geotechnical site investigation · 2020. 5. 18. · varies shale, el (class v) 400 60 700 varies...

70
1 GEOTECHNICAL INVESTIGATION REPORT LOT 30, SOUTH STREET MARSDEN PARK GEOTESTA PTY LTD | ABN 91851620815 | 6/31-37 Howleys Road, Notting Hill VIC 3168 Phone: 1300 852216 | Fax: 03 9562 9098 | email: [email protected] CLIENT : UNIVERSAL PROPERTY GROUP REPORT No. : NE004-16 - Geotechnical Investigation DATE : 04 April 2016

Upload: others

Post on 01-Feb-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

  • 1

    GEOTECHNICAL INVESTIGATION REPORT

    LOT 30, SOUTH STREET MARSDEN PARK

    GEOTESTA PTY LTD | ABN 91851620815 | 6/31-37 Howleys Road, Notting Hill VIC 3168

    Phone: 1300 852216 | Fax: 03 9562 9098 | email: [email protected]

    CLIENT : UNIVERSAL PROPERTY GROUP

    REPORT No. : NE004-16 - Geotechnical Investigation

    DATE : 04 April 2016

  • Lot 30, South Street, Marsden Park NE004-16

    2

    EXECUTIVE SUMMARY

    A geotechnical investigation was conducted by Geotesta for the proposed residential

    development at Lot 30 South Street, Marsden Park on 26 February 2016. The aim of the

    geotechnical investigation is to provide geotechnical design parameters for the

    proposed multi-level (up to 6 level) residential buildings with basement.

    The report provides information on the subsurface soil profile, site classification,

    suitable foundation systems and founding depths, retaining wall design parameters

    and recommendations for earthworks.

  • Lot 30, South Street, Marsden Park NE004-16

    3

    TABLE OF CONTENT

    1. INTRODUCTION ................................................................................................................................ 4

    2. FIELD INVESTIGATION .................................................................................................................... 5

    3. FINDINGS ............................................................................................................................................. 7

    3.1 Site Condition .................................................................................................................................. 7

    3.2 Site Geology ..................................................................................................................................... 7

    3.3 Generalised Soil Profile .................................................................................................................. 7

    3.4 Site Classification............................................................................................................................. 8

    3.5 Laboratory Test ................................................................................................................................ 9

    4. FOUNDATION RECOMMENDATIONS....................................................................................... 11

    4.1 Pad Footing System ....................................................................................................................... 11

    4.1 Bored Pier Footing System ........................................................................................................... 11

    5. EARTH WORKS ................................................................................................................................. 13

    5.1 Site Stripping & Clearing ............................................................................................................. 13

    5.2 Earthworks ..................................................................................................................................... 13

    5.3 Drainage of Retention Systems ................................................................................................... 13

    5.4 Erosion and sediment control ...................................................................................................... 13

    5.5 Open Cut Excavation .................................................................................................................... 14

    5.6 Select Fill Material ......................................................................................................................... 14

    5.7 Compaction Requirements .......................................................................................................... 14

    5.8 Retaining Wall ............................................................................................................................... 15

    5.9 Pavement Subgrade Preparation (Driveways and Car parks) ................................................ 15

    5.10 Construction Works .................................................................................................................... 15

    Appendix A Test Pit and Borehole Logs

    Appendix B Laboratory Test Results

    Appendix C Core and Test Pit Photos

  • Lot 30, South Street, Marsden Park NE004-16

    4

    1. INTRODUCTION Geotesta undertook a geotechnical investigation for the proposed multi-level

    residential development at Lot 30 South Street, Marsden Park on 26 February 2016.

    This geotechnical investigation work was authorised by Universal Property Group.

    This report presents the geotechnical investigation results including subgrade

    conditions, subsurface soil profile, in-situ testing results, recommendations on the

    design of suitable footing systems and founding depths and retaining wall design

    parameters.

  • Lot 30, South Street, Marsden Park NE004-16

    5

    2. FIELD INVESTIGATION

    The investigation involved the drilling of 3 boreholes and 12 test pits in the area of the

    proposed development. A site sketch showing the approximate borehole locations is

    presented in Figure 1. The field investigation was carried out on 26 February 2016.

    Figure 1: Site Plan and Borehole Locations

    The boreholes were drilled to a maximum depth of 10.0m. Boreholes drilling was

    undertaken using a track mounted Comacchio Geo 205 drilling rig. Standard

    Penetration Test (SPT) was undertaken in the soil profile in each borehole at every 1.5m

    depth interval. Rock coring was undertaken in rock formation.

  • Lot 30, South Street, Marsden Park NE004-16

    6

    The test pits were excavated to a depth of 2.5m to 3.0m. Test pit excavation was

    undertaken using a 5 ton Yanmar Excavator.

    The soil profile encountered in the boreholes was logged by a Geotesta Geotechnical

    Engineer in accordance with AS 1726-1993. All field observations are presented on the

    borehole logs attached in Appendix A. Selected representative samples were sent to the

    Geotesta NATA accredited laboratory for testing of appropriate index properties.

  • Lot 30, South Street, Marsden Park NE004-16

    7

    3. FINDINGS

    3.1 Site Condition

    The site is a farmland situated to the south of South Street in Marsden Park. The site is

    gently sloping towards the north. The property covers an area of approximately 11.5

    hectares and is currently an open paddock with scattered trees across the majority of

    the site and denser tree cover in the southern section of the site. A farm dam is located

    in the northern corner of the property.

    3.2 Site Geology

    The geological origin of the soil profile was identified from our visual examination of

    the soil samples, geotechnical experience, and reference to geological maps of the area.

    The geological map of the area indicates that the site is underlain by Wianamatta

    Group sandstone and shales (Geology Map of Sydney, 1:100,000 scale) with presence of

    residual soil in the upper layers. Bringelly Shale of Wianamatta Group consists of shale,

    carbonaceous claystone, claystone, laminated fine to medium grained lithic sandstone

    and rare coal or tuff.

    Figure 2: Geology Map of the Site

    3.3 Soil Profile

    The soil profile at the test locations is presented in the borehole logs in Appendix A.

    The underlying subsurface soil profile as encountered in boreholes generally consisted

  • Lot 30, South Street, Marsden Park NE004-16

    8

    of thin layer of silty sand topsoil overlying firm clay that grades to hard clay which

    overlies moderately to slightly weathered shale. The test pit excavations revealed no

    presence of groundwater to the end of the test pit excavation except in test pit TP7

    where perched groundwater was intersected at 2.4m depth.

    The subsurface soil profile are detailed in the following table.

    Table 1: Subsurface Soil Profile

    Borehole

    no.

    Depth

    (m)

    Soil/Rock

    Type

    Consistency/

    Relative density/

    Strength

    Undrained

    Shear Strength,

    Su (kPa)

    TP1-TP12 0.0-0.05 Silty Sand Medium dense -

    0.05-1.0 Clay Firm 40

    1.0-2.0 Clay Stiff 80

    2.0-2.5 Clay Very Stiff 150

    BH1 0.0-0.05 Silty Sand Medium dense -

    0.05-1.0 Clay Firm 40

    1.0-2.2 Clay Stiff 80

    2.2-5.5 Clay/XW Shale Very stiff to hard 200-300

    5.5-6.0 HW Shale (Class V) Extremely Low 400

    6.0-9.0 MW Shale (Class IV) Very Low - Low 800

    9.0-10.5 SW Shale (Class III) Low - Medium 1500

    BH2 0.0-0.05 Silty Sand Medium dense -

    0.05-1.4 Clay Firm 35

    1.4-3.0 Clay Stiff 70

    3.0-5.0

    Clay/XW Shale Very stiff to hard 100-300

    5.0-7.9 HW Shale (Class V) Extremely Low 400

    7.9-9.0 MW Shale(Class IV) Very Low - Low 800

    Groundwater was not encountered in any of the boreholes during our investigation.

    3.4 Site Classification

    After considering the area geology, the soil profile encountered in the bores and the

    climatic zone of the area (zone 2); the site is classified as CLASS H1, with respect to

    foundation construction (Australian Standard 2870-2011 Residential Slabs and

    Footings).

  • Lot 30, South Street, Marsden Park NE004-16

    9

    It has been estimated that the Characteristic Surface Movement (ys) of the underlying

    natural soil material will be in the range of 40mm to 60mm provided the building site is

    protected from “abnormal moisture conditions” and is drained as described in AS 2870.

    It must be emphasized that the heave mentioned and recommendations referred to in

    this report are based solely on the observed soil profile observed at the time of the

    investigation for this report, without taking into account any abnormal moisture

    conditions as defined in AS2870 – 2011, Clause 1.3.3 that might be created thereafter.

    With abnormal moisture conditions, distresses will occur and may result in “non-

    acceptable probabilities of serviceability and safety of the building during its design

    life”, as defined in AS2870-2011, Clause 1.3.1.

    3.5 Laboratory Test

    Representative subgrade samples were sent to a Geotesta NATA accredited laboratory

    for testing of appropriate index properties. The laboratory test results are summarized

    in Table 2:

    Table 2: Summary of Laboratory Test Results

    Bore

    No.

