushions are made from a filled polymer with excellent heat transfer and cushioning properties.

Use only borosilicate tubes with a wall thickness greater than 1.2 mm in Genevac evaporators. Do not use old, damaged or scratched glassware. In laboratories where tubes or vials are reused, each tube or vial must be regularly inspected for damage. Discard any scratched or cracked items.

For more information and advice on this subject, please refer to the Genevac document entitled: Safe Loading. This is available to download from our web site.

Page 10: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

6 10-1478 - Issue 4-15 September 2009

Swings

Fast-stack

Description Specification Part number

standard

70-0092

Holds 4 x shallow well microtitre plates Max plate area: 129.0 x 87.0 x 19.0 mm Mass = 523g

HCl 70-0089

Holds 2 x deep well Micro-Tube Cluster Racks Max plate area: 129.0 x 87.0 x 54.0 mm Mass = 580g Not for use with EZ-2mk1

HCl 70-0959

Side-bridge

Description Specification Part number

Holds 1 x Genevac tube or vial holder Or 1 x Radleys GreenHouse Block Max foot-print: 129.0 x 87.0 mm Mass = 380g

HCl

70-0578

Holds 1 x MT Autochem Miniblock Tube length up to 112 mm For use with HT series II systems only

HCl

70-1053

Page 11: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 7

Tube Holders

Tube Holders for Side Bridge Swings

Tube Specification

Quantity Part number

10 mm x 75 mm Limits: Ø 9.8 to 10.3 mm Length 55 to 75 mm

40 10-5000

12 mm x 75 mm Limits: Ø 11.8 to 12.3 mm Length 55 to 75 mm

40 10-5025

12 mm x 100 mm Limits: Ø 11.8 to 12.3 mm Length 75 to 110 mm

40 10-5001

13 mm x 75 mm Limits: Ø 12.8 x 13.3 Length 55 to 75 mm

40 10-5047

13 mm x 100 Limits: Ø 12.8 x 13.3 mm Length 75 to 110

40 10-5002

13.5 mm x 100 mm Limits: Ø 13.3 to 13.8 mm Length 75 to 100 mm

40 10-5003

Page 12: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

8 10-1478 - Issue 4-15 September 2009

Tube Specification Quantity Part number

15 mm x 75 mm Limits: Ø 14.8 to 15.3 mm Length 55 to 75 mm

28 10-5046

15 mm x 100 mm Limits: Ø 14.8 to 15.3 mm Length 75 to 110 mm

28 10-5008

16 mm x 75 mm Limits: Ø 15.8 to 16.3 mm Length 55 to 75 mm

24 10-5048

16 mm x 100 mm Limits: Ø 15.8 to 16.3 mm Length 75 tp 110 mm

24 10-5004

17mm x 85mm Tapered Microwave Limits: Ø 16.3 to 17.3 mm Length 75 to 90 mm

24 10-5042

17mm x 75 to 110mm Straight Microwave Limits: Ø 16.8 mm to 17.3 mm Length 75 to 110 mm

24 10-5005

Page 13: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 9

Tube Specification

Quantity Part number

18 mm x 100 mm Limits: Ø 17.8 to 18.3 mm Length 75 to 110 mm

24 10-5006

24 mm x 100 mm Limits: Ø 23.8 to 24.3 mm Length 75 to 110 mm

12 10-5044

25 mm x 100 mm Limits: Ø 24.8 to 25.3 mm Length 75 mm to 110 mm

12 10-5009

Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s).

