gl cc mix design 071110

55

Upload: hambadah

Post on 18-Apr-2015

65 views

Category:

Documents


0 download

DESCRIPTION

concrete

TRANSCRIPT

Page 1: Gl Cc Mix Design 071110
Page 2: Gl Cc Mix Design 071110

2

CEMENT CONCRETE MIX DESIGN

by

K. RAMESH

Research Officer,Engineering Materials Laboratory,

A.P. Engineering Research Laboratories,Himayatsagar, HYDERABAD-500030.

Page 3: Gl Cc Mix Design 071110

3

Cement Concrete Mix Design means, determination of the proportion of the concrete ingredients i.e. Cement, Water, Fine Aggregate,Coarse Aggregate which would produce concrete possessing specified properties such as workability, strength and durability with maximum overall economy.

Page 4: Gl Cc Mix Design 071110

4

Methods of Concrete Mix Design

• I.S. Method

• British Method

• A.C.I. Method etc.

Page 5: Gl Cc Mix Design 071110

5

These Methods are based on two basic assumptions

Compressive Strength of Concrete is governed by its Water-Cement Ratio

Workability of Concrete is governed by its Water Content

Page 6: Gl Cc Mix Design 071110

6

Data required for concrete mix design

1. Grade of Concrete

Eg: RCC-M30-A20

2. Slump required in mm

Eg: 25 – 75 mm

3. Degree of Site Control

Eg: Good

4. Type of Exposure

Eg: Moderate

5. Grade of Cement

Eg: OPC 43 Grade

Page 7: Gl Cc Mix Design 071110

7

Placing Conditions Degree of Workability Slump (mm)

1 2 3

Blinding Concrete; Shallow Sections; Pavements using pavers

Very Low See 7.1.1

Mass Concrete; Lightly reinforced sections in Slabs, Beams, Walls, Columns; Floors; Hand placed Pavements; Canal lining; Strip Footings

Low 25-75

Heavily reinforced sections in Slabs,Beams, Walls, Columns;Slip form work; Pumped Concrete.

Medium 50-100

Trench fill; In-Situ Piling; Tremie Concrete High 100-150

Page 8: Gl Cc Mix Design 071110

8

Good

Site control having proper storage of cement; weigh batching of all materials; Controlled addition of water, regular checking of all materials, aggregate grading and moisture content; And periodical checking of workability and strength.

Fair Site control having deviation from the above.

Page 9: Gl Cc Mix Design 071110

9

Sl.No.

Environment Exposure Conditions

1 2 3

i) MildConcrete surfaces protected against weather or aggressive conditions, except those situated in coastal area.

ii) Moderate

Concrete surfaces sheltered from severe rain or freezing whilst wet.Concrete exposed to condensation and rain.Concrete continuously under water.Concrete in contact or buried under non-aggressive soil/ground water.Concrete surfaces sheltered from saturated salt air in coastal area.

iii) Severe

Concrete surfaces exposed to severe rain, alternate wetting and drying or occasional freezing whilst wet or severe condensation.Concrete completely immersed in sea water.Concrete exposed to coastal environment.

iv) Very Severe

Concrete exposed to sea water spray, corrosive fumes or severe freezing conditions whilst wet.Concrete in contact with or buried under aggressive sub-soil/ground water.

v) ExtremeSurface of members in tidal zone.Members in direct contact with liquid/solid aggressive chemicals.

Page 10: Gl Cc Mix Design 071110

10

Approximate Quantity of Materials required for concrete mix design

1. Cement : 200 Kg.

2. Fine Aggregate : 240 Kg.

3. Coarse Aggregate : 180 Kg. (20 mm)

180 Kg. (10 mm)

Page 11: Gl Cc Mix Design 071110

11

STEPS INVOLVED IN CONCRETE MIX DESIGN

Step I:- Determine the physical properties of concrete ingredients.

I. CEMENT (OPC 43 Grade)

Sl.No.

