gson metric imperial norms book
TRANSCRIPT
1
Schedule
of
‘Pure’ Norms
Handbook Date: 26 November 2009
Status: CONTROLLED VERSION DO NOT COPY
Version: 1.2
Author: R Faulkner
2
1. DOCUMENT CONTROL
1.1 Summary
Document Name: PURE Norms manual
Document Reference: Norms 001
Document Status: Draft
1.2 Revision History
Revision Date
Version Author Change References / Summary
16/09/2009 1.0 R Faulkner Final draft
26/10/2009 1.1 P Collins Inc. insulation material factors
26/11/2009 1.2 R Faulkner Inc. metric & imperial tables (not all)
1.2 Distribution
Reviewer Company
Paul Collins EC Harris LLP
Mark Howard EC Harris LLP
Robin Faulkner EC Harris LLP
1.3 Approvals
Name Signature on Approval Date
Paul Collins
Mark Howard
1.4 Related Documents
Document Name Date of Issue / Reference
Author
3
Table of Contents
1 Preface..................................................................................8
1.1 Benefits of Using Norms............................................................................... 8 1.2 Overview of Disciplines Used and Services ................................................. 8
2 Factors ..................................................................................9
3 General Rules and Definitions ..............................................9
3.1 Design Information ......................................................................................10
4 Introduction to the Contracting Methodology ......................10
4.1 Contract Factors..........................................................................................10 4.2 Efficiency Factor..........................................................................................11 4.3 Site Factor...................................................................................................11 4.4 Location Factors..........................................................................................11 4.5 Condition Factors ........................................................................................11 4.6 Material Factors...........................................................................................12 4.7 Application of Factors..................................................................................12 4.8 Constituents of the Selling Rate ..................................................................13
D.1 Scaffolding Norms .........................................................17
D.2.1. Coventional Scaffolding.............................................................................17 D.2.2. System scaffolding ....................................................................................18
E.1 Steel Work Norms..........................................................19
E.2.1 Fabricate & Install Primary and Secondary Steel Items ............................19 E.2.2 Manual & semi-automatic Welding of Primary & Secondary Steel Items ..20 E.2.3 Automatic Welding of Primary & Secondary Steel Items...........................21 E.2.4 Bolting of Primary & Secondary Steel Items..............................................22 E.2.5 Fabricate and Install Outfitting Steelwork Steel.........................................23
FA.1 Static Equipment Norms ................................................24
FA.2.1 Isolate & De-isolate Pipework ................................................................24 FA.2.2 Install / remove manway covers.............................................................26 FA.2.3 Shell Repairs – incl. Welding .................................................................27 FA.2.4 Welding..................................................................................................28 FA.2.5 Furnace & Boilers ..................................................................................29 FA.2.6 Heat Exchangers ...................................................................................30 FA.2.7 Heat Exchanger / Air Cooler – Unbolting & Bolting ................................32 FA.2.8 Air Coolers .............................................................................................33 FA.2.9 Heat Exchangers / Air Coolers...............................................................34 FA.2.10 Columns.................................................................................................35 FA.2.11 Bursting Discs ........................................................................................37 FA.2.12 Relief Valves ..........................................................................................38 FA.2.13 Fire Monitors (Hydrants) ........................................................................39
4
FA.2.14 Hoses (Flanged Connection) .................................................................40 FA.2.15 Hoses (Screwed Connection) ................................................................41 FA.2.16 Hoses > 1m (3ft) (e.o. norm)..................................................................42 FA.2.17 Bellows ..................................................................................................43 FA.2.18 Liquid Pulsation Dampers ......................................................................44 FA.2.19 Plate Packs ............................................................................................44 FA.2.20 Ejectors..................................................................................................45 FA.2.21 Filters .....................................................................................................46
FB.1 Rotating Equipment Norms............................................47
FB.2.1 Single stage pumps ...............................................................................47 FB.2.2 Split horizontal pumps............................................................................48 FB.2.3 Split vertical pumps................................................................................49 FB.2.4 Pump Removal/Refit ..............................................................................50 FB.2.5 Coupling Variations................................................................................51 FB.2.6 Reciprocating dosing pump ...................................................................51 FB.2.7 Miscellaneous pump work......................................................................52 FB.2.8 Fin Fans.................................................................................................54 FB.2.9 Electric Motors .......................................................................................55 FB.2.10 Alignment...............................................................................................55
G.1 HVAC Norms .................................................................56
G.2.1 Square.......................................................................................................56 G.2.2 Circular......................................................................................................58 G.2.3 Spiral Wound.............................................................................................60 G.2.4 Fittings.......................................................................................................61 G.2.5 Equipment .................................................................................................62 G.2.6 Supports....................................................................................................63
H.1 Mechanical Pipework Norms .........................................64
H.2.1 Pipework Fabrication Sch10......................................................................64 H.2.2 Pipework Fabrication Sch20......................................................................65 H.2.3 Pipework Fabrication Sch30......................................................................66 H.2.4 Pipework Fabrication Std wall ...................................................................67 H.2.5 Pipework Fabrication Sch40......................................................................68 H.2.6 Pipework Fabrication Sch60......................................................................69 H.2.7 Pipework Fabrication SchXS.....................................................................70 H.2.8 Pipework Fabrication Sch80......................................................................71 H.2.9 Pipework Fabrication Sch100....................................................................72 H.2.10 Pipework Fabrication Sch120 ................................................................73 H.2.11 Pipework Fabrication Sch140 ................................................................74 H.2.12 Pipework Fabrication Sch160 ................................................................75 H.2.13 Pipework Fabrication SchXXS ...............................................................76 H.2.14 Pipework Erection Sch10.......................................................................77 H.2.15 Pipework Erection Sch20.......................................................................78 H.2.16 Pipework Erection Sch30.......................................................................79 H.2.17 Pipework Erection Std wall ....................................................................80 H.2.18 Pipework Erection Sch40.......................................................................81 H.2.19 Pipework Erection Sch60.......................................................................82
5
H.2.20 Pipework Erection SchXS ......................................................................83 H.2.21 Pipework Erection Sch80.......................................................................84 H.2.22 Pipework Erection Sch100.....................................................................85 H.2.23 Pipework Erection Sch120.....................................................................86 H.2.24 Pipework Erection Sch140.....................................................................87 H.2.25 Pipework Erection Sch160.....................................................................88 H.2.26 Pipework Erection SchXXS....................................................................89 H.2.27 Steam Tracing........................................................................................90 H.2.28 Hydrostatic and Pneumatic testing.........................................................91 H.2.29 Pipework Removal .................................................................................92 H.2.30 Pipework Support Fabrication................................................................93 H.2.31 Pipework Support Erection ....................................................................94
H.3 Pipe size conversion tables ...........................................95
J.1 Electrical & Instrumentation Norms ...............................96
J.2.1 Conduit Installation......................................................................................96 J.2.2 Trunking Installation ....................................................................................97 J.2.3 Tray Installation ...........................................................................................99 J.2.4 Rack installation ........................................................................................101 J.2.5 Supporting Steelwork Fabricate & Install) .................................................102 J.2.6 Supporting Steelwork (Install Only) ...........................................................102 J.2.7 Cable Installation.......................................................................................103 J.2.8 Electrical Accessories Installation .............................................................111 J.2.9 Light Fittings Installation............................................................................112 J.2.10 Electrical Switchgear Installation.............................................................113 J.2.11 Instrument Pipework ...............................................................................115 J.2.12 Instrument Equipment .............................................................................116 J.2.13 Telecomms/CCTV/Security Equipment Installation.................................119 J.2.14 Fire & Gas Equipment Installation...........................................................119 J.2.15 Heat Tracing............................................................................................120 J.2.16 Testing ....................................................................................................121
L.1 Insulation Norms..........................................................122
L.2.1 Base Preformed Section Norms (Mineral Wool)......................................122 L.2.2. Polyisocyanurate Preformed Sections: Vapour Seal (Mastic & Scrim Cloth) 143 L.2.3 Calcium Silicate Preformed Section: up to 24 mil Aluzinc or Aluminium Flat Rolled Casing to Pipework ...................................................................................179 L.2.4 Perlite Preformed Section: up to 24 mil Aluzinc or Aluminium Flat Rolled Casing to Pipework ..............................................................................................194 L.2.5 Glass Rope Spirally Wound To Pipework................................................209 L.2.6 Vessels, Tanks, Columns & Equipment Insulated with Mineral Wool Rigid Slabs or Flexible Mattress....................................................................................210 L.2.7 Vessels, Tanks, Columns & Equipment Insulated with Polyisocyanurate Slabs/Lags: ..........................................................................................................224
M.1 Painting Norms ............................................................229
M.2.1 Grit blast of new & existing surfaces .......................................................229
6
M.2.2 Grit blast to new & existing surfaces (including remedials) .....................230 M.2.3 Wet blast to existing surfaces..................................................................231 M.2.4 Hand Preparation ....................................................................................232 M.2.5 Work Insitu on site to new & existing surfaces – Application by brush or roller 233 M.2.6 Work on site or in a dedicated painting facility – Spray application .........234 M.2.7 Work on site or in dedicated painting facility – Spray application (incl. remedials) ............................................................................................................235
O.1 Cleaning Norms...........................................................236
O.2.1 Vessels & Column Cleaning....................................................................236 O.2.2 Tank Cleaning - Removal of content: pumpable liquid/sludge.................238 O.2.3 Tank Cleaning - Removal of content: non-pumpable liquid/sludge .........239 O.2.4 Tank Cleaning - washing.........................................................................240 O.2.5 Hydro-cutting tank shell...........................................................................241 O.2.6 Pipework Cleaning ..................................................................................241 O.2.7 Floating Head & “U” Tube Exchangers - Bundle Only - Tube Side Only (Int.) 242 O.2.8 Floating Head & “U” Tube Exchangers - Bundle Only - Shell Side Only (Ext.) 245 O.2.9 Floating Head & “U” Tube Exchangers - Shell ........................................248 O.2.10 Fixed Tubesheet Exchangers ..............................................................249 O.2.11 Air Fin Coolers .....................................................................................252
P.1 Tankage Norms ...........................................................253
P.2.1 Cone Roofs & Internal/External Floating Roofs...........253
P.2.1.1 Demolition Work...................................................................................253 P.2.1.2 Roof Plate & Roof Structure Installation...............................................255 P.2.1.3 Roof Manways & Nozzles ....................................................................257 P.2.1.4 Lap Patching (Overplate) .....................................................................259 P.2.1.5 Rim Angle & Associated Work .............................................................260 P.2.1.6 Roof Drain Systems .............................................................................260 P.2.1.7 Stilling Wells.........................................................................................261 P.2.1.8 Roof Support Legs ...............................................................................262
P.2.2 Shell Work ...................................................................263
P.2.2.1 Shell insert plates / doorsheets ............................................................263 P.2.2.2 Lap Patches (Overplate) ......................................................................265 P.2.2.3 Manways & nozzles .............................................................................266 P.2.2.4 Insulation stops & shields ....................................................................271 P.2.2.5 Couplings & valves ..............................................................................271
P.2.3 Bottom Work ................................................................272
P.2.3.1 Demolition & Removal Work ................................................................272 P.2.3.2 Tank Bottom Fabricate & Install – Annular Plate Design .....................273 P.2.3.3 Tank Bottom Fabricate & Install - New Annular Plate Design ..............274 P.2.3.4 Tank Bottom Fabricate & Install - New Sketch Plate Design ...............276
7
P.2.3.5 Lap Patching (Overplate) .....................................................................278 P.2.3.6 Pads.....................................................................................................279 P.2.3.7 Sumps..................................................................................................280 P.2.3.8 Tank Bottom Beds & Linings................................................................281 P.2.3.9 Preparation for Inspection....................................................................282
P.2.4 Ancillary Work..............................................................283
P.2.4.1 Demolition and Removal Work.............................................................283 P.2.4.2 Re-installation of Existing Components ...............................................284 P.2.4.3 Fabrication & Installation of New Components ....................................285 P.2.4.4 Ladder Assemblies ..............................................................................286 P.2.4.5 Testing .................................................................................................286 P.2.4.6 Tank Builders Scaffold .........................................................................286
P.2.5 Tank Jacking................................................................286
P.2.5.1 Tank Jacking........................................................................................286 P.2.5.2 Welding................................................................................................287
Q.1 Civil & Building Norms .................................................288
Q.2.1.1 Groundworks........................................................................................288 Q.2.1.2 Piling ....................................................................................................295 Q.2.1.3 Concrete Work.....................................................................................297 Q.2.1.4 Steelwork .............................................................................................308 Q.2.1.5 Masonry ...............................................................................................313 Q.2.1.6 Specialist Linings .................................................................................319 Q.2.1.7 Surface Treatments .............................................................................323 Q.2.1.8 Drainage ..............................................................................................326 Q.2.1.9 Roads, Paving & Fencing ....................................................................337
Q.2.1 Building Norms...........................................................340
Q.2.2.1 Demolitions & Alterations.....................................................................340 Q.2.2.2 Roof Decking & Wall Cladding.............................................................342 Q.2.2.3 Lining / Partitions .................................................................................348 Q.2.2.4 Doors & Windows ................................................................................351 Q.2.2.5 Surface Finishes ..................................................................................354
R.1 Fireproofing Norms......................................................358
S.1 Safety & Loss Prevention Norms.................................359
8
1 Preface The Man-hour Norms Productivity Strategy provided by EC Harris LLP is part of the overall portfolio of services targeted at helping clients deliver increased asset contribution through improving and increasing the outputs and productivity of the assets, in combination with decreasing the total cost of ownership. The norms are strictly for estimating the man-hours content of the work being performed and do not cover any material costs or allowances. The norms have been measured and compiled using the SMMIEC standard methodology, with any deviations noted within the appropriate sections. Whilst the norms are reflective of the work content they are set at a level that is challenging and an appropriate contract factor will need to be applied as discussed under the contracting section of this document.
1.1 Benefits of Using Norms The benefits delivered through the use of the Man-hour Norms Productivity Contracting Strategy are from the outset linked to the overall business objectives, and as such, can be designed to measure productivity and output from the contractors. Benefits can accrue from: • Reduction of maintenance cost • Visibility of actual work time • Separation of cost of work and overheads and profit • Standardised Norm sets • Benchmarking • Simplified tendering process • Standard Contract forms • Ability to drive productivity improvements • Knowledge Retention.
1.2 Overview of Disciplines Used and Services EC Harris’s unique Man-hour Norms Productivity Contracting Strategy provides the client with full visibility of the cost of work performed. This linked with our Schedules of Norms which cover all major disciplines of work activities allows the client to contract for maintenance services and benchmark across locations. Discipline Norms include:
• Scaffolding. • Steelwork • Static Equipment • Rotating Equipment • HVAC • Mechanical Pipework • Electrical & Instrumentation • Insulation • Painting • Cleaning • Tankage • Civil & Building • Fireproofing • Safety & Loss Prevention
9
2 Factors The norms contained in this document are ‘Pure’ Norms, that is they only contain the time to complete the task (wrench time). To utilise these Norms for maintenance or projects across various locations across the globe the following factor table should be used.
Region Maintenance Projects
Middle East 1.3 1.2 Far East 1.8 1.7 USA 1.5 1.4 Europe 1.2 1.1
The factors should be applied to the norms as multipliers.
3 General Rules and Definitions The following units of measurement and abbreviations have been used within this document: a. Metre m b. Foot ft c. Inch in d. Millimetre mm e. Kilogram kg f. Pound lb g. Tonne t h. Number Nr i. Nominal bore n.b. j. Diameter dia k. Reference ref l. Square metres m2
m.. Square feet ft2 n. Cubic metres m3
o. Cubic Metres ft3 The Method of Measurement and the following Appendices allow for the measurement and valuation of the norms on either a metric or imperial basis. Each Site/Country is free to select the method of measurement most suitable for them. This document has been drafted in such a way as to make reference to both methods of measurement. This document must remain as drafted and each Site/Country shall select the appropriate method of measurement. Unless specifically required by the Company temporary works shall not be measured but the provision of the same is deemed to be included within the Global Norms for the specific item to which it applies.
10
3.1 Design Information Where the Contractor is required to carry out any engineering design and drawing work, this shall be stated in the Purchase Order. The extent of the work shall be defined. In the absence of specification information, descriptions or drawings and other information relative to the Task, the Contractor shall execute the work in accordance with the Specifications and Company Standards. General arrangement and other pipework drawings will not always indicate make-up pieces and/or loose flanges. The Contractor must assume that pipes fabricated to the actual calculated dimensions will not necessarily fit exactly. The Contractor is responsible for checking the sufficiency of closure pipes, etc., where shown and for determining the position and number of any additional loose flanges and must include in the Selling Rate all necessary site measurement and sketching including temporary erection to obtain final dimensions for closure pipes.
4 Introduction to the Contracting Methodology The norms have been set at a baseline of an average site and location and at a level that is challenging. The Norms assume standard working conditions at a normal working height. The purpose of this is to allow the estimator or contractor to apply a number of factors to the base norms to adjust them for the prevailing conditions. There are 3 groups of factors that can be applied, namely • A Contract factor • A Condition factor • A Material factor Taking each of these factors in turn
4.1 Contract Factors The Global Norm shall be adjusted by a figure of one plus the aggregate of the Contract Factors as defined, and in the manner described, below. The Global Norm shall be adjusted by the application of the Contract Factor which can have several components, namely:- - Efficiency Factor - Site Factor - Location Factor
11
4.2 Efficiency Factor This factor shall be expressed as a percentage and represents the saving in time that the Contractor believes he can achieve or the additional time that the Contractor requires to complete a Task compared to the Global Norm. For instance if the Contractor believes he can complete a Task 5% faster than the Global Norm then the Efficiency Factor will be expressed as -5%. If the Contractor believes he will require 5% more time than the Global Norm then the factor shall be expressed as +5%.
4.3 Site Factor This factor shall represent the time saving or additional time required by the Contractor compared to the Global Norms set out in the following Appendices to execute a Task, taking into account the particular features of the Site and its location. The particular features that are deemed relevant are a matter for the Contractor’s judgement and may include the overall area of the Site, access around the Site, the average distance from the Contractor’s compound to the work area, local average weather conditions, local site rules, etc. The Site Factor shall have been tendered by the Contractor and shall, as for Efficiency Factor, be expressed as a percentage of the Global Norm.
4.4 Location Factors This factor shall be used to adjust the norms for the geographic region were the norms are being applied. This factor would typically take in to account the prevailing working conditions in that region.
4.5 Condition Factors Condition Factors are the factors identified below which represent the amount of adjustment to be applied to the Contract Norms to take account of the ease, complexity or difficulty in executing work in the specific conditions. The resultant Norm shall be known as the “Factored Norm”.
The Condition Factors are fixed and shall not be subject to any adjustment whatsoever during the Contract Period. Description FactorHeight > 6m up to 12m (>20 ft up to 40 ft) 1.03 Height > 12m up to 18m (>40 ft up to 60ft) 1.05 Height > 18m up to 24m (>60 ft up to 80 ft) 1.08 Height > 24m (>80 ft) 1.10 Working in a confined space 1.10 Wearing restrictive PPE or using breathing apparatus 1.15
12
4.6 Material Factors The Material Factors are factors determined by the Company and are applied to the Global Piping Norms for working in different materials other than Carbon Steel, from which the base norms have been generated. The Global Norms shall be multiplied by a the Contract Factor and the Material Factor in accordance with the Contract, the resulting Norms will be called the Contract Norms. The Material Factors are fixed and shall not be subject to any adjustment whatsoever during the Contract Period.
MaterialMaterial Factor
Stainless Steel 1.25 Low Temp Carbon Steel 1.15 Inconel 1.25 Incolloy 1.25 Monel 1.25 Aluminium 1.50 Chrome 1.25 Molybdenum Steels 1.25 Duplex 1.66 Cupro Nickel 1.50
4.7 Application of Factors The Global Norms are set out in the following Appendices. Each Activity in the Global Norms will be fully inclusive of all the work as described in the Activity, Specification, the relevant preambles and elsewhere in the Contract required to complete that Activity. The Contractor shall be deemed to have allowed within the Selling Rate, Contract Factor, Condition Factors, Materials Factors and all other rates and prices within the Contract for all costs and expenses which may be incurred for the completion of the Works in accordance with the Contract and any risks, responsibilities, liabilities and obligations set forth or implied in the Contract. The Global Norms shall be adjusted by a figure of one plus the Contract Factor and one plus the Material Factor in accordance with the Contract, the resulting Norms will be called the Contract Norms. The Global Norms apply to carbon steel pipework and shall be adjusted by the Material Factors in accordance with the Contract when used with other materials.
13
Where the Company considers that specific working conditions apply, the Contract Norms will be adjusted by a figure of one plus the aggregate of the Condition Factors in accordance with the Contract. The Schedule of Global Norms will not be adjusted for any other conditions other than those specified in the Contract.
4.8 Constituents of the Selling Rate The Selling Rates shall be deemed to be based upon those rates current and for the duration of the Contract Period and shall include wages, all other labour charges or emoluments, cost of materials and consumables but excludes Corporate Overheads, Profit and Site Establishment costs. In particular the Selling Rates shall include for, but not be limited to, costs in connection with the following:- � All costs in connection with employment of labour and maintaining an
adequate labour force onsite including costs arising from wage rates and labour union agreements, inclement weather, protective clothing and equipment, transport to Site of labour from any source, fares, lodging and subsistence, holidays, travelling time, training, proficiency payments, incentive bonus schemes, inspections, severance pay, recruitment, statutory insurance and any other amounts payable in accordance with National or Local Government enactments.
� All costs in connection with any overtime necessary to work the
normal working week as stated in the Contract. � Insurances. � All costs associated in maintaining full compliance with statutory and
Site health, safety and environmental regulations and requirements, including attendance by all Contractor’s personnel at Site inductions as required.
� Housekeeping, keeping of work areas in a clean and tidy condition in
accordance with Company requirements. � Providing all necessary training, whether on the job or off site. � Toolbox talks. � All allowances for waste. � Checking the accuracy of the Company’s material quantities listed on
drawings or other documents, or where not listed calculating such quantities.
14
� Taking delivery of materials at the Company’s, the Contractor’s or his Sub-Contractor’s workshops, including unloading, handling and storage.
� Transporting all labour, materials, fabricated items, plant and
equipment to or from the Company’s, the Contractor’s or his Sub-Contractor’s workshops or to the place of installation or other such place necessary for the execution of the work, including loading and unloading, handling and storage.
� Sorting and checking materials in any location. � Removal from Site and disposal of empty containers, packaging
material or waste, including any necessary cleaning. � All necessary marking (e.g. labelling, tagging, painting, etc. of pipes,
plant, equipment, hangers, supports, brackets and the like), for identification purposes. This applies to all items whether supplied by the Company or the Contractor. In particular special attention should be given to the marking of all fabricated pipes, which are subsequently to be galvanised, rubber lined heated, etc., to ensure they can be correctly identified after the completion of such operations.
� Provision, tools, all consumable items including but not limited to
water, fuel, gases, welding electrodes and any other equipment necessary for the execution of the Task.
� Supply of all necessary testing equipment, including spades, slip
plates, plugs, blanks, temporary spools, hoses, pumps, gauges and the like.
� The carrying out of welder's tests including the submission of
specimen welds for examination by the Company. � Supply, erection and dismantling of welding tents or similar. � Working within and/or adjacent to operational plants and all
consequential restrictions in the method of working. � Compliance with permit to work and clearance note requirements,
including preparing necessary associated request documentation. � Working around and liaising with the Company’s own labour and
personnel. � Working around, liaising and co-operating with the Company’s other
contractors.
15
� Working in any location on the Site or in the Company’s, Contractor’s or subcontractor’s facilities onsite or offsite.
� Costs arising from compliance with all specifications referred to in
this Contract, including costs in connection with inspection. � Compliance with all statutory obligations, which are applicable to the
Task. � Provision, erecting, dismantling and hire of scaffold, ladders, trestles,
platforms, planks and any other necessary means of access up to 2 metres high for use by the Contractor.
� Working off scaffolding, cradles, ladders and any other means of
access compliant with site health, safety and environmental regulations.
� Provision of temporary bracing and materials, including temporary
bracing during transportation, and for other temporary works during execution of the works.
� All necessary protection of the work and adjacent areas and making
good damage caused by the Contractor. � All necessary allowances for loss of productivity or non-productive
time due to inclement weather. � Setting out the works from datum provided by the Company and for
checking dimensions and levels shown on drawings. No claim arising out of the Contractor’s failure to do so or out of any misunderstanding on his part in this connection will be allowed.
� All necessary attendance to carry out radiography tests where
specified and waiting time associated therewith. � Making fabrication drawings from isometrics, general arrangement
drawings and the like. � All necessary measuring and sketching for the fabrication and
erection of pipework and pipe supports, etc. � Processing the initial and each and every subsequent re-issue of
Company's drawings through the Contractor's offices, workshops etc. � Providing the Company with drawings marked to show the location of
loose flanges and site butt welds. � Marking up drawings to indicate the ‘as built’ condition following
completion of Tasks and supply of 1 no copies of ‘as built’ drawings to the Company.
16
� Compliance with all Quality Assurance obligations as specified in this
Contract including, but not limited to, the provision of all documentation and obtaining approval of the same.
� Compliance in all other respects with all obligations and liabilities
under the Contract and at law not specifically referred to above and not included within the description of the Activities in the Schedules of Norms enclosed in the following sections.
17
D.1 Scaffolding Norms
D.2.1. Coventional Scaffolding Conventional Scaffolding
Scaffold Category Description Unit Erect <6M
Dismantle <6M
Combined Norm Unit Erect
<20ftDismantle
<20ftCombined
NormConventional General Independent up to 10m (33 ft) in length m3 0.128 0.064 0.192 ft3 0.0036 0.0018 0.0054
Conventional General Independent >10m up to 30m (>33 ft up to 100 ft) long m3 0.097 0.048 0.145 ft3 0.0027 0.0014 0.0041
Conventional General Independent > 30m up to 50m (>100 ft up to 165 ft) long m3 0.092 0.046 0.138 ft3 0.0026 0.0013 0.0039
Conventional General Independent > 50 m (>165 ft) long m3 0.090 0.045 0.135 ft3 0.0025 0.0013 0.0038
Conventional General Independent Tower m3 0.147 0.074 0.221 ft3 0.0042 0.0021 0.0063
Conventional General Mobile tower m3 0.147 0.074 0.221 ft3 0.0042 0.0021 0.0063
Conventional General Birdcage up to 50 m3 (1765 ft3) m3 0.083 0.042 0.125 ft3 0.0024 0.0012 0.0035
Conventional General Birdcage > 50 m3 up to 200 m3 (>1765 ft3 up to 7062 ft3) m3 0.067 0.034 0.101 ft3 0.0019 0.0010 0.0029
Conventional General Birdcage > 200 m3 up to 500 m3 (>7062 ft3 up to 17657 ft3) m3 0.054 0.027 0.081 ft3 0.0015 0.0008 0.0023
Conventional General Birdcage > 500m3 (>17657 ft3) m3 0.049 0.025 0.074 ft3 0.0014 0.0007 0.0021
Conventional Special Platform m2 0.216 0.108 0.324 ft2 0.0201 0.0100 0.0301
Conventional Special Suspended m2 0.282 0.141 0.423 ft2 0.0262 0.0131 0.0393
Conventional Special Cantilever m2 0.216 0.108 0.324 ft2 0.0201 0.0100 0.0301
Conventional Special Bridging Span m2 0.245 0.123 0.368 ft2 0.0228 0.0114 0.0342
Conventional Special Ramp m2 0.262 0.131 0.393 ft2 0.0243 0.0122 0.0365
Conventional Misc Decking - inc toe boards and double guard rails m2 0.084 0.042 0.126 ft2 0.0078 0.0039 0.0117
Conventional Barriers Single Rail m 0.115 0.057 0.172 ft 0.0350 0.0175 0.0524
Conventional Barriers Doublerail Freestanding m 0.143 0.072 0.215 ft 0.0437 0.0219 0.0655
Conventional Barriers Triple Rail FreeStanding m 0.171 0.086 0.257 ft 0.0522 0.0261 0.0784
Conventional Miscellaneous Sheds - enclosed scaffold structre m3 0.177 0.088 0.265 ft3 0.0050 0.0025 0.0075
Conventional Miscellaneous Staircase m 0.328 0.164 0.492 ft 0.1000 0.0500 0.1500
Conventional Miscellaneous Flameproof tarpaulin m2 0.085 0.042 0.127 ft2 0.0079 0.0039 0.0118
Conventional Miscellaneous Flameproof corrugated sheet m2 0.122 0.061 0.183 ft2 0.0113 0.0057 0.0170
Conventional Miscellaneous Flameproof plastic sheet m2 0.050 0.025 0.075 ft2 0.0046 0.0023 0.0070
Conventional Miscellaneous Additional ladders m 0.063 0.032 0.095 ft 0.0193 0.0097 0.0290
Conventional Miscellaneous Pulley and rope Nr 0.245 0.123 0.368 Nr 0.245 0.123 0.368
Metric Imperial
18
D.2.2. System scaffolding System Scaffolding
Scaffold Category Description UnitErect <6M
Dismantle <6M
Combined Norm Unit
Erect <20ft
Dismantle <20ft
Combined Norm
System General Independent up to 10m (33 ft) in length m3 0.109 0.054 0.163 ft3 0.0031 0.0015 0.0046
System General Independent >10m up to 30m (>33 ft up to 100 ft) long m3 0.082 0.041 0.123 ft3 0.0023 0.0012 0.0035
System General Independent > 30m up to 50m (>100 ft up to 165 ft) long m3 0.078 0.039 0.117 ft3 0.0022 0.0011 0.0033
System General Independent > 50 m (>165 ft) long m3 0.076 0.038 0.115 ft3 0.0022 0.0011 0.0032
System General Independent Tower m3 0.125 0.063 0.188 ft3 0.0035 0.0018 0.0053
System General Mobile tower m3 0.125 0.063 0.188 ft3 0.0035 0.0018 0.0053
System General Birdcage up to 50 m3 (1765 ft3) m3 0.071 0.035 0.106 ft3 0.0020 0.0010 0.0030
System General Birdcage > 50 m3 up to 200 m3 (>1765 ft3 up to 7062 ft3) m3 0.057 0.029 0.086 ft3 0.0016 0.0008 0.0024
System General Birdcage > 200 m3 up to 500 m3 (>7062 ft3 up to 17657 ft3) m3 0.046 0.023 0.069 ft3 0.0013 0.0007 0.0019
System General Birdcage > 500m3 (>17657 ft3) m3 0.042 0.021 0.063 ft3 0.0012 0.0006 0.0018
System Special Platform m2 0.184 0.092 0.275 ft2 0.0171 0.0085 0.0256
System Special Suspended m2 0.240 0.120 0.360 ft2 0.0223 0.0111 0.0334
System Special Cantilever m2 0.184 0.092 0.275 ft2 0.0171 0.0085 0.0256
System Special Bridging Span m2 0.209 0.104 0.313 ft2 0.0194 0.0097 0.0291
System Special Ramp m2 0.223 0.111 0.334 ft2 0.0207 0.0103 0.0310
System Misc Decking - inc toe boards and double guard rails m2 0.084 0.042 0.126 ft2 0.0078 0.0039 0.0117
System Barriers Single Rail m 0.097 0.049 0.146 ft 0.0297 0.0149 0.0446
System Barriers Doublerail Freestanding m 0.122 0.061 0.183 ft 0.0371 0.0186 0.0557
System Barriers Triple Rail FreeStanding m 0.146 0.073 0.218 ft 0.0444 0.0222 0.0666
System Miscellaneous Staircase m 0.328 0.164 0.492 ft 0.1000 0.0500 0.1500
System Miscellaneous Flameproof tarpaulin m2 0.085 0.042 0.127 ft2 0.0079 0.0039 0.0118
System Miscellaneous Flameproof corrugated sheet m2 0.122 0.061 0.183 ft2 0.0113 0.0057 0.0170
System Miscellaneous Flameproof plastic sheet m2 0.050 0.025 0.075 ft2 0.0046 0.0023 0.0070
System Miscellaneous Additional ladders m 0.063 0.032 0.095 ft 0.0193 0.0097 0.0290
System Miscellaneous Pulley and rope Nr 0.245 0.123 0.368 Nr 0.245 0.123 0.368
ImperialMetric
19
E.1 Steel Work Norms
E.2.1 Fabricate & Install Primary and Secondary Ste el Items All Carbon Steel Grades
UoM N.exc. 200 Kg/m
Exc. 200 N.exc 300
Kg/m
Exc. 300 N.exc 400
Kg/m
Exc. 400 N.exc 500
Kg/m
Exc. 500 N.exc 1000
Kg/m
Exc. 1000 Kg/m
Compound Members Kg 0.10 0.05 0.04 0.03 0.02 0.01
All Carbon Steel Grades & Cast steel
UoM N.exc. 50 kg/m
Exc. 50 N.exc 100
Kg/m
Exc. 100 N.exc 300
Kg/m
Exc. 300 N.exc 500
Kg/m
Exc. 500 Kg/m
Tubulars Kg 0.11 0.09 0.07 0.05 0.04
All Carbon Steel Grades & Cast steel
UoM Plates in Nodes
Plates in Boxes
Cast Steel Items
Nodes and Boxes Kg 0.04 0.04 0.07
20
All Carbon Steel Grades & Cast steel
UoM N.exc. 50 kg/m
Exc. 50 N.exc 100
Kg/m
Exc. 100 N.exc 300
Kg/m
Exc. 300 N.exc 500
Kg/m
Exc. 500 Kg/m
Profiles Kg 0.08 0.06 0.04 0.03 0.02
All Carbon Steel Grades & Cast steel
UoM Plate Cast Steel Items
Plate in Panels Kg 0.10Plate in Misc.Items Kg 0.11Padeyes Kg 0.15 0.05Gussets & Stiffeners Kg 0.20Stabbing Cones and Rolled Cans Kg 0.09
E.2.2 Manual & semi-automatic Welding of Primary & Secondary Steel Items All Carbon Steel Grades & Cast steel
UoM n.e. 6mm Over 6mm n.e. 10mm
Over 10mm n.e. 15mm
Over 15mm n.e. 20mm
Over 20mm n.e. 25mm
Over 25mm n.e. 30mm
Over 30mm n.e. 35mm
Over 35mm n.e. 40mm
Over 40mm n.e. 45mm
Over 45mm n.e. 50mm
Over 50mm n.e. 60mm
Over 60mm n.e. 75mm
Over 75mm n.e. 90mm
Single Fillet Welds m 1.04 1.80 4.41 5.31 8.15 11.70 15.35Single sided Full Pen. Butt Welds m 1.62 3.47 5.90 9.77 13.37 17.15 22.50 28.71 34.25 37.08 46.17 66.33 83.30Double sided Full Pen. Butt Welds m 1.58 2.97 4.55 8.15 11.12 12.92 16.07 18.50 20.75 25.43 29.25 41.00 51.35Tubular Branch Weld m 3.51 6.21 13.46 15.48 23.13 31.82 39.38 48.38 55.13 68.81 92.39 104.54 117.59Partial Pen. Butt Welds m 2.07 4.28 6.57 11.39 16.88 21.20 28.35 36.77 40.01
21
E.2.3 Automatic Welding of Primary & Secondary Stee l Items All Carbon Steel Grades & Cast steel
UoM n.e. 6mm Over 6mm n.e. 10mm
Over 10mm n.e. 15mm
Over 15mm n.e. 20mm
Over 20mm n.e. 25mm
Over 25mm n.e. 30mm
Over 30mm n.e. 35mm
Over 35mm n.e. 40mm
Over 40mm n.e. 45mm
Over 45mm n.e. 50mm
Over 50mm n.e. 60mm
Over 60mm n.e. 75mm
Over 75mm n.e. 90mm
Single Fillet Welds m 0.25 0.40 1.20 2.45 4.05 6.55Single sided Full Pen. Butt Welds m 0.75 1.30 2.45 3.90 5.40 5.75 7.60 9.75 11.75 12.70 15.95 23.35 29.50Double sided Full Pen. Butt Welds m 0.70 1.10 1.90 3.30 3.85 4.45 5.40 6.60 7.35 9.25 10.55 15.15 19.10Partial Pen. Butt Welds m 0.65 0.75 1.50 2.35 3.25 5.30 6.95 8.90 10.70
22
E.2.4 Bolting of Primary & Secondary Steel Items All Carbon Steel Grades & Cast steelDrilling of Holes
UoM n.e. 12mm dia
Over 12mm n.e. 25mm
dia
Over 25mm dia
In Plate n.e. 20mm thick Nr 0.09 0.13 0.16In Plate over 20mm n.e. 40mm thick Nr 0.11 0.16 0.18In Plate over 40mm thick Nr 0.15 0.21 0.24
All Carbon Steel Grades & Cast steelThreading of Holes
UoM n.e. 12mm dia
Over 12mm n.e. 25mm
dia
Over 25mm dia
In Plate n.e. 20mm thick Nr 0.13 0.14 0.16In Plate over 20mm n.e. 40mm thick Nr 0.16 0.17 0.18In Plate over 40mm thick Nr 0.18 0.25 0.30
All Carbon Steel Grades & Cast steelBolting
UoM n.e. 12mm dia
Over 12mm n.e. 25mm
dia
Over 25mm dia
In all Plate thicknesses Nr 0.08 0.10 0.12
23
E.2.5 Fabricate and Install Outfitting Steelwork St eel All Carbon Steel Grades & Cast steel
UoM Fab. & Install
Stairways and Ladders Kg 0.28Walkways ,Platforms and Landings Kg 0.13Plate in Flooring for W/ways,P/forms,Landing,Stair Treads
Kg 0.15
Serated Bar Grating in Flooring for W/ways,P/forms,Landing,Stair Tread
Kg 0.06
Low Density Punched Plate in Flooring for W/ways,P/forms,Landing,Stair Tread
Kg 0.06
Handrails,Guardrails and Crash Barriers Kg 0.27Major Piperacks Kg 0.17Stair Towers Kg 0.12Supporting framework for platform signs Kg 0.22Galvanizing of steelwork Kg 0.04
24
FA.1 Static Equipment Norms
FA.2.1 Isolate & De-isolate Pipework Isolate Pipework (Spade)
n.b. - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 6 00 750 900 1100 1200
n.b. - inch 5/8" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" 44" 48"
Isolate 150# No. 0.42 0.42 0.42 0.46 0.50 0.51 0.52 0.83 0.98 1.11 1.97 2.12 2.32 3.04 3.49 4.33 4.91 6.78 8.87 10.97 13.29
Isolate 300# No. 0.42 0.46 0.54 0.62 0.92 1.00 1.05 1.17 1.68 1.93 2.90 3.28 4.24 4.74 5.70 6.19 6.72 8.87 11.02
Isolate 600# No. 0.42 0.46 0.54 0.62 0.92 1.02 1.11 1.28 2.03 2.40 3.60 4.79 5.29 5.78 6.28 7.48 8.23 9.68 10.56
Isolate 900# No. 0.42 0.46 0.54 0.62 1.09 1.19 1.28 1.46 2.43 2.91 4.12 5.31 5.98 6.64 7.32 7.99 9.33
Isolate 1500# No. 0.42 0.46 0.54 0.62 1.09 1.22 1.34 1.57 2.78 3.38 4.00 5.19 6.04 6.89 7.73 8.57 9.80
Pipe Diameter
Description
De-isolate Pipework (Spade)
n.b. - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 6 00 750 900 1100 1200
n.b. - inch 5/8" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" 44" 48"
De-isolate 150# No. 0.41 0.41 0.41 0.44 0.48 0.50 0.50 0.81 0.96 1.09 1.94 2.09 2.29 3.00 3.45 4.29 4.86 6.73 8.81 10.91 13.22
De-isolate 300# No. 0.41 0.45 0.53 0.60 0.90 0.99 1.03 1.15 1.66 1.91 2.87 3.25 4.21 4.70 5.66 6.15 6.67 8.82 10.96
De-isolate 600# No. 0.41 0.45 0.53 0.60 0.90 1.01 1.09 1.26 2.01 2.38 3.57 4.76 5.26 5.74 6.24 7.44 8.18 9.63 10.50
De-isolate 900# No. 0.41 0.45 0.53 0.60 1.07 1.18 1.26 1.44 2.41 2.89 4.09 5.28 5.95 6.60 7.28 7.95 9.28
De-isolate 1500# No. 0.41 0.45 0.53 0.60 1.07 1.21 1.32 1.55 2.76 3.36 3.97 5.16 6.01 6.85 7.69 8.53 9.75
Pipe Diameter
Description
25
Isolate or De-isolate Pipework (Spectacle Blind))
n.b. - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 6 00 750 900 1100 1200
n.b. - inch 5/8" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" 44" 48"
Isolate 150# No. 0.33 0.33 0.33 0.37 0.38 0.38 0.39 0.70 0.98 0.93 1.76 1.89 2.07 2.76 3.19 4.01 4.54 6.37 8.41 10.47 12.74
Isolate 300# No. 0.33 0.37 0.45 0.50 0.80 0.87 0.92 1.04 1.68 1.75 2.69 3.05 3.99 4.46 5.40 5.87 6.35 8.46 10.56
Isolate 600# No. 0.33 0.37 0.45 0.50 0.80 0.89 0.98 1.15 2.03 2.22 3.39 4.56 5.04 5.50 5.98 7.16 7.86 9.27 10.10
Isolate 900# No. 0.33 0.37 0.45 0.50 0.97 1.06 1.15 1.33 2.43 2.73 3.91 5.08 5.73 6.36 7.02 7.67 8.96
Isolate 1500# No. 0.33 0.37 0.45 0.50 0.97 1.09 1.21 1.44 2.78 3.20 3.79 4.96 5.79 6.61 7.43 8.25 9.43
Pipe Diameter
Description
26
FA.2.2 Install / remove manway covers
Install / Remove Manway Covers
Unit 150# 300# 600# 900# 1500#
n.e. 200mm n.e. 8" No. 0.55 0.74 0.81 0.90 0.97
over 200mm n.e. 400mm over 8" n.e. 16" No. 1.24 1.76 2.15 2.44 2.37
over 400mm n.e. 600mm over 16" n.e. 24" No. 1.88 2.82 3.41 3.89 4.02
over 600mm n.e. 800mm over 24" n.e. 32" No. 2.98 3.99 4.83 5.44 5.70
Install / Remove Manway Covers, with Davit.
Unit 150# 300# 600# 900# 1500#
n.e. 200mm n.e. 8" No. 0.35 0.54 0.61 0.70 0.77
over 200mm n.e. 400mm over 8" n.e. 16" No. 0.94 1.36 1.85 2.14 2.07
over 400mm n.e. 600mm over 16" n.e. 24" No. 1.48 2.42 3.01 3.49 3.62
over 600mm n.e. 800mm over 24" n.e. 32" No. 2.48 3.49 4.33 4.94 5.20
Pressure Rating
Pressure Rating
Manway size
Manway size
27
FA.2.3 Shell Repairs – incl. Welding
Wall Thickness Unit n.e 0.04m2 over 0.04m2
n.e. 0.09m2 over 0.09m2
n.e.0.16m2 over 0.16m2
n.e. 0.25m2 over 0.25m2 n.e.
0.36m2 over 0.36m2
n.e.0.49m2
Wall Thickness n.e. 8mm No. 6.19 7.24 9.33 11.42 13.52 15.61
Wall Thickness over 8mm n.e.12mm No. 6.73 7.91 10.27 12.64 15.00 17.36
Wall Thickness over 12mm n.e. 15mm No. 7.50 8.87 11.62 14.37 17.12 19.87
Wall Thickness over 15mm n.e. 20mm No. 7.95 9.43 12.40 15.38 18.35 21.32
Wall Thickness over 20mm n.e. 25mm No. 8.61 10.26 13.56 16.87 20.17 23.47
Plate Dimensions
Wall Thickness Unit n.e 0.5ft2over 0.5 ft2 n.e.1
ft2over 1ft2
n.e.2ft2over 2ft2
n.e.3ft2over 3ft2
n.e.4ft2over 4ft2
n.e.5ft2
Wall Thickness n.e.0.32" No. 6.88 7.46 10.08 12.56 13.92 14.67
Wall Thickness over 0.32" n.e 0.47" No. 7.47 8.15 11.09 13.90 15.45 16.32
Wall Thickness over 0.47" n.e. 0.59" No. 8.33 9.14 12.55 15.81 17.63 18.68
Wall Thickness over 0.59" n.e. 0.79" No. 8.82 9.71 13.39 16.92 18.90 20.04
Wall Thickness over 0.79" n.e. 1.00" No. 9.56 13.34 14.64 18.56 20.78 22.06
Plate Dimensions
28
FA.2.4 Welding
Wall Thickness Unit Butt Weld Fillet Weld Overlay
Build up weld overlay in single runs m 0.31
n.e. 8mm m 3.61 1.30
over 8mm n.e. 12mm m 3.99 1.90
over 12mm n.e. 15mm m 4.46
over 15mm n.e. 20mm m 5.25
over 20mm n.e. 25mm m 6.51
Wall Thickness Unit Butt Weld Fillet Weld Overlay
Build up weld overlay in single runs ft 0.09
n.e. 0.32" ft 1.10 0.40
over 0.32" n.e. 0.47" ft 1.22 0.58
over 0.47" n.e. 0.59" ft 1.36
over 0.59" n.e. 0.79" ft 1.60
over 0.79" n.e. 1.00" ft 1.98
29
FA.2.5 Furnace & Boilers
n.e.250mmover 250mm n.e.
500mmover 500mm n.e.
750mmover 750mm n.e.
1000mm
n.e.10" over 10" n.e. 20" over 20" n.e. 30" over 30" n .e. 40"
Remove Burner Lance No. 0.24 0.34 0.43 0.66
Re-fit Burner Lance No. 0.31 0.43 0.54 0.79
Burner Lance Length
UnitDescription
30
FA.2.6 Heat Exchangers
Heat Exchangers
Description Unit 0-500 500-1000 1000-1500 1500-2000 2000-2500 2500-30 00 3000-3500 3500-4000
Remove end cover No. 0.50 1.50 3.00 4.20 5.20 6.80 8.30 10.20
Remove Floating Head Cover & Clamp Rings No. 0.50 1.60 2.30 2.90 4.20 6.00 8.40 12.00
Remove inlet/outlet chamber cover No. 0.30 0.90 1.80 2.60 3.20 4.00 5.30 6.60
Remove inlet/outlet chamber No. 0.50 1.50 3.00 4.20 5.40 6.80 8.30 10.20
Pull bundle No. 1.00 4.00 5.80 7.50 9.10 10.70 12.50 14.00
Pull bundle - with Puller No. 0.50 2.00 4.00 5.10 6.00 7.00 7.90 9.20
Re-fit Bundle No. 1.00 4.00 6.70 7.50 10.90 12.80 15.00 16.10
Re-fit Bundle - with Puller No. 0.50 2.00 2.50 3.40 4.10 5.80 8.60 9.40
Pressure test shell No. 0.50 2.00 2.60 3.30 4.30 5.70 8.20 9.60
pressure test shell - with test ring No. 3.50 3.80 5.60 6.65 8.40 11.40 17.40 20.10
pressure test bundle No. 2.00 4.00 5.30 6.00 6.80 7.60 8.60 9.40
Re-fit end cover No. 0.50 1.50 3.00 4.20 6.00 7.20 9.00 10.20
Re-fit Floating Head Cover & Clamp Rings No. 0.50 1.60 2.60 3.70 5.10 7.00 9.20 12.00
Re-fit inlet/outlet chamber No. 0.50 1.50 3.00 4.20 6.00 7.20 9.00 10.20
Re-fit inlet/outlet chamber cover No. 0.30 0.90 1.80 2.60 3.80 4.60 5.80 6.60
Outer Diameter of Sealing Face
31
Description Unit 0 - 1' 6" 1'6" - 3' 3' - 4'6" 4'6" - 6' 6' - 7'6" 7' 6" - 9' 9' - 10'6" 10'6" - 12'
Remove end cover No. 0.45 1.35 2.70 4.20 4.68 6.80 7.47 9.18
Remove Floating Head Cover & Clamp Rings No. 0.45 1.44 2.07 2.90 3.78 6.00 7.56 10.80
Remove inlet/outlet chamber cover No. 0.27 0.81 1.62 2.60 2.88 4.00 4.77 5.94
Remove inlet/outlet chamber No. 0.45 1.35 2.70 4.20 4.86 6.80 7.47 9.18
Pull bundle No. 0.90 3.60 5.22 7.50 8.19 10.70 11.25 12.60
Pull bundle - with Puller No. 0.45 1.80 3.60 5.10 5.40 7.00 7.11 8.28
Re-fit Bundle No. 0.90 3.60 6.03 7.50 9.81 12.80 13.50 14.49
Re-fit Bundle - with Puller No. 0.45 1.80 2.25 3.40 3.69 5.80 7.74 8.46
Pressure test shell No. 0.45 1.80 2.34 3.30 3.87 5.70 7.38 8.64
pressure test shell - with test ring No. 3.15 3.42 5.04 6.65 7.56 11.40 15.66 18.09
pressure test bundle No. 1.80 3.60 4.77 6.00 6.12 7.60 7.74 8.46
Re-fit end cover No. 0.45 1.35 2.70 4.20 5.40 7.20 8.10 9.18
Re-fit Floating Head Cover & Clamp Rings No. 0.45 1.44 2.34 3.70 4.59 7.00 8.28 10.80
Re-fit inlet/outlet chamber No. 0.45 1.35 2.70 4.20 5.40 7.20 8.10 9.18
Re-fit inlet/outlet chamber cover No. 0.27 0.81 1.62 2.60 3.42 4.60 5.22 5.94
Outer Diameter of Sealing Face
32
FA.2.7 Heat Exchanger / Air Cooler – Unbolting & Bo lting UnboltingBolt Diameter Bolt Diameter 0-12 13-24 25-36 37-48 49-60 61-72 73-84 85-96 97-108 109-120 121-140 141-160 161-180 181-200
Up to and including 15mm Up to and including 1/2 inch 0.228 0.684 1.14 1.596 2.052 2.508 2.964 3.42 3.876 4.332 4.94 5.7 6.46 7.22
Greater than 15mm up to and including 20mm Greater than 1/2 inch up to and including 3/4 inch 0.264 0.792 1.32 1.848 2.376 2.904 3.432 3.96 4.488 5.016 5.72 6.6 7.48 8.36
Greater than 20mm up to and including 25mm Greater than 3/4 inch up to and including 1 inch 0.42 1.26 2.1 2.94 3.78 4.62 5.46 6.3 7.14 7.98 9.1 10.5 11.9 13.3
Greater than 25mm up to and including 40mm Greater than 1 inch up to and including 1 1/2 inch 1.02 3.06 5.1 7.14 9.18 11.22 13.26 15.3 17.34 19.38 22.1 25.5 28.9 32.3
Greater than 40mm up to and including 50mm Greater than 1 1/2 inch up to and including 2 inch 1.2 3.6 6 8.4 10.8 13.2 15.6 18 20.4 22.8 26 30 34 38
BoltingBolt Diameter Bolt Diameter 0-12 13-24 25-36 37-48 49-60 61-72 73-84 85-96 97-108 109-120 121-140 141-160 161-180 181-200
Up to and including 15mm Up to and including 1/2 inch 0.228 0.684 1.14 1.596 2.052 2.508 2.964 3.42 3.876 4.332 4.94 5.7 6.46 7.22
Greater than 15mm up to and including 20mm Greater than 1/2 inch up to and including 3/4 inch 0.264 0.792 1.32 1.848 2.376 2.904 3.432 3.96 4.488 5.016 5.72 6.6 7.48 8.36
Greater than 20mm up to and including 25mm Greater than 3/4 inch up to and including 1 inch 0.42 1.26 2.1 2.94 3.78 4.62 5.46 6.3 7.14 7.98 9.1 10.5 11.9 13.3
Greater than 25mm up to and including 40mm Greater than 1 inch up to and including 1 1/2 inch 1.224 3.672 6.12 8.568 11.016 13.464 15.912 18.36 20.808 23.256 26.52 30.6 34.68 38.76
Greater than 40mm up to and including 50mm Greater than 1 1/2 inch up to and including 2 inch 1.44 4.32 7.2 10.08 12.96 15.84 18.72 21.6 24.48 27.36 31.2 36 40.8 45.6
Number of Bolts
Number of Bolts
33
FA.2.8 Air Coolers
Remove inlet chamber
n.e. 2.0mover 2.0m n.e. 3.0m
over 3.0m n.e. 4.0m
over 4.0m n.e. 5.0m
over 5.0m
n.e. 80inover 80in n.e. 120in
over 120in n.e. 160in
over 160in n.e. 200in
over 200in
n.e. 0.5m n.e. 20in No. 1.5 2 2.5 3.1 4.2
over 0.5m n.e.1m over 20in n.e.40in No. 2.5 3.8 4.45 5.1 6.15
over 1m n.e.1.5m over 40in n.e.60in No. 3.2 4.85 5.8 6.75 7.8
over 1.5m n.e.2m over 60in n.e.80in No. 3.8 5.8 7.1 8.2 9.5
Refit inlet chamber
n.e. 2.0mover 2.0m n.e. 3.0m
over 3.0m n.e. 4.0m
over 4.0m n.e. 5.0m
over 5.0m
n.e. 80inover 80in n.e. 120in
over 120in n.e. 160in
over 160in n.e. 200in
over 200in
n.e. 0.5m n.e. 20in No. 1.815 2.18 2.725 3.38 4.578
over 0.5m n.e.1m over 20in n.e.40in No. 3.025 4.142 4.8505 5.559 6.7035
over 1m n.e.1.5m over 40in n.e.60in No. 3.872 5.2865 6.322 7.3575 8.502
over 1.5m n.e.2m over 60in n.e.80in No. 4.598 6.322 7.739 8.938 10.355
Height Height Unit
UnitHeightHeight
Inlet Chamber Width
Inlet Chamber Width
34
FA.2.9 Heat Exchangers / Air Coolers
Description Unit Per Tube
Pressure test tube (individually) No. 0.05
Insert Plug No. 0.80
Description Unit n.e. 0.1Te over 0.1Te n.e. 1Te
over 1Te n.e. 5Te
over 5Te n.e. 10Te
over 10Te n.e. 25Te
over 25Te n.e. 50Te
over 50Te n.e. 100Te
over 100Te n.e. 150Te
Remove/Install Exchanger / Air Cooler No. 10 29 50 81 90 166 258 301
Exchanger Weight (Te)
35
FA.2.10 Columns
Description Unit n.e. 0.50mover 0.50m n.e. 1.00m
over 1.00m n.e. 1.50m
over 1.50m n.e. 2.00m
over 2.00m n.e. 2.50m
over 2.50m n.e. 3.00m
Remove or replace Top Dome No. 0.86 2.86 5.15 7.72 9.44 11.15
Remove or replace demister unit No. 3.00 5.50 7.50 11.50 13.50 22.50
Remove or replace bubble cap tray No. 3.00 8.50 14.00 19.00 24.50 30.00
Remove or replace keyed metaway tray No. 2.00 5.50 9.00 13.00 16.50 20.00
Remove or replace bolted metaway tray No. 2.50 7.00 11.50 16.00 20.50 25.00
External Diameter
Description Unit n.e. 1'6"over 1' 6"
n.e. 3'over 3'
n.e. 4' 6"over 4' 6"
n.e. 6'over 6' n.e.
7' 6"over 7' 6"
n.e. 9'
Remove or replace Top Dome No. 0.77 2.57 4.63 6.95 8.50 10.04
Remove or replace demister unit No. 2.70 4.95 6.75 10.35 12.15 20.25
Remove or replace bubble cap tray No. 2.70 7.65 12.60 17.10 22.05 27.00
Remove or replace keyed metaway tray No. 1.80 4.95 8.10 11.70 14.85 18.00
Remove or replace bolted metaway tray No. 2.25 6.30 10.35 14.40 18.45 22.50
External Diameter
36
Description Unit All Sizes
Remove or replace bubble cap No. 0.10
Remove or replace snap-in valve No. 0.05
n.e. 750mmn.e. 30inch
Remove internal manway No. 2.00
Replace internal manway No. 3.00
UnitDescription
37
FA.2.11 Bursting Discs
n.b. - mm 15 20 25 40 50 65 80 100 150 200 250 300
n.b. - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12"
Remove 150# No. 0.47 0.47 0.50 0.52 0.58 0.61 0.63 0.96 1.30 2.09 3.33 4.01
Remove 300# No. 0.47 0.51 0.61 0.67 0.98 1.05 1.13 1.29 1.97 2.87 4.22 5.11
Remove 600# No. 0.47 0.51 0.61 0.67 0.98 1.08 1.18 1.39 2.29 3.30 4.87 6.54
Remove 900# No. 0.47 0.51 0.61 0.67 1.14 1.24 1.35 1.56 2.67 3.79 5.36 7.03
Remove 1500# No. 0.47 0.51 0.61 0.67 1.14 1.27 1.40 1.67 3.00 4.24 5.25 6.92
Overhaul No. 0.32 0.33 0.34 0.36 0.38 0.40 0.43 0.47 0.52 0.58 0.65 0.72
Re-fit 150# No. 0.56 0.56 0.59 0.62 0.71 0.74 0.77 1.14 1.57 2.61 4.08 4.96
Re-fit 300# No. 0.56 0.61 0.71 0.80 1.14 1.24 1.33 1.51 2.31 3.47 5.06 6.19
Re-fit 600# No. 0.56 0.61 0.71 0.80 1.14 1.27 1.38 1.63 2.67 3.96 5.79 7.78
Re-fit 900# No. 0.56 0.61 0.71 0.80 1.32 1.45 1.57 1.81 3.09 4.50 6.34 8.32
Re-fit 1500# No. 0.56 0.61 0.71 0.80 1.32 1.48 1.63 1.93 3.46 4.99 6.22 8.20
Pipe Diameter
Description
38
FA.2.12 Relief Valves
n.b. - mm 25 x25 25 x 50 40 x 50 50 x 50 40 x 65 50 x 80 4 0 x 80 80 x 80 80 x 100 65x100 100 x 150 150 x 200 150 x 250 200 x 250
n.b. - inches 1"x1" 1"x2" 1 1/2"x2" 2"x2" 1 1/2"x2 1/2" 2"x3" 1 1/2"x3" 3"x3" 3"x4" 2 1/2"x4" 4"x6" 6"x8" 6"x10" 8" x10"
Remove 150# (Inlet) No. 0.49 0.56 0.56 0.58 0.58 0.62 0.60 0.62 0.82 0.82 1.25 2.03 2.89 2.94
Remove 300# (Inlet) No. 0.55 0.62 0.64 0.78 0.66 0.82 0.68 0.87 1.07 1.05 1.41 2.36 3.22 3.33
Remove 600# (Inlet) No. 0.55 0.62 0.64 0.78 0.66 0.82 0.68 0.90 1.10 1.06 1.46 2.53 3.39 3.55
Remove 900# (Inlet) No. 0.55 0.62 0.64 0.86 0.66 0.90 0.68 0.98 1.18 1.14 1.55 2.72 3.58 3.79
Remove 1500# (Inlet) No. 0.47 0.62 0.64 0.86 0.66 0.90 0.68 1.10 1.21 1.16 1.60 2.88 3.74 4.02
Overhaul 150# (Inlet) No. 4.20 5.40 5.40 5.40 6.00 6.00 6.00 6.60 6.60 7.20 7.80 9.00 9.60 10.20
Overhaul 300# (Inlet) No. 4.20 5.40 5.40 5.40 6.00 6.00 6.00 6.60 6.60 7.20 7.80 9.00 9.60 10.20
Overhaul 600# (Inlet) No. 4.20 5.40 5.40 5.40 6.00 6.00 6.00 6.60 6.60 7.20 7.80 9.00 9.60 10.20
Overhaul 900# (Inlet) No. 5.49 7.10 7.10 7.10 7.83 7.83 7.83 8.55 8.55 9.20 9.90 11.14 11.57 11.76
Overhaul 1500# (Inlet) No. 5.49 7.10 7.10 7.10 7.83 7.83 7.83 8.55 8.55 9.20 9.90 11.14 11.57 11.76
Re-fit 150# (Inlet) No. 0.60 0.68 0.68 0.70 0.71 0.76 0.74 0.76 0.98 0.98 1.51 2.55 3.59 3.65
Re-fit 300# (Inlet) No. 0.66 0.94 0.76 0.92 0.79 0.98 0.82 1.04 1.26 1.24 1.69 2.92 3.96 4.08
Re-fit 600# (Inlet) No. 0.66 0.94 0.76 0.92 0.79 0.98 0.82 1.07 1.29 1.25 1.75 3.10 4.14 4.33
Re-fit 900# (Inlet) No. 0.66 0.94 0.76 1.01 0.79 1.07 0.82 1.16 1.38 1.34 1.84 3.31 4.35 4.60
Re-fit 1500# (Inlet) No. 0.66 0.94 0.76 1.01 0.79 1.07 0.82 1.19 1.41 1.35 1.90 3.50 4.54 4.84
Inlet Pipe Diameter
Description
39
FA.2.13 Fire Monitors (Hydrants)
Fire Monitors (Hydrants)
n.b. - mm 80 100
n.b. - inches 3" 4"
Remove No. 0.46 0.65
Refit No. 0.46 0.65
Water Inlet Pipe Diameter
Description
40
FA.2.14 Hoses (Flanged Connection)
Hoses (Flanged connection)
n.b. - mm 15 20 25 40 50 65 80 100 150 200 250 300
n.b. - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12"
Remove 150# No. 0.49 0.49 0.50 0.52 0.57 0.59 0.61 0.92 1.09 1.24 2.08 2.24
Remove 300# No. 0.49 0.53 0.61 0.67 0.97 1.04 1.11 1.24 1.75 2.02 2.96 3.34
Remove 600# No. 0.49 0.53 0.61 0.67 0.97 1.07 1.16 1.35 2.08 2.45 3.62 4.77
Remove 900# No. 0.49 0.53 0.61 0.67 1.13 1.23 1.33 1.52 2.46 2.94 4.11 5.26
pressure test 150# No. 0.63 0.63 0.63 0.67 0.76 0.77 0.82 1.42 1.72 2.01 3.72 4.01
Pressure test 300# No. 0.63 0.72 0.86 0.99 1.59 1.73 1.88 2.12 3.12 3.65 5.58 6.33
Pressure test 600# No. 0.63 0.72 0.86 0.99 1.59 1.78 1.99 2.35 3.82 4.57 6.97 9.35
Pressure test 900# No. 0.63 0.72 0.86 0.99 1.93 2.12 2.35 2.69 4.62 5.60 8.00 10.39
Re-fit 150# No. 0.76 0.76 0.78 0.82 0.91 0.94 0.97 1.37 1.63 1.86 2.89 3.12
Re-fit 300# No. 0.76 0.81 0.91 1.01 1.37 1.48 1.56 1.76 2.40 2.76 3.93 4.41
Re-fit 600# No. 0.76 0.81 0.91 1.01 1.37 1.50 1.62 1.89 2.79 3.28 4.71 6.10
Re-fit 900# No. 0.76 0.81 0.91 1.01 1.56 1.69 1.82 2.07 3.24 3.86 5.28 6.67
Pipe Diameter
Description
41
FA.2.15 Hoses (Screwed Connection) Hoses (Screwed connection)
n.b. - mm 15 20 25 40 50 65 80 100
n.b. - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4"
Remove 150# No. 0.40 0.40 0.42 0.47 0.56 0.65 0.72 0.93
pressure test 150# No. 0.62 0.62 0.65 0.73 0.84 0.93 1.02 1.27
Re-fit 150# No. 0.43 0.43 0.43 0.53 0.69 0.82 0.98 1.34
Pipe Diameter
Description
42
FA.2.16 Hoses > 1m (3ft) (e.o. norm) Hoses > 1m (e.o. norm)
Description n.b. - mm 15 20 25 40 50 65 80 100 150 200 250 300
> 1m, e.o. Remove (all ratings) m 0.20 0.20 0.22 0.23 0.24 0.27 0.28 0.31 0.37 0.41 0.48 0.52
> 1m, e.o. Re-fit (all ratings) m 0.42 0.42 0.45 0.49 0.52 0.55 0.58 0.65 0.78 0.88 1.01 1.10
Pipe Diameter
Hoses > 3ft (e.o. norm)
Description n.b. - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4 " 6" 8" 10" 12"
> 3ft, e.o. Remove (all ratings) m 0.20 0.20 0.22 0.23 0.24 0.27 0.28 0.31 0.37 0.41 0.48 0.52
> 3ft, e.o. Re-fit (all ratings) m 0.42 0.42 0.45 0.49 0.52 0.55 0.58 0.65 0.78 0.88 1.01 1.10
Pipe Diameter
43
FA.2.17 Bellows
Bellows
n.b. - mm 15 20 25 40 50 65 80 100 150 200 250 300
n.b. - inch 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12"
Remove 150# No. 0.47 0.47 0.50 0.52 0.58 0.61 0.63 0.96 1.30 2.09 3.33 4.01
Remove 300# No. 0.47 0.51 0.61 0.67 0.98 1.05 1.13 1.29 1.97 2.87 4.22 5.11
Remove 600# No. 0.47 0.51 0.61 0.67 0.98 1.08 1.18 1.39 2.29 3.30 4.87 6.54
Remove 900# No. 0.47 0.51 0.61 0.67 1.14 1.24 1.35 1.56 2.67 3.79 5.36 7.03
pressure test 150# No. 0.63 0.63 0.63 0.67 0.76 0.77 0.82 1.42 1.72 2.01 3.72 4.01
Pressure test 300# No. 0.63 0.72 0.86 0.99 1.59 1.73 1.88 2.12 3.12 3.65 5.58 6.33
Pressure test 600# No. 0.63 0.72 0.86 0.99 1.59 1.78 1.99 2.35 3.82 4.57 6.97 9.35
Pressure test 900# No. 0.63 0.72 0.86 0.99 1.93 2.12 2.35 2.69 4.62 5.60 8.00 10.39
Re-fit 150# No. 0.59 0.59 0.63 0.66 0.75 0.78 0.81 1.21 1.66 2.76 4.32 5.26
Re-fit 300# No. 0.59 0.65 0.76 0.84 1.21 1.32 1.40 1.60 2.44 3.67 5.36 6.55
Re-fit 600# No. 0.59 0.65 0.76 0.84 1.21 1.35 1.46 1.73 2.83 4.19 6.13 8.24
Re-fit 900# No. 0.59 0.65 0.76 0.84 1.40 1.53 1.66 1.92 3.28 4.77 6.71 8.81
Pipe Diameter
Description
44
FA.2.18 Liquid Pulsation Dampers
Liquid Pulsation Dampers
n.e. 100mmover 100mm n.e. 150mm
n.e. 4"over 4" n.e. 6"
Bladder pressure check No. 0.20 0.20
Bladder pressure adjust No. 0.25 0.25
Bladder replace No. 0.35 0.75
Chamber External Diameter
Description Unit
FA.2.19 Plate Packs
Plate Packs
Description Unit n.e. 1 Teover 1 n.e.
2 Teover 2 n.e.
4 Teover 4 n.e.
6 Teover 6 n.e.
8 Teover 8 n.e.
10 Te
Remove / Re-fit No. 0.83 1.66 3.22 4.78 6.24 7.60
Total Plate Weight
45
FA.2.20 Ejectors
Ejectors
n.b. - mm 15 20 25 40 50 65 80 100 150 200 250 300
n.b. - inch 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12"
Remove 150# (Outlet) No. 0.73 0.73 0.76 0.78 0.84 0.87 0.89 1.22 1.56 2.35 3.59 4.27
Remove 300# (Outlet) No. 0.73 0.77 0.87 0.93 1.24 1.31 1.39 1.55 2.23 3.13 4.48 5.37
Remove 600# (Outlet) No. 0.73 0.77 0.87 0.93 1.24 1.34 1.44 1.65 2.55 3.56 5.13 6.80
Strip 150# (Outlet) No. 0.19 0.19 0.19 0.29 0.31 0.31 0.35 0.50 0.58 0.63 1.02 1.12
Strip 300# (Outlet) No. 0.19 0.21 0.25 0.37 0.51 0.58 0.60 0.69 0.91 1.02 1.50 1.67
Strip 600# (Outlet) No. 0.19 0.21 0.25 0.37 0.55 0.59 0.66 0.74 1.08 1.28 1.83 2.38
Rebuild 150# (Outlet) No. 0.17 0.17 0.17 0.17 0.20 0.20 0.20 0.54 0.61 0.71 1.14 1.20
Rebuild 300# (Outlet) No. 0.17 0.19 0.27 0.29 0.55 0.59 0.60 0.72 0.98 1.14 1.63 1.81
Rebuild 600# (Outlet) No. 0.17 0.19 0.27 0.29 0.55 0.51 0.62 0.78 1.10 1.39 2.00 2.51
Re-fit 150# (Outlet) No. 0.87 0.87 0.91 0.94 1.03 1.06 1.09 1.49 1.94 1.04 4.36 5.26
Re-fit 300# (Outlet) No. 0.87 0.87 0.91 0.94 1.03 1.06 1.09 1.49 1.94 1.04 5.60 6.46
Re-fit 600# (Outlet) No. 0.87 0.93 1.04 1.12 1.49 1.63 1.74 2.01 3.11 5.47 6.08 8.06
Outlet Pipe Diameter
Description
46
FA.2.21 Filters
Filters (Plenty Type)
n.b. - mm 25 40 50 80 100 150 200 250 300
n.b. - inch 1" 1 1/2" 2" 3" 4" 6" 8" 10" 12"
Remove, Overhaul & Re-fit 150# No. 0.70 0.70 0.70 0.70 1.30 1.40 1.60 3.10 3.10
Remove, Overhaul & Re-fit 300# No. 0.80 0.90 1.10 1.20 1.40 1.90 3.10 4.70 6.00
Remove, Overhaul & Re-fit 600# No. 0.80 0.90 1.10 1.20 1.90 3.10 4.60 6.00 7.10
Remove, Overhaul & Re-fit 900# No. 1.10 1.30 1.70 1.70 2.80 4.00 5.10 6.60 8.00
Remove, Overhaul & Re-fit 1500# No. 1.10 1.30 1.90 2.80 3.00 5.10 5.70 6.90 9.00
Pipe Diameter
Description
Filters (Bolted Lid Type)
n.b. - mm 25 40 50 80 100 150 200 250 300
n.b. - inch 1" 1 1/2" 2" 3" 4" 6" 8" 10" 12"
Remove, Overhaul & Re-fit 150# No. 0.79 0.79 0.83 0.83 1.56 1.74 1.99 3.86 3.98
Remove, Overhaul & Re-fit 300# No. 0.98 1.09 1.53 1.71 1.97 2.79 3.86 5.91 7.17
Remove, Overhaul & Re-fit 600# No. 0.98 1.09 1.53 1.77 2.43 3.98 5.38 7.52 9.45
Remove, Overhaul & Re-fit 900# No. 1.19 1.37 2.12 2.29 3.24 5.01 6.24 8.46 10.60
Remove, Overhaul & Re-fit 1500# No. 1.19 1.37 2.26 3.12 3.49 6.13 7.13 8.55 11.14
Pipe Diameter
Description
47
FB.1 Rotating Equipment Norms
FB.2.1 Single stage pumps
n.e. 50kw>50kw n.e
100kw
n.e. 68hp>68hp n.e
136hpChange element bundle complete with casing cover (use old impellor)
No. 4.00 4.60
Overhaul element bundle complete with casing cover No. 5.00 5.75
UnitDescription
Rating
Single stage pump with cartridge seal
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hp
Element bundle complete with casing cover - full overhaul No. 10.00 11.50 13.00
element bundle complete with casing cover - partial overhaul
No. 8.00 9.20 10.40
Rating
Single stage pump with single, component type seal
UnitDescription
48
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hpElement bundle complete with casing cover - full overhaul and barrier fluid vessel drain clean and refill
No. 12.00 13.80 15.60
Element bundle complete with casing cover - partial overhaul and barrier fluid vessel drain clean and refill
No. 10.00 11.50 13.00
Rating
Single stage pump with double component seal
UnitDescription
FB.2.2 Split horizontal pumps
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw>150kw
n.e.200kw>200kw n.e.
250kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hp>204hp
n.e.272hp>272 n.e.
340hp
Complete overhaul No. 20.00 23.00 26.00 32.00 38.00
Partial overhaul. Mech seal and bearing change. No. 14.00 16.10 18.20 22.70 27.20
Split horizontal pump with 2 single mechanical compo nent seals
UnitDescription
Rating
49
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw>150kw
n.e.200kw>200kw n.e.
250kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hp>204hp
n.e.272hp>272 n.e.
340hp
Complete overhaul No. 21.00 24.15 27.30 33.60 39.90
Partial overhaul. Mech seal and bearing change. No. 16.00 18.40 20.80 25.60 30.40
Split horizontal pump with 2 double mechanical compo nent seals
Description
Rating
Unit
FB.2.3 Split vertical pumps
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hp
Complete overhaul No. 35.00 40.25 45.50
Partial overhaul. Mech seal and bearing change. No. 11.00 12.65 14.30
UnitDescription
Rating
Split vertical pump with 2 double mechanical componen t seals
50
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hp
Complete overhaul No. 33.00 37.95 42.90
Partial overhaul. Mech seal and bearing change. No. 9.00 10.35 11.70
UnitDescription
Split vertical pump with 2 single mechanicalcomponent seals
Rating
FB.2.4 Pump Removal/Refit
Pump Removal/Refit
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw>150kw
n.e.200kw>200kw n.e.
250kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hp>204hp
n.e.272hp>272 n.e.
340hp
Vertical pump remove for overhaul No. 2.46 3.57 4.81 5.95
Vertical pump replace after overhaul No. 2.46 3.57 4.81 5.95
Horizontal pump remove for overhaul No. 2.16 2.80 3.60 4.40 5.19
Horizontal pump replace after overhaul No. 2.16 2.80 3.60 4.40 5.19
UnitDescription
Rating
51
FB.2.5 Coupling Variations
Coupling Variations
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw>150kw
n.e.200kw>200kw n.e.
250kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hp>204hp
n.e.272hp>272 n.e.
340hp
Metal Diaphragm 0.10 0.14 0.19 0.23 0.28
Elastomer Tyre (-0.1) (-0.12) (-0.15) (-0.17) (-0.20)
Jaw (-0.14) (-0.17) (-0.20) (-0.23) (-0.26)
UnitDescription
Rating
FB.2.6 Reciprocating dosing pump
Rating
n.e. 50kw
n.e. 68hp
Partial overhaul No. 3.00
UnitDescription
Reciprocating dosing pump
52
FB.2.7 Miscellaneous pump work Miscellaneous Pump Work.
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw>150kw
n.e.200kw>200kw n.e.
250kw>250kw n.e.
300kw
>300kw n.e.
350kw
>350kw n.e.
400kw>400kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hp>204hp
n.e.272hp>272 n.e.
340hp>340hp n.e.
408hp>408hp
n.e. 476hp>476hp
n.e. 544hp>544hp
Remove element bundle complete with casing cover No. 1.00 1.15 1.30 1.50
Refit element bundle complete with casing cover No. 0.75 0.86 0.98 1.10
Renew wear ring No. 0.70 1.00 1.30 1.60 1.90 2.20 2.50 2.80 3.10
Repair cartridge seal No. 1.10 1.50 1.95 2.40 2.85 3.30 3.75 4.20 4.65
Remove volute casing No. 1.90 2.50 3.25 4.00 4.75 5.50 6.25 7.00 7.75
Refit volute casing No. 1.90 2.50 3.25 4.00 4.75 5.50 6.25 7.00 7.75
Repack stuffing box No. 0.10 0.11 0.13 0.16 0.19 0.22 0.25 0.28 0.31
UnitDescription
Rating
53
Pump Lubrication
Rating
n.e.250kw
n.e. 340hp
Single seal No. 1.00
Single seal and gear coupling No. 1.50
Double seal No. 2.00
Double seal and gear coupling No. 2.50
Reciprocating dosing pump No. 0.50
UnitDescription
54
Reciprocating compressor
n.e. 170mm >170mm
n.e. 6inch >6 inch
Valve removal and refit No. 1.50 2.00
UnitDescription
Diameter mm
ne. 100 ltr>100ltr ne
200ltr>200ltr ne
300ltr>300ltr ne
400ltr
ne. 26 gal>26gal ne
52gal>52gal ne
78gal>78gal ne
104gal
Oil change No. 2.00 4.00 9.00 10.00
UnitDescription
Capacity liters
FB.2.8 Fin Fans Fin Fans
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw>150kw
n.e.200kw>200kw n.e.
250kw>250kw n.e.
300kw
>300kw n.e.
350kw
>350kw n.e.
400kw>400kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hp>204hp
n.e.272hp>272 n.e.
340hp>340hp n.e.
408hp>408hp
n.e. 476hp>476hp
n.e. 544hp>544hp
Replace bearings No. 1.80 2.20 2.60 3.20 3.80 4.40 5.00 5.60 6.20
Renew drive belts No. 0.48 0.56 0.65 0.80 0.95 1.10 1.25 1.40 1.55
Replace motor pulley No. 0.48 0.56 0.65 0.80 0.95 1.10 1.25 1.40 1.55
Replace fan pulley No. 2.48 2.86 3.25 4.00 4.75 5.50 6.25 7.00 7.75
UnitDescription
Rating
55
FB.2.9 Electric Motors Electric motors
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw>150kw
n.e.200kw>200kw n.e.
250kw>250kw n.e.
300kw
>300kw n.e.
350kw
>350kw n.e.
400kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hp>204hp
n.e.272hp>272 n.e.
340hp>340hp n.e.
408hp>408hp
n.e. 476hp>476hp
n.e. 544hp
Remove motor No. 2.16 2.80 3.60 4.40 5.19 6.00 6.80 7.60
Refit motor No. 2.16 2.80 3.60 4.40 5.19 6.00 6.80 7.60
Description Unit
Rating
FB.2.10 Alignment Alignment
n.e. 50kw>50kw n.e
100kw>100kw n.e
150kw>150kw
n.e.200kw>200kw n.e.
250kw>250kw n.e.
300kw
n.e. 68hp>68hp n.e
136hp>136hp n.e
204hp>204hp
n.e.272hp>272 n.e.
340hp>340hp n.e.