Page 14: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10 10-1478 - Issue 4-15 September 2009

One Piece Tube Holders Tube Specification Quantity

Part number

16 mm x 150 mm Limits: Ø 15.8 to 16.3 mm Length 110 to 152 mm

12 10-5020

16.5 mm x 125 mm Limits: Ø 16.3 to 16.8 mm Length 110 to 132 mm

20

10-5050

17 mm x 150 mm Limits: Ø 16.8 to 17.3 mm Length 110 to 152 mm

12 10-5022

17.5 mm x 140 mm Limits: Ø 17.0 to 17.8 mm Length 105 to 142 mm

12 10-5055

18 mm x 150 mm Limits: Ø 17.8 to 18.3 mm Length 110 to 152 mm

12 10-5015

20 mm x 150 mm Limits: Ø 19.8 to 20.3 mm Length 110 to 152 mm

10 10-5023

Page 15: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 11

Tube Specification Quantity

Part number

24 mm x 110 to 150 mm Limits: Ø 28.8 to 24.3 mm Length 110 to 152 mm Radleys Carousel tube 6 and STEM reaction stations

6 10-5026

25 mm x 15 mm Limits: Ø 24.8 to 25.3 mm Length 110 to 152 mm

6 10-5027

27.5 mm x 140 mm Limits: Ø 27.0 to 27.8 mm Length 105 to 142 mm

6 10-5017

40 mm x 100 mm Limits: Ø 39.8 to 40.3 mm Length 90 to 105 mm

5 10-5052

45 mm x 150 mm Limits: Ø 44.8 to 45.8 mm Length 110 to 152 mm

2

10-5064

Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s).

Page 16: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

12 10-1478 - Issue 4-15 September 2009

Vial Holders

Vial Holders for Side Bridge Swings

Vial Specification

Quantity Part number

10 mm x 45 mm Limits: Ø 9.5 to 10.3 mm Length 35 to 45 mm

48 10-5029

11 mm x 35 mm Limits: Ø 10.7 to 11.5 mm Length 30 to 40 mm

48 10-5032

12 mm x 35 mm GC auto-sampler vial Limits: Ø 11.3 to 12.1 mm Length 30 to 40 mm

48 10-5024

13 mm x 50 mm 4 ml crimp top HPLC vial Limits: Ø 12.5 to 13.3 mm Length 30 to 50 mm

40 10-5034

14.5 mm x 45 mm Limits: Ø 14.0 to 14.8 mm Length 35 to 50 mm

24 10-5035

Page 17: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 13

Vial Specification

Quantity Part number

14.5 mm x 65 mm Limits: Ø 14.0 to 14.8 mm Length 55 to 75 mm

24 10-5016

15 mm x 45 mm Limits: Ø 14.3 to 15.1 mm Length 35 to 50 mm

24 10-5037

15 mm x 65 mm Limits: Ø 14.7 to 15.7 mm Length 55 to 75 mm

24 10-5021

15.5 mm x 45 mm Limits: Ø 15.0 to 15.8 mm Length 35 to 50 mm 1 DRAM & 4ml HPLC screw top vial

24 10-5038

16.5 mm x 65 mm Limits: Ø 16.2 to 17.0 mm Length 55 to 75 mm

24 10-5028

16 mm x 100 mm Limits: Ø 15.5 to 16.3 mm Length 75 to 110 mm

24 10-5067

Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s).

Page 18: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

14 10-1478 - Issue 4-15 September 2009

Vial Specification

Quantity Part number

17 mm x 40 mm Limits: Ø 16.3 to 17.1 mm Length 38 to 50 mm

24 10-5007

17 mm x 75 mm 2 dram vial Limits: Ø 16.5 to 17.3 mm Length 55 to 75 mm

24 10-5030

17.5 mm x 45 mm Limits: Ø 17.0 to 17.8 mm Length 40 to 50 mm

24 10-5031

18 mm x 45 mm Limits: Ø 17.7 to 18.5 mm Length 40 to 50 mm

24 10-5033

20 mm x 65 mm Limits: Ø 19.m to 20.3 mm Length 55 to 75 mm

18 10-5036

20.5 mm x 65 mm Limits: Ø 20.2 to 20.8 mm Length 55 to 75 mm

18 10-5040

Page 19: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 15

Vial Specification Quantity Part number

21 mm x 65 mm Limits: Ø 20.5 to 21.3 mm Length 55 to 75 mm

18

10-5039

21.5 mm x 65 mm Limits: Ø 21.1 to 21.8 mm Length 55 to 75 mm

18 10-5041

22.5 mm 50 mm Limits: Ø 22.0 to 22.8 mm Length 38 to 50 mm

12 10-5062

23.5 mm x 54 mm Limits: Ø 23.0 to 23.8 mm Length 55 to 75 mm

12 10-5019

24 mm x 65 mm Limits: Ø 23.7 to 24.5 mm Length 55 to 75 mm

12 10-5014

27.5 mm x 65 mm Limits: Ø 27.0 to 27.8 mm Length 55 to 75 mm 20ml Scintilation Vial

12 10-5013

Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s).

