EXCELLENCE THROUGH PROVEN PERFORMANCE GIDM Indirect-Fired Heating and Ventilating Units INDUSTRIAL COMMERCIAL EQUIPMENT MANUFACTURING LTD. ® US GIDM0406BR

Upload: others

Post on 24-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

EXCELLENCE THROUGH PROVEN PERFORMANCE

GIDM Indirect-Fired Heatingand Ventilating Units

INDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD.

®

US

GIDM0406BR

Page 2: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

INDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD.

Originally founded as Bullocks Manufacturing during the post-war residential

housing boom, I.C.E. Manufacturing was recognized for innovation and

excellence early in our history. After the company established a reputation for

designing, manufacturing and installing natural gas conversion burners for oil

and coal-fired furnaces, founder Don Bullocks returned from an ASHRAE trade

show with a natural gas line burner. Inspired, he set out to manufacture the first

direct-fired makeup air unit in his home country of Canada.

Today, the natural gas revolution continues with I.C.E. Manufacturing at the

forefront of the commercial direct-fired industry. Don had the vision long before

many others by designing a product that has outlived his legend. Our BMA

Series is named for him (Bullocks Makeup Air). This forward thinking has carried

on through such advanced products as the HTDM, the gas valve technology

available on the BMA, and the industrial-quality GIDM product line.

All of our products have withstood the test of time. Many new products are on

the horizon to meet the ever-increasing concern over energy costs, consumption

and impact on our environment. We are building on our heritage to bring

exceptional gas-fired products to market.

I.C.E. is committed to success – the success of our customers and our

employees. To us, success is driven by loyalty that comes from service, quality

and innovation. With our vast experience in the HVAC industry, we continue to

listen to and understand the needs of our customers. And we trust we will be

able to serve you well into the future.

EXCELLENCE THROUGH PROVEN PERFORMANCE

Page 3: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

Table of Contents

APPLICATION GUIDE FOR INDIRECT FIRED GIDM/GIDMH SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

STANDARD FEATURES / OPTIONAL FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

GIDM SERIES TEMPERATURE CONTROL PACKAGES / MISCELLANEOUS CONTROL OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

AMPERAGE SPECIFICATIONS / STATIC PRESSURE DUE TO ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

FILTER SECTION SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

WEIGHT SPECIFICATIONS (POUNDS). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

GIDM PERFORMANCE SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W ANGULAR FILTER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W V-BANK FILTER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W V-BANK FILTER SECTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W ANGULAR FILTER SECTION AND MIX BOX . . . . . . . . . . . . . . . . . . . . . . 17

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX . . . . . . . . . . . . . . . . . . . . . . . . . . 18

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX . . . . . . . . . . . . . . . . . . . . . . . . . 19

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W V-BANK FILTER SECTION AND MIX BOX. . . . . . . . . . . . . . . . . . . . . . . . 20

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W V-BANK FILTER SECTION AND MIX BOX . . . . . . . . . . . . . . . . . . . . . . 21

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND DX COIL. . . . . . . . . . . . . . . . . . . . . . . . . . . 22

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND DX COIL . . . . . . . . . . . . . . . . . . . . . . . . . 23

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION, MIX BOX AND DX COIL . . . . . . . . . . . . . . . . . . 24

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION, MIX BOX AND DX COIL . . . . . . . . . . . . . . . . . 25

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX WITH RELIEF . . . . . . . . . . . . . . . 26

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX WITH RELIEF . . . . . . . . . . . . . 27

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX WITH RELIEF

AND RETURN AIR BLOWER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION, MIX BOX WITH RELIEF

AND RETURN AIR BLOWER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH FLAT FILTER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . 30

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH ANGULAR FILTER SECTION. . . . . . . . . . . . . . . . . . . . . 31

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH V-BANK FILTER SECTION. . . . . . . . . . . . . . . . . . . . . . . 32

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH FLAT FILTER SECTION AND MIX BOX . . . . . . . . . . . . . 33

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH ANGULAR FILTER SECTION AND MIX BOX . . . . . . . . 34

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH V-BANK FILTER SECTION AND MIX BOX . . . . . . . . . . 35

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH FLAT FILTER SECTION AND DX COIL . . . . . . . . . . . . . 36

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNIT GRAVITY VENTED WITH FLAT FILTER SECTION, DX COIL AND MIX BOX . . . . . 37

GIDM SERIES HORIZONTAL CONFIG. OUTDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION AND MIX BOX WITH RELIEF

AND RETURN AIR BLOWER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

GIDMH SERIES HORIZONTAL CONFIG. OUTDOOR UNIT GRAVITY VENTED C/W FLAT FILTER SECTION, MIX BOX WITH RELIEF

AND RETURN AIR BLOWER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

GIDM/GIDMH MODULATING MANIFOLD ARRANGEMENT FOR CGA, ETL, F.M., AND I.R.I. APPROVAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Page 4: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

Application Guide For Indirect Fired GIDM/GIDMH Series

• GIDM unit models are designated by their MBH output. Thus a GIDM 75 has 750 MBH output, or 750,000 BTUH.

• All GIDM units are 80% efficient at high fire, thus, output is BTUH input * 0.80

• Once you have chosen your required BTUH output, you can use BTUH output/0.80 to find your required input, or actual gas consumption. Using the desired output you can select your model.

• Choose your airflow (this may be your first step if the unit is applied in a make-up air situation)

• Calculate your TSP (add your ESP with your accessories – accessory pressure drops can be found on page 6). With your airflow and TSP selectedyou can find your BHP from the charts on pages 10-12

• Unit weights can be found on page 8 & 9

• Given the entering and leaving air dry bulb temperatures or temperature rise, the equation below can be used to calculate the required MBH capacity

MBH Capacity = (CFM x C x (LAT-EAT))/0.80/1000

MBH capacity: BTUH/1000 (British Thermal units per hour)

CFM: Cubic Feet per minute of air

C: Gas constant of 1.08 based on air density at 75 deg. F

EAT: Entering air dry bulb temperature (deg. F)

LAT: Leaving air dry bulb temperature (deg. F)

0.8: GIDM Series Efficiency

Example For Make-Up Air

A manufacturing facility needs pressurization via make-up air. 10% pressurization is deemed to be appropriate and it is determined that 25,720 CFMexhaust is required. -20 deg. F is the design ambient, and desired discharge temp is 70 deg. F. Units will be roof mounted, down discharge, and willhave an ESP of 0.60" W.C. Select the appropriate GIDM model, and find the BHP for the unit.

Selection:

• Since we are exhausting 25,720 CFM, and desire 10% pressurization, we can calculate that we need 28,300 CFM of supply air (25,720 + 10% = 28300)

• We know our EAT = -20 deg. F, and LAT = 70 deg. F, thus we can calculate:

• MBH Output Capacity = (CFM x C x (LAT-EAT))/1000

• MBH Output Capacity = (28,300 x 1.08 x (70 - (-20)))/1000

• MBH Output Capacity = 2,750.00

• The closest model available is the GIDM 275 which has 2,750 MBH output, and 3,437.5 MBH input

We can now calculate our TSP:

• We are selecting the basic options – inlet filters and damper

• Inlet damper = 0.1" W.C (Page 6)

• Inlet Filters = 0.3" W.C (Page 6)

• TSP = ESP + Accessories

• TSP = 0.60 + 0.1 + 0.3

• TSP = 1.0" W.C.

• Consulting the chart for the GIDM 275 (page 12) at 28,300 CFM and 1.0" W.C we find our BHP = 16.28 BHP – Thus we need a 20.0 HP motor minimum.

Example for Heat-Vent Unit

A small warehouse needs a minimum of 20% fresh air in unoccupied (night time) mode and 100% fresh air in occupied mode (during the day with forkliftin the building). It has been calculated that at -30 deg. F the room loses 1,000,000 BTUH. It has been determined that 11,000 CFM is required for theapplication. The outdoor air is -30 deg. F, and desired leaving air is 75 deg. F. Return air will be 70 deg. F. ESP is calculated to be 0.5" W.C. Select theappropriate model and find the BHP for the unit.

Selection:

Part 1 (Unoccupied mode)

• We only bring in 20% outside air in this mode, thus 2200 CFM is outside air and 8800 CFM is return air

• We know our EAT for outside air = -30 deg. F, and LAT = 75 deg. F, thus we can calculate:

• MBH Capacity = (CFM x C x (LAT-EAT))/1000

• MBH Capacity = (2,200 x 1.08 x (75 - (-30)))/1000

• MBH Capacity = 249.48

• We also know that the room is losing 1,000 MBH, thus we need to add that to the calculation. Thus the total Heat input capacity required = 1,250 MBH

• Before we select our model we must check the occupied mode to ensure we have sufficient heat capacity.

2

Page 5: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

Part 2 (Occupied mode)

• We will be delivering 11,000 CFM of outside in this mode

• We know our EAT for outside air = -30 deg. F, and LAT = 75 deg. F, thus we can calculate:

• MBH Capacity = (CFM x C x (LAT-EAT))/0.80/1000

• MBH Capacity = (11,000 x 1.08 x (75 - (-30)))/0.80/1000

• MBH Capacity = 1,247.40

• Thus to satisfy both options we need to use a GIDM 125.

Note: In this example we are assuming there is an alternate source of heat that will be used during occupied mode to make-up for the heat loss of thewarehouse, which will not be used in un-occupied mode.

We can now calculate our TSP:

• We are selecting the basic options – inlet filters and damper

• Inlet damper = 0.1" W.C (Page 6)

• Inlet Filters = 0.3" W.C (Page 6)

• TSP = ESP + Accessories

• TSP = 0.50 + 0.1 + 0.3

• TSP = 0.9" W.C. (Round up to 1.0" W.C)

• Consulting the chart for the GIDM 125 (page 10) at 11,000 CFM (Use 11,574 CFM) and 1.0" W.C we find our BHP = 5.75 BHP – We can use a 7.5 hp motor.

Example for a Heating Only Unit

A door heater for a large overhead door can potentially see 100% fresh air during times when the overhead doors open frequently. Thus a durable GIDMunit should be selected for this application. 18,000 CFM at 0.5" W.C is determined to be the appropriate amount of air for the vestibule, and 1250 MBHis calculated to be the appropriate amount of heat capacity required. Select the appropriate model and find the BHP for the unit.

Selection:

• Since the heating load calculation has already been completed we simply need to use the heating capacity and match it up with the appropriateGIDM model

• A GIDM 125 is the appropriate model for 1250 MBH

We can now calculate our TSP:

• We are selecting the basic options – inlet filters and damper

• Inlet damper = 0.1" W.C (Page 6)

• Inlet Filters 0.3" W.C (Page 6)

• TSP = ESP + Accessories

• TSP = 0.50 + 0.1 + 0.3

• TSP = 0.9" W.C. (Round up to 1.0" W.C)

• Consulting the chart for the GIDM 125 (page 10) at 18,000 CFM (this value falls between 16,534 CFM and 19,290 CFM) and 1.0" W.C we find ourBHP is between 9.59 BHP and 13.12 BHP. A 15 HP motor should be used.

3

Application Guide For Indirect Fired GIDM/GIDMH Series

Page 6: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

Standard Features

4

Mix BoxAllows the recirculation of air to occur. This willprovide a cost effective way of space heating.

Weatherhousing Control and manifold enclosureComes with hinged access completely sealed withTrimseal gasketing and ventlock handles

Inlet HoodsExpanded metal screen inlet.

Filter SectionFlat, Angular or V-bank filter section with sideaccess suitable for 2" filters. Hinged access doors completely sealed with Trimseal gasketing for all models.

Winter Filter SectionLocated on the discharge side of heating section.

Filters2" thick permanent, pleated and throwaway filters;various efficiency bag filters and HEPA filterscomplete with filter gauge and/or indicating light.

Motorized Inlet & Discharge DamperParallel blade damper with a two-position springreturn actuator and end switch.

Roof CurbPrefabricated galvanized roof curb 16" or 24" high;full perimeter available on most units.

BlowersBackward inclined, air foil, and plug fans

DX PlenumCoil located in vertical or horizontal airflowcomplete with drain pan when applicable.

Coil PlenumsHeating coils – steam, hot water, and glycol Cooling coils – chilled water, DX coil

Evaporative CoolersIndustrial and commercial

Hinged Access DoorsStandard on filter section, motor section andweatherhousing. Comes with #140 ventlockhandles, #310 ventlock handles on GIDM 125 and up

Mushroom HoodComplete with internal screen for debris

Louvered InletFlush mountedGalvanized steel blades complete with an internalscreen for debris

4-Way Discharge HeadThe adjustable 4 way discharge head provides 4 equal quantities of air in the conditioned space

Horizontal Discharge Head180 deg. vertical and horizontal adjustment with360 deg. of free rotation

Internal Vibration IsolationBlower and motor isolated on separate frame withR.I.S. or spring c/w canvas connector

External Vibration IsolationFloor mounted or suspended isolation

Service PlatformProvides access to controls and gas train

MotorsTEFC and high-efficiency, meeting EEE and CSAstandards and 2-speed

Disconnect SwitchWeatherproof enclosure; non-fused or fused

FM Gas TrainMeets Factory Mutual (FM) requirements

IRI Gas TrainMeets Industrial Risk Insurers requirements

High Gas Pressure RegulatorRequired on natural gas with pressure in excess of5 psig and LP applications in excess of 11" W.C.

High/Low Gas Pressure SwitchesManual reset, gas pressure safety switches whichlock out the burner in the event of gas pressuremalfunction.

Control PanelsNEMA4 or 12 custom, unit mounted or remoteenclosuresExplosion proof panels

Standard Features

Optional Features

Assurance

• ETL listed, CGA listed

• Factory wired, piped, and test fired

Cabinet

• Welded structural or formed channel base frame primed with rust inhibitor

• Lifting lugs

• Heavy gauge colorbond steel casing with rust-resistant grey enamel paint finish

• One inch thick 1.5# density neoprene coated fiberglass

• The insulation is glued and pinned, solid liner in the burner section

• Two inch insulation is recommended on GIDM 125 & larger

• Unit comes with standard 2" breaks on GIDM 125 & larger

• Sloped roof standard on GIDM 125 and up

Blower/Motor

• AMCA rated forward curve DWDI centrifugal blower

• Polished steel shaft with rust inhibitor

• Maximum operating speed less than 75% of first critical speed

• Standard heavy-duty industrial bearings used on unit with blower sizes20x20 and larger

• Sealed cartridge bearings provided on units with blower sizes 18x18 and smaller.

• ODP motor, 1800 RPM, T frame, 1.15 service factor mounted onadjustable base

• Drives designed for 150% motor brake horsepower

• Adjustable V-belt drives used up to and including 5 HP; fixed drives on 7.5 HP and larger

Burner/Manifold

• Gas, propane or oil power burner

• Factory pre-piped, wired and flame tested

• CGA/ANSI approved 7-14" W.C. gas train

• CGA approved turndown of 7% of output, approximately 15:1 turndown

• Inlet pressure for propane 11" W.C.

