gidm indirect-fired heating and ventilating unitsice-us.com/site/1853ice_/gidm_new_catalogue.pdf ·...
TRANSCRIPT
EXCELLENCE THROUGH PROVEN PERFORMANCE
GIDM Indirect-Fired Heatingand Ventilating Units
INDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD.
®
US
GIDM0406BR
INDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD.
Originally founded as Bullocks Manufacturing during the post-war residential
housing boom, I.C.E. Manufacturing was recognized for innovation and
excellence early in our history. After the company established a reputation for
designing, manufacturing and installing natural gas conversion burners for oil
and coal-fired furnaces, founder Don Bullocks returned from an ASHRAE trade
show with a natural gas line burner. Inspired, he set out to manufacture the first
direct-fired makeup air unit in his home country of Canada.
Today, the natural gas revolution continues with I.C.E. Manufacturing at the
forefront of the commercial direct-fired industry. Don had the vision long before
many others by designing a product that has outlived his legend. Our BMA
Series is named for him (Bullocks Makeup Air). This forward thinking has carried
on through such advanced products as the HTDM, the gas valve technology
available on the BMA, and the industrial-quality GIDM product line.
All of our products have withstood the test of time. Many new products are on
the horizon to meet the ever-increasing concern over energy costs, consumption
and impact on our environment. We are building on our heritage to bring
exceptional gas-fired products to market.
I.C.E. is committed to success – the success of our customers and our
employees. To us, success is driven by loyalty that comes from service, quality
and innovation. With our vast experience in the HVAC industry, we continue to
listen to and understand the needs of our customers. And we trust we will be
able to serve you well into the future.
EXCELLENCE THROUGH PROVEN PERFORMANCE
Table of Contents
APPLICATION GUIDE FOR INDIRECT FIRED GIDM/GIDMH SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
STANDARD FEATURES / OPTIONAL FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
GIDM SERIES TEMPERATURE CONTROL PACKAGES / MISCELLANEOUS CONTROL OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
AMPERAGE SPECIFICATIONS / STATIC PRESSURE DUE TO ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
FILTER SECTION SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
WEIGHT SPECIFICATIONS (POUNDS). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
GIDM PERFORMANCE SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W ANGULAR FILTER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W V-BANK FILTER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W V-BANK FILTER SECTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W ANGULAR FILTER SECTION AND MIX BOX . . . . . . . . . . . . . . . . . . . . . . 17
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX . . . . . . . . . . . . . . . . . . . . . . . . . . 18
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX . . . . . . . . . . . . . . . . . . . . . . . . . 19
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W V-BANK FILTER SECTION AND MIX BOX. . . . . . . . . . . . . . . . . . . . . . . . 20
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W V-BANK FILTER SECTION AND MIX BOX . . . . . . . . . . . . . . . . . . . . . . 21
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND DX COIL. . . . . . . . . . . . . . . . . . . . . . . . . . . 22
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND DX COIL . . . . . . . . . . . . . . . . . . . . . . . . . 23
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION, MIX BOX AND DX COIL . . . . . . . . . . . . . . . . . . 24
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION, MIX BOX AND DX COIL . . . . . . . . . . . . . . . . . 25
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX WITH RELIEF . . . . . . . . . . . . . . . 26
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX WITH RELIEF . . . . . . . . . . . . . 27
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX WITH RELIEF
AND RETURN AIR BLOWER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION, MIX BOX WITH RELIEF
AND RETURN AIR BLOWER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH FLAT FILTER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . 30
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH ANGULAR FILTER SECTION. . . . . . . . . . . . . . . . . . . . . 31
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH V-BANK FILTER SECTION. . . . . . . . . . . . . . . . . . . . . . . 32
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH FLAT FILTER SECTION AND MIX BOX . . . . . . . . . . . . . 33
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH ANGULAR FILTER SECTION AND MIX BOX . . . . . . . . 34
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH V-BANK FILTER SECTION AND MIX BOX . . . . . . . . . . 35
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH FLAT FILTER SECTION AND DX COIL . . . . . . . . . . . . . 36
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH FLAT FILTER SECTION, DX COIL AND MIX BOX . . . . . 37
GIDM SERIES HORIZONTAL CONFIG. OUTDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX WITH RELIEF
AND RETURN AIR BLOWER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
GIDMH SERIES HORIZONTAL CONFIG. OUTDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION, MIX BOX WITH RELIEF
AND RETURN AIR BLOWER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
GIDM/GIDMH MODULATING MANIFOLD ARRANGEMENT FOR CGA, ETL, F.M., AND I.R.I. APPROVAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Application Guide For Indirect Fired GIDM/GIDMH Series
• GIDM unit models are designated by their MBH output. Thus a GIDM 75 has 750 MBH output, or 750,000 BTUH.
• All GIDM units are 80% efficient at high fire, thus, output is BTUH input * 0.80
• Once you have chosen your required BTUH output, you can use BTUH output/0.80 to find your required input, or actual gas consumption. Using the desired output you can select your model.
• Choose your airflow (this may be your first step if the unit is applied in a make-up air situation)
• Calculate your TSP (add your ESP with your accessories – accessory pressure drops can be found on page 6). With your airflow and TSP selectedyou can find your BHP from the charts on pages 10-12
• Unit weights can be found on page 8 & 9
• Given the entering and leaving air dry bulb temperatures or temperature rise, the equation below can be used to calculate the required MBH capacity
MBH Capacity = (CFM x C x (LAT-EAT))/0.80/1000
MBH capacity: BTUH/1000 (British Thermal units per hour)
CFM: Cubic Feet per minute of air
C: Gas constant of 1.08 based on air density at 75 deg. F
EAT: Entering air dry bulb temperature (deg. F)
LAT: Leaving air dry bulb temperature (deg. F)
0.8: GIDM Series Efficiency
Example For Make-Up Air
A manufacturing facility needs pressurization via make-up air. 10% pressurization is deemed to be appropriate and it is determined that 25,720 CFMexhaust is required. -20 deg. F is the design ambient, and desired discharge temp is 70 deg. F. Units will be roof mounted, down discharge, and willhave an ESP of 0.60" W.C. Select the appropriate GIDM model, and find the BHP for the unit.
Selection:
• Since we are exhausting 25,720 CFM, and desire 10% pressurization, we can calculate that we need 28,300 CFM of supply air (25,720 + 10% = 28300)
• We know our EAT = -20 deg. F, and LAT = 70 deg. F, thus we can calculate:
• MBH Output Capacity = (CFM x C x (LAT-EAT))/1000
• MBH Output Capacity = (28,300 x 1.08 x (70 - (-20)))/1000
• MBH Output Capacity = 2,750.00
• The closest model available is the GIDM 275 which has 2,750 MBH output, and 3,437.5 MBH input
We can now calculate our TSP:
• We are selecting the basic options – inlet filters and damper
• Inlet damper = 0.1" W.C (Page 6)
• Inlet Filters = 0.3" W.C (Page 6)
• TSP = ESP + Accessories
• TSP = 0.60 + 0.1 + 0.3
• TSP = 1.0" W.C.
• Consulting the chart for the GIDM 275 (page 12) at 28,300 CFM and 1.0" W.C we find our BHP = 16.28 BHP – Thus we need a 20.0 HP motor minimum.
Example for Heat-Vent Unit
A small warehouse needs a minimum of 20% fresh air in unoccupied (night time) mode and 100% fresh air in occupied mode (during the day with forkliftin the building). It has been calculated that at -30 deg. F the room loses 1,000,000 BTUH. It has been determined that 11,000 CFM is required for theapplication. The outdoor air is -30 deg. F, and desired leaving air is 75 deg. F. Return air will be 70 deg. F. ESP is calculated to be 0.5" W.C. Select theappropriate model and find the BHP for the unit.
Selection:
Part 1 (Unoccupied mode)
• We only bring in 20% outside air in this mode, thus 2200 CFM is outside air and 8800 CFM is return air
• We know our EAT for outside air = -30 deg. F, and LAT = 75 deg. F, thus we can calculate:
• MBH Capacity = (CFM x C x (LAT-EAT))/1000
• MBH Capacity = (2,200 x 1.08 x (75 - (-30)))/1000
• MBH Capacity = 249.48
• We also know that the room is losing 1,000 MBH, thus we need to add that to the calculation. Thus the total Heat input capacity required = 1,250 MBH
• Before we select our model we must check the occupied mode to ensure we have sufficient heat capacity.
2
Part 2 (Occupied mode)
• We will be delivering 11,000 CFM of outside in this mode
• We know our EAT for outside air = -30 deg. F, and LAT = 75 deg. F, thus we can calculate:
• MBH Capacity = (CFM x C x (LAT-EAT))/0.80/1000
• MBH Capacity = (11,000 x 1.08 x (75 - (-30)))/0.80/1000
• MBH Capacity = 1,247.40
• Thus to satisfy both options we need to use a GIDM 125.
Note: In this example we are assuming there is an alternate source of heat that will be used during occupied mode to make-up for the heat loss of thewarehouse, which will not be used in un-occupied mode.
We can now calculate our TSP:
• We are selecting the basic options – inlet filters and damper
• Inlet damper = 0.1" W.C (Page 6)
• Inlet Filters = 0.3" W.C (Page 6)
• TSP = ESP + Accessories
• TSP = 0.50 + 0.1 + 0.3
• TSP = 0.9" W.C. (Round up to 1.0" W.C)
• Consulting the chart for the GIDM 125 (page 10) at 11,000 CFM (Use 11,574 CFM) and 1.0" W.C we find our BHP = 5.75 BHP – We can use a 7.5 hp motor.
Example for a Heating Only Unit
A door heater for a large overhead door can potentially see 100% fresh air during times when the overhead doors open frequently. Thus a durable GIDMunit should be selected for this application. 18,000 CFM at 0.5" W.C is determined to be the appropriate amount of air for the vestibule, and 1250 MBHis calculated to be the appropriate amount of heat capacity required. Select the appropriate model and find the BHP for the unit.
Selection:
• Since the heating load calculation has already been completed we simply need to use the heating capacity and match it up with the appropriateGIDM model
• A GIDM 125 is the appropriate model for 1250 MBH
We can now calculate our TSP:
• We are selecting the basic options – inlet filters and damper
• Inlet damper = 0.1" W.C (Page 6)
• Inlet Filters 0.3" W.C (Page 6)
• TSP = ESP + Accessories
• TSP = 0.50 + 0.1 + 0.3
• TSP = 0.9" W.C. (Round up to 1.0" W.C)
• Consulting the chart for the GIDM 125 (page 10) at 18,000 CFM (this value falls between 16,534 CFM and 19,290 CFM) and 1.0" W.C we find ourBHP is between 9.59 BHP and 13.12 BHP. A 15 HP motor should be used.
3
Application Guide For Indirect Fired GIDM/GIDMH Series
Standard Features
4
Mix BoxAllows the recirculation of air to occur. This willprovide a cost effective way of space heating.
Weatherhousing Control and manifold enclosureComes with hinged access completely sealed withTrimseal gasketing and ventlock handles
Inlet HoodsExpanded metal screen inlet.
Filter SectionFlat, Angular or V-bank filter section with sideaccess suitable for 2" filters. Hinged access doors completely sealed with Trimseal gasketing for all models.
Winter Filter SectionLocated on the discharge side of heating section.
Filters2" thick permanent, pleated and throwaway filters;various efficiency bag filters and HEPA filterscomplete with filter gauge and/or indicating light.
Motorized Inlet & Discharge DamperParallel blade damper with a two-position springreturn actuator and end switch.
Roof CurbPrefabricated galvanized roof curb 16" or 24" high;full perimeter available on most units.
BlowersBackward inclined, air foil, and plug fans
DX PlenumCoil located in vertical or horizontal airflowcomplete with drain pan when applicable.
Coil PlenumsHeating coils – steam, hot water, and glycol Cooling coils – chilled water, DX coil
Evaporative CoolersIndustrial and commercial
Hinged Access DoorsStandard on filter section, motor section andweatherhousing. Comes with #140 ventlockhandles, #310 ventlock handles on GIDM 125 and up
Mushroom HoodComplete with internal screen for debris
Louvered InletFlush mountedGalvanized steel blades complete with an internalscreen for debris
4-Way Discharge HeadThe adjustable 4 way discharge head provides 4 equal quantities of air in the conditioned space
Horizontal Discharge Head180 deg. vertical and horizontal adjustment with360 deg. of free rotation
Internal Vibration IsolationBlower and motor isolated on separate frame withR.I.S. or spring c/w canvas connector
External Vibration IsolationFloor mounted or suspended isolation
Service PlatformProvides access to controls and gas train
MotorsTEFC and high-efficiency, meeting EEE and CSAstandards and 2-speed
Disconnect SwitchWeatherproof enclosure; non-fused or fused
FM Gas TrainMeets Factory Mutual (FM) requirements
IRI Gas TrainMeets Industrial Risk Insurers requirements
High Gas Pressure RegulatorRequired on natural gas with pressure in excess of5 psig and LP applications in excess of 11" W.C.
High/Low Gas Pressure SwitchesManual reset, gas pressure safety switches whichlock out the burner in the event of gas pressuremalfunction.
Control PanelsNEMA4 or 12 custom, unit mounted or remoteenclosuresExplosion proof panels
Standard Features
Optional Features
Assurance
• ETL listed, CGA listed
• Factory wired, piped, and test fired
Cabinet
• Welded structural or formed channel base frame primed with rust inhibitor
• Lifting lugs
• Heavy gauge colorbond steel casing with rust-resistant grey enamel paint finish
• One inch thick 1.5# density neoprene coated fiberglass
• The insulation is glued and pinned, solid liner in the burner section
• Two inch insulation is recommended on GIDM 125 & larger
• Unit comes with standard 2" breaks on GIDM 125 & larger
• Sloped roof standard on GIDM 125 and up
Blower/Motor
• AMCA rated forward curve DWDI centrifugal blower
• Polished steel shaft with rust inhibitor
• Maximum operating speed less than 75% of first critical speed
• Standard heavy-duty industrial bearings used on unit with blower sizes20x20 and larger
• Sealed cartridge bearings provided on units with blower sizes 18x18 and smaller.
• ODP motor, 1800 RPM, T frame, 1.15 service factor mounted onadjustable base
• Drives designed for 150% motor brake horsepower
• Adjustable V-belt drives used up to and including 5 HP; fixed drives on 7.5 HP and larger
Burner/Manifold
• Gas, propane or oil power burner
• Factory pre-piped, wired and flame tested
• CGA/ANSI approved 7-14" W.C. gas train
• CGA approved turndown of 7% of output, approximately 15:1 turndown
• Inlet pressure for propane 11" W.C.