Page 20: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

16 10-1478 - Issue 4-15 September 2009

Vial Specification Quantity Part number

27.5 mm x 100 mm 40 ml scintillation vial Limits: Ø 27.0 to 27.8 mm Length 75 to 110 mm

8 10-5010

34 mm x 110 mm 50 ml Schott Duran tube No 21617 17

6 10-5059

35 mm x 100 mm Limits: Ø 34.5 to 35.8 mm Length 75 to 110 mm

6 10-5068

Page 21: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 17

One Piece Vial Holders

Vial type

Quantity Part number

25 mm x 120 mm Limits: Ø 24.5 to 25.3 mm Length 85 to 122 mm For use with EZ-2 only

70-0924

25 mm x 150 mm Limits: Ø 24.5 to 25.3 mm Length 110 to 152 mm

6 70-1031

27.5 mm x 140 mm Dionex ASE® tube Limits: Ø 27.0 to 27.8 mm Length 105 to 142 mm

6 10-5017

35 mm x 100 mm Limits: Ø 34.5 to 35.8 mm Length 75 to 110 mm

6 10-5068

Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s). ASE® is a registered trademark of Dionex Corporation

Page 22: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

18 10-1478 - Issue 4-15 September 2009

Centrifuge

Centrifuge Tube Holders

Tube type

Quantity Part number

16.5 mm x 110 mm 12° end 10 ml Limits: Ø 16.0 to 16.8 mm Length 95 to 110 mm Requires viton insert

24 10-5065

16.5 mm x 115 mm 30° end 15 ml centrifuge tube Limits: Ø 16.3 to 17.3 mm Length 100 to 120 mm

24 10-5053

29.5 mm x 115 mm 70° end 50 ml centrifuge tube Limits: Ø 28.5 to 29.8 mm Length 100 to 115 mm

10 10-5054

Microcentrifuge Tube Holders

Tube type

Quantity Part number

8 mm x 30 mm 0.5 ml flip cap, without skirt

50 10-5049

10 mm x 40 mm 1.5 ml flip cap, without skirt

32 10-5043

10 mm x 47 mm 2.0 ml flip cap, without skirt

24 10-5011

Page 23: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 19

Bottle Holders

Bottle Specification

Quantity Part number

55.5 mm x 100 mm Schott 100 ml Limits: Ø 54.0 to 56.0 Length 90 to 110 mm

2 70-1025

70 mm x 140 mm Schott 250 ml 400 ml Fisher Beaker No FB33124 Requires Thermal Cushion

1 10-5060

82 mm x 152 mm 500 ml bottle Requires thermal Cushion Not for use with EZ-2 MK 1

1 10-5063

60.5 mm x 125 mm 250 ml Nalge Nunc no 3127-0250

2 10-5061

Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s).

Page 24: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

20 10-1478 - Issue 4-15 September 2009

Flask Holders Flask Specification Quantity

Part number

25ml Socket Size 19/26 – 24/29

6 70-0538

50ml Socket Size 29/32

4 70-0539

50ml Socket size 19/26 to 24/29

4 70-0656

50 ml Socket size 24/29 to 29/32

4 70-1026

100ml Socket size 19/26 to 24/29 Including Radleys 6 Pace Carousel For use with EZ-2 only

3 70-0657

100ml Socket size 29/36 to 19/32 For use with EZ-2 only

3 70-0579

Page 25: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 21

Flask Specification Quantity

Part number

250 ml Socket size 19/22 to 29/32 Including Radleys 6 Place Carousel

1 70-0580

500 ml Socket Size 19/32 to 29/32 For use with EZ-2 Only

1

70-0582

500 ml Socket size 19/32 to 29/21 Max flask height: 156 mm For use with HT series II 0nly

1

10-1616

Note: To prolong glassware lifetime and dramatically reduce sample drying time, these round bottom flask holders must be used with Genevac Thermal Cusion.