Heat Exchanger Section

• Four pass continuously welded 400 series primary with mild steelsecondary heat exchanger

• Five year heat exchanger warranty

• Fully lined and insulated radiation shield

• Direct drive radial blade induced draft blower

• Puff door w/inspection sight glass

Controls Enclosure

• Electronic flame safeguard relay manual reset

• Manual reset high limit

• Factory wired control panel with numbered terminal strip

• Motor starter with overloads

• Control circuit transformer, 120 volt

• Control panel service switch

• Circuit breaker

• Terminal connections for exhaust interlock

• Nationally recognized components, service, and parts

Additional Options

• Auto low limit freeze protectioncontrol with bypass timer

• 10 point electronic circuit analyzer with signal lights

• Exhaust Interlock Relay

• Proof of Closure Valve

• Inlet Air Controller (burner economizer)

• Ultra violet flame supervision

• Audible alarm

• Null pressure switch

• Firestat

• Purge timer

• Delay exhaust start

• 115 volt GFI service receptacle

• Marine service light with 100 wattbulb, guard, and lighted switch

• High density insulation

• 2" thick and 4" thick insulation

• Motor and bearings out of airstream

• Internal liners – 22 gauge solid or perforated

• JIC wiring

• Extended grease lines

• Belt guards

• Checker plate floor

• Walk-in service corridors

• Corrosion resistant two-step acrylic finish

• Special coatings

• Special construction: aluminum,stainless steel, heavier gauges

Page 7: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM Series Temperature Control PackagesBuilding makeup air systems maintain a constant supply air temperature to the space using a discharge temperature controller. The burner output ismodulated over a wide range to compensate for fluctuations in the incoming ambient air temperature. A gas valve regulates output according to thedemand sensed by a discharge air sensor. The fan and heat system functions are typically controlled by a remote panel with a system andsummer/winter switch or a building management system.

Types of Gas Valve Control Available

A) Modulating Discharge Air Temperature ControlThis type consists of a discharge air sensor in the discharge of the unit. The temperature set point is set at the unit and the burner will then modulate tomaintain this discharge temperature.

B) Modulating Discharge Air Temperature Control with Remote Manual Adjustment (RTS)This type consists of a modulating discharge air sensor and a remote temperature selector. The operation of this type is the same as the above (A).However the discharge temperature may be remotely adjusted by the remote temperature selector.

C) Modulating Discharge Air Temperature Control with Remote Temperature Adjustment and Space Override (Brings Unit to Full Fire)This type consists of a modulating discharge air sensor, remote temperature selector, and a space override temperature stat. This is commonly usedwhere there is wide, fast indoor temperature fluctuations (eg. garage) and/or where fine temperature control is not essential, and/or when thetemperature rise is low (eg. 40 deg. F or less). The operation is the same as above (B) however when the space stat requires heat the furnace goes to fullfire regardless of the discharge temperature, until the space thermostat is satisfied.

D) Modulating Discharge Air Temperature Control with Remote Manual Adjustment (RTS'S) and Space Thermostat for Resetting Discharge Air Temperature SettingsThis type consists of a modulating discharge air sensor, a remote temperature selector for first temperature setting (eg. 75 deg. F), a second remotetemperature selector for Override setting (eg. 90 deg. F) and a space thermostat for switching. This type is used where there is moderate indoortemperature fluctuations and/or where fine temperature control is essential and/or when the unit temperature rise is high. The operation is the same as inC however the second remote temperature selector limits the discharge air temperature when the space thermostat calls for full fire. The burner willmodulate to maintain the second set point until the space thermostat is satisfied.

Note: The space stat may be replaced with dry contacts to allow a building management system to do the switching.

E) Building Management Control InterfaceThis type consists of a DDC Gas modulating interface (0-10Vdc or 4-20mA). This allows a building management system to tie into the unit controls. Thebuilding management system now controls the discharge temperature of the unit and the burner will modulate to maintain that temperature.

F) Modulating Space Thermostat with Auto Discharge Temperature ResetThis type consists of a modulating duct stat and a modulating space stat. This type is used where space loads continuously change. This system willautomatically adjust the discharge temperature to accommodate for the load changes providing precise space temperature control.

Miscellaneous Control Options

Freeze ProtectionSpecified to protect against untempered air entering the space. The freeze thermostat, also known as an auto low limit, is located in the discharge airand is wired in parallel with a time delay relay. In the event that the discharge air temperature is not above the freeze thermostat setting, within a presettime during start-up and under normal operation the unit will shut down.

Inlet Air ControllerFeatures an adjustable thermostat which monitors outdoor air temperatures. When the temperature exceeds the setting of the thermostat, the burner willnot operate even when the unit is in the winter mode.

Night SetbackThis feature is available as an option on all temperature control systems. By lowering the discharge air temperature requirements during unoccupiedperiods the owner can realize operating economies and still provide heat to the space as required. During the occupied cycle the unit will be brought onthough an interlock, timeclock or switch. During the unoccupied period the timeclock provided, switches the system control to a single stage thermostatset at the desired unoccupied temperature. The unit will then be started intermittently to provide heat to maintain the space at the unoccupiedtemperature setpoint.

5

Page 8: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

Amperage Specifications

6

MOTORRUNNING MOTOR AMPERAGE

VOLTAGE/PHASE/CYCLES

HP 115/1/60 230/1/60 208/3/60 230/3/60 416/3/60 460/3/60 575/3/60

1/4 5.60 2.80 N/A N/A N/A N/A N/A

1/3 5.80 2.90 N/A N/A N/A N/A N/A

1/2 8.40 4.20 2.20 2.00 1.10 1.00 0.80

3/4 12.00 6.00 3.00 2.50 1.50 1.38 1.10

1 16.00 8.00 3.10 3.25 1.80 1.63 1.30

1 1/2 20.00 10.00 5.25 4.75 2.60 2.38 1.90

2 24.00 12.00 6.60 6.00 3.30 3.00 2.40

3 34.00 17.00 9.60 8.75 4.80 4.38 3.50

5 56.00 28.00 15.10 13.75 7.60 6.88 5.50

7 1/2 80.00 40.00 24.00 21.75 12.00 10.88 8.70

10 100.00 50.00 28.90 26.25 14.50 13.13 10.50

15 N/A N/A 44.20 40.00 22.10 20.00 16.00

20 N/A N/A 58.00 52.50 29.00 26.25 21.00

25 N/A N/A 74.50 67.50 37.30 33.75 27.00

30 N/A N/A 85.60 77.50 42.80 38.75 31.00

40 N/A N/A 115.90 105.00 58.00 52.50 42.00

50 N/A N/A 146.30 132.50 73.00 66.25 53.00

60 N/A N/A 165.60 150.00 82.80 75.00 60.00

75 N/A N/A 204.40 185.00 102.10 92.50 74.00

100 N/A N/A 270.50 245.00 135.20 122.50 98.00

125 N/A N/A 339.50 307.00 169.70 153.75 123.00

NOTES:

• To Calculate the Inrush Motor Amp. Draw = Running Motor Amperage x 2.5

• To Calculate the Full Load Amps (FLA) = 1.25 x Largest Motor Draw + Additional Motor Draw at Face Value + Control Amperage (1.00 Amps Generally Cover 90% of MUA Applications).

• If You Require Specific Control Amperages Please Contact the Factory.

NOTES:

• Accessory Static Pressure Drops are Calculated at Maximum CFM Loads.

ACCESSORIES STATIC PRESSURE DROP(IN INCHES WATER)

FLAT AND ANGULAR FILTER SECTION 0.4

INLET HOOD 0.1

INLET LOUVER 0.2

EVAPORATIVE COOLER (COMMERCIAL) 0.3

EVAPORATIVE COOLER (INDUSTRIAL) 0.4

INLET DAMPER 0.1

DX PLENUM AND COIL 0.6

WINTER FILTER (V-BANK) 0.6

NORMAL FILTER (V-BANK) 0.6

80/20 MIX BOX W/FILTERS 0.7

HORIZONTAL DISCHARGE HEAD 0.5

WAY DISCHARGE HEAD 0.5

Static Pressure Due to Accessories

Page 9: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

7

Filter Section Summary

MODEL

STANDARD V-BANK HIGH CFM V-BANK

QUANTITY - SIZEINCHES

TOTAL FILTERFREE AREA

FT2

MAXIMUMAIR FLOW

CFMMODEL

QUANTITY - SIZEINCHES

TOTAL FILTERFREE AREA

FT2

MAXIMUMAIR FLOW

CFM

GIDM 20/25 3 - 2 x 25 x 20 10.42 5,210 GIDMH 20/25 4 - 2 x 20 x 25 19.44 9,7202 - 2 x 16 x 25

GIDM 35/40 4 - 2 x 25 x 20 13.88 6,940 GIDMH 35/40 4 - 2 x 20 x 25 25 12,5004 - 2 x 16 x 25

GIDM 45/55 4 - 2 x 20 x 25 19.44 9,720 GIDMH 45/55 12 - 2 x 20 x 25 41.67 20,8352 - 2 x 16 x 25

GIDM 65/75 6 - 2 x 20 x 25 26.39 13,195 GIDMH 65/75 15 - 2 x 20 x 25 52.08 26,0402 - 2 x 16 x 25

GIDM 85/100 9 - 2 x 20 x 25 39.58 19,790 GIDMH 85/100 20 - 2 x 20 x 25 69.4 34,7203 - 2 x 16 x 25

GIDM 125/175 16 - 2 x 20 x 25 66.67 33,335 GIDMH 125/175 30 - 2 x 20 x 25 104 52,0804 - 2 x 16 x 25

GIDM 200/250 20 - 2 x 20 x 25 80.56 40,280 GIDMH 200/250 48 - 2 x 20 x 25 166.6 83,3304 - 2 x 16 x 25

GIDM 275/325 30 - 2 x 20 x 25 118.06 59,030 GIDMH 275/325 48 - 2 x 20 x 25 189 94,4005 - 2 x 16 x 25 8 - 2 x 20 x 20

GIDM 350/400 35 - 2 x 20 x 25 135.42 67,710 GIDMH 350/400 60 - 2 x 20 x 25 263.9 131,9005 - 2 x 16 x 25 20 - 2 x 20 x 20

GIDM 500/600 48 - 2 x 20 x 25 183.33 91,665 GIDMH 500/600 80 - 2 x 20 x 25 361.11 180,5556 - 2 x 16 x 25 30 - 2 x 16 x 25

MODEL

STANDARD V-BANK HIGH CFM V-BANK

QUANTITY - SIZEINCHES

TOTAL FILTERFREE AREA

FT2

MAXIMUMAIR FLOW

CFMMODEL

QUANTITY - SIZEINCHES

TOTAL FILTERFREE AREA

FT2

MAXIMUMAIR FLOW

CFM

GIDM 20/25 1 - 2 x 20 x 25 3.47 1,735 GIDMH 20/25 2 - 2 x 20 x 25 9.72 4,8601 - 2 x 16 x 25

GIDM 35/40 2 - 2 x 20 x 25 6.94 3,470 GIDMH 35/40 6 - 2 x 16 x 20 13.3 6,665

GIDM 45/55 1 - 2 x 16 x 25 9.71 4,855 GIDMH 45/55 3 - 2 x 20 x 20 21.25 10,6252 - 2 x 20 x 25 3 - 2 x 16 x 20

1 - 2 x 20 x 25 1 - 2 x 16 x 25

GIDM 65/75 3 - 2 x 20 x 25 13.18 6,590 GIDMH 65/75 4 - 2 x 20 x 25 25 12,5001 - 2 x 16 x 25 4 - 2 x 16 x 25

GIDM 85/100 6 - 2 x 20 x 25 20.8 10,400 GIDMH 85/100 9 - 2 x 20 x 25 31.20 15,600

GIDM 125/175 12 - 2 x 16 x 25 33.3 16,650 GIDMH 125/175 12 - 2 x 20 x 25 41.665 20,833

GIDM 200/250 10 - 2 x 20 x 25 40.24 20,120 GIDMH 200/250 18 - 2 x 20 x 25 62.5 31,2502 - 2 x 16 x 25

GIDM 275/325 6 - 2 x 20 x 20 58.3 29,150 GIDMH 275/325 10 - 2 x 16 x 25 78.50 39,25012 - 2 x 20 x 25 14 - 2 x 20 x 25

1 - 2 x 16 x 20

GIDM 350/400 3 - 2 x 16 x 20 65 32,500 GIDMH 350/400 1 - 2 x 16 x 20 91.39 45,69512 - 2 x 20 x 25 21 - 2 x 20 x 256 - 2 x 20 x 20 4 - 2 x 16 x 25

GIDM 500/600 3 - 2 x 16 x 25 91.66 45,830 GIDMH 500/600 4 - 2 x 16 x 20 117.22 58,61024 - 2 x 20 x 25 4 - 2 x 20 x 20

28 - 2 x 20 x 25

MODEL

STANDARD V-BANK HIGH CFM V-BANK

QUANTITY - SIZEINCHES

TOTAL FILTERFREE AREA

FT2

MAXIMUMAIR FLOW

CFMMODEL

QUANTITY - SIZEINCHES

TOTAL FILTERFREE AREA

FT2

MAXIMUMAIR FLOW

CFM

GIDM 20/25 1 - 2 x 25 x 16 6.25 3,125 GIDM 125/175 12 - 2 x 20 x 25 50 25,0001 - 2 x 25 x 20 3 - 2 x 16 x 25

GIDM 35/40 1 - 2 x 16 x 25 11.25 5,625 GIDM 200/250 16 - 2 x 25 x 20 64.44 32,2201 - 2 x 16 x 20 4 - 2 x 16 x 201 - 2 x 20 x 201 - 2 x 20 x 25

GIDM 45/55 4 - 2 x 20 x 20 15.5 7,750 GIDM 275/325 24 - 2 x 20 x 20 75.56 37,7782 - 2 x 16 x 20 4 - 2 x 16 x 20

GIDM 65/75 6 - 2 x 20 x 20 21.11 10,555 GIDM 350/400 28 - 2 x 20 x 25 108.33 54,1652 - 2 x 16 x 20 4 - 2 x 16 x 25

GIDM 85/100 6 - 2 x 20 x 25 26.39 13,193 GIDM 500/600 40 - 2 x 20 x 25 152.78 76,3882 - 2 x 16 x 25 5 - 2 x 16 x 25

NOTES:

• The Static Pressure Drop Through the V-Bank Filters is Approximately 0.6 W.C. (Clean) and Approximately 1.00" W.C. (Dirty).

• The Maximum Airflow is Calculated so the Velocity Across the Filters Never Exceeds 500 FPM.

NOTES:

• The Static Pressure Drop Through the Flat and Angular Filters is Approximately 0.4" W.C (Clean) and Approximately 0.8" W.C. (Dirty).

• The Maximum Airflow is Calculated so the Velocity Across the Filters Never Exceeds 500 FPM.

GENERAL FILTER PERFORMANCE NOTES:

• The Standard Filter Selection May Contain One of the Three Types:

Replaceable: 2 Inch Fiberglass Media with an Average Efficiency of 20% at 500 FPM.

Throwaway: 2 Inch Pleated Media with an Average Efficiency of 30% at 500 FPM.

Permanent: 2 Inch Media with Layers of Slit and Expanded Aluminum. The Media Efficiency Averages 20% at 500 FPM. The Media can be Cleaned Using a Stream of Water

Page 10: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

Weight Specifications (Pounds)

8

MODEL BLOWER SEC.HEAT

EXCHANGERSECTION

FLAT FILTERSECTION

V-BANKSECTION

MIX BOXWEATHERHOUSING

RETURN AIRBLOWER SEC.

GIDM 20/25 615 895 N/A 165 200 240 615

GIDM 35/40 755 1020 125 205 260 240 755

GIDM 45/55 950 1295 130 235 335 270 950

GIDM 65/75 1365 1560 130 295 420 270 1365

GIDM 85/100 1545 2125 140 320 495 300 1545

GIDM 125/175 2190 2840 305 360 710 350 2190

GIDM 200/250 2880 3445 375 440 935 425 2880

GIDM 275/325 3600 4590 400 465 1055 500 3600

GIDM 350/400 4145 5695 440 525 1250 650 4145

GIDM 500/600 5565 8935 670 795 1555 675 5565

Horizontal Units

MODEL BLOWER SEC.HEAT

EXCHANGERSECTION

FLAT FILTERSECTION

V-BANKSECTION

MIX BOXWEATHERHOUSING

RETURN AIRBLOWER SEC.