Heat Exchanger Section
• Four pass continuously welded 400 series primary with mild steelsecondary heat exchanger
• Five year heat exchanger warranty
• Fully lined and insulated radiation shield
• Direct drive radial blade induced draft blower
• Puff door w/inspection sight glass
Controls Enclosure
• Electronic flame safeguard relay manual reset
• Manual reset high limit
• Factory wired control panel with numbered terminal strip
• Motor starter with overloads
• Control circuit transformer, 120 volt
• Control panel service switch
• Circuit breaker
• Terminal connections for exhaust interlock
• Nationally recognized components, service, and parts
Additional Options
• Auto low limit freeze protectioncontrol with bypass timer
• 10 point electronic circuit analyzer with signal lights
• Exhaust Interlock Relay
• Proof of Closure Valve
• Inlet Air Controller (burner economizer)
• Ultra violet flame supervision
• Audible alarm
• Null pressure switch
• Firestat
• Purge timer
• Delay exhaust start
• 115 volt GFI service receptacle
• Marine service light with 100 wattbulb, guard, and lighted switch
• High density insulation
• 2" thick and 4" thick insulation
• Motor and bearings out of airstream
• Internal liners – 22 gauge solid or perforated
• JIC wiring
• Extended grease lines
• Belt guards
• Checker plate floor
• Walk-in service corridors
• Corrosion resistant two-step acrylic finish
• Special coatings
• Special construction: aluminum,stainless steel, heavier gauges
GIDM Series Temperature Control PackagesBuilding makeup air systems maintain a constant supply air temperature to the space using a discharge temperature controller. The burner output ismodulated over a wide range to compensate for fluctuations in the incoming ambient air temperature. A gas valve regulates output according to thedemand sensed by a discharge air sensor. The fan and heat system functions are typically controlled by a remote panel with a system andsummer/winter switch or a building management system.
Types of Gas Valve Control Available
A) Modulating Discharge Air Temperature ControlThis type consists of a discharge air sensor in the discharge of the unit. The temperature set point is set at the unit and the burner will then modulate tomaintain this discharge temperature.
B) Modulating Discharge Air Temperature Control with Remote Manual Adjustment (RTS)This type consists of a modulating discharge air sensor and a remote temperature selector. The operation of this type is the same as the above (A).However the discharge temperature may be remotely adjusted by the remote temperature selector.
C) Modulating Discharge Air Temperature Control with Remote Temperature Adjustment and Space Override (Brings Unit to Full Fire)This type consists of a modulating discharge air sensor, remote temperature selector, and a space override temperature stat. This is commonly usedwhere there is wide, fast indoor temperature fluctuations (eg. garage) and/or where fine temperature control is not essential, and/or when thetemperature rise is low (eg. 40 deg. F or less). The operation is the same as above (B) however when the space stat requires heat the furnace goes to fullfire regardless of the discharge temperature, until the space thermostat is satisfied.
D) Modulating Discharge Air Temperature Control with Remote Manual Adjustment (RTS'S) and Space Thermostat for Resetting Discharge Air Temperature SettingsThis type consists of a modulating discharge air sensor, a remote temperature selector for first temperature setting (eg. 75 deg. F), a second remotetemperature selector for Override setting (eg. 90 deg. F) and a space thermostat for switching. This type is used where there is moderate indoortemperature fluctuations and/or where fine temperature control is essential and/or when the unit temperature rise is high. The operation is the same as inC however the second remote temperature selector limits the discharge air temperature when the space thermostat calls for full fire. The burner willmodulate to maintain the second set point until the space thermostat is satisfied.
Note: The space stat may be replaced with dry contacts to allow a building management system to do the switching.
E) Building Management Control InterfaceThis type consists of a DDC Gas modulating interface (0-10Vdc or 4-20mA). This allows a building management system to tie into the unit controls. Thebuilding management system now controls the discharge temperature of the unit and the burner will modulate to maintain that temperature.
F) Modulating Space Thermostat with Auto Discharge Temperature ResetThis type consists of a modulating duct stat and a modulating space stat. This type is used where space loads continuously change. This system willautomatically adjust the discharge temperature to accommodate for the load changes providing precise space temperature control.
Miscellaneous Control Options
Freeze ProtectionSpecified to protect against untempered air entering the space. The freeze thermostat, also known as an auto low limit, is located in the discharge airand is wired in parallel with a time delay relay. In the event that the discharge air temperature is not above the freeze thermostat setting, within a presettime during start-up and under normal operation the unit will shut down.
Inlet Air ControllerFeatures an adjustable thermostat which monitors outdoor air temperatures. When the temperature exceeds the setting of the thermostat, the burner willnot operate even when the unit is in the winter mode.
Night SetbackThis feature is available as an option on all temperature control systems. By lowering the discharge air temperature requirements during unoccupiedperiods the owner can realize operating economies and still provide heat to the space as required. During the occupied cycle the unit will be brought onthough an interlock, timeclock or switch. During the unoccupied period the timeclock provided, switches the system control to a single stage thermostatset at the desired unoccupied temperature. The unit will then be started intermittently to provide heat to maintain the space at the unoccupiedtemperature setpoint.
5
Amperage Specifications
6
MOTORRUNNING MOTOR AMPERAGE
VOLTAGE/PHASE/CYCLES
HP 115/1/60 230/1/60 208/3/60 230/3/60 416/3/60 460/3/60 575/3/60
1/4 5.60 2.80 N/A N/A N/A N/A N/A
1/3 5.80 2.90 N/A N/A N/A N/A N/A
1/2 8.40 4.20 2.20 2.00 1.10 1.00 0.80
3/4 12.00 6.00 3.00 2.50 1.50 1.38 1.10
1 16.00 8.00 3.10 3.25 1.80 1.63 1.30
1 1/2 20.00 10.00 5.25 4.75 2.60 2.38 1.90
2 24.00 12.00 6.60 6.00 3.30 3.00 2.40
3 34.00 17.00 9.60 8.75 4.80 4.38 3.50
5 56.00 28.00 15.10 13.75 7.60 6.88 5.50
7 1/2 80.00 40.00 24.00 21.75 12.00 10.88 8.70
10 100.00 50.00 28.90 26.25 14.50 13.13 10.50
15 N/A N/A 44.20 40.00 22.10 20.00 16.00
20 N/A N/A 58.00 52.50 29.00 26.25 21.00
25 N/A N/A 74.50 67.50 37.30 33.75 27.00
30 N/A N/A 85.60 77.50 42.80 38.75 31.00
40 N/A N/A 115.90 105.00 58.00 52.50 42.00
50 N/A N/A 146.30 132.50 73.00 66.25 53.00
60 N/A N/A 165.60 150.00 82.80 75.00 60.00
75 N/A N/A 204.40 185.00 102.10 92.50 74.00
100 N/A N/A 270.50 245.00 135.20 122.50 98.00
125 N/A N/A 339.50 307.00 169.70 153.75 123.00
NOTES:
• To Calculate the Inrush Motor Amp. Draw = Running Motor Amperage x 2.5
• To Calculate the Full Load Amps (FLA) = 1.25 x Largest Motor Draw + Additional Motor Draw at Face Value + Control Amperage (1.00 Amps Generally Cover 90% of MUA Applications).
• If You Require Specific Control Amperages Please Contact the Factory.
NOTES:
• Accessory Static Pressure Drops are Calculated at Maximum CFM Loads.
ACCESSORIES STATIC PRESSURE DROP(IN INCHES WATER)
FLAT AND ANGULAR FILTER SECTION 0.4
INLET HOOD 0.1
INLET LOUVER 0.2
EVAPORATIVE COOLER (COMMERCIAL) 0.3
EVAPORATIVE COOLER (INDUSTRIAL) 0.4
INLET DAMPER 0.1
DX PLENUM AND COIL 0.6
WINTER FILTER (V-BANK) 0.6
NORMAL FILTER (V-BANK) 0.6
80/20 MIX BOX W/FILTERS 0.7
HORIZONTAL DISCHARGE HEAD 0.5
WAY DISCHARGE HEAD 0.5
Static Pressure Due to Accessories
7
Filter Section Summary
MODEL
STANDARD V-BANK HIGH CFM V-BANK
QUANTITY - SIZEINCHES
TOTAL FILTERFREE AREA
FT2
MAXIMUMAIR FLOW
CFMMODEL
QUANTITY - SIZEINCHES
TOTAL FILTERFREE AREA
FT2
MAXIMUMAIR FLOW
CFM
GIDM 20/25 3 - 2 x 25 x 20 10.42 5,210 GIDMH 20/25 4 - 2 x 20 x 25 19.44 9,7202 - 2 x 16 x 25
GIDM 35/40 4 - 2 x 25 x 20 13.88 6,940 GIDMH 35/40 4 - 2 x 20 x 25 25 12,5004 - 2 x 16 x 25
GIDM 45/55 4 - 2 x 20 x 25 19.44 9,720 GIDMH 45/55 12 - 2 x 20 x 25 41.67 20,8352 - 2 x 16 x 25
GIDM 65/75 6 - 2 x 20 x 25 26.39 13,195 GIDMH 65/75 15 - 2 x 20 x 25 52.08 26,0402 - 2 x 16 x 25
GIDM 85/100 9 - 2 x 20 x 25 39.58 19,790 GIDMH 85/100 20 - 2 x 20 x 25 69.4 34,7203 - 2 x 16 x 25
GIDM 125/175 16 - 2 x 20 x 25 66.67 33,335 GIDMH 125/175 30 - 2 x 20 x 25 104 52,0804 - 2 x 16 x 25
GIDM 200/250 20 - 2 x 20 x 25 80.56 40,280 GIDMH 200/250 48 - 2 x 20 x 25 166.6 83,3304 - 2 x 16 x 25
GIDM 275/325 30 - 2 x 20 x 25 118.06 59,030 GIDMH 275/325 48 - 2 x 20 x 25 189 94,4005 - 2 x 16 x 25 8 - 2 x 20 x 20
GIDM 350/400 35 - 2 x 20 x 25 135.42 67,710 GIDMH 350/400 60 - 2 x 20 x 25 263.9 131,9005 - 2 x 16 x 25 20 - 2 x 20 x 20
GIDM 500/600 48 - 2 x 20 x 25 183.33 91,665 GIDMH 500/600 80 - 2 x 20 x 25 361.11 180,5556 - 2 x 16 x 25 30 - 2 x 16 x 25
MODEL
STANDARD V-BANK HIGH CFM V-BANK
QUANTITY - SIZEINCHES
TOTAL FILTERFREE AREA
FT2
MAXIMUMAIR FLOW
CFMMODEL
QUANTITY - SIZEINCHES
TOTAL FILTERFREE AREA
FT2
MAXIMUMAIR FLOW
CFM
GIDM 20/25 1 - 2 x 20 x 25 3.47 1,735 GIDMH 20/25 2 - 2 x 20 x 25 9.72 4,8601 - 2 x 16 x 25
GIDM 35/40 2 - 2 x 20 x 25 6.94 3,470 GIDMH 35/40 6 - 2 x 16 x 20 13.3 6,665
GIDM 45/55 1 - 2 x 16 x 25 9.71 4,855 GIDMH 45/55 3 - 2 x 20 x 20 21.25 10,6252 - 2 x 20 x 25 3 - 2 x 16 x 20
1 - 2 x 20 x 25 1 - 2 x 16 x 25
GIDM 65/75 3 - 2 x 20 x 25 13.18 6,590 GIDMH 65/75 4 - 2 x 20 x 25 25 12,5001 - 2 x 16 x 25 4 - 2 x 16 x 25
GIDM 85/100 6 - 2 x 20 x 25 20.8 10,400 GIDMH 85/100 9 - 2 x 20 x 25 31.20 15,600
GIDM 125/175 12 - 2 x 16 x 25 33.3 16,650 GIDMH 125/175 12 - 2 x 20 x 25 41.665 20,833
GIDM 200/250 10 - 2 x 20 x 25 40.24 20,120 GIDMH 200/250 18 - 2 x 20 x 25 62.5 31,2502 - 2 x 16 x 25
GIDM 275/325 6 - 2 x 20 x 20 58.3 29,150 GIDMH 275/325 10 - 2 x 16 x 25 78.50 39,25012 - 2 x 20 x 25 14 - 2 x 20 x 25
1 - 2 x 16 x 20
GIDM 350/400 3 - 2 x 16 x 20 65 32,500 GIDMH 350/400 1 - 2 x 16 x 20 91.39 45,69512 - 2 x 20 x 25 21 - 2 x 20 x 256 - 2 x 20 x 20 4 - 2 x 16 x 25
GIDM 500/600 3 - 2 x 16 x 25 91.66 45,830 GIDMH 500/600 4 - 2 x 16 x 20 117.22 58,61024 - 2 x 20 x 25 4 - 2 x 20 x 20
28 - 2 x 20 x 25
MODEL
STANDARD V-BANK HIGH CFM V-BANK
QUANTITY - SIZEINCHES
TOTAL FILTERFREE AREA
FT2
MAXIMUMAIR FLOW
CFMMODEL
QUANTITY - SIZEINCHES
TOTAL FILTERFREE AREA
FT2
MAXIMUMAIR FLOW
CFM
GIDM 20/25 1 - 2 x 25 x 16 6.25 3,125 GIDM 125/175 12 - 2 x 20 x 25 50 25,0001 - 2 x 25 x 20 3 - 2 x 16 x 25
GIDM 35/40 1 - 2 x 16 x 25 11.25 5,625 GIDM 200/250 16 - 2 x 25 x 20 64.44 32,2201 - 2 x 16 x 20 4 - 2 x 16 x 201 - 2 x 20 x 201 - 2 x 20 x 25
GIDM 45/55 4 - 2 x 20 x 20 15.5 7,750 GIDM 275/325 24 - 2 x 20 x 20 75.56 37,7782 - 2 x 16 x 20 4 - 2 x 16 x 20
GIDM 65/75 6 - 2 x 20 x 20 21.11 10,555 GIDM 350/400 28 - 2 x 20 x 25 108.33 54,1652 - 2 x 16 x 20 4 - 2 x 16 x 25
GIDM 85/100 6 - 2 x 20 x 25 26.39 13,193 GIDM 500/600 40 - 2 x 20 x 25 152.78 76,3882 - 2 x 16 x 25 5 - 2 x 16 x 25
NOTES:
• The Static Pressure Drop Through the V-Bank Filters is Approximately 0.6 W.C. (Clean) and Approximately 1.00" W.C. (Dirty).
• The Maximum Airflow is Calculated so the Velocity Across the Filters Never Exceeds 500 FPM.
NOTES:
• The Static Pressure Drop Through the Flat and Angular Filters is Approximately 0.4" W.C (Clean) and Approximately 0.8" W.C. (Dirty).
• The Maximum Airflow is Calculated so the Velocity Across the Filters Never Exceeds 500 FPM.
GENERAL FILTER PERFORMANCE NOTES:
• The Standard Filter Selection May Contain One of the Three Types:
Replaceable: 2 Inch Fiberglass Media with an Average Efficiency of 20% at 500 FPM.
Throwaway: 2 Inch Pleated Media with an Average Efficiency of 30% at 500 FPM.
Permanent: 2 Inch Media with Layers of Slit and Expanded Aluminum. The Media Efficiency Averages 20% at 500 FPM. The Media can be Cleaned Using a Stream of Water
Weight Specifications (Pounds)
8
MODEL BLOWER SEC.HEAT
EXCHANGERSECTION
FLAT FILTERSECTION
V-BANKSECTION
MIX BOXWEATHERHOUSING
RETURN AIRBLOWER SEC.
GIDM 20/25 615 895 N/A 165 200 240 615
GIDM 35/40 755 1020 125 205 260 240 755
GIDM 45/55 950 1295 130 235 335 270 950
GIDM 65/75 1365 1560 130 295 420 270 1365
GIDM 85/100 1545 2125 140 320 495 300 1545
GIDM 125/175 2190 2840 305 360 710 350 2190
GIDM 200/250 2880 3445 375 440 935 425 2880
GIDM 275/325 3600 4590 400 465 1055 500 3600
GIDM 350/400 4145 5695 440 525 1250 650 4145
GIDM 500/600 5565 8935 670 795 1555 675 5565
Horizontal Units
MODEL BLOWER SEC.HEAT
EXCHANGERSECTION
FLAT FILTERSECTION
V-BANKSECTION
MIX BOXWEATHERHOUSING
RETURN AIRBLOWER SEC.
