gov.uk · indicator (ami) ms4 variable message sign pp 3,/(6 scale n.t.s 3d view of gantry drawing...
TRANSCRIPT
-
M4 junctions 3 to 12 smart motorway
TR010019
Volume 2.0: plans, drawings and sections
2.8
Gantry General Arrangements
APFP regulation 5 (2) (o) & 5 (2) (p) & 6 (2)
Planning Act 2008 Infrastructure Planning (Applications: Prescribed Forms and Procedure) Regulations 2009
Revision 0 March 2015
-
3650LANE 1
3500LANE 2
3400LANE 3
3200LANE 4
VARIESCENTRAL RESERVE
3200LANE 4
3400LANE 3
3500LANE 2
3650LANE 1
5800
MIN
.
VARIES VARIES
VARI
ES22
50 (T
YP)
VARIES
AMI ADVANCED MOTORWAY INDICATOR(1 PER LANE - TYP)
ENFORCEMENT SIGN (TYP)
SCALE 1:100
FRONT ELEVATION
SAFETY BARRIERSAFETY BARRIER
GROUND PROFILE VARIESDEPENDING ON LOCATION
JUNCTION BOX
GROUND PROFILE VARIESDEPENDING ON LOCATION
600
600
MS4 VARIABLE MESSAGE SIGN (TYP)
INDICATIVE SIGN ENVELOPE
CABLE TRAY
VARI
ES22
50 (T
YP)
2250
SCALE 1:50
SIDE ELEVATION
1500
300
REINFORCED CONCRETE FOUNDATION
AMI
MS4 VARIABLE MESSAGE SIGN
VARIES
SCALE 1:100
PLAN ON GANTRY
6500
1100
3650LANE 1
3500LANE 2
3400LANE 3
3200LANE 4
VARIESCENTRAL RESERVE
3200LANE 4
3400LANE 3
3500LANE 2
3650LANE 1
VARIES VARIES
AMI ADVANCED MOTORWAY INDICATOR(1 PER LANE - TYP)INDICATIVE SIGN LOCATION
SCALE N.T.S
3D VIEW OF GANTRY
Drawing Number
Drawing Title
Scale at A1
Highways Agency
Alliance Document Reference Rev
NOTES
Job Title
TR010019 - 2.8
AS SHOWN
The Cube199 Wharfside StreetBirminghamB1 1RN
M4 JUNCTIONS 3 TO 12
SMART MOTORWAY
GENERIC GANTRY DETAILS
REGULATION 5 (2) (o) & 5 (2) (p) & 6 (2)
GANTRY TYPE 1
SUPERSPAN PORTAL GANTRY
Rev # Revision DetailsRevision Date Drawn Check Review Appr'd
1. All dimensions are in millimetres unless noted otherwise.
2. Drawing represents a typical indicative detail for this gantry type. The information on thisdrawing should not be considered representative of the proposals at a particular gantrylocation.
3. Provision of Direction Signs, Variable Message Signs and Advance Motorway Indication willvary according to gantry location.
-
1R GMSBBRCADFOR REVIEW PRIOR TO DCO APPLICATION5/3/15
0D -GMBRCADFIRST DRAFTJAN 15
2F GMSBBRCADSUBMITTED WITH DCO APPLICATION20/3/15
-
3650LANE 1
3500LANE 2
3400LANE 3
3200LANE 4
VARIESCENTRAL RESERVE
OTHER SIDE ON CARRIAGEWAY
5800
MIN
.