    Depth

    (m) Soil Type

    Wn

    %

    LL

    %

    PI

    %

    LS

    %

    BH1 0.5 Clay 19.7 54 36 13

    BH2 1.5 Clay 21.2 - - -

    BH2 3.0 Clay 19.5 83 59 16

    TP4 2.5 Clay 19.8 - - -

    TP9 0.7 Clay 19.6 66 45 16

    TP11 1.2 Clay 24.4 - - - Note: Wn= Moisture content; LL= Liquid Limit; PI= Plasticity Index; LS= Linear Shrinkage;

    Table 3: Summary of Rock Laboratory Test Results

    Bore No. Depth (m) Test Type Rock Type Point Load Is50

    (MPa)

    UCS

    (MPa)

    BH1 6.0-6.15 Diametral Shale 0.02 0.20

    BH2 8.9-9.1 Diametral Shale 0.11 1.00

    Table 4 below presents the results of the aggressivity tests on soils concerning concrete

    piles.

  • Lot 30, South Street, Marsden Park NE004-16

    10

    Table 4: Summary of Environmental Laboratory Test Results

    Bore No. Depth (m) Soil Type pH SO4

    TP03 1.5 CLAY 4.9 530

    TP06 2.5 CLAY 4.8 380

    TP08 1.0 CLAY 5.0 240

    TP10 1.0 CLAY 4.8 240

    TP12 1.7 CLAY 4.8 350

    BH02 0.5 CLAY 4.9 290

    BH03 4.0 SHALE 6.9 260

    The test results indicates the soils are non-aggressive for construction of concrete piles.

  • Lot 30, South Street, Marsden Park NE004-16

    11

    4. FOUNDATION RECOMMENDATIONS

    The proposed multi-level residential buildings associated with the subject development

    can be founded on pad footings or bored piers/screw piles.

    4.1 Pad Footing System

    The proposed multi-level residential buildings can be founded on pad footings

    founded into the underlying natural stiff to hard clay/weathered Shale. The footings

    can be designed using the following parameters:

    Table 5: Allowable bearing capacity

    Borehole/Test

    Pit nos.

    Allowable Bearing

    Capacity (kPa)

    Founding Material

    TP1 to TP12

    75kPa Clay, 0.5m-1.0m

    150kPa Clay, 1.0m-2.0m

    250kPa Clay, 2.0m-2.5m

    BH1

    75kPa Clay, 0.5-1.0m

    150kPa Clay, 1.0m-2.2m

    350kPa Clay/EW Rock, 2.2m-5.5m

    750kPa Shale, Extremely Low Strength (Class V/IV)

    1500kPa Shale, Very Low Strength (Class IV or better)

    BH2

    75kPa Clay, 0.5-1.5m

    150kPa Clay, 1.5m-3.0m

    350kPa Clay/EW Rock, 3.0m-4.9m

    750kPa Shale, Extremely Low Strength (Class V/IV)

    1500kPa Shale, Very Low Strength (Class IV or better)

    4.1 Bored Pier Footing System

    Bored piles can be used to support the proposed multi-level development. We

    recommend that the designing engineer refer to AS2870 - 2011 to ensure design

    compliance to this document, especially Sections 1.3 “Performance of Footing Systems”

    and “Design Considerations”.

    The carrying capacity of bored piles can be estimated using the following parameters:

  • Lot 30, South Street, Marsden Park NE004-16

    12

    Table 6: Pile Design Parameter

    Depth

    (m)

    Soil/Rock Type Undrained Shear

    Strength

    (kPa)

    Design Unit Skin

    Friction

    (kPa)

    Design Unit End

    Bearing Capacity

    (kPa)

    0.0-1.5 Clay (Firm) 50 5 -

    1.5-2.0 Clay (Stiff) 75 12 -

    2.0-5.5 Clay (Hard) 200 30 400

    Varies Shale, EL (Class V) 400 60 700

    Varies Shale, VL (Class IV) 800 120 1000

    Varies Shale, L-M (Class III) 1500 225 3500

    It should be noted that the soil profile may vary across the site. The foundation depths

    quoted in this report are measured from the surface during our testing and may vary

    accordingly if any filling or excavation works are carried out. It is recommended that a

    geotechnical engineer be engaged during footing excavation stage to confirm the

    founding depth and founding material.

  • Lot 30, South Street, Marsden Park NE004-16

    13

    5. EARTH WORKS

    5.1 Site Stripping & Clearing

    Unless otherwise specified, grass, uncontrolled fill material, clayey silt and other

    unsuitable materials shall be removed from the site. All trees and stumps are to be

    similarly removed, such areas backfilled and compacted as per Australian Standards

    AS3798-2007, Guideline earthworks for commercial and residential developments.

    5.2 Earthworks

    Where it is necessary to raise the levels of all or part of the subdivision area, such filled

    material should be free of organic and/or unsuitable material and shall be placed in

    layers not exceeding 250mm in depth. Each layer will be suitably compacted prior to

    the laying of the next layer, to a minimum 95% of maximum dry density of standard

    compaction. The water content of the fill should be reduced by aeration or increased by

    adding water as necessary to achieve this required compaction.

    5.3 Drainage of Retention Systems

    As seepage infiltration from perched groundwater table is quite likely to be present in

    the zones of influence during wet season, it is recommended that a suitable drainage

    system be installed and maintained behind all retaining wall structures to ensure the

    dissipation of any hydrostatic forces which may result from the accumulation of any

    seepage water behind the wall structures. Such seepage water flows should readily be

    able to be intercepted by the construction of a suitable sub-surface cut-off drain on the

    high side of the subject site.

    5.4 Erosion and sediment control

    Erosion and Sediment control plan should be implemented before commencing any

    earthworks for the proposed development. Below are some general guidelines to be

    taken into considerations:

    Establish a single entry/exit point when construction work starts

    Minimized area to be cleared and provide as much as vegetation as possible

    Install sediment fences along the low side of the site before work begins

    Ensure the imported fill material/top soil within the sediment controlled plan

    Fill in and compact all trenches immediately after services have been laid

    Divert water around the work site and stabilized channels

  • Lot 30, South Street, Marsden Park NE004-16

    14

    A silt trap to be installed around the site perimeter during construction.

    Provide temporary earth drain around the proposed site if possible to prevent

    water logging within the site Stabilized exposed earth banks/embankment

    5.5 Open Cut Excavation

    Excavation in the natural stiff to very stiff clay can be undertaken to 1.5m depth

    without battering back the sides of the trench. If the open trenches exceed 1.5m in

    depth, progressive shielding should be used. Alternatively, the trenches should be

    battered back at 2H:1V.

    Temporary excavation into the compacted clay fill material can be undertaken in a

    similar manner to that used for the natural soil.

    The temporary excavation batter in sandy or gravelly soil/fill should be no steeper than

    1H:1V.

    A suitable dewatering system (spears or sump pump) may be required to pump

    groundwater in the event that the groundwater is encountered above the excavation

    zone. Although groundwater was not encountered in any boreholes during the

    geotechnical investigation, the presence of possible perched groundwater resulted

    from infiltration of surface run-off should not be dismissed.

    5.6 Select Fill Material

    Select fill material should have little volume change with changes in moisture content.

    Suitable material types of low reactivity, including sandy clay, silty clay, clayey sand,

    silty sand and highly to moderately weathered siltstone and sandstone. The select fill

    should be well graded with a maximum particle size of not more than 40mm.

    5.7 Compaction Requirements

    Compaction of both backfill material and embedment material is required to ensure

    that excessive surface settlement does not occur. The required backfill density and

    minimum frequency of testing for compaction control as detailed in AS 3798-2007 are

    summarized below:

    - 1 test per layer per material type per 2500 m2.

    - 1 test per 500 m3 distributed evenly throughout full depth and area.

    - 3 tests per site.

  • Lot 30, South Street, Marsden Park NE004-16

    15

    Testing should be undertaken in accordance with AS 1289.5. Tested layers that do not

    satisfy the outlined criteria shall be stripped, replaced, recompacted and retested to

    achieve the minimum compaction requirement mentioned above.

    Testing of compaction density should be undertaken by a suitably qualified

    geotechnical testing company. Representative samples of the controlled fill should be

    regularly tested.

    5.8 Retaining Wall

    The lateral earth pressure acting on any proposed retaining wall can be estimated by

    using the following soil parameters:

    Table 7: Retaining Wall Parameters

    Depth

    (m)

    Soil/Rock Type Unit

    Weight

    (kN/m3)

    Su (kPa) c’ (kPa) Ф’ (deg)

    0.0-1.5 Clay (Firm) 18 50 5 23

    1.5-2.0 Clay (Stiff) 18 75 10 25

    2.0-5.5 Clay (Hard) 19 200 30 25

    Varies Shale, EL (Class V) 21 400 50 30

    Varies Shale, VL (Class IV) 22 800 100 35

    Note: Su= undrained shear strength; c’=effective cohesion; ’=effective angle of friction

    5.9 Pavement Subgrade Preparation (Driveways and Car parks)

    It is recommended that any uncontrolled fill material or soft spots encountered in the

    proposed subgrade be removed to reveal firm ground. The removed section of the

    subgrade shall be backfilled with site derived clay material compacted to at least 95%

    of maximum dry density of standard compaction (AS 1289.5.1.1) with moisture

    condition at the equilibrium moisture content or -1% to +3% of the optimum. Proof

    rolling of the subgrade level should then be undertaken to reveal any soft spots prior to

    placement of the pavement materials.

    5.10 Construction Works

    It is recommended that Geotesta be engaged to provide a site inspection during the

    early stage of construction to confirm that the ground conditions of the subgrade along

    the proposed road construction are consistent with the assumptions or findings in this

    report.

