green wall
TRANSCRIPT
![Page 1: Green Wall](https://reader031.vdocuments.net/reader031/viewer/2022013102/544a434faf7959ac438b45ff/html5/thumbnails/1.jpg)
2x6 BLOCKING AT GSKY FRAME
SCREW LOCATIONS MAY BE
REQUIRED (CHECK WITH
PROJECT ENGINEER)
GSKY SS FRAME
1/4" DIA WOOD OR METAL
SCREW
STUD WALL STRUCTUREGSKY TOP TRIM
GSKY SIDE TRIM
GSKY STANDARD
GREEN WALL PANEL
WATERPROOFING
3/4" PLYWOOD BEHIND GREEN
WALL
WALL FINISH TO MAKE
RECESSED GREEN
WALL OPTION
SEE 8-p-1 FOR
DRAIN DETAIL
2x6 BLOCKING AT GSKY FRAME
SCREW LOCATION MAYBE
REQUIRED (CHECK WITH
PROJECT ENGINEER)
1/4" DIA WOOD OR
METAL SCREW
2"
1 1/
2"
5"
3"
4" 11 7/8" TYP.
GSKY SS FRAME
WATERPROOFING
GSKY TRIM MOUNTING ANGLE
STAINLESS OR ALUMINUM GSKY
SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
GREEN WALL CAN BE
RECESSED INTO
WALL FINISH
3/4" PLYWOOD BEHIND GREEN
WALL
WOOD OR METAL STUD
WALL STRUCTURE
SEE 10-p AND 11-p FOR
IRRIGATION DETAIL
GSKY TRIM MOUNTING
ANGLE
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
GSKY SS FRAME
5"
6 1/2"
3"4"11
7/8
"
GSKY IRRIGATION
DRIP LINE
WATERPROOFING
1/4" DIA WOOD OR
METAL SCREW
WOOD OR METAL STUD
WALL STRUCTURE
3/4" PLYWOOD
BEHIND GREEN WALL
2x6 BLOCKING AT GSKY
FRAME SCREW LOCATION
MAYBE REQUIRED (CHECK
WITH PROJECT ENGINEER)
1 1/
2"
2"
1/4" DIA SS WOOD OR
METAL SCREW
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
GSKY FRAME
WATERPROOFING
3/4" PLYWOOD BEHIND
GREEN WALL
2x6 BLOCKING AT GSKY
FRAME SCREW LOCATION
MAYBE REQUIRED (CHECK
WITH PROJECT ENGINEER)
DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*3/4" PLYWOOD MUST BE INSTALLED BEHIND GREEN WALL AREA
*BLOCKING AT GSKY FRAME SCREW LOCATIONS MAY BE REQUIRED CHECK WITH PROJECT ENGINEER
*STUD LOCATION MUST BE IDENTIFIED ON THE AS-BUILT DRAWING
*GREEN WALL CAN BE RECESSED AT INDOOR WALL (NOTE THAT GUTTER WILL EXTEND OUT; SEE 8-p-1 FOR DETAIL)
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
1
3D VIEW / STUD WALL
SCALE 3/8" - 1'-0" (FILE # 3-p-1)
2
PLAN DETAIL / STUD WALL
SCALE 3/4" - 1'-0" (FILE # 3-p-2)
3
SECTION DETAIL / STUD WALL
SCALE 3/4" - 1'-0" (FILE # 3-p-3)
4
FASTENER DETAIL / STUD WALL
SCALE 3" - 1'-0" (FILE # 3-p-4)
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
3D VIEW
PLAN DETAIL
SECTION DETAIL
FASTENER DETAIL
STUD WALL STRUCTURE / INTERIOR OR EXTERIOR
AS NOTED
3-p