GSM ALARM SYSTEM

ELDES EPIR

Page 2: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

User Manual v.1.2

Safety instructions

Pleasereadandfollowthesesafetyguidelinesinordertomaintainsafetyofoperatorsandpeo-ple around:

• AlarmsystemELDESEPIR(laterreferencedassystemordetector)hasradiotransceiveroperating in GSM850, GSM900, GSM1800 and GSM1900 bands.

• Don’tusethesystemwhereitcanbeinterferewithotherdevicesandcauseanypoten-tial danger.

• Don’tusethesystemwithmedicaldevices.• Don’tusethesysteminhazardousenvironment.• Don’t expose the system tohighhumidity, chemical environmentormechanical im-

pacts.• Don’tattempttopersonallyrepairthesystem.Anysystemrepairsmustbedoneonlyby

qualified, safety aware personnel

Thesystemmustbepoweredbypowersupplysourceshouldnotexceed15VApowersupplywhichmustbeapprovedbyLSTEN60950-1standard

Anyadditionaldevice(computer,sirenandetc.)connectedtotheELDESEPIRsystemmustbepoweredupbyaLSTEN60950-1approvedsupply.

External power supply can be connected to AC mainsonlyinsideinstallationroomwithautomat-ic2-polecircuitbreakercapableofdisconnectingcircuitintheeventofshortcircuitorover-currentcondition.Opencircuitbreakermusthaveagapbetweenconnectionsofmorethan3mm.

Mainspowermustbedisconnectedbeforeanyinstallationortuningworkstarts.Thesystem installation or maintenance must not be done during stormy conditions.

Thesystemmustbeusedonlywithapprovedback-upbatterytoavoidfireorexplo-sionhazards. Special caremustbe takenconnectingpositiveandnegativebatteryterminals.

Electrical socket fromwhich thesystem ispoweredmustbe inaneasilyaccessibleplace.

Phase

AC 230V50 Hz/DC 15V

USB cable

Null

PE

EPIR

Page 3: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

EN

Copyright©“ELDESUAB”,2010.Allrightsreserved

Itisnotallowedtocopyanddistributeinformationinthisdocumentorpasstoathirdpartywithoutadvancedwrittenauthorizationby“ELDESUAB”“ELSDESUAB”reservestherighttoupdateormodifythisdocumentand/orrelatedproductswithoutawarning.Hereby,ELDESUABdeclaresthatthisGSMAlarmSystemELDESEPIRisincompliancewiththeessentialrequirementsandotherrelevantprovisionsofDirective1999/5/EC. Thedeclarationofconformitymaybeconsultedatwww.eldes.lt/ce

Thedeviceispoweredbyabackupbattery.Thedeviceisswitchedoffbyunpluggingexternal electrical power supply anddisconnectingbattery connectorwhich is ac-cessed by opening device frame cover.

FuseF1type-C1S2.5A.Blownfusecannotbereplacedbytheuserandthereplace-mentfuseshavetobeexactlythesameasindicatedbythemanufacturer.

IfyouuseIsecurityclasscomputerforsettingtheparametersitmustbeconnectedtoearth.

WARNING:inordertoavoidfireorexplosionhazardsthesystemmustbeusedonlywithapprovedback-upbattery.Specialcaremustbetakenwhenconnectingpositiveand negative battery terminals

TheWEEE(WasteElectricalandElectronicEquipment)markingonthisproduct(seeright)oritsdocumentationindicatesthattheproductmustnotbedisposedoftoget-herwithhouseholdwaste.Topreventpossibleharmtohumanhealthand/ortheenvi-ronment,theproductmustbedisposedoninanapprovedandenvironmentallysaferecyclingprocess.Forfurtherinformationonhowtodisposeofthisproductcorrectly,contact thesystemsupplier,or the localauthority responsible forwastedisposal inyour area.

Page 4: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

22

Limited LiabilityThebuyermustagreethatthesystemwillreducetheriskoffire,theft,burglaryorotherdan-

gersbutdoesnotguaranteeagainstsuchevents.“ELDESUAB”willnottakeanyresponsibilityregardingpersonalorpropertyorrevenueloss

whileusingthesystem.“ELDESUAB”liabilityaccordingtolocallawsdoesnotexceedvalueofthepurchasedsystem.“ELDESUAB”isnotaffiliatedwithanyofthecellularprovidersthereforeisnotresponsiblefor

thequalityofcellularservice.