GIDM 20/25 665 845 N/A 165 200 240 615

GIDM 35/40 805 970 125 205 260 240 755

GIDM 45/55 1000 1245 130 235 335 270 950

GIDM 65/75 1425 1500 130 295 420 270 1365

GIDM 85/100 1635 2035 140 320 495 300 1545

GIDM 125/175 2300 2730 305 360 710 350 2190

GIDM 200/250 3000 3325 375 440 935 425 2880

GIDM 275/325 3740 4450 400 465 1055 500 3600

GIDM 350/400 4295 5545 440 525 1250 650 4145

GIDM 500/600 5885 8615 670 795 1555 675 5565

Vertical Units

MODEL INLET HOODRELIEFHOOD

DISCHARGENOZZLES

STANDARD

SERVICEPLATFORM

GIDM 20/25 60 40 75 585

GIDM 35/40 70 50 75 620

GIDM 45/55 90 50 100 690

GIDM 65/75 110 60 125 690

GIDM 85/100 160 60 125 730

GIDM 125/175 255 100 170 810

GIDM 200/250 315 110 215 835

GIDM 275/325 490 145 260 925

GIDM 350/400 575 160 300 1025

GIDM 500/600 710 170 450 1315

Accessories

Page 11: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

9

MODEL BLOWER SEC.HEAT

EXCHANGERSECTION

FLAT FILTERSECTION

V-BANKSECTION

MIX BOXW/ RELIEF

MIX BOXW/ RELIEF

GIDM

GIDMH 20/25 860 910 N/A 250 390 220

GIDMH 35/40 1040 1035 190 315 500 290

GIDMH 45/55 1325 1340 200 380 505 380

GIDMH 65/75 1740 1625 200 440 785 480

GIDMH 85/100 1885 2160 200 450 880 580

GIDMH 125/175 2580 2885 415 485 1185 825

GIDMH 200/250 3375 3490 500 590 1550 1100

GIDMH 275/325 4120 4640 515 590 1705 1270

GIDMH 350/400 4715 5790 565 655 1940 1500

GIDMH 500/600 6185 9035 805 970 2385 1875

Horizontal Units

MODEL BLOWER SEC.HEAT

EXCHANGERSECTION

FLAT FILTERSECTION

V-BANKSECTION

MIX BOXW/ RELIEF

MIX BOXW/ RELIEF

GIDM

GIDMH 20/25 860 910 N/A 250 390 220

GIDMH 35/40 1040 1035 190 315 500 290

GIDMH 45/55 1325 1340 200 380 505 380

GIDMH 65/75 1740 1625 200 440 785 480

GIDMH 85/100 1885 2160 200 450 880 580

GIDMH 125/175 2580 2885 415 485 1185 825

GIDMH 200/250 3375 3490 500 590 1550 1100

GIDMH 275/325 4120 4640 515 590 1705 1270

GIDMH 350/400 4715 5790 565 655 1940 1500

GIDMH 500/600 6185 9035 805 970 2385 1875

Vertical Units

MODEL INLET HOODRELIEFHOOD

SERVICEPLATFORM

GIDMH 20/25 90 60 585

GIDMH 35/40 105 75 620

GIDMH 45/55 135 75 690

GIDMH 65/75 150 90 690

GIDMH 85/100 220 90 730

GIDMH 125/175 335 150 810

GIDMH 200/250 410 165 835

GIDMH 275/325 610 220 925

GIDMH 350/400 700 240 1025

GIDMH 500/600 855 255 1315

Accessories

Weight Specifications (Pounds)

Page 12: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM Performance Specifications

10

GIDM 20 - 250 MBH INPUT/200 MBH OUTPUT

AirCapacity

(CFM)

4630 40 1.70 1.94 2.17 2.42 2.94 4.28

3704 50 1.47 1.67 1.87 2.08 2.49 2.90

3086 60 1.28 1.44 1.63 1.82 2.17 2.58

2646 70 0.90 1.06 1.22 1.37 1.73 2.13

2315 80 0.69 0.83 0.96 1.12 1.64 1.99

2058 90 0.55 0.67 0.82 0.97 1.39 1.72

1852 100 0.45 0.57 0.71 0.93 1.52 1.52

1684 110 0.39 0.51 0.7 0.87 1.05 1.24

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 25 - 312.5 MBH INPUT/250 MBH OUTPUT

AirCapacity

(CFM)

5787 40 2.91 3.19 3.48 3.77 4.37 4.99

4630 50 1.70 1.94 2.17 2.42 2.94 4.28

3858 60 1.62 1.82 2.02 2.24 2.67 3.09

3307 70 1.53 1.66 1.87 2.08 2.46 2.83

2894 80 1.09 1.27 1.44 1.61 1.95 2.37

2572 90 0.85 1.01 1.16 1.3 1.67 2.27

2315 100 0.69 0.83 0.96 1.12 1.64 1.99

2104 110 0.58 0.69 0.84 0.99 1.43 1.79

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 40 - 500 MBH INPUT/400 MBH OUTPUT

AirCapacity

(CFM)

9259 40 7.13 6.62 10.33 10.77 11.78 12.82

7407 50 3.59 4.00 5.22 5.56 6.27 7.00

6173 60 2.35 3.14 3.43 3.73 4.34 4.97

5291 70 1.96 2.21 2.47 2.73 3.28 3.84

4630 80 1.45 1.68 1.91 2.15 2.64 3.99

4115 90 1.12 1.33 1.54 1.76 2.80 3.26

3704 100 1.36 1.53 1.72 1.93 2.34 2.74

3367 110 1.08 1.26 1.44 1.63 1.99 2.81

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 35 - 437.5 MBH INPUT/350 MBH OUTPUT

AirCapacity

(CFM)

8102 40 4.49 4.93 5.37 5.82 6.73 7.66

6481 50 2.63 3.53 3.83 4.14 4.78 5.43

5401 60 2.06 2.32 2.58 2.85 3.40 3.97

4630 70 1.45 1.68 1.91 3.08 3.54 4.02

4051 80 1.09 2.00 2.19 2.40 2.81 3.24

3601 90 0.87 1.59 1.77 1.96 2.34 2.73

3241 100 1.16 1.32 1.72 1.89 2.22 2.55

2946 110 0.99 1.32 1.47 1.62 1.92 2.22

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 45 - 562.5 MBH INPUT/450 MBH OUTPUT

AirCapacity

(CFM)

10417 40 5.17 5.69 6.23 6.78 7.94 9.16

8333 50 4.13 4.57 5.02 5.48 6.40 8.31

6944 60 2.68 3.06 3.44 4.46 5.12 5.81

5952 70 1.90 2.66 2.94 3.22 3.81 4.42

5208 80 1.75 1.99 2.24 2.50 3.03 3.58

4630 90 1.34 1.57 1.80 2.03 2.52 3.04

4167 100 1.07 1.28 2.09 2.32 2.77 3.24

3788 110 1.39 1.54 1.74 1.93 2.37 3.39

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 55 - 687.5 MBH INPUT/550 MBH OUTPUT

AirCapacity

(CFM)

12731 40 7.24 7.98 8.79 9.61 11.40 19.59

10185 50 4.90 5.41 5.94 6.48 7.62 10.68

8488 60 4.31 4.77 5.22 5.68 6.62 7.57

7275 70 2.98 3.38 3.77 4.17 4.99 5.83

6366 80 2.21 3.12 3.40 3.70 4.32 4.96

5658 90 1.71 2.38 2.64 2.92 3.48 4.06

5093 100 1.66 1.90 2.15 2.40 2.92 3.52

4630 110 1.34 1.57 1.80 2.77 3.23 3.70

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 65 - 812.5 MBH INPUT/650 MBH OUTPUT

AirCapacity

(CFM)

12037 50 5.82 6.39 6.97 7.57 8.79 10.03

10031 60 3.73 4.22 4.72 7.31 8.31 9.32

8598 70 2.64 4.47 4.89 5.32 6.19 7.09

7523 80 2.00 3.36 3.74 4.12 4.91 5.72

6687 90 2.34 2.67 3.53 3.87 4.56 5.24

6019 100 1.91 2.59 2.90 3.21 3.83 4.53

5471 110 1.89 2.17 2.45 2.73 3.29 4.85

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 75 - 937.5 MBH INPUT/750 MBH OUTPUT

AirCapacity

(CFM)

13889 50 8.39 9.02 8.82 10.35 11.72 13.12

11574 60 5.27 5.82 6.39 6.96 8.14 9.35

9921 70 3.64 4.13 4.62 5.13 6.18 8.94

8681 80 2.70 4.37 4.79 5.22 6.11 7.01

7716 90 2.11 3.35 3.74 4.13 4.93 5.76

6944 100 2.33 2.67 3.03 3.39 4.13 5.39

6313 110 1.89 2.65 2.97 3.29 3.94 4.58

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

NOTES:

• All Static Values Include the Blower, Burner, and Casing

• Accessory Static Values Must be Added to Obtain the Total Static (see pg. 5)

• Brake Horsepower Does Not Include Drive Losses

Consult factory for:

• Higher Air Capacities or Special Applications

• Performance Data on Higher Statics than Listed

• Performance Data at Elevations Other Than Sea Level

Page 13: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

11

GIDM 175 - 2187.5 MBH INPUT/1750 MBH OUTPUT

AirCapacity

(CFM)

32407 50 21.80 23.34 24.90 26.50 29.79 33.22

27006 60 13.62 17.11 18.35 19.61 22.19 24.88

23148 70 10.76 11.82 12.91 14.02 16.35 18.79

20255 80 7.77 8.72 9.70 10.72 12.86 15.14

18004 90 5.91 6.78 10.40 11.36 13.31 15.29

16204 100 4.70 7.48 8.35 9.22 11.00 12.80

14731 110 3.85 6.10 6.90 7.70 9.33 11.00

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1 1/2

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 85 - 1062.5 MBH INPUT/850 MBH OUTPUT

AirCapacity

(CFM)

19676 40 12.83 13.87 14.93 15.99 18.13 20.30

15741 50 7.35 8.20 9.05 9.91 11.67 13.45

13117 60 4.82 5.54 7.36 7.98 9.25 10.56

11243 70 3.46 4.75 5.29 5.84 6.96 8.13

9838 80 3.10 3.57 4.05 4.54 5.56 8.49

8745 90 2.41 2.84 4.74 5.16 6.04 7.95

7870 100 1.94 3.55 3.84 4.23 5.04 5.87

7155 110 1.61 2.86 3.21 3.58 4.33 5.68

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 100 - 1250 MBH INPUT/1000 MBH OUTPUT

AirCapacity

(CFM)

23148 40 17.14 18.22 19.33 20.43 22.71 25.00

18519 50 10.97 11.96 12.96 13.96 15.99 18.04

15432 60 7.02 7.85 8.69 9.54 11.26 13.02

13228 70 4.89 5.62 7.49 8.10 9.38 10.70

11574 80 3.66 5.05 5.60 6.16 7.31 8.50

10288 90 3.45 3.93 4.43 4.94 5.99 9.03

9259 100 2.72 3.17 3.63 5.58 6.49 7.44

8418 110 2.22 2.64 4.17 4.59 5.44 6.32

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1 1/4

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 125 - 1562.5 MBH INPUT/1250 MBH OUTPUT

AirCapacity

(CFM)

28935 40 16.22 17.62 19.04 20.51 23.54 26.74

23148 50 10.76 11.82 12.91 14.02 16.35 18.79

19290 60 6.92 7.84 12.09 13.12 15.20 17.30

16534 70 4.90 7.81 8.70 9.59 11.39 13.23

14468 80 5.10 5.87 6.65 7.45 9.05 10.70

12860 90 3.97 4.66 6.51 7.08 8.31 9.59

11574 100 3.21 4.68 5.20 5.75 6.89 8.07

10522 110 2.65 3.80 4.30 4.81 5.87 6.97

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1 1/4

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 150 - 1875 MBH INPUT/1500 MBH OUTPUT

AirCapacity

(CFM)

34722 40 24.50 28.64 29.94 31.31 34.04 36.90

27778 50 14.66 18.40 19.66 20.95 23.59 26.33

23148 60 10.76 11.82 12.91 14.02 16.35 18.79

19841 70 7.39 8.32 9.29 13.93 16.05 18.21

17361 80 5.46 6.30 9.63 10.57 12.45 14.37

15432 90 4.23 6.72 7.55 8.39 10.09 11.82

13889 100 4.68 5.43 6.18 8.34 9.63 10.98

12626 110 3.81 4.49 6.24 6.81 8.03 9.28

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1 1/2

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 200 - 2500 MBH INPUT/2000 MBH OUTPUT

AirCapacity

(CFM)

46296 40 22.66 24.60 26.59 28.65 33.03 43.86

37037 50 16.18 17.89 19.64 21.46 25.24 29.26

30864 60 10.50 11.98 18.83 20.30 23.32 26.48

26455 70 7.48 12.13 13.40 16.70 19.16 21.73

23148 80 7.95 10.46 11.52 12.60 14.84 17.21

20576 90 6.12 8.05 9.01 10.01 12.10 14.33

18519 100 5.62 6.47 7.37 8.30 13.24 15.26

16835 110 4.56 5.36 8.41 9.31 11.14 13.00

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

1 1/2

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 250 - 3125 MBH INPUT/2500 MBH OUTPUT

AirCapacity

(CFM)

57870 40 35.59 38.28 41.04 43.88 49.81 56.07

46296 50 22.66 24.60 26.59 28.65 33.03 43.86

38580 60 17.89 19.67 21.48 23.34 27.23 31.34

33069 70 12.31 13.87 22.10 23.65 26.84 30.14

28935 80 9.08 14.91 16.28 17.67 20.56 23.60

25720 90 7.08 11.42 14.56 15.74 18.15 20.67

23148 100 7.95 10.46 11.52 12.60 14.84 17.21

21044 110 6.43 8.46 9.44 10.45 12.56 14.82

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

2

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

NOTES:

• All Static Values Include the Blower, Burner, and Casing

• Accessory Static Values Must be Added to Obtain the Total Static (see pg. 5)

• Brake Horsepower Does Not Include Drive Losses

Consult factory for:

• Higher Air Capacities or Special Applications

• Performance Data on Higher Statics than Listed

• Performance Data at Elevations Other Than Sea Level

GIDM Performance Specifications

Page 14: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM Performance Specifications

12

GIDM 275 - 3437.5 MBH INPUT/2750 MBH OUTPUT

AirCapacity

(CFM)

50926 50 25.65 27.71 29.79 31.90 36.30 40.99

42438 60 16.62 22.96 24.90 26.86 30.92 38.36

36376 70 14.36 16.02 17.72 19.47 23.14 27.04

31829 80 10.18 11.65 18.78 20.25 23.28 26.43

28292 90 8.08 9.44 14.93 16.28 19.10 22.07

25463 100 6.52 10.76 11.98 15.01 17.39 19.87

23148 110 7.65 8.75 11.22 12.30 14.52 16.87

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

2

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 300 - 3750 MBH INPUT/3000 MBH OUTPUT

AirCapacity

(CFM)

55556 50 28.02 30.52 33.08 35.71 41.22 47.07

46296 60 20.61 22.51 24.44 26.43 30.62 35.17

39683 70 14.12 19.58 21.41 23.27 27.15 31.23

34722 80 12.89 14.48 16.12 17.82 21.40 25.22

30864 90 9.81 11.26 18.13 19.59 22.58 25.71

27778 100 7.77 13.03 14.34 15.68 18.46 21.40

25253 110 6.38 10.53 13.56 14.71 17.08 19.55

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

2 1/2

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 325 - 4062.5 MBH INPUT/3250 MBH OUTPUT