Page 26: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

22 10-1478 - Issue 4-15 September 2009

Microplate Heat Transfer Plates

Heat transfer plates are available for use in open swings, side bridge swings, and most Fast Stack holders.

This range of sample holders provide improved evaporation results when using deep well microtitre plates. Heat Transfer Plates are designed to support the wells of the plate, fitting precisely to the base of the wells, and where possible, to the sides of each well.

Heat transfer plates confer three main benefits:

• Excellent heat transfer rates, up to 50% reduced evaporation times when using micro plates.

• Even sample drying

• Support for micro plates when used in open swings, preventing potentially harmful direct heating by lamps, and preventing plate deformation by heat and G-force.

Heat transfer plates must be used when using microtube cluster racks, e.g. Micronics or ABgene racks, in Genevac open swings.

If you would like a micro plate evaluated to see if a suitable Heat Transfer Plate exists, or would like further information, please contact your Genevac representative.

Page 27: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 23

Description Use

Part number

Max foot-print: 128.0 x 86.5 mm Mass = 200 g

For use in

Side-bridge Sswing

70-0086

Ex-Stock

Compatible with: Falcon, Micronic Traxis and Micronic Multi-Tube Cluster Racks Round end tubes

For use in

Side-bridge Swing

70-0084

Special order

Compatible with: Beckman 1 ml x 96 O Beckman 2 ml x 96 Costar 1 ml x 96 O Costar 2 ml x 96 Whatman 2 ml x 96

For use in

Side-bridge Swing

70-0085

Special order

Compatible with: Axygen 2 ml x 96 O Greiner 1 ml x 96 O Nunc 2 ml x 96 O Nunc 1 ml x 96 O Whatman 1 ml x 96 O

For use in

Side-bridge Swing

70-0087

Special order

Compatible with: MultiChem 10 ml x 24 O Polyfiltronics 10 ml x 24 O UniPlates 10 ml x 24 O Whatman 10 ml x 24 O

For use in Deep-well

swing

70-0357

Special order

Compatible with: ABgene Multi-tube Cluster Racks Round end tubes

For use in Deep-well

swing

70-0361

Special order

The items listed above are a small example from the range of heat transfer plates that Genevac can provide. Please contact your sales representative for details.

Page 28: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

24 10-1478 - Issue 4-15 September 2009

Gilson and Waters Fraction Collection Racks

Genevac offer a range of innovative options that help interface fraction collection systems directly to the Genevac HT series evaporator. Currently Gilson 215 and Waters 2767 systems are supported.

To interface with the fraction collections system, Genevac provide a simple sample holder carrier which fits directly on to the fraction collection bed. Genevac sample holders fit into the carrier to make up a complete fraction collection rack. Once fractions are collected, the sample holders can be placed directly into the Genevac evaporator with no need to label, mark or manipulate individual tubes. Sample holders can be marked to indicate their location within the fraction collection rack.

There are a range of options, some use standard sample holders, some use specially designed holders which keep the spacing between tubes uniform, and reduce fraction collector reprogramming. Waters 2767 users will require the adaptor plate when using 16 mm diameter tubes.

Further information, including a technical article discussing these issues in greater detail, is available upon request from your Genevac representative.