GIDM 20/25 665 845 N/A 165 200 240 615
GIDM 35/40 805 970 125 205 260 240 755
GIDM 45/55 1000 1245 130 235 335 270 950
GIDM 65/75 1425 1500 130 295 420 270 1365
GIDM 85/100 1635 2035 140 320 495 300 1545
GIDM 125/175 2300 2730 305 360 710 350 2190
GIDM 200/250 3000 3325 375 440 935 425 2880
GIDM 275/325 3740 4450 400 465 1055 500 3600
GIDM 350/400 4295 5545 440 525 1250 650 4145
GIDM 500/600 5885 8615 670 795 1555 675 5565
Vertical Units
MODEL INLET HOODRELIEFHOOD
DISCHARGENOZZLES
STANDARD
SERVICEPLATFORM
GIDM 20/25 60 40 75 585
GIDM 35/40 70 50 75 620
GIDM 45/55 90 50 100 690
GIDM 65/75 110 60 125 690
GIDM 85/100 160 60 125 730
GIDM 125/175 255 100 170 810
GIDM 200/250 315 110 215 835
GIDM 275/325 490 145 260 925
GIDM 350/400 575 160 300 1025
GIDM 500/600 710 170 450 1315
Accessories
9
MODEL BLOWER SEC.HEAT
EXCHANGERSECTION
FLAT FILTERSECTION
V-BANKSECTION
MIX BOXW/ RELIEF
MIX BOXW/ RELIEF
GIDM
GIDMH 20/25 860 910 N/A 250 390 220
GIDMH 35/40 1040 1035 190 315 500 290
GIDMH 45/55 1325 1340 200 380 505 380
GIDMH 65/75 1740 1625 200 440 785 480
GIDMH 85/100 1885 2160 200 450 880 580
GIDMH 125/175 2580 2885 415 485 1185 825
GIDMH 200/250 3375 3490 500 590 1550 1100
GIDMH 275/325 4120 4640 515 590 1705 1270
GIDMH 350/400 4715 5790 565 655 1940 1500
GIDMH 500/600 6185 9035 805 970 2385 1875
Horizontal Units
MODEL BLOWER SEC.HEAT
EXCHANGERSECTION
FLAT FILTERSECTION
V-BANKSECTION
MIX BOXW/ RELIEF
MIX BOXW/ RELIEF
GIDM
GIDMH 20/25 860 910 N/A 250 390 220
GIDMH 35/40 1040 1035 190 315 500 290
GIDMH 45/55 1325 1340 200 380 505 380
GIDMH 65/75 1740 1625 200 440 785 480
GIDMH 85/100 1885 2160 200 450 880 580
GIDMH 125/175 2580 2885 415 485 1185 825
GIDMH 200/250 3375 3490 500 590 1550 1100
GIDMH 275/325 4120 4640 515 590 1705 1270
GIDMH 350/400 4715 5790 565 655 1940 1500
GIDMH 500/600 6185 9035 805 970 2385 1875
Vertical Units
MODEL INLET HOODRELIEFHOOD
SERVICEPLATFORM
GIDMH 20/25 90 60 585
GIDMH 35/40 105 75 620
GIDMH 45/55 135 75 690
GIDMH 65/75 150 90 690
GIDMH 85/100 220 90 730
GIDMH 125/175 335 150 810
GIDMH 200/250 410 165 835
GIDMH 275/325 610 220 925
GIDMH 350/400 700 240 1025
GIDMH 500/600 855 255 1315
Accessories
Weight Specifications (Pounds)
GIDM Performance Specifications
10
GIDM 20 - 250 MBH INPUT/200 MBH OUTPUT
AirCapacity
(CFM)
4630 40 1.70 1.94 2.17 2.42 2.94 4.28
3704 50 1.47 1.67 1.87 2.08 2.49 2.90
3086 60 1.28 1.44 1.63 1.82 2.17 2.58
2646 70 0.90 1.06 1.22 1.37 1.73 2.13
2315 80 0.69 0.83 0.96 1.12 1.64 1.99
2058 90 0.55 0.67 0.82 0.97 1.39 1.72
1852 100 0.45 0.57 0.71 0.93 1.52 1.52
1684 110 0.39 0.51 0.7 0.87 1.05 1.24
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 25 - 312.5 MBH INPUT/250 MBH OUTPUT
AirCapacity
(CFM)
5787 40 2.91 3.19 3.48 3.77 4.37 4.99
4630 50 1.70 1.94 2.17 2.42 2.94 4.28
3858 60 1.62 1.82 2.02 2.24 2.67 3.09
3307 70 1.53 1.66 1.87 2.08 2.46 2.83
2894 80 1.09 1.27 1.44 1.61 1.95 2.37
2572 90 0.85 1.01 1.16 1.3 1.67 2.27
2315 100 0.69 0.83 0.96 1.12 1.64 1.99
2104 110 0.58 0.69 0.84 0.99 1.43 1.79
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 40 - 500 MBH INPUT/400 MBH OUTPUT
AirCapacity
(CFM)
9259 40 7.13 6.62 10.33 10.77 11.78 12.82
7407 50 3.59 4.00 5.22 5.56 6.27 7.00
6173 60 2.35 3.14 3.43 3.73 4.34 4.97
5291 70 1.96 2.21 2.47 2.73 3.28 3.84
4630 80 1.45 1.68 1.91 2.15 2.64 3.99
4115 90 1.12 1.33 1.54 1.76 2.80 3.26
3704 100 1.36 1.53 1.72 1.93 2.34 2.74
3367 110 1.08 1.26 1.44 1.63 1.99 2.81
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 35 - 437.5 MBH INPUT/350 MBH OUTPUT
AirCapacity
(CFM)
8102 40 4.49 4.93 5.37 5.82 6.73 7.66
6481 50 2.63 3.53 3.83 4.14 4.78 5.43
5401 60 2.06 2.32 2.58 2.85 3.40 3.97
4630 70 1.45 1.68 1.91 3.08 3.54 4.02
4051 80 1.09 2.00 2.19 2.40 2.81 3.24
3601 90 0.87 1.59 1.77 1.96 2.34 2.73
3241 100 1.16 1.32 1.72 1.89 2.22 2.55
2946 110 0.99 1.32 1.47 1.62 1.92 2.22
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 45 - 562.5 MBH INPUT/450 MBH OUTPUT
AirCapacity
(CFM)
10417 40 5.17 5.69 6.23 6.78 7.94 9.16
8333 50 4.13 4.57 5.02 5.48 6.40 8.31
6944 60 2.68 3.06 3.44 4.46 5.12 5.81
5952 70 1.90 2.66 2.94 3.22 3.81 4.42
5208 80 1.75 1.99 2.24 2.50 3.03 3.58
4630 90 1.34 1.57 1.80 2.03 2.52 3.04
4167 100 1.07 1.28 2.09 2.32 2.77 3.24
3788 110 1.39 1.54 1.74 1.93 2.37 3.39
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 55 - 687.5 MBH INPUT/550 MBH OUTPUT
AirCapacity
(CFM)
12731 40 7.24 7.98 8.79 9.61 11.40 19.59
10185 50 4.90 5.41 5.94 6.48 7.62 10.68
8488 60 4.31 4.77 5.22 5.68 6.62 7.57
7275 70 2.98 3.38 3.77 4.17 4.99 5.83
6366 80 2.21 3.12 3.40 3.70 4.32 4.96
5658 90 1.71 2.38 2.64 2.92 3.48 4.06
5093 100 1.66 1.90 2.15 2.40 2.92 3.52
4630 110 1.34 1.57 1.80 2.77 3.23 3.70
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 65 - 812.5 MBH INPUT/650 MBH OUTPUT
AirCapacity
(CFM)
12037 50 5.82 6.39 6.97 7.57 8.79 10.03
10031 60 3.73 4.22 4.72 7.31 8.31 9.32
8598 70 2.64 4.47 4.89 5.32 6.19 7.09
7523 80 2.00 3.36 3.74 4.12 4.91 5.72
6687 90 2.34 2.67 3.53 3.87 4.56 5.24
6019 100 1.91 2.59 2.90 3.21 3.83 4.53
5471 110 1.89 2.17 2.45 2.73 3.29 4.85
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 75 - 937.5 MBH INPUT/750 MBH OUTPUT
AirCapacity
(CFM)
13889 50 8.39 9.02 8.82 10.35 11.72 13.12
11574 60 5.27 5.82 6.39 6.96 8.14 9.35
9921 70 3.64 4.13 4.62 5.13 6.18 8.94
8681 80 2.70 4.37 4.79 5.22 6.11 7.01
7716 90 2.11 3.35 3.74 4.13 4.93 5.76
6944 100 2.33 2.67 3.03 3.39 4.13 5.39
6313 110 1.89 2.65 2.97 3.29 3.94 4.58
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
NOTES:
• All Static Values Include the Blower, Burner, and Casing
• Accessory Static Values Must be Added to Obtain the Total Static (see pg. 5)
• Brake Horsepower Does Not Include Drive Losses
Consult factory for:
• Higher Air Capacities or Special Applications
• Performance Data on Higher Statics than Listed
• Performance Data at Elevations Other Than Sea Level
11
GIDM 175 - 2187.5 MBH INPUT/1750 MBH OUTPUT
AirCapacity
(CFM)
32407 50 21.80 23.34 24.90 26.50 29.79 33.22
27006 60 13.62 17.11 18.35 19.61 22.19 24.88
23148 70 10.76 11.82 12.91 14.02 16.35 18.79
20255 80 7.77 8.72 9.70 10.72 12.86 15.14
18004 90 5.91 6.78 10.40 11.36 13.31 15.29
16204 100 4.70 7.48 8.35 9.22 11.00 12.80
14731 110 3.85 6.10 6.90 7.70 9.33 11.00
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1 1/2
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 85 - 1062.5 MBH INPUT/850 MBH OUTPUT
AirCapacity
(CFM)
19676 40 12.83 13.87 14.93 15.99 18.13 20.30
15741 50 7.35 8.20 9.05 9.91 11.67 13.45
13117 60 4.82 5.54 7.36 7.98 9.25 10.56
11243 70 3.46 4.75 5.29 5.84 6.96 8.13
9838 80 3.10 3.57 4.05 4.54 5.56 8.49
8745 90 2.41 2.84 4.74 5.16 6.04 7.95
7870 100 1.94 3.55 3.84 4.23 5.04 5.87
7155 110 1.61 2.86 3.21 3.58 4.33 5.68
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 100 - 1250 MBH INPUT/1000 MBH OUTPUT
AirCapacity
(CFM)
23148 40 17.14 18.22 19.33 20.43 22.71 25.00
18519 50 10.97 11.96 12.96 13.96 15.99 18.04
15432 60 7.02 7.85 8.69 9.54 11.26 13.02
13228 70 4.89 5.62 7.49 8.10 9.38 10.70
11574 80 3.66 5.05 5.60 6.16 7.31 8.50
10288 90 3.45 3.93 4.43 4.94 5.99 9.03
9259 100 2.72 3.17 3.63 5.58 6.49 7.44
8418 110 2.22 2.64 4.17 4.59 5.44 6.32
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1 1/4
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 125 - 1562.5 MBH INPUT/1250 MBH OUTPUT
AirCapacity
(CFM)
28935 40 16.22 17.62 19.04 20.51 23.54 26.74
23148 50 10.76 11.82 12.91 14.02 16.35 18.79
19290 60 6.92 7.84 12.09 13.12 15.20 17.30
16534 70 4.90 7.81 8.70 9.59 11.39 13.23
14468 80 5.10 5.87 6.65 7.45 9.05 10.70
12860 90 3.97 4.66 6.51 7.08 8.31 9.59
11574 100 3.21 4.68 5.20 5.75 6.89 8.07
10522 110 2.65 3.80 4.30 4.81 5.87 6.97
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1 1/4
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 150 - 1875 MBH INPUT/1500 MBH OUTPUT
AirCapacity
(CFM)
34722 40 24.50 28.64 29.94 31.31 34.04 36.90
27778 50 14.66 18.40 19.66 20.95 23.59 26.33
23148 60 10.76 11.82 12.91 14.02 16.35 18.79
19841 70 7.39 8.32 9.29 13.93 16.05 18.21
17361 80 5.46 6.30 9.63 10.57 12.45 14.37
15432 90 4.23 6.72 7.55 8.39 10.09 11.82
13889 100 4.68 5.43 6.18 8.34 9.63 10.98
12626 110 3.81 4.49 6.24 6.81 8.03 9.28
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1 1/2
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 200 - 2500 MBH INPUT/2000 MBH OUTPUT
AirCapacity
(CFM)
46296 40 22.66 24.60 26.59 28.65 33.03 43.86
37037 50 16.18 17.89 19.64 21.46 25.24 29.26
30864 60 10.50 11.98 18.83 20.30 23.32 26.48
26455 70 7.48 12.13 13.40 16.70 19.16 21.73
23148 80 7.95 10.46 11.52 12.60 14.84 17.21
20576 90 6.12 8.05 9.01 10.01 12.10 14.33
18519 100 5.62 6.47 7.37 8.30 13.24 15.26
16835 110 4.56 5.36 8.41 9.31 11.14 13.00
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
1 1/2
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 250 - 3125 MBH INPUT/2500 MBH OUTPUT
AirCapacity
(CFM)
57870 40 35.59 38.28 41.04 43.88 49.81 56.07
46296 50 22.66 24.60 26.59 28.65 33.03 43.86
38580 60 17.89 19.67 21.48 23.34 27.23 31.34
33069 70 12.31 13.87 22.10 23.65 26.84 30.14
28935 80 9.08 14.91 16.28 17.67 20.56 23.60
25720 90 7.08 11.42 14.56 15.74 18.15 20.67
23148 100 7.95 10.46 11.52 12.60 14.84 17.21
21044 110 6.43 8.46 9.44 10.45 12.56 14.82
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
2
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
NOTES:
• All Static Values Include the Blower, Burner, and Casing
• Accessory Static Values Must be Added to Obtain the Total Static (see pg. 5)
• Brake Horsepower Does Not Include Drive Losses
Consult factory for:
• Higher Air Capacities or Special Applications
• Performance Data on Higher Statics than Listed
• Performance Data at Elevations Other Than Sea Level
GIDM Performance Specifications
GIDM Performance Specifications
12
GIDM 275 - 3437.5 MBH INPUT/2750 MBH OUTPUT
AirCapacity
(CFM)
50926 50 25.65 27.71 29.79 31.90 36.30 40.99
42438 60 16.62 22.96 24.90 26.86 30.92 38.36
36376 70 14.36 16.02 17.72 19.47 23.14 27.04
31829 80 10.18 11.65 18.78 20.25 23.28 26.43
28292 90 8.08 9.44 14.93 16.28 19.10 22.07
25463 100 6.52 10.76 11.98 15.01 17.39 19.87
23148 110 7.65 8.75 11.22 12.30 14.52 16.87
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
2
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 300 - 3750 MBH INPUT/3000 MBH OUTPUT
AirCapacity
(CFM)
55556 50 28.02 30.52 33.08 35.71 41.22 47.07
46296 60 20.61 22.51 24.44 26.43 30.62 35.17
39683 70 14.12 19.58 21.41 23.27 27.15 31.23
34722 80 12.89 14.48 16.12 17.82 21.40 25.22
30864 90 9.81 11.26 18.13 19.59 22.58 25.71
27778 100 7.77 13.03 14.34 15.68 18.46 21.40
25253 110 6.38 10.53 13.56 14.71 17.08 19.55
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
2 1/2
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 325 - 4062.5 MBH INPUT/3250 MBH OUTPUT
AirCapacity
(CFM)
60185 50 34.40 37.07 39.79 42.58 48.37 54.48
50154 60 25.26 27.31 29.38 31.48 35.86 40.52
42989 70 17.13 18.91 20.73 27.59 31.68 35.96
37616 80 15.59 17.30 19.04 20.84 24.58 28.55
33436 90 11.78 13.32 14.92 23.37 26.55 29.85
30093 100 9.29 10.72 17.15 18.58 21.52 24.60
27357 110 7.55 12.62 13.91 17.52 20.03 22.64
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
2 1/2
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 350 - 4375 MBH INPUT/3500 MBH OUTPUT
AirCapacity
(CFM)
81019 40 48.29 51.64 55.00 58.39 65.33 72.56
64815 50 29.42 32.21 35.04 37.92 43.92 54.90
54012 60 21.86 24.20 26.59 29.04 34.15 39.61
46296 70 15.21 20.08 21.98 23.90 27.90 32.21
40509 80 13.18 14.84 20.55 22.41 26.24 30.27
36008 90 10.07 14.39 16.05 17.74 21.30 25.10
32407 100 10.02 11.50 13.02 20.82 23.90 27.09
29461 110 8.12 9.49 15.60 16.98 19.85 22.85
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
2 1/2
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 400 - 5000 MBH INPUT/4000 MBH OUTPUT
AirCapacity
(CFM)
92593 40 CONSULT FACTORY
74074 50 41.31 44.50 47.68 50.90 57.47 64.32
61728 60 26.05 28.72 35.91 38.63 44.22 40.07
52910 70 20.86 23.16 25.51 27.92 32.99 38.40
46296 80 15.21 20.08 21.98 23.90 27.90 32.21
41152 90 13.69 15.37 21.28 23.16 27.04 31.11
37037 100 10.72 15.30 16.99 18.72 22.34 26.19
33670 110 10.90 12.43 14.00 15.62 25.81 22.73
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
3
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 500 - 6250 MBH INPUT/5000 MBH OUTPUT
AirCapacity
(CFM)
115741 40 139.7
92593 50 77.06 84.76
77160 60 42.40 49.27 55.92 62.71
66138 70 29.63 32.48 40.88 46.66 52.60
57870 80 19.47 21.95 28.17 41.38 35.91 41.38
51440 90 14.86 19.69 21.95 28.06 32.30 36.69
46296 100 13.76 15.77 20.61 28.34 32.55 36.87
42088 110 11.13 15.11 16.84 23.11 27.01 31.07
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
3
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
GIDM 600 - 7500 MBH INPUT/6000 MBH OUTPUT
AirCapacity
(CFM)
138889 40
111111 50 127.1
92593 60 77.06 84.76
79365 70 45.35 52.60 59.43 66.37
69444 80 30.61 36.18 37.17 45.24 51.58
61728 90 20.87 25.31 32.48 35.16 40.61 46.29
55556 100 17.69 23.37 25.78 33.23 37.78 42.41
50505 110 14.24 18.89 24.88 26.95 31.12 35.47
Temp.Rise
0.25"W.C.
