genevac ht and ez-2 series evaporators ht and ez-2 series evaporators ... hcl or thionyl chloride...
TRANSCRIPT
GGeenneevvaacc HHTT aanndd EEZZ--22 SSeerriieess EEvvaappoorraattoorrss
OOppttiioonnss && AAcccceessssoorriieess BBrroocchhuurree
1100--11447788 IIssssuuee 44--1155
SSeepptteemmbbeerr 22000099
AAddddiittiioonnaall SSaammppllee HHoollddeerrss aarree aavvaaiillaabbllee,, yyoouurr SSaalleess RReepprreesseennttaattiivveess ccaann aaddvviissee oonn aallll aaddddiittiioonnaall iitteemmss,, iinncclluuddiinngg ssppeecciiaall oorrddeerr iitteemmss..
Contents Introduction ............................................................................................................... 1
The Range............................................................................................................................ 1 Minimum Order Quantities ................................................................................................... 2 Nomenclature ....................................................................................................................... 2 Heat Transfer........................................................................................................................ 2 Protective Coatings .............................................................................................................. 2 HCl or Thionyl Chloride ........................................................................................................ 2 Glassware Labels................................................................................................................. 3 Sample Capacity .................................................................................................................. 3 Rotors ................................................................................................................................... 3 Special Applications ............................................................................................................. 3 Compatibility with Other Manufacturers ............................................................................... 4 Swing / Holder Type ............................................................................................................. 4
Maintenance .............................................................................................................. 5 Inspection ............................................................................................................................. 5 Cleaning ............................................................................................................................... 5 Tube Breakage..................................................................................................................... 5
Swings........................................................................................................................ 6 Fast-stack ............................................................................................................................. 6 Side-bridge ........................................................................................................................... 6
Tube Holders ............................................................................................................. 7 Tube Holders for Side Bridge Swings .................................................................................. 7 One Piece Tube Holders .................................................................................................... 10
Vial Holders ............................................................................................................. 12 Vial Holders for Side Bridge Swings................................................................................... 12 One Piece Vial Holders ...................................................................................................... 17
Centrifuge ................................................................................................................ 18 Centrifuge Tube Holders .................................................................................................... 18 Microcentrifuge Tube Holders ............................................................................................ 18
Bottle Holders.......................................................................................................... 19 Flask Holders........................................................................................................... 20 Microplate Heat Transfer Plates ............................................................................ 22 Gilson and Waters Fraction Collection Racks ..................................................... 24 Miscellaneous.......................................................................................................... 26
Sample Guard Probes........................................................................................................ 26 Thermal Cushion Accessories............................................................................................ 26
SampleGenie ........................................................................................................... 27 SampleGenie - 60 ml.......................................................................................................... 28 SampleGenie - 125 ml........................................................................................................ 30 SampleGenie - 250 ml........................................................................................................ 32
Thermal Cushion..................................................................................................... 34 Sample Holder Part Number Index ........................................................................ 36 Sample Holder Part Number Cross Reference..................................................... 37 Swing Part Number Cross Reference ................................................................... 37 Amendment Control Form...................................................................................... 38
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 1
Introduction
Genevac evaporators are designed to combine rapid and safe evaporation with high capacity and a wide variety of sample formats. In order to optimise the evaporation performance achieved it is important to select the correct sample holder for your particular application.
Genevac sample holders are manufactured from solid high grade aluminium to very precise specifications and are mass balanced to ensure smooth running of the evaporator.
This guide will help you make the right choice.
The Range
This guide includes the current range of Genevac sample holders which are coloured bright blue for identification purposes. These sample holders are designed for use in an HT series II system, an EZ-2 series system, or may be used in either.
Due to height and weight limitations, a small number of holders have limited compatibility and are not suitable for use with certain systems. Any holder which is subject to a limitation of compatibility, it is highlighted within this brochure. An example of such a limitation is shown below:
Not for use with EZ-2 MK1
In this instance, the sample holder must not be used in an EZ-2 MK1. The EZ-2 Mk1 can be identified by the large circular window in the chamber lid, EZ-2 mk2 and EZ-2 Mk3 has a solid lid with a small tear drop window.
Blue sample holders are not interchangeable with the older range of holders and swings. To choose the correct new holder, refer to the: Sample Holder Part Number Cross Reference.
Should you require an old design of holder, a holder for use in a Genevac HT series 1 system, or a holder for a tube which is not listed, please contact your local Genevac representative or sales agent.
Options and Accessory Brochure
2 10-1478 - Issue 4-15 September 2009
Minimum Order Quantities
The minimum order quantity for Genevac sample holders is two, larger orders should be for an even number (paired sets) of holders. This also applies to associated parts such as swings, heat transfer plates, SampleGenie assemblies etc.
Nomenclature
Tube holder A holder which accommodates tubes with rounded ends
Vial Holder A holder which accommodates vials with flat ends
Bottle holder A holder which accommodates bottles with flat ends
Flask holder A holder which accommodates round bottom flasks. Holders for tubes with conical or tapered ends are identified individually.
Heat Transfer
A major factor in determining the speed of evaporation is the rate at which heat can transfer to the sample. Greater heat transfer rates mean faster evaporation.