Manufacturer WarrantyThesystemcarriesa24-monthwarrantybythemanufacturer“ELDESUAB”.Warrantyperiodstartsfromthedaythesystemhasbeenpurchasedbytheenduser.Thewar-

rantyisvalidonlyifthesystemhasbeenusedasintended,followingallguidelineslistedinthemanualandwithinspecifiedoperatingconditions.Receiptmustbekeptasaproofofpurchasedate.

Thewarrantyisvoidedifthesystemhasbeenexposedtomechanicalimpact,chemicals,highhumidity,fluids,corrosiveandhazardousenvironmentorotherforcemajeurefactors.

Package content:1. ELDES EPIR ............................................................................................. qty. 12.PowerSupply. ........................................................................................qty. 13. ELDES EPIR User Manual ....................................................................qty. 14.MicroUSB-USBcable ........................................................................... gty. 1

About User ManualThisdocumentdescribesalarmsecuritysystemELDESEPIRinstallationandoperation.ItisveryimportanttoreadUserManualbeforestartusingthesystem.Aquickstartguide is located infirst twochapters.Chapter3and4describeadditional systemcapabilities.

Page 5: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

USERMANUALV.1.2 23

EN

CONTENT

1. General Information

1.1 Functionality ................................................................................................................................................ 24 1.2 Operationdescription .............................................................................................................................. 24 1.3 Technicalspecifications .......................................................................................................................... 25 1.4 Main functions ........................................................................................................................................... 25 1.5 System installation .................................................................................................................................... 26

2. System pre-operation and essential control commands

2.1 SelectingdevicelanguageandverificationofSMScentralnumber ...................................... 28 2.2 Passwordchange ...................................................................................................................................... 29 2.3 Usernumbers .............................................................................................................................................. 29 2.3.1 SavingorChangingnumbers .............................................................................................. 29 2.3.2 Verificationofsavednumbers .............................................................................................. 30 2.3.3 Deletionofsavednumbers................................................................................................... 30 2.4Dateandtimesettings ............................................................................................................................... 31

3. Additional system capabilities

3.1 Renaming security zones..................................................... ................................................................... 32 3.2 SystemandZonestatus .......................................................................................................................... 32 3.3 Exit time-out configuration.................................................................................................................... 32 3.4 Info on status SMS ............................................................. ....................................................................... 33 3.5 Blockingunknownincomingnumbers............................................................. ................................ 34 3.6 Externalpowersupplycontrol. ............................................................................................................. 34 3.7 EnablingRemoteMicrophonelistening .......................................................................................... 34 3.8 SMS message delivery to multiple users ........................................................................................... 35 3.9 SMS message informing about system arming/disarming ....................................................... 35 3.10 Setting detector sensitivity level .......................................................................................................... 35 3.11.UsingWirelessDevicesinEPIR868System ....................................................................................... 36

4. Appendix

4.1 Restoring default parameters .............................................................................................................. 37 4.2 ELDESConfigToolconfigurationsoftware ........................................................................................ 37 4.3 Replacing back-up battery ................................................................................................................... 37 4.4 Technicalsupport ..................................................................................................................................... 38

Page 6: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

24

1. General Information

1.1 FunctionalityELDESEPIR–microcontrollerbasedsecuritysystemforhouses,cottages,countryhomes,garagesandotherbuildings.

Thesystemcanbeusedinfollowingapplications:• Propertysecurity• Mains230VpowerstatuswithSMSmessage• Remotelisteningofwhatishappeninginthesecuredpropertywithbuiltinmicrophone

Alsocapableofinforminguseraboutmains230VpowerstatusovercellularGSMnetwork.

1.2 Operation DescriptionSecurityalarmsystemELDESEPIRworkswithGSMnetwork.Thesystemisarmedordisarmedbyacall

fromyourmobilephonewhichdoesn’tincuranycost.ToarmordisarmthealarmsystemtheuserhastocalltothenumberoftheSIMcardinsertedinELDESEPIRdevice.Beforedoingthisitisnecessarytochangethedefaultpasswordandenteratleastoneuser.