AirCapacity

(CFM)

60185 50 34.40 37.07 39.79 42.58 48.37 54.48

50154 60 25.26 27.31 29.38 31.48 35.86 40.52

42989 70 17.13 18.91 20.73 27.59 31.68 35.96

37616 80 15.59 17.30 19.04 20.84 24.58 28.55

33436 90 11.78 13.32 14.92 23.37 26.55 29.85

30093 100 9.29 10.72 17.15 18.58 21.52 24.60

27357 110 7.55 12.62 13.91 17.52 20.03 22.64

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

2 1/2

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 350 - 4375 MBH INPUT/3500 MBH OUTPUT

AirCapacity

(CFM)

81019 40 48.29 51.64 55.00 58.39 65.33 72.56

64815 50 29.42 32.21 35.04 37.92 43.92 54.90

54012 60 21.86 24.20 26.59 29.04 34.15 39.61

46296 70 15.21 20.08 21.98 23.90 27.90 32.21

40509 80 13.18 14.84 20.55 22.41 26.24 30.27

36008 90 10.07 14.39 16.05 17.74 21.30 25.10

32407 100 10.02 11.50 13.02 20.82 23.90 27.09

29461 110 8.12 9.49 15.60 16.98 19.85 22.85

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

2 1/2

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 400 - 5000 MBH INPUT/4000 MBH OUTPUT

AirCapacity

(CFM)

92593 40 CONSULT FACTORY

74074 50 41.31 44.50 47.68 50.90 57.47 64.32

61728 60 26.05 28.72 35.91 38.63 44.22 40.07

52910 70 20.86 23.16 25.51 27.92 32.99 38.40

46296 80 15.21 20.08 21.98 23.90 27.90 32.21

41152 90 13.69 15.37 21.28 23.16 27.04 31.11

37037 100 10.72 15.30 16.99 18.72 22.34 26.19

33670 110 10.90 12.43 14.00 15.62 25.81 22.73

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

3

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 500 - 6250 MBH INPUT/5000 MBH OUTPUT

AirCapacity

(CFM)

115741 40 139.7

92593 50 77.06 84.76

77160 60 42.40 49.27 55.92 62.71

66138 70 29.63 32.48 40.88 46.66 52.60

57870 80 19.47 21.95 28.17 41.38 35.91 41.38

51440 90 14.86 19.69 21.95 28.06 32.30 36.69

46296 100 13.76 15.77 20.61 28.34 32.55 36.87

42088 110 11.13 15.11 16.84 23.11 27.01 31.07

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

3

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

GIDM 600 - 7500 MBH INPUT/6000 MBH OUTPUT

AirCapacity

(CFM)

138889 40

111111 50 127.1

92593 60 77.06 84.76

79365 70 45.35 52.60 59.43 66.37

69444 80 30.61 36.18 37.17 45.24 51.58

61728 90 20.87 25.31 32.48 35.16 40.61 46.29

55556 100 17.69 23.37 25.78 33.23 37.78 42.41

50505 110 14.24 18.89 24.88 26.95 31.12 35.47

Temp.Rise

0.25"W.C.

BHP BHP BHP BHP BHP BHP

3

0.5"W.C.

0.75"W.C.

1.0"W.C.

1.5"W.C.

2.0"W.C.

GasConn.Inches

NOTES:

• All Static Values Include the Blower, Burner, and Casing

• Accessory Static Values Must be Added to Obtain the Total Static (see pg. 5)

• Brake Horsepower Does Not Include Drive Losses

Consult factory for:

• Higher Air Capacities or Special Applications

• Performance Data on Higher Statics than Listed

• Performance Data at Elevations Other Than Sea Level

CONSULT FACTORY, REQUIRESFAN SIZE GREATER THAN2-36x36

CONSULT FACTORY, REQUIRESFAN SIZE GREATER THAN2-36x36

Page 15: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 13

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

P

FILTERSFRESH AIR

DAMPER

POWER BURNER

UI

D K

UI

FRESH AIRFLOW

SUPPLY AIROPTION

PUFFDOOR

SIDE VIEW

OPTIONSUPPLY AIR

SPRING ISOLATOR

M

T

BLOWERSC

A B

G

COM

BUST

ION

PATH

PANELCONTROL

SUPPLY AIROPTION

TOP VIEW

FOUR PASSCOMBUSTION CHAMBER

L

U

H

W

NMIN.

CLEARANCE

UI

U

O

3

V

FLEXCONN.

4TYP.

Z HINGED DOORACCESS c/wHANDLE

A

UNITS UP TO GIDM 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECE SHIPPING

NOTES:

A SIZE 65/75 AND UP SPLIT FOR SHIPMENT

MOTOR

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

72GIDM 125/175 75

GIDM 500/600

GIDM 350/400

GIDM 275/325

GIDM 200/250

87

107

92

80

84

100

141

72

GIDM 45/55

GIDM 35/40

GIDM 20/25

GIDM 85/100

GIDM 65/75

MODEL

68

62

67

60

62

55

47

55

52

A

47

B

9154100 413091 2432

140

160

180

120

65

80

70

60

36

36

36

36

131

168

148

111

32

32

32

32

30

48

30

30 111

168

148

131 52

67

57

47

80

80

60

48

48

36

36

32

32

C

32

D

30

30

30

30

71

71

51

39

30

G

23

H

20

20

20

18

18

18

18

18

18

I

18

K

71

71

51

39

35

23

23

19

23

L

19

M

121590 12

16

20

15

140

120

120

120

-

-

12

12

14

14

6

6

9

9

15

7

7

O

40

40

70

80

40

N

18

18

18

12

18

P

12

12

12

10

10

T U

124

2

6

6

4

4 14

18

16

12

2

4

3

3

3

12

10

10

8

3

V

8

W Z

17 12

11 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 16: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNITGRAVITY VENTED c/w ANGULAR FILTER SECTION

TITLE

14NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

PFILTERSFRESH AIR

DAMPER

POWER BURNER

UI

D K

UI

FRESH AIRFLOW

SUPPLY AIROPTION

PUFFDOOR

SIDE VIEW

OPTIONSUPPLY AIR

SPRING ISOLATOR

M

T

BLOWERSC

A B

G

COM

BUST

ION

PATH

PANELCONTROL

SUPPLY AIROPTION

TOP VIEW

FOUR PASSCOMBUSTION CHAMBER

L

U

H

W

NMIN.

CLEARANCE

UI

U

O

3

V

FLEXCONN.

4TYP.

Z HINGED DOORACCESS c/wHANDLE

A

UNITS UP TO GIDM 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECE SHIPPING

NOTES:

A SIZE 65/75 AND UP SPLIT FOR SHIPMENT

MOTOR

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

72GIDM 125/175 75

GIDM 500/600

GIDM 350/400

GIDM 275/325

GIDM 200/250

87

107

92

80

84

100

141

72

GIDM 45/55

GIDM 35/40

GIDM 20/25

GIDM 85/100

GIDM 65/75

MODEL

68

62

67

60

62

55

47

55

52

A

47

B

9154100 413091 2432

140

160

180

120

65

80

70

60

36

36

36

36

131

168

148

111

32

32

32

32

30

48

30

30 111

168

148

131 52

67

57

47

80

80

60

48

48

36

36

32

32

C

32

D

30

30

30

30

71

71

51

39

30

G

23

H

20

20

20

18

18

18

18

18

18

I

18

K

71

71

51

39

35

23

23

19

23

L

19

M

121590 12

16

20

15

140

120

120

120

-

-

12

12

14

14

6

6

9

9

15

7

7

O

40

40

70

80

40

N

18

18

18

12

18

P

12

12

12

10

10

T U

124

6

6

4

4 14

18

16

12

2

2

4

3

3

3

12

10

10

8

3

V

8

W Z

17 12

11 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 17: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 15

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w V-BANK FILTER SECTION

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

NMIN.

CLEARANCE

A

G

POWER BURNERFRESH AIR

DAMPER

DFRESH AIRFLOW

M

SPRING ISOLATOR

MOTOR

FILTERS

U

CL BLOWERS

P

K

SUPPLY AIROPTION

PUFFDOOR

I

I

PANELCONTROL

U

U

SUPPLY AIROPTION

SUPPLY AIROPTION

H

COM

BUST

ION

PATH

W

IB

FOUR PASSCOMBUSTION CHAMBER

U

TOP VIEW

SIDE VIEW

U

4TYP.

Z

OV

3

FLEXCONN.

HINGED DOORACCESS c/wHANDLE

A

UNITS UP TO GIDM 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECE SHIPPING

NOTES:

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT.

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

39

23

71

51

91

71

131

168

148

111

141

100

GIDM 200/250

GIDM 500/600

GIDM 350/400

GIDM 275/325

92

95

117

101

GIDM 125/175

GIDM 45/55

GIDM 35/40

GIDM 20/25

GIDM 85/100

GIDM 65/75

MODEL

68

67

72

85

75

A

62

84

72

160

180

120

140

70

80

60

65

36

36

36

36

148

168

111

131

32

32

32

32 30

30

48

30

47 48

72

62

55

55

100

80

60

80

B

47

C

32

32 30

54

48

36

36

32

30

30

30

D

32

G

30

39 18

91

71

51

71

30

20

20

20

H

23

I

18

18

18

18

24

18

18

K

3

V

3

3

4

4

3

4

4

6

667

57

52

47

120

140

120

120

20

16

15

-

-

12

12

14 6

6

19

41

35

23

23

L M

19

40 7

90

80

40

70

15

15

9

9

N

40

O

7

18 10

12

12

18

18

12

14

12

12

12

P

18

T

10

U

2

2

12

14

18

16

Z

8

10

10

12

12

8

W

T

17 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

11 12

Page 18: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNITGRAVITY VENTED c/w V-BANK FILTER SECTION

TITLE

16NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

TOP VIEW

FOUR PASSCOMBUSTION CHAMBER

B

SIDE VIEW

POWER BURNER

D

FRESH AIRFLOW

M

SPRING ISOLATOR

FILTERSFRESH AIR

DAMPER

A

U

MOTOR

BLOWERS

K

T

U

U

I

I

OPTIONSUPPLY AIR

SUPPLY AIROPTION

PUFFDOOR

PANELCONTROL

SUPPLY AIROPTION

COM

BUST

ION

PATH

NMIN.

CLEARANCE

U

H

W

A

G

I

P

O

M

19

23

19

35

47

52

23

57

67

84 72GIDMH 125/175

GIDMH 200/250

GIDMH 275/325

GIDMH 350/400

GIDMH 500/600

95

102

98

90

84

141

100

72

GIDMH 65/75

GIDMH 85/100

GIDMH 20/25

GIDMH 35/40

GIDMH 45/55

MODEL

60

55

60

55

55

62

47

55

52

A

47

B

123 412491 3060 32132

176

216

196

156

71

76

86

66

36

36

36

36

131

171

151

111

32

32

42

32

35

30

48

30 147

167

184

204

110

110

90

78

54

42

42

38

C

62

D

38

30

30

30

30

71

71

51

39

30

G

23

H

20

20

20

18

18

18

18

18

18

I

18

K

101

101

81

69

53

L

12618100

20

21

140

140

140

140 -

-

6

6

14

14

6

O

9

11

9

18

12

40

40

80

60

N

40

12

12

4

8

12

P

12

12

12

10

10

T U

4

4

6

6

4

14

16

18

12

12

2

2

4

3

3

3

12

10

10

8

3

V

8

W Z

U

V

3

FLEXCONN.

4TYP.

ZHINGED DOORACCESS c/wHANDLE

NOTES:

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT

UNITS UP TO GIDM 45/55 WILL HAVETURNED BASE RAILS TO ALLOW FOR 1 PIECESHIPPING.

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

C

L

17 12

27 12 11 1

2

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

6 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 19: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 17

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w ANGULAR FILTER SECTION AND MIX BOX

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

TOP VIEW

SIDE VIEW

I

I

U

U

K

T

D

SUPPLY AIR

POWER BURNER

RETURN AIROPTION

RETURN AIROPTION

SUPPLY AIR

PUFFDOOR

CONTROLPANEL

OPTION

OPTIONSUPPLY AIR

V

3

FRESH AIRDAMPER

M

SPRING ISOLATOR

FILTERS

MOTOR

P

FRESH AIRFLOW

OPTION

72GIDM 125/175 75

GIDM 500/600

GIDM 350/400

GIDM 275/325

GIDM 200/250

87

107

92

80

84

100

141

72

GIDM 45/55

GIDM 35/40

GIDM 20/25

GIDM 85/100

GIDM 65/75

MODEL

68

62

67

60

62

55

47

55

52

A

47

B

9154100 413091 2432

140

160

180

120

65

80

70

60

36

36

36

36

131

168

148

111

32

32

32

32

30

48

30

30 111

168

148

131 52

67

57

47

80

80

60

48

48

36

36

32

32

C

32

D

30

30

30

30

71

71

51

39

30

G

23

H

20

20

20

18

18

18

18

18

18

I

18

K

71

71

51

39

35

23

23

19

23

L

19

M

121590 14739 12

44

44

41

41

16

20

15

140

120

120

120

-

-

12

12 171

248

192

153

14

14

6

6

29

29

29

27

27

Q

9

9

15

7

7

O

40

40

70

80

40

N

18

18

18

12

18

P

130

117

107

122

99

S

12

12

12

10

10

T U

124

6

6

4

4 14

18

16

12

2

2

4

3

3

3

12

10

10

8

3

V

8

W Z

O

FLEXCONN.

NOTES:

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT

UNITS UP TO GIDM 45/55 WILL HAVETURNED BASE RAILS TO ALLOW 1 PIECESHIPPING

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

SECTIONMIX BOX

COM

BUST

ION

PATH

BLOWERS

G

C

FOUR PASSCOMBUSTION CHAMBER

L

U

S

NMIN.

CLEARANCE

W

A BQ

U

4TYP.

Z

HINGED DOORACCESS c/wHANDLE

AA

H

U I

17 12

11 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 20: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND MIX BOX

TITLE

18NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

TOP VIEW

SIDE VIEW

I

UI

U

K

G

A

C

D

B

FRESH AIRFLOW

SUPPLY AIR

POWER BURNER

RETURN AIROPTION

RETURN AIROPTION

SUPPLY AIROPTION

PUFFDOOR

CONTROLPANEL

OPTION

OPTIONSUPPLY AIR

FOUR PASSCOMBUSTION CHAMBER

COM

BUST

ION

PATH

V

3

U

L

U

FRESH AIRDAMPER

M

SPRING ISOLATOR

FILTERSP

T

S

IN

MIN.CLEARANCE

BLOWERS

Q

H

W

U

4TYP.

Z

O

RETURN AIRDAMPER

MOTOR

FLEXCONN.