Here are two ways that Genevac HT series II and EZ-2 series evaporators optimise heat transfer:
• High quality aluminium rotors and holders. Recommended for its properties of high thermal conductivity and low weight, Genevac systems use aluminium sample holders which have particularly efficient heat transfer properties.
• High quality engineering. Genevac samples holders are manufactured to very precise specifications. Tubes fit very snugly into the tube holders as any gaps would slow down the rate of heat transfer. This is why it is important to provide us with a sample of tubes when placing orders for sample holders.
Protective Coatings
Standard aluminium sample holders are Hard Anodised (water sealed) for protection against all normal organic solvents, including strong acids such as TFA, HCl and thionyl chloride.
HCl or Thionyl Chloride
To evaporate HCl or thionyl chloride, it is necessary to purchase a system (comprising of: evaporator, condenser and pump) which is HCl and thionyl chloride resistant. These systems are specifically built to resists attack from HCl and thionyl chloride.
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 3
Glassware Labels
There are two common methods of labelling glassware in laboratories; both can cause problems in the evaporator.
Paper or film labels The label effectively increases the tube diameter and the problem is exaggerated if the label overlaps itself. The tube or vial no longer fits snugly into the holder, high spots cause stress in the glass and compromise efficient heat transfer from the holder.
Ceramic Etched Ceramic labels etch the glass and may weaken it. Genevac recommend testing new tubes for breakage before buying large numbers.
Sample Capacity
Genevac uses the latest computer aided design technology to ensure evaporators have maximum internal capacity within a minimal instrument footprint. This means high throughput evaporation is possible from an instrument taking up a small amount of bench top space.
Rotors
For information on Genevac rotors, please refer to the Quick Guide to HT Series Rotors available to download from our web site.
Special Applications
As the market leader in centrifugal evaporation, Genevac have already designed holders for the majority of applications. Please examine the list on the following pages, to find the correct part number.
Should you have a special application or unusual tube size, we can design a special holder for you. Please note there is a nominal charge to cover design time for this service. Our experienced sales team (or international distributors) will be pleased to advise you of the options available.
Options and Accessory Brochure
4 10-1478 - Issue 4-15 September 2009
Compatibility with Other Manufacturers
Check the Genevac website for guides to compatibility with Radleys and Metler Toledo Autochemistry (Bohdan) products.
Swing / Holder Type
Genevac offers a comprehensive range of sample holders. Some are designed for use with swings, others are one piece holders which fit straight onto the evaporator rotor. In the following sections of this brochure, Sample Holders for Side-bridge Swings are listed separately from One Piece Holder-swings.
One Piece Holder-swing
Sample Holder and Side-bridge Swing
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 5
Maintenance
Inspect and clean the sample holders at least monthly. Always dry the sample holders thoroughly after cleaning, never use wet sample holders in a Genevac system.
The following inspection routine is mandatory following tube breakage or solvent spillage.
Inspection
Visually inspect the swings and sample holders and clean off any debris, especially in the sample holder wells. High points, caused by debris, lead to stress in the glassware and may result in breakage.
The most common cause of repeat glassware breakage is a fragment from a previously broken tube. Solvent can stick glass fragments to the holder making it difficult to remove. Any residual solvent or sample material must be cleaned off.
Superficial surface damage (scratches) do not affect the performance of a sample holder. However, if there is any structural damage (if any part of the sample holder is bent or deformed) do not use it. Contact Genevac Service for evaluation.
Repeated use with strong acids is likely to cause colour fading of the sample holder over time. This is normal and does not affect the integrity of the holder.
Cleaning
Loose dirt and debris can be removed using a brush, a compressed-air line may also be used if this is available. Adhered dirt, debris or sample / solvent residue should be cleaned off using methanol or acetone, soak the sample holders if necessary. The sample holders should then be washed in clean water and fully dried before use.
Tube Breakage
The precision design of all Genevac sample holders contributes, not only to their excellent heat transfer properties and superior evaporation performance, it also ensures that tubes have maximum protection from breakage during evaporation. For additional protection against glassware breakage, some flask holders and some tube holders are designed for use with thermal cushions. Thermal cushions are made from a filled polymer with excellent heat transfer and cushioning properties.
Use only borosilicate tubes with a wall thickness greater than 1.2 mm in Genevac evaporators. Do not use old, damaged or scratched glassware. In laboratories where tubes or vials are reused, each tube or vial must be regularly inspected for damage. Discard any scratched or cracked items.
For more information and advice on this subject, please refer to the Genevac document entitled: Safe Loading. This is available to download from our web site.