Whenalarmsystemnumberhasbeendialedandringingisdroppedafterthreecallsignals–meansthesystemwassuccessfullyarmed.Ifringingisdroppedafteronlyonecallsignal–systemdisarmed.Theusershouldwaituntilthesystemdropscallsautomatically.

TheuserlistedasNr.1getsshortSMSmessageeachtimethesystemissuccessfullyarmedordis-armed.Whensystemisarmedviaphonecall,thereis15seconddelaybeforeactivation,meantforleavingpremises.Thetimedelayisuserconfigurableparameter(seechapter3.3).Redlightemittingdiodeindica-tor(LED)locatedondetectorlensewillstarttoblinkinformingthattimedelayhasbeenengagedandusermustleaveroom.Theredlightgoesoffupontime-outdelayexpirationandsystemisengaged.

Whendetectorisdisarmedandmotionisdetectedintheroom,LEDonthelensewillbeturnedonshortly.Whendetectorisarmedandupondetectionofmotion,systemwillsendSMSmessageuntilsuc-cessfuldeliveryandringpreprogrammednumbersuntiluserpicksuporcallexpires.Ifuseranswersthecall,remotemicrophonegetsactivatedforlistening.

SMSmessagecanbesenttoallpreprogrammedusers(seechapter3.8formoredetails).Thesystemwillautomaticallyswitchtoback–upbatterysupplyincaseofmainspowerfailure,and

usergetsSMSwarningmessage.SMSmessagewillalsonotifywhenmainspowerisrestoredorback-upbatteryisabouttogetdischargedandsystemwillbeswitchedoff.

Theusercanalsoinquirethesystemaboutsystemstatus,powersupplystatus,networkqualityaswellasconnectandlistenthrougharemotemicrophone.

Thesystemwill ignorerequestscomingfromunknowntelephonenumberorSMSmessagewithwrongpassword.WithcorrectpassworduserhasthecapabilitytoaccesssystemmanagementfromanyGSMphone(notnecessarypre-programmed).Seemoredetailsinchapter3.5.

SecuritysystemELDESEPIR868(ELDESEPIRversionwithinstalled868MHzradiotransmitter-receiver)can also operate as an access point for wireless ELDES products: PIR sensors EWP1, sirens, magnetic door/windowsensorsEWD1orexpansionmodulesEW1andEW2.UsingELDEREPIR868youcanaccessupto16wirelessdevicesatatime.YoucanfindmoreinformationaboutusingthesedevicesandchainingthemtoEPIR868inthemanualsoftheseproducts.

Page 7: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

USERMANUALV.1.2 25

EN

1.3 Technical SpecificationsElectrical and mechanical specifications

SupplyVoltage

Back-upBatteryvoltage,capacity 8.4V;150-250mAh

Back-upBatterytype Ni-Mh

GSM modem frequency 850/900/1800/1900Mhz

Dimensions 104x60x33mm

Operating temperature range -10…+40oC

Back-upbatteryoperatingtime upto6hours

Detection angle 90°

Supported protocol CONTACT ID

Maximum motion detection range 10 meters

Radio transimtter-receiver frequency* 868Mhz

Radio communication range* upto30minpremises;upto150minopenareas

Maximum number of wireless devices* 16

1.4 Main FunctionsShort description of main functions:

1. ELDESEPIRholderusedforwallfixing2. DetectorlensewithLEDindicatorlight3. Power supply socket4. Power supply5. Power supply connector6. Buttontorestoredefaultparameters7. Microphone8. Holderfixingplace9. BackupBattery10. Micro-USBconnector11. SIMcardholder12. Motiondetector13. TAMPER button14. Modulewithintegrated868Mhz radio transmitter-receiver*

BACK SIDE INSIDE LOOK

1

10

4

2

8

10

11

14

12

136

3

5

9

7

11-15V 500 mA max

*usedonlyinELDESEPIR868system.

Page 8: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

26

1.5 System installationThesystemshouldbe installed indoors.Choose locationwhereunauthorizedentry ismost

likely.

To avoid fault alarms, avoid installing in following locations:• locatinglenstowardsdirectsunshine,e.g.facingwindows• neardeviceswithhightemperaturefluctuations,e.g.fireplaceorheatingboiler• placeswithincreaseddustorairflowtraffic• metalorshieldedwallwhereGSMconnectionmightbelost

PlaceSIMcardinthemobilephoneandmakesurethatSIMcardPINcodeisdisabledbyfollow-ingappropriatemenus.SIMcardshouldnothaveanyremainingSMSmessages.