Page 29: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 25

Description Use Part number

Holds Qty 4 tube holders (examples: 10-5020 or 10-5027)

Rack for use

with Waters Fraction

Collection

10-1570

Special order

Converts Waters 2767 Sample Manager Rack Bed to hold 3 Racks

Adapter Plate

for rack 10-1570

04-4181

Special order

Converts Waters 2767 Sample Manager Rack Bed To hold 14 MAX SideBridge Holders

Adapter plate

for Side-bridge

Holders

04-4330

Special order

The items listed above are a small example from the range of fraction collector racks that Genevac can provide. Please contact your sales representative for details.

Page 30: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

26 10-1478 - Issue 4-15 September 2009

Miscellaneous

Sample Guard Probes

Description

Specification Part number

SampleGuard Temperature Probe

CH1 & CH2 Short FastStack Swing Solid Holder Length 160 mm

Standard

HCl

70-0163

70-0197

CH2 Medium Length 220 mm

Standard

HCl

70-0168

70-0200

CH2 Long Length 280 mm

Standard

HCl

70-0210

70-0212

Thermal Cushion Accessories Description

Use Part number

Applicator

For use with

Thermal Cushion

04-3822

Ex-Stock

Spatula

For use with

Thermal Cushion

04-3869

Ex-Stock

Page 31: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 27

SampleGenie

Designed for situations where large volumes need to be dried or concentrated into a small vial. SampleGenie™ comprises sample tube and sample holder technology which enables large volume samples to be dried or concentrated directly into a variety of small vials. Where HPLC purification fractions are used, fractions are combined into one tube and and dried or fast lyophilised into the final vial.

Page 32: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

28 10-1478 - Issue 4-15 September 2009

SampleGenie - 60 ml

Assembly Vial Size Quantity Part number

Range: Ø 11.8 to 20.3 mm Length 32 to 50 mm

4 70-1150

The SampleGenie assembly includes Flasks, Holder and black viton Seals. Due to the wide range of options, Adaptors must be specified separately. Alternative seal options (low leachable white viton or highly resistant FFKM perflouroelastomer) may also be specified at point of order.

Subassembly Parts

Description Specification Part number

4 x 60 ml Flask

Borosilicate glass 04-6124 20.5 mm black viton 04-6108 20.5 mm white viton

04-6230

4 x Seal

20.5 mm perflouroelastomer 04-6207

4 x Adaptors

Refer to seperate table

Holder

4 vial 60 ml flasks

04-6125

Page 33: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 29

Aluminium Polypropylene Drying Adaptors

Type Vial Size Part number

AA

Maximum Ø 17.3 mm Length 48.5 to 51.5 mm 04-6156

AB

Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6155

AC

Maximum Ø 20.3 mm Length 48.5 to 51.5 mm 04-6166

AD

Maximum Ø 13.5 mm Length 38.5 to 41.5 mm 04-6174

AE

Maximum Ø 11.8 mm Length 30.5 to 33.5 mm 04-6214

AF Maximum Ø 15.3 mm Length 48.5 to 51.5 mm 04-4686

AG

Maximum Ø 11.8 mm Length 45.5 to 48.5 mm

04-6615

AH Maximum Ø 19.8 mm Lengh 38.5 to 41.5 mm 04-6619

Polypropelene Lyophilisation / Concentration Adaptors

Type Vial Size Part number

AA

Maximum Ø 17.3 mm Length 48.5 to 51.5 mm 04-6110

AB

Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6130

AC

Maximum Ø 20.3 mm Length 48.5 to 51.5 mm 04-6167

AD

Maximum Ø 13.5 mm Length 38.5 to 41.5 mm 04-6175

AE

Maximum Ø 11.8 mm Length 30.5 to 33.5 mm 04-6125

AF

Maximum Ø 15.3 mm Length 48.5 to 51.5 mm 04-4688

AG

Maximum Ø 11.8 mm Length 45.5 to 48.5 mm

04-6614

AH Maximum Ø 19.8 mm Lengh 38.5 to 41.5 mm 04-6618

Page 34: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

30 10-1478 - Issue 4-15 September 2009

SampleGenie - 125 ml

Assembly Vial Size Quantity Part number

Range: Ø 11.8 to 28.3 mm Length 32 to 60 mm

2 70-1151

The SampleGenie assembly includes Flasks, Holder, Cushions and black viton seals. Due to the wide range of options, Adaptors must be specified separately. Alternative seal options (low leachable white viton or highly resistant FFKM perflouroelastomer) may also be specified at point of order.