408hp
Align and adjust No. 2.10 2.28 2.50 2.71 3.18 3.61
UnitDescription
Rating
56
G.1 HVAC Norms
G.2.1 Square Galvanised Carbon Steel
Square or Rectangular Ductwork
FabricateUoM n.e. 1.5mm
thickover 1.5mmn.e. 2.0mm
thick
over 2mmn.e. 3mm
thick
over 3mmn.e. 5mm
thick
N.E. 1000mm girth m 0.67 1.79 2.70 3.74Over 1000mm n.e. 2000mm girth m 1.79 3.13 4.02 6.34Over 2000mm n.e. 3000mm girth m 4.03 5.41 6.33 9.71Over 3000mm n.e. 4000mm girth m 6.22 7.61 9.03 13.64Over 4000mm n.e. 5000mm girth m 7.79 9.85 11.69 17.65Over 5000mm n.e. 6000mm girth m 9.62 12.66 15.03 22.71Over 6000mm n.e. 7000mm girth m 11.77 16.47 19.55 29.53Over 7000mm n.e. 8000mm girth m 14.54 19.11 22.68 34.26
Fabricate Fittings
UoM E.O. for Bend
E.O. for Branch/tee
E.O. for Reducer
E.O. for Flexible
connection
E.O. for Bend
E.O. for Branch/tee
E.O. for Reducer
E.O. for Flexible
connection
E.O. for Bend
E.O. for Branch/te
e
E.O. for Reducer
E.O. for Flexible
connection
E.O. for Bend
E.O. for Branch/te
e
E.O. for Reducer
E.O. for Flexible
connection
N.E. 1000mm girth No 1.34 2.37 0.49 1.12 2.55 2.55 0.54 1.25 3.57 3.67 0.76 1.40 8.03 7.64 1.37 1.57Over 1000mm n.e. 2000mm girth No 1.70 2.64 0.58 1.21 3.36 2.86 0.63 1.70 4.36 3.55 0.78 2.39 9.16 4.97 1.32 3.37Over 2000mm n.e. 3000mm girth No 2.42 4.39 0.76 1.43 4.30 4.74 0.81 1.97 4.73 6.07 0.93 2.71 9.21 8.01 1.20 3.72Over 3000mm n.e. 4000mm girth No 3.94 5.77 0.98 2.15 5.50 6.62 1.03 2.46 6.05 7.95 1.18 2.82 11.81 10.49 1.54 3.23Over 4000mm n.e. 5000mm girth No 5.64 6.13 1.16 2.60 6.58 8.23 1.34 2.86 7.24 9.88 1.54 3.16 14.11 13.04 2.01 3.49Over 5000mm n.e. 6000mm girth No 6.49 8.68 1.34 3.49 7.20 11.14 1.43 3.58 7.93 13.37 1.65 3.67 15.45 17.65 2.14 3.77Over 6000mm n.e. 7000mm girth No 6.80 10.83 1.57 4.48 7.61 14.05 1.70 4.70 8.37 16.86 1.96 4.93 16.32 22.26 2.54 5.18Over 7000mm n.e. 8000mm girth No 7.38 13.47 1.75 5.24 8.19 16.83 1.92 5.64 9.01 20.19 2.21 6.07 17.57 26.65 2.88 6.54
over 2mm n.e. 3mm thick over 3mm n.e. 5mm thickn.e. 1.5mm thick over 1.5mm n.e. 2.0mm thick
57
Erect incl. in-line fittings & stiffeners
UoM n.e. 1.5mm thick
over 1.5mmn.e. 2.0mm
thick
over 2mmn.e. 3mm
thick
over 3mmn.e. 5mm
thick
N.E. 1000mm girth m 0.36 0.76 1.21 1.57Over 1000mm n.e. 2000mm girth m 0.76 1.30 1.88 2.69Over 2000mm n.e. 3000mm girth m 1.25 2.10 2.91 3.54Over 3000mm n.e. 4000mm girth m 1.97 2.91 3.85 4.21Over 4000mm n.e. 5000mm girth m 2.46 3.76 5.10 5.46Over 5000mm n.e. 6000mm girth m 3.04 4.88 6.76 8.23Over 6000mm n.e. 7000mm girth m 3.71 6.40 9.04 9.40Over 7000mm n.e. 8000mm girth m 4.61 7.38 10.16 14.95
58
G.2.2 Circular Galvanised Carbon Steel
Circular Ductwork
FabricateUoM n.e. 1.5mm
thickOver 1.5mm
n.e. 2mm thick
Over 2mmn.e. 3mm
thick
Over 3mmn.e. 5mm
thick
n.e. 200mm m 0.67 1.92 3.22 4.56Over 200mm n.e. 300mm m 1.21 2.46 3.71 5.15Over 300mm n.e. 400mm m 1.79 2.91 4.03 5.68Over 400mm n.e. 500mm m 2.33 3.36 4.43 6.80Over 500mm n.e. 600mm m 2.77 3.94 5.06 7.97Over 600mm n.e. 700mm m 3.31 4.34 5.33 9.13Over 700mm n.e. 800mm m 3.94 5.01 6.09 12.98Over 800mm n.e. 900mm m 4.56 5.55 6.49 14.01Over 900mm n.e. 1000mm m 4.97 6.09 7.20 14.63Over 1000mm n.e. 1100mm m 6.58 7.97 9.40 15.44Over 1100mm n.e. 1200mm m 7.20 8.86 10.52 15.89Over 1200mm n.e. 1300mm m 7.74 9.40 11.10 16.74
59
Fabricate in-line Fittings
UoM E.O. for Bend
E.O. for Branch/tee
E.O. for Reducer
E.O. for Flexible
connection
E.O. for Bend
E.O. for Branch/tee
E.O. for Reducer
E.O. for Flexible
connection
E.O. for Bend
E.O. for Branch/tee
E.O. for Reducer
E.O. for Flexible
connection
E.O. for Bend
E.O. for Branch/tee
E.O. for Reducer
E.O. for Flexible
connection
n.e. 200mm No 0.58 0.22 0.81 0.94 1.21 0.67 0.98 0.94 1.83 1.12 1.16 0.94 5.33 2.24 1.86 0.94Over 200mm n.e. 300mm No 0.90 0.40 1.57 1.16 2.15 0.81 2.73 1.16 2.46 1.16 3.89 1.16 5.55 2.42 7.01 1.16Over 300mm n.e. 400mm No 1.16 0.58 2.46 1.61 1.97 0.94 3.45 1.61 2.73 1.30 4.43 1.61 6.04 2.64 8.42 1.61Over 400mm n.e. 500mm No 1.43 0.76 3.00 1.83 2.19 1.16 3.98 1.83 3.00 1.57 4.97 1.83 6.49 3.04 9.35 1.83Over 500mm n.e. 600mm No 1.79 0.98 3.58 2.06 2.55 1.34 4.74 2.06 3.31 1.66 5.86 2.06 7.43 3.13 10.20 2.06Over 600mm n.e. 700mm No 2.10 1.12 4.21 2.33 2.82 1.52 5.19 2.33 3.49 1.97 6.13 2.33 7.97 3.40 11.05 2.33Over 700mm n.e. 800mm No 2.37 1.21 5.06 2.64 3.09 1.34 5.77 2.64 3.98 2.06 6.53 2.64 8.23 3.54 11.90 2.60Over 800mm n.e. 900mm No 2.69 1.48 5.37 3.04 3.54 2.10 6.40 3.04 4.34 2.69 7.38 3.04 9.08 3.71 12.71 3.04Over 900mm n.e. 1000mm No 3.00 1.48 6.00 3.40 3.85 2.24 7.03 3.40 4.70 3.04 8.01 2.95 9.31 4.12 13.34 3.40Over 1000mm n.e. 1100mm No 4.03 2.15 8.19 3.76 4.52 2.64 9.44 3.76 5.01 3.13 10.74 3.76 9.80 4.30 14.14 3.76Over 1100mm n.e. 1200mm No 4.43 2.42 8.73 4.07 4.88 2.95 10.16 4.07 5.28 3.54 11.59 4.07 10.34 4.65 14.90 4.03Over 1200mm n.e. 1300mm No 4.79 2.51 8.95 4.43 5.10 3.13 10.70 4.43 5.41 3.76 12.49 4.43 10.83 5.46 15.75 4.39
over 2mm n.e. 3mm thick over 3mm n.e. 5mm thickn.e. 1.5mm thick over 1.5mm n.e. 2.0mm thick
Erect incl. in-line fittings & stiffeners
UoM n.e. 1.5mm thick
Over 1.5mmn.e. 2mm
thick
Over 2mmn.e. 3mm
thick
Over 3mmn.e. 5mm
thick
n.e. 200mm m 0.36 0.85 1.43 1.52Over 200mm n.e. 300mm m 0.45 1.03 1.66 1.88Over 300mm n.e. 400mm m 0.85 1.34 1.83 2.01Over 400mm n.e. 500mm m 0.98 1.52 2.01 2.28Over 500mm n.e. 600mm m 1.16 1.70 2.28 2.46Over 600mm n.e. 700mm m 1.25 1.83 2.37 2.91Over 700mm n.e. 800mm m 1.30 2.06 2.82 4.30Over 800mm n.e. 900mm m 1.52 2.24 2.91 4.65Over 900mm n.e. 1000mm m 1.66 2.46 3.27 4.88Over 1000mm n.e. 1100mm m 2.19 3.22 4.21 5.15Over 1100mm n.e. 1200mm m 2.28 3.49 4.74 5.28Over 1200mm n.e. 1300mm m 2.42 3.71 4.97 5.59
60
G.2.3 Spiral Wound Galvanised Carbon Steel
Spirally Wound Ductwork
FabricateUoM
n.e. 200mm m 1.48Over 200mm n.e. 300mm m 1.66Over 300mm n.e. 400mm m 2.46Over 400mm n.e. 500mm m 2.91Over 500mm n.e. 600mm m 3.36Over 600mm n.e. 700mm m 3.67Over 700mm n.e. 800mm m 4.30Over 800mm n.e. 900mm m 5.28Over 900mm n.e. 1000mm m 5.73Over 1000mm n.e. 1100mm m 7.92Over 1100mm n.e. 1200mm m 8.50Over 1200mm n.e. 1300mm m 9.08
Erect incl. in-line fittings & stiffenersUoM
n.e. 200mm m 0.36Over 200mm n.e. 300mm m 0.45Over 300mm n.e. 400mm m 0.85Over 400mm n.e. 500mm m 0.98Over 500mm n.e. 600mm m 1.16Over 600mm n.e. 700mm m 1.25Over 700mm n.e. 800mm m 1.30Over 800mm n.e. 900mm m 1.52Over 900mm n.e. 1000mm m 1.66Over 1000mm n.e. 1100mm m 2.19Over 1100mm n.e. 1200mm m 2.35Over 1200mm n.e. 1300mm m 2.51
61
G.2.4 Fittings Galvanised Carbon Steel
Install Fittings to erected ductwork
UoM n.e. 0.20m2 over 0.20n.e. 0.50m2
over 0.50n.e. 1.00m2
over 1n.e. 2m2
over 2n.e. 3m2
over 3n.e. 4m2
Grille No 0.58 0.76 0.94 1.16 1.34 1.79Attenuator No 1.79 2.37 3.58 4.74 5.33 6.71Access door No 0.58 0.76 0.94 1.16 1.34 1.79Stop end No 0.58 0.76 0.94 1.16 1.34 1.79Bird mesh screen No 0.58 0.76 0.94 1.16 1.34 1.79Weather louvre No 0.76 0.81 1.12 1.48 1.66 2.10Plenum No 1.79 2.37 3.58 4.74 5.33 6.71
Cross sectional area
62
G.2.5 Equipment Galvanised Carbon Steel
Install Equipment
UoM n.e. 0.025 each
over 0.025 n.e. 0.050
each
over 0.050 n.e. 0.10
each
over 0.1 n.e. 0.50 each
over 0.50 n.e. 1.00
each
over 1.00 n.e. 2.00
each
over 2.00 n.e. 5.00
each
over 5.00 n.e. 10.00
each
Fire/gas damper No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Volume control damper No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Non-return/backdr damper No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Pressure relief damper No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Isolation damper No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Supply fan No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Extract fan No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Vent fan No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Filter No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Moisture eliminator No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Humidifier No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Diffuser No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Heater battery No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Filter coalescer No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Cooling coil No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Heating coil No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Plenum box No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66Control panel No 1.79 2.37 3.58 4.74 7.16 11.90 23.85 47.66
Tonnes
63
G.2.6 Supports
Galvanised Carbon Steel
Steel Supports
Fabricate & ErectUoM
N.E. 10kg each Kg 0.58Over 10 n.e. 25kg each Kg 0.49Over 25 n.e. 50kg each Kg 0.40Over 50 n.e. 100kg each Kg 0.36Over 100 n.e. 250kg each Kg 0.31
UnistrutUoM
Assemble & erect m 0.36
64
H.1 Mechanical Pipework Norms
H.2.1 Pipework Fabrication Sch10 Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch 10
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 28" 30" 32"n.b. - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 700 750 800
Work Operation W.T. - mm 2.11 2.77 2.77 2.77 3.05 3.05 3.05 3.40 6.35 6.35 6.35 6.35 6.35 6.35 6.35 6.35 7.92 7.92 7.92Square Cut Unit hrs 0.07 0.07 0.11 0.14 0.18 0.22 0.26 0.33 0.43 0.54 0.65 0.76 0.86 0.98 1.08 1.19 1.48 1.73 1.87 2.00
Mitre Cut Unit hrs 0.07 0.11 0.14 0.18 0.22 0.26 0.29 0.36 0.50 0.65 0.79 0.94 1.08 1.22 1.37 1.51 1.90 2.22 2.34 2.49
Pulled Bend Unit hrs 0.18 0.18 0.22 0.29 0.40 0.58 0.76 1.12
Thread End Unit hrs 0.11 0.15 0.17 0.18 0.20 0.24 0.27 0.34
Make Screwed Joint Unit hrs 0.11 0.11 0.11 0.14 0.18 0.22 0.26 0.36
Butt Weld Unit hrs 0.44 0.61 0.82 1.05 1.26 1.45 1.61 1.96 2.50 3.06 3.61 4.17 4.71 5.27 5.82 6.38 7.64 8.91 10.52 11.22
Weld Neck Flange Weld Unit hrs 0.48 0.64 0.90 1.12 1.38 1.54 1.68 2.00 2.54 3.10 3.65 4.21 4.75 5.31 5.86 6.42 7.64 8.91 10.45 11.14
Slip On Flange Weld Unit hrs 0.36 0.44 0.61 0.76 0.93 1.03 1.12 1.32 1.67 2.03 2.38 2.74 3.10 3.46 3.81 4.17 5.04 5.88 6.89 7.35
Mitre Butt Weld Unit hrs 0.55 0.85 1.07 1.40 1.67 1.92 2.14 2.60 3.42 4.22 5.04 5.85 6.66 7.47 8.29 9.10 10.63 12.40 14.36 15.32
90 Branch Weld Unreinforced Unit hrs 0.81 1.09 1.40 1.82 2.26 2.57 2.86 3.47 4.50 5.53 6.55 7.58 8.61 9.55 10.58 11.61 13.74 16.03 18.35 19.57
90 Branch Weld Reinforced Unit hrs 1.54 2.10 2.69 3.50 4.33 4.90 5.47 6.62 8.56 10.51 12.46 14.38 16.35 18.13 20.07 22.02 26.01 30.34 34.83 37.15
Angle Branch Weld Unreinforced Unit hrs 1.00 1.40 1.78 2.26 2.71 3.06 3.39 4.07 5.30 6.52 7.75 8.97 10.20 11.46 12.65 13.86 16.90 19.71 22.49 23.99
Angle Branch Weld Reinforced Unit hrs 1.93 2.69 3.42 4.33 5.21 5.86 6.50 7.78 10.10 12.39 14.71 17.00 19.32 21.69 23.93 26.22 31.89 37.20 42.64 45.48
Weld Weldolet Unit hrs 0.86 1.15 1.48 1.81 2.14 2.40 2.65 3.15 3.90 4.65 5.30 6.14 7.02 7.84 8.66 9.48 11.36
Weld Latrolet Unit hrs 0.98 1.32 1.73 2.14 2.54 2.88 3.19 3.86 5.02 6.18 7.33 8.49
Weld Elbolet Unit hrs 1.16 1.62 2.12 2.62 3.11 3.50 3.86 4.61 5.50 6.39
Socket weld Unit hrs 0.20 0.25 0.33 0.41 0.52 0.58 0.64 0.75 0.98 1.22
65
H.2.2 Pipework Fabrication Sch20 Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch 20
n.b - inches 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36"n.b. - mm 200 250 300 350 400 450 500 600 650 700 750 800 900
Work Operation W.T. - mm 6.35 6.35 6.35 7.92 7.92 7.92 9.52 9.52 12.70 12.70 12.70 12.70 12.70Square Cut Unit hrs 0.54 0.65 0.76 0.86 0.98 1.08 1.19 1.48 1.60 1.73 1.87 2.00 2.27
Mitre Cut Unit hrs 0.65 0.79 0.94 1.08 1.22 1.37 1.51 1.90 2.06 2.22 2.34 2.49 2.78
Pulled Bend Unit hrs
Thread End Unit hrs
Make Screwed Joint Unit hrs
Butt Weld Unit hrs 3.06 3.61 4.17 4.71 5.27 5.82 6.38 7.64 8.28 8.91 10.52 11.22 12.66
Weld Neck Flange Weld Unit hrs 3.10 3.65 4.21 4.75 5.31 5.86 6.42 7.64 8.28 8.91 10.45 11.14 12.51
Slip On Flange Weld Unit hrs 2.03 2.38 2.74 3.10 3.46 3.81 4.17 5.04 5.46 5.88 6.89 7.35 8.24
Mitre Butt Weld Unit hrs 4.22 5.04 5.85 6.66 7.47 8.29 9.10 10.63 11.52 12.40 14.36 15.32 17.16
90 Branch Weld Unreinforced Unit hrs 5.53 6.55 7.58 8.61 9.55 10.58 11.61 13.74 14.89 16.03 18.35 19.57 22.07
90 Branch Weld Reinforced Unit hrs 10.51 12.46 14.38 16.35 18.13 20.07 22.02 26.01 28.18 30.34 34.83 37.15 41.86
Angle Branch Weld Unreinforced Unit hrs 6.52 7.75 8.97 10.20 11.46 12.65 13.86 16.90 18.30 19.71 22.49 23.99 26.95
Angle Branch Weld Reinforced Unit hrs 12.39 14.71 17.00 19.32 21.69 23.93 26.22 31.89 34.55 37.20 42.64 45.48 51.13
Weld Weldolet Unit hrs 4.65 5.30 6.14 7.02 7.84 8.66 9.48 11.36
Weld Latrolet Unit hrs 6.18 7.33 8.49
Weld Elbolet Unit hrs 6.39
Socket weld Unit hrs 1.22
66
H.2.3 Pipework Fabrication Sch30 Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch 30
n.b - inches 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36"n.b - mm 200 250 300 350 400 450 500 600 650 700 750 800 900
Work Operation W.T. - mm 7.03 7.79 8.38 9.52 9.52 11.12 12.70 14.30 15.88 15.88 15.88 15.88 15.88Square Cut Unit hrs 0.54 0.65 0.76 0.86 0.98 1.08 1.19 1.78 1.92 2.07 2.25 2.40 2.73
Mitre Cut Unit hrs 0.65 0.79 0.94 1.08 1.22 1.37 1.51 2.28 2.48 2.67 2.80 2.99 3.33
Pulled Bend Unit hrs
Thread End Unit hrs
Make Screwed Joint Unit hrs
Butt Weld Unit hrs 3.06 3.61 4.17 4.71 5.27 6.39 7.00 9.86 10.68 11.50 12.35 13.18 14.86
Weld Neck Flange Weld Unit hrs 3.10 3.65 4.21 4.75 5.31 6.43 7.04 9.86 10.68 11.50 12.28 13.10 14.72
Slip On Flange Weld Unit hrs 2.03 2.38 2.74 3.10 3.46 4.19 4.58 6.44 6.98 7.51 8.01 8.55 9.60
Mitre Butt Weld Unit hrs 4.22 5.04 5.85 6.66 7.47 8.97 9.84 13.65 14.78 15.92 16.96 18.10 20.27
90 Branch Weld Unreinforced Unit hrs 5.53 6.55 7.58 8.61 9.55 11.24 12.33 17.57 19.03 20.50 22.02 23.49 26.48
90 Branch Weld Reinforced Unit hrs 10.51 12.46 14.38 16.35 18.13 21.39 23.47 33.36 36.14 38.92 41.79 44.58 50.23
Angle Branch Weld Unreinforced Unit hrs 6.52 7.75 8.97 10.20 11.46 13.48 14.78 21.63 23.43 25.23 26.99 28.78 32.34
Angle Branch Weld Reinforced Unit hrs 12.39 14.71 17.00 19.32 21.69 25.60 28.05 40.97 44.38 47.80 51.17 54.58 61.36
Weld Weldolet Unit hrs 4.65 5.30 6.14 7.02 7.84 9.57 10.48 15.07 16.33 17.58
Weld Latrolet Unit hrs 6.18 7.33 8.49
Weld Elbolet Unit hrs 6.39
Socket Weld Unit hrs 1.22
67
H.2.4 Pipework Fabrication Std wall Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Std Wall
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36" 42" 48"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 650 700 750 800 900 1100 1200
Work Operation W.T. - mm 2.76 2.87 3.37 3.68 3.91 5.15 5.48 6.02 7.11 8.17 9.27 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52
Square Cut Unit hrs 0.07 0.07 0.11 0.14 0.18 0.22 0.26 0.33 0.43 0.54 0.65 0.76 0.86 0.98 1.08 1.19 1.48 1.60 1.73 1.87 2.00 2.27 2.66 3.06
Mitre Cut Unit hrs 0.07 0.11 0.14 0.18 0.22 0.26 0.29 0.36 0.50 0.65 0.79 0.94 1.08 1.22 1.37 1.51 1.90 2.06 2.22 2.34 2.49 2.78 3.21 3.64
Pulled Bend Unit hrs 0.18 0.18 0.22 0.29 0.40 0.58 0.76 1.12
Thread End Unit hrs 0.11 0.15 0.17 0.18 0.20 0.24 0.27 0.34
Make Screwed Joint Unit hrs 0.11 0.11 0.11 0.14 0.18 0.22 0.26 0.36
Butt Weld Unit hrs 0.44 0.61 0.82 1.05 1.26 1.45 1.61 1.96 2.50 3.06 3.61 4.17 4.71 5.27 5.82 6.38 7.64 8.28 8.91 9.58 10.21 11.52 13.46 15.40
Weld Neck Flange Weld Unit hrs 0.48 0.64 0.90 1.12 1.38 1.54 1.68 2.00 2.54 3.10 3.65 4.21 4.75 5.31 5.86 6.42 7.64 8.28 8.91 9.50 10.14 11.38 13.24 15.11
Slip On Flange Weld Unit hrs 0.36 0.44 0.61 0.76 0.93 1.03 1.12 1.32 1.67 2.03 2.38 2.74 3.10 3.46 3.81 4.17 5.04 5.46 5.88 6.26 6.68 7.50 8.72 9.95
Mitre Butt Weld Unit hrs 0.55 0.85 1.07 1.40 1.67 1.92 2.14 2.60 3.42 4.22 5.04 5.85 6.66 7.47 8.29 9.10 10.63 11.52 12.40 13.22 14.10 15.79 18.38 20.96
90 Branch Weld Unreinforced Unit hrs 0.81 1.09 1.40 1.82 2.26 2.57 2.86 3.47 4.50 5.53 6.55 7.58 8.61 9.55 10.58 11.61 13.74 14.89 16.03 17.22 18.37 20.71 24.19 27.68
90 Branch Weld Reinforced Unit hrs 1.54 2.10 2.69 3.50 4.33 4.90 5.47 6.62 8.56 10.51 12.46 14.38 16.35 18.13 20.07 22.02 26.01 28.18 30.34 32.58 34.75 39.15 45.72 52.30
Angle Branch Weld Unreinforced Unit hrs 1.00 1.40 1.78 2.26 2.71 3.06 3.39 4.07 5.30 6.52 7.75 8.97 10.20 11.46 12.65 13.86 16.90 18.30 19.71 21.08 22.49 25.26 29.45 33.62
Angle Branch Weld Reinforced Unit hrs 1.93 2.69 3.42 4.33 5.21 5.86 6.50 7.78 10.10 12.39 14.71 17.00 19.32 21.69 23.93 26.22 31.89 34.55 37.20 39.82 42.48 47.75 55.69 63.61
Weld Weldolet Unit hrs 0.86 1.15 1.48 1.81 2.14 2.40 2.65 3.15 3.90 4.65 5.30 6.14 7.02 7.84 8.66 9.48 11.36 12.31 13.25
Weld Latrolet Unit hrs 0.98 1.32 1.73 2.14 2.54 2.88 3.19 3.86 5.02 6.18 7.33 8.49
Weld Elbolet Unit hrs 1.16 1.62 2.12 2.62 3.11 3.50 3.86 4.61 5.50 6.39
Socket Weld Unit hrs 0.20 0.25 0.33 0.41 0.52 0.58 0.64 0.75 0.98 1.22
68
H.2.5 Pipework Fabrication Sch40 Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch 40
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 650 700 750 800 900
Work Operation W.T. - mm 2.76 2.87 3.38 3.68 3.91 5.16 5.49 6.01 7.11 8.18 9.27 10.31 11.10 12.70 14.27 15.06 17.45 17.45 17.45 17.45 17.45 19.05Square Cut Unit hrs 0.07 0.07 0.11 0.14 0.18 0.22 0.26 0.33 0.43 0.54 0.65 0.76 0.86 0.98 1.30 1.43 1.78 1.92 2.07 2.25 2.40 2.73
Mitre Cut Unit hrs 0.07 0.11 0.14 0.18 0.22 0.26 0.29 0.36 0.50 0.65 0.79 0.94 1.08 1.22 1.64 1.81 2.28 2.48 2.67 2.80 2.99 3.33
Pulled Bend Unit hrs 0.18 0.18 0.22 0.29 0.40 0.58 0.76 1.12
Thread End Unit hrs 0.11 0.15 0.17 0.18 0.20 0.24 0.27 0.34
Make Screwed Joint Unit hrs 0.11 0.11 0.11 0.14 0.18 0.22 0.26 0.36
Butt Weld Unit hrs 0.44 0.61 0.82 1.05 1.26 1.45 1.61 1.96 2.50 3.06 3.61 4.58 5.18 5.79 7.51 8.23 10.94 11.85 12.77 13.72 14.64 16.51
Weld Neck Flange Weld Unit hrs 0.48 0.64 0.90 1.12 1.38 1.54 1.68 2.00 2.54 3.10 3.65 4.62 5.22 5.83 7.55 8.27 10.94 11.85 12.77 13.65 14.56 16.37
Slip On Flange Weld Unit hrs 0.36 0.44 0.61 0.76 0.93 1.03 1.12 1.32 1.67 2.03 2.38 3.02 3.40 3.80 4.86 5.32 7.17 7.77 8.36 8.92 9.52 10.68
Mitre Butt Weld Unit hrs 0.55 0.85 1.07 1.40 1.67 1.92 2.14 2.60 3.42 4.22 5.04 6.34 7.22 8.09 10.60 11.63 14.97 16.22 17.47 18.62 19.87 22.26
90 Branch Weld Unreinforced Unit hrs 0.81 1.09 1.40 1.82 2.26 2.57 2.86 3.47 4.50 5.53 6.55 8.08 9.16 10.15 13.48 14.80 18.87 20.44 22.02 23.65 25.23 28.45
90 Branch Weld Reinforced Unit hrs 1.54 2.10 2.69 3.50 4.33 4.90 5.47 6.62 8.56 10.51 12.46 15.36 17.46 19.32 25.67 28.16 35.97 38.96 41.96 45.06 48.07 54.16
Angle Branch Weld Unreinforced Unit hrs 1.00 1.40 1.78 2.26 2.71 3.06 3.39 4.07 5.30 6.52 7.75 9.57 10.88 12.21 16.18 17.74 23.26 25.20 27.14 29.03 30.96 34.79
Angle Branch Weld Reinforced Unit hrs 1.93 2.69 3.42 4.33 5.21 5.86 6.50 7.78 10.10 12.39 14.71 18.20 20.68 23.20 30.72 33.66 44.24 47.92 51.61 55.25 58.93 66.26
Weld Weldolet Unit hrs 0.86 1.15 1.48 1.81 2.14 2.40 2.65 3.15 3.90 4.65 5.30 6.80 7.76 8.67 11.49 12.58 16.81 18.21 19.61
Weld Latrolet Unit hrs 0.98 1.32 1.73 2.14 2.54 2.88 3.19 3.86 5.02 6.18 7.33 9.40
Weld Elbolet Unit hrs 1.16 1.62 2.12 2.62 3.11 3.50 3.86 4.61 5.50 6.39
Socket Weld Unit hrs 0.20 0.25 0.33 0.41 0.52 0.58 0.64 0.75 0.98 1.22
69
H.2.6 Pipework Fabrication Sch60 Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch 60
n.b - inches 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 10.31 12.70 14.27 15.06 16.66 19.05 20.62 24.59Square Cut Unit hrs 0.54 0.65 0.91 1.04 1.17 1.30 1.43 1.78
Mitre Cut Unit hrs 0.65 0.79 1.12 1.30 1.47 1.64 1.81 2.28
Pulled Bend Unit hrs
Thread End Unit hrs
Make Screwed Joint Unit hrs
Butt Weld Unit hrs 3.37 3.97 5.38 6.09 7.56 8.34 10.23 13.83
Weld Neck Flange Weld Unit hrs 3.41 4.01 5.42 6.13 7.60 8.38 10.27 13.83
Slip On Flange Weld Unit hrs 2.24 2.62 3.50 3.95 4.91 5.41 6.64 9.10
Mitre Butt Weld Unit hrs 4.59 5.47 7.49 8.53 10.45 11.58 13.99 18.50
90 Branch Weld Unreinforced Unit hrs 5.90 6.98 9.69 11.00 13.05 14.44 17.10 22.33
90 Branch Weld Reinforced Unit hrs 11.25 13.32 18.43 20.95 24.93 27.59 32.78 42.88
Angle Branch Weld Unreinforced Unit hrs 6.96 8.27 11.48 13.05 15.75 17.40 20.66 27.60
Angle Branch Weld Reinforced Unit hrs 13.27 15.75 21.84 24.81 30.04 33.15 39.51 52.91
Weld Weldolet Unit hrs 5.16 5.87 8.15 9.32 11.61 12.82 15.78 21.42
Weld Latrolet Unit hrs 6.84 8.11 11.27
Weld Elbolet Unit hrs 7.10
Socket Weld Unit hrs 1.22
70
H.2.7 Pipework Fabrication SchXS Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch XS
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 650 700 750 800 900
Work Operation W.T. - mm 3.73 3.91 4.55 5.08 5.54 7.01 7.62 8.56 10.97 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70Square Cut Unit hrs 0.07 0.07 0.11 0.14 0.18 0.22 0.26 0.33 0.43 0.54 0.65 0.76 0.86 0.98 1.08 1.19 1.48 1.60 1.73 1.87 2.00 2.27
Mitre Cut Unit hrs 0.07 0.11 0.14 0.18 0.22 0.26 0.29 0.36 0.50 0.65 0.79 0.94 1.08 1.22 1.37 1.51 1.90 2.06 2.22 2.34 2.49 2.78
Pulled Bend Unit hrs 0.18 0.18 0.22 0.29 0.40 0.58 0.76 1.12
Thread End Unit hrs 0.11 0.15 0.17 0.18 0.20 0.24 0.27 0.34
Make Screwed Joint Unit hrs 0.11 0.11 0.11 0.14 0.18 0.22 0.26 0.36
Butt Weld Unit hrs 0.44 0.61 0.82 1.05 1.26 1.45 1.61 1.96 2.76 3.37 3.97 4.58 5.18 5.79 6.39 7.00 8.39 9.09 9.79 10.52 11.22 12.66
Weld Neck Flange Weld Unit hrs 0.48 0.64 0.90 1.12 1.38 1.54 1.68 2.00 2.80 3.41 4.01 4.62 5.22 5.83 6.43 7.04 8.39 9.09 9.79 10.45 11.14 12.51
Slip On Flange Weld Unit hrs 0.36 0.44 0.61 0.76 0.93 1.03 1.12 1.32 1.84 2.24 2.62 3.02 3.40 3.80 4.19 4.58 5.54 6.00 6.47 6.89 7.35 8.24
Mitre Butt Weld Unit hrs 0.55 0.85 1.07 1.40 1.67 1.92 2.14 2.60 3.72 4.59 5.47 6.34 7.22 8.09 8.97 9.84 11.55 12.51 13.47 14.36 15.32 17.16
90 Branch Weld Unreinforced Unit hrs 0.81 1.09 1.40 1.82 2.26 2.57 2.86 3.47 4.80 5.90 6.98 8.08 9.16 10.15 11.24 12.33 14.64 15.86 17.08 18.35 19.57 22.07
90 Branch Weld Reinforced Unit hrs 1.54 2.10 2.69 3.50 4.33 4.90 5.47 6.62 9.18 11.25 13.32 15.36 17.46 19.32 21.39 23.47 27.80 30.12 32.44 34.83 37.15 41.86
Angle Branch Weld Unreinforced Unit hrs 1.00 1.40 1.78 2.26 2.71 3.06 3.39 4.07 5.67 6.96 8.27 9.57 10.88 12.21 13.48 14.78 18.02 19.52 21.03 22.49 23.99 26.95
Angle Branch Weld Reinforced Unit hrs 1.93 2.69 3.42 4.33 5.21 5.86 6.50 7.78 10.83 13.27 15.75 18.20 20.68 23.20 25.60 28.05 34.14 36.99 39.83 42.64 45.48 51.13
Weld Weldolet Unit hrs 0.86 1.15 1.48 1.81 2.14 2.40 2.65 3.15 4.34 5.16 5.87 6.80 7.76 8.67 9.57 10.48 12.56 13.60 14.65
Weld Latrolet Unit hrs 0.98 1.32 1.73 2.14 2.54 2.88 3.19 3.86 5.55 6.84 8.11 9.40
Weld Elbolet Unit hrs 1.16 1.62 2.12 2.62 3.11 3.50 3.86 4.61 6.13 7.10
Socket Weld Unit hrs 0.20 0.25 0.33 0.41 0.52 0.58 0.64 0.75 0.98 1.22
71
H.2.8 Pipework Fabrication Sch80 Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch 80
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 3.73 3.91 4.55 5.08 5.54 7.01 7.62 8.56 10.97 12.70 15.06 17.45 19.05 21.41 23.80 26.19 30.94Square Cut Unit hrs 0.07 0.07 0.11 0.14 0.18 0.22 0.26 0.33 0.43 0.54 0.78 0.91 1.04 1.17 1.30 1.79 2.22
Mitre Cut Unit hrs 0.07 0.11 0.14 0.18 0.22 0.26 0.29 0.36 0.50 0.65 0.95 1.12 1.30 1.47 1.64 2.27 2.86
Pulled Bend Unit hrs 0.18 0.18 0.22 0.29 0.40 0.58 0.76 1.12
Thread End Unit hrs 0.11 0.15 0.17 0.18 0.20 0.24 0.27 0.34
Make Screwed Joint Unit hrs 0.11 0.11 0.11 0.14 0.18 0.22 0.26 0.36
Butt Weld Unit hrs 0.44 0.61 0.82 1.05 1.26 1.45 1.61 1.96 2.76 3.37 4.66 5.98 6.76 8.47 10.54 13.82 18.80
Weld Neck Flange Weld Unit hrs 0.48 0.64 0.90 1.12 1.38 1.54 1.68 2.00 2.80 3.41 4.70 6.02 6.80 8.51 10.58 13.86 18.80
Slip On Flange Weld Unit hrs 0.36 0.44 0.61 0.76 0.93 1.03 1.12 1.32 1.84 2.24 3.04 3.89 4.40 5.51 6.87 8.91 12.31
Mitre Butt Weld Unit hrs 0.55 0.85 1.07 1.40 1.67 1.92 2.14 2.60 3.72 4.59 6.47 8.21 9.34 11.53 14.20 18.76 25.03
90 Branch Weld Unreinforced Unit hrs 0.81 1.09 1.40 1.82 2.26 2.57 2.86 3.47 4.80 5.90 8.38 10.41 11.80 14.10 16.99 22.82 30.04
90 Branch Weld Reinforced Unit hrs 1.54 2.10 2.69 3.50 4.33 4.90 5.47 6.62 9.18 11.25 15.98 19.85 22.56 27.02 32.68 43.86 57.86
Angle Branch Weld Unreinforced Unit hrs 1.00 1.40 1.78 2.26 2.71 3.06 3.39 4.07 5.67 6.96 9.93 12.35 14.04 17.08 20.62 27.66 37.17
Angle Branch Weld Reinforced Unit hrs 1.93 2.69 3.42 4.33 5.21 5.86 6.50 7.78 10.83 13.27 18.90 23.57 26.78 32.69 39.59 53.05 71.49
Weld Weldolet Unit hrs 0.86 1.15 1.48 1.81 2.14 2.40 2.65 3.15 4.34 5.16 7.04 9.10 10.40 13.07 16.35 21.73 29.62
Weld Latrolet Unit hrs 0.98 1.32 1.73 2.14 2.54 2.88 3.19 3.86 5.55 6.84 9.73 12.59
Weld Elbolet Unit hrs 1.16 1.62 2.12 2.62 3.11 3.50 3.86 4.61 6.13 7.10
Socket Weld Unit hrs 0.20 0.25 0.33 0.41 0.52 0.58 0.64 0.75 0.98 1.22
72
H.2.9 Pipework Fabrication Sch100 Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch 100
n.b - inches 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 15.06 18.24 21.41 23.80 26.19 29.36 32.51 38.89Square Cut Unit hrs 0.65 0.78 0.91 1.04 1.46 1.62 1.79 2.22
Mitre Cut Unit hrs 0.78 0.95 1.12 1.30 1.84 2.05 2.27 2.86
Pulled Bend Unit hrs
Thread End Unit hrs
Make Screwed Joint Unit hrs
Butt Weld Unit hrs 3.96 5.19 6.71 8.56 11.45 14.34 16.95 23.29
Weld Neck Flange Weld Unit hrs 4.00 5.23 6.75 8.60 11.49 14.38 16.99 23.29
Slip On Flange Weld Unit hrs 2.59 3.38 4.37 5.58 7.38 9.28 10.98 15.33
Mitre Butt Weld Unit hrs 5.43 7.09 9.07 11.48 15.47 19.16 22.45 30.52
90 Branch Weld Unreinforced Unit hrs 7.08 9.01 11.27 13.94 18.82 22.80 26.43 35.43
90 Branch Weld Reinforced Unit hrs 13.50 17.24 21.56 26.84 36.17 43.98 51.08 68.63
Angle Branch Weld Unreinforced Unit hrs 8.35 10.68 13.39 16.65 22.86 27.76 32.24 43.93
Angle Branch Weld Reinforced Unit hrs 15.93 20.41 25.67 32.00 43.88 53.46 62.20 85.00
Weld Weldolet Unit hrs 6.19 7.86 10.24 13.28 18.00 22.61 26.74 36.81
Weld Latrolet Unit hrs 8.20 10.87 14.18
Weld Elbolet Unit hrs 8.52
Socket Weld Unit hrs 1.32
73
H.2.10 Pipework Fabrication Sch120 Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch 120
n.b - inches 4" 6" 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 100 150 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 11.10 12.70 18.24 21.41 2.54 27.76 30.94 34.93 38.10 46.02Square Cut Unit hrs 0.33 0.52 0.65 0.78 0.91 1.30 1.46 1.62 1.79 2.22
Mitre Cut Unit hrs 0.36 0.60 0.78 0.95 1.12 1.62 1.84 2.05 2.27 2.86
Pulled Bend Unit hrs 1.12
Thread End Unit hrs 0.34
Make Screwed Joint Unit hrs 0.36
Butt Weld Unit hrs 2.16 3.24 4.41 5.82 7.58 10.25 13.01 15.49 18.20 26.66
Weld Neck Flange Weld Unit hrs 2.20 3.28 4.45 5.86 7.62 10.29 13.05 15.53 18.24 26.66
Slip On Flange Weld Unit hrs 1.45 2.13 2.88 3.80 4.95 6.62 8.42 10.04 11.81 17.59
Mitre Butt Weld Unit hrs 2.85 4.40 5.96 7.85 10.11 13.84 17.32 20.52 23.93 34.64
90 Branch Weld Unreinforced Unit hrs 3.72 5.77 7.61 9.76 12.30 17.08 20.61 24.12 27.88 39.47
90 Branch Weld Reinforced Unit hrs 7.11 11.01 14.57 18.75 23.62 32.86 39.76 46.63 53.96 76.71
Angle Branch Weld Unreinforced Unit hrs 4.35 6.80 8.99 11.59 14.65 20.39 25.13 29.43 34.07 49.00
Angle Branch Weld Reinforced Unit hrs 8.35 12.99 17.20 22.23 28.18 39.16 48.42 56.81 65.86 95.14
Weld Weldolet Unit hrs 3.52 5.20 6.93 8.84 11.61 16.13 20.50 24.44 28.74 42.21
Weld Latrolet Unit hrs 4.28 6.66 9.16 12.24 16.08
Weld Elbolet Unit hrs 5.17 7.36 9.54
Socket Weld Unit hrs 0.75 1.07 1.32
74
H.2.11 Pipework Fabrication Sch140 Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch 140
n.b - inches 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 20.62 2.54 28.58 31.75 36.50 39.67 44.45 52.37Square Cut Unit hrs 0.65 0.78 1.14 1.30 1.46 1.62 1.79 2.22
Mitre Cut Unit hrs 0.78 0.95 1.40 1.62 1.84 2.05 2.27 2.86
Pulled Bend Unit hrs
Thread End Unit hrs
Make Screwed Joint Unit hrs
Butt Weld Unit hrs 4.95 6.58 9.07 11.65 15.09 17.78 20.71 30.03
Weld Neck Flange Weld Unit hrs 4.99 6.62 9.11 11.69 15.13 17.82 20.75 30.03
Slip On Flange Weld Unit hrs 3.24 4.30 5.86 7.54 9.79 11.55 13.47 19.85
Mitre Butt Weld Unit hrs 6.61 8.76 12.18 15.50 19.78 23.23 26.89 38.76
90 Branch Weld Unreinforced Unit hrs 8.26 10.67 15.07 18.74 23.00 26.77 30.76 43.50
90 Branch Weld Reinforced Unit hrs 15.87 20.56 28.91 36.19 44.55 51.91 59.74 84.79
Angle Branch Weld Unreinforced Unit hrs 9.76 12.68 17.94 22.42 28.16 32.78 37.73 54.07
Angle Branch Weld Reinforced Unit hrs 18.74 24.41 34.48 43.23 54.48 63.51 73.19 105.28
Weld Weldolet Unit hrs 7.82 10.03 14.10 18.37 23.82 28.11 32.75 47.60
Weld Latrolet Unit hrs 10.32 13.89 19.54
Weld Elbolet Unit hrs 10.77
Socket Weld Unit hrs 1.32
75
H.2.12 Pipework Fabrication Sch160 Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch 160
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 4.75 5.54 6.35 7.14 8.71 9.53 11.10 13.49 18.24 23.01 28.58 33.32 35.71 40.46 43.64 49.99 59.51Square Cut Unit hrs 0.07 0.07 0.11 0.14 0.18 0.22 0.26 0.39 0.52 0.65 0.97 1.14 1.30 1.46 1.62 1.79 2.22
Mitre Cut Unit hrs 0.07 0.11 0.14 0.18 0.22 0.26 0.29 0.43 0.60 0.78 1.19 1.40 1.62 1.84 2.05 2.27 2.86
Pulled Bend Unit hrs 0.18 0.18 0.22 0.29 0.40 0.58 0.76 1.12
Thread End Unit hrs 0.11 0.15 0.17 0.18 0.20 0.24 0.27 0.37
Make Screwed Joint Unit hrs 0.11 0.11 0.11 0.14 0.18 0.22 0.26 0.36
Butt Weld Unit hrs 0.44 0.61 0.82 1.05 1.26 1.45 1.78 2.54 3.61 4.95 7.87 11.14 13.52 16.13 20.36 23.83 31.53
Weld Neck Flange Weld Unit hrs 0.48 0.64 0.90 1.12 1.38 1.54 1.86 2.58 3.65 4.99 7.91 11.18 13.56 16.17 20.40 23.87 31.53
Slip On Flange Weld Unit hrs 0.36 0.44 0.61 0.76 0.93 1.03 1.24 1.68 2.37 3.24 5.09 7.23 8.78 10.48 13.26 15.54 20.85
Mitre Butt Weld Unit hrs 0.55 0.85 1.07 1.40 1.67 1.92 2.35 3.36 4.85 6.61 10.55 14.64 17.72 21.01 26.28 30.58 40.59
90 Branch Weld Unreinforced Unit hrs 0.81 1.09 1.40 1.82 2.26 2.57 3.08 4.46 6.21 8.26 13.07 17.54 20.96 24.20 29.74 34.37 45.30
90 Branch Weld Reinforced Unit hrs 1.54 2.10 2.69 3.50 4.33 4.90 5.89 8.53 11.91 15.87 25.16 33.80 40.63 46.94 57.86 66.95 88.38
Angle Branch Weld Unreinforced Unit hrs 1.00 1.40 1.78 2.26 2.71 3.06 3.64 5.22 7.32 9.76 15.53 20.93 25.14 29.67 36.54 42.30 56.32
Angle Branch Weld Reinforced Unit hrs 1.93 2.69 3.42 4.33 5.21 5.86 6.99 10.02 14.04 18.74 29.87 40.46 48.65 57.51 71.04 82.34 109.78
Weld Weldolet Unit hrs 0.86 1.15 1.48 1.81 2.14 2.40 2.97 4.23 5.84 7.82 12.18 17.36 21.36 25.49 32.24 37.76 50.00
Weld Latrolet Unit hrs 0.98 1.32 1.73 2.14 2.54 2.88 3.55 5.13 7.44 10.32 16.87 24.07
Weld Elbolet Unit hrs 1.16 1.62 2.12 2.62 3.11 3.50 4.36 6.21 8.27 10.77
Socket Weld Unit hrs 0.20 0.25 0.33 0.41 0.52 0.58 0.64 0.82 1.07 1.32
76
H.2.13 Pipework Fabrication SchXXS Pipework Fabrication Material Carbon Steel
Standard Norms Location Workshop
Pipe Schedule Sch XXS
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300
Work Operation W.T. - mm 7.47 7.82 9.09 10.16 11.07 14.02 15.24 17.12 21.95 22.23 25.40 25.40Square Cut Unit hrs 0.07 0.07 0.11 0.14 0.18 0.27 0.31 0.39 0.52 0.65 0.78 0.91
Mitre Cut Unit hrs 0.07 0.11 0.14 0.18 0.22 0.31 0.35 0.43 0.60 0.78 0.95 1.12
Pulled Bend Unit hrs 0.18 0.18 0.22 0.29 0.40 0.58 0.76 1.12
Thread End Unit hrs 0.11 0.15 0.17 0.18 0.20 0.26 0.30 0.37
Make Screwed Joint Unit hrs 0.11 0.11 0.11 0.14 0.18 0.22 0.26 0.36
Butt Weld Unit hrs 0.44 0.61 0.82 1.17 1.41 1.90 2.10 2.83 4.06 4.95 6.58 7.58
Weld Neck Flange Weld Unit hrs 0.48 0.64 0.90 1.24 1.53 1.98 2.17 2.87 4.10 4.99 6.62 7.62
Slip On Flange Weld Unit hrs 0.36 0.44 0.61 0.84 1.03 1.31 1.42 1.87 2.67 3.24 4.30 4.95
Mitre Butt Weld Unit hrs 0.55 0.85 1.07 1.54 1.85 2.50 2.77 3.72 5.39 6.61 8.76 10.11
90 Branch Weld Unreinforced Unit hrs 0.81 1.09 1.40 1.96 2.43 3.31 3.69 4.82 6.75 8.26 10.67 12.30
90 Branch Weld Reinforced Unit hrs 1.54 2.10 2.69 3.79 4.68 6.35 7.07 9.25 12.99 15.87 20.56 23.62
Angle Branch Weld Unreinforced Unit hrs 1.00 1.40 1.78 2.43 2.92 3.94 4.37 5.63 7.96 9.76 12.68 14.65
Angle Branch Weld Reinforced Unit hrs 1.93 2.69 3.42 4.68 5.63 7.58 8.39 10.83 15.31 18.74 24.41 28.18
Weld Weldolet Unit hrs 0.86 1.15 1.48 2.05 2.42 3.24 3.57 4.76 6.61 7.82 10.03 11.61
Weld Latrolet Unit hrs 0.98 1.32 1.73 2.39 2.85 3.86 4.26 5.73 8.38 10.32 13.89 16.08
Weld Elbolet Unit hrs 1.16 1.62 2.12 2.97 3.53 4.74 5.23 7.02 9.38 10.77
Socket Weld Unit hrs 0.20 0.25 0.33 0.41 0.52 0.63 0.69 0.82 1.07 1.32
77
H.2.14 Pipework Erection Sch10 Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch 10
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 28" 30" 32"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 700 750 800
Work Operation W.T. - mm 2.11 2.77 2.77 2.77 3.05 3.05 3.05 3.40 6.35 6.35 6.35 6.35 6.35 6.35 6.35 6.35 7.92 7.92 7.92Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.42 0.42 0.45 0.49 0.52 0.55 0.58 0.65 0.78 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94 2.03 2.07 2.12
2A Erect Pipe (double random) hrs/metre 0.30 0.30 0.32 0.36 0.39 0.41 0.42 0.45 0.52 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43 1.47 1.49 1.51
1B Erect Pipe (single random & spooled ) hrs/foot 0.13 0.13 0.14 0.15 0.16 0.17 0.18 0.20 0.24 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.59 0.62 0.63 0.65
2B Erect Pipe (double random) hrs/foot 0.09 0.09 0.10 0.11 0.12 0.13 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43 0.45 0.45 0.46
3 Install Valves, steam traps, strainers and the like Unit hrs 0.26 0.26 0.30 0.32 0.36 0.40 0.42 0.49 0.81 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24 10.42 11.02 12.20
4 Install Control Valve or similar Unit hrs 0.35 0.35 0.40 0.43 0.48 0.53 0.57 0.66 1.09 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31 13.90 14.69 16.27
5 Install Blank Flange Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.56 0.58 0.60
6 Install Spec Plate or similar Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.56 0.58 0.60
7 Make Flange Joint 150 # Unit hrs 0.17 0.17 0.17 0.17 0.19 0.19 0.19 0.36 0.42 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46 3.13 3.47 3.85
8 Make Flange Joint 300 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.46 0.49 0.55 0.81 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47 4.25 4.64 5.03
9 Make Flange Joint 600 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.48 0.52 0.62 1.01 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31 4.83 5.09 5.24
10 Make Flange Joint 900 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.57 0.62 0.71 1.23 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.58 0.65 0.78 1.43 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
12 Make Flange Joint 2500 # Unit hrs 0.17 0.20 0.24 0.27 0.54 0.61 0.68 0.85 1.66 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.10 0.10 0.13 0.19 0.26 0.30 0.32 0.39 0.50 0.58 0.68 0.78 0.91 1.04 1.17 1.30 1.53 1.79 1.92 2.04
14 Mitre Cut Unit hrs 0.10 0.13 0.17 0.20 0.23 0.29 0.34 0.45 0.59 0.73 0.88 1.02 1.16 1.30 1.45 1.59 1.80 2.10 2.25 2.40
15 Pulled Bend Unit hrs 0.19 0.19 0.23 0.31 0.42 0.60 0.78 1.14
16 Thread End Unit hrs 0.12 0.18 0.19 0.21 0.24 0.28 0.31 0.37
17 Make Screwed Joint Unit hrs 0.12 0.12 0.12 0.15 0.19 0.24 0.28 0.38
18 Butt Weld Unit hrs 0.51 0.66 0.88 1.12 1.38 1.53 1.66 2.02 2.60 3.17 3.74 4.32 4.92 5.54 6.14 6.75 8.01 10.07 11.11 11.86
19 Weld Neck Flange Weld Unit hrs 0.54 0.73 0.94 1.19 1.44 1.59 1.72 2.08 2.66 3.23 3.81 4.38 4.99 5.61 6.21 6.82 7.97 10.00 11.01 11.74
20 Slip On Flange Weld Unit hrs 0.41 0.50 0.64 0.86 1.07 1.20 1.30 1.50 1.88 2.22 2.59 2.94 3.34 3.73 4.13 4.51 5.35 6.71 7.39 7.88
21 Mitre Butt Weld Unit hrs 0.68 0.91 1.19 1.48 1.76 2.01 2.24 2.71 3.51 4.30 5.10 5.90 6.70 7.49 8.31 9.12 10.83 13.49 14.82 15.82
22 90 Branch Weld Unreinforced Unit hrs 0.87 1.22 1.58 1.96 2.35 2.66 2.96 3.57 4.59 5.58 6.59 7.59 8.63 9.66 10.70 11.74 14.31 17.53 19.14 20.42
23 Angle Branch weld Unreinforced Unit hrs 1.07 1.50 1.93 2.36 2.78 3.17 3.54 4.30 5.57 6.82 8.09 9.33 10.63 11.93 13.23 14.53 17.37 21.31 23.28 24.84
24 Weld Weldolet Unit hrs 0.93 1.23 1.54 1.87 2.21 2.46 2.69 3.18 4.07 4.92 5.80 6.67 7.65 8.60 9.53 10.47 12.33
25 Weld Latrolet Unit hrs 1.10 1.53 1.94 2.40 2.84 3.20 3.53 4.20 5.47 6.72 7.98 9.23
26 Weld Elbolet Unit hrs 1.26 1.76 2.26 2.79 3.32 3.71 4.08 4.83 6.11 7.35
27 Socket Weld Unit hrs 0.21 0.26 0.35 0.50 0.64 0.72 0.78 0.93 1.23 1.50
78
H.2.15 Pipework Erection Sch20 Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch 20
n.b - inches 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36"n.b - mm 200 250 300 350 400 450 500 600 650 700 750 800 900
Work Operation W.T. - mm 6.35 6.35 6.35 7.92 7.92 7.92 9.52 9.52 12.70 12.70 12.70 12.70 12.70Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94 1.99 2.03 2.07 2.12 2.20
2A Erect Pipe (double random) hrs/metre 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43 1.45 1.47 1.49 1.51 1.56
1B Erect Pipe (single random & spooled ) hrs/foot 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.59 0.61 0.62 0.63 0.65 0.67
2B Erect Pipe (double random) hrs/foot 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43 0.44 0.45 0.45 0.46 0.47
3 Install Valves, steam traps, strainers and the like Unit hrs 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24 9.83 10.42 11.02 12.20 14.58
4 Install Control Valve or similar Unit hrs 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31 13.10 13.90 14.69 16.27 19.44
5 Install Blank Flange Unit hrs 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65
6 Install Spec Plate or similar Unit hrs 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65
7 Make Flange Joint 150 # Unit hrs 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46 2.80 3.13 3.47 3.85 4.60
8 Make Flange Joint 300 # Unit hrs 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47 3.86 4.25 4.64 5.03 5.80
9 Make Flange Joint 600 # Unit hrs 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31 4.57 4.83 5.09 5.24 5.54
10 Make Flange Joint 900 # Unit hrs 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
12 Make Flange Joint 2500 # Unit hrs 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.58 0.68 0.78 0.91 1.04 1.17 1.30 1.53 1.66 1.79 1.92 2.04 2.30
14 Mitre Cut Unit hrs 0.73 0.88 1.02 1.16 1.30 1.45 1.59 1.80 1.95 2.10 2.25 2.40 2.69
15 Pulled Bend Unit hrs
16 Thread End Unit hrs
17 Make Screwed Joint Unit hrs
18 Butt Weld Unit hrs 3.17 3.74 4.32 4.92 5.54 6.14 6.75 8.01 9.04 10.07 11.11 11.86 13.36
19 Weld Neck Flange Weld Unit hrs 3.23 3.81 4.38 4.99 5.61 6.21 6.82 7.97 8.98 10.00 11.01 11.74 13.20
20 Slip On Flange Weld Unit hrs 2.22 2.59 2.94 3.34 3.73 4.13 4.51 5.35 6.03 6.71 7.39 7.88 8.86
21 Mitre Butt Weld Unit hrs 4.30 5.10 5.90 6.70 7.49 8.31 9.12 10.83 12.16 13.49 14.82 15.82 17.81
22 90 Branch Weld Unreinforced Unit hrs 5.58 6.59 7.59 8.63 9.66 10.70 11.74 14.31 15.92 17.53 19.14 20.42 22.96
23 Angle Branch weld Unreinforced Unit hrs 6.82 8.09 9.33 10.63 11.93 13.23 14.53 17.37 19.34 21.31 23.28 24.84 27.94
24 Weld Weldolet Unit hrs 4.92 5.80 6.67 7.65 8.60 9.53 10.47 12.33
25 Weld Latrolet Unit hrs 6.72 7.98 9.23
26 Weld Elbolet Unit hrs 7.35
27 Socket Weld Unit hrs 1.50
79
H.2.16 Pipework Erection Sch30 Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch 30
n.b - inches 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36"n.b - mm 200 250 300 350 400 450 500 600 650 700 750 800 900
Work Operation W.T. - mm 7.03 7.79 8.38 9.52 9.52 11.12 12.70 14.30 15.88 15.88 15.88 15.88 15.88Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94 1.99 2.03 2.07 2.12 2.20
2A Erect Pipe (double random) hrs/metre 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43 1.45 1.47 1.49 1.51 1.56
1B Erect Pipe (single random & spooled ) hrs/foot 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.59 0.61 0.62 0.63 0.65 0.67
2B Erect Pipe (double random) hrs/foot 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43 0.44 0.45 0.45 0.46 0.47
3 Install Valves, steam traps, strainers and the like Unit hrs 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24 9.83 10.42 11.02 12.20 14.58
4 Install Control Valve or similar Unit hrs 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31 13.10 13.90 14.69 16.27 19.44
5 Install Blank Flange Unit hrs 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65
6 Install Spec Plate or similar Unit hrs 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65
7 Make Flange Joint 150 # Unit hrs 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46 2.80 3.13 3.47 3.85 4.60
8 Make Flange Joint 300 # Unit hrs 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47 3.86 4.25 4.64 5.03 5.80
9 Make Flange Joint 600 # Unit hrs 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31 4.57 4.83 5.09 5.24 5.54
10 Make Flange Joint 900 # Unit hrs 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
12 Make Flange Joint 2500 # Unit hrs 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.58 0.68 0.78 0.91 1.04 1.17 1.30 1.83 1.99 2.14 2.30 2.45 2.76
14 Mitre Cut Unit hrs 0.73 0.88 1.02 1.16 1.30 1.45 1.59 2.39 2.60 2.80 2.94 3.13 3.49
15 Pulled Bend Unit hrs
16 Thread End Unit hrs
17 Make Screwed Joint Unit hrs
18 Butt Weld Unit hrs 3.17 3.74 4.32 4.92 5.54 6.80 7.48 10.25 11.12 11.99 12.85 13.72 15.46
19 Weld Neck Flange Weld Unit hrs 3.23 3.81 4.38 4.99 5.61 6.86 7.54 10.22 11.07 11.91 12.76 13.61 15.30
20 Slip On Flange Weld Unit hrs 2.22 2.59 2.94 3.34 3.73 4.56 4.99 6.80 7.36 7.93 8.49 9.05 10.18
21 Mitre Butt Weld Unit hrs 4.30 5.10 5.90 6.70 7.49 9.04 9.90 13.81 14.96 16.11 17.27 18.43 20.75
22 90 Branch Weld Unreinforced Unit hrs 5.58 6.59 7.59 8.63 9.66 11.45 12.56 18.18 19.69 21.21 22.72 24.23 27.25
23 Angle Branch weld Unreinforced Unit hrs 6.82 8.09 9.33 10.63 11.93 14.18 15.58 22.12 23.95 25.79 27.62 29.46 33.14
24 Weld Weldolet Unit hrs 4.92 5.80 6.67 7.65 8.60 10.58 11.62 16.16
25 Weld Latrolet Unit hrs 6.72 7.98 9.23
26 Weld Elbolet Unit hrs 7.35
27 Socket Weld Unit hrs 1.50
80
H.2.17 Pipework Erection Std wall Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Std Wall
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36" 42" 48"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 650 700 750 800 900 1100 1200
Work Operation W.T. - mm 2.76 2.87 3.37 3.68 3.91 5.15 5.48 6.02 7.11 8.17 9.27 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.42 0.42 0.45 0.49 0.52 0.55 0.58 0.65 0.78 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94 1.99 2.03 2.07 2.12 2.20 2.33 2.46
2A Erect Pipe (double random) hrs/metre 0.30 0.30 0.32 0.36 0.39 0.41 0.42 0.45 0.52 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43 1.45 1.47 1.49 1.51 1.56 1.62 1.68
1B Erect Pipe (single random & spooled ) hrs/foot 0.13 0.13 0.14 0.15 0.16 0.17 0.18 0.20 0.24 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.59 0.61 0.62 0.63 0.65 0.67 0.71 0.752B Erect Pipe (double random) hrs/foot 0.09 0.09 0.10 0.11 0.12 0.13 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43 0.44 0.45 0.45 0.46 0.47 0.49 0.51
3 Install Valves, steam traps, strainers and the likeUnit hrs 0.26 0.26 0.30 0.32 0.36 0.40 0.42 0.49 0.81 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24 9.83 10.42 11.02 12.20 14.58 18.14 21.71
4 Install Control Valve or similar Unit hrs 0.35 0.35 0.40 0.43 0.48 0.53 0.57 0.66 1.09 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31 13.10 13.90 14.69 16.27 19.44 24.19 28.945 Install Blank Flange Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65 0.71 0.78
6 Install Spec Plate or similar Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65 0.71 0.78
7 Make Flange Joint 150 # Unit hrs 0.17 0.17 0.17 0.17 0.19 0.19 0.19 0.36 0.42 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46 2.80 3.13 3.47 3.85 4.60 5.74 7.00
8 Make Flange Joint 300 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.46 0.49 0.55 0.81 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47 3.86 4.25 4.64 5.03 5.809 Make Flange Joint 600 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.48 0.52 0.62 1.01 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31 4.57 4.83 5.09 5.24 5.54
10 Make Flange Joint 900 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.57 0.62 0.71 1.23 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.58 0.65 0.78 1.43 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.1812 Make Flange Joint 2500 # Unit hrs 0.17 0.20 0.24 0.27 0.54 0.61 0.68 0.85 1.66 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.10 0.10 0.13 0.19 0.26 0.30 0.32 0.39 0.50 0.58 0.68 0.78 0.91 1.04 1.17 1.30 1.53 1.66 1.79 1.92 2.04 2.30 2.69 3.08
14 Mitre Cut Unit hrs 0.10 0.13 0.17 0.20 0.23 0.29 0.34 0.45 0.59 0.73 0.88 1.02 1.16 1.30 1.45 1.59 1.99 2.16 2.33 2.46 2.61 2.92 3.37 3.82
15 Pulled Bend Unit hrs 0.19 0.19 0.23 0.31 0.42 0.60 0.78 1.1416 Thread End Unit hrs 0.12 0.18 0.19 0.21 0.24 0.28 0.31 0.37
17 Make Screwed Joint Unit hrs 0.12 0.12 0.12 0.15 0.19 0.24 0.28 0.38
18 Butt Weld Unit hrs 0.51 0.66 0.88 1.12 1.38 1.53 1.66 2.02 2.60 3.17 3.74 4.32 4.92 5.54 6.14 6.75 8.01 8.69 9.36 10.04 10.73 12.09 14.13 16.1719 Weld Neck Flange Weld Unit hrs 0.54 0.73 0.94 1.19 1.44 1.59 1.72 2.08 2.66 3.23 3.81 4.38 4.99 5.61 6.21 6.82 7.97 8.63 9.29 9.95 10.61 11.92 13.90 15.88
20 Slip On Flange Weld Unit hrs 0.41 0.50 0.64 0.86 1.07 1.20 1.30 1.50 1.88 2.22 2.59 2.94 3.34 3.73 4.13 4.51 5.35 5.79 6.24 6.68 7.12 8.01 9.34 10.66
21 Mitre Butt Weld Unit hrs 0.68 0.91 1.19 1.48 1.76 2.01 2.24 2.71 3.51 4.30 5.10 5.90 6.70 7.49 8.31 9.12 10.83 11.74 12.64 13.55 14.46 16.29 19.02 21.7622 90 Branch Weld Unreinforced Unit hrs 0.87 1.22 1.58 1.96 2.35 2.66 2.96 3.57 4.59 5.58 6.59 7.59 8.63 9.66 10.70 11.74 14.31 15.50 16.69 17.88 19.07 21.44 25.01 28.58
23 Angle Branch weld Unreinforced Unit hrs 1.07 1.50 1.93 2.36 2.78 3.17 3.54 4.30 5.57 6.82 8.09 9.33 10.63 11.93 13.23 14.53 17.37 18.82 20.26 21.70 23.15 26.04 30.36 34.70
24 Weld Weldolet Unit hrs 0.93 1.23 1.54 1.87 2.21 2.46 2.69 3.18 4.07 4.92 5.80 6.67 7.65 8.60 9.53 10.47 12.33
25 Weld Latrolet Unit hrs 1.10 1.53 1.94 2.40 2.84 3.20 3.53 4.20 5.47 6.72 7.98 9.2326 Weld Elbolet Unit hrs 1.26 1.76 2.26 2.79 3.32 3.71 4.08 4.83 6.11 7.35
27 Socket Weld Unit hrs 0.21 0.26 0.32 0.50 0.64 0.72 0.78 0.93 1.23 1.50
81
H.2.18 Pipework Erection Sch40 Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch 40
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 650 700 750 800 900
Work Operation W.T. - mm 2.76 2.87 3.38 3.68 3.91 5.16 5.49 6.01 7.11 8.18 9.27 10.31 11.10 12.70 14.27 15.06 17.45 17.45 17.45 17.45 17.45 19.05Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.42 0.42 0.45 0.49 0.52 0.55 0.58 0.65 0.78 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94 1.99 2.03 2.07 2.12 2.20
2A Erect Pipe (double random) hrs/metre 0.30 0.30 0.32 0.36 0.39 0.41 0.42 0.45 0.52 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43 1.45 1.47 1.49 1.51 1.56
1B Erect Pipe (single random & spooled ) hrs/foot 0.13 0.13 0.14 0.15 0.16 0.17 0.18 0.20 0.24 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.59 0.61 0.62 0.63 0.65 0.67
2B Erect Pipe (double random) hrs/foot 0.09 0.09 0.10 0.11 0.12 0.13 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43 0.44 0.45 0.45 0.46 0.47
3 Install Valves, steam traps, strainers and the likeUnit hrs 0.26 0.26 0.30 0.32 0.36 0.40 0.42 0.49 0.81 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24 9.83 10.42 11.02 12.20 14.58
4 Install Control Valve or similar Unit hrs 0.35 0.35 0.40 0.43 0.48 0.53 0.57 0.66 1.09 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31 13.10 13.90 14.69 16.27 19.44
5 Install Blank Flange Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65
6 Install Spec Plate or similar Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65
7 Make Flange Joint 150 # Unit hrs 0.17 0.17 0.17 0.17 0.19 0.19 0.19 0.36 0.42 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46 2.80 3.13 3.47 3.85 4.60
8 Make Flange Joint 300 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.46 0.49 0.55 0.81 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47 3.86 4.25 4.64 5.03 5.80
9 Make Flange Joint 600 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.48 0.52 0.62 1.01 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31 4.57 4.83 5.09 5.24 5.54
10 Make Flange Joint 900 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.57 0.62 0.71 1.23 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.58 0.65 0.78 1.43 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
12 Make Flange Joint 2500 # Unit hrs 0.17 0.20 0.24 0.27 0.54 0.61 0.68 0.85 1.66 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms
13 Square Cut Unit hrs 0.10 0.10 0.13 0.19 0.26 0.30 0.32 0.39 0.50 0.58 0.68 0.78 0.91 1.04 1.40 1.56 1.83 1.99 2.14 2.30 2.45 2.76
14 Mitre Cut Unit hrs 0.10 0.13 0.17 0.20 0.23 0.29 0.34 0.45 0.59 0.73 0.88 1.02 1.16 1.30 1.74 1.91 2.40 2.60 2.80 2.94 3.14 3.50
15 Pulled Bend Unit hrs 0.19 0.19 0.23 0.31 0.42 0.60 0.78 1.14
16 Thread End Unit hrs 0.12 0.18 0.19 0.21 0.24 0.28 0.31 0.37
17 Make Screwed Joint Unit hrs 0.12 0.12 0.12 0.15 0.19 0.24 0.28 0.38
18 Butt Weld Unit hrs 0.51 0.66 0.88 1.12 1.38 1.53 1.66 2.02 2.60 3.17 3.74 4.79 5.46 6.14 7.89 8.67 11.65 12.64 13.62 14.61 15.59 17.57
19 Weld Neck Flange Weld Unit hrs 0.54 0.73 0.94 1.19 1.44 1.59 1.72 2.08 2.66 3.23 3.81 4.85 5.52 6.20 7.95 8.74 11.62 12.58 13.55 14.51 15.48 17.40
20 Slip On Flange Weld Unit hrs 0.41 0.50 0.64 0.86 1.07 1.20 1.30 1.50 1.88 2.22 2.59 3.26 3.70 4.13 5.23 5.72 7.74 8.38 9.02 9.67 10.31 11.59
21 Mitre Butt Weld Unit hrs 0.68 0.91 1.19 1.48 1.76 2.01 2.24 2.71 3.51 4.30 5.10 6.44 7.31 8.17 10.68 11.71 15.48 16.77 18.07 19.36 20.66 23.26
22 90 Branch Weld Unreinforced Unit hrs 0.87 1.22 1.58 1.96 2.35 2.66 2.96 3.57 4.59 5.58 6.59 8.13 9.24 10.34 13.59 14.91 19.85 21.51 23.16 24.81 26.46 29.76
23 Angle Branch weld Unreinforced Unit hrs 1.07 1.50 1.93 2.36 2.78 3.17 3.54 4.30 5.57 6.82 8.09 10.00 11.39 12.79 16.83 18.48 24.21 26.22 28.23 30.24 32.25 36.28
24 Weld Weldolet Unit hrs 0.93 1.23 1.54 1.87 2.21 2.46 2.69 3.18 4.07 4.92 5.80 7.40 8.50 9.55 12.48 13.72 18.39
25 Weld Latrolet Unit hrs 1.10 1.53 1.94 2.40 2.84 3.20 3.53 4.20 5.47 6.72 7.98 10.26
26 Weld Elbolet Unit hrs 1.26 1.76 2.26 2.79 3.32 3.71 4.08 4.83 6.11 7.35
27 Socket Weld Unit hrs 0.21 0.26 0.32 0.50 0.64 0.72 0.78 0.93 1.23 1.50
82
H.2.19 Pipework Erection Sch60 Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch 60
n.b - inches 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 10.31 12.70 14.27 15.06 16.66 19.05 20.62 24.59Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94
2A Erect Pipe (double random) hrs/metre 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43
1B Erect Pipe (single random & spooled ) hrs/foot 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.59
2B Erect Pipe (double random) hrs/foot 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43
3 Install Valves, steam traps, strainers and the likeUnit hrs 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24
4 Install Control Valve or similar Unit hrs 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31
5 Install Blank Flange Unit hrs 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
6 Install Spec Plate or similar Unit hrs 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
7 Make Flange Joint 150 # Unit hrs 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46
8 Make Flange Joint 300 # Unit hrs 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47
9 Make Flange Joint 600 # Unit hrs 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31
10 Make Flange Joint 900 # Unit hrs 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
12 Make Flange Joint 2500 # Unit hrs 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.58 0.68 0.93 1.09 1.24 1.40 1.56 1.83
14 Mitre Cut Unit hrs 0.73 0.88 1.22 1.39 1.56 1.74 1.91 2.39
15 Pulled Bend Unit hrs
16 Thread End Unit hrs
17 Make Screwed Joint Unit hrs
18 Butt Weld Unit hrs 3.51 4.15 5.55 6.32 8.10 8.97 11.12 14.92
19 Weld Neck Flange Weld Unit hrs 3.57 4.21 5.61 6.39 8.16 9.04 11.19 14.88
20 Slip On Flange Weld Unit hrs 2.46 2.87 3.73 4.24 5.38 5.95 7.34 9.93
21 Mitre Butt Weld Unit hrs 4.69 5.57 7.51 8.53 10.66 11.80 14.36 19.38
22 90 Branch Weld Unreinforced Unit hrs 5.98 7.06 9.77 11.08 13.40 14.83 17.71 23.76
23 Angle Branch weld Unreinforced Unit hrs 7.31 8.66 11.86 13.52 16.58 18.40 22.04 29.09
24 Weld Weldolet Unit hrs 5.47 6.45 8.74 10.03 12.84 14.22 17.64 23.62
25 Weld Latrolet Unit hrs 7.46 8.87 12.11
26 Weld Elbolet Unit hrs 8.22
27 Socket Weld Unit hrs 1.50
83
H.2.20 Pipework Erection SchXS Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch XS
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 650 700 750 800 900
Work Operation W.T. - mm 3.73 3.91 4.55 5.08 5.54 7.01 7.62 8.56 10.97 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.42 0.42 0.45 0.49 0.52 0.55 0.58 0.65 0.78 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94 1.99 2.03 2.07 2.12 2.20
2A Erect Pipe (double random) hrs/metre 0.30 0.30 0.32 0.36 0.39 0.41 0.42 0.45 0.52 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43 1.45 1.47 1.49 1.51 1.56
1B Erect Pipe (single random & spooled ) hrs/foot 0.13 0.13 0.14 0.15 0.16 0.17 0.18 0.20 0.24 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.59 0.61 0.62 0.63 0.65 0.67
2B Erect Pipe (double random) hrs/foot 0.09 0.09 0.10 0.11 0.12 0.13 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43 0.44 0.45 0.45 0.46 0.47
3 Install Valves, steam traps, strainers and the likeUnit hrs 0.26 0.26 0.30 0.32 0.36 0.40 0.42 0.49 0.81 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24 9.83 10.42 11.02 12.20 14.58
4 Install Control Valve or similar Unit hrs 0.35 0.35 0.40 0.43 0.48 0.53 0.57 0.66 1.09 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31 13.10 13.90 14.69 16.27 19.44
5 Install Blank Flange Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65
6 Install Spec Plate or similar Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65
7 Make Flange Joint 150 # Unit hrs 0.17 0.17 0.17 0.17 0.19 0.19 0.19 0.36 0.42 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46 2.80 3.13 3.47 3.85 4.60
8 Make Flange Joint 300 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.46 0.49 0.55 0.81 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47 3.86 4.25 4.64 5.03 5.80
9 Make Flange Joint 600 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.48 0.52 0.62 1.01 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31 4.57 4.83 5.09 5.24 5.54
10 Make Flange Joint 900 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.57 0.62 0.71 1.23 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.58 0.65 0.78 1.43 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
12 Make Flange Joint 2500 # Unit hrs 0.17 0.20 0.24 0.27 0.54 0.61 0.68 0.85 1.66 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.10 0.10 0.13 0.19 0.26 0.30 0.32 0.39 0.50 0.58 0.68 0.78 0.91 1.04 1.17 1.30 1.53 1.66 1.79 1.92 2.04 2.30
14 Mitre Cut Unit hrs 0.10 0.13 0.17 0.20 0.23 0.29 0.34 0.45 0.59 0.73 0.88 1.02 1.16 1.30 1.45 1.59 1.80 2.17 2.33 2.45 2.62 2.91
15 Pulled Bend Unit hrs 0.19 0.19 0.23 0.31 0.42 0.60 0.78 1.14
16 Thread End Unit hrs 0.12 0.18 0.19 0.21 0.24 0.28 0.31 0.37
17 Make Screwed Joint Unit hrs 0.12 0.12 0.12 0.15 0.19 0.24 0.28 0.38
18 Butt Weld Unit hrs 0.51 0.66 0.88 1.12 1.38 1.53 1.66 2.02 2.88 3.51 4.15 4.79 5.46 6.14 6.80 7.48 8.85 9.60 10.36 11.11 11.86 13.36
19 Weld Neck Flange Weld Unit hrs 0.54 0.73 0.94 1.19 1.44 1.59 1.72 2.08 2.94 3.57 4.21 4.85 5.52 6.20 6.86 7.54 8.82 9.55 10.28 11.01 11.74 13.20
20 Slip On Flange Weld Unit hrs 0.41 0.50 0.64 0.86 1.07 1.20 1.30 1.50 2.08 2.46 2.87 3.26 3.70 4.13 4.56 4.99 5.92 6.41 6.90 7.39 7.88 8.86
21 Mitre Butt Weld Unit hrs 0.68 0.91 1.19 1.48 1.76 2.01 2.24 2.71 3.83 4.69 5.57 6.44 7.31 8.17 9.04 9.90 11.84 12.83 13.83 14.82 15.82 17.81
22 90 Branch Weld Unreinforced Unit hrs 0.87 1.22 1.58 1.96 2.35 2.66 2.96 3.57 4.91 5.98 7.06 8.13 9.24 10.34 11.45 12.56 15.32 16.60 17.87 19.14 20.42 22.96
23 Angle Branch weld Unreinforced Unit hrs 1.07 1.50 1.93 2.36 2.78 3.17 3.54 4.30 5.97 7.31 8.66 10.00 11.39 12.79 14.18 15.58 18.64 20.19 21.74 23.28 24.84 27.94
24 Weld Weldolet Unit hrs 0.93 1.23 1.54 1.87 2.21 2.46 2.69 3.18 4.52 5.47 6.45 7.40 8.50 9.55 10.58 11.62 13.69
25 Weld Latrolet Unit hrs 1.10 1.53 1.94 2.40 2.84 3.20 3.53 4.20 6.07 7.46 8.87 10.26
26 Weld Elbolet Unit hrs 1.26 1.76 2.26 2.79 3.32 3.71 4.08 4.83 6.83 8.22
27 Socket Weld Unit hrs 0.21 0.26 0.32 0.50 0.64 0.72 0.78 0.93 1.23 1.50
84
H.2.21 Pipework Erection Sch80 Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch 80
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 3.73 3.91 4.55 5.08 5.54 7.01 7.62 8.56 10.97 12.70 15.06 17.45 19.05 21.41 23.80 26.19 30.94Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.42 0.42 0.45 0.49 0.52 0.55 0.58 0.65 0.78 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94
2A Erect Pipe (double random) hrs/metre 0.30 0.30 0.32 0.36 0.39 0.41 0.42 0.45 0.52 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43
1B Erect Pipe (single random & spooled ) hrs/foot 0.13 0.13 0.14 0.15 0.16 0.17 0.18 0.20 0.24 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.59
2B Erect Pipe (double random) hrs/foot 0.09 0.09 0.10 0.11 0.12 0.13 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43
3 Install Valves, steam traps, strainers and the likeUnit hrs 0.26 0.26 0.30 0.32 0.36 0.40 0.42 0.49 0.81 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24
4 Install Control Valve or similar Unit hrs 0.35 0.35 0.40 0.43 0.48 0.53 0.57 0.66 1.09 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31
5 Install Blank Flange Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
6 Install Spec Plate or similar Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
7 Make Flange Joint 150 # Unit hrs 0.17 0.17 0.17 0.17 0.19 0.19 0.19 0.36 0.42 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46
8 Make Flange Joint 300 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.46 0.49 0.55 0.81 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47
9 Make Flange Joint 600 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.48 0.52 0.62 1.01 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31
10 Make Flange Joint 900 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.57 0.62 0.71 1.23 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.58 0.65 0.78 1.43 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
12 Make Flange Joint 2500 # Unit hrs 0.17 0.20 0.24 0.27 0.54 0.61 0.68 0.85 1.66 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.10 0.10 0.13 0.19 0.26 0.30 0.32 0.39 0.50 0.58 0.82 0.93 1.09 1.24 1.40 1.94 2.29
14 Mitre Cut Unit hrs 0.10 0.13 0.17 0.20 0.23 0.29 0.34 0.45 0.59 0.73 1.05 1.22 1.39 1.56 1.74 2.39
15 Pulled Bend Unit hrs 0.19 0.19 0.23 0.31 0.42 0.60 0.78 1.14
16 Thread End Unit hrs 0.12 0.18 0.19 0.21 0.24 0.28 0.31 0.37
17 Make Screwed Joint Unit hrs 0.12 0.12 0.12 0.15 0.19 0.24 0.28 0.38
18 Butt Weld Unit hrs 0.51 0.66 0.88 1.12 1.38 1.53 1.66 2.02 2.88 3.51 4.81 6.32 7.20 9.14 11.50 15.15 20.41
19 Weld Neck Flange Weld Unit hrs 0.54 0.73 0.94 1.19 1.44 1.59 1.72 2.08 2.94 3.57 4.87 6.39 7.27 9.20 11.57 15.22 20.38
20 Slip On Flange Weld Unit hrs 0.41 0.50 0.64 0.86 1.07 1.20 1.30 1.50 2.08 2.46 3.28 4.26 4.83 6.08 7.63 9.91 13.53
21 Mitre Butt Weld Unit hrs 0.68 0.91 1.19 1.48 1.76 2.01 2.24 2.71 3.83 4.69 6.49 8.40 9.54 11.85 14.70 19.41 26.38
22 90 Branch Weld Unreinforced Unit hrs 0.87 1.22 1.58 1.96 2.35 2.66 2.96 3.57 4.91 6.01 8.48 10.53 11.97 14.59 17.73 23.78 32.10
23 Angle Branch weld Unreinforced Unit hrs 1.07 1.50 1.93 2.36 2.78 3.17 3.54 4.30 5.97 7.31 10.28 12.96 14.78 18.08 22.06 29.64 39.37
24 Weld Weldolet Unit hrs 0.93 1.23 1.54 1.87 2.21 2.46 2.69 3.18 4.52 5.47 7.61 9.95 11.44 14.50 18.27 24.36 32.74
25 Weld Latrolet Unit hrs 1.10 1.53 1.94 2.40 2.84 3.20 3.53 4.20 6.07 7.46 10.47 13.80
26 Weld Elbolet Unit hrs 1.26 1.76 2.26 2.79 3.32 3.71 4.08 4.83 6.83 8.22
27 Socket Weld Unit hrs 0.21 0.26 0.32 0.50 0.64 0.72 0.78 0.93 1.23 1.50
85
H.2.22 Pipework Erection Sch100 Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch 100
n.b - inches 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 15.06 18.24 21.41 23.80 26.19 29.36 32.51 38.89Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94
2A Erect Pipe (double random) hrs/metre 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43
1B Erect Pipe (single random & spooled ) hrs/foot 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.59
2B Erect Pipe (double random) hrs/foot 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43
3 Install Valves, steam traps, strainers and the likeUnit hrs 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24
4 Install Control Valve or similar Unit hrs 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31
5 Install Blank Flange Unit hrs 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
6 Install Spec Plate or similar Unit hrs 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
7 Make Flange Joint 150 # Unit hrs 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46
8 Make Flange Joint 300 # Unit hrs 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47
9 Make Flange Joint 600 # Unit hrs 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31
10 Make Flange Joint 900 # Unit hrs 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
12 Make Flange Joint 2500 # Unit hrs 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.70 0.82 0.93 1.09 1.56 1.75 1.94 2.29
14 Mitre Cut Unit hrs 0.88 1.05 1.22 1.39 1.95 2.17 2.39 3.00
15 Pulled Bend Unit hrs
16 Thread End Unit hrs
17 Make Screwed Joint Unit hrs
18 Butt Weld Unit hrs 4.07 5.47 7.14 9.25 12.45 15.77 18.76 25.50
19 Weld Neck Flange Weld Unit hrs 4.13 5.54 7.20 9.31 12.52 15.83 18.82 25.46
20 Slip On Flange Weld Unit hrs 2.82 3.74 4.81 6.20 8.21 10.38 12.29 16.95
21 Mitre Butt Weld Unit hrs 5.48 7.27 9.34 11.89 16.02 19.98 23.53 32.47
22 90 Branch Weld Unreinforced Unit hrs 7.09 9.15 11.48 14.32 19.60 23.96 27.90 38.19
23 Angle Branch weld Unreinforced Unit hrs 8.67 11.24 14.12 17.70 24.31 29.83 34.86 46.97
24 Weld Weldolet Unit hrs 6.46 8.67 11.24 14.71 20.03 25.34 30.14 40.88
25 Weld Latrolet Unit hrs 8.81 11.93 15.61
26 Weld Elbolet Unit hrs 9.69
27 Socket Weld Unit hrs 1.62
86
H.2.23 Pipework Erection Sch120 Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch 120
n.b - inches 4" 6" 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 100 150 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 11.10 12.70 18.24 21.41 2.54 27.76 30.94 34.93 38.10 46.02Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.65 0.78 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94
2A Erect Pipe (double random) hrs/metre 0.45 0.52 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43
1B Erect Pipe (single random & spooled ) hrs/foot 0.20 0.24 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.59
2B Erect Pipe (double random) hrs/foot 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43
3 Install Valves, steam traps, strainers and the likeUnit hrs 0.49 0.81 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24
4 Install Control Valve or similar Unit hrs 0.66 1.09 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31
5 Install Blank Flange Unit hrs 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
6 Install Spec Plate or similar Unit hrs 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
7 Make Flange Joint 150 # Unit hrs 0.36 0.42 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46
8 Make Flange Joint 300 # Unit hrs 0.55 0.81 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47
9 Make Flange Joint 600 # Unit hrs 0.62 1.01 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31
10 Make Flange Joint 900 # Unit hrs 0.71 1.23 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 0.78 1.43 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
12 Make Flange Joint 2500 # Unit hrs 0.85 1.66 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.39 0.60 0.70 0.82 0.93 1.36 1.56 1.75 1.94 2.29
14 Mitre Cut Unit hrs 0.45 0.71 0.88 1.05 1.22 1.74 1.95 2.17 2.39 3.00
15 Pulled Bend Unit hrs 1.14
16 Thread End Unit hrs 0.37
17 Make Screwed Joint Unit hrs 0.38
18 Butt Weld Unit hrs 2.23 3.33 4.63 6.18 8.12 11.08 14.24 17.08 20.20 29.32
19 Weld Neck Flange Weld Unit hrs 2.30 3.40 4.69 6.25 8.19 11.15 14.30 17.15 20.27 29.28
20 Slip On Flange Weld Unit hrs 1.66 2.38 3.21 4.23 5.48 7.37 9.40 11.25 13.24 19.51
21 Mitre Butt Weld Unit hrs 2.96 4.47 6.13 8.09 10.47 14.33 18.06 21.49 25.17 37.03
22 90 Branch Weld Unreinforced Unit hrs 3.82 5.83 7.75 9.96 12.61 17.52 21.65 25.46 29.55 42.75
23 Angle Branch weld Unreinforced Unit hrs 4.62 7.08 9.48 12.25 15.52 21.65 26.88 31.73 36.95 52.67
24 Weld Weldolet Unit hrs 3.54 5.33 7.36 9.79 12.79 17.85 22.89 27.45 32.45 46.99
25 Weld Latrolet Unit hrs 4.66 7.17 10.03 13.48 17.77
26 Weld Elbolet Unit hrs 5.42 8.06 11.13
27 Socket Weld Unit hrs 0.93 1.33 1.62
87
H.2.24 Pipework Erection Sch140 Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch 140
n.b - inches 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 20.62 2.54 28.58 31.75 36.50 39.67 44.45 52.37Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94
2A Erect Pipe (double random) hrs/metre 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43
1B Erect Pipe (single random & spooled ) hrs/foot 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.592B Erect Pipe (double random) hrs/foot 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43
3 Install Valves, steam traps, strainers and the likeUnit hrs 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24
4 Install Control Valve or similar Unit hrs 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31
5 Install Blank Flange Unit hrs 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
6 Install Spec Plate or similar Unit hrs 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
7 Make Flange Joint 150 # Unit hrs 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46
8 Make Flange Joint 300 # Unit hrs 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47
9 Make Flange Joint 600 # Unit hrs 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31
10 Make Flange Joint 900 # Unit hrs 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
12 Make Flange Joint 2500 # Unit hrs 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.70 0.82 1.17 1.36 1.56 1.75 1.94 2.29
14 Mitre Cut Unit hrs 0.88 1.05 1.52 1.74 1.95 2.17 2.39 3.00
15 Pulled Bend Unit hrs
16 Thread End Unit hrs
17 Make Screwed Joint Unit hrs
18 Butt Weld Unit hrs 5.23 7.03 9.73 12.67 16.62 19.71 23.09 33.13
19 Weld Neck Flange Weld Unit hrs 5.29 7.10 9.80 12.74 16.68 19.78 23.15 33.1020 Slip On Flange Weld Unit hrs 3.62 4.81 6.50 8.44 10.98 13.00 15.14 22.08
21 Mitre Butt Weld Unit hrs 6.82 9.07 12.63 16.16 20.78 24.50 28.47 41.59
22 90 Branch Weld Unreinforced Unit hrs 8.44 10.95 15.42 19.35 24.37 28.48 32.84 47.31
23 Angle Branch weld Unreinforced Unit hrs 10.34 13.47 18.99 23.93 30.30 35.53 41.14 58.37
24 Weld Weldolet Unit hrs 8.32 11.14 15.53 20.40 26.70 31.66 37.07 53.09
25 Weld Latrolet Unit hrs 11.34 15.35 21.57
26 Weld Elbolet Unit hrs 12.65
27 Socket Weld Unit hrs 1.62
88
H.2.25 Pipework Erection Sch160 Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch 160
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600
Work Operation W.T. - mm 4.75 5.54 6.35 7.14 8.71 9.53 11.10 13.49 18.24 23.01 28.58 33.32 35.71 40.46 43.64 49.99 59.51Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.42 0.42 0.45 0.49 0.52 0.55 0.58 0.65 0.78 0.88 1.01 1.10 1.23 1.33 1.46 1.56 1.94
2A Erect Pipe (double random) hrs/metre 0.30 0.30 0.32 0.36 0.39 0.41 0.42 0.45 0.52 0.58 0.65 0.71 0.78 0.84 0.91 0.97 1.43
1B Erect Pipe (single random & spooled ) hrs/foot 0.13 0.13 0.14 0.15 0.16 0.17 0.18 0.20 0.24 0.27 0.31 0.34 0.38 0.41 0.45 0.47 0.59
2B Erect Pipe (double random) hrs/foot 0.09 0.09 0.10 0.11 0.12 0.13 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.43
3 Install Valves, steam traps, strainers and the like Unit hrs 0.26 0.26 0.30 0.32 0.36 0.40 0.42 0.49 0.81 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24
4 Install Control Valve or similar Unit hrs 0.35 0.35 0.40 0.43 0.48 0.53 0.57 0.66 1.09 2.38 3.25 4.32 5.40 6.48 7.56 9.94 12.31
5 Install Blank Flange Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
6 Install Spec Plate or similar Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52
7 Make Flange Joint 150 # Unit hrs 0.17 0.17 0.17 0.17 0.19 0.19 0.19 0.36 0.42 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46
8 Make Flange Joint 300 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.46 0.49 0.55 0.81 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47
9 Make Flange Joint 600 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.48 0.52 0.62 1.01 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31
10 Make Flange Joint 900 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.57 0.62 0.71 1.23 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
11 Make Flange Joint 1500 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.58 0.65 0.78 1.43 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
12 Make Flange Joint 2500 # Unit hrs 0.17 0.20 0.24 0.27 0.54 0.61 0.68 0.85 1.66 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.10 0.10 0.13 0.19 0.26 0.30 0.32 0.47 0.60 0.70 1.03 1.17 1.36 1.56 1.75 1.94 2.29
14 Mitre Cut Unit hrs 0.10 0.13 0.17 0.20 0.23 0.29 0.34 0.54 0.71 0.88 1.32 1.52 1.74 1.95 2.17 2.39 3.00
15 Pulled Bend Unit hrs 0.19 0.19 0.23 0.31 0.42 0.60 0.78 1.14
16 Thread End Unit hrs 0.12 0.18 0.19 0.21 0.24 0.28 0.31 0.41
17 Make Screwed Joint Unit hrs 0.12 0.12 0.12 0.15 0.19 0.24 0.28 0.38
18 Butt Weld Unit hrs 0.51 0.66 0.88 1.12 1.38 1.53 1.83 2.58 3.79 5.23 8.42 12.07 14.80 17.80 22.68 26.70 34.83
19 Weld Neck Flange Weld Unit hrs 0.54 0.73 0.94 1.19 1.44 1.59 1.90 2.65 3.86 5.29 8.49 12.14 14.87 17.87 22.74 26.76 34.79
20 Slip On Flange Weld Unit hrs 0.41 0.50 0.64 0.86 1.07 1.20 1.43 1.90 2.70 3.62 5.71 8.09 9.87 11.77 14.96 17.52 23.22
21 Mitre Butt Weld Unit hrs 0.68 0.91 1.19 1.48 1.76 2.01 2.46 3.45 5.01 6.82 10.93 15.32 18.61 22.15 27.89 32.59 43.62
22 90 Branch Weld Unreinforced Unit hrs 0.87 1.22 1.58 1.96 2.35 2.66 3.18 4.54 6.37 8.44 13.39 18.12 21.79 25.73 31.86 36.96 49.34
23 Angle Branch weld Unreinforced Unit hrs 1.07 1.50 1.93 2.36 2.78 3.17 3.82 5.47 7.75 10.34 16.47 22.31 26.98 32.01 39.81 46.36 60.91
24 Weld Weldolet Unit hrs 0.93 1.23 1.54 1.87 2.21 2.46 3.01 4.18 6.08 8.32 13.52 19.22 23.80 28.60 36.39 42.84 55.80
25 Weld Latrolet Unit hrs 1.10 1.53 1.94 2.40 2.84 3.20 3.93 5.50 8.16 11.34 18.63 26.72
26 Weld Elbolet Unit hrs 1.26 1.76 2.26 2.79 3.32 3.71 4.60 6.38 9.26 12.65
27 Socket Weld Unit hrs 0.21 0.26 0.32 0.50 0.64 0.72 0.78 1.01 1.33 1.62
89
H.2.26 Pipework Erection SchXXS Pipework Erection Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule Sch XXS
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300
Work Operation W.T. - mm 7.47 7.82 9.09 10.16 11.07 14.02 15.24 17.12 21.95 22.23 25.40 25.40Erection Activites
1A Erect Pipe (single random & spooled ) hrs/metre 0.42 0.42 0.45 0.49 0.52 0.55 0.58 0.65 0.78 0.88 1.01 1.10
2A Erect Pipe (double random) hrs/metre 0.30 0.30 0.32 0.36 0.39 0.41 0.42 0.45 0.52 0.58 0.65 0.71
1B Erect Pipe (single random & spooled ) hrs/foot 0.13 0.13 0.14 0.15 0.16 0.17 0.18 0.20 0.24 0.27 0.31 0.342B Erect Pipe (double random) hrs/foot 0.09 0.09 0.10 0.11 0.12 0.13 0.13 0.14 0.16 0.18 0.20 0.22
3 Install Valves, steam traps, strainers and the likeUnit hrs 0.26 0.26 0.30 0.32 0.36 0.40 0.42 0.49 0.81 1.79 2.43 3.24
4 Install Control Valve or similar Unit hrs 0.35 0.35 0.40 0.43 0.48 0.53 0.57 0.66 1.09 2.38 3.25 4.32
5 Install Blank Flange Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.326 Install Spec Plate or similar Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32
7 Make Flange Joint 150 # Unit hrs 0.17 0.17 0.17 0.17 0.19 0.19 0.19 0.36 0.42 0.49 0.94 1.01
8 Make Flange Joint 300 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.46 0.49 0.55 0.81 0.94 1.46 1.66
9 Make Flange Joint 600 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.48 0.52 0.62 1.01 1.20 1.85 2.5010 Make Flange Joint 900 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.57 0.62 0.71 1.23 1.68 2.14 2.59
11 Make Flange Joint 1500 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.58 0.65 0.78 1.43 1.87 2.31 2.75
12 Make Flange Joint 2500 # Unit hrs 0.17 0.20 0.24 0.27 0.54 0.61 0.68 0.85 1.66 2.08 2.50 2.92
In-Field Fabrication Activities - Material Factors only apply to the following norms13 Square Cut Unit hrs 0.10 0.10 0.13 0.19 0.26 0.33 0.38 0.46 0.60 0.70 0.82 0.93
14 Mitre Cut Unit hrs 0.10 0.13 0.17 0.20 0.23 0.34 0.41 0.54 0.71 0.88 1.05 1.22
15 Pulled Bend Unit hrs 0.19 0.19 0.23 0.31 0.42 0.60 0.78 1.14
16 Thread End Unit hrs 0.12 0.18 0.19 0.21 0.24 0.30 0.34 0.4017 Make Screwed Joint Unit hrs 0.12 0.12 0.12 0.15 0.19 0.24 0.28 0.38
18 Butt Weld Unit hrs 0.51 0.66 0.88 1.25 1.53 1.95 2.12 2.94 4.28 5.23 7.03 8.12
19 Weld Neck Flange Weld Unit hrs 0.54 0.73 0.94 1.31 1.59 2.02 2.18 3.00 4.34 5.29 7.10 8.19
20 Slip On Flange Weld Unit hrs 0.41 0.50 0.64 0.95 1.18 1.50 1.63 2.16 3.05 3.62 4.81 5.4821 Mitre Butt Weld Unit hrs 0.68 0.91 1.19 1.63 1.95 2.57 2.86 3.87 5.57 6.82 9.07 10.47
22 90 Branch Weld Unreinforced Unit hrs 0.87 1.22 1.58 2.12 2.54 3.39 3.77 4.96 6.94 8.44 10.95 12.61
23 Angle Branch weld Unreinforced Unit hrs 1.07 1.50 1.93 2.56 3.02 4.06 4.53 6.00 8.46 10.34 13.47 15.52
24 Weld Weldolet Unit hrs 0.93 1.23 1.54 2.11 2.49 3.31 3.64 4.85 6.87 8.32 11.14 12.7925 Weld Latrolet Unit hrs 1.10 1.53 1.94 2.69 3.19 4.21 4.64 6.25 9.21 11.34 15.35 17.77
26 Weld Elbolet Unit hrs 1.26 1.76 2.26 3.17 3.76 4.93 5.41 7.35 10.53 12.65
27 Socket Weld Unit hrs 0.21 0.26 0.32 0.50 0.64 0.78 0.85 1.01 1.33 1.62
90
H.2.27 Steam Tracing n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300
Work Operation W.T. - mm 2.76 2.87 3.37 3.68 3.91 5.15 5.48 6.02 7.11 8.17 9.27 9.52Erect carbon steel tubing including S/S banding to parent pipe at 500mm centres
hrs/metre 0.38 0.38 0.41
Erect copper tubing including S/S banding to parent pipe at 500mm centres
hrs/metre 0.44 0.44 0.47
Erect carbon steel tubing including S/S banding to parent pipe at 18 inch centres
hrs/foot 0.12 0.12 0.12
Erect copper tubing including S/S banding to parent pipe at 18 inch centres
hrs/foot 0.13 0.13 0.14
Form bend in carbon steel tube to radius of parent pipe
Unit hrs 0.18 0.20 0.25
Form bend in copper tube to radius of parent pipe Unit hrs 0.30 0.33 0.41Make screwed joint to brass fitting Unit hrs 0.16 0.16 0.16
On the following items the above sizes refer to the parent pipeCoil 6mm copper tubing at 75 mm centres along length of parent pipe exceeding 3 meters in length
hrs/metre 0.40 0.40 0.40 0.40 0.40 0.78 0.78 0.78
Coil 8mm copper tubing at 75 mm centres along length of parent pipe exceeding 3 meters in length
hrs/metre 0.49 0.49 0.49 0.49 0.49 0.98 0.98 0.98
Coil 10mm copper tubing at 75 mm centres along length of parent pipe exceeding 3 meters in length
hrs/metre 0.59 0.59 0.59 0.59 0.59 1.19 1.19 1.19 1.78 2.36 2.94 3.52
Coil 6mm copper tubing along length of valve or at 75mm centres along parent pipe not exceeding 3 metres in length
hrs/metre 0.49 0.49 0.49 0.49 0.49 0.97 0.97 0.97
Coil 8mm copper tubing along length of valve or at 75mm centres along parent pipe not exceeding 3 metres in length
hrs/metre 0.61 0.61 0.61 0.61 0.61 1.22 1.22 1.22
Coil 10mm copper tubing along length of valve or at 75mm centres along parent pipe not exceeding 3 metres in length
hrs/metre 0.74 0.74 0.74 0.74 0.74 1.48 1.48 1.48 2.22 2.95 3.67 4.40
Coil 1/4 inch copper tubing at 3 inch centres along length of parent pipe exceeding 10 feet in length
hrs/foot 0.12 0.12 0.12 0.12 0.12 0.24 0.24 0.24
Coil 3/8 inch copper tubing at 3 inch centres along length of parent pipe exceeding 10 feet in length
hrs/foot 0.15 0.15 0.15 0.15 0.15 0.30 0.30 0.30
Coil 1/2 inch copper tubing at 3 inch centres along length of parent pipe exceeding 10 feet in length
hrs/foot 0.18 0.18 0.18 0.18 0.18 0.36 0.36 0.36 0.54 0.72 0.90 1.07
Coil 1/4 inch copper tubing along length of valve or at 3 inch centres along parent pipe not exceeding 10 feets in length
hrs/foot 0.15 0.15 0.15 0.15 0.15 0.30 0.30 0.30
Coil 3/8 inch copper tubing along length of valve or at 3 inch centres along parent pipe not exceeding 10 feets in length
hrs/foot 0.23 0.23 0.23 0.23 0.23 0.45 0.45 0.45 0.68 0.90 1.12 1.34
Coil 1/2 inch copper tubing along length of valve or at 3 inch centres along parent pipe not exceeding 10 feets in length
hrs/foot 0.30 0.30 0.30 0.30 0.30 0.60 0.60 0.60 0.90 1.20 1.49 1.79
Coil 1/4 inch stainless steel tubing along length of valve or at 3 inch centres along parent pipe not exceeding 10 feets in length
hrs/foot 0.16 0.16 0.16 0.16 0.16 0.33 0.33 0.33
Coil 3/8 inch stainless steel tubing along length of valve or at 3 inch centres along parent pipe not exceeding 10 feets in length
hrs/foot 0.25 0.25 0.25 0.25 0.25 0.50 0.50 0.50 0.74 0.99 1.23 1.48
91
H.2.28 Hydrostatic and Pneumatic testing Hydrostatic and Pneumatic Testing - All materials, Schedules and Classification Material All Materials
Standard Norms Location Workshop and Insitu Onsite
Pipe Schedule Al Schedulesn.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36" 42" 48"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 650 700 750 800 900 1100 1200
Work Operation W.T. - mm 2.76 2.87 3.37 3.68 3.91 5.15 5.48 6.02 7.11 8.17 9.27 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52
Pressure test in workshop hrs/metre 0.03 0.03 0.03 0.05 0.05 0.06 0.10 0.10 0.15 0.20 0.25 0.30 0.39 0.39 0.44 0.54 0.59 0.63 0.68 0.72 0.77 0.88 0.88 0.88
Pressure test insitu onsite hrs/metre 0.03 0.03 0.03 0.07 0.07 0.08 0.13 0.13 0.20 0.26 0.33 0.39 0.52 0.52 0.59 0.66 0.79 0.85 0.91 0.96 1.04 1.18 1.18 1.18
Pressure test in workshop hrs/foot 0.009 0.009 0.009 0.015 0.015 0.018 0.030 0.030 0.046 0.061 0.076 0.091 0.119 0.119 0.134 0.165 0.180 0.193 0.206 0.220 0.236 0.268 0.268 0.268
Pressure test insitu onsite hrs/foot 0.009 0.009 0.009 0.021 0.021 0.024 0.040 0.040 0.061 0.079 0.101 0.119 0.159 0.159 0.180 0.201 0.241 0.259 0.276 0.294 0.316 0.359 0.359 0.359
92
H.2.29 Pipework Removal
Remove Pipework Material Carbon Steel
Standard Norms Location Ground level
Pipe Schedule All Schedules
n.b - inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 26" 28" 30" 32" 36" 42" 48"n.b - mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 650 700 750 800 900 1100 1200
Work Operation W.T. - mm 2.76 2.87 3.37 3.68 3.91 5.15 5.48 6.02 7.11 8.17 9.27 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.521A Remove Pipe hrs/metre 0.20 0.20 0.22 0.23 0.24 0.27 0.28 0.31 0.37 0.41 0.48 0.52 0.58 0.63 0.69 0.73 0.92 0.94 0.96 0.98 1.00 1.04 1.10 1.16
1B Remove Pipe hrs/foot 0.062 0.062 0.066 0.070 0.075 0.081 0.085 0.093 0.112 0.126 0.145 0.160 0.178 0.193 0.211 0.224 0.280 0.29 0.29 0.299 0.30 0.317 0.336 0.355
2 Remove Valve Unit hrs 0.18 0.18 0.21 0.23 0.26 0.28 0.30 0.35 0.58 1.26 1.73 2.30 2.88 3.44 4.02 5.28 6.54 6.96 7.38 7.81 8.65 10.33 12.85 15.37
3 Remove Blank Flange Unit hrs 0.11 0.11 0.11 0.14 0.14 0.16 0.16 0.16 0.20 0.22 0.25 0.28 0.31 0.33 0.36 0.39 0.44 0.46 0.48 0.50 0.51 0.55 0.61 0.66
4 Remove Spec Plate or Similar Unit hrs 0.11 0.11 0.11 0.14 0.14 0.16 0.16 0.16 0.20 0.22 0.25 0.28 0.31 0.33 0.36 0.39 0.44 0.46 0.48 0.50 0.51 0.55 0.61 0.665 Break Flange Joint 150 # Unit hrs 0.14 0.14 0.14 0.14 0.16 0.16 0.16 0.31 0.36 0.41 0.80 0.86 0.94 1.26 1.46 1.85 2.09 2.38 2.67 2.95 3.27 3.91 4.88 5.95
6 Break Flange Joint 300 # Unit hrs 0.14 0.16 0.20 0.22 0.36 0.39 0.41 0.47 0.69 0.80 1.24 1.41 1.85 2.07 2.51 2.73 2.95 3.28 3.61 3.94 4.27 4.93
7 Break Flange Joint 600 # Unit hrs 0.14 0.16 0.20 0.22 0.36 0.40 0.44 0.52 0.86 1.02 1.57 2.12 2.35 2.56 2.79 3.34 3.67 3.89 4.10 4.32 4.45 4.71
8 Break Flange Joint 900 # Unit hrs 0.14 0.16 0.20 0.22 0.44 0.48 0.52 0.61 1.05 1.26 1.82 2.37 2.67 2.97 3.28 3.58 4.19
9 Break Flange Joint 1500 # Unit hrs 0.14 0.16 0.20 0.22 0.44 0.50 0.55 0.66 1.21 1.49 1.76 2.31 2.70 3.09 3.47 3.86 4.41
10 Break Screwed Joint Unit hrs 0.10 0.10 0.10 0.12 0.16 0.19 0.22 0.31
11 Install Valve Unit hrs 0.26 0.26 0.30 0.32 0.36 0.40 0.42 0.49 0.81 1.79 2.43 3.24 4.05 4.86 5.67 7.45 9.24 9.83 10.42 11.02 12.20 14.58 18.14 21.71
12 Install Blank Flange Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65 0.71 0.7813 Install Spec Plate or similar Unit hrs 0.13 0.13 0.13 0.17 0.17 0.18 0.19 0.19 0.23 0.26 0.30 0.32 0.36 0.39 0.42 0.45 0.52 0.54 0.56 0.58 0.60 0.65 0.71 0.78
14 Make Flange Joint 150 # Unit hrs 0.17 0.17 0.17 0.17 0.19 0.19 0.19 0.36 0.42 0.49 0.94 1.01 1.10 1.49 1.72 2.17 2.46 2.80 3.13 3.47 3.85 4.60 5.74 7.00
15 Make Flange Joint 300 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.46 0.49 0.55 0.81 0.94 1.46 1.66 2.17 2.43 2.95 3.21 3.47 3.86 4.25 4.64 5.03 5.80
16 Make Flange Joint 600 # Unit hrs 0.17 0.19 0.23 0.26 0.42 0.48 0.52 0.62 1.01 1.20 1.85 2.50 2.76 3.02 3.28 3.92 4.31 4.57 4.83 5.09 5.24 5.54
17 Make Flange Joint 900 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.57 0.62 0.71 1.23 1.68 2.14 2.59 3.05 3.50 3.86 4.21 4.92
18 Make Flange Joint 1500 # Unit hrs 0.17 0.19 0.23 0.26 0.52 0.58 0.65 0.78 1.43 1.87 2.31 2.75 3.19 3.63 4.08 4.54 5.18
19 Make Flange Joint 2500 # Unit hrs 0.17 0.20 0.24 0.27 0.54 0.61 0.68 0.85 1.66 2.08 2.50 2.92
20 Make Screwed Joint Unit hrs 0.12 0.12 0.12 0.15 0.19 0.24 0.28 0.38
Material Factors only apply to the following norms21 Square Cut (Upto 15mm thick) Unit hrs 0.06 0.10 0.12 0.18 0.24 0.28 0.31 0.37 0.47 0.55 0.65 0.73 0.86 0.98 1.10 1.22 1.44 1.56 1.69 1.81 1.93 2.18 2.54 2.91
22 Square Cut (>15mm up to 25mm thick) Unit hrs 0.37 0.44 0.56 0.66 0.78 0.88 1.03 1.18 1.32 1.47 1.73 1.87 2.02 2.17 2.32 2.61 3.05 3.50
23 Square Cut (> 25mm thick) Unit hrs 0.97 1.10 1.29 1.47 1.65 1.84 2.16 2.35 2.53 2.71 2.90 3.26 3.81 4.37
24 Square Cold Cut (Upto 15mm thk) Unit hrs 0.12 0.19 0.24 0.37 0.49 0.56 0.61 0.73 0.94 1.10 1.29 1.47 1.71 1.96 2.20 2.45 2.88 3.13 3.37 3.62 3.86 4.35 5.09 5.82
25 Square Cold Cut (>15mm up to 25mm thk) Unit hrs 0.73 0.88 1.13 1.32 1.55 1.77 2.05 2.35 2.64 2.94 3.45 3.75 4.04 4.34 4.63 5.22 6.11 6.99
26 Square Cold Cut (>25mm thk) Unit hrs 1.94 2.20 2.57 2.94 3.30 3.67 4.32 4.69 5.06 5.43 5.79 6.53 7.63 8.73
93
H.2.30 Pipework Support Fabrication Pipe Support Fabrication Material Carbon Steel
Standard Norms Location Site Workshop
Pipe Schedule Standard Wall Thickness (STD WT)
Pipe Attachments Size mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600Inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24"
Fabricate including profile cut 90deg tubular support incl baseplate Unit hrs 0.58 0.65 0.76 0.94 1.12 1.30 1.48 1.76 2.20 2.59 3.06 3.85 4.68 5.04 5.47 5.83 6.98
Fabricate including profile cut 90deg tubular to elbow incl baseplate Unit hrs 0.67 0.83 0.97 1.19 1.33 1.62 1.91 2.23 2.81 3.24 4.00 4.93 5.83 6.52 7.06 7.34 8.89
Carbon Steel Pipe SupportsWeight Band
ne 5kg> 5 kg ne
10kg>10kg ne
15kg>15kg ne
20kg>20kg ne
25kg>25kg ne
50kg>50kg
Fabrication of Slippers, Guides, Anchors, Brackets and the like Kg hrs 0.16 0.12 0.11 0.10 0.09 0.07 0.05
Carbon Steel Pipe SupportsWeight Band
ne 11 lb> 11 lb ne
22 lb>22 lb ne
33 lb>33 lb ne
4 4lb>44 lb ne
55 lb>55 lb ne
110 lb>110 lb
Fabrication of Slippers, Guides, Anchors, Brackets and the like lb hrs 0.073 0.055 0.048 0.045 0.041 0.033 0.022
Above rates apply to STD WT pipe attachments. Star Rates for pipe attachments of other thicknesses should be prorated from the STD WT norm s
94
H.2.31 Pipework Support Erection Pipe Support Erection Material Carbon Steel
Standard Norms Location All Locations
Pipe Schedule N/A
Work Operation Size mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 750 900 1100 1200Inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" 42" 48"
Erect U-bolt or similar including drilling holes in steel section Unit hrs 0.52 0.52 0.52 0.52 0.52 0.55 0.55 0.55 0.55 0.58 0.58 0.58 0.58 0.58 0.61 0.61 0.82 0.82 0.99 1.36 1.36
Work Operation Rod Length Up to
500mm long
500 - 1000mm
long
Up to 20 inches long
20 to 40 inches long
Erection of 13mm drop eye hanger rod including drilling holes in steel section Unit hrs 0.49 0.54 0.50 0.55
Erection of 16 mm drop eye hanger rod including drilling holes in steel section Unit hrs 0.53 0.58 0.54 0.59
Erection of 20mm drop eye hanger rod including drilling holes in steel section Unit hrs 0.59 0.65 0.60 0.66
Carbon Steel Pipe supports Weight Band
ne 5kg> 5 kg ne
10kg>10kg ne
15kg>15kg ne
20kg>20kg ne
25kg>25kg ne
50kg>50kg
Erection of Slippers, Guides, Anchors, Brackets and the like Kg hrs 0.10 0.09 0.07 0.06 0.06 0.05 0.04
Carbon Steel Pipe supportsWeight Band
ne 11 lb> 11 lb ne
22 lb>22 lb ne
33 lb>33 lb ne
4 4lb>44 lb ne
55 lb>55 lb ne
110 lb>110 lb
Erection of Slippers, Guides, Anchors, Brackets and the like lb hrs 0.045 0.042 0.033 0.028 0.025 0.023 0.019
Pipe Attachments Size mm 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 750 900 1100 1200
Inches 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" 42" 48"
Tubular support welded to straight pipe Unit hrs 0.22 0.34 0.45 0.60 0.75 0.82 0.90 1.05 1.31 1.57 1.83 2.09 2.36 2.54 2.81 3.07 3.81
Tubular support welded to pipe bend/elbow Unit hrs 0.37 0.56 0.75 0.94 1.12 1.22 1.31 1.50 1.91 2.32 2.73 3.14 3.55 3.96 4.38 4.79 5.76
Fabricate and Weld Reinforcing Pad (Header size) Unit hrs 1.22 1.42 1.62 1.90 2.80 3.44 4.38 5.50 6.42 7.36 8.29 9.40 11.06
95
H.3 Pipe size conversion tables ANSI Schedules - Wall Thicknesses
Nominal OutsidePipe Size Diameter
mm15 21.34 1.65 2.11 - - - 2.77 2.77 2.77 - 3.73 3.73 3.73 - - - 4.75 7.47
20 26.67 1.65 2.11 2.11 - - 2.87 2.87 2.87 - 3.91 3.91 3.91 - - - 5.54 7.82
25 33.4 1.65 2.77 2.77 - - 3.38 3.38 3.38 - 4.55 4.55 4.55 - - - 6.35 9.09
40 48.26 1.65 2.77 2.77 - - 3.68 3.68 3.68 - 5.08 5.08 5.08 - - - 7.14 10.16
50 60.32 1.65 2.77 2.77 - - 3.91 3.91 3.91 - 5.54 5.54 5.54 - - - 8.71 11.07
65 73.02 2.11 3.05 3.05 - - 5.16 5.16 5.16 - 7.01 7.01 7.01 - - - 9.52 14.02
80 88.9 2.11 3.05 3.05 - - 5.49 5.49 5.49 - 7.62 7.62 7.62 - - - 11.13 15.24
100 114.3 2.11 3.05 3.05 - - 6.02 6.02 6.02 - 8.56 8.56 8.56 - 11.13 - 13.49 17.12
150 168.28 2.77 3.4 - - - 7.11 7.11 7.11 - 10.97 10.97 10.97 - 14.27 - 18.24 21.95
200 219.08 2.77 3.76 - 6.35 7.04 8.18 8.18 8.18 10.31 12.7 12.7 12.7 15.06 18.26 20.62 23.01 22.22
250 273.05 3.4 4.19 - 6.35 7.8 9.27 9.27 9.27 12.7 12.7 12.7 15.06 18.26 21.44 25.4 28.58 25.4
300 323.85 3.96 4.57 - 6.35 8.38 9.52 9.52 10.31 14.27 12.7 12.7 17.48 21.44 25.4 28.58 33.32 25.4
350 355.6 3.96 4.78 6.35 7.92> 9.52 - 9.52 11.13 15.06 12.7 19.05 23.83 27.79 31.75 35.71 -
400 406.4 4.19 4.78 6.35 7.92 9.52 - 9.52 12.7 16.66 12.7 21.44 26.19 30.96 36.52 40.46 -
450 457.2 4.19 4.78 6.35 7.92 11.12 - 9.52 14.27 19.05 12.7 23.82 29.36 34.92 39.67 45.24 -
500 508 4.78 5.54 6.35 9.52 12.7 - 9.52 15.06 20.62 12.7 26.19 32.54 38.1 44.45 49.99 -
600 609.4 5.54 6.35 6.35 9.52 14.27 - 9.52 17.48 24.61 12.7 30.93 38.89 46.02 52.37 59.51 -
650 660.4 - - - 9.52 - - 12.7 -
700 711.2 - 12.7 15.88 9.52 - - 12.7 -
750 762 6.35 7.92 7.92 12.7 15.88 - 9.52 - - 12.7 - - - - - -
800 812.8 9.52 17.48 - 12.7 -
900 914.4 - - 7.92 12.7 15.88 - 9.52 19.05 - 12.7 - - - - - -
1100 1066.8 - - - - - - 9.52 - - 12.7 - - - - - -
1200 1219.2 - - - - - - 9.52 - - 12.7 - - - - - -
XXSSch 100 Sch 120 Sch 140 Sch 160Sch 60 Sch 80S XS Sch 80Sch 30 Sch 40S STD Sch 40Sch 5S Sch 10S Sch 10 Sch 20
ANSI to DIN Wall Thickness Convertion Table
DIN
Wall thicknesses
in mm
2.00 1.65
2.60 2.11
2.90 2.77 2.87
3.20 3.05
3.60 3.38 3.40 3.56
4.00 3.68 3.76 3.91 3.96
4.50 4.19 4.57 4.78 4.85
5.00 5.08
5.60 5.16 5.49 5.54 5.74
6.30 6.02 6.35 6.55
7.10 7.01 7.11
8.00 7.62 7.80 7.92 8.08
8.80 8.18 8.38 8.56
10.00 9.27 9.52 10.31
11.00 10.97 11.12 11.13
11.50
12.70 12.70
14.20 14.27
16.00 15.06
17.50 16.66 17.48
20.62 20.62 19.05 21.44
25.00 23.82 24.61
26.19 26.19 28.58 30.93
ANSI
Wall thicknesses in mm
96
J.1 Electrical & Instrumentation Norms
J.2.1 Conduit Installation
Unit Hrs20mm surface run 0.598 25mm surface run 0.728 32mm surface run 0.832 20mm surface run 0.520 25mm surface run 0.650 32mm surface run 0.780
surface run 0.390 In screed or slab 0.325 surface run 0.455 In screed or slab 0.390 surface run 0.520 In screed or slab 0.455
Conduit (Install)
Heavy gauge steel, Black or galvanised; inc. cutting, fittings & fixingsSteel in chase, screed or slab
PVC; inc. cutting, fittings & fixings
20mm
25mm
32mm
97
J.2.2 Trunking Installation
Unit HrsSteel trunking, inc all fixings and covers 38mm x 38mm surface run 0.368
50mm x 50mm surface run 0.36875mm x 50mm surface run 0.45575mm x 75mm surface run 0.455100mm x 50mm surface run 0.498100mm x 75mm surface run 0.498100mm x 100mm surface run 0.606150mm x 50mm surface run 0.715150mm x 75mm surface run 0.715150mm x 100mm surface run 0.758150mm x 150mm surface run 0.801225mm x 100mm surface run 0.866225mm x 150mm surface run 0.866300mm x 150mm surface run 1.516
4 way Junction 0.368Angles 0.173con. Sleeves 0.195End caps 0.065Tees 0.2814 way Junction 0.368Angles 0.173con. Sleeves 0.195End caps 0.065Tees 0.2814 way Junction 0.368Angles 0.173con. Sleeves 0.195End caps 0.065Tees 0.2814 way Junction 0.368Angles 0.173con. Sleeves 0.195End caps 0.065Tees 0.2814 way Junction 0.455Angles 0.216con. Sleeves 0.238End caps 0.065Tees 0.3254 way Junction 0.455Angles 0.216con. Sleeves 0.238End caps 0.065Tees 0.3254 way Junction 0.455Angles 0.216con. Sleeves 0.238End caps 0.086Tees 0.325
Trunking (Install)
Steel trunking, fittings
100mm x 100mm
Steel trunking
38mm x 38mm
50mm x 50mm
75mm x 50mm
75mm x 75mm
100mm x 50mm
100mm x 75mm
98
Unit Hrs4 way Junction 0.455Angles 0.303con. Sleeves 0.238End caps 0.086Tees 0.3254 way Junction 0.541Angles 0.303con. Sleeves 0.281End caps 0.086Tees 0.4114 way Junction 0.541Angles 0.303con. Sleeves 0.281End caps 0.130Tees 0.4114 way Junction 0.541Angles 0.303con. Sleeves 0.277End caps 0.130Tees 0.4114 way Junction 0.650Angles 0.346con. Sleeves 0.433End caps 0.173Tees 0.5204 way Junction 0.736Angles 0.390con. Sleeves 0.433End caps 0.173Tees 0.5854 way Junction 0.866Angles 0.520con. Sleeves 0.433End caps 0.216Tees 0.650
All sizes Remove & replace lids 0.130
Steel trunking, fittings
Trunking (Install)
150mm x 50mm
150mm x 75mm
150mm x 100mm
150mm x 150mm
300mm x 150mm
225mm x 150mm
225mm x 100mm
99
J.2.3 Tray Installation
Unit Hrs50mm surface run 0.28175mm surface run 0.281100mm surface run 0.411
Tees 0.390Risers 0.260Bends 0.260Connectors 0.195Crossovers 0.455Tees 0.390Risers 0.260Bends 0.260Connectors 0.195Crossovers 0.455Tees 0.411Risers 0.281Bends 0.281Connectors 0.195Crossovers 0.476
150mm surface run 0.411200mm surface run 0.498225mm surface run 0.498250mm surface run 0.498300mm surface run 0.650
Tees 0.411Risers 0.281Bends 0.281Connectors 0.195Crossovers 0.476Tees 0.520Risers 0.368Bends 0.368Connectors 0.195Crossovers 0.628Tees 0.520Risers 0.368Bends 0.368Connectors 0.195Crossovers 0.628Tees 0.650Risers 0.368Bends 0.368Connectors 0.195Crossovers 0.628Tees 0.650Risers 0.411Bends 0.411Connectors 0.195Crossovers 0.758
Tray (Install)
150mm
200mm
225mm
250mm
300mm
50mm
75mm
100mm
Light gauge tray
Light gauge tray fittings
Medium gauge tray
Medium gauge tray fittings
100
Unit Hrs375mm surface run 0.693450mm surface run 0.736525mm surface run 0.866600mm surface run 1.040750mm surface run 1.126900mm surface run 1.278
Tees 0.975Risers 0.411Bends 0.411Connectors 0.195Crossovers 0.758Tees 0.996Risers 0.693Bends 0.693Connectors 0.195Crossovers 1.256Tees 1.300Risers 0.693Bends 0.693Connectors 0.195Crossovers 1.256Tees 1.430Risers 0.866Bends 0.866Connectors 0.195Crossovers 1.451Tees 1.516Risers 1.040Bends 1.040Connectors 0.195Crossovers 1.451Tees 1.906Risers 1.256Bends 1.256Connectors 0.195Crossovers 1.668
150 to 50mm Reducers 0.195300 to 200mm Reducers 0.303600 to 375mm Reducers 0.476900 to 750mm Reducers 0.758
Tray (Install)
375mm
450mm
525mm
600mm
750mm
900mm
Heavy gauge tray
Heavy gauge tray fittings
101
J.2.4 Rack installation
Unit Hrs150mm surface run 0.866200mm surface run 0.866300mm surface run 1.126450mm surface run 1.408600mm surface run 1.690900mm surface run 2.058
4 way Junction 0.650Tees 0.476Risers 0.433Internal bends 0.346Couplers 0.346End Connectors 0.346External bends 0.3464 way Junction 0.650Tees 0.476Risers 0.650Internal bends 0.346Couplers 0.346End Connectors 0.346External bends 0.3464 way Junction 0.866Tees 0.736Risers 0.866Internal bends 0.433Couplers 0.346End Connectors 0.346External bends 0.4334 way Junction 1.516Tees 1.256Risers 1.083Internal bends 1.083Couplers 0.346End Connectors 0.346External bends 1.0834 way Junction 1.776Tees 1.516Risers 1.343Internal bends 1.300Couplers 0.346End Connectors 0.346External bends 1.3004 way Junction 1.950Tees 1.733Risers 1.516Internal bends 1.560Couplers 0.346End Connectors 0.346External bends 1.560
Rack (Install)
Heavy Duty ladder rack
Heavy Duty ladder rack fittings
150mm
200mm
300mm
450mm
600mm
900mm
102
J.2.5 Supporting Steelwork Fabricate & Install)
Unit HrsMild Steel, flats, angles, sections
Not exceeding 2kg 0.546Exc. 2kg but N.E 5kg 0.546Exc. 5kg but N.E 15kg 0.507Exc. 15kg but N.E 25kg 0.507Exc. 25kg but N.E 50kg 0.442Exceeding 50kg 0.442
Unistrut Not exceeding 2kg 0.520Exc. 2kg but N.E 5kg 0.520Exc. 5kg but N.E 15kg 0.481Exc. 15kg but N.E 25kg 0.481Exc. 25kg but N.E 50kg 0.429Exceeding 50kg 0.429
Supporting steel (Fabricate & Install)
J.2.6 Supporting Steelwork (Install Only)
Unit HrsThreaded rod
6mm Diameter (M6) 0.325 8mm Diameter (M8) 0.351 10mm Diameter (M10) 0.377 12mm Diameter (M12) 0.416 16mm Diameter (M16) 0.468
Supporting steel (Install)
103
J.2.7 Cable Installation Cables (Install)
1.5mm 2.5mm 4mm 6mm 10mm 16mm 25mm 35mm 50mm 70mm 95mm 120mm 150mm 185mm 240mm 300mm 400mm 500mm 630mm 800mm 1000mmSingle core 0.169 0.169 0.211 0.211 0.233 0.233 0.233 0.233 0.339 0.339 0.382 0.460 0.550 0.660 0.700Two core 0.043 0.043 0.065 0.065 0.108 0.108 0.173 0.173 0.216 0.216 0.238 0.238 0.238 0.238 0.346 0.346 0.390Three core 0.065 0.065 0.086 0.086 0.130 0.130 0.195 0.195 0.238 0.238 0.260 0.260 0.260 0.260 0.390 0.390 0.433Four core 0.086 0.086 0.108 0.108 0.151 0.151 0.216 0.216 0.260 0.260 0.281 0.281 0.281 0.281 0.433 0.433 0.476Single core 0.392 0.413 0.445 0.456 0.477 0.499 0.520 0.573 0.636 0.722 0.817 0.817 0.974 1.234 1.299Two core 0.129 0.129 0.205 0.238 0.260 0.314 0.400 0.422 0.454 0.465 0.487 0.509 0.530 0.584 0.649 0.736 0.833Three core 0.129 0.129 0.205 0.238 0.260 0.314 0.444 0.465 0.498 0.519 0.553 0.584 0.649 0.682 0.736 0.823 0.931Four core 0.129 0.129 0.205 0.238 0.260 0.346 0.476 0.487 0.530 0.541 0.584 0.617 0.671 0.714 0.844 0.909 1.018Single core 1.278 1.365 1.430 1.451 1.495 1.560 1.668 2.231 2.383 2.513 3.250 4.560 4.960 6.000 8.000Two core 0.628 0.628 0.628 0.650 0.845 0.996 1.278 1.365 1.430 1.451 1.495 1.560 1.668 2.231 2.383 2.513 3.250Three core 0.671 0.671 0.671 0.693 0.931 1.083 1.365 1.495 1.560 1.625 1.668 1.776 1.885 2.340 2.600 2.816 3.683Four core 0.736 0.736 0.736 0.758 1.061 1.213 1.495 1.690 1.755 1.885 1.928 2.101 2.210 2.426 3.120 3.250 3.900Single core 3.336 3.336 3.336 3.640 3.640 4.203 4.203 6.175 7.583 8.125 8.666Two core 3.336 3.336 3.336 3.640 3.640 4.203 4.203 6.175 7.583 8.125 8.666Three core 3.553 3.553 3.553 3.813 3.813 4.333 4.333 6.283 7.908 8.450 8.987Four core 3.770 3.770 3.770 4.051 4.051 4.550 4.550 6.608 8.233 8.775 9.316Single core 3.120 3.120 3.120 3.380 3.380 3.900 3.900 5.741 6.175 6.608 7.041Two core 3.120 3.120 3.120 3.380 3.380 3.900 3.900 5.741 6.175 6.608 7.041Three core 3.228 3.228 3.228 3.488 3.488 4.008 4.008 6.309 6.500 6.933 7.366Four core 3.336 3.336 3.336 3.618 3.618 4.116 4.116 6.175 6.825 7.258 7.691Single core 3.770 3.770 3.770 4.073 4.073 4.636 4.636 6.608 9.100 9.533 9.966Two core 3.770 3.770 3.770 4.073 4.073 4.636 4.636 6.608 9.100 9.533 9.966Three core 3.986 3.986 3.986 4.246 4.246 4.766 4.766 6.716 9.425 9.858 10.291Four core 4.203 4.203 4.203 4.485 4.485 4.983 4.983 7.041 9.750 10.183 10.616
HV/LV armoured distribution cables (all types)
In trenches or ducts
Fixed direct to backgrounds
Gland and terminate
Tee Cable joints
Through Cable joints
Four way Cable joints
1.5mm 2.5mm 4mm 6mm 10mm 16mm 25mm 35mm 50mm 70mm 95mm 120mm 150mmIn trunking / conduit
Single core 0.033 0.043 0.043 0.043 0.053 0.053 0.075 0.075 0.075 0.075 0.100 0.100 0.100
LV unarmoured distribution cables (all types)
104
0.9mm6 Pair 0.10310 Pair 0.03920 Pair 0.04350 Pair 0.1566 Pair 1.40310 Pair 2.71420 Pair 4.03450 Pair 7.535
Telephone cable (all types)
Fixed direct to backgrounds
Gland and terminate
n.e 1.5mm
2 Pair 0.07510 Pair 0.09020 Pair 0.1002 Pair 0.66310 Pair 2.46720 Pair 3.667
Armoured Thermocouple cable (all types)
Fixed direct to backgrounds
Gland and terminate
n.e 1.5mm
2.5mm 4mm
Fixed direct to backgrounds
n.e. 4 Core 0.335 0.335 0.335
In trunking / conduit
n.e. 4 Core 0.029 0.033 0.037
Gland and terminate
n.e. 4 Core 0.216 0.216 0.250
Flexible distribution cable (all types)
105
Unit Hrsn.e. 6 Core 2.551Over 6 n.e. 12 Core 3.824Over 12 n.e. 18 Core 4.286Over 18 n.e. 24 Core 5.448Over 24 n.e. 30 Core 7.010Over 30 n.e. 36 Core 8.741
Fibre Optic cable (all types)
Fixed direct to backgrounds
Unit Hrsn.e. 5mm OD 0.056Over 5 n.e. 10mm OD 0.068Over 10 n.e. 20mm OD 0.092Over 20 n.e. 30mm OD 0.136n.e. 5mm OD 1.896Over 5 n.e. 10mm OD 2.276Over 10 n.e. 20mm OD 3.036Over 20 n.e. 30mm OD 3.795
Co-axial cable (all types)
Gland and terminate
Fixed direct to backgrounds
106
1.5mm 2.5mm 4mm5 core 0.086 0.086 0.1087 core 0.086 0.108 0.13010 core 0.108 0.130 0.19512 core 0.108 0.130 0.23819 core 0.130 0.173 0.26027 core 0.173 0.216 0.28137 core 0.216 0.28148 core 0.238 0.3255 core 0.129 0.205 0.2387 core 0.129 0.238 0.31410 core 0.205 0.281 0.43312 core 0.238 0.314 0.45419 core 0.314 0.422 0.49827 core 0.422 0.465 0.54137 core 0.454 0.50948 core 0.498 0.5525 core 0.823 0.823 0.8667 core 0.953 0.953 0.99610 core 1.105 1.105 1.21312 core 1.105 1.105 1.21319 core 1.365 1.365 1.47327 core 1.668 1.668 1.84137 core 2.015 2.01548 core 2.773 2.773
Multicore armoured Control cables (all types)
In trenches or ducts
Fixed direct to backgrounds
Gland and terminate
107
n.e 1.5mm
n.e. 1.5mm
1 Pair 0.0291 Triple 0.0352 Pair 0.0293 Pair 0.0354 Pair 0.0395 Pair 0.0436 Pair 0.0466 Triple 0.0577 Pair 0.0507 Triple 0.0628 Pair 0.05310 Pair 0.05712 Pair 0.06212 Triple 0.07220 Pair 0.07236 Pair 0.08650 Pair 0.096100 Pair 0.1441 Pair 0.0721 Quad 0.0751 Triple 0.0722 Pair 0.0723 Pair 0.0904 Pair 0.1105 Pair 0.1305 Quad 0.0906 Pair 0.1336 Triple 0.1447 Pair 0.1367 Triple 0.1508 Pair 0.13910 Pair 0.14410 Quad 0.10012 Pair 0.15012 Triple 0.17320 Pair 0.17336 Pair 0.20850 Pair 0.231100 Pair 0.346
Multi-paired unarmoured Instrumentation Cables (all types)
In trenches or ducts
Fixed direct to backgrounds
108
n.e 1.5mm
n.e. 1.5mm
1 Pair 0.2841 Quad 0.6631 Triple 0.4232 Pair 0.4233 Pair 0.5604 Pair 0.7005 Pair 0.8535 Quad 2.4676 Pair 1.0506 Triple 1.4307 Pair 1.2307 Triple 1.6108 Pair 1.40010 Pair 1.60210 Quad 3.66712 Pair 1.90012 Triple 3.09020 Pair 3.12736 Pair 5.36050 Pair 7.444100 Pair 14.887
Multi-paired unarmoured Instrumentation Cables (Col lective screened)
Terminate
109
n.e 1.5mm
n.e. 1.5mm
1 Pair 0.3551 Quad 0.8292 Pair 0.5293 Pair 0.6904 Pair 0.8605 Pair 1.0665 Quad 3.0836 Pair 1.2507 Pair 1.4908 Pair 1.70010 Pair 2.00210 Quad 4.58312 Pair 2.40020 Pair 3.90936 Pair 6.70150 Pair 9.306100 Pair 18.610
Multi-paired unarmoured Instrumentation Cables (Ind ividual and Collective screened)
Terminate
110
2.5 to 4.0mm2
6.0 to 10.0mm2
16.0 to 25.0mm2
35.0 to 50.0mm2
n.e. 50mm Dia.