  • Lot 30, South Street, Marsden Park NE004-16

    16

    Should you require any further information regarding this report, please do not

    hesitate to contact the undersigned.

  • Lot 30, South Street, Marsden Park NE004-16

    17

    Information about This Report

    The report contains the results of a geotechnical investigation conducted for a specific purpose and

    client. The results should not be used by other parties, or for other purposes, as they may contain neither

    adequate nor appropriate information. In particular, the investigation does not cover contamination

    issues unless specifically required to do so by the client.

    Test Hole Logging

    The information on the test hole logs (boreholes, test pits, exposures etc.) is based on a visual and tactile

    assessment, except at the discrete locations where test information is available (field and/or laboratory

    results). The test hole logs include both factual data and inferred information.

    Groundwater

    Unless otherwise indicated, the water levels presented on the test hole logs are the levels of free water or

    seepage in the test hole recorded at the given time of measuring. The actual groundwater level may

    differ from this recorded level depending on material permeability (i.e. depending on response time of

    the measuring instrument). Further, variations of this level could occur with time due to such effects as

    seasonal, environmental and tidal fluctuations or construction activities. Confirmation of groundwater

    levels, phreatic surfaces or piezometric pressures can only be made by appropriate instrumentation

    techniques and monitoring programmes.

    Interpretation of Results

    The discussion or recommendations contained within this report normally are based on a site evaluation

    from discrete test hole data. Generalized, idealized or inferred subsurface conditions (including any

    geotechnical cross-sections) have been assumed or prepared by interpolation and/or extrapolation of

    these data. As such these conditions are an interpretation and must be considered as a guide only.

    Change in Conditions

    Local variations or anomalies in the generalized ground conditions do occur in the natural environment,

    particularly between discrete test hole locations. Additionally, certain design or construction procedures

    may have been assumed in assessing the soil-structure interaction behaviour of the site. Furthermore,

    conditions may change at the site from those encountered at the time of the geotechnical investigation

    through construction activities and constantly changing natural forces.

    Any change in design, in construction methods, or in ground conditions as noted during construction,

    from those assumed or reported should be referred to GEOTESTA for appropriate assessment and

    comment.

    Geotechnical Verification

    Verification of the geotechnical assumptions and/or model is an integral part of the design process -

    investigation, construction verification, and performance monitoring. Variability is a feature of the

    natural environment and, in many instances, verification of soil or rock quality, or foundation levels, is

    required. There may be a requirement to extend foundation depths, to modify a foundation system or to

    conduct monitoring as a result of this natural variability. Allowance for verification by geotechnical

    personnel accordingly should be recognized and programmed during construction.

    Reproduction of Reports

    Where it is desired to reproduce the information contained in our geotechnical report, or other technical

    information, for the inclusion in contract documents or engineering specification of the subject

    development, such reproductions should include at least all of the relevant test hole and test data,

    together with the appropriate standard description sheets and remarks made in the written report of a

    factual or descriptive nature. Reports are the subject of copyright and shall not be reproduced either

    totally or in part without the express permission of Geotesta.

  • Lot 30, South Street, Marsden Park NE004-16

    18

    APPENDIX A

    BORE HOLE AND TEST PIT LOGS

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    No groundwater encountered

    M

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    Consi

    stency

    / De

    nsity

    -33.709884Marsden Park 500mm

    FIELD TESTS& NOTES

    150.827027

    Water

    Level

    s

    SD

    Samp

    ling / R

    uns

    1.50

    2.00

    2.50

    Moistu

    re

    AF

    Dynam

    ic Cone

    Blows

    per 1

    00 mm

    DCP e

    stimate

    dCB

    R

    4.00

    0.00

    1.00

    0.50

    3.00

    3.50

    2.50

    3.50

    3.00

    4.00

    grades very stiff

    Test Pit Terminated at 3.0m

    Depth

    (m)

    Drillin

    g Meth

    od

    SMCH

    Art-con CivilSteveYanmar

    Universal Property GroupLot 30 South St Marsden Park NSWNE004-16

    0.00

    0.50

    1.50

    2.00

    1.00

    26/2/2016

    grades grey mottled orange

    CLAY, grey mottled orange

    Silty SAND, brown, medium grainedCLAY, red brown mottled greymoist, firm

    T

    Graphi

    c Log

    Group

    Symb

    ol

    intact tube sample

    CL

    DF

    moist stiffSt

    VSt

    GEOTESTA PTY LTD

    TEST PIT LOG PIT No TP1

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    No groundwater encountered

    M

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    4.00

    GEOTESTA PTY LTD

    4.00

    T intact tube sample

    3.50 3.50

    3.003.00

    2.50

    Test Pit Terminated at 2.5m

    grades very stiff VSt

    2.50

    2.002.00

    1.501.50

    1.00CL CLAY, grey mottled orange St

    moist, stiff1.00

    moist, firm0.50 0.50

    grades grey mottled orange

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    Moistu

    reCo

    nsiste

    ncy /

    Densi

    tyDy

    namic C

    oneBlo

    ws pe

    r 100

    mmDC

    P estim

    ated

    CBR

    Samp

    ling / R

    unsWa

    ter Le

    velsFIELD TESTS

    & NOTES

    0.00 SM Silty SAND, brown, medium grained D 0.00CH CLAY, red brown mottled grey F

    Lot 30 South St Marsden Park NSW Steve -33.710513NE004-16 YanmarMarsden Park 500mm26/2/2016 AF SD

    TEST PIT LOG PIT No TP2Universal Property Group Art-con Civil 150.827007

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    No groundwater encountered

    M

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    intact tube sample

    4.00

    3.50

    GEOTESTA PTY LTD

    4.00

    T

    3.50

    3.003.00

    Test Pit Terminated at 2.6m2.502.50

    2.00grades very stiff VSt

    2.00

    1.50CL CLAY, grey mottled orange St

    moist, stiff1.50

    1.001.00

    moist, firm0.50 0.50

    grades grey mottled orange

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    Moistu

    reCo

    nsiste

    ncy /

    Densi

    tyDy

    namic C

    oneBlo

    ws pe

    r 100

    mmDC

    P estim

    ated

    CBR

    Samp

    ling / R

    unsWa

    ter Le

    velsFIELD TESTS

    & NOTES

    0.00 SM Silty SAND, brown, medium grained D 0.00CH CLAY, red brown mottled grey F

    Lot 30 South St Marsden Park NSW Steve -33.709884NE004-16 YanmarMarsden Park 500mm26/2/2016 AF SD

    TEST PIT LOG PIT No TP3Universal Property Group Art-con Civil 150.827027

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    No groundwater encountered

    M

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    3.50

    4.00

    T intact tube sampleGEOTESTA PTY LTD

    4.00

    3.50

    3.00 3.00

    2.50Test Pit Terminated at 2.5m

    grades very stiff VSt

    2.50

    2.002.00

    1.501.50

    1.00CL CLAY, grey mottled orange St

    moist, stiff1.00

    moist, firm0.50 0.50

    grades grey mottled orange

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    Moistu

    reCo

    nsiste

    ncy /

    Densi

    tyDy

    namic C

    oneBlo

    ws pe

    r 100

    mmDC

    P estim

    ated

    CBR

    Samp

    ling / R

    unsWa

    ter Le

    velsFIELD TESTS

    & NOTES

    0.00 SM Silty SAND, brown, medium grained D 0.00CH CLAY, red brown mottled grey F

    Lot 30 South St Marsden Park NSW Steve -33.711998NE004-16 YanmarMarsden Park 500mm26/2/2016 AF SD

    TEST PIT LOG PIT No TP4Universal Property Group Art-con Civil 150.827802

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    No groundwater encountered

    M

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    4.00

    GEOTESTA PTY LTD

    4.00

    T intact tube sample

    3.50 3.50

    3.003.00

    2.50

    Test Pit Terminated at 2.5mgrades with some clay

    2.50

    2.002.00

    1.501.50

    1.00SM Silty SAND, grey mottled orange, moist, medium dense MD

    with some rock fragments1.00

    moist, firm0.50 0.50

    grades grey mottled orange

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    Moistu

    reCo

    nsiste

    ncy /

    Densi

    tyDy

    namic C

    oneBlo

    ws pe

    r 100

    mmDC

    P estim

    ated

    CBR

    Samp

    ling / R

    unsWa

    ter Le

    velsFIELD TESTS

    & NOTES

    0.00 SM Silty SAND, brown, medium grained D 0.00CH CLAY, red brown mottled grey F

    Lot 30 South St Marsden Park NSW Steve -33.711415NE004-16 YanmarMarsden Park 500mm26/2/2016 AF SD

    TEST PIT LOG PIT No TP5Universal Property Group Art-con Civil 150.828284

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    No groundwater encountered

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    4.00

    GEOTESTA PTY LTD

    4.00

    T intact tube sample

    3.50 3.50

    3.003.00

    2.50

    Test Pit Terminated at 2.5m2.50

    2.002.00

    1.50grades very stiff VSt

    1.50

    1.001.00

    moist, firm0.50 0.50

    grades grey mottled orange, stiff St

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    Moistu

    reCo

    nsiste

    ncy /

    Densi

    tyDy

    namic C

    oneBlo

    ws pe

    r 100

    mmDC

    P estim

    ated

    CBR

    Samp

    ling / R

    unsWa

    ter Le

    velsFIELD TESTS

    & NOTES

    0.00 SM Silty SAND, brown, medium grained D 0.00CH CLAY, red brown mottled grey F

    Lot 30 South St Marsden Park NSW Steve -33.710907NE004-16 YanmarMarsden Park 500mm26/2/2016 AF SD