RECOMMENDATION

ItisworthtochoosethesameGSMcellularproviderasmostusersuseassuringfastandreli-ableSMSmessagedeliveryandphonecallconnection.

RECOMMENDATION

To increase system reliability, it is recommendednot touseprepaid SIM cards.The systemwould fail to send any messages upon depletion of prepaid account. Also it is recommended to disable call forwarding and voice mail.

Page 9: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

USERMANUALV.1.2 27

EN

* Removeupperhalfofthedevice(withdetectorlense)byturningoffthescrew.SIMcardshouldberespectivelyinsertedtothecorrespondingholder(see1.4chapter).

6.Thesystemstartsin1-2minutes.WhenLEDisoff,moveyourhandinfrontofELDESEPIRlenseandwatchthesystemdetectingmotionandturningonLEDforfewseconds.IfLEDindicatorisblinkingfast(fewtimesasecond),couldbethatSIMcardinnotinsertedproperlyorPINcodehasnotbeendisabled.

1. Fixtheholdertothewall

3. Plug power supply connector

5. Plug power supply into mains socket

2. InsertSIMcardwithPINcodedisabled

4. Place ELDES EPIRintotheholder

Page 10: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

28

2. System pre-operation and essential control commands

VERY IMPORTANT!!!

Underscoresymbol‘_’inthismanualisusedtorepresentspace.WhenwritingSMSmessages,everyunderscoresymbolshouldbereplacedbysinglespacesymbol.XXXX–meanspassword.Don’tleaveanyspaceatthebeginningandtheendofthemessage.

TosetELDESEPIRsystemparameterseasierandquickeryoucanusethecomputer,USBcableandconfigurationprogramELDESEPIRConfigTool.Youcanreadmoreinchapter4.2.

2.1 Selecting device language and verification of SMS central numberThelanguageinwhichthedevicecommunicateswiththeusercanbechosenbeforechangingfactorydefaultpassword.Tochangethelanguageinthesystemthatisalreadyconfiguredresetdefaultset-tings as described in 4.1 appendix.

SendSMSmessagewiththerequiredlanguagecodetothenumberoftheSIMcardinsertedinELDESEPIR.

E.g., if you want to set the English language send the following SMS message: EN

30-60secondslateryoushouldgetanSMSmessage:„Englishlanguageconfirmed.“Gotochapter2.2uponreceptionofthismessage.

OtherwisecheckfornetworkconnectionandcallELDESEPIRsystemfromyourmobileandwaituntilthesystemdropsthecall.YoushouldgetanSMSmessageaskingtochangedefaultpassword.Ot-herwisecheckfornetworkconnectionandchangeSMScentralnumber.

SMScentralnumberissavedinSIMcard,thereforeifSIMcardhasbeenusedtosendSMSmessa-geswithamobilephone,thenyoudon’t’needtochangeSMScentralnumber.OftenSMScentralnumber is already saved in SIM card by cellular operator.

Possible languages

lithuanian LT

russian RU

english EN

estonian EE

latvian LV

czech CZ

german DE

finnish FI

french FR

spanish ES

slovak SK

icelandic IS

Page 11: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

USERMANUALV.1.2 29

EN

Central number can be entered by sending SMS message:

XXXX–isapassword.Defaultpasswordisfourzeros:0000.SMScentralnumberisprovidedbycellularnetwork provider.

Example: 0000_SMS_+37069899992

MessageshouldbesenttothenumberofSIMcardwhichisplacedintothesystem.Ifallwentcorrect,thesystemwillsendamessage:SMS central number has been successfully changed to +37011111111

2.2 Password changeAll SMS commands startwith apassword, sopleasememorize itwell. Manufacturer default password is four zeros 0000, which is necessary to change. Manufacturer default password can be changedbysendingSMSmessagetoELDESEPIR:

To replace your password, send SMS message:

XXXX–anyfourdigitnumberexceptfourzeros.Non-numericalcharacterslikedots,colons,spacesarenotallowed.YYYY–oldsystempassword.