Over 50mm n.e. 75mm
Dia.
70.0 to 95.0mm2
120.0 to 150.0mm2
15A to 100A TP
150A to 200A TP
25mm x 3mm
30A to 80A DP
(blank)
Fixed direct to backgrounds 0.086 0.151 0.216 0.245 0.315 0.425Terminate 0.200 0.200 0.250 0.250 0.275 0.275Crimped Joint 0.200 0.200 0.250 0.250 0.275 0.275Thermal welded Joint 0.250 0.250 0.275 0.285 0.290 0.350Aluminium Tape 0.346Bi-metal Connector 0.216Central bolt test clamp 0.173Copper Tape, Plastic Coated 0.390DC tape clip metal 0.065DC tape clip plastic 0.053Disconnect Link 0.541Disconnect Link Metal Channel 0.433Earth Lattice Plate 1.300Earth Plate solid Copper 1.300Flat Saddle with Elevation Rod Air Terminal 1.625Screw down tape clamp 0.216Square tape clamp 0.216Tape saddles 0.108Through test or junction clamp 0.260Install RCCB's complete with Weatherproof or Metal Enclosures RCCB's 2.166 2.600 1.950Fixing a Mechanical Earth Clamp to Pipe Earth Clamps to pipe 0.303 0.368Install Earth Electrode Inspection Pit and Cover Earth Pit 0.650Fitting Earth Rod Clamp 0.216Install Earth Rod into average ground 1200mm 0.325Fabricate & Install Earthing Busbar 2.150Install only Earthing Busbar 1.550
Electrical earthing (Install)
Unarmoured Earthing Cables
Earthing accessories
Lightning Conductor Equipment
Single core
Earthing Busbars
Earth Rods and Clamps
111
J.2.8 Electrical Accessories Installation
Unit HrsRemote Control Units 0.850 Safety Switches 0.650 Convenience Socket Outlet 230V 2.000 Flameproof Lighting Switches 0.650 telephone outlet 0.490 Welding Socket Outlet 100A 2.500
n.e.20 way junction or marshalling box complete with Kippon type terminals 1.000 21 to 40 way junction or marshalling box complete with Kippon type terminals 1.800 41 to 80 way junction or marshalling box complete with Kippon type terminals 2.300 81 to 120 way junction or marshalling box complete with Kippon type terminals 2.600 121 to 160 way junction or marshalling box complete with Kippon type terminals 2.900 161 to 200 way junction or marshalling box complete with Kippon type terminals 3.200 201 to 400 way junction or marshalling box complete with Kippon type terminals 3.500
Make up Critchley Ident and fit carrier to cable 0.072 Fit Partex Ferrule numbers and pin crimp to each core. 0.072 Traffolyte Labels 0.215 Adaptable box 300mm x 300mm 0.606 Adaptable box 600mm x 600mm 0.780 Adaptable box 900mm x 900mm 1.300 Pack transit frame 0.429 Unpack Transit frame 0.429
Electrical Accessories (Install)
Junction or marshalling box
Switches & Outlets
Cable identification markers
Junction or marshalling box
Transit frames
112
J.2.9 Light Fittings Installation
Unit HrsFlameproof fluorescents
1x1500/2400 2.600 1x600/1200 2.275 2x1500/2400 3.791 2x600/1200 2.166 Bulkhead 1.625
Standard / Emergency LuminairesSingle Bulkhead 1.625 Twin Bulkhead 1.857 Single Overhead 2.321 Twin Overhead 3.095 Triple Overhead 3.250 "Exit" light 1.625
Explosion Proof LuminairesSingle Overhead 3.560 Single Bulkhead 2.476 Twin Bulkhead 2.786 Twin Overhead 4.643 Triple Overhead 4.952
Floodlightsn.e. 150w HPS Floodlight 3.300 250w HPS Floodlight 3.637 400w HPS Floodlight 4.256 600w HPS Floodlight 4.836 1000w HPS Floodlight 5.417
MiscLighting Dimmer Control 1.170 Floodlight Control 1.780 Portable Lamp with Charger 1.780
Plant re-lampingOverhead / Bulkhead Fitting 0.600 Fluorescent Fitting 0.800
Light Fittings (Install)
113
J.2.10 Electrical Switchgear Installation
Unit Hrs15A 0.390 30A 0.455 60A 0.390 100A 0.455 15A 1.256 30A 1.256 60A 1.451 100A 1.841 15A 1.300 30A 1.300 60A 1.408 100A 2.058 15A 1.148 30A 1.148 60A 1.408 100A 2.058 15A 1.408 30A 1.408 60A 1.625 100A 2.058 15A 1.690 30A 1.690 60A 1.841 100A 2.275 60A 2.015 100A 2.491 200A 3.250 60A 2.015 100A 2.491 200A 3.250 60A 1.950 100A 2.166 200A 5.936 60A 2.816 100A 3.120 200A 6.976 15A & 30A 1.950 60A 3.683 100A 4.073 200A 8.016 15A & 30A 2.730
8 way 15A & 30A 3.510
Switch fuses TP&N
Switch fuses SP&N 500V
Switch fuses DP 500V
Electrical switchgear (Install)
2 way
4 way
6 way
Isolators SP&N or DP
Isolators TP
Isolators TP&N
Switch fuses SP&N or DP
Metalclad MCB distribution boards TP&N
Switch fuses TP
114
Unit Hrs450mm 2.058 600mm 2.383 900mm 2.893 1400mm 4.225 1800mm 4.658 100A to 400A 0.325 500A to 800A 0.541 100A 0.260 20A to 60A 0.216 Cable Connectors 0.033 Crimp termination and screw down clamp 0.033 Cable Connectors 0.043 Crimp termination and screw down clamp 0.043 Cable Connectors 0.053 Crimp termination and screw down clamp 0.053
50 to 95mm Crimp termination and screw down clamp 0.033 120 to 150mm Crimp termination and screw down clamp 0.043 185 to 240mm Crimp termination and screw down clamp 0.053 300 to 400mm Crimp termination and screw down clamp 0.053
Floor mounted 13.000 Wall mounted 15.000 Stop/Start 0.813 Emergency Stop 0.688 Indicating Emergency Stop 0.813 Local/remote 0.813 Auto Manual 1.375 Field Control Station 1.063 Duty Selector 1.375
Electrical switchgear (Install)
16 to 35mm
Control Cubicles & MCB Control Panels
Local Control Stations
Busbar coupling links
Busbar clamps
Busbar chambers
1 to 4mm
6 to 10mm
Busbar accessories
115
J.2.11 Instrument Pipework
Unit HrsUPVC / HDPE tubing & fittings (Fabricate & Install)
n.e. 15mm ID 0.429 over 15mm n.e. 20mm ID 0.488 over 20mm n.e. 25mm ID 0.585
Galvanised Carbon steel pipe & fittings (Fabricate & Install)n.e. 15mm ID 1.014 over 15mm n.e. 20mm ID 1.268 over 20mm n.e. 25mm ID 1.500
Copper tubing & fittings (PVC covered) (Fabricate & Install)6mm OD 0.372 8mm OD 0.423 10mm OD 0.592
Stainless Steel/Incolloy tubing & fittings (Fabricate & Install)6mm OD 0.790 8mm OD 0.874 10mm OD 1.223
Valve (all materials/ratings) (Install)n.e. 15mm ID 0.300 over 15mm n.e. 20mm ID 0.250 over 20mm n.e. 25mm ID 0.400
Manifold 1 Valve (all materials/ratings) (Install)n.e. 15mm ID 0.250 over 15mm n.e. 20mm ID 0.300 over 20mm n.e. 25mm ID 0.350
Manifold 2 Valve (all materials/ratings) (Install)n.e. 15mm ID 0.300
Manifold 3 Valve (all materials/ratings) (Install)n.e. 15mm ID 0.400
Manifold 4 Valve (all materials/ratings) (Install)n.e. 15mm ID 0.400
Manifold 5 Valve (all materials/ratings) (Install)n.e. 15mm ID 0.450
Manifold 10 Valve (all materials/ratings) (Install)n.e. 15mm ID 1.200
Intrument Pipework
116
J.2.12 Instrument Equipment
Unit HrsIndicator 0.890 Recorder 1.160 Gauge 0.890 Quantity indicator 1.780 In line transmitter 1.200 Alarm 1.000 Controller 1.330 Element 1.000 Switch 1.200 Transmitter 1.160 Indicator 0.333 Recorder 0.333 Gauge 0.333 Quantity indicator 0.333 Alarm 0.333 Controller 0.333 Element 0.333 Switch 0.333 Transmitter 0.333 Indicator 1.333 Recorder 1.778 Gauge 1.333 Quantity indicator 2.444 In line transmitter 1.556 Alarm 1.644 Controller 1.778 Element 1.644 Switch 1.778 Transmitter 1.778 Indicator 1.000 Recorder 1.560 Gauge 1.000 Alarm 1.330 Controller 2.670 Element 1.110 Switch 1.330 Transmitter 1.160 RTD sensor 1.110 Thermowell 1.110 Indicator 0.333 Recorder 0.333 Gauge 0.167 Alarm 0.333 Controller 0.333 Element 0.333 Switch 0.333 Transmitter 0.333 Thermowell 0.167 Indicator 1.222 Recorder 1.644 Gauge 1.644 Alarm 2.222 Controller 2.222 Element 1.644 Switch 2.444 Transmitter 1.556 RTD sensor 1.556 Thermowell 1.556
Intrument Equipment
Install
Disconnect and re connect
Remove; Calibrate and reinstall
Install
Disconnect and re connect
Remove; Calibrate and reinstall
Flow Instruments
Temperature Instruments
117
Unit HrsIndicator 1.560 Recorder 1.780 Gauge 1.560 Alarm 1.780 Controller 2.780 Switch 1.780 Transmitter 1.780 Diff Indicator 2.000 Diff transmitter 2.000 Indicator 0.333 Recorder 0.333 Gauge 0.333 Alarm 0.333 Controller 0.333 Switch 0.333 Transmitter 0.333 Diff Indicator 0.333 Diff transmitter 0.333 Indicator 1.333 Recorder 1.556 Gauge 1.556 Alarm 1.556 Controller 1.778 Switch 1.556 Transmitter 1.556 Diff Indicator 1.556 Diff transmitter 1.556 Indicator 2.330 Recorder 2.330 Gauge 2.330 Alarm 2.330 Controller 4.200 Switch 2.800 Transmitter 4.200 Glass 2.330 Alarm lamp 1.760 Indicator 0.333 Recorder 0.333 Gauge 0.333 Alarm 0.333 Controller 0.333 Switch 0.333 Transmitter 0.333 Glass 0.333 Alarm lamp 0.333 Indicator 1.778 Recorder 1.778 Gauge 1.778 Alarm 1.778 Controller 1.778 Switch 1.778 Transmitter 1.778 Glass 1.778 Alarm lamp 1.778
Intrument Equipment
Install
Disconnect and re connect
Pressure Instruments
Disconnect and re connect
Remove; Calibrate and reinstall
InstallLevel Instruments
Remove; Calibrate and reinstall
118
Unit HrsP/I Convertor 1.560 I/P Convertor 1.560 I.S. Interface 1.110 Integrator 1.110 recorder Indicator 1.560 Probe 1.110 Air filter regulator 1.560 Annunciator 1.780 Conductivity Indicator 1.110 Transducer 1.330 P/I Convertor 0.333 I/P Convertor 0.333 I.S. Interface 0.333 Integrator 0.333 recorder Indicator 0.333 Pen recorder 0.333 Air filter regulator 0.333 P/I Convertor 2.000 I/P Convertor 2.000 I.S. Interface 1.556 Integrator 1.556 recorder Indicator 2.000 Pen recorder 2.000 Air filter regulator 1.111 approx. 650mm x 650mm x 300mm 1.750 approx. 1050mm x 650mm x 300mm 2.500 approx. 2200mm x 1200mm x 800mm 6.500 approx. 2200mm x 2400mm x 800mm 8.500 VDU Panel 4.000
Install
Disconnect and re connect
Remove; Calibrate and reinstall
Install
Intrument Equipment
Miscellaneous Instruments
Instrument Cubicle/Panel
119
J.2.13 Telecomms/CCTV/Security Equipment Installati on
Unit HrsTelecomms equipment
P.A. Access Station 7.620 Loudspeaker (internal) c/w junction box 2.860 Loudspeaker (external) c/w junction box 4.760 Internal telephone socket outlet 0.950 Internal telephone 0.480 Internal wall mounted telephone 0.950 Internal telephone hood 2.860 Line amplifier 4.760 External explosion proof mounted telephone 1.910 External telephone hood 4.760 External telephone socket outlet 1.910 Flashing Light (beacon) 2.860 Telecomms distribution box & supports (external) 4.760 Telecomms patch panel & cabinet 11.430
CCTV/Security equipment14" monitor 4.290 17" monitor 4.760 Camera c/w lens & junction box 3.810 Camera housing & heater 3.810
Telecomms/CCTV/Security equipment (Install)
J.2.14 Fire & Gas Equipment Installation
Unit HrsAudible & Visual Alarms
Alarm Sounder 0.975 Alarm Sounder & light 1.386 Flashing Light (Strobe) 1.300 Siren, fire alarm type 0.975 Warbler alarm 0.975
DetectorsHeat detector and base 0.866 Oil Mist detector 1.160 Gas detector (all types) and base 1.300 Flame detector 1.160 Smoke detector (all types) and base 1.300
Control & InitiationReceiver (all types) 1.300 Break glass FA contacts 0.520 Deluge release call point 1.160 Fire alarm control panel 2.600 Transmitter (all types) 1.300
Fire & Gas Equipment (Install)
120
J.2.15 Heat Tracing
Unit HrsTo Pipework - straight taped
n.e. 150mm diameter 0.150 Over 150mm n.e. 300mm diameter 0.183 Over 300mm n.e. 450mm diameter 0.216
To Instrument pipework - straight tapedn.e. 15mm diameter 0.100
To Pipework - spiral tapedn.e. 150mm diameter 0.200 Over 150mm n.e. 300mm diameter 0.233 Over 300mm n.e. 450mm diameter 0.250
To Instrument pipework - spiral tapedn.e. 15mm diameter 0.166
To Vessels and the like - spiral tapedn.e. 3.00m circumference 0.250 Over 3.00m n.e. 4.50m circumference 0.283 Over 4.50m n.e. 6.00m circumference 0.316 Over 6.00m n.e. 10.00m circumference 0.350
Trace Heating Junction Box - fixed to pipe 0.416 Trace Heating Thermostat - fixed to pipe 0.416 Gland & Terminate Trace Heating tape 0.500 End termination using cold shrink end seal 0.300 Through joint using cold shrink joint kit 0.800 Compression cable gland 0.400
Heat Tracing (Install)
121
J.2.16 Testing
Unit HrsPolarity Test 0.278 Electrical separation of circuits 0.278 Protection against direct contact 0.278 Earth Loop Impedance Test 0.416 Operation of Residual Current Protective Devices 0.416 Functional testing of loops; up to 5 items
Pressure 3.796 Level 3.796 Flow 3.796 Temperature 2.496
Testing
122
L.1 Insulation Norms
L.2.1 Base Preformed Section Norms (Mineral Wool) PREFORMED SECTION: UP TO 0.7mm ALUZINC, ALUMINIUM F LAT OR STAINLESS STEELROLLED CASING TO PIPEWORK
n.e. 62mm Insulation Thickness Unit
Norm Norm Norm Norm NormNew Complete Specification m 0.259 0.315 0.397 0.509 0.607
Extra over Elbow or Bend Nr 0.181 0.220 0.277 0.356 0.424
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.090 0.110 0.138 0.178 0.212
Extra over Flange Joint-mineral wool Nr 0.258 0.315 0.395 0.509 0.606
Extra over Flange Joint-foamglass Nr 0.310 0.378 0.475 0.611 0.727
Extra over Valve or Strainer-mineral wool Nr 0.387 0.472 0.593 0.763 0.909
Extra over Valve or Strainer-foamglass Nr 0.465 0.567 0.712 0.916 1.091
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.271 0.331 0.415 0.534 0.636
Strip and remove to skip-Insulation and Cladding m 0.141 0.174 0.217 0.279 0.335
Extra over Elbow or Bend Nr 0.099 0.121 0.152 0.196 0.233
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.050 0.061 0.076 0.098 0.117
Extra over Flange Joint-mineral wool or Foamglass Nr 0.142 0.173 0.217 0.280 0.333
Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.213 0.260 0.326 0.420 0.500
Strip and remove to skip-Cladding only m 0.098 0.121 0.151 0.197 0.233
Strip and store-Insulation and Cladding m 0.197 0.239 0.302 0.390 0.463
Strip and store-Cladding m 0.138 0.167 0.210 0.272 0.325
Strip, store and refit-Insulation and Cladding m 0.443 0.541 0.679 0.873 1.040
Strip, store and refit-Cladding m 0.308 0.377 0.476 0.610 0.728
Strip, store and refit-Cladding;remove and renew Insulation m 0.430 0.525 0.659 0.846 1.010
Extra over Elbow or Bend Nr 0.301 0.367 0.461 0.593 0.706
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.150 0.184 0.230 0.297 0.353
Extra over Flange Joint-mineral wool Nr 0.430 0.524 0.658 0.847 1.009
Extra over Valve or Strainer-mineral wool Nr 0.645 0.787 0.988 1.271 1.514
Strip, remove and renew Cladding only m 0.279 0.341 0.430 0.551 0.656
Strip, remove and renew complete specification m 0.400 0.489 0.614 0.787 0.938
Extra over Elbow or Bend Nr 0.280 0.342 0.429 0.552 0.658
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.140 0.171 0.215 0.276 0.329
Extra over Flange Joint-mineral wool Nr 0.400 0.488 0.613 0.789 0.939
Extra over Flange Joint-foamglass Nr 0.480 0.586 0.735 0.946 1.127
Extra over Valve or Strainer-mineral wool Nr 0.600 0.732 0.919 1.183 1.409
Extra over Valve or Strainer-foamglass Nr 0.720 0.879 1.103 1.420 1.691
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.420 0.513 0.644 0.828 0.986
Over 150mm n.e. 250mm
Pipe Size
n.e. 50mm Over 350mm n.e. 500mm
Over 250mm n.e. 350mm
Over 50mm n.e. 150mm
123
PREFORMED SECTION: UP TO 0.7mm ALUZINC, ALUMINIUM F LAT OR STAINLESS STEELROLLED CASING TO PIPEWORK
n.e. 62mm Insulation Thickness Unit
Norm Norm Norm Norm NormNew Complete Specification m 0.727 0.788 0.848 0.908 0.969Extra over Elbow or Bend Nr 0.509 0.551 0.594 0.636 0.479Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.255 0.276 0.297 0.318 0.339Extra over Flange Joint-mineral wool Nr 0.727 0.788 0.848 0.908 0.969Extra over Flange Joint-foamglass Nr 0.873 0.945 1.018 1.090 1.163Extra over Valve or Strainer-mineral wool Nr 1.091 1.181 1.272 1.363 1.454Extra over Valve or Strainer-foamglass Nr 1.309 1.418 1.527 1.635 1.745Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.764 0.827 0.891 0.954 1.018
Pipe SizeOver 500mm n.e. 600mm
650mm 700mm 750mm 800mm
PREFORMED SECTION: UP TO 0.7mm ALUZINC, ALUMINIUM F LAT OR STAINLESS STEELROLLED CASING TO PIPEWORK
n.e. 62mm Insulation Thickness UnitNorm Norm Norm Norm Norm
New Complete Specification m 1.091 1.273 1.455 1.636 1.818Extra over Elbow or Bend Nr 0.763 0.891 1.018 1.146 1.273Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.382 0.445 0.509 0.573 0.636Extra over Flange Joint-mineral wool Nr 1.091 1.273 1.455 1.636 1.818Extra over Flange Joint-foamglass Nr 1.309 1.527 1.746 1.964 2.182Extra over Valve or Strainer-mineral wool Nr 1.636 1.909 2.182 2.455 2.727Extra over Valve or Strainer-foamglass Nr 1.963 2.291 2.618 2.946 3.273Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.145 1.336 1.527 1.718 1.909
Pipe Size900mm 1100mm 1200mm 1400mm 1500mm
124
PREFORMED SECTION: UP TO 0.7mm ALUZINC, ALUMINIUM F LAT OR STAINLESS STEELROLLED CASING TO PIPEWORK
Over 62mm n.e. 112mm Insulation Thickness
Norm Norm Norm Norm NormNew Complete Specification m 0.371 0.420 0.525 0.663 0.768
Extra over Elbow or Bend Nr 0.260 0.293 0.368 0.463 0.537
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.130 0.147 0.184 0.232 0.268
Extra over Flange Joint-mineral wool Nr 0.372 0.419 0.525 0.662 0.767
Extra over Flange Joint-foamglass Nr 0.446 0.503 0.630 0.794 0.920
Extra over Valve or Strainer-mineral wool Nr 0.557 0.629 0.788 0.993 1.151
Extra over Valve or Strainer-foamglass Nr 0.669 0.755 0.945 1.191 1.381
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.390 0.440 0.551 0.695 0.805
Strip and remove to skip-Insulation and Cladding m 0.203 0.230 0.289 0.364 0.423
Extra over Elbow or Bend Nr 0.143 0.161 0.202 0.255 0.295
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.072 0.081 0.101 0.127 0.148
Extra over Flange Joint-mineral wool or Foamglass Nr 0.204 0.231 0.289 0.364 0.422
Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.307 0.346 0.433 0.546 0.633
Strip and remove to skip-Cladding only m 0.144 0.161 0.203 0.256 0.295
Strip and store-Insulation and Cladding m 0.285 0.322 0.400 0.505 0.587
Strip and store-Cladding m 0.200 0.223 0.282 0.354 0.410
Strip, store and refit-Insulation and Cladding m 0.636 0.718 0.902 1.135 1.316
Strip, store and refit-Cladding m 0.446 0.502 0.630 0.794 0.922
Strip, store and refit-Cladding;remove and renew Insulation m 0.620 0.699 0.876 1.102 1.276
Extra over Elbow or Bend Nr 0.433 0.489 0.612 0.771 0.894
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.217 0.244 0.306 0.386 0.447
Extra over Flange Joint-mineral wool Nr 0.619 0.698 0.874 1.102 1.277
Extra over Valve or Strainer-mineral wool Nr 0.928 1.047 1.311 1.653 1.916
Strip, remove and renew Cladding only m 0.404 0.456 0.571 0.718 0.833
Strip, remove and renew complete specification m 0.577 0.650 0.814 1.027 1.188
Extra over Elbow or Bend Nr 0.403 0.455 0.570 0.718 0.832
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.202 0.227 0.285 0.359 0.416
Extra over Flange Joint-mineral wool Nr 0.576 0.650 0.814 1.026 1.189
Extra over Flange Joint-foamglass Nr 0.691 0.780 0.977 1.231 1.427
Extra over Valve or Strainer-mineral wool Nr 0.864 0.975 1.221 1.539 1.783
Extra over Valve or Strainer-foamglass Nr 1.037 1.170 1.465 1.846 2.140
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.605 0.682 0.854 1.077 1.248
n.e. 50mm Over 50mm n.e. 150mm
Pipe SizeOver 150mm n.e. 250mm
Over 350mm n.e. 500mm
Over 250mm n.e. 350mm
125
PREFORMED SECTION: UP TO 0.7mm ALUZINC, ALUMINIUM F LAT OR STAINLESS STEELROLLED CASING TO PIPEWORK
Over 62mm n.e. 112mm Insulation Thickness Unit
Norm Norm Norm Norm NormNew Complete Specification m 0.920 0.997 1.074 1.150 1.227Extra over Elbow or Bend Nr 0.644 0.698 0.752 0.805 0.859Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.322 0.349 0.376 0.402 0.429Extra over Flange Joint-mineral wool Nr 0.920 0.997 1.074 1.150 1.227Extra over Flange Joint-foamglass Nr 1.105 1.196 1.288 1.380 1.472Extra over Valve or Strainer-mineral wool Nr 1.381 1.495 1.610 1.725 1.840Extra over Valve or Strainer-foamglass Nr 1.657 1.794 1.932 2.070 2.208Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.966 1.047 1.127 1.207 1.288
Pipe SizeOver 500mm n.e. 600mm
650mm 700mm 750mm 800mm
PREFORMED SECTION: UP TO 0.7mm ALUZINC, ALUMINIUM F LAT OR STAINLESS STEELROLLED CASING TO PIPEWORK
Over 62mm n.e. 112mm Insulation Thickness UnitNorm Norm Norm Norm Norm
New Complete Specification m 1.380 1.611 1.841 2.071 2.301Extra over Elbow or Bend Nr 0.966 1.128 1.289 1.450 1.611Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.483 0.564 0.644 0.725 0.805Extra over Flange Joint-mineral wool Nr 1.380 1.611 1.841 2.071 2.301Extra over Flange Joint-foamglass Nr 1.656 1.933 2.209 2.485 2.761Extra over Valve or Strainer-mineral wool Nr 2.070 2.416 2.762 3.107 3.452Extra over Valve or Strainer-foamglass Nr 2.484 2.899 3.314 3.728 4.142Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.449 1.691 1.933 2.175 2.416
Pipe Size900mm 1100mm 1200mm 1400mm 1500mm
126
PREFORMED SECTION: UP TO 0.7mm ALUZINC, ALUMINIUM F LAT OR STAINLESS STEELROLLED CASING TO PIPEWORK
Over 112mm n.e. 150mm Insulation Thickness
Norm Norm Norm Norm NormNew Complete Specification m 0.515 0.663 0.823 0.951
Extra over Elbow or Bend Nr 0.361 0.463 0.576 0.667
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.181 0.232 0.288 0.333
Extra over Flange Joint-mineral wool Nr 0.516 0.662 0.823 0.952
Extra over Flange Joint-foamglass Nr 0.620 0.794 0.988 1.143
Extra over Valve or Strainer-mineral wool Nr 0.775 0.993 1.235 1.429
Extra over Valve or Strainer-foamglass Nr 0.930 1.191 1.482 1.714
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.542 0.695 0.864 1.000
Strip and remove to skip-Insulation and Cladding m 0.285 0.364 0.453 0.525
Extra over Elbow or Bend Nr 0.199 0.255 0.317 0.367
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.099 0.127 0.158 0.183
Extra over Flange Joint-mineral wool or Foamglass Nr 0.284 0.364 0.453 0.524
Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.426 0.546 0.679 0.786
Strip and remove to skip-Cladding only m 0.200 0.256 0.318 0.367
Strip and store-Insulation and Cladding m 0.394 0.505 0.630 0.728
Strip and store-Cladding m 0.276 0.354 0.440 0.509
Strip, store and refit-Insulation and Cladding m 0.886 1.135 1.411 1.634
Strip, store and refit-Cladding m 0.620 0.794 0.988 1.142
Strip, store and refit-Cladding;remove and renew Insulation m 0.860 1.102 1.371 1.585
Extra over Elbow or Bend Nr 0.602 0.771 0.959 1.110
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.301 0.386 0.480 0.555
Extra over Flange Joint-mineral wool Nr 0.860 1.102 1.371 1.586
Extra over Valve or Strainer-mineral wool Nr 1.290 1.653 2.056 2.378
Strip, remove and renew Cladding only m 0.561 0.718 0.892 1.033
Strip, remove and renew complete specification m 0.801 1.027 1.276 1.476
Extra over Elbow or Bend Nr 0.560 0.718 0.893 1.033
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.280 0.359 0.447 0.517
Extra over Flange Joint-mineral wool Nr 0.800 1.026 1.276 1.476
Extra over Flange Joint-foamglass Nr 0.961 1.231 1.531 1.771
Extra over Valve or Strainer-mineral wool Nr 1.201 1.539 1.914 2.214
Extra over Valve or Strainer-foamglass Nr 1.441 1.846 2.297 2.657
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.840 1.077 1.340 1.550
Pipe SizeOver 50mm n.e. 150mm
Over 150mm n.e. 250mm
Over 250mm n.e. 350mm
Over 350mm n.e. 500mm
n.e. 50mm
127
PREFORMED SECTION: UP TO 0.7mm ALUZINC, ALUMINIUM F LAT OR STAINLESS STEELROLLED CASING TO PIPEWORK
Over 112mm n.e. 150mm Insulation Thickness Unit
Norm Norm Norm Norm NormNew Complete Specification m 1.143 1.238 1.333 1.428 1.523Extra over Elbow or Bend Nr 0.800 0.866 0.933 0.999 1.066Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.400 0.433 0.467 0.500 0.533Extra over Flange Joint-mineral wool Nr 1.143 1.238 1.333 1.428 1.523Extra over Flange Joint-foamglass Nr 1.371 1.485 1.600 1.713 1.828Extra over Valve or Strainer-mineral wool Nr 1.714 1.857 1.999 2.141 2.285Extra over Valve or Strainer-foamglass Nr 2.057 2.228 2.399 2.570 2.742Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.200 1.300 1.400 1.499 1.599
Pipe SizeOver 500mm n.e. 600mm
650mm 700mm 750mm 800mm
PREFORMED SECTION: UP TO 0.7mm ALUZINC, ALUMINIUM F LAT OR STAINLESS STEELROLLED CASING TO PIPEWORK
Over 112mm n.e. 150mm Insulation Thickness UnitNorm Norm Norm Norm Norm
New Complete Specification m 1.714 2.000 2.286 2.572 2.857Extra over Elbow or Bend Nr 1.200 1.400 1.600 1.800 2.000Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.600 0.700 0.800 0.900 1.000Extra over Flange Joint-mineral wool Nr 1.714 2.000 2.286 2.572 2.857Extra over Flange Joint-foamglass Nr 2.056 2.400 2.743 3.086 3.428Extra over Valve or Strainer-mineral wool Nr 2.571 3.000 3.429 3.857 4.285Extra over Valve or Strainer-foamglass Nr 3.085 3.600 4.114 4.629 5.143Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.799 2.100 2.400 2.700 3.000
Pipe Size900mm 1100mm 1200mm 1400mm 1500mm
128
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.079 0.079 0.079 0.079 0.108 0.113Extra over Elbow or Bend Nr 0.181 0.181 0.181 0.181 0.249 0.260Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.090 0.090 0.090 0.090 0.124 0.130Extra over Flange Joint-mineral wool Nr 0.258 0.258 0.258 0.258 0.355 0.372Extra over Flange Joint-foamglass Nr 0.310 0.310 0.310 0.310 0.427 0.446Extra over Valve or Strainer-mineral wool Nr 0.387 0.387 0.387 0.387 0.533 0.557Extra over Valve or Strainer-foamglass Nr 0.465 0.465 0.465 0.465 0.640 0.669Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.271 0.271 0.271 0.271 0.373 0.390Strip, remove and renew complete specification ft 0.122 0.122 0.122 0.122 0.168 0.176Extra over Elbow or Bend Nr 0.280 0.280 0.280 0.280 0.386 0.403Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.140 0.140 0.140 0.140 0.193 0.202Extra over Flange Joint-mineral wool Nr 0.400 0.400 0.400 0.400 0.551 0.576Extra over Flange Joint-foamglass Nr 0.480 0.480 0.480 0.480 0.661 0.691Extra over Valve or Strainer-mineral wool Nr 0.600 0.600 0.600 0.600 0.826 0.864Extra over Valve or Strainer-foamglass Nr 0.720 0.720 0.720 0.720 0.992 1.037Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.420 0.420 0.420 0.420 0.578 0.605Strip and remove to skip-Insulation and Cladding ft 0.043 0.043 0.043 0.043 0.060 0.062Extra over Elbow or Bend Nr 0.099 0.099 0.099 0.099 0.137 0.143Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.050 0.050 0.050 0.050 0.068 0.072Extra over Flange Joint-mineral wool or Foamglass Nr 0.142 0.142 0.142 0.142 0.195 0.204Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.213 0.213 0.213 0.213 0.293 0.307Strip and remove to skip-Cladding only ft 0.030 0.030 0.030 0.030 0.042 0.044Strip and store-Insulation and Cladding ft 0.060 0.060 0.060 0.060 0.083 0.087Strip and store-Cladding ft 0.042 0.042 0.042 0.042 0.058 0.061Strip, store and refit-Insulation and Cladding ft 0.135 0.135 0.135 0.135 0.186 0.194Strip, store and refit-Cladding ft 0.094 0.094 0.094 0.094 0.130 0.136Strip, store and refit-Cladding;remove and renew Insulation ft 0.131 0.131 0.131 0.131 0.180 0.189Extra over Elbow or Bend Nr 0.301 0.301 0.301 0.301 0.414 0.433Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.150 0.150 0.150 0.150 0.207 0.217Extra over Flange Joint-mineral wool Nr 0.430 0.430 0.430 0.430 0.592 0.619Extra over Valve or Strainer-mineral wool Nr 0.645 0.645 0.645 0.645 0.888 0.928Strip, remove and renew Cladding only ft 0.085 0.085 0.085 0.085 0.118 0.123
1/2" pipe size Unit 1" 1 1/2" 2" 2 1/2" 3" 4"Insulation Thickness
129
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.079 0.079 0.079 0.079 0.108 0.113Extra over Elbow or Bend Nr 0.181 0.181 0.181 0.181 0.249 0.260Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.090 0.090 0.090 0.090 0.124 0.130Extra over Flange Joint-mineral wool Nr 0.258 0.258 0.258 0.258 0.355 0.372Extra over Flange Joint-foamglass Nr 0.310 0.310 0.310 0.310 0.427 0.446Extra over Valve or Strainer-mineral wool Nr 0.387 0.387 0.387 0.387 0.533 0.557Extra over Valve or Strainer-foamglass Nr 0.465 0.465 0.465 0.465 0.640 0.669Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.271 0.271 0.271 0.271 0.373 0.390Strip, remove and renew complete specification ft 0.122 0.122 0.122 0.122 0.168 0.176Extra over Elbow or Bend Nr 0.280 0.280 0.280 0.280 0.386 0.403Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.140 0.140 0.140 0.140 0.193 0.202Extra over Flange Joint-mineral wool Nr 0.400 0.400 0.400 0.400 0.551 0.576Extra over Flange Joint-foamglass Nr 0.480 0.480 0.480 0.480 0.661 0.691Extra over Valve or Strainer-mineral wool Nr 0.600 0.600 0.600 0.600 0.826 0.864Extra over Valve or Strainer-foamglass Nr 0.720 0.720 0.720 0.720 0.992 1.037Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.420 0.420 0.420 0.420 0.578 0.605Strip and remove to skip-Insulation and Cladding ft 0.043 0.043 0.043 0.043 0.060 0.062Extra over Elbow or Bend Nr 0.099 0.099 0.099 0.099 0.137 0.143Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.050 0.050 0.050 0.050 0.068 0.072Extra over Flange Joint-mineral wool or Foamglass Nr 0.142 0.142 0.142 0.142 0.195 0.204Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.213 0.213 0.213 0.213 0.293 0.307Strip and remove to skip-Cladding only ft 0.030 0.030 0.030 0.030 0.042 0.044Strip and store-Insulation and Cladding ft 0.060 0.060 0.060 0.060 0.083 0.087Strip and store-Cladding ft 0.042 0.042 0.042 0.042 0.058 0.061Strip, store and refit-Insulation and Cladding ft 0.135 0.135 0.135 0.135 0.186 0.194Strip, store and refit-Cladding ft 0.094 0.094 0.094 0.094 0.130 0.136Strip, store and refit-Cladding;remove and renew Insulation ft 0.131 0.131 0.131 0.131 0.180 0.189Extra over Elbow or Bend Nr 0.301 0.301 0.301 0.301 0.414 0.433Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.150 0.150 0.150 0.150 0.207 0.217Extra over Flange Joint-mineral wool Nr 0.430 0.430 0.430 0.430 0.592 0.619Extra over Valve or Strainer-mineral wool Nr 0.645 0.645 0.645 0.645 0.888 0.928Strip, remove and renew Cladding only ft 0.085 0.085 0.085 0.085 0.118 0.123
3/4" pipe size Unit 3" 4"Insulation Thickness
1" 1 1/2" 2" 2 1/2"
130
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.079 0.079 0.079 0.079 0.108 0.113Extra over Elbow or Bend Nr 0.181 0.181 0.181 0.181 0.249 0.260Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.090 0.090 0.090 0.090 0.124 0.130Extra over Flange Joint-mineral wool Nr 0.258 0.258 0.258 0.258 0.355 0.372Extra over Flange Joint-foamglass Nr 0.310 0.310 0.310 0.310 0.427 0.446Extra over Valve or Strainer-mineral wool Nr 0.387 0.387 0.387 0.387 0.533 0.557Extra over Valve or Strainer-foamglass Nr 0.465 0.465 0.465 0.465 0.640 0.669Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.271 0.271 0.271 0.271 0.373 0.390Strip, remove and renew complete specification ft 0.122 0.122 0.122 0.122 0.168 0.176Extra over Elbow or Bend Nr 0.280 0.280 0.280 0.280 0.386 0.403Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.140 0.140 0.140 0.140 0.193 0.202Extra over Flange Joint-mineral wool Nr 0.400 0.400 0.400 0.400 0.551 0.576Extra over Flange Joint-foamglass Nr 0.480 0.480 0.480 0.480 0.661 0.691Extra over Valve or Strainer-mineral wool Nr 0.600 0.600 0.600 0.600 0.826 0.864Extra over Valve or Strainer-foamglass Nr 0.720 0.720 0.720 0.720 0.992 1.037Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.420 0.420 0.420 0.420 0.578 0.605Strip and remove to skip-Insulation and Cladding ft 0.043 0.043 0.043 0.043 0.060 0.062Extra over Elbow or Bend Nr 0.099 0.099 0.099 0.099 0.137 0.143Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.050 0.050 0.050 0.050 0.068 0.072Extra over Flange Joint-mineral wool or Foamglass Nr 0.142 0.142 0.142 0.142 0.195 0.204Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.213 0.213 0.213 0.213 0.293 0.307Strip and remove to skip-Cladding only ft 0.030 0.030 0.030 0.030 0.042 0.044Strip and store-Insulation and Cladding ft 0.060 0.060 0.060 0.060 0.083 0.087Strip and store-Cladding ft 0.042 0.042 0.042 0.042 0.058 0.061Strip, store and refit-Insulation and Cladding ft 0.135 0.135 0.135 0.135 0.186 0.194Strip, store and refit-Cladding ft 0.094 0.094 0.094 0.094 0.130 0.136Strip, store and refit-Cladding;remove and renew Insulation ft 0.131 0.131 0.131 0.131 0.180 0.189Extra over Elbow or Bend Nr 0.301 0.301 0.301 0.301 0.414 0.433Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.150 0.150 0.150 0.150 0.207 0.217Extra over Flange Joint-mineral wool Nr 0.430 0.430 0.430 0.430 0.592 0.619Extra over Valve or Strainer-mineral wool Nr 0.645 0.645 0.645 0.645 0.888 0.928Strip, remove and renew Cladding only ft 0.085 0.085 0.085 0.085 0.118 0.123
1" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4"
131
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.079 0.079 0.079 0.079 0.108 0.113Extra over Elbow or Bend Nr 0.181 0.181 0.181 0.181 0.249 0.260Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.090 0.090 0.090 0.090 0.124 0.130Extra over Flange Joint-mineral wool Nr 0.258 0.258 0.258 0.258 0.355 0.372Extra over Flange Joint-foamglass Nr 0.310 0.310 0.310 0.310 0.427 0.446Extra over Valve or Strainer-mineral wool Nr 0.387 0.387 0.387 0.387 0.533 0.557Extra over Valve or Strainer-foamglass Nr 0.465 0.465 0.465 0.465 0.640 0.669Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.271 0.271 0.271 0.271 0.373 0.390Strip, remove and renew complete specification ft 0.122 0.122 0.122 0.122 0.168 0.176Extra over Elbow or Bend Nr 0.280 0.280 0.280 0.280 0.386 0.403Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.140 0.140 0.140 0.140 0.193 0.202Extra over Flange Joint-mineral wool Nr 0.400 0.400 0.400 0.400 0.551 0.576Extra over Flange Joint-foamglass Nr 0.480 0.480 0.480 0.480 0.661 0.691Extra over Valve or Strainer-mineral wool Nr 0.600 0.600 0.600 0.600 0.826 0.864Extra over Valve or Strainer-foamglass Nr 0.720 0.720 0.720 0.720 0.992 1.037Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.420 0.420 0.420 0.420 0.578 0.605Strip and remove to skip-Insulation and Cladding ft 0.043 0.043 0.043 0.043 0.060 0.062Extra over Elbow or Bend Nr 0.099 0.099 0.099 0.099 0.137 0.143Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.050 0.050 0.050 0.050 0.068 0.072Extra over Flange Joint-mineral wool or Foamglass Nr 0.142 0.142 0.142 0.142 0.195 0.204Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.213 0.213 0.213 0.213 0.293 0.307Strip and remove to skip-Cladding only ft 0.030 0.030 0.030 0.030 0.042 0.044Strip and store-Insulation and Cladding ft 0.060 0.060 0.060 0.060 0.083 0.087Strip and store-Cladding ft 0.042 0.042 0.042 0.042 0.058 0.061Strip, store and refit-Insulation and Cladding ft 0.135 0.135 0.135 0.135 0.186 0.194Strip, store and refit-Cladding ft 0.094 0.094 0.094 0.094 0.130 0.136Strip, store and refit-Cladding;remove and renew Insulation ft 0.131 0.131 0.131 0.131 0.180 0.189Extra over Elbow or Bend Nr 0.301 0.301 0.301 0.301 0.414 0.433Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.150 0.150 0.150 0.150 0.207 0.217Extra over Flange Joint-mineral wool Nr 0.430 0.430 0.430 0.430 0.592 0.619Extra over Valve or Strainer-mineral wool Nr 0.645 0.645 0.645 0.645 0.888 0.928Strip, remove and renew Cladding only ft 0.085 0.085 0.085 0.085 0.118 0.123
Unit1 1/2" pipe size 1 1/2" 2" 3" 4"Insulation Thickness
1" 2 1/2"
132
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.079 0.079 0.079 0.079 0.108 0.113Extra over Elbow or Bend Nr 0.181 0.181 0.181 0.181 0.249 0.260Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.090 0.090 0.090 0.090 0.124 0.130Extra over Flange Joint-mineral wool Nr 0.258 0.258 0.258 0.258 0.355 0.372Extra over Flange Joint-foamglass Nr 0.310 0.310 0.310 0.310 0.427 0.446Extra over Valve or Strainer-mineral wool Nr 0.387 0.387 0.387 0.387 0.533 0.557Extra over Valve or Strainer-foamglass Nr 0.465 0.465 0.465 0.465 0.640 0.669Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.271 0.271 0.271 0.271 0.373 0.390Strip, remove and renew complete specification ft 0.122 0.122 0.122 0.122 0.168 0.176Extra over Elbow or Bend Nr 0.280 0.280 0.280 0.280 0.386 0.403Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.140 0.140 0.140 0.140 0.193 0.202Extra over Flange Joint-mineral wool Nr 0.400 0.400 0.400 0.400 0.551 0.576Extra over Flange Joint-foamglass Nr 0.480 0.480 0.480 0.480 0.661 0.691Extra over Valve or Strainer-mineral wool Nr 0.600 0.600 0.600 0.600 0.826 0.864Extra over Valve or Strainer-foamglass Nr 0.720 0.720 0.720 0.720 0.992 1.037Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.420 0.420 0.420 0.420 0.578 0.605Strip and remove to skip-Insulation and Cladding ft 0.043 0.043 0.043 0.043 0.060 0.062Extra over Elbow or Bend Nr 0.099 0.099 0.099 0.099 0.137 0.143Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.050 0.050 0.050 0.050 0.068 0.072Extra over Flange Joint-mineral wool or Foamglass Nr 0.142 0.142 0.142 0.142 0.195 0.204Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.213 0.213 0.213 0.213 0.293 0.307Strip and remove to skip-Cladding only ft 0.030 0.030 0.030 0.030 0.042 0.044Strip and store-Insulation and Cladding ft 0.060 0.060 0.060 0.060 0.083 0.087Strip and store-Cladding ft 0.042 0.042 0.042 0.042 0.058 0.061Strip, store and refit-Insulation and Cladding ft 0.135 0.135 0.135 0.135 0.186 0.194Strip, store and refit-Cladding ft 0.094 0.094 0.094 0.094 0.130 0.136Strip, store and refit-Cladding;remove and renew Insulation ft 0.131 0.131 0.131 0.131 0.180 0.189Extra over Elbow or Bend Nr 0.301 0.301 0.301 0.301 0.414 0.433Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.150 0.150 0.150 0.150 0.207 0.217Extra over Flange Joint-mineral wool Nr 0.430 0.430 0.430 0.430 0.592 0.619Extra over Valve or Strainer-mineral wool Nr 0.645 0.645 0.645 0.645 0.888 0.928Strip, remove and renew Cladding only ft 0.085 0.085 0.085 0.085 0.118 0.123
2" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4"
133
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.096 0.096 0.096 0.096 0.121 0.128Extra over Elbow or Bend Nr 0.220 0.220 0.220 0.220 0.277 0.293Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.110 0.110 0.110 0.110 0.138 0.147Extra over Flange Joint-mineral wool Nr 0.315 0.315 0.315 0.315 0.395 0.419Extra over Flange Joint-foamglass Nr 0.378 0.378 0.378 0.378 0.475 0.503Extra over Valve or Strainer-mineral wool Nr 0.472 0.472 0.472 0.472 0.593 0.629Extra over Valve or Strainer-foamglass Nr 0.567 0.567 0.567 0.567 0.712 0.755Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.331 0.331 0.331 0.331 0.415 0.440Strip, remove and renew complete specification ft 0.149 0.149 0.149 0.149 0.187 0.198Extra over Elbow or Bend Nr 0.342 0.342 0.342 0.342 0.429 0.455Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.171 0.171 0.171 0.171 0.215 0.227Extra over Flange Joint-mineral wool Nr 0.488 0.488 0.488 0.488 0.613 0.650Extra over Flange Joint-foamglass Nr 0.586 0.586 0.586 0.586 0.735 0.780Extra over Valve or Strainer-mineral wool Nr 0.732 0.732 0.732 0.732 0.919 0.975Extra over Valve or Strainer-foamglass Nr 0.879 0.879 0.879 0.879 1.103 1.170Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.513 0.513 0.513 0.513 0.644 0.682Strip and remove to skip-Insulation and Cladding ft 0.053 0.053 0.053 0.053 0.066 0.070Extra over Elbow or Bend Nr 0.121 0.121 0.121 0.121 0.152 0.161Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.061 0.061 0.061 0.061 0.076 0.081Extra over Flange Joint-mineral wool or Foamglass Nr 0.173 0.173 0.173 0.173 0.217 0.231Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.260 0.260 0.260 0.260 0.326 0.346Strip and remove to skip-Cladding only ft 0.037 0.037 0.037 0.037 0.046 0.049Strip and store-Insulation and Cladding ft 0.073 0.073 0.073 0.073 0.092 0.098Strip and store-Cladding ft 0.051 0.051 0.051 0.051 0.064 0.068Strip, store and refit-Insulation and Cladding ft 0.165 0.165 0.165 0.165 0.207 0.219Extra over Elbow or Bend Nr 0.000 0.000 0.378 0.000 0.475 0.000Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.000 0.000 0.189 0.000 0.237 0.000Strip, store and refit-Cladding ft 0.115 0.115 0.115 0.115 0.145 0.153Strip, store and refit-Cladding;remove and renew Insulation ft 0.160 0.160 0.160 0.160 0.201 0.213Extra over Elbow or Bend Nr 0.367 0.367 0.367 0.367 0.461 0.489Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.184 0.184 0.184 0.184 0.230 0.244Extra over Flange Joint-mineral wool Nr 0.524 0.524 0.524 0.524 0.658 0.698Extra over Valve or Strainer-mineral wool Nr 0.787 0.787 0.787 0.787 0.988 1.047Strip, remove and renew Cladding only ft 0.104 0.104 0.104 0.104 0.131 0.139
3" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4"
134
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.096 0.096 0.096 0.096 0.121 0.128Extra over Elbow or Bend Nr 0.220 0.220 0.220 0.220 0.277 0.293Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.110 0.110 0.110 0.110 0.138 0.147Extra over Flange Joint-mineral wool Nr 0.315 0.315 0.315 0.315 0.395 0.419Extra over Flange Joint-foamglass Nr 0.378 0.378 0.378 0.378 0.475 0.503Extra over Valve or Strainer-mineral wool Nr 0.472 0.472 0.472 0.472 0.593 0.629Extra over Valve or Strainer-foamglass Nr 0.567 0.567 0.567 0.567 0.712 0.755Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.331 0.331 0.331 0.331 0.415 0.440Strip, remove and renew complete specification ft 0.149 0.149 0.149 0.149 0.187 0.198Extra over Elbow or Bend Nr 0.342 0.342 0.342 0.342 0.429 0.455Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.171 0.171 0.171 0.171 0.215 0.227Extra over Flange Joint-mineral wool Nr 0.488 0.488 0.488 0.488 0.613 0.650Extra over Flange Joint-foamglass Nr 0.586 0.586 0.586 0.586 0.735 0.780Extra over Valve or Strainer-mineral wool Nr 0.732 0.732 0.732 0.732 0.919 0.975Extra over Valve or Strainer-foamglass Nr 0.879 0.879 0.879 0.879 1.103 1.170Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.513 0.513 0.513 0.513 0.644 0.682Strip and remove to skip-Insulation and Cladding ft 0.053 0.053 0.053 0.053 0.066 0.070Extra over Elbow or Bend Nr 0.121 0.121 0.121 0.121 0.152 0.161Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.061 0.061 0.061 0.061 0.076 0.081Extra over Flange Joint-mineral wool or Foamglass Nr 0.173 0.173 0.173 0.173 0.217 0.231Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.260 0.260 0.260 0.260 0.326 0.346Strip and remove to skip-Cladding only ft 0.037 0.037 0.037 0.037 0.046 0.049Strip and store-Insulation and Cladding ft 0.073 0.073 0.073 0.073 0.092 0.098Strip and store-Cladding ft 0.051 0.051 0.051 0.051 0.064 0.068Strip, store and refit-Insulation and Cladding ft 0.165 0.165 0.165 0.165 0.207 0.219Strip, store and refit-Cladding ft 0.115 0.115 0.115 0.115 0.145 0.153Strip, store and refit-Cladding;remove and renew Insulation ft 0.160 0.160 0.160 0.160 0.201 0.213Extra over Elbow or Bend Nr 0.367 0.367 0.367 0.367 0.461 0.489Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.184 0.184 0.184 0.184 0.230 0.244Extra over Flange Joint-mineral wool Nr 0.524 0.524 0.524 0.524 0.658 0.698Extra over Valve or Strainer-mineral wool Nr 0.787 0.787 0.787 0.787 0.988 1.047Strip, remove and renew Cladding only ft 0.104 0.104 0.104 0.104 0.131 0.139
Unit4" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4"
135
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.096 0.096 0.096 0.096 0.121 0.128 0.128 0.157 0.157 0.157Extra over Elbow or Bend Nr 0.220 0.220 0.220 0.220 0.277 0.293 0.293 0.361 0.361 0.361Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.110 0.110 0.110 0.110 0.138 0.147 0.147 0.181 0.181 0.181Extra over Flange Joint-mineral wool Nr 0.315 0.315 0.315 0.315 0.395 0.419 0.419 0.516 0.516 0.516Extra over Flange Joint-foamglass Nr 0.378 0.378 0.378 0.378 0.475 0.503 0.503 0.620 0.620 0.620Extra over Valve or Strainer-mineral wool Nr 0.472 0.472 0.472 0.472 0.593 0.629 0.629 0.775 0.775 0.775Extra over Valve or Strainer-foamglass Nr 0.567 0.567 0.567 0.567 0.712 0.755 0.755 0.930 0.930 0.930a Nr 0.331 0.331 0.331 0.331 0.415 0.440 0.440 0.542 0.542 0.542Strip, remove and renew complete specification ft 0.149 0.149 0.149 0.149 0.187 0.198 0.198 0.244 0.244 0.244Extra over Elbow or Bend Nr 0.342 0.342 0.342 0.342 0.429 0.455 0.455 0.560 0.560 0.560Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.171 0.171 0.171 0.171 0.215 0.227 0.227 0.280 0.280 0.280Extra over Flange Joint-mineral wool Nr 0.488 0.488 0.488 0.488 0.613 0.650 0.650 0.800 0.800 0.800Extra over Flange Joint-foamglass Nr 0.586 0.586 0.586 0.586 0.735 0.780 0.780 0.961 0.961 0.961Extra over Valve or Strainer-mineral wool Nr 0.732 0.732 0.732 0.732 0.919 0.975 0.975 1.201 1.201 1.201Extra over Valve or Strainer-foamglass Nr 0.879 0.879 0.879 0.879 1.103 1.170 1.170 1.441 1.441 1.441Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.513 0.513 0.513 0.513 0.644 0.682 0.682 0.840 0.840 0.840Strip and remove to skip-Insulation and Cladding ft 0.053 0.053 0.053 0.053 0.066 0.070 0.070 0.087 0.087 0.087Extra over Elbow or Bend Nr 0.121 0.121 0.121 0.121 0.152 0.161 0.161 0.199 0.199 0.199Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.061 0.061 0.061 0.061 0.076 0.081 0.081 0.099 0.099 0.099Extra over Flange Joint-mineral wool or Foamglass Nr 0.173 0.173 0.173 0.173 0.217 0.231 0.231 0.284 0.284 0.284Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.260 0.260 0.260 0.260 0.326 0.346 0.346 0.426 0.426 0.426Strip and remove to skip-Cladding only ft 0.037 0.037 0.037 0.037 0.046 0.049 0.049 0.061 0.061 0.061Strip and store-Insulation and Cladding ft 0.073 0.073 0.073 0.073 0.092 0.098 0.098 0.120 0.120 0.120Strip and store-Cladding ft 0.051 0.051 0.051 0.051 0.064 0.068 0.068 0.084 0.084 0.084Strip, store and refit-Insulation and Cladding ft 0.165 0.165 0.165 0.165 0.207 0.219 0.219 0.270 0.270 0.270Strip, store and refit-Cladding ft 0.115 0.115 0.115 0.115 0.145 0.153 0.153 0.189 0.189 0.189Strip, store and refit-Cladding;remove and renew Insulation ft 0.160 0.160 0.160 0.160 0.201 0.213 0.213 0.262 0.262 0.262Extra over Elbow or Bend Nr 0.367 0.367 0.367 0.367 0.461 0.489 0.489 0.602 0.602 0.602Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.184 0.184 0.184 0.184 0.230 0.244 0.244 0.301 0.301 0.301Extra over Flange Joint-mineral wool Nr 0.524 0.524 0.524 0.524 0.658 0.698 0.698 0.860 0.860 0.860Extra over Valve or Strainer-mineral wool Nr 0.787 0.787 0.787 0.787 0.988 1.047 1.047 1.290 1.290 1.290Strip, remove and renew Cladding only ft 0.104 0.104 0.104 0.104 0.131 0.139 0.139 0.171 0.171 0.171Extra over Elbow or Bend Nr 0.239
Unit6" pipe sizeInsulation Thickness
2"1 1/2"1" 2 1/2" 3" 4" 5" 5 1/2" 6"4 1/2"
136
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.121 0.121 0.121 0.121 0.153 0.157 0.157 0.199 0.199 0.199Extra over Elbow or Bend Nr 0.277 0.277 0.277 0.277 0.350 0.361 0.361 0.458 0.458 0.458Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.138 0.138 0.138 0.138 0.175 0.181 0.181 0.229 0.229 0.229Extra over Flange Joint-mineral wool Nr 0.395 0.395 0.395 0.395 0.500 0.516 0.516 0.654 0.654 0.654Extra over Flange Joint-foamglass Nr 0.475 0.475 0.475 0.475 0.600 0.620 0.620 0.784 0.784 0.784Extra over Valve or Strainer-mineral wool Nr 0.593 0.593 0.593 0.593 0.750 0.775 0.775 0.980 0.980 0.980Extra over Valve or Strainer-foamglass Nr 0.712 0.712 0.712 0.712 0.900 0.930 0.930 1.177 1.177 1.177Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.415 0.415 0.415 0.415 0.525 0.542 0.542 0.686 0.686 0.686Strip, remove and renew complete specification ft 0.187 0.187 0.187 0.187 0.236 0.244 0.244 0.309 0.309 0.309Extra over Elbow or Bend Nr 0.429 0.429 0.429 0.429 0.543 0.560 0.560 0.709 0.709 0.709Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.215 0.215 0.215 0.215 0.271 0.280 0.280 0.355 0.355 0.355Extra over Flange Joint-mineral wool Nr 0.613 0.613 0.613 0.613 0.775 0.800 0.800 1.013 1.013 1.013Extra over Flange Joint-foamglass Nr 0.735 0.735 0.735 0.735 0.930 0.961 0.961 1.216 1.216 1.216Extra over Valve or Strainer-mineral wool Nr 0.919 0.919 0.919 0.919 1.163 1.201 1.201 1.520 1.520 1.520Extra over Valve or Strainer-foamglass Nr 1.103 1.103 1.103 1.103 1.396 1.441 1.441 1.824 1.824 1.824Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.644 0.644 0.644 0.644 0.814 0.840 0.840 1.064 1.064 1.064Strip and remove to skip-Insulation and Cladding ft 0.066 0.066 0.066 0.066 0.084 0.087 0.087 0.110 0.110 0.110Extra over Elbow or Bend Nr 0.152 0.152 0.152 0.152 0.193 0.199 0.199 0.252 0.252 0.252Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.076 0.076 0.076 0.076 0.096 0.099 0.099 0.126 0.126 0.126Extra over Flange Joint-mineral wool or Foamglass Nr 0.217 0.217 0.217 0.217 0.275 0.284 0.284 0.359 0.359 0.359Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.326 0.326 0.326 0.326 0.413 0.426 0.426 0.539 0.539 0.539Strip and remove to skip-Cladding only ft 0.046 0.046 0.046 0.046 0.059 0.061 0.061 0.077 0.077 0.077Strip and store-Insulation and Cladding ft 0.092 0.092 0.092 0.092 0.117 0.120 0.120 0.152 0.152 0.152Strip and store-Cladding ft 0.064 0.064 0.064 0.064 0.082 0.084 0.084 0.107 0.107 0.107Strip, store and refit-Insulation and Cladding ft 0.207 0.207 0.207 0.207 0.262 0.270 0.270 0.342 0.342 0.342Strip, store and refit-Cladding ft 0.145 0.145 0.145 0.145 0.183 0.189 0.189 0.239 0.239 0.239Strip, store and refit-Cladding;remove and renew Insulation ft 0.201 0.201 0.201 0.201 0.254 0.262 0.262 0.332 0.332 0.332Extra over Elbow or Bend Nr 0.461 0.461 0.461 0.461 0.583 0.602 0.602 0.762 0.762 0.762Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.230 0.230 0.230 0.230 0.292 0.301 0.301 0.381 0.381 0.381Extra over Flange Joint-mineral wool Nr 0.658 0.658 0.658 0.658 0.833 0.860 0.860 1.088 1.088 1.088Extra over Valve or Strainer-mineral wool Nr 0.988 0.988 0.988 0.988 1.249 1.290 1.290 1.632 1.632 1.632Strip, remove and renew Cladding only ft 0.131 0.131 0.131 0.131 0.165 0.171 0.171 0.216 0.216 0.216Extra over Elbow or Bend Nr 0.300
8" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4" 4 1/2" 5" 6"5 1/2"
137
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.121 0.121 0.121 0.121 0.155 0.160 0.160 0.202 0.202 0.202Extra over Elbow or Bend Nr 0.277 0.277 0.277 0.277 0.356 0.368 0.368 0.463 0.463 0.463Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.138 0.138 0.138 0.138 0.178 0.184 0.184 0.232 0.232 0.232Extra over Flange Joint-mineral wool Nr 0.395 0.395 0.395 0.395 0.509 0.525 0.525 0.662 0.662 0.662Extra over Flange Joint-foamglass Nr 0.475 0.475 0.475 0.475 0.611 0.630 0.630 0.794 0.794 0.794Extra over Valve or Strainer-mineral wool Nr 0.593 0.593 0.593 0.593 0.763 0.788 0.788 0.993 0.993 0.993Extra over Valve or Strainer-foamglass Nr 0.712 0.712 0.712 0.712 0.916 0.945 0.945 1.191 1.191 1.191Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.415 0.415 0.415 0.415 0.534 0.551 0.551 0.695 0.695 0.695Strip, remove and renew complete specification ft 0.187 0.187 0.187 0.187 0.240 0.248 0.248 0.313 0.313 0.313Extra over Elbow or Bend Nr 0.429 0.429 0.429 0.429 0.552 0.570 0.570 0.718 0.718 0.718Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.215 0.215 0.215 0.215 0.276 0.285 0.285 0.359 0.359 0.359Extra over Flange Joint-mineral wool Nr 0.613 0.613 0.613 0.613 0.789 0.814 0.814 1.026 1.026 1.026Extra over Flange Joint-foamglass Nr 0.735 0.735 0.735 0.735 0.946 0.977 0.977 1.231 1.231 1.231Extra over Valve or Strainer-mineral wool Nr 0.919 0.919 0.919 0.919 1.183 1.221 1.221 1.539 1.539 1.539Extra over Valve or Strainer-foamglass Nr 1.103 1.103 1.103 1.103 1.420 1.465 1.465 1.846 1.846 1.846Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.644 0.644 0.644 0.644 0.828 0.854 0.854 1.077 1.077 1.077Strip and remove to skip-Insulation and Cladding ft 0.066 0.066 0.066 0.066 0.085 0.088 0.088 0.111 0.111 0.111Extra over Elbow or Bend Nr 0.152 0.152 0.152 0.152 0.196 0.202 0.202 0.255 0.255 0.255Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.076 0.076 0.076 0.076 0.098 0.101 0.101 0.127 0.127 0.127Extra over Flange Joint-mineral wool or Foamglass Nr 0.217 0.217 0.217 0.217 0.280 0.289 0.289 0.364 0.364 0.364Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.326 0.326 0.326 0.326 0.420 0.433 0.433 0.546 0.546 0.546Strip and remove to skip-Cladding only ft 0.046 0.046 0.046 0.046 0.060 0.062 0.062 0.078 0.078 0.078Strip and store-Insulation and Cladding ft 0.092 0.092 0.092 0.092 0.119 0.122 0.122 0.154 0.154 0.154Strip and store-Cladding ft 0.064 0.064 0.064 0.064 0.083 0.086 0.086 0.108 0.108 0.108Strip, store and refit-Insulation and Cladding ft 0.207 0.207 0.207 0.207 0.266 0.275 0.275 0.346 0.346 0.346Strip, store and refit-Cladding ft 0.145 0.145 0.145 0.145 0.186 0.192 0.192 0.242 0.242 0.242Strip, store and refit-Cladding;remove and renew Insulation ft 0.201 0.201 0.201 0.201 0.258 0.267 0.267 0.336 0.336 0.336Extra over Elbow or Bend Nr 0.461 0.461 0.461 0.461 0.593 0.612 0.612 0.771 0.771 0.771Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.230 0.230 0.230 0.230 0.297 0.306 0.306 0.386 0.386 0.386Extra over Flange Joint-mineral wool Nr 0.658 0.658 0.658 0.658 0.847 0.874 0.874 1.102 1.102 1.102Extra over Valve or Strainer-mineral wool Nr 0.988 0.988 0.988 0.988 1.271 1.311 1.311 1.653 1.653 1.653Strip, remove and renew Cladding only ft 0.131 0.131 0.131 0.131 0.168 0.174 0.174 0.219 0.219 0.219EO Tee, Reducer, Full Cap End or End Closure Plate Nr 0.150
10" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4" 4 1/2" 5" 6"5 1/2"
138
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.155 0.155 0.155 0.155 0.194 0.202 0.202 0.251 0.251 0.251Extra over Elbow or Bend Nr 0.356 0.356 0.356 0.356 0.447 0.463 0.463 0.576 0.576 0.576Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.178 0.178 0.178 0.178 0.223 0.232 0.232 0.288 0.288 0.288Extra over Flange Joint-mineral wool Nr 0.509 0.509 0.509 0.509 0.638 0.662 0.662 0.823 0.823 0.823Extra over Flange Joint-foamglass Nr 0.611 0.611 0.611 0.611 0.766 0.794 0.794 0.988 0.988 0.988Extra over Valve or Strainer-mineral wool Nr 0.763 0.763 0.763 0.763 0.957 0.993 0.993 1.235 1.235 1.235Extra over Valve or Strainer-foamglass Nr 0.916 0.916 0.916 0.916 1.148 1.191 1.191 1.482 1.482 1.482Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.534 0.534 0.534 0.534 0.670 0.695 0.695 0.864 0.864 0.864Strip, remove and renew complete specification ft 0.240 0.240 0.240 0.240 0.301 0.313 0.313 0.389 0.389 0.389Extra over Elbow or Bend Nr 0.552 0.552 0.552 0.552 0.692 0.718 0.718 0.893 0.893 0.893Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.276 0.276 0.276 0.276 0.346 0.359 0.359 0.447 0.447 0.447Extra over Flange Joint-mineral wool Nr 0.789 0.789 0.789 0.789 0.989 1.026 1.026 1.276 1.276 1.276Extra over Flange Joint-foamglass Nr 0.946 0.946 0.946 0.946 1.187 1.231 1.231 1.531 1.531 1.531Extra over Valve or Strainer-mineral wool Nr 1.183 1.183 1.183 1.183 1.483 1.539 1.539 1.914 1.914 1.914Extra over Valve or Strainer-foamglass Nr 1.420 1.420 1.420 1.420 1.780 1.846 1.846 2.297 2.297 2.297Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.828 0.828 0.828 0.828 1.038 1.077 1.077 1.340 1.340 1.340Strip and remove to skip-Insulation and Cladding ft 0.085 0.085 0.085 0.085 0.107 0.111 0.111 0.138 0.138 0.138Extra over Elbow or Bend Nr 0.196 0.196 0.196 0.196 0.246 0.255 0.255 0.317 0.317 0.317Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.098 0.098 0.098 0.098 0.123 0.127 0.127 0.158 0.158 0.158Extra over Flange Joint-mineral wool or Foamglass Nr 0.280 0.280 0.280 0.280 0.351 0.364 0.364 0.453 0.453 0.453Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.420 0.420 0.420 0.420 0.526 0.546 0.546 0.679 0.679 0.679Strip and remove to skip-Cladding only ft 0.060 0.060 0.060 0.060 0.075 0.078 0.078 0.097 0.097 0.097Extra over Elbow or Bend Nr 0.178Extra over Flange Joint-mineral wool Nr 0.255Strip and store-Insulation and Cladding ft 0.119 0.119 0.119 0.119 0.149 0.154 0.154 0.192 0.192 0.192Strip and store-Cladding ft 0.083 0.083 0.083 0.083 0.104 0.108 0.108 0.134 0.134 0.134Strip, store and refit-Insulation and Cladding ft 0.266 0.266 0.266 0.266 0.334 0.346 0.346 0.430 0.430 0.430Strip, store and refit-Cladding ft 0.186 0.186 0.186 0.186 0.233 0.242 0.242 0.301 0.301 0.301Strip, store and refit-Cladding;remove and renew Insulation ft 0.258 0.258 0.258 0.258 0.324 0.336 0.336 0.418 0.418 0.418Extra over Elbow or Bend Nr 0.593 0.593 0.593 0.593 0.744 0.771 0.771 0.959 0.959 0.959Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.297 0.297 0.297 0.297 0.372 0.386 0.386 0.480 0.480 0.480Extra over Flange Joint-mineral wool Nr 0.847 0.847 0.847 0.847 1.062 1.102 1.102 1.371 1.371 1.371Extra over Valve or Strainer-mineral wool Nr 1.271 1.271 1.271 1.271 1.593 1.653 1.653 2.056 2.056 2.056Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.890Strip, remove and renew Cladding only ft 0.168 0.168 0.168 0.168 0.211 0.219 0.219 0.272 0.272 0.272Extra over Elbow or Bend Nr 0.386 0.485 0.503Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.251Extra over Flange Joint-mineral wool Nr 0.718Extra over Valve or Strainer-mineral wool Nr 1.077
Unit12" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4" 4 1/2" 5 1/2" 6"5"
139
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.155 0.155 0.155 0.194 0.202 0.202 0.251 0.251 0.251Extra over Elbow or Bend Nr 0.356 0.356 0.356 0.447 0.463 0.463 0.576 0.576 0.576Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.178 0.178 0.178 0.223 0.232 0.232 0.288 0.288 0.288Extra over Flange Joint-mineral wool Nr 0.509 0.509 0.509 0.638 0.662 0.662 0.823 0.823 0.823Extra over Flange Joint-foamglass Nr 0.611 0.611 0.611 0.766 0.794 0.794 0.988 0.988 0.988Extra over Valve or Strainer-mineral wool Nr 0.763 0.763 0.763 0.957 0.993 0.993 1.235 1.235 1.235Extra over Valve or Strainer-foamglass Nr 0.916 0.916 0.916 1.148 1.191 1.191 1.482 1.482 1.482Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.534 0.534 0.534 0.670 0.695 0.695 0.864 0.864 0.864Strip, remove and renew complete specification ft 0.240 0.240 0.240 0.301 0.313 0.313 0.389 0.389 0.389Extra over Elbow or Bend Nr 0.552 0.552 0.552 0.692 0.718 0.718 0.893 0.893 0.893Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.276 0.276 0.276 0.346 0.359 0.359 0.447 0.447 0.447Extra over Flange Joint-mineral wool Nr 0.789 0.789 0.789 0.989 1.026 1.026 1.276 1.276 1.276Extra over Flange Joint-foamglass Nr 0.946 0.946 0.946 1.187 1.231 1.231 1.531 1.531 1.531Extra over Valve or Strainer-mineral wool Nr 1.183 1.183 1.183 1.483 1.539 1.539 1.914 1.914 1.914Extra over Valve or Strainer-foamglass Nr 1.420 1.420 1.420 1.780 1.846 1.846 2.297 2.297 2.297Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.828 0.828 0.828 1.038 1.077 1.077 1.340 1.340 1.340Strip and remove to skip-Insulation and Cladding ft 0.085 0.085 0.085 0.107 0.111 0.111 0.138 0.138 0.138Extra over Elbow or Bend Nr 0.196 0.196 0.196 0.246 0.255 0.255 0.317 0.317 0.317Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.098 0.098 0.098 0.123 0.127 0.127 0.158 0.158 0.158Extra over Flange Joint-mineral wool or Foamglass Nr 0.280 0.280 0.280 0.351 0.364 0.364 0.453 0.453 0.453Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.420 0.420 0.420 0.526 0.546 0.546 0.679 0.679 0.679Strip and remove to skip-Cladding only ft 0.060 0.060 0.060 0.075 0.078 0.078 0.097 0.097 0.097Strip and store-Insulation and Cladding ft 0.119 0.119 0.119 0.149 0.154 0.154 0.192 0.192 0.192Strip and store-Cladding ft 0.083 0.083 0.083 0.104 0.108 0.108 0.134 0.134 0.134Strip, store and refit-Insulation and Cladding ft 0.266 0.266 0.266 0.334 0.346 0.346 0.430 0.430 0.430Strip, store and refit-Cladding ft 0.186 0.186 0.186 0.233 0.242 0.242 0.301 0.301 0.301Strip, store and refit-Cladding;remove and renew Insulation ft 0.258 0.258 0.258 0.324 0.336 0.336 0.418 0.418 0.418Extra over Elbow or Bend Nr 0.593 0.593 0.593 0.744 0.771 0.771 0.959 0.959 0.959Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.297 0.297 0.297 0.372 0.386 0.386 0.480 0.480 0.480Extra over Flange Joint-mineral wool Nr 0.847 0.847 0.847 1.062 1.102 1.102 1.371 1.371 1.371Extra over Valve or Strainer-mineral wool Nr 1.271 1.271 1.271 1.593 1.653 1.653 2.056 2.056 2.056Strip, remove and renew Cladding only ft 0.168 0.168 0.168 0.211 0.219 0.219 0.272 0.272 0.272
Unit14" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4" 4 1/2" 5" 6"5 1/2"
140
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.185 0.185 0.185 0.224 0.234 0.234 0.290 0.290 0.290Extra over Elbow or Bend Nr 0.424 0.424 0.424 0.514 0.537 0.537 0.667 0.667 0.667Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.212 0.212 0.212 0.257 0.268 0.268 0.333 0.333 0.333Extra over Flange Joint-mineral wool Nr 0.606 0.606 0.606 0.735 0.767 0.767 0.952 0.952 0.952Extra over Flange Joint-foamglass Nr 0.727 0.727 0.727 0.882 0.920 0.920 1.143 1.143 1.143Extra over Valve or Strainer-mineral wool Nr 0.909 0.909 0.909 1.102 1.151 1.151 1.429 1.429 1.429Extra over Valve or Strainer-foamglass Nr 1.091 1.091 1.091 1.322 1.381 1.381 1.714 1.714 1.714Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.636 0.636 0.636 0.771 0.805 0.805 1.000 1.000 1.000Strip, remove and renew complete specification ft 0.286 0.286 0.286 0.347 0.362 0.362 0.450 0.450 0.450Extra over Elbow or Bend Nr 0.658 0.658 0.658 0.797 0.832 0.832 1.033 1.033 1.033Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.329 0.329 0.329 0.399 0.416 0.416 0.517 0.517 0.517Extra over Flange Joint-mineral wool Nr 0.939 0.939 0.939 1.139 1.189 1.189 1.476 1.476 1.476Extra over Flange Joint-foamglass Nr 1.127 1.127 1.127 1.366 1.427 1.427 1.771 1.771 1.771Extra over Valve or Strainer-mineral wool Nr 1.409 1.409 1.409 1.708 1.783 1.783 2.214 2.214 2.214Extra over Valve or Strainer-foamglass Nr 1.691 1.691 1.691 2.050 2.140 2.140 2.657 2.657 2.657Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.986 0.986 0.986 1.196 1.248 1.248 1.550 1.550 1.550Strip and remove to skip-Insulation and Cladding ft 0.102 0.102 0.102 0.123 0.129 0.129 0.160 0.160 0.160Extra over Elbow or Bend Nr 0.233 0.233 0.233 0.283 0.295 0.295 0.367 0.367 0.367Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.117 0.117 0.117 0.141 0.148 0.148 0.183 0.183 0.183Extra over Flange Joint-mineral wool or Foamglass Nr 0.333 0.333 0.333 0.404 0.422 0.422 0.524 0.524 0.524Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.500 0.500 0.500 0.606 0.633 0.633 0.786 0.786 0.786Strip and remove to skip-Cladding only ft 0.071 0.071 0.071 0.086 0.090 0.090 0.112 0.112 0.112Strip and store-Insulation and Cladding ft 0.141 0.141 0.141 0.171 0.179 0.179 0.222 0.222 0.222Strip and store-Cladding ft 0.099 0.099 0.099 0.120 0.125 0.125 0.155 0.155 0.155Strip, store and refit-Insulation and Cladding ft 0.317 0.317 0.317 0.384 0.401 0.401 0.498 0.498 0.498Strip, store and refit-Cladding ft 0.222 0.222 0.222 0.269 0.281 0.281 0.348 0.348 0.348Strip, store and refit-Cladding;remove and renew Insulation ft 0.308 0.308 0.308 0.373 0.389 0.389 0.483 0.483 0.483Extra over Elbow or Bend Nr 0.706 0.706 0.706 0.856 0.894 0.894 1.110 1.110 1.110Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.353 0.353 0.353 0.428 0.447 0.447 0.555 0.555 0.555Extra over Flange Joint-mineral wool Nr 1.009 1.009 1.009 1.223 1.277 1.277 1.586 1.586 1.586Extra over Valve or Strainer-mineral wool Nr 1.514 1.514 1.514 1.835 1.916 1.916 2.378 2.378 2.378Strip, remove and renew Cladding only ft 0.200 0.200 0.200 0.243 0.254 0.254 0.315 0.315 0.315
Unit16" pipe size 5"3" 4 1/2"Insulation Thickness
6"4"1" 1 1/2" 2" 2 1/2" 5 1/2"
141
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.185 0.185 0.185 0.224 0.234 0.234 0.305 0.305 0.305Extra over Elbow or Bend Nr 0.424 0.424 0.424 0.514 0.537 0.537 0.700 0.700 0.700Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.212 0.212 0.212 0.257 0.268 0.268 0.350 0.350 0.350Extra over Flange Joint-mineral wool Nr 0.606 0.606 0.606 0.735 0.767 0.767 1.000 1.000 1.000Extra over Flange Joint-foamglass Nr 0.727 0.727 0.727 0.882 0.920 0.920 1.200 1.200 1.200Extra over Valve or Strainer-mineral wool Nr 0.909 0.909 0.909 1.102 1.151 1.151 1.500 1.500 1.500Extra over Valve or Strainer-foamglass Nr 1.091 1.091 1.091 1.322 1.381 1.381 1.800 1.800 1.800Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.636 0.636 0.636 0.771 0.805 0.805 1.050 1.050 1.050Strip, remove and renew complete specification ft 0.286 0.286 0.286 0.347 0.362 0.362 0.473 0.473 0.473Extra over Elbow or Bend Nr 0.658 0.658 0.658 0.797 0.832 0.832 1.085 1.085 1.085Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.329 0.329 0.329 0.399 0.416 0.416 0.542 0.542 0.542Extra over Flange Joint-mineral wool Nr 0.939 0.939 0.939 1.139 1.189 1.189 1.550 1.550 1.550Extra over Flange Joint-foamglass Nr 1.127 1.127 1.127 1.366 1.427 1.427 1.860 1.860 1.860Extra over Valve or Strainer-mineral wool Nr 1.409 1.409 1.409 1.708 1.783 1.783 2.325 2.325 2.325Extra over Valve or Strainer-foamglass Nr 1.691 1.691 1.691 2.050 2.140 2.140 2.790 2.790 2.790Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.986 0.986 0.986 1.196 1.248 1.248 1.627 1.627 1.627Strip and remove to skip-Insulation and Cladding ft 0.102 0.102 0.102 0.123 0.129 0.129 0.168 0.168 0.168Extra over Elbow or Bend Nr 0.233 0.233 0.233 0.283 0.295 0.295 0.385 0.385 0.385Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.117 0.117 0.117 0.141 0.148 0.148 0.192 0.192 0.192Extra over Flange Joint-mineral wool or Foamglass Nr 0.333 0.333 0.333 0.404 0.422 0.422 0.550 0.550 0.550Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.500 0.500 0.500 0.606 0.633 0.633 0.825 0.825 0.825Strip and remove to skip-Cladding only ft 0.071 0.071 0.071 0.086 0.090 0.090 0.117 0.117 0.117Strip and store-Insulation and Cladding ft 0.141 0.141 0.141 0.171 0.179 0.179 0.233 0.233 0.233Strip and store-Cladding ft 0.099 0.099 0.099 0.120 0.125 0.125 0.163 0.163 0.163Strip, store and refit-Insulation and Cladding ft 0.317 0.317 0.317 0.384 0.401 0.401 0.523 0.523 0.523Strip, store and refit-Cladding ft 0.222 0.222 0.222 0.269 0.281 0.281 0.366 0.366 0.366Strip, store and refit-Cladding;remove and renew Insulation ft 0.308 0.308 0.308 0.373 0.389 0.389 0.508 0.508 0.508Extra over Elbow or Bend Nr 0.706 0.706 0.706 0.856 0.894 0.894 1.165 1.165 1.165Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.353 0.353 0.353 0.428 0.447 0.447 0.583 0.583 0.583Extra over Flange Joint-mineral wool Nr 1.009 1.009 1.009 1.223 1.277 1.277 1.665 1.665 1.665Extra over Valve or Strainer-mineral wool Nr 1.514 1.514 1.514 1.835 1.916 1.916 2.497 2.497 2.497Strip, remove and renew Cladding only ft 0.200 0.200 0.200 0.243 0.254 0.254 0.331 0.331 0.331
18" pipe size Unit 2 1/2" 3" 4" 4 1/2" 5" 5 1/2" 6"Insulation Thickness
1" 1 1/2" 2"
142
MINERAL WOOL PREFORMED SECTION: UP TO 24 MIL ALUZIN C OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.185 0.185 0.185 0.224 0.234 0.234 0.290 0.290 0.290Extra over Elbow or Bend Nr 0.424 0.424 0.424 0.514 0.537 0.537 0.667 0.667 0.667Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.212 0.212 0.212 0.257 0.268 0.268 0.333 0.333 0.333Extra over Flange Joint-mineral wool Nr 0.606 0.606 0.606 0.735 0.767 0.767 0.952 0.952 0.952Extra over Flange Joint-foamglass Nr 0.727 0.727 0.727 0.882 0.920 0.920 1.143 1.143 1.143Extra over Valve or Strainer-mineral wool Nr 0.909 0.909 0.909 1.102 1.151 1.151 1.429 1.429 1.429Extra over Valve or Strainer-foamglass Nr 1.091 1.091 1.091 1.322 1.381 1.381 1.714 1.714 1.714Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.636 0.636 0.636 0.771 0.805 0.805 1.000 1.000 1.000Strip, remove and renew complete specification ft 0.286 0.286 0.286 0.347 0.362 0.362 0.450 0.450 0.450Extra over Elbow or Bend Nr 0.658 0.658 0.658 0.797 0.832 0.832 1.033 1.033 1.033Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.329 0.329 0.329 0.399 0.416 0.416 0.517 0.517 0.517Extra over Flange Joint-mineral wool Nr 0.939 0.939 0.939 1.139 1.189 1.189 1.476 1.476 1.476Extra over Flange Joint-foamglass Nr 1.127 1.127 1.127 1.366 1.427 1.427 1.771 1.771 1.771Extra over Valve or Strainer-mineral wool Nr 1.409 1.409 1.409 1.708 1.783 1.783 2.214 2.214 2.214Extra over Valve or Strainer-foamglass Nr 1.691 1.691 1.691 2.050 2.140 2.140 2.657 2.657 2.657Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.986 0.986 0.986 1.196 1.248 1.248 1.550 1.550 1.550Strip and remove to skip-Insulation and Cladding ft 0.102 0.102 0.102 0.123 0.129 0.129 0.160 0.160 0.160Extra over Elbow or Bend Nr 0.233 0.233 0.233 0.283 0.295 0.295 0.367 0.367 0.367Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.117 0.117 0.117 0.141 0.148 0.148 0.183 0.183 0.183Extra over Flange Joint-mineral wool or Foamglass Nr 0.333 0.333 0.333 0.404 0.422 0.422 0.524 0.524 0.524Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.500 0.500 0.500 0.606 0.633 0.633 0.786 0.786 0.786Strip and remove to skip-Cladding only ft 0.071 0.071 0.071 0.086 0.090 0.090 0.112 0.112 0.112Strip and store-Insulation and Cladding ft 0.141 0.141 0.141 0.171 0.179 0.179 0.222 0.222 0.222Strip and store-Cladding ft 0.099 0.099 0.099 0.120 0.125 0.125 0.155 0.155 0.155Strip, store and refit-Insulation and Cladding ft 0.317 0.317 0.317 0.384 0.401 0.401 0.498 0.498 0.498Strip, store and refit-Cladding ft 0.222 0.222 0.222 0.269 0.281 0.281 0.348 0.348 0.348Strip, store and refit-Cladding;remove and renew Insulation ft 0.308 0.308 0.308 0.373 0.389 0.389 0.483 0.483 0.483Extra over Elbow or Bend Nr 0.706 0.706 0.706 0.856 0.894 0.894 1.110 1.110 1.110Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.353 0.353 0.353 0.428 0.447 0.447 0.555 0.555 0.555Extra over Flange Joint-mineral wool Nr 1.009 1.009 1.009 1.223 1.277 1.277 1.586 1.586 1.586Extra over Valve or Strainer-mineral wool Nr 1.514 1.514 1.514 1.835 1.916 1.916 2.378 2.378 2.378Strip, remove and renew Cladding only ft 0.200 0.200 0.200 0.243 0.254 0.254 0.315 0.315 0.315Extra over Elbow or Bend Nr 0.583Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.291
20" pipe size Unit 1" 1 1/2" 2" 2 1/2" 5 1/2" 6"3" 4" 4 1/2" 5"Insulation Thickness
143
L.2.2. Polyisocyanurate Preformed Sections: Vapour Seal (Mastic & Scrim Cloth) POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth)
n.e. 50mm Insulation Thickness Unit
Norm Norm Norm Norm NormNew Complete Specification m 0.614 0.768 1.001 1.348 1.841
Extra over Elbow or Bend Nr 0.430 0.537 0.701 0.944 1.289
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.215 0.268 0.350 0.472 0.644
Extra over Flange Joint Nr 0.614 0.767 1.001 1.348 1.841
Extra over Valve or Strainer Nr 0.920 1.151 1.501 2.022 2.761
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.644 0.805 1.051 1.416 1.933
Strip and remove to skip-Insulation and Coverings m 0.338 0.423 0.551 0.741 1.014
Extra over Elbow or Bend Nr 0.236 0.295 0.385 0.519 0.709
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.118 0.148 0.193 0.260 0.354
Extra over Flange Joint Nr 0.337 0.422 0.551 0.742 1.012
Extra over Valve or Strainer Nr 0.506 0.633 0.826 1.112 1.519
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.354 0.443 0.578 0.779 1.063
Strip, remove and renew complete specification m 0.951 1.188 1.552 2.090 2.854
Extra over Elbow or Bend Nr 0.666 0.832 1.086 1.463 1.997
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.333 0.416 0.543 0.731 0.999
Extra over Flange Joint Nr 0.951 1.189 1.551 2.090 2.853
Extra over Valve or Strainer Nr 1.427 1.783 2.327 3.135 4.280
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.999 1.248 1.629 2.194 2.996
n.e. 50mm Over 50mm n.e. 150mm
Over 150mm n.e. 250mm
Over 350mm n.e. 500mm
Over 250mm n.e. 350mm
UP TO 0.7mm ALUZINC, ALUMINIUM OR STAINLESS STEEL F LAT ROLLED CASING TO PIPEWORK (Low Temperature Service)
Pipe Size
144
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth)
n.e. 50mm Insulation Thickness Unit
Norm Norm Norm Norm NormNew Complete Specification m 2.403 2.602 2.803 3.002 3.203Extra over Elbow or Bend Nr 1.682 1.822 1.962 2.101 2.242Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.841 0.911 0.981 1.051 1.121Extra over Flange Joint Nr 2.403 2.602 2.803 3.002 3.203Extra over Valve or Strainer Nr 3.604 3.903 4.204 4.503 4.804Extra over Seal Closure Plate with Armourset and Rockwrap Nr 2.523 2.732 2.943 3.152 3.363
UP TO 0.7mm ALUZINC, ALUMINIUM OR STAINLESS STEEL F LAT ROLLED CASING TO PIPEWORK
Pipe SizeOver 500mm n.e. 600mm
650mm 700mm 750mm 800mm
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth)
n.e. 50mm Insulation Thickness UnitNorm Norm Norm Norm Norm
New Complete Specification m 3.603 4.205 4.806 5.407 6.007Extra over Elbow or Bend Nr 2.522 2.943 3.364 3.785 4.205Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 1.261 1.472 1.682 1.892 2.102Extra over Flange Joint Nr 3.603 4.205 4.806 5.407 6.007Extra over Valve or Strainer Nr 5.405 6.307 7.209 8.110 9.011Extra over Seal Closure Plate with Armourset and Rockwrap Nr 3.783 4.415 5.047 5.677 6.307
UP TO 0.7mm ALUZINC, ALUMINIUM OR STAINLESS STEEL F LAT ROLLED CASING TO PIPEWORK
Pipe Size900mm 1100mm 1200mm 1400mm 1500mm
145
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth)
Over 50mm n.e. 100mm Insulation Thickness Unit
Norm Norm Norm Norm NormNew Complete Specification m 0.935 1.122 1.447 1.923 2.526
Extra over Elbow or Bend Nr 0.655 0.786 1.011 1.345 1.769
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.328 0.393 0.506 0.673 0.884
Extra over Flange Joint Nr 0.936 1.122 1.445 1.922 2.527
Extra over Valve or Strainer Nr 1.404 1.684 2.167 2.883 3.790
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.983 1.179 1.517 2.018 2.653
Strip and remove to skip-Insulation and Coverings m 0.515 0.617 0.794 1.056 1.391
Extra over Elbow or Bend Nr 0.360 0.432 0.556 0.740 0.973
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.180 0.216 0.278 0.370 0.486
Extra over Flange Joint Nr 0.515 0.617 0.795 1.057 1.390
Extra over Valve or Strainer Nr 0.772 0.926 1.192 1.586 2.085
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.541 0.648 0.834 1.110 1.459
Strip, remove and renew complete specification m 1.450 1.739 2.241 2.979 3.917
Extra over Elbow or Bend Nr 1.016 1.218 1.568 2.085 2.742
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.508 0.609 0.784 1.043 1.371
Extra over Flange Joint Nr 1.451 1.740 2.240 2.979 3.917
Extra over Valve or Strainer Nr 2.177 2.610 3.360 4.468 5.875
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.524 1.827 2.352 3.128 4.113
Over 150mm n.e. 250mm
Over 350mm n.e. 500mm
Over 250mm n.e. 350mm
UP TO 0.7mm ALUZINC, ALUMINIUM OR STAINLESS STEEL F LAT ROLLED CASING TO PIPEWORK (Low Temperature Service)
n.e. 50mm Over 50mm n.e. 150mm
Pipe Size
146
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth)
Over 50mm n.e. 100mm Insulation Thickness Unit