HINGED DOORACCESS c/wHANDLE

AA

UNITS UP TO GIDM 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECE SHIPPING

NOTES:

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT

SECTIONMIX BOX

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

GIDM 125/175

GIDM 200/250

GIDM 275/325

GIDM 350/400

GIDM 500/600

GIDM 65/75

GIDM 85/100

GIDM 20/25

GIDM 35/40

GIDM 45/55

M

19

19

23

23

35

47

57

67

52

75 72

107

92

80

87

141

100

72

84

MODEL

62

68

67

60

55

62

55

47

52

A

47

B

32 2491 30100 54 91 41

180

160

120

140

70

80

60

65

36

36

36

36

148

168

111

131

32

32

32

32

48

30

30

30 131

148

168

111

80

80

48

60

36

48

32

36

C

32

D

32

30

30

30

30

71

71

39

51

30

G

23

H

20

20

20

18

18

18

18

18

18

I

18

K

39

71

71

51

23

L

1239 14790 15 12

15

20

16

120

120

120

140

12

12

-

-

44

44

41

41

248

192

153

171

14

14

6

6

7

7

1580

70

40

40

N

40

12

18

18

189

9

18

O P

29

29

29

27

117

130

122

107

27

Q

99

S

12

12

12

10

10

T U

4 12

6

6

4

4

16

18

12

14

2

2

4

3

3

3

12

10

10

8

3

V

8

W Z

17 12

11 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 21: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 19

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND MIX BOX

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

TOP VIEW

SIDE VIEW

I U

UI

K

G

A

C

D

V

B

FRESH AIRFLOW

SUPPLY AIR

POWER BURNER

RETURN AIROPTION

RETURN AIROPTION

SUPPLY AIROPTION

PUFFDOOR

CONTROLPANEL

OPTION

OPTIONSUPPLY AIR

FOUR PASSCOMBUSTION CHAMBER

COM

BUST

ION

PATH

FRESH AIRDAMPER

FILTERS

SPRING ISOLATOR

M

3

T

S

L

MOTOR

BLOWERS

Q

U I

H

NMIN.

CLEARANCE

W

P

O

TURNED BASE RAILS TO ALLOW FOR 1 PIECEUNITS UP TO GIDMH 45/55 WILL HAVE

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT

SHIPPING

NOTES:

110

110

132

156

176

196

216

GIDMH 45/55

GIDMH 85/100

GIDMH 65/75

GIDMH 275/325

GIDMH 500/600

GIDMH 350/400

GIDMH 200/250

GIDMH 125/175

47

50

57

60

65

68

77

84

100

141

55

62

72

72

GIDMH 35/40

GIDMH 20/25

40

37

47

47

47

55

62

78

90

86

76

71

36

36

36

66

60

54

42

36

32

30

30

171

151

131

42

32

32

111

91

71

71

32

30

20

20

48

35

30

204

184

167

24

30

18

18

147

123

101

101

67

52

57

140

140

140

41

47

23

35

140

100

60

80

38

38

42

30

30

30

23

39

51

18

18

20

18

18

18

53

69

81

19

19

23

40

40

40

21

20

-

-

18

12

18

6

6

6

4

8

149

168

21344

44

41

97

112

129

13341

39

29

29 3

4

4

4

6

4

614

14

6

12

12

12

18

16

14

12

12

12

10

9

9

11

12

12

12

87

84

102

27

27

29

3

3

3

10

10

12

8

8

10

2

2

U U

RETURN AIRDAMPER

FLECCONN.

4TYP.

Z

AA

SECTIONMIX BOX

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

MODEL A B C D G H I K L M N O P Q S VT U W Z

17 12

27 12 11 1

2

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

6 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 22: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w V-BANK FILTER SECTION AND MIX BOX

TITLE

20NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

TOP VIEW

SIDE VIEW

UI

UI

K

G

A

C

D

B

FRESH AIRFLOW

POWER BURNER

RETURN AIROPTION

RETURN AIROPTION

SUPPLY AIROPTION

PUFFDOOR

CONTROLPANEL

SUPPLY AIROPTION

OPTIONSUPPLY AIR

FOUR PASSCOMBUSTION CHAMBER

COM

BUST

ION

PATH

V

3

U

U

FRESH AIRDAMPER

M

L

SPRING ISOLATOR

FILTERS P

T

S

I

NMIN.

CLEARANCE

BLOWERS

Q

H

W

GIDM 500/600

GIDM 350/400 100

141

101

117

160

180 80

70

36

36

GIDM 45/55

GIDM 35/40

GIDM 20/25

GIDM 125/175

GIDM 85/100

GIDM 275/325

GIDM 200/250

GIDM 65/75

47

55

47

62

72

84

72

5567

85

92

95

75

MODEL

68

72

62

A

3080 36

100

140

120

80

3254

65

60

36

36

48 30

48

60

B

32

C

3032

36 30

32

D

30

G

32148

168 32 48

30

168

148

67

57 120

140

201

25816 -

-

44

44

14

14

6 6

6

71 20 18

20

32

32

3091

111

131

71

24

30

30

18

20

39

51

H

23

18 18

18

18

I

18

K

71 23 70

4191

131

111

52

47

71 35

90

120

120

80

1939

51 23

23

L

19

M

40

40

40

N

109

115

127

137

165

179

157

1229 29

15

15

39

41

41

29

7

12

9

12

7

O

18

P

27

29

27

Q S

12 3

12

12

4

4

4

4

10

12

10

T

3

3

U

3

V

18

16

2

2

10

12

14

12

12

10

8

8

W Z

U

O

4TYP.

Z

MOTOR

FLEXCONN.

RETURN AIRDAMPER

HINGED DOORACCESS c/wHANDLE

AA

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT.

15

20

12

12

18

18

18

6

NOTES:

UNITS UP TO GIDM 45/55 WILL HAVETURNED BASE RAILS TO ALLOW 1 PIECESHIPPING

SECTIONMIX BOX

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

17 12

11 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 23: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 21

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w V-BANK FILTER SECTION AND MIX BOX

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

NMIN.

CLEARANCE

SUPPLY AIRD

Q

C

I

UI

U

K

A B

FRESH AIRFLOW

SUPPLY AIR

POWER BURNER

RETURN AIROPTION

RETURN AIROPTION

OPTIONSUPPLY AIR

PUFFDOOR

OPTION

CONTROLPANEL

OPTION

FOUR PASSCOMBUSTION CHAMBER

COM

BUST

ION

PATH

V

SPRING ISOLATOR

M

3

FRESH AIRDAMPER

FILTERS

T

BLOWERS

L

MOTOR

H

W

G

SIDE VIEW

TOP VIEW

P

O

GIDMH 500/600

GIDMH 350/400 100

141

98

102

196

216 86

76

36

36

GIDMH 45/55

GIDMH 35/40

GIDMH 20/25

GIDMH 125/175

GIDMH 85/100

GIDMH 275/325

GIDMH 200/250

GIDMH 65/75

47

55

47

62

72

84

72

5555

84

90

95

65

MODEL

55

60

52

A

30110 42

132

176

156

110

3260

71

66

36

36

54 30

78

90

B

62

C

3038

42 30

38

D

30

G

32151

171 42 48

30

204

184

67

57 140

140

198

24321 -

-

44

44

14

14

6 6

6

71 20 18

20

32

32

3091

111

131

71

24

35

30

18

20

39

51

H

23

18 18

18

18

I

18

K

101 23 60

41123

167

147

52

47

101 35

100

140

140

80

1969

81 23

53

L

19

M

40

40

40

N

99

102

115

122

163

179

156

110812 29

18 6

20

6

6

18 4

39

41

41

29

9 12

11 12

9

O

12

P

27

29

27

Q S

12 3

12

12

4

4

4

4

10

12

10

T

3

3

U

3

V

18

16

2

2

10

12

14

12

12

10

8

8

W Z

S

UU

U I

RETURN AIRDAMPER

HINGED DOORACCESS c/w

HANDLE

A A

FLEXCONN.

4TYP.

Z

A SIZE 65/75 AND UP SPLIT FOR SHIPMENT

NOTES:

UNITS UP TO GIDMH 45/55 WILL HAVETURNED BASE RAILS TO ALLOW 1 PIECESHIPPING

SECTIONMIX BOX

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

17 12

27 12 11 1

2

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

6 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 24: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND DX COIL

TITLE

22NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

OPTIONSUPPLY AIR

I U

UI

K

G

A

C

D

B

FRESH AIRFLOW

POWER BURNER

SUPPLY AIROPTION

OPTION

PUFFDOOR

CONTROLPANEL

FOUR PASSCOMBUSTION CHAMBER

COM

BUST

ION

PATH

SUPPLY AIR

U

DXCOIL

DRAINPAN

SPRING ISOLATOR

YM

FRESH AIRDAMPER

BLOWERS

T

P

NMIN.

CLEARANCE

XL H

W

I U

SIDE VIEW

TOP VIEW

100

141

102GIDM 275/325

GIDM 350/400

GIDM 500/600

102

94

GIDM 65/75

GIDM 85/100

GIDM 20/25

GIDM 35/40

GIDM 45/55

GIDM 125/175

GIDM 200/250

MODEL

98

102

92

100

82

A

97

90

3032131366514084

36

36180

160

80

70

168

148

32

32

48

30

30

30

30

30

30

36

32

72

72

62

55

120

100

80

80

55

47

47

B

48

60

32

C

60

54

36

48

36

32

32

D G

71

71

91

111

23

H

51

39

32

30

20

20

30

24

18

18

20

18

18

I

18

18

18

K U

6

6

1212052131

57

67168

148

140

120

16

20 -

- 14

14

19

19

23

23

35

47

M

111

91

71

71

41

51

39

23

L

70

80

90

120

40

40

40

N

15

15

15

9

12

12

18

12

9

7

7

O

18

18

18

P

12

12

12

12

10

10

T

144

6

6

18

16

2

2

4

4

4

3

V

3

3

3

12

12

12

10

10

8

8

W Z

125

145

165

65

102

85

65

X

23

45

22

56

71

61

27

39

45

51

23

27

23

Y

U

OV

3

FLEXCONN.

FILTERS

AHINGED DOORACCESS c/w

HANDLE (typ)

4TYP.

Z

NOTES:

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT

UNITS UP TO 45/55 WILL HAVETURNED BASE RAILS TO ALLOW 1 PIECESHIPPING

SECTIONBLOWER/FILTER/COIL

SECTIONHEAT EXCHANGER

17 12

11 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 25: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 23

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND DX COIL

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

SIDE VIEW

V

I

I

U

U

K

A

C

D

B

FRESH AIRFLOW

SUPPLY AIR

POWER BURNER

SUPPLY AIROPTION

PUFFDOOR

CONTROLPANEL

OPTION

OPTIONSUPPLY AIR

FOUR PASSCOMBUSTION CHAMBER

COM

BUST

ION

PATH

SPRING ISOLATOR

M

3

FRESH AIRDAMPER

YT

DXCOIL

DRAINPAN

X

BLOWERS

L

MOTOR

U

H

W

G NMIN.

CLEARANCE

UI

TOP VIEW

P

O

100

141

GIDMH 275/325

GIDMH 500/600

GIDMH 350/400 98

102

95

GIDMH 45/55

GIDMH 35/40

GIDMH 20/25

GIDMH 85/100

GIDMH 65/75

GIDMH 200/250

GIDMH 125/175

MODEL

72

80

90

87

A

67

70

77

84

216

196

176

86

76

71

36

36

36

151

171

131

42

32

32

48

30

35

G

72

72

62

55

156

132

110

110

47

55

47

B

62

78

90

C

66

60

42

54

36

32

30

30

38

38

42

D

30

30

30

71

71

111

91

H

23

39

51

32

30

20

20

30

24

18

18

18

20

18

I

18

18

18

K U

6204

184

167

67

57

52

140

140

140

21

20

-

-

14

14

18

18

M

147

123

101

101

47

41

35

23

53

69

81

L

19

23

19

60

80

140

100

40

N

40

40

12

6

6

6

8

4

9

11

9

O

12

12

12

P

12

12

12

10

12

10

T

4

6

6

18

16

14

2

2

4

4

4

3

3

3

3

V

12

12

12

10

8

8

10

W Z

201

117

141

161

181

47

75

63

95

95

X

33

44

29

33

29

67

62

57

51

77

Y

U

FILTERS FLEXCONN.

4TYP.

Z AHINGED DOORACCESS c/w

HANDLE (TYP.)

NOTES:

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT

UNITS UP TO 45/55 WILL HAVETURNED BASE RAILS TO ALLOW 1 PIECESHIPPING

SECTIONBLOWER/FILTER/COIL

SECTIONHEAT EXCHANGER

17 12

27 12 11 1

2

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

6 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 26: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION, MIX BOX AND DX COIL

TITLE

24NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

H

P

T

SUPPLY AIR

SUPPLY AIR

U

U

K

I

I

G

A

C

D

B

RETURN AIROPTION

RETURN AIROPTION

POWER BURNER

OPTION

PUFFDOOR

CONTROLPANEL

OPTION

COM

BUST

ION

PATH

FOUR PASSCOMBUSTION CHAMBER

V

FRESH AIRDAMPER

DRAINPAN

DXCOIL

3

M

FILTERS

Y

SPRING ISOLATOR

XL

Q

U

NMIN.

CLEARANCE

BLOWERS

W

OPTION

SIDE VIEW

SUPPLY AIR

TOP VIEW

FLOWFRESH AIR

41

M

47

35

23

23

19

19

67

57

52

72102GIDM 125/175

GIDM 200/250

GIDM 500/600

GIDM 350/400

GIDM 275/325

94 141

102

102

100

84

100

72

MODEL

GIDM 45/55

GIDM 35/40

GIDM 20/25

GIDM 85/100

GIDM 65/75

98

92

97

90

55

62

47

55

82

A B

47

9124309154100 32

80180

140

160

120

65

70

60

16836

36

36

36

131

148

111

4832

32

32

32

30

30

30

168

111

148

131

80

80

60

48

48

36

32

36

C

32

D

32

30

30

30

30

71

71

39

51

30

G

23

H

20

20

20

18

18

18

18

18

18

I

18

K

39

51

71

71

L

23

12412121590

15

20

16140

120

120

120

-

12

12

-

14

14

6

6

186

4

6

4

14

16

12

15

40

40

80

70

N

40

18

18

12

189

9

7

187

O P

12

12

12

10

10

T U

4

3

3

3

12

10

10

8

3

V

8

W

4585

71165

125

145

102

56

61

51

2

2

65

65

45

23

39

27

27

23

22

X

23

Y Z

44

41

44

41

39

29

29

29

27

27

Q

U

4TYP.

Z

O

RETURN AIRDAMPER

FLEXCONN.

MOTOR

HINGED DOORACCESS c/w

HANDLE (TYP)

AA

UNITS UP TO GIDMH 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECE SHIPPING

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT

NOTES:

U I

129

147

160

152

137

186

202

173

235

174

S

S

SECTIONMIX BOX

SECTIONBLOWER/FILTER/COIL

SECTIONHEAT EXCHANGER

17 12

11 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 27: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 25

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION, MIX BOX AND DX COIL

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

OPTIONSUPPLY AIR

NMIN.

CLEARANCE

I

I

U

U

K

G

A

C

D

B

FRESH AIRFLOW

SUPPLY AIR

RETURN AIROPTION

RETURN AIROPTION

POWER BURNER

SUPPLY AIROPTION

OPTION

PUFFDOOR

CONTROLPANEL

COM

BUST

ION

PATH

FOUR PASSCOMBUSTION CHAMBER

V

3

L

FRESH AIRDAMPER FILTERS

SPRING ISOLATOR

DRAINPAN

DXCOIL

M

Y

T

MOTOR

BLOWERS

X

Q

H

W

SIDE VIEW

TOP VIEW

O

P

UU

RETURN AIRDAMPER

FLEXCONN.