BHP BHP BHP BHP BHP BHP
3
0.5"W.C.
0.75"W.C.
1.0"W.C.
1.5"W.C.
2.0"W.C.
GasConn.Inches
NOTES:
• All Static Values Include the Blower, Burner, and Casing
• Accessory Static Values Must be Added to Obtain the Total Static (see pg. 5)
• Brake Horsepower Does Not Include Drive Losses
Consult factory for:
• Higher Air Capacities or Special Applications
• Performance Data on Higher Statics than Listed
• Performance Data at Elevations Other Than Sea Level
CONSULT FACTORY, REQUIRESFAN SIZE GREATER THAN2-36x36
CONSULT FACTORY, REQUIRESFAN SIZE GREATER THAN2-36x36
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 13
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
P
FILTERSFRESH AIR
DAMPER
POWER BURNER
UI
D K
UI
FRESH AIRFLOW
SUPPLY AIROPTION
PUFFDOOR
SIDE VIEW
OPTIONSUPPLY AIR
SPRING ISOLATOR
M
T
BLOWERSC
A B
G
COM
BUST
ION
PATH
PANELCONTROL
SUPPLY AIROPTION
TOP VIEW
FOUR PASSCOMBUSTION CHAMBER
L
U
H
W
NMIN.
CLEARANCE
UI
U
O
3
V
FLEXCONN.
4TYP.
Z HINGED DOORACCESS c/wHANDLE
A
UNITS UP TO GIDM 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECE SHIPPING
NOTES:
A SIZE 65/75 AND UP SPLIT FOR SHIPMENT
MOTOR
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
72GIDM 125/175 75
GIDM 500/600
GIDM 350/400
GIDM 275/325
GIDM 200/250
87
107
92
80
84
100
141
72
GIDM 45/55
GIDM 35/40
GIDM 20/25
GIDM 85/100
GIDM 65/75
MODEL
68
62
67
60
62
55
47
55
52
A
47
B
9154100 413091 2432
140
160
180
120
65
80
70
60
36
36
36
36
131
168
148
111
32
32
32
32
30
48
30
30 111
168
148
131 52
67
57
47
80
80
60
48
48
36
36
32
32
C
32
D
30
30
30
30
71
71
51
39
30
G
23
H
20
20
20
18
18
18
18
18
18
I
18
K
71
71
51
39
35
23
23
19
23
L
19
M
121590 12
16
20
15
140
120
120
120
-
-
12
12
14
14
6
6
9
9
15
7
7
O
40
40
70
80
40
N
18
18
18
12
18
P
12
12
12
10
10
T U
124
2
6
6
4
4 14
18
16
12
2
4
3
3
3
12
10
10
8
3
V
8
W Z
17 12
11 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNITGRAVITY VENTED c/w ANGULAR FILTER SECTION
TITLE
14NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
PFILTERSFRESH AIR
DAMPER
POWER BURNER
UI
D K
UI
FRESH AIRFLOW
SUPPLY AIROPTION
PUFFDOOR
SIDE VIEW
OPTIONSUPPLY AIR
SPRING ISOLATOR
M
T
BLOWERSC
A B
G
COM
BUST
ION
PATH
PANELCONTROL
SUPPLY AIROPTION
TOP VIEW
FOUR PASSCOMBUSTION CHAMBER
L
U
H
W
NMIN.
CLEARANCE
UI
U
O
3
V
FLEXCONN.
4TYP.
Z HINGED DOORACCESS c/wHANDLE
A
UNITS UP TO GIDM 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECE SHIPPING
NOTES:
A SIZE 65/75 AND UP SPLIT FOR SHIPMENT
MOTOR
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
72GIDM 125/175 75
GIDM 500/600
GIDM 350/400
GIDM 275/325
GIDM 200/250
87
107
92
80
84
100
141
72
GIDM 45/55
GIDM 35/40
GIDM 20/25
GIDM 85/100
GIDM 65/75
MODEL
68
62
67
60
62
55
47
55
52
A
47
B
9154100 413091 2432
140
160
180
120
65
80
70
60
36
36
36
36
131
168
148
111
32
32
32
32
30
48
30
30 111
168
148
131 52
67
57
47
80
80
60
48
48
36
36
32
32
C
32
D
30
30
30
30
71
71
51
39
30
G
23
H
20
20
20
18
18
18
18
18
18
I
18
K
71
71
51
39
35
23
23
19
23
L
19
M
121590 12
16
20
15
140
120
120
120
-
-
12
12
14
14
6
6
9
9
15
7
7
O
40
40
70
80
40
N
18
18
18
12
18
P
12
12
12
10
10
T U
124
6
6
4
4 14
18
16
12
2
2
4
3
3
3
12
10
10
8
3
V
8
W Z
17 12
11 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 15
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w V-BANK FILTER SECTION
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
NMIN.
CLEARANCE
A
G
POWER BURNERFRESH AIR
DAMPER
DFRESH AIRFLOW
M
SPRING ISOLATOR
MOTOR
FILTERS
U
CL BLOWERS
P
K
SUPPLY AIROPTION
PUFFDOOR
I
I
PANELCONTROL
U
U
SUPPLY AIROPTION
SUPPLY AIROPTION
H
COM
BUST
ION
PATH
W
IB
FOUR PASSCOMBUSTION CHAMBER
U
TOP VIEW
SIDE VIEW
U
4TYP.
Z
OV
3
FLEXCONN.
HINGED DOORACCESS c/wHANDLE
A
UNITS UP TO GIDM 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECE SHIPPING
NOTES:
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT.
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
39
23
71
51
91
71
131
168
148
111
141
100
GIDM 200/250
GIDM 500/600
GIDM 350/400
GIDM 275/325
92
95
117
101
GIDM 125/175
GIDM 45/55
GIDM 35/40
GIDM 20/25
GIDM 85/100
GIDM 65/75
MODEL
68
67
72
85
75
A
62
84
72
160
180
120
140
70
80
60
65
36
36
36
36
148
168
111
131
32
32
32
32 30
30
48
30
47 48
72
62
55
55
100
80
60
80
B
47
C
32
32 30
54
48
36
36
32
30
30
30
D
32
G
30
39 18
91
71
51
71
30
20
20
20
H
23
I
18
18
18
18
24
18
18
K
3
V
3
3
4
4
3
4
4
6
667
57
52
47
120
140
120
120
20
16
15
-
-
12
12
14 6
6
19
41
35
23
23
L M
19
40 7
90
80
40
70
15
15
9
9
N
40
O
7
18 10
12
12
18
18
12
14
12
12
12
P
18
T
10
U
2
2
12
14
18
16
Z
8
10
10
12
12
8
W
T
17 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
11 12
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNITGRAVITY VENTED c/w V-BANK FILTER SECTION
TITLE
16NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
TOP VIEW
FOUR PASSCOMBUSTION CHAMBER
B
SIDE VIEW
POWER BURNER
D
FRESH AIRFLOW
M
SPRING ISOLATOR
FILTERSFRESH AIR
DAMPER
A
U
MOTOR
BLOWERS
K
T
U
U
I
I
OPTIONSUPPLY AIR
SUPPLY AIROPTION
PUFFDOOR
PANELCONTROL
SUPPLY AIROPTION
COM
BUST
ION
PATH
NMIN.
CLEARANCE
U
H
W
A
G
I
P
O
M
19
23
19
35
47
52
23
57
67
84 72GIDMH 125/175
GIDMH 200/250
GIDMH 275/325
GIDMH 350/400
GIDMH 500/600
95
102
98
90
84
141
100
72
GIDMH 65/75
GIDMH 85/100
GIDMH 20/25
GIDMH 35/40
GIDMH 45/55
MODEL
60
55
60
55
55
62
47
55
52
A
47
B
123 412491 3060 32132
176
216
196
156
71
76
86
66
36
36
36
36
131
171
151
111
32
32
42
32
35
30
48
30 147
167
184
204
110
110
90
78
54
42
42
38
C
62
D
38
30
30
30
30
71
71
51
39
30
G
23
H
20
20
20
18
18
18
18
18
18
I
18
K
101
101
81
69
53
L
12618100
20
21
140
140
140
140 -
-
6
6
14
14
6
O
9
11
9
18
12
40
40
80
60
N
40
12
12
4
8
12
P
12
12
12
10
10
T U
4
4
6
6
4
14
16
18
12
12
2
2
4
3
3
3
12
10
10
8
3
V
8
W Z
U
V
3
FLEXCONN.
4TYP.
ZHINGED DOORACCESS c/wHANDLE
NOTES:
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT
UNITS UP TO GIDM 45/55 WILL HAVETURNED BASE RAILS TO ALLOW FOR 1 PIECESHIPPING.
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
C
L
17 12
27 12 11 1
2
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
6 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 17
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w ANGULAR FILTER SECTION AND MIX BOX
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
TOP VIEW
SIDE VIEW
I
I
U
U
K
T
D
SUPPLY AIR
POWER BURNER
RETURN AIROPTION
RETURN AIROPTION
SUPPLY AIR
PUFFDOOR
CONTROLPANEL
OPTION
OPTIONSUPPLY AIR
V
3
FRESH AIRDAMPER
M
SPRING ISOLATOR
FILTERS
MOTOR
P
FRESH AIRFLOW
OPTION
72GIDM 125/175 75
GIDM 500/600
GIDM 350/400
GIDM 275/325
GIDM 200/250
87
107
92
80
84
100
141
72
GIDM 45/55
GIDM 35/40
GIDM 20/25
GIDM 85/100
GIDM 65/75
MODEL
68
62
67
60
62
55
47
55
52
A
47
B
9154100 413091 2432
140
160
180
120
65
80
70
60
36
36
36
36
131
168
148
111
32
32
32
32
30
48
30
30 111
168
148
131 52
67
57
47
80
80
60
48
48
36
36
32
32
C
32
D
30
30
30
30
71
71
51
39
30
G
23
H
20
20
20
18
18
18
18
18
18
I
18
K
71
71
51
39
35
23
23
19
23
L
19
M
121590 14739 12
44
44
41
41
16
20
15
140
120
120
120
-
-
12
12 171
248
192
153
14
14
6
6
29
29
29
27
27
Q
9
9
15
7
7
O
40
40
70
80
40
N
18
18
18
12
18
P
130
117
107
122
99
S
12
12
12
10
10
T U
124
6
6
4
4 14
18
16
12
2
2
4
3
3
3
12
10
10
8
3
V
8
W Z
O
FLEXCONN.
NOTES:
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT
UNITS UP TO GIDM 45/55 WILL HAVETURNED BASE RAILS TO ALLOW 1 PIECESHIPPING
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
SECTIONMIX BOX
COM
BUST
ION
PATH
BLOWERS
G
C
FOUR PASSCOMBUSTION CHAMBER
L
U
S
NMIN.
CLEARANCE
W
A BQ
U
4TYP.
Z
HINGED DOORACCESS c/wHANDLE
AA
H
U I
17 12
11 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND MIX BOX
TITLE
18NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
TOP VIEW
SIDE VIEW
I
UI
U
K
G
A
C
D
B
FRESH AIRFLOW
SUPPLY AIR
POWER BURNER
RETURN AIROPTION
RETURN AIROPTION
SUPPLY AIROPTION
PUFFDOOR
CONTROLPANEL
OPTION
OPTIONSUPPLY AIR
FOUR PASSCOMBUSTION CHAMBER
COM
BUST
ION
PATH
V
3
U
L
U
FRESH AIRDAMPER
M
SPRING ISOLATOR
FILTERSP
T
S
IN
MIN.CLEARANCE
BLOWERS
Q
H
W
U
4TYP.
Z
O
RETURN AIRDAMPER
MOTOR
FLEXCONN.
