grundfos ls split case pumpshydro-tech.com.my/.../split-case-pumps-ls-series.pdf · centrifugal...

8
50HZ: 37-2240KW / 60HZ: 75-2500KW GRUNDFOS LS SPLIT CASE PUMPS GRUNDFOS LS SPLIT CASE PUMPS INCREASED PUMP PERFORMANCE AND SYSTEM EFFICIENCY

Upload: others

Post on 08-Apr-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GRUNDFOS LS SPLIT CASE PUMPShydro-tech.com.my/.../Split-Case-Pumps-LS-Series.pdf · CENTRIFUGAL VOLUTE PUMPS. The LS pumps are designed especially for water utility applications and

50HZ: 37-2240KW / 60HZ: 75-2500KWGRUNDFOS LS SPLIT CASE PUMPS

GRUNDFOS LS SPLIT CASE PUMPS

INCREASED PUMP PERFORMANCE

AND SYSTEM EFFICIENCY

Page 2: GRUNDFOS LS SPLIT CASE PUMPShydro-tech.com.my/.../Split-Case-Pumps-LS-Series.pdf · CENTRIFUGAL VOLUTE PUMPS. The LS pumps are designed especially for water utility applications and

HIGH EFFICIENCY

SPLIT-CASE PUMPS

LS SPLIT CASE PUMPS

INTRODUCTION

GRUNDFOS LS LONG-COUPLED, HORIZONTAL

SPLIT-CASE, DOUBLE SUCTION PUMPS,

ARE SINGLE-STAGE, NON-SELF-PRIMING,

CENTRIFUGAL VOLUTE PUMPS.

The LS pumps are designed especially for water utility applications and manufactured

according to the highest Grundfos quality standards. These high efficiency pumps have

a wide efficiency range and very low NPSHr, which ensures safe and economic operation

even when the actual flow deviates from the designed duty point.

APPLICATIONS

IRRIGATION:

WATER SUPPLY:

Page 3: GRUNDFOS LS SPLIT CASE PUMPShydro-tech.com.my/.../Split-Case-Pumps-LS-Series.pdf · CENTRIFUGAL VOLUTE PUMPS. The LS pumps are designed especially for water utility applications and

Lorem ipsum dolor

sit amet igirur

Grundfos LS pumps are in-line design with a radial

suction port and radial discharge port. The flanges are

in accordance with DIN standard. Pump performance

is in accordance with ISO9906 G2.

High efficiency

LS pumps have a very high efficiency, not only at the

rated flow but also within a wide flow range. The

pump retains high efficiency even when the actual

flow deviates by +/-20% of rated flow. The feature

enables the system to operate at high efficiency

when pumps have to operate in parallel, which fits

precisely the specific application at the pumping

station, variable duty points and wide demands for

flow range.

Double volute design

The compensated double-volute design virtually

eliminates radial forces on the shaft and ensures

smooth performance throughout the entire operating

range.

Low NPSHr

NPSHr of the LS pumps at rated point is about 2m-5m

and this fits most customer demands. In addition,

Grundfos provides customised solutions for special

requirements.

QUALITY DESIGN AND VERSATILE

Page 4: GRUNDFOS LS SPLIT CASE PUMPShydro-tech.com.my/.../Split-Case-Pumps-LS-Series.pdf · CENTRIFUGAL VOLUTE PUMPS. The LS pumps are designed especially for water utility applications and

Wear ringReplaceable wear ring design helps to solve the

efficiency drop problem after long-term operation.

The wear ring can be made from different materials

according to customer requirements and the

application.

Shaft and shaft sleeveThe strength and stiffness of the shaft are strictly

calculated to withstand the stress under the

harshest operating conditions. Replaceable sleeves

protect the shaft from erosion and corrosion.

Pump casingThe split-casing enables maintenance of rotating

parts without disturbing the pipe lines.

WHAT MAKES THE LS PUMP SO GOOD

THE DETAILS

Page 5: GRUNDFOS LS SPLIT CASE PUMPShydro-tech.com.my/.../Split-Case-Pumps-LS-Series.pdf · CENTRIFUGAL VOLUTE PUMPS. The LS pumps are designed especially for water utility applications and

Bearing HousingThe bearing sleeve design makes maintenance easier.

The independent bearing housing design enables the

maintenance without interfering pump casing and

bearing sleeve design makes service even easier

BearingHeavy duty bearing design is for the most

severe environments, with the rated life span

50,000 hours.