Options and Accessory Brochure
6 10-1478 - Issue 4-15 September 2009
Swings
Fast-stack
Description Specification Part number
standard
70-0092
Holds 4 x shallow well microtitre plates Max plate area: 129.0 x 87.0 x 19.0 mm Mass = 523g
HCl 70-0089
Holds 2 x deep well Micro-Tube Cluster Racks Max plate area: 129.0 x 87.0 x 54.0 mm Mass = 580g Not for use with EZ-2mk1
HCl 70-0959
Side-bridge
Description Specification Part number
Holds 1 x Genevac tube or vial holder Or 1 x Radleys GreenHouse Block Max foot-print: 129.0 x 87.0 mm Mass = 380g
HCl
70-0578
Holds 1 x MT Autochem Miniblock Tube length up to 112 mm For use with HT series II systems only
HCl
70-1053
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 7
Tube Holders
Tube Holders for Side Bridge Swings
Tube Specification
Quantity Part number
10 mm x 75 mm Limits: Ø 9.8 to 10.3 mm Length 55 to 75 mm
40 10-5000
12 mm x 75 mm Limits: Ø 11.8 to 12.3 mm Length 55 to 75 mm
40 10-5025
12 mm x 100 mm Limits: Ø 11.8 to 12.3 mm Length 75 to 110 mm
40 10-5001
13 mm x 75 mm Limits: Ø 12.8 x 13.3 Length 55 to 75 mm
40 10-5047
13 mm x 100 Limits: Ø 12.8 x 13.3 mm Length 75 to 110
40 10-5002
13.5 mm x 100 mm Limits: Ø 13.3 to 13.8 mm Length 75 to 100 mm
40 10-5003
Options and Accessory Brochure
8 10-1478 - Issue 4-15 September 2009
Tube Specification Quantity Part number
15 mm x 75 mm Limits: Ø 14.8 to 15.3 mm Length 55 to 75 mm
28 10-5046
15 mm x 100 mm Limits: Ø 14.8 to 15.3 mm Length 75 to 110 mm
28 10-5008
16 mm x 75 mm Limits: Ø 15.8 to 16.3 mm Length 55 to 75 mm
24 10-5048
16 mm x 100 mm Limits: Ø 15.8 to 16.3 mm Length 75 tp 110 mm
24 10-5004
17mm x 85mm Tapered Microwave Limits: Ø 16.3 to 17.3 mm Length 75 to 90 mm
24 10-5042
17mm x 75 to 110mm Straight Microwave Limits: Ø 16.8 mm to 17.3 mm Length 75 to 110 mm
24 10-5005
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 9
Tube Specification
Quantity Part number
18 mm x 100 mm Limits: Ø 17.8 to 18.3 mm Length 75 to 110 mm
24 10-5006
24 mm x 100 mm Limits: Ø 23.8 to 24.3 mm Length 75 to 110 mm
12 10-5044
25 mm x 100 mm Limits: Ø 24.8 to 25.3 mm Length 75 mm to 110 mm
12 10-5009
Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s).
Options and Accessory Brochure
10 10-1478 - Issue 4-15 September 2009
One Piece Tube Holders Tube Specification Quantity
Part number
16 mm x 150 mm Limits: Ø 15.8 to 16.3 mm Length 110 to 152 mm
12 10-5020
16.5 mm x 125 mm Limits: Ø 16.3 to 16.8 mm Length 110 to 132 mm
20
10-5050
17 mm x 150 mm Limits: Ø 16.8 to 17.3 mm Length 110 to 152 mm
12 10-5022
17.5 mm x 140 mm Limits: Ø 17.0 to 17.8 mm Length 105 to 142 mm
12 10-5055
18 mm x 150 mm Limits: Ø 17.8 to 18.3 mm Length 110 to 152 mm
12 10-5015
20 mm x 150 mm Limits: Ø 19.8 to 20.3 mm Length 110 to 152 mm
10 10-5023
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 11
Tube Specification Quantity
Part number
24 mm x 110 to 150 mm Limits: Ø 28.8 to 24.3 mm Length 110 to 152 mm Radleys Carousel tube 6 and STEM reaction stations
6 10-5026
25 mm x 15 mm Limits: Ø 24.8 to 25.3 mm Length 110 to 152 mm
6 10-5027
27.5 mm x 140 mm Limits: Ø 27.0 to 27.8 mm Length 105 to 142 mm
6 10-5017
40 mm x 100 mm Limits: Ø 39.8 to 40.3 mm Length 90 to 105 mm
5 10-5052
45 mm x 150 mm Limits: Ø 44.8 to 45.8 mm Length 110 to 152 mm
2
10-5064
Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s).
Options and Accessory Brochure
12 10-1478 - Issue 4-15 September 2009
Vial Holders
Vial Holders for Side Bridge Swings
Vial Specification
Quantity Part number
10 mm x 45 mm Limits: Ø 9.5 to 10.3 mm Length 35 to 45 mm
48 10-5029
11 mm x 35 mm Limits: Ø 10.7 to 11.5 mm Length 30 to 40 mm
48 10-5032
12 mm x 35 mm GC auto-sampler vial Limits: Ø 11.3 to 12.1 mm Length 30 to 40 mm
48 10-5024
13 mm x 50 mm 4 ml crimp top HPLC vial Limits: Ø 12.5 to 13.3 mm Length 30 to 50 mm
40 10-5034
14.5 mm x 45 mm Limits: Ø 14.0 to 14.8 mm Length 35 to 50 mm
24 10-5035
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 13
Vial Specification
Quantity Part number
14.5 mm x 65 mm Limits: Ø 14.0 to 14.8 mm Length 55 to 75 mm
24 10-5016
15 mm x 45 mm Limits: Ø 14.3 to 15.1 mm Length 35 to 50 mm
24 10-5037
15 mm x 65 mm Limits: Ø 14.7 to 15.7 mm Length 55 to 75 mm
24 10-5021
15.5 mm x 45 mm Limits: Ø 15.0 to 15.8 mm Length 35 to 50 mm 1 DRAM & 4ml HPLC screw top vial
24 10-5038
16.5 mm x 65 mm Limits: Ø 16.2 to 17.0 mm Length 55 to 75 mm
24 10-5028
16 mm x 100 mm Limits: Ø 15.5 to 16.3 mm Length 75 to 110 mm
24 10-5067
Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s).