Particulars of Test Result SpecificationsAs per IS:8112-1976

1 Standard consistency (% by weight)

25.6

2 Setting Time in minutesa) Initialb) Final

95210

30 Minimum600 Maximum

3 Compressive Strength in N/sq.mm at the age of a) 3 days

b) 7 days c) 28 days

243546

23 Minimum33 Minimum43 Minimum

4 Specific Gravity 3.00

5 Fineness in Sq.m/Kg 337 225 Minimum

Page 12: Gl Cc Mix Design 071110

12

Sieve Size % Passing Specifications for Zone–IIAs per IS:383-1970

10.0 mm 100 100

4.75 mm 100 90-100

2.36 mm 98 75-100

1.18 mm 65 55-90

600 micron 42 35-59

300 micron 8 8-30

150 micron 0 0-10

II. FINE AGGREGATE

1. Sieve Analysis

2. Specific Gravity : 2.60

3. Unit Weight in Kg/Cu.ma) Loose : 1460b) Rodded : 1580

4. Materials Finer than 75 micron : 1.00 3 Max(% by weight)

Page 13: Gl Cc Mix Design 071110

13

Sieve Size % Passing Specifications As per IS:383-1970

Graded Single Sized40.00mm 100 100 10020.00mm 90 95-100 85-10010.00mm 3 25-55 0-204.75mm 0 0-10 0-5

III. 20.0mm COARSE AGGREGATE

1. Sieve Analysis

2. Specific Gravity : 2.65

3. Unit Weight in Kg/Cu.ma) Loose : 1467b) Rodded : 1633

Page 14: Gl Cc Mix Design 071110

14

Sl.No.

Particulars of Test Result SpecificationsAs per IS: 383-1970

1 Crushing Value in % 28 30 MaximumFor wearing surfaces

45 MaximumFor other concrete

2 Impact Value in % 24 30 MaximumFor wearing surfaces

45 MaximumFor other concrete

3 Los Angeles Abrasion Value in %

30 30 MaximumFor wearing surfaces

50 MaximumFor other concrete

IV. MECHANICAL PROPERTIES

Page 15: Gl Cc Mix Design 071110

15

Sieve Size % Passing Specifications As per IS:383-1970

Graded Single Sized

12.50mm 100 – 100

10.00mm 85 – 85-100

4.75mm 19 – 0-20

2.36mm 0 – 0-5

V. 10.0mm COARSE AGGREGATE

1. Sieve Analysis

2. Unit Weight in Kg/Cu.ma) Loose : 1427b) Rodded : 1587

Page 16: Gl Cc Mix Design 071110

16

VI. BLENDING OF COARSE AGGREGATE:

Sieve size

(mm)

IS:383-1970Specifications (Graded)

% Passing

20 mm 10 mm 60%+40% 50%+50%

40 100 100 100 100 100

20 95-100 90 100 94 95

10 25-55 3 85 40 44

4.75 0-10 0 19 7 10

Page 17: Gl Cc Mix Design 071110

17

Step II:- Compute Target Mean Compressive Strength:

Fck = fck + t * S

Fck = Target Mean Compressive Strength at 28 days in N/Sq.mm

fck = Characteristic Compressive Strength at 28 days in

N/Sq.mm

S = Standard Deviation in N/Sq.mm

t = A Statistic, depending on accepeted proportion of low results. = 1.65 for 1 in 20 accepted proportion of low results

Page 18: Gl Cc Mix Design 071110

18

Values of t

Accepted proportion of low results

t

1 in 5, 20% 0.84

1 in 10, 10% 1.28

1 in 15, 6.7% 1.50

1 in 20, 5% 1.65

1in 40, 2.5% 1.86

1 in 100, 1% 2.33

Page 19: Gl Cc Mix Design 071110

19

Assumed Standard Deviation (Table 8, IS:456-2000)

Grade of Concrete

Assumed Standard Deviation(N/Sq.mm)

Good Site Control Fair Site Control

M10, M15 3.5 4.5

M20, M25 4.0 5.0

M30, M35M,40,M45

M505.0 6.0

Page 20: Gl Cc Mix Design 071110

20

Step III:- Select the Water-Cement ratio of trial mix from experience

S.No.

Concrete Grade

Minimum expected W/C

1 M10 0.9

2 M15 0.7

3 M20 0.55

4 M25 0.50

5 M30 0.45

6 M35 0.40

7 M40 0.35

8 M45 0.30

Page 21: Gl Cc Mix Design 071110

21

Step IV:- Select the water content per cubic metre of concrete from table2 of I.S: 10262-2009.

Maximum size of Aggregate

(mm)

Water Content per cubic metre of

concrete(Kg)

10 208

20 186

40 165

Page 22: Gl Cc Mix Design 071110

22

Approximate water content (Kg) per cubic metre of concrete (Table 32, SP:23-1982)

Slump(mm)

Maximum Size of Aggregate

(mm)

10 20 40

30-50 205 185 160

80-100 225 200 175

150-180 240 210 185

Page 23: Gl Cc Mix Design 071110

23

Volume of Coarse Aggregate per Unit Volume of Total Aggregate (Table 3, IS:10262-2009)

Maximum Size of Aggregate(mm)

Volume of Coarse Aggregate per Unit Volume of Total Aggregate

Zone IV Zone III Zone II Zone I

10 0.50 0.48 0.46 0.44

20 0.66 0.64 0.62 0.60

40 0.75 0.73 0.71 0.69

Page 24: Gl Cc Mix Design 071110

24

Page 25: Gl Cc Mix Design 071110

25

Step V:- Compute the quantity of cement as follows.

