glycol dehydration pump got you down? ratings of …

2
PUMP RATINGS OF 1500 PSI AND 350°F Viking Pump’s external gear GL-407 Series™ and GL-410 Series™ products offer a reliable pumping solution for circulation of triethylene glycol (TEG) in natural gas dehydration systems. FEATURES & BENEFITS Trusted Viking Pump External Gear Design Fewer moving wear components Smooth flow with no pulsation dampening equipment required Fixed Precision Clearances Enhanced thermal capabilities for easier start-up Higher overall temperature rating improves tolerance for unplanned system changes All Pumps Wet Tested State of the art testing equipment used to confirm performance prior to shipment Hardened Internals Increase pressure capabilities, extend service life and minimize wear Mechanical Seal Less susceptible to leakage and easy in-field replacement Multiple Drive Configurations Jaw type coupling eliminates the mess and maintenance of an oil bath Motor mounted for easy drop-in replacement Optional Head Support Pump can be plumbed using hard or flexible pipe PERFORMANCE GL-41009 Pump & Motor Unit GL-41026 Double Pump Model Port Size & Type Flow Rate @ 1765 RPM on 8 cPs Glycol @ 1200 psi Max. Continuous Pressure Max. Recommended Temperature Approximate Shipping Weight Ductile Iron Externals Inch GPM GPH PSI Deg. F Lbs. GL-40758-G0B 1" NPT 3.6 216 1500 350** 27 GL-40782-G0B 1" NPT 6 360 1500 350** 28 GL-40712-G0B 1" NPT 8.1 486 1500 350** 40 GL-41009-G0B 2" NPT* 11 660 1500 350** 58 GL-41013-G0B 2" NPT* 17.1 1026 1500 350** 61 GL-41018-G0B 2" NPT* 20.2 1212 1500 350** 77 GL-41026-G0B 2" NPT* 35.5 2130 1500 350** 81 GL-41039-G0B 2" NPT* 48.1 2886 1500 350** 115 GL-41415-G0B 2" NPT* 42.2 2532 1500 350** 230 GL-41430-G0B 2" NPT* 87 5220 1500 350** 330 GL-41445-G0B 3" NPT* 131.3 7878 1500 350** 460 * Also available with Butt-Weld Weld-Neck Flange Adapters ** Higher Temperature capability available with alternate construction features/materials *** Pump Only weight, does not include weight of M-Drive Mounting Bracket NOTE: Please contact Viking Pump for performance curves specific to your application. TESTIMONIALS “Viking’s engineering team listened to us and was willing to keep trying different things in order to make a pump that can handle the challenges of glycol dehydration...Switching to Viking has been a great success all around. The customers are happy and so are we!” – Jerry, Service Manager, Marcellus Shale “Viking has the best customer service I have experienced in the industry. The pumps have performed flawlessly, far better than similar setups. Quick and easy conversion and setup.” – Justin, Facilities Technician Sr., Utica Shale GLYCOL DEHYDRATION PUMP GOT YOU DOWN? STAY UP & RUNNING WITH VIKING GLYCOL PUMPS!

Upload: others

Post on 15-Oct-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GLYCOL DEHYDRATION PUMP GOT YOU DOWN? RATINGS OF …

PUMP RATINGS

OF1500 PSIAND

350°FViking Pump’s external gear GL-407 Series™ and GL-410 Series™ products offer a reliable pumping solution for circulation of triethylene glycol (TEG) in natural gas dehydration systems.

FEATURES & BENEFITS ∙ Trusted Viking Pump External Gear Design

▸ Fewer moving wear components

▸ Smooth flow with no pulsation dampening equipment required

∙ Fixed Precision Clearances ▸ Enhanced thermal capabilities for easier start-up

▸ Higher overall temperature rating improves tolerance for unplanned system changes

∙ All Pumps Wet Tested ▸ State of the art testing equipment used to confirm performance prior to shipment

∙ Hardened Internals ▸ Increase pressure capabilities, extend service life and minimize wear

∙ Mechanical Seal ▸ Less susceptible to leakage and easy in-field replacement

∙ Multiple Drive Configurations ▸ Jaw type coupling eliminates the mess and maintenance of an oil bath