VARIES
VARI
ES22
10 (T
YP)
VARIES
SCALE 1:100
FRONT ELEVATION
SAFETY BARRIER
GROUND PROFILE VARIESDEPENDING ON LOCATION
600
AMI ADVANCED MOTORWAY INDICATOR(1 PER LANE - TYP)
INDICATIVESIGN ENVELOPE
2250
VARI
ES22
50
PILECAP
CABLE TRAY
SCALE 1:50
SIDE ELEVATION
1500
AMI
INDICATIVE SIGN LOCATION
VARIES
SCALE 1:100
PLAN ON GANTRY
6500
1100
3650LANE 1
3500LANE 2
3400LANE 3
3200LANE 4
VARIESCENTRAL RESERVE
VARIES OTHER SIDE ON CARRIAGEWAY
INDICATIVE SIGN LOCATION
SCALE N.T.S
3D VIEW OF GANTRY
Drawing Number
Drawing Title
Scale at A1
Highways Agency
Alliance Document Reference Rev
NOTES
Job Title
TR010019 - 2.8
AS SHOWN
The Cube199 Wharfside StreetBirminghamB1 1RN
M4 JUNCTIONS 3 TO 12
SMART MOTORWAY
GENERIC GANTRY DETAILS
REGULATION 5 (2) (o) & 5 (2) (p) & 6 (2)
GANTRY TYPE 2
SINGLE SPAN PORTAL GANTRY
Rev # Revision DetailsRevision Date Drawn Check Review Appr'd
1. All dimensions are in millimetres unless noted otherwise.
2. Drawing represents a typical indicative detail for this gantry type. The information on thisdrawing should not be considered representative of the proposals at a particular gantrylocation.
3. Provision of Direction Signs, Variable Message Signs and Advance Motorway Indication willvary according to gantry location.
1R GMSBBRCADFOR REVIEW PRIOR TO DCO APPLICATION5/3/15
0D -GMBRCADFIRST DRAFTJAN 15
2F GMSBBRCADSUBMITTED WITH DCO APPLICATION20/3/15
-
3200LANE 4
3400LANE 3
3500LANE 2
3650LANE 1
VARIES (19000 MAX.)
600
VARI
ES50
00 (A
PPRO
X.) T
YP19
00
VARIES
MS4 VARIABLE MESSAGE SIGN (TYP)
4440
3160
AMI ADVANCED MOTORWAY INDICATOR(1 PER LANE - TYP)
ENFORCEMENT SIGN (TYP)
SCALE 1:100
FRONT ELEVATION
SAFETY BARRIER
INDICATIVE SIGNENVOLOPE
VARIES
1700
SCALE 1:100
PLAN ON GANTRY
3200LANE 4
3400LANE 3
3500LANE 2
3650LANE 1
VARIES
1900
450
VARI
ES
TRAFFIC FACE
1700
SCALE 1:50
SIDE ELEVATION
MAIN CABLE TRAY
REINFORCED CONCRETEFOUNDATION
ADVANCED MOTORWAYINDICATOR (AMI)
MS4 VARIABLE MESSAGESIGN
SCALE N.T.S
3D VIEW OF GANTRY
Drawing Number
Drawing Title
Scale at A1
Highways Agency
Alliance Document Reference Rev
NOTES
Job Title
TR010019 - 2.8
AS SHOWN
The Cube199 Wharfside StreetBirminghamB1 1RN
M4 JUNCTIONS 3 TO 12
SMART MOTORWAY
GENERIC GANTRY DETAILS
REGULATION 5 (2) (o) & 5 (2) (p) & 6 (2)
GANTRY TYPE 3
SUPERSPAN CANTILEVER GANTRY
Rev # Revision DetailsRevision Date Drawn Check Review Appr'd
1. All dimensions are in millimetres unless noted otherwise.
2. Drawing represents a typical indicative detail for this gantry type. The information on thisdrawing should not be considered representative of the proposals at a particular gantrylocation.
3. Provision of Direction Signs, Variable Message Signs and Advance Motorway Indication willvary according to gantry location.
-
1R GMSBBRCADFOR REVIEW PRIOR TO DCO APPLICATION5/3/15
0D -GMBRCADFIRST DRAFTJAN 15
2F GMSBBRCADSUBMITTED WITH DCO APPLICATION20/3/15
-
5800
MIN
.
VARIES (12000 MAX.)