    TEST PIT LOG PIT No TP6Universal Property Group Art-con Civil 150.82816

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    M

    perched groundwater at 2.4m

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    4.00

    GEOTESTA PTY LTD

    4.00

    T intact tube sample

    3.50 3.50

    3.003.00

    2.50

    Test Pit Terminated at 2.5m2.50

    2.002.00

    1.501.50

    1.001.00

    CL CLAY, grey mottled orange VStmoist, very stiff

    moist, firm0.50 0.50

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    Moistu

    reCo

    nsiste

    ncy /

    Densi

    tyDy

    namic C

    oneBlo

    ws pe

    r 100

    mmDC

    P estim

    ated

    CBR

    Samp

    ling / R

    unsWa

    ter Le

    velsFIELD TESTS

    & NOTES

    0.00 SM Silty SAND, brown, medium grained D 0.00CH CLAY, red brown mottled grey F

    Lot 30 South St Marsden Park NSW Steve -33.710136NE004-16 YanmarMarsden Park 500mm26/2/2016 AF SD

    TEST PIT LOG PIT No TP7

    Universal Property Group Art-con Civil 150.828224

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    No groundwater encountered

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    4.00

    GEOTESTA PTY LTD

    4.00

    T intact tube sample

    3.50 3.50

    3.003.00

    2.50

    Test Pit Terminated at 2.5m2.50

    2.002.00

    1.50

    very stiff

    1.50

    1.001.00grades grey mottled orange, rock fragments in clay matrix VSt

    moist, firm0.50 0.50

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    Moistu

    reCo

    nsiste

    ncy /

    Densi

    tyDy

    namic C

    oneBlo

    ws pe

    r 100

    mmDC

    P estim

    ated

    CBR

    Samp

    ling / R

    unsWa

    ter Le

    velsFIELD TESTS

    & NOTES

    0.00 SM Silty SAND, brown, medium grained D 0.00CH CLAY, red brown mottled grey F

    Lot 30 South St Marsden Park NSW Steve -33.709523NE004-16 YanmarMarsden Park 500mm26/2/2016 AF SD

    TEST PIT LOG PIT No TP8Universal Property Group Art-con Civil 150.827912

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    No groundwater encountered

    M

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    4.00

    GEOTESTA PTY LTD

    4.00

    T intact tube sample

    3.50 3.50

    3.003.00

    2.50

    Test Pit Terminated at 2.5m2.50

    2.002.00

    1.501.50

    1.00very stiff

    1.00 grades grey mottled orange, rock fragments in clay matrix VSt

    moist, firm0.50 0.50

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    Moistu

    reCo

    nsiste

    ncy /

    Densi

    tyDy

    namic C

    oneBlo

    ws pe

    r 100

    mmDC

    P estim

    ated

    CBR

    Samp

    ling / R

    unsWa

    ter Le

    velsFIELD TESTS

    & NOTES

    0.00 SM Silty SAND, brown, medium grained D 0.00CH CLAY, red brown mottled grey F

    Lot 30 South St Marsden Park NSW Steve -33.709609NE004-16 YanmarMarsden Park 500mm26/2/2016 AF SD

    TEST PIT LOG PIT No TP9

    Universal Property Group Art-con Civil 150.828632

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    No groundwater encountered

    M

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    4.00

    GEOTESTA PTY LTD

    4.00

    T intact tube sample

    3.50 3.50

    3.003.00

    2.50

    Test Pit Terminated at 2.5m2.50

    2.002.00

    1.501.50

    1.001.00

    CL CLAY, grey mottled orange, moist, very stiff VStwith some rock fragments

    moist, firm0.50 0.50

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    Moistu

    reCo

    nsiste

    ncy /

    Densi

    tyDy

    namic C

    oneBlo

    ws pe

    r 100

    mmDC

    P estim

    ated

    CBR

    Samp

    ling / R

    unsWa

    ter Le

    velsFIELD TESTS

    & NOTES

    0.00 SM Silty SAND, brown, medium grained D 0.00CH CLAY, red brown mottled grey F

    Lot 30 South St Marsden Park NSW Steve -33.710112NE004-16 YanmarMarsden Park 500mm26/2/2016 AF SD

    TEST PIT LOG PIT No TP10Universal Property Group Art-con Civil 150.829005

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    No groundwaterencountered

    M

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    4.00

    GEOTESTA PTY LTD

    4.00

    T intact tube sample

    3.50 3.50

    3.003.00

    2.50

    Test Pit Terminated at 2.5m2.50

    2.00CL CLAY, grey mottled orange VSt

    with some rock fragments2.00

    1.50

    very stiff

    1.50

    1.001.00grades grey mottled orange, rock fragments in clay matrix VSt

    moist, firm0.50 0.50

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    Moistu

    reCo

    nsiste

    ncy /

    Densi

    tyDy

    namic C

    oneBlo

    ws pe

    r 100

    mmDC

    P estim

    ated

    CBR

    Samp

    ling / R

    unsWa

    ter Le

    velsFIELD TESTS

    & NOTES

    0.00 SM Silty SAND, brown, medium grained D 0.00CH CLAY, red brown mottled grey F

    Lot 30 South St Marsden Park NSW Steve -33.711009NE004-16 YanmarMarsden Park 500mm26/2/2016 AF SD

    TEST PIT LOG PIT No TP11Universal Property Group Art-con Civil 150.828813

  • Page: 1 of 1Client: Excavated by Easting:Project: Operator Northing:Job No: Rig Type: Grid Ref:Location: Pit size Collar RL:Date of test: Logged by: Checked by:

    DM

    No groundwater encountered

    M

    consistency: moisture: notes: B: Bag sample for Acid SulphateVS very soft very loose D Dry J: Jar Sample for Environmental TestsS soft loose M MoistF firm medium dense W WetST stiff denseVST very stiff very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726 Suv Undrained shear Strength - vane shearunless otherwise noted water inflow SPT standard penetration test

    4.00

    GEOTESTA PTY LTD

    4.00

    T intact tube sample

    3.50 3.50

    3.003.00

    2.50

    Test Pit Terminated at 2.5m2.50

    2.00CL CLAY, grey mottled orange VSt

    with some rock fragments2.00

    1.50very stiff

    1.50

    1.00grades grey mottled orange, rock fragments in clay matrix VSt

    1.00

    moist, firm0.50 0.50

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    Moistu

    reCo

    nsiste

    ncy /

    Densi

    tyDy

    namic C

    oneBlo

    ws pe

    r 100

    mmDC

    P estim

    ated

    CBR

    Samp

    ling / R

    unsWa

    ter Le

    velsFIELD TESTS

    & NOTES

    0.00 SM Silty SAND, brown, medium grained D 0.00CH CLAY, red brown mottled grey F

    Lot 30 South St Marsden Park NSW Steve -33.711021NE004-16 YanmarMarsden Park 500mm26/2/2016 AF SD

    TEST PIT LOG PIT No TP12Universal Property Group Art-con Civil 150.828802

  • Page: ofClient: Drilling Co: Easting:Project: Driller: Northing:Job No: Rig Type: Grid Ref:Location: Inclination: Collar RL:Date Drilled: Bearing: Logged by: Checked by:

    consistency: relative density: moisture: notes:VS very soft VL very loose D DryS soft L loose M MoistF firm MD medium dense W WetST stiff D denseVST very stiff VD very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726unless otherwise noted water inflow SPT standard penetration test

    BOREHOLE LOG

    1 2UNIVERSAL PROPERTY GROUP 150.828194

    BORE No BH1

    Lot 30 South St Marsden Park NSW -33.711704NE004-16

    Samp

    ling / R

    unsWa

    ter Le

    velsMATERIAL DESCRIPTION FIELD TESTS

    Type, colour, particle size and shape, structure & NOTES

    Moistu

    re

    Marsden Park26/02/2016 AF SD

    Consi

    stency

    / De

    nsity

    0.00 SM Silty SAND, brown, medium grained D D

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    0.00CH CLAY, red brown mottled grey, moist, firm M F [email protected] 3,4,4 N=8

    grades grey mottled orange1.00 1.00

    grades stiff St [email protected] 3, 6,10 N=16

    2.00 2.00CL CLAY, Extremely Weathered rock, moist, hard M H

    grey mottled orange3.00 [email protected] 9, 23, 40 N>60 3.00

    changed to coring below 3.5mSolid A

    ugering

    T intact tube sample

  • Page: ofClient: Drilling Co: Easting:Project: Driller: Northing:Job No: Rig Type: Grid Ref:Location: Inclination: Collar RL:Date Drilled: Bearing: Logged by: Checked by:

    100

    100

    100

    BOREHOLE LOG BORE No BH1

    2 2UNIVERSAL PROPERTY GROUP 150.828194Lot 30 South St Marsden Park NSW -33.711704NE004-16Marsden Park26/02/2016 AF SD