HINGED DOOR ACCESS c/w

HANDLE (TYP)

NOTES:

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT

UNITS UP TO GIDMH 45/55 WILL HAVE TURNED BASE RAILS TO ALLOW FOR 1 PIECESHIPPING

IU A A

S

SECTIONMIX BOX

SECTIONBLOWER/FILTER/COIL

SECTIONHEAT EXCHANGER

M

GIDMH 125/175

GIDMH 200/250

GIDMH 350/400

GIDMH 500/600

GIDMH 275/325

102 141

98

95

90

87

100

84

72

72

MODEL

GIDMH 65/75

GIDMH 85/100

GIDMH 20/25

GIDMH 35/40

GIDMH 45/55

4767

80

72

70

77

62

55

47

55

A B

86216

176

196

132

156

71

76

60

66

17136

36

36

32

36

131

151

91

111

4842

32

32

30

32

30

35

30

24

67204

167

184

123

147

57

52

47

41

3862

110

110

90

78

54

42

42

38

C D

2330

30

30

30

30

71

71

51

39

G H

1818

20

20

18

20

18

18

18

18

I K

1953

101

101

69

81

35

23

19

23

L

95

95

63

75

47

181

161

141

117

201

18

20

21140

100

140

140

140

-

6

6

6

-

14

14

6

12

186

4

6

4

4

16

14

12

12

O

9

11

9

12

18

40

80

60

40

40

N

12

12

12

4

8

P

10

12

12

10

12

T U

83

4

3

3

3

12

10

8

10

V W

77

67

62

57

51

2

2

29

44

33

29

33

X Y Z

44

41

44

39

41

29

29

27

29

27

Q

243

198

179

163

156

122

110

99

102

115

S

17 12

27 12 11 1

2

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

6 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 28: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND MIX BOX WITH RELIEF

TITLE

26NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

I

I

U

U

K

G

A

C

D

B

OPTIONRETURN AIR

SUPPLY AIR

RETURN AIROPTION

FRESH AIRFLOW

RELIEF AIRFLOW

POWER BURNER SUPPLY AIR

OPTION

CONTROLPANEL

PUFFDOOR

OPTION

COM

BUST

ION

PATH

FOUR PASSCOMBUSTION CHAMBER

U

V

3

L

RELIEF AIRDAMPER

M

FRESH AIRDAMPER

FILTERS

SPRING ISOLATOR

RETURN AIRDAMPER

M

T

P

NMIN.

CLEARANCE

M

Q

M U

H BLOWERS

W

UI

SUPPLY AIROPTION

SIDE VIEW

TOP VIEW

UU

4TYP.

Z

O

MOTOR

FLEXCONN.

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT.

HINGED DOORACCESS c/w

HANDLE

A A

SECTIONMIX BOX w/ RELIEF

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

V-BANK FILTER SECTION ALSO AVAILABLE, SEE PG. 29 FOR "A" DIMENSION

NOTES:

MODEL A B C D G H I K L M N O P Q T U V W

GIDM 20/25

GIDM 35/40

GIDM 45/55

GIDM 65/75

GIDM 85/100

GIDM 125/175

GIDM 200/250

GIDM 275/325

GIDM 350/400

GIDM 500/600

52

60

67

62

68

75

80

87

92

107 141

100

55

84

72

72

62

55

47

47

180

160

80

140

120

100

80

48

60

32

36

48

32

36

32

30

30

30

30

30

71

71

39

51

23

20

20

18

20

18

54

60

65

70

80

32

36

36

36

36

91

111

131

148

168

30

32

32

32

32 48

30

30

30

24

18

18

18

18

18

168

71

148

131

111

91

23

51

39

71

67

35

57

52

47

41

23

23

19

19

140

80

120

120

90

120

40

70

40

40

16

15

20

15

15

9

9

7

7

-

12

12

12

12

-

18

18

18

18

151

93

117

105

137

127

60

60

69

69

14

14

12

12

12

12

10

10

6

6 6

6

4

4

4

4

3

3

3

3 8

8

10

10

12

12

12

14

16

18

Z

2

2

17 12

11 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 29: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 27

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND MIX BOX WITH RELIEF

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

OPTIONSUPPLY AIR

NMIN.

CLEARANCE

I

I

U

U

K

G

A

C

D

B

OPTIONRETURN AIR

SUPPLY AIR

RETURN AIROPTION

FLOWRELIEF AIR FRESH AIR

FLOW

POWER BURNER SUPPLY AIR

OPTION

PUFFDOOR

CONTROLPANEL

OPTION

COM

BUST

ION

PATH

FOUR PASSCOMBUSTION CHAMBER

V

3

L

RELIEF AIRDAMPER

FILTERS

SPRING ISOLATOR

RETURN AIRDAMPER

M

FRESH AIRDAMPER

M T

MOTOR

BLOWERS

Q

MU UM

H

W

I U

SIDE VIEW

TOP VIEW

P

O

UU

4TYP.

Z HINGED DOORACCESS c/wHANDLE

FLEXCONN.

A SIZES 65/75 AND UP SPLIT FOR SHIPMENT.

SECTIONMIX BOX w/ RELIEF

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

V-BANK FILTER SECTION ALSO AVAILABLE, SEE PG. 30 FOR "A" DIMENSION

NOTES:

GIDMH 350/400

GIDMH 500/600

68

77

100

141

GIDMH 20/25

GIDMH 35/40

GIDMH 45/55

GIDMH 65/75

GIDMH 85/100

GIDMH 125/175

GIDMH 200/250

GIDMH 275/325

MODEL

5542

65

60

50

57

84

72

62

72

40

47

37

A

47

55

47

B

151

171

76

86216

196 36

36

32

42

30

48

184

204

111

131

D

42

54

38

42

38

60

66

71

110

156

176

132

110

78

90

62

C

30

32

36

36

30

30

30

30

G

2071

71

91

32

32

20

30

39

51

23

H

18

20

18

I

10118

35

30

18

24

167

147

101

123

18

18

18

K

69

81

53

L

140

14067

57

21 -

-

157

137

14

14

6

4

6

6

6

12

12

8

12

140

140

100

N

6023

52

47

35

41

80

19

23

19

M

40

40

40

12

18

18

O

11

9

9

69

117

127

93

105

P

60

69

60

Q

12

12

12

10

12

10

T U

6

6

16

18 2

2

103

4

4

4

4 12

14

12

12

3

3

V

3

10

8

W

8

Z

20

AA

17 12

27 12 11 1

2

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

6 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 30: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION AND MIX BOX WITHRELIEF AND RETURN AIR BLOWER SECTION

TITLE

28NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

I

T

OPTIONSUPPLY AIR

SUPPLY AIROPTION

I

I

PUFFDOOR

B

C

G

A

D

MOTOR

RETURN AIROPTION

OPTIONRETURN AIR

SIDE VIEW

RELIEF AIRFLOW

FRESH AIRFLOW

POWER BURNER

CONTROLPANEL

TOP VIEW

COM

BUST

ION

PATH

FOUR PASSCOMBUSTION CHAMBER

R

V

M

L

MU

FRESH AIRDAMPER

SPRING ISOLATOR

RETURN AIRDAMPER

RELIEF AIRDAMPER

M

SPRING ISOLATOR

FILTERS

UM

Q

BLOWER

U M

NMIN.

CLEARANCE

BLOWERS

U

U

K SUPPLY AIROPTION

P

H

U

U

WAAA

U

O

3

FLEXCONN.

MOTOR

HINGED DOORACCESS c/w

HANDLE (TYP)

4TYP.

Z

SECTIONRETURN AIR BLOWER

SECTIONMIX BOX w/ RELIEF

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

V-BANK FILTER SECTION ALSO AVAILABLE, SEE PG. 29 FOR "A" DIMENSION

A SPLIT FOR SHIPMENTNOTES:

7280GIDM 200/250

GIDM 500/600

GIDM 350/400

GIDM 275/325

92

107

87

100

141

84

GIDM 125/175

GIDM 85/100

GIDM 65/75

GIDM 45/55

GIDM 35/40

GIDM 20/25

MODEL

68

75

62

67

62

72

55

55

60

52

A

47

47

B

11130321113660120

168

148

131

80

70

65140

160

180 36

36

36

32

32

32

30

48

30

148

168

131

54

32

36

32

48

36

D

100

80

80

60

48

32

C

32

30

30

30

30

30

G

71

91

71

51

20

30

20

20

39

23

H

18

18

I

18

24

18

18

71

91

71

51

18

18

K

39

23

L

11712

12

1512047

120

120

140

57

67

52

20

16 -

- 137

157 14

14

6

6

18

18

18

18

12

12

90

N

35

41

23

23

80

70

40

19

19

M

40

40

9

9

15

15

7

7

O

93

105

69

69

P

60

60

Q

12

12

12

12

10

10

T U

124

6

4

6

18

16

14

2

2

4

4

3

3

12

12

10

10

3

3

V

8

8

W Z

109

137

127

127 122

117

75

100

68

72

R

61

17 12

11 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 31: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 29

GIDMH SERIES HORIZONTAL CONFIG. INDOOR UNIT GRAVITYVENTED c/w FLAT FILTER SECTION, MIX BOX WITH RELIEFAND RETURN AIR BLOWER SECTION

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

I

T

OPTIONSUPPLY AIR

SUPPLY AIROPTION

I

I

BA

C

D

RETURN AIROPTION

OPTIONRETURN AIR

TOP VIEW

FRESH AIRFLOW

SIDE VIEW

RELIEF AIRFLOW

POWER BURNER

PUFFDOOR

CONTROLPANEL

BLOWERS

COM

BUST

ION

PATH

FOUR PASSCOMBUSTION CHAMBER

R

M

V

M

3

L

U

FILTERS

RETURN AIRDAMPER

SPRINGISOLATOR

RELIEF AIRDAMPER

M

FRESH AIRDAMPER

SPRING ISOLATOR

M

Q

U M

BLOWERS

MOTOR

U

U

U

K

G

SUPPLY AIROPTION

H

NMIN.

CLEARANCE

U

P

141

100

7260GIDMH 200/250

GIDMH 275/325

GIDMH 500/600

GIDMH 350/400 68

77

65 84

GIDMH 125/175

GIDMH 85/100

GIDMH 65/75

GIDMH 45/55

GIDMH 35/40

GIDMH 20/25

MODEL

5547

50

57

42

62

72

55

40

37

A

47

47

B

147303236156 66 111

71

86

76

176

196

216

36

36

36

151

171

131

32

42

32

30

48

35

184

204

167

60

38

42

38

54

42

90

110

132

110

C

62

78

30

30

32

30

D

30

30

G

2051

71

91

71

20

30

20

39

23

H

18

18

I

8118

18

24

18

101

123

101

18

18

K

69

53

L

11747 140 6

6140

140

14057

67

52 20

21

-

-

137

151 14

14

6

40

40

40

80

60

N

100

23

35

41

23

M

19

19

11

18

18

12

9

9

O

6912

4

6

8

93

105

69

12

12

P

60

60

Q

12

12

12

12

10

10

T U

124

6

4

6

18

14

16

2

2

103

4

4

3

12

12

10

3

3

V

8

8

W Z

137

127

122127

117

109

100

75

72

68

61

R

U

W

U

O

FLEXCONN.

HINGED DOORACCESS c/w

HANDLE (TYP)

MOTOR

4TYP.Z

A SPLIT FOR SHIPMENT

SECTIONRETURN AIR BLOWER

SECTIONMIX BOX w/ RELIEF

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

NOTES:

V-BANK FILTER SECTION ALSO AVAILABLE, SEE PG. 30 FOR "A" DIMENSION

A A A

17 12

27 12 11 1

2

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

6 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 32: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOORUNIT GRAVITY VENTED WITH FLAT FILTER SECTION

TITLE

30NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

H

C

FLOW

FRES

H AI

R

E

SUPP

LY A

IROP

TION

F

PUFF

DOOR

T

L

MD

SPRI

NG

ISOL

ATOR

SIDE

VIE

W

FRES

H AI

RDA

MPE

R

C L

3

4

END

VIEW

BLO

WER

S

POW

ERBU

RNER

GRAV

ITY

VENT

CONN

ECTI

ON

N M

IN.

CLEA

RANC

E

GAS

CONN

ECTI

ON

K

A

CONT

ROL

PANE

L

SUPP

LY A

IROP

TION

COM

BUST

ION

PATH

W

A

K

B

U

GIDM

500

/600

GIDM

350

/400

GIDM

275

/325

GIDM

200

/250

GIDM

125

/175

GIDM

85/

100

GIDM

45/

55

GIDM

65/

75

GIDM

35/

40

GIDM

20/

25

140

9630

6584

67 8272

141

100

180

160

8070

117

107

4830

6250 6256

7272

38 3834

55 5547

3447

8048

120

100

6054

60 8048

36 3632

1882 9590

3024

70 7064

18 1818

3232

6418

3252

6512

013

1

1620

168

148

3232

8070

6757

140

120

7115 1515

111

91

9 97

51 7139

20 323020 2018

723

18

3548 6054

4741

36 3632

23 2319

80 120

9040 7040

3219

40

4

66

66

22

4 443 333

1410 1212 1210 14

16 18148 12 12128 1010V

U

H

CZ

G

FILT

ERS

U

HING

ED D

OOR

ACCE

SS c

/wHA

NDLE

HEAT

EXC

HANG

ERSE

CTIO

N

FILT

ER/B

LOW

ERSE

CTIO

N

A S

IZES

65/

75 A

ND U

P SP

LIT

FOR

SHIP

MEN

T

-10 10101015 1015 --

P

MOT

OR

MOD

EL

AB

CD

EF

GH

KL

MN

UV

ZT

WP

171 2

13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2

13 8 13 8 13 8 19 16 19 16 19 16 19 16

121 2

121 2

111 2

Page 33: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 31

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOORUNIT GRAVITY VENTED WITH ANGULAR FILTER SECTION

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

H

C

FLOW

FRES

H AI

R

E

SUPP

LY A

IROP

TION

F

PUFF

DOOR

T

L

MD

SPRI

NG

ISOL

ATOR

SIDE

VIE

W

FRES

H AI

RDA

MPE

R

3

4

END

VIEW

BLO

WER

S

POW

ERBU

RNER

GRAV

ITY

VENT

CONN

ECTI

ON

N M

IN.

CLEA

RANC

E

GAS

CONN

ECTI

ON

K

A

CONT

ROL

PANE

L

SUPP

LY A

IROP

TION

COM

BUST

ION

PATH

W

A

K

B

U

V

U

HC

Z

G

FILT

ERS

U

HING

ED D

OOR

ACCE

SS c

/wHA

NDLE

HEAT

EXC

HANG

ERSE

CTIO

N

FILT

ER/B

LOW

ERSE

CTIO

N

A S

IZES

65/

75 A

ND U

P SP

LIT

FOR

SHIP

MEN

T

P

GIDM

500

/600

GIDM

350

/400

GIDM

275

/325

GIDM

200

/250

GIDM

125

/175

GIDM

85/

100

GIDM

45/

55

GIDM

65/

75

MOD

EL

GIDM

35/

40

GIDM

20/

25

140

9630

6584

67 827214

110

018

016

08070

117

107

4830

6250 6256

7272

38 383455 5547

A 34

B 47

8048

120

100

6054

60 804836 3632

1882 9590

3024

70 706418 1818

C 32

D 32

E 64

F 18

3252

6512

013

1

162016

814

83232

80706757

140

120

7115 1515

111

91

9 9751 7139

20 323020 2018

G 7

H 23

K 18

3548 6054

4741

36 363223 2319

80 120

9040 7040

L 32

M 19

N 40

4

6666

22

4 443 33

UV 3

Z

1410 1212 1210T 1416 18148 12 12128 1010W

- --10 101010101515P

171 2

13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2

13 8 13 8 13 8 19 16 19 16 19 16 19 16

121 2

121 2

111 2

C L

Page 34: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOORUNIT GRAVITY VENTED WITH V-BANK FILTER SECTION

TITLE

32NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

H

C

FLOW

FRES

H AI

R

E

SUPP

LY A

IROP

TION

F

PUFF

DOOR

T

L

MD

SPRI

NG

ISOL

ATOR

SIDE

VIE

W

FRES

H AI

RDA

MPE

R

C L

FILT

ERS

3

4

END

VIEW

BLO

WER

S

POW

ERBU

RNER

GRAV

ITY

VENT

CONN

ECTI

ON

N M

IN.