Water Cement = ------------- W/C Ratio

= 185 / 0.45 = 411 Kg.

Page 26: Gl Cc Mix Design 071110

26

Step VI:- Then we find the quantities of Fine & Coarse aggregate by absolute volume method.

V = (W+C/Sc+(1/p) * (fa/Sfa)) * (1/1000) - (Eq.1) andV = (W+C/Sc+(1/(1-p)) * (ca/Sca)) * (1/1000) - (Eq.2)

Where

V = Absolute volume of fresh concrete = 1 m3

W = Mass of Water (Kg) per m3 of concrete C = Mass of Cement (Kg) per m3 of concrete p = Percentage of fine aggregate. fa = Mass of fine aggregate ca = Mass of coarse aggregate Sc = Specific gravity of cement. Sfa = Specific gravity of fine aggregate. Sca = Specific gravity of coarse aggregate.

Page 27: Gl Cc Mix Design 071110

27

Substituting the values in Eq(1), we get

1000 = 185 + 411/3.0 + (1/0.36) * fa /2.6)

= 185 + 137 + fa/0.936

= 322 + fa/0.936

fa = (1000 – 322) * 0.936

= 678 * 0.936

= 635 Kg.

Page 28: Gl Cc Mix Design 071110

28

Substituting the values in Eq(2), we get

1000 = 185 + 411/3.0 + (1/0.64) * ca /2.65)

= 185 + 137 + ca/1.696

= 322 + ca/1.696

ca = (1000 – 322) * 1.696

= 678 * 1.696

= 1150 Kg.

Page 29: Gl Cc Mix Design 071110

29

So the mix proportion works out to be

W : C : fa : ca

= 185 : 411 : 635 : 1150

= 0.45 : 1 : 1.55 : 2.80

This mix will be considered as Trial Mix No.2

Page 30: Gl Cc Mix Design 071110

30

Step VII:- Make slump trials to find out the actual weight of water to get required slump. Make corrections to the water content & %FA, if required.

Step VIII:- Compute 2 more trial mixes with W/C ratios as 0.40 & 0.50, taking %FA as 34% and 38% respectively.

Page 31: Gl Cc Mix Design 071110

31

Trial Mix No. 1:-

Cement = 185 / 0.4 = 462.5 Kg.

Substituting the values in Eq(1), we get

1000 = 185 + 462.5/3.0 + (1/0.34) * fa /2.6)

fa = 584 Kg.

Substituting the values in Eq(2), we get

1000 = 185 + 462.5/3.0 + (1/0.66) * ca /2.65)

ca = 1156 Kg.

So the mix proportion works out to be

W : C : fa : ca

= 185 : 462.5 : 584 : 1156

= 0.4 : 1 : 1.26 : 2.50

Page 32: Gl Cc Mix Design 071110

32

Trial Mix No. 3:-

Cement = 185 / 0.5 = 370 Kg.

Substituting the values in Eq(1), we get

1000 = 185 + 370/3.0 + (1/0.38) * fa /2.6)

fa = 683 Kg.

Substituting the values in Eq(2), we get

1000 = 185 + 370/3.0 + (1/0.62) * ca /2.65)

ca = 1136 Kg.

So the mix proportion works out to be

W : C : fa : ca

= 185 : 370 : 683 : 1136

= 0.5 : 1 : 1.85 : 3.07

Page 33: Gl Cc Mix Design 071110

33

Step IX:- Cast atleast 3 cubes for each trial mix.

Step X:- Test the cubes for compressive strength at 28 days.

Page 34: Gl Cc Mix Design 071110

34

28 Days Compressive Strengths of Trial Mixes

W/C Ratio

C/W RatioCompressive

Strength (Kg/Cm2)

0.40 2.50 457

0.45 2.22 420

0.50 2.00 360

Page 35: Gl Cc Mix Design 071110

35

Step XI:- Draw a graph between compressive strength Vs C/W Ratio.

Page 36: Gl Cc Mix Design 071110

36

Page 37: Gl Cc Mix Design 071110

37

Step XII:- From the graph, find the W/C ratio for the required target mean compressive strength.