Defaultmanufacturerpasswordcanberestored,seechapter4.1formoredetails.

2.3 User numbersSystemELDESEPIRallowstopre-programuptofivedifferentmobilenumberswhichwillhave

access to and controls the system.NumberNR1 ismandatorywhileothers canbe skipped.Allnumbersmustbeenteredstartingwithinternationalcountrycode.E.g.nationalcodeforLithuaniais370,UK–44.Numbersshouldbeenteredbasedonpriority,sincethesystemwilltrytocontactfirstenterednumberandincaseoffailurewillfollowwithsecondandsoon.

0001 PSW 1111

XXXX_SMS_+37011111111

0000_PSW_XXXX

YYYY_PSW_XXXX

Page 12: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

30

2.3.1 Saving or Changing numbers

SendSMSmessagewithtexttoELDESEPIR:

Onesshouldbereplacedwithusernumbers.Numbersdon’thavetobeenteredallorinsequentialorderrightaway.E.g.usecanen-terfirstandfourthnumberbysendingfollowingSMSmessage:

Or individually one number at a time:

Numbers can be changed sameway as described above. New numberwill overwrite old one,thereforenoerasingisnecessary.

2.3.2 Verification of saved numbers

Toinquirethesystemaboutpre-programmednumbers,sendSMSmessage:

Thesystemwillreplywithallpre-programmednumbers.

2.3.3 Deletion of saved numbers

Pre-programmed numbers can be erased by sending SMS message withnumberstobeerased.

ToeraseNR2sendfollowing:

ThesystemwillnotallowerasingfirstnumberNR1.Itcanonlybechanged.

XXXX_NR1:37011111111_NR2:37011111111_NR3:37011111111_NR4:37011111111_NR5:37011111111

XXXX_NR1:37011111111_NR4:37011111111

XXXX_NR3:37011111111

0001 NR1: 37011111 111

0001 HELPNR

0001 NR2:DEL

XXXX_HELPNR

XXXX_NR2:DEL_NR3:DEL_NR4:DEL_NR5:DEL

Page 13: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

USERMANUALV.1.2 31

EN

2.4 Date and time settingsItisimportanttosetcorrectdateandtime,sothatthesystemcansendreportsatspecifiedtimes.Date and time can be set by sending following format SMS message: WhereMMMM–meansyear,mn–month,dd–day,hh–hour,mi–minutes

E.g. 0000_2009.01.01_14:15

0001 2009.01. 01 14:15

XXXX_MMMM.mn.dd_hh:mi

Page 14: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

32

3. Additional system capabilities

3.1 Renaming security zonesManufacturerinitiallysetfollowingzonenames:Z1-Motion.Userisfreetochangeanyofthesenameskeepinginmindthatnamescannotbesameormatchsystemcommands.ZonenamescanbechangedwithfollowingSMSmessage:

Zonenamescanhaveupto14characters.

3.2 System and Zone statusTo find out current zone names, settings and status, send SMS message

Thesystemwillreply,e.g.System is armed/disarmed Z1:MOTION:ON/OFF

ON- means enabled. OFF- disabled

ATTENTION: InthesystemofELDESEPIR868youcanreceiveinformationaboutupto32ad-ditionalzonesinputsand/orupto32additionalcontrolledoutputs(itdependsonhowmanywirelessdevicesisaddedtothesecuritysystem).InthiscasesystemwillsendareplybySMSmessages,ineachofthemplacinginformationabout4activezonesinputsor/andcontrolledoutputs(itwontsendinformationaboutinactivezonesandcontrolledoutputs).Forexample,ifthereisadded1expansionmoduleEW1(with2inputsand2outputs)tothesystem,admin-istratorwillreceive2SMSmessagesabout3zonesand2controlledoutputs.

3.3 Exit time-out configurationWhensystemisarmed,theusershouldleavepremiseswithinspecifiedtime(manufacturerdefault15seconds).Duringthisperioddetectorignoresmotion.Runningtime-outisindicatedbyblinkingLED(onceasecond).Time-outperiodcanbeconfiguredwithSMSmessage:

WhereSSO–exittime-outinseconds.

Thereisnotime-outifperiodissetto0.