Compensated double volute designThe compensated double-volute design virtually

eliminates radial forces on the shaft and ensures

smooth performance throughout the entire

operating range.

ImpellerThe hydraulic design balances the axial force and radial force, decreases the

vortex and recirculation in the volute, widening the high efficiency range,

and also meets the low NPSH requirement at high flow. All this ensures

reliable operation under the entire performance range, matching the water

supply demands.

Page 6: GRUNDFOS LS SPLIT CASE PUMPShydro-tech.com.my/.../Split-Case-Pumps-LS-Series.pdf · CENTRIFUGAL VOLUTE PUMPS. The LS pumps are designed especially for water utility applications and

PUMP CONFIGURATIONS

Standard configuration Optional configuration

Pump casing Cast iron Ductile cast iron / Stainless steel

Impeller Stainless steel Bronze / Duplex stainless steel

Shaft Stainless steel Duplex stainless steel

Sleeve Stainless steel Bronze

Wear ring Bronze Cast iron / Stainless steel

Shaft seal Mechanical shaft seal Stuffing box

Flushing line Stainless steel Bronze / Teflon

Low voltage motor efficiency class

(up to 375 kW)IE2 IE3

High voltage motor 6 kV, 10 kV –

Pump direction of rotation Clockwise (CW) seen from shaft endCounter clockwise (CCW) seen from

shaft end

LS PUMP DATA

Computational fluid dynamics

The LS pump’s hydraulic components are

designed using advanced Computational fluid

dynamics (CFD) simulations and the expertise

built up by Grundfos over many years. At

Grundfos, we use CFD simulations to minimise

the risks and cost and time overruns with the

design. This is done by:

1. Improving the flow system design

2. Identifying critical flow issues and the cause

of existing problems

3. Reducing the cost comparing with the

investment for physical modelling

GRUNDFOS USES A RANGE OF SOLUTION TOOLS THAT RESOLVE ISSUES ALREADY AT THE DESIGN STAGE, AND THAT INCREASE PUMP PERFORMANCE AND SYSTEM EFFICIENCY WHEN IN OPERATION, OPTIMISING YOUR WATER SUPPLY.

SOLUTION TOOLS

FOR OPTIMISED WATER SUPPLY

Page 7: GRUNDFOS LS SPLIT CASE PUMPShydro-tech.com.my/.../Split-Case-Pumps-LS-Series.pdf · CENTRIFUGAL VOLUTE PUMPS. The LS pumps are designed especially for water utility applications and

Performance area for the LS Split Case Pumps 50 Hz

Performance area for the LS Split Case Pumps 60 Hz

Suction port : DN450 - DN1200

Discharge port: DN300 - DN800

Operation pressure: 10 or 16 bar

Max. hydraulic efficiency: 91.5 %

Motor power (50 Hz): 37 - 2240 kw

Flow (Q): 1,000 - 12,000 m3/h

Head: 8 - 165 m

Liquid temperature: 0 - 100° C

Variant delivery type

LS PUMP DATA

50 Hz200

Head (H)

150

120

100

80

60

50

40

30

20

15

10

5

5 x 100 1 x 1000 1 x 100007 1.5 1.5 Flow (Q)2 3 4 6 8

60 Hz250

200

Head (H)

150

120

100

80

60

50

40

30

20

15

10

5 x 100 1 x 1000 1 x 100007 1.5 1.5 Flow (Q)2 3 4 6 8

Page 8: GRUNDFOS LS SPLIT CASE PUMPShydro-tech.com.my/.../Split-Case-Pumps-LS-Series.pdf · CENTRIFUGAL VOLUTE PUMPS. The LS pumps are designed especially for water utility applications and

GRUNDFOS Holding A/SPoul Due Jensens Vej 7DK-8850 BjerringbroTel: +45 87 50 14 00www.grundfos.com

Th

e n

am

e G

run

dfo

s, t

he

Gru

nd

fos

log

o, a

nd

be

th

ink

inn

ova

te a

re r

eg

iste

red

tra

de

ma

rks

ow

ne

d b

y G

run

dfo

s H

old

ing

A/S

or

Gru

nd

fos

A/S

, De

nm

ark

. All

rig

hts

re

serv

ed

wo

rld

wid

e.

98

86

266

0/0

215/

WA

TER

UT

ILIT

Y/11

732-

D&

I