Step XIII:- Calculate the mix proportions corresponding to the W/C ratio, obtained from the graph.

Page 38: Gl Cc Mix Design 071110

38

Final Mix:-From the graph, for a target strength of 390 Kg/Cm2, W/C ratio = 0.47Cement = 185 / 0.47 = 394 Kg.Substituting the values in Eq(1), we get1000 = 185 + 394/3.0 + (1/0.38) * fa /2.6)fa = 675 Kg. Substituting the values in Eq(2), we get1000 = 185 + 394/3.0 + (1/0.62) * ca /2.65)ca = 1123 Kg. So the mix proportion works out to beW : C : fa : ca = 185 : 394 : 675 : 1123= 0.47 : 1 : 1.71 : 2.85

Page 39: Gl Cc Mix Design 071110

39

Step XIV:- Check the cement content & W/C ratio against the limiting values given in Table-5 of I.S: 456-2000 for given type of exposure & type of Concrete.

Page 40: Gl Cc Mix Design 071110

40

Table-5 Minimum Cement content Maximum Water-Cement ratio and Minimum Grade of Concrete for different exposures with normal weight of aggregate of 20mm nominal maximum size.

Sl.No.

Exposure

Plain Concrete Reinforced Concrete

Minimum Cement Content

kg/m3

Maximum Free

Water Cement Ratio

Minimum Grade of Concrete

Minimum Cement Content

kg/m3

Maximum Free

Water Cement Ratio

Minimum Grade of Concrete

i) Mild 220 0.60 - 300 0.55 M20

ii) Moderate 240 0.60 M15 300 0.50 M25

iii) Severe 250 0.50 M20 320 0.45 M30

iv) Very Severe

260 0.45 M20 340 0.45 M35

v) Extreme 280 0.40 M25 360 0.40 M40

Page 41: Gl Cc Mix Design 071110

41

From the table 5 of IS: 456–2000, the minimum Cement content & W/C ratio, For moderate, for RCC are 300Kgs. & 0.5

The Cement content = 394Kgs. > 300Kgs. Hence Ok

The W/C Ratio = 0.47 < 0.5 Hence Ok

Page 42: Gl Cc Mix Design 071110

42

TEST REPORTConcrete Mix RCC M30 with 20.0mm M.S.A.

Sl.No.

Particulars Result

1 Characteristic Compressive strength in N/Sq.mm

30

2 Maximum size of Aggregate in mm 20.0

3 Type of Exposure Moderate

4 Type of Site control Good

5 Target Average Compressive Strength in N/Sq.mm

38.2

6 Workability in terms of Slump in mm 25-75

7 Mode of Compaction Vibration

8 Mix Partiuclars:a. Water-Cement Ratiob. Materials per cubic metre of concrete in

Kg.i) Waterii) Cement (OPC 43 Grade)iii) Fine Aggregateiv) Coarse Aggregate

c. Mix Portion by weight

0.47

185394675

11231:1.71:2.85

Page 43: Gl Cc Mix Design 071110

43

• Secondary Slides:

Page 44: Gl Cc Mix Design 071110

44

Sieve Analysis of Fine Aggregate 

•Weight of sample = 500g (approx)•Observations:

Sievesize

Weight retained(g)Cumulative

weight retained (g)

% Cumulative

weight retained (g)

% Passing

IS:383-1970 Specifications

Zone =IITrail 1 Trail2 Total

10 mm 0 0 0 0 0 100 100

4.75 mm 2 2 4 4 0 100 90-100

2.36 mm 6 7 13 17 2 98 75-100

1.18 mm 166 165 331 348 35 65 55-90

600 micron 118 117 235 583 58 42 35-59

300 micron 175 160 335 918 92 8 8-30

150 micron 36 42 78 996 100 0 0-10

150 micron pass 2 2 4 - - - -

Page 45: Gl Cc Mix Design 071110

45

Zones of Fine Aggregate 

Sieve Size

IS : 383 – 1970

% Passing for

Zone I Zone II Zone III Zone IV

10.00 mm 100 100 100 100

 4.75 mm 90-100 90-100 90-100 95-100

 2.36 mm 60-95 75-100 85-100 95-100

1.18 mm  30-70 55-90 75-100 90-100

600 micron  15-34 35-59 60-79 80-100

300 micron5-20 8-30 12-40 15-50

150 micron  0-10 0-10 0-10 0-15

Page 46: Gl Cc Mix Design 071110

46

Sieve Analysis of Coarse Aggregate2 20 mm aggregate : a.       Minimum weight of sample = 25 Kg b.      Observations :