Norm Norm Norm Norm NormNew Complete Specification m 3.284 3.557 3.831 4.103 4.378Extra over Elbow or Bend Nr 2.299 2.490 2.682 2.872 3.064Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 1.150 1.245 1.341 1.436 1.532Extra over Flange Joint Nr 3.284 3.557 3.831 4.103 4.378Extra over Valve or Strainer Nr 4.927 5.336 5.746 6.154 6.567Extra over Seal Closure Plate with Armourset and Rockwrap Nr 3.449 3.735 4.023 4.308 4.597
UP TO 0.7mm ALUZINC, ALUMINIUM OR STAINLESS STEEL F LAT ROLLED CASING TO PIPEWORK
Pipe SizeOver 500mm n.e. 600mm
650mm 700mm 750mm 800mm
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth)
Over 50mm n.e. 100mm Insulation Thickness UnitNorm Norm Norm Norm Norm
New Complete Specification m 4.925 5.748 6.569 7.391 8.211Extra over Elbow or Bend Nr 3.448 4.023 4.599 5.173 5.748Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 1.724 2.012 2.299 2.587 2.874Extra over Flange Joint Nr 4.925 5.748 6.569 7.391 8.211Extra over Valve or Strainer Nr 7.388 8.621 9.854 11.086 12.317Extra over Seal Closure Plate with Armourset and Rockwrap Nr 5.171 6.035 6.898 7.760 8.622
UP TO 0.7mm ALUZINC, ALUMINIUM OR STAINLESS STEEL F LAT ROLLED CASING TO PIPEWORK
Pipe Size900mm 1100mm 1200mm 1400mm 1500mm
147
n.e. 50mm Insulation Thickness Unit
Norm Norm Norm Norm NormNew Complete Specification m 0.266 0.338 0.410 0.669 0.791
Extra over Elbow or Bend Nr 0.186 0.237 0.288 0.469 0.554
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.093 0.119 0.144 0.234 0.277
Extra over Flange Joint Nr 0.266 0.339 0.411 0.670 0.791
Extra over Valve or Strainer Nr 0.399 0.509 0.617 1.005 1.187
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.280 0.356 0.432 0.703 0.831
Strip and remove to skip-Insulation and Cladding m 0.148 0.187 0.226 0.367 0.436
Extra over Elbow or Bend Nr 0.103 0.131 0.158 0.258 0.305
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.051 0.065 0.079 0.129 0.152
Extra over Flange Joint Nr 0.146 0.187 0.226 0.368 0.435
Extra over Valve or Strainer Nr 0.220 0.280 0.339 0.553 0.653
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.154 0.196 0.237 0.387 0.457
Strip and remove to skip-Cladding only m 0.102 0.131 0.157 0.259 0.305
Strip and store-Insulation and Cladding m 0.203 0.259 0.315 0.512 0.607
Strip and store-Cladding m 0.141 0.180 0.220 0.358 0.423
Strip, store and refit-Insulation and Cladding m 0.456 0.581 0.705 1.148 1.358
Strip, store and refit-Cladding m 0.318 0.407 0.492 0.804 0.951
Strip, store and refit Cladding;remove and renew Insulation m 0.443 0.564 0.686 1.115 1.319
Extra over Elbow or Bend Nr 0.310 0.395 0.479 0.781 0.922
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.155 0.198 0.240 0.390 0.461
Extra over Flange Joint Nr 0.443 0.565 0.685 1.115 1.318
Extra over Valve or Strainer Nr 0.665 0.847 1.027 1.673 1.976
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.466 0.593 0.719 1.171 1.383
Strip, remove and renew Cladding only m 0.289 0.367 0.446 0.728 0.860
Strip, remove and renew Complete Specification m 0.413 0.525 0.636 1.040 1.227
Extra over Elbow or Bend Nr 0.289 0.368 0.446 0.727 0.859
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.144 0.184 0.223 0.363 0.429
Extra over Flange Joint Nr 0.413 0.526 0.637 1.038 1.227
Extra over Valve or Strainer Nr 0.619 0.789 0.956 1.557 1.840
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.433 0.552 0.669 1.090 1.288
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 0.7mm AL UZINC, ALUMINIUM OR STAINLESS STEEL FLAT ROLLED CASING TO PIPEWORK
Over 350mm n.e. 500mm
Pipe Size
Over 150mm n.e. 250mm
Over 250mm n.e. 350mm
Over 50mm n.e. 150mm
n.e. 50mm
148
n.e. 50mm Insulation Thickness Unit
Norm Norm Norm Norm NormNew Complete Specification m 0.950 1.028 1.108 1.186 1.266
Extra over Elbow or Bend Nr 0.665 0.720 0.775 0.830 0.886
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.332 0.360 0.388 0.415 0.443
Extra over Flange Joint Nr 0.950 1.028 1.109 1.186 1.266
Extra over Valve or Strainer Nr 1.424 1.543 1.661 1.779 1.899
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.997 1.080 1.163 1.246 1.329
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 0.7mm AL UZINC, ALUMINIUM
Pipe Size Over 500mm n.e. 600mm
650mm 700mm 750mm 800mm
n.e. 50mm Insulation Thickness UnitNorm Norm Norm Norm Norm
New Complete Specification m 1.424 1.662 1.899 2.137 2.374
Extra over Elbow or Bend Nr 0.997 1.163 1.330 1.496 1.662
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.498 0.582 0.665 0.748 0.831
Extra over Flange Joint Nr 1.424 1.662 1.899 2.137 2.374
Extra over Valve or Strainer Nr 2.136 2.493 2.849 3.205 3.561
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.495 1.745 1.994 2.244 2.493
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 0.7mm AL UZINC, ALUMINIUM
Pipe Size 900mm 1100mm 1200mm 1400mm 1500mm
149
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.170 0.170 0.170 0.271 0.271 0.271 0.271
Extra over Elbow or Bend Nr 0.390 0.390 0.390 0.622 0.622 0.622 0.622
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.195 0.195 0.195 0.311 0.311 0.311 0.311
Extra over Flange Joint Nr 0.557 0.557 0.557 0.888 0.888 0.888 0.888
Extra over Valve or Strainer Nr 0.835 0.835 0.835 1.332 1.332 1.332 1.332
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.585 0.585 0.585 0.932 0.932 0.932 0.932
Strip and remove to skip-Insulation and Coverings ft 0.093 0.093 0.093 0.149 0.149 0.149 0.149
Extra over Elbow or Bend Nr 0.214 0.214 0.214 0.342 0.342 0.342 0.342
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.107 0.107 0.107 0.171 0.171 0.171 0.171
Extra over Flange Joint Nr 0.306 0.306 0.306 0.488 0.488 0.488 0.488
Extra over Valve or Strainer Nr 0.459 0.459 0.459 0.733 0.733 0.733 0.733
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.322 0.322 0.322 0.513 0.513 0.513 0.513
Strip, remove and renew complete specification ft 0.263 0.263 0.263 0.420 0.420 0.420 0.420
Extra over Elbow or Bend Nr 0.604 0.604 0.604 0.964 0.964 0.964 0.964
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.302 0.302 0.302 0.482 0.482 0.482 0.482
Extra over Flange Joint Nr 0.863 0.863 0.863 1.376 1.376 1.376 1.376
Extra over Valve or Strainer Nr 1.295 1.295 1.295 2.065 2.065 2.065 2.065
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.906 0.906 0.906 1.445 1.445 1.445 1.445
Unit1/2" pipe sizeInsulation Thickness
4"1" 1 1/2" 2" 2 1/2" 3" 3 1/2"
150
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.175 0.175 0.175 0.276 0.276 0.276 0.276
Extra over Elbow or Bend Nr 0.401 0.401 0.401 0.633 0.633 0.633 0.633
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.201 0.201 0.201 0.316 0.316 0.316 0.316
Extra over Flange Joint Nr 0.573 0.573 0.573 0.904 0.904 0.904 0.904
Extra over Valve or Strainer Nr 0.860 0.860 0.860 1.356 1.356 1.356 1.356
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.602 0.602 0.602 0.949 0.949 0.949 0.949
Strip and remove to skip-Insulation and Coverings ft 0.096 0.096 0.096 0.152 0.152 0.152 0.152
Extra over Elbow or Bend Nr 0.221 0.221 0.221 0.348 0.348 0.348 0.348
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.110 0.110 0.110 0.174 0.174 0.174 0.174
Extra over Flange Joint Nr 0.315 0.315 0.315 0.497 0.497 0.497 0.497
Extra over Valve or Strainer Nr 0.473 0.473 0.473 0.746 0.746 0.746 0.746
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.331 0.331 0.331 0.522 0.522 0.522 0.522
Strip, remove and renew complete specification ft 0.271 0.271 0.271 0.427 0.427 0.427 0.427
Extra over Elbow or Bend Nr 0.622 0.622 0.622 0.981 0.981 0.981 0.981
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.311 0.311 0.311 0.491 0.491 0.491 0.491
Extra over Flange Joint Nr 0.888 0.888 0.888 1.402 1.402 1.402 1.402
Extra over Valve or Strainer Nr 1.333 1.333 1.333 2.102 2.102 2.102 2.102
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.933 0.933 0.933 1.472 1.472 1.472 1.472
3/4" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
151
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.180 0.180 0.180 0.278 0.278 0.278 0.278
Extra over Elbow or Bend Nr 0.413 0.413 0.413 0.639 0.639 0.639 0.639
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.206 0.206 0.206 0.319 0.319 0.319 0.319
Extra over Flange Joint Nr 0.589 0.589 0.589 0.912 0.912 0.912 0.912
Extra over Valve or Strainer Nr 0.884 0.884 0.884 1.369 1.369 1.369 1.369
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.619 0.619 0.619 0.958 0.958 0.958 0.958
Strip and remove to skip-Insulation and Coverings ft 0.099 0.099 0.099 0.153 0.153 0.153 0.153
Extra over Elbow or Bend Nr 0.227 0.227 0.227 0.351 0.351 0.351 0.351
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.113 0.113 0.113 0.176 0.176 0.176 0.176
Extra over Flange Joint Nr 0.324 0.324 0.324 0.502 0.502 0.502 0.502
Extra over Valve or Strainer Nr 0.486 0.486 0.486 0.753 0.753 0.753 0.753
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.340 0.340 0.340 0.527 0.527 0.527 0.527
Strip, remove and renew complete specification ft 0.278 0.278 0.278 0.431 0.431 0.431 0.431
Extra over Elbow or Bend Nr 0.639 0.639 0.639 0.990 0.990 0.990 0.990
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.320 0.320 0.320 0.495 0.495 0.495 0.495
Extra over Flange Joint Nr 0.913 0.913 0.913 1.414 1.414 1.414 1.414
Extra over Valve or Strainer Nr 1.370 1.370 1.370 2.121 2.121 2.121 2.121
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.959 0.959 0.959 1.485 1.485 1.485 1.485
Unit1" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
152
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.187 0.187 0.187 0.285 0.285 0.285 0.285
Extra over Elbow or Bend Nr 0.430 0.430 0.430 0.655 0.655 0.655 0.655
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.215 0.215 0.215 0.328 0.328 0.328 0.328
Extra over Flange Joint Nr 0.614 0.614 0.614 0.936 0.936 0.936 0.936
Extra over Valve or Strainer Nr 0.920 0.920 0.920 1.404 1.404 1.404 1.404
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.644 0.644 0.644 0.983 0.983 0.983 0.983
Strip and remove to skip-Insulation and Coverings ft 0.103 0.103 0.103 0.157 0.157 0.157 0.157
Extra over Elbow or Bend Nr 0.236 0.236 0.236 0.360 0.360 0.360 0.360
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.118 0.118 0.118 0.180 0.180 0.180 0.180
Extra over Flange Joint Nr 0.337 0.337 0.337 0.515 0.515 0.515 0.515
Extra over Valve or Strainer Nr 0.506 0.506 0.506 0.772 0.772 0.772 0.772
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.354 0.354 0.354 0.541 0.541 0.541 0.541
Strip, remove and renew complete specification ft 0.290 0.290 0.290 0.442 0.442 0.442 0.442
Extra over Elbow or Bend Nr 0.666 0.666 0.666 1.016 1.016 1.016 1.016
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.333 0.333 0.333 0.508 0.508 0.508 0.508
Extra over Flange Joint Nr 0.951 0.951 0.951 1.451 1.451 1.451 1.451
Extra over Valve or Strainer Nr 1.427 1.427 1.427 2.177 2.177 2.177 2.177
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.999 0.999 0.999 1.524 1.524 1.524 1.524
Unit1 1/2" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
153
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.192 0.192 0.192 0.293 0.293 0.293 0.293
Extra over Elbow or Bend Nr 0.441 0.441 0.441 0.672 0.672 0.672 0.672
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.220 0.220 0.220 0.336 0.336 0.336 0.336
Extra over Flange Joint Nr 0.630 0.630 0.630 0.960 0.960 0.960 0.960
Extra over Valve or Strainer Nr 0.945 0.945 0.945 1.441 1.441 1.441 1.441
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.661 0.661 0.661 1.008 1.008 1.008 1.008
Strip and remove to skip-Insulation and Coverings ft 0.106 0.106 0.106 0.161 0.161 0.161 0.161
Extra over Elbow or Bend Nr 0.242 0.242 0.242 0.370 0.370 0.370 0.370
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.121 0.121 0.121 0.185 0.185 0.185 0.185
Extra over Flange Joint Nr 0.346 0.346 0.346 0.528 0.528 0.528 0.528
Extra over Valve or Strainer Nr 0.520 0.520 0.520 0.792 0.792 0.792 0.792
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.364 0.364 0.364 0.555 0.555 0.555 0.555
Strip, remove and renew complete specification ft 0.298 0.298 0.298 0.454 0.454 0.454 0.454
Extra over Elbow or Bend Nr 0.683 0.683 0.683 1.042 1.042 1.042 1.042
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.342 0.342 0.342 0.521 0.521 0.521 0.521
Extra over Flange Joint Nr 0.976 0.976 0.976 1.489 1.489 1.489 1.489
Extra over Valve or Strainer Nr 1.464 1.464 1.464 2.233 2.233 2.233 2.233
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.025 1.025 1.025 1.563 1.563 1.563 1.563
Unit2" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
154
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.219 0.219 0.219 0.327 0.327 0.327 0.327
Extra over Elbow or Bend Nr 0.503 0.503 0.503 0.752 0.752 0.752 0.752
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.251 0.251 0.251 0.376 0.376 0.376 0.376
Extra over Flange Joint Nr 0.718 0.718 0.718 1.074 1.074 1.074 1.074
Extra over Valve or Strainer Nr 1.078 1.078 1.078 1.611 1.611 1.611 1.611
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.754 0.754 0.754 1.128 1.128 1.128 1.128
Strip and remove to skip-Insulation and Coverings ft 0.120 0.120 0.120 0.180 0.180 0.180 0.180
Extra over Elbow or Bend Nr 0.277 0.277 0.277 0.413 0.413 0.413 0.413
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.138 0.138 0.138 0.207 0.207 0.207 0.207
Extra over Flange Joint Nr 0.395 0.395 0.395 0.591 0.591 0.591 0.591
Extra over Valve or Strainer Nr 0.593 0.593 0.593 0.886 0.886 0.886 0.886
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.415 0.415 0.415 0.620 0.620 0.620 0.620
Strip, remove and renew complete specification ft 0.340 0.340 0.340 0.507 0.507 0.507 0.507
Extra over Elbow or Bend Nr 0.780 0.780 0.780 1.165 1.165 1.165 1.165
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.390 0.390 0.390 0.583 0.583 0.583 0.583
Extra over Flange Joint Nr 1.114 1.114 1.114 1.664 1.664 1.664 1.664
Extra over Valve or Strainer Nr 1.670 1.670 1.670 2.497 2.497 2.497 2.497
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.169 1.169 1.169 1.748 1.748 1.748 1.748
Unit3" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
155
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.234 0.234 0.234 0.342 0.342 0.342 0.342
Extra over Elbow or Bend Nr 0.537 0.537 0.537 0.786 0.786 0.786 0.786
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.268 0.268 0.268 0.393 0.393 0.393 0.393
Extra over Flange Joint Nr 0.767 0.767 0.767 1.122 1.122 1.122 1.122
Extra over Valve or Strainer Nr 1.151 1.151 1.151 1.684 1.684 1.684 1.684
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.805 0.805 0.805 1.179 1.179 1.179 1.179
Strip and remove to skip-Insulation and Coverings ft 0.129 0.129 0.129 0.188 0.188 0.188 0.188
Extra over Elbow or Bend Nr 0.295 0.295 0.295 0.432 0.432 0.432 0.432
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.148 0.148 0.148 0.216 0.216 0.216 0.216
Extra over Flange Joint Nr 0.422 0.422 0.422 0.617 0.617 0.617 0.617
Extra over Valve or Strainer Nr 0.633 0.633 0.633 0.926 0.926 0.926 0.926
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.443 0.443 0.443 0.648 0.648 0.648 0.648
Strip, remove and renew complete specification ft 0.362 0.362 0.362 0.530 0.530 0.530 0.530
Extra over Elbow or Bend Nr 0.832 0.832 0.832 1.218 1.218 1.218 1.218
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.416 0.416 0.416 0.609 0.609 0.609 0.609
Extra over Flange Joint Nr 1.189 1.189 1.189 1.740 1.740 1.740 1.740
Extra over Valve or Strainer Nr 1.783 1.783 1.783 2.610 2.610 2.610 2.610
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.248 1.248 1.248 1.827 1.827 1.827 1.827
Unit4" pipe size 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"Insulation Thickness
1"
156
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.263 0.263 0.263 0.369 0.369 0.369 0.369
Extra over Elbow or Bend Nr 0.605 0.605 0.605 0.848 0.848 0.848 0.848
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.302 0.302 0.302 0.424 0.424 0.424 0.424
Extra over Flange Joint Nr 0.864 0.864 0.864 1.211 1.211 1.211 1.211
Extra over Valve or Strainer Nr 1.296 1.296 1.296 1.817 1.817 1.817 1.817
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.907 0.907 0.907 1.272 1.272 1.272 1.272
Strip and remove to skip-Insulation and Coverings ft 0.145 0.145 0.145 0.203 0.203 0.203 0.203
Extra over Elbow or Bend Nr 0.333 0.333 0.333 0.466 0.466 0.466 0.466
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.166 0.166 0.166 0.233 0.233 0.233 0.233
Extra over Flange Joint Nr 0.475 0.475 0.475 0.666 0.666 0.666 0.666
Extra over Valve or Strainer Nr 0.713 0.713 0.713 0.999 0.999 0.999 0.999
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.499 0.499 0.499 0.699 0.699 0.699 0.699
Strip, remove and renew complete specification ft 0.408 0.408 0.408 0.572 0.572 0.572 0.572
Extra over Elbow or Bend Nr 0.937 0.937 0.937 1.314 1.314 1.314 1.314
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.469 0.469 0.469 0.657 0.657 0.657 0.657
Extra over Flange Joint Nr 1.339 1.339 1.339 1.877 1.877 1.877 1.877
Extra over Valve or Strainer Nr 2.008 2.008 2.008 2.816 2.816 2.816 2.816
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.406 1.406 1.406 1.971 1.971 1.971 1.971
Unit6" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
157
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.305 0.305 0.305 0.441 0.441 0.441 0.441
Extra over Elbow or Bend Nr 0.701 0.701 0.701 1.011 1.011 1.011 1.011
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.350 0.350 0.350 0.506 0.506 0.506 0.506
Extra over Flange Joint Nr 1.001 1.001 1.001 1.445 1.445 1.445 1.445
Extra over Valve or Strainer Nr 1.501 1.501 1.501 2.167 2.167 2.167 2.167
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.051 1.051 1.051 1.517 1.517 1.517 1.517
Strip and remove to skip-Insulation and Coverings ft 0.168 0.168 0.168 0.242 0.242 0.242 0.242
Extra over Elbow or Bend Nr 0.385 0.385 0.385 0.556 0.556 0.556 0.556
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.193 0.193 0.193 0.278 0.278 0.278 0.278
Extra over Flange Joint Nr 0.551 0.551 0.551 0.795 0.795 0.795 0.795
Extra over Valve or Strainer Nr 0.826 0.826 0.826 1.192 1.192 1.192 1.192
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.578 0.578 0.578 0.834 0.834 0.834 0.834
Strip, remove and renew complete specification ft 0.473 0.473 0.473 0.683 0.683 0.683 0.683
Extra over Elbow or Bend Nr 1.086 1.086 1.086 1.568 1.568 1.568 1.568
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.543 0.543 0.543 0.784 0.784 0.784 0.784
Extra over Flange Joint Nr 1.551 1.551 1.551 2.240 2.240 2.240 2.240
Extra over Valve or Strainer Nr 2.327 2.327 2.327 3.360 3.360 3.360 3.360
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.629 1.629 1.629 2.352 2.352 2.352 2.352
Unit8" pipe size 3 1/2" 4"Insulation Thickness
1" 1 1/2" 2" 2 1/2" 3"
158
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.337 0.337 0.337 0.473 0.473 0.473 0.473
Extra over Elbow or Bend Nr 0.774 0.774 0.774 1.085 1.085 1.085 1.085
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.387 0.387 0.387 0.543 0.543 0.543 0.543
Extra over Flange Joint Nr 1.106 1.106 1.106 1.550 1.550 1.550 1.550
Extra over Valve or Strainer Nr 1.659 1.659 1.659 2.325 2.325 2.325 2.325
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.162 1.162 1.162 1.628 1.628 1.628 1.628
Strip and remove to skip-Insulation and Coverings ft 0.186 0.186 0.186 0.260 0.260 0.260 0.260
Extra over Elbow or Bend Nr 0.426 0.426 0.426 0.597 0.597 0.597 0.597
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.213 0.213 0.213 0.298 0.298 0.298 0.298
Extra over Flange Joint Nr 0.608 0.608 0.608 0.853 0.853 0.853 0.853
Extra over Valve or Strainer Nr 0.913 0.913 0.913 1.279 1.279 1.279 1.279
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.639 0.639 0.639 0.895 0.895 0.895 0.895
Strip, remove and renew complete specification ft 0.523 0.523 0.523 0.733 0.733 0.733 0.733
Extra over Elbow or Bend Nr 1.200 1.200 1.200 1.682 1.682 1.682 1.682
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.600 0.600 0.600 0.841 0.841 0.841 0.841
Extra over Flange Joint Nr 1.715 1.715 1.715 2.403 2.403 2.403 2.403
Extra over Valve or Strainer Nr 2.572 2.572 2.572 3.604 3.604 3.604 3.604
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.800 1.800 1.800 2.523 2.523 2.523 2.523
10" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
159
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.411 0.411 0.411 0.586 0.586 0.586 0.586
Extra over Elbow or Bend Nr 0.944 0.944 0.944 1.345 1.345 1.345 1.345
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.472 0.472 0.472 0.673 0.673 0.673 0.673
Extra over Flange Joint Nr 1.348 1.348 1.348 1.922 1.922 1.922 1.922
Extra over Valve or Strainer Nr 2.022 2.022 2.022 2.883 2.883 2.883 2.883
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.416 1.416 1.416 2.018 2.018 2.018 2.018
Strip and remove to skip-Insulation and Coverings ft 0.226 0.226 0.226 0.322 0.322 0.322 0.322
Extra over Elbow or Bend Nr 0.519 0.519 0.519 0.740 0.740 0.740 0.740
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.260 0.260 0.260 0.370 0.370 0.370 0.370
Extra over Flange Joint Nr 0.742 0.742 0.742 1.057 1.057 1.057 1.057
Extra over Valve or Strainer Nr 1.112 1.112 1.112 1.586 1.586 1.586 1.586
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.779 0.779 0.779 1.110 1.110 1.110 1.110
Strip, remove and renew complete specification ft 0.637 0.637 0.637 0.908 0.908 0.908 0.908
Extra over Elbow or Bend Nr 1.463 1.463 1.463 2.085 2.085 2.085 2.085
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.731 0.731 0.731 1.043 1.043 1.043 1.043
Extra over Flange Joint Nr 2.090 2.090 2.090 2.979 2.979 2.979 2.979
Extra over Valve or Strainer Nr 3.135 3.135 3.135 4.468 4.468 4.468 4.468
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 2.194 2.194 2.194 3.128 3.128 3.128 3.128
Unit12" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
160
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.460 0.460 0.460 0.650 0.650 0.650 0.650
Extra over Elbow or Bend Nr 1.057 1.057 1.057 1.492 1.492 1.492 1.492
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.528 0.528 0.528 0.746 0.746 0.746 0.746
Extra over Flange Joint Nr 1.510 1.510 1.510 2.132 2.132 2.132 2.132
Extra over Valve or Strainer Nr 2.265 2.265 2.265 3.197 3.197 3.197 3.197
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.585 1.585 1.585 2.238 2.238 2.238 2.238
Strip and remove to skip-Insulation and Coverings ft 0.253 0.253 0.253 0.357 0.357 0.357 0.357
Extra over Elbow or Bend Nr 0.581 0.581 0.581 0.821 0.821 0.821 0.821
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.291 0.291 0.291 0.410 0.410 0.410 0.410
Extra over Flange Joint Nr 0.830 0.830 0.830 1.172 1.172 1.172 1.172
Extra over Valve or Strainer Nr 1.246 1.246 1.246 1.758 1.758 1.758 1.758
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.872 0.872 0.872 1.231 1.231 1.231 1.231
Strip, remove and renew complete specification ft 0.713 0.713 0.713 1.007 1.007 1.007 1.007
Extra over Elbow or Bend Nr 1.638 1.638 1.638 2.313 2.313 2.313 2.313
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.819 0.819 0.819 1.156 1.156 1.156 1.156
Extra over Flange Joint Nr 2.340 2.340 2.340 3.304 3.304 3.304 3.304
Extra over Valve or Strainer Nr 3.510 3.510 3.510 4.956 4.956 4.956 4.956
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 2.457 2.457 2.457 3.469 3.469 3.469 3.469
Unit14" pipe size 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"Insulation Thickness
1"
161
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.502 0.502 0.502 0.699 0.699 0.699 0.699
Extra over Elbow or Bend Nr 1.153 1.153 1.153 1.605 1.605 1.605 1.605
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.576 0.576 0.576 0.803 0.803 0.803 0.803
Extra over Flange Joint Nr 1.647 1.647 1.647 2.293 2.293 2.293 2.293
Extra over Valve or Strainer Nr 2.470 2.470 2.470 3.440 3.440 3.440 3.440
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.729 1.729 1.729 2.408 2.408 2.408 2.408
Strip and remove to skip-Insulation and Coverings ft 0.276 0.276 0.276 0.385 0.385 0.385 0.385
Extra over Elbow or Bend Nr 0.634 0.634 0.634 0.883 0.883 0.883 0.883
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.317 0.317 0.317 0.441 0.441 0.441 0.441
Extra over Flange Joint Nr 0.906 0.906 0.906 1.261 1.261 1.261 1.261
Extra over Valve or Strainer Nr 1.359 1.359 1.359 1.892 1.892 1.892 1.892
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.951 0.951 0.951 1.324 1.324 1.324 1.324
Strip, remove and renew complete specification ft 0.778 0.778 0.778 1.084 1.084 1.084 1.084
Extra over Elbow or Bend Nr 1.787 1.787 1.787 2.488 2.488 2.488 2.488
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.893 0.893 0.893 1.244 1.244 1.244 1.244
Extra over Flange Joint Nr 2.553 2.553 2.553 3.554 3.554 3.554 3.554
Extra over Valve or Strainer Nr 3.829 3.829 3.829 5.331 5.331 5.331 5.331
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 2.680 2.680 2.680 3.732 3.732 3.732 3.732
Unit16" pipe size 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"Insulation Thickness
1"
162
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.561 0.561 0.561 0.770 0.770 0.770 0.770
Extra over Elbow or Bend Nr 1.289 1.289 1.289 1.769 1.769 1.769 1.769
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.644 0.644 0.644 0.884 0.884 0.884 0.884
Extra over Flange Joint Nr 1.841 1.841 1.841 2.527 2.527 2.527 2.527
Extra over Valve or Strainer Nr 2.761 2.761 2.761 3.790 3.790 3.790 3.790
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.933 1.933 1.933 2.653 2.653 2.653 2.653
Strip and remove to skip-Insulation and Coverings ft 0.309 0.309 0.309 0.424 0.424 0.424 0.424
Extra over Elbow or Bend Nr 0.709 0.709 0.709 0.973 0.973 0.973 0.973
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.354 0.354 0.354 0.486 0.486 0.486 0.486
Extra over Flange Joint Nr 1.012 1.012 1.012 1.390 1.390 1.390 1.390
Extra over Valve or Strainer Nr 1.519 1.519 1.519 2.085 2.085 2.085 2.085
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.063 1.063 1.063 1.459 1.459 1.459 1.459
Strip, remove and renew complete specification ft 0.870 0.870 0.870 1.194 1.194 1.194 1.194
Extra over Elbow or Bend Nr 1.997 1.997 1.997 2.742 2.742 2.742 2.742
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.999 0.999 0.999 1.371 1.371 1.371 1.371
Extra over Flange Joint Nr 2.853 2.853 2.853 3.917 3.917 3.917 3.917
Extra over Valve or Strainer Nr 4.280 4.280 4.280 5.875 5.875 5.875 5.875
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 2.996 2.996 2.996 4.113 4.113 4.113 4.113
18" pipe size Unit 3 1/2" 4"1 1/2" 2" 2 1/2" 3"Insulation Thickness
1"
163
POLYISOCYANURATE PREFORMED SECTIONS: VAPOUR SEAL (M astic and Scrim Cloth) UP TO 24 MIL ALUZINC OR ALUMINIUM FLAT ROLLED CASIN G TO PIPEWORK (Low Temperature Service)
Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.610 0.518 0.610 0.834 0.834 0.834 0.834
Extra over Elbow or Bend Nr 1.402 1.189 1.402 1.916 1.916 1.916 1.916
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.701 0.595 0.701 0.958 0.958 0.958 0.958
Extra over Flange Joint Nr 2.002 1.699 2.002 2.737 2.737 2.737 2.737
Extra over Valve or Strainer Nr 3.004 2.548 3.004 4.106 4.106 4.106 4.106
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 2.103 1.784 2.103 2.874 2.874 2.874 2.874
Strip and remove to skip-Insulation and Coverings ft 0.336 0.285 0.336 0.459 0.459 0.459 0.459
Extra over Elbow or Bend Nr 0.771 0.654 0.771 1.054 1.054 1.054 1.054
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.385 0.327 0.385 0.527 0.527 0.527 0.527
Extra over Flange Joint Nr 1.101 0.934 1.101 1.505 1.505 1.505 1.505
Extra over Valve or Strainer Nr 1.652 1.401 1.652 2.258 2.258 2.258 2.258
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.156 0.981 1.156 1.581 1.581 1.581 1.581
Strip, remove and renew complete specification ft 0.946 0.803 0.946 1.293 1.293 1.293 1.293
Extra over Elbow or Bend Nr 2.173 1.843 2.173 2.970 2.970 2.970 2.970
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 1.086 0.922 1.086 1.485 1.485 1.485 1.485
Extra over Flange Joint Nr 3.104 2.633 3.104 4.242 4.242 4.242 4.242
Extra over Valve or Strainer Nr 4.656 3.949 4.656 6.364 6.364 6.364 6.364
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 3.259 2.765 3.259 4.455 4.455 4.455 4.455
Unit20" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
164
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.081 0.081 0.081
Extra over Elbow or Bend Nr 0.186 0.186 0.186
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.093 0.093 0.093
Extra over Flange Joint Nr 0.266 0.266 0.266
Extra over Valve or Strainer Nr 0.399 0.399 0.399
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.280 0.280 0.280
Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045
Extra over Elbow or Bend Nr 0.103 0.103 0.103
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.051 0.051 0.051
Extra over Flange Joint Nr 0.146 0.146 0.146
Extra over Valve or Strainer Nr 0.220 0.220 0.220
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.154 0.154 0.154
Strip and remove to skip-Cladding only ft 0.031 0.031 0.031
Strip and store-Insulation and Cladding ft 0.062 0.062 0.062
Strip and store-Cladding ft 0.043 0.043 0.043
Strip, store and refit-Insulation and Cladding ft 0.139 0.139 0.139
Strip, store and refit-Cladding ft 0.097 0.097 0.097
Strip, store and refit Cladding;remove and renew Insulation ft 0.135 0.135 0.135
Extra over Elbow or Bend Nr 0.310 0.310 0.310
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.155 0.155 0.155
Extra over Flange Joint Nr 0.443 0.443 0.443
Extra over Valve or Strainer Nr 0.665 0.665 0.665
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.466 0.466 0.466
Strip, remove and renew Cladding only ft 0.088 0.088 0.088
Strip, remove and renew Complete Specification ft 0.126 0.126 0.126
Extra over Elbow or Bend Nr 0.289 0.289 0.289
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.144 0.144 0.144
Extra over Flange Joint Nr 0.413 0.413 0.413
Extra over Valve or Strainer Nr 0.619 0.619 0.619
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.433 0.433 0.433
Unit1/2" pipe sizeInsulation Thickness1" 1 1/2" 2"
165
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.081 0.081 0.081
Extra over Elbow or Bend Nr 0.186 0.186 0.186
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.093 0.093 0.093
Extra over Flange Joint Nr 0.266 0.266 0.266
Extra over Valve or Strainer Nr 0.399 0.399 0.399
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.280 0.280 0.280
Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045
Extra over Elbow or Bend Nr 0.103 0.103 0.103
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.051 0.051 0.051
Extra over Flange Joint Nr 0.146 0.146 0.146
Extra over Valve or Strainer Nr 0.220 0.220 0.220
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.154 0.154 0.154
Strip and remove to skip-Cladding only ft 0.031 0.031 0.031
Strip and store-Insulation and Cladding ft 0.062 0.062 0.062
Strip and store-Cladding ft 0.043 0.043 0.043
Strip, store and refit-Insulation and Cladding ft 0.139 0.139 0.139
Strip, store and refit-Cladding ft 0.097 0.097 0.097
Strip, store and refit Cladding;remove and renew Insulation ft 0.135 0.135 0.135
Extra over Elbow or Bend Nr 0.310 0.310 0.310
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.155 0.155 0.155
Extra over Flange Joint Nr 0.443 0.443 0.443
Extra over Valve or Strainer Nr 0.665 0.665 0.665
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.466 0.466 0.466
Strip, remove and renew Cladding only ft 0.088 0.088 0.088
Strip, remove and renew Complete Specification ft 0.126 0.126 0.126
Extra over Elbow or Bend Nr 0.289 0.289 0.289
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.144 0.144 0.144
Extra over Flange Joint Nr 0.413 0.413 0.413
Extra over Valve or Strainer Nr 0.619 0.619 0.619
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.433 0.433 0.433
Unit3/4" pipe sizeInsulation Thickness1" 1 1/2" 2"
166
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.081 0.081 0.081
Extra over Elbow or Bend Nr 0.186 0.186 0.186
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.093 0.093 0.093
Extra over Flange Joint Nr 0.266 0.266 0.266
Extra over Valve or Strainer Nr 0.399 0.399 0.399
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.280 0.280 0.280
Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045
Extra over Elbow or Bend Nr 0.103 0.103 0.103
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.051 0.051 0.051
Extra over Flange Joint Nr 0.146 0.146 0.146
Extra over Valve or Strainer Nr 0.220 0.220 0.220
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.154 0.154 0.154
Strip and remove to skip-Cladding only ft 0.031 0.031 0.031
Strip and store-Insulation and Cladding ft 0.062 0.062 0.062
Strip and store-Cladding ft 0.043 0.043 0.043
Strip, store and refit-Insulation and Cladding ft 0.139 0.139 0.139
Strip, store and refit-Cladding ft 0.097 0.097 0.097
Strip, store and refit Cladding;remove and renew Insulation ft 0.135 0.135 0.135
Extra over Elbow or Bend Nr 0.310 0.310 0.310
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.155 0.155 0.155
Extra over Flange Joint Nr 0.443 0.443 0.443
Extra over Valve or Strainer Nr 0.665 0.665 0.665
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.466 0.466 0.466
Strip, remove and renew Cladding only ft 0.088 0.088 0.088
Strip, remove and renew Complete Specification ft 0.126 0.126 0.126
Extra over Elbow or Bend Nr 0.289 0.289 0.289
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.144 0.144 0.144
Extra over Flange Joint Nr 0.413 0.413 0.413
Extra over Valve or Strainer Nr 0.619 0.619 0.619
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.433 0.433 0.433
Unit1" pipe sizeInsulation Thickness1" 1 1/2" 2"
167
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.081 0.081 0.081
Extra over Elbow or Bend Nr 0.186 0.186 0.186
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.093 0.093 0.093
Extra over Flange Joint Nr 0.266 0.266 0.266
Extra over Valve or Strainer Nr 0.399 0.399 0.399
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.280 0.280 0.280
Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045
Extra over Elbow or Bend Nr 0.103 0.103 0.103
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.051 0.051 0.051
Extra over Flange Joint Nr 0.146 0.146 0.146
Extra over Valve or Strainer Nr 0.220 0.220 0.220
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.154 0.154 0.154
Strip and remove to skip-Cladding only ft 0.031 0.031 0.031
Strip and store-Insulation and Cladding ft 0.062 0.062 0.062
Strip and store-Cladding ft 0.043 0.043 0.043
Strip, store and refit-Insulation and Cladding ft 0.139 0.139 0.139
Strip, store and refit-Cladding ft 0.097 0.097 0.097
Strip, store and refit Cladding;remove and renew Insulation ft 0.135 0.135 0.135
Extra over Elbow or Bend Nr 0.310 0.310 0.310
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.155 0.155 0.155
Extra over Flange Joint Nr 0.443 0.443 0.443
Extra over Valve or Strainer Nr 0.665 0.665 0.665
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.466 0.466 0.466
Strip, remove and renew Cladding only ft 0.088 0.088 0.088
Strip, remove and renew Complete Specification ft 0.126 0.126 0.126
Extra over Elbow or Bend Nr 0.289 0.289 0.289
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.144 0.144 0.144
Extra over Flange Joint Nr 0.413 0.413 0.413
Extra over Valve or Strainer Nr 0.619 0.619 0.619
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.433 0.433 0.433
1 1/2" pipe size Unit 1 1/2" 2"Insulation Thickness1"
168
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.081 0.081 0.081
Extra over Elbow or Bend Nr 0.186 0.186 0.186
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.093 0.093 0.093
Extra over Flange Joint Nr 0.266 0.266 0.266
Extra over Valve or Strainer Nr 0.399 0.399 0.399
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.280 0.280 0.280
Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045
Extra over Elbow or Bend Nr 0.103 0.103 0.103
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.051 0.051 0.051
Extra over Flange Joint Nr 0.146 0.146 0.146
Extra over Valve or Strainer Nr 0.220 0.220 0.220
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.154 0.154 0.154
Strip and remove to skip-Cladding only ft 0.031 0.031 0.031
Strip and store-Insulation and Cladding ft 0.062 0.062 0.062
Strip and store-Cladding ft 0.043 0.043 0.043
Strip, store and refit-Insulation and Cladding ft 0.139 0.139 0.139
Strip, store and refit-Cladding ft 0.097 0.097 0.097
Strip, store and refit Cladding;remove and renew Insulation ft 0.135 0.135 0.135
Extra over Elbow or Bend Nr 0.310 0.310 0.310
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.155 0.155 0.155
Extra over Flange Joint Nr 0.443 0.443 0.443
Extra over Valve or Strainer Nr 0.665 0.665 0.665
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.466 0.466 0.466
Strip, remove and renew Cladding only ft 0.088 0.088 0.088
Strip, remove and renew Complete Specification ft 0.126 0.126 0.126
Extra over Elbow or Bend Nr 0.289 0.289 0.289
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.144 0.144 0.144
Extra over Flange Joint Nr 0.413 0.413 0.413
Extra over Valve or Strainer Nr 0.619 0.619 0.619
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.433 0.433 0.433
Unit2" pipe sizeInsulation Thickness1" 1 1/2" 2"
169
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.103 0.103 0.103
Extra over Elbow or Bend Nr 0.237 0.237 0.237
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.119 0.119 0.119
Extra over Flange Joint Nr 0.339 0.339 0.339
Extra over Valve or Strainer Nr 0.509 0.509 0.509
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.356 0.356 0.356
Strip and remove to skip-Insulation and Cladding ft 0.057 0.057 0.057
Extra over Elbow or Bend Nr 0.131 0.131 0.131
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.065 0.065 0.065
Extra over Flange Joint Nr 0.187 0.187 0.187
Extra over Valve or Strainer Nr 0.280 0.280 0.280
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.196 0.196 0.196
Strip and remove to skip-Cladding only ft 0.040 0.040 0.040
Strip and store-Insulation and Cladding ft 0.079 0.079 0.079
Strip and store-Cladding ft 0.055 0.055 0.055
Strip, store and refit-Insulation and Cladding ft 0.177 0.177 0.177
Strip, store and refit-Cladding ft 0.124 0.124 0.124
Strip, store and refit Cladding;remove and renew Insulation ft 0.172 0.172 0.172
Extra over Elbow or Bend Nr 0.395 0.395 0.395
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.198 0.198 0.198
Extra over Flange Joint Nr 0.565 0.565 0.565
Extra over Valve or Strainer Nr 0.847 0.847 0.847
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.593 0.593 0.593
Strip, remove and renew Cladding only ft 0.112 0.112 0.112
Strip, remove and renew Complete Specification ft 0.160 0.160 0.160
Extra over Elbow or Bend Nr 0.368 0.368 0.368
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.184 0.184 0.184
Extra over Flange Joint Nr 0.526 0.526 0.526
Extra over Valve or Strainer Nr 0.789 0.789 0.789
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.552 0.552 0.552
Unit3" pipe sizeInsulation Thickness1" 1 1/2" 2"
170
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.103 0.103 0.103
Extra over Elbow or Bend Nr 0.237 0.237 0.237
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.119 0.119 0.119
Extra over Flange Joint Nr 0.339 0.339 0.339
Extra over Valve or Strainer Nr 0.509 0.509 0.509
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.356 0.356 0.356
Strip and remove to skip-Insulation and Cladding ft 0.057 0.057 0.057
Extra over Elbow or Bend Nr 0.131 0.131 0.131
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.065 0.065 0.065
Extra over Flange Joint Nr 0.187 0.187 0.187
Extra over Valve or Strainer Nr 0.280 0.280 0.280
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.196 0.196 0.196
Strip and remove to skip-Cladding only ft 0.040 0.040 0.040
Strip and store-Insulation and Cladding ft 0.079 0.079 0.079
Strip and store-Cladding ft 0.055 0.055 0.055
Strip, store and refit-Insulation and Cladding ft 0.177 0.177 0.177
Strip, store and refit-Cladding ft 0.124 0.124 0.124
Strip, store and refit Cladding;remove and renew Insulation ft 0.172 0.172 0.172
Extra over Elbow or Bend Nr 0.395 0.395 0.395
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.198 0.198 0.198
Extra over Flange Joint Nr 0.565 0.565 0.565
Extra over Valve or Strainer Nr 0.847 0.847 0.847
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.593 0.593 0.593
Strip, remove and renew Cladding only ft 0.112 0.112 0.112
Strip, remove and renew Complete Specification ft 0.160 0.160 0.160
Extra over Elbow or Bend Nr 0.368 0.368 0.368
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.184 0.184 0.184
Extra over Flange Joint Nr 0.526 0.526 0.526
Extra over Valve or Strainer Nr 0.789 0.789 0.789
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.552 0.552 0.552
4" pipe size UnitInsulation Thickness1" 1 1/2" 2"
171
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.103 0.103 0.103
Extra over Elbow or Bend Nr 0.237 0.237 0.237
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.119 0.119 0.119
Extra over Flange Joint Nr 0.339 0.339 0.339
Extra over Valve or Strainer Nr 0.509 0.509 0.509
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.356 0.356 0.356
Strip and remove to skip-Insulation and Cladding ft 0.057 0.057 0.057
Extra over Elbow or Bend Nr 0.131 0.131 0.131
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.065 0.065 0.065
Extra over Flange Joint Nr 0.187 0.187 0.187
Extra over Valve or Strainer Nr 0.280 0.280 0.280
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.196 0.196 0.196
Strip and remove to skip-Cladding only ft 0.040 0.040 0.040
Strip and store-Insulation and Cladding ft 0.079 0.079 0.079
Strip and store-Cladding ft 0.055 0.055 0.055
Strip, store and refit-Insulation and Cladding ft 0.177 0.177 0.177
Strip, store and refit-Cladding ft 0.124 0.124 0.124
Strip, store and refit Cladding;remove and renew Insulation ft 0.172 0.172 0.172
Extra over Elbow or Bend Nr 0.395 0.395 0.395
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.198 0.198 0.198
Extra over Flange Joint Nr 0.565 0.565 0.565
Extra over Valve or Strainer Nr 0.847 0.847 0.847
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.593 0.593 0.593
Strip, remove and renew Cladding only ft 0.112 0.112 0.112
Strip, remove and renew Complete Specification ft 0.160 0.160 0.160
Extra over Elbow or Bend Nr 0.368 0.368 0.368
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.184 0.184 0.184
Extra over Flange Joint Nr 0.526 0.526 0.526
Extra over Valve or Strainer Nr 0.789 0.789 0.789
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.552 0.552 0.552
Unit6" pipe sizeInsulation Thickness1" 1 1/2" 2"
172
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.125 0.125 0.125
Extra over Elbow or Bend Nr 0.288 0.288 0.288
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.144 0.144 0.144
Extra over Flange Joint Nr 0.411 0.411 0.411
Extra over Valve or Strainer Nr 0.617 0.617 0.617
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.432 0.432 0.432
Strip and remove to skip-Insulation and Cladding ft 0.069 0.069 0.069
Extra over Elbow or Bend Nr 0.158 0.158 0.158
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.079 0.079 0.079
Extra over Flange Joint Nr 0.226 0.226 0.226
Extra over Valve or Strainer Nr 0.339 0.339 0.339
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.237 0.237 0.237
Strip and remove to skip-Cladding only ft 0.048 0.048 0.048
Strip and store-Insulation and Cladding ft 0.096 0.096 0.096
Strip and store-Cladding ft 0.067 0.067 0.067
Strip, store and refit-Insulation and Cladding ft 0.215 0.215 0.215
Strip, store and refit-Cladding ft 0.150 0.150 0.150
Strip, store and refit Cladding;remove and renew Insulation ft 0.209 0.209 0.209
Extra over Elbow or Bend Nr 0.479 0.479 0.479
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.240 0.240 0.240
Extra over Flange Joint Nr 0.685 0.685 0.685
Extra over Valve or Strainer Nr 1.027 1.027 1.027
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.719 0.719 0.719
Strip, remove and renew Cladding only ft 0.136 0.136 0.136
Strip, remove and renew Complete Specification ft 0.194 0.194 0.194
Extra over Elbow or Bend Nr 0.446 0.446 0.446
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.223 0.223 0.223
Extra over Flange Joint Nr 0.637 0.637 0.637
Extra over Valve or Strainer Nr 0.956 0.956 0.956
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.669 0.669 0.669
Unit8" pipe sizeInsulation Thickness1" 1 1/2" 2"
173
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.125 0.125 0.125
Extra over Elbow or Bend Nr 0.288 0.288 0.288
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.144 0.144 0.144
Extra over Flange Joint Nr 0.411 0.411 0.411
Extra over Valve or Strainer Nr 0.617 0.617 0.617
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.432 0.432 0.432
Strip and remove to skip-Insulation and Cladding ft 0.069 0.069 0.069
Extra over Elbow or Bend Nr 0.158 0.158 0.158
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.079 0.079 0.079
Extra over Flange Joint Nr 0.226 0.226 0.226
Extra over Valve or Strainer Nr 0.339 0.339 0.339
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.237 0.237 0.237
Strip and remove to skip-Cladding only ft 0.048 0.048 0.048
Strip and store-Insulation and Cladding ft 0.096 0.096 0.096
Strip and store-Cladding ft 0.067 0.067 0.067
Strip, store and refit-Insulation and Cladding ft 0.215 0.215 0.215
Strip, store and refit-Cladding ft 0.150 0.150 0.150
Strip, store and refit Cladding;remove and renew Insulation ft 0.209 0.209 0.209
Extra over Elbow or Bend Nr 0.479 0.479 0.479
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.240 0.240 0.240
Extra over Flange Joint Nr 0.685 0.685 0.685
Extra over Valve or Strainer Nr 1.027 1.027 1.027
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.719 0.719 0.719
Strip, remove and renew Cladding only ft 0.136 0.136 0.136
Strip, remove and renew Complete Specification ft 0.194 0.194 0.194
Extra over Elbow or Bend Nr 0.446 0.446 0.446
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.223 0.223 0.223
Extra over Flange Joint Nr 0.637 0.637 0.637
Extra over Valve or Strainer Nr 0.956 0.956 0.956
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.669 0.669 0.669
10" pipe size UnitInsulation Thickness1" 1 1/2" 2"
174
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.162 0.162 0.162
Extra over Elbow or Bend Nr 0.373 0.373 0.373
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.186 0.186 0.186
Extra over Flange Joint Nr 0.533 0.533 0.533
Extra over Valve or Strainer Nr 0.799 0.799 0.799
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.559 0.559 0.559
Strip and remove to skip-Insulation and Cladding ft 0.089 0.089 0.089
Extra over Elbow or Bend Nr 0.205 0.205 0.205
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.103 0.103 0.103
Extra over Flange Joint Nr 0.293 0.293 0.293
Extra over Valve or Strainer Nr 0.439 0.439 0.439
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.308 0.308 0.308
Strip and remove to skip-Cladding only ft 0.063 0.063 0.063
Strip and store-Insulation and Cladding ft 0.124 0.124 0.124
Strip and store-Cladding ft 0.087 0.087 0.087
Strip, store and refit-Insulation and Cladding ft 0.278 0.278 0.278
Strip, store and refit-Cladding ft 0.195 0.195 0.195
Strip, store and refit Cladding;remove and renew Insulation ft 0.270 0.270 0.270
Extra over Elbow or Bend Nr 0.621 0.621 0.621
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.310 0.310 0.310
Extra over Flange Joint Nr 0.887 0.887 0.887
Extra over Valve or Strainer Nr 1.330 1.330 1.330
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.931 0.931 0.931
Strip, remove and renew Cladding only ft 0.176 0.176 0.176
Strip, remove and renew Complete Specification ft 0.252 0.252 0.252
Extra over Elbow or Bend Nr 0.578 0.578 0.578
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.289 0.289 0.289
Extra over Flange Joint Nr 0.826 0.826 0.826
Extra over Valve or Strainer Nr 1.238 1.238 1.238
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.867 0.867 0.867
Unit12" pipe sizeInsulation Thickness1" 1 1/2" 2"
175
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.204 0.204 0.204
Extra over Elbow or Bend Nr 0.469 0.469 0.469
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.234 0.234 0.234
Extra over Flange Joint Nr 0.670 0.670 0.670
Extra over Valve or Strainer Nr 1.005 1.005 1.005
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.703 0.703 0.703
Strip and remove to skip-Insulation and Cladding ft 0.112 0.112 0.112
Extra over Elbow or Bend Nr 0.258 0.258 0.258
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.129 0.129 0.129
Extra over Flange Joint Nr 0.368 0.368 0.368
Extra over Valve or Strainer Nr 0.553 0.553 0.553
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.387 0.387 0.387
Strip and remove to skip-Cladding only ft 0.079 0.079 0.079
Strip and store-Insulation and Cladding ft 0.156 0.156 0.156
Strip and store-Cladding ft 0.109 0.109 0.109
Strip, store and refit-Insulation and Cladding ft 0.350 0.350 0.350
Strip, store and refit-Cladding ft 0.245 0.245 0.245
Strip, store and refit Cladding;remove and renew Insulation ft 0.340 0.340 0.340
Extra over Elbow or Bend Nr 0.781 0.781 0.781
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.390 0.390 0.390
Extra over Flange Joint Nr 1.115 1.115 1.115
Extra over Valve or Strainer Nr 1.673 1.673 1.673
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.171 1.171 1.171
Strip, remove and renew Cladding only ft 0.222 0.222 0.222
Strip, remove and renew Complete Specification ft 0.317 0.317 0.317
Extra over Elbow or Bend Nr 0.727 0.727 0.727
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.363 0.363 0.363
Extra over Flange Joint Nr 1.038 1.038 1.038
Extra over Valve or Strainer Nr 1.557 1.557 1.557
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.090 1.090 1.090
Unit14" pipe sizeInsulation Thickness1" 1 1/2" 2"
176
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.204 0.204 0.204
Extra over Elbow or Bend Nr 0.469 0.469 0.469
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.234 0.234 0.234
Extra over Flange Joint Nr 0.670 0.670 0.670
Extra over Valve or Strainer Nr 1.005 1.005 1.005
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.703 0.703 0.703
Strip and remove to skip-Insulation and Cladding ft 0.112 0.112 0.112
Extra over Elbow or Bend Nr 0.258 0.258 0.258
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.129 0.129 0.129
Extra over Flange Joint Nr 0.368 0.368 0.368
Extra over Valve or Strainer Nr 0.553 0.553 0.553
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.387 0.387 0.387
Strip and remove to skip-Cladding only ft 0.079 0.079 0.079
Strip and store-Insulation and Cladding ft 0.156 0.156 0.156
Strip and store-Cladding ft 0.109 0.109 0.109
Strip, store and refit-Insulation and Cladding ft 0.350 0.350 0.350
Strip, store and refit-Cladding ft 0.245 0.245 0.245
Strip, store and refit Cladding;remove and renew Insulation ft 0.340 0.340 0.340
Extra over Elbow or Bend Nr 0.781 0.781 0.781
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.390 0.390 0.390
Extra over Flange Joint Nr 1.115 1.115 1.115
Extra over Valve or Strainer Nr 1.673 1.673 1.673
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.171 1.171 1.171
Strip, remove and renew Cladding only ft 0.222 0.222 0.222
Strip, remove and renew Complete Specification ft 0.317 0.317 0.317
Extra over Elbow or Bend Nr 0.727 0.727 0.727
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.363 0.363 0.363
Extra over Flange Joint Nr 1.038 1.038 1.038
Extra over Valve or Strainer Nr 1.557 1.557 1.557
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.090 1.090 1.090
Unit16" pipe sizeInsulation Thickness1" 1 1/2" 2"
177
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.241 0.241 0.241
Extra over Elbow or Bend Nr 0.554 0.554 0.554
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.277 0.277 0.277
Extra over Flange Joint Nr 0.791 0.791 0.791
Extra over Valve or Strainer Nr 1.187 1.187 1.187
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.831 0.831 0.831
Strip and remove to skip-Insulation and Cladding ft 0.133 0.133 0.133
Extra over Elbow or Bend Nr 0.305 0.305 0.305
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.152 0.152 0.152
Extra over Flange Joint Nr 0.435 0.435 0.435
Extra over Valve or Strainer Nr 0.653 0.653 0.653
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.457 0.457 0.457
Strip and remove to skip-Cladding only ft 0.093 0.093 0.093
Strip and store-Insulation and Cladding ft 0.185 0.185 0.185
Strip and store-Cladding ft 0.129 0.129 0.129
Strip, store and refit-Insulation and Cladding ft 0.414 0.414 0.414
Strip, store and refit-Cladding ft 0.290 0.290 0.290
Strip, store and refit Cladding;remove and renew Insulation ft 0.402 0.402 0.402
Extra over Elbow or Bend Nr 0.922 0.922 0.922
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.461 0.461 0.461
Extra over Flange Joint Nr 1.318 1.318 1.318
Extra over Valve or Strainer Nr 1.976 1.976 1.976
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.383 1.383 1.383
Strip, remove and renew Cladding only ft 0.262 0.262 0.262
Strip, remove and renew Complete Specification ft 0.374 0.374 0.374
Extra over Elbow or Bend Nr 0.859 0.859 0.859
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.429 0.429 0.429
Extra over Flange Joint Nr 1.227 1.227 1.227
Extra over Valve or Strainer Nr 1.840 1.840 1.840
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.288 1.288 1.288
18" pipe size UnitInsulation Thickness1" 1 1/2" 2"
178
POLYISOCYANURATE PREFORMED SECTIONS: UP TO 24 MIL A LUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm NormNew Complete Specification ft 0.241 0.241 0.241
Extra over Elbow or Bend Nr 0.554 0.554 0.554
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.277 0.277 0.277
Extra over Flange Joint Nr 0.791 0.791 0.791
Extra over Valve or Strainer Nr 1.187 1.187 1.187
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.831 0.831 0.831
Strip and remove to skip-Insulation and Cladding ft 0.133 0.133 0.133
Extra over Elbow or Bend Nr 0.305 0.305 0.305
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.152 0.152 0.152
Extra over Flange Joint Nr 0.435 0.435 0.435
Extra over Valve or Strainer Nr 0.653 0.653 0.653
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.457 0.457 0.457
Strip and remove to skip-Cladding only ft 0.093 0.093 0.093
Strip and store-Insulation and Cladding ft 0.185 0.185 0.185
Strip and store-Cladding ft 0.129 0.129 0.129
Strip, store and refit-Insulation and Cladding ft 0.414 0.414 0.414
Strip, store and refit-Cladding ft 0.290 0.290 0.290
Strip, store and refit Cladding;remove and renew Insulation ft 0.402 0.402 0.402
Extra over Elbow or Bend Nr 0.922 0.922 0.922
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.461 0.461 0.461
Extra over Flange Joint Nr 1.318 1.318 1.318
Extra over Valve or Strainer Nr 1.976 1.976 1.976
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.383 1.383 1.383
Strip, remove and renew Cladding only ft 0.262 0.262 0.262
Strip, remove and renew Complete Specification ft 0.374 0.374 0.374
Extra over Elbow or Bend Nr 0.859 0.859 0.859
Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.429 0.429 0.429
Extra over Flange Joint Nr 1.227 1.227 1.227
Extra over Valve or Strainer Nr 1.840 1.840 1.840
Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.288 1.288 1.288
Unit20" pipe sizeInsulation Thickness1" 1 1/2" 2"
179
L.2.3 Calcium Silicate Preformed Section: up to 24 mil Aluzinc or Aluminium Flat Rolled Casing to Pipework CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.082 0.082 0.082 0.082 0.113 0.119Extra over Elbow or Bend Nr 0.189 0.189 0.189 0.189 0.260 0.272Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.095 0.095 0.095 0.095 0.130 0.136Extra over Flange Joint-mineral wool Nr 0.270 0.270 0.270 0.270 0.372 0.389Extra over Flange Joint-foamglass Nr 0.324 0.324 0.324 0.324 0.447 0.467Extra over Valve or Strainer-mineral wool Nr 0.406 0.406 0.406 0.406 0.558 0.584Extra over Valve or Strainer-foamglass Nr 0.487 0.487 0.487 0.487 0.670 0.700Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.284 0.284 0.284 0.284 0.391 0.409Strip, remove and renew complete specification ft 0.128 0.128 0.128 0.128 0.176 0.184Extra over Elbow or Bend Nr 0.293 0.293 0.293 0.293 0.404 0.422Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.147 0.147 0.147 0.147 0.202 0.211Extra over Flange Joint-mineral wool Nr 0.419 0.419 0.419 0.419 0.577 0.603Extra over Flange Joint-foamglass Nr 0.503 0.503 0.503 0.503 0.692 0.724Extra over Valve or Strainer-mineral wool Nr 0.629 0.629 0.629 0.629 0.865 0.905Extra over Valve or Strainer-foamglass Nr 0.754 0.754 0.754 0.754 1.038 1.086Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.440 0.440 0.440 0.440 0.606 0.633Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045 0.045 0.062 0.065Extra over Elbow or Bend Nr 0.104 0.104 0.104 0.104 0.143 0.150Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.052 0.052 0.052 0.052 0.072 0.075Extra over Flange Joint-mineral wool or Foamglass Nr 0.149 0.149 0.149 0.149 0.205 0.214Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.223 0.223 0.223 0.223 0.307 0.321Strip and remove to skip-Cladding only ft 0.032 0.032 0.032 0.032 0.044 0.046Strip and store-Insulation and Cladding ft 0.063 0.063 0.063 0.063 0.087 0.091Strip and store-Cladding ft 0.044 0.044 0.044 0.044 0.061 0.063Strip, store and refit-Insulation and Cladding ft 0.141 0.141 0.141 0.141 0.195 0.203Strip, store and refit-Cladding ft 0.099 0.099 0.099 0.099 0.136 0.142Strip, store and refit-Cladding;remove and renew Insulation ft 0.137 0.137 0.137 0.137 0.189 0.198Extra over Elbow or Bend Nr 0.315 0.315 0.315 0.315 0.434 0.453Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.158 0.158 0.158 0.158 0.217 0.227Extra over Flange Joint-mineral wool Nr 0.450 0.450 0.450 0.450 0.620 0.648Extra over Valve or Strainer-mineral wool Nr 0.675 0.675 0.675 0.675 0.929 0.972Strip, remove and renew Cladding only ft 0.089 0.089 0.089 0.089 0.123 0.129
Unit1/2" pipe size 3" 4."Insulation Thickness
1" 1 1/2" 2" 2 1/2"
180
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.082 0.082 0.082 0.082 0.113 0.119Extra over Elbow or Bend Nr 0.189 0.189 0.189 0.189 0.260 0.272Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.095 0.095 0.095 0.095 0.130 0.136Extra over Flange Joint-mineral wool Nr 0.270 0.270 0.270 0.270 0.372 0.389Extra over Flange Joint-foamglass Nr 0.324 0.324 0.324 0.324 0.447 0.467Extra over Valve or Strainer-mineral wool Nr 0.406 0.406 0.406 0.406 0.558 0.584Extra over Valve or Strainer-foamglass Nr 0.487 0.487 0.487 0.487 0.670 0.700Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.284 0.284 0.284 0.284 0.391 0.409Strip, remove and renew complete specification ft 0.128 0.128 0.128 0.128 0.176 0.184Extra over Elbow or Bend Nr 0.293 0.293 0.293 0.293 0.404 0.422Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.147 0.147 0.147 0.147 0.202 0.211Extra over Flange Joint-mineral wool Nr 0.419 0.419 0.419 0.419 0.577 0.603Extra over Flange Joint-foamglass Nr 0.503 0.503 0.503 0.503 0.692 0.724Extra over Valve or Strainer-mineral wool Nr 0.629 0.629 0.629 0.629 0.865 0.905Extra over Valve or Strainer-foamglass Nr 0.754 0.754 0.754 0.754 1.038 1.086Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.440 0.440 0.440 0.440 0.606 0.633Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045 0.045 0.062 0.065Extra over Elbow or Bend Nr 0.104 0.104 0.104 0.104 0.143 0.150Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.052 0.052 0.052 0.052 0.072 0.075Extra over Flange Joint-mineral wool or Foamglass Nr 0.149 0.149 0.149 0.149 0.205 0.214Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.223 0.223 0.223 0.223 0.307 0.321Strip and remove to skip-Cladding only ft 0.032 0.032 0.032 0.032 0.044 0.046Strip and store-Insulation and Cladding ft 0.063 0.063 0.063 0.063 0.087 0.091Strip and store-Cladding ft 0.044 0.044 0.044 0.044 0.061 0.063Strip, store and refit-Insulation and Cladding ft 0.141 0.141 0.141 0.141 0.195 0.203Strip, store and refit-Cladding ft 0.099 0.099 0.099 0.099 0.136 0.142Strip, store and refit-Cladding;remove and renew Insulation ft 0.137 0.137 0.137 0.137 0.189 0.198Extra over Elbow or Bend Nr 0.315 0.315 0.315 0.315 0.434 0.453Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.158 0.158 0.158 0.158 0.217 0.227Extra over Flange Joint-mineral wool Nr 0.450 0.450 0.450 0.450 0.620 0.648Extra over Valve or Strainer-mineral wool Nr 0.675 0.675 0.675 0.675 0.929 0.972Strip, remove and renew Cladding only ft 0.089 0.089 0.089 0.089 0.123 0.129
3/4" pipe size Unit 4."1" 1 1/2" 2" 2 1/2"Insulation Thickness
3"
181
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.082 0.082 0.082 0.082 0.113 0.119Extra over Elbow or Bend Nr 0.189 0.189 0.189 0.189 0.260 0.272Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.095 0.095 0.095 0.095 0.130 0.136Extra over Flange Joint-mineral wool Nr 0.270 0.270 0.270 0.270 0.372 0.389Extra over Flange Joint-foamglass Nr 0.324 0.324 0.324 0.324 0.447 0.467Extra over Valve or Strainer-mineral wool Nr 0.406 0.406 0.406 0.406 0.558 0.584Extra over Valve or Strainer-foamglass Nr 0.487 0.487 0.487 0.487 0.670 0.700Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.284 0.284 0.284 0.284 0.391 0.409Strip, remove and renew complete specification ft 0.128 0.128 0.128 0.128 0.176 0.184Extra over Elbow or Bend Nr 0.293 0.293 0.293 0.293 0.404 0.422Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.147 0.147 0.147 0.147 0.202 0.211Extra over Flange Joint-mineral wool Nr 0.419 0.419 0.419 0.419 0.577 0.603Extra over Flange Joint-foamglass Nr 0.503 0.503 0.503 0.503 0.692 0.724Extra over Valve or Strainer-mineral wool Nr 0.629 0.629 0.629 0.629 0.865 0.905Extra over Valve or Strainer-foamglass Nr 0.754 0.754 0.754 0.754 1.038 1.086Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.440 0.440 0.440 0.440 0.606 0.633Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045 0.045 0.062 0.065Extra over Elbow or Bend Nr 0.104 0.104 0.104 0.104 0.143 0.150Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.052 0.052 0.052 0.052 0.072 0.075Extra over Flange Joint-mineral wool or Foamglass Nr 0.149 0.149 0.149 0.149 0.205 0.214Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.223 0.223 0.223 0.223 0.307 0.321Strip and remove to skip-Cladding only ft 0.032 0.032 0.032 0.032 0.044 0.046Strip and store-Insulation and Cladding ft 0.063 0.063 0.063 0.063 0.087 0.091Strip and store-Cladding ft 0.044 0.044 0.044 0.044 0.061 0.063Strip, store and refit-Insulation and Cladding ft 0.141 0.141 0.141 0.141 0.195 0.203Strip, store and refit-Cladding ft 0.099 0.099 0.099 0.099 0.136 0.142Strip, store and refit-Cladding;remove and renew Insulation ft 0.137 0.137 0.137 0.137 0.189 0.198Extra over Elbow or Bend Nr 0.315 0.315 0.315 0.315 0.434 0.453Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.158 0.158 0.158 0.158 0.217 0.227Extra over Flange Joint-mineral wool Nr 0.450 0.450 0.450 0.450 0.620 0.648Extra over Valve or Strainer-mineral wool Nr 0.675 0.675 0.675 0.675 0.929 0.972Strip, remove and renew Cladding only ft 0.089 0.089 0.089 0.089 0.123 0.129
1" pipe size Unit 4."Insulation Thickness
1" 1 1/2" 2" 2 1/2" 3"
182
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.082 0.082 0.082 0.082 0.113 0.119Extra over Elbow or Bend Nr 0.189 0.189 0.189 0.189 0.260 0.272Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.095 0.095 0.095 0.095 0.130 0.136Extra over Flange Joint-mineral wool Nr 0.270 0.270 0.270 0.270 0.372 0.389Extra over Flange Joint-foamglass Nr 0.324 0.324 0.324 0.324 0.447 0.467Extra over Valve or Strainer-mineral wool Nr 0.406 0.406 0.406 0.406 0.558 0.584Extra over Valve or Strainer-foamglass Nr 0.487 0.487 0.487 0.487 0.670 0.700Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.284 0.284 0.284 0.284 0.391 0.409Strip, remove and renew complete specification ft 0.128 0.128 0.128 0.128 0.176 0.184Extra over Elbow or Bend Nr 0.293 0.293 0.293 0.293 0.404 0.422Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.147 0.147 0.147 0.147 0.202 0.211Extra over Flange Joint-mineral wool Nr 0.419 0.419 0.419 0.419 0.577 0.603Extra over Flange Joint-foamglass Nr 0.503 0.503 0.503 0.503 0.692 0.724Extra over Valve or Strainer-mineral wool Nr 0.629 0.629 0.629 0.629 0.865 0.905Extra over Valve or Strainer-foamglass Nr 0.754 0.754 0.754 0.754 1.038 1.086Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.440 0.440 0.440 0.440 0.606 0.633Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045 0.045 0.062 0.065Extra over Elbow or Bend Nr 0.104 0.104 0.104 0.104 0.143 0.150Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.052 0.052 0.052 0.052 0.072 0.075Extra over Flange Joint-mineral wool or Foamglass Nr 0.149 0.149 0.149 0.149 0.205 0.214Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.223 0.223 0.223 0.223 0.307 0.321Strip and remove to skip-Cladding only ft 0.032 0.032 0.032 0.032 0.044 0.046Strip and store-Insulation and Cladding ft 0.063 0.063 0.063 0.063 0.087 0.091Strip and store-Cladding ft 0.044 0.044 0.044 0.044 0.061 0.063Strip, store and refit-Insulation and Cladding ft 0.141 0.141 0.141 0.141 0.195 0.203Strip, store and refit-Cladding ft 0.099 0.099 0.099 0.099 0.136 0.142Strip, store and refit-Cladding;remove and renew Insulation ft 0.137 0.137 0.137 0.137 0.189 0.198Extra over Elbow or Bend Nr 0.315 0.315 0.315 0.315 0.434 0.453Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.158 0.158 0.158 0.158 0.217 0.227Extra over Flange Joint-mineral wool Nr 0.450 0.450 0.450 0.450 0.620 0.648Extra over Valve or Strainer-mineral wool Nr 0.675 0.675 0.675 0.675 0.929 0.972Strip, remove and renew Cladding only ft 0.089 0.089 0.089 0.089 0.123 0.129
1 1/2" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4."
183
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.082 0.082 0.082 0.082 0.113 0.119Extra over Elbow or Bend Nr 0.189 0.189 0.189 0.189 0.260 0.272Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.095 0.095 0.095 0.095 0.130 0.136Extra over Flange Joint-mineral wool Nr 0.270 0.270 0.270 0.270 0.372 0.389Extra over Flange Joint-foamglass Nr 0.324 0.324 0.324 0.324 0.447 0.467Extra over Valve or Strainer-mineral wool Nr 0.406 0.406 0.406 0.406 0.558 0.584Extra over Valve or Strainer-foamglass Nr 0.487 0.487 0.487 0.487 0.670 0.700Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.284 0.284 0.284 0.284 0.391 0.409Strip, remove and renew complete specification ft 0.128 0.128 0.128 0.128 0.176 0.184Extra over Elbow or Bend Nr 0.293 0.293 0.293 0.293 0.404 0.422Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.147 0.147 0.147 0.147 0.202 0.211Extra over Flange Joint-mineral wool Nr 0.419 0.419 0.419 0.419 0.577 0.603Extra over Flange Joint-foamglass Nr 0.503 0.503 0.503 0.503 0.692 0.724Extra over Valve or Strainer-mineral wool Nr 0.629 0.629 0.629 0.629 0.865 0.905Extra over Valve or Strainer-foamglass Nr 0.754 0.754 0.754 0.754 1.038 1.086Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.440 0.440 0.440 0.440 0.606 0.633Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045 0.045 0.062 0.065Extra over Elbow or Bend Nr 0.104 0.104 0.104 0.104 0.143 0.150Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.052 0.052 0.052 0.052 0.072 0.075Extra over Flange Joint-mineral wool or Foamglass Nr 0.149 0.149 0.149 0.149 0.205 0.214Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.223 0.223 0.223 0.223 0.307 0.321Strip and remove to skip-Cladding only ft 0.032 0.032 0.032 0.032 0.044 0.046Strip and store-Insulation and Cladding ft 0.063 0.063 0.063 0.063 0.087 0.091Strip and store-Cladding ft 0.044 0.044 0.044 0.044 0.061 0.063Strip, store and refit-Insulation and Cladding ft 0.141 0.141 0.141 0.141 0.195 0.203Strip, store and refit-Cladding ft 0.099 0.099 0.099 0.099 0.136 0.142Strip, store and refit-Cladding;remove and renew Insulation ft 0.137 0.137 0.137 0.137 0.189 0.198Extra over Elbow or Bend Nr 0.315 0.315 0.315 0.315 0.434 0.453Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.158 0.158 0.158 0.158 0.217 0.227Extra over Flange Joint-mineral wool Nr 0.450 0.450 0.450 0.450 0.620 0.648Extra over Valve or Strainer-mineral wool Nr 0.675 0.675 0.675 0.675 0.929 0.972Strip, remove and renew Cladding only ft 0.089 0.089 0.089 0.089 0.123 0.129
2" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4."
184
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.101 0.101 0.101 0.101 0.126 0.134Extra over Elbow or Bend Nr 0.231 0.231 0.231 0.231 0.290 0.307Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.115 0.115 0.115 0.115 0.145 0.154Extra over Flange Joint-mineral wool Nr 0.330 0.330 0.330 0.330 0.414 0.439Extra over Flange Joint-foamglass Nr 0.396 0.396 0.396 0.396 0.497 0.527Extra over Valve or Strainer-mineral wool Nr 0.495 0.495 0.495 0.495 0.621 0.658Extra over Valve or Strainer-foamglass Nr 0.593 0.593 0.593 0.593 0.745 0.790Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.346 0.346 0.346 0.346 0.435 0.461Strip, remove and renew complete specification ft 0.156 0.156 0.156 0.156 0.196 0.207Extra over Elbow or Bend Nr 0.358 0.358 0.358 0.358 0.449 0.476Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.179 0.179 0.179 0.179 0.225 0.238Extra over Flange Joint-mineral wool Nr 0.511 0.511 0.511 0.511 0.642 0.680Extra over Flange Joint-foamglass Nr 0.613 0.613 0.613 0.613 0.770 0.816Extra over Valve or Strainer-mineral wool Nr 0.767 0.767 0.767 0.767 0.963 1.020Extra over Valve or Strainer-foamglass Nr 0.920 0.920 0.920 0.920 1.155 1.225Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.537 0.537 0.537 0.537 0.674 0.714Strip and remove to skip-Insulation and Cladding ft 0.055 0.055 0.055 0.055 0.069 0.074Extra over Elbow or Bend Nr 0.127 0.127 0.127 0.127 0.159 0.169Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.063 0.063 0.063 0.063 0.080 0.084Extra over Flange Joint-mineral wool or Foamglass Nr 0.181 0.181 0.181 0.181 0.228 0.241Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.272 0.272 0.272 0.272 0.342 0.362Strip and remove to skip-Cladding only ft 0.039 0.039 0.039 0.039 0.049 0.052Strip and store-Insulation and Cladding ft 0.077 0.077 0.077 0.077 0.097 0.102Strip and store-Cladding ft 0.054 0.054 0.054 0.054 0.068 0.072Strip, store and refit-Insulation and Cladding ft 0.172 0.172 0.172 0.172 0.216 0.229Extra over Elbow or Bend Nr 0.396 0.497Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.198 0.249Strip, store and refit-Cladding ft 0.121 0.121 0.121 0.121 0.151 0.161Strip, store and refit-Cladding;remove and renew Insulation ft 0.167 0.167 0.167 0.167 0.210 0.223Extra over Elbow or Bend Nr 0.384 0.384 0.384 0.384 0.483 0.512Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.192 0.192 0.192 0.192 0.241 0.256Extra over Flange Joint-mineral wool Nr 0.549 0.549 0.549 0.549 0.689 0.731Extra over Valve or Strainer-mineral wool Nr 0.823 0.823 0.823 0.823 1.034 1.096Strip, remove and renew Cladding only ft 0.109 0.109 0.109 0.109 0.137 0.145
Unit3" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4."
185
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.101 0.101 0.101 0.101 0.126 0.134Extra over Elbow or Bend Nr 0.231 0.231 0.231 0.231 0.290 0.307Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.115 0.115 0.115 0.115 0.145 0.154Extra over Flange Joint-mineral wool Nr 0.330 0.330 0.330 0.330 0.414 0.439Extra over Flange Joint-foamglass Nr 0.396 0.396 0.396 0.396 0.497 0.527Extra over Valve or Strainer-mineral wool Nr 0.495 0.495 0.495 0.495 0.621 0.658Extra over Valve or Strainer-foamglass Nr 0.593 0.593 0.593 0.593 0.745 0.790Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.346 0.346 0.346 0.346 0.435 0.461Strip, remove and renew complete specification ft 0.156 0.156 0.156 0.156 0.196 0.207Extra over Elbow or Bend Nr 0.358 0.358 0.358 0.358 0.449 0.476Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.179 0.179 0.179 0.179 0.225 0.238Extra over Flange Joint-mineral wool Nr 0.511 0.511 0.511 0.511 0.642 0.680Extra over Flange Joint-foamglass Nr 0.613 0.613 0.613 0.613 0.770 0.816Extra over Valve or Strainer-mineral wool Nr 0.767 0.767 0.767 0.767 0.963 1.020Extra over Valve or Strainer-foamglass Nr 0.920 0.920 0.920 0.920 1.155 1.225Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.537 0.537 0.537 0.537 0.674 0.714Strip and remove to skip-Insulation and Cladding ft 0.055 0.055 0.055 0.055 0.069 0.074Extra over Elbow or Bend Nr 0.127 0.127 0.127 0.127 0.159 0.169Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.063 0.063 0.063 0.063 0.080 0.084Extra over Flange Joint-mineral wool or Foamglass Nr 0.181 0.181 0.181 0.181 0.228 0.241Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.272 0.272 0.272 0.272 0.342 0.362Strip and remove to skip-Cladding only ft 0.039 0.039 0.039 0.039 0.049 0.052Strip and store-Insulation and Cladding ft 0.077 0.077 0.077 0.077 0.097 0.102Strip and store-Cladding ft 0.054 0.054 0.054 0.054 0.068 0.072Strip, store and refit-Insulation and Cladding ft 0.172 0.172 0.172 0.172 0.216 0.229Strip, store and refit-Cladding ft 0.121 0.121 0.121 0.121 0.151 0.161Strip, store and refit-Cladding;remove and renew Insulation ft 0.167 0.167 0.167 0.167 0.210 0.223Extra over Elbow or Bend Nr 0.384 0.384 0.384 0.384 0.483 0.512Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.192 0.192 0.192 0.192 0.241 0.256Extra over Flange Joint-mineral wool Nr 0.549 0.549 0.549 0.549 0.689 0.731Extra over Valve or Strainer-mineral wool Nr 0.823 0.823 0.823 0.823 1.034 1.096Strip, remove and renew Cladding only ft 0.109 0.109 0.109 0.109 0.137 0.145
4" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4."