VARI
ES(6
000 T
YPIC
AL)
600
3650LANE 1
3500LANE 2
3400LANE 3
3200LANE 4
VARIES
SAFETY BARRIER
SCALE 1:100
FRONT ELEVATION
GROUND PROFILE VARIESDEPENDING ON LOCATION
INDICITAVE SIGN ENVELOPE
3650LANE 1
3500LANE 2
3400LANE 3
3200LANE 4
600
VARI
ES53
00 (A
PPRO
X.) T
YP
VARIES
SCALE 1:100
REAR ELEVATION
5800
(MIN
.)
GROUND PROFILE VARIESDEPENDING ON LOCATION
VARIES (12000 MAX.)
INDICATIVE SIGN ENVELOPE
VARI
ES(6
000 T
YPIC
AL)
SCALE 1:50
SIDE ELEVATION
PILE CAP (VARIES)1500
300
ALTERNATIVE SIGN POSITION
SCALE N.T.S
3D VIEW OF GANTRY
Drawing Number
Drawing Title
Scale at A1
Highways Agency
Alliance Document Reference Rev
NOTES
Job Title
TR010019 - 2.8
AS SHOWN
The Cube199 Wharfside StreetBirminghamB1 1RN
M4 JUNCTIONS 3 TO 12
SMART MOTORWAY
GENERIC GANTRY DETAILS
REGULATION 5 (2) (o) & 5 (2) (p) & 6 (2)
GANTRY TYPE 4
SIGN ONLY CANTILEVER GANTRY
Rev # Revision DetailsRevision Date Drawn Check Review Appr'd
1. All dimensions are in millimetres unless noted otherwise.
2. Drawing represents a typical indicative detail for this gantry type. The information on thisdrawing should not be considered representative of the proposals at a particular gantrylocation.
3. Provision of Direction Signs, Variable Message Signs and Advance Motorway Indication willvary according to gantry location.
1R GMSBBRCADFOR REVIEW PRIOR TO DCO APPLICATION5/3/15
0D -GMBRCADFIRST DRAFTJAN 15
2F GMSBBRCADSUBMITTED WITH DCO APPLICATION20/3/15
-
VARIES
5800
MIN
.
REINFORCED CONCRETEFOUNDATION (EITHER NEW OREXISTING AS APPROPRIATE)
SCALE 1:50
FRONT ELEVATIONEDGE OF CARRIAGEWAY
SAFETY BARRIER
4155
VARI
ES
MS4 VARIABLEMESSAGE SIGN
VARIES
GROUND PROFILE VARIESDEPENDING ON LOCATION
SCALE 1:50
SIDE ELEVATION
1500
300
SIGNAL FACE ANGLED TOCARRIAGEWAY AS APPROPRIATE
4155
VARI
ES
610
SCALE 1:50
PLAN
REINFORCED CONCRETEFOUNDATION
1. All dimensions are in millimetres unless noted otherwise.
2. Drawing represents a typical indicative detail for this gantry type. The information on thisdrawing should not be considered representative of the proposals at a particular gantrylocation.
3. Provision of Direction Signs, Variable Message Signs and Advance Motorway Indication willvary according to gantry location.
Drawing Number
Drawing Title
Scale at A1
Highways Agency
Alliance Document Reference Rev
NOTES
Job Title
TR010019 - 2.8
AS SHOWN
The Cube199 Wharfside StreetBirminghamB1 1RN
M4 JUNCTIONS 3 TO 12
SMART MOTORWAY
GENERIC GANTRY DETAILS
REGULATION 5 (2) (o) & 5 (2) (p) & 6 (2)
GANTRY TYPE 5A
MS4 SIGNAL GANTRY (OPTION A)
Rev # Revision DetailsRevision Date Drawn Check Review Appr'd
SCALE N.T.S
3D VIEW OF GANTRY
1R GMSBBRCADFOR REVIEW PRIOR TO DCO APPLICATION5/3/15
0D -GMBRCADFIRST DRAFTJAN 15
2F GMSBBRCADSUBMITTED WITH DCO APPLICATION20/3/15
-
SCALE 1:50
SIDE ELEVATION
1500
300
508500
SIGNAL FACE ANGLED TOCARRIAGEWAY AS APPROPRIATE
3350
VARI
ES
SCALE 1:50
PLAN
REINFORCED CONCRETEFOUNDATION
VARI
ES33
50
VARIES
VARIES
5800
MIN
.
