grounding and cabling for the small studio
DESCRIPTION
Grounding and Cabling for the Small Studio. David Etlinger 1/17/2006. Disclaimers. NEVER defeat the AC ground!! (round prong) AC current can KILL – if in doubt, stop and get more info I am not an electrician so don’t count on me to keep you safe. Objectives. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/1.jpg)
Grounding and Cabling Grounding and Cabling for the Small Studiofor the Small Studio
David EtlingerDavid Etlinger
1/17/20061/17/2006
![Page 2: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/2.jpg)
Disclaimers
NEVER defeat the AC ground!! (round prong)
AC current can KILL – if in doubt, stop and get more info
I am not an electrician so don’t count on me to keep you safe
![Page 3: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/3.jpg)
Objectives
How can we get rid of that annoying hum?!?
How can we reduce the noise floor through proper cabling?
How can we keep our equipment and ourselves safe while doing it?
Can we do this systematically, not haphazardly?
![Page 4: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/4.jpg)
Basic Definitions
Voltage (Potential) – difference in charge between two points (V – Volts)
Current – the flow of electricity (positive to negative) (I – Amperes)
Resistance – a component’s opposition to current flow (R – Ohms)
V = I R
![Page 5: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/5.jpg)
Part IPart I
GroundingGrounding
![Page 6: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/6.jpg)
Grounding (Earthing)
• Ground (1) – Literally the Earth, effectively a point with 0 potential and infinite charge-holding capacity
• Ground (2) – The lowest potential point in a circuit, serving as a current return path
SignalGround
ChassisGround
EarthGround
![Page 7: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/7.jpg)
Two-Prong Outlets
Hot – Black, Red or BlueNeutral - WhiteWhite
![Page 8: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/8.jpg)
Three-Prong Outlets
Hot – Black, Red or BlueNeutral – WhiteWhiteGround – Green
![Page 9: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/9.jpg)
Already a Problem
• Many, many home AC circuits are wired improperly
• This can cause noise and shock hazards
• Use a multimeter or $5 Radioshack tester to verify every AC outlet
![Page 10: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/10.jpg)
Short Circuit with Proper Grounding
![Page 11: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/11.jpg)
Short with Broken Ground
Mics and Electric Guitars with broken grounds are especially dangerous
![Page 12: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/12.jpg)
![Page 13: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/13.jpg)
Ground Noise
• All signals are referenced to ground
• Noise (voltage changes) on the ground line create noise in the signal
• Since AC oscillates at 60Hz, this often results in a 60Hz hum
![Page 14: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/14.jpg)
Ground Loops
• “One point, two paths to ground”
• Current requires a closed loop to flow
• Two paths to ground makes a closed loop
• Ground noise is then possible
![Page 15: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/15.jpg)
![Page 16: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/16.jpg)
Chassis-to-Chassis
• Touching chassis can form an electrical connection
• Rackmount rails can also connect chassis
• This can be good or bad, depending on the situation
![Page 17: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/17.jpg)
Noise Source: Two Circuits
Easiest solution: Put both devices on one AC circuit
![Page 18: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/18.jpg)
Noise Source: Dirty Ground
• Remember V = I R : Low resistance means big current
• Solve with a power conditioner (Furman, etc.) or isolation transformer• Or put everything on one AC outlet, but watch the power draw
![Page 19: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/19.jpg)
Induced Current
![Page 20: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/20.jpg)
Induced Ground Current
![Page 21: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/21.jpg)
Solution
![Page 22: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/22.jpg)
Induced Current, Cont’d
• Usually, 6” separation is enough to eliminate induced current
• Wall-wart transformers have unpredictable fields; keep them as isolated as possible
• Induced currents cannot be totally eliminated
![Page 23: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/23.jpg)
Other Sources of Ground Noise