    Drillin

    g Meth

    odCo

    re rec

    overy %

    RQD %

    Fractu

    re Fre

    q. (no/

    m)Ro

    ck We

    atherin

    g

    Rock

    Streng

    th

    Graphi

    c Log ROCK SUBSTANCE DISCONTINUITIES FIELD TESTS

    Type, colour, texture Type, orientation, roughness, thickness & NOTES3.50

    100 0

    CLAY, grey mottled red brown, moist, hard, low to medium plasticity 3.50EW

    4.50 4.50

    100 0grades green grey mottled orange, with some rock fragments

    5.50 5.50

    HW EL Shale, grey, very low strength, with sub horizontal bedding planes

    6.50 6.5080 MW EL-VL grades extremely to very low strength

    7.50 7.50

    65

    8.50 8.50 VL-L very low to low strength

    9.50 65 9.50SW L-M low to medium strength

    Coring

    END OF BOREHOLE AT 10.0M 10.5010.50

  • Page: ofClient: Drilling Co: Easting:Project: Driller: Northing:Job No: Rig Type: Grid Ref:Location: Inclination: Collar RL:Date Drilled: Bearing: Logged by: Checked by:

    consistency: relative density: moisture: notes:VS very soft VL very loose D DryS soft L loose M MoistF firm MD medium dense W WetST stiff D denseVST very stiff VD very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726unless otherwise noted water inflow SPT standard penetration test

    Marsden Park

    BORE No BH2BOREHOLE LOG1 2

    UNIVERSAL PROPERTY GROUP 150.828574Lot 30 South St Marsden Park NSW -33.709901NE004-16

    Moistu

    re

    26/02/2016 AF SD

    Samp

    ling / R

    unsWa

    ter Le

    velsMATERIAL DESCRIPTION FIELD TESTS

    Type, colour, particle size and shape, structure & NOTES

    0.00 SM Silty SAND, brown, medium grained D D

    Consi

    stency

    / De

    nsity

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    0.00CH CLAY, red brown mottled grey M F

    moist, firm [email protected] 3, 3, 4 N=71.00 1.00

    grades grey mottled orange Ststiff

    2.00 [email protected] 3, 6, 8 N=14 2.00

    grades very stiff

    M H

    Soil augering terminated at 5.0m, changed to rock coring

    4.00CL CLAY, grey mottled red brown

    T intact tube sample

    [email protected] 15, 23, 40 N>60

    VSt [email protected] 6, 8, 11 N=19

    4.00grades hard H

    5.00

    Solid

    augerin

    g

    3.00 3.00

  • Page: ofClient: Drilling Co: Easting:Project: Driller: Northing:Job No: Rig Type: Grid Ref:Location: Inclination: Collar RL:Date Drilled: Bearing: Logged by: Checked by:

    CLAY, grey mottled red brown, moist, hard, low to medium plasticity

    BOREHOLE LOG BORE No BH22 2

    UNIVERSAL PROPERTY GROUP 150.828574Lot 30 South St Marsden Park NSW -33.709901NE004-16Marsden Park26/02/2016 AF SD

    Depth

    (m)

    Drillin

    g Meth

    odCo

    re rec

    overy %

    RQD %

    Fractu

    re Fre

    q. (no/

    m)Ro

    ck We

    atherin

    gRo

    ck Str

    ength

    Graphi

    c Log ROCK SUBSTANCE DISCONTINUITIES FIELD TESTS

    Type, colour, texture Type, orientation, roughness, thickness & NOTES5.00

    6.00

    100 07.00 EL-L Shale, green grey, extremely low to low strength

    100 408.00 MW VL

    100 70

    grades very low strength

    Coring

    100L grades low strength

    709.50

    9.00

    100 0

    Borehole terminated at 9.5m

  • Page: ofClient: Drilling Co: Easting:Project: Driller: Northing:Job No: Rig Type: Grid Ref:Location: Inclination: Collar RL:Date Drilled: Bearing: Logged by: Checked by:

    consistency: relative density: moisture: notes:VS very soft VL very loose D DryS soft L loose M MoistF firm MD medium dense W WetST stiff D denseVST very stiff VD very dense water: sampling / testing:H hard water level intact sample from core disturbed samplesoil classification: level risen to B bulk samplesoil is classified in accordance with AS1726unless otherwise noted water inflow SPT standard penetration test

    BOREHOLE LOG

    1 1UNIVERSAL PROPERTY GROUP 150.827105Lot 30 South St Marsden Park NSW -33.710354NE004-16

    Samp

    ling / R

    unsWa

    ter Le

    velsMATERIAL DESCRIPTION FIELD TESTS

    Type, colour, particle size and shape, structure & NOTES

    Moistu

    re

    Marsden Park26/02/2016 AF SD

    Consi

    stency

    / De

    nsity

    0.00 SM Silty SAND, brown, medium grained D D

    Depth

    (m)

    Drillin

    g Meth

    odGra

    phic L

    og

    Group

    Symb

    ol

    0.00CH CLAY, red brown mottled grey M F

    moist, firmgrades grey mottled orange

    1.00 1.00grades stiff St

    2.00 2.00CL CLAY, grey mottled orange M VSt

    moist, very stiff

    3.00

    4.00 4.00Shale, dark grey, moderately weathered, ELextremely low strength

    5.00

    Solid

    Auger

    ing

    Borehole terminated at 5.6m6.00

    7.00

    3.00

    8.00

    7.00

    5.00

    6.00

    T intact tube sample

    BORE No BH3

    8.00

  • Lot 30, South Street, Marsden Park NE004-16

    19

    APPENDIX B

    LABORATORY TEST RESULTS

  • [email protected] 67.92 51.76 0.064 0.02 0.02 0.2 Samples soaked

    [email protected] 86.45 51.65 0.294 0.11 0.11 1.1 for 24 hours

    Point Load Test ASTM D5741

    NE004-16Project Number: Tested By: ZS

    4/03/2016Client: Universal Property Group P/L Test Date:

    8/03/2016Project Location: Marsden Park, NSW 2765

    Project Name: Lot 30 South Street, Marsden Park Checked By: RK

    Issue Date:

    RemarksBorehole ID Sample ID Test Type

    Specimen

    Length, L

    (mm)

    Specimen

    Diameter, D

    (mm)

    Failure

    Load, P

    (kN)

    Uncorrected Point

    Load Index, Is (MPa)

    Corrected

    Point Load

    Index, Is(50) (MPa)

    Estimated

    Compressive

    Strength

    (MPa)

    DiametralL0365-7

    L0365-8

  • GEOTESTA Pty Ltd

    Unit 6, 31-37 Howleys Road

    Notting Hill , Vic 3168

    Ph: 1300 852216

    Laboratory Geotesta Project Geotechnical Investigation Client Universal Property Group P/L

    Report No L0365-M Project No NE004-16 Client ID -

    Sample ID As below Location Lot 30 South Street Address Unit 1, 129 Magowar Rd

    Borehole ID As below Marsden Park NSW 2765 Girraween, NSW

    Test method:

    Comments

    Test method: AS 1289.2.1.1

    Document: Moisture Content V1 Page 1 of 1

    Accredited for compliance with

    ISO/IEC 17025

    Report issued by: Rene Kurniadi

    Date issued: 11/03/2016

    The results of the tests included in

    this document are traceable to

    Australian and national standards.

    Moisture Content (%)

    L0365-6 [email protected] CLAY 24.4

    L0365-4 [email protected] CLAY 19.8

    L0365-1 [email protected]

    Moisture Content Report

    Sampling Method Tested as received

    L0365-5 [email protected] CLAY 19.6

    L0365-3 [email protected] CLAY 19.5

    AS1289.2.1.1 - Oven Drying Method

    Sample ID Location/Depth Sample Description

    CLAY 19.7

    L0365-2 [email protected] CLAY 21.2

  • GEOTESTA Pty Ltd

    Unit 6, 31-37 Howleys Road

    Notting Hill , Vic 3168

    Ph: 1300 852216

    Laboratory Geotesta Project Geotechnical Investigation Client Universal Property Group P/L

    Report No L0365-G3 Project No NE004-16 Client ID -

    Sample ID L0365-5 Location Lot 30 South Street Address Unit 1, 129 Magowar Rd

    Borehole ID [email protected] Marsden Park NSW 2765 Girraween, NSW

    % %

    Particle Size Distribution

    % Passing Percentage Passing (By Mass)

    ## ## ##Comments

    1. Test is performed with washed grading (washing method)

    Report issued by:

    Date issued: 11/03/2016

    Particle Size Distribution V3

    Rene Kurniadi

    Page 1 of 1

    Accredited for compliance with

    ISO/IEC 17025

    The results of the tests included in

    this document are traceable to

    Australian and national standards.