HINGED DOORACCESS c/wHANDLE
AA
UNITS UP TO GIDM 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECE SHIPPING
NOTES:
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT
SECTIONMIX BOX
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
GIDM 125/175
GIDM 200/250
GIDM 275/325
GIDM 350/400
GIDM 500/600
GIDM 65/75
GIDM 85/100
GIDM 20/25
GIDM 35/40
GIDM 45/55
M
19
19
23
23
35
47
57
67
52
75 72
107
92
80
87
141
100
72
84
MODEL
62
68
67
60
55
62
55
47
52
A
47
B
32 2491 30100 54 91 41
180
160
120
140
70
80
60
65
36
36
36
36
148
168
111
131
32
32
32
32
48
30
30
30 131
148
168
111
80
80
48
60
36
48
32
36
C
32
D
32
30
30
30
30
71
71
39
51
30
G
23
H
20
20
20
18
18
18
18
18
18
I
18
K
39
71
71
51
23
L
1239 14790 15 12
15
20
16
120
120
120
140
12
12
-
-
44
44
41
41
248
192
153
171
14
14
6
6
7
7
1580
70
40
40
N
40
12
18
18
189
9
18
O P
29
29
29
27
117
130
122
107
27
Q
99
S
12
12
12
10
10
T U
4 12
6
6
4
4
16
18
12
14
2
2
4
3
3
3
12
10
10
8
3
V
8
W Z
17 12
11 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 19
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND MIX BOX
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
TOP VIEW
SIDE VIEW
I U
UI
K
G
A
C
D
V
B
FRESH AIRFLOW
SUPPLY AIR
POWER BURNER
RETURN AIROPTION
RETURN AIROPTION
SUPPLY AIROPTION
PUFFDOOR
CONTROLPANEL
OPTION
OPTIONSUPPLY AIR
FOUR PASSCOMBUSTION CHAMBER
COM
BUST
ION
PATH
FRESH AIRDAMPER
FILTERS
SPRING ISOLATOR
M
3
T
S
L
MOTOR
BLOWERS
Q
U I
H
NMIN.
CLEARANCE
W
P
O
TURNED BASE RAILS TO ALLOW FOR 1 PIECEUNITS UP TO GIDMH 45/55 WILL HAVE
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT
SHIPPING
NOTES:
110
110
132
156
176
196
216
GIDMH 45/55
GIDMH 85/100
GIDMH 65/75
GIDMH 275/325
GIDMH 500/600
GIDMH 350/400
GIDMH 200/250
GIDMH 125/175
47
50
57
60
65
68
77
84
100
141
55
62
72
72
GIDMH 35/40
GIDMH 20/25
40
37
47
47
47
55
62
78
90
86
76
71
36
36
36
66
60
54
42
36
32
30
30
171
151
131
42
32
32
111
91
71
71
32
30
20
20
48
35
30
204
184
167
24
30
18
18
147
123
101
101
67
52
57
140
140
140
41
47
23
35
140
100
60
80
38
38
42
30
30
30
23
39
51
18
18
20
18
18
18
53
69
81
19
19
23
40
40
40
21
20
-
-
18
12
18
6
6
6
4
8
149
168
21344
44
41
97
112
129
13341
39
29
29 3
4
4
4
6
4
614
14
6
12
12
12
18
16
14
12
12
12
10
9
9
11
12
12
12
87
84
102
27
27
29
3
3
3
10
10
12
8
8
10
2
2
U U
RETURN AIRDAMPER
FLECCONN.
4TYP.
Z
AA
SECTIONMIX BOX
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
MODEL A B C D G H I K L M N O P Q S VT U W Z
17 12
27 12 11 1
2
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
6 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w V-BANK FILTER SECTION AND MIX BOX
TITLE
20NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
TOP VIEW
SIDE VIEW
UI
UI
K
G
A
C
D
B
FRESH AIRFLOW
POWER BURNER
RETURN AIROPTION
RETURN AIROPTION
SUPPLY AIROPTION
PUFFDOOR
CONTROLPANEL
SUPPLY AIROPTION
OPTIONSUPPLY AIR
FOUR PASSCOMBUSTION CHAMBER
COM
BUST
ION
PATH
V
3
U
U
FRESH AIRDAMPER
M
L
SPRING ISOLATOR
FILTERS P
T
S
I
NMIN.
CLEARANCE
BLOWERS
Q
H
W
GIDM 500/600
GIDM 350/400 100
141
101
117
160
180 80
70
36
36
GIDM 45/55
GIDM 35/40
GIDM 20/25
GIDM 125/175
GIDM 85/100
GIDM 275/325
GIDM 200/250
GIDM 65/75
47
55
47
62
72
84
72
5567
85
92
95
75
MODEL
68
72
62
A
3080 36
100
140
120
80
3254
65
60
36
36
48 30
48
60
B
32
C
3032
36 30
32
D
30
G
32148
168 32 48
30
168
148
67
57 120
140
201
25816 -
-
44
44
14
14
6 6
6
71 20 18
20
32
32
3091
111
131
71
24
30
30
18
20
39
51
H
23
18 18
18
18
I
18
K
71 23 70
4191
131
111
52
47
71 35
90
120
120
80
1939
51 23
23
L
19
M
40
40
40
N
109
115
127
137
165
179
157
1229 29
15
15
39
41
41
29
7
12
9
12
7
O
18
P
27
29
27
Q S
12 3
12
12
4
4
4
4
10
12
10
T
3
3
U
3
V
18
16
2
2
10
12
14
12
12
10
8
8
W Z
U
O
4TYP.
Z
MOTOR
FLEXCONN.
RETURN AIRDAMPER
HINGED DOORACCESS c/wHANDLE
AA
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT.
15
20
12
12
18
18
18
6
NOTES:
UNITS UP TO GIDM 45/55 WILL HAVETURNED BASE RAILS TO ALLOW 1 PIECESHIPPING
SECTIONMIX BOX
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
17 12
11 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 21
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w V-BANK FILTER SECTION AND MIX BOX
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
NMIN.
CLEARANCE
SUPPLY AIRD
Q
C
I
UI
U
K
A B
FRESH AIRFLOW
SUPPLY AIR
POWER BURNER
RETURN AIROPTION
RETURN AIROPTION
OPTIONSUPPLY AIR
PUFFDOOR
OPTION
CONTROLPANEL
OPTION
FOUR PASSCOMBUSTION CHAMBER
COM
BUST
ION
PATH
V
SPRING ISOLATOR
M
3
FRESH AIRDAMPER
FILTERS
T
BLOWERS
L
MOTOR
H
W
G
SIDE VIEW
TOP VIEW
P
O
GIDMH 500/600
GIDMH 350/400 100
141
98
102
196
216 86
76
36
36
GIDMH 45/55
GIDMH 35/40
GIDMH 20/25
GIDMH 125/175
GIDMH 85/100
GIDMH 275/325
GIDMH 200/250
GIDMH 65/75
47
55
47
62
72
84
72
5555
84
90
95
65
MODEL
55
60
52
A
30110 42
132
176
156
110
3260
71
66
36
36
54 30
78
90
B
62
C
3038
42 30
38
D
30
G
32151
171 42 48
30
204
184
67
57 140
140
198
24321 -
-
44
44
14
14
6 6
6
71 20 18
20
32
32
3091
111
131
71
24
35
30
18
20
39
51
H
23
18 18
18
18
I
18
K
101 23 60
41123
167
147
52
47
101 35
100
140
140
80
1969
81 23
53
L
19
M
40
40
40
N
99
102
115
122
163
179
156
110812 29
18 6
20
6
6
18 4
39
41
41
29
9 12
11 12
9
O
12
P
27
29
27
Q S
12 3
12
12
4
4
4
4
10
12
10
T
3
3
U
3
V
18
16
2
2
10
12
14
12
12
10
8
8
W Z
S
UU
U I
RETURN AIRDAMPER
HINGED DOORACCESS c/w
HANDLE
A A
FLEXCONN.
4TYP.
Z
A SIZE 65/75 AND UP SPLIT FOR SHIPMENT
NOTES:
UNITS UP TO GIDMH 45/55 WILL HAVETURNED BASE RAILS TO ALLOW 1 PIECESHIPPING
SECTIONMIX BOX
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
17 12
27 12 11 1
2
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
6 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND DX COIL
TITLE
22NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
OPTIONSUPPLY AIR
I U
UI
K
G
A
C
D
B
FRESH AIRFLOW
POWER BURNER
SUPPLY AIROPTION
OPTION
PUFFDOOR
CONTROLPANEL
FOUR PASSCOMBUSTION CHAMBER
COM
BUST
ION
PATH
SUPPLY AIR
U
DXCOIL
DRAINPAN
SPRING ISOLATOR
YM
FRESH AIRDAMPER
BLOWERS
T
P
NMIN.
CLEARANCE
XL H
W
I U
SIDE VIEW
TOP VIEW
100
141
102GIDM 275/325
GIDM 350/400
GIDM 500/600
102
94
GIDM 65/75
GIDM 85/100
GIDM 20/25
GIDM 35/40
GIDM 45/55
GIDM 125/175
GIDM 200/250
MODEL
98
102
92
100
82
A
97
90
3032131366514084
36
36180
160
80
70
168
148
32
32
48
30
30
30
30
30
30
36
32
72
72
62
55
120
100
80
80
55
47
47
B
48
60
32
C
60
54
36
48
36
32
32
D G
71
71
91
111
23
H
51
39
32
30
20
20
30
24
18
18
20
18
18
I
18
18
18
K U
6
6
1212052131
57
67168
148
140
120
16
20 -
- 14
14
19
19
23
23
35
47
M
111
91
71
71
41
51
39
23
L
70
80
90
120
40
40
40
N
15
15
15
9
12
12
18
12
9
7
7
O
18
18
18
P
12
12
12
12
10
10
T
144
6
6
18
16
2
2
4
4
4
3
V
3
3
3
12
12
12
10
10
8
8
W Z
125
145
165
65
102
85
65
X
23
45
22
56
71
61
27
39
45
51
23
27
23
Y
U
OV
3
FLEXCONN.
FILTERS
AHINGED DOORACCESS c/w
HANDLE (typ)
4TYP.
Z
NOTES:
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT
UNITS UP TO 45/55 WILL HAVETURNED BASE RAILS TO ALLOW 1 PIECESHIPPING
SECTIONBLOWER/FILTER/COIL
SECTIONHEAT EXCHANGER
17 12
11 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 23
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND DX COIL
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
SIDE VIEW
V
I
I
U
U
K
A
C
D
B
FRESH AIRFLOW
SUPPLY AIR
POWER BURNER
SUPPLY AIROPTION
PUFFDOOR
CONTROLPANEL
OPTION
OPTIONSUPPLY AIR
FOUR PASSCOMBUSTION CHAMBER
COM
BUST
ION
PATH
SPRING ISOLATOR
M
3
FRESH AIRDAMPER
YT
DXCOIL
DRAINPAN
X
BLOWERS
L
MOTOR
U
H
W
G NMIN.
CLEARANCE
UI
TOP VIEW
P
O
100
141
GIDMH 275/325
GIDMH 500/600
GIDMH 350/400 98
102
95
GIDMH 45/55
GIDMH 35/40
GIDMH 20/25
GIDMH 85/100
GIDMH 65/75
GIDMH 200/250
GIDMH 125/175
MODEL
72
80
90
87
A
67
70
77
84
216
196
176
86
76
71
36
36
36
151
171
131
42
32
32
48
30
35
G
72
72
62
55
156
132
110
110
47
55
47
B
62
78
90
C
66
60
42
54
36
32
30
30
38
38
42
D
30
30
30
71
71
111
91
H
23
39
51
32
30
20
20
30
24
18
18
18
20
18
I
18
18
18
K U
6204
184
167
67
57
52
140
140
140
21
20
-
-
14
14
18
18
M
147
123
101
101
47
41
35
23
53
69
81
L
19
23
19
60
80
140
100
40
N
40
40
12
6
6
6
8
4
9
11
9
O
12
12
12
P
12
12
12
10
12
10
T
4
6
6
18
16
14
2
2
4
4
4
3
3
3
3
V
12
12
12
10
8
8
10
W Z
201
117
141
161
181
47
75
63
95
95
X
33
44
29
33
29
67
62
57
51
77
Y
U
FILTERS FLEXCONN.
4TYP.
Z AHINGED DOORACCESS c/w
HANDLE (TYP.)
NOTES:
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT
UNITS UP TO 45/55 WILL HAVETURNED BASE RAILS TO ALLOW 1 PIECESHIPPING
SECTIONBLOWER/FILTER/COIL
SECTIONHEAT EXCHANGER
17 12
27 12 11 1
2
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
6 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION, MIX BOX AND DX COIL
TITLE
24NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
H
P
T
SUPPLY AIR
SUPPLY AIR
U
U
K
I
I
G
A
C
D
B
RETURN AIROPTION
RETURN AIROPTION
POWER BURNER
OPTION
PUFFDOOR
CONTROLPANEL
OPTION
COM
BUST
ION
PATH
FOUR PASSCOMBUSTION CHAMBER
V
FRESH AIRDAMPER
DRAINPAN
DXCOIL
3
M
FILTERS
Y
SPRING ISOLATOR
XL
Q
U
NMIN.
CLEARANCE
BLOWERS
W
OPTION
SIDE VIEW
SUPPLY AIR
TOP VIEW
FLOWFRESH AIR
41
M
47
35
23
23
19
19
67
57
52
72102GIDM 125/175
GIDM 200/250
GIDM 500/600
GIDM 350/400
GIDM 275/325
94 141
102
102
100
84
100
72
MODEL
GIDM 45/55
GIDM 35/40
GIDM 20/25
GIDM 85/100
GIDM 65/75
98
92
97
90
55
62
47
55
82
A B
47
9124309154100 32
80180
140
160
120
65
70
60
16836
36
36
36
131
148
111
4832
32
32
32
30
30
30
168
111
148
131
80
80
60
48
48
36
32
36
C
32
D
32
30
30
30
30
71
71
39
51
30
G
23
H
20
20
20
18
18
18
18
18
18
I
18
K
39
51
71
71
L
23
12412121590
15
20
16140
120
120
120
-
12
12
-
14
14
6
6
186
4
6
4
14
16
12
15
40
40
80
70
N
40
18
18
12
189
9
7
187
O P
12
12
12
10
10
T U
4
3
3
3
12
10
10
8
3
V
8
W
4585
71165
125
145
102
56
61
51
2
2
65
65
45
23
39
27
27
23
22
X
23
Y Z
44
41
44
41
39
29
29
29
27
27
Q
U
4TYP.
Z
O
RETURN AIRDAMPER
FLEXCONN.
MOTOR
HINGED DOORACCESS c/w
HANDLE (TYP)
AA
UNITS UP TO GIDMH 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECE SHIPPING
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT
NOTES:
U I
129
147
160
152
137
186
202
173
235
174
S
S
SECTIONMIX BOX
SECTIONBLOWER/FILTER/COIL
SECTIONHEAT EXCHANGER
17 12
11 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 25
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION, MIX BOX AND DX COIL
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
OPTIONSUPPLY AIR
NMIN.
CLEARANCE
I
I
U
U
K
G
A
C
D
B
FRESH AIRFLOW
SUPPLY AIR
RETURN AIROPTION
RETURN AIROPTION
POWER BURNER
SUPPLY AIROPTION
OPTION
PUFFDOOR
CONTROLPANEL
COM
BUST
ION
PATH
FOUR PASSCOMBUSTION CHAMBER
V
3
L
FRESH AIRDAMPER FILTERS
SPRING ISOLATOR
DRAINPAN
DXCOIL
M
Y
T
MOTOR
BLOWERS
X
Q
H
W
SIDE VIEW
TOP VIEW
O
P
UU
RETURN AIRDAMPER
FLEXCONN.