186
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.101 0.101 0.101 0.101 0.126 0.134 0.134 0.165 0.165 0.165Extra over Elbow or Bend Nr 0.231 0.231 0.231 0.231 0.290 0.307 0.307 0.378 0.378 0.378Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.115 0.115 0.115 0.115 0.145 0.154 0.154 0.189 0.189 0.189Extra over Flange Joint-mineral wool Nr 0.330 0.330 0.330 0.330 0.414 0.439 0.439 0.541 0.541 0.541Extra over Flange Joint-foamglass Nr 0.396 0.396 0.396 0.396 0.497 0.527 0.527 0.649 0.649 0.649Extra over Valve or Strainer-mineral wool Nr 0.495 0.495 0.495 0.495 0.621 0.658 0.658 0.811 0.811 0.811Extra over Valve or Strainer-foamglass Nr 0.593 0.593 0.593 0.593 0.745 0.790 0.790 0.973 0.973 0.973Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.346 0.346 0.346 0.346 0.435 0.461 0.461 0.568 0.568 0.568Strip, remove and renew complete specification ft 0.156 0.156 0.156 0.156 0.196 0.207 0.207 0.256 0.256 0.256Extra over Elbow or Bend Nr 0.358 0.358 0.358 0.358 0.449 0.476 0.476 0.587 0.587 0.587Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.179 0.179 0.179 0.179 0.225 0.238 0.238 0.293 0.293 0.293Extra over Flange Joint-mineral wool Nr 0.511 0.511 0.511 0.511 0.642 0.680 0.680 0.838 0.838 0.838Extra over Flange Joint-foamglass Nr 0.613 0.613 0.613 0.613 0.770 0.816 0.816 1.006 1.006 1.006Extra over Valve or Strainer-mineral wool Nr 0.767 0.767 0.767 0.767 0.963 1.020 1.020 1.257 1.257 1.257Extra over Valve or Strainer-foamglass Nr 0.920 0.920 0.920 0.920 1.155 1.225 1.225 1.509 1.509 1.509Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.537 0.537 0.537 0.537 0.674 0.714 0.714 0.880 0.880 0.880Strip and remove to skip-Insulation and Cladding ft 0.055 0.055 0.055 0.055 0.069 0.074 0.074 0.091 0.091 0.091Extra over Elbow or Bend Nr 0.127 0.127 0.127 0.127 0.159 0.169 0.169 0.208 0.208 0.208Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.063 0.063 0.063 0.063 0.080 0.084 0.084 0.104 0.104 0.104Extra over Flange Joint-mineral wool Nr 0.181 0.181 0.181 0.181 0.228 0.241 0.241 0.297 0.297 0.297Extra over Valve or Strainer-mineral wool Nr 0.272 0.272 0.272 0.272 0.342 0.362 0.362 0.446 0.446 0.446Strip and remove to skip-Cladding only ft 0.039 0.039 0.039 0.039 0.049 0.052 0.052 0.063 0.063 0.063Strip and store-Insulation and Cladding ft 0.077 0.077 0.077 0.077 0.097 0.102 0.102 0.126 0.126 0.126Strip and store-Cladding ft 0.054 0.054 0.054 0.054 0.068 0.072 0.072 0.088 0.088 0.088Strip, store and refit-Insulation and Cladding ft 0.172 0.172 0.172 0.172 0.216 0.229 0.229 0.283 0.283 0.283Strip, store and refit-Cladding ft 0.121 0.121 0.121 0.121 0.151 0.161 0.161 0.198 0.198 0.198Strip, store and refit-Cladding;remove and renew Insulation ft 0.167 0.167 0.167 0.167 0.210 0.223 0.223 0.274 0.274 0.274Extra over Elbow or Bend Nr 0.384 0.384 0.384 0.384 0.483 0.512 0.512 0.630 0.630 0.630Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.192 0.192 0.192 0.192 0.241 0.256 0.256 0.315 0.315 0.315Extra over Flange Joint-mineral wool Nr 0.549 0.549 0.549 0.549 0.689 0.731 0.731 0.900 0.900 0.900Extra over Valve or Strainer-mineral wool Nr 0.823 0.823 0.823 0.823 1.034 1.096 1.096 1.350 1.350 1.350Strip, remove and renew Cladding only ft 0.109 0.109 0.109 0.109 0.137 0.145 0.145 0.179 0.179 0.179Extra over Elbow or Bend Nr 0.250
6" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 5"4 1/2"4" 5 1/2" 6"
187
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
New Complete Specification ft 0.126 0.126 0.126 0.126 0.160 0.165 0.165 0.209 0.209 0.209Extra over Elbow or Bend Nr 0.290 0.290 0.290 0.290 0.367 0.378 0.378 0.479 0.479 0.479Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.145 0.145 0.145 0.145 0.183 0.189 0.189 0.240 0.240 0.240Extra over Flange Joint-mineral wool Nr 0.414 0.414 0.414 0.414 0.524 0.541 0.541 0.684 0.684 0.684Extra over Flange Joint-foamglass Nr 0.497 0.497 0.497 0.497 0.628 0.649 0.649 0.821 0.821 0.821Extra over Valve or Strainer-mineral wool Nr 0.621 0.621 0.621 0.621 0.786 0.811 0.811 1.027 1.027 1.027Extra over Valve or Strainer-foamglass Nr 0.745 0.745 0.745 0.745 0.943 0.973 0.973 1.232 1.232 1.232Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.435 0.435 0.435 0.435 0.550 0.568 0.568 0.719 0.719 0.719Strip, remove and renew complete specification ft 0.196 0.196 0.196 0.196 0.247 0.256 0.256 0.323 0.323 0.323Extra over Elbow or Bend Nr 0.449 0.449 0.449 0.449 0.568 0.587 0.587 0.743 0.743 0.743Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.225 0.225 0.225 0.225 0.284 0.293 0.293 0.371 0.371 0.371Extra over Flange Joint-mineral wool Nr 0.642 0.642 0.642 0.642 0.812 0.838 0.838 1.061 1.061 1.061Extra over Flange Joint-foamglass Nr 0.770 0.770 0.770 0.770 0.974 1.006 1.006 1.273 1.273 1.273Extra over Valve or Strainer-mineral wool Nr 0.963 0.963 0.963 0.963 1.218 1.257 1.257 1.591 1.591 1.591Extra over Valve or Strainer-foamglass Nr 1.155 1.155 1.155 1.155 1.461 1.509 1.509 1.909 1.909 1.909Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.674 0.674 0.674 0.674 0.852 0.880 0.880 1.114 1.114 1.114Strip and remove to skip-Insulation and Cladding ft 0.069 0.069 0.069 0.069 0.088 0.091 0.091 0.115 0.115 0.115Extra over Elbow or Bend Nr 0.159 0.159 0.159 0.159 0.202 0.208 0.208 0.263 0.263 0.263Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.080 0.080 0.080 0.080 0.101 0.104 0.104 0.132 0.132 0.132Extra over Flange Joint-mineral wool Nr 0.228 0.228 0.228 0.228 0.288 0.297 0.297 0.376 0.376 0.376Extra over Valve or Strainer-mineral wool Nr 0.342 0.342 0.342 0.342 0.432 0.446 0.446 0.565 0.565 0.565Strip and remove to skip-Cladding only ft 0.049 0.049 0.049 0.049 0.061 0.063 0.063 0.080 0.080 0.080Strip and store-Insulation and Cladding ft 0.097 0.097 0.097 0.097 0.122 0.126 0.126 0.160 0.160 0.160Strip and store-Cladding ft 0.068 0.068 0.068 0.068 0.085 0.088 0.088 0.112 0.112 0.112Strip, store and refit-Insulation and Cladding ft 0.216 0.216 0.216 0.216 0.274 0.283 0.283 0.358 0.358 0.358Strip, store and refit-Cladding ft 0.151 0.151 0.151 0.151 0.192 0.198 0.198 0.250 0.250 0.250Strip, store and refit-Cladding;remove and renew Insulation ft 0.210 0.210 0.210 0.210 0.266 0.274 0.274 0.347 0.347 0.347Extra over Elbow or Bend Nr 0.483 0.483 0.483 0.483 0.610 0.630 0.630 0.798 0.798 0.798Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.241 0.241 0.241 0.241 0.305 0.315 0.315 0.399 0.399 0.399Extra over Flange Joint-mineral wool Nr 0.689 0.689 0.689 0.689 0.872 0.900 0.900 1.139 1.139 1.139Extra over Valve or Strainer-mineral wool Nr 1.034 1.034 1.034 1.034 1.308 1.350 1.350 1.709 1.709 1.709Strip, remove and renew Cladding only ft 0.137 0.137 0.137 0.137 0.173 0.179 0.179 0.226 0.226 0.226Extra over Elbow or Bend Nr 0.314
8" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4" 4 1/2" 6"5" 5 1/2"
188
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
New Complete Specification ft 0.126 0.126 0.126 0.126 0.162 0.168 0.168 0.211 0.211 0.211Extra over Elbow or Bend Nr 0.290 0.290 0.290 0.290 0.373 0.385 0.385 0.485 0.485 0.485Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.145 0.145 0.145 0.145 0.186 0.192 0.192 0.242 0.242 0.242Extra over Flange Joint-mineral wool Nr 0.414 0.414 0.414 0.414 0.533 0.550 0.550 0.693 0.693 0.693Extra over Flange Joint-foamglass Nr 0.497 0.497 0.497 0.497 0.639 0.660 0.660 0.831 0.831 0.831Extra over Valve or Strainer-mineral wool Nr 0.621 0.621 0.621 0.621 0.799 0.825 0.825 1.039 1.039 1.039Extra over Valve or Strainer-foamglass Nr 0.745 0.745 0.745 0.745 0.959 0.989 0.989 1.247 1.247 1.247Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.435 0.435 0.435 0.435 0.559 0.577 0.577 0.727 0.727 0.727Strip, remove and renew complete specification ft 0.196 0.196 0.196 0.196 0.252 0.260 0.260 0.327 0.327 0.327Extra over Elbow or Bend Nr 0.449 0.449 0.449 0.449 0.578 0.596 0.596 0.752 0.752 0.752Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.225 0.225 0.225 0.225 0.289 0.298 0.298 0.376 0.376 0.376Extra over Flange Joint-mineral wool Nr 0.642 0.642 0.642 0.642 0.826 0.852 0.852 1.074 1.074 1.074Extra over Flange Joint-foamglass Nr 0.770 0.770 0.770 0.770 0.991 1.022 1.022 1.289 1.289 1.289Extra over Valve or Strainer-mineral wool Nr 0.963 0.963 0.963 0.963 1.239 1.278 1.278 1.611 1.611 1.611Extra over Valve or Strainer-foamglass Nr 1.155 1.155 1.155 1.155 1.486 1.534 1.534 1.933 1.933 1.933Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.674 0.674 0.674 0.674 0.867 0.895 0.895 1.128 1.128 1.128Strip and remove to skip-Insulation and Cladding ft 0.069 0.069 0.069 0.069 0.089 0.092 0.092 0.116 0.116 0.116Extra over Elbow or Bend Nr 0.159 0.159 0.159 0.159 0.205 0.212 0.212 0.267 0.267 0.267Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.080 0.080 0.080 0.080 0.103 0.106 0.106 0.133 0.133 0.133Extra over Flange Joint-mineral wool Nr 0.228 0.228 0.228 0.228 0.293 0.302 0.302 0.381 0.381 0.381Extra over Valve or Strainer-mineral wool Nr 0.342 0.342 0.342 0.342 0.440 0.454 0.454 0.572 0.572 0.572Strip and remove to skip-Cladding only ft 0.049 0.049 0.049 0.049 0.063 0.065 0.065 0.081 0.081 0.081Strip and store-Insulation and Cladding ft 0.097 0.097 0.097 0.097 0.124 0.128 0.128 0.162 0.162 0.162Strip and store-Cladding ft 0.068 0.068 0.068 0.068 0.087 0.090 0.090 0.113 0.113 0.113Strip, store and refit-Insulation and Cladding ft 0.216 0.216 0.216 0.216 0.279 0.287 0.287 0.362 0.362 0.362Strip, store and refit-Cladding ft 0.151 0.151 0.151 0.151 0.195 0.201 0.201 0.253 0.253 0.253Strip, store and refit-Cladding;remove and renew Insulation ft 0.210 0.210 0.210 0.210 0.270 0.279 0.279 0.352 0.352 0.352Extra over Elbow or Bend Nr 0.483 0.483 0.483 0.483 0.621 0.641 0.641 0.807 0.807 0.807Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.241 0.241 0.241 0.241 0.310 0.320 0.320 0.404 0.404 0.404Extra over Flange Joint-mineral wool Nr 0.689 0.689 0.689 0.689 0.887 0.915 0.915 1.154 1.154 1.154Extra over Valve or Strainer-mineral wool Nr 1.034 1.034 1.034 1.034 1.331 1.373 1.373 1.730 1.730 1.730Strip, remove and renew Cladding only ft 0.137 0.137 0.137 0.137 0.176 0.182 0.182 0.229 0.229 0.229EO Tee, Reducer, Full Cap End or End Closure Plate Nr 0.157
10" pipe size Unit 6"1 1/2" 2" 2 1/2" 3" 4" 4 1/2" 5" 5 1/2"Insulation Thickness
1"
189
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
New Complete Specification ft 0.162 0.162 0.162 0.162 0.204 0.211 0.211 0.263 0.263 0.263Extra over Elbow or Bend Nr 0.373 0.373 0.373 0.373 0.468 0.485 0.485 0.603 0.603 0.603Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.186 0.186 0.186 0.186 0.234 0.242 0.242 0.302 0.302 0.302Extra over Flange Joint-mineral wool Nr 0.533 0.533 0.533 0.533 0.668 0.693 0.693 0.862 0.862 0.862Extra over Flange Joint-foamglass Nr 0.639 0.639 0.639 0.639 0.802 0.831 0.831 1.034 1.034 1.034Extra over Valve or Strainer-mineral wool Nr 0.799 0.799 0.799 0.799 1.002 1.039 1.039 1.293 1.293 1.293Extra over Valve or Strainer-foamglass Nr 0.959 0.959 0.959 0.959 1.202 1.247 1.247 1.551 1.551 1.551Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.559 0.559 0.559 0.559 0.701 0.727 0.727 0.905 0.905 0.905Strip, remove and renew complete specification ft 0.252 0.252 0.252 0.252 0.316 0.327 0.327 0.407 0.407 0.407Extra over Elbow or Bend Nr 0.578 0.578 0.578 0.578 0.725 0.752 0.752 0.935 0.935 0.935Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.289 0.289 0.289 0.289 0.362 0.376 0.376 0.468 0.468 0.468Extra over Flange Joint-mineral wool Nr 0.826 0.826 0.826 0.826 1.035 1.074 1.074 1.336 1.336 1.336Extra over Flange Joint-foamglass Nr 0.991 0.991 0.991 0.991 1.242 1.289 1.289 1.603 1.603 1.603Extra over Valve or Strainer-mineral wool Nr 1.239 1.239 1.239 1.239 1.553 1.611 1.611 2.004 2.004 2.004Extra over Valve or Strainer-foamglass Nr 1.486 1.486 1.486 1.486 1.863 1.933 1.933 2.405 2.405 2.405Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.867 0.867 0.867 0.867 1.087 1.128 1.128 1.403 1.403 1.403Strip and remove to skip-Insulation and Cladding ft 0.089 0.089 0.089 0.089 0.112 0.116 0.116 0.145 0.145 0.145Extra over Elbow or Bend Nr 0.205 0.205 0.205 0.205 0.257 0.267 0.267 0.332 0.332 0.332Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.103 0.103 0.103 0.103 0.129 0.133 0.133 0.166 0.166 0.166Extra over Flange Joint-mineral wool Nr 0.293 0.293 0.293 0.293 0.367 0.381 0.381 0.474 0.474 0.474Extra over Valve or Strainer-mineral wool Nr 0.440 0.440 0.440 0.440 0.551 0.572 0.572 0.711 0.711 0.711Strip and remove to skip-Cladding only ft 0.063 0.063 0.063 0.063 0.078 0.081 0.081 0.101 0.101 0.101Extra over Elbow or Bend Nr 0.187Extra over Flange Joint-mineral wool Nr 0.267Strip and store-Insulation and Cladding ft 0.124 0.124 0.124 0.124 0.156 0.162 0.162 0.201 0.201 0.201Strip and store-Cladding ft 0.087 0.087 0.087 0.087 0.109 0.113 0.113 0.141 0.141 0.141Strip, store and refit-Insulation and Cladding ft 0.279 0.279 0.279 0.279 0.349 0.362 0.362 0.451 0.451 0.451Strip, store and refit-Cladding ft 0.195 0.195 0.195 0.195 0.244 0.253 0.253 0.315 0.315 0.315Strip, store and refit-Cladding;remove and renew Insulation ft 0.270 0.270 0.270 0.270 0.339 0.352 0.352 0.438 0.438 0.438Extra over Elbow or Bend Nr 0.621 0.621 0.621 0.621 0.778 0.807 0.807 1.005 1.005 1.005Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.310 0.310 0.310 0.310 0.389 0.404 0.404 0.502 0.502 0.502Extra over Flange Joint-mineral wool Nr 0.887 0.887 0.887 0.887 1.112 1.154 1.154 1.435 1.435 1.435Extra over Valve or Strainer-mineral wool Nr 1.331 1.331 1.331 1.331 1.668 1.730 1.730 2.153 2.153 2.153Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.931Strip, remove and renew Cladding only ft 0.176 0.176 0.176 0.176 0.221 0.229 0.229 0.285 0.285 0.285Extra over Elbow or Bend Nr 0.405 0.507 0.526Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.263Extra over Flange Joint-mineral wool Nr 0.752Extra over Valve or Strainer-mineral wool Nr 1.128
12" pipe size Unit 6"Insulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4" 4 1/2" 5" 5 1/2"
190
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
New Complete Specification ft 0.162 0.162 0.162 0.204 0.211 0.211 0.263 0.263 0.263Extra over Elbow or Bend Nr 0.373 0.373 0.373 0.468 0.485 0.485 0.603 0.603 0.603Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.186 0.186 0.186 0.234 0.242 0.242 0.302 0.302 0.302Extra over Flange Joint-mineral wool Nr 0.533 0.533 0.533 0.668 0.693 0.693 0.862 0.862 0.862Extra over Flange Joint-foamglass Nr 0.639 0.639 0.639 0.802 0.831 0.831 1.034 1.034 1.034Extra over Valve or Strainer-mineral wool Nr 0.799 0.799 0.799 1.002 1.039 1.039 1.293 1.293 1.293Extra over Valve or Strainer-foamglass Nr 0.959 0.959 0.959 1.202 1.247 1.247 1.551 1.551 1.551Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.559 0.559 0.559 0.701 0.727 0.727 0.905 0.905 0.905Strip, remove and renew complete specification ft 0.252 0.252 0.252 0.316 0.327 0.327 0.407 0.407 0.407Extra over Elbow or Bend Nr 0.578 0.578 0.578 0.725 0.752 0.752 0.935 0.935 0.935Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.289 0.289 0.289 0.362 0.376 0.376 0.468 0.468 0.468Extra over Flange Joint-mineral wool Nr 0.826 0.826 0.826 1.035 1.074 1.074 1.336 1.336 1.336Extra over Flange Joint-foamglass Nr 0.991 0.991 0.991 1.242 1.289 1.289 1.603 1.603 1.603Extra over Valve or Strainer-mineral wool Nr 1.239 1.239 1.239 1.553 1.611 1.611 2.004 2.004 2.004Extra over Valve or Strainer-foamglass Nr 1.486 1.486 1.486 1.863 1.933 1.933 2.405 2.405 2.405Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.867 0.867 0.867 1.087 1.128 1.128 1.403 1.403 1.403Strip and remove to skip-Insulation and Cladding ft 0.089 0.089 0.089 0.112 0.116 0.116 0.145 0.145 0.145Extra over Elbow or Bend Nr 0.205 0.205 0.205 0.257 0.267 0.267 0.332 0.332 0.332Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.103 0.103 0.103 0.129 0.133 0.133 0.166 0.166 0.166Extra over Flange Joint-mineral wool Nr 0.293 0.293 0.293 0.367 0.381 0.381 0.474 0.474 0.474Extra over Valve or Strainer-mineral wool Nr 0.440 0.440 0.440 0.551 0.572 0.572 0.711 0.711 0.711Strip and remove to skip-Cladding only ft 0.063 0.063 0.063 0.078 0.081 0.081 0.101 0.101 0.101Strip and store-Insulation and Cladding ft 0.124 0.124 0.124 0.156 0.162 0.162 0.201 0.201 0.201Strip and store-Cladding ft 0.087 0.087 0.087 0.109 0.113 0.113 0.141 0.141 0.141Strip, store and refit-Insulation and Cladding ft 0.279 0.279 0.279 0.349 0.362 0.362 0.451 0.451 0.451Strip, store and refit-Cladding ft 0.195 0.195 0.195 0.244 0.253 0.253 0.315 0.315 0.315Strip, store and refit-Cladding;remove and renew Insulation ft 0.270 0.270 0.270 0.339 0.352 0.352 0.438 0.438 0.438Extra over Elbow or Bend Nr 0.621 0.621 0.621 0.778 0.807 0.807 1.005 1.005 1.005Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.310 0.310 0.310 0.389 0.404 0.404 0.502 0.502 0.502Extra over Flange Joint-mineral wool Nr 0.887 0.887 0.887 1.112 1.154 1.154 1.435 1.435 1.435Extra over Valve or Strainer-mineral wool Nr 1.331 1.331 1.331 1.668 1.730 1.730 2.153 2.153 2.153Strip, remove and renew Cladding only ft 0.176 0.176 0.176 0.221 0.229 0.229 0.285 0.285 0.285
14" pipe size Unit 5 1/2" 6"Insulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4" 4 1/2" 5"
191
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
New Complete Specification ft 0.193 0.193 0.193 0.235 0.245 0.245 0.304 0.304 0.304Extra over Elbow or Bend Nr 0.444 0.444 0.444 0.538 0.562 0.562 0.698 0.698 0.698Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.222 0.222 0.222 0.269 0.281 0.281 0.349 0.349 0.349Extra over Flange Joint-mineral wool Nr 0.635 0.635 0.635 0.769 0.803 0.803 0.997 0.997 0.997Extra over Flange Joint-foamglass Nr 0.761 0.761 0.761 0.923 0.964 0.964 1.197 1.197 1.197Extra over Valve or Strainer-mineral wool Nr 0.952 0.952 0.952 1.154 1.205 1.205 1.496 1.496 1.496Extra over Valve or Strainer-foamglass Nr 1.142 1.142 1.142 1.384 1.446 1.446 1.795 1.795 1.795Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.666 0.666 0.666 0.808 0.843 0.843 1.047 1.047 1.047Strip, remove and renew complete specification ft 0.300 0.300 0.300 0.363 0.380 0.380 0.471 0.471 0.471Extra over Elbow or Bend Nr 0.688 0.688 0.688 0.835 0.871 0.871 1.082 1.082 1.082Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.344 0.344 0.344 0.417 0.436 0.436 0.541 0.541 0.541Extra over Flange Joint-mineral wool Nr 0.984 0.984 0.984 1.192 1.245 1.245 1.546 1.546 1.546Extra over Flange Joint-foamglass Nr 1.180 1.180 1.180 1.431 1.494 1.494 1.855 1.855 1.855Extra over Valve or Strainer-mineral wool Nr 1.475 1.475 1.475 1.788 1.867 1.867 2.318 2.318 2.318Extra over Valve or Strainer-foamglass Nr 1.770 1.770 1.770 2.146 2.241 2.241 2.782 2.782 2.782Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.033 1.033 1.033 1.252 1.307 1.307 1.623 1.623 1.623Strip and remove to skip-Insulation and Cladding ft 0.106 0.106 0.106 0.129 0.135 0.135 0.167 0.167 0.167Extra over Elbow or Bend Nr 0.244 0.244 0.244 0.296 0.309 0.309 0.384 0.384 0.384Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.122 0.122 0.122 0.148 0.155 0.155 0.192 0.192 0.192Extra over Flange Joint-mineral wool Nr 0.349 0.349 0.349 0.423 0.442 0.442 0.548 0.548 0.548Extra over Valve or Strainer-mineral wool Nr 0.523 0.523 0.523 0.635 0.663 0.663 0.823 0.823 0.823Strip and remove to skip-Cladding only ft 0.074 0.074 0.074 0.090 0.094 0.094 0.117 0.117 0.117Strip and store-Insulation and Cladding ft 0.148 0.148 0.148 0.179 0.187 0.187 0.233 0.233 0.233Strip and store-Cladding ft 0.103 0.103 0.103 0.125 0.131 0.131 0.163 0.163 0.163Strip, store and refit-Insulation and Cladding ft 0.332 0.332 0.332 0.402 0.420 0.420 0.521 0.521 0.521Strip, store and refit-Cladding ft 0.232 0.232 0.232 0.281 0.294 0.294 0.365 0.365 0.365Strip, store and refit-Cladding;remove and renew Insulation ft 0.322 0.322 0.322 0.390 0.408 0.408 0.506 0.506 0.506Extra over Elbow or Bend Nr 0.740 0.740 0.740 0.896 0.936 0.936 1.162 1.162 1.162Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.370 0.370 0.370 0.448 0.468 0.468 0.581 0.581 0.581Extra over Flange Joint-mineral wool Nr 1.056 1.056 1.056 1.281 1.337 1.337 1.660 1.660 1.660Extra over Valve or Strainer-mineral wool Nr 1.585 1.585 1.585 1.921 2.006 2.006 2.490 2.490 2.490Strip, remove and renew Cladding only ft 0.210 0.210 0.210 0.254 0.266 0.266 0.330 0.330 0.330
Unit16" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 6"3" 4" 4 1/2" 5" 5 1/2"
192
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
New Complete Specification ft 0.193 0.193 0.193 0.235 0.245 0.245 0.319 0.319 0.319Extra over Elbow or Bend Nr 0.444 0.444 0.444 0.538 0.562 0.562 0.733 0.733 0.733Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.222 0.222 0.222 0.269 0.281 0.281 0.366 0.366 0.366Extra over Flange Joint-mineral wool Nr 0.635 0.635 0.635 0.769 0.803 0.803 1.047 1.047 1.047Extra over Flange Joint-foamglass Nr 0.761 0.761 0.761 0.923 0.964 0.964 1.256 1.256 1.256Extra over Valve or Strainer-mineral wool Nr 0.952 0.952 0.952 1.154 1.205 1.205 1.570 1.570 1.570Extra over Valve or Strainer-foamglass Nr 1.142 1.142 1.142 1.384 1.446 1.446 1.884 1.884 1.884Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.666 0.666 0.666 0.808 0.843 0.843 1.099 1.099 1.099Strip, remove and renew complete specification ft 0.300 0.300 0.300 0.363 0.380 0.380 0.495 0.495 0.495Extra over Elbow or Bend Nr 0.688 0.688 0.688 0.835 0.871 0.871 1.136 1.136 1.136Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.344 0.344 0.344 0.417 0.436 0.436 0.568 0.568 0.568Extra over Flange Joint-mineral wool Nr 0.984 0.984 0.984 1.192 1.245 1.245 1.623 1.623 1.623Extra over Flange Joint-foamglass Nr 1.180 1.180 1.180 1.431 1.494 1.494 1.947 1.947 1.947Extra over Valve or Strainer-mineral wool Nr 1.475 1.475 1.475 1.788 1.867 1.867 2.434 2.434 2.434Extra over Valve or Strainer-foamglass Nr 1.770 1.770 1.770 2.146 2.241 2.241 2.921 2.921 2.921Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.033 1.033 1.033 1.252 1.307 1.307 1.704 1.704 1.704Strip and remove to skip-Insulation and Cladding ft 0.106 0.106 0.106 0.129 0.135 0.135 0.176 0.176 0.176Extra over Elbow or Bend Nr 0.244 0.244 0.244 0.296 0.309 0.309 0.403 0.403 0.403Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.122 0.122 0.122 0.148 0.155 0.155 0.202 0.202 0.202Extra over Flange Joint-mineral wool Nr 0.349 0.349 0.349 0.423 0.442 0.442 0.576 0.576 0.576Extra over Valve or Strainer-mineral wool Nr 0.523 0.523 0.523 0.635 0.663 0.663 0.864 0.864 0.864Strip and remove to skip-Cladding only ft 0.074 0.074 0.074 0.090 0.094 0.094 0.123 0.123 0.123Strip and store-Insulation and Cladding ft 0.148 0.148 0.148 0.179 0.187 0.187 0.244 0.244 0.244Strip and store-Cladding ft 0.103 0.103 0.103 0.125 0.131 0.131 0.171 0.171 0.171Strip, store and refit-Insulation and Cladding ft 0.332 0.332 0.332 0.402 0.420 0.420 0.547 0.547 0.547Strip, store and refit-Cladding ft 0.232 0.232 0.232 0.281 0.294 0.294 0.383 0.383 0.383Strip, store and refit-Cladding;remove and renew Insulation ft 0.322 0.322 0.322 0.390 0.408 0.408 0.531 0.531 0.531Extra over Elbow or Bend Nr 0.740 0.740 0.740 0.896 0.936 0.936 1.220 1.220 1.220Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.370 0.370 0.370 0.448 0.468 0.468 0.610 0.610 0.610Extra over Flange Joint-mineral wool Nr 1.056 1.056 1.056 1.281 1.337 1.337 1.743 1.743 1.743Extra over Valve or Strainer-mineral wool Nr 1.585 1.585 1.585 1.921 2.006 2.006 2.615 2.615 2.615Strip, remove and renew Cladding only ft 0.210 0.210 0.210 0.254 0.266 0.266 0.346 0.346 0.346
Unit18" pipe sizeInsulation Thickness
6"4"1" 1 1/2" 2" 2 1/2" 3" 4 1/2" 5" 5 1/2"
193
CALCIUM SILICATE PREFORMED SECTION: UP TO 24 MIL AL UZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
New Complete Specification ft 0.193 0.193 0.193 0.235 0.245 0.245 0.304 0.304 0.304Extra over Elbow or Bend Nr 0.444 0.444 0.444 0.538 0.562 0.562 0.698 0.698 0.698Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.222 0.222 0.222 0.269 0.281 0.281 0.349 0.349 0.349Extra over Flange Joint-mineral wool Nr 0.635 0.635 0.635 0.769 0.803 0.803 0.997 0.997 0.997Extra over Flange Joint-foamglass Nr 0.761 0.761 0.761 0.923 0.964 0.964 1.197 1.197 1.197Extra over Valve or Strainer-mineral wool Nr 0.952 0.952 0.952 1.154 1.205 1.205 1.496 1.496 1.496Extra over Valve or Strainer-foamglass Nr 1.142 1.142 1.142 1.384 1.446 1.446 1.795 1.795 1.795Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.666 0.666 0.666 0.808 0.843 0.843 1.047 1.047 1.047Strip, remove and renew complete specification ft 0.300 0.300 0.300 0.363 0.380 0.380 0.471 0.471 0.471Extra over Elbow or Bend Nr 0.688 0.688 0.688 0.835 0.871 0.871 1.082 1.082 1.082Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.344 0.344 0.344 0.417 0.436 0.436 0.541 0.541 0.541Extra over Flange Joint-mineral wool Nr 0.984 0.984 0.984 1.192 1.245 1.245 1.546 1.546 1.546Extra over Flange Joint-foamglass Nr 1.180 1.180 1.180 1.431 1.494 1.494 1.855 1.855 1.855Extra over Valve or Strainer-mineral wool Nr 1.475 1.475 1.475 1.788 1.867 1.867 2.318 2.318 2.318Extra over Valve or Strainer-foamglass Nr 1.770 1.770 1.770 2.146 2.241 2.241 2.782 2.782 2.782Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.033 1.033 1.033 1.252 1.307 1.307 1.623 1.623 1.623Strip and remove to skip-Insulation and Cladding ft 0.106 0.106 0.106 0.129 0.135 0.135 0.167 0.167 0.167Extra over Elbow or Bend Nr 0.244 0.244 0.244 0.296 0.309 0.309 0.384 0.384 0.384Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.122 0.122 0.122 0.148 0.155 0.155 0.192 0.192 0.192Extra over Flange Joint-mineral wool Nr 0.349 0.349 0.349 0.423 0.442 0.442 0.548 0.548 0.548Extra over Valve or Strainer-mineral wool Nr 0.523 0.523 0.523 0.635 0.663 0.663 0.823 0.823 0.823Strip and remove to skip-Cladding only ft 0.074 0.074 0.074 0.090 0.094 0.094 0.117 0.117 0.117Strip and store-Insulation and Cladding ft 0.148 0.148 0.148 0.179 0.187 0.187 0.233 0.233 0.233Strip and store-Cladding ft 0.103 0.103 0.103 0.125 0.131 0.131 0.163 0.163 0.163Strip, store and refit-Insulation and Cladding ft 0.332 0.332 0.332 0.402 0.420 0.420 0.521 0.521 0.521Strip, store and refit-Cladding ft 0.232 0.232 0.232 0.281 0.294 0.294 0.365 0.365 0.365Strip, store and refit-Cladding;remove and renew Insulation ft 0.322 0.322 0.322 0.390 0.408 0.408 0.506 0.506 0.506Extra over Elbow or Bend Nr 0.740 0.740 0.740 0.896 0.936 0.936 1.162 1.162 1.162Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.370 0.370 0.370 0.448 0.468 0.468 0.581 0.581 0.581Extra over Flange Joint-mineral wool Nr 1.056 1.056 1.056 1.281 1.337 1.337 1.660 1.660 1.660Extra over Valve or Strainer-mineral wool Nr 1.585 1.585 1.585 1.921 2.006 2.006 2.490 2.490 2.490Strip, remove and renew Cladding only ft 0.210 0.210 0.210 0.254 0.266 0.266 0.330 0.330 0.330Extra over Elbow or Bend Nr 0.610Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.305
Unit20" pipe size 1" 1 1/2" 2" 2 1/2" 5 1/2"3" 4" 4 1/2" 5" 6"Insulation Thickness
194
L.2.4 Perlite Preformed Section: up to 24 mil Aluzi nc or Aluminium Flat Rolled Casing to Pipework PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR AL UMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.082 0.082 0.082 0.082 0.113 0.119Extra over Elbow or Bend Nr 0.189 0.189 0.189 0.189 0.260 0.272Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.095 0.095 0.095 0.095 0.130 0.136Extra over Flange Joint-mineral wool Nr 0.270 0.270 0.270 0.270 0.372 0.389Extra over Flange Joint-foamglass Nr 0.324 0.324 0.324 0.324 0.447 0.467Extra over Valve or Strainer-mineral wool Nr 0.406 0.406 0.406 0.406 0.558 0.584Extra over Valve or Strainer-foamglass Nr 0.487 0.487 0.487 0.487 0.670 0.700Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.284 0.284 0.284 0.284 0.391 0.409Strip, remove and renew complete specification ft 0.128 0.128 0.128 0.128 0.176 0.184Extra over Elbow or Bend Nr 0.293 0.293 0.293 0.293 0.404 0.422Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.147 0.147 0.147 0.147 0.202 0.211Extra over Flange Joint-mineral wool Nr 0.419 0.419 0.419 0.419 0.577 0.603Extra over Flange Joint-foamglass Nr 0.503 0.503 0.503 0.503 0.692 0.724Extra over Valve or Strainer-mineral wool Nr 0.629 0.629 0.629 0.629 0.865 0.905Extra over Valve or Strainer-foamglass Nr 0.754 0.754 0.754 0.754 1.038 1.086Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.440 0.440 0.440 0.440 0.606 0.633Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045 0.045 0.062 0.065Extra over Elbow or Bend Nr 0.104 0.104 0.104 0.104 0.143 0.150Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.052 0.052 0.052 0.052 0.072 0.075Extra over Flange Joint-mineral wool or Foamglass Nr 0.149 0.149 0.149 0.149 0.205 0.214Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.223 0.223 0.223 0.223 0.307 0.321Strip and remove to skip-Cladding only ft 0.032 0.032 0.032 0.032 0.044 0.046Strip and store-Insulation and Cladding ft 0.063 0.063 0.063 0.063 0.087 0.091Strip and store-Cladding ft 0.044 0.044 0.044 0.044 0.061 0.063Strip, store and refit-Insulation and Cladding ft 0.141 0.141 0.141 0.141 0.195 0.203Strip, store and refit-Cladding ft 0.099 0.099 0.099 0.099 0.136 0.142Strip, store and refit-Cladding;remove and renew Insulation ft 0.137 0.137 0.137 0.137 0.189 0.198Extra over Elbow or Bend Nr 0.315 0.315 0.315 0.315 0.434 0.453Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.158 0.158 0.158 0.158 0.217 0.227Extra over Flange Joint-mineral wool Nr 0.450 0.450 0.450 0.450 0.620 0.648Extra over Valve or Strainer-mineral wool Nr 0.675 0.675 0.675 0.675 0.929 0.972Strip, remove and renew Cladding only ft 0.089 0.089 0.089 0.089 0.123 0.129
1/2" pipe size Unit 3" 4."Insulation Thickness
1" 1 1/2" 2" 2 1/2"
195
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.082 0.082 0.082 0.082 0.113 0.119Extra over Elbow or Bend Nr 0.189 0.189 0.189 0.189 0.260 0.272Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.095 0.095 0.095 0.095 0.130 0.136Extra over Flange Joint-mineral wool Nr 0.270 0.270 0.270 0.270 0.372 0.389Extra over Flange Joint-foamglass Nr 0.324 0.324 0.324 0.324 0.447 0.467Extra over Valve or Strainer-mineral wool Nr 0.406 0.406 0.406 0.406 0.558 0.584Extra over Valve or Strainer-foamglass Nr 0.487 0.487 0.487 0.487 0.670 0.700Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.284 0.284 0.284 0.284 0.391 0.409Strip, remove and renew complete specification ft 0.128 0.128 0.128 0.128 0.176 0.184Extra over Elbow or Bend Nr 0.293 0.293 0.293 0.293 0.404 0.422Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.147 0.147 0.147 0.147 0.202 0.211Extra over Flange Joint-mineral wool Nr 0.419 0.419 0.419 0.419 0.577 0.603Extra over Flange Joint-foamglass Nr 0.503 0.503 0.503 0.503 0.692 0.724Extra over Valve or Strainer-mineral wool Nr 0.629 0.629 0.629 0.629 0.865 0.905Extra over Valve or Strainer-foamglass Nr 0.754 0.754 0.754 0.754 1.038 1.086Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.440 0.440 0.440 0.440 0.606 0.633Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045 0.045 0.062 0.065Extra over Elbow or Bend Nr 0.104 0.104 0.104 0.104 0.143 0.150Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.052 0.052 0.052 0.052 0.072 0.075Extra over Flange Joint-mineral wool or Foamglass Nr 0.149 0.149 0.149 0.149 0.205 0.214Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.223 0.223 0.223 0.223 0.307 0.321Strip and remove to skip-Cladding only ft 0.032 0.032 0.032 0.032 0.044 0.046Strip and store-Insulation and Cladding ft 0.063 0.063 0.063 0.063 0.087 0.091Strip and store-Cladding ft 0.044 0.044 0.044 0.044 0.061 0.063Strip, store and refit-Insulation and Cladding ft 0.141 0.141 0.141 0.141 0.195 0.203Strip, store and refit-Cladding ft 0.099 0.099 0.099 0.099 0.136 0.142Strip, store and refit-Cladding;remove and renew Insulation ft 0.137 0.137 0.137 0.137 0.189 0.198Extra over Elbow or Bend Nr 0.315 0.315 0.315 0.315 0.434 0.453Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.158 0.158 0.158 0.158 0.217 0.227Extra over Flange Joint-mineral wool Nr 0.450 0.450 0.450 0.450 0.620 0.648Extra over Valve or Strainer-mineral wool Nr 0.675 0.675 0.675 0.675 0.929 0.972Strip, remove and renew Cladding only ft 0.089 0.089 0.089 0.089 0.123 0.129
3/4" pipe size Unit 1" 1 1/2" 2" 2 1/2" 3" 4."Insulation Thickness
196
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.082 0.082 0.082 0.082 0.113 0.119Extra over Elbow or Bend Nr 0.189 0.189 0.189 0.189 0.260 0.272Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.095 0.095 0.095 0.095 0.130 0.136Extra over Flange Joint-mineral wool Nr 0.270 0.270 0.270 0.270 0.372 0.389Extra over Flange Joint-foamglass Nr 0.324 0.324 0.324 0.324 0.447 0.467Extra over Valve or Strainer-mineral wool Nr 0.406 0.406 0.406 0.406 0.558 0.584Extra over Valve or Strainer-foamglass Nr 0.487 0.487 0.487 0.487 0.670 0.700Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.284 0.284 0.284 0.284 0.391 0.409Strip, remove and renew complete specification ft 0.128 0.128 0.128 0.128 0.176 0.184Extra over Elbow or Bend Nr 0.293 0.293 0.293 0.293 0.404 0.422Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.147 0.147 0.147 0.147 0.202 0.211Extra over Flange Joint-mineral wool Nr 0.419 0.419 0.419 0.419 0.577 0.603Extra over Flange Joint-foamglass Nr 0.503 0.503 0.503 0.503 0.692 0.724Extra over Valve or Strainer-mineral wool Nr 0.629 0.629 0.629 0.629 0.865 0.905Extra over Valve or Strainer-foamglass Nr 0.754 0.754 0.754 0.754 1.038 1.086Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.440 0.440 0.440 0.440 0.606 0.633Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045 0.045 0.062 0.065Extra over Elbow or Bend Nr 0.104 0.104 0.104 0.104 0.143 0.150Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.052 0.052 0.052 0.052 0.072 0.075Extra over Flange Joint-mineral wool or Foamglass Nr 0.149 0.149 0.149 0.149 0.205 0.214Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.223 0.223 0.223 0.223 0.307 0.321Strip and remove to skip-Cladding only ft 0.032 0.032 0.032 0.032 0.044 0.046Strip and store-Insulation and Cladding ft 0.063 0.063 0.063 0.063 0.087 0.091Strip and store-Cladding ft 0.044 0.044 0.044 0.044 0.061 0.063Strip, store and refit-Insulation and Cladding ft 0.141 0.141 0.141 0.141 0.195 0.203Strip, store and refit-Cladding ft 0.099 0.099 0.099 0.099 0.136 0.142Strip, store and refit-Cladding;remove and renew Insulation ft 0.137 0.137 0.137 0.137 0.189 0.198Extra over Elbow or Bend Nr 0.315 0.315 0.315 0.315 0.434 0.453Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.158 0.158 0.158 0.158 0.217 0.227Extra over Flange Joint-mineral wool Nr 0.450 0.450 0.450 0.450 0.620 0.648Extra over Valve or Strainer-mineral wool Nr 0.675 0.675 0.675 0.675 0.929 0.972Strip, remove and renew Cladding only ft 0.089 0.089 0.089 0.089 0.123 0.129
1" pipe size Unit 3" 4."1" 1 1/2" 2" 2 1/2"Insulation Thickness
197
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.082 0.082 0.082 0.082 0.113 0.119Extra over Elbow or Bend Nr 0.189 0.189 0.189 0.189 0.260 0.272Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.095 0.095 0.095 0.095 0.130 0.136Extra over Flange Joint-mineral wool Nr 0.270 0.270 0.270 0.270 0.372 0.389Extra over Flange Joint-foamglass Nr 0.324 0.324 0.324 0.324 0.447 0.467Extra over Valve or Strainer-mineral wool Nr 0.406 0.406 0.406 0.406 0.558 0.584Extra over Valve or Strainer-foamglass Nr 0.487 0.487 0.487 0.487 0.670 0.700Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.284 0.284 0.284 0.284 0.391 0.409Strip, remove and renew complete specification ft 0.128 0.128 0.128 0.128 0.176 0.184Extra over Elbow or Bend Nr 0.293 0.293 0.293 0.293 0.404 0.422Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.147 0.147 0.147 0.147 0.202 0.211Extra over Flange Joint-mineral wool Nr 0.419 0.419 0.419 0.419 0.577 0.603Extra over Flange Joint-foamglass Nr 0.503 0.503 0.503 0.503 0.692 0.724Extra over Valve or Strainer-mineral wool Nr 0.629 0.629 0.629 0.629 0.865 0.905Extra over Valve or Strainer-foamglass Nr 0.754 0.754 0.754 0.754 1.038 1.086Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.440 0.440 0.440 0.440 0.606 0.633Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045 0.045 0.062 0.065Extra over Elbow or Bend Nr 0.104 0.104 0.104 0.104 0.143 0.150Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.052 0.052 0.052 0.052 0.072 0.075Extra over Flange Joint-mineral wool or Foamglass Nr 0.149 0.149 0.149 0.149 0.205 0.214Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.223 0.223 0.223 0.223 0.307 0.321Strip and remove to skip-Cladding only ft 0.032 0.032 0.032 0.032 0.044 0.046Strip and store-Insulation and Cladding ft 0.063 0.063 0.063 0.063 0.087 0.091Strip and store-Cladding ft 0.044 0.044 0.044 0.044 0.061 0.063Strip, store and refit-Insulation and Cladding ft 0.141 0.141 0.141 0.141 0.195 0.203Strip, store and refit-Cladding ft 0.099 0.099 0.099 0.099 0.136 0.142Strip, store and refit-Cladding;remove and renew Insulation ft 0.137 0.137 0.137 0.137 0.189 0.198Extra over Elbow or Bend Nr 0.315 0.315 0.315 0.315 0.434 0.453Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.158 0.158 0.158 0.158 0.217 0.227Extra over Flange Joint-mineral wool Nr 0.450 0.450 0.450 0.450 0.620 0.648Extra over Valve or Strainer-mineral wool Nr 0.675 0.675 0.675 0.675 0.929 0.972Strip, remove and renew Cladding only ft 0.089 0.089 0.089 0.089 0.123 0.129
1 1/2" pipe size Unit 2 1/2" 3" 4."1" 1 1/2" 2"Insulation Thickness
198
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.082 0.082 0.082 0.082 0.113 0.119Extra over Elbow or Bend Nr 0.189 0.189 0.189 0.189 0.260 0.272Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.095 0.095 0.095 0.095 0.130 0.136Extra over Flange Joint-mineral wool Nr 0.270 0.270 0.270 0.270 0.372 0.389Extra over Flange Joint-foamglass Nr 0.324 0.324 0.324 0.324 0.447 0.467Extra over Valve or Strainer-mineral wool Nr 0.406 0.406 0.406 0.406 0.558 0.584Extra over Valve or Strainer-foamglass Nr 0.487 0.487 0.487 0.487 0.670 0.700Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.284 0.284 0.284 0.284 0.391 0.409Strip, remove and renew complete specification ft 0.128 0.128 0.128 0.128 0.176 0.184Extra over Elbow or Bend Nr 0.293 0.293 0.293 0.293 0.404 0.422Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.147 0.147 0.147 0.147 0.202 0.211Extra over Flange Joint-mineral wool Nr 0.419 0.419 0.419 0.419 0.577 0.603Extra over Flange Joint-foamglass Nr 0.503 0.503 0.503 0.503 0.692 0.724Extra over Valve or Strainer-mineral wool Nr 0.629 0.629 0.629 0.629 0.865 0.905Extra over Valve or Strainer-foamglass Nr 0.754 0.754 0.754 0.754 1.038 1.086Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.440 0.440 0.440 0.440 0.606 0.633Strip and remove to skip-Insulation and Cladding ft 0.045 0.045 0.045 0.045 0.062 0.065Extra over Elbow or Bend Nr 0.104 0.104 0.104 0.104 0.143 0.150Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.052 0.052 0.052 0.052 0.072 0.075Extra over Flange Joint-mineral wool or Foamglass Nr 0.149 0.149 0.149 0.149 0.205 0.214Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.223 0.223 0.223 0.223 0.307 0.321Strip and remove to skip-Cladding only ft 0.032 0.032 0.032 0.032 0.044 0.046Strip and store-Insulation and Cladding ft 0.063 0.063 0.063 0.063 0.087 0.091Strip and store-Cladding ft 0.044 0.044 0.044 0.044 0.061 0.063Strip, store and refit-Insulation and Cladding ft 0.141 0.141 0.141 0.141 0.195 0.203Strip, store and refit-Cladding ft 0.099 0.099 0.099 0.099 0.136 0.142Strip, store and refit-Cladding;remove and renew Insulation ft 0.137 0.137 0.137 0.137 0.189 0.198Extra over Elbow or Bend Nr 0.315 0.315 0.315 0.315 0.434 0.453Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.158 0.158 0.158 0.158 0.217 0.227Extra over Flange Joint-mineral wool Nr 0.450 0.450 0.450 0.450 0.620 0.648Extra over Valve or Strainer-mineral wool Nr 0.675 0.675 0.675 0.675 0.929 0.972Strip, remove and renew Cladding only ft 0.089 0.089 0.089 0.089 0.123 0.129
2" pipe size Unit 1" 1 1/2" 2" 2 1/2"Insulation Thickness
3" 4."
199
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.101 0.101 0.101 0.101 0.126 0.134Extra over Elbow or Bend Nr 0.231 0.231 0.231 0.231 0.290 0.307Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.115 0.115 0.115 0.115 0.145 0.154Extra over Flange Joint-mineral wool Nr 0.330 0.330 0.330 0.330 0.414 0.439Extra over Flange Joint-foamglass Nr 0.396 0.396 0.396 0.396 0.497 0.527Extra over Valve or Strainer-mineral wool Nr 0.495 0.495 0.495 0.495 0.621 0.658Extra over Valve or Strainer-foamglass Nr 0.593 0.593 0.593 0.593 0.745 0.790Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.346 0.346 0.346 0.346 0.435 0.461Strip, remove and renew complete specification ft 0.156 0.156 0.156 0.156 0.196 0.207Extra over Elbow or Bend Nr 0.358 0.358 0.358 0.358 0.449 0.476Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.179 0.179 0.179 0.179 0.225 0.238Extra over Flange Joint-mineral wool Nr 0.511 0.511 0.511 0.511 0.642 0.680Extra over Flange Joint-foamglass Nr 0.613 0.613 0.613 0.613 0.770 0.816Extra over Valve or Strainer-mineral wool Nr 0.767 0.767 0.767 0.767 0.963 1.020Extra over Valve or Strainer-foamglass Nr 0.920 0.920 0.920 0.920 1.155 1.225Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.537 0.537 0.537 0.537 0.674 0.714Strip and remove to skip-Insulation and Cladding ft 0.055 0.055 0.055 0.055 0.069 0.074Extra over Elbow or Bend Nr 0.127 0.127 0.127 0.127 0.159 0.169Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.063 0.063 0.063 0.063 0.080 0.084Extra over Flange Joint-mineral wool or Foamglass Nr 0.181 0.181 0.181 0.181 0.228 0.241Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.272 0.272 0.272 0.272 0.342 0.362Strip and remove to skip-Cladding only ft 0.039 0.039 0.039 0.039 0.049 0.052Strip and store-Insulation and Cladding ft 0.077 0.077 0.077 0.077 0.097 0.102Strip and store-Cladding ft 0.054 0.054 0.054 0.054 0.068 0.072Strip, store and refit-Insulation and Cladding ft 0.172 0.172 0.172 0.172 0.216 0.229Extra over Elbow or Bend Nr 0.396 0.497Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.198 0.249Strip, store and refit-Cladding ft 0.121 0.121 0.121 0.121 0.151 0.161Strip, store and refit-Cladding;remove and renew Insulation ft 0.167 0.167 0.167 0.167 0.210 0.223Extra over Elbow or Bend Nr 0.384 0.384 0.384 0.384 0.483 0.512Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.192 0.192 0.192 0.192 0.241 0.256Extra over Flange Joint-mineral wool Nr 0.549 0.549 0.549 0.549 0.689 0.731Extra over Valve or Strainer-mineral wool Nr 0.823 0.823 0.823 0.823 1.034 1.096Strip, remove and renew Cladding only ft 0.109 0.109 0.109 0.109 0.137 0.145
3" pipe size Unit 1" 1 1/2" 2" 2 1/2" 3" 4."Insulation Thickness
200
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.101 0.101 0.101 0.101 0.126 0.134Extra over Elbow or Bend Nr 0.231 0.231 0.231 0.231 0.290 0.307Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.115 0.115 0.115 0.115 0.145 0.154Extra over Flange Joint-mineral wool Nr 0.330 0.330 0.330 0.330 0.414 0.439Extra over Flange Joint-foamglass Nr 0.396 0.396 0.396 0.396 0.497 0.527Extra over Valve or Strainer-mineral wool Nr 0.495 0.495 0.495 0.495 0.621 0.658Extra over Valve or Strainer-foamglass Nr 0.593 0.593 0.593 0.593 0.745 0.790Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.346 0.346 0.346 0.346 0.435 0.461Strip, remove and renew complete specification ft 0.156 0.156 0.156 0.156 0.196 0.207Extra over Elbow or Bend Nr 0.358 0.358 0.358 0.358 0.449 0.476Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.179 0.179 0.179 0.179 0.225 0.238Extra over Flange Joint-mineral wool Nr 0.511 0.511 0.511 0.511 0.642 0.680Extra over Flange Joint-foamglass Nr 0.613 0.613 0.613 0.613 0.770 0.816Extra over Valve or Strainer-mineral wool Nr 0.767 0.767 0.767 0.767 0.963 1.020Extra over Valve or Strainer-foamglass Nr 0.920 0.920 0.920 0.920 1.155 1.225Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.537 0.537 0.537 0.537 0.674 0.714Strip and remove to skip-Insulation and Cladding ft 0.055 0.055 0.055 0.055 0.069 0.074Extra over Elbow or Bend Nr 0.127 0.127 0.127 0.127 0.159 0.169Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.063 0.063 0.063 0.063 0.080 0.084Extra over Flange Joint-mineral wool or Foamglass Nr 0.181 0.181 0.181 0.181 0.228 0.241Extra over Valve or Strainer-mineral wool or Foamglass Nr 0.272 0.272 0.272 0.272 0.342 0.362Strip and remove to skip-Cladding only ft 0.039 0.039 0.039 0.039 0.049 0.052Strip and store-Insulation and Cladding ft 0.077 0.077 0.077 0.077 0.097 0.102Strip and store-Cladding ft 0.054 0.054 0.054 0.054 0.068 0.072Strip, store and refit-Insulation and Cladding ft 0.172 0.172 0.172 0.172 0.216 0.229Strip, store and refit-Cladding ft 0.121 0.121 0.121 0.121 0.151 0.161Strip, store and refit-Cladding;remove and renew Insulation ft 0.167 0.167 0.167 0.167 0.210 0.223Extra over Elbow or Bend Nr 0.384 0.384 0.384 0.384 0.483 0.512Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.192 0.192 0.192 0.192 0.241 0.256Extra over Flange Joint-mineral wool Nr 0.549 0.549 0.549 0.549 0.689 0.731Extra over Valve or Strainer-mineral wool Nr 0.823 0.823 0.823 0.823 1.034 1.096Strip, remove and renew Cladding only ft 0.109 0.109 0.109 0.109 0.137 0.145
Unit4" pipe size 3" 4."1" 1 1/2" 2" 2 1/2"Insulation Thickness
201
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.101 0.101 0.101 0.101 0.126 0.134 0.134 0.165 0.165 0.165Extra over Elbow or Bend Nr 0.231 0.231 0.231 0.231 0.290 0.307 0.307 0.378 0.378 0.378Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.115 0.115 0.115 0.115 0.145 0.154 0.154 0.189 0.189 0.189Extra over Flange Joint-mineral wool Nr 0.330 0.330 0.330 0.330 0.414 0.439 0.439 0.541 0.541 0.541Extra over Flange Joint-foamglass Nr 0.396 0.396 0.396 0.396 0.497 0.527 0.527 0.649 0.649 0.649Extra over Valve or Strainer-mineral wool Nr 0.495 0.495 0.495 0.495 0.621 0.658 0.658 0.811 0.811 0.811Extra over Valve or Strainer-foamglass Nr 0.593 0.593 0.593 0.593 0.745 0.790 0.790 0.973 0.973 0.973Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.346 0.346 0.346 0.346 0.435 0.461 0.461 0.568 0.568 0.568Strip, remove and renew complete specification ft 0.156 0.156 0.156 0.156 0.196 0.207 0.207 0.256 0.256 0.256Extra over Elbow or Bend Nr 0.358 0.358 0.358 0.358 0.449 0.476 0.476 0.587 0.587 0.587Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.179 0.179 0.179 0.179 0.225 0.238 0.238 0.293 0.293 0.293Extra over Flange Joint-mineral wool Nr 0.511 0.511 0.511 0.511 0.642 0.680 0.680 0.838 0.838 0.838Extra over Flange Joint-foamglass Nr 0.613 0.613 0.613 0.613 0.770 0.816 0.816 1.006 1.006 1.006Extra over Valve or Strainer-mineral wool Nr 0.767 0.767 0.767 0.767 0.963 1.020 1.020 1.257 1.257 1.257Extra over Valve or Strainer-foamglass Nr 0.920 0.920 0.920 0.920 1.155 1.225 1.225 1.509 1.509 1.509Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.537 0.537 0.537 0.537 0.674 0.714 0.714 0.880 0.880 0.880Strip and remove to skip-Insulation and Cladding ft 0.055 0.055 0.055 0.055 0.069 0.074 0.074 0.091 0.091 0.091Extra over Elbow or Bend Nr 0.127 0.127 0.127 0.127 0.159 0.169 0.169 0.208 0.208 0.208Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.063 0.063 0.063 0.063 0.080 0.084 0.084 0.104 0.104 0.104Extra over Flange Joint-mineral wool Nr 0.181 0.181 0.181 0.181 0.228 0.241 0.241 0.297 0.297 0.297Extra over Valve or Strainer-mineral wool Nr 0.272 0.272 0.272 0.272 0.342 0.362 0.362 0.446 0.446 0.446Strip and remove to skip-Cladding only ft 0.039 0.039 0.039 0.039 0.049 0.052 0.052 0.063 0.063 0.063Strip and store-Insulation and Cladding ft 0.077 0.077 0.077 0.077 0.097 0.102 0.102 0.126 0.126 0.126Strip and store-Cladding ft 0.054 0.054 0.054 0.054 0.068 0.072 0.072 0.088 0.088 0.088Strip, store and refit-Insulation and Cladding ft 0.172 0.172 0.172 0.172 0.216 0.229 0.229 0.283 0.283 0.283Strip, store and refit-Cladding ft 0.121 0.121 0.121 0.121 0.151 0.161 0.161 0.198 0.198 0.198Strip, store and refit-Cladding;remove and renew Insulation ft 0.167 0.167 0.167 0.167 0.210 0.223 0.223 0.274 0.274 0.274Extra over Elbow or Bend Nr 0.384 0.384 0.384 0.384 0.483 0.512 0.512 0.630 0.630 0.630Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.192 0.192 0.192 0.192 0.241 0.256 0.256 0.315 0.315 0.315Extra over Flange Joint-mineral wool Nr 0.549 0.549 0.549 0.549 0.689 0.731 0.731 0.900 0.900 0.900Extra over Valve or Strainer-mineral wool Nr 0.823 0.823 0.823 0.823 1.034 1.096 1.096 1.350 1.350 1.350Strip, remove and renew Cladding only ft 0.109 0.109 0.109 0.109 0.137 0.145 0.145 0.179 0.179 0.179Extra over Elbow or Bend Nr 0.250
Unit6" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4" 4 1/2" 5" 5 1/2" 6"
202
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.126 0.126 0.126 0.126 0.160 0.165 0.165 0.209 0.209 0.209Extra over Elbow or Bend Nr 0.290 0.290 0.290 0.290 0.367 0.378 0.378 0.479 0.479 0.479Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.145 0.145 0.145 0.145 0.183 0.189 0.189 0.240 0.240 0.240Extra over Flange Joint-mineral wool Nr 0.414 0.414 0.414 0.414 0.524 0.541 0.541 0.684 0.684 0.684Extra over Flange Joint-foamglass Nr 0.497 0.497 0.497 0.497 0.628 0.649 0.649 0.821 0.821 0.821Extra over Valve or Strainer-mineral wool Nr 0.621 0.621 0.621 0.621 0.786 0.811 0.811 1.027 1.027 1.027Extra over Valve or Strainer-foamglass Nr 0.745 0.745 0.745 0.745 0.943 0.973 0.973 1.232 1.232 1.232Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.435 0.435 0.435 0.435 0.550 0.568 0.568 0.719 0.719 0.719Strip, remove and renew complete specification ft 0.196 0.196 0.196 0.196 0.247 0.256 0.256 0.323 0.323 0.323Extra over Elbow or Bend Nr 0.449 0.449 0.449 0.449 0.568 0.587 0.587 0.743 0.743 0.743Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.225 0.225 0.225 0.225 0.284 0.293 0.293 0.371 0.371 0.371Extra over Flange Joint-mineral wool Nr 0.642 0.642 0.642 0.642 0.812 0.838 0.838 1.061 1.061 1.061Extra over Flange Joint-foamglass Nr 0.770 0.770 0.770 0.770 0.974 1.006 1.006 1.273 1.273 1.273Extra over Valve or Strainer-mineral wool Nr 0.963 0.963 0.963 0.963 1.218 1.257 1.257 1.591 1.591 1.591Extra over Valve or Strainer-foamglass Nr 1.155 1.155 1.155 1.155 1.461 1.509 1.509 1.909 1.909 1.909Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.674 0.674 0.674 0.674 0.852 0.880 0.880 1.114 1.114 1.114Strip and remove to skip-Insulation and Cladding ft 0.069 0.069 0.069 0.069 0.088 0.091 0.091 0.115 0.115 0.115Extra over Elbow or Bend Nr 0.159 0.159 0.159 0.159 0.202 0.208 0.208 0.263 0.263 0.263Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.080 0.080 0.080 0.080 0.101 0.104 0.104 0.132 0.132 0.132Extra over Flange Joint-mineral wool Nr 0.228 0.228 0.228 0.228 0.288 0.297 0.297 0.376 0.376 0.376Extra over Valve or Strainer-mineral wool Nr 0.342 0.342 0.342 0.342 0.432 0.446 0.446 0.565 0.565 0.565Strip and remove to skip-Cladding only ft 0.049 0.049 0.049 0.049 0.061 0.063 0.063 0.080 0.080 0.080Strip and store-Insulation and Cladding ft 0.097 0.097 0.097 0.097 0.122 0.126 0.126 0.160 0.160 0.160Strip and store-Cladding ft 0.068 0.068 0.068 0.068 0.085 0.088 0.088 0.112 0.112 0.112Strip, store and refit-Insulation and Cladding ft 0.216 0.216 0.216 0.216 0.274 0.283 0.283 0.358 0.358 0.358Strip, store and refit-Cladding ft 0.151 0.151 0.151 0.151 0.192 0.198 0.198 0.250 0.250 0.250Strip, store and refit-Cladding;remove and renew Insulation ft 0.210 0.210 0.210 0.210 0.266 0.274 0.274 0.347 0.347 0.347Extra over Elbow or Bend Nr 0.483 0.483 0.483 0.483 0.610 0.630 0.630 0.798 0.798 0.798Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.241 0.241 0.241 0.241 0.305 0.315 0.315 0.399 0.399 0.399Extra over Flange Joint-mineral wool Nr 0.689 0.689 0.689 0.689 0.872 0.900 0.900 1.139 1.139 1.139Extra over Valve or Strainer-mineral wool Nr 1.034 1.034 1.034 1.034 1.308 1.350 1.350 1.709 1.709 1.709Strip, remove and renew Cladding only ft 0.137 0.137 0.137 0.137 0.173 0.179 0.179 0.226 0.226 0.226Extra over Elbow or Bend Nr 0.314
8" pipe size UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 4" 4 1/2" 5" 5 1/2" 6"
203
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.126 0.126 0.126 0.126 0.162 0.168 0.168 0.211 0.211 0.211Extra over Elbow or Bend Nr 0.290 0.290 0.290 0.290 0.373 0.385 0.385 0.485 0.485 0.485Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.145 0.145 0.145 0.145 0.186 0.192 0.192 0.242 0.242 0.242Extra over Flange Joint-mineral wool Nr 0.414 0.414 0.414 0.414 0.533 0.550 0.550 0.693 0.693 0.693Extra over Flange Joint-foamglass Nr 0.497 0.497 0.497 0.497 0.639 0.660 0.660 0.831 0.831 0.831Extra over Valve or Strainer-mineral wool Nr 0.621 0.621 0.621 0.621 0.799 0.825 0.825 1.039 1.039 1.039Extra over Valve or Strainer-foamglass Nr 0.745 0.745 0.745 0.745 0.959 0.989 0.989 1.247 1.247 1.247Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.435 0.435 0.435 0.435 0.559 0.577 0.577 0.727 0.727 0.727Strip, remove and renew complete specification ft 0.196 0.196 0.196 0.196 0.252 0.260 0.260 0.327 0.327 0.327Extra over Elbow or Bend Nr 0.449 0.449 0.449 0.449 0.578 0.596 0.596 0.752 0.752 0.752Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.225 0.225 0.225 0.225 0.289 0.298 0.298 0.376 0.376 0.376Extra over Flange Joint-mineral wool Nr 0.642 0.642 0.642 0.642 0.826 0.852 0.852 1.074 1.074 1.074Extra over Flange Joint-foamglass Nr 0.770 0.770 0.770 0.770 0.991 1.022 1.022 1.289 1.289 1.289Extra over Valve or Strainer-mineral wool Nr 0.963 0.963 0.963 0.963 1.239 1.278 1.278 1.611 1.611 1.611Extra over Valve or Strainer-foamglass Nr 1.155 1.155 1.155 1.155 1.486 1.534 1.534 1.933 1.933 1.933Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.674 0.674 0.674 0.674 0.867 0.895 0.895 1.128 1.128 1.128Strip and remove to skip-Insulation and Cladding ft 0.069 0.069 0.069 0.069 0.089 0.092 0.092 0.116 0.116 0.116Extra over Elbow or Bend Nr 0.159 0.159 0.159 0.159 0.205 0.212 0.212 0.267 0.267 0.267Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.080 0.080 0.080 0.080 0.103 0.106 0.106 0.133 0.133 0.133Extra over Flange Joint-mineral wool Nr 0.228 0.228 0.228 0.228 0.293 0.302 0.302 0.381 0.381 0.381Extra over Valve or Strainer-mineral wool Nr 0.342 0.342 0.342 0.342 0.440 0.454 0.454 0.572 0.572 0.572Strip and remove to skip-Cladding only ft 0.049 0.049 0.049 0.049 0.063 0.065 0.065 0.081 0.081 0.081Strip and store-Insulation and Cladding ft 0.097 0.097 0.097 0.097 0.124 0.128 0.128 0.162 0.162 0.162Strip and store-Cladding ft 0.068 0.068 0.068 0.068 0.087 0.090 0.090 0.113 0.113 0.113Strip, store and refit-Insulation and Cladding ft 0.216 0.216 0.216 0.216 0.279 0.287 0.287 0.362 0.362 0.362Strip, store and refit-Cladding ft 0.151 0.151 0.151 0.151 0.195 0.201 0.201 0.253 0.253 0.253Strip, store and refit-Cladding;remove and renew Insulation ft 0.210 0.210 0.210 0.210 0.270 0.279 0.279 0.352 0.352 0.352Extra over Elbow or Bend Nr 0.483 0.483 0.483 0.483 0.621 0.641 0.641 0.807 0.807 0.807Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.241 0.241 0.241 0.241 0.310 0.320 0.320 0.404 0.404 0.404Extra over Flange Joint-mineral wool Nr 0.689 0.689 0.689 0.689 0.887 0.915 0.915 1.154 1.154 1.154Extra over Valve or Strainer-mineral wool Nr 1.034 1.034 1.034 1.034 1.331 1.373 1.373 1.730 1.730 1.730Strip, remove and renew Cladding only ft 0.137 0.137 0.137 0.137 0.176 0.182 0.182 0.229 0.229 0.229EO Tee, Reducer, Full Cap End or End Closure Plate Nr 0.157
Unit10" pipe size 5 1/2" 6"Insulation Thickness
1" 1 1/2" 2" 2 1/2" 5"3" 4" 4 1/2"
204
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.162 0.162 0.162 0.162 0.204 0.211 0.211 0.263 0.263 0.263Extra over Elbow or Bend Nr 0.373 0.373 0.373 0.373 0.468 0.485 0.485 0.603 0.603 0.603Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.186 0.186 0.186 0.186 0.234 0.242 0.242 0.302 0.302 0.302Extra over Flange Joint-mineral wool Nr 0.533 0.533 0.533 0.533 0.668 0.693 0.693 0.862 0.862 0.862Extra over Flange Joint-foamglass Nr 0.639 0.639 0.639 0.639 0.802 0.831 0.831 1.034 1.034 1.034Extra over Valve or Strainer-mineral wool Nr 0.799 0.799 0.799 0.799 1.002 1.039 1.039 1.293 1.293 1.293Extra over Valve or Strainer-foamglass Nr 0.959 0.959 0.959 0.959 1.202 1.247 1.247 1.551 1.551 1.551Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.559 0.559 0.559 0.559 0.701 0.727 0.727 0.905 0.905 0.905Strip, remove and renew complete specification ft 0.252 0.252 0.252 0.252 0.316 0.327 0.327 0.407 0.407 0.407Extra over Elbow or Bend Nr 0.578 0.578 0.578 0.578 0.725 0.752 0.752 0.935 0.935 0.935Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.289 0.289 0.289 0.289 0.362 0.376 0.376 0.468 0.468 0.468Extra over Flange Joint-mineral wool Nr 0.826 0.826 0.826 0.826 1.035 1.074 1.074 1.336 1.336 1.336Extra over Flange Joint-foamglass Nr 0.991 0.991 0.991 0.991 1.242 1.289 1.289 1.603 1.603 1.603Extra over Valve or Strainer-mineral wool Nr 1.239 1.239 1.239 1.239 1.553 1.611 1.611 2.004 2.004 2.004Extra over Valve or Strainer-foamglass Nr 1.486 1.486 1.486 1.486 1.863 1.933 1.933 2.405 2.405 2.405Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.867 0.867 0.867 0.867 1.087 1.128 1.128 1.403 1.403 1.403Strip and remove to skip-Insulation and Cladding ft 0.089 0.089 0.089 0.089 0.112 0.116 0.116 0.145 0.145 0.145Extra over Elbow or Bend Nr 0.205 0.205 0.205 0.205 0.257 0.267 0.267 0.332 0.332 0.332Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.103 0.103 0.103 0.103 0.129 0.133 0.133 0.166 0.166 0.166Extra over Flange Joint-mineral wool Nr 0.293 0.293 0.293 0.293 0.367 0.381 0.381 0.474 0.474 0.474Extra over Valve or Strainer-mineral wool Nr 0.440 0.440 0.440 0.440 0.551 0.572 0.572 0.711 0.711 0.711Strip and remove to skip-Cladding only ft 0.063 0.063 0.063 0.063 0.078 0.081 0.081 0.101 0.101 0.101Extra over Elbow or Bend Nr 0.187Extra over Flange Joint-mineral wool Nr 0.267Strip and store-Insulation and Cladding ft 0.124 0.124 0.124 0.124 0.156 0.162 0.162 0.201 0.201 0.201Strip and store-Cladding ft 0.087 0.087 0.087 0.087 0.109 0.113 0.113 0.141 0.141 0.141Strip, store and refit-Insulation and Cladding ft 0.279 0.279 0.279 0.279 0.349 0.362 0.362 0.451 0.451 0.451Strip, store and refit-Cladding ft 0.195 0.195 0.195 0.195 0.244 0.253 0.253 0.315 0.315 0.315Strip, store and refit-Cladding;remove and renew Insulation ft 0.270 0.270 0.270 0.270 0.339 0.352 0.352 0.438 0.438 0.438Extra over Elbow or Bend Nr 0.621 0.621 0.621 0.621 0.778 0.807 0.807 1.005 1.005 1.005Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.310 0.310 0.310 0.310 0.389 0.404 0.404 0.502 0.502 0.502Extra over Flange Joint-mineral wool Nr 0.887 0.887 0.887 0.887 1.112 1.154 1.154 1.435 1.435 1.435Extra over Valve or Strainer-mineral wool Nr 1.331 1.331 1.331 1.331 1.668 1.730 1.730 2.153 2.153 2.153Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.931Strip, remove and renew Cladding only ft 0.176 0.176 0.176 0.176 0.221 0.229 0.229 0.285 0.285 0.285Extra over Elbow or Bend Nr 0.405 0.507 0.526Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.263Extra over Flange Joint-mineral wool Nr 0.752Extra over Valve or Strainer-mineral wool Nr 1.128
12" pipe size UnitInsulation Thickness
5"1" 1 1/2" 2" 2 1/2" 3" 4" 4 1/2" 5 1/2" 6"
205
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.162 0.162 0.162 0.204 0.211 0.211 0.263 0.263 0.263Extra over Elbow or Bend Nr 0.373 0.373 0.373 0.468 0.485 0.485 0.603 0.603 0.603Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.186 0.186 0.186 0.234 0.242 0.242 0.302 0.302 0.302Extra over Flange Joint-mineral wool Nr 0.533 0.533 0.533 0.668 0.693 0.693 0.862 0.862 0.862Extra over Flange Joint-foamglass Nr 0.639 0.639 0.639 0.802 0.831 0.831 1.034 1.034 1.034Extra over Valve or Strainer-mineral wool Nr 0.799 0.799 0.799 1.002 1.039 1.039 1.293 1.293 1.293Extra over Valve or Strainer-foamglass Nr 0.959 0.959 0.959 1.202 1.247 1.247 1.551 1.551 1.551Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.559 0.559 0.559 0.701 0.727 0.727 0.905 0.905 0.905Strip, remove and renew complete specification ft 0.252 0.252 0.252 0.316 0.327 0.327 0.407 0.407 0.407Extra over Elbow or Bend Nr 0.578 0.578 0.578 0.725 0.752 0.752 0.935 0.935 0.935Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.289 0.289 0.289 0.362 0.376 0.376 0.468 0.468 0.468Extra over Flange Joint-mineral wool Nr 0.826 0.826 0.826 1.035 1.074 1.074 1.336 1.336 1.336Extra over Flange Joint-foamglass Nr 0.991 0.991 0.991 1.242 1.289 1.289 1.603 1.603 1.603Extra over Valve or Strainer-mineral wool Nr 1.239 1.239 1.239 1.553 1.611 1.611 2.004 2.004 2.004Extra over Valve or Strainer-foamglass Nr 1.486 1.486 1.486 1.863 1.933 1.933 2.405 2.405 2.405Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.867 0.867 0.867 1.087 1.128 1.128 1.403 1.403 1.403Strip and remove to skip-Insulation and Cladding ft 0.089 0.089 0.089 0.112 0.116 0.116 0.145 0.145 0.145Extra over Elbow or Bend Nr 0.205 0.205 0.205 0.257 0.267 0.267 0.332 0.332 0.332Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.103 0.103 0.103 0.129 0.133 0.133 0.166 0.166 0.166Extra over Flange Joint-mineral wool Nr 0.293 0.293 0.293 0.367 0.381 0.381 0.474 0.474 0.474Extra over Valve or Strainer-mineral wool Nr 0.440 0.440 0.440 0.551 0.572 0.572 0.711 0.711 0.711Strip and remove to skip-Cladding only ft 0.063 0.063 0.063 0.078 0.081 0.081 0.101 0.101 0.101Strip and store-Insulation and Cladding ft 0.124 0.124 0.124 0.156 0.162 0.162 0.201 0.201 0.201Strip and store-Cladding ft 0.087 0.087 0.087 0.109 0.113 0.113 0.141 0.141 0.141Strip, store and refit-Insulation and Cladding ft 0.279 0.279 0.279 0.349 0.362 0.362 0.451 0.451 0.451Strip, store and refit-Cladding ft 0.195 0.195 0.195 0.244 0.253 0.253 0.315 0.315 0.315Strip, store and refit-Cladding;remove and renew Insulation ft 0.270 0.270 0.270 0.339 0.352 0.352 0.438 0.438 0.438Extra over Elbow or Bend Nr 0.621 0.621 0.621 0.778 0.807 0.807 1.005 1.005 1.005Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.310 0.310 0.310 0.389 0.404 0.404 0.502 0.502 0.502Extra over Flange Joint-mineral wool Nr 0.887 0.887 0.887 1.112 1.154 1.154 1.435 1.435 1.435Extra over Valve or Strainer-mineral wool Nr 1.331 1.331 1.331 1.668 1.730 1.730 2.153 2.153 2.153Strip, remove and renew Cladding only ft 0.176 0.176 0.176 0.221 0.229 0.229 0.285 0.285 0.285
Unit14" pipe size 2 1/2" 3" 4" 4 1/2" 5" 5 1/2" 6"Insulation Thickness
1" 1 1/2" 2"
206
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.193 0.193 0.193 0.235 0.245 0.245 0.304 0.304 0.304Extra over Elbow or Bend Nr 0.444 0.444 0.444 0.538 0.562 0.562 0.698 0.698 0.698Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.222 0.222 0.222 0.269 0.281 0.281 0.349 0.349 0.349Extra over Flange Joint-mineral wool Nr 0.635 0.635 0.635 0.769 0.803 0.803 0.997 0.997 0.997Extra over Flange Joint-foamglass Nr 0.761 0.761 0.761 0.923 0.964 0.964 1.197 1.197 1.197Extra over Valve or Strainer-mineral wool Nr 0.952 0.952 0.952 1.154 1.205 1.205 1.496 1.496 1.496Extra over Valve or Strainer-foamglass Nr 1.142 1.142 1.142 1.384 1.446 1.446 1.795 1.795 1.795Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.666 0.666 0.666 0.808 0.843 0.843 1.047 1.047 1.047Strip, remove and renew complete specification ft 0.300 0.300 0.300 0.363 0.380 0.380 0.471 0.471 0.471Extra over Elbow or Bend Nr 0.688 0.688 0.688 0.835 0.871 0.871 1.082 1.082 1.082Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.344 0.344 0.344 0.417 0.436 0.436 0.541 0.541 0.541Extra over Flange Joint-mineral wool Nr 0.984 0.984 0.984 1.192 1.245 1.245 1.546 1.546 1.546Extra over Flange Joint-foamglass Nr 1.180 1.180 1.180 1.431 1.494 1.494 1.855 1.855 1.855Extra over Valve or Strainer-mineral wool Nr 1.475 1.475 1.475 1.788 1.867 1.867 2.318 2.318 2.318Extra over Valve or Strainer-foamglass Nr 1.770 1.770 1.770 2.146 2.241 2.241 2.782 2.782 2.782Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.033 1.033 1.033 1.252 1.307 1.307 1.623 1.623 1.623Strip and remove to skip-Insulation and Cladding ft 0.106 0.106 0.106 0.129 0.135 0.135 0.167 0.167 0.167Extra over Elbow or Bend Nr 0.244 0.244 0.244 0.296 0.309 0.309 0.384 0.384 0.384Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.122 0.122 0.122 0.148 0.155 0.155 0.192 0.192 0.192Extra over Flange Joint-mineral wool Nr 0.349 0.349 0.349 0.423 0.442 0.442 0.548 0.548 0.548Extra over Valve or Strainer-mineral wool Nr 0.523 0.523 0.523 0.635 0.663 0.663 0.823 0.823 0.823Strip and remove to skip-Cladding only ft 0.074 0.074 0.074 0.090 0.094 0.094 0.117 0.117 0.117Strip and store-Insulation and Cladding ft 0.148 0.148 0.148 0.179 0.187 0.187 0.233 0.233 0.233Strip and store-Cladding ft 0.103 0.103 0.103 0.125 0.131 0.131 0.163 0.163 0.163Strip, store and refit-Insulation and Cladding ft 0.332 0.332 0.332 0.402 0.420 0.420 0.521 0.521 0.521Strip, store and refit-Cladding ft 0.232 0.232 0.232 0.281 0.294 0.294 0.365 0.365 0.365Strip, store and refit-Cladding;remove and renew Insulation ft 0.322 0.322 0.322 0.390 0.408 0.408 0.506 0.506 0.506Extra over Elbow or Bend Nr 0.740 0.740 0.740 0.896 0.936 0.936 1.162 1.162 1.162Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.370 0.370 0.370 0.448 0.468 0.468 0.581 0.581 0.581Extra over Flange Joint-mineral wool Nr 1.056 1.056 1.056 1.281 1.337 1.337 1.660 1.660 1.660Extra over Valve or Strainer-mineral wool Nr 1.585 1.585 1.585 1.921 2.006 2.006 2.490 2.490 2.490Strip, remove and renew Cladding only ft 0.210 0.210 0.210 0.254 0.266 0.266 0.330 0.330 0.330
Unit16" pipe sizeInsulation Thickness
3" 4" 4 1/2" 5"1" 1 1/2" 2" 2 1/2" 5 1/2" 6"
207
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.193 0.193 0.193 0.235 0.245 0.245 0.319 0.319 0.319Extra over Elbow or Bend Nr 0.444 0.444 0.444 0.538 0.562 0.562 0.733 0.733 0.733Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.222 0.222 0.222 0.269 0.281 0.281 0.366 0.366 0.366Extra over Flange Joint-mineral wool Nr 0.635 0.635 0.635 0.769 0.803 0.803 1.047 1.047 1.047Extra over Flange Joint-foamglass Nr 0.761 0.761 0.761 0.923 0.964 0.964 1.256 1.256 1.256Extra over Valve or Strainer-mineral wool Nr 0.952 0.952 0.952 1.154 1.205 1.205 1.570 1.570 1.570Extra over Valve or Strainer-foamglass Nr 1.142 1.142 1.142 1.384 1.446 1.446 1.884 1.884 1.884Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.666 0.666 0.666 0.808 0.843 0.843 1.099 1.099 1.099Strip, remove and renew complete specification ft 0.300 0.300 0.300 0.363 0.380 0.380 0.495 0.495 0.495Extra over Elbow or Bend Nr 0.688 0.688 0.688 0.835 0.871 0.871 1.136 1.136 1.136Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.344 0.344 0.344 0.417 0.436 0.436 0.568 0.568 0.568Extra over Flange Joint-mineral wool Nr 0.984 0.984 0.984 1.192 1.245 1.245 1.623 1.623 1.623Extra over Flange Joint-foamglass Nr 1.180 1.180 1.180 1.431 1.494 1.494 1.947 1.947 1.947Extra over Valve or Strainer-mineral wool Nr 1.475 1.475 1.475 1.788 1.867 1.867 2.434 2.434 2.434Extra over Valve or Strainer-foamglass Nr 1.770 1.770 1.770 2.146 2.241 2.241 2.921 2.921 2.921Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.033 1.033 1.033 1.252 1.307 1.307 1.704 1.704 1.704Strip and remove to skip-Insulation and Cladding ft 0.106 0.106 0.106 0.129 0.135 0.135 0.176 0.176 0.176Extra over Elbow or Bend Nr 0.244 0.244 0.244 0.296 0.309 0.309 0.403 0.403 0.403Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.122 0.122 0.122 0.148 0.155 0.155 0.202 0.202 0.202Extra over Flange Joint-mineral wool Nr 0.349 0.349 0.349 0.423 0.442 0.442 0.576 0.576 0.576Extra over Valve or Strainer-mineral wool Nr 0.523 0.523 0.523 0.635 0.663 0.663 0.864 0.864 0.864Strip and remove to skip-Cladding only ft 0.074 0.074 0.074 0.090 0.094 0.094 0.123 0.123 0.123Strip and store-Insulation and Cladding ft 0.148 0.148 0.148 0.179 0.187 0.187 0.244 0.244 0.244Strip and store-Cladding ft 0.103 0.103 0.103 0.125 0.131 0.131 0.171 0.171 0.171Strip, store and refit-Insulation and Cladding ft 0.332 0.332 0.332 0.402 0.420 0.420 0.547 0.547 0.547Strip, store and refit-Cladding ft 0.232 0.232 0.232 0.281 0.294 0.294 0.383 0.383 0.383Strip, store and refit-Cladding;remove and renew Insulation ft 0.322 0.322 0.322 0.390 0.408 0.408 0.531 0.531 0.531Extra over Elbow or Bend Nr 0.740 0.740 0.740 0.896 0.936 0.936 1.220 1.220 1.220Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.370 0.370 0.370 0.448 0.468 0.468 0.610 0.610 0.610Extra over Flange Joint-mineral wool Nr 1.056 1.056 1.056 1.281 1.337 1.337 1.743 1.743 1.743Extra over Valve or Strainer-mineral wool Nr 1.585 1.585 1.585 1.921 2.006 2.006 2.615 2.615 2.615Strip, remove and renew Cladding only ft 0.210 0.210 0.210 0.254 0.266 0.266 0.346 0.346 0.346
18" pipe size Unit 6"Insulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 5" 5 1/2"4" 4 1/2"
208
PERLITE PREFORMED SECTION: UP TO 24 MIL ALUZINC OR ALUMINIUM FLATROLLED CASING TO PIPEWORK
Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft 0.193 0.193 0.193 0.235 0.245 0.245 0.304 0.304 0.304Extra over Elbow or Bend Nr 0.444 0.444 0.444 0.538 0.562 0.562 0.698 0.698 0.698Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.222 0.222 0.222 0.269 0.281 0.281 0.349 0.349 0.349Extra over Flange Joint-mineral wool Nr 0.635 0.635 0.635 0.769 0.803 0.803 0.997 0.997 0.997Extra over Flange Joint-foamglass Nr 0.761 0.761 0.761 0.923 0.964 0.964 1.197 1.197 1.197Extra over Valve or Strainer-mineral wool Nr 0.952 0.952 0.952 1.154 1.205 1.205 1.496 1.496 1.496Extra over Valve or Strainer-foamglass Nr 1.142 1.142 1.142 1.384 1.446 1.446 1.795 1.795 1.795Extra over Seal Closure Plate with Armourset and Rockwrap Nr 0.666 0.666 0.666 0.808 0.843 0.843 1.047 1.047 1.047Strip, remove and renew complete specification ft 0.300 0.300 0.300 0.363 0.380 0.380 0.471 0.471 0.471Extra over Elbow or Bend Nr 0.688 0.688 0.688 0.835 0.871 0.871 1.082 1.082 1.082Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.344 0.344 0.344 0.417 0.436 0.436 0.541 0.541 0.541Extra over Flange Joint-mineral wool Nr 0.984 0.984 0.984 1.192 1.245 1.245 1.546 1.546 1.546Extra over Flange Joint-foamglass Nr 1.180 1.180 1.180 1.431 1.494 1.494 1.855 1.855 1.855Extra over Valve or Strainer-mineral wool Nr 1.475 1.475 1.475 1.788 1.867 1.867 2.318 2.318 2.318Extra over Valve or Strainer-foamglass Nr 1.770 1.770 1.770 2.146 2.241 2.241 2.782 2.782 2.782Extra over Seal Closure Plate with Armourset and Rockwrap Nr 1.033 1.033 1.033 1.252 1.307 1.307 1.623 1.623 1.623Strip and remove to skip-Insulation and Cladding ft 0.106 0.106 0.106 0.129 0.135 0.135 0.167 0.167 0.167Extra over Elbow or Bend Nr 0.244 0.244 0.244 0.296 0.309 0.309 0.384 0.384 0.384Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.122 0.122 0.122 0.148 0.155 0.155 0.192 0.192 0.192Extra over Flange Joint-mineral wool Nr 0.349 0.349 0.349 0.423 0.442 0.442 0.548 0.548 0.548Extra over Valve or Strainer-mineral wool Nr 0.523 0.523 0.523 0.635 0.663 0.663 0.823 0.823 0.823Strip and remove to skip-Cladding only ft 0.074 0.074 0.074 0.090 0.094 0.094 0.117 0.117 0.117Strip and store-Insulation and Cladding ft 0.148 0.148 0.148 0.179 0.187 0.187 0.233 0.233 0.233Strip and store-Cladding ft 0.103 0.103 0.103 0.125 0.131 0.131 0.163 0.163 0.163Strip, store and refit-Insulation and Cladding ft 0.332 0.332 0.332 0.402 0.420 0.420 0.521 0.521 0.521Strip, store and refit-Cladding ft 0.232 0.232 0.232 0.281 0.294 0.294 0.365 0.365 0.365Strip, store and refit-Cladding;remove and renew Insulation ft 0.322 0.322 0.322 0.390 0.408 0.408 0.506 0.506 0.506Extra over Elbow or Bend Nr 0.740 0.740 0.740 0.896 0.936 0.936 1.162 1.162 1.162Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.370 0.370 0.370 0.448 0.468 0.468 0.581 0.581 0.581Extra over Flange Joint-mineral wool Nr 1.056 1.056 1.056 1.281 1.337 1.337 1.660 1.660 1.660Extra over Valve or Strainer-mineral wool Nr 1.585 1.585 1.585 1.921 2.006 2.006 2.490 2.490 2.490Strip, remove and renew Cladding only ft 0.210 0.210 0.210 0.254 0.266 0.266 0.330 0.330 0.330Extra over Elbow or Bend Nr 0.610Extra over Tee, Reducer, Full Cap End or End Closure Plate Nr 0.305
Unit20" pipe sizeInsulation Thickness
1" 1 1/2" 2" 2 1/2" 5 1/2" 6"3" 4" 4 1/2" 5"
209
L.2.5 Glass Rope Spirally Wound To Pipework
UnitNorm Norm Norm Norm Norm Norm Norm
New Complete Specification m 0.285 0.302 0.308 0.331 0.384 0.486 0.600
Extra over Flange Joint Nr 0.117 0.123 0.126 0.136 0.158 0.199 0.246
Extra over Valve or Strainer Nr 0.205 0.216 0.222 0.238 0.277 0.349 0.433
Strip and remove to skip-Insulation and Coverings m 0.157 0.164 0.171 0.184 0.213 0.266 0.331
Extra over Flange Joint Nr 0.064 0.068 0.069 0.075 0.087 0.109 0.135
Extra over Valve or Strainer Nr 0.113 0.119 0.122 0.131 0.152 0.192 0.238
Strip, remove and renew Complete Specification m 0.443 0.466 0.479 0.512 0.597 0.751 0.932
Extra over Flange Joint Nr 0.181 0.191 0.196 0.210 0.245 0.308 0.382
Extra over Valve or Strainer Nr 0.318 0.335 0.344 0.370 0.430 0.541 0.670
25mm Insulation Thickness 50mm 75mm 100mmPipe Size
12mm 18mm 25mm 37mm
UnitNorm Norm Norm Norm Norm Norm Norm
New Complete Specification ft 0.087 0.092 0.094 0.101 0.117 0.148 0.183
Extra over Flange Joint Nr 0.117 0.123 0.126 0.136 0.158 0.199 0.246
Extra over Valve or Strainer Nr 0.205 0.216 0.222 0.238 0.277 0.349 0.433
Strip and remove to skip-Insulation and Coverings ft 0.048 0.050 0.052 0.056 0.065 0.081 0.101
Extra over Flange Joint Nr 0.064 0.068 0.069 0.075 0.087 0.109 0.135
Extra over Valve or Strainer Nr 0.113 0.119 0.122 0.131 0.152 0.192 0.238
Strip, remove and renew Complete Specification ft 0.135 0.142 0.146 0.156 0.182 0.229 0.284
Extra over Flange Joint Nr 0.181 0.191 0.196 0.210 0.245 0.308 0.382
Extra over Valve or Strainer Nr 0.318 0.335 0.344 0.370 0.430 0.541 0.670
1" Insulation Thickness 2" 3" 4"Pipe Size
1/2" 3/4" 1" 1 1/2"
210
L.2.6 Vessels, Tanks, Columns & Equipment Insulated with Mineral Wool Rigid Slabs or Flexible Mattress
Up to 0.7mm Flat Aluzinc or Aluminium Unit
Norm Norm NormNew Complete Specification m2 0.861 1.023 1.195
Stiffener Flange m2 1.249 1.485 1.733
Removable Cover m2 1.453 1.722 2.013
Dished End m2 1.442 1.711 1.991
Tank Roof m2 1.033 1.227 1.432
Extra over for 1 extra layer than specified m2 1.033 1.227 1.432
Stiffener Flange m2 1.507 1.787 2.077
Removable Cover m2 1.744 2.067 2.411
Dished End m2 1.733 2.056 2.400
Tank Roof m2 1.249 1.475 1.722
Extra over for 2 extra layers than specified m2 1.206 1.432 1.668
Stiffener Flange m2 1.755 2.077 2.422
Removable Cover m2 2.034 2.411 2.809
Dished End m2 2.024 2.400 2.799
Tank Roof m2 1.453 1.722 2.013
Strip and remove to skip-Insulation and Cladding m2 0.388 0.463 0.538
Stiffener Flange m2 0.560 0.667 0.775
Removable Cover m2 0.657 0.775 0.904
Dished End m2 0.646 0.775 0.893
Tank Roof m2 0.463 0.549 0.646
Strip and remove to skip-Cladding only m2 0.269 0.323 0.377
Stiffener Flange m2 0.398 0.474 0.549
Removable Cover m2 0.452 0.538 0.635
Dished End m2 0.452 0.538 0.624
Tank Roof m2 0.323 0.388 0.452
Strip and store-Insulation and Cladding m2 0.560 0.667 0.775
Stiffener Flange m2 0.818 0.969 1.130
Removable Cover m2 0.947 1.119 1.302
Dished End m2 0.936 1.109 1.302
Tank Roof m2 0.678 0.797 0.936
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS OR FLEXIBLE MATTRESS
Insulation ThicknessOver 100mm n.e. 200mm
Over 200mm n.e. 250mm
n.e. 100mm
211
Up to 0.7mm Flat Aluzinc or Aluminium Unit
Norm Norm Norm
Strip and store-Cladding m2 0.398 0.463 0.549
Stiffener Flange m2 0.570 0.678 0.786
Removable Cover m2 0.657 0.786 0.915
Dished End m2 0.657 0.775 0.904
Tank Roof m2 0.474 0.560 0.657
Strip, store and refit-Insulation and Cladding m2 1.378 1.636 1.916
Stiffener Flange m2 2.002 2.379 2.777
Removable Cover m2 2.325 2.756 3.208
Dished End m2 2.303 2.745 3.197
Tank Roof m2 1.658 1.970 2.293
Strip, store and refit-Cladding m2 0.969 1.152 1.335
Stiffener Flange m2 1.399 1.668 1.938
Removable Cover m2 1.625 1.927 2.250
Dished End m2 1.615 1.916 2.239
Tank Roof m2 1.163 1.378 1.604
Strip, store and refit Cladding;remove and renew Insulation m2 1.345 1.593 1.862
Stiffener Flange m2 1.948 2.314 2.691
Removable Cover m2 2.260 2.680 3.122
Dished End m2 2.239 2.659 3.100
Tank Roof m2 1.615 1.916 2.228
Strip, remove and renew Cladding only m2 0.872 1.044 1.216
Stiffener Flange m2 1.270 1.507 1.755
Removable Cover m2 1.475 1.744 2.034
Dished End m2 1.464 1.744 2.024
Tank Roof m2 1.055 1.249 1.453
Strip, remove and renew Complete Specification m2 1.249 1.485 1.733
Stiffener Flange m2 1.819 2.153 2.508
Removable Cover m2 2.110 2.497 2.906
Dished End m2 2.088 2.486 2.895
Tank Roof m2 1.507 1.787 2.077
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS OR FLEXIBLE MATTRESS
Over 100mm n.e. 200mm
Over 200mm n.e. 250mm
Insulation Thickness
n.e. 100mm
212
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft2 0.080 0.080 0.080 0.080 0.080 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.111
Stiffener Flange ft2 0.116 0.116 0.116 0.116 0.116 0.138 0.138 0.138 0.138 0.138 0.138 0.138 0.161
Dished End ft2 0.134 0.134 0.134 0.134 0.134 0.159 0.159 0.159 0.159 0.159 0.159 0.159 0.185
Tank Roof ft2 0.096 0.096 0.096 0.096 0.096 0.114 0.114 0.114 0.114 0.114 0.114 0.114 0.133
Extra over for 1 extra layer than specified ft2 0.096 0.096 0.096 0.096 0.096 0.114 0.114 0.114 0.114 0.114 0.114 0.114 0.133
Stiffener Flange ft2 0.140 0.140 0.140 0.140 0.140 0.166 0.166 0.166 0.166 0.166 0.166 0.166 0.193
Dished End ft2 0.161 0.161 0.161 0.161 0.161 0.191 0.191 0.191 0.191 0.191 0.191 0.191 0.223
Tank Roof ft2 0.116 0.116 0.116 0.116 0.116 0.137 0.137 0.137 0.137 0.137 0.137 0.137 0.160
Extra over for 2 extra layers than specified ft2 0.112 0.112 0.112 0.112 0.112 0.133 0.133 0.133 0.133 0.133 0.133 0.133 0.155
Stiffener Flange ft2 0.163 0.163 0.163 0.163 0.163 0.193 0.193 0.193 0.193 0.193 0.193 0.193 0.225
Dished End ft2 0.188 0.188 0.188 0.188 0.188 0.223 0.223 0.223 0.223 0.223 0.223 0.223 0.260
Tank Roof ft2 0.135 0.135 0.135 0.135 0.135 0.160 0.160 0.160 0.160 0.160 0.160 0.160 0.187
Strip and remove to skip-Insulation and Cladding ft2 0.036 0.036 0.036 0.036 0.036 0.043 0.043 0.043 0.043 0.043 0.043 0.043 0.050
Stiffener Flange ft2 0.052 0.052 0.052 0.052 0.052 0.062 0.062 0.062 0.062 0.062 0.062 0.062 0.072
Dished End ft2 0.060 0.060 0.060 0.060 0.060 0.072 0.072 0.072 0.072 0.072 0.072 0.072 0.083
Tank Roof ft2 0.043 0.043 0.043 0.043 0.043 0.051 0.051 0.051 0.051 0.051 0.051 0.051 0.060