    Particle Size Distribution

    Test Report

    Sample Description CLAY, trace of sand/gravel, red brown mottled grey, moist

    Sampling Method AS 1289.1.2.1 CL 6.2 - Stockpile

    13.2 mm 100

    26.5 mm

    AS 1289 2.1.1

    Method: AS 1289 3.6.1

    Sieve Limits

    Moisture Content 19.6 Limits Method:

    19.0 mm

    2.36 mm 94

    9.5 mm 100

    6.70 mm 100

    4.75 mm 99

    1.18 mm 92

    600 µm 92

    425 µm 92

    300 µm 91

    75 µm 85

    150 µm 90 26.5

    mm

    19

    .0 m

    m

    13

    .2 m

    m

    9.5

    0 m

    m

    6.7

    0 m

    m

    4.7

    5 m

    m

    2.3

    6 m

    m

    1.1

    8 m

    m

    60

    0 μ

    m

    42

    5 μ

    m

    30

    0 μ

    m

    15

    0 μ

    m

    75

    μm

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

  • GEOTESTA Pty Ltd

    Unit 6, 31-37 Howleys Road

    Notting Hill , Vic 3168

    Ph: 1300 852216

    Laboratory Geotesta Project Geotechnical Investigation Client Universal Property Group P/L

    Report No L0365-G2 Project No NE004-16 Client ID -

    Sample ID L0365-4 Location Lot 30 South Street Address Unit 1, 129 Magowar Rd

    Borehole ID [email protected] Marsden Park NSW 2765 Girraween, NSW

    % %

    Particle Size Distribution

    % Passing Percentage Passing (By Mass)

    ## ## ##Comments

    1. Test is performed with washed grading (washing method)

    150 µm 99

    75 µm 99

    425 µm 99

    300 µm 99

    1.18 mm 100

    600 µm 99

    2.36 mm 100

    9.5 mm 100

    6.70 mm 100

    4.75 mm 100

    AS 1289 2.1.1

    Method: AS 1289 3.6.1

    Sieve Limits

    Moisture Content 19.7 Limits Method:

    19.0 mm

    13.2 mm 100

    26.5 mm

    Particle Size Distribution

    Test Report

    Sample Description CLAY, mottled grey and orange, moist

    Sampling Method Tested as received

    Report issued by:

    Date issued: 11/03/2016

    Particle Size Distribution V3

    Rene Kurniadi

    Page 1 of 1

    Accredited for compliance with

    ISO/IEC 17025

    The results of the tests included in

    this document are traceable to

    Australian and national standards.

    26

    .5 m

    m

    19

    .0 m

    m

    13

    .2 m

    m

    9.5

    0 m

    m

    6.7

    0 m

    m

    4.7

    5 m

    m

    2.3

    6 m

    m

    1.1

    8 m

    m

    60

    0 μ

    m

    42

    5 μ

    m

    30

    0 μ

    m

    15

    0 μ

    m

    75

    μm

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

  • GEOTESTA Pty Ltd

    Unit 6, 31-37 Howleys Road

    Notting Hill , Vic 3168

    Ph: 1300 852216

    Laboratory Geotesta Project Geotechnical Investigation Client Universal Property Group P/L

    Report No L0365-G1 Project No NE004-16 Client ID -

    Sample ID L0365-2 Location Lot 30 South Street Address Unit 1, 129 Magowar Rd

    Borehole ID [email protected] Marsden Park NSW 2765 Girraween, NSW

    % %

    Particle Size Distribution

    % Passing Percentage Passing (By Mass)

    ## ## ##Comments

    1. Test is performed with washed grading (washing method)

    150 µm 100

    75 µm 99

    425 µm 100

    300 µm 100

    1.18 mm 100

    600 µm 100

    2.36 mm 100

    9.5 mm 100

    6.70 mm 100

    4.75 mm 100

    AS 1289 2.1.1

    Method: AS 1289 3.6.1

    Sieve Limits

    Moisture Content 21.8 Limits Method:

    19.0 mm

    13.2 mm 100

    26.5 mm

    Particle Size Distribution

    Test Report

    Sample Description CLAY, mottled grey and orange, moist

    Sampling Method Tested as received

    Report issued by:

    Date issued: 11/03/2016

    Particle Size Distribution V3

    Rene Kurniadi

    Page 1 of 1

    Accredited for compliance with

    ISO/IEC 17025

    The results of the tests included in

    this document are traceable to

    Australian and national standards.

    26

    .5 m

    m

    19

    .0 m

    m

    13

    .2 m

    m

    9.5

    0 m

    m

    6.7

    0 m

    m

    4.7

    5 m

    m

    2.3

    6 m

    m

    1.1

    8 m

    m

    60

    0 μ

    m

    42

    5 μ

    m

    30

    0 μ

    m

    15

    0 μ

    m

    75

    μm

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

  • GEOTESTA Pty Ltd

    Plasticity Index & Linear Shrinkage Unit 6, 31-37 Howleys Road

    Notting Hill , Vic 3168

    Ph: 1300 852216

    Geotesta Project Geotechnical Investigation Client Universal Property Group P/L

    L0365-A3 Project No NE004-16 Client ID -

    L0365-7 Location Lot 30 South Street Address Unit 1, 129 Magowar Rd

    [email protected] Marsden Park NSW 2765 Girraween, NSW

    Results Notes

    % History of sample:

    % Method of preparation:

    % Linear shrinkage:

    % Length of mould:

    Comments

    Test methods: AS 1289, 2.1.1, 3.1.2, 3.2.1, 3.3.1, 3.4.1

    The results of the tests included in

    this document are traceable to

    Australian and national standards.

    Oven-dried

    Dry-sieved

    Curling

    21

    45

    Page 1 of 1

    250 mm

    Plastic limit

    Plasticity index

    Linear shrinkage

    66

    Accredited for compliance with

    ISO/IEC 17025

    Atterberg Limits

    Report issued by:

    Date issued: 11/03/2016

    Tests (LL PL PI LS) V4

    Rene Kurniadi

    16

    Sampling Method

    Liquid limit

    Tested as received

    CLAY, red brown mottled grey, moist

    Test Report

    Sample Description

    Laboratory

    Report No

    Sample ID

    Borehole ID

  • GEOTESTA Pty Ltd

    Plasticity Index & Linear Shrinkage Unit 6, 31-37 Howleys Road

    Notting Hill , Vic 3168

    Ph: 1300 852216

    Geotesta Project Geotechnical Investigation Client Universal Property Group P/L

    L0365-A2 Project No NE004-16 Client ID -

    L0365-4 Location Lot 30 South Street Address Unit 1, 129 Magowar Rd

    [email protected] Marsden Park NSW 2765 Girraween, NSW

    Results Notes

    % History of sample:

    % Method of preparation:

    % Linear shrinkage:

    % Length of mould:

    Comments

    Test methods: AS 1289, 2.1.1, 3.1.2, 3.2.1, 3.3.1, 3.4.1

    Tested as received

    CLAY, mottled grey and orange, moist

    Test Report

    Sample Description

    Laboratory

    Report No

    Sample ID

    Borehole ID

    Atterberg Limits

    Report issued by:

    Date issued: 11/03/2016

    Tests (LL PL PI LS) V4

    Rene Kurniadi

    16

    Sampling Method

    Liquid limitPlastic limit

    Plasticity index

    Linear shrinkage

    83

    Accredited for compliance with

    ISO/IEC 17025

    The results of the tests included in

    this document are traceable to

    Australian and national standards.

    Oven-dried

    Dry-sieved

    No Crack

    24

    59

    Page 1 of 1

    200 mm

  • GEOTESTA Pty Ltd

    Plasticity Index & Linear Shrinkage Unit 6, 31-37 Howleys Road

    Notting Hill , Vic 3168

    Ph: 1300 852216

    Geotesta Project Geotechnical Investigation Client Universal Property Group P/L

    L0365-A1 Project No NE004-16 Client ID -

    L0365-1 Location Lot 30 South Street Address Unit 1, 129 Magowar Rd

    [email protected] Marsden Park NSW 2765 Girraween, NSW

    Results Notes

    % History of sample:

    % Method of preparation:

    % Linear shrinkage:

    % Length of mould:

    Comments

    Test methods: AS 1289, 2.1.1, 3.1.2, 3.2.1, 3.3.1, 3.4.1

    Tested as received

    CLAY, mottled grey and orange, moist

    Test Report

    Sample Description

    Laboratory

    Report No

    Sample ID

    Borehole ID

    Atterberg Limits

    Report issued by:

    Date issued: 11/03/2016

    Tests (LL PL PI LS) V4

    Rene Kurniadi

    13

    Sampling Method

    Liquid limitPlastic limit

    Plasticity index

    Linear shrinkage

    54

    Accredited for compliance with

    ISO/IEC 17025

    The results of the tests included in

    this document are traceable to

    Australian and national standards.

    Oven-dried

    Dry-sieved

    No Crack

    18

    36

    Page 1 of 1

    250 mm

  • 0 0.00 True

    Environmental

    CERTIFICATE OF ANALYSISWork Order : Page : 1 of 4ES1605727

    :: LaboratoryClient GEOTESTA Environmental Division Sydney

    : :ContactContact AMIR FARAZMAND

    :: AddressAddress UNIT 6, 31-37 HOWLEYS ROAD

    NOTTING HILL 3168

    277-289 Woodpark Road Smithfield NSW Australia 2164

    :Telephone +61 03 9562 8808 :Telephone +61-2-8784 8555

    NATA Accredited Laboratory 825

    Accredited for compliance with

    ISO/IEC 17025.

    :Project South St Marsden Park Date Samples Received : 15-Mar-2016 09:40

    :Order number ---- Date Analysis Commenced : 16-Mar-2016

    :C-O-C number ---- Issue Date : 30-Mar-2016 09:30

    Sampler : AMIR FARAZMAND

    Site : ----

    Quote number : ----

    7:No. of samples received

    7:No. of samples analysed

    This report supersedes any previous report(s) with this reference. Results apply to the sample(s) as submitted.

    This Certificate of Analysis contains the following information:

    l General Comments

    l Analytical Results

    Additional information pertinent to this report will be found in the following separate attachments: Quality Control Report, QA/QC Compliance Assessment to assist with

    Quality Review and Sample Receipt Notification.

    SignatoriesThis document has been electronically signed by the authorized signatories below. Electronic signing is carried out in compliance with procedures specified in 21 CFR Part 11.