HINGED DOOR ACCESS c/w
HANDLE (TYP)
NOTES:
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT
UNITS UP TO GIDMH 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECESHIPPING
IU A A
S
SECTIONMIX BOX
SECTIONBLOWER/FILTER/COIL
SECTIONHEAT EXCHANGER
M
GIDMH 125/175
GIDMH 200/250
GIDMH 350/400
GIDMH 500/600
GIDMH 275/325
102 141
98
95
90
87
100
84
72
72
MODEL
GIDMH 65/75
GIDMH 85/100
GIDMH 20/25
GIDMH 35/40
GIDMH 45/55
4767
80
72
70
77
62
55
47
55
A B
86216
176
196
132
156
71
76
60
66
17136
36
36
32
36
131
151
91
111
4842
32
32
30
32
30
35
30
24
67204
167
184
123
147
57
52
47
41
3862
110
110
90
78
54
42
42
38
C D
2330
30
30
30
30
71
71
51
39
G H
1818
20
20
18
20
18
18
18
18
I K
1953
101
101
69
81
35
23
19
23
L
95
95
63
75
47
181
161
141
117
201
18
20
21140
100
140
140
140
-
6
6
6
-
14
14
6
12
186
4
6
4
4
16
14
12
12
O
9
11
9
12
18
40
80
60
40
40
N
12
12
12
4
8
P
10
12
12
10
12
T U
83
4
3
3
3
12
10
8
10
V W
77
67
62
57
51
2
2
29
44
33
29
33
X Y Z
44
41
44
39
41
29
29
27
29
27
Q
243
198
179
163
156
122
110
99
102
115
S
17 12
27 12 11 1
2
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
6 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND MIX BOX WITH RELIEF
TITLE
26NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
I
I
U
U
K
G
A
C
D
B
OPTIONRETURN AIR
SUPPLY AIR
RETURN AIROPTION
FRESH AIRFLOW
RELIEF AIRFLOW
POWER BURNER SUPPLY AIR
OPTION
CONTROLPANEL
PUFFDOOR
OPTION
COM
BUST
ION
PATH
FOUR PASSCOMBUSTION CHAMBER
U
V
3
L
RELIEF AIRDAMPER
M
FRESH AIRDAMPER
FILTERS
SPRING ISOLATOR
RETURN AIRDAMPER
M
T
P
NMIN.
CLEARANCE
M
Q
M U
H BLOWERS
W
UI
SUPPLY AIROPTION
SIDE VIEW
TOP VIEW
UU
4TYP.
Z
O
MOTOR
FLEXCONN.
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT.
HINGED DOORACCESS c/w
HANDLE
A A
SECTIONMIX BOX w/ RELIEF
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
V-BANK FILTER SECTION ALSO AVAILABLE, SEE PG. 29 FOR "A" DIMENSION
NOTES:
MODEL A B C D G H I K L M N O P Q T U V W
GIDM 20/25
GIDM 35/40
GIDM 45/55
GIDM 65/75
GIDM 85/100
GIDM 125/175
GIDM 200/250
GIDM 275/325
GIDM 350/400
GIDM 500/600
52
60
67
62
68
75
80
87
92
107 141
100
55
84
72
72
62
55
47
47
180
160
80
140
120
100
80
48
60
32
36
48
32
36
32
30
30
30
30
30
71
71
39
51
23
20
20
18
20
18
54
60
65
70
80
32
36
36
36
36
91
111
131
148
168
30
32
32
32
32 48
30
30
30
24
18
18
18
18
18
168
71
148
131
111
91
23
51
39
71
67
35
57
52
47
41
23
23
19
19
140
80
120
120
90
120
40
70
40
40
16
15
20
15
15
9
9
7
7
-
12
12
12
12
-
18
18
18
18
151
93
117
105
137
127
60
60
69
69
14
14
12
12
12
12
10
10
6
6 6
6
4
4
4
4
3
3
3
3 8
8
10
10
12
12
12
14
16
18
Z
2
2
17 12
11 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 27
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND MIX BOX WITH RELIEF
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
OPTIONSUPPLY AIR
NMIN.
CLEARANCE
I
I
U
U
K
G
A
C
D
B
OPTIONRETURN AIR
SUPPLY AIR
RETURN AIROPTION
FLOWRELIEF AIR FRESH AIR
FLOW
POWER BURNER SUPPLY AIR
OPTION
PUFFDOOR
CONTROLPANEL
OPTION
COM
BUST
ION
PATH
FOUR PASSCOMBUSTION CHAMBER
V
3
L
RELIEF AIRDAMPER
FILTERS
SPRING ISOLATOR
RETURN AIRDAMPER
M
FRESH AIRDAMPER
M T
MOTOR
BLOWERS
Q
MU UM
H
W
I U
SIDE VIEW
TOP VIEW
P
O
UU
4TYP.
Z HINGED DOORACCESS c/wHANDLE
FLEXCONN.
A SIZES 65/75 AND UP SPLIT FOR SHIPMENT.
SECTIONMIX BOX w/ RELIEF
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
V-BANK FILTER SECTION ALSO AVAILABLE, SEE PG. 30 FOR "A" DIMENSION
NOTES:
GIDMH 350/400
GIDMH 500/600
68
77
100
141
GIDMH 20/25
GIDMH 35/40
GIDMH 45/55
GIDMH 65/75
GIDMH 85/100
GIDMH 125/175
GIDMH 200/250
GIDMH 275/325
MODEL
5542
65
60
50
57
84
72
62
72
40
47
37
A
47
55
47
B
151
171
76
86216
196 36
36
32
42
30
48
184
204
111
131
D
42
54
38
42
38
60
66
71
110
156
176
132
110
78
90
62
C
30
32
36
36
30
30
30
30
G
2071
71
91
32
32
20
30
39
51
23
H
18
20
18
I
10118
35
30
18
24
167
147
101
123
18
18
18
K
69
81
53
L
140
14067
57
21 -
-
157
137
14
14
6
4
6
6
6
12
12
8
12
140
140
100
N
6023
52
47
35
41
80
19
23
19
M
40
40
40
12
18
18
O
11
9
9
69
117
127
93
105
P
60
69
60
Q
12
12
12
10
12
10
T U
6
6
16
18 2
2
103
4
4
4
4 12
14
12
12
3
3
V
3
10
8
W
8
Z
20
AA
17 12
27 12 11 1
2
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
6 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND MIX BOX WITHRELIEF AND RETURN AIR BLOWER SECTION
TITLE
28NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
I
T
OPTIONSUPPLY AIR
SUPPLY AIROPTION
I
I
PUFFDOOR
B
C
G
A
D
MOTOR
RETURN AIROPTION
OPTIONRETURN AIR
SIDE VIEW
RELIEF AIRFLOW
FRESH AIRFLOW
POWER BURNER
CONTROLPANEL
TOP VIEW
COM
BUST
ION
PATH
FOUR PASSCOMBUSTION CHAMBER
R
V
M
L
MU
FRESH AIRDAMPER
SPRING ISOLATOR
RETURN AIRDAMPER
RELIEF AIRDAMPER
M
SPRING ISOLATOR
FILTERS
UM
Q
BLOWER
U M
NMIN.
CLEARANCE
BLOWERS
U
U
K SUPPLY AIROPTION
P
H
U
U
WAAA
U
O
3
FLEXCONN.
MOTOR
HINGED DOORACCESS c/w
HANDLE (TYP)
4TYP.
Z
SECTIONRETURN AIR BLOWER
SECTIONMIX BOX w/ RELIEF
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
V-BANK FILTER SECTION ALSO AVAILABLE, SEE PG. 29 FOR "A" DIMENSION
A SPLIT FOR SHIPMENTNOTES:
7280GIDM 200/250
GIDM 500/600
GIDM 350/400
GIDM 275/325
92
107
87
100
141
84
GIDM 125/175
GIDM 85/100
GIDM 65/75
GIDM 45/55
GIDM 35/40
GIDM 20/25
MODEL
68
75
62
67
62
72
55
55
60
52
A
47
47
B
11130321113660120
168
148
131
80
70
65140
160
180 36
36
36
32
32
32
30
48
30
148
168
131
54
32
36
32
48
36
D
100
80
80
60
48
32
C
32
30
30
30
30
30
G
71
91
71
51
20
30
20
20
39
23
H
18
18
I
18
24
18
18
71
91
71
51
18
18
K
39
23
L
11712
12
1512047
120
120
140
57
67
52
20
16 -
- 137
157 14
14
6
6
18
18
18
18
12
12
90
N
35
41
23
23
80
70
40
19
19
M
40
40
9
9
15
15
7
7
O
93
105
69
69
P
60
60
Q
12
12
12
12
10
10
T U
124
6
4
6
18
16
14
2
2
4
4
3
3
12
12
10
10
3
3
V
8
8
W Z
109
137
127
127 122
117
75
100
68
72
R
61
17 12
11 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 29
GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION, MIX BOX WITH RELIEFAND RETURN AIR BLOWER SECTION
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
I
T
OPTIONSUPPLY AIR
SUPPLY AIROPTION
I
I
BA
C
D
RETURN AIROPTION
OPTIONRETURN AIR
TOP VIEW
FRESH AIRFLOW
SIDE VIEW
RELIEF AIRFLOW
POWER BURNER
PUFFDOOR
CONTROLPANEL
BLOWERS
COM
BUST
ION
PATH
FOUR PASSCOMBUSTION CHAMBER
R
M
V
M
3
L
U
FILTERS
RETURN AIRDAMPER
SPRINGISOLATOR
RELIEF AIRDAMPER
M
FRESH AIRDAMPER
SPRING ISOLATOR
M
Q
U M
BLOWERS
MOTOR
U
U
U
K
G
SUPPLY AIROPTION
H
NMIN.
CLEARANCE
U
P
141
100
7260GIDMH 200/250
GIDMH 275/325
GIDMH 500/600
GIDMH 350/400 68
77
65 84
GIDMH 125/175
GIDMH 85/100
GIDMH 65/75
GIDMH 45/55
GIDMH 35/40
GIDMH 20/25
MODEL
5547
50
57
42
62
72
55
40
37
A
47
47
B
147303236156 66 111
71
86
76
176
196
216
36
36
36
151
171
131
32
42
32
30
48
35
184
204
167
60
38
42
38
54
42
90
110
132
110
C
62
78
30
30
32
30
D
30
30
G
2051
71
91
71
20
30
20
39
23
H
18
18
I
8118
18
24
18
101
123
101
18
18
K
69
53
L
11747 140 6
6140
140
14057
67
52 20
21
-
-
137
151 14
14
6
40
40
40
80
60
N
100
23
35
41
23
M
19
19
11
18
18
12
9
9
O
6912
4
6
8
93
105
69
12
12
P
60
60
Q
12
12
12
12
10
10
T U
124
6
4
6
18
14
16
2
2
103
4
4
3
12
12
10
3
3
V
8
8
W Z
137
127
122127
117
109
100
75
72
68
61
R
U
W
U
O
FLEXCONN.
HINGED DOORACCESS c/w
HANDLE (TYP)
MOTOR
4TYP.Z
A SPLIT FOR SHIPMENT
SECTIONRETURN AIR BLOWER
SECTIONMIX BOX w/ RELIEF
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
NOTES:
V-BANK FILTER SECTION ALSO AVAILABLE, SEE PG. 30 FOR "A" DIMENSION
A A A
17 12
27 12 11 1
2
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
6 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOORUNIT GRAVITY VENTED WITH FLAT FILTER SECTION
TITLE
30NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
H
C
FLOW
FRES
H AI
R
E
SUPP
LY A
IROP
TION
F
PUFF
DOOR
T
L
MD
SPRI
NG
ISOL
ATOR
SIDE
VIE
W
FRES
H AI
RDA
MPE
R
C L
3
4
END
VIEW
BLO
WER
S
POW
ERBU
RNER
GRAV
ITY
VENT
CONN
ECTI
ON
N M
IN.
CLEA
RANC
E
GAS
CONN
ECTI
ON
K
A
CONT
ROL
PANE
L
SUPP
LY A
IROP
TION
COM
BUST
ION
PATH
W
A
K
B
U
GIDM
500
/600
GIDM
350
/400
GIDM
275
/325
GIDM
200
/250
GIDM
125
/175
GIDM
85/
100
GIDM
45/
55
GIDM
65/
75
GIDM
35/
40
GIDM
20/
25
140
9630
6584
67 8272
141
100
180
160
8070
117
107
4830
6250 6256
7272
38 3834
55 5547
3447
8048
120
100
6054
60 8048
36 3632
1882 9590
3024
70 7064
18 1818
3232
6418
3252
6512
013
1
1620
168
148
3232
8070
6757
140
120
7115 1515
111
91
9 97
51 7139
20 323020 2018
723
18
3548 6054
4741
36 3632
23 2319
80 120
9040 7040
3219
40
4
66
66
22
4 443 333
1410 1212 1210 14
16 18148 12 12128 1010V
U
H
CZ
G
FILT
ERS
U
HING
ED D
OOR
ACCE
SS c
/wHA
NDLE
HEAT
EXC
HANG
ERSE
CTIO
N
FILT
ER/B
LOW
ERSE
CTIO
N
A S
IZES
65/
75 A
ND U
P SP
LIT
FOR
SHIP
MEN
T
-10 10101015 1015 --
P
MOT
OR
MOD
EL
AB
CD
EF
GH
KL
MN
UV
ZT
WP
171 2
13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2
13 8 13 8 13 8 19 16 19 16 19 16 19 16
121 2
121 2
111 2
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 31
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOORUNIT GRAVITY VENTED WITH ANGULAR FILTER SECTION
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
H
C
FLOW
FRES
H AI
R
E
SUPP
LY A
IROP
TION
F
PUFF
DOOR
T
L
MD
SPRI
NG
ISOL
ATOR
SIDE
VIE
W
FRES
H AI
RDA
MPE
R
3
4
END
VIEW
BLO
WER
S
POW
ERBU
RNER
GRAV
ITY
VENT
CONN
ECTI
ON
N M
IN.
CLEA
RANC
E
GAS
CONN
ECTI
ON
K
A
CONT
ROL
PANE
L
SUPP
LY A
IROP
TION
COM
BUST
ION
PATH
W
A
K
B
U
V
U
HC
Z
G
FILT
ERS
U
HING
ED D
OOR
ACCE
SS c
/wHA
NDLE
HEAT
EXC
HANG
ERSE
CTIO
N
FILT
ER/B
LOW
ERSE
CTIO
N
A S
IZES
65/
75 A
ND U
P SP
LIT
FOR
SHIP
MEN
T
P
GIDM
500
/600
GIDM
350
/400
GIDM
275
/325
GIDM
200
/250
GIDM
125
/175
GIDM
85/
100
GIDM
45/
55
GIDM
65/
75
MOD
EL
GIDM
35/
40
GIDM
20/
25
140
9630
6584
67 827214
110
018
016
08070
117
107
4830
6250 6256
7272
38 383455 5547
A 34
B 47
8048
120
100
6054
60 804836 3632
1882 9590
3024
70 706418 1818
C 32
D 32
E 64
F 18
3252
6512
013
1
162016
814
83232
80706757
140
120
7115 1515
111
91
9 9751 7139
20 323020 2018
G 7
H 23
K 18
3548 6054
4741
36 363223 2319
80 120
9040 7040
L 32
M 19
N 40
4
6666
22
4 443 33
UV 3
Z
1410 1212 1210T 1416 18148 12 12128 1010W
- --10 101010101515P
171 2
13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2
13 8 13 8 13 8 19 16 19 16 19 16 19 16
121 2
121 2
111 2
C L
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOORUNIT GRAVITY VENTED WITH V-BANK FILTER SECTION
TITLE
32NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
H
C
FLOW
FRES
H AI
R
E
SUPP
LY A
IROP
TION
F
PUFF
DOOR
T
L
MD
SPRI
NG
ISOL
ATOR
SIDE
VIE
W
FRES
H AI
RDA
MPE
R
C L
FILT
ERS
3
4
END
VIEW
BLO
WER
S
POW
ERBU
RNER
GRAV
ITY
VENT
CONN
ECTI
ON
N M
IN.