Strip and remove to skip-Cladding only ft2 0.025 0.025 0.025 0.025 0.025 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.035
Stiffener Flange ft2 0.037 0.037 0.037 0.037 0.037 0.044 0.044 0.044 0.044 0.044 0.044 0.044 0.051
Dished End ft2 0.042 0.042 0.042 0.042 0.042 0.050 0.050 0.050 0.050 0.050 0.050 0.050 0.058
Tank Roof ft2 0.030 0.030 0.030 0.030 0.030 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.042
Strip and store-Insulation and Cladding ft2 0.052 0.052 0.052 0.052 0.052 0.062 0.062 0.062 0.062 0.062 0.062 0.062 0.072
Stiffener Flange ft2 0.076 0.076 0.076 0.076 0.076 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.105
Dished End ft2 0.087 0.087 0.087 0.087 0.087 0.103 0.103 0.103 0.103 0.103 0.103 0.103 0.121
Tank Roof ft2 0.063 0.063 0.063 0.063 0.063 0.074 0.074 0.074 0.074 0.074 0.074 0.074 0.087
Up to 24 mil Flat Aluzinc or Aluminium Unit 10"4 1/2" 5" 5 1/2" 6" 8"1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"Insulation Thickness
213
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormStrip and store-Cladding ft2 0.037 0.037 0.037 0.037 0.037 0.043 0.043 0.043 0.043 0.043 0.043 0.043 0.051
Stiffener Flange ft2 0.053 0.053 0.053 0.053 0.053 0.063 0.063 0.063 0.063 0.063 0.063 0.063 0.073
Dished End ft2 0.061 0.061 0.061 0.061 0.061 0.072 0.072 0.072 0.072 0.072 0.072 0.072 0.084
Tank Roof ft2 0.044 0.044 0.044 0.044 0.044 0.052 0.052 0.052 0.052 0.052 0.052 0.052 0.061
Strip, store and refit-Insulation and Cladding ft2 0.128 0.128 0.128 0.128 0.128 0.152 0.152 0.152 0.152 0.152 0.152 0.152 0.178
Stiffener Flange ft2 0.186 0.186 0.186 0.186 0.186 0.221 0.221 0.221 0.221 0.221 0.221 0.221 0.258
Dished End ft2 0.214 0.214 0.214 0.214 0.214 0.255 0.255 0.255 0.255 0.255 0.255 0.255 0.297
Tank Roof ft2 0.154 0.154 0.154 0.154 0.154 0.183 0.183 0.183 0.183 0.183 0.183 0.183 0.213
Strip, store and refit-Cladding ft2 0.090 0.090 0.090 0.090 0.090 0.107 0.107 0.107 0.107 0.107 0.107 0.107 0.124
Stiffener Flange ft2 0.130 0.130 0.130 0.130 0.130 0.155 0.155 0.155 0.155 0.155 0.155 0.155 0.180
Dished End ft2 0.150 0.150 0.150 0.150 0.150 0.178 0.178 0.178 0.178 0.178 0.178 0.178 0.208
Tank Roof ft2 0.108 0.108 0.108 0.108 0.108 0.128 0.128 0.128 0.128 0.128 0.128 0.128 0.149
Strip, store and refit Cladding;remove and renew Insulation ft2 0.125 0.125 0.125 0.125 0.125 0.148 0.148 0.148 0.148 0.148 0.148 0.148 0.173
Stiffener Flange ft2 0.181 0.181 0.181 0.181 0.181 0.215 0.215 0.215 0.215 0.215 0.215 0.215 0.250
Dished End ft2 0.208 0.208 0.208 0.208 0.208 0.247 0.247 0.247 0.247 0.247 0.247 0.247 0.288
Tank Roof ft2 0.150 0.150 0.150 0.150 0.150 0.178 0.178 0.178 0.178 0.178 0.178 0.178 0.207
Strip, remove and renew Cladding only ft2 0.081 0.081 0.081 0.081 0.081 0.097 0.097 0.097 0.097 0.097 0.097 0.097 0.113
Stiffener Flange ft2 0.118 0.118 0.118 0.118 0.118 0.140 0.140 0.140 0.140 0.140 0.140 0.140 0.163
Dished End ft2 0.136 0.136 0.136 0.136 0.136 0.162 0.162 0.162 0.162 0.162 0.162 0.162 0.188
Tank Roof ft2 0.098 0.098 0.098 0.098 0.098 0.116 0.116 0.116 0.116 0.116 0.116 0.116 0.135
Strip, remove and renew Complete Specification ft2 0.116 0.116 0.116 0.116 0.116 0.138 0.138 0.138 0.138 0.138 0.138 0.138 0.161
Stiffener Flange ft2 0.169 0.169 0.169 0.169 0.169 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.233
Dished End ft2 0.194 0.194 0.194 0.194 0.194 0.231 0.231 0.231 0.231 0.231 0.231 0.231 0.269
Tank Roof ft2 0.140 0.140 0.140 0.140 0.140 0.166 0.166 0.166 0.166 0.166 0.166 0.166 0.193
5 1/2" 6" 8" 10"2 1/2" 3" 3 1/2" 4" 4 1/2" 5"Up to 24 mil Flat Aluzinc or Aluminium UnitInsulation Thickness
1" 1 1/2" 2"
214
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft2 0.080 0.080 0.080 0.080 0.080 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.111
Stiffener Flange ft2 0.116 0.116 0.116 0.116 0.116 0.138 0.138 0.138 0.138 0.138 0.138 0.138 0.161
Removable Cover ft2 0.135 0.135 0.135 0.135 0.135 0.160 0.160 0.160 0.160 0.160 0.160 0.160 0.187
Dished End ft2 0.134 0.134 0.134 0.134 0.134 0.159 0.159 0.159 0.159 0.159 0.159 0.159 0.185
Tank Roof ft2 0.096 0.096 0.096 0.096 0.096 0.114 0.114 0.114 0.114 0.114 0.114 0.114 0.133
Extra over for 1 extra layer than specified ft2 0.096 0.096 0.096 0.096 0.096 0.114 0.114 0.114 0.114 0.114 0.114 0.114 0.133
Stiffener Flange ft2 0.140 0.140 0.140 0.140 0.140 0.166 0.166 0.166 0.166 0.166 0.166 0.166 0.193
Removable Cover ft2 0.162 0.162 0.162 0.162 0.162 0.192 0.192 0.192 0.192 0.192 0.192 0.192 0.224
Dished End ft2 0.161 0.161 0.161 0.161 0.161 0.191 0.191 0.191 0.191 0.191 0.191 0.191 0.223
Tank Roof ft2 0.116 0.116 0.116 0.116 0.116 0.137 0.137 0.137 0.137 0.137 0.137 0.137 0.160
Extra over for 2 extra layers than specified ft2 0.112 0.112 0.112 0.112 0.112 0.133 0.133 0.133 0.133 0.133 0.133 0.133 0.155
Stiffener Flange ft2 0.163 0.163 0.163 0.163 0.163 0.193 0.193 0.193 0.193 0.193 0.193 0.193 0.225
Removable Cover ft2 0.189 0.189 0.189 0.189 0.189 0.224 0.224 0.224 0.224 0.224 0.224 0.224 0.261
Dished End ft2 0.188 0.188 0.188 0.188 0.188 0.223 0.223 0.223 0.223 0.223 0.223 0.223 0.260
Tank Roof ft2 0.135 0.135 0.135 0.135 0.135 0.160 0.160 0.160 0.160 0.160 0.160 0.160 0.187
Strip and remove to skip-Insulation and Cladding ft2 0.036 0.036 0.036 0.036 0.036 0.043 0.043 0.043 0.043 0.043 0.043 0.043 0.050
Stiffener Flange ft2 0.052 0.052 0.052 0.052 0.052 0.062 0.062 0.062 0.062 0.062 0.062 0.062 0.072
Removable Cover ft2 0.061 0.061 0.061 0.061 0.061 0.072 0.072 0.072 0.072 0.072 0.072 0.072 0.084
Dished End ft2 0.060 0.060 0.060 0.060 0.060 0.072 0.072 0.072 0.072 0.072 0.072 0.072 0.083
Tank Roof ft2 0.043 0.043 0.043 0.043 0.043 0.051 0.051 0.051 0.051 0.051 0.051 0.051 0.060
Strip and remove to skip-Cladding only ft2 0.025 0.025 0.025 0.025 0.025 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.035
Stiffener Flange ft2 0.037 0.037 0.037 0.037 0.037 0.044 0.044 0.044 0.044 0.044 0.044 0.044 0.051
Removable Cover ft2 0.042 0.042 0.042 0.042 0.042 0.050 0.050 0.050 0.050 0.050 0.050 0.050 0.059
Dished End ft2 0.042 0.042 0.042 0.042 0.042 0.050 0.050 0.050 0.050 0.050 0.050 0.050 0.058
Tank Roof ft2 0.030 0.030 0.030 0.030 0.030 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.042
Strip and store-Insulation and Cladding ft2 0.052 0.052 0.052 0.052 0.052 0.062 0.062 0.062 0.062 0.062 0.062 0.062 0.072
Stiffener Flange ft2 0.076 0.076 0.076 0.076 0.076 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.105
Removable Cover ft2 0.088 0.088 0.088 0.088 0.088 0.104 0.104 0.104 0.104 0.104 0.104 0.104 0.121
Dished End ft2 0.087 0.087 0.087 0.087 0.087 0.103 0.103 0.103 0.103 0.103 0.103 0.103 0.121
Tank Roof ft2 0.063 0.063 0.063 0.063 0.063 0.074 0.074 0.074 0.074 0.074 0.074 0.074 0.087
32 mil Flat Aluzinc or Aluminium Unit 4 1/2" 5" 5 1/2" 6" 8" 10"Insulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
215
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormStrip and store-Cladding ft2 0.037 0.037 0.037 0.037 0.037 0.043 0.043 0.043 0.043 0.043 0.043 0.043 0.051
Stiffener Flange ft2 0.053 0.053 0.053 0.053 0.053 0.063 0.063 0.063 0.063 0.063 0.063 0.063 0.073
Removable Cover ft2 0.061 0.061 0.061 0.061 0.061 0.073 0.073 0.073 0.073 0.073 0.073 0.073 0.085
Dished End ft2 0.061 0.061 0.061 0.061 0.061 0.072 0.072 0.072 0.072 0.072 0.072 0.072 0.084
Tank Roof ft2 0.044 0.044 0.044 0.044 0.044 0.052 0.052 0.052 0.052 0.052 0.052 0.052 0.061
Strip, store and refit-Insulation and Cladding ft2 0.128 0.128 0.128 0.128 0.128 0.152 0.152 0.152 0.152 0.152 0.152 0.152 0.178
Stiffener Flange ft2 0.186 0.186 0.186 0.186 0.186 0.221 0.221 0.221 0.221 0.221 0.221 0.221 0.258
Removable Cover ft2 0.216 0.216 0.216 0.216 0.216 0.256 0.256 0.256 0.256 0.256 0.256 0.256 0.298
Dished End ft2 0.214 0.214 0.214 0.214 0.214 0.255 0.255 0.255 0.255 0.255 0.255 0.255 0.297
Tank Roof ft2 0.154 0.154 0.154 0.154 0.154 0.183 0.183 0.183 0.183 0.183 0.183 0.183 0.213
Strip, store and refit-Cladding ft2 0.090 0.090 0.090 0.090 0.090 0.107 0.107 0.107 0.107 0.107 0.107 0.107 0.124
Stiffener Flange ft2 0.130 0.130 0.130 0.130 0.130 0.155 0.155 0.155 0.155 0.155 0.155 0.155 0.180
Removable Cover ft2 0.151 0.151 0.151 0.151 0.151 0.179 0.179 0.179 0.179 0.179 0.179 0.179 0.209
Dished End ft2 0.150 0.150 0.150 0.150 0.150 0.178 0.178 0.178 0.178 0.178 0.178 0.178 0.208
Tank Roof ft2 0.108 0.108 0.108 0.108 0.108 0.128 0.128 0.128 0.128 0.128 0.128 0.128 0.149
Strip, store and refit Cladding;remove and renew Insulation ft2 0.125 0.125 0.125 0.125 0.125 0.148 0.148 0.148 0.148 0.148 0.148 0.148 0.173
Stiffener Flange ft2 0.181 0.181 0.181 0.181 0.181 0.215 0.215 0.215 0.215 0.215 0.215 0.215 0.250
Removable Cover ft2 0.210 0.210 0.210 0.210 0.210 0.249 0.249 0.249 0.249 0.249 0.249 0.249 0.290
Dished End ft2 0.208 0.208 0.208 0.208 0.208 0.247 0.247 0.247 0.247 0.247 0.247 0.247 0.288
Tank Roof ft2 0.150 0.150 0.150 0.150 0.150 0.178 0.178 0.178 0.178 0.178 0.178 0.178 0.207
Strip, remove and renew Cladding only ft2 0.081 0.081 0.081 0.081 0.081 0.097 0.097 0.097 0.097 0.097 0.097 0.097 0.113
Stiffener Flange ft2 0.118 0.118 0.118 0.118 0.118 0.140 0.140 0.140 0.140 0.140 0.140 0.140 0.163
Removable Cover ft2 0.137 0.137 0.137 0.137 0.137 0.162 0.162 0.162 0.162 0.162 0.162 0.162 0.189
Dished End ft2 0.136 0.136 0.136 0.136 0.136 0.162 0.162 0.162 0.162 0.162 0.162 0.162 0.188
Tank Roof ft2 0.098 0.098 0.098 0.098 0.098 0.116 0.116 0.116 0.116 0.116 0.116 0.116 0.135
Strip, remove and renew Complete Specification ft2 0.116 0.116 0.116 0.116 0.116 0.138 0.138 0.138 0.138 0.138 0.138 0.138 0.161
Stiffener Flange ft2 0.169 0.169 0.169 0.169 0.169 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.233
Removable Cover ft2 0.196 0.196 0.196 0.196 0.196 0.232 0.232 0.232 0.232 0.232 0.232 0.232 0.270
Dished End ft2 0.194 0.194 0.194 0.194 0.194 0.231 0.231 0.231 0.231 0.231 0.231 0.231 0.269
Tank Roof ft2 0.140 0.140 0.140 0.140 0.140 0.166 0.166 0.166 0.166 0.166 0.166 0.166 0.193
6" 8" 10"3" 3 1/2" 4" 4 1/2" 5" 5 1/2"32 mil Flat Aluzinc or Aluminium UnitInsulation Thickness
1" 1 1/2" 2" 2 1/2"
216
Up to 0.7mm Corrugated Aluzinc Unit
Norm Norm NormNew Complete Specification m2 0.829 0.829 0.958
Extra over for 1 extra layer than specified m2 0.990 0.990 1.152
Extra over for 2 extra layers than specified m2 1.152 1.152 1.345
Strip and remove to skip-Insulation and Cladding m2 0.366 0.366 0.431
Strip and remove to skip-Cladding only m2 0.258 0.258 0.301
Strip and store-Insulation and Cladding m2 0.538 0.538 0.624
Strip and store-Cladding m2 0.377 0.377 0.441
Strip, store and refit-Insulation and Cladding m2 1.313 1.313 1.539
Strip, store and refit-Cladding m2 0.926 0.926 1.076
Strip, store and refit Cladding;remove and renew Insulation m2 1.281 1.281 1.496
Strip, remove and renew Cladding only m2 0.840 0.840 0.980
Strip, remove and renew Complete Specification m2 1.195 1.195 1.389
Over 100mm n.e. 200mm
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS OR FLEXIBLE MATTRESS
n.e. 100mm
Insulation ThicknessOver 200mm n.e. 250mm
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft2 0.064 0.064 0.064 0.064 0.064 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.089
Extra over for 1 extra layer than specified ft2 0.077 0.077 0.077 0.077 0.077 0.092 0.092 0.092 0.092 0.092 0.092 0.092 0.107
Extra over for 2 extra layers than specified ft2 0.089 0.089 0.089 0.089 0.089 0.107 0.107 0.107 0.107 0.107 0.107 0.107 0.125
Strip and remove to skip-Insulation and Cladding ft2 0.029 0.029 0.029 0.029 0.029 0.034 0.034 0.034 0.034 0.034 0.034 0.034 0.040
Strip and remove to skip-Cladding only ft2 0.020 0.020 0.020 0.020 0.020 0.024 0.024 0.024 0.024 0.024 0.024 0.024 0.028
Strip and store-Insulation and Cladding ft2 0.041 0.041 0.041 0.041 0.041 0.050 0.050 0.050 0.050 0.050 0.050 0.050 0.058
Strip and store-Cladding ft2 0.029 0.029 0.029 0.029 0.029 0.035 0.035 0.035 0.035 0.035 0.035 0.035 0.041
Strip, store and refit-Insulation and Cladding ft2 0.102 0.102 0.102 0.102 0.102 0.122 0.122 0.122 0.122 0.122 0.122 0.122 0.143
Strip, store and refit-Cladding ft2 0.071 0.071 0.071 0.071 0.071 0.086 0.086 0.086 0.086 0.086 0.086 0.086 0.100
Strip, store and refit Cladding;remove and renew Insulation ft2 0.099 0.099 0.099 0.099 0.099 0.119 0.119 0.119 0.119 0.119 0.119 0.119 0.139
Strip, remove and renew Cladding only ft2 0.065 0.065 0.065 0.065 0.065 0.078 0.078 0.078 0.078 0.078 0.078 0.078 0.091
Strip, remove and renew Complete Specification ft2 0.092 0.092 0.092 0.092 0.092 0.111 0.111 0.111 0.111 0.111 0.111 0.111 0.129
UnitUp to 24 mil Corrugated AluzincInsulation Thickness
10"3" 3 1/2" 4 1/2" 5" 8"4" 5 1/2" 6"1" 1 1/2" 2" 2 1/2"
217
Armourset Cement Unit
Norm Norm NormNew Complete Specification m2 0.947 1.130 1.313
Stiffener Flange m2 1.044 1.249 1.453
Dished End m2 1.130 1.356 1.582
Tank Roof m2 1.130 1.356 1.582
Extra over for 1 extra layer than specified m2 1.130 1.356 1.582
Stiffener Flange m2 1.249 1.496 1.733
Dished End m2 1.356 1.625 1.894
Tank Roof m2 1.496 1.625 1.894
Extra over for 2 extra layers than specified m2 1.324 1.582 1.841
Stiffener Flange m2 1.453 1.744 2.024
Dished End m2 1.582 1.905 2.207
Tank Roof m2 1.744 1.905 2.207
Strip and remove to skip-Insulation and Cladding m2 0.420 0.506 0.592
Stiffener Flange m2 0.463 0.560 0.657
Dished End m2 0.506 0.614 0.710
Tank Roof m2 0.506 0.614 0.710
Strip, remove and renew Complete Specification m2 1.367 1.636 1.905
Stiffener Flange m2 1.507 1.808 2.099
Dished End m2 1.647 1.970 2.293
Tank Roof m2 1.647 1.970 2.293
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS OR FLEXIBLE MATTRESS
Over 100mm n.e. 200mm
Over 200mm n.e. 250mm
Insulation Thickness
n.e. 100mm
218
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft2 0.088 0.088 0.088 0.088 0.088 0.088 0.105 0.105 0.105 0.105 0.105 0.105 0.122
Stiffener Flange ft2 0.097 0.097 0.097 0.097 0.097 0.097 0.116 0.116 0.116 0.116 0.116 0.116 0.135
Dished End ft2 0.105 0.105 0.105 0.105 0.105 0.105 0.126 0.126 0.126 0.126 0.126 0.126 0.147
Tank Roof ft2 0.105 0.105 0.105 0.105 0.105 0.105 0.126 0.126 0.126 0.126 0.126 0.126 0.147
Extra over for 1 extra layer than specified ft2 0.105 0.105 0.105 0.105 0.105 0.105 0.126 0.126 0.126 0.126 0.126 0.126 0.147
Stiffener Flange ft2 0.116 0.116 0.116 0.116 0.116 0.116 0.139 0.139 0.139 0.139 0.139 0.139 0.161
Dished End ft2 0.126 0.126 0.126 0.126 0.126 0.126 0.151 0.151 0.151 0.151 0.151 0.151 0.176
Tank Roof ft2 0.139 0.139 0.139 0.139 0.139 0.139 0.166 0.151 0.151 0.151 0.151 0.151 0.176
Extra over for 2 extra layers than specified ft2 0.123 0.123 0.123 0.123 0.123 0.123 0.147 0.147 0.147 0.147 0.147 0.147 0.171
Stiffener Flange ft2 0.135 0.135 0.135 0.135 0.135 0.135 0.162 0.162 0.162 0.162 0.162 0.162 0.188
Dished End ft2 0.147 0.147 0.147 0.147 0.147 0.147 0.177 0.177 0.177 0.177 0.177 0.177 0.205
Tank Roof ft2 0.162 0.162 0.162 0.162 0.162 0.162 0.194 0.177 0.177 0.177 0.177 0.177 0.205
Strip and remove to skip-Insulation and Cladding ft2 0.039 0.039 0.039 0.039 0.039 0.039 0.047 0.047 0.047 0.047 0.047 0.047 0.055
Stiffener Flange ft2 0.043 0.043 0.043 0.043 0.043 0.043 0.052 0.052 0.052 0.052 0.052 0.052 0.061
Dished End ft2 0.047 0.047 0.047 0.047 0.047 0.047 0.057 0.057 0.057 0.057 0.057 0.057 0.066
Tank Roof ft2 0.047 0.047 0.047 0.047 0.047 0.047 0.057 0.057 0.057 0.057 0.057 0.057 0.066
Strip, remove and renew Complete Specification ft2 0.127 0.127 0.127 0.127 0.127 0.127 0.152 0.152 0.152 0.152 0.152 0.152 0.177
Stiffener Flange ft2 0.140 0.140 0.140 0.140 0.140 0.140 0.168 0.168 0.168 0.168 0.168 0.168 0.195
Dished End ft2 0.153 0.153 0.153 0.153 0.153 0.153 0.183 0.183 0.183 0.183 0.183 0.183 0.213
Tank Roof ft2 0.153 0.153 0.153 0.153 0.153 0.153 0.183 0.183 0.183 0.183 0.183 0.183 0.213
UnitArmourset CementInsulation Thickness
8" 10"4 1/2" 5" 5 1/2" 6"3 1/2" 4"1" 1 1/2" 2" 2 1/2" 3"
219
m2 0.183
Closing Collar (up to 0.9mm flat Alu. or SS) m 0.089
Unit
Utilising stud welding system on any thickness up to and including 10in in any number of layers
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS OR FLEXIBLE MATTRESS
NormGeneral
Utilising stud welding system on any thickness uptoand including250 mm in any number of layers ft2 0.0170.7 mm Flat Aluzinc or Aluminium Closing Collar ft 0.0270.9 mm Flat Aluzinc or Aluminium Closing Collar ft 0.0270.8 mm Flat Stainless Steel ft 0.027
General
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL RIGID SLABS
NormUnit
220
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL FLEXIBLE MATTRESS
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft2 0.080 0.080 0.080 0.080 0.080 0.080 0.080 0.095 0.095 0.095 0.095 0.095 0.111
Stiffener Flange ft2 0.116 0.116 0.116 0.116 0.116 0.116 0.116 0.138 0.138 0.138 0.138 0.138 0.161Dished End ft2 0.134 0.134 0.134 0.134 0.134 0.134 0.134 0.159 0.159 0.159 0.159 0.159 0.185
Extra over for 1 extra layer than specified ft2 0.096 0.096 0.096 0.096 0.096 0.096 0.096 0.114 0.114 0.114 0.114 0.114 0.133Stiffener Flange ft2 0.140 0.140 0.140 0.140 0.140 0.140 0.140 0.166 0.166 0.166 0.166 0.166 0.193Dished End ft2 0.161 0.161 0.161 0.161 0.161 0.161 0.161 0.191 0.191 0.191 0.191 0.191 0.223
Extra over for 2 extra layers than specified ft2 0.112 0.112 0.112 0.112 0.112 0.112 0.112 0.133 0.133 0.133 0.133 0.133 0.155Stiffener Flange ft2 0.163 0.163 0.163 0.163 0.163 0.163 0.163 0.193 0.193 0.193 0.193 0.193 0.225Dished End ft2 0.188 0.188 0.188 0.188 0.188 0.188 0.188 0.223 0.223 0.223 0.223 0.223 0.260
Strip and remove to skip-Insulation and Cladding ft2 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.043 0.043 0.043 0.043 0.043 0.050Stiffener Flange ft2 0.052 0.052 0.052 0.052 0.052 0.052 0.052 0.062 0.062 0.062 0.062 0.062 0.072Dished End ft2 0.060 0.060 0.060 0.060 0.060 0.060 0.060 0.072 0.072 0.072 0.072 0.072 0.083
Strip and remove to skip-Cladding only ft2 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.030 0.030 0.030 0.030 0.030 0.035Stiffener Flange ft2 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.044 0.044 0.044 0.044 0.044 0.051Dished End ft2 0.042 0.042 0.042 0.042 0.042 0.042 0.042 0.050 0.050 0.050 0.050 0.050 0.058
Strip and store-Insulation and Cladding ft2 0.052 0.052 0.052 0.052 0.052 0.052 0.052 0.062 0.062 0.062 0.062 0.062 0.072Stiffener Flange ft2 0.076 0.076 0.076 0.076 0.076 0.076 0.076 0.090 0.090 0.090 0.090 0.090 0.105Dished End ft2 0.087 0.087 0.087 0.087 0.087 0.087 0.087 0.103 0.103 0.103 0.103 0.103 0.121
Strip and store-Cladding ft2 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.043 0.043 0.043 0.043 0.043 0.051Stiffener Flange ft2 0.053 0.053 0.053 0.053 0.053 0.053 0.053 0.063 0.063 0.063 0.063 0.063 0.073Dished End ft2 0.061 0.061 0.061 0.061 0.061 0.061 0.061 0.072 0.072 0.072 0.072 0.072 0.084
Strip, store and refit-Insulation and Cladding ft2 0.128 0.128 0.128 0.128 0.128 0.128 0.128 0.152 0.152 0.152 0.152 0.152 0.178Stiffener Flange ft2 0.186 0.186 0.186 0.186 0.186 0.186 0.186 0.221 0.221 0.221 0.221 0.221 0.258Dished End ft2 0.214 0.214 0.214 0.214 0.214 0.214 0.214 0.255 0.255 0.255 0.255 0.255 0.297
Strip, store and refit-Cladding ft2 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.107 0.107 0.107 0.107 0.107 0.124Stiffener Flange ft2 0.130 0.130 0.130 0.130 0.130 0.130 0.130 0.155 0.155 0.155 0.155 0.155 0.180Dished End ft2 0.150 0.150 0.150 0.150 0.150 0.150 0.150 0.178 0.178 0.178 0.178 0.178 0.208
Strip, store and refit Cladding;remove and renew Insulation ft2 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.148 0.148 0.148 0.148 0.148 0.173Stiffener Flange ft2 0.181 0.181 0.181 0.181 0.181 0.181 0.181 0.215 0.215 0.215 0.215 0.215 0.250Dished End ft2 0.208 0.208 0.208 0.208 0.208 0.208 0.208 0.247 0.247 0.247 0.247 0.247 0.288
Strip, remove and renew Cladding only ft2 0.081 0.081 0.081 0.081 0.081 0.081 0.081 0.097 0.097 0.097 0.097 0.097 0.113Stiffener Flange ft2 0.118 0.118 0.118 0.118 0.118 0.118 0.118 0.140 0.140 0.140 0.140 0.140 0.163Dished End ft2 0.136 0.136 0.136 0.136 0.136 0.136 0.136 0.162 0.162 0.162 0.162 0.162 0.188
Strip, remove and renew Complete Specification ft2 0.116 0.116 0.116 0.116 0.116 0.116 0.116 0.138 0.138 0.138 0.138 0.138 0.161Stiffener Flange ft2 0.169 0.169 0.169 0.169 0.169 0.169 0.169 0.200 0.200 0.200 0.200 0.200 0.233Dished End ft2 0.194 0.194 0.194 0.194 0.194 0.194 0.194 0.231 0.231 0.231 0.231 0.231 0.269
4 1/2" 5" 5 1/2" 6" 8" 10"Up to 24 mil Flat Aluzinc or AluminiumInsulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"Unit
221
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL FLEXIBLE MATTRESS
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft2 0.080 0.080 0.080 0.080 0.080 0.080 0.080 0.095 0.095 0.095 0.095 0.095 0.111
Stiffener Flange ft2 0.116 0.116 0.116 0.116 0.116 0.116 0.116 0.138 0.138 0.138 0.138 0.138 0.161Removable Cover ft2 0.135 0.135 0.135 0.135 0.135 0.135 0.135 0.160 0.160 0.160 0.160 0.160 0.187Dished End ft2 0.134 0.134 0.134 0.134 0.134 0.134 0.134 0.159 0.159 0.159 0.159 0.159 0.185
Extra over for 1 extra layer than specified ft2 0.096 0.096 0.096 0.096 0.096 0.096 0.096 0.114 0.114 0.114 0.114 0.114 0.133Stiffener Flange ft2 0.140 0.140 0.140 0.140 0.140 0.140 0.140 0.166 0.166 0.166 0.166 0.166 0.193Removable Cover ft2 0.162 0.162 0.162 0.162 0.162 0.162 0.162 0.192 0.192 0.192 0.192 0.192 0.224Dished End ft2 0.161 0.161 0.161 0.161 0.161 0.161 0.161 0.191 0.191 0.191 0.191 0.191 0.223
Extra over for 2 extra layers than specified ft2 0.112 0.112 0.112 0.112 0.112 0.112 0.112 0.133 0.133 0.133 0.133 0.133 0.155Stiffener Flange ft2 0.163 0.163 0.163 0.163 0.163 0.163 0.163 0.193 0.193 0.193 0.193 0.193 0.225Removable Cover ft2 0.189 0.189 0.189 0.189 0.189 0.189 0.189 0.224 0.224 0.224 0.224 0.224 0.261Dished End ft2 0.188 0.188 0.188 0.188 0.188 0.188 0.188 0.223 0.223 0.223 0.223 0.223 0.260
Strip and remove to skip-Insulation and Cladding ft2 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.043 0.043 0.043 0.043 0.043 0.050Stiffener Flange ft2 0.052 0.052 0.052 0.052 0.052 0.052 0.052 0.062 0.062 0.062 0.062 0.062 0.072Removable Cover ft2 0.061 0.061 0.061 0.061 0.061 0.061 0.061 0.072 0.072 0.072 0.072 0.072 0.084Dished End ft2 0.060 0.060 0.060 0.060 0.060 0.060 0.060 0.072 0.072 0.072 0.072 0.072 0.083
Strip and remove to skip-Cladding only ft2 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.030 0.030 0.030 0.030 0.030 0.035Stiffener Flange ft2 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.044 0.044 0.044 0.044 0.044 0.051Removable Cover ft2 0.042 0.042 0.042 0.042 0.042 0.042 0.042 0.050 0.050 0.050 0.050 0.050 0.059Dished End ft2 0.042 0.042 0.042 0.042 0.042 0.042 0.042 0.050 0.050 0.050 0.050 0.050 0.058
Strip and store-Insulation and Cladding ft2 0.052 0.052 0.052 0.052 0.052 0.052 0.052 0.062 0.062 0.062 0.062 0.062 0.072Stiffener Flange ft2 0.076 0.076 0.076 0.076 0.076 0.076 0.076 0.090 0.090 0.090 0.090 0.090 0.105Removable Cover ft2 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.104 0.104 0.104 0.104 0.104 0.121Dished End ft2 0.087 0.087 0.087 0.087 0.087 0.087 0.087 0.103 0.103 0.103 0.103 0.103 0.121
Strip and store-Cladding ft2 0.037 0.037 0.037 0.037 0.037 0.037 0.037 0.043 0.043 0.043 0.043 0.043 0.051Stiffener Flange ft2 0.053 0.053 0.053 0.053 0.053 0.053 0.053 0.063 0.063 0.063 0.063 0.063 0.073Removable Cover ft2 0.061 0.061 0.061 0.061 0.061 0.061 0.061 0.073 0.073 0.073 0.073 0.073 0.085Dished End ft2 0.061 0.061 0.061 0.061 0.061 0.061 0.061 0.072 0.072 0.072 0.072 0.072 0.084
Strip, store and refit-Insulation and Cladding ft2 0.128 0.128 0.128 0.128 0.128 0.128 0.128 0.152 0.152 0.152 0.152 0.152 0.178Stiffener Flange ft2 0.186 0.186 0.186 0.186 0.186 0.186 0.186 0.221 0.221 0.221 0.221 0.221 0.258Removable Cover ft2 0.216 0.216 0.216 0.216 0.216 0.216 0.216 0.256 0.256 0.256 0.256 0.256 0.298Dished End ft2 0.214 0.214 0.214 0.214 0.214 0.214 0.214 0.255 0.255 0.255 0.255 0.255 0.297
Strip, store and refit-Cladding ft2 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.107 0.107 0.107 0.107 0.107 0.124Stiffener Flange ft2 0.130 0.130 0.130 0.130 0.130 0.130 0.130 0.155 0.155 0.155 0.155 0.155 0.180Removable Cover ft2 0.151 0.151 0.151 0.151 0.151 0.151 0.151 0.179 0.179 0.179 0.179 0.179 0.209Dished End ft2 0.150 0.150 0.150 0.150 0.150 0.150 0.150 0.178 0.178 0.178 0.178 0.178 0.208
Strip, store and refit Cladding;remove and renew Insulation ft2 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.148 0.148 0.148 0.148 0.148 0.173Stiffener Flange ft2 0.181 0.181 0.181 0.181 0.181 0.181 0.181 0.215 0.215 0.215 0.215 0.215 0.250Removable Cover ft2 0.210 0.210 0.210 0.210 0.210 0.210 0.210 0.249 0.249 0.249 0.249 0.249 0.290Dished End ft2 0.208 0.208 0.208 0.208 0.208 0.208 0.208 0.247 0.247 0.247 0.247 0.247 0.288
Strip, remove and renew Cladding only ft2 0.081 0.081 0.081 0.081 0.081 0.081 0.081 0.097 0.097 0.097 0.097 0.097 0.113Stiffener Flange ft2 0.118 0.118 0.118 0.118 0.118 0.118 0.118 0.140 0.140 0.140 0.140 0.140 0.163Removable Cover ft2 0.137 0.137 0.137 0.137 0.137 0.137 0.137 0.162 0.162 0.162 0.162 0.162 0.189Dished End ft2 0.136 0.136 0.136 0.136 0.136 0.136 0.136 0.162 0.162 0.162 0.162 0.162 0.188
Strip, remove and renew Complete Specification ft2 0.116 0.116 0.116 0.116 0.116 0.116 0.116 0.138 0.138 0.138 0.138 0.138 0.161Stiffener Flange ft2 0.169 0.169 0.169 0.169 0.169 0.169 0.169 0.200 0.200 0.200 0.200 0.200 0.233Removable Cover ft2 0.196 0.196 0.196 0.196 0.196 0.196 0.196 0.232 0.232 0.232 0.232 0.232 0.270Dished End ft2 0.194 0.194 0.194 0.194 0.194 0.194 0.194 0.231 0.231 0.231 0.231 0.231 0.269
32 mil Flat Aluzinc or Aluminium 4 1/2" 5" 5 1/2" 6" 8" 10"Insulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"Unit
222
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL FLEXIBLE MATTRESS
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft2 0.064 0.064 0.064 0.064 0.064 0.064 0.064 0.077 0.077 0.077 0.077 0.077 0.089Extra over for 1 extra layer than specified ft2 0.077 0.077 0.077 0.077 0.077 0.077 0.077 0.092 0.092 0.092 0.092 0.092 0.107Extra over for 2 extra layers than specified ft2 0.089 0.089 0.089 0.089 0.089 0.089 0.089 0.107 0.107 0.107 0.107 0.107 0.125Strip and remove to skip-Insulation and Cladding ft2 0.029 0.029 0.029 0.029 0.029 0.029 0.029 0.034 0.034 0.034 0.034 0.034 0.040Strip and remove to skip-Cladding only ft2 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.024 0.024 0.024 0.024 0.024 0.028Strip and store-Insulation and Cladding ft2 0.041 0.041 0.041 0.041 0.041 0.041 0.041 0.050 0.050 0.050 0.050 0.050 0.058Strip and store-Cladding ft2 0.029 0.029 0.029 0.029 0.029 0.029 0.029 0.035 0.035 0.035 0.035 0.035 0.041Strip, store and refit-Insulation and Cladding ft2 0.102 0.102 0.102 0.102 0.102 0.102 0.102 0.122 0.122 0.122 0.122 0.122 0.143Strip, store and refit-Cladding ft2 0.071 0.071 0.071 0.071 0.071 0.071 0.071 0.086 0.086 0.086 0.086 0.086 0.100Strip, store and refit Cladding;remove and renew Insulation ft2 0.099 0.099 0.099 0.099 0.099 0.099 0.099 0.119 0.119 0.119 0.119 0.119 0.139Strip, remove and renew Cladding only ft2 0.065 0.065 0.065 0.065 0.065 0.065 0.065 0.078 0.078 0.078 0.078 0.078 0.091Strip, remove and renew Complete Specification ft2 0.092 0.092 0.092 0.092 0.092 0.092 0.092 0.111 0.111 0.111 0.111 0.111 0.129
Up to 24 mil Corrugated AluzincInsulation Thickness
Unit 4 1/2" 5" 5 1/2" 6" 8" 10"1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H MINERAL WOOL FLEXIBLE MATTRESS
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft2 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.105 0.105 0.105 0.105 0.105 0.122
Stiffener Flange ft2 0.097 0.097 0.097 0.097 0.097 0.097 0.097 0.116 0.116 0.116 0.116 0.116 0.135Dished End ft2 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.126 0.126 0.126 0.126 0.126 0.147
Extra over for 1 extra layer than specified ft2 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.126 0.126 0.126 0.126 0.126 0.147Stiffener Flange ft2 0.116 0.116 0.116 0.116 0.116 0.116 0.116 0.139 0.139 0.139 0.139 0.139 0.161Dished End ft2 0.126 0.126 0.126 0.126 0.126 0.126 0.126 0.151 0.151 0.151 0.151 0.151 0.176
Extra over for 2 extra layers than specified ft2 0.123 0.123 0.123 0.123 0.123 0.123 0.123 0.147 0.147 0.147 0.147 0.147 0.171Stiffener Flange ft2 0.135 0.135 0.135 0.135 0.135 0.135 0.135 0.162 0.162 0.162 0.162 0.162 0.188Dished End ft2 0.147 0.147 0.147 0.147 0.147 0.147 0.147 0.177 0.177 0.177 0.177 0.177 0.205
Strip and remove to skip-Insulation and Cladding ft2 0.039 0.039 0.039 0.039 0.039 0.039 0.039 0.047 0.047 0.047 0.047 0.047 0.055Stiffener Flange ft2 0.043 0.043 0.043 0.043 0.043 0.043 0.043 0.052 0.052 0.052 0.052 0.052 0.061Dished End ft2 0.047 0.047 0.047 0.047 0.047 0.047 0.047 0.057 0.057 0.057 0.057 0.057 0.066
Strip, remove and renew Complete Specification ft2 0.127 0.127 0.127 0.127 0.127 0.127 0.127 0.152 0.152 0.152 0.152 0.152 0.177Stiffener Flange ft2 0.140 0.140 0.140 0.140 0.140 0.140 0.140 0.168 0.168 0.168 0.168 0.168 0.195Dished End ft2 0.153 0.153 0.153 0.153 0.153 0.153 0.153 0.183 0.183 0.183 0.183 0.183 0.213
Armourset Cement 4 1/2"Unit 5" 5 1/2" 6" 8" 10"Insulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4"
223
Utilising stud welding system on any thickness uptoand including250 mm in any number of layers ft2 0.0170.7 mm Flat Aluzinc or Aluminium Closing Collar ft 0.0270.9 mm Flat Aluzinc or Aluminium Closing Collar ft 0.0270.8 mm Flat Stainless Steel ft 0.027
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WITH
NormUnit
224
L.2.7 Vessels, Tanks, Columns & Equipment Insulated with Polyisocyanurate Slabs/Lags: VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H POLYISOCYANURATE SLABS/LAGS: VAPOUR SEAL (MASTIC AND NO. 10 GLASS CLOTH)
Up to 0.7mm Flat Aluzinc or Aluminium Unit
Norm Norm Norm NormNew Complete Specification m2 1.163 1.399 1.636 1.884
Stiffener Flange m2 1.561 1.873 2.196 2.519
Removable Cover m2 1.959 2.347 2.756 3.165
Dished End m2 1.938 2.336 2.734 3.143
Tank Roof m2 1.399 1.679 1.970 2.260
Extra over for 1 extra layer than specified m2 1.399 1.679 1.970 2.260
Stiffener Flange m2 1.873 2.250 2.637 3.025
Removable Cover m2 2.347 2.820 3.305 3.789
Dished End m2 2.336 2.799 3.283 3.767
Tank Roof m2 1.679 2.013 2.357 2.713
Extra over for 2 extra layers than specified m2 1.625 1.959 2.293 2.637
Stiffener Flange m2 2.185 2.626 3.078 3.531
Removable Cover m2 2.734 3.283 3.853 4.424
Dished End m2 2.723 3.272 3.832 4.402
Tank Roof m2 1.959 2.347 2.756 3.165
Strip and remove to skip-Insulation and Coverings m2 0.527 0.624 0.743 0.850
Stiffener Flange m2 0.700 0.840 0.990 1.130
Removable Cover m2 0.883 1.055 1.238 1.421
Dished End m2 0.872 1.055 1.227 1.410
Tank Roof m2 0.624 0.753 0.883 1.012
Strip, remove and renew Complete Specification m2 1.690 2.024 2.379 2.734
Stiffener Flange m2 2.260 2.713 3.186 3.660
Removable Cover m2 2.831 3.401 3.993 4.585
Dished End m2 2.820 3.380 3.972 4.553
Tank Roof m2 2.024 2.433 2.852 3.272
Insulation Thickness
n.e. 50mm Over 50mm n.e. 100mm
Over 100mm n.e. 175mm
Over 175mm n.e. 200mm
225
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H POLYISOCYANURATE SLABS/LAGS: VAPOUR SEAL (MASTIC AND NO. 10 GLASS CLOTH)
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft2 0.108 0.108 0.108 0.130 0.130 0.130 0.130 0.152 0.152 0.152 0.152 0.175
Stiffener Flange ft2 0.145 0.145 0.145 0.174 0.174 0.174 0.174 0.204 0.204 0.204 0.204 0.234
Removable Cover ft2 0.180 0.180 0.180 0.217 0.217 0.217 0.217 0.254 0.254 0.254 0.254 0.292
Dished End ft2 0.130 0.130 0.130 0.156 0.156 0.156 0.156 0.183 0.183 0.183 0.183 0.210
Extra over for 1 extra layer than specified ft2 0.130 0.130 0.130 0.156 0.156 0.156 0.156 0.183 0.183 0.183 0.183 0.210
Stiffener Flange ft2 0.174 0.174 0.174 0.209 0.209 0.209 0.209 0.245 0.245 0.245 0.245 0.281
Removable Cover ft2 0.217 0.217 0.217 0.260 0.260 0.260 0.260 0.305 0.305 0.305 0.305 0.350
Dished End ft2 0.156 0.156 0.156 0.187 0.187 0.187 0.187 0.219 0.219 0.219 0.219 0.252
Extra over for 2 extra layers than specified ft2 0.151 0.151 0.151 0.182 0.182 0.182 0.182 0.213 0.213 0.213 0.213 0.245
Stiffener Flange ft2 0.203 0.203 0.203 0.244 0.244 0.244 0.244 0.286 0.286 0.286 0.286 0.328
Removable Cover ft2 0.253 0.253 0.253 0.304 0.304 0.304 0.304 0.356 0.356 0.356 0.356 0.409
Dished End ft2 0.182 0.182 0.182 0.218 0.218 0.218 0.218 0.256 0.256 0.256 0.256 0.294
Strip and remove to skip-Insulation and Coverings ft2 0.049 0.049 0.049 0.058 0.058 0.078 0.058 0.069 0.069 0.069 0.069 0.079
Stiffener Flange ft2 0.065 0.065 0.065 0.078 0.078 0.105 0.078 0.092 0.092 0.092 0.092 0.105
Removable Cover ft2 0.081 0.081 0.081 0.098 0.098 0.131 0.098 0.114 0.114 0.114 0.114 0.131
Dished End ft2 0.058 0.058 0.058 0.070 0.070 0.094 0.070 0.082 0.082 0.082 0.082 0.094
Strip, remove and renew Complete Specification ft2 0.157 0.157 0.157 0.188 0.188 0.252 0.188 0.221 0.221 0.221 0.221 0.254
Stiffener Flange ft2 0.210 0.210 0.210 0.252 0.252 0.338 0.252 0.296 0.296 0.296 0.296 0.340
Removable Cover ft2 0.262 0.262 0.262 0.314 0.314 0.421 0.314 0.369 0.369 0.369 0.369 0.423
Dished End ft2 0.188 0.188 0.188 0.226 0.226 0.303 0.226 0.265 0.265 0.265 0.265 0.304
7" 8"Insulation Thickness
4" 5" 5 1/2" 6"3 1/2"UnitUp to 24 mil Flat Aluzinc or Aluminium 2 1/2" 3"1" 1 1/2" 2"
226
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H POLYISOCYANURATE SLABS/LAGS: VAPOUR SEAL (MASTIC AND NO. 10 GLASS CLOTH)
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft2 0.108 0.108 0.108 0.130 0.130 0.130 0.130 0.152 0.152 0.152 0.152 0.175
Stiffener Flange ft2 0.145 0.145 0.145 0.174 0.174 0.174 0.174 0.204 0.204 0.204 0.204 0.234
Removable Cover ft2 0.182 0.182 0.182 0.218 0.218 0.218 0.218 0.256 0.256 0.256 0.256 0.294
Dished End ft2 0.180 0.180 0.180 0.217 0.217 0.217 0.217 0.254 0.254 0.254 0.254 0.292
Tank Roof ft2 0.130 0.130 0.130 0.156 0.156 0.156 0.156 0.183 0.183 0.183 0.183 0.210
Extra over for 1 extra layer than specified ft2 0.130 0.130 0.130 0.156 0.156 0.156 0.156 0.183 0.183 0.183 0.183 0.210
Stiffener Flange ft2 0.174 0.174 0.174 0.209 0.209 0.209 0.209 0.245 0.245 0.245 0.245 0.281
Removable Cover ft2 0.218 0.218 0.218 0.262 0.262 0.262 0.262 0.307 0.307 0.307 0.307 0.352
Dished End ft2 0.217 0.217 0.217 0.260 0.260 0.260 0.260 0.305 0.305 0.305 0.305 0.350
Tank Roof ft2 0.156 0.156 0.156 0.187 0.187 0.187 0.187 0.219 0.219 0.219 0.219 0.252
Extra over for 2 extra layers than specified ft2 0.151 0.151 0.151 0.182 0.182 0.182 0.182 0.213 0.213 0.213 0.213 0.245
Stiffener Flange ft2 0.203 0.203 0.203 0.244 0.244 0.244 0.244 0.286 0.286 0.286 0.286 0.328
Removable Cover ft2 0.254 0.254 0.254 0.305 0.305 0.305 0.305 0.358 0.358 0.358 0.358 0.411
Dished End ft2 0.253 0.253 0.253 0.304 0.304 0.304 0.304 0.356 0.356 0.356 0.356 0.409
Tank Roof ft2 0.182 0.182 0.182 0.218 0.218 0.218 0.218 0.256 0.256 0.256 0.256 0.294
Strip and remove to skip-Insulation and Coverings ft2 0.049 0.049 0.049 0.058 0.058 0.058 0.058 0.069 0.069 0.069 0.069 0.079
Stiffener Flange ft2 0.065 0.065 0.065 0.078 0.078 0.078 0.078 0.092 0.092 0.092 0.092 0.105
Removable Cover ft2 0.082 0.082 0.082 0.098 0.098 0.098 0.098 0.115 0.115 0.115 0.115 0.132
Dished End ft2 0.081 0.081 0.081 0.098 0.098 0.098 0.098 0.114 0.114 0.114 0.114 0.131
Tank Roof ft2 0.058 0.058 0.058 0.070 0.070 0.070 0.070 0.082 0.082 0.082 0.082 0.094
Strip, remove and renew Complete Specification ft2 0.157 0.157 0.157 0.188 0.188 0.188 0.188 0.221 0.221 0.221 0.221 0.254
Stiffener Flange ft2 0.210 0.210 0.210 0.252 0.252 0.252 0.252 0.296 0.296 0.296 0.296 0.340
Removable Cover ft2 0.263 0.263 0.263 0.316 0.316 0.316 0.316 0.371 0.371 0.371 0.371 0.426
Dished End ft2 0.262 0.262 0.262 0.314 0.314 0.314 0.314 0.369 0.369 0.369 0.369 0.423
Tank Roof ft2 0.188 0.188 0.188 0.226 0.226 0.226 0.226 0.265 0.265 0.265 0.265 0.304
4" 5" 5 1/2" 6" 7" 8"Insulation Thickness
Unit32 mil Flat Aluzinc or Aluminium 1" 1 1/2" 2" 2 1/2" 3" 3 1/2"
227
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H POLYISOCYANURATE SLABS/LAGS: VAPOUR SEAL (MASTIC AND NO. 10 GLASS CLOTH)
Up to 0.7mm Corrugated Aluzinc or Aluminium Unit
Norm Norm Norm NormNew Complete Specification m2 1.023 1.776 1.507 1.755
Extra over for 1 extra layer than specified m2 1.227 2.131 1.808 2.099
Extra over for 2 extra layers than specified m2 1.432 2.486 2.110 2.454
Strip and remove to skip-Insulation and Coverings m2 0.463 0.797 0.678 0.786
Strip, remove and renew Complete Specification m2 1.485 2.573 2.185 2.540
Over 175mm n.e. 200mm
Insulation Thickness
n.e. 50mm Over 50mm n.e. 100mm
Over 100mm n.e. 175mm
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H POLYISOCYANURATE SLABS/LAGS: VAPOUR SEAL (MASTIC AND NO. 10 GLASS CLOTH)
Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm Norm NormNew Complete Specification ft2 0.095 0.095 0.095 0.118 0.148 0.118 0.165 0.140 0.140 0.140 0.140 0.163
Extra over for 1 extra layer than specified ft2 0.114 0.114 0.114 0.141 0.177 0.141 0.198 0.168 0.168 0.168 0.168 0.195
Extra over for 2 extra layers than specified ft2 0.133 0.133 0.133 0.165 0.207 0.165 0.231 0.196 0.196 0.196 0.196 0.228
Strip and remove to skip-Insulation and Coverings ft2 0.043 0.043 0.043 0.053 0.067 0.053 0.074 0.063 0.063 0.063 0.063 0.073
Strip, remove and renew Complete Specification ft2 0.138 0.138 0.138 0.171 0.214 0.171 0.239 0.203 0.203 0.203 0.203 0.236
4" 5" 5 1/2" 6"Up to 24 mil Corrugated Aluzinc or Aluminium Unit 7" 8"Insulation Thickness
1" 1 1/2" 2" 2 1/2" 3" 3 1/2"
m2 0.183Closing Collar (up to 0.9mm flat Alu. or SS) m 0.089
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WIT H POLYISOCYANURATE SLABS/LAGS, VAPOUR SEAL (MASTIC AN D NO. 10 GLASS CLOTH)
General Norm
Utilising stud welding system on any thickness up to and including
228
0.7 mm Flat Aluzinc or Aluminium Closing Collar ft 0.027
0.9 mm Flat Aluzinc or Aluminium Closing Collar ft 0.027
0.8 mm Flat Stainless Steel ft 0.027
Utilising stud welding system on any thickness up to and including 250 mm in any number of layers
General Unit Norm
VESSELS, TANKS, COLUMNS AND EQUIPMENT INSULATED WI TH POLYISOCYANURATE SLABS/LAGS: VAPOUR SEAL (MASTIC AN D NO. 10 GLASS CLOTH)
MaterialMaterial Factor
Base = Preformed Section Norms - Mineral Wool:Cellular Glass Preformed Section 0.400Calcium Silicate Preformed Section 0.050Perlite Preformed Section 0.050
Base = all Alu. Cladded specifications:Stainless Steel Cladded Calcium Silicate Preformed Section 0.145Stainless Steel Cladded Perlite Preformed Section 0.145Stainless Steel Cladded other specifications 0.093
229
M.1 Painting Norms
M.2.1 Grit blast of new & existing surfaces
Unit Norm Norm
girth over 300 m2 0.250 0.500isolated surfaces; girth up to 300 m 0.083 0.167
isolated areas; up to 0.50m2 Nr 0.250 0.500
girth over 300 m2 0.400 0.800isolated surfaces; girth up to 300 m 0.133 0.267
isolated areas; up to 0.50m2 Nr 0.400 0.800
up to 50 diameter m 0.120 0.24080 diameter m 0.140 0.280100 diameter m 0.160 0.320150 diameter m 0.220 0.440200 diameter m 0.280 0.560250 diameter m 0.340 0.680300 diameter m 0.400 0.800350 diameter m 0.450 0.900400 diameter m 0.500 1.000450 diameter m 0.550 1.100500 diameter m 0.600 1.200600 diameter m 0.700 1.400750 diameter m 0.850 1.700900 diameter m 1.000 2.0001100 diameter m 1.197 2.3941200 diameter m 1.276 2.5521350 diameter m 1.404 2.8071500 diameter m 1.525 3.049
80 diameter m 0.140 0.280100 diameter m 0.160 0.320150 diameter m 0.220 0.440200 diameter m 0.280 0.560250 diameter m 0.340 0.680300 diameter m 0.400 0.800350 diameter m 0.450 0.900400 diameter m 0.500 1.000450 diameter m 0.550 1.100500 diameter m 0.600 1.200600 diameter m 0.700 1.400750 diameter m 0.850 1.700900 diameter m 1.000 2.0001100 diameter m 1.197 2.3941200 diameter m 1.276 2.5521350 diameter m 1.404 2.8071500 diameter m 1.525 3.049
sides, internally m2 0.134 0.268sides, externally m2 0.134 0.268roofs, top m2 0.134 0.268roofs, underside m2 0.134 0.268floors, m2 0.134 0.268
general surfaces; externally m2 0.250 0.500general surfaces; internally m2 0.250 0.500
Extra over pipework for valves:
Tanks
Vessels
Grit blast to new and existing surfaces
SA 2 SA 2 1/2
Structural metalwork; members of roof trusses etc
Structural metalwork; general surfaces
Services; pipes including flanges
230
M.2.2 Grit blast to new & existing surfaces (includ ing remedials)
Unit Norm Norm
General Surfaces m2 0.525 1.050
up to 50 diameter m 0.180 0.36080 diameter m 0.210 0.420100 diameter m 0.240 0.480150 diameter m 0.330 0.660200 diameter m 0.420 0.840250 diameter m 0.510 1.020300 diameter m 0.600 1.200350 diameter m 0.675 1.350400 diameter m 0.750 1.500450 diameter m 0.825 1.650500 diameter m 0.900 1.800600 diameter m 1.050 2.100750 diameter m 1.275 2.550900 diameter m 1.500 3.0001100 diameter m 1.796 3.5911200 diameter m 1.914 3.8281350 diameter m 2.106 4.2111500 diameter m 2.288 4.574
80 diameter m 0.210 0.420100 diameter m 0.240 0.480150 diameter m 0.330 0.660200 diameter m 0.420 0.840250 diameter m 0.510 1.020300 diameter m 0.600 1.200350 diameter m 0.675 1.350400 diameter m 0.750 1.500450 diameter m 0.825 1.650500 diameter m 0.900 1.800600 diameter m 1.050 2.100750 diameter m 1.275 2.550900 diameter m 1.500 3.0001100 diameter m 1.796 3.5911200 diameter m 1.914 3.8281350 diameter m 2.106 4.2111500 diameter m 2.288 4.574
General Surfaces m2 0.201 0.401
general surfaces; externally m2 0.375 0.750
Tanks
Vessels
Grit blast to new and existing surfaces (including Remedials)
SA 2 SA 2 1/2
Structural metalwork; general surfaces
Services; pipes including flanges
Extra over pipework for valves:
231
M.2.3 Wet blast to existing surfaces
Unit Norm Norm
girth over 300 m2 0.333 0.667isolated surfaces; girth up to 300 m 0.111 0.222
isolated areas; up to 0.50m2 Nr 0.333 0.667
girth over 300 m2 0.533 1.067isolated surfaces; girth up to 300 m 0.178 0.356
isolated areas; up to 0.50m2 Nr 0.533 1.067
up to 50 diameter m 0.160 0.32080 diameter m 0.187 0.373100 diameter m 0.213 0.427150 diameter m 0.293 0.587200 diameter m 0.373 0.747250 diameter m 0.453 0.907300 diameter m 0.533 1.067350 diameter m 0.600 1.200400 diameter m 0.667 1.333450 diameter m 0.733 1.467500 diameter m 0.800 1.600600 diameter m 0.933 1.867750 diameter m 1.133 2.267900 diameter m 1.333 2.6671100 diameter m1200 diameter m1350 diameter m1500 diameter m
80 diameter m 0.187 0.373100 diameter m 0.213 0.427150 diameter m 0.293 0.587200 diameter m 0.373 0.747250 diameter m 0.453 0.907300 diameter m 0.533 1.067350 diameter m 0.600 1.200400 diameter m 0.667 1.333450 diameter m 0.733 1.467500 diameter m 0.800 1.600600 diameter m 0.933 1.867750 diameter m 1.133 2.267900 diameter m 1.333 2.6671100 diameter m1200 diameter m1350 diameter m1500 diameter m
sides, internally m2 0.178 0.357sides, externally m2 0.178 0.357roofs, top m2 0.178 0.357roofs, underside m2 0.178 0.357floors, m2 0.178 0.357
general surfaces; externally m2 0.333 0.667general surfaces; internally m2 0.333 0.667
Extra over pipework for valves:
Tanks
Vessels
Wet blast to existing surfaces
SA 2 SA 2 1/2
Structural metalwork; general surfaces
Structural metalwork; members of roof trusses etc
Services; pipes including flanges
232
M.2.4 Hand Preparation Hand preparation
ST 2 ST 3
Unit Norm Norm Norm Norm Norm Norm
girth over 300 m2 0.037 0.050 0.075 0.092 0.144 0.292isolated surfaces; girth up to 300 m 0.012 0.017 0.025 0.031 0.048 0.097
isolated areas; up to 0.50m2 Nr 0.037 0.050 0.075 0.092 0.144 0.292
girth over 300 m2 0.059 0.080 0.120 0.147 0.230 0.467isolated surfaces; girth up to 300 m 0.020 0.027 0.040 0.049 0.077 0.156
isolated areas; up to 0.50m2 Nr 0.059 0.080 0.120 0.147 0.230 0.467
up to 50 diameter m 0.018 0.024 0.036 0.044 0.069 0.14080 diameter m 0.021 0.028 0.042 0.052 0.081 0.164100 diameter m 0.024 0.032 0.048 0.059 0.092 0.187150 diameter m 0.033 0.044 0.066 0.081 0.127 0.257200 diameter m 0.041 0.056 0.084 0.103 0.161 0.327250 diameter m 0.050 0.068 0.102 0.125 0.196 0.397300 diameter m 0.059 0.080 0.120 0.147 0.230 0.467350 diameter m 0.067 0.090 0.135 0.166 0.259 0.526400 diameter m 0.074 0.100 0.150 0.184 0.288 0.584450 diameter m 0.081 0.110 0.165 0.202 0.317 0.642500 diameter m 0.089 0.120 0.180 0.221 0.346 0.701600 diameter m 0.104 0.140 0.210 0.258 0.403 0.818750 diameter m 0.126 0.170 0.255 0.313 0.490 0.993900 diameter m 0.148 0.200 0.300 0.368 0.576 1.1681100 diameter m 0.177 0.239 0.359 0.441 0.690 1.3981200 diameter m 0.189 0.255 0.383 0.470 0.735 1.4911350 diameter m 0.208 0.281 0.421 0.517 0.809 1.6401500 diameter m 0.226 0.305 0.457 0.561 0.878 1.781
80 diameter m 0.021 0.028 0.042 0.052 0.081 0.164100 diameter m 0.024 0.032 0.048 0.059 0.092 0.187150 diameter m 0.033 0.044 0.066 0.081 0.127 0.257200 diameter m 0.041 0.056 0.084 0.103 0.161 0.327250 diameter m 0.050 0.068 0.102 0.125 0.196 0.397300 diameter m 0.059 0.080 0.120 0.147 0.230 0.467350 diameter m 0.067 0.090 0.135 0.166 0.259 0.526400 diameter m 0.074 0.100 0.150 0.184 0.288 0.584450 diameter m 0.081 0.110 0.165 0.202 0.317 0.642500 diameter m 0.089 0.120 0.180 0.221 0.346 0.701600 diameter m 0.104 0.140 0.210 0.258 0.403 0.818750 diameter m 0.126 0.170 0.255 0.313 0.490 0.993900 diameter m 0.148 0.200 0.300 0.368 0.576 1.1681100 diameter m 0.177 0.239 0.359 0.441 0.690 1.3981200 diameter m 0.189 0.255 0.383 0.470 0.735 1.4911350 diameter m 0.208 0.281 0.421 0.517 0.809 1.6401500 diameter m 0.226 0.305 0.457 0.561 0.878 1.781
sides, internally m2 0.020 0.027 0.040 0.049 0.077 0.156sides, externally m2 0.020 0.027 0.040 0.049 0.077 0.156roofs, top m2 0.020 0.027 0.040 0.049 0.077 0.156roofs, underside m2 0.020 0.027 0.040 0.049 0.077 0.156floors, m2 0.020 0.027 0.040 0.049 0.077 0.156
general surfaces; externally m2 0.037 0.050 0.075 0.092 0.144 0.292general surfaces; internally m2 0.037 0.050 0.075 0.092 0.144 0.292
general surfaces m2 0.093 0.125 0.188 0.230 0.360 0.730Pumps, motors and the like
Structural metalwork; general surfaces
Structural metalwork; members of roof trusses etc
Services; pipes including flanges
Extra over pipework for valves:
Tanks
Vessels
Class 1 Surfaces
Class 1 Surfaces
Class 2 Surfaces
Class 3 Surfaces
Class 2 Surfaces
Class 3 Surfaces
233
M.2.5 Work Insitu on site to new & existing surface s – Application by brush or roller
Work insitu on site to new and existing surfaces - Application by brush or roller
Unit Norm/Coat Norm/Coat Norm/Coat
General Surfaces Girth over 300 m2 0.080 0.164 0.245Isolated Surfaces-Girth up to 300 m 0.024 0.049 0.074Isolated Areas-up to 0.50m2 Nr 0.080 0.164 0.245
Structural Metalwork-General Surfaces Girth over 300 m2 0.066 0.136 0.205Isolated Surfaces-Girth up to 300 m 0.022 0.045 0.068Isolated Areas-up to 0.50m2 Nr 0.066 0.136 0.205
Structural Metalwork-Members of Roof Trusses etc.Girth over 300 m2 0.106 0.218 0.327Isolated Surfaces-Girth up to 300 m 0.035 0.073 0.109Isolated Areas-up to 0.50m2 Nr 0.106 0.218 0.327
Services-Excluding PipesGirth over 300 m2 0.133 0.273 0.409Isolated Surfaces-Girth up to 300 m 0.044 0.091 0.136Isolated Areas-up to 0.50m2 Nr 0.133 0.273 0.409
Services-Pipes including FlangesUp to 50 diameter m 0.032 0.065 0.09880 diameter m 0.037 0.076 0.115100 diameter m 0.043 0.087 0.131150 diameter m 0.058 0.120 0.180200 diameter m 0.074 0.153 0.229250 diameter m 0.090 0.185 0.278300 diameter m 0.106 0.218 0.327350 diameter m 0.120 0.245 0.368400 diameter m 0.133 0.273 0.409450 diameter m 0.146 0.300 0.450500 diameter m 0.159 0.327 0.491600 diameter m 0.186 0.382 0.573750 diameter m 0.226 0.464 0.695900 diameter m 0.266 0.545 0.8181100 diameter m 0.318 0.652 0.9791200 diameter m 0.339 0.695 1.0441350 diameter m 0.373 0.765 1.1481500 diameter m 0.406 0.831 1.247
Extra over pipework for valves:80 diameter m 0.037 0.076 0.115100 diameter m 0.043 0.087 0.131150 diameter m 0.058 0.120 0.180200 diameter m 0.074 0.153 0.229250 diameter m 0.090 0.185 0.278300 diameter m 0.106 0.218 0.327350 diameter m 0.120 0.245 0.368400 diameter m 0.133 0.273 0.409450 diameter m 0.146 0.300 0.450500 diameter m 0.159 0.327 0.491600 diameter m 0.186 0.382 0.573750 diameter m 0.226 0.464 0.695900 diameter m 0.266 0.545 0.8181100 diameter m 0.318 0.652 0.9791200 diameter m 0.339 0.695 1.0441350 diameter m 0.373 0.765 1.1481500 diameter m 0.406 0.831 1.247
TanksSides-Externally m2 0.036 0.073 0.109Roofs-Top m2 0.036 0.073 0.109
VesselsGeneral Surfaces-Externally m2 0.066 0.136 0.205
Pumps, Motors and the likeGeneral Surfaces m2 0.166 0.341 0.511
SpheresGeneral Surfaces Externally m2 0.036 0.073 0.109
General Coatings High Build CoatingsUp to 125 Microns
DFT>126 upto
250 microns>251 upto
500 microns
234
M.2.6 Work on site or in a dedicated painting facil ity – Spray application
Work on site or in a dedicated painting facility - Spray application
Norm/Coat
General Surfaces Girth over 300 m2 0.040Isolated Surfaces-Girth up to 300 m 0.012Isolated Areas-up to 0.50m2 Nr 0.040
Structural Metalwork-General Surfaces Girth over 300 m2 0.033Isolated Surfaces-Girth up to 300 m 0.011Isolated Areas-up to 0.50m2 Nr 0.033
Structural Metalwork-Members of Roof Trusses etc.Girth over 300 m2 0.053Isolated Surfaces-Girth up to 300 m 0.018Isolated Areas-up to 0.50m2 Nr 0.053
Services-Excluding PipesGirth over 300 m2 0.066Isolated Surfaces-Girth up to 300 m 0.022Isolated Areas-up to 0.50m2 Nr 0.066
Services-Pipes including FlangesUp to 50 diameter m 0.01680 diameter m 0.019100 diameter m 0.021150 diameter m 0.029200 diameter m 0.037250 diameter m 0.045300 diameter m 0.053350 diameter m 0.060400 diameter m 0.066450 diameter m 0.073500 diameter m 0.080600 diameter m 0.093750 diameter m 0.113900 diameter m 0.1331100 diameter m 0.1591200 diameter m 0.1701350 diameter m 0.1871500 diameter m 0.203
Extra over pipework for valves:80 diameter m 0.019100 diameter m 0.021150 diameter m 0.029200 diameter m 0.037250 diameter m 0.045300 diameter m 0.053350 diameter m 0.060400 diameter m 0.066450 diameter m 0.073500 diameter m 0.080600 diameter m 0.093750 diameter m 0.113900 diameter m 0.1331100 diameter m 0.1591200 diameter m 0.1701350 diameter m 0.1871500 diameter m 0.203
TanksSides-Externally m2 0.018Roofs-Top m2 0.018
VesselsGeneral Surfaces-Externally m2 0.033
Pumps, Motors and the likeGeneral Surfaces m2 0.083
SpheresGeneral Surfaces Externally m2 0.018
General Up to 500 Microns
DFT
235
M.2.7 Work on site or in dedicated painting facilit y – Spray application (incl. remedials)
Norm/Coat
General Surfaces General Surfaces - Externally m2 0.094
Services-Excluding PipesGeneral Surfaces - Externally m2 0.134
Services-Pipes including FlangesUp to 50 diameter m 0.03280 diameter m 0.037100 diameter m 0.043150 diameter m 0.058200 diameter m 0.074250 diameter m 0.090300 diameter m 0.106350 diameter m 0.120400 diameter m 0.133450 diameter m 0.146500 diameter m 0.159600 diameter m 0.186750 diameter m 0.226900 diameter m 0.2661100 diameter m 0.3181200 diameter m 0.3391350 diameter m 0.3731500 diameter m 0.406
Extra over pipework for valves:80 diameter m 0.037100 diameter m 0.043150 diameter m 0.058200 diameter m 0.074250 diameter m 0.090300 diameter m 0.106350 diameter m 0.120400 diameter m 0.133450 diameter m 0.146500 diameter m 0.159600 diameter m 0.186750 diameter m 0.226900 diameter m 0.2661100 diameter m 0.3181200 diameter m 0.3391350 diameter m 0.3731500 diameter m 0.406
TanksGeneral Surfaces - Externally m2 0.036
VesselsGeneral Surfaces-Externally m2 0.066
Pumps, Motors and the likeGeneral Surfaces-Externally m2 0.166
SpheresGeneral Surfaces Externally m2 0.036
General CoatingsUp to 500 Microns
DFT
Work on site or in a dedicated painting facility - Spray application (including Remedials)
236
O.1 Cleaning Norms
O.2.1 Vessels & Column Cleaning
Vessel Cleaning
Item Unit Low Medium High
Brushing of shell seams m 0.03 0.05 0.75
Brushing of Nozzle Seams, Cleaning of Nozzles No. 0.03 0.05 0.75
Cleaning of Shell Surface m² 0.09 0.15 0.23
Vessel
Fouling Level
Column Cleaning
Item Unit
Hrs Hrs Hrs
Brushing of shell seams m 0.04 0.06 0.08
Brushing of Support Ring Seams m 0.04 0.06 0.08
Brushing of Clamp Strip Seams m 0.04 0.06 0.08
Brushing of Nozzle Seams, Cleaning of Nozzles No. 0.04 0.06 0.08
Cleaning of Shell Surface m² 0.13 0.18 0.23
Cleaning of Column Tray Surface Area m² 0.17 0.24 0.30
Cleaning of Runoff Plates m² 0.09 0.12 0.15
Cleaning of Anti-Flow Plates No. 0.28 0.40 0.50
Low Medium High
Columns
Fouling Level
237
Vessel / Column Cleaning
Item Unit Hrs
Cleaning of Demisters No. 0.50
Washing of Fillers m³ 5.00
Cleaning of Partition Walls No. 1.00
Cleaning of Filters / Small Vessels No. 0.50
Cleaning of Filter Inserts, Straines, etc. No. 0.15
General
All Fouling Levels
238
O.2.2 Tank Cleaning - Removal of content: pumpable liquid/sludge
Description Unit Hrs Hrs Hrs
Removal of residual product (free liquid)
Tanks 0 to <15m (0' to <50') m3 0.22 0.31 0.40
Tanks 15 to <30m (50' to <100') m3 0.22 0.31 0.40
Tanks 30 to <45m (100' to <150') m3 0.22 0.31 0.40
Removal of pumpable sludge - without Steam Coils
Tanks 0 to <15m (0' to <50') m3 0.88 1.10 1.32
Tanks 15 to <30m (50' to <100') m3 0.88 1.10 1.32
Tanks 30 to <45m (100' to <150') m3 0.88 1.10 1.32
Removal of pumpable sludge - with Steam Coils
Tanks 0 to <15m (0' to <50') m3 1.10 1.32 1.54
Tanks 15 to <30m (50' to <100') m3 1.10 1.32 1.54
Tanks 30 to <45m (100' to <150') m3 1.10 1.32 1.54
FOULING LEVEL
HighMediumLow
239
O.2.3 Tank Cleaning - Removal of content: non-pumpa ble liquid/sludge
All Types
Description Unit Hrs
Removal of non-pumpable sludge - no Steam Coils
Tanks 0 to <15m (0' to <50') m3 5.97
Tanks 15 to <30m (50' to <100') m3 5.97
Tanks 30 to <45m (100' to <150') m3 5.97
Removal of non-pumpable sludge - with Steam Coils
Tanks 0 to <15m (0' to <50') m3 7.18
Tanks 15 to <30m (50' to <100') m3 7.18
Tanks 30 to <45m (100' to <150') m3 8.36
FOULING LEVEL
240
O.2.4 Tank Cleaning - washing
Description Unit Hrs Hrs Hrs
Hydroblast tank interior (walls, roof, floor, etc)
Any size tank - no Steam Coils m2 0.07 0.08 0.08
Any size tank - with Steam Coils m2 0.07 0.08 0.08
Water wash tank interior (walls, roof, floor, etc)
Tanks 0 to <15m (0' to <50') No. 32.50 32.50 32.50
Tanks 15 to <30m (50' to <100') No. 50.00 50.00 50.00
Tanks 30 to <45m (100' to <150') No. 75.00 75.00 75.00
Water wash tank interior post-hydrotest
Tanks 0 to <15m (0' to <50') No. 20.00 20.00 20.00
Tanks 15 to <30m (50' to <100') No. 37.50 37.50 37.50
Tanks 30 to <45m (100' to <150') No. 50.00 50.00 50.00
FOULING LEVEL
Low Medium High
241
O.2.5 Hydro-cutting tank shell
Description Unit Hrs
n.e. 6mm (1/4") Wall Thickness m 1.64
Over 6mm (1/4") n.e. 12mm (1/2") Wall Thickness m 2.08
Over 12mm (1/2") n.e. 20mm (3/4") Wall Thickness m 2.85
Carbon Steel
O.2.6 Pipework Cleaning
Fouling Level Scrapping Operational Inspection
NB in inches Hrs per m Hrs per m Hrs per m
3" & under 0.19 0.25 0.37
Over 3" n.e. 6" 0.28 0.37 0.56
Over 6" n.e. 10" 0.38 0.51 0.76
Over 10" n.e. 16" 0.43 0.57 0.86
18" 0.48 0.64 0.96
Over 18" n.e. 24" 0.53 0.70 1.05
Over 24" n.e. 28" 0.62 0.83 1.24
Over 28" n.e. 32" 0.72 0.96 1.44
CLEAN in DESIGNATED AREA
242
O.2.7 Floating Head & “U” Tube Exchangers - Bundle Only - Tube Side Only (Int.)
Cleanliness Level
No of Tubes Unit Hrs per bundle Hrs per bundle Hrs per bundle
1-50 No. 0.56 0.70 0.91
51-100 No. 1.05 1.40 1.75
101-200 No. 2.10 2.80 3.50
201-400 No. 4.20 5.60 7.00
401-600 No. 6.30 8.40 10.50
601-800 No. 8.40 11.20 14.00
801-1000 No. 10.50 14.00 17.50
1001-1200 No. 12.60 16.80 21.00
1201-1400 No. 14.70 19.60 24.50
1401-1600 No. 16.80 22.40 28.00
1601-1800 No. 18.90 25.20 31.50
1801-2000 No. 21.00 28.00 35.00
2001-2200 No. 23.10 30.80 38.50
2201-2400 No. 25.20 33.60 42.00
CLEAN in DESIGNATED AREA
Tube length n.e. 3.66m (12')
Scrapping Operational Inspection (10% Iris)
243
Cleanliness Level
No of Tubes Unit Hrs per bundle Hrs per bundle Hrs per bundle
1-50 No. 0.63 0.91 1.12
51-100 No. 1.33 1.75 2.24
101-200 No. 2.59 3.50 4.41
201-400 No. 5.25 7.00 9.10
401-600 No. 7.70 10.50 13.30
601-800 No. 10.50 14.00 17.50
801-1000 No. 13.30 17.50 22.40
1001-1200 No. 15.40 21.00 26.60
1201-1400 No. 18.20 24.50 30.80
1401-1600 No. 21.00 28.00 35.70
1601-1800 No. 23.80 31.50 39.90
1801-2000 No. 25.90 35.00 44.10
2001-2200 No. 28.49 38.50 48.51
2201-2400 No. 31.08 42.00 52.92
CLEAN in DESIGNATED AREA
Tube length over 3.66m (12') n.e. 4.88m (16')
Scrapping Operational Inspection (10% Iris)
244
Cleanliness Level
No of Tubes Unit Hrs per bundle Hrs per bundle Hrs per bundle
1-50 No. 0.77 1.05 1.33
51-100 No. 1.54 2.10 2.66
101-200 No. 3.15 4.20 5.39
201-400 No. 6.23 8.40 10.50
401-600 No. 9.10 12.60 16.10
601-800 No. 12.60 16.80 21.70
801-1000 No. 15.40 21.00 26.60
1001-1200 No. 18.90 25.20 32.20
1201-1400 No. 22.05 29.40 37.80
1401-1600 No. 25.20 33.60 42.70
1601-1800 No. 28.00 37.80 48.30
1801-2000 No. 31.50 42.00 53.90
2001-2200 No. 34.65 46.20 59.29
2201-2400 No. 37.80 50.40 64.68
CLEAN in DESIGNATED AREA
Tube length over 4.88m (16') n.e. 6.10m (20')
Scrapping Operational Inspection (10% Iris)
245
O.2.8 Floating Head & “U” Tube Exchangers - Bundle Only - Shell Side Only (Ext.)
Cleanliness Level
No of Tubes Unit Hrs per bundle Hrs per bundle Hrs per bundle
1-50 No. 0.28 0.35 0.46
51-100 No. 0.53 0.70 0.88
101-200 No. 1.05 1.40 1.75
201-400 No. 2.10 2.80 3.50
401-600 No. 3.15 4.20 5.25
601-800 No. 4.20 5.60 7.00
801-1000 No. 5.25 7.00 8.75
1001-1200 No. 6.30 8.40 10.50
1201-1400 No. 7.35 9.80 12.25
1401-1600 No. 8.40 11.20 14.00
1601-1800 No. 9.45 12.60 15.75
1801-2000 No. 10.50 14.00 17.50
2001-2200 No. 11.55 15.40 19.25
2201-2400 No. 12.60 16.80 21.00
CLEAN in DESIGNATED AREA
Tube length n.e. 3.66m (12')
Scrapping Operational Inspection (10% Iris)
246
Cleanliness Level
No of Tubes Unit Hrs per bundle Hrs per bundle Hrs per bundle
1-50 No. 0.32 0.46 0.56
51-100 No. 0.67 0.88 1.12
101-200 No. 1.30 1.75 2.21
201-400 No. 2.63 3.50 4.55
401-600 No. 3.85 5.25 6.65
601-800 No. 5.25 7.00 8.75
801-1000 No. 6.65 8.75 11.20
1001-1200 No. 7.70 10.50 13.30
1201-1400 No. 9.10 12.25 15.40
1401-1600 No. 10.50 14.00 17.85
1601-1800 No. 11.90 15.75 19.95
1801-2000 No. 12.95 17.50 22.05
2001-2200 No. 14.25 19.25 24.26
2201-2400 No. 15.54 21.00 26.46
CLEAN in DESIGNATED AREA
Tube length over 3.66m (12') n.e. 4.88m (16')
Scrapping Operational Inspection (10% Iris)
247
Cleanliness Level
No of Tubes Unit Hrs per bundle Hrs per bundle Hrs per bundle
1-50 No. 0.39 0.53 0.67
51-100 No. 0.77 1.05 1.33
101-200 No. 1.58 2.10 2.70
201-400 No. 3.12 4.20 5.25
401-600 No. 4.55 6.30 8.05
601-800 No. 6.30 8.40 10.85
801-1000 No. 7.70 10.50 13.30
1001-1200 No. 9.45 12.60 16.10
1201-1400 No. 11.03 14.70 18.90
1401-1600 No. 12.60 16.80 21.35
1601-1800 No. 14.00 18.90 24.15
1801-2000 No. 15.75 21.00 26.95
2001-2200 No. 17.33 23.10 29.65
2201-2400 No. 18.90 25.20 32.34
CLEAN in DESIGNATED AREA
Tube length over 4.88m (16') n.e. 6.10m (20')
Scrapping Operational Inspection (10% Iris)
248
O.2.9 Floating Head & “U” Tube Exchangers - Shell
Exchanger Head Assembly
Cleanliness Level
Diameter Unit Hrs per Head Hrs per Head Hrs per Head
<500mm No. 0.47 0.63 0.79
501-1000mm No. 0.58 0.78 0.98
1001-1500mm No. 0.93 1.25 1.58
1501-2000mm No. 1.15 1.56 1.97
>2001mm No. 1.27 1.72 2.17
Exchanger Bodies
Cleanliness Level
Diameter Unit Hrs per Body Hrs per Body Hrs per Body
<500mm No. 3.89 5.25 6.62
501-1000mm No. 4.44 6.00 7.56
1001-1500mm No. 5.55 7.50 9.45
1501-2000mm No. 6.48 8.75 11.03
>2001mm No. 7.03 9.50 11.97
Scrapping Operational Inspection (10% Iris)
CLEAN in DESIGNATED AREA
CLEAN in DESIGNATED AREA
Scrapping Operational Inspection (10% Iris)
249
O.2.10 Fixed Tubesheet Exchangers
Tube Side Only (internal) - including both tubeshee ts and end covers
Cleanliness Level
No of Tubes Unit Hrs per bundle Hrs per bundle Hrs per bundle
1-50 No. 0.88 1.05 1.23
51-100 No. 1.40 1.75 2.10
101-200 No. 2.45 3.15 3.85
201-400 No. 4.55 5.95 7.35
401-600 No. 6.65 8.75 10.85
601-800 No. 8.75 11.55 14.35
801-1000 No. 10.85 14.35 17.85
1001-1200 No. 13.30 17.50 21.70
1201-1400 No. 15.40 20.30 25.20
1401-1600 No. 17.50 23.10 28.70
1601-1800 No. 19.60 25.90 32.20
1801-2000 No. 21.70 28.70 35.70
2001-2200 No. 23.87 31.57 39.27
2201-2400 No. 26.04 34.44 42.84
CLEAN in DESIGNATED AREA
Tube length n.e. 3.66m (12')
Inspection (10% Iris)
OperationalScrapping
250
Tube Side Only (internal) - including both tubeshee ts and end covers
Cleanliness Level
No of Tubes Unit Hrs per bundle Hrs per bundle Hrs per bundle
1-50 No. 1.00 1.23 1.46
51-100 No. 1.91 2.10 2.57
101-200 No. 2.96 3.85 4.78
201-400 No. 5.58 7.35 9.24
401-600 No. 8.19 10.85 13.65
601-800 No. 10.78 14.35 18.06
801-1000 No. 13.44 17.85 22.54
1001-1200 No. 16.38 21.70 27.30
1201-1400 No. 18.97 25.20 31.71
1401-1600 No. 21.63 28.70 36.19
1601-1800 No. 24.22 32.20 40.60
1801-2000 No. 26.81 35.70 45.01
2001-2200 No. 29.49 39.27 49.51
2201-2400 No. 32.17 42.84 54.01
CLEAN in DESIGNATED AREA
Tube length over 3.66m (12') n.e. 4.88m (16')
Inspection (10% Iris)
OperationalScrapping
251
Tube Side Only (internal) - including both tubeshee ts and end covers
Cleanliness Level
No of Tubes Unit Hrs per bundle Hrs per bundle Hrs per bundle
1-50 No. 1.13 1.40 1.69
51-100 No. 1.91 2.45 3.03
101-200 No. 3.48 4.55 5.72
201-400 No. 6.60 8.75 11.06
401-600 No. 9.73 12.95 16.45
601-800 No. 12.88 17.15 21.84
801-1000 No. 15.96 21.35 27.16
1001-1200 No. 19.46 25.90 32.90
1201-1400 No. 22.61 30.10 38.29
1401-1600 No. 25.69 34.30 43.61
1601-1800 No. 28.84 38.50 49.00
1801-2000 No. 31.99 42.70 54.39
2001-2200 No. 35.19 46.97 59.83
2201-2400 No. 38.39 51.24 65.27
CLEAN in DESIGNATED AREA
Tube length over 4.88m (16') n.e. 6.10m (20')
Scrapping Operational Inspection (10% Iris)
252
O.2.11 Air Fin Coolers Tube Side Only (internal) - including both tubesheets and covers
Inspection Level
No of Tubes Unit Hrs per bundle m Hrs per bundle m Hrs per bundle m
1-50 m 0.20 0.20 0.26
51-100 m 0.29 0.39 0.49
101-200 m 0.61 0.77 1.01
201-300 m 0.91 1.19 1.47
301-400 m 1.19 1.56 1.93
401-500 m 1.47 1.93 2.48
501-600 m 1.75 2.30 2.94
601-700 m 2.11 2.66 3.40
701-800 m 2.39 3.12 3.95
801-1000 m 2.94 3.86 4.87
External Surface
Plan Area Unit Hrs per Cooler
< 5m2 No. 6.35
over 5 n.e. 10m2 No. 11.69
over 10 n.e. 15m2 No. 20.30
over 15 n.e. 25m2 No. 27.15
CLEAN in DESIGNATED AREA
CLEAN in DESIGNATED
Scrapping Operational 10% Iris
253
P.1 Tankage Norms
P.2.1 Cone Roofs & Internal/External Floating Roofs
P.2.1.1 Demolition Work
51.151.1.1 Demolition Work Demolition Work51.1.11 Cone Roof Removal Cone Roof Removal51.1.11a Tanks less than or equal to 50' in diameter SF 0.0851 Tanks less than or equal to 15m in diameter SM 0.915951.1.11b Tanks 51' - 90' in diameter SF 0.0709 Tanks 15m - 30m in diameter SM 0.7632
51.1.11c Tanks 91' - 125' in diameter SF 0.0567 Tanks 30m - 40m in diameter SM 0.6104
51.1.11d Tanks 126' - 160' in diameter SF 0.0425 Tanks 40m - 50m in diameter SM 0.4575
51.1.11e Tanks 160' - 190' in diameter SF 0.0370 Tanks 50m - 60m in diameter SM 0.3983
51.1.11f Tanks 191' - 220' in diameter SF 0.0315 Tanks 60m - 70m in diameter SM 0.3391
51.1.11g Tanks greater than 221' in diameter SF 0.0284 Tanks greater than 70m in diameter SM 0.3056
51.1.12 Pontoon Roof Removal - Single Deck Pontoon Roof Removal - Single Deck51.1.12a Tanks less than or equal to 50' in diameter SF 0.1063 Tanks less than or equal to 15m in diameter SM 1.144151.1.12b Tanks 51' - 90' in diameter SF 0.0921 Tanks 15m - 30m in diameter SM 0.9914
51.1.12c Tanks 91' - 125' in diameter SF 0.0780 Tanks 30m - 40m in diameter SM 0.8395
51.1.12d Tanks 126' - 160' in diameter SF 0.0638 Tanks 40m - 50m in diameter SM 0.6867
51.1.12e Tanks 160' - 190' in diameter SF 0.0580 Tanks 50m - 60m in diameter SM 0.6242
51.1.12f Tanks 191' - 220' in diameter SF 0.0511 Tanks 60m - 70m in diameter SM 0.5501
51.1.12g Tanks greater than 221' in diameter SF 0.0496 Tanks greater than 70m in diameter SM 0.5340
51.1.13 Pontoon Roof Removal - Double Deck Pontoon Roof Removal - Double Deck51.1.13a Tanks less than or equal to 50' in diameter SF 0.1347 Tanks less than or equal to 15m in diameter SM 1.449851.1.13b Tanks 51' - 90' in diameter SF 0.1205 Tanks 15m - 30m in diameter SM 1.2969
51.1.13c Tanks 91' - 125' in diameter SF 0.0992 Tanks 30m - 40m in diameter SM 1.0678
51.1.13d Tanks 126' - 160' in diameter SF 0.0851 Tanks 40m - 50m in diameter SM 0.9161
51.1.13e Tanks 160' - 190' in diameter SF 0.0774 Tanks 50m - 60m in diameter SM 0.8331
51.1.13f Tanks 191' - 220' in diameter SF 0.0689 Tanks 60m - 70m in diameter SM 0.7415
51.1.13g Tanks greater than 221' in diameter SF 0.0638 Tanks greater than 70m in diameter SM 0.6866
CONE ROOFS & INTERNAL/EXTERNAL FLOATING ROOFS CONE R OOFS & INTERNAL/EXTERNAL FLOATING ROOFS
Reference Number
Task Description for Metric Work
Productivity Factor - IMPERIAL
Units Base Norm
Productivity Factor - METRIC
Units Base Norm
Task Description for Imperial Work
254
51.1.1451.1.14a less than 3" roof penetrations EA 1.4176 less than 80mm roof penetrations EA 1.4176
51.1.14b 3" - 6" roof penetrations EA 2.1264 80mm - 150mm roof penetrations EA 2.1264
51.1.14c 6" - 8" roof penetrations EA 2.4808 1500mm - 200mm roof penetrations EA 2.4808
51.1.14d 8" - 10" roof penetrations EA 2.8351 200mm - 250mm roof penetrations EA 2.8351
51.1.14e 10" - 12" roof penetrations EA 3.1895 250mm - 300mm roof penetrations EA 3.1895
51.1.14f 12" - 14" roof penetrations EA 3.5439 300mm - 350mm roof penetrations EA 3.5439
51.1.14g 14" - 18" roof penetrations EA 3.8983 350mm - 450mm roof penetrations EA 3.8983
51.1.14h 18" - 24" roof penetrations EA 4.2527 450mm - 600mm roof penetrations EA 4.2527
51.1.14i greater than 24" roof penetrations EA 7.8750 greater than 600mm roof penetrations EA 7.8750
51.1.15 Removal of rafter beams Removal of rafter beams51.1.15a Removal of rafter beams with roof plates removed. LBS 0.0106 Removal of rafter beams with roof plates removed. KG 0.0233
51.1.15b Removal of rafter beams with roof plates in place. LBS 0.0213 Removal of rafter beams with roof plates in place. KG 0.0469
51.1.16 Remove / Reinstall daylight sheets Remove / Reinstall daylight sheets51.1.16a Removal of roof plate for ventilation and light. EA 11.3406 Removal of roof plate for ventilation and light. EA 11.3406
51.1.16b Reinstallation of roof plate. EA 22.6811 Reinstallation of roof plate. EA 22.6811
51.1.17 Rehandling Scrap Material Rehandling Scrap Material
51.1.17aRehandling Scrap Material due to non provision of scrap boxes (Skips / Dumpsters)
LBS 0.0014Rehandling Scrap Material due to non provision of scrap boxes (Skips / Dumpsters)
KG 0.0031
51.1.18 Removal of Covers and Hatches - (any size) Removal of Covers and Hatches - (any size)51.1.18a Removal of Covers and Hatches - (any size) EA 1.4176 Removal of Covers and Hatches - (any size) EA 1.4176
Removal of Roof Penetrations (not associated with r oof removal) Removal of Roof Penetrations (not assoc iated with roof removal)
255
P.2.1.2 Roof Plate & Roof Structure Installation 51.1
51.1.2 Roof Plate and Roof Structure Installation Roof Plate and Roof Structure Installation
51.1.21
51.1.2101 Tanks less than or equal to 50' in diameter SF 0.1625 Tanks less than or equal to 15m in diameter SM 1.7491
51.1.2102 Tanks 51' - 90' in diameter SF 0.1258 Tanks 15m - 30m in diameter SM 1.3540
51.1.2103 Tanks 91' - 125' in diameter SF 0.1008 Tanks 30m - 40m in diameter SM 1.0850
51.1.2104 Tanks 126' - 160' in diameter SF 0.0931 Tanks 40m - 50m in diameter SM 1.0022
51.1.2105 Tanks 160' - 190' in diameter SF 0.0894 Tanks 50m - 60m in diameter SM 0.9622
51.1.2106 Tanks 191' - 220' in diameter SF 0.0872 Tanks 60m - 70m in diameter SM 0.9387
51.1.2107 Tanks greater than 221' in diameter SF 0.0419 Tanks greater than 70m in diameter SM 0.4510
51.1.2108 Conversion from frangible to nonfrangible roof joint SF 0.0709 Conversion from frangible to nonfrangible roof joint SM 0.2326
51.1.2109 Pressurized air testing per API 650 SF 0.0170 Pressurized air testing per specification SM 0.1830
51.1.22
51.1.2201 Tanks less than or equal to 50' in diameter SF 0.1713 Tanks less than or equal to 15m in diameter SM 1.8438
51.1.2202 Tanks 51' - 90' in diameter SF 0.1346 Tanks 15m - 30m in diameter SM 1.4488
51.1.2203 Tanks 91' - 125' in diameter SF 0.1093 Tanks 30m - 40m in diameter SM 1.1764
51.1.2204 Tanks 126' - 160' in diameter SF 0.1016 Tanks 40m - 50m in diameter SM 1.0937
51.1.2205 Tanks 160' - 190' in diameter SF 0.0996 Tanks 50m - 60m in diameter SM 1.0721
51.1.2206 Tanks 191' - 220' in diameter SF 0.0966 Tanks 60m - 70m in diameter SM 1.0398
51.1.2207 Tanks greater than 221' in diameter SF 0.0946 Tanks greater than 70m in diameter SM 1.0182
51.1.2208 Conversion from frangible to nonfrangible roof joint SF 0.0709 Conversion from frangible to nonfrangible SM 0.2326
51.1.2209 Pressurized air testing per API 650 SF 0.0170 Pressurized air testing per specification SM 0.1830
51.1.23 Field Fit-up and install new roof rafters Field Fit-up and install new roof rafters
51.1.23a Fabrication and installation of rafter beams with roof plate removed. LBS 0.0148 Fabrication and installation of rafter beams with roof plate removed. KG 0.0325
51.1.23b Fabrication and installation of rafter beams with roof plate in place. LBS 0.0269 Fabrication and installation of rafter beams with roof plate in place. KG 0.0593
Fabricate and install new roof plates using 1/4" C. S. plate, per API 650, API 653
Fabricate and install new roof plates using 6mm C.S . plate, per API 650, API 653
CONE ROOFS & INTERNAL/EXTERNAL FLOATING ROOFS
Fabricate and install new roof plates using 3/16" C .S. plate, per API 650, API 653
Fabricate and install new roof plates using 5mm C.S . plate, per API 650, API 653
CONE ROOFS & INTERNAL/EXTERNAL FLOATING ROOFS
256
51.1.2451.1.2401 Tanks less than or equal to 50' in diameter SF 0.7780 Tanks less than or equal to 15m in diameter SM 8.3739
51.1.2402 Tanks 51' - 90' in diameter SF 0.3090 Tanks 15m - 30m in diameter SM 3.3259
51.1.2403 Tanks 91' - 125' in diameter SF 0.2312 Tanks 30m - 40m in diameter SM 2.4885
51.1.2404 Tanks 126' - 160' in diameter SF 0.2137 Tanks 40m - 50m in diameter SM 2.3002
51.1.2405 Tanks 160' - 190' in diameter SF 0.2094 Tanks 50m - 60m in diameter SM 2.2538
51.1.2406 Tanks 191' - 220' in diameter SF 0.2062 Tanks 60m - 70m in diameter SM 2.2195
51.1.2407 Tanks greater than 221' in diameter SF 0.2061 Tanks greater than 70m in diameter SM 2.2183
51.1.2551.1.2501 Tanks less than or equal to 50' in diameter SF 0.8254 Tanks less than or equal to 15m in diameter SM 8.8841
51.1.2502 Tanks 51' - 90' in diameter SF 0.3929 Tanks 15m - 30m in diameter SM 4.2290
51.1.2503 Tanks 91' - 125' in diameter SF 0.3230 Tanks 30m - 40m in diameter SM 3.4767
51.1.2504 Tanks 126' - 160' in diameter SF 0.3044 Tanks 40m - 50m in diameter SM 3.2764
51.1.2505 Tanks 160' - 190' in diameter SF 0.2862 Tanks 50m - 60m in diameter SM 3.0804
51.1.2506 Tanks 191' - 220' in diameter SF 0.2662 Tanks 60m - 70m in diameter SM 2.8651
51.1.2507 Tanks greater than 221' in diameter SF 0.2475 Tanks greater than 70m in diameter SM 2.6639
Fabricate and install new Double Deck Pontoon Roof Fabricate and install new Double Deck Pontoon Roo f
Fabricate and install new Single Deck Pontoon Roof F abricate and install new Single Deck Pontoon Roof
257
P.2.1.3 Roof Manways & Nozzles 51.1
51.1.3 Roof Manways and Nozzles Roof Manways and Nozzles51.1.3151.1.3101 less than 2" roof nozzles EA 4.7131 less than 50mm roof nozzles EA 4.7131
51.1.3102 2" roof nozzles EA 5.4219 50mm roof nozzles EA 5.4219
51.1.3103 3" roof nozzles EA 5.9387 80mm roof nozzles EA 5.9387
51.1.3104 4" roof nozzles EA 7.3735 100mm roof nozzles EA 7.3735
51.1.3105 5" roof nozzles EA 7.6975 125mm roof nozzles EA 7.6975
51.1.3106 6" roof nozzles EA 8.0215 150mm roof nozzles EA 8.0215
51.1.3107 8" roof nozzles EA 15.6583 200mm roof nozzles EA 15.6583
51.1.3108 10" roof nozzles EA 17.9222 250mm roof nozzles EA 17.9222
51.1.3109 12" roof nozzles EA 20.1861 300mm roof nozzles EA 20.1861
51.1.3110 14" roof nozzles EA 22.4791 350mm roof nozzles EA 22.4791
51.1.3111 16" roof nozzles EA 24.7721 400mm roof nozzles EA 24.7721
51.1.3112 18" roof nozzles EA 27.2584 450mm roof nozzles EA 27.2584
51.1.3113 20" roof nozzles EA 30.1251 500mm roof nozzles EA 30.1251
51.1.3114 22" roof nozzles EA 32.7062 550mm roof nozzles EA 32.7062
51.1.3115 24" roof nozzles EA 35.2873 600mm roof nozzles EA 35.2873
51.1.3116 24" Varec Gauge hatch nozzle EA 25.9085 600mm Varec Gauge hatch nozzle EA 25.9085
51.1.3117 20" roof manway hatch EA 25.9636 500mm roof manway hatch EA 25.9636
51.1.3118 24" roof manway hatch EA 31.4830 600mm roof manway hatch EA 31.4830
51.1.3251.1.32a less than 2" roof nozzles EA 3.5429 less than 50mm roof nozzles EA 3.5429
51.1.32b 2" roof nozzles EA 4.2527 50mm roof nozzles EA 4.2527
51.1.32c 3" roof nozzles EA 4.2527 80mm roof nozzles EA 4.2527
51.1.32d 4" roof nozzles EA 4.9615 100mm roof nozzles EA 4.9615
51.1.32e 5" roof nozzles EA 4.9615 125mm roof nozzles EA 4.9615
51.1.32f 6" roof nozzles EA 4.9615 150mm roof nozzles EA 4.9615
51.1.22g 8" roof nozzles EA 14.1757 200mm roof nozzles EA 14.1757
51.1.32h 10" roof nozzles EA 15.5933 250mm roof nozzles EA 15.5933
51.1.32i 12" roof nozzles EA 17.0108 300mm roof nozzles EA 17.0108
51.1.32j 14" roof nozzles EA 18.4284 350mm roof nozzles EA 18.4284
51.1.32k 16" roof nozzles EA 19.8460 400mm roof nozzles EA 19.8460
51.1.32l 18" roof nozzles EA 21.2636 450mm roof nozzles EA 21.2636
51.1.32m 20" roof nozzles EA 22.6811 500mm roof nozzles EA 22.6811
51.1.32n 22" roof nozzle EA 24.0987 550mm roof nozzles EA 24.0987
51.1.32o 24" roof nozzle EA 25.5163 600mm roof nozzles EA 25.5163
51.1.32p 24" Varec Gauge hatch nozzle. EA 17.0108 600mm Varec Gauge hatch nozzle EA 17.0108
51.1.32q 20" roof manway hatch EA 12.7581 500mm roof manway hatch EA 12.7581
51.1.32r 24" roof manway hatch EA 15.5933 600mm roof manway hatch EA 15.5933
Install reclaimed roof manways, hatches, and nozzle s Install reclaimed roof manways, hatches, and nozzl es
Fabricate and install new roof manways, hatches, an d nozzles
CONE ROOFS & INTERNAL/EXTERNAL FLOATING ROOFS CONE R OOFS & INTERNAL/EXTERNAL FLOATING ROOFS
Fabricate and install new roof manways, hatches, an d nozzles
258
51.1.3351.1.33a Replace complete assembly. EA 17.4477 Replace complete assembly. EA 17.4477
51.1.33b Replace sleeve assembly only. EA 6.5915 Replace sleeve assembly only. EA 6.5915
51.1.33c Replace gasket/seal only. EA 0.7088 Replace gasket/seal only. EA 0.7088
51.1.33d Replace external sleeve gussets only. EA 2.8351 Replace external sleeve gussets only. EA 2.8351
51.1.33e Replace vent breaker mechanism complete. EA 10.8562 Replace vent breaker mechanism complete. EA 10.8562
51.1.33f Replace vent breaker adjustable leg. EA 11.5650 Replace vent breaker adjustable leg. EA 11.5650
51.1.33g Replace vent breaker EA 11.5650 Replace vent breaker EA 11.5650
Replace Floating Roof Mechanical Vacuum Vents/Break ers (Refer to Replace Floating Roof Mechanical Vacu um Vents/Breakers (Refer to
259
P.2.1.4 Lap Patching (Overplate) 51.1
51.1.4 Lap Patching (Overplate) Lap Patching (Overplate)51.1.41 Lap Patch 1/4" C.S. plate Lap Patch 6mm C.S. plate
51.1.41A Lap patches 5 sq ft or less Lap patches 0.5 sq m or less51.1.41a01 Quantity 1 - 5 LF 0.5245 Quantity 1 - 5 LM 1.7208
51.1.41a02 Quantity 6 - 10 LF 0.5103 Quantity 6 - 10 LM 1.6742
51.1.41a03 Quantity 11 - 15 LF 0.4961 Quantity 11 - 15 LM 1.6276
51.1.41a04 Quantity 16 - 20 LF 0.4820 Quantity 16 - 20 LM 1.5814
51.1.41a05 Quantity 21+ LF 0.4678 Quantity 21+ LM 1.5347
51.1.41b Lap patches 5 to 20 sq ft Lap patches 0.5 to 2.0 sq m51.1.41b01 Quantity 1 - 5 LF 0.3686 Quantity 1 - 5 LM 1.2093
51.1.41b02 Quantity 6 - 10 LF 0.3544 Quantity 6 - 10 LM 1.1627
51.1.41b03 Quantity 11 - 15 LF 0.3402 Quantity 11 - 15 LM 1.1162
51.1.41b04 Quantity 16 - 20 LF 0.3260 Quantity 16 - 20 LM 1.0696
51.1.41b05 Quantity 21+ LF 0.3119 Quantity 21+ LM 1.0233
51.1.41c Lap patches 20 to 40 sq ft Lap patches 2.0 to 4.0 sq m51.1.41c01 Quantity 1 - 5 LF 0.3544 Quantity 1 - 5 LM 1.1627
51.1.41c02 Quantity 6 - 10 LF 0.3402 Quantity 6 - 10 LM 1.1161
51.1.41c03 Quantity 11 - 15 LF 0.3260 Quantity 11 - 15 LM 1.0696
51.1.41c04 Quantity 16 - 20 LF 0.3119 Quantity 16 - 20 LM 1.0232
51.1.41c05 Quantity 21+ LF 0.2977 Quantity 21+ LM 0.9767
51.1.41d Lap patches 40 to 75 sq ft Lap patches 4.0 to 7.0 sq m51.1.41d01 Quantity 1 - 5 LF 0.3402 Quantity 1 - 5 LM 1.1162
51.1.41d02 Quantity 6 - 10 LF 0.3260 Quantity 6 - 10 LM 1.0696
51.1.41d03 Quantity 11 - 15 LF 0.3119 Quantity 11 - 15 LM 1.0233
51.1.41d04 Quantity 16 - 20 LF 0.2977 Quantity 16 - 20 LM 0.9767
51.1.41d05 Quantity 21+ LF 0.2835 Quantity 21+ LM 0.9302
51.1.41e Lap patches greater than 75 sq ft Lap patches greater than 7.0 sq m51.1.41f01 Quantity 1 - 5 LF 0.3260 Quantity 1 - 5 LM 1.0695
51.1.41f02 Quantity 6 - 10 LF 0.3119 Quantity 6 - 10 LM 1.0233
51.1.41f03 Quantity 11 - 15 LF 0.2977 Quantity 11 - 15 LM 0.9767
51.1.41f04 Quantity 16 - 20 LF 0.2835 Quantity 16 - 20 LM 0.9301
51.1.41f05 Quantity 21+ LF 0.2693 Quantity 21+ LM 0.8835
CONE ROOFS & INTERNAL/EXTERNAL FLOATING ROOFS CONE R OOFS & INTERNAL/EXTERNAL FLOATING ROOFS
260
P.2.1.5 Rim Angle & Associated Work 51.1
51.1.5 Rim Angle and Associated Work Rim Angle and Associated Work51.1.51 Rim Angle Removal and Like Replacement. Rim Angle Removal and Like Replacement. 51.1.51 Cone Roof incl prefab (top shell angle) Cone Roof incl prefab (top shell angle)51.1.5101 Angles not exceeding 5.00 lbs/ft. LF 1.0632 Angles not exceeding 8 kg/m LM 3.4880
51.1.5102 Angles over 5.00 not exceeding 10.00 lbs/ft. LF 1.2404 Angles over 8kg/m not exceeding 15 kg./m LM 4.0695
51.1.5103 Angles over 10.00 not exceeding 20.00 lbs/ft. LF 1.4176 Angles over 15kg/m not exceeding 30 kg./m LM 4.6508
51.1.5104 Floating Roof LF 1.0638 Floating Roof LM 3.4901
51.1.52Rim Angle Removal and Vertical Bolting Bar Replacement incl prefab
Rim Angle Removal and Vertical Bolting Bar Replacement incl prefab
51.1.5201 External Floating Roof LF 1.1523 External Floating Roof LM 3.7804
51.1.5202 Internal Floating Roof LF 1.1523 Internal Floating Roof LM 3.7804
51.1.53Rim Vent Nozzle (any nozzle not exceeding 6" in diameter) incl prefab
Rim Vent Nozzle (any nozzle not exceeding 150mm in diameter) incl prefab
51.1.5301 Replace Rim Vent Nozzle. EA 21.2293 Replace Rim Vent Nozzle. EA 21.2293
51.1.5302Remove Rim Vent Nozzle and Lap Patch Hole. Leave existing pipe inside pontoon.