    Signatories Accreditation CategoryPosition

    Ashesh Patel Inorganic Chemist Sydney Inorganics, Smithfield, NSW

    Celine Conceicao Senior Spectroscopist Sydney Inorganics, Smithfield, NSW

    Edwandy Fadjar Organic Coordinator Sydney Inorganics, Smithfield, NSW

    R I G H T S O L U T I O N S | R I G H T P A R T N E R

  • 2 of 4:Page

    Work Order :

    :Client

    ES1605727

    South St Marsden Park:Project

    GEOTESTA

    General Comments

    The analytical procedures used by the Environmental Division have been developed from established internationally recognized procedures such as those published by the USEPA, APHA, AS and NEPM. In house

    developed procedures are employed in the absence of documented standards or by client request.

    Where moisture determination has been performed, results are reported on a dry weight basis.

    Where a reported less than (

  • 3 of 4:Page

    Work Order :

    :Client

    ES1605727

    South St Marsden Park:Project

    GEOTESTA

    Analytical Results

    TP3 1.5MTP6 2.5MTP8 1.0MTP10 1.0MTP12 1.7MClient sample IDSub-Matrix: SOIL (Matrix: SOIL)

    [26-Feb-2016][26-Feb-2016][26-Feb-2016][26-Feb-2016][26-Feb-2016]Client sampling date / time

    ES1605727-005ES1605727-004ES1605727-003ES1605727-002ES1605727-001UnitLORCAS NumberCompound

    Result Result Result Result Result

    EA002 : pH (Soils)

    4.8 4.8 5.0 4.8 4.9pH Unit0.1----pH Value

    EA055: Moisture Content

    14.0 22.9 17.0 17.4 15.3%1----Moisture Content (dried @ 103°C)

    ED040S : Soluble Sulfate by ICPAES

    350Sulfate as SO4 2- 240 240 380 530mg/kg1014808-79-8

  • 4 of 4:Page

    Work Order :

    :Client

    ES1605727

    South St Marsden Park:Project

    GEOTESTA

    Analytical Results

    ------------BH2 0.5MBH3 4.0MClient sample IDSub-Matrix: SOIL (Matrix: SOIL)

    ------------[26-Feb-2016][26-Feb-2016]Client sampling date / time

    ------------------------ES1605727-007ES1605727-006UnitLORCAS NumberCompound

    Result Result Result Result Result

    EA002 : pH (Soils)

    6.9 4.9 ---- ---- ----pH Unit0.1----pH Value

    EA055: Moisture Content

    8.7 16.2 ---- ---- ----%1----Moisture Content (dried @ 103°C)

    ED040S : Soluble Sulfate by ICPAES

    260Sulfate as SO4 2- 290 ---- ---- ----mg/kg1014808-79-8

  • True

    Environmental

    QA/QC Compliance Assessment to assist with Quality ReviewWork Order : ES1605727 Page : 1 of 5

    :: LaboratoryClient Environmental Division SydneyGEOTESTA

    :Contact AMIR FARAZMAND Telephone : +61-2-8784 8555

    :Project South St Marsden Park Date Samples Received : 15-Mar-2016

    Site : ---- Issue Date : 30-Mar-2016

    AMIR FARAZMAND:Sampler No. of samples received : 7

    :Order number ---- No. of samples analysed : 7

    This report is automatically generated by the ALS LIMS through interpretation of the ALS Quality Control Report and several Quality Assurance parameters measured by ALS. This automated

    reporting highlights any non-conformances, facilitates faster and more accurate data validation and is designed to assist internal expert and external Auditor review. Many components of this

    report contribute to the overall DQO assessment and reporting for guideline compliance.

    Brief method summaries and references are also provided to assist in traceability.

    Summary of Outliers

    Outliers : Quality Control Samples

    This report highlights outliers flagged in the Quality Control (QC) Report.

    l NO Method Blank value outliers occur.

    l NO Duplicate outliers occur.

    l NO Laboratory Control outliers occur.

    l NO Matrix Spike outliers occur.

    l For all regular sample matrices, NO surrogate recovery outliers occur.

    Outliers : Analysis Holding Time Compliance

    l Analysis Holding Time Outliers exist - please see following pages for full details.

    Outliers : Frequency of Quality Control Samples

    l Quality Control Sample Frequency Outliers exist - please see following pages for full details.

    R I G H T S O L U T I O N S | R I G H T P A R T N E R

  • 2 of 5:Page

    Work Order :

    :Client

    ES1605727

    GEOTESTA

    South St Marsden Park:Project

    Outliers : Analysis Holding Time Compliance

    Matrix: SOIL

    AnalysisExtraction / Preparation

    Date analysedDate extractedContainer / Client Sample ID(s) Days

    overdue

    Days

    overdue

    Due for extraction Due for analysis

    Method

    EA002 : pH (Soils)

    Snap Lock Bag

    ----04-Mar-2016TP12 1.7M, TP10 1.0M,

    TP8 1.0M, TP6 2.5M,

    TP3 1.5M, BH3 4.0M,

    BH2 0.5M

    ----18-Mar-2016 14 ----

    EA055: Moisture Content

    Snap Lock Bag

    11-Mar-2016----TP6 2.5M 16-Mar-2016---- ---- 5

    Snap Lock Bag

    11-Mar-2016----TP12 1.7M, TP10 1.0M,

    TP8 1.0M, TP3 1.5M,

    BH3 4.0M, BH2 0.5M

    17-Mar-2016---- ---- 6

    Outliers : Frequency of Quality Control Samples

    Matrix: SOIL

    Quality Control SpecificationQuality Control Sample Type

    Method ExpectedQC Regular Actual

    Rate (%)Quality Control Sample Type Count

    Laboratory Duplicates (DUP)

    NEPM 2013 B3 & ALS QC StandardMoisture Content 9.76 10.004 41

    Analysis Holding Time Compliance

    Holding times for VOC in soils vary according to analytes of interest. Vinyl Chloride and Styrene holding time is 7 days; others 14 days. A recorded breach does not guarantee a breach for all VOC analytes and

    should be verified in case the reported breach is a false positive or Vinyl Chloride and Styrene are not key analytes of interest/concern.

    Holding time for leachate methods (e.g. TCLP) vary according to the analytes reported. Assessment compares the leach date with the shortest analyte holding time for the equivalent soil method. These are: organics

    14 days, mercury 28 days & other metals 180 days. A recorded breach does not guarantee a breach for all non-volatile parameters.

    If samples are identified below as having been analysed or extracted outside of recommended holding times, this should be taken into consideration when interpreting results.

    This report summarizes extraction / preparation and analysis times and compares each with ALS recommended holding times (referencing USEPA SW 846, APHA, AS and NEPM) based on the sample container

    provided. Dates reported represent first date of extraction or analysis and preclude subsequent dilutions and reruns. A listing of breaches (if any) is provided herein.

    Matrix: SOIL Evaluation: û = Holding time breach ; ü = Within holding time.

    AnalysisExtraction / PreparationSample DateMethod

    EvaluationDue for analysisDate analysedEvaluationDue for extractionDate extractedContainer / Client Sample ID(s)

    EA002 : pH (Soils)

    Snap Lock Bag (EA002)

    TP12 1.7M, TP10 1.0M,

    TP8 1.0M, TP6 2.5M,

    TP3 1.5M, BH3 4.0M,

    BH2 0.5M

    18-Mar-201604-Mar-2016 18-Mar-201618-Mar-201626-Feb-2016 û ü

  • 3 of 5:Page

    Work Order :

    :Client

    ES1605727

    GEOTESTA

    South St Marsden Park:Project

    Matrix: SOIL Evaluation: û = Holding time breach ; ü = Within holding time.

    AnalysisExtraction / PreparationSample DateMethod

    EvaluationDue for analysisDate analysedEvaluationDue for extractionDate extractedContainer / Client Sample ID(s)

    EA055: Moisture Content

    Snap Lock Bag (EA055-103)

    TP6 2.5M 11-Mar-2016---- 16-Mar-2016----26-Feb-2016 ---- ûSnap Lock Bag (EA055-103)

    TP12 1.7M, TP10 1.0M,

    TP8 1.0M, TP3 1.5M,

    BH3 4.0M, BH2 0.5M

    11-Mar-2016---- 17-Mar-2016----26-Feb-2016 ---- û

    ED040S : Soluble Sulfate by ICPAES

    Snap Lock Bag (ED040S)

    TP12 1.7M, TP10 1.0M,

    TP8 1.0M, TP6 2.5M,

    TP3 1.5M, BH3 4.0M,

    BH2 0.5M

    15-Apr-201625-Mar-2016 18-Mar-201618-Mar-201626-Feb-2016 ü ü

  • 4 of 5:Page

    Work Order :

    :Client

    ES1605727

    GEOTESTA

    South St Marsden Park:Project

    Quality Control Parameter Frequency ComplianceThe following report summarises the frequency of laboratory QC samples analysed within the analytical lot(s) in which the submitted sample(s) was(were) processed. Actual rate should be greater than or equal to

    the expected rate. A listing of breaches is provided in the Summary of Outliers.

    Matrix: SOIL Evaluation: û = Quality Control frequency not within specification ; ü = Quality Control frequency within specification.