CLEA
RANC
E
GAS
CONN
ECTI
ON
K
A
CONT
ROL
PANE
L
SUPP
LY A
IROP
TION
G
COM
BUST
ION
PATH
W
A
K
B
U
U
U
Z
C
HU
HING
ED D
OOR
ACCE
SS c
/wHA
NDLE
FILT
ER/B
LOW
ERSE
CTIO
N
SECT
ION
HEAT
EXC
HANG
ER
A S
IZES
65/
75 A
ND U
P SP
LIT
FOR
SHIP
MEN
T
GIDM
20/
25
GIDM
35/
40
MOD
EL
GIDM
65/
75GI
DM 4
5/55
GIDM
85/
100
GIDM
125
/175
GIDM
200
/250
GIDM
275
/325
GIDM
350
/400
GIDM
500
/600
6784
6530
9614
0
160
180
72 82
100
141
107
117
8070
4830
100
120
4734 3838 56 6250
62 727255 55
34AB 47
1864
3248
4880
6054
60 8036 36
8218
95903024
70 7018 18
C 32
D 32
E 64
F 18
1413
112
065
5232
57 67
148
168
162070 80
3232
14
120
140
66
19 19 2323 41 4735
3218
397 15
71 111
151591
9 951 71
4820
54 603230
363620 20
G 7
H 2332
K 18
L
1040
1212 12
80 90 120
7040
1040
MN
TU
144
22
1816
66
83
124
121244
10 103 3V 3
WZ
8
- --15 10 10101010P 15
P
171 2
13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2
13 8 13 8 13 8 19 16 19 16 19 16 19 16
121 2
121 2
111 2
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 33
GIDM SERIES VERTICAL CONFIGURATION UPFLOWINDOOR UNIT GRAVITY VENTED WITH FLAT FILTERSECTION AND MIX BOX
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
COM
BUST
ION
PATH
END
VIEW
H
C BLO
WER
S
RETU
RN A
IRFL
OW
FRES
H AI
RFL
OW
E
T
M
D
KU
Q
RETU
RN A
IRDA
MPE
R
SIDE
VIE
W
FRES
H AI
RDA
MPE
R
3
4
POW
ERBU
RNER
GRAV
ITY
VENT
CONN
ECTI
ON
N M
IN.
CLEA
RANC
E
PUFF
DOOR
K
A
A
PANE
LCO
NTRO
L
GL F
SUPP
LY A
IROP
TION
SUPP
LY A
IROP
TION
GAS
CONN
ECTI
ON
W
A
SPRI
NG
ISOL
ATOR
K
B
U
FILT
ERS
GIDM
500
/600
GIDM
350
/400
GIDM
275
/325
GIDM
200
/250
GIDM
125
/175
GIDM
85/
100
GIDM
45/
55GI
DM 6
5/75
GIDM
35/
40
GIDM
20/
25
MOD
EL
15 1515 20 16
140
137
3065
8467
180
160
8272
141
100
151
161
70 80
30 48
120
100
8080604832
50 625638 3834
62 72 7247 5555
A 3447B
C
9991 111
136
129
9948 60543632 36
18 30241818 189 97
9132D
E
18FG 7
3252
6541
120
131
148
168
3232
8070
140
120
6757
4457
71 111
915139 7148
20 3230
6054
20 2018
36 3632
23HK 18
L 32
120
908035 474123 2319
40 7040
29 413929 2927
M 19
N 40
Q 27
4
66
66
22
4 443 33
TU
V 3
Z
14121210 1210 14
14 181612 121210108W 8
V
C
HU
U
Z
HING
ED D
OOR
ACCE
SS c
/wHA
NDLE
SECT
ION
FILT
ER/B
LOW
ER
SECT
ION
HEAT
EXC
HANG
ER
A S
IZES
65/
75 A
ND U
P SP
LIT
FOR
SHIP
MEN
T
- - -10 10 1015 101015P
P
C L
171 2
13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2
13 8 13 8 13 8 19 16 19 16 19 16 19 16
121 2
121 2
111 2
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOORUNIT GRAVITY VENTED WITH ANGULAR FILTER SECTIONAND MIX BOX
TITLE
34NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
C L
COM
BUST
ION
PATH
END
VIEW
H
C BLO
WER
S
RETU
RN A
IRFL
OW
FRES
H AI
RFL
OW
E
T
M
D
KU
Q
RETU
RN A
IRDA
MPE
R
SIDE
VIE
W
FRES
H AI
RDA
MPE
R
3
4
POW
ERBU
RNER
GRAV
ITY
VENT
CONN
ECTI
ON
N M
IN.
CLEA
RANC
E
PUFF
DOOR
K
A
A
PANE
LCO
NTRO
L
GL F
SUPP
LY A
IROP
TION
SUPP
LY A
IROP
TION
GAS
CONN
ECTI
ON
W
A
SPRI
NG
ISOL
ATOR
K
B
U
FILT
ERS
GIDM
500
/600
GIDM
350
/400
GIDM
275
/325
GIDM
200
/250
GIDM
125
/175
GIDM
85/
100
GIDM
45/
55GI
DM 6
5/75
GIDM
35/
40
GIDM
20/
25
MOD
EL
15 1515 20 16
140
137
3065
8467
180
160
8272
141
100
151
161
70 80
30 48
120
100
8080604832
50 625638 3834
62 72 7247 5555
A 3447B
C
9991 111
136
129
99
48 60543632 36
18 30241818 189 97
9132D
E
18FG 7
3252
6541
120
131
148
168
3232
8070
140
120
6757
4457
71 111
915139 71
4820 3230
6054
20 2018
36 3632
23HK 18
L 32
120
908035 474123 2319
40 7040
29 413929 2927
M 19
N 40
Q 27
4
66
66
22
4 443 33
TU
V 3
Z
14121210 1210 14
14 181612 121210108W 8
V
C
HU
U
Z
HING
ED D
OOR
ACCE
SS c
/wHA
NDLE
SECT
ION
FILT
ER/B
LOW
ER
SECT
ION
HEAT
EXC
HANG
ER
A S
IZES
65/
75 A
ND U
P SP
LIT
FOR
SHIP
MEN
T
P
- - -10 10 1015 101015P
171 2
13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2
13 8 13 8 13 8 19 16 19 16 19 16 19 16
121 2
121 2
111 2
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 35
GIDM SERIES VERTICAL CONFIGURATION UPFLOWINDOOR UNIT GRAVITY VENTED WITH V-BANK FILTERSECTION AND MIX BOX
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
COM
BUST
ION
PATH
END
VIEW
H
C BLO
WER
S
RETU
RN A
IRFL
OW
FRES
H AI
RFL
OW
E
T
M
D
KU
Q
RETU
RN A
IRDA
MPE
R
SIDE
VIE
W
FRES
H AI
RDA
MPE
R
3
FILT
ERS
4
POW
ERBU
RNER
GRAV
ITY
VENT
CONN
ECTI
ON
N M
IN.
CLEA
RANC
E
PUFF
DOOR
K
PANE
LCO
NTRO
L
GL F
SUPP
LY A
IROP
TION
SUPP
LY A
IROP
TION
GAS
CONN
ECTI
ON
W
A
SPRI
NG
ISOL
ATOR
K
B
U
U 6 6
MOD
EL
GIDM
20/
25
GIDM
35/
40
GIDM
65/
75GI
DM 4
5/55
GIDM
85/
100
GIDM
125
/175
GIDM
200
/250
GIDM
275
/325
GIDM
350
/400
GIDM
500
/600
7G 7 99 162015 1515
6784
6530
137
140
160
180
72 82
100
141
161
151
8070
4830
C 32 48 60 80 80 100
120
34 3838 56 625062 727255 5547
34AB 47
99 129
136
111
91 99
48 54 603632 36
18 24 301818 18
E 91
D 32
F 18
1413
112
041
6552
32
57 67
32 3216
8
148
70 80
57 44
120
140
14
19M 19 2323 41 4735
18 2020 30 322071 91 11
1
7139 51
48 54 6032 3636
18KH 23
32L
27 2929 39 412980 90 12
0
40 7040
121210 12
27Q
40N
10T
144
16 18
6 622
8 10 10 12 12124 4 43 33
8W
3VZ
V
U
HING
ED D
OOR
ACCE
SS c
/wHA
NDLE
(TYP
)
Z
A
C
HU
FILT
ER/B
LOW
ERSE
CTIO
N
SECT
ION
HEAT
EXC
HANG
ER
SECT
ION
MIX
BOX
A S
IZES
65/
75 A
ND U
P SP
LIT
FOR
SHIP
MEN
T
- --15 10 1015 101010P
A
P
C L
171 2
13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2
13 8 13 8 13 8 19 16 19 16 19 16 19 16
121 2
121 2
111 2
GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNITGRAVITY VENTED WITH FLAT FILTER SECTION AND DX COIL
TITLE
36NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
COM
BUST
ION
PATH
END
VIEW
H
C
FRES
H AI
RFL
OW
T
K
L
Y
MD
DX C
OIL
(X x
Y)
DRAI
NPA
NSP
RING
IS
OLAT
OR
SIDE
VIE
W
FRES
H AI
RDA
MPE
R
FILT
ERS
3
4
BLO
WER
S
POW
ERBU
RNER
GRAV
ITY
VENT
CONN
ECTI
ON
N M
IN.
CLEA
RANC
E
GAS
CONN
ECTI
ON
PUFF
DOOR
A
PANE
LCO
NTRO
L
F
SUPP
LY A
IROP
TION
SUPP
LY A
IROP
TION
W
A
K
B
U
GIDM
20/
25
GIDM
35/
40
MOD
EL
GIDM
65/
75GI
DM 4
5/55
GIDM
85/
100
GIDM
125
/175
GIDM
200
/250
GIDM
275
/325
GIDM
350
/400
GIDM
500
/600
6784
6530
102
140
160
180
72 8210
014
112
213
78070
4830
100
120
4734 3838 56 6250
62 727255 55
34AB 47
1890
3248
4880
6054
60 8036 36
9818
102
102
3024
97 9218 18
C 32
D 32
E 82
F 18
1413
112
065
5232
57 6714
816
81620
70 803232
1412
014
066
19 19 2323 41 4735
3218
397 15
71 111
151591
9 951 71
4820
54 603230
363620 20
G 7
H 2332
K 18
L
1040
1212 12
80 90 120
7040
1040
MN
TU
144
221816
66
83
124
121244
10 103 3
ZV 3
W 8
125
165
145
65 105
8545 6533X 17
56 716139 514527 2723Y 23V
U
C
HU
FILT
ER/B
LOW
ER/C
OIL
SECT
ION
HEAT
EXC
HANG
ERSE
CTIO
N
HING
ED D
OOR
ACCE
SS c
/wHA
NDLE
E
Z
A S
IZES
65/
75 A
ND U
P SP
LIT
FOR
SHIP
MEN
T
G
- --10 101010 1015P 15
P
C L
171 2
13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2
13 8 13 8 13 8 19 16 19 16 19 16 19 16
121 2
121 2
111 2
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 37
GIDM SERIES VERTICAL CONFIGURATION UPFLOWINDOOR UNIT GRAVITY VENTED WITH FLAT FILTERSECTION, DX COIL AND MIX BOX
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
C L
DFR
ESH
AIR
FLOW
SPRI
NG
ISOL
ATOR
3 M
FILT
ERS
FRES
H AI
RDA
MPE
R
BLO
WER
S
C
H
END
VIEW
COM
BUST
ION
PATH
B
K
U
GAS
CONN
ECTI
ON
N M
IN.
CLEA
RANC
E
GRAV
ITY
VENT
CONN
ECTI
ON
W
POW
ERBU
RNER
SUPP
LY A
IROP
TION
SIDE
VIE
W
L
T
K
CONT
ROL
PANE
L
PUFF
DOOR
GF
SUPP
LY A
IROP
TION
E
A
4
Y
DX C
OIL
(X x
Y)
DRAI
NPA
NQK
U
RETU
RN A
IRFL
OWR/A
DAM
PER
U 6 6
MOD
EL
GIDM
20/
25
GIDM
35/
40
GIDM
65/
75GI
DM 4
5/55
GIDM
85/
100
GIDM
125
/175
GIDM
200
/250
GIDM
275
/325
GIDM
350
/400
GIDM
500
/600
7G 7 99 162015 1515
6784
6530
143
140
160
180
72 8210
014
118
116
68070
4830
C 32 48 60 80 80 100
120
34 3838 56 625062 727255 5547
34AB 47
121
141
143
127
117
126
48 54 603632 36
18 24 301818 18
E 109
D 32
F 18
1413
112
041
6552
32
57 6732 32
168
148
70 8057 44
120
140
14
19M 19 2323 41 4735
18 2020 30 322071 91 11
1
7139 51
48 54 6032 3636
18KH 23
32L
27 2929 39 412980 90 12
0
40 7040
121210 12
27Q
40N
10T
144
16 186 6
22
8 10 10 12 12124 4 43 33
8W
3VZ
125
165
145
65 105
8565453317XY 39 452723 2723 56 716151
V
U
C
HU
Z
FILT
ER/C
OIL/
BLOW
ERSE
CTIO
N
HEAT
EXC
HANG
ERSE
CTIO
N
MIX
BOX
SECT
ION
HING
ED D
OOR
ACCE
SS c
/wHA
NDLE
(TYP
)
AA
SIZ
ES 6
5/75
AND
UP
SPLI
T SH
IPM
ENT
- --10 10101015 1015P
A
P
171 2
13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2
13 8 13 8 13 8 19 16 19 16 19 16 19 16
121 2
121 2
111 2
GIDM SERIES HORIZONTAL CONFIG. OUTDOOR UNITGRAVITY VENTED c/w FLAT FILTER SECTION AND MIXBOX WITH RELIEF AND RETURN AIR BLOWER SECTION
TITLE
38NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AND TO MANUFACTURING TOLERANCES
SIDE VIEW
TOP VIEW
GRAVITY VENT CAP
U
H
P
U
K
G
I
A
C
D
B
RETURN AIROPTION
RETURN AIROPTION
SUPPLY AIR
POWERBURNER
SUPPLY AIROPTION
OPTION
CONTROLPANEL
MOTOR
FRESH AIRFLOW
RELIEF AIRFLOW
COM
BUST
ION
PATH
FOUR PASSCOMBUSTION
CHAMBERM
R
V
3
M
L
U
SPRING ISOLATOR
4
Y
BLOWERS
FILTERS
J(X
x Y)
RETURN AI
R DAM
PER
XUINLETHOOD
FRESH AIRDAMPER
Q
BLOWER
RELIEF AIRDAMPER
NMIN.