Options and Accessory Brochure
14 10-1478 - Issue 4-15 September 2009
Vial Specification
Quantity Part number
17 mm x 40 mm Limits: Ø 16.3 to 17.1 mm Length 38 to 50 mm
24 10-5007
17 mm x 75 mm 2 dram vial Limits: Ø 16.5 to 17.3 mm Length 55 to 75 mm
24 10-5030
17.5 mm x 45 mm Limits: Ø 17.0 to 17.8 mm Length 40 to 50 mm
24 10-5031
18 mm x 45 mm Limits: Ø 17.7 to 18.5 mm Length 40 to 50 mm
24 10-5033
20 mm x 65 mm Limits: Ø 19.m to 20.3 mm Length 55 to 75 mm
18 10-5036
20.5 mm x 65 mm Limits: Ø 20.2 to 20.8 mm Length 55 to 75 mm
18 10-5040
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 15
Vial Specification Quantity Part number
21 mm x 65 mm Limits: Ø 20.5 to 21.3 mm Length 55 to 75 mm
18
10-5039
21.5 mm x 65 mm Limits: Ø 21.1 to 21.8 mm Length 55 to 75 mm
18 10-5041
22.5 mm 50 mm Limits: Ø 22.0 to 22.8 mm Length 38 to 50 mm
12 10-5062
23.5 mm x 54 mm Limits: Ø 23.0 to 23.8 mm Length 55 to 75 mm
12 10-5019
24 mm x 65 mm Limits: Ø 23.7 to 24.5 mm Length 55 to 75 mm
12 10-5014
27.5 mm x 65 mm Limits: Ø 27.0 to 27.8 mm Length 55 to 75 mm 20ml Scintilation Vial
12 10-5013
Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s).
Options and Accessory Brochure
16 10-1478 - Issue 4-15 September 2009
Vial Specification Quantity Part number
27.5 mm x 100 mm 40 ml scintillation vial Limits: Ø 27.0 to 27.8 mm Length 75 to 110 mm
8 10-5010
34 mm x 110 mm 50 ml Schott Duran tube No 21617 17
6 10-5059
35 mm x 100 mm Limits: Ø 34.5 to 35.8 mm Length 75 to 110 mm
6 10-5068
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 17
One Piece Vial Holders
Vial type
Quantity Part number
25 mm x 120 mm Limits: Ø 24.5 to 25.3 mm Length 85 to 122 mm For use with EZ-2 only
70-0924
25 mm x 150 mm Limits: Ø 24.5 to 25.3 mm Length 110 to 152 mm
6 70-1031
27.5 mm x 140 mm Dionex ASE® tube Limits: Ø 27.0 to 27.8 mm Length 105 to 142 mm
6 10-5017
35 mm x 100 mm Limits: Ø 34.5 to 35.8 mm Length 75 to 110 mm
6 10-5068
Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s). ASE® is a registered trademark of Dionex Corporation
Options and Accessory Brochure
18 10-1478 - Issue 4-15 September 2009
Centrifuge
Centrifuge Tube Holders
Tube type
Quantity Part number
16.5 mm x 110 mm 12° end 10 ml Limits: Ø 16.0 to 16.8 mm Length 95 to 110 mm Requires viton insert
24 10-5065
16.5 mm x 115 mm 30° end 15 ml centrifuge tube Limits: Ø 16.3 to 17.3 mm Length 100 to 120 mm
24 10-5053
29.5 mm x 115 mm 70° end 50 ml centrifuge tube Limits: Ø 28.5 to 29.8 mm Length 100 to 115 mm
10 10-5054
Microcentrifuge Tube Holders
Tube type
Quantity Part number
8 mm x 30 mm 0.5 ml flip cap, without skirt
50 10-5049
10 mm x 40 mm 1.5 ml flip cap, without skirt
32 10-5043
10 mm x 47 mm 2.0 ml flip cap, without skirt
24 10-5011
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 19
Bottle Holders
Bottle Specification
Quantity Part number
55.5 mm x 100 mm Schott 100 ml Limits: Ø 54.0 to 56.0 Length 90 to 110 mm
2 70-1025
70 mm x 140 mm Schott 250 ml 400 ml Fisher Beaker No FB33124 Requires Thermal Cushion
1 10-5060
82 mm x 152 mm 500 ml bottle Requires thermal Cushion Not for use with EZ-2 MK 1
1 10-5063
60.5 mm x 125 mm 250 ml Nalge Nunc no 3127-0250
2 10-5061
Note: Images are for guidance only. Where no image is shown, appearance is similar to the preceding holder(s).