▸ Motor mounted for easy drop-in replacement

∙ Optional Head Support ▸ Pump can be plumbed using hard or flexible pipe

PERFORMANCE

GL-41009 Pump & Motor Unit

GL-41026 Double Pump

ModelPort Size & Type

Flow Rate @ 1765 RPM on 8 cPs Glycol @ 1200 psi

Max. Continuous Pressure

Max. Recommended Temperature

Approximate Shipping Weight

Ductile Iron Externals Inch GPM GPH PSI Deg. F Lbs.GL-40758-G0B 1" NPT 3.6 216 1500 350** 27GL-40782-G0B 1" NPT 6 360 1500 350** 28GL-40712-G0B 1" NPT 8.1 486 1500 350** 40GL-41009-G0B 2" NPT* 11 660 1500 350** 58GL-41013-G0B 2" NPT* 17.1 1026 1500 350** 61GL-41018-G0B 2" NPT* 20.2 1212 1500 350** 77GL-41026-G0B 2" NPT* 35.5 2130 1500 350** 81GL-41039-G0B 2" NPT* 48.1 2886 1500 350** 115GL-41415-G0B 2" NPT* 42.2 2532 1500 350** 230GL-41430-G0B 2" NPT* 87 5220 1500 350** 330GL-41445-G0B 3" NPT* 131.3 7878 1500 350** 460

* Also available with Butt-Weld Weld-Neck Flange Adapters ** Higher Temperature capability available with alternate construction features/materials*** Pump Only weight, does not include weight of M-Drive Mounting BracketNOTE: Please contact Viking Pump for performance curves specific to your application.

TESTIMONIALS“Viking’s engineering team listened to us and was willing to keep trying different things in order to make a pump that can handle the challenges of glycol dehydration...Switching to Viking has been a great success all around. The customers are happy and so are we!”

– Jerry, Service Manager, Marcellus Shale

“Viking has the best customer service I have experienced in the industry. The pumps have performed flawlessly, far better than similar setups. Quick and easy conversion and setup.”

– Justin, Facilities Technician Sr., Utica Shale

GLYCOL DEHYDRATION PUMP GOT YOU DOWN?

STAY UP & RUNNING WITH VIKING GLYCOL PUMPS!

Page 2: GLYCOL DEHYDRATION PUMP GOT YOU DOWN? RATINGS OF …

VIKING PUMP, INC. A Unit of IDEX Corporation 406 State Street Cedar Falls, Iowa 50613 U.S.A. vikingpump.com

© Copyright 2020 Viking Pump, Inc. All Rights Reserved. Rev 020620

THE VIKING PUMP ADVANTAGE ∙ With over 105 years of experience providing positive displacement pumping solutions, Viking Pump has a

long history of providing engineered solutions for tough applications

∙ Dedicated sales specialists are supported by a team of customer service representatives and engineers

∙ Knowledgeable team of application engineers available to help with product selection and technical support

∙ USA based company with vertically integrated manufacturing process

VERTICALLY INTEGRATED PRODUCTION PROCESS:Viking Pump operates two foundries, a 250,000+ sq. ft. machining, assembly and testing center, and an extensive product engineering and testing lab in its world headquarters in Cedar Falls, Iowa, USA. This level of vertical integration ensures maximum quality, ability to satisfy special needs, and to meet project schedules.

ALL PUMPS FACTORY TESTEDState of the art testing equipment used to confirm performance prior to all shipments

TEST LABOur world-class lab gives Viking the ability to test its glycol pump designs across a range of relevant variables

TESTING

WORLD HQ - USA

ASSEMBLYMACHINING

MACHINE SHOP

SHAKEOUT, CHIP & GRIND

IRON FOUNDRY

MELT & MOLD

ALLOYS FOUNDRY

1 2 3 4 5

CONTACT YOUR VIKING PUMP GLYCOL SPECIALISTS:

Brad [email protected] (319) 215-3050 Mobile

Josh [email protected]

(319) 296-8119 Mobilevikingpump.com/GlycolDehy