    Quality Control SpecificationQuality Control Sample Type

    ExpectedQC Regular Actual

    Rate (%)Quality Control Sample Type CountEvaluationAnalytical Methods Method

    Laboratory Duplicates (DUP)

    NEPM 2013 B3 & ALS QC Standard 14.29 10.001 7 üMajor Anions - Soluble ED040SNEPM 2013 B3 & ALS QC Standard 9.76 10.004 41 ûMoisture Content EA055-103NEPM 2013 B3 & ALS QC Standard 14.29 10.002 14 üpH (1:5) EA002

    Laboratory Control Samples (LCS)

    NEPM 2013 B3 & ALS QC Standard 14.29 5.001 7 üMajor Anions - Soluble ED040SMethod Blanks (MB)

    NEPM 2013 B3 & ALS QC Standard 14.29 5.001 7 üMajor Anions - Soluble ED040S

  • 5 of 5:Page

    Work Order :

    :Client

    ES1605727

    GEOTESTA

    South St Marsden Park:Project

    Brief Method SummariesThe analytical procedures used by the Environmental Division have been developed from established internationally recognized procedures such as those published by the US EPA, APHA, AS and NEPM. In house

    developed procedures are employed in the absence of documented standards or by client request. The following report provides brief descriptions of the analytical procedures employed for results reported in the

    Certificate of Analysis. Sources from which ALS methods have been developed are provided within the Method Descriptions.

    Analytical Methods Method DescriptionsMatrixMethod

    In house: Referenced to APHA 4500H+. pH is determined on soil samples after a 1:5 soil/water leach. This

    method is compliant with NEPM (2013) Schedule B(3) (Method 103)

    pH (1:5) EA002 SOIL

    In house: A gravimetric procedure based on weight loss over a 12 hour drying period at 103-105 degrees C.

    This method is compliant with NEPM (2013) Schedule B(3) Section 7.1 and Table 1 (14 day holding time).

    Moisture Content EA055-103 SOIL

    In house: Soluble Anions are determined off a 1:5 soil / water extract by ICPAES.Major Anions - Soluble ED040S SOIL

    Preparation Methods Method DescriptionsMatrixMethod

    10 g of soil is mixed with 50 mL of distilled water and tumbled end over end for 1 hour. Water soluble salts are

    leached from the soil by the continuous suspension. Samples are settled and the water filtered off for analysis.

    1:5 solid / water leach for soluble

    analytes

    EN34 SOIL

    In house: Referenced to USEPA 200.2. Hot Block Acid Digestion 1.0g of sample is heated with Nitric and

    Hydrochloric acids, then cooled. Peroxide is added and samples heated and cooled again before being filtered

    and bulked to volume for analysis. Digest is appropriate for determination of selected metals in sludge,

    sediments, and soils. This method is compliant with NEPM (2013) Schedule B(3) (Method 202)

    Hot Block Digest for metals in soils

    sediments and sludges

    EN69 SOIL

    In house: Referenced to USEPA SW 846 - 5030A. 5g of solid is shaken with surrogate and 10mL methanol prior

    to analysis by Purge and Trap - GC/MS.

    Methanolic Extraction of Soils for Purge

    and Trap

    * ORG16 SOIL

    In house: Mechanical agitation (tumbler). 10g of sample, Na2SO4 and surrogate are extracted with 30mL 1:1

    DCM/Acetone by end over end tumble. The solvent is decanted, dehydrated and concentrated (by KD) to the

    desired volume for analysis.

    Tumbler Extraction of Solids ORG17 SOIL

  • False 3 3.00True

    Environmental

    QUALITY CONTROL REPORTWork Order : ES1605727 Page : 1 of 3

    :: LaboratoryClient Environmental Division SydneyGEOTESTA

    :Contact AMIR FARAZMAND :Contact

    :Address UNIT 6, 31-37 HOWLEYS ROAD

    NOTTING HILL 3168

    Address : 277-289 Woodpark Road Smithfield NSW Australia 2164

    ::Telephone +61 03 9562 8808 +61-2-8784 8555:Telephone

    NATA Accredited Laboratory 825

    Accredited for compliance with

    ISO/IEC 17025.

    :Project South St Marsden Park Date Samples Received : 15-Mar-2016

    :Order number ---- Date Analysis Commenced : 16-Mar-2016

    :C-O-C number ---- Issue Date : 30-Mar-2016

    Sampler : AMIR FARAZMAND

    Site : ----

    Quote number : ----

    No. of samples received 7:

    No. of samples analysed 7:

    This report supersedes any previous report(s) with this reference. Results apply to the sample(s) as submitted.

    This Quality Control Report contains the following information:

    l Laboratory Duplicate (DUP) Report; Relative Percentage Difference (RPD) and Acceptance Limits

    l Method Blank (MB) and Laboratory Control Spike (LCS) Report ; Recovery and Acceptance Limits

    l Matrix Spike (MS) Report; Recovery and Acceptance Limits

    SignatoriesThis document has been electronically signed by the authorized signatories below. Electronic signing is carried out in compliance with procedures specified in 21 CFR Part 11.

    Signatories Accreditation CategoryPosition

    Ashesh Patel Inorganic Chemist Sydney Inorganics, Smithfield, NSW

    Celine Conceicao Senior Spectroscopist Sydney Inorganics, Smithfield, NSW

    Edwandy Fadjar Organic Coordinator Sydney Inorganics, Smithfield, NSW

    R I G H T S O L U T I O N S | R I G H T P A R T N E R

  • 2 of 3:Page

    Work Order :

    :Client

    ES1605727

    GEOTESTA

    South St Marsden Park:Project

    General Comments

    The analytical procedures used by the Environmental Division have been developed from established internationally recognized procedures such as those published by the USEPA, APHA, AS and NEPM. In house

    developed procedures are employed in the absence of documented standards or by client request.

    Where moisture determination has been performed, results are reported on a dry weight basis.

    Where a reported less than ( 20 times LOR: 0% - 20%.

    Sub-Matrix: SOIL Laboratory Duplicate (DUP) Report

    Original Result RPD (%)Laboratory sample ID Client sample ID Method: Compound CAS Number LOR Unit Duplicate Result Recovery Limits (%)

    EA002 : pH (Soils) (QC Lot: 399022)

    EA002: pH Value ---- 0.1 pH Unit 4.8 4.7 2.12 0% - 20%TP12 1.7M ES1605727-001

    EA002: pH Value ---- 0.1 pH Unit 9.6 9.6 0.00 0% - 20%Anonymous ES1605783-001

    EA055: Moisture Content (QC Lot: 396057)

    EA055-103: Moisture Content (dried @ 103°C) ---- 1 % 10.5 9.4 10.4 0% - 50%Anonymous ES1605770-002

    EA055-103: Moisture Content (dried @ 103°C) ---- 1 % 5.7 6.2 9.45 No LimitAnonymous ES1605770-013

    EA055: Moisture Content (QC Lot: 397737)

    EA055-103: Moisture Content (dried @ 103°C) ---- 1 % 17.5 17.9 2.25 0% - 50%Anonymous ES1605682-003

    EA055-103: Moisture Content (dried @ 103°C) ---- 1 % 6.3 7.2 13.9 No LimitAnonymous ES1605767-002

    ED040S: Soluble Major Anions (QC Lot: 399021)

    ED040S: Sulfate as SO4 2- 14808-79-8 10 mg/kg 350 300 14.9 0% - 20%TP12 1.7M ES1605727-001

  • 3 of 3:Page

    Work Order :

    :Client

    ES1605727

    GEOTESTA

    South St Marsden Park:Project

    Method Blank (MB) and Laboratory Control Spike (LCS) Report

    The quality control term Method / Laboratory Blank refers to an analyte free matrix to which all reagents are added in the same volumes or proportions as used in standard sample preparation. The purpose of this QC

    parameter is to monitor potential laboratory contamination. The quality control term Laboratory Control Spike (LCS) refers to a certified reference material, or a known interference free matrix spiked with target

    analytes. The purpose of this QC parameter is to monitor method precision and accuracy independent of sample matrix. Dynamic Recovery Limits are based on statistical evaluation of processed LCS.

    Sub-Matrix: SOIL Method Blank (MB) Report

    Laboratory Control Spike (LCS) Report

    Spike Spike Recovery (%) Recovery Limits (%)

    Result Concentration HighLowLCSMethod: Compound CAS Number LOR Unit

    ED040S: Soluble Major Anions (QCLot: 399021)

    ED040S: Sulfate as SO4 2- 14808-79-8 10 mg/kg

  • Lot 30, South Street, Marsden Park NE004-16

    20

    APPENDIX C

    CORE AND TEST PIT PHOTOS

  • Lot 30, South Street, Marsden Park NE004-16

    21

    Borehole 1 - 3.5m-10.0m

    Borehole 2 – 4.9m-9.5m

  • Lot 30, South Street, Marsden Park NE004-16

    22

    Test pit 1

  • Lot 30, South Street, Marsden Park NE004-16

    23

    Test pit 2

  • Lot 30, South Street, Marsden Park NE004-16

    24

    Test pit 3

  • Lot 30, South Street, Marsden Park NE004-16

    25

    Test pit 4

  • Lot 30, South Street, Marsden Park NE004-16

    26

    Test pit 5

  • Lot 30, South Street, Marsden Park NE004-16

    27

    Test pit 6

  • Lot 30, South Street, Marsden Park NE004-16

    28

    Test pit 7

  • Lot 30, South Street, Marsden Park NE004-16

    29

    Test pit 8

  • Lot 30, South Street, Marsden Park NE004-16

    30

    Test pit 9

  • Lot 30, South Street, Marsden Park NE004-16

    31

    Test pit 10

  • Lot 30, South Street, Marsden Park NE004-16

    32

    Test pit 11

  • Lot 30, South Street, Marsden Park NE004-16

    33

    Test pit 12