CLEA

RANC

E

GAS

CONN

ECTI

ON

K

A

CONT

ROL

PANE

L

SUPP

LY A

IROP

TION

G

COM

BUST

ION

PATH

W

A

K

B

U

U

U

Z

C

HU

HING

ED D

OOR

ACCE

SS c

/wHA

NDLE

FILT

ER/B

LOW

ERSE

CTIO

N

SECT

ION

HEAT

EXC

HANG

ER

A S

IZES

65/

75 A

ND U

P SP

LIT

FOR

SHIP

MEN

T

GIDM

20/

25

GIDM

35/

40

MOD

EL

GIDM

65/

75GI

DM 4

5/55

GIDM

85/

100

GIDM

125

/175

GIDM

200

/250

GIDM

275

/325

GIDM

350

/400

GIDM

500

/600

6784

6530

9614

0

160

180

72 82

100

141

107

117

8070

4830

100

120

4734 3838 56 6250

62 727255 55

34AB 47

1864

3248

4880

6054

60 8036 36

8218

95903024

70 7018 18

C 32

D 32

E 64

F 18

1413

112

065

5232

57 67

148

168

162070 80

3232

14

120

140

66

19 19 2323 41 4735

3218

397 15

71 111

151591

9 951 71

4820

54 603230

363620 20

G 7

H 2332

K 18

L

1040

1212 12

80 90 120

7040

1040

MN

TU

144

22

1816

66

83

124

121244

10 103 3V 3

WZ

8

- --15 10 10101010P 15

P

171 2

13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2

13 8 13 8 13 8 19 16 19 16 19 16 19 16

121 2

121 2

111 2

Page 35: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 33

GIDM SERIES VERTICAL CONFIGURATION UPFLOWINDOOR UNIT GRAVITY VENTED WITH FLAT FILTERSECTION AND MIX BOX

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

COM

BUST

ION

PATH

END

VIEW

H

C BLO

WER

S

RETU

RN A

IRFL

OW

FRES

H AI

RFL

OW

E

T

M

D

KU

Q

RETU

RN A

IRDA

MPE

R

SIDE

VIE

W

FRES

H AI

RDA

MPE

R

3

4

POW

ERBU

RNER

GRAV

ITY

VENT

CONN

ECTI

ON

N M

IN.

CLEA

RANC

E

PUFF

DOOR

K

A

A

PANE

LCO

NTRO

L

GL F

SUPP

LY A

IROP

TION

SUPP

LY A

IROP

TION

GAS

CONN

ECTI

ON

W

A

SPRI

NG

ISOL

ATOR

K

B

U

FILT

ERS

GIDM

500

/600

GIDM

350

/400

GIDM

275

/325

GIDM

200

/250

GIDM

125

/175

GIDM

85/

100

GIDM

45/

55GI

DM 6

5/75

GIDM

35/

40

GIDM

20/

25

MOD

EL

15 1515 20 16

140

137

3065

8467

180

160

8272

141

100

151

161

70 80

30 48

120

100

8080604832

50 625638 3834

62 72 7247 5555

A 3447B

C

9991 111

136

129

9948 60543632 36

18 30241818 189 97

9132D

E

18FG 7

3252

6541

120

131

148

168

3232

8070

140

120

6757

4457

71 111

915139 7148

20 3230

6054

20 2018

36 3632

23HK 18

L 32

120

908035 474123 2319

40 7040

29 413929 2927

M 19

N 40

Q 27

4

66

66

22

4 443 33

TU

V 3

Z

14121210 1210 14

14 181612 121210108W 8

V

C

HU

U

Z

HING

ED D

OOR

ACCE

SS c

/wHA

NDLE

SECT

ION

FILT

ER/B

LOW

ER

SECT

ION

HEAT

EXC

HANG

ER

A S

IZES

65/

75 A

ND U

P SP

LIT

FOR

SHIP

MEN

T

- - -10 10 1015 101015P

P

C L

171 2

13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2

13 8 13 8 13 8 19 16 19 16 19 16 19 16

121 2

121 2

111 2

Page 36: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOORUNIT GRAVITY VENTED WITH ANGULAR FILTER SECTIONAND MIX BOX

TITLE

34NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

C L

COM

BUST

ION

PATH

END

VIEW

H

C BLO

WER

S

RETU

RN A

IRFL

OW

FRES

H AI

RFL

OW

E

T

M

D

KU

Q

RETU

RN A

IRDA

MPE

R

SIDE

VIE

W

FRES

H AI

RDA

MPE

R

3

4

POW

ERBU

RNER

GRAV

ITY

VENT

CONN

ECTI

ON

N M

IN.

CLEA

RANC

E

PUFF

DOOR

K

A

A

PANE

LCO

NTRO

L

GL F

SUPP

LY A

IROP

TION

SUPP

LY A

IROP

TION

GAS

CONN

ECTI

ON

W

A

SPRI

NG

ISOL

ATOR

K

B

U

FILT

ERS

GIDM

500

/600

GIDM

350

/400

GIDM

275

/325

GIDM

200

/250

GIDM

125

/175

GIDM

85/

100

GIDM

45/

55GI

DM 6

5/75

GIDM

35/

40

GIDM

20/

25

MOD

EL

15 1515 20 16

140

137

3065

8467

180

160

8272

141

100

151

161

70 80

30 48

120

100

8080604832

50 625638 3834

62 72 7247 5555

A 3447B

C

9991 111

136

129

99

48 60543632 36

18 30241818 189 97

9132D

E

18FG 7

3252

6541

120

131

148

168

3232

8070

140

120

6757

4457

71 111

915139 71

4820 3230

6054

20 2018

36 3632

23HK 18

L 32

120

908035 474123 2319

40 7040

29 413929 2927

M 19

N 40

Q 27

4

66

66

22

4 443 33

TU

V 3

Z

14121210 1210 14

14 181612 121210108W 8

V

C

HU

U

Z

HING

ED D

OOR

ACCE

SS c

/wHA

NDLE

SECT

ION

FILT

ER/B

LOW

ER

SECT

ION

HEAT

EXC

HANG

ER

A S

IZES

65/

75 A

ND U

P SP

LIT

FOR

SHIP

MEN

T

P

- - -10 10 1015 101015P

171 2

13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2

13 8 13 8 13 8 19 16 19 16 19 16 19 16

121 2

121 2

111 2

Page 37: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 35

GIDM SERIES VERTICAL CONFIGURATION UPFLOWINDOOR UNIT GRAVITY VENTED WITH V-BANK FILTERSECTION AND MIX BOX

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

COM

BUST

ION

PATH

END

VIEW

H

C BLO

WER

S

RETU

RN A

IRFL

OW

FRES

H AI

RFL

OW

E

T

M

D

KU

Q

RETU

RN A

IRDA

MPE

R

SIDE

VIE

W

FRES

H AI

RDA

MPE

R

3

FILT

ERS

4

POW

ERBU

RNER

GRAV

ITY

VENT

CONN

ECTI

ON

N M

IN.

CLEA

RANC

E

PUFF

DOOR

K

PANE

LCO

NTRO

L

GL F

SUPP

LY A

IROP

TION

SUPP

LY A

IROP

TION

GAS

CONN

ECTI

ON

W

A

SPRI

NG

ISOL

ATOR

K

B

U

U 6 6

MOD

EL

GIDM

20/

25

GIDM

35/

40

GIDM

65/

75GI

DM 4

5/55

GIDM

85/

100

GIDM

125

/175

GIDM

200

/250

GIDM

275

/325

GIDM

350

/400

GIDM

500

/600

7G 7 99 162015 1515

6784

6530

137

140

160

180

72 82

100

141

161

151

8070

4830

C 32 48 60 80 80 100

120

34 3838 56 625062 727255 5547

34AB 47

99 129

136

111

91 99

48 54 603632 36

18 24 301818 18

E 91

D 32

F 18

1413

112

041

6552

32

57 67

32 3216

8

148

70 80

57 44

120

140

14

19M 19 2323 41 4735

18 2020 30 322071 91 11

1

7139 51

48 54 6032 3636

18KH 23

32L

27 2929 39 412980 90 12

0

40 7040

121210 12

27Q

40N

10T

144

16 18

6 622

8 10 10 12 12124 4 43 33

8W

3VZ

V

U

HING

ED D

OOR

ACCE

SS c

/wHA

NDLE

(TYP

)

Z

A

C

HU

FILT

ER/B

LOW

ERSE

CTIO

N

SECT

ION

HEAT

EXC

HANG

ER

SECT

ION

MIX

BOX

A S

IZES

65/

75 A

ND U

P SP

LIT

FOR

SHIP

MEN

T

- --15 10 1015 101010P

A

P

C L

171 2

13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2

13 8 13 8 13 8 19 16 19 16 19 16 19 16

121 2

121 2

111 2

Page 38: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES VERTICAL CONFIGURATION UPFLOW INDOOR UNITGRAVITY VENTED WITH FLAT FILTER SECTION AND DX COIL

TITLE

36NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

COM

BUST

ION

PATH

END

VIEW

H

C

FRES

H AI

RFL

OW

T

K

L

Y

MD

DX C

OIL

(X x

Y)

DRAI

NPA

NSP

RING

IS

OLAT

OR

SIDE

VIE

W

FRES

H AI

RDA

MPE

R

FILT

ERS

3

4

BLO

WER

S

POW

ERBU

RNER

GRAV

ITY

VENT

CONN

ECTI

ON

N M

IN.

CLEA

RANC

E

GAS

CONN

ECTI

ON

PUFF

DOOR

A

PANE

LCO

NTRO

L

F

SUPP

LY A

IROP

TION

SUPP

LY A

IROP

TION

W

A

K

B

U

GIDM

20/

25

GIDM

35/

40

MOD

EL

GIDM

65/

75GI

DM 4

5/55

GIDM

85/

100

GIDM

125

/175

GIDM

200

/250

GIDM

275

/325

GIDM

350

/400

GIDM

500

/600

6784

6530

102

140

160

180

72 8210

014

112

213

78070

4830

100

120

4734 3838 56 6250

62 727255 55

34AB 47

1890

3248

4880

6054

60 8036 36

9818

102

102

3024

97 9218 18

C 32

D 32

E 82

F 18

1413

112

065

5232

57 6714

816

81620

70 803232

1412

014

066

19 19 2323 41 4735

3218

397 15

71 111

151591

9 951 71

4820

54 603230

363620 20

G 7

H 2332

K 18

L

1040

1212 12

80 90 120

7040

1040

MN

TU

144

221816

66

83

124

121244

10 103 3

ZV 3

W 8

125

165

145

65 105

8545 6533X 17

56 716139 514527 2723Y 23V

U

C

HU

FILT

ER/B

LOW

ER/C

OIL

SECT

ION

HEAT

EXC

HANG

ERSE

CTIO

N

HING

ED D

OOR

ACCE

SS c

/wHA

NDLE

E

Z

A S

IZES

65/

75 A

ND U

P SP

LIT

FOR

SHIP

MEN

T

G

- --10 101010 1015P 15

P

C L

171 2

13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2

13 8 13 8 13 8 19 16 19 16 19 16 19 16

121 2

121 2

111 2

Page 39: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 37

GIDM SERIES VERTICAL CONFIGURATION UPFLOWINDOOR UNIT GRAVITY VENTED WITH FLAT FILTERSECTION, DX COIL AND MIX BOX

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

C L

DFR

ESH

AIR

FLOW

SPRI

NG

ISOL

ATOR

3 M

FILT

ERS

FRES

H AI

RDA

MPE

R

BLO

WER

S

C

H

END

VIEW

COM

BUST

ION

PATH

B

K

U

GAS

CONN

ECTI

ON

N M

IN.

CLEA

RANC

E

GRAV

ITY

VENT

CONN

ECTI

ON

W

POW

ERBU

RNER

SUPP

LY A

IROP

TION

SIDE

VIE

W

L

T

K

CONT

ROL

PANE

L

PUFF

DOOR

GF

SUPP

LY A

IROP

TION

E

A

4

Y

DX C

OIL

(X x

Y)

DRAI

NPA

NQK

U

RETU

RN A

IRFL

OWR/A

DAM

PER

U 6 6

MOD

EL

GIDM

20/

25

GIDM

35/

40

GIDM

65/

75GI

DM 4

5/55

GIDM

85/

100

GIDM

125

/175

GIDM

200

/250

GIDM

275

/325

GIDM

350

/400

GIDM

500

/600

7G 7 99 162015 1515

6784

6530

143

140

160

180

72 8210

014

118

116

68070

4830

C 32 48 60 80 80 100

120

34 3838 56 625062 727255 5547

34AB 47

121

141

143

127

117

126

48 54 603632 36

18 24 301818 18

E 109

D 32

F 18

1413

112

041

6552

32

57 6732 32

168

148

70 8057 44

120

140

14

19M 19 2323 41 4735

18 2020 30 322071 91 11

1

7139 51

48 54 6032 3636

18KH 23

32L

27 2929 39 412980 90 12

0

40 7040

121210 12

27Q

40N

10T

144

16 186 6

22

8 10 10 12 12124 4 43 33

8W

3VZ

125

165

145

65 105

8565453317XY 39 452723 2723 56 716151

V

U

C

HU

Z

FILT

ER/C

OIL/

BLOW

ERSE

CTIO

N

HEAT

EXC

HANG

ERSE

CTIO

N

MIX

BOX

SECT

ION

HING

ED D

OOR

ACCE

SS c

/wHA

NDLE

(TYP

)

AA

SIZ

ES 6

5/75

AND

UP

SPLI

T SH

IPM

ENT

- --10 10101015 1015P

A

P

171 2

13 841 2 41 2 41 2 41 2 41 2 41 2 41 2 41 2

13 8 13 8 13 8 19 16 19 16 19 16 19 16

121 2

121 2

111 2

Page 40: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM SERIES HORIZONTAL CONFIG. OUTDOOR UNITGRAVITY VENTED c/w FLAT FILTER SECTION AND MIXBOX WITH RELIEF AND RETURN AIR BLOWER SECTION

TITLE

38NOTE ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT

NOTICE AND TO MANUFACTURING TOLERANCES

SIDE VIEW

TOP VIEW

GRAVITY VENT CAP

U

H

P

U

K

G

I

A

C

D

B

RETURN AIROPTION

RETURN AIROPTION

SUPPLY AIR

POWERBURNER

SUPPLY AIROPTION

OPTION

CONTROLPANEL

MOTOR

FRESH AIRFLOW

RELIEF AIRFLOW

COM

BUST

ION

PATH

FOUR PASSCOMBUSTION

CHAMBERM

R

V

3

M

L

U

SPRING ISOLATOR

4

Y

BLOWERS

FILTERS

J(X

x Y)

RETURN AI

R DAM

PER

XUINLETHOOD

FRESH AIRDAMPER

Q

BLOWER

RELIEF AIRDAMPER

NMIN.