0000_Z1:NewZoneName0001 Z1: passage

XXXX_STATUS

XXXX_INOUT:SSO 0001 INOUT:30

Page 15: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

USERMANUALV.1.2 33

EN

0001 Z1: passage

0001 INOUT:30

3.4 Info on status SMSSecurity systemEPIR canbe inquired at any timeabout its status, signal strength, zone status.At the same time systemcanbe tested. If SMS responsemessage is received,means system isfunctioning properly.ThisisalsousefulforuserswithprepaidSIMcards.ItcanbecheckedwhetherSIMcardhasenoughremaining balance for sending SMS. Send SMS message:

TheresponseSMSmessagewillbereceived,e.g.2008.08.07 11:15 System armed/disarmed Signal Strength Fair. Z1:OK/ALARMWhereOK– if zonehasnotbeenactivated,ALARM– ifbeenac-tivated

Bydefault,thisstatusSMSmessagewillbesentdailyat11:00inthemorning.TheseparameterscanbeconfiguredwithSMSmessage:

PP–messageperiodindays,validvalues[00–10]VV-timewhenmessageissent,validvalues[00–23] E.g XXXX_INFO:01:10, meansthatstatusmessagewillbesentevery1dayat10:00.IfPPvalueis0,andVVintherangeof[1-23],thenperiodicstatusmessageswillbesentmultipletimesperday,withperiodbeingspecifiedasVVtime.

E.g. XXXX_INFO:0.2, meansthatstatusmessagewillbesentevery2hours.

To disable periodic status messages, send SMS:

The statusmessageswill not be sent until enabling or restoringdefault parameters.

XXXX_INFO0001 INFO

XXXX_INFO:PP.VV

XXXX_INFO:00.00

0001 INFO: 01.10

0001 INFO: 0.2

0001 INFO: 00.00

Page 16: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

34

3.5 Blocking unknown incoming numbersBydefaultELDESEPIRcanbecontrolledfromanyofthepre-programmednumbersNR1..NR5.Butusercanaccessthesystemandcontrolparametersfromanynumberaslongaspasswordis know.Toenablethisfeature,sendSMSmessage:

Todisablethisfeature,sendSMSmessage:

3.6 External power supply controlThesystemELDESEPIRwillreporteverytimemains230Vpowersupplyfailsorrecovers.Insomeremoteplaceswheremainspowersupply isunreliable, thesystemcanbeconfiguredto ignorethesechanges.SendSMS:

Or it can be enabled by SMS message:

3.7 Remote Microphone listening To be able to listen what is going on in remote house can be done in two different ways:

1. Whenalarmhasbeenactivated,thesystemwillringpre-programmednumbersandusercananswerthecall.Remotemicrophonewillbeenabledforlistening.

2. BysendingSMSmessage

ThesystemwillringthesenderofformerSMS,anduponansweringthecall,usercanlistentoanysoundsinthebuilding.Thephonecallmustbeansweredwithin20secondsother-wisethesystemwillstoptryingandreturntopreviousstate.

XXXX_STR:ON

XXXX_STR:OFF

XXXX_M:OFF

XXXX_M:ON

XXXX_MIC

0001 STR: ON

0001 M: OFF

Page 17: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

USERMANUALV.1.2 35

EN

3.8 SMS message delivery to multiple usersUponactivatedalarm,SMSmessagesarerepeatedlysentuntilfirstsuccessfuldeliverytooneoftheusers.SystemstartswithNR1,andifdeliveryfails,followswithNR2,etc.ItisalsopossiblethatSMSmessagewillbesenttoallrecordedusers.

Toenablethisfunction,sendSMSmessage:

Todisablethisfunction,sendSMSmessage:

3.9 SMS message informing about system arming/disarmingBydefaulttheuserNR1willreceiveashortmessageeverytimesystemisarmedordisarmed.Todisablethisfunction,sendSMSmessage:

Tore-enablethisfunction,sendSMSmessage

3.10 Setting detector sensitivity levelThemanufacturerhassetoptimaldetectorsensitivity level.However, insomecasesthesystemisinstalledinwindypremiseswheretheairflowcancausefalsealarms.Insuchcasessensitivitylevelcanbereduced.InordertoincreaseorreducemotiondetectorsensitivitytheuserhastosendthefollowingtextmessagetothesystemELDESEPIR:

whereXXisatwo-digitnumberthatcanbe[20-99].Factorydefaultvalueis40.Thegreaterthenumbervalue,thelowerdetectorsensitiv-ity level.InordertofindoutthesetsensitivityleveltheusershouldsendthefollowingSMSmessage:XXXX_LEVEL