Options and Accessory Brochure
20 10-1478 - Issue 4-15 September 2009
Flask Holders Flask Specification Quantity
Part number
25ml Socket Size 19/26 – 24/29
6 70-0538
50ml Socket Size 29/32
4 70-0539
50ml Socket size 19/26 to 24/29
4 70-0656
50 ml Socket size 24/29 to 29/32
4 70-1026
100ml Socket size 19/26 to 24/29 Including Radleys 6 Pace Carousel For use with EZ-2 only
3 70-0657
100ml Socket size 29/36 to 19/32 For use with EZ-2 only
3 70-0579
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 21
Flask Specification Quantity
Part number
250 ml Socket size 19/22 to 29/32 Including Radleys 6 Place Carousel
1 70-0580
500 ml Socket Size 19/32 to 29/32 For use with EZ-2 Only
1
70-0582
500 ml Socket size 19/32 to 29/21 Max flask height: 156 mm For use with HT series II 0nly
1
10-1616
Note: To prolong glassware lifetime and dramatically reduce sample drying time, these round bottom flask holders must be used with Genevac Thermal Cusion.
Options and Accessory Brochure
22 10-1478 - Issue 4-15 September 2009
Microplate Heat Transfer Plates
Heat transfer plates are available for use in open swings, side bridge swings, and most Fast Stack holders.
This range of sample holders provide improved evaporation results when using deep well microtitre plates. Heat Transfer Plates are designed to support the wells of the plate, fitting precisely to the base of the wells, and where possible, to the sides of each well.
Heat transfer plates confer three main benefits:
• Excellent heat transfer rates, up to 50% reduced evaporation times when using micro plates.
• Even sample drying
• Support for micro plates when used in open swings, preventing potentially harmful direct heating by lamps, and preventing plate deformation by heat and G-force.
Heat transfer plates must be used when using microtube cluster racks, e.g. Micronics or ABgene racks, in Genevac open swings.
If you would like a micro plate evaluated to see if a suitable Heat Transfer Plate exists, or would like further information, please contact your Genevac representative.
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 23
Description Use
Part number
Max foot-print: 128.0 x 86.5 mm Mass = 200 g
For use in
Side-bridge Sswing
70-0086
Ex-Stock
Compatible with: Falcon, Micronic Traxis and Micronic Multi-Tube Cluster Racks Round end tubes
For use in
Side-bridge Swing
70-0084
Special order
Compatible with: Beckman 1 ml x 96 O Beckman 2 ml x 96 Costar 1 ml x 96 O Costar 2 ml x 96 Whatman 2 ml x 96
For use in
Side-bridge Swing
70-0085
Special order
Compatible with: Axygen 2 ml x 96 O Greiner 1 ml x 96 O Nunc 2 ml x 96 O Nunc 1 ml x 96 O Whatman 1 ml x 96 O
For use in
Side-bridge Swing
70-0087
Special order
Compatible with: MultiChem 10 ml x 24 O Polyfiltronics 10 ml x 24 O UniPlates 10 ml x 24 O Whatman 10 ml x 24 O
For use in Deep-well
swing
70-0357
Special order
Compatible with: ABgene Multi-tube Cluster Racks Round end tubes
For use in Deep-well
swing
70-0361
Special order
The items listed above are a small example from the range of heat transfer plates that Genevac can provide. Please contact your sales representative for details.
Options and Accessory Brochure
24 10-1478 - Issue 4-15 September 2009
Gilson and Waters Fraction Collection Racks
Genevac offer a range of innovative options that help interface fraction collection systems directly to the Genevac HT series evaporator. Currently Gilson 215 and Waters 2767 systems are supported.
To interface with the fraction collections system, Genevac provide a simple sample holder carrier which fits directly on to the fraction collection bed. Genevac sample holders fit into the carrier to make up a complete fraction collection rack. Once fractions are collected, the sample holders can be placed directly into the Genevac evaporator with no need to label, mark or manipulate individual tubes. Sample holders can be marked to indicate their location within the fraction collection rack.
There are a range of options, some use standard sample holders, some use specially designed holders which keep the spacing between tubes uniform, and reduce fraction collector reprogramming. Waters 2767 users will require the adaptor plate when using 16 mm diameter tubes.
Further information, including a technical article discussing these issues in greater detail, is available upon request from your Genevac representative.
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 25
Description Use Part number
Holds Qty 4 tube holders (examples: 10-5020 or 10-5027)
Rack for use
with Waters Fraction
Collection
10-1570
Special order
Converts Waters 2767 Sample Manager Rack Bed to hold 3 Racks
Adapter Plate
for rack 10-1570
04-4181
Special order
Converts Waters 2767 Sample Manager Rack Bed To hold 14 MAX SideBridge Holders
Adapter plate
for Side-bridge
Holders
04-4330
Special order
The items listed above are a small example from the range of fraction collector racks that Genevac can provide. Please contact your sales representative for details.