• Internal Power Supply (Induction and Capacitance)– Upgrade or mod the equipment– use balanced cables
![Page 24: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/24.jpg)
Fixing Ground Loops Put everything on one AC circuit
• Use a current meter like Kill-a-Watt or Power Angel to measure current draw
Separate Signal cables from AC cables (and esp. Wall-wart transformers)• Try to keep at least 6” between• Cross at 90° if necessary
Use Balanced Cables wherever possible
![Page 25: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/25.jpg)
Part IIPart II
CablingCabling
![Page 26: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/26.jpg)
Balanced Cabling: CMR
![Page 27: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/27.jpg)
Balanced Advantages
• High rejection of ground noise
• Also rejects external EMF
• CMR not perfect; still wise to minimize ground noise
• Proper operation depends on proper ground wiring
![Page 28: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/28.jpg)
AC vs. Signal Ground
• AC Ground is designed for safety
• Signal Ground is an internal reference for circuit paths
• Signal Ground is usually tied to Chassis Ground at one point
• Balanced cables should ALWAYS use chassis ground
![Page 29: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/29.jpg)
![Page 30: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/30.jpg)
WRONG: Signal Ground
![Page 31: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/31.jpg)
RIGHT: Chassis Ground
![Page 32: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/32.jpg)
Problems
• Much old or cheap equipment uses signal ground
• Unfortunately, this can cause noise even with balanced connections
• The only choices are upgrading or modding
![Page 33: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/33.jpg)
Finding Improper Grounding
• Visual Inspection
• Use a multimeter to test for voltage between shield and chassis
• Should be very low (ideally 0V)– But, could tie to both chassis and signal
ground
![Page 34: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/34.jpg)
Fixing Improper Balanced I/O
• Best: Cut the trace to signal ground and bond to chassis ground
• Easier: Disconnect the cable shield at the end tied to signal ground– Breaks any ground loops– But shield is now an RF antenna– Can alleviate by bonding shield to chassis through a
0.01μF capacitor– But then why not just mod the equipment?!?
![Page 35: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/35.jpg)
Worst Case
• Both input and output tied to signal ground
• No standard solution, but most people connect one end of the shield
• Which end is unimportant, but you must make the same choice each time– Might be a very slight benefit to lifting at the
input side
![Page 36: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/36.jpg)
One More Problem
• Units with a wall-wart transformer are not connected to AC ground
• These units can have balanced I/O
• Solve this by bonding the ungrounded chassis to a known grounded chassis
![Page 37: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/37.jpg)
Sidebar: Cable Quality
Cable quality varies substantially
Foil shields: best protection but easily damagedUse in fixed installations
Braided shields: look for maximum coverage
![Page 38: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/38.jpg)
Some Brands
Pro Quality: Canare, Mogami Also good: Belden, Gepco, Rapco,
Whirlwind
AVOID: HOSA Monster: Good but way overpriced
Or make your own: pro quality at a budget price
Connectors: Neutrik, Switchcraft
![Page 39: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/39.jpg)
Unbalanced Cabling
• Two conductors: Hot and Neutral
• No CMR; no magnetic field rejection
• Often found on semi-pro or consumer gear
• ¼” TS (mono); RCA
• Always keep unbalanced runs as short as possible
![Page 40: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/40.jpg)
Shield goes to Signal Ground!
• Shield acts as current return path• Necessary to form a complete circuit• Not a “true” shield but does offer some
protection
![Page 41: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/41.jpg)
Best Solution: Convert to Balanced
![Page 42: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/42.jpg)
Next Best Solution: Transformers
Audio Isolation Transformers; DI Boxes; Many Preamps; etc.
www.whirlwindusa.com
![Page 43: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/43.jpg)
![Page 44: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/44.jpg)
Last Resort: Cut the Shield
• N.B.: Cutting the shield on a single-wire cable will ruin the cable!!