CLEARANCE
I
OPTIONSUPPLY AIR
O
M
19
1923
23
41
35
52
67
57
47
7275GIDM 125/175
GIDM 275/325
GIDM 350/400
GIDM 500/600
GIDM 200/250
107
92
80
87
141
100
84
72
A SPLIT FOR SHIPMENT
MODEL
GIDM 20/25
GIDM 35/40GIDM 45/55
GIDM 65/75GIDM 85/100 68
62
6760
6255
4755
52
A
47
B
9153309132100 54
180
160
140
120
70
80
65
60
36
36
36
36
148
168
131
111
64
59
69
7932
32
32
32 131
168
148
111
8080
4860
4836
3236
C
32 32
D
3030
3030
7171
5139
30
G
23
H
28
2831
3931
2020
2018
18
I J
3951
7171
L
23
109 12691590 12
16
15
140
120
120
120
20
-
-
12
12
102
90
73
79
127
122
137
117
14
14
6
6
15
4040
7080
40
N
9
97
1218
1818
7
O
18
P
5159
4539
10075
6872
29
Q
61
R
1212
1012
10
T U
124
6
6
4
4
16
18
14
12
2
2
43
33
1210
810
V
3
W
8
Z
70
90
78
64
60
4250
20
3630
X
57
72
62
46
52
2840
24
2824
Y
U
30
48
30
24
30
1818
18
1818
K
U
XUJ
RELIEFHOOD
4TYP.
Z
MOTOR
FLEXCONN.
HINGED DOORACCESS c/w
HANDLE (TYP)
DRAIN PAN PROVIDEDIN W.H. AREA c/w
DRAIN HOLE IN BTM.
A
A A
SECTIONRETURN AIR BLOWER MIX BOX w/ RELIEF
SECTIONBLOWER/FILTER
SECTIONHEAT EXCHANGER
SECTION
FOR DIMENSIONS OF OTHER COMPONENTS (i.e. V-BANK FILTER SECTION)
NOTES:
SEE INDOOR UNIT DRAWINGS
17 12
11 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
TITLE
NOTEINDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD. 39
GIDMH SERIES HORIZONTAL CONFIG. OUTDOOR UNITGRAVITY VENTED c/w FLAT FILTER SECTION, MIX BOXWITH RELIEF AND RETURN AIR BLOWER SECTION
ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES
TOP VIEW
SIDE VIEW
GRAVITY VENT CAP
U
H
SUPPLY AIR
U
K
NMIN.
CLEARANCE
G
4TYP
D
C
I
A B
RETURN AIROPTION
RETURN AIROPTION
OPTION
FRESH AIRFLOW
POWER BURNER
OPTION
CONTROLPANEL
FLOWRELIEF AIR
COM
BUST
ION
PATH
SUPPLY AIR
FOUR PASSCOMBUSTION
CHAMBER
R
V
M
3
L
U M
JU
SPRINGISOLATOR
FILTERS
4
MOTORY
SPRINGISOLATOR
Q
RETU
RN A
IR D
AMPE
R
X
AA A
FRESH AIRDAMPER
(X x
Y)
RELIEF AIRDAMPER
MOTOR
BLOWERS
I
OPTIONSUPPLY AIR
P
19
19
M
23
41
35
23
52
67
57
47
GIDMH 125/175
GIDMH 350/400
GIDMH 500/600
GIDMH 275/325
GIDMH 200/250
77 141
65
68
57
60
84
100
72
72
MODEL
GIDMH 20/25
GIDMH 35/40
GIDMH 45/55
GIDMH 65/75
GIDMH 85/100
42
50
40
47
55
62
47
55
A
37
B
47
216 86
176
196
132
156
71
76
60
66
17136
36
36
36
32
131
151
111
91 24
35
48
30
30
42
32
32
32
30
204
123
167
184
147
110
110
78
90
42
54
38
42
62
C
38
D
30
30
30
30
71
71
51
39
G
30
H
23
18
18
18
18
18
20
20
20
18
18
K
69
101
101
81
L
53
91
18
21
20
140
100
140
140
140
-
-
6
6
6
127102
73
79
69
127
122
117
113
614
14
12
12
18
11
60
80
40
40
40
N
12
12
9
4
8
12
O
9
P
51
59
45
39
101
83
82
69
Q
29
R
69
12
12
12
10
T
10
U
4
186
12
16
14
12
4
6
4
2
2
10
12
10
4
3
3
3 8
V
3
W
8
ZI
79
39
69
64
53
59
31
31
28
28
J X
78
46
68
63
52
58
50
36
30
20
78
46
68
63
58
52
36
34
30
30
Y
U
O
Z
BLOWERS
XU
FLEXCONN.
J
DRAIN PAN PROVIDEDIN W.H. AREA c/w
DRAIN HOLE IN BTM.
HINGED DOORACCESS c/w
HANDLE (TYP)
RELIEFHOOD
INLETHOOD
A SPLIT FOR SHIPMENT
MIX BOX w/ RELIEFSECTIONSECTION
RETURN AIR BLOWERSECTION
FILTER/BLOWER HEAT EXCHANGERSECTION
FOR DIMENSIONS OF OTHER COMPONENTS (i.e. V-BANK FILTER SECTION) SEE INDOOR UNIT DRAWINGS
NOTES:
17 12
27 12 11 1
2
4 12
4 12
4 12
4 12
4 12
4 12
4 12
4 12
6 12
12 12
1 38
1 38
1 38
1 38
1 916
1 916
1 916
1 916
GIDM/GIDMH MODULATING MANIFOLD ARRANGEMENTFOR CGA, ETL, F.M., AND I.R.I. APPROVAL
TITLE
40
LEGEND
1
REF.
3
4
5
6
8
9
2
DESCRIPTION
UNION CONNECTION
PILOT MANUAL SHUT-OFF VALVE
PILOT PRESSURE REGULATOR
PILOT AUTOMATIC SAFETY SHUT-OFF VALVE
PILOT MANUAL FIRING VALVE
MAIN BURNER GAS PRESSURE REGULATOR
MAIN BURNER TEST FIRING VALVE
MAIN BURNER ORIFICE
1/8" TEST PORT
7 MAIN BURNER AUTO SAFETY SHUT-OFF VALVE
10
11
MODULATING GAS VALVE
CGA APPROVED GAS MANIFOLD
ETL APPROVED GAS MANIFOLD
I.R.I. APPROVED GAS MANIFOLD
F.M. APPROVED GAS MANIFOLD
LOW GAS PRESSURE SWITCH
HIGH GAS PRESSURE SWITCH
AUXILLARY SAFETY SHUT OFF VALVE
NORMALLY OPEN VENT VALVE
VENT LIMITER
MAIN MANUAL VALVE
17
16
14
15
13
12
NOTE(S):1. ON MANIFOLD SIZES 1 1/4" ON UP ITEM 6 MUST BE VENTED TO THE ATMOSPHERE
3. ON MANIFOLD SIZES 1 1/4" ON UP ITEM 6 MUST BE VENTED TO THE ATMOSPHERE2. ITEM 15 ON UNITS ABOVE 400,000 BTU ONLY (MOTORIZED)1. ITEM 13 AND 14 ON UNITS OVER 2,475,000 BTU ONLY.
NOTE(S):
1. ON MANIFOLD SIZES 1 1/4" ON UP ITEM 6 MUST BE VENTED TO THE ATMOSPHERENOTE(S):
1. ON MANIFOLD SIZES 1 1/4" ON UP ITEM 6 MUST BE VENTED TO THE ATMOSPHERENOTE(S):
2. ITEMS 13 AND 14 ABOVE 400,000 BTU ONLY3. ITEM 16 ABOVE 1,000,000 BTU ONLY
Type and Description
Furnish an I.C.E GIDM Model indirect fired self-contained make-up air unit in accordance with the following specifications. The unit shall be ETL andC.G.A certified
The heater shall be designed to ensure a minimum efficiency of 80% at full firing rate. The heat exchanger and blower shall be constructed so they caneasily be disassembled and reassembled in the field if necessary. The unit shall be equipped to operate from a single point power connection. Theheater shall be flame tested before shipment and a detailed flame test report shall be kept on file by the manufacturer. Factory testing shall be confirmedwith a combustion analyzer and flow meter. The heater shall be shipped completely factory assembled and wired including all prepiped manifoldcomponents and fuses, ready for immediate power and fuel connections.
Casing
The unit exterior casing shall be heavy gauge G90 rated bonderized steel. Unit roofs shall be sloped for water drain off and feature standing seamconstruction. The entire unit casing shall be insulated with 2 in. thick 3-lb. Fiberglass insulation with hard neoprene backing in a sandwich wall fashion.The unit exterior shall be finished with industrial catalyzed epoxy paint. An integral welded iron channel frame shall support the unit casing. Formedsheet metal bases are unacceptable. The structural iron frame shall be sandblasted, primed and finished with industrial catalyzed epoxy paint.
Blower/Motor Section
The fan section and motor assembly shall be constructed in accordance with the requirements of the Air Moving and Conditioning Association (AMCA).The assembly shall be designed to house the fan(s), bearings, motor, and v-belts which shall be selected for at least 50% above the rated motorcapacity. The fan(s) and motor shall be mounted on a welded unitary base made of angle iron frame. The frame shall be sandblasted, primed andfinished with industrial catalyzed epoxy paint. The unitary base shall be provided with seismic spring vibration isolation. The blower section shall have ahinged access door to allow easy maintenance of filters and belts. The NEMA T-Frame motor shall be mounted on an adjustable base located within thefan section. The blower wheel shall be statically and dynamically balanced, and mounted on a turned, ground and polished shaft with rigid bearingsupports. The shaft shall be designed with a maximum operating speed not exceeding 75% of the first critical speed. The bearings shall be split taperlock ball bearing type L20 minimum life of 100,000 hours.
Heat Exchanger
The heat exchanger shall be of four pass design with a primary combustion chamber and multi-tube secondary. Internal turbulators or other fluerestrictor to boost efficiency are unacceptable. The entire primary heat transfer surface shall be constructed of Type 409 Series stainless steel, and shallbe cooled in its entirety by the air to be heated. The Secondary heat transfer surface shall also be constructed from Type 409 Series stainless steel. The stainless steel tubes shall be continuously welded into the secondary front and rear header tube sheets to ensure an airtight seal. Mechanicallyswedging the tubes are unacceptable. All heat transfer surfaces, including headers and the front collector box, shall be inside the casing and in theairstream. The construction of the heat exchanger shall permit free, unrestricted lateral, vertical, and peripheral expansion during the heating and coolingcycle without damage or strain to any part. The heat exchanger shall be designed to prevent contamination of heated air with the products ofcombustion. A spring loaded pressure relief door with glass view port shall be provided. The entire heater casing shall be lined with a 22 gauge liner.
Burner
The heater shall have of a power type 409 stainless steel burner, with integral combustion air blower and motor; combustion air proving switch,removable pilot assembly and positive pilot combustion air supply. The combustion air damper shall be interlocked with the main gas valve to insure a proper air/gas mixture. A solid state programmable safeguard relay with UV Scanner and purge card shall continuously monitor main and pilot flame. The main and pilot valve train to the burner shall be completely factory prepiped. This assembly shall be wired and include the following minimumcomponents; main and automatic shut off valves and adequate unions and test ports for service. A 6,000 volt transformer shall accomplish ignition ofpilot flame. The unit shall be suitable for natural gas and designed and certified by ETL and C.G.A to provide full gas modulation. Depending on theburner selection, turndown from 100% to 7% of output are achievable.
Electrical Control Equipment
Electrical assembly and components shall be in strict accordance with the latest provisions and requirements of the Nation Electric Code. Controlcabinet shall be designed and constructed to ETL specifications. A dead front safety disconnect switch shall be mounted on the control enclosure door.Electrical cabinets shall be NEMA 12. The cabinets shall be located in a weather proof cabinet. Provisions for service padlocking shall be provided. Thefollowing items shall be located within the electrical enclosure: fuses, starters, control relays, timing and holding relays, resistors and numbered terminalstrips. All components shall be labeled and cross referenced to control and field wiring diagrams. The control circuit shall be 110V, single phase. Wiringshall be neatly run in “PANDUIT” wiring duct. Low and/or line voltage thermostats shall be furnished shipped loose for installation by others. Unit shallbe equipped with automatic low limit freeze protection with bypass timer. Unit will feature a convenience outlet with separate disconnect, circuit breakerprotection and supply transformer. Temperature control shall consist of a solid state PID loop with adjustable setpoints. A discharge temperature sensorshall be wired in series-parallel to room sensor. The temperature control system may be controlled by DDC at any time during operation. DDC systemmay take control of blower/burner/dampers and modulating gas valve.
Remote Control Panels
Remote NEMA 12 locking stainless steel control panels shall be equipped with summer or winter switch and blower on, burner on, flame failure andloaded filter lights. A remote adjustment potentiometer shall control damper positioning. A LCD display shall provide system temperature and setpoints.
Mix Box and Filter Section
A mix box with fresh air and return air dampers shall be provided. The dampers are to be aluminum airfoil low leak type with seals. The dampers are tobe inset into 22 gauge steel mix box liners. The dampers shall be equipped with modulation actuators.
The blower section shall include a motor operated outside air intake sized for 100% outside air. The filters shall be 2" pleated throwaway type withminimum of 85% arrestance and 30% dust. Filter access shall be through a latched and gasketed access doors located on both sides of the unit.
Typical Specification for a GIDM Unit INDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD.
BMADirect Gas-Fired makeup Air Units
OSDDirect Fired Makeup
Air/Curing Units
IMAIndustrial
Gas-Fired Units
GIDMIndirect
Gas-Fired Units
h 100% makeup air and 80/20 units
h Stainless steel burner
h DX or evaporative cooling section option
h 30:1 turndown ratio
h Recirculating & Dual Air Dual Temperature Sequence
h Exceptional spray booth control packages using PLCs
h Booth balancing option with variable frequency drive on exhaust
h Premium makeup air/curing units for the refinishing industry
h 100% makeup air & 80/20 units
h Suitable for any automotive or high-end industrial applications
h Backward inclined blowers standard on sizes 140 and up
h Four-pass drum and tube industrial grade stainless steel heat exchanger
h Industrial quality forced draft power burner
h High efficiency (80%) and excellent durability
h JIC wiring available for the automotive industry
HTDMHigh Turndown
Indirect-Fired Units
MTIIndirect
Gas-Fired Units
ACAir Turnover Units
CUSTOMBUILTUNITS
h Stainless steel two-pass drum and tube heat exchanger with forced draft power burner
h Best turndown ratio for power burners in the industry (Up to 60:1)
h Inputs of 200, 400, 600, 1000 & 1500 MBH
h Up to 85% (minimum efficiency)
h Indoor or Outdoor packaged indirect-fired heating systems
h Stainless steel heat exchanger suitable for 100% outside air
h Excellent temperature control through brand name components
h Wide variety of configuration options
h Superior serviceability through design and simplistic operation
h Vertical air turnover heating systems
h An effective and economical solution to heating, ventilating or conditioning large spaces
h Four-pass indirect-fired heat exchanger
h Optional A-coil cooling section
h ICE has the capability to build a wide variety ofcustom-built units for any type of commercial orindustrial application
h Specializing in heat recovery and custom air handler with heating or cooling coils
INDUSTRIAL COMMERCIAL
EQUIPMENT MANUFACTURING LTD.
ICE MANUFACTURING LTD.
51 Aikins Street
Winnipeg, Manitoba
Canada R2W 4E3
Tel: (204) 586-8565
Fax: (204) 589-7682
www.ice-ww.com
ICE (U.S.) INC.
Industrial Park
Bolivar, Tennessee
United States 38008
Tel: (731) 658-7000
Fax: (731) 658-3090
www.ice-us.com
Printed in Canada
EXCELLENCE THROUGH
PROVEN PERFORMANCE