Options and Accessory Brochure
26 10-1478 - Issue 4-15 September 2009
Miscellaneous
Sample Guard Probes
Description
Specification Part number
SampleGuard Temperature Probe
CH1 & CH2 Short FastStack Swing Solid Holder Length 160 mm
Standard
HCl
70-0163
70-0197
CH2 Medium Length 220 mm
Standard
HCl
70-0168
70-0200
CH2 Long Length 280 mm
Standard
HCl
70-0210
70-0212
Thermal Cushion Accessories Description
Use Part number
Applicator
For use with
Thermal Cushion
04-3822
Ex-Stock
Spatula
For use with
Thermal Cushion
04-3869
Ex-Stock
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 27
SampleGenie
Designed for situations where large volumes need to be dried or concentrated into a small vial. SampleGenie™ comprises sample tube and sample holder technology which enables large volume samples to be dried or concentrated directly into a variety of small vials. Where HPLC purification fractions are used, fractions are combined into one tube and and dried or fast lyophilised into the final vial.
Options and Accessory Brochure
28 10-1478 - Issue 4-15 September 2009
SampleGenie - 60 ml
Assembly Vial Size Quantity Part number
Range: Ø 11.8 to 20.3 mm Length 32 to 50 mm
4 70-1150
The SampleGenie assembly includes Flasks, Holder and black viton Seals. Due to the wide range of options, Adaptors must be specified separately. Alternative seal options (low leachable white viton or highly resistant FFKM perflouroelastomer) may also be specified at point of order.
Subassembly Parts
Description Specification Part number
4 x 60 ml Flask
Borosilicate glass 04-6124 20.5 mm black viton 04-6108 20.5 mm white viton
04-6230
4 x Seal
20.5 mm perflouroelastomer 04-6207
4 x Adaptors
Refer to seperate table
Holder
4 vial 60 ml flasks
04-6125
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 29
Aluminium Polypropylene Drying Adaptors
Type Vial Size Part number
AA
Maximum Ø 17.3 mm Length 48.5 to 51.5 mm 04-6156
AB
Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6155
AC
Maximum Ø 20.3 mm Length 48.5 to 51.5 mm 04-6166
AD
Maximum Ø 13.5 mm Length 38.5 to 41.5 mm 04-6174
AE
Maximum Ø 11.8 mm Length 30.5 to 33.5 mm 04-6214
AF Maximum Ø 15.3 mm Length 48.5 to 51.5 mm 04-4686
AG
Maximum Ø 11.8 mm Length 45.5 to 48.5 mm
04-6615
AH Maximum Ø 19.8 mm Lengh 38.5 to 41.5 mm 04-6619
Polypropelene Lyophilisation / Concentration Adaptors
Type Vial Size Part number
AA
Maximum Ø 17.3 mm Length 48.5 to 51.5 mm 04-6110
AB
Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6130
AC
Maximum Ø 20.3 mm Length 48.5 to 51.5 mm 04-6167
AD
Maximum Ø 13.5 mm Length 38.5 to 41.5 mm 04-6175
AE
Maximum Ø 11.8 mm Length 30.5 to 33.5 mm 04-6125
AF
Maximum Ø 15.3 mm Length 48.5 to 51.5 mm 04-4688
AG
Maximum Ø 11.8 mm Length 45.5 to 48.5 mm
04-6614
AH Maximum Ø 19.8 mm Lengh 38.5 to 41.5 mm 04-6618
Options and Accessory Brochure
30 10-1478 - Issue 4-15 September 2009
SampleGenie - 125 ml
Assembly Vial Size Quantity Part number
Range: Ø 11.8 to 28.3 mm Length 32 to 60 mm
2 70-1151
The SampleGenie assembly includes Flasks, Holder, Cushions and black viton seals. Due to the wide range of options, Adaptors must be specified separately. Alternative seal options (low leachable white viton or highly resistant FFKM perflouroelastomer) may also be specified at point of order.