• We are going to cut the shield on a two-wire (“balanced”) cable
• This modified cable can then be used to connect unbalanced <-> balanced
![Page 45: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/45.jpg)
Most Common: Unbalanced Balanced
• Simply disconnect the shield at one end• TRS: sleeve; XLR: pin 1
![Page 46: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/46.jpg)
Balanced Unbalanced
![Page 47: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/47.jpg)
Balanced Unbalanced
![Page 48: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/48.jpg)
Balanced Unbalanced
![Page 49: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/49.jpg)
Hierarchy of Preference
Balanced --> Balanced• Unbalanced --> Balanced
• Balanced --> Unbalanced
• Unbalanced --> Unbalanced
Chassis-shielded at both ends• Chassis-shielded at one end, other end lifted
• Signal-shielded at one end, other end lifted
![Page 50: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/50.jpg)
More Info
• If the choice of which end to cut is arbitrary, make the same choice each time
• Many possible scenarios
• See the two Rane references for excellent charts
• Also see Jensen whitepapers for a more technical discussion
![Page 51: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/51.jpg)
Summary of Best Practices
Connect all devices to one AC circuit Use balanced I/O whenever possible Transformer-Isolate unbalanced lines
when possible• Cut shielding at one end if necessary
Keep signal lines away from AC (esp. wall-warts)• Cross signal and AC lines at 90° if necessary
![Page 52: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/52.jpg)
Noise Isolation Procedure
1. Disconnect everything
2. Connect monitors to main I/O; verify good grounding and no noise
3. Connect balanced gear one by one; verify no noise
4. Connect unbalanced gear one by one; modify until noise is acceptable
![Page 53: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/53.jpg)
Sidebar: Advanced Studio Grounding Pros:
Can reduce noise floor to commercial-studio levels
Cons: Complex Expensive Often a workaround for improper cabling or
equipment design
![Page 54: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/54.jpg)
Primary Techniques
Isolated Ground: drive a dedicated ground bar, completely separate from the main AC grid
Star Grounding: Use heavy copper wiring to ground every device to one central point
![Page 55: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/55.jpg)
Balanced Power
Common-Mode Rejection CancelsGround Noise (just like balanced audio!)
![Page 56: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/56.jpg)
Balanced Power Pros and Cons
ProsEliminates noise from reactive current
(i.e., bad internal design)Isolates from building power
ConsWon’t solve all ground loop problemsPricey!! ($1000 and up)
![Page 57: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/57.jpg)
Digital Audio Cables
• Digital signals themselves should be immune to ground noise
• But, the cabling can create ground loops that affect other signals
• AES/EBU: Isolation transformers prevent loops• Optical S/PDIF (TOSLink): No electrical
connection so no loops• Coaxial S/PDIF: Supposedly isolated but some
cheap equipment isn’t– Can build an isolator; usually easier solutions
![Page 58: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/58.jpg)
Interfacing with the Computer
• Tricky!!!
• High power load might require a separate AC circuit
• Many different I/O paths
![Page 59: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/59.jpg)
Common I/O schemes
• “Soundblaster”-type cards– Almost always unbalanced– Treat like any other unbalanced I/O
• Firewire Interfaces (MOTU 828, etc.)– Firewire grounds to the computer– Must then consider the computer part of the
grounding topology
![Page 60: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/60.jpg)
Computer I/O Cont’d
• Cable Modem– Ethernet interfaces usually won’t link grounds– USB interfaces can link computer to cable
ground– Use a Cable Isolator to break the coax ground
• Many other I/Os possible
• You’ll need to experiment
![Page 61: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/61.jpg)
Final Sidebar: Impedance
Too complex to cover here Basically, impedance is like a
frequency-dependent resistance Really good CMR requires I/O circuits
with good impedance design
If you want really really low noise, read up on impedance
![Page 62: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/62.jpg)
Grounding References
http://www.epanorama.net/documents/groundloop/
http://www.equitech.com/articles/articles.html http://www.rane.com/note151.html http://
www.dself.dsl.pipex.com/ampins/groundloops/grndloop.htm
![Page 63: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/63.jpg)
Cabling References
http://www.jensen-transformers.com/apps_wp.html
http://www.rane.com/note110.html
![Page 64: Grounding and Cabling for the Small Studio](https://reader036.vdocuments.net/reader036/viewer/2022062409/568146af550346895db3ca25/html5/thumbnails/64.jpg)
http://www.davidetlinger.comhttp://www.davidetlinger.com
Good luck!!Good luck!!