Sub Assembly Parts

Description Specification Part number

2 x 125 ml Flask

Borosilicate glass 04-6047 25 mm Viton 04-6142 25 mm With Viton 04-6231

2 x Seal

25 mm Perflouroelastomer 04-6231

2 x Cushions

04-6595

2 x Adaptors

Refer to seperate table

Holder

2 vial 125 ml flasks

04-6188

Page 35: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 31

Aluminium Polypropelene Drying Adaptors

Type Vial Size Part number

BA

Maximum Ø 27.3 mm Length 58.5 to 61.5 mm

04-6048

BB

Maximum Ø 16.8 mm Length 33.5 to 36.5 mm 04-6161

BC

Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6162

BD

Maximum Ø 28.3 mm Length 58.5 to 61.5 mm 04-6190

BE

Maximum Ø 11.8 mm Length 30.5 to 33.5 mm 04-6216

BF

Maximum Ø 17.3 mm Length 58.5 to 61.5 mm 04-6292

BG

Maximum Ø 15.3 mm Length 48.5 to 51.5 mm 04-6378

BH

Maximum Ø 17.3 mm Length 48.5 to 51.5 mm 04-6390

BJ

Maximum Ø 23.8 mm Length 58.5 to 61.5 mm 04-6454

BK

Maximum Ø 21.8 mm Length 55.5 to 58.5 mm 04-6606

Polypropelene Lyophilisation / Concentration Adaptors

Type Vial Size Part number

BA

Maximum Ø 27.3 mm Length 58.5 to 61.5 mm 04-6049

BB

Maximum Ø 16.8 mm Length 33.5 to 36.5 mm 04-6159

BC

Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6160

BD

Maximum Ø 28.3 mm Length 58.5 to 61.5 mm 04-6192

BE

Maximum Ø 11.8 mm Length 30.5 to 33.5 mm 04-6217

BF

Maximum Ø 17.3 mm Length 58.5 to 61.5 mm 04-6293

BG

Maximum Ø 15.3 mm Length 48.5 to 51.5 mm 04-6377

BH

Maximum Ø 17.3 mm Length 48.5 to 51.5 mm 04-6389

BJ

Maximum Ø 23.8 mm Length 58.5 to 61.5 mm 04-6453

BK

Maximum Ø 21.8 mm Length 55.5 to 58.5 mm 04-6605

Page 36: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

32 10-1478 - Issue 4-15 September 2009

SampleGenie - 250 ml

Assembly Vial Size Quantity Part number

Range: Ø 11.8 to 28.3 mm Length 32 to 70 mm

1

70-1152

The SampleGenie assembly includes Flask, Holder, Cushion and black viton seal. Due to the wide range of options, Adaptors must be specified separately. Alternative seal options (low leachable white viton or highly resistant FFKM perflouroelastomer) may also be specified at point of order.

Sub Assembly Parts Description Specification Part number

250 ml Flask

Borosilicate glass 04-6140 25 mm Viton 04-6142 25 mm White Viton 04-6231

Seal

25 mm Perflouroelastomer 04-6208

Adapter

Refer to separate table

Cushion

04-6187

Holder

1 vial 250 ml flask 04-6141

Page 37: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 33

Aluminium Polypropylene Drying Adaptors

Type Vial Size Part number

CA

Maximum Ø 27.3 mm Length 68.5 to 71.5 mm 04-6163

CB

Maximum Ø 28.3 mm Length 68.5 to 71.5 mm 04-6168

CC

Maximum Ø 27.3 mm Length 58.5 to 61.5 mm 04-6182

CD

Maximum Ø 17.3 mm Length 58.5 to 61.5 mm 04-6184

CE

Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6186

CF

Maximum Ø 11.8 mm Length 30.5 to 34.5 mm 04-6218

CG

Maximum Ø 28.3 mm Length 58.5 to 61.5 mm 04-6238

CH

Maximum Ø 21.3 mm Length 68.5 to 71.5 mm 04-6363

Polypropelene Lyophilisation / Concentration Adaptors

Type Vial Size Part number

CA

Maximum Ø 27.3 mm Length 68.5 to 71.5 mm 04-6144

CB

Maximum Ø 28.3 mm Length 68.5 to 71.5 mm 04-6169

CC

Maximum Ø 27.3 mm Length 58.5 to 61.5 mm 04-6170

CD

Maximum Ø 17.3 mm Length 58.5 to 61.5 mm 04-6171

CE

Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6172

CF

Maximum Ø 11.8 mm Length 30.5 to 34.5 mm 04-6219

CG

Maximum Ø 28.3 mm Length 58.5 to 61.5 mm 04-6239

CH

Maximum Ø 21.3 mm Length 68.5 to 71.5 mm 04-6245

Page 38: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

34 10-1478 - Issue 4-15 September 2009

Thermal Cushion

Description

Quantity Part number

For use with 25 ml Flask

(Pack of 96) 10-1551

Ex-Stock

For use with 50 ml Flask

(Pack of 96) 10-1556

Ex-Stock

For use with 100 ml Flask

(Pack of 48) 10-1555

Ex-Stock

For use with 170 / 250 ml Flask

(Pack of 48) 10-1554

Ex-Stock

For use with 250 ml Flask

(Pack of 12) 10-1553

Ex-Stock

For use with 500 ml Flask

(Pack of 12) 10-1552

Ex-Stock

Page 39: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 35

Notes

Page 40: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

36 10-1478 - Issue 4-15 September 2009

Sample Holder Part Number Index 10-5000............... 10 10-5025............... 10 10-5047............... 10 10-5001............... 10 10-5002............... 11 10-5003............... 11 10-5046............... 11 10-5008............... 11 10-5048............... 11 10-5004............... 12 10-5005............... 12 10-5042............... 12 10-1005............... 12 10-5006............... 12 10-5009............... 13 10-5044............... 13 10-5045............... 14 10-5029............... 14 10-5032............... 14 10-5024............... 14 10-5034............... 14 10-5035............... 15 10-5016............... 15 10-5037............... 15 10-5021............... 15 10-5038............... 15 10-5067............... 16 10-5028............... 16 10-5007............... 16 10-5030............... 17

10-5031 ...............17 10-5033 ...............18 10-5036 ...............18 10-5040 ...............18 10-5039 ...............18 10-5041 ...............18 10-5062 ...............19 10-5019 ...............19 10-5014 ...............19 10-5013 ...............19 10-5010 ...............20 10-5068 ...............20 70-0057 ...............21 70-0009 ...............21 70-0058 ...............21 70-0774 ...............21 10-5049 ...............22 10-5043 ...............22 10-5011 ...............22 10-5058 ...............22 10-5059 ...............22 10-5027 ...............23 10-5020 ...............23 10-5017 ...............23 10-5050 ...............24 10-5022 ...............24 10-5055 ...............24 10-5015 ...............24 10-5052 ...............24 10-5064 ...............24

70-0538............... 25 70-0539............... 25 70-0656............... 25 70-1026............... 25 70-0657............... 25 70-0579............... 25 70-0658............... 25 70-0581............... 26 70-0705............... 26 70-0706............... 26 70-1021............... 26 70-0580............... 26 70-0582............... 27 10-1616............... 27 10-5017............... 28 70-1031............... 28 10-6068............... 28 70-0924............... 28 10-5065............... 29 10-5053............... 29 10-5054............... 29 70-1004............... 30 70-1025............... 31 10-5060............... 31 10-5063............... 31 10-5061............... 31 70-0716............... 32

Page 41: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Options and Accessory Brochure

10-1478 - Issue 4-15 September 2009 37

Sample Holder Part Number Cross Reference

Old New

............... 10-1616 70-0005............... 10-5037 70-0007............... 10-5035 70-0008............... 10-5049 70-0019............... 10-5024 70-0024............... 10-5031 70-0052............... 10-5043 70-0055............... 10-5019 70-0072............... 10-5028 70-0073............... 10-5029 70-0538............... 70-0539............... 70-0550............... 10-5053 70-0551............... 10-5054 70-0579...............