Sub Assembly Parts
Description Specification Part number
2 x 125 ml Flask
Borosilicate glass 04-6047 25 mm Viton 04-6142 25 mm With Viton 04-6231
2 x Seal
25 mm Perflouroelastomer 04-6231
2 x Cushions
04-6595
2 x Adaptors
Refer to seperate table
Holder
2 vial 125 ml flasks
04-6188
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 31
Aluminium Polypropelene Drying Adaptors
Type Vial Size Part number
BA
Maximum Ø 27.3 mm Length 58.5 to 61.5 mm
04-6048
BB
Maximum Ø 16.8 mm Length 33.5 to 36.5 mm 04-6161
BC
Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6162
BD
Maximum Ø 28.3 mm Length 58.5 to 61.5 mm 04-6190
BE
Maximum Ø 11.8 mm Length 30.5 to 33.5 mm 04-6216
BF
Maximum Ø 17.3 mm Length 58.5 to 61.5 mm 04-6292
BG
Maximum Ø 15.3 mm Length 48.5 to 51.5 mm 04-6378
BH
Maximum Ø 17.3 mm Length 48.5 to 51.5 mm 04-6390
BJ
Maximum Ø 23.8 mm Length 58.5 to 61.5 mm 04-6454
BK
Maximum Ø 21.8 mm Length 55.5 to 58.5 mm 04-6606
Polypropelene Lyophilisation / Concentration Adaptors
Type Vial Size Part number
BA
Maximum Ø 27.3 mm Length 58.5 to 61.5 mm 04-6049
BB
Maximum Ø 16.8 mm Length 33.5 to 36.5 mm 04-6159
BC
Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6160
BD
Maximum Ø 28.3 mm Length 58.5 to 61.5 mm 04-6192
BE
Maximum Ø 11.8 mm Length 30.5 to 33.5 mm 04-6217
BF
Maximum Ø 17.3 mm Length 58.5 to 61.5 mm 04-6293
BG
Maximum Ø 15.3 mm Length 48.5 to 51.5 mm 04-6377
BH
Maximum Ø 17.3 mm Length 48.5 to 51.5 mm 04-6389
BJ
Maximum Ø 23.8 mm Length 58.5 to 61.5 mm 04-6453
BK
Maximum Ø 21.8 mm Length 55.5 to 58.5 mm 04-6605
Options and Accessory Brochure
32 10-1478 - Issue 4-15 September 2009
SampleGenie - 250 ml
Assembly Vial Size Quantity Part number
Range: Ø 11.8 to 28.3 mm Length 32 to 70 mm
1
70-1152
The SampleGenie assembly includes Flask, Holder, Cushion and black viton seal. Due to the wide range of options, Adaptors must be specified separately. Alternative seal options (low leachable white viton or highly resistant FFKM perflouroelastomer) may also be specified at point of order.
Sub Assembly Parts Description Specification Part number
250 ml Flask
Borosilicate glass 04-6140 25 mm Viton 04-6142 25 mm White Viton 04-6231
Seal
25 mm Perflouroelastomer 04-6208
Adapter
Refer to separate table
Cushion
04-6187
Holder
1 vial 250 ml flask 04-6141
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 33
Aluminium Polypropylene Drying Adaptors
Type Vial Size Part number
CA
Maximum Ø 27.3 mm Length 68.5 to 71.5 mm 04-6163
CB
Maximum Ø 28.3 mm Length 68.5 to 71.5 mm 04-6168
CC
Maximum Ø 27.3 mm Length 58.5 to 61.5 mm 04-6182
CD
Maximum Ø 17.3 mm Length 58.5 to 61.5 mm 04-6184
CE
Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6186
CF
Maximum Ø 11.8 mm Length 30.5 to 34.5 mm 04-6218
CG
Maximum Ø 28.3 mm Length 58.5 to 61.5 mm 04-6238
CH
Maximum Ø 21.3 mm Length 68.5 to 71.5 mm 04-6363
Polypropelene Lyophilisation / Concentration Adaptors
Type Vial Size Part number
CA
Maximum Ø 27.3 mm Length 68.5 to 71.5 mm 04-6144
CB
Maximum Ø 28.3 mm Length 68.5 to 71.5 mm 04-6169
CC
Maximum Ø 27.3 mm Length 58.5 to 61.5 mm 04-6170
CD
Maximum Ø 17.3 mm Length 58.5 to 61.5 mm 04-6171
CE
Maximum Ø 15.3 mm Length 43.5 to 46.5 mm 04-6172
CF
Maximum Ø 11.8 mm Length 30.5 to 34.5 mm 04-6219
CG
Maximum Ø 28.3 mm Length 58.5 to 61.5 mm 04-6239
CH
Maximum Ø 21.3 mm Length 68.5 to 71.5 mm 04-6245
Options and Accessory Brochure
34 10-1478 - Issue 4-15 September 2009
Thermal Cushion
Description
Quantity Part number
For use with 25 ml Flask
(Pack of 96) 10-1551
Ex-Stock
For use with 50 ml Flask
(Pack of 96) 10-1556
Ex-Stock
For use with 100 ml Flask
(Pack of 48) 10-1555
Ex-Stock
For use with 170 / 250 ml Flask
(Pack of 48) 10-1554
Ex-Stock
For use with 250 ml Flask
(Pack of 12) 10-1553
Ex-Stock
For use with 500 ml Flask
(Pack of 12) 10-1552
Ex-Stock
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 35
Notes
Options and Accessory Brochure
36 10-1478 - Issue 4-15 September 2009
Sample Holder Part Number Index 10-5000............... 10 10-5025............... 10 10-5047............... 10 10-5001............... 10 10-5002............... 11 10-5003............... 11 10-5046............... 11 10-5008............... 11 10-5048............... 11 10-5004............... 12 10-5005............... 12 10-5042............... 12 10-1005............... 12 10-5006............... 12 10-5009............... 13 10-5044............... 13 10-5045............... 14 10-5029............... 14 10-5032............... 14 10-5024............... 14 10-5034............... 14 10-5035............... 15 10-5016............... 15 10-5037............... 15 10-5021............... 15 10-5038............... 15 10-5067............... 16 10-5028............... 16 10-5007............... 16 10-5030............... 17