REINFORCED CONCRETEFOUNDATION (EITHER NEW OREXISTING AS APPROPRIATE)
SCALE 1:50
FRONT ELEVATION
TYPE F12 - MS4 - A1SUPERSTRUCTURE
MS4 VARIABLEMESSAGE SIGN
EDGE OF CARRIAGEWAY
SAFETY BARRIER
GROUND PROFILE VARIESDEPENDING ON LOCATION
SCALE N.T.S
3D VIEW OF GANTRY
1. All dimensions are in millimetres unless noted otherwise.
2. Drawing represents a typical indicative detail for this gantry type. The information on thisdrawing should not be considered representative of the proposals at a particular gantrylocation.
3. Provision of Direction Signs, Variable Message Signs and Advance Motorway Indication willvary according to gantry location.
Drawing Number
Drawing Title
Scale at A1
Highways Agency
Alliance Document Reference Rev
NOTES
Job Title
TR010019 - 2.8
AS SHOWN
The Cube199 Wharfside StreetBirminghamB1 1RN
M4 JUNCTIONS 3 TO 12
SMART MOTORWAY
GENERIC GANTRY DETAILS
REGULATION 5 (2) (o) & 5 (2) (p) & 6 (2)
GANTRY TYPE 5B
MS4 SIGNAL GANTRY (OPTION B)
Rev # Revision DetailsRevision Date Drawn Check Review Appr'd
1R GMSBBRCADFOR REVIEW PRIOR TO DCO APPLICATION5/3/15
0D -GMBRCADFIRST DRAFTJAN 15
2F GMSBBRCADSUBMITTED WITH DCO APPLICATION20/3/15
-
SCALE 1:50
REAR ELEVATION
8590
VARI
ES66
00 (A
PPRO
X.),
TYP
EDGE OF CARRIAGEWAY
3070
SAFETY BARRIER
2500 (TYP)
5800
MIN
.
1500
GROUND PROFILE VARIESDEPENDING ON LOCATION
SCALE 1:50
SIDE ELEVATION
VARI
ES66
00 (A
PPRO
X.) T
YP
1500
300
SIGNAL FACE ANGLED TOCARRIAGEWAY AS APPROPRIATE
800500
SCALE 1:50
PLAN
REINFORCED CONCRETEFOUNDATION
2500
2500
SCALE 1:50
FRONT ELEVATION
8590
2500 (TYP)
EDGE OF CARRIAGEWAY
5800
MIN
.
600
SAFETY BARRIER
MS3 VARIABLEMESSAGE SIGN
1500
REINFORCED CONCRETEFOUNDATION (EITHER NEW OREXISTING AS APPROPRIATE)
GROUND PROFILE VARIESDEPENDING ON LOCATION
SCALE N.T.S
3D VIEW OF GANTRY
Drawing Number
Drawing Title
Scale at A1
Highways Agency
Alliance Document Reference Rev
NOTES
Job Title
TR010019 - 2.8
AS SHOWN
The Cube199 Wharfside StreetBirminghamB1 1RN
M4 JUNCTIONS 3 TO 12
SMART MOTORWAY
GENERIC GANTRY DETAILS
REGULATION 5 (2) (o) & 5 (2) (p) & 6 (2)
GANTRY TYPE 6
MS3 SIGNAL GANTRY
Rev # Revision DetailsRevision Date Drawn Check Review Appr'd
1. All dimensions are in millimetres unless noted otherwise.
2. Drawing represents a typical indicative detail for this gantry type. The information on thisdrawing should not be considered representative of the proposals at a particular gantrylocation.
3. Provision of Direction Signs, Variable Message Signs and Advance Motorway Indication willvary according to gantry location.
1R GMSBBRCADFOR REVIEW PRIOR TO DCO APPLICATION5/3/15
0D -GMBRCADFIRST DRAFTJAN 15
2F GMSBBRCADSUBMITTED WITH DCO APPLICATION20/3/15