0001 STR: ON

0001 M: OFF

XXXX_SMSALL:ON

XXXX_SMSALL:OFF

XXXX_MASTER:OFF

XXXX_MASTER:ON

0001 LEVEL:XX

XXXX_LEVEL:XX

Page 18: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

36

3.11. Using Wireless Devices in EPIR868 System

ATTENTION: bindingofwirelessdevicesissupportedonlybyELDESEPIR868.

SecuritysystemELDESEPIR868canbeexpandedbyconnectingadditionalwirelessELDESdevices:• PIRsensorsEWP1(motiondetectors).Itallowstoexpandsecuredterritoryupto16additionalsecurityzones;

• expansionmodulesEW1with2inputsand2programmableoutputs.Itisusedforattachingmoredevices(variousdetectors,sirens)tothesecuritysystem.

• expansionmodulesEW2with4inputsand6programmableoutputs.Itisusedforattachingmoredevices(variousdetectors,sirens)tothesecuritysystem.

• wirelesssirens;• wirelessmagneticdoor/windowsensorsEWD1;

Itispossibletoconnectupto16wirelessdevicestothecentralsecuritysystematatime.Maximumdistanceforwirelessconnectionis150meters(inopenareas).Formoreinformationpleasecheckusermanualsofthesedevices.

Page 19: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

USERMANUALV.1.2 37

EN

Page 20: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

38

4. Appendix

4.1 Restoring default parametersTorestoresystemdefaultparameters,removeupperhalfofdevice(withdetectorlense)andcon-nectpowersupply.Thenpressandholdonthebuttontorestoredefaultparameters(seechapter1.4)untilLEDindicatorwillblink5times.Disconnectpowersupply.

4.2 ELDES ConfigTool configuration softwareConfigurationprogramworksonlywithELDESEPIRdevicesstartingwithv2version.Toconfigurethesystemquickerandeasieraswellasusemoresystemcapabilitiesuseconfigurationprogram„ELDESConfigTool”whichcanbedownloadedfromourwebsitewww.eldes.ltBeforeconnectingUSBcabletothecomputerreadELDESConfigTooluserguideavailableintheprogramchapterHELP.

4.3 Replacing back-up battery Normallyrealback-upbatterywilllastatleast2years.Thislargelydependsonsurroundingtem-perature and frequency of mains power disruptions.

To change back-up battery, follow these steps:1. Unplug power supply form mains power2. RemoveELDESEPIRfromholder3. Unplug power supply connector4. RemovescrewlocatedonthebacksideofELDESEPIR5. Open ELDES EPIR enclosure6. Carefullyremoveback-upbattery7. Withonehandholdingback-upbattery,unplugbatteryconnector8. Replacebattery.Usebatterytypeasspecifiedintechnicalspecifications.9. Repeat all steps in inverse order

Page 21: GSM ALARM SYSTEM ELDES EPIR - TRIDIMASGSM ALARM SYSTEM ELDES EPIR User Manual v.1.2 Safety instructions Pleaseead r and follow these safety guidelines in order to maintain safety of

USERMANUALV.1.2 39

EN

4.4 Technical support

Indication Possible reason

Lense indicator OFF · Nomains230Vpower· Power supply connector unplugged· out of coverage or to weak signal.

Indicator is blinking once a second · missing SIM card· PINcodehasn’tbeendisabled· SIM card not active

System does not send any SMS messages and/or does not ring

· SIM card account depleted· Incorrect SIM central number· No network signal· Usernumberisnotprogrammedin(ordisabledaccessfromunknownnumbers)

Received SMS message “IncorrectFormat”

· Wrong syntax· Could be space left in wrong SMS message place· Manufacturerdefaultpasswordnotchanged· Missing user NR1

Ifyourproblemcouldnotbefixedbytheguideabove,pleasecontactyourdistributorormanufac-turertechsupportbyemailsupport@eldes.lt

Moreuptodateinformationaboutyourdeviceandotherproductscanbefoundatmanufacturer’swebsite www.eldes.lt