EA 5.6703Remove Rim Vent Nozzle and Lap Patch Hole. Leave existing pipe inside pontoon.
EA 5.6703
51.1.6 Not Used Not Used
CONE ROOFS & INTERNAL/EXTERNAL FLOATING ROOFS CONE R OOFS & INTERNAL/EXTERNAL FLOATING ROOFS
P.2.1.6 Roof Drain Systems 51.1.7 Roof Drain Systems Roof Drain Systems
51.1.73
51.1.73a Single Check Valve Design Single Check Valve Design51.1.73a01 3" Drain Sumps EA 80.0866 80mm Drain Sumps EA 80.0866
51.1.73a02 4" Drain Sumps EA 91.1642 100mm Drain Sumps EA 91.1642
51.1.73a03 5" Drain Sumps EA 95.3919 125mm Drain Sumps EA 95.3919
51.1.73a04 6" Drain Sumps EA 99.6195 150mm Drain Sumps EA 99.6195
51.1.73b Dual Check Valve Design Dual Check Valve Design51.1.73b01 3" Drain Sumps EA 100.0032 80mm Drain Sumps EA 100.0032
51.1.73b02 4" Drain Sumps EA 115.0654 100mm Drain Sumps EA 115.0654
51.1.73b03 5" Drain Sumps EA 119.9692 125mm Drain Sumps EA 119.9692
51.1.73b04 6" Drain Sumps EA 124.8730 150mm Drain Sumps EA 124.8730
Roof Drain Sump. Remove, fabricate and install new roof drain sumps Roof Drain Sump. Remove, fabricate and install new roof drain sumps
261
P.2.1.7 Stilling Wells 51.1
51.1.8 Stilling Wells Stilling Wells51.1.8151.1.8101 8" pipe C.S. LF 2.0874 200mm pipe C.S. LM 6.8484
51.1.8102 10" pipe C.S. LF 2.4392 250mm pipe C.S. LM 8.0025
51.1.8103 20" pipe C.S. LF 3.8967 500mm pipe C.S. LM 12.7843
51.1.8104 8" pipe Galv LF 2.1402 200mm pipe Galv LM 7.0216
51.1.8105 10" pipe Galv LF 2.4989 250mm pipe Galv LM 8.1984
51.1.8106 20" pipe Galv LF 3.9331 500mm pipe Galv LM 12.9037
51.1.8251.1.8201 8" pipe C.S. LF 2.0874 200mm pipe C.S. LM 6.8484
51.1.8202 10" pipe C.S. LF 2.4392 250mm pipe C.S. LM 8.0026
51.1.8203 12" pipe C.S. LF 2.4968 300mm pipe C.S. LM 8.1916
51.1.8204 14" pipe C.S. LF 2.7161 350mm pipe C.S. LM 8.9110
51.1.8205 16" pipe C.S. LF 2.7754 400mm pipe C.S. LM 9.1054
51.1.8206 18" pipe C.S. LF 3.0045 450mm pipe C.S. LM 9.8571
51.1.8207 20" pipe C.S. LF 3.8967 500mm pipe C.S. LM 12.7844
51.1.8208 22" pipe C.S. LF 3.9749 550mm pipe C.S. LM 13.0409
51.1.8209 24" pipe C.S. LF 4.0600 600mm pipe C.S. LM 13.3200
51.1.8210 8" pipe Galv LF 2.1402 200mm pipe Galv LM 7.0216
51.1.8211 10" pipe Galv LF 2.4989 250mm pipe Galv LM 8.1984
51.1.8212 12" pipe Galv LF 2.5803 300mm pipe Galv LM 8.4654
51.1.8213 14" pipe Galv LF 2.8085 350mm pipe Galv LM 9.2141
51.1.8214 16" pipe Galv LF 2.8827 400mm pipe Galv LM 9.4576
51.1.8215 18" pipe Galv LF 3.1227 450mm pipe Galv LM 10.2450
51.1.8216 20" pipe Galv LF 4.0248 500mm pipe Galv LM 13.2046
51.1.8217 22" pipe Galv LF 4.1148 550mm pipe Galv LM 13.4998
51.1.8218 24" pipe Galv LF 4.2106 600mm pipe Galv LM 13.8141
Replace cone roof stilling well (Fabricate and install)Replace cone roof stilling well (Fabricate and install)
Replace floating roof stilling well (Fabricate and install) Replace floating roof stilling well (Fabricate and install)
CONE ROOFS & INTERNAL/EXTERNAL FLOATING ROOFS CONE R OOFS & INTERNAL/EXTERNAL FLOATING ROOFS
262
51.1.83 Replace Guide Pole (Fabricate and install) Replace Guide Pole (Fabricate and install)51.1.8301 6" pipe C.S. LF 1.8568 150mm pipe C.S. LM 6.0917
51.1.8302 8" pipe C.S. LF 1.9176 200mm pipe C.S. LM 6.2913
51.1.8303 10" pipe C.S. LF 2.2695 250mm pipe C.S. LM 7.4458
51.1.8304 12" pipe C.S. LF 3.7270 300mm pipe C.S. LM 12.2276
51.1.8305 6" pipe Galv LF 1.8992 150mm pipe Galv LM 6.2309
51.1.8306 8" pipe Galv LF 1.9704 200mm pipe Galv LM 6.4645
51.1.8307 10" pipe Galv LF 2.3292 250mm pipe Galv LM 7.6416
51.1.8308 12" pipe Galv LF 3.8551 300mm pipe Galv LM 12.6478
51.1.8451.1.8401 6" pipe EA 21.9690 150mm pipe EA 21.9690
51.1.8402 8" pipe EA 22.1719 200mm pipe EA 22.1719
51.1.8403 10" pipe EA 22.1719 250mm pipe EA 22.1719
51.1.8404 12" Pipe EA 22.3748 300mm Pipe EA 22.3748
Fabricate and install Guide Pole Assembly. Replace rollers and bearing Fabricate and install Guide Pol e Assembly. Replace rollers and bearing
P.2.1.8 Roof Support Legs 51.1.9 Roof Support Legs Roof Support Legs51.1.9151.1.91b Lower roof support legs with tank in service. EA 0.4253 Lower roof support legs with tank in service. EA 0.4253
51.1.91d Raise roof support legs with tank in service. EA 0.4253 Raise roof support legs with tank in service. EA 0.4253
51.1.92 Roof support leg pins Roof support leg pins51.1.92a Replace roof support leg pins and install cotter pins EA 0.4312 Replace roof support leg pins and install cotter pins EA 0.4312
Floating roof tank roof support legs Lower roof sup port legs with tank in Floating roof tank roof supp ort legs Lower roof support legs with tank in
263
P.2.2 Shell Work
P.2.2.1 Shell insert plates / doorsheets 51.2 SHELL WORK SHELL WORK
51.2.1 Shell Insert Plates / Doorsheets Shell Insert Plates / Doorsheets
51.2.11
51.2.11a Inserts 20 sq ft or less Inserts 2.0 sq m or less51.2.11a01 1/4" C.S. plate LF 3.2674 6mm C.S. plate LM 10.7196
51.2.11a02 5/16" C.S. plate LF 3.5529 8mm C.S. plate LM 11.6560
51.2.11a03 3/8" C.S. plate LF 3.8384 10mm C.S. plate LM 12.5931
51.2.11a04 1/2" C.S. plate LF 4.2675 12mm C.S. plate LM 14.0008
51.2.11a05 9/16" C.S. plate LF 4.4828 14mm C.S. plate LM 14.7071
51.2.11a06 5/8" C.S. plate LF 4.6981 16mm C.S. plate LM 15.4136
51.2.11a07 3/4" C.S. plate LF 5.2692 19mm C.S. plate LM 17.2871
51.2.11a08 7/8" C.S. plate LF 5.7129 22mm C.S. plate LM 18.7427
51.2.11a09 1" C.S. plate LF 6.1565 25mm C.S. plate LM 20.1982
51.2.11a10 1-1/8" C.S. plate LF 6.7276 28mm C.S. plate LM 22.0720
51.2.11a11 1-1/4" C.S. plate LF 7.5823 32mm C.S. plate LM 24.8760
51.2.11a12 1-3/8" C.S. plate LF 8.0259 35mm C.S. plate LM 26.3311
51.2.11a13 1-1/2" C.S. plate LF 8.4694 38mm C.S. plate LM 27.7865
51.2.11b Inserts 20 to 40 sq ft Inserts 2.0 to 4.0 sq m51.2.11b01 1/4" C.S. plate LF 3.0762 6mm C.S. plate LM 10.0924
51.2.11b02 5/16" C.S. plate LF 3.2554 8mm C.S. plate LM 10.2987
51.2.11b03 3/8" C.S. plate LF 3.4345 10mm C.S. plate LM 11.2678
51.2.11b04 1/2" C.S. plate LF 3.7927 12mm C.S. plate LM 12.4430
51.2.11b05 9/16" C.S. plate LF 4.0110 14mm C.S. plate LM 13.1593
51.2.11b06 5/8" C.S. plate LF 4.2293 16mm C.S. plate LM 13.8755
51.2.11b07 3/4" C.S. plate LF 4.6527 19mm C.S. plate LM 15.2646
51.2.11b08 7/8" C.S. plate LF 5.1291 22mm C.S. plate LM 16.8274
51.2.11b09 1" C.S. plate LF 5.6054 25mm C.S. plate LM 18.3902
51.2.11b10 1-1/8" C.S. plate LF 6.2475 28mm C.S. plate LM 20.4968
51.2.11b11 1-1/4" C.S. plate LF 6.9604 32mm C.S. plate LM 22.8356
51.2.11b12 1-3/8" C.S. plate LF 7.3287 35mm C.S. plate LM 24.0438
51.2.11b13 1-1/2" C.S. plate LF 7.6969 38mm C.S. plate LM 25.2520
Remove existing and install new or reconditioned sh ell insert plate, with or without nozzles
Remove existing and install new or reconditioned sh ell insert plate, with or without nozzles
264
51.2.11c Inserts 40 to 75 sq ft Inserts 4.0 to 7.0 sq m51.2.11c01 1/4" C.S. plate LF 2.3045 6mm C.S. plate LM 7.5606
51.2.11c02 5/16" C.S. plate LF 2.4483 8mm C.S. plate LM 7.7455
51.2.11c03 3/8" C.S. plate LF 2.5920 10mm C.S. plate LM 8.5037
51.2.11c04 1/2" C.S. plate LF 3.0211 12mm C.S. plate LM 9.9116
51.2.11c05 9/16" C.S. plate LF 3.1655 14mm C.S. plate LM 10.3853
51.2.11c06 5/8" C.S. plate LF 3.3099 16mm C.S. plate LM 10.8591
51.2.11c07 3/4" C.S. plate LF 3.7393 19mm C.S. plate LM 12.2679
51.2.11c08 7/8" C.S. plate LF 4.1065 22mm C.S. plate LM 13.4727
51.2.11c09 1" C.S. plate LF 4.4737 25mm C.S. plate LM 14.6773
51.2.11c10 1-1/8" C.S. plate LF 5.1866 28mm C.S. plate LM 17.0161
51.2.11c11 1-1/4" C.S. plate LF 5.8996 32mm C.S. plate LM 19.3554
51.2.11c12 1-3/8" C.S. plate LF 6.2616 35mm C.S. plate LM 20.5429
51.2.11c13 1-1/2" C.S. plate LF 6.6235 38mm C.S. plate LM 21.7304
51.2.11d Inserts greater than 75 sq ft Inserts greater than 7.0 sq m51.2.11d01 1/4" C.S. plate LF 2.3407 6mm C.S. plate LM 7.6793
51.2.11d02 5/16" C.S. plate LF 2.4135 8mm C.S. plate LM 7.6353
51.2.11d03 3/8" C.S. plate LF 2.4863 10mm C.S. plate LM 8.1570
51.2.11d04 1/2" C.S. plate LF 2.9155 12mm C.S. plate LM 9.5652
51.2.11d05 9/16" C.S. plate LF 3.0599 14mm C.S. plate LM 10.0389
51.2.11d06 5/8" C.S. plate LF 3.2043 16mm C.S. plate LM 10.5127
51.2.11d07 3/4" C.S. plate LF 3.6337 19mm C.S. plate LM 11.9214
51.2.11d08 7/8" C.S. plate LF 3.9991 22mm C.S. plate LM 13.1201
51.2.11d09 1" C.S. plate LF 4.3644 25mm C.S. plate LM 14.3188
51.2.11d10 1-1/8" C.S. plate LF 5.0773 28mm C.S. plate LM 16.6575
51.2.11d11 1-1/4" C.S. plate LF 5.7903 32mm C.S. plate LM 18.9968
51.2.11d12 1-3/8" C.S. plate LF 6.1945 35mm C.S. plate LM 20.3227
51.2.11d13 1-1/2" C.S. plate LF 6.5986 38mm C.S. plate LM 21.6486
51.2.12
51.2.12a To suit shell insert 1/4" to 1/2" thick LF 0.3544 To suit shell insert 6mm to 12mm thick LM 1.1628
51.2.12b To suit shell insert over 1/2" but not exceeding 1" thick. LF 0.3544 To suit shell insert over 12mm but not exceeding 25mm thick. LM 1.1627
51.2.12c To suit shell insert over 1" but not exceeding 1 1/2" thick. LF 0.3544 To suit shell insert over 25mm but not exceeding 38mm thick. LM 1.1628
51.2.14 Buttering Shell Inserts (if required) Buttering Shell Inserts (if required)51.2.14a 1/2" to 3/4" thickness LF 0.7088 12mm to 20mm thickness LM 2.3255
51.2.14b 3/4" to 1-1/4" thickness LF 0.9214 20mm to 30mm thickness LM 3.0229
51.2.14c > 1-1/4" thickness LF 1.0632 >30mm thickness LM 3.4881
Extra over shell insert plates for corner welding b etween shell insert plate and tank bottom plate. Corner weld to be in accorda nce with specific Site Specifications (Note corner welds associated with b ottom replacement are to be included with the approp
Extra over shell insert plates for corner welding b etween shell insert plate and tank bottom plate. Corner weld to be in accorda nce with specific Site Specifications (Note corner welds associated with b ottom replacement are to be included with the approp
265
P.2.2.2 Lap Patches (Overplate) 51.2 SHELL WORK SHELL WORK
51.2.2 Lap Patches (Overplate) Lap Patches (Overplate)
51.2.21
51.2.21a Lap patches 5 sq ft or less Lap patches 0.5 sq m or less51.2.21a01 1/4" C.S. plate LF 0.7939 6mm C.S. plate LM 2.6046
51.2.21a02 5/16" C.S. plate LF 0.8490 8mm C.S. plate LM 2.6315
51.2.21a03 3/8" C.S. plate LF 0.9040 10mm C.S. plate LM 2.9659
51.2.21a04 1/2" C.S. plate LF 1.0496 12mm C.S. plate LM 3.4435
51.2.21b Lap patches 6 to 24 sq ft Lap patches 0.5 to 2.0 sq m51.2.21b01 1/4" C.S. plate LF 0.6521 6mm C.S. plate LM 2.1394
51.2.21b02 5/16" C.S. plate LF 0.7072 8mm C.S. plate LM 2.1936
51.2.21b03 3/8" C.S. plate LF 0.7622 10mm C.S. plate LM 2.5006
51.2.21b04 1/2" C.S. plate LF 0.9078 12mm C.S. plate LM 2.9784
Lap Patch Shell plate - Based on 1 to 5 patches (al l sizes combined) Lap Patch Shell plate - Based on 1 to 5 patches (all sizes combined)
266
P.2.2.3 Manways & nozzles 51.2 SHELL WORK SHELL WORK
51.2.3 Manways and Nozzles Manways and Nozzles
51.2.31
51.2.31a 24" manway 600mm manway51.2.31a01 thickness less than 3/4" EA 94.5311 thickness less than 19mm EA 94.5311
51.2.31a02 thickness 3/4" - 1" EA 100.0122 thickness 19mm - 25mm EA 100.0122
51.2.31a03 thickness 1" - 1-1/2" EA 115.8392 thickness 25mm - 38mm EA 115.8392
51.2.31b 30" manway 750mm manway51.2.31b01 thickness less than 3/4" EA 105.5085 thickness less than 19mm EA 105.5085
51.2.31b02 thickness 3/4" - 1" EA 116.2780 thickness 19mm - 25mm EA 116.2780
51.2.31b03 thickness 1" - 1-1/2" EA 127.2935 thickness 25mm - 38mm EA 127.2935
51.2.31c 36" manway 900mm manway 51.2.31c01 thickness less than 3/4" EA 124.1885 thickness less than 19mm EA 124.1885
51.2.31c02 thickness 3/4" - 1" EA 132.9360 thickness 19mm - 25mm EA 132.9360
51.2.31c03 thickness 1" - 1-1/2" EA 149.0952 thickness 25mm - 38mm EA 149.0952
51.2.32Fabricate and install shell manway in shell plate in the field in accordance with specifications referenced in Section 4. (Includes reinforcement and testing.)
Fabricate and install shell manway in shell plate i n the field in accordance with specifications referenced in Section 4. (Includes reinforcement an d testing.)
51.2.32a 24" manway 600mm manway51.2.32a01 thickness less than 3/4" EA 69.0991 thickness less than 19mm EA 69.0991
51.2.32a02 thickness 3/4" - 1" EA 77.0792 thickness 19mm - 25mm EA 77.0792
51.2.32a03 thickness 1" - 1-1/2" EA 90.8920 thickness 25mm - 38mm EA 90.8920
51.2.32b 30" manway 750mm manway51.2.32b01 thickness less than 3/4" EA 72.8193 thickness less than 19mm EA 72.8193
51.2.32b02 thickness 3/4" - 1" EA 81.8771 thickness 19mm - 25mm EA 81.8771
51.2.32b03 thickness 1" - 1-1/2" EA 95.1851 thickness 25mm - 38mm EA 95.1851
51.2.32c 36" manway 900mm manway 51.2.32c01 thickness less than 3/4" EA 80.5845 thickness less than 19mm EA 80.5845
51.2.32c02 thickness 3/4" - 1" EA 90.1851 thickness 19mm - 25mm EA 90.1851
51.2.32c03 thickness 1" - 1-1/2" EA 104.3275 thickness 25mm - 38mm EA 104.3275
Pre-Fabricate shell manway and shell plate in accordance with specifications referenced in Section 4. (Includes reinforcement and testing.)
Pre-Fabricate shell manway and shell plate in accordance with specifications referenced in Section 4. (Includes reinforcement and testing.)
267
51.2.33Double plate existing manways (Prefab, Field Fit-up and install)
Double plate existing manways (Prefab, Field Fit-up and install)
51.2.33a 24" manway 600mm manway51.2.33a01 thickness less than 3/4" EA 29.0013 thickness less than 19mm EA 29.0013
51.2.33a02 thickness 3/4" to 1" EA 32.3863 thickness 19mm to 25mm EA 32.3863
51.2.33a03 thickness 1" to 1-1/2" EA 36.0528 thickness 25mm to 38mm EA 36.0528
51.2.33b 30" manway 750mm manway51.2.33b01 thickness less than 3/4" EA 33.2540 thickness less than 19mm EA 33.2540
51.2.33b02 thickness 3/4" to 1" EA 36.6390 thickness 19mm to 25mm EA 36.6390
51.2.33b03 thickness 1" to 1-1/2" EA 40.3055 thickness 25mm to 38mm EA 40.3055
51.2.33c 36" manway 900mm manway 51.2.33c01 thickness less than 3/4" EA 35.9040 thickness less than 19mm EA 35.9040
51.2.33c02 thickness 3/4" to 1" EA 40.0499 thickness 19mm to 25mm EA 40.0499
51.2.33c03 thickness 1" to 1-1/2" EA 43.9675 thickness 25mm to 38mm EA 43.9675
268
51.2.34
51.2.34a 2" Carbon Steel nozzle 50mm Carbon Steel nozzle51.2.34a01 thickness less than 3/4" EA 8.5737 thickness less than 19mm EA 8.5737
51.2.34a02 thickness 3/4" to 1" EA 9.8979 thickness 19mm to 25mm EA 9.8979
51.2.34a03 thickness 1" to 1-1/2" EA 11.3240 thickness 25mm to 38mm EA 11.3240
51.2.34b 3" Carbon Steel nozzle 80mm Carbon Steel nozzle51.2.34b01 thickness less than 3/4" EA 14.3109 thickness less than 19mm EA 14.3109
51.2.34b02 thickness 3/4" to 1" EA 15.3422 thickness 19mm to 25mm EA 15.3422
51.2.34b03 thickness 1" to 1-1/2" EA 16.5747 thickness 25mm to 38mm EA 16.5747
51.2.34c 4" Carbon Steel nozzle 100mm Carbon Steel nozzle51.2.34c01 thickness less than 3/4" EA 16.9897 thickness less than 19mm EA 16.9897
51.2.34c02 thickness 3/4" to 1" EA 18.2278 thickness 19mm to 25mm EA 18.2278
51.2.34c03 thickness 1" to 1-1/2" EA 19.8748 thickness 25mm to 38mm EA 19.8748
51.2.34d 6" Carbon Steel nozzle 150mm Carbon Steel nozzle51.2.34d01 thickness less than 3/4" EA 19.3372 thickness less than 19mm EA 19.3372
51.2.34d02 thickness 3/4" to 1" EA 20.5925 thickness 19mm to 25mm EA 20.5925
51.2.34d03 thickness 1" to 1-1/2" EA 22.2502 thickness 25mm to 38mm EA 22.2502
51.2.34e 8" Carbon Steel nozzle 200mm Carbon Steel nozzle51.2.34 e01 thickness less than 3/4" EA 23.6226 thickness less than 19mm EA 23.6226
51.2.34 e02 thickness 3/4" to 1" EA 25.9933 thickness 19mm to 25mm EA 25.9933
51.2.34 e03 thickness 1" to 1-1/2" EA 29.0897 thickness 25mm to 38mm EA 29.0897
51.2.34f 10" Carbon Steel nozzle 250mm Carbon Steel nozzle51.2.34f01 thickness less than 3/4" EA 28.1062 thickness less than 19mm EA 28.1062
51.2.34f02 thickness 3/4" to 1" EA 31.1160 thickness 19mm to 25mm EA 31.1160
51.2.34f03 thickness 1" to 1-1/2" EA 34.5357 thickness 25mm to 38mm EA 34.5357
51.2.34g 12" Carbon Steel nozzle 300mm Carbon Steel nozzle51.2.34g01 thickness less than 3/4" EA 30.4359 thickness less than 19mm EA 30.4359
51.2.34g02 thickness 3/4" to 1" EA 34.1638 thickness 19mm to 25mm EA 34.1638
51.2.34g03 thickness 1" to 1-1/2" EA 38.3985 thickness 25mm to 38mm EA 38.3985
51.2.34h 14" Carbon Steel nozzle 350mm Carbon Steel nozzle51.2.34h01 thickness less than 3/4" EA 32.5463 thickness less than 19mm EA 32.5463
51.2.34h02 thickness 3/4" to 1" EA 36.7044 thickness 19mm to 25mm EA 36.7044
51.2.34h03 thickness 1" to 1-1/2" EA 42.4949 thickness 25mm to 38mm EA 42.4949
51.2.34i 16" Carbon Steel nozzle 400mm Carbon Steel nozzle51.2.34i01 thickness less than 3/4" EA 36.7598 thickness less than 19mm EA 36.7598
51.2.34i02 thickness 3/4" to 1" EA 42.5731 thickness 19mm to 25mm EA 42.5731
51.2.34i03 thickness 1" to 1-1/2" EA 49.1988 thickness 25mm to 38mm EA 49.1988
51.2.34j 18" Carbon Steel nozzle 450mm Carbon Steel nozzle51.2.34j01 thickness less than 3/4" EA 39.3229 thickness less than 19mm EA 39.3229
51.2.34j02 thickness 3/4" to 1" EA 46.2896 thickness 19mm to 25mm EA 46.2896
51.2.34j03 thickness 1" to 1-1/2" EA 53.3557 thickness 25mm to 38mm EA 53.3557
51.2.34k 20" Carbon Steel nozzle 500mm Carbon Steel nozzle51.2.34k01 thickness less than 3/4" EA 44.3027 thickness less than 19mm EA 44.3027
51.2.34k02 thickness 3/4" to 1" EA 51.7990 thickness 19mm to 25mm EA 51.7990
51.2.34k03 thickness 1" to 1-1/2" EA 60.1154 thickness 25mm to 38mm EA 60.1154
51.2.34l 24" Carbon Steel nozzle 600mm Carbon Steel nozzle51.2.34l01 thickness less than 3/4" EA 47.6350 thickness less than 19mm EA 47.6350
51.2.34l02 thickness 3/4" to 1" EA 55.0755 thickness 19mm to 25mm EA 55.0755
51.2.34l03 thickness 1" to 1-1/2" EA 63.4469 thickness 25mm to 38mm EA 63.4469
51.2.34m 30" Carbon Steel nozzle 750mm Carbon Steel nozzle51.2.34m01 thickness less than 3/4" EA 53.5893 thickness less than 19mm EA 53.5893
51.2.34m02 thickness 3/4" to 1" EA 61.7885 thickness 19mm to 25mm EA 61.7885
51.2.34m03 thickness 1" to 1-1/2" EA 71.9840 thickness 25mm to 38mm EA 71.9840
51.2.34n 36" Carbon Steel nozzle 900mm Carbon Steel nozzle51.2.34n01 thickness less than 3/4" EA 60.5560 thickness less than 19mm EA 60.5560
51.2.34n02 thickness 3/4" to 1" EA 70.1240 thickness 19mm to 25mm EA 70.1240
51.2.34n03 thickness 1" to 1-1/2" EA 81.6240 thickness 25mm to 38mm EA 81.6240
51.2.34p 40" Carbon Steel nozzle 1000mm Carbon Steel nozzle51.2.34p01 thickness less than 3/4" EA 65.4010 thickness less than 19mm EA 65.4010
51.2.34p02 thickness 3/4" to 1" EA 75.3400 thickness 19mm to 25mm EA 75.3400
51.2.34p03 thickness 1" to 1-1/2" EA 87.8480 thickness 25mm to 38mm EA 87.8480
Pre-Fabricate shell nozzles and shell plate in accordance with specifications referenced in Section 4.
Pre-Fabricate shell nozzles and shell plate in accordance with specifications referenced in Section 4.
269
51.2.35
51.2.35a 2" Carbon Steel nozzle 50mm Carbon Steel nozzle51.2.35a01 thickness less than 3/4" EA 8.2663 thickness less than 19mm EA 8.2663
51.2.35a02 thickness 3/4" to 1" EA 11.8102 thickness 19mm to 25mm EA 11.8102
51.2.35a03 thickness 1" to 1-1/2" EA 13.2278 thickness 25mm to 38mm EA 13.2278
51.2.35b 3" Carbon Steel nozzle 80mm Carbon Steel nozzle51.2.35b01 thickness less than 3/4" EA 9.5144 thickness less than 19mm EA 9.5144
51.2.35b02 thickness 3/4" to 1" EA 15.2916 thickness 19mm to 25mm EA 15.2916
51.2.35b03 thickness 1" to 1-1/2" EA 18.2362 thickness 25mm to 38mm EA 18.2362
51.2.35c 4" Carbon Steel nozzle 100mm Carbon Steel nozzle51.2.35c01 thickness less than 3/4" EA 10.9641 thickness less than 19mm EA 10.9641
51.2.35c02 thickness 3/4" to 1" EA 17.5595 thickness 19mm to 25mm EA 17.5595
51.2.35c03 thickness 1" to 1-1/2" EA 20.6111 thickness 25mm to 38mm EA 20.6111
51.2.35d 6" Carbon Steel nozzle 150mm Carbon Steel nozzle51.2.35d01 thickness less than 3/4" EA 12.3550 thickness less than 19mm EA 12.3550
51.2.35d02 thickness 3/4" to 1" EA 18.9632 thickness 19mm to 25mm EA 18.9632
51.2.35d03 thickness 1" to 1-1/2" EA 22.0274 thickness 25mm to 38mm EA 22.0274
51.2.35e 8" Carbon Steel nozzle 200mm Carbon Steel nozzle51.2.35e01 thickness less than 3/4" EA 15.7832 thickness less than 19mm EA 15.7832
51.2.35e02 thickness 3/4" to 1" EA 20.2700 thickness 19mm to 25mm EA 20.2700
51.2.35e03 thickness 1" to 1-1/2" EA 23.3419 thickness 25mm to 38mm EA 23.3419
51.2.35f 10" Carbon Steel nozzle 250mm Carbon Steel nozzle51.2.35f01 thickness less than 3/4" EA 20.8681 thickness less than 19mm EA 20.8681
51.2.35f02 thickness 3/4" to 1" EA 25.3727 thickness 19mm to 25mm EA 25.3727
51.2.35f03 thickness 1" to 1-1/2" EA 29.8748 thickness 25mm to 38mm EA 29.8748
51.2.35g 12" Carbon Steel nozzle 300mm Carbon Steel nozzle51.2.35g01 thickness less than 3/4" EA 23.2122 thickness less than 19mm EA 23.2122
51.2.35g02 thickness 3/4" to 1" EA 27.7346 thickness 19mm to 25mm EA 27.7346
51.2.35g03 thickness 1" to 1-1/2" EA 32.2569 thickness 25mm to 38mm EA 32.2569
51.2.35h 14" Carbon Steel nozzle 350mm Carbon Steel nozzle51.2.35h01 thickness less than 3/4" EA 26.8060 thickness less than 19mm EA 26.8060
51.2.35h02 thickness 3/4" to 1" EA 29.9721 thickness 19mm to 25mm EA 29.9721
51.2.35h03 thickness 1" to 1-1/2" EA 37.3909 thickness 25mm to 38mm EA 37.3909
51.2.35i 16" Carbon Steel nozzle 400mm Carbon Steel nozzle51.2.35i01 thickness less than 3/4" EA 29.3352 thickness less than 19mm EA 29.3352
51.2.35i02 thickness 3/4" to 1" EA 32.5748 thickness 19mm to 25mm EA 32.5748
51.2.35i03 thickness 1" to 1-1/2" EA 40.0697 thickness 25mm to 38mm EA 40.0697
51.2.3j 18" Carbon Steel nozzle 450mm Carbon Steel nozzle51.2.35j01 thickness less than 3/4" EA 34.81.92 thickness less than 19mm EA 34.81.92
51.2.35j02 thickness 3/4" to 1" EA 36.7710 thickness 19mm to 25mm EA 36.7710
51.2.35j03 thickness 1" to 1-1/2" EA 42.9755 thickness 25mm to 38mm EA 42.9755
51.2.35k 20" Carbon Steel nozzle 500mm Carbon Steel nozzle51.2.35k01 thickness less than 3/4" EA 40.3648 thickness less than 19mm EA 40.3648
51.2.35k02 thickness 3/4" to 1" EA 43.7621 thickness 19mm to 25mm EA 43.7621
51.2.35k03 thickness 1" to 1-1/2" EA 48.5744 thickness 25mm to 38mm EA 48.5744
51.2.35l 24" Carbon Steel nozzle 600mm Carbon Steel nozzle51.2.35l01 thickness less than 3/4" EA 42.8750 thickness less than 19mm EA 42.8750
51.2.35l02 thickness 3/4" to 1" EA 46.2105 thickness 19mm to 25mm EA 46.2105
51.2.35l03 thickness 1" to 1-1/2" EA 57.8812 thickness 25mm to 38mm EA 57.8812
51.2.35m 30" Carbon Steel nozzle 750mm Carbon Steel nozzle51.2.35m01 thickness less than 3/4" EA 48.2335 thickness less than 19mm EA 48.2335
51.2.35m02 thickness 3/4" to 1" EA 51.3705 thickness 19mm to 25mm EA 51.3705
51.2.35m03 thickness 1" to 1-1/2" EA 62.7100 thickness 25mm to 38mm EA 62.7100
51.2.35n 36" Carbon Steel nozzle 900mm Carbon Steel nozzle51.2.35n01 thickness less than 3/4" EA 54.4821 thickness less than 19mm EA 54.4821
51.2.35n02 thickness 3/4" to 1" EA 58.0779 thickness 19mm to 25mm EA 58.0779
51.2.35n03 thickness 1" to 1-1/2" EA 65.0975 thickness 25mm to 38mm EA 65.0975
51.2.35p 40" Carbon Steel nozzle 1000mm Carbon Steel nozzle51.2.35p01 thickness less than 3/4" EA 60.4183 thickness less than 19mm EA 60.4183
51.2.35p02 thickness 3/4" to 1" EA 63.7574 thickness 19mm to 25mm EA 63.7574
51.2.35p03 thickness 1" to 1-1/2" EA 72.5021 thickness 25mm to 38mm EA 72.5021
Fabricate and install shell nozzles in shell plate in the field as per API 650, 653 (Includes reinforcement and testing.)
Fabricate and install shell nozzles in shell plate in the field as per API 650, 653 (Includes reinforcement and testing.)
270
51.2.3651.2.36c 4" Carbon Steel nozzle 100mm Carbon Steel nozzle51.2.36c01 thickness less than 3/4" EA 8.1266 thickness less than 19mm EA 8.1266
51.2.36c02 thickness 3/4" to 1" EA 11.0824 thickness 19mm to 25mm EA 11.0824
51.2.36c03 thickness 1" to 1-1/2" EA 14.0333 thickness 25mm to 38mm EA 14.0333
51.2.36d 6" Carbon Steel nozzle 150mm Carbon Steel nozzle51.2.36d01 thickness less than 3/4" EA 10.1716 thickness less than 19mm EA 10.1716
51.2.36d02 thickness 3/4" to 1" EA 13.1507 thickness 19mm to 25mm EA 13.1507
51.2.36d03 thickness 1" to 1-1/2" EA 16.1157 thickness 25mm to 38mm EA 16.1157
51.2.36e 8" Carbon Steel nozzle 200mm Carbon Steel nozzle51.2.36e01 thickness less than 3/4" EA 11.9991 thickness less than 19mm EA 11.9991
51.2.36e02 thickness 3/4" to 1" EA 14.9818 thickness 19mm to 25mm EA 14.9818
51.2.36e03 thickness 1" to 1-1/2" EA 17.9518 thickness 25mm to 38mm EA 17.9518
51.2.36f 10" Carbon Steel nozzle 250mm Carbon Steel nozzle51.2.36f01 thickness less than 3/4" EA 14.1475 thickness less than 19mm EA 14.1475
51.2.36f02 thickness 3/4" to 1" EA 17.1580 thickness 19mm to 25mm EA 17.1580
51.2.36f03 thickness 1" to 1-1/2" EA 20.2476 thickness 25mm to 38mm EA 20.2476
51.2.36g 12" Carbon Steel nozzle 300mm Carbon Steel nozzle51.2.36g01 thickness less than 3/4" EA 16.0896 thickness less than 19mm EA 16.0896
51.2.36g02 thickness 3/4" to 1" EA 19.2248 thickness 19mm to 25mm EA 19.2248
51.2.36g03 thickness 1" to 1-1/2" EA 22.3296 thickness 25mm to 38mm EA 22.3296
51.2.36h 14" Carbon Steel nozzle 350mm Carbon Steel nozzle51.2.36h01 thickness less than 3/4" EA 17.9273 thickness less than 19mm EA 17.9273
51.2.36h02 thickness 3/4" to 1" EA 21.0790 thickness 19mm to 25mm EA 21.0790
51.2.36h03 thickness 1" to 1-1/2" EA 24.2003 thickness 25mm to 38mm EA 24.2003
51.2.36i 16" Carbon Steel nozzle 400mm Carbon Steel nozzle51.2.36i01 thickness less than 3/4" EA 19.5663 thickness less than 19mm EA 19.5663
51.2.36i02 thickness 3/4" to 1" EA 22.7472 thickness 19mm to 25mm EA 22.7472
51.2.36i03 thickness 1" to 1-1/2" EA 25.8875 thickness 25mm to 38mm EA 25.8875
51.2.36j 18" Carbon Steel nozzle 450mm Carbon Steel nozzle51.2.36j01 thickness less than 3/4" EA 22.6420 thickness less than 19mm EA 22.6420
51.2.36j02 thickness 3/4" to 1" EA 25.8799 thickness 19mm to 25mm EA 25.8799
51.2.36j03 thickness 1" to 1-1/2" EA 29.0608 thickness 25mm to 38mm EA 29.0608
51.2.36k 20" Carbon Steel nozzle 500mm Carbon Steel nozzle51.2.36k01 thickness less than 3/4" EA 25.6973 thickness less than 19mm EA 25.6973
51.2.36k02 thickness 3/4" to 1" EA 28.9594 thickness 19mm to 25mm EA 28.9594
51.2.36k03 thickness 1" to 1-1/2" EA 32.1580 thickness 25mm to 38mm EA 32.1580
51.2.36l 24" Carbon Steel nozzle 600mm Carbon Steel nozzle51.2.36l01 thickness less than 3/4" EA 28.5236 thickness less than 19mm EA 28.5236
51.2.36l02 thickness 3/4" to 1" EA 31.2330 thickness 19mm to 25mm EA 31.2330
51.2.36l03 thickness 1" to 1-1/2" EA 34.4190 thickness 25mm to 38mm EA 34.4190
51.2.36m 30" Carbon Steel nozzle 750mm Carbon Steel nozzle51.2.36m01 thickness less than 3/4" EA 32.5100 thickness less than 19mm EA 32.5100
51.2.36m02 thickness 3/4" to 1" EA 35.3870 thickness 19mm to 25mm EA 35.3870
51.2.36m03 thickness 1" to 1-1/2" EA 38.9220 thickness 25mm to 38mm EA 38.9220
51.2.36n 36" Carbon Steel nozzle 900mm Carbon Steel nozzle51.2.36n01 thickness less than 3/4" EA 37.6465 thickness less than 19mm EA 37.6465
51.2.36n02 thickness 3/4" to 1" EA 42.1600 thickness 19mm to 25mm EA 42.1600
51.2.36n03 thickness 1" to 1-1/2" EA 48.2778 thickness 25mm to 38mm EA 48.2778
51.2.36p 40" Carbon Steel nozzle 1000mm Carbon Steel nozzle51.2.36p01 thickness less than 3/4" EA 43.7450 thickness less than 19mm EA 43.7450
51.2.36p02 thickness 3/4" to 1" EA 49.4300 thickness 19mm to 25mm EA 49.4300
51.2.36p03 thickness 1" to 1-1/2" EA 54.8690 thickness 25mm to 38mm EA 54.8690
51.2.37 Remove or reinstall shell manway cover. Remove or reinstall shell manway cover. 51.2.37a 18" manway EA 7.0879 450mm manway EA 7.0879
51.2.37b 24"manway EA 7.7966 600mm manway EA 7.7966
51.2.37c 30" manway EA 8.5054 750mm manway EA 8.5054
51.2.37d 36" manway EA 9.9230 900mm manway EA 9.9230
Double plate existing nozzles (Prefab, Field Fit-up and install) Double plate existing nozzles (Prefab, Field Fit-up and install)
271
P.2.2.4 Insulation stops & shields 51.2 SHELL WORK SHELL WORK
51.2.4 Insulation Stops and Shields Insulation Stops and Shields
51.2.41
51.2.4101Insulation Stop, toe out. Angle to be stitch weld 2" on 12" both top & bottom where angle fits against tank shell.
LF 0.2126Insulation Stop, toe out. Angle to be stitch weld 50mm on 300mm both top & bottom where angle fits against tank shell.
LM 0.6975
51.2.4102Insulation Rain Shield, toe in. Angle to be 100% seal welded where angle fits against tank shell.
LF 0.4253Insulation Rain Shield, toe in. Angle to be 100% seal welded where angle fits against tank shell.
LM 1.3954
Fabricate and install 1/4" x 3" x 3" C.S. angle rol led to the radius of the tank for insulation stops and shields
Fabricate and install 6mm x 80mm x 80mm C.S. angle rolled to the radius of the tank for insulation stops and shields
P.2.2.5 Couplings & valves 51.2.5 Shell Couplings and valves Shell Couplings and valves
51.2.51
51.2.51a 2" couplings EA 2.1264 50mm couplings EA 2.1264
51.2.51b 1-1/2" couplings EA 1.9137 40mm couplings EA 1.9137
51.2.51c 1" couplings EA 1.7011 25mm couplings EA 1.7011
51.2.51d 3/4" couplings EA 1.5593 20mm couplings EA 1.5593
51.2.51e 1/2" couplings EA 1.4176 12mm couplings EA 1.4176
51.2.52 Not Used Not Used
Install 6,000 lb. couplings into tank shell in accordance with specifications referenced in Section 4.
Install 2720 KG couplings into tank shell in accordance with specifications referenced in Section 4.
272
P.2.3 Bottom Work
P.2.3.1 Demolition & Removal Work 51.3 BOTTOM WORK BOTTOM WORK
51.3.1 Demolition and Removal Work. Demolition and Removal Work.
51.3.11
51.3.11a 1/4" C.S. plate SF 0.0992 6mm C.S. plate SM 1.0676
51.3.11b 5/16" C.S. plate SF 0.1205 8mm C.S. plate SM 1.2214
51.3.11c 3/8" C.S. plate SF 0.1418 10mm C.S. plate SM 1.5261
51.3.11d 1/2" C.S. plate SF 0.2835 12mm C.S. plate SM 3.0517
51.3.12
51.3.12a 1/4" C.S. plate SF 0.0921 6mm C.S. plate SM 0.9913
51.3.12b 5/16" C.S. plate SF 0.1170 8mm C.S. plate SM 1.1838
51.3.12c 3/8" C.S. plate SF 0.1418 10mm C.S. plate SM 1.5262
51.3.12d 1/2" C.S. plate SF 0.2835 12mm C.S. plate SM 3.0513
51.3.13
51.3.13a 1/4" C.S. plate SF 0.0567 6mm C.S. plate SM 0.6103
51.3.13b 5/16" C.S. plate SF 0.0603 8mm C.S. plate SM 0.6036
51.3.13c 3/8" C.S. plate SF 0.0638 10mm C.S. plate SM 0.6867
51.3.13d 1/2" C.S. plate SF 0.0709 12mm C.S. plate SM 0.7631
51.3.14
51.3.14a 1/4" C.S. plate SF 0.0496 6mm C.S. plate SM 0.5337
51.3.14b 5/16" C.S. plate SF 0.0525 8mm C.S. plate SM 0.5207
51.3.14c 3/8" C.S. plate SF 0.0553 10mm C.S. plate SM 0.5951
51.3.14d 1/2" C.S. plate SF 0.0610 12mm C.S. plate SM 0.6566
51.3.15
51.3.15a Removal of Asphalt TON 1.7720 Removal of Asphalt MT 1.9537
51.3.15b Removal of Asphalt CY 2.4099 Removal of Asphalt CM 3.1519
51.3.15d Removal of Sand TON 1.2049 Removal of Sand MT 1.3284
51.3.15d Removal of Sand CY 1.7720 Removal of Sand CM 2.3175
51.3.1651.3.16a Removal of Asphalt TON 1.7720 Removal of Asphalt MT 1.9535
51.3.16b Removal of Asphalt CY 2.4099 Removal of Asphalt CM 3.1519
51.3.16c Removal of Sand TON 1.2049 Removal of Sand MT 1.3284
51.3.16d Removal of Sand CY 1.7720 Removal of Sand CM 2.3176
Removal of tank bottom plates in either sketch plat e or annular plate type bottoms Remove existing floor and annular plates, h ot work permissible. Store in area inside the tank battery limit or dire ctly outside the tank battery limit and subsequent loadin
Removal of sand and asphalt from tank bottom (Float ing Roof Tank)
Removal of sand and asphalt from tank bottom (Cone Roof Tank) Removal of sand and asphalt from tank bot tom (Cone Roof Tank)
Removal of sand and asphalt from tank bottom (Float ing Roof Tank)
Removal of tank bottom plates in either sketch plat e or annular plate type bottoms Remove existing floor and annular plates, h ot work permissible. Store in area inside the tank battery limit or dire ctly outside the tank battery limit and subsequent loadin
Removal of tank bottom plates in either sketch plat e or annular plate type bottoms Using a method of cold cutting, remove exis ting tank floor and annular plates Store in area inside the tank batter y limit or directly outside the tank battery limit and sub
Removal of tank bottom plates in either sketch plat e or annular plate type bottoms Remove existing floor and annular plates, h ot work permissible. Store in area inside the tank battery limit or dire ctly outside the tank battery limit and subsequent loadin
Removal of tank bottom plates in either sketch plat e or annular plate type bottoms Using a method of cold cutting, remove exis ting tank floor and annular plates Store in area inside the tank batter y limit or directly outside the tank battery limit and sub
Removal of tank bottom plates in either sketch plat e or annular plate type bottoms Remove existing floor and annular plates, h ot work permissible. Store in area inside the tank battery limit or dire ctly outside the tank battery limit and subsequent loadin
Removal of tank bottom plates in either sketch plat e or annular plate type bottoms Using a method of cold cutting, remove exis ting tank floor and annular plates Store in area inside the tank batter y limit or directly outside the tank battery limit and sub
Removal of tank bottom plates in either sketch plat e or annular plate type bottoms Using a method of cold cutting, remove exis ting tank floor and annular plates Store in area inside the tank batter y limit or directly outside the tank battery limit and sub
273
P.2.3.2 Tank Bottom Fabricate & Install – Annular P late Design 51.3 BOTTOM WORK BOTTOM WORK
51.3.2
51.3.21
51.3.2101 Tanks less than or equal to 50' in diameter SF 0.8962 Tanks less than or equal to 15m in diameter SM 9.6462
51.3.2102 Tanks 51 ' to 90' in diameter SF 0.8892 Tanks 15m to 25m in diameter SM 9.5708
51.3.2103 Tanks 91' to 125' in diameter SF 0.8011 Tanks 30m to 40m in diameter SM 8.6227
51.3.2104 Tanks 126' to 160' in diameter SF 0.8011 Tanks 40m to 50m in diameter SM 8.6224
51.3.22
51.3.2201 Tanks less than or equal to 50' in diameter SF 0.9250 Tanks less than or equal to 15m in diameter SM 9.9563
51.3.2202 Tanks 51 ' to 90' in diameter SF 0.9044 Tanks 15m to 25m in diameter SM 9.7342
51.3.2203 Tanks 91' to 125' in diameter SF 0.8163 Tanks 30m to 40m in diameter SM 8.7862
51.3.2204 Tanks 126' to 160' in diameter SF 0.8145 Tanks 40m to 50m in diameter SM 8.7668
51.3.23
51.3.2301 Tanks 161' to 200' in diameter SF 0.7673 Tanks 50m to 60m in diameter SM 8.2589
51.3.2302 Tanks greater than 201' in diameter SF 0.7646 Tanks greater than 60m in diameter SM 8.2296
51.3.24
51.3.2401 Tanks 161' to 200' in diameter SF 0.7757 Tanks 50m to 60m in diameter SM 8.3490
51.3.2402 Tanks greater than 201' in diameter SF 0.7752 Tanks greater than 60m in diameter SM 8.3440
Annular plate. Fabricate and install 1/2" x 5' for tanks of the following diameters (Floating Roof Tank)
Tank Bottom Fabrication and Installation - Annular Plate DesignAnnular plate. Fabricate and install 10mm x 900mm f or tanks of the following diameters (Cone Roof Tank)
Annular plate. Fabricate and install 10mm x 1200mm for tanks of the following diameters (Cone Roof Tank)
Annular plate. Fabricate and install 12mm x 1200mm for tanks of the following diameters (Floating Roof Tank)
Annular plate. Fabricate and install 12mm x 1500mm for tanks of the following diameters (Floating Roof Tank)
Tank Bottom Fabrication and Installation - Annular Plate DesignAnnular plate. Fabricate and install 3/8" x 3' for tanks of the following diameters (Cone Roof Tank)
Annular plate. Fabricate and install 3/8" x 4' for tanks of the following diameters (Cone Roof Tank)
Annular plate. Fabricate and install 1/2" x 4' for tanks of the following diameters (Floating Roof Tank)
274
P.2.3.3 Tank Bottom Fabricate & Install - New Annul ar Plate Design 51.3 BOTTOM WORK BOTTOM WORK
51.3.3
51.3.31
51.3.3101 Tanks less than or equal to 50' in diameter SF 0.2249 Tanks less than or equal to 15m in diameter SM 2.4207
51.3.3102 Tanks 51' to 90' in diameter SF 0.1861 Tanks 15m to 25m in diameter SM 2.0031
51.3.3103 Tanks 91' to 120' in diameter SF 0.1662 Tanks 30m to 35m in diameter SM 1.7889
51.3.3104 Tanks 121' to 160' in diameter SF 0.1581 Tanks 35m to 50m in diameter SM 1.7017
51.3.3105 Tanks 161' to 200' in diameter SF 0.1490 Tanks 50m to 60m in diameter SM 1.6037
51.3.3106 Tanks greater than 201' in diameter SF 0.1410 Tanks greater than 60m in diameter SM 1.5178
51.3.32
51.3.3201 Tanks less than or equal to 50' in diameter SF 0.2222 Tanks less than or equal to 15m in diameter SM 2.3911
51.3.3202 Tanks 51' to 90' in diameter SF 0.1798 Tanks 15m to 25m in diameter SM 1.9353
51.3.3203 Tanks 91' to 120' in diameter SF 0.1660 Tanks 30m to 35m in diameter SM 1.7862
51.3.3204 Tanks 121' to 160' in diameter SF 0.1580 Tanks 35m to 50m in diameter SM 1.6999
51.3.3205 Tanks 161' to 200' in diameter SF 0.1478 Tanks 50m to 60m in diameter SM 1.5903
51.3.3206 Tanks greater than 201' in diameter SF 0.1402 Tanks greater than 60m in diameter SM 1.5091
51.3.33
51.3.3301 Tanks less than or equal to 50' in diameter SF 0.2194 Tanks less than or equal to 15m in diameter SM 2.3615
51.3.3302 Tanks 51' to 90' in diameter SF 0.1735 Tanks 15m to 25m in diameter SM 1.8674
51.3.3303 Tanks 91' to 120' in diameter SF 0.1657 Tanks 30m to 35m in diameter SM 1.7836
51.3.3304 Tanks 121' to 160' in diameter SF 0.1578 Tanks 35m to 50m in diameter SM 1.6984
51.3.3305 Tanks 161' to 200' in diameter SF 0.1465 Tanks 50m to 60m in diameter SM 1.5768
51.3.3306 Tanks greater than 201' in diameter SF 0.1394 Tanks greater than 60m in diameter SM 1.5005
51.3.34
51.3.3401 Tanks less than or equal to 50' in diameter SF 0.2442 Tanks less than or equal to 15m in diameter SM 2.6285
51.3.3402 Tanks 51' to 90' in diameter SF 0.2051 Tanks 15m to 25m in diameter SM 2.2076
51.3.3403 Tanks 91' to 120' in diameter SF 0.1802 Tanks 30m to 35m in diameter SM 1.9395
51.3.3404 Tanks 121' to 160' in diameter SF 0.1719 Tanks 35m to 50m in diameter SM 1.8503
51.3.3405 Tanks 161' to 200' in diameter SF 0.1640 Tanks 50m to 60m in diameter SM 1.7652
51.3.3406 Tanks greater than 201' in diameter SF 0.1568 Tanks greater than 60m in diameter SM 1.6877
New Annular Plate Design Tank bottom Fabricate & in stall new tank bottom excluding annular plate. Using 12mm material in accordance with specifications referenced in Section 4. (Floating R oof Tank)
New Annular Plate Design Tank bottom Fabricate & in stall new tank bottom excluding annular plate. Using 1/2" material in accordance with specifications referenced in Section 4. (Floating R oof Tank)
New Annular Plate Design Tank bottom Fabricate & in stall new tank bottom excluding annular plate. Using 6mm material in accordance with specifications referenced in Section 4. (Floating R oof Tank)
Tank Bottom Fabrication and Installation - New Annu lar Plate Design
New Annular Plate Design Tank bottom Field Fabricat e & install new tank bottom excluding annular plate. Using 8mm material in accordance with specifications referenced in Section 4. (Floating R oof Tank)
New Annular Plate Design Tank bottom Fabricate and install new tank bottom excluding annular plate. Using 10mm material in accordance with specifications referenced in Section 4. (Floating R oof Tank)
New Annular Plate Design Tank bottom Fabricate and install new tank bottom excluding annular plate. Using 3/8" material in accordance with specifications referenced in Section 4. (Floating R oof Tank)
New Annular Plate Design Tank bottom Fabricate & in stall new tank bottom excluding annular plate. Using 5/16" materia l in accordance with specifications referenced in Section 4. (Floating R oof Tank)
New Annular Plate Design Tank bottom Fabricate & in stall new tank bottom excluding annular plate. Using 1/4" material in accordance with specifications referenced in Section 4. (Floating R oof Tank)
Tank Bottom Fabrication and Installation - New Annu lar Plate Design
275
51.3.35
51.3.3501 Tanks less than or equal to 50' in diameter SF 0.2093 Tanks less than or equal to 15m in diameter SM 2.2528
51.3.3502 Tanks 51' to 90' in diameter SF 0.1705 Tanks 15m to 25m in diameter SM 1.8351
51.3.3503 Tanks 91' to 120' in diameter SF 0.1506 Tanks 30m to 35m in diameter SM 1.6211
51.3.3504 Tanks 121' to 160' in diameter SF 0.1347 Tanks 35m to 50m in diameter SM 1.4498
51.3.3505 Tanks 161' to 200' in diameter SF 0.1334 Tanks 50m to 60m in diameter SM 1.4358
51.3.3506 Tanks greater than 201' in diameter SF 0.1332 Tanks greater than 60m in diameter SM 1.4338
51.3.36
51.3.3601 Tanks less than or equal to 50' in diameter SF 0.2073 Tanks less than or equal to 15m in diameter SM 2.2307
51.3.3602 Tanks 51' to 90' in diameter SF 0.1720 Tanks 15m to 25m in diameter SM 1.8513
51.3.3603 Tanks 91' to 120' in diameter SF 0.1511 Tanks 30m to 35m in diameter SM 1.6258
51.3.3604 Tanks 121' to 160' in diameter SF 0.1356 Tanks 35m to 50m in diameter SM 1.4595
51.3.3605 Tanks 161' to 200' in diameter SF 0.1347 Tanks 50m to 60m in diameter SM 1.4493
51.3.3606 Tanks greater than 201' in diameter SF 0.1346 Tanks greater than 60m in diameter SM 1.4483
51.3.37
51.3.3701 Tanks less than or equal to 50' in diameter SF 0.2052 Tanks less than or equal to 15m in diameter SM 2.2087
51.3.3702 Tanks 51' to 90' in diameter SF 0.1735 Tanks 15m to 25m in diameter SM 1.8674
51.3.3703 Tanks 91' to 120' in diameter SF 0.1515 Tanks 30m to 35m in diameter SM 1.6307
51.3.3704 Tanks 121' to 160' in diameter SF 0.1365 Tanks 35m to 50m in diameter SM 1.4691
51.3.3705 Tanks 161' to 200' in diameter SF 0.1359 Tanks 50m to 60m in diameter SM 1.4627
51.3.3706 Tanks greater than 201' in diameter SF 0.1359 Tanks greater than 60m in diameter SM 1.4629
51.3.38
51.3.3801 Tanks less than or equal to 50' in diameter SF 0.2301 Tanks less than or equal to 15m in diameter SM 2.4767
51.3.3802 Tanks 51' to 90' in diameter SF 0.1909 Tanks 15m to 25m in diameter SM 2.0547
51.3.3803 Tanks 91' to 120' in diameter SF 0.1660 Tanks 30m to 35m in diameter SM 1.7867
51.3.3804 Tanks 121' to 160' in diameter SF 0.1507 Tanks 35m to 50m in diameter SM 1.6221
51.3.3805 Tanks 161' to 200' in diameter SF 0.1499 Tanks 50m to 60m in diameter SM 1.6134
51.3.3806 Tanks greater than 201' in diameter SF 0.1497 Tanks greater than 60m in diameter SM 1.6113
New Annular Plate Design Tank bottom Fabricate and install new tank bottom excluding annular plate. Using 1/2" material in accordance with specifications referenced in Section 4. (Cone Roof Tank)
New Annular Plate Design Tank bottom Fabricate and install new tank bottom excluding annular plate. Using 12mm material in accordance with specifications referenced in Section 4. (Cone Roof Tank)
New Annular Plate Design Tank bottom Field Fit-up & install new tank bottom excluding annular plate. Using 10mm material in accordance with specifications referenced in Section 4. (Cone Roof Tank)
New Annular Plate Design Tank bottom Fabricate and install new tank bottom excluding annular plate. Using 8mm material in accordance with specifications referenced in Section 4. (Cone Roof Tank)
New Annular Plate Design Tank bottom Fabricate and install new tank bottom excluding annular plate. Using 5/16" materia l in accordance with specifications referenced in Section 4. (Cone Roof Tank)
New Annular Plate Design Tank bottom Field Fit-up & install new tank bottom excluding annular plate. Using 3/8" material in accordance with specifications referenced in Section 4. (Cone Roof Tank)
New Annular Plate Design Tank bottom Fabricate and install new tank bottom excluding annular plate. Using 6mm material in accordance with specifications referenced in Section 4. (Cone Roof Tank)
New Annular Plate Design Tank bottom Fabricate and install new tank bottom excluding annular plate. Using 1/4" material in accordance with specifications referenced in Section 4. (Cone Roof Tank)
276
P.2.3.4 Tank Bottom Fabricate & Install - New Sketc h Plate Design 51.3 BOTTOM WORK BOTTOM WORK
51.3.4
51.3.41
51.3.4101 Tanks less than or equal to 50 ' in diameter SF 0.3695 Tanks less than or equal to 15m in diameter SM 3.9771
51.3.4102 Tanks 51' - 90 ' in diameter SF 0.2654 Tanks 15m - 25m in diameter SM 2.8566
51.3.4103 Tanks 91' - 120' in diameter SF 0.1733 Tanks 30m - 35m in diameter SM 1.8653
51.3.4104 Tanks exceeding 120' in diameter SF 0.1542 Tanks exceeding 35m in diameter SM 1.6597
51.3.42
51.3.4201 Tanks less than or equal to 50 ' in diameter SF 0.3830 Tanks less than or equal to 15m in diameter SM 4.1224
51.3.4202 Tanks 51' - 90 ' in diameter SF 0.2762 Tanks 15m - 25m in diameter SM 2.9723
51.3.4203 Tanks 91' - 120' in diameter SF 0.1819 Tanks 30m - 35m in diameter SM 1.9579
51.3.4204 Tanks exceeding 120' in diameter SF 0.1514 Tanks exceeding 35m in diameter SM 1.6295
51.3.43
51.3.4301 Tanks less than or equal to 50 ' in diameter SF 0.3965 Tanks less than or equal to 15m in diameter SM 4.2677
51.3.4302 Tanks 51' - 90 ' in diameter SF 0.2869 Tanks 15m - 25m in diameter SM 3.0880
51.3.4303 Tanks 91' - 120' in diameter SF 0.1905 Tanks 30m - 35m in diameter SM 2.0505
51.3.4304 Tanks exceeding 120' in diameter SF 0.1486 Tanks exceeding 35m in diameter SM 1.5995
51.3.44
51.3.4401 Tanks less than or equal to 50 ' in diameter SF 0.4214 Tanks less than or equal to 15m in diameter SM 4.5358
51.3.4402 Tanks 51' - 90 ' in diameter SF 0.3043 Tanks 15m - 25m in diameter SM 3.2753
51.3.4403 Tanks 91' - 120' in diameter SF 0.2085 Tanks 30m - 35m in diameter SM 2.2441
51.3.4404 Tanks exceeding 120' in diameter SF 0.1793 Tanks exceeding 35m in diameter SM 1.9299
Tank Bottom Fabrication and Installation - New Sket ch Plate Design.
Fabricate and install new sketch plate design tank bottom Use 10mm material in accordance with specifications referenc ed in Section 4. (Floating Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 8mm material in accordance with specifications referenc ed in Section 4. (Floating Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 12mm material in accordance with specifications referenc ed in Section 4. (Floating Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 1/2" material in accordance with specifications referenc ed in Section 4. (Floating Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 6mm material in accordance with specifications referenc ed in Section 4. (Floating Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 5/16" material in accordance with specifications referenc ed in Section 4. (Floating Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 1/4" material in accordance with specifications referenc ed in Section 4. (Floating Roof Tank)
Tank Bottom Fabrication and Installation - New Sket ch Plate Design.
Fabricate and install new sketch plate design tank bottom Use 3/8" material in accordance with specifications referenc ed in Section 4. (Floating Roof Tank)
277
51.3.45
51.3.4501 Tanks less than or equal to 50 ' in diameter SF 0.3128 Tanks less than or equal to 15m in diameter SM 3.3668
51.3.4502 Tanks 51' - 90 ' in diameter SF 0.2087 Tanks 15m - 25m in diameter SM 2.2463
51.3.4503 Tanks 91' - 120' in diameter SF 0.1591 Tanks 30m - 35m in diameter SM 1.7126
51.3.4504 Tanks exceeding 120' in diameter SF 0.1417 Tanks exceeding 35m in diameter SM 1.5250
51.3.46
51.3.4601 Tanks less than or equal to 50 ' in diameter SF 0.3263 Tanks less than or equal to 15m in diameter SM 3.5120
51.3.4602 Tanks 51' - 90 ' in diameter SF 0.2195 Tanks 15m - 25m in diameter SM 2.3620
51.3.4603 Tanks 91' - 120' in diameter SF 0.1677 Tanks 30m - 35m in diameter SM 1.8050
51.3.4604 Tanks exceeding 120' in diameter SF 0.1396 Tanks exceeding 35m in diameter SM 1.5026
51.3.47
51.3.4701 Tanks less than or equal to 50 ' in diameter SF 0.3398 Tanks less than or equal to 15m in diameter SM 3.6574
51.3.4702 Tanks 51' - 90 ' in diameter SF 0.2302 Tanks 15m - 25m in diameter SM 2.4777
51.3.4703 Tanks 91' - 120' in diameter SF 0.1763 Tanks 30m - 35m in diameter SM 1.8976
51.3.4704 Tanks exceeding 120' in diameter SF 0.1375 Tanks exceeding 35m in diameter SM 1.4799
51.3.48
51.3.4801 Tanks less than or equal to 50 ' in diameter SF 0.3647 Tanks less than or equal to 15m in diameter SM 3.9255
51.3.4802 Tanks 51' - 90 ' in diameter SF 0.2476 Tanks 15m - 25m in diameter SM 2.6650
51.3.4803 Tanks 91' - 120' in diameter SF 0.1943 Tanks 30m - 35m in diameter SM 2.0913
51.3.4804 Tanks exceeding 120' in diameter SF 0.1652 Tanks exceeding 35m in diameter SM 1.7781
Fabricate and install new sketch plate design tank bottom Use 10mm material in accordance with specifications referenc ed in Section 4. (Cone Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 12mm material in accordance with specifications referenc ed in Section 4. (Cone Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 3/8" material in accordance with specifications referenc ed in Section 4. (Cone Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 1/2" material in accordance with specifications referenc ed in Section 4. (Cone Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 6mm material in accordance with specifications referenc ed in Section 4. (Cone Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 1/4" material in accordance with specifications referenc ed in Section 4. (Cone Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 5/16" material in accordance with specifications referenc ed in Section 4. (Cone Roof Tank)
Fabricate and install new sketch plate design tank bottom Use 8mm material in accordance with specifications referenc ed in Section 4. (Cone Roof Tank)
278
P.2.3.5 Lap Patching (Overplate) 51.3 BOTTOM WORK BOTTOM WORK
51.3.5 Lap Patching (Overplate) Lap Patching (Overplate)51.3.51 Lap Patch 1/4" C.S. plate Lap Patch 6mm C.S. plate
51.3.51A Lap patches 5 sq ft or less Lap patches 0.5 sq m or less51.3.51a01 Quantity 1 - 5 LF 0.3091 Quantity 1 - 5 LM 1.0141
51.3.51a02 Quantity 6 - 10 LF 0.3009 Quantity 6 - 10 LM 0.9872
51.3.51a03 Quantity 11 - 15 LF 0.2935 Quantity 11 - 15 LM 0.9629
51.3.51a04 Quantity 16 - 20 LF 0.2844 Quantity 16 - 20 LM 0.9331
51.3.51a05 Quantity 21+ LF 0.2783 Quantity 21+ LM 0.9130
51.3.51b Lap patches 5 to 20 sq ft Lap patches 0.5 to 2.0 sq m51.3.51b01 Quantity 1 - 5 LF 0.2886 Quantity 1 - 5 LM 0.9468
51.3.51b02 Quantity 6 - 10 LF 0.2799 Quantity 6 - 10 LM 0.9183
51.3.51b03 Quantity 11 - 15 LF 0.2741 Quantity 11 - 15 LM 0.8993
51.3.51b04 Quantity 16 - 20 LF 0.2684 Quantity 16 - 20 LM 0.8806
51.3.51b05 Quantity 21+ LF 0.2597 Quantity 21+ LM 0.8520
51.3.51c Lap patches 20 to 40 sq ft Lap patches 2.0 to 4.0 sq m51.3.51c01 Quantity 1 - 5 LF 0.2721 Quantity 1 - 5 LM 0.8927
51.3.51c02 Quantity 6 - 10 LF 0.2639 Quantity 6 - 10 LM 0.8658
51.3.51c03 Quantity 11 - 15 LF 0.2584 Quantity 11 - 15 LM 0.8478
51.3.51c04 Quantity 16 - 20 LF 0.2530 Quantity 16 - 20 LM 0.8300
51.3.51c05 Quantity 21+ LF 0.2449 Quantity 21+ LM 0.8035
51.3.51d Lap patches 40 to 75 sq ft Lap patches 4.0 to 7.0 sq m51.3.51d01 Quantity 1 - 5 LF 0.2638 Quantity 1 - 5 LM 0.8655
51.3.51d02 Quantity 6 - 10 LF 0.2559 Quantity 6 - 10 LM 0.8396
51.3.51d03 Quantity 11 - 15 LF 0.2506 Quantity 11 - 15 LM 0.8222
51.3.51d04 Quantity 16 - 20 LF 0.2453 Quantity 16 - 20 LM 0.8048
51.3.51d05 Quantity 21+ LF 0.2374 Quantity 21+ LM 0.7789
51.3.51e Lap patches greater than 75 sq ft Lap patches greater than 7.0 sq m51.3.51f01 Quantity 1 - 5 LF 0.2473 Quantity 1 - 5 LM 0.8113
51.3.51f02 Quantity 6 - 10 LF 0.2399 Quantity 6 - 10 LM 0.7871
51.3.51f03 Quantity 11 - 15 LF 0.2350 Quantity 11 - 15 LM 0.7710
51.3.51f04 Quantity 16 - 20 LF 0.2300 Quantity 16 - 20 LM 0.7546
51.3.51f05 Quantity 21+ LF 0.2226 Quantity 21+ LM 0.7303
279
P.2.3.6 Pads 51.3.6 Pads Pads
51.3.61
51.3.61a Size 2' x 2' EA 17.0108 Size 600mm x 600mm EA 17.0108
51.3.61b Size 4' x 4' EA 19.8460 Size 1200mm x 1200mm EA 19.8460
51.3.62
51.3.62a Size 2' x 2' EA 14.1757 Size 600mm x 600mm EA 14.1757
51.3.62b Size 4' x 4' EA 17.0108 Size 1200mm x 1200mm EA 17.0108
51.3.63
51.3.63a 3/8" x 18" x 18" C.S. plate EA 4.2814 10mm x 450mm x 450mm C.S. plate EA 4.2814
51.3.63b 3/8" x 24" x 24" C.S. plate EA 4.6956 10mm x 600mm x 600mm C.S. plate EA 4.6956
51.3.63c 1/2" x 18" x 18" C.S. plate EA 4.9984 12mm x 450mm x450mm C.S. plate EA 4.9984
51.3.63d 1/2" x 24" x 24" C.S. plate EA 5.4189 12mm x 600mmx 600mm C.S. plate EA 5.4189
51.3.63e 1/8" x 12" x 12" 304 S.S. plate EA 3.5635 28mm x 300mm x 300mm 304 S.S. plate EA 3.5635
51.3.63f 1/8" x 18" x 18" 304 S.S. plate EA 4.3628 28mm x 450mm x 450mm 304 S.S. plate EA 4.3628
51.3.63g 1/8" x 24" x 24" 304 S.S. plate EA 4.7888 28mm x 600mm x 600mm 304 S.S. plate EA 4.7888
Floating Roof Support Leg Pads Install pre-coated o r non-coated pads underneath roof support legs Multi-seal pass weld w ith 100% vacuum box test required. Document vacuum box test in quality control records
Cone Roof column pads Install 3/8" Carbon Steel pad s under roof columns Multi-pass weld required. 100% vacuum box test requ ired. Place anti-rotation clips at each corner of column base plate.
Cone Roof column pads Install 1/2" Carbon Steel pad s under roof columns Multi-pass weld required. 100% vacuum box test requ ired. Place anti-rotation clips at each corner of column base plate.
Cone Roof column pads Install 12mm Carbon Steel pad s under roof columns Multi-pass weld required. 100% vacuum box t est required. Place anti-rotation clips at each corner of column base p late.
Cone Roof column pads Install 10mm Carbon Steel pad s under roof columns Multi-pass weld required. 100% vacuum box t est required. Place anti-rotation clips at each corner of column base p late.
Floating Roof Support Leg Pads Install pre-coated o r non-coated pads underneath roof support legs Multi-seal pass weld w ith 100% vacuum box test required. Document vacuum box test in quality control records
280
P.2.3.7 Sumps 51.3 BOTTOM WORK BOTTOM WORK
51.3.7 Sumps Sumps
51.3.71
51.3.7101 24" weld cap type sump EA 31.1420 600mm weld cap type sump EA 31.1420
51.3.7102 API 650 type sump EA 37.8078 API 650 type sump EA 37.8078
51.3.7251.3.7201 24" weld cap type sump EA 31.1420 600mm weld cap type sump EA 31.1420
51.3.7202 API 650 type sump EA 37.8078 API 650 type sump EA 37.8078
51.3.7351.3.7301 Shallow sump not exceeding 24" diameter. EA 37.8078 Shallow sump not exceeding 600mm diameter. EA 37.8078
51.3.7302 Shallow sump not exceeding 36" diameter. EA 49.2347 Shallow sump not exceeding 900mm diameter. EA 49.2347
Fabricate and install new shallow Sump for double b ottom Fabricate and install new shallow Sump for dou ble bottom
Bottom sump. Fabricate and install new standard wei ght cup and straw sump for existing sump with asphalt/ concrete fille r up to 24" sump. Vacuum box test required. In accordance with specif ications referenced in Section 4.
Bottom sump. Fabricate and install new standard wei ght cup and straw sump for existing sump with asphalt/ concrete fille r up to 600mm sump. Vacuum box test required. In accordance with specif ications referenced in Section 4.
Fabricate and install new Bottom Sump for existing bottomFabricate and install new Bottom Sump for existing bottom
281
P.2.3.8 Tank Bottom Beds & Linings 51.3.8 Tank Bottom Beds and Linings Tank Bottom Beds and Linings
51.3.81
51.3.81a Minimum of 4" thick cold mix asphalt (1.35 tons/cy) TON 2.4807 Minimum of 100mm thick cold mix asphalt (1.6 tonnes/cm) MT 2.7349
51.3.81b Minimum of 4" thick Hot mix asphalt (1.35 tons/cy) TON 2.4807 Minimum of 100mm thick hot mix asphalt (1.6 tonnes/cm) MT 2.7349
51.3.81c Minimum of 4" thick oiled sand CY 2.4807 Minimum of 100mm thick oiled sand CM 3.2444
51.3.81d Minimum 4" thick concrete (6,000 lb.) CY 5.3159 Minimum 100mm thick concrete (41.369 MPa) CM 6.9527
51.3.82
51.3.82a Minimum of 4" thick cold mix asphalt (1.35 tons/cy) TON 2.2681 Minimum of 100mm thick cold mix asphalt (1.6 tonnes/cm) MT 2.5005
51.3.82b Minimum of 4" thick Hot mix asphalt (1.35 tons/cy) TON 2.2681 Minimum of 100mm thick hot mix asphalt (1.6 tonnes/cm) MT 2.5006
51.3.82c Minimum of 4" thick oiled sand CY 2.2681 Minimum of 100mm thick oiled sand CM 2.9664
51.3.82d Minimum 4" thick concrete (6,000 lb.) CY 5.3159 Minimum 100mm thick concrete (41.369 MPa) CM 6.9527
51.3.83 Install blown in sand for tank bottom Install blown in sand for tank bottom51.3.83a Minimum of 4" thick sand (floating roof tank) CY 3.1895 Minimum of 100mm thick sand (floating roof tank) CM 4.1717
51.3.83b Minimum of 4" thick sand (cone roof tank) CY 2.8351 Minimum of 100mm thick sand (cone roof tank) CM 3.7080
51.3.84 Install liner. Install liner.51.3.84a Petroguard 8 supplied by mP.C. SY 0.1439 Petroguard 8 supplied by mP.C. SM 0.1721
51.3.84b Petroguard 10 supplied by mP.C. SY 0.1439 Petroguard 10 supplied by mP.C. SM 0.1721
51.3.84d HDPE 40 mil thickness SY 0.1439 HDPE 1mm thickness SM 0.1721
51.3.84e HDPE 60 mil thickness SY 0.1439 HDPE 1.5mm thickness SM 0.1721
51.3.84f HDPE 80 mil thickness SY 0.1439 HDPE 2mm thickness SM 0.1721
51.3.84g Modified Polypropylene 45 mil thickness SY 0.1439 Modified Polypropylene 1.1mm thickness SM 0.1721
51.3.85 Bolting of liner at perimeter Bolting of liner at perimeter51.3.85a Petroguard 8 supplied by mP.C. LF 0.5079 Petroguard 8 supplied by mP.C. LM 1.6663
51.3.85b Petroguard 10 supplied by mP.C. LF 0.5079 Petroguard 10 supplied by mP.C. LM 1.6663
51.3.85c Petroguard 12 supplied by mP.C. LF 0.5079 Petroguard 12 supplied by mP.C. LM 1.6663
51.3.85d HDPE 40 mil thickness LF 0.5079 HDPE 1mm thickness LM 1.6663
51.3.85f HDPE 60 mil thickness LF 0.5079 HDPE 1.5mm thickness LM 1.6663
51.3.85g HDPE 80 mil thickness LF 0.5079 HDPE 2mm thickness LM 1.6663
51.3.85h Modified Polypropylene 45 mil thickness LF 0.5079 Modified Polypropylene 1.1mm thickness LM 1.6663
Install asphalt, sand, and concrete for tank bottom where motorized equipment can be used (Cone Roof Tank)
Install asphalt, sand, and concrete for tank bottom where motorized equipment can be used (Floating Roof Tank)
Install asphalt, sand, and concrete for tank bottom where motorized equipment can be used (Floating Roof Tank)
Install asphalt, sand, and concrete for tank bottom where motorized equipment can be used (Cone Roof Tank)
282
P.2.3.9 Preparation for Inspection 51.3 BOTTOM WORK BOTTOM WORK
51.3.9 Preparation For Inspection Preparation For Inspection51.3.91 LEL test of the floor for hot work. LEL test of the floor for hot work.51.3.91a Drill holes in floor for LEL gas testing. (Qty 1-10) EA 0.3544 Drill holes in floor for LEL gas testing. (Qty 1-10) EA 0.3544
51.3.91b Drill holes in floor for LEL gas testing. (Qty >10) EA 0.3544 Drill holes in floor for LEL gas testing. (Qty >10) EA 0.3544
51.3.91c Patch holes with 1/4"-6" D lap patches (Qty 1-10) EA 0.9654 Patch holes with 6mm-150mm D lap patches (Qty 1-10) EA 0.9654
51.3.91d Patch holes with 1/4"-6" D lap patches (Qty >10) EA 0.8801 Patch holes with 6mm-150mm D lap patches (Qty >10) EA 0.8801
51.3.92 Grind tank bottom for UT inspection. Grind tank bottom for UT inspection.51.3.92a 8" x 8" minimum of 15 locations EA 0.3544 200mm x 200mm minimum of 15 locations EA 0.3544
51.3.92b 2' x 2' minimum of 15 locations EA 1.0632 600mm x 600mm minimum of 15 locations EA 1.0632
283
P.2.4 Ancillary Work
P.2.4.1 Demolition and Removal Work 51.5 ANCILLARY WORK ANCILLARY WORK
51.5.1 Demolition and Removal Work Demolition and Removal Work51.5.11 Mixers Mixers
51.5.11a Remove tank mixer. Electrical connection done by others (Typical mixer is in a 30" manway.)
EA 14.1757 Remove tank mixer. Electrical connection done by others (Typical mixer is in a 750mm manway.)
EA 14.1757
51.5.12 Handrail and Toe-plates (hot work permissible) Handrail and Toe-plates (hot work permissible)51.5.12a Remove existing handrail and posts LF 0.4253 Remove existing handrail and posts LM 1.3953
51.5.12b Remove existing toe-plates LF 0.1418 Remove existing toe-plates LM 0.4652
51.5.13 Tank stairways and platforms Tank stairways and platforms51.5.13a Remove stairway tread. Bolt in place type. EA 2.8351 Remove stairway tread. Bolt in place type. EA 2.8351
51.5.13b Remove stairway tread. Weld in place type EA 3.5439 Remove stairway tread. Weld in place type EA 3.5439
51.5.13c Remove tank access stairway - Single string type LF 2.8351 Remove tank access stairway - Single string type LM 9.3014
51.5.13d Remove tank access stairway - Double string type LF 3.5439 Remove tank access stairway - Double string type LM 11.6267
51.5.13e Remove stairway landing / platform - top or intermediate SF 4.2527 Remove stairway landing / platform - top or intermediate SM 45.7735
51.5.13f Remove floating roof access stairway LF 0.3544 Remove floating roof access stairway LM 1.1627
51.5.13g Remove safety gate EA 5.6703 Remove safety gate EA 5.6703
51.5.13h Remove vertical access ladder LF 0.4961 Remove vertical access ladder LM 1.6275
51.5.14 Foam Chambers Foam Chambers 51.5.14a Remove foam chambers EA 8.5054 Remove foam chambers EA 8.5054
51.5.15 Seals Seals51.5.15a Remove existing liquid filled seal LF 0.2250 Remove existing liquid filled seal LM 0.7382
51.5.15b Remove pantograph seal and sealing ring plate not exceeding 15ft LF 1.3850 Remove pantograph seal and sealing ring plate not exceeding 5m LM 4.5439
51.5.15c Remove pantograph seal and sealing ring plate 15ft - 150ft LF 0.8500 Remove pantograph seal and sealing ring plate 5m - 50m LM 2.7887
51.5.15d Remove pantograph seal and sealing ring plate exceeding 150ft LF 0.6000 Remove pantograph seal and sealing ring plate exceeding 50m LM 1.9685
51.5.15e Remove secondary seals not exceeding 15ft LF 0.4500 Remove secondary seals not exceeding 5m LM 1.4764
51.5.15f Remove secondary seals 15ft - 150ft LF 0.4250 Remove secondary seals 5m - 50m LM 1.3943
51.5.15g Remove secondary seals exceeding 150ft LF 0.1700 Remove secondary seals exceeding 50m LM 0.5577
284
P.2.4.2 Re-installation of Existing Components 51.5.2 Re-installation of Existing Components Re-installation of Existing Components51.5.21 Mixers Mixers
51.5.21a Re-installation of tank mixer. Electrical connection done by others (Typical mixer is in a 30" manway.)
EA 14.1757 Re-installation of tank mixer. Electrical connection done by others (Typical mixer is in a 750mm manway.)
EA 14.1757
51.5.22 Handrail and Toe-plates (hot work permissible) Handrail and Toe-plates (hot work permissible)51.5.22a Re-installation of existing handrail and posts LF 0.6379 Re-installation of existing handrail and posts LM 2.0927
51.5.22b Re-installation of existing toe-plates LF 0.2126 Re-installation of existing toe-plates LM 0.6974
51.5.23 Tank stairways and platforms Tank stairways and platforms51.5.23a Re-installation of stairway tread. Bolt in place type. EA 3.5439 Re-installation of stairway tread. Bolt in place type. EA 3.5439
51.5.23b Re-installation of stairway tread. Weld in place type EA 6.3791 Re-installation of stairway tread. Weld in place type EA 6.3791
51.5.23c Re-installation of tank access stairway - Single string type LF 3.5439 Re-installation of tank access stairway - Single string type LM 11.6267
51.5.23d Re-installation of tank access stairway - Double string type LF 4.2527 Re-installation of tank access stairway - Double string type LM 13.9523
51.5.23e Re-installation of stairway landing / platform - top or intermediate SF 4.2527 Re-installation of stairway landing / platform - top or intermediate SM 45.7734
51.5.23f Re-installation of floating roof access stairway LF 0.3544 Re-installation of floating roof access stairway LM 1.1627
51.5.23g Re-installation of safety gate EA 8.5054 Re-installation of safety gate EA 8.5054
51.5.23h Re-installation of vertical access ladder LF 0.5670 Re-installation of vertical access ladder LM 1.8602
51.5.24 Foam Chambers Foam Chambers 51.5.24a Re-installation of foam chambers EA 14.1757 Re-installation of foam chambers EA 14.1757
51.5.25 Seals Seals51.5.25a Re-install existing liquid filled seal LF 0.3118 Re-install existing liquid filled seal LM 1.0230
51.5.25b Re-install pantograph seal and sealing ring plate not exceeding 15ft LF 1.2500 Re-install pantograph seal and sealing ring plate not exceeding 5m LM 4.1010
51.5.25c Re-install pantograph seal and sealing ring plate 15ft - 150ft LF 0.6800 Re-install pantograph seal and sealing ring plate 5m - 50m LM 2.2309
51.5.25d Re-install pantograph seal and sealing ring plate exceeding 150ft LF 0.6100 Re-install pantograph seal and sealing ring plate exceeding 50m LM 2.0013
51.5.25e Re-install secondary seals not exceeding 15ft LF 0.4535 Re-install secondary seals not exceeding 5m LM 1.4878
51.5.25f Re-install secondary seals 15ft - 150ft LF 0.4250 Re-install secondary seals 5m - 50m LM 1.3943
51.5.25g Re-install secondary seals exceeding 150ft LF 0.3825 Re-install secondary seals exceeding 50m LM 1.2549
285
P.2.4.3 Fabrication & Installation of New Component s 51.5 ANCILLARY WORK ANCILLARY WORK
51.5.3 Fabrication & Installation of New Components Fabrication & Installation of New Components51.5.31 Mixers Mixers
51.5.31a Fabrication and Installation of tank mixer. Electrical connection done by others (Typical mixer is in a 30" manway.)
EA 37.8928 Fabrication and Installation of tank mixer. Electrical connection done by others (Typical mixer is in a 750mm manway.)
EA 37.8928
51.5.3251.5.32 Fabricate and install handrail and posts Fabricate and install handrail and posts51.5.3201 1/4" x 2" x 2" Angle C.S. LF 0.7167 6mm x 50mm x 50mm Angle C.S. LM 2.3513
51.5.3202 1/4" x 2 1/2" x 2 1/2" Angle C.S. LF 0.7182 6mm x 65mm x 65mm Angle C.S. LM 2.3562
51.5.3203 1/4" x 2" Flat bar C.S. LF 0.4283 6mm x 50mm Flat bar C.S. LM 1.4052
51.5.3204 1/4" x 2 1/2" Flat bar C.S. LF 0.4287 6mm x 65mm Flat bar C.S. LM 1.4065
51.5.3205 Toe-plates 1/4" X 6" Flat bar C.S.. LF 0.4359 Toe-plates 6mm X 150mm Flat bar C.S.. LM 1.4301
51.5.3206 1/4" x 2" x 2" Angle (Galv) LF 0.7184 6mm x 50mm x 50mm Angle (Galv) LM 2.3569
51.5.3207 1/4" x 2 1/2" x 2 1/2" Angle (Galv) LF 0.7207 6mm x 65mm x 65mm Angle (Galv) LM 2.3645
51.5.3208 1/4" x 2" Flat bar (Galv) LF 0.4288 6mm x 50mm Flat bar (Galv) LM 1.4068
51.5.3209 1/4" x 2 1/2" Flat bar (Galv) LF 0.4293 6mm x 65mm Flat bar (Galv) LM 1.4084
51.5.3210 Toe-plates 1/4" X 6" Flat bar (Galv) LF 0.4374 Toe-plates 6mm X 150mm Flat bar (Galv) LM 1.4350
51.5.3351.5.3301 Stairway tread. Bolt in place type. EA 3.6286 Stairway tread. Bolt in place type. EA 3.6286
51.5.3302 Stairway tread. Weld in place type EA 6.4638 Stairway tread. Weld in place type EA 6.4638
51.5.3303 Tank access stairway - Single string type LF 3.7659 Tank access stairway - Single string type LM 12.3550
51.5.3304 Tank access stairway - Double string type LF 4.5229 Tank access stairway - Double string type LM 14.8388
51.5.3305 Stairway landing / platform - top or intermediate SF 4.5204 Stairway landing / platform - top or intermediate SM 48.6549
51.5.3306 Floating roof access stairway LF 0.7108 Floating roof access stairway LM 2.3320
51.5.3307 Safety gate EA 8.6840 Safety gate EA 8.6840
51.5.3308 Vertical access ladder LF 0.8068 Vertical access ladder LM 2.6469
51.5.34 Fabricate and install Foam Chambers Fabricate and install Foam Chambers51.5.3401 Foam chambers EA 14.1757 Foam chambers EA 14.1757
51.5.35 Seals Seals51.5.35a Install existing liquid filled seal LF 0.3400 Install existing liquid filled seal LM 1.1155
51.5.35b Install pantograph seal and sealing ring plate not exceeding 15ft LF 0.7650 Install pantograph seal and sealing ring plate not exceeding 5m LM 2.5098
51.5.35c Install pantograph seal and sealing ring plate 15ft - 150ft LF 0.7250 Install pantograph seal and sealing ring plate 5m - 50m LM 2.3786
51.5.35d Install pantograph seal and sealing ring plate exceeding 150ft LF 0.7000 Install pantograph seal and sealing ring plate exceeding 50m LM 2.2966
51.5.35e Install secondary seals not exceeding 15ft LF 0.4500 Install secondary seals not exceeding 5m LM 1.4764
51.5.35f Install secondary seals 15ft - 150ft LF 0.4200 Install secondary seals 5m - 50m LM 1.3779
51.5.35g Install secondary seals exceeding 150ft LF 0.4000 Install secondary seals exceeding 50m LM 1.3123
Handrail and Toe-plates (hot work permissible)Handrail and Toe-plates (hot work permissible)
Fabricate and install tank stairways and platforms F abricate and install tank stairways and platforms
286
P.2.4.4 Ladder Assemblies 51.5.4 Ladder Assemblies Ladder Assemblies51.5.41 Ladder Track Assembly. Ladder Track Assembly. 51.5.41a Removal of ladder track assembly and replacement with new. LF 1.4176 Removal of ladder track assembly and replacement with new. LM 4.6508
51.5.42 Ladder Wheel Assembly. Ladder Wheel Assembly. 51.5.42a Removal of ladder wheel assembly and replacement with new. EA 11.3406 Removal of ladder wheel assembly and replacement with new. EA 11.3406
P.2.4.5 Testing 51.5.5 Testing Testing51.5.53 Hydro test Tanks Hydro test Tanks51.5.53a Connect 1 1/2" x 50' sections of threaded water hoses EA 8.5054 Connect 40mm x 15m sections of threaded water hoses EA 8.5054
51.5.53b Connect 2 1/2" x 50' sections of threaded water hoses EA 9.2142 Connect 65mm x 15m sections of threaded water hoses EA 9.2142
51.5.53c Connect 5" x 20' sections of fire hose flanged water hoses EA 9.9230 Connect 125mm x 6m sections of fire hose flanged water hoses EA 9.9230
51.5.54 Vacuum box test existing welds Vacuum box test existing welds51.5.54a 0 - 165' weld LF 0.0500 0 - 50m weld LM 0.1640
51.5.54b 165' weld and above LF 0.0280 50m weld and above LM 0.0919
P.2.4.6 Tank Builders Scaffold 51.5.6 Tank Builders Scaffolding Tank Builders Scaffolding
51.5.61
51.5.61a Special tank scaffold first lift LF 0.4961 Special tank scaffold first lift LM 1.6276
Erect/Dismantle special tank scaffold Unit fully de cked out with boarding, handrails and access
Erect/Dismantle special tank scaffold Unit fully de cked out with boarding, handrails and access
P.2.5 Tank Jacking
P.2.5.1 Tank Jacking 51.6.1 Tank Jacking Tank Jacking51.6.11 Tank Jacking Tank Jacking51.6.11a Tanks less than or equal to 50' in diameter ea Tanks less than or equal to 15m in diameter ea
51.6.11b Tanks 51' - 90' in diameter ea Tanks 15m - 30m in diameter ea
51.6.11c Tanks 91' - 125' in diameter ea Tanks 30m - 40m in diameter ea
51.6.11d Tanks 126' - 160' in diameter ea Tanks 40m - 50m in diameter ea
51.6.11e Tanks 160' - 190' in diameter ea Tanks 50m - 60m in diameter ea
51.6.11f Tanks 191' - 220' in diameter ea Tanks 60m - 70m in diameter ea
51.6.11g Tanks greater than 221' in diameter ea Tanks greater than 70m in diameter ea
287
P.2.5.2 Welding 51.6.2 Welding Welding51.6.21 Gouge out to remove indications and reweld Gouge out to remove indications and reweld51.6.21a Butt welds LF 0.5000 Butt welds LM 1.6404
51.6.21b Fillet welds LF 0.2500 Fillet welds LM 0.8202
51.6.21c Internal Corner welds LF 0.3600 Internal Corner welds LM 1.1811
51.6.21d Sump wall lip seam welds LF 0.5000 Sump wall lip seam welds LM 1.6404
51.6.22 Weld Overlay Weld Overlay51.6.21a Build up weld in single runs LF 0.0940 Build up weld in single runs LM 0.3084
51.6.2351.6.23a 1/4" C.S. plate LF 6mm C.S. plate LM
51.6.23b 5/16" C.S. plate LF 8mm C.S. plate LM
51.6.23c 3/8" C.S. plate LF 10mm C.S. plate LM
51.6.23d 1/2" C.S. plate LF 12mm C.S. plate LM
51.6.23e 9/16" C.S. plate LF 14mm C.S. plate LM
51.6.23f 5/8" C.S. plate LF 16mm C.S. plate LM
51.6.23g 3/4" C.S. plate LF 19mm C.S. plate LM
51.6.23h 7/8" C.S. plate LF 22mm C.S. plate LM
51.6.23i 1" C.S. plate LF 25mm C.S. plate LM
51.6.23j 1-1/8" C.S. plate LF 28mm C.S. plate LM
51.6.23k 1-1/4" C.S. plate LF 32mm C.S. plate LM
51.6.23l 1-3/8" C.S. plate LF 35mm C.S. plate LM
51.6.23m 1-1/2" C.S. plate LF 38mm C.S. plate LM
51.6.23n less than 2" nozzles Each less than 50mm roof nozzles Each
51.6.23o 2" nozzles Each 50mm nozzles Each
51.6.23p 3" nozzles Each 80mm nozzles Each
51.6.23q 4" nozzles Each 100mm nozzles Each
51.6.23r 5" nozzles Each 125mm nozzles Each
51.6.23s 6" nozzles Each 150mm nozzles Each
51.6.23t 8" nozzles Each 200mm nozzles Each
51.6.23u 10" nozzles Each 250mm nozzles Each
51.6.23v 12" nozzles Each 300mm nozzles Each
51.6.23w 14" nozzles Each 350mm nozzles Each
51.6.23x 16" nozzles Each 400mm nozzles Each
51.6.23y 18" nozzles Each 450mm nozzles Each
51.6.23z 20" nozzles Each 500mm nozzles Each
51.6.23aa 22" nozzles Each 550mm nozzles Each
51.6.23bb 24" nozzles Each 600mm nozzles Each
Post Weld Heat Treatment Required for Welding: Post Weld Heat Treatment Required for Welding:
288
Q.1 Civil & Building Norms
Q.2.1.1 Groundworks
EXCAVATION AND FILLING
SITE PREPARATION
Clear site of vegetation; generally; m2 0.05 ft2 0.00
EARTHWORKS
Excavate (by hand)
Excavate; reduce levels maximum depth n e 0.25m m3 1.66 yd3 1.27
maximum depth n e 1.00m m3 1.60 yd3 1.22
maximum depth n e 2.00m m3 1.77 yd3 1.35
maximum depth n e 4.00m m3 1.88 yd3 1.43
Excavate; basement and the like maximum depth n e 0.25m m3 1.70 yd3 1.30
maximum depth n e 1.00m m3 1.65 yd3 1.26
maximum depth n e 2.00m m3 1.81 yd3 1.38
maximum depth n e 4.00m m3 1.92 yd3 1.47
Excavate; pit (isolated) maximum depth n e 0.25m m3 1.77 yd3 1.35
maximum depth n e 1.00m m3 1.71 yd3 1.31
maximum depth n e 2.00m m3 1.99 yd3 1.52
maximum depth n e 4.00m m3 2.21 yd3 1.69
Excavate; pit (more than I Nr)) maximum depth n e 0.25m m3 1.70 yd3 1.30
maximum depth n e 1.00m m3 1.65 yd3 1.26
maximum depth n e 2.00m m3 1.81 yd3 1.38
maximum depth n e 4.00m m3 1.92 yd3 1.47
Excavate; trench n e 300mm width; maximum depth n e 0.25m m3 1.70 yd3 1.30
n e 300mm width; maximum depth n e 1.00m m3 1.65 yd3 1.26
n e 300mm width; maximum depth n e 2.00m m3 1.81 yd3 1.38
n e 300mm width; maximum depth n e 4.00m m3 1.92 yd3 1.47
over 300mm width; maximum depth n e 0.25m m3 1.48 yd3 1.13
over 300mm width; maximum depth n e 1.00m m3 1.65 yd3 1.26
over 300mm width;; maximum depth n e 2.00m m3 1.81 yd3 1.38
over 300mm width; maximum depth n e 4.00m m3 1.92 yd3 1.47
maximum depth n e 0.25m m3 1.48 yd3 1.13
maximum depth n e 1.00m m3 1.65 yd3 1.26
maximum depth n e 2.00m m3 1.81 yd3 1.38
maximum depth n e 4.00m m3 1.92 yd3 1.47
maximum depth n e 0.25m m3 1.55 yd3 1.18
maximum depth n e 1.00m m3 1.49 yd3 1.14
maximum depth n e 2.00m m3 1.66 yd3 1.27
maximum depth n e 4.00m m3 1.77 yd3 1.35
Extra over excavation for working next to existing service; cable or cluster of cables; irrespective of depth m 0.22 ft 0.07
pipe: n e 200 diameter; irrespective of depth m 0.22 ft 0.07
pipe: over 200 n e 300 diameter; irrespective of depth m 0.22 ft 0.07
pipe: over 300 diameter; irrespective of depth m 0.33 ft 0.10
cluster of piping : n e 1m wide; irrespective of depth m 0.33 ft 0.10
Excavate; extra over for working around existing service; cable or cluster of cables, irrespective of depth Nr 0.88 Nr 0.88
pipe: n e 200 diameter; irrespective of depth Nr 0.88 Nr 0.88
pipe: over 200 n e 300 diameter; irrespective of depth Nr 0.88 Nr 0.88
pipe: over 300 diameter; irrespective of depth Nr 1.11 Nr 1.11
cluster of piping : n e 1m wide; irrespective of depth Nr 1.11 Nr 1.11
Excavate; extra over for working in material classified by the Client as contaminated under the provision of the Poisonous Waste Act 1972
irrespective of depth m3 1.13 yd3 0.86
Excavate; pile cap and ground beam
Excavate; remove earth bund
GROUNDWORKS Unit Unit Labour Norm Hrs.