Sievesize

Weight retained

(Kg)

Cumulative weight

retained (Kg)

% Cumulative

weight retained

(Kg)

% Passing

IS:383-1970 Specifications

GradedSingle sized

40 0.0 0.0 0 100 100 100

20 4.7 4.7 10 90 95-100 85-100

10 41.546.2

97 3 25-55 0-20

4.75 1.6 47.8 100 0 0-10 0-5

4.75 P 0 47.8 - - - -

Page 47: Gl Cc Mix Design 071110

47

Sieve Analysis of Coarse Aggregate2 10 mm aggregate : a.       Minimum weight of sample = 12 Kg b.      Observations :

Sievesize

Weight retained

(Kg)

Cumulative weight

retained (Kg)

% Cumulative

weight retained

(Kg)

% Passing

IS:383-1970 Specifications

Single Sized

12.5 0.0 0.0 0 100 100

10 5.4 5.4 15 85 85-100

4.75 24.329.7

81 19 0-20

2.36 6.9 36.6 100 0 0-5

2.36 P 0 36.6 - - - -

Page 48: Gl Cc Mix Design 071110

48

N = 20 N = 20

Avg = 30 Avg = 35

27,30,30,32,35,27,33,34,29,28,30,28,31,32,26,34,33,25,27,29

28, 32,35,38,40,34,35,35,36,39,33,32,32,34,37,32,35,38,39,36

Total = 600 Total = 700

Target mean compressive strength

Page 49: Gl Cc Mix Design 071110

49

The value of ‘S’ depends on Degree of Site control

and grade of concrete as given in I.S: 456–2000 (Table.8)

Sl.No.

ConcreteGrade

Good Fair

S 1.65XS

Fck

S 1.65XS

Fck

N/mm2 Kg/cm2 N/mm2 Kg/cm2

1 M10 3.5 58 15.8 161 4.5 7.4 17.4 178

2 M15 3.5 58 20.8 212 4.5 7.4 22.4 229

3 M20 4.0 6.6 26.6 271 5.0 8.3 28.3 288

4 M25 4.0 6.6 31.6 322 5.0 8.3 33.3 339

5 M30 5.0 8.3 38.3 390 6.0 9.9 39.9 407

6 M35 5.0 8.3 43.3 441 6.0 9.9 44.9 458

Page 50: Gl Cc Mix Design 071110

50

Step IV:-Fixation of Water Cement ratios for trial mixes.

Sl.No.

Required GradesTrial W/C

1 M20, M15, M10 0.55, 0.6, 0.9

2 M25, M20, M15 0.5, 0.6, 0.7

Page 51: Gl Cc Mix Design 071110

51

Final Mix for RCC-M25:-From the graph, for a target strength of 322 Kg/Cm2, W/C ratio = 0.57 which is > 0.5, So, limit W/C ratio to 0.5 only.Cement = 185 / 0.5 = 370 Kg.Substituting the values in Eq(1), we get1000 = 185 + 370/3.0 + (1/0.38) * fa /2.6)fa = 683 Kg. Substituting the values in Eq(2), we get1000 = 185 + 370/3.0 + (1/0.62) * ca /2.65)ca = 1136 Kg. So the mix proportion works out to beW : C : fa : ca = 185 : 370 : 683 : 1136= 0.50 : 1 : 1.85 : 3.07

Page 52: Gl Cc Mix Design 071110

52

Specific Gravity of Cement [ IS : 4031 – 1988]:

Specific gravity of cement (Sc) (W2 - W1)= ---------------------------- x 0.79 (W4 - W1) - (W3 - W2)

Where,

W1 = Weight of specific gravity bottle in gW2 = Weight of specific gravity bottle with about half filled cement in gW3 = Weight of specific gravity bottle with about half filled cement

& rest is filled with kerosene in g.W4 = Weight of specific gravity bottle completely filled with kerosene in g0.79 = Specific Gravity of Kerosene.

Page 53: Gl Cc Mix Design 071110

53

Specific Gravity of Fine Aggregate & Coarse Aggregate [ IS : 2386 (Part.3) - 1963]:

D Specific gravity (Gs) = --------------

C – ( A – B)

Where,

A = Weight of Pycnometer vessel containing sample & filled with distilled water in g B = Weight of Pycnometer completely filled with distilled water only in g C = Weight of saturated surface dry sample in g D = Weight of oven dried sample in g

Page 54: Gl Cc Mix Design 071110

54

Page 55: Gl Cc Mix Design 071110

55