CLEARANCE

I

OPTIONSUPPLY AIR

O

M

19

1923

23

41

35

52

67

57

47

7275GIDM 125/175

GIDM 275/325

GIDM 350/400

GIDM 500/600

GIDM 200/250

107

92

80

87

141

100

84

72

A SPLIT FOR SHIPMENT

MODEL

GIDM 20/25

GIDM 35/40GIDM 45/55

GIDM 65/75GIDM 85/100 68

62

6760

6255

4755

52

A

47

B

9153309132100 54

180

160

140

120

70

80

65

60

36

36

36

36

148

168

131

111

64

59

69

7932

32

32

32 131

168

148

111

8080

4860

4836

3236

C

32 32

D

3030

3030

7171

5139

30

G

23

H

28

2831

3931

2020

2018

18

I J

3951

7171

L

23

109 12691590 12

16

15

140

120

120

120

20

-

-

12

12

102

90

73

79

127

122

137

117

14

14

6

6

15

4040

7080

40

N

9

97

1218

1818

7

O

18

P

5159

4539

10075

6872

29

Q

61

R

1212

1012

10

T U

124

6

6

4

4

16

18

14

12

2

2

43

33

1210

810

V

3

W

8

Z

70

90

78

64

60

4250

20

3630

X

57

72

62

46

52

2840

24

2824

Y

U

30

48

30

24

30

1818

18

1818

K

U

XUJ

RELIEFHOOD

4TYP.

Z

MOTOR

FLEXCONN.

HINGED DOORACCESS c/w

HANDLE (TYP)

DRAIN PAN PROVIDEDIN W.H. AREA c/w

DRAIN HOLE IN BTM.

A

A A

SECTIONRETURN AIR BLOWER MIX BOX w/ RELIEF

SECTIONBLOWER/FILTER

SECTIONHEAT EXCHANGER

SECTION

FOR DIMENSIONS OF OTHER COMPONENTS (i.e. V-BANK FILTER SECTION)

NOTES:

SEE INDOOR UNIT DRAWINGS

17 12

11 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 41: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

TITLE

NOTEINDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD. 39

GIDMH SERIES HORIZONTAL CONFIG. OUTDOOR UNITGRAVITY VENTED c/w FLAT FILTER SECTION, MIX BOXWITH RELIEF AND RETURN AIR BLOWER SECTION

ALL DIMENSIONS ARE SUBJECT TO CHANGE WITHOUTNOTICE AND TO MANUFACTURING TOLERANCES

TOP VIEW

SIDE VIEW

GRAVITY VENT CAP

U

H

SUPPLY AIR

U

K

NMIN.

CLEARANCE

G

4TYP

D

C

I

A B

RETURN AIROPTION

RETURN AIROPTION

OPTION

FRESH AIRFLOW

POWER BURNER

OPTION

CONTROLPANEL

FLOWRELIEF AIR

COM

BUST

ION

PATH

SUPPLY AIR

FOUR PASSCOMBUSTION

CHAMBER

R

V

M

3

L

U M

JU

SPRINGISOLATOR

FILTERS

4

MOTORY

SPRINGISOLATOR

Q

RETU

RN A

IR D

AMPE

R

X

AA A

FRESH AIRDAMPER

(X x

Y)

RELIEF AIRDAMPER

MOTOR

BLOWERS

I

OPTIONSUPPLY AIR

P

19

19

M

23

41

35

23

52

67

57

47

GIDMH 125/175

GIDMH 350/400

GIDMH 500/600

GIDMH 275/325

GIDMH 200/250

77 141

65

68

57

60

84

100

72

72

MODEL

GIDMH 20/25

GIDMH 35/40

GIDMH 45/55

GIDMH 65/75

GIDMH 85/100

42

50

40

47

55

62

47

55

A

37

B

47

216 86

176

196

132

156

71

76

60

66

17136

36

36

36

32

131

151

111

91 24

35

48

30

30

42

32

32

32

30

204

123

167

184

147

110

110

78

90

42

54

38

42

62

C

38

D

30

30

30

30

71

71

51

39

G

30

H

23

18

18

18

18

18

20

20

20

18

18

K

69

101

101

81

L

53

91

18

21

20

140

100

140

140

140

-

-

6

6

6

127102

73

79

69

127

122

117

113

614

14

12

12

18

11

60

80

40

40

40

N

12

12

9

4

8

12

O

9

P

51

59

45

39

101

83

82

69

Q

29

R

69

12

12

12

10

T

10

U

4

186

12

16

14

12

4

6

4

2

2

10

12

10

4

3

3

3 8

V

3

W

8

ZI

79

39

69

64

53

59

31

31

28

28

J X

78

46

68

63

52

58

50

36

30

20

78

46

68

63

58

52

36

34

30

30

Y

U

O

Z

BLOWERS

XU

FLEXCONN.

J

DRAIN PAN PROVIDEDIN W.H. AREA c/w

DRAIN HOLE IN BTM.

HINGED DOORACCESS c/w

HANDLE (TYP)

RELIEFHOOD

INLETHOOD

A SPLIT FOR SHIPMENT

MIX BOX w/ RELIEFSECTIONSECTION

RETURN AIR BLOWERSECTION

FILTER/BLOWER HEAT EXCHANGERSECTION

FOR DIMENSIONS OF OTHER COMPONENTS (i.e. V-BANK FILTER SECTION) SEE INDOOR UNIT DRAWINGS

NOTES:

17 12

27 12 11 1

2

4 12

4 12

4 12

4 12

4 12

4 12

4 12

4 12

6 12

12 12

1 38

1 38

1 38

1 38

1 916

1 916

1 916

1 916

Page 42: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

GIDM/GIDMH MODULATING MANIFOLD ARRANGEMENTFOR CGA, ETL, F.M., AND I.R.I. APPROVAL

TITLE

40

LEGEND

1

REF.

3

4

5

6

8

9

2

DESCRIPTION

UNION CONNECTION

PILOT MANUAL SHUT-OFF VALVE

PILOT PRESSURE REGULATOR

PILOT AUTOMATIC SAFETY SHUT-OFF VALVE

PILOT MANUAL FIRING VALVE

MAIN BURNER GAS PRESSURE REGULATOR

MAIN BURNER TEST FIRING VALVE

MAIN BURNER ORIFICE

1/8" TEST PORT

7 MAIN BURNER AUTO SAFETY SHUT-OFF VALVE

10

11

MODULATING GAS VALVE

CGA APPROVED GAS MANIFOLD

ETL APPROVED GAS MANIFOLD

I.R.I. APPROVED GAS MANIFOLD

F.M. APPROVED GAS MANIFOLD

LOW GAS PRESSURE SWITCH

HIGH GAS PRESSURE SWITCH

AUXILLARY SAFETY SHUT OFF VALVE

NORMALLY OPEN VENT VALVE

VENT LIMITER

MAIN MANUAL VALVE

17

16

14

15

13

12

NOTE(S):1. ON MANIFOLD SIZES 1 1/4" ON UP ITEM 6 MUST BE VENTED TO THE ATMOSPHERE

3. ON MANIFOLD SIZES 1 1/4" ON UP ITEM 6 MUST BE VENTED TO THE ATMOSPHERE2. ITEM 15 ON UNITS ABOVE 400,000 BTU ONLY (MOTORIZED)1. ITEM 13 AND 14 ON UNITS OVER 2,475,000 BTU ONLY.

NOTE(S):

1. ON MANIFOLD SIZES 1 1/4" ON UP ITEM 6 MUST BE VENTED TO THE ATMOSPHERENOTE(S):

1. ON MANIFOLD SIZES 1 1/4" ON UP ITEM 6 MUST BE VENTED TO THE ATMOSPHERENOTE(S):

2. ITEMS 13 AND 14 ABOVE 400,000 BTU ONLY3. ITEM 16 ABOVE 1,000,000 BTU ONLY

Page 43: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

Type and Description

Furnish an I.C.E GIDM Model indirect fired self-contained make-up air unit in accordance with the following specifications. The unit shall be ETL andC.G.A certified

The heater shall be designed to ensure a minimum efficiency of 80% at full firing rate. The heat exchanger and blower shall be constructed so they caneasily be disassembled and reassembled in the field if necessary. The unit shall be equipped to operate from a single point power connection. Theheater shall be flame tested before shipment and a detailed flame test report shall be kept on file by the manufacturer. Factory testing shall be confirmedwith a combustion analyzer and flow meter. The heater shall be shipped completely factory assembled and wired including all prepiped manifoldcomponents and fuses, ready for immediate power and fuel connections.

Casing

The unit exterior casing shall be heavy gauge G90 rated bonderized steel. Unit roofs shall be sloped for water drain off and feature standing seamconstruction. The entire unit casing shall be insulated with 2 in. thick 3-lb. Fiberglass insulation with hard neoprene backing in a sandwich wall fashion.The unit exterior shall be finished with industrial catalyzed epoxy paint. An integral welded iron channel frame shall support the unit casing. Formedsheet metal bases are unacceptable. The structural iron frame shall be sandblasted, primed and finished with industrial catalyzed epoxy paint.

Blower/Motor Section

The fan section and motor assembly shall be constructed in accordance with the requirements of the Air Moving and Conditioning Association (AMCA).The assembly shall be designed to house the fan(s), bearings, motor, and v-belts which shall be selected for at least 50% above the rated motorcapacity. The fan(s) and motor shall be mounted on a welded unitary base made of angle iron frame. The frame shall be sandblasted, primed andfinished with industrial catalyzed epoxy paint. The unitary base shall be provided with seismic spring vibration isolation. The blower section shall have ahinged access door to allow easy maintenance of filters and belts. The NEMA T-Frame motor shall be mounted on an adjustable base located within thefan section. The blower wheel shall be statically and dynamically balanced, and mounted on a turned, ground and polished shaft with rigid bearingsupports. The shaft shall be designed with a maximum operating speed not exceeding 75% of the first critical speed. The bearings shall be split taperlock ball bearing type L20 minimum life of 100,000 hours.

Heat Exchanger

The heat exchanger shall be of four pass design with a primary combustion chamber and multi-tube secondary. Internal turbulators or other fluerestrictor to boost efficiency are unacceptable. The entire primary heat transfer surface shall be constructed of Type 409 Series stainless steel, and shallbe cooled in its entirety by the air to be heated. The Secondary heat transfer surface shall also be constructed from Type 409 Series stainless steel. The stainless steel tubes shall be continuously welded into the secondary front and rear header tube sheets to ensure an airtight seal. Mechanicallyswedging the tubes are unacceptable. All heat transfer surfaces, including headers and the front collector box, shall be inside the casing and in theairstream. The construction of the heat exchanger shall permit free, unrestricted lateral, vertical, and peripheral expansion during the heating and coolingcycle without damage or strain to any part. The heat exchanger shall be designed to prevent contamination of heated air with the products ofcombustion. A spring loaded pressure relief door with glass view port shall be provided. The entire heater casing shall be lined with a 22 gauge liner.

Burner

The heater shall have of a power type 409 stainless steel burner, with integral combustion air blower and motor; combustion air proving switch,removable pilot assembly and positive pilot combustion air supply. The combustion air damper shall be interlocked with the main gas valve to insure a proper air/gas mixture. A solid state programmable safeguard relay with UV Scanner and purge card shall continuously monitor main and pilot flame. The main and pilot valve train to the burner shall be completely factory prepiped. This assembly shall be wired and include the following minimumcomponents; main and automatic shut off valves and adequate unions and test ports for service. A 6,000 volt transformer shall accomplish ignition ofpilot flame. The unit shall be suitable for natural gas and designed and certified by ETL and C.G.A to provide full gas modulation. Depending on theburner selection, turndown from 100% to 7% of output are achievable.

Electrical Control Equipment

Electrical assembly and components shall be in strict accordance with the latest provisions and requirements of the Nation Electric Code. Controlcabinet shall be designed and constructed to ETL specifications. A dead front safety disconnect switch shall be mounted on the control enclosure door.Electrical cabinets shall be NEMA 12. The cabinets shall be located in a weather proof cabinet. Provisions for service padlocking shall be provided. Thefollowing items shall be located within the electrical enclosure: fuses, starters, control relays, timing and holding relays, resistors and numbered terminalstrips. All components shall be labeled and cross referenced to control and field wiring diagrams. The control circuit shall be 110V, single phase. Wiringshall be neatly run in “PANDUIT” wiring duct. Low and/or line voltage thermostats shall be furnished shipped loose for installation by others. Unit shallbe equipped with automatic low limit freeze protection with bypass timer. Unit will feature a convenience outlet with separate disconnect, circuit breakerprotection and supply transformer. Temperature control shall consist of a solid state PID loop with adjustable setpoints. A discharge temperature sensorshall be wired in series-parallel to room sensor. The temperature control system may be controlled by DDC at any time during operation. DDC systemmay take control of blower/burner/dampers and modulating gas valve.

Remote Control Panels

Remote NEMA 12 locking stainless steel control panels shall be equipped with summer or winter switch and blower on, burner on, flame failure andloaded filter lights. A remote adjustment potentiometer shall control damper positioning. A LCD display shall provide system temperature and setpoints.

Mix Box and Filter Section

A mix box with fresh air and return air dampers shall be provided. The dampers are to be aluminum airfoil low leak type with seals. The dampers are tobe inset into 22 gauge steel mix box liners. The dampers shall be equipped with modulation actuators.

The blower section shall include a motor operated outside air intake sized for 100% outside air. The filters shall be 2" pleated throwaway type withminimum of 85% arrestance and 30% dust. Filter access shall be through a latched and gasketed access doors located on both sides of the unit.

Typical Specification for a GIDM Unit INDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD.

Page 44: GIDM Indirect-Fired Heating and Ventilating Unitsice-us.com/site/1853ice_/GIDM_New_Catalogue.pdf · unit should be selected for this application. 18,000 CFM at 0.5" W.C is determined

BMADirect Gas-Fired makeup Air Units

OSDDirect Fired Makeup

Air/Curing Units

IMAIndustrial

Gas-Fired Units

GIDMIndirect

Gas-Fired Units

h 100% makeup air and 80/20 units

h Stainless steel burner

h DX or evaporative cooling section option

h 30:1 turndown ratio

h Recirculating & Dual Air Dual Temperature Sequence

h Exceptional spray booth control packages using PLCs

h Booth balancing option with variable frequency drive on exhaust

h Premium makeup air/curing units for the refinishing industry

h 100% makeup air & 80/20 units

h Suitable for any automotive or high-end industrial applications

h Backward inclined blowers standard on sizes 140 and up

h Four-pass drum and tube industrial grade stainless steel heat exchanger

h Industrial quality forced draft power burner

h High efficiency (80%) and excellent durability

h JIC wiring available for the automotive industry

HTDMHigh Turndown

Indirect-Fired Units

MTIIndirect

Gas-Fired Units

ACAir Turnover Units

CUSTOMBUILTUNITS

h Stainless steel two-pass drum and tube heat exchanger with forced draft power burner

h Best turndown ratio for power burners in the industry (Up to 60:1)

h Inputs of 200, 400, 600, 1000 & 1500 MBH

h Up to 85% (minimum efficiency)

h Indoor or Outdoor packaged indirect-fired heating systems

h Stainless steel heat exchanger suitable for 100% outside air

h Excellent temperature control through brand name components

h Wide variety of configuration options

h Superior serviceability through design and simplistic operation

h Vertical air turnover heating systems

h An effective and economical solution to heating, ventilating or conditioning large spaces

h Four-pass indirect-fired heat exchanger

h Optional A-coil cooling section

h ICE has the capability to build a wide variety ofcustom-built units for any type of commercial orindustrial application

h Specializing in heat recovery and custom air handler with heating or cooling coils

INDUSTRIAL COMMERCIAL

EQUIPMENT MANUFACTURING LTD.

ICE MANUFACTURING LTD.

51 Aikins Street

Winnipeg, Manitoba

Canada R2W 4E3

Tel: (204) 586-8565

Fax: (204) 589-7682

www.ice-ww.com

ICE (U.S.) INC.

Industrial Park

Bolivar, Tennessee

United States 38008

Tel: (731) 658-7000

Fax: (731) 658-3090

www.ice-us.com

Printed in Canada

EXCELLENCE THROUGH

PROVEN PERFORMANCE