Labour Norm Hrs.
New Work
289
rock; m3 2.92 yd3 2.23
mass concrete; m3 2.92 yd3 2.23
reinforced concrete; m3 4.67 yd3 3.56
coated macadam or asphalt paving; m3 1.17 yd3 0.89
brickwork or blockwork; m3 2.33 yd3 1.78
concrete paving; m3 2.92 yd3 2.23
reinforced concrete paving; m3 4.67 yd3 3.56
concrete paviors 65 thick; m2 0.21 yd3 0.16
brickwork and the like generally; at or above ground level m3 2.92 yd3 2.23
reinforced concrete generally; at or above ground level m3 4.37 yd3 3.34
brickwork fireproofing; at or above ground level m3 3.50 yd3 2.67
reinforced concrete fireproofing; at or above ground level m3 5.19 yd3 3.96
Working space allowance included in excavation man hours
reduce levels, basement and the like m2 0.93 ft2 0.09
pit (1 Nr or in isolation) m2 1.02 ft2 0.10
pit (more than 1 Nr) m2 1.02 ft2 0.10
trench m2 1.02 ft2 0.10
pile cap and ground beam m2 1.02 ft2 0.10
Excavate by machine
Excavate; reduce levels maximum depth n e 0.25m m3 0.34 yd3 0.26
maximum depth n e 1.00m m3 0.34 yd3 0.26
maximum depth n e 2.00m m3 0.40 yd3 0.31
maximum depth n e 4.00m m3 0.46 yd3 0.35
Excavate; basement and the like maximum depth n e 0.25m m3 0.34 yd3 0.26
maximum depth n e 1.00m m3 0.34 yd3 0.26
maximum depth n e 2.00m m3 0.40 yd3 0.31
maximum depth n e 4.00m m3 0.46 yd3 0.35
Excavate; pit (isolated) maximum depth n e 0.25m m3 0.46 yd3 0.35
maximum depth n e 1.00m m3 0.46 yd3 0.35
maximum depth n e 2.00m m3 0.57 yd3 0.44
maximum depth n e 4.00m m3 0.63 yd3 0.48
Excavate; pit (more than I Nr)) maximum depth n e 0.25m m3 0.34 yd3 0.26
maximum depth n e 1.00m m3 0.34 yd3 0.26
maximum depth n e 2.00m m3 0.40 yd3 0.31
maximum depth n e 4.00m m3 0.46 yd3 0.35
Excavate; trench n e 300mm width; maximum depth n e 0.25m m3 0.34 yd3 0.26
n e 300mm width; maximum depth n e 1.00m m3 0.34 yd3 0.26
n e 300mm width; maximum depth n e 2.00m m3 0.40 yd3 0.31
n e 300mm width; maximum depth n e 4.00m m3 0.46 yd3 0.35
over 300mm width; maximum depth n e 0.25m m3 0.34 yd3 0.26
over 300mm width; maximum depth n e 1.00m m3 0.34 yd3 0.26
over 300mm width; maximum depth n e 2.00m m3 0.40 yd3 0.31
over 300mm width; maximum depth n e 4.00m m3 0.46 yd3 0.35
Excavate; pile cap and ground beam maximum depth n e 0.25m m3 0.34 yd3 0.26
maximum depth n e 1.00m m3 0.34 yd3 0.26
maximum depth n e 2.00m m3 0.40 yd3 0.31
maximum depth n e 4.00m m3 0.46 yd3 0.35
Excavate; remove earth bund maximum depth n e 0.25m m3 0.23 yd3 0.18
maximum depth n e 1.00m m3 0.23 yd3 0.18
maximum depth n e 2.00m m3 0.29 yd3 0.22
maximum depth n e 4.00m m3 0.34 yd3 0.26
rock; m3 1.48 yd3 1.13
mass concrete; m3 1.48 yd3 1.13
reinforced concrete; m3 2.60 yd3 1.98
coated macadam or asphalt paving; m3 0.74 yd3 0.57
brickwork or blockwork; m3 1.11 yd3 0.85
concrete paving; m3 1.48 yd3 1.13
reinforced concrete paving; m3 2.60 yd3 1.98
concrete paviors 65 thick; m2 0.11 ft2 0.01
brickwork and the like generally; at or above ground level m3 1.48 yd3 1.13
reinforced concrete generally; at or above ground level m3 2.60 yd3 1.98
brickwork fireproofing; at or above ground level m3 1.48 yd3 1.13
reinforced concrete fireproofing; at or above ground level m3 2.97 yd3 2.27
Excavate; extra over for breaking out; irrespective depth of excavation
Excavate; extra over to demolish obstruction ; (removal to an agreed location on site; measured as disposal of excavated material)
Excavate; extra over for working space allowance; (disposal of any surplus excavated material to agreed location on site; backfilling with selected excavated material)
Excavate; extra over for breaking out; irrespective of depth of excavation
Excavate; extra over to demolish obstruction; (removal to an agreed location on site; measured as disposal of excavated material)
290
Working space allowance included in excavation man hours
reduce level , basement and the like m2 0.34 ft2 0.03
pit (1 Nr or in isolation) m2 0.38 ft2 0.04
pit (more than 1 Nr) m2 0.38 ft2 0.04
trench m2 0.38 ft2 0.04
pile cap and ground beam m2 0.38 ft2 0.04
Earthwork support
Support; face of excavation distance between opposing faces n e 2.00m; maximum depth n e 1.00m
m2 0.17 ft2 0.02
distance between opposing faces over 2.00 but n e 4.00m; maximum depth n e 1.00m
m2 0.19 ft2 0.02
distance between opposing faces over 4.00m; maximum depth n e 1.00m
m2 0.22 ft2 0.02
distance between opposing faces n e 2.00m; maximum depth n e 2.0m
m2 0.22 ft2 0.02
distance between opposing faces over 2.00 but n e 4.00m; maximum depth n e 2.00m
m2 0.25 ft2 0.02
distance between opposing faces over 4.00m; maximum depth n e 2.00m
m2 0.28 ft2 0.03
distance between opposing faces n e 2.00m; maximum depth n e 4.00m
m2 0.28 ft2 0.03
distance between opposing faces over 2.00 but n e 4.00m; maximum depth n e 4.00m
m2 0.31 ft2 0.03
distance between opposing faces over 4.00m; maximum depth n e 4.00m
m2 0.36 ft2 0.03
distance between opposing faces n e 2.00m; maximum depth over 4.00m depth
m2 0.31 ft2 0.03
distance between opposing faces over 2.00 but not exceeding 4.00m; maximum depth over 4.00m
m2 0.34 ft2 0.03
distance between opposing faces over 4.00m; maximum depth over 4.00m depth
m2 0.40 ft2 0.04
curved; irrespective of depth of support m2 0.14 ft2 0.01
in unstable ground; irrespective of depth of support m2 0.29 ft2 0.03
next to roadway; irrespective of depth of support m2 0.29 ft2 0.03
left in; irrespective of depth of support m2 0.00 ft2 0.00
SURFACE TREATMENT
Compacting
Compact surface face of excavation; vertical m2 0.22 ft2 0.02
face of excavation; battered m2 0.22 ft2 0.02
filling; horizontal m2 0.06 ft2 0.01
bottom of excavation; horizonral m2 0.06 ft2 0.01
Trimming
face of excavation; sloping m2 0.22 ft2 0.02
side of cutting; battered m2 0.22 ft2 0.02
side of cutting; vertical m2 0.24 ft2 0.02
side of cutting; battered; in rock m2 0.58 ft2 0.05
side of cutting; vertical; in rock m2 0.58 ft2 0.05
side of embankment; battered m2 0.22 ft2 0.02
side of embankment; vertical m2 0.24 ft2 0.02
Embankment; trimming surface; forming slope angle of slope not exceeding (n e) 15 degees (deg) m2 0.17 ft2 0.02
angle of slope over 15 but n e 30 deg m2 0.17 ft2 0.02
angle of slope over 30 but n e 45 deg m2 0.17 ft2 0.02
angle of slope over 45 but n e 60 deg m2 0.17 ft2 0.02
DISPOSAL
Removal by hand
transport to the agreed location on site; for disposal by others m3 0.18 yd3 0.14
transport to the agreed location on site; material classified by the Client as contaminated under the provision of the Poisonous Waste Act 1972; disposal by others.
m3 1.81 yd3 1.38
transport to deposit in spoil heap, for reuse as backfill material m3 0.40 yd3 0.31
Removal by machine
Remove excavated material transport to the agreed location on site; for disposal by others m3 0.18 yd3 0.14
transport to the agreed location on site; material classified by the Client as contaminated under the provision of the Poisonous Waste Act 1972; disposal by others.
m3 0.69 yd3 0.53
transport to deposit in spoil heap, for reuse as backfill material m3 0.21 yd3 0.16
yd3 0.00
Support; extra over all classes of earthwork
Working space allowance to excavation ; disposal of any surplus excavated material; remove to agreed location on site ; filling with select excavated material
Remove excavated material
Trim surface
291
Removal restriction
transport a distance over 10 but n e 25 m m3 0.11 yd3 0.08
transport a distance over 25 but n e 50 m m3 0.14 yd3 0.11
transport a distance over 50 but n e 75 m m3 0.17 yd3 0.13
transport a distance over 75 but n e 100 m m3 0.19 yd3 0.15
transport a distance over 100 m m3 0.21 yd3 0.16
transport a distance over 10 but n e 25 m m3 0.22 yd3 0.17
transport a distance over 25 but n e 50 m m3 0.40 yd3 0.30
transport a distance over 50 but n e 75 m m3 0.58 yd3 0.44
transport a distance over 75 but n e 100 m m3 0.71 yd3 0.54
transport a distance over 100 m m3 0.75 yd3 0.57
FILLING
Making up levels
Filling; make up levels; selected excavated material arising from excavation; n e 250mm thick m3 0.50 yd3 0.38
approved imported hardcore; n e 250mm thick m3 0.41 yd3 0.31
approved imported 75 down limestone; n e 250mm thick m3 0.48 yd3 0.37
imported MOT type 1 sub-base; n e 250mm thick m3 0.40 yd3 0.30
imported concreting sand to BS 882; n e 250mm thick m3 0.34 yd3 0.26
imported building sand to BS 1200; n e 250mm thick m3 0.43 yd3 0.33
Filling; make up levels; selected excavated material arising from excavation; over 250mm thick
m3 0.45 yd3 0.35
approved imported low permeability earth filling in earth bund; over 250mm thick
m3 0.31 yd3 0.24
approved imported hardcore; over 250mm thick m3 0.36 yd3 0.28
approved imported 75 down limestone; over 250mm thick m3 0.36 yd3 0.28
imported MOT type 1 sub-base; over 250mm thick m3 0.36 yd3 0.28
imported concreting sand to BS 882; over 250mm thick m3 0.39 yd3 0.30
imported building sand to BS 1200; over 250mm thick m3 0.39 yd3 0.30
imported building sand to BS1200; 50 thick under paving m2 0.02 ft2 0.00
approved imported sand filling; 100 thick m2 0.03 ft2 0.00
approved imported 20 nominal size white limestone chippings; 50 thick
m2 0.02 ft2 0.00
approved imported top soil; 150 thick m2 0.07 ft2 0.01
approved imported top soil; 150 thick sloping side of earth bund m2 0.08 ft2 0.01
Backfilling excavation
Filling; to excavation; selected excavated material arising from excavation; n e 250mm thick m3 0.50 yd3 0.38
approved imported hardcore; n e 250mm thick m3 0.41 yd3 0.31
Filling; to excavation; selected excavated material arising from excavation; over 250mm thick
m3 0.45 yd3 0.35
approved imported low permeability earth filling in earth bund; over 250mm thick
m3 0.31 yd3 0.54
SUNDRY WORK
Laying in position
Form temporary bund; sand bag filled with approved material; laid to form wall m3 1.59 yd3 1.22
Form temporary bund; railway sleepers collect from agreed location on site and lay flat in single layer m2 0.46 ft2 0.04
supply and lay flat in single layer m2 0.10 ft2 0.01
Laying mesh fabric overlay; to slope of embankment angle of slope n e 15 deg m2 0.11 ft2 0.01
angle of slope over 15 but n e 30 deg m2 0.11 ft2 0.01
angle of slope over 30 but n e 45 deg m2 0.11 ft2 0.01
angle of slope over 45 but n e 60 deg m2 0.11 ft2 0.01
membrane; lapped joint m2 0.07 ft2 0.01
membrane; in wrapping to french drain m2 0.09 ft2 0.01
angle of slope over 30 but n e 45 deg; 1.50 x 1.50m grid m2 5.00 ft2 0.47
angle of slope over 45 but n e 60 deg; 1.50 x 1.50m grid m2 5.00 ft2 0.47
angle of slope over 30 but n e 45 deg; 3.00 x 3.00m grid m2 6.50 ft2 0.60
angle of slope over 45 but n e 60 deg; 3.00 x 3.00m grid m2 6.50 ft2 0.60
Form base with; approved bitumen - sand mix; including preparing surface under
tank base bed; laid to conical falls; 50mm thick m2 0.60 ft2 0.06
tank skirt; 50mm thick m2 0.60 ft2 0.06
Removal of excavated material; extra over where access is limited to wheel barrow (Note: first 10m deemed included)
Removal of excavated material; extra over where vehicular access is restricted, using dumper (Note: first 10m deemed included).
Filling; make up levels;
Laying; geotextile membrane on earth
Lay ground anchoring system; comprising ground plate, anchor and tensioning arrangement
292
basket size 2.00 x 1.00 v 0.50m Nr 1.46 Nr 1.46
basket size 2.00 x 1.00 v 1.00m Nr 1.39 Nr 1.39
basket size 3.00 x 1.00 v 0.50m Nr 1.94 Nr 1.94
basket size 3.00 x 1.00 v 1.00m Nr 3.89 Nr 3.89
basket size 6.00 x 2.00 x 0.17m Nr 0.46 Nr 0.46
basket size 6.00 x 2.00 x 0.23m Nr 0.62 Nr 0.62
basket size 6.00 x 2.00 x 0.30m Nr 0.69 Nr 0.69
half brick wall m 0.38 ft 0.12
one brick wall m 0.51 ft 0.16
Lay mattress gabion basket; filling with broken stone, 125mm - 200mm size
Lay wire mesh gabion basket; galvanised mesh 80mm x 100mm; filling with broken stone, 125mm - 200mm size
Wedge and pin; slate in cement mortar(1:4); underside of existing foundation
Pumping out
Provide plant; assume one pump bring to site, installation, maintenance, dismantling. and removal hr 3.00 hr 3.00
hr 0.10 hr 0.10
Apply weedkiller / cut grass see roads, pavings & fencing
Pump out excavations from all ground water in accordance with the Design and Engineering Practice "Civil Engineering Workmanship General Specifications" No 2 Section 3, Clause 2.3.12.
labour attendance on mechanical pumping out of excavation, etc per hour of activity
Clean
293
Reform
Repair ground retaining mesh; damaged area angle of slope n e 15deg m2 0.15 ft2 0.01
angle of slope over 15 but n e 30 deg m2 0.15 ft2 0.01
angle of slope over 30 but n e 45 deg m2 0.15 ft2 0.01
angle of slope over 45 but n e 60 deg m2 0.15 ft2 0.01
retension wire Nr 2.00 Nr 2.00
hole in mesh; vertical; n e 0.50m2 Nr 2.25 Nr 2.25
hole in mesh; horizontal; n e 0.50m2 Nr 2.25 Nr 2.25
laid to conical falls; 50 thick; to tank skirt, including making good new to existing edge
m2 0.72 ft2 0.07
tank skirt 50 thick; in repair, including making good new to existing edges
m2 0.72 ft2 0.07
Underpinning
900mm high, one brick wall m2 11.60 ft2 1.08
900mm high, two brick wall m2 13.78 ft2 15.06
1200mm high, one brick wall m2 14.49 ft2 30.33
1200mm high, two brick wall m2 17.42 ft2 53.88
1500mm high, one brick wall m2 16.58 ft2 67.86
1500mm high, two brick wall m2 20.18 ft2 102.78
1800mm high, one brick wall m2 18.80 ft2 114.55
1800mm high, two brick wall m2 22.98 ft2 163.00
900mm high, one brick wall m2 13.64 ft2 1.27
900mm high, two brick wall m2 15.87 ft2 1.48
1200mm high, one brick wall m2 16.76 ft2 1.56
1200mm high, two brick wall m2 19.69 ft2 1.83
1500mm high, one brick wall m2 19.16 ft2 1.78
1500mm high, two brick wall m2 22.67 ft2 2.11
1800mm high, one brick wall m2 21.38 ft2 1.99
1800mm high, two brick wall m2 25.73 ft2 2.39
900mm high, one brick wall m2 16.04 ft2 1.49
900mm high, two brick wall m2 18.31 ft2 1.70
1200mm high, one brick wall m2 19.38 ft2 1.80
1200mm high, two brick wall m2 22.36 ft2 2.08
1500mm high, one brick wall m2 21.96 ft2 2.04
1500mm high, two brick wall m2 25.47 ft2 2.37
1800mm high, one brick wall m2 24.58 ft2 2.29
1800mm high, two brick wall m2 28.67 ft2 2.67
900mm high, one brick wall m2 17.56 ft2 1.63
900mm high, two brick wall m2 19.69 ft2 1.83
1200mm high, one brick wall m2 20.76 ft2 1.93
1200mm high, two brick wall m2 23.73 ft2 2.21
1500mm high, one brick wall m2 23.33 ft2 2.17
1500mm high, two brick wall m2 26.84 ft2 2.50
1800mm high, one brick wall m2 26.00 ft2 2.42
1800mm high, two brick wall m2 30.09 ft2 2.80
Locating
Locate and repair; leak in water main; existing service and the like
maximum depth n e 0.25m m3 1.77 yd3 1.35
maximum depth n e 1.00m m3 1.82 yd3 1.39
maximum depth n e 2.00m m3 2.10 yd3 1.60
maximum depth n e 4.00m m3 2.21 yd3 1.69
In stages n.e. 1500mm long from one side of existin g wall and foundation, excavate preliminary trench by machine and underpinning pit by hand, partial backfill, partial disposal, earthwork support cutting away projectin g foundation , prepare underside of existing, compact base of pit, plain insitu concrete, formwork, engineering brick work, pitch polymer damp proof course, wedge and pin to undersi de of existing with slate
Excavate; starting at 4.00m below ground level
Repair ground anchor plate, wire and tensioning arrangement;
Repair
Excavate; starting at 3.00m below ground level
Repair base with; approved bitumen - sand mix; including preparing surface under
Excavate; starting at 1.00m below ground level
Excavate; starting at 2.00m below ground level
Repair gabion basket; provide temporary support; reform or weld mesh to make good; refill with approved material
294
Removal of existing retaining structures only. For replacement use NEW rates
Removing
Take up and remove; temporary bund wall transport to agreed location on site; for disposal by others m3 0.79 yd3 0.60
Take up and remove; railway sleepers take up single layer laid flat and transport to agreed location on site; for disposal by others
m2 0.33 ft2 0.03
laid to angle of slope n e 15 deg m2 0.19 ft2 0.02
laid to angle of slope over 15 but n e 30 deg m2 0.19 ft2 0.02
laid to angle of slope over 30 but n e 45 deg m2 0.19 ft2 0.02
laid to angle of slope over 45 but n e 60 deg m2 0.19 ft2 0.02
angle of slope over 30 but n e 45 deg m2 1.50 ft2 0.14
angle of slope over 45 but n e 60 deg m2 1.50 ft2 0.14
angle of slope over 30 but n e 45 deg m2 1.60 ft2 0.15
angle of slope over 45 but n e 60 deg m2 1.60 ft2 0.15
basket size 2.00 x 1.00 v 0.50m nr 1.46 nr 1.46
basket size 2.00 x 1.00 v 1.00m nr 1.39 nr 1.39
basket size 3.00 x 1.00 v 0.50m nr 1.94 nr 1.94
basket size 3.00 x 1.00 v 1.00m nr 3.89 nr 3.89
basket size 6.00 x 2.00 x 0.17m nr 0.46 nr 0.46
basket size 6.00 x 2.00 x 0.23m nr 0.62 nr 0.62
basket size 6.00 x 2.00 x 0.30m nr 0.69 nr 0.69
Remove material; precast concrete crib retaining wall infill m3 1.75 yd3 1.34
Dismantle and remove existing gabion basket retaining wall
Dismantle and remove existing mattrass gabion basket retaining wall
Remove existing ground anchor, plate and tensioning arrangement to 3.0 x 3.0m grid
Remove existing ground anchor, plate and tensioning arrangement to 1.5 x 1.5m grid
Replace
Take up and remove existing mesh fabric overlay to embankment
295
Q.2.1.2 Piling
PILING
FOUNDATION PILING
Boring
Item 30.00 Item 30.00
450mm diameter; reinforced; 10m long Nr 17.75 Nr 17.75
add up to 15m long; per m m 1.78 ft 0.54
deduct for length less than 10m; per m m -1.78 ft -0.54
530mm diameter; reinforced; 10m long Nr 19.75 Nr 19.75
add up to 15m long; per m m 2.25 ft 0.69
deduct for length less than 10m; per m m -2.25 ft -0.69
600mm diameter; reinforced; 10m long Nr 22.25 Nr 22.25
add up to 15m long m 2.22 ft 0.68
deduct for length less than 10m; per m m -2.22 ft -0.68
Item 30.00 Item 30.00
450mm diameter; reinforced; 10m long Nr 11.75 Nr 11.75
add up to 15m long; per m m 1.18 ft 0.36
deduct for length less than 10m; per m m -1.18 ft -0.36
530mm diameter; reinforced; 10m long Nr 13.25 Nr 13.25
add up to 15m long; per m m 1.23 ft 0.38
deduct for length less than 10m; per m m -1.23 ft -0.38
600mm diameter; reinforced; 10m long Nr 15.78 Nr 15.78
add up to 15m long; per m m 1.58 ft 0.48
deduct for length less than 10m; per m m -1.58 ft -0.48
Testing
using pile as tension; first pile Nr 4.00 Nr 4.00
using pile as tension; subsequent pile Nr 2.50 Nr 2.50
Disposal of arising from piling excavation see Groundworks
Labour on foundation pile
450 diameter pile; n e 500 long Nr 1.17 Nr 1.17
450 diameter pile ; over 500 but n e 1m Nr 1.75 Nr 1.75
530 diameter pile; n e 500 long Nr 1.46 Nr 1.46
530 diameter pile; over 500 but n e 1m Nr 2.04 Nr 2.04
600 diameter pile; n e 500 long Nr 1.75 Nr 1.75
600 diameter pile; over 500 but n e 1m Nr 2.33 Nr 2.33
450 diameter pile head Nr 1.17 Nr 1.17
530 diameter pile head Nr 1.46 Nr 1.46
600 diameter pile head Nr 1.75 Nr 1.75
Information on driven foundation piling not provide d
SHEET PILING
Driving
Provide all plant; driving sheet piling; assume one rig bring to site, erection, maintenance, dismantling and removal. Item 30.00 Item 30.00
weight 99.10kg/m2 m2 1.25 ft2 0.12
weight 112.30kg/m2 m2 1.35 ft2 0.13
weight 137.10kg/m2 m2 1.45 ft2 0.13
weight 170.80kg/m2 m2 1.65 ft2 0.15
weight 236.90kg/m2 m2 1.95 ft2 0.18
Labour on sheet piling
Burn off top sheet piling m 0.80 ft 0.24
horizontal m 0.45 ft 0.14
raking m 0.45 ft 0.14
Cut; burning sheet piling
UnitPILING
Install; tripod bored pile; cast in place concrete up to 20.00 N/mm2
Provide all plant; tripod bored;
Unit
Provide all plant; rotary bored;
Install; rotary bored pile; cast in place concrete up to 20.00 N/mm2
Cut off top
Prepare top; exposing reinforcement for pile cap
Test; working to 600 kN/t
New Work
Labour Norm Hrs.
Labour Norm Hrs.
bring to site, erection, maintenance, dismantling at each pile position for 100 Nr piles and removal
bring to site, erection, maintenance, dismantling at each pile position for 100 Nr piles and removal
Drive steel sheet pile
296
Not applicable
Clean
Clean down, remove loose material, prepare and apply approved surface treatment
sheet metal piling, vertical; corrugated m2 0.75 ft2 0.07
Note. After integretary test any broken piles discovered and caused by contractor to be replaced at no cost
Repair
Removal only; replacement as New Rates
Removing
Provide all plant; driven sheet piling; assume one rig bring to site, erection, maintenance, dismantling and removal. Item 30.00
weight 99.10kg/m2 m 0.85 ft 0.26
weight 112.30kg/m2 m 0.85 ft 0.26
weight 137.10kg/m2 m 0.85 ft 0.26
weight 170.80kg/m2 m 0.85 ft 0.26
weight 236.90kg/m2 m 0.90 ft 0.27
Remove / extract damaged or defective sheet piling, provide temporary support to exposed material
Replace
297
Q.2.1.3 Concrete Work
CONCRETE FOUNDATION
Insitu concretePlain;
mass concrete in making up level m3 0.70 yd3 0.53
blinding bed laid on earth ; n e 150 thick m3 0.76 yd3 0.58
foundation; n e 150 thick m3 0.51 yd3 0.39
foundation ; over 150 but n e 450 thick m3 0.51 yd3 0.39
foundation ; over 450 m3 0.50 yd3 0.38
isolated foundation n e 150 thick m3 0.53 yd3 0.40
isolated foundation ; over 150 but n e 450 thick m3 0.52 yd3 0.40
isolated foundation ; over 450 m3 0.51 yd3 0.39
bed; n e 150 thick m3 0.51 yd3 0.39
bed; over 150 but n e 450 thick m3 0.51 yd3 0.39
bed ; over 450 m3 0.50 yd3 0.38
sloping n e 15 degrees m3 0.11 yd3 0.08
sloping over 15 degrees m3 0.13 yd3 0.10
on or against earth or unblinded hardcore m3 0.21 yd3 0.16
Reinforced
foundation; n e 150mm thick m3 1.05 yd3 0.80
foundation; over 150 but n e 450mm thick m3 1.05 yd3 0.80
foundation; over 450mm thick m3 1.05 yd3 0.80
ground beam; n e 150mm thick m3 1.13 yd3 0.86
ground beam; over 150 but n e 450mm thick m3 1.13 yd3 0.86
ground beam; over 450mm thick m3 1.13 yd3 0.86
isolated foundation; n e 150mm thick m3 1.14 yd3 0.87
isolated foundation; over 150 but n e 450mm thick m3 1.14 yd3 0.87
isolated foundation; over 450mm thick m3 1.14 yd3 0.87
machine base; n e 0.5m3; ne 150mm thick m3 1.24 yd3 0.94
machine base; n e 0.5m3; over 150 but n e 450mm thick m3 1.24 yd3 0.94
machine base;n e 0.5m3; over 450mm thick m3 1.24 yd3 0.94
bed; n e 150mm thick m3 1.10 yd3 0.84
bed; over 150 but n e 450mm thick m3 1.07 yd3 0.82
bed; over 450mm thick m3 1.02 yd3 0.78
bed to manhole, duct and the like; n e 150mm thick m3 1.17 yd3 0.89
bed to manhole, duct and the like; over 150mm but n e 450mm thick m3 1.14 yd3 0.87
bed to manhole, duct and the like; over 450mm thick m3 1.08 yd3 0.82
Lay; pour concrete; extra over irrespective of grade or use;
sloping n e 15 degrees; m3 0.18 yd3 0.14
sloping over 15 degrees; m3 0.20 yd3 0.15
on or against unblinded hardcore; m3 0.24 yd3 0.19
600m thick wall m2 3.75 ft2 0.35
1000m thick wall m2 5.00 ft2 0.47
CONCRETE STRUCTURE
Reinforced
slab; n e 150mm thick m3 2.64 yd3 2.02
slab; over 150mm but n e 450mm thick m3 1.27 yd3 0.97
slab; over 450mm thick m3 1.20 yd3 0.92
coffered and troughed slab; n e 150mm thick m3 2.71 yd3 2.07
coffered and troughed slab; over 150 but n e 450mm thick m3 1.30 yd3 0.99
coffered and troughed slab; over 450mm thick m3 1.23 yd3 0.94
Lay; pour concrete; grade C40 to BS 8110 table 3.4
CONCRETE WORK Unit Unit Labour Norm Hrs.
1,750.00Item
Lay; pour concrete; grade C40 to BS 8110 table 3.4
Construct; embedded diaphragm retaining wall; contiguous panel construction; panel lengths not exceeding 5m;
1,750.00
Lay; pour concrete; grade C20 to BS 8110 table 6.2
Lay; pour concrete; Grade C40 to BS 8110 table 6.2
Lay; pour concrete; extra over irrespective of grade or use; pour
bring to site, erection, maintenance, dismantling assumed for 1000m2 walling and removal
Provide all plant; storage and recyling of bentonite slurry; excavation; insitu or ready mix concrete piling
New Work
Labour Norm Hrs.
Item
298
Lay; pour concrete; extra over irrespective of grade or use;
sloping n e 15 degrees; m3 0.12 yd3 0.09
sloping over 15 degrees; m3 0.18 yd3 0.14
wall; n e 150mm thick m3 4.25 yd3 3.24
wall; over 150 but n e 450mm thick m3 3.99 yd3 3.05
wall; over 450mm thick m3 3.73 yd3 2.85
filling to hollow wall; n e 150mm thick m3 1.58 yd3 1.21
filling to hollow wall; over 150 but n e 450mm thick m3 1.35 yd3 1.03
filling to hollow wall; over 450mm thick m3 1.23 yd3 0.94
isolated beam; n e 150mm thick m3 1.43 yd3 1.09
isolated beam; over 150 but n e 450mm thick m3 1.43 yd3 1.09
isolated beam; over 450mm thick m3 1.43 yd3 1.09
attached beam; n e 150mm thick m3 1.35 yd3 1.03
attached beam; over 150 but n e 450mm thick m3 1.35 yd3 1.03
attached beam; over 450mm thick m3 1.35 yd3 1.03
isolated; beam casing m3 2.86 yd3 2.18
beam casing m3 2.70 yd3 2.06
attached; beam casing m3 2.70 yd3 2.06
isolated; column casing m3 2.85 yd3 2.18
column casing m3 3.01 yd3 2.30
staircase m3 2.55 yd3 1.95
upstand m3 2.55 yd3 1.95
over 5m but n e 10 m above ground level m3 0.42 yd3 0.32
over 10m but n e 20 m above ground level m3 0.64 yd3 0.49
over 20 m above ground level m3 0.86 yd3 0.66
Labour to concrete work
quantity less than 5m3 m3 3.94 yd3 3.01
quantity over 5 but n e 10 m3 m3 1.97 yd3 1.51
quantity over 10 m3 m3 1.31 yd3 1.00
over 2.00 but n e 4.00 m high m3 0.88 yd3 0.68
over 4.00 but n e 6.00 m high m3 1.33 yd3 1.01
over 6.00 but n e 8.00 m high m3 1.77 yd3 1.35
Treat surface of unset concrete tamping m2 0.04 ft2 0.00
power floating m2 0.09 ft2 0.01
trowelling m2 0.09 ft2 0.01
floated finish m2 0.09 ft2 0.01
trowelled and brushed finish m2 0.13 ft2 0.01
Extra over treated surface for applying red pigment m2 0.07 ft2 0.01
Precast concrete unit
floor spans up to 3.00m; 1200 x 150mm m2 1.59 ft2 0.15floor spans over 3.00 but n e 6.00m; 1200 x 150mm m2 1.62 ft2 0.15
floor spans over 6.00 but n e 7.50m; 1200 x 200mm m2 1.67 ft2 0.16
floor spans over 7.50 but n e 9.50m; 1200 x 250mm m2 1.89 ft2 0.18
floor spans over 9.50 but n e 12.00m; 1200 x 300mm m2 2.00 ft2 0.19
floor spans over 12.00 but n e 13.00m; 1200 x 350mm m2 2.09 ft2 0.19
floor spans over 13.00 but n e 14.00m; 1200 x 400mm m2 2.29 ft2 0.21
floor spans over 14.00 but n e 15.00m; 1200 x 450mm m2 2.33 ft2 0.22
height n e 1.00m m2 2.25 ft2 0.21
height over 1.00m but n.e. 2.00m m2 2.35 ft2 0.22
height over 2.00m but n.e. 3.00m m2 2.45 ft2 0.23
height over 3.00m but n.e. 4.00m m2 2.55 ft2 0.24
height over 4.00m but n.e. 5.00m m2 2.65 ft2 0.25
height over 5.00m but n.e. 6.00m m2 2.75 ft2 0.26
Seal and joint; approved material; between precast concrete unit
vertical m 0.08 ft 0.02
125mm thick; height n e 1.00m m2 0.50 ft2 0.05
125mm thick, height over 1.00m but n.e. 2.00m m2 0.55 ft2 0.05
125mm thick; height over 2.00m but n.e. 3.00m m2 0.60 ft2 0.06
125mm thick; height over 3.00m but n.e. 4.00m m2 0.65 ft2 0.06
125mm thick; height over 4.00m but n.e. 5.00m m2 0.70 ft2 0.07
125mm thick; height over 5.00m but n.e. 6.00m m2 0.75 ft2 0.07
Lay; pour concrete; extra over irrespective of grade or use; pumping
Install; retaining wall unit; lifting unit into position
Install; cribwall; precast unit doweless system; dry joint; filled by machine with crushed rock (excavation and foundation not included);
Lay; pour concrete; extra over irrespective of grade or use; hoisting material beyond the first 2.00 m above ground level
Install; prestressed precast concrete structural suspended floor; fixed on hard level bearings
Lay; pour concrete; extra over irrespective of grade or use; place at height
299
Install; lintel; bedded and pointed in cement mortar (1:6) 100 x 150 rectangular; two 12mm mild steel bars; m 0.36 ft 0.11
225 x 150 rectangular; two 12mm mild steel bars; m 0.63 ft 0.19
225 x 225 rectangular; two 12 mm mild steel bars; m 0.93 ft 0.28
250 x 225 boot; two 12 mm mild steel bars; m 1.11 ft 0.34
275 x 225 boot; two 12 mm mild steel bars; m 0.90 ft 0.27
152 x 76mm rectangular; m 0.20 ft 0.06
178 x 64mm rectangular; m 0.20 ft 0.06
305 x 76mm rectangular; m 0.29 ft 0.09
extra over for fair end nr 0.25 nr 0.25
extra over for angle nr 0.36 nr 0.36
300 x 100 x 75mm rectangular nr 0.23 nr 0.23
225 x 225 x 150mm rectangular nr 0.37 nr 0.37
450 x 450 x 150mm rectangular nr 0.89 nr 0.89
standard size 600mm wide; length n e 1000mm nr 3.88 nr 3.88
standard size 600mm wide; length over 1000mm m 3.88 ft 1.18
sleeper of other size m3 15.77 yd3 12.04
Install; cover slab; placing over opening 75mm thick cast in suitable length and width; m2 1.43 ft2 0.13
150mm thick cast in suitable length and width; m2 2.34 ft2 0.22
Formwork; to concrete foundation or structure
Erect formwork and remove; vertical side of foundation; over 1.00m high m2 0.95 ft2 0.09
side of foundation; n e 250mm high m 0.29 ft 0.09
side of foundation; over 250 but n e 500mm high m 0.52 ft 0.16
side of foundation; over 500 but n e 1.00m high m 0.95 ft 0.29
side of ground beam; edge of bed; over 1.00m high m2 0.95 ft2 0.09
side of ground beam; edge of bed; n e 250mm high m 0.29 ft 0.09
side of ground beam; edge of bed; over 250 but ne 500mm high m 0.52 ft 0.16
side of ground beam; edge of bed; over 500 but n e 1.00m high m 0.95 ft 0.29
edge of suspended slab; over 1.00m high m2 1.07 ft2 0.10
edge of suspended slab; n e 250mm high m 0.32 ft 0.10
edge of suspended slab; over 250 but n e 500mm high m 0.59 ft 0.18
edge of suspended slab; over 500 but n e 1.00m high m 1.07 ft 0.33
side of upstand; over 1.00m high m2 1.07 ft2 0.10
side of upstand; n e 250mm high m 0.32 ft 0.10
side of upstand; over 250 but n e 500mm high m 0.59 ft 0.18
side of upstand; over 500 but n e 1.00m high m 1.07 ft 0.33
step in top surface; over 1.00m high m2 1.19 ft2 0.11
step in top surface; n e 250mm high m 0.36 ft 0.11
step in top surface; over 250 but n e 500mm high m 0.65 ft 0.20
step in top surface; over 500 but n e 1000mm high m 1.19 ft 0.36
step in soffit; over 1.00m high m2 1.43 ft2 0.13
step in soffit; n e 250mm high m 0.43 ft 0.13
step in soffit; over 250 but n e 500mm high m 0.81 ft 0.25
step in soffit; over 500 but 100m high m 1.43 ft 0.44
machine base and plinth; over 1.00m high m2 1.17 ft2 0.11
machine base and plinth; n e 250mm high m 0.35 ft 0.11
machine base and plinth; over 250 but n e 500mm high m 0.64 ft 0.20
machine base and plinth; over 500 but n e 1.00m high m 1.17 ft 0.36
extra over for formwork left in; over 1.00m high m2 -0.15 ft2 -0.01
extra over for formwork left in; n e 250mm high m -0.15 ft -0.05
extra over for formwork left in; over 250mm but n e 500mm high m -0.15 ft -0.05
extra over for formwork left in; over 500mm but n e 1.00m high m -0.15 ft -0.05
Install; padstone; bedded and pointed in cement mortar (1:6)
Install; coping; bedded and pointed in cement mortar (1:6)
Install; pipe support; (excluding groundwork and blinding)
300
slab n e 200mm thick; n e 1.50m to soffit m2 0.83 ft2 0.08
slab n e 200mm thick; 1.50m to 3.00m to soffit m2 0.97 ft2 0.09
slab n e 200mm thick; 3.00m to 4.50m to soffit; m2 1.11 ft2 0.10
slab n e 200mm thick; 4.50m to 6.00m to soffit; m2 1.11 ft2 0.10
slab over 200 but n e 300 thick; n e 1.50m high to soffit; m2 0.83 ft2 0.08
slab over 200 but n e 300 thick; 1.50m to 3.00m high to soffit; m2 0.97 ft2 0.09
slab over 200 but n e 300 thick; 3.00m to 4.50m high to soffit; m2 1.11 ft2 0.10
slab over 200 but n e 300 thick; 4.50m to 6.00m high to soffit; m2 1.11 ft2 0.10
percentage adjustment; each additional 1.50m lift % % 0.00
slab n e 200mm thick; n e 1.50m to soffit m2 0.92 ft2 0.09
slab n e 200mm thick; 1.50m to 3.00m to soffit m2 1.06 ft2 0.10
slab n e 200mm thick; 3.00m to 4.50m to soffit; m2 1.19 ft2 0.11
slab n e 200mm thick; 4.50m to 6.00m to soffit; m2 1.19 ft2 0.11
slab over 200 but n e 300 thick; n e 1.50m high to soffit; m2 0.92 ft2 0.09
slab over 200 but n e 300 thick; 1.50m to 3.00m high to soffit; m2 1.06 ft2 0.10
slab over 200 but n e 300 thick; 3.00m to 4.50m high to soffit; m2 1.19 ft2 0.11
slab over 200 but n e 300 thick; 4.50m to 6.00m high to soffit; m2 1.19 ft2 0.11
percentage adjustment; each additional 1.50m lift % % 0.00
slab n e 200mm thick; n e 1.50m to soffit m2 0.96 ft2 0.09
slab n e 200mm thick; 1.50m to 3.00m to soffit m2 1.09 ft2 0.10
slab n e 200mm thick; 3.00m to 4.50m to soffit; m2 1.22 ft2 0.11
slab n e 200mm thick; 4.50m to 6.00m to soffit; m2 1.22 ft2 0.11
slab over 200 but n e 300 thick; n e 1.50m high to soffit; m2 0.96 ft2 0.09
slab over 200 but n e 300 thick; 1.50m to 3.00m high to soffit; m2 1.09 ft2 0.10
slab over 200 but n e 300 thick; 3.00m to 4.50m high to soffit; m2 1.22 ft2 0.11
slab over 200 but n e 300 thick; 4.50m to 6.00m high to soffit; m2 1.22 ft2 0.11
percentage adjustment; each additional 1.50m lift % % 0.00
Erect formwork and remove; sloping n e 15 degrees top of structure n e 200mm thick m2 0.96 ft2 0.09
top of structure over 200 but n e 300mm thick m2 1.11 ft2 0.10
Erect formwork and remove; sloping over 15 degrees top of structure n e 200mm thick m2 0.96 ft2 0.09
top of structure over 200 but n e 300mm thick m2 1.11 ft2 0.10
Erect formwork and remove; vertical wall n e 200mm thick m2 0.80 ft2 0.07
wall n e 200mm thick; over 3m above floor level m2 0.96 ft2 0.09
wall n e 200mm thick; interrupted m2 0.91 ft2 0.08
wall n e 200mm thick; battered m2 1.08 ft2 0.10
wall over 200 but n e 300mm thick m2 1.12 ft2 0.10
wall over 200 but n e 300mm thick; over 3m above floor level m2 1.28 ft2 0.12
wall over 200 but n e 300mm thick; interrupted m2 1.40 ft2 0.13
wall over 200 but n e 300mm thick; battered m2 1.58 ft2 0.15
beam attached to slab n e 600mm girth m 0.70 ft 0.21
beam attached to slab; over 600 but n e 900mm girth m 1.00 ft 0.30
beam attached to slab; over 900 but n e 1200mm girth m 1.27 ft 0.39
beam attached to slab; over 1200 but ne 1500mm girth m 1.41 ft 0.43
beam attached to slab; over 1500 but n e 1800mm girth m 1.15 ft 0.35
beam attached to slab; over 1800 but ne 2100 girth m 1.27 ft 0.39
ft2 0.00
beam attached to wall n e 600mm girth m 0.68 ft 0.21
beam attached to wall; over 600 but n e 900mm girth m 1.00 ft 0.30
beam attached to wall ; over 900 but n e 1200mm girth m 1.27 ft 0.39
beam attached to wall; over 1200 but n e 1500mm girth m 1.41 ft 0.43
beam attached to wall; over 1500 but n e 1800mm girth m 1.15 ft 0.35
beam attached to wall; over 1800 but n e 2100mm girth m 1.27 ft 0.39
isolated beam; n e 600mm girth m 0.70 ft 0.21
isolated beam ; over 600 but 900mm girth m 1.00 ft 0.30
isolated beam ; over 900 but n e 1200mm girth m 1.27 ft 0.39
isolated beam; over 1200 but n e 1500mm girth m 1.41 ft 0.43
isolated beam; over 1500 but n e 1800mm girth m 1.15 ft 0.35
isolated beam; over 1800 but n e 2100mm girth m 1.27 ft 0.39
Erect formwork and remove; horizontal
Erect formwork and remove; sloping n e 15 degrees
Erect formwork and remove; sloping over 15 degrees from horizontal
Erect formwork and remove; horizontal and vertical; square or rectangular in section
301
beam casing attached to slab n e 600mm girth m 0.70 ft 0.21
beam casing attached to slab over 600 but n e 900mm girth m 1.00 ft 0.30
beam casing attached to slab over 900 but n e 1200mm girth m 1.27 ft 0.39
beam casing attached to slab over 1200 but n e 1500mm girth m 1.41 ft 0.43
beam casing attached to slab over 1500 but n e 1800mm girth m 1.15 ft 0.35
beam casing attached to slab over 1800 but n e 2100mm girth m 1.27 ft 0.39
beam casing attached to wall n e 600mm girth m 0.70 ft 0.21
beam casing attached to wall; over 600 but n e 900mm girth m 1.00 ft 0.30
beam casing attached to wall; over 900 but n e 1200mm girth m 1.27 ft 0.39
beam casing attached to wall; over 1200 but n e 1500mm girth m 1.41 ft 0.43
beam casing attached to wall; over 1500 but n e 1800mm girth m 1.15 ft 0.35
beam casing attached to wall; over 1800 but n e 2100mm girth m 1.27 ft 0.39
isolated beam casing n e 600mm girth m 0.70 ft 0.21
isolated beam casing over 600 but n e 900mm girth m 1.00 ft 0.30
isolated beam casing over 900 but n e 1200mm girth m 1.27 ft 0.39
isolated beam casing over 1200 but n e 1500mm girth m 1.41 ft 0.43
isolated beam casing over 1500 but n e 1800mm girth m 1.15 ft 0.35
isolated beam casing over 1800 but n e 2100mm girth m 1.27 ft 0.39
column attached to wall n e 600mm girth m 0.70 ft 0.21
column attached to wall over 600 but n e 900mm girth m 1.00 ft 0.30
column attached to wall over 900 but n e 1200mm girth m 1.27 ft 0.39
column attached to wall over 1200 but n e 1500mm girth m 1.41 ft 0.43
column attached to wall over 1500 but n e 1800mm girth m 1.15 ft 0.35
column attached to wall over 1800 but n e 2100mm girth m 1.27 ft 0.39
isolated column n e 600mm girth m 0.70 ft 0.21
isolated column over 600 but n e 900mm girth m 1.00 ft 0.30
isolated column over 900 but n e 1200mm girth m 1.27 ft 0.39
isolated column over 1200 but n e 1500mm girth m 1.41 ft 0.43
isolated column over 1500 but n e 1800mm girth m 1.15 ft 0.35
isolated column over 1800 but n e 2100mm girth m 1.27 ft 0.39
column casing attached to wall n e 600mm girth m 0.70 ft 0.21
column casing attached to wall over 600 but n e 900mm girth m 1.00 ft 0.30
column casing attached to wall over 900 but n e 1200mm girth m 1.27 ft 0.39
column casing attached to wall over 1200 but n e 1500mm girth m 1.41 ft 0.43
column casing attached to wall over 1500 but n e 1800mm girth m 1.15 ft 0.35
column casing attached to wall over 1800 but n e 2100mm girth m 1.27 ft 0.39
isolated column casing n e 600mm girth m 0.70 ft 0.21
isolated column casing over 600 but n e 900mm girth m 1.00 ft 0.30
Isolated column casing over 900 but n e 1200mm girth m 1.27 ft 0.39
isolated column casing over 1200 but n e 1500mm girth m 1.41 ft 0.43
isolated column casing over 1500 but n e 1800mm girth m 1.15 ft 0.35
isolated column casing over 1800 but n e 2100mm girth m 1.27 ft 0.39
sectional area n e 0.003m2 m 0.12 ft 0.04
sectional area over 0.003 but n e 0.01m2 m 0.12 ft 0.04
sectional area over 0.01 but n e 0.025m2 m 0.13 ft 0.04
sectional area over 0.025m2 m 0.16 ft 0.05
sectional area n e 0.003m2 m 0.12 ft 0.04
sectional area over 0.003 but n e 0.01m2 m 0.12 ft 0.04
sectional area over 0.01 but n e 0.025m2 m 0.13 ft 0.04
sectional area over 0.025m2 m 0.16 ft 0.05
sectional area n e 0.003m2 m 0.12 ft 0.04
sectional area over 0.003 but n e 0.01m2 m 0.12 ft 0.04
sectional area over 0.01 but n e 0.025m2 m 0.13 ft 0.04
sectional area over 0.025m2 m 0.16 ft 0.05
wall n e 250mm thick; n e 500 girth Nr 0.22 Nr 0.22
wall n e 250mm thick; over 500 but n e 1.00m girth Nr 0.26 Nr 0.26
wall n e 250mm thick; over 1.00 but n e 2.00m girth Nr 0.38 Nr 0.38
wall n e 250mm thick; over 2.00 but n e 3.00 m girth Nr 0.42 Nr 0.42
wall over 250 but n e 500mm thick; n e 500 girth Nr 0.33 Nr 0.33
wall over 250 but n e 500mm thick; over 500 but n e 1.00m girth Nr 0.37 Nr 0.37
wall over 250 but n e 500mm thick; over 1.00 but n e 2.00m girth Nr 0.49 Nr 0.49
wall over 250 but n e 500mm thick; over 2.00 but n e 3.00m girth Nr 0.53 Nr 0.53
Erect formwork and remove; horizontal or vertical; recess; square or rectangular in section
Erect formwork and remove; horizontal or vertical; nib; square or rectangular in section
Erect formwork and remove; vertical opening; square or rectangular
Erect formwork and remove; horizontal or vertical; rebate; square or rectangular in section
302
wall over 500 but n e 1000mm thick; n e 500 girth Nr 0.44 Nr 0.44
wall over 500 but n e 1000mm thick; over 500 but n e 1.00m girth Nr 0.47 Nr 0.47
wall over 500 but n e 1000mm thick; over 1.00 but n e 2.00m girth Nr 0.60 Nr 0.60
wall over 500 but n e 1000mm thick; over 2.00 but n e 3.00m girth Nr 0.71 Nr 0.71
slab n e 250 thick; n e 500 girth Nr 0.17 Nr 0.17
slab n e 250mm thick; over 500 but n e 1.00m girth Nr 0.19 Nr 0.19
slab n e 250mm thick; over 1.00 but n e 2.00m girth Nr 0.29 Nr 0.29
slab n e 250mm thick; over 2.00 but n e 3.00m girth Nr 0.31 Nr 0.31
slab n e 250mm thick; over 3.00 but n e 4.00m girth Nr 0.36 Nr 0.36
slab n e 250mm thick; over 4.00 but n e 5.00 m girth Nr 0.40 Nr 0.40
slab over 250 but n e 500mm thick; n e 500 girth Nr 0.25 Nr 0.25
slab over 250 but n e 500mm thick; over 500 but n e 1.00m girth Nr 0.38 Nr 0.38
slab over 250 but n e 500mm thick; over 1.00 but n e 2.00m girth Nr 0.37 Nr 0.37
slab over 250 but n e 500mm thick; over 2.00 but n e 3.00m girth Nr 0.39 Nr 0.39
slab over 250 but n e 500mm thick; over 3.00 but n e 4.00m girth Nr 0.45 Nr 0.45
slab over 250 but n e 500mm thick; over 4.00 but n e 5.00 m girth Nr 0.50 Nr 0.50
slab over 500 but n e 1000mm thick; n e 500 girth Nr 0.33 Nr 0.33
slab over 500 but n e 1000mm thick; over 500 but n e 1.00m girth Nr 0.36 Nr 0.36
slab over 500 but n e 1000mm thick; over 1.00 but n e 2.00m girth Nr 0.45 Nr 0.45
slab over 500 but n e 1000mm thick; over 2.00 but n e 3.00m girth Nr 0.66 Nr 0.66
slab over 500 but n e 1000mm thick; over 3.00 but n e 4.00m girth Nr 0.55 Nr 0.55
slab over 500 but n e 1000mm thick; over 4.00 but n e 5.00 m girth Nr 0.60 Nr 0.60
Reinforcement
straight t 19.78 t 17.95
bent t 19.78 t 17.95
curved t 19.78 t 17.95
link t 19.78 t 17.95
saving per tonne of mild steel t 0.17 t 0.15
extra over for bar; length 12.00 - 15.00 m t 0.68 t 0.61
extra over for bar; length 15.00 - 18.00 m t 0.91 t 0.83
straight t 19.78 t 17.95
bent t 19.78 t 17.95
curved t 19.78 t 17.95
link t 19.78 t 17.95
saving per tonne of mild steel t 0.00 t 0.00
extra over for bar; length 12.00 - 15.00 m t 0.00 t 0.00
extra over for bar; length 15.00 - 18.00 m t 0.00 t 0.00
straight t 19.78 t 17.95
bent t 19.78 t 17.95
curved t 19.78 t 17.95
link t 19.78 t 17.95
saving per tonne of mild steel t 0.00 t 0.00
extra over for bar; length 12.00 - 15.00 m t 0.00 t 0.00
extra over for bar; length 15.00 - 18.00 m t 0.00 t 0.00
straight t 20.76 t 18.84
bent t 20.76 t 18.84
curved t 20.76 t 18.84
link t 20.76 t 18.84
saving per tonne of mild steel t 0.00 t 0.00
extra over for bar; length 12.00 - 15.00 m t 0.00 t 0.00
extra over for bar; length 15.00 - 18.00 m t 0.00 t 0.00
straight t 20.76 t 18.84
bent t 20.76 t 18.84
curved t 20.76 t 18.84
link t 20.76 t 18.84
saving per tonne of mild steel t 0.00 t 0.00
extra over for bar; length 12.00 - 15.00 m t 0.00 t 0.00
extra over for bar; length 15.00 - 18.00 m t 0.00 t 0.00
Install reinforcement; high tensile; in any location: bar - 20mm dia
Install reinforcement; high tensile; in any location: bar - 16mm dia
Install reinforcement; high tensile; in any location: bar - 12mm dia
Erect formwork and remove; horizontal opening; square or rectangular
Install reinforcement; high tensile; in any location: bar - 25mm dia
Install reinforcement; high tensile; in any location: bar - 32mm dia
303
straight t 20.76 t 18.84
bent t 20.76 t 18.84
curved t 20.76 t 39.59
link t 20.76 t 18.84
saving per tonne of mild steel t 0.00 t 0.00
extra over for bar; length 12.00 - 15.00 m t 0.00 t 0.00
extra over for bar; length 15.00 - 18.00 m t 0.00 t 0.00
straight t 22.75 t 20.64
bent t 22.75 t 43.40
curved t 22.75 t 66.15
link t 22.75 t 20.64
saving per tonne of mild steel t 0.00 t 0.00
straight t 23.73 t 21.53
bent t 23.73 t 21.53
curved t 23.73 t 21.53
link t 23.73 t 21.53
saving per tonne of mild steel t 0.00 t 0.00
Install reinforcement; Fabric - A142 bed; horizontal m2 0.07 ft2 0.01
wall; vertical m2 0.07 ft2 0.01
Install reinforcement; Fabric - A193 bed; horizontal m2 0.08 ft2 0.01
wall; vertical m2 0.08 ft2 0.01
Install reinforcement; Fabric - A252 bed; horizontal m2 0.08 ft2 0.01
wall; vertical m2 0.08 ft2 0.01
Install reinfrocement; Fabric - A393 bed; horizontal m2 0.10 ft2 0.01
wall; vertical m2 0.10 ft2 0.01
Install reinforcement; Fabric - D49 bed; horizontal m2 0.06 ft2 0.01
wall; vertical m2 0.06 ft2 0.01
Install reinforcement; Fabric - D98 bed; horizontal m2 0.08 ft2 0.01
wall; vertical m2 0.08 ft2 0.01
Sundry concrete work
Lay damp proof membrane; lapped at joints and intersection
horizontal m2 0.05 ft2 0.00
under stanchion, pump, base plate; n e 25 thick m2 1.14 ft2 0.11
under stanchion, pump, base plate;; over 25 but n e 37 thick m2 1.21 ft2 0.11
under stanchion, pump, base plate;; over 37 but n e 50 thick m2 1.51 ft2 0.14
under stanchion, pump, base plate;; over 50 but n e 100 thick m2 1.84 ft2 0.17
under stanchion, pump, base plate;; over 100 thick m3 8.57 yd3 6.54
under stanchion, pump, base plate; n e 25 thick m2 0.45 ft2 0.04
under stanchion, pump, base plate;; over 25 but n e 37 thick m2 0.64 ft2 0.06
under stanchion, pump, base plate;; over 37 but n e 50 thick m2 0.89 ft2 0.08
under stanchion, pump, base plate;; over 50 but n e 100 thick m2 1.21 ft2 0.11
under stanchion, pump, base plate;; over 100 thick m3 5.03 yd3 3.84
horizontal; polysulphide sealant;12 x 12mm m 0.10 ft 0.03
horizontal; polysulphide sealant;12 x 20mm m 0.12 ft 0.04
horizontal; polysulphide sealant; 20 x 20mm m 0.10 ft 0.03
horizontal; polysulphide sealant; 20 x 25mm m 0.10 ft 0.03
Form joint; expansion; vertical; slab; 12mm compressible filler board; n e 150mm thick m 0.10 ft 0.03
vertical; slab; 12mm compressible filler board; over 150 but n e 300mm thick
m 0.14 ft 0.04
vertical; slab; 12mm compressible filler board; over 300 but n e 450mm thick
m 0.20 ft 0.06
vertical; slab; 20mm compressible filler board; n e 150mm thick m 0.12 ft 0.04
vertical; slab; 20mm compressible filler board; over 150 but n e 300mm thick
m 0.18 ft 0.05
vertical; slab; 20mm thick compressible filler board; over 300 but n e 450mm deep
m 0.26 ft 0.08
Form joint; expansion; including 16mm dia dowel bar 600mm long; one end cast in and other end debonded
vertical; slab; 12mm compressible filler board; n e 150mm thick; dowel at 600mm centres
m 0.16 ft 0.05
vertical; slab; 12mm compressible filler board; over 150 but ne 300mm thick; dowel at 600mm centres
m 0.18 ft 0.06
vertical; slab; 12mm compressible filler board; over 300 but n e 450mm thick; dowel at 600mm centres
m 0.21 ft 0.07
Place grouting; cement and sand (1:2); including formwork; fair finished to exposed surface;
Place grouting; cement and sand (1:2); none shrink additive;including formwork; fair finished to exposed surface;
install reinforcementl; high tensile; in any location: bar - 8mm dia
Seal joint
Install reinforcement; high tensile; in any location: bar - 6mm dia
Install reinforcement; high tensile; in any location: bar - 10mm dia
304
vertical; slab; 12mm compressible filler board; n e 150mm thick; dowel at 450mm centres
m 0.19 ft 0.06
vertical; slab; 12mm compressible filler board; over 150 but n e 300mm thick; 450mm centres
m 0.20 ft 0.06
vertical; slab; 12mm compressible filler board; over 300 but n e 450mm thick; dowel at 450mm centres
m 0.24 ft 0.07
vertical; slab; 12mm compressible filler board; n e 150mm thick; dowel at 300mm centres
m 0.21 ft 0.06
vertical; slab; 12mm compressible filler board; over 150 but ne 300mm thick; dowel at 300mm centres
m 0.23 ft 0.07
vertical; slab; 12mm compressible filler board; over 300 but n e 450mm thick; dowel at 300mm centres
m 0.26 ft 0.08
Form joint; expansion; including 20mm dia dowel bar 600mm long; one end cast in and other end debonded
vertical in slab; 20mm compressible filler board; n e 150mm thick; dowel at 600mm centres
m 0.16 ft 0.05
vertical in slab; 20mm compressible filler board; over 150 but ne 300mm thick; dowel at 600mm centres
m 0.18 ft 0.06
vertical in slab; 20mm compressible filler board; over 300 but n e 450mm thick; dowel at 600mm centres
m 0.21 ft 0.07
vertical in slab; 20mm compressible filler board; n e 150mm thick; dowel at 450mm centres
m 0.19 ft 0.06
vertical in slab; 20mm compressible filler board; over 150 but n e 300mm thick; dowel at 450mm centres
m 0.20 ft 0.06
vertical in slab; 20mm compressible filler board; n e 150mm thick; dowel at 450mm centres
m 0.24 ft 0.07
vertical in slab; 20mm compressible filler board; n e 150mm thick; dowel at 300mm centres
m 0.21 ft 0.06
vertical in slab; 20mm compressible filler board; n e 150mm thick; dowel at 300mm centres
m 0.23 ft 0.07
vertical in slab; 20mm compressible filler board; n e 150mm thick; dowel at 300mm centres
m 0.26 ft 0.08
Form; contraction joint; crack inducer; including 16mm dia dowel 600mm long bar one end cast in and other end debonded
horizontal surface groove n e 20 x 25 mm; dowel at 600mm centres; irrespective depth of slab
m 0.22 ft 0.07
Form; longitudonal joint; including staggered 12mm dia tie bar cast in at 450mm centres
vertical in slab; n e 150mm thick; m 0.05 ft 0.02
vertical in slab; over 150 but n e 300mm thick; m 0.05 ft 0.02
vertical in slab; over 300 but n e 450mm thick; m 0.05 ft 0.02
column and beam; in area less than 5 m2 m2 0.19 ft2 0.02
column and beam; in area over 5m2 m2 0.13 ft2 0.01
general surface; over 300mm girth m2 0.19 ft2 0.02
Clean
Clean concrete to remove dirt, grease, oil and the like; approved cleaning agent
305
Treating surface of concrete
horizontal; in area n e 0.10m2 nr 0.15 nr 0.15
horizontal; in area over 0.10m2 but n e 1.00m2 nr 0.35 nr 0.35
vertical; in area n e 0.10m2 nr 0.15 nr 0.15
vertical; in area over 0.10m2 but n e 1.00m2 nr 0.35 nr 0.35
horizontal; m 0.16 ft 0.05
vertical; m 0.16 ft 0.05
Paint surface of metalwork See Surface finishes - Painting
Hack; surface of concrete horizontal m2 0.29 ft2 0.03
vertical m2 0.29 ft2 0.03
Grind; surface of concrete horizontal m2 0.29 ft2 0.03
vertical m2 0.29 ft2 0.03
Sand blast; surface of concrete horizontal m2 0.48 ft2 0.04
vertical m2 0.48 ft2 0.04
horizontal m2 0.30 m2 0.03
vertical m2 0.30 m2 0.03
sloping % % 0.00to falls % % 0.00to crossfalls % % 0.00
n e 50mm deep m 0.15 ft 0.04
over 50 but n e 100mm deep m 0.35 ft 0.11
over 100 but n e 200mm deep m 0.53 ft 0.16
Cutting; chase or rebate n e 50mm deep; n e 50mm wide m 0.29 ft 0.09
n e 50mm deep; over 50 but n e 100mm wide m 0.29 ft 0.09
over 50 but n e 100mm deep; n e 50mm wide m 0.44 ft 0.13
over 50 but n e 100mm deep; over 50 but 100mm wide m 0.44 ft 0.13
over 50 but n e 100mm deep; over 100 n e 150mm wide m 0.48 ft 0.15
over 100 but n e 200mm deep; over 50 but n e 100mm wide m 0.70 ft 0.21
over 100 but n e 200mm deep; over 100 but n e 150mm wide m 0.70 ft 0.21
pipe n e 55 dia; m 0.60 ft 0.18
pipe over 55 but n e 110mm dia; m 0.99 ft 0.30
pipe n e 55mm dia Nr 0.61 Nr 0.61
pipe over 55 but n e 110mm dia; Nr 0.99 Nr 0.99
for rag bolt; 50 mm deep Nr 0.20 Nr 0.20
for rag bolt; over 50 but n e 100mm deep Nr 0.20 Nr 0.20
100 x 100mm; over 50 but n e 100mm deep Nr 0.50 Nr 0.50
200 x 200mm; over 50 but n e 100mm deep Nr 0.53 Nr 0.53
100 x 100mm; over 100 but n e 200mm deep Nr 0.67 Nr 0.67
200 x 200mm ; over 100 but n e 200mm deep Nr 0.73 Nr 0.73
200 x 200mm; over 200 but n e 300mm deep Nr 0.80 Nr 0.80
300 x 300mm; over 200 but n e 300mm deep Nr 0.87 Nr 0.87
for 6mm dia bolt or dowel; over 50 but n e 100mm deep Nr 0.13 Nr 0.13
for 12mm dia bolt or dowel; over 50 but n e 100mm deep Nr 0.17 Nr 0.17
100 x 100mm; over 50 but n e 100mm deep Nr 0.50 Nr 0.50
200 x 200mm; over 50 but n e 100mm deep Nr 0.53 Nr 0.53
for 12 dia bolt or dowel; over 100 but n e 200mm deep Nr 0.19 Nr 0.19
for 16 dia bolt or dowel; over 100 but n e 200mm deep Nr 0.20 Nr 0.20
100 x 100mm; over 100 but n e 200mm deep Nr 0.67 Nr 0.67
200 x 200mm ; over 100 but n e 200 deep Nr 0.73 Nr 0.73
for 16 dia bolt or dowel; over 200 but n e 300mm deep Nr 0.22 Nr 0.22
for 20 dia bolt or dowel; over 200 but n e 300mm deep Nr 0.23 Nr 0.23
200 x 200mm; over 200 but n e 300mm deep Nr 0.80 Nr 0.80
300 x 300mm; over 200 but n e 300mm deep Nr 0.87 Nr 0.87
Provide all plant; diamond drilling bring to site; erect; maintain and remove all plant required to carry out
the workItem 0.00 Item 0.00
vertical; 75mm dia; over 100 but n e 200mm deep Nr 0.51 Nr 0.51
vertical; 75mm dia; over 200 but n e 300mm deep Nr 1.01 Nr 1.01
vertical; 100mm dia; over 100 but n e 200mm deep Nr 0.57 Nr 0.57
vertical; 100mm dia; over 200 but n e 300mm deep Nr 1.14 Nr 1.14
vertical; 150mm dia, over 100 but n e 200mm deep Nr 0.65 Nr 0.65
vertical; 150mm dia, over 200 but n e 300mm deep Nr 1.30 Nr 1.30
Cutting; hole
Drilling; hole
Cutting; pinning support
Cutting; pocket
Saw cutting
Fill in hole with suitable material, surface of concrete; finished flush with existing surface.
Fill crack with suitable material;surface of concrete; finished flush with existing surface
Prepare surface; surface of concrete; apply two coats of appoved bonding agent
Repair
Percentage adjustment to "treated surface" for work other than vertical or horizontal
306
Drilling; hole horizontal; 50mm dia, over 100 but n e 200mm deep Nr 0.81 Nr 0.81
horizontal; 50mm dia, over 200 n e 300mm deep Nr 1.62 Nr 1.62
horizontal; 75mm dia, over 100 but n e 200mm deep Nr 0.91 Nr 0.91
horizontal; 75mm dia, over 200 but n e 300mm deep Nr 1.83 Nr 1.83
vertical m 0.12 ft 0.04
horizontal m 0.12 ft 0.04
vertical m2 0.18 ft2 0.02
See also surface treatment - tanking
Prepare surface of concrete; apply approved sealing material; diaphragm walling
Remove defective jointing material between precast concrete units; reform joint and sealing with approved material
Repair
Removal of existing concrete structures only. For replacement use NEW rates
horizontal; volume n e 0.1m3 nr 0.35 Nr 0.35
horizontal; volume over 0.1 but n e 1.00m3 nr 0.30 Nr 0.30
horizontal; volume over 1.0m3 m3 0.25 yd3 0.19
vertical; volume n e 0.1m3 nr 0.35 Nr 0.35
vertical; volume over 0.1 but n e 1.00m3 nr 0.30 Nr 0.30
vertical; volume over 1.0m3 m3 0.25 yd3 0.19
horizontal; volume n e 0.1m3 nr 0.38 Nr 0.38
horizontal; volume over 0.1 but n e 1.00m3 nr 0.33 Nr 0.33
horizontal; volume over 1.0m3 m3 0.28 yd3 0.21
vertical; volume n e 0.1m3 nr 0.38 Nr 0.38
vertical; volume over 0.1 but n e 1.00m3 nr 0.33 Nr 0.33
vertical; volume over 1.0m3 m3 0.28 yd3 0.21
horizontal; volume n e 0.1m3 nr 0.38 Nr 0.38
horizontal; volume over 0.1 but n e 1.00m3 nr 0.33 Nr 0.33
horizontal; volume over 1.0m3 m3 0.28 yd3 0.21
vertical; volume n e 0.1m3 nr 0.38 Nr 0.38
vertical; volume over 0.1 but n e 1.00m3 nr 0.33 Nr 0.33
vertical; volume over 1.0m3 m3 0.28 yd3 0.21
0.00height n e 1.00m m2 0.75 ft2 0.07
height over 1.00m but n.e. 2.00m m2 0.75 ft2 0.07
height over 2.00m but n.e. 3.00m m2 0.75 ft2 0.07
height over 3.00m but n.e. 4.00m m2 0.75 ft2 0.07
height over 4.00m but n.e. 5.00m m2 0.75 ft2 0.07
height over 5.00m but n.e. 6.00m m2 0.75 ft2 0.07
0.00
125mm thick; height n e 1.00m m2 0.35 ft2 0.03
125mm thick; height over 1.00m but n.e. 2.00m m2 0.35 ft2 0.03
125mm thick; height over 2.00m but n.e. 3.00m m2 0.35 ft2 0.03
125mm thick; height over 3.00m but n.e. 4.00m m2 0.35 ft2 0.03
125mm thick; height over 4.00m but n.e. 5.00m m2 0.35 ft2 0.03
125mm thick; height over 5.00m but n.e. 6.00m m2 0.35 ft2 0.03
600mm thick m3 2.25 yd3 1.72
1000mm thick m3 2.35 yd3 1.79
Break out existing precast concrete structure, provide temporary support, remove material, prepare exposed surface
Replace
Break out existing plain concrete structure, provide temporary support, remove material, prepare exposed surface
Remove precast concrete retaining wall unit, provide temporary support.
Dismantle and remove existing precast concrete crib wall system and infilling;
Break out existing reinforced concrete structure, provide temporary support, remove material, prepare exposed surface
Break out and remove diaphagm wall, provide temporary support
307
Cast into concrete; filling tube with concrete single tube; pipe support anchor and guide; overall length 1.00 m; Nr 7.06 Nr 7.06
three tube; pipe support anchor and guide; overall length 5.25 m; Nr 19.80 Nr 19.80
0.00
mild steel dowel; 6mm dia Nr 0.05 Nr 0.05
mild steel dowel; 12mm dia Nr 0.05 Nr 0.05
mild steel dowel; 16mm dia Nr 0.07 Nr 0.07
mild steel dowel; 20mm dia Nr 0.08 Nr 0.08
tubular pipe support; 'tee' type 600 high Nr 0.56 Nr 0.56
tubular pipe support; 'tee' type 900 high Nr 0.56 Nr 0.56
tubular pipe support; 'tee' type 1500 high Nr 0.60 Nr 0.60
tubular pipe support; "goalpost" type 900 wide x 900 high Nr 0.89 Nr 0.89
tubular pipe support; "goalpost" type 1500 wide x 900 high Nr 0.89 Nr 0.89
tubular pipe support; "goalpost" type 1500 wide x 1500 high Nr 0.95 Nr 0.95
Rolled hollow section security post; 100 dia x 1.25m long; Nr 4.23 Nr 4.23
parabolt hot dipped galvanised; nut and washer; 12mm dia ne 150mm long
Nr 0.07 Nr 0.07
parabolt hot dipped galvanised; nut and washer; 16mm dia ne 150mm long
Nr 0.10 Nr 0.10
parabolt hot dipped galvanised; nut and washer; 16mm dia ne 225mm long
Nr 0.08 Nr 0.08
parabolt hot dipped galvanised; nut and washer; 20mm dia ne 225mm long
Nr 0.14 Nr 0.14
parabolt s s grade 316; nut and washer; 12mm dia ne 150mm long Nr 0.10 Nr 0.10
parabolt s s grade 316; nut and washer; 16mm dia ne 150mm long Nr 0.15 Nr 0.15
parabolt s s grade 316; nut and washer; 16mm dia ne 225mm long Nr 0.18 Nr 0.18
parabolt s s grade 316; nut and washer; 20mm dia ne 225mm long Nr 0.30 Nr 0.30
expanding sheath safety bolt; 12mm dia n e 150mm long Nr 0.05 Nr 0.05
expanding sheath safety bolt; 16mm dia n e 150mm long Nr 0.05 Nr 0.05
expanding sheath safety bolt; 20mm dia n e 150mm long Nr 0.04 Nr 0.04
ragbolt; nut and washer; 12 diameter n e 150mm long Nr 0.07 Nr 0.07
ragbolt; nut and washer; 16 diameter n e 225mm long Nr 0.02 Nr 0.02
Build into prepared pocket in concrete; grouting in cement sand mortar (1:2); protection with grease and tape
holding down bolt assembly; plate, nut, washer and sleeve; 12mm dia x 200mm long
Nr 0.29 Nr 0.29
holding down bolt assembly; plate, nut, washer and sleeve; 16mm dia x 375mm long
Nr 0.32 Nr 0.32
holding down bolt assembly; plate, nut, washer and sleeve; 20mm dia x 375mm long
Nr 0.37 Nr 0.37
holding down bolt assembly; plate, nut, washer and sleeve; 24mm dia x 375mm long
Nr 0.40 Nr 0.40
holding down bolt assembly; plate, nut, washer and sleeve; 24mm dia x 450mm long
Nr 0.41 Nr 0.41
holding down bolt assembly; plate, nut, washer and sleeve; 30mm dia x 450mm long
Nr 0.32 Nr 0.32
holding down bolt assembly; plate, nut, washer and sleeve; 30mm dia x 500mm long
Nr 0.34 Nr 0.34
Build into prepared pocket one end set with epoxy resin mortar; other end cast into concrete
Build into prepared pocket in concrete; protected with grease and tape
Build into prepared pocket in concrete with cement sand mortar (1:2); line and level; temporary support; taking delivery
No coding available
308
Q.2.1.4 Steelwork
STEELWORK
Fabricating
angle and tee; in length n e 1.50m; n e 10kg per m t 30.00 t 27.22
joist and channel; in length n e 1.50m; n e 10kg per m t 24.00 t 21.78
universal beam; in length n e 1.5m; n e 10kg per m t 20.00 t 18.15
universal column; in length n e 1.50m; over 10kg per m t 26.00 t 23.59
flat; in length n e 1.50m; n e 10kg per m t 20.00 t 18.15
hollow section; in length n e 1.50m; n e 10kg per m t 20.00 t 18.15
angle and tee; in length n e 1.50m; over 10 but n e 20kg per m t 27.00 t 24.50
joist and channel; in length n e 1.50m; over 10 but n e 20kg per m t 22.71 t 20.61
universal beam; in length n e 1.50m; over 10 but n e 20kg per m t 22.71 t 20.61
universal column; in length n e 1.50m; over 10 but n e 20kg per m t 25.00 t 22.69
flat; in length n e 1.50m; over 10 but n e 20kg per m t 31.00 t 28.13
hollow section; in length n e 1.50m; over 10 but n e 20kg per m t 22.71 t 20.61
connection and baseplate; 10 - 20kg per m t 25.00 t 22.69
angle and tee; in length n e 1.50m; over 20 but n e 50kg per m t 22.00 t 19.96
joist and channel; in length n e 1.50m; over 20 but n e 50kg per m t 17.00 t 15.43
universal beam; in length n e 1.50m; over 20 but n e 50kg per m t 19.00 t 17.24
universal column; in length n e 1.50m; over 20 but n e 50kg per m t 19.00 t 17.24
flats; in length n e 1.50m; over 20 but n e 50kg per m t 20.00 t 18.15
hollow section; in length n e 1.50m; over 20 but n e 50kg per m t 20.00 t 18.15
connection and baseplate; over 20 but n e 50kg per m t 16.00 t 14.52
angle and tee; in length n e 1.50m; over 50 but n e 100kg per m t 16.00 t 14.52joist and channel; in length n e 1.50m; over 50 but n e 100kg per m t 12.00 t 10.89
universal beam; in length n e 1.50m; over 50 but n e 100kg per m t 15.00 t 13.61universal column; in length n e 1.50m; over 50 but n e 100kg per m t 15.00 t 13.61
flat; in length n e 1.50m; over 50 but n e 100kg per m t 25.00 t 22.69
hollow section; in length n e 1.50m; over 50 but n e 100kg per m t 20.00 t 18.15
connection and baseplate; over 50 but n e 100kg per m t 12.00 t 10.89
universal beam; in length n e 1.50m; over 100kg per m t 17.00 t 15.43
universal column; in length n e 1.50m; over 100kg per m t 17.00 t 15.43
flat; in length n e 1.50m; over 100kg per m t 25.00 t 22.69
hollow section; in length n e 1.50m; over 100kg per m t 20.00 t 18.15
connection and baseplate; over 100kg per m t 12.00 t 10.89
angle and tee; in length over 1.50m; n e 10kg per m t 30.00 t 27.22
joist and channel; in length over 1.50m; n e 10kg per m t 24.00 t 21.78
universal beam; in length over 1.50m; n e 10kg per m t 20.00 t 18.15
universal column; in length over 1.50m; n e 10kg per m t 26.00 t 23.59
flat; in length over 1.50m; n e 10kg per m t 20.00 t 18.15
hollow section;in length over 1.50m; n e 10kg per m t 20.00 t 18.15
angle and tee; in length over 1.50m; over 10 but n e 20kg per m t 27.00 t 24.50joist and channel; in length over 1.50m; over 10 but n e 20kg per m t 23.00 t 20.87
universal beam; in length over 1.50m; over 10 but n e 20kg per m t 23.00 t 20.87
universal column; in length over 1.50m; over 10 but n e 20kg per m t 25.00 t 22.69
flat; 1in length over 1.50m; over 10 but n e 20kg per m t 31.00 t 28.13
hollow section; in length over 1.50m; over 10 but n e 20kg per m t 23.00 t 20.87
angle and tee; in length n e 1.50m; over 20 but n e 50kg per m t 22.00 t 19.96
joist and channel; in length n e 1.50m; over 20 but n e 50kg per m t 17.00 t 15.43
universal beam; in length n e 1.50m; over 20 but n e 50kg per m t 19.00 t 17.24
universal column; in length n e 1.50m; over 20 but n e 50kg per m t 19.00 t 17.24
flat; in length n e 1.50m; over 20 but n e 50kg per m t 20.00 t 18.15
hollow section; in length n e 1.50m; over 20 but n e 50kg per m t 20.00 t 18.15
angle and tee; in length over 1.50m; over 50 but n e 100kg per m t 16.00 t 14.52
joist and channel; in length over 1.50m; over 50 but n e 100kg per m t 12.00 t 10.89
universal beam; in length over 1.50m; over 50 but n e 100kg per m t 15.00 t 13.61universal column; in length over 1.50m; over 50 but n e 100kg per m t 15.00 t 13.61
flat; in length over 1.50m; over 50 but n e 100kg per m t 25.00 t 22.69
hollow section; in length over 1.50m; over 50 but n e 100kg per m t 20.00 t 18.15
universal beam; in length over 1.50m over 100kg per m t 17.00 t 15.43
universal column; in length over 1.50m; over 100kg per m t 17.00 t 15.43
flat; in length over 1.50m; over 100kg per m t 25.00 t 22.69
hollow section; in length over 1.50m; over 100kg per m t 20.00 t 18.15
Fabricate; welded or bolted member; galvanised; main structural member;
Fabricate; welded or bolted member; galvanised; main structural member;
Fabricate; welded or bolted member; galvanised; main structural member;
STEELWORK Norm Hrs. IMPERIAL
Norm Hrs. METRIC
New Work
Fabricate; welded or bolted member; galvanised; main structural member;
Fabricate; welded or bolted member; galvanised; main structural member;
Fabricate; welded or bolted member; galvanised; main structural member;
Fabricate; welded or bolted member; galvanised; main structural member;
Fabricate; welded or bolted member; galvanised; main structural member;
Fabricate; welded or bolted member; galvanised; main structural member;
Fabricate; welded or bolted member; galvanised; main structural member;
309
Labour on steelwork, fabrication
slotted hole; n e 10kg per m nr 0.07 nr 0.07
slotted hole; over 10 but n e 20kg per m nr 0.10 nr 0.10
slotted hole; over 20 but n e 50kg per m nr 0.12 nr 0.12
slotted hole; over 50 but n e 100kg per m nr 0.14 nr 0.14
slotted hole; over 100kg per m nr 0.16 nr 0.16
cranked member; n e 10kg per m nr 0.40 nr 0.40
cranked member; over 10 but n e 20kg per m nr 0.50 nr 0.50
cranked member; over 20 but n e 50kg per m nr 0.52 nr 0.52
cranked member; over 50 but n e 100kg per m nr 1.00 nr 1.00
cranked member; over 100kg per m nr 1.00 nr 1.00
percentage reduction to fabrication rates % % 0.00
Prepare and apply two coats of 'galvafroid' paint system steelwork t 10.00 t 9.07
Erecting
new structure; n e 10m high t 16.00 t 14.52
new structure; over 10 but n e 20m high t 19.00 t 17.24
new structure; over 20 but n e 30m high t 20.00 t 18.15
new structure; over 30 but n e 40m high t 21.00 t 19.06
inside existing structure; n e 10m high t 17.00 t 15.43
inside existing structure; over 10 but n e 20m high t 20.00 t 18.15
inside existing structure; over 20 but n e 30m high t 21.00 t 19.06
inside building; n e 10m high t 17.00 t 15.43
inside building; over 10 but n e 20m high t 20.00 t 18.15
inside building; over 20 but n e 30m high t 21.00 t 19.06
purlin and cladding rail; n e 10m high m 0.17 ft 0.05
purlin and cladding rail; over 10 but n e 20m high m 0.20 ft 0.06
purlin and cladding rail; over 20 but n e 30m high m 0.20 ft 0.06
12mm dia n e 150mm long nr 0.20 nr 0.20
16mm dia n e 200mm long nr 0.40 nr 0.40
20mm dia n e 225mm long nr 0.60 nr 0.60
12mm dia n e 150mm long nr 0.20 nr 0.20
16mm dia n e 200mm long nr 0.40 nr 0.40Install; galvanised mild steel safety chain 32 x 5mm; including eye bolt and hook nr 0.50 nr 0.50
Flooring
6mm thick; m2 2.00 ft2 0.19
8mm thick; m2 2.23 ft2 0.21
10mm thick; m2 2.40 ft2 0.22
6mm thick m2 1.50 ft2 0.14
8mm thick m2 1.60 ft2 0.15Extra over; erect chequer plate flooring; drilling and tapping; countersunk bolts m2 0.33 ft2 0.03Extra over; erect chequer plate flooring; drilling steel; countersunk bolts m2 0.66 ft2 0.06
6mm thick m 0.70 ft 0.21
8mm thick m 0.70 ft 0.21
10mm thick m 0.70 ft 0.21Extra over; erect chequer plate flooring; circular cutting 6mm thick m 1.00 ft 0.31
8mm thick m 1.00 ft 0.31
10mm thick m 1.00 ft 0.31
6mm thick m 0.70 ft 0.21
8mm thick m 0.70 ft 0.21
10mm thick m 0.70 ft 0.21
6mm thick; size 150 x 50mm nr 0.70 nr 0.70
8mm thick; size 150 x 50mm nr 0.70 nr 0.70
10mm thick; size 150 x 50mm nr 0.70 nr 0.70
25mm thick; m2 1.50 ft2 0.14
30mm thick; m2 0.80 ft2 0.07
25mm thick; n e 300 width m2 0.50 ft2 0.05
25mm thick; over 300 but n e 500 wide m2 0.75 ft2 0.07
25mm thick; size 800 x 200 nr 0.50 nr 0.50
25mm thick m 0.70 ft 0.21
30mm thick m 0.70 ft 0.21
25mm thick m 1.00 ft 0.31
30mm thick m 1.00 ft 0.31
25mm thick m 0.70 ft 0.21
30mm thick m 0.70 ft 0.21
25mm thick m 0.50 ft 0.15
30mm thick; m 0.50 ft 0.15
horizontal; 130 x 6mm toe plate; m 0.50 ft 0.15
height allowance; over 10 but n e 20m high m2 0.13 ft2 0.01
height allowance; over 20 but n e 30m high m2 0.16 ft2 0.01
height allowance; over 30 but n e 40m high m2 0.20 ft2 0.02
Fabricate; cut or form; all sizes and types of members
Erect; chequer plate flooring; standard pattern; galvanised; clamped to steelwork
Erect; framing member;
Erect; framing member;
Erect; framing member;
Install; m s 'Parabolt' sleeve anchor; complete with nut and washer;
Erect; Zed purlin, including fixing accessories and cleats
Erect; chequer plate flooring ; manhole or duct cover; laid loose
Reduction for omission of galvanising structural steel members from fabrication activity
Extra over; erect chequer plate flooring; labour notching around obstruction
Extra over; erect chequer plate flooring; raking cutting
Extra over; erect steel flooring;
Extra over; erect chequer plate floooring; labour forming lifting hole
Extra over; erect open grid flooring; forming nosing to edge
Extra over; erect open grid floring; circular cutting;
Extra over; erect open grid flooring; raking cutting; including edge bar
Extra over; erect open grid flooring; notching around obstruction
Erect open grid flooring; stair tread; including nosing bar and supporting flats; drilled and bolted to steelwork stringers
Install; compressible sleeve anchor bolt; complete with nut and washer;
Erect; open grid flooring; trench cover; laid loose;
Erect; open grid flooring; galvanised; clipped to steelwork
Fabricate; cut or form; all sizes and types of members
310
Handrailing
25mm nominal bore; horizontal m 1.50 ft 0.46
25mm nominal bore; inclined; to staircase m 1.50 ft 0.46
25mm nominal bore; horizontal m 0.50 ft 0.15
forming bend n e 0.50m radius Nr 1.00 nr 1.00
forming bend over 0.50 but n e 1.00m radius Nr 0.90 nr 0.90
bend on plan and elevation nr 0.75 nr 0.75
existing, (each rail) Nr 0.75 nr 0.75
base stringer Nr 0.50 nr 0.50
over 10 but n e 20m high m 0.20 ft 0.06
over 20 but n e 30m high m 0.25 ft 0.08
over 30 but n e 40m high m 0.30 ft 0.09
Ladder
formed from 70 x 70 x 8mm angle; m 1.00 ft 0.31
Extra over; erect; ladder safety cage Nr 1.00 nr 1.00
bolting feet to concrete base (pair) nr 0.60 nr 0.60
additional safety protection to elevated floor at base nr 2.00 nr 2.00
structural steel member t 14.00 t 12.70
secondary steel member t 15.00 t 13.61
open grid flooring m2 0.75 ft2 0.07
chequerplate flooring m2 1.25 ft2 0.12
handrailing m 3.15 ft 0.96
staircase Nr 62.50 nr 62.50
ladder Nr 12.50 nr 12.50
Install holding down bolt assembly, into concrete foundation. See concrete work
structural steel members t 11.50 t 10.44
secondary steel member t 13.50 t 12.25
structural steel member t 12.75 t 11.57
secondary steel member t 14.35 t 13.02
open grid flooring m2 0.87 ft2 0.08
chequerplate flooring m2 0.87 ft2 0.08
handrailing m 0.96 ft 0.29
staircase nr 37.50 nr 37.50
ladder nr 6.50 nr 6.50
open grid flooring m2 0.95 ft2 0.09
chequerplate flooring m2 0.96 ft2 0.09
handrailing m 0.95 ft 0.29
staircase nr 40.00 nr 40.00
ladder nr 6.50 nr 6.50
Miscellanous metalwork
lintel; 6mm thick x 36mm wide flat m 0.28 ft 0.09
lintel; 9mm thick x 50mm wide flat m 0.35 ft 0.11
arch support; 6mm thick x 36mm wide flat m 0.73 ft 0.22
arch support; 9mm thick x 50mm wide flat m 0.78 ft 0.24
metal frame or plate; n e 100mm wide m 0.07 ft 0.02
metal frame or plate; n e 100mm wide; point one side with mastic m 0.18 ft 0.05
metal frame or plate; n e 100mm wide; point two sides with mastic m 0.28 ft 0.09
Build in; bedded in cement mortar (1:4)
Erect; bolted connections
Erect; welded connections
Erect; bolted connections
Erect; welded connections
Fabricate, offsite, steel; bolted and welded member; including blast cleaning and applying one coat chromate primer, touch up primer and two coats decorative paint and sealer
Extra over; erect; ladder
Erect; ladder galvanised mild steel; including all fixings and safety chain; bolted to steelwork; fixed at any height
Extra over; erect tubular mild steel rail; height allowance
Extra over; erect tubular mild steel rail ; connecting
Extra over; erect tubular mild steel rail; change of direction
Erect; tubular galvanised mild steel, top, middle rail and standards;
Erect; tubular galvanised mild steel; single rail ; bolted to steelwork or concrete; including all drilling and bolting
Note that fabrication hours includes for offsite pr eparation for surface treatment. Blasting surface a nd applying priming coat. Surface Treatment includes for on site touch up onl y
Not applicable see surface treatments25 thick m2 0.30 ft2 0.03
37 thick m2 0.37 ft2 0.03
50 thick m2 0.41 ft2 0.04
See Concretework for NEW grouting 100 thick m2 0.50 ft2 0.05
over 100 thick m3 0.50 yd3 0.38
Clean out; grout under steelwork base plate
Clean
311
Repairs to painting see Surface Treatment
total weight; n e 0.10 tonnes t 26.00 t 23.59
total weight; over 0.10 but n e 0.50 tonnes t 26.00 t 23.59
total weight; over 0.50 but n e 1.00 tonnes t 26.00 t 23.59
total weight; over 1.00 but n e 1.50 tonnes t 26.00 t 23.59
total weight; over 1.50 but n e 2.00 tonnes t 35.00 t 31.76
total weight exceeding 2.00 tonnes t 45.00 t 40.83Extra over; take down structural steelwork; cold cutting percentage addition; cold cutting in lieu of hot cutting % 20.00 % 20.00
6mm thick flooring m2 1.70 ft2 0.16
8mm thick flooring m2 1.70 ft2 0.16
10mm thick flooring m2 1.70 ft2 0.16
25mm thick flooring m2 1.70 ft2 0.16
30mm thick flooring m2 1.70 ft2 0.16
25mm dia m 0.50 ft 0.15
open grid flooring (area n e 10m2) m2 1.10 ft2 0.10
chequerplate flooring (area n e 10m2) m2 1.11 ft2 0.10
handrailing (length n e 1.50m) m 1.15 ft 0.35
open grid flooring (area n e 10m2) m2 1.08 ft2 0.10
chequerplate flooring (areas n e 10m2) m2 1.09 ft2 0.10
handrailing (length n e 1.50m) m 1.25 ft 0.38
less than 10 in total nr 0.50 nr 0.50
over 10 but n e 25 in total nr 0.40 nr 0.40
over 25 but n e 100 in total nr 0.20 nr 0.20
over 100 in total nr 0.10 nr 0.10
Carefully take down structural steelwork including cutting out bolts, hot cutting; lowering to ground, providing temporary support; storage at location; return members and refixing with new bolts.
Replace clip to open grid flooring; isolated
Re-erect; welded connection
Re-erect; bolted connection
Carefully take up chequer plate or open grid flooring including unbolting fixing devices; setting aside, providing temporary support and protection; return and refix with new bolts or clips.
Carefully dismantle tubular handrailing; including unbolting fixing devices; setting aside, provide temporary protection; return and refix with new bolts
Repair
312
size of member n e 100kg Nr 1.54 nr 1.54
size of member over 100 but n e 250kg Nr 1.54 nr 1.54
size of member over 250 but n e 500kg Nr 1.54 nr 1.54
size of member over 500 but n e 1000kg Nr 1.54 nr 1.54
size of member over 1000kg Nr 1.54 nr 1.54
open grid flooring (area n e 10m2) m2 1.65 ft2 0.15chequerplate flooring (area n e 10m2) m2 1.65 ft2 0.15handrailing (length n e 1.5m) m 1.65 ft 0.50
total weight; n e 0.10 tonnes t 10.00 t 9.07
total weight;over 0.10 but n e 0.50 tonnes t 10.00 t 9.07
total weight; over 0.50 but n e 1.00 tonnes t 10.00 t 9.07
total weight; over 1.00 but n e 1.50 tonnes t 10.00 t 9.07
total weight; over 1.50 but n e 2.00 tonnes t 10.00 t 9.07
total weight; exceeding 2.00 tonnes t 20.00 t 18.15
total weight; n e 0.10 tonnes t 10.00 t 9.07
total weight; over 0.10 but n e 0.50 tonnes t 10.00 t 9.07
total weight;over 0.50 but n e 1.00 tonnes t 10.00 t 9.07
total weight; over 1.00 but ne 1.50 tonnes t 10.00 t 9.07
total weight; over 1.50 but n e 2.00 tonnes t 10.00 t 9.07
total weight; exceeding 2.00 tonnes t 20.00 t 18.15Extra over; take down structural steelwork; percentage addition; cold cutting in lieu of hot cutting % 20.00 % 20.00
mild steel n e 13mm thick m 1.50 ft 0.46
mild steel over 13 but ne 25mm thick m 2.00 ft 0.61
mild steel n e 13mm thick m 1.00 ft 0.31
mild steel over 13 but ne 25mm thick m 1.50 ft 0.46
size of member n e 100kg Nr 0.33 nr 0.33
size of member over 100 but n e 250kg Nr 0.38 nr 0.38
size of member over 250 but n e 500kg Nr 0.43 nr 0.43
size of member over 500 but n e 1000kg Nr 0.48 nr 0.48
size of member over 1000kg Nr 0.53 nr 0.53
size of member n e 100kg Nr 0.37 nr 0.37
size of member over 100 but n e 250kg Nr 0.42 nr 0.42
size of member over 250 but n e 500kg Nr 0.47 nr 0.47
size of member over 500 but n e 1000kg Nr 0.52 nr 0.52
size of member over 1000kg Nr 0.57 nr 0.57
size of member n e 100kg Nr 0.31 nr 0.31
size of member over 100 but n e 250kg Nr 0.36 nr 0.36
size of member over 250 but n e 500kg Nr 0.41 nr 0.41
size of member over 500 but n e 1000kg Nr 0.46 nr 0.46
size of member over 1000kg Nr 0.51 nr 0.51
size of member n e 100kg Nr 0.35 nr 0.35
size of member over 100 but n e 250kg Nr 0.40 nr 0.40
size of member over 250 but n e 500kg Nr 0.46 nr 0.46
size of member over 500 but n e 1000kg Nr 0.50 nr 0.50
size of member over 1000kg Nr 0.55 nr 0.55
open grid flooring m2 0.62 ft2 0.06
chequerplate flooring m2 0.52 ft2 0.05
handrailing m 0.23 ft 0.07
staircase Nr 5.00 nr 5.00
ladder Nr 1.25 nr 1.25
n e 25mm thick; for bolt n e 25mm dia Nr 0.60 nr 0.60
n e 25mm thick; slotted; for bolt n e 25mm dia; Nr 0.80 nr 0.80
6mm fillet weld m 1.00 ft 0.31
9mm fillet weld m 1.50 ft 0.46
bolt n e 25mm dia; in quanitities 1 - 10 Nr 0.18 nr 0.18
bolt n e 25mm dia; in quanitities 10 - 50 Nr 0.13 nr 0.13n e 25mm dia; to suit 25mm bore nr 0.10 nr 0.10
n e 150mm girth nr 0.10 nr 0.10
25mm bore handrailing m 0.60 ft 0.18
percentage addition for working at height 10 - 20m % 10.00 % 10.00
percentage addition for working at height 20 - 30m % 15.00 % 15.00
percentage addition for working at height 30 - 40m % 20.00 % 20.00
Extra over; remove and replace steelwork items; height allowance
Remove galvanised bolt and replace; in any location
Welding steelwork; site; in any location
Drilling steelwork; site
Welding new steelwork member into place on site; lifting into position, including removing temporary support
Bolting new steel member into place; lifting into position, including removing temporary support
Dismantle secondary structure; provide temporary support; cutting steel member from structural frame, lowering to ground and disposal
Dismantle steelwork structure; provide temporary support, unbolting steel member from structural frame, lowering to ground and disposal
Fabricate, offsite,
Fabricate, offsite, individual structural steel member
Take down structural steelwork including cutting out bolts, lowering to ground, disposal; hot cutting
Extra for; grinding and touching up surface finish; exposed edge;
Take down structural steelwork including cutting out bolts, lowering to ground, storage at location; hot cutting;
Extra for; take down structural steelwork; hot cutting; including grinding and touching up surface finish exposed edge
Replace
Remove galvanised m s hook bolt and replace complete with nut and washers; in any location
Carefully dismantle; tubular handrail; provide temporary support and protection, dispose
Remove galvanised m s 'U' bolt and replace complete with nut and washers; in any location
Dismantle, provide temporary support.
313
Q.2.1.5 Masonry
BRICKWORK
wall; half brick thick m2 1.12 ft2 0.10
facework one side; half brick thick m2 1.33 ft2 0.12
facework both sides; half brick thick m2 1.56 ft2 0.15
extra over; engineering brickwork; half brick thick; skin of hollow wall m2 0.11 ft2 0.01
extra over; engineering brickwork; half brick thick; building against other work m2 0.12 ft2 0.01
wall; one brick thick m2 1.92 ft2 0.18
facework one side; one brick thick m2 2.11 ft2 0.20
facework both sides; one brick thick m2 2.35 