Old New 70-0580 ............... 70-0582 ............... 70-0633 ............... 10-5014 70-0646 ............... 10-5051 70-0656 ............... 70-0657 ............... 70-0660 ............... 10-5025 70-0661 ............... 10-5001 70-0663 ............... 10-5002 70-0665 ............... 10-5004 70-0666 ............... 10-5006 70-0667 .............. 10-5027 70-0668 ............... 10-5015 70-0669 ............... 10-5023 70-0670 ............... 10-5026 70-0671 ............... 10-5027

Old New 70-0673 ............... 10-5034 70-0674 ............... 10-5038 70-0675 ............... 10-5030 70-0676 ............... 10-5013 70-0719 ............... 10-5036 70-0720 ............... 10-5009 70-0724 ............... 10-5010 70-0759 ............... 10-5040 70-0777 ............... 10-5005 70-0778 ............... 10-5022 70-0780 ............... 10-5020 70-0794 ............... 10-5050 70-0928 ............... 10-5042 ................ 10-5017 70-1025 ............... ................ 10-5060

Swing Part Number Cross Reference

Old New

70-0001............... 70-0959 70-0091............... 70-0578 70-0093............... 70-0578 70-0110............... 70-0578 70-0354............... 70-0959 70-0620............... 70-0959

Page 42: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Amendment Control Form

Issue Reason for Change Date Issued

1 Introduction of 500ml Flask Holder for HT Series II 30-Nov-05 2 Corrected image for 10-5042 31-Jul-06 3 Introduction of Schott Bottle & Beaker holders 13-Nov-06 4 Waters Fraction Collection Rack – Options updated 20-Aug-07 5 Addition of tube holder 10-5000 31-Jan-08 6 Addition of Maintenance of Sample Holder 17-Apr-08

4-7 Update U.S. address 24-Oct-08 4-8 Amend layout 16-Jan-09 4-9 Correct title Centrifuge Tube Holder Options – Swing 27-Jan-09 4-10 Update Sample Holder Part number Index 16-Feb-09 4-11 Remove Mega Sample Holders 26-Feb-09 4-12 Introduced sampleGenie and updated list of holders 27-Aug-09 4-13 Added SampleGenie vial adaptors AG and AH 1-Sep-09 4-14 Added Swing/Holder type, amend 10-5063 compatibility 16-Sep-09

4-15 Added Glassware Labels, Compatibility with other Manufacturers, added Waters Collection Rack illustrations, removed various special holders.

23-Sep-09

Page 43: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation
Page 44: Genevac HT and EZ-2 Series Evaporators HT and EZ-2 Series Evaporators ... HCl or Thionyl Chloride ... capacity and a wide variety of sample formats. In order to optimise the evaporation

Genevac Limited The Sovereign Centre

Farthing Road Ipswich IP1 5AP

United Kingdom

Sales and Service Hotlines

Service Hotline: +44 (0) 1473 243000

Sales Hotline: +44 (0) 1473 240000

Fax: +44 (0) 1473 461176

Email: mailto:[email protected]

Web site: http://www.genevac.com

Genevac Inc SP Industries

815 State Route 208 Gardiner

NY, 12525 United States of America

Sales and Service Hotline

(1) 845 267 2212

Fax (1) 845 267 2212

Email: [email protected]

Genevac Technology is protected by patents and patent applications in the UK and worldwide. Genevac Ltd has a continuous development programme aimed at further improving their products and all specifications are, therefore, subject to change. Coolheat®, VacRampTM (Dri-Pure®), SampleGuardTM and associated logos are trade marks of

Genevac Ltd, unauthorised use is prohibited.