10-5031 ...............17 10-5033 ...............18 10-5036 ...............18 10-5040 ...............18 10-5039 ...............18 10-5041 ...............18 10-5062 ...............19 10-5019 ...............19 10-5014 ...............19 10-5013 ...............19 10-5010 ...............20 10-5068 ...............20 70-0057 ...............21 70-0009 ...............21 70-0058 ...............21 70-0774 ...............21 10-5049 ...............22 10-5043 ...............22 10-5011 ...............22 10-5058 ...............22 10-5059 ...............22 10-5027 ...............23 10-5020 ...............23 10-5017 ...............23 10-5050 ...............24 10-5022 ...............24 10-5055 ...............24 10-5015 ...............24 10-5052 ...............24 10-5064 ...............24
70-0538............... 25 70-0539............... 25 70-0656............... 25 70-1026............... 25 70-0657............... 25 70-0579............... 25 70-0658............... 25 70-0581............... 26 70-0705............... 26 70-0706............... 26 70-1021............... 26 70-0580............... 26 70-0582............... 27 10-1616............... 27 10-5017............... 28 70-1031............... 28 10-6068............... 28 70-0924............... 28 10-5065............... 29 10-5053............... 29 10-5054............... 29 70-1004............... 30 70-1025............... 31 10-5060............... 31 10-5063............... 31 10-5061............... 31 70-0716............... 32
Options and Accessory Brochure
10-1478 - Issue 4-15 September 2009 37
Sample Holder Part Number Cross Reference
Old New
............... 10-1616 70-0005............... 10-5037 70-0007............... 10-5035 70-0008............... 10-5049 70-0019............... 10-5024 70-0024............... 10-5031 70-0052............... 10-5043 70-0055............... 10-5019 70-0072............... 10-5028 70-0073............... 10-5029 70-0538............... 70-0539............... 70-0550............... 10-5053 70-0551............... 10-5054 70-0579...............
Old New 70-0580 ............... 70-0582 ............... 70-0633 ............... 10-5014 70-0646 ............... 10-5051 70-0656 ............... 70-0657 ............... 70-0660 ............... 10-5025 70-0661 ............... 10-5001 70-0663 ............... 10-5002 70-0665 ............... 10-5004 70-0666 ............... 10-5006 70-0667 .............. 10-5027 70-0668 ............... 10-5015 70-0669 ............... 10-5023 70-0670 ............... 10-5026 70-0671 ............... 10-5027
Old New 70-0673 ............... 10-5034 70-0674 ............... 10-5038 70-0675 ............... 10-5030 70-0676 ............... 10-5013 70-0719 ............... 10-5036 70-0720 ............... 10-5009 70-0724 ............... 10-5010 70-0759 ............... 10-5040 70-0777 ............... 10-5005 70-0778 ............... 10-5022 70-0780 ............... 10-5020 70-0794 ............... 10-5050 70-0928 ............... 10-5042 ................ 10-5017 70-1025 ............... ................ 10-5060
Swing Part Number Cross Reference
Old New
70-0001............... 70-0959 70-0091............... 70-0578 70-0093............... 70-0578 70-0110............... 70-0578 70-0354............... 70-0959 70-0620............... 70-0959
Amendment Control Form
Issue Reason for Change Date Issued
1 Introduction of 500ml Flask Holder for HT Series II 30-Nov-05 2 Corrected image for 10-5042 31-Jul-06 3 Introduction of Schott Bottle & Beaker holders 13-Nov-06 4 Waters Fraction Collection Rack – Options updated 20-Aug-07 5 Addition of tube holder 10-5000 31-Jan-08 6 Addition of Maintenance of Sample Holder 17-Apr-08
4-7 Update U.S. address 24-Oct-08 4-8 Amend layout 16-Jan-09 4-9 Correct title Centrifuge Tube Holder Options – Swing 27-Jan-09 4-10 Update Sample Holder Part number Index 16-Feb-09 4-11 Remove Mega Sample Holders 26-Feb-09 4-12 Introduced sampleGenie and updated list of holders 27-Aug-09 4-13 Added SampleGenie vial adaptors AG and AH 1-Sep-09 4-14 Added Swing/Holder type, amend 10-5063 compatibility 16-Sep-09
4-15 Added Glassware Labels, Compatibility with other Manufacturers, added Waters Collection Rack illustrations, removed various special holders.
23-Sep-09
Genevac Limited The Sovereign Centre
Farthing Road Ipswich IP1 5AP
United Kingdom
Sales and Service Hotlines
Service Hotline: +44 (0) 1473 243000
Sales Hotline: +44 (0) 1473 240000
Fax: +44 (0) 1473 461176
Email: mailto:[email protected]
Web site: http://www.genevac.com
Genevac Inc SP Industries
815 State Route 208 Gardiner
NY, 12525 United States of America
Sales and Service Hotline
(1) 845 267 2212
Fax (1) 845 267 2212
Email: [email protected]
Genevac Technology is protected by patents and patent applications in the UK and worldwide. Genevac Ltd has a continuous development programme aimed at further improving their products and all specifications are, therefore, subject to change. Coolheat®, VacRampTM (Dri-Pure®), SampleGuardTM and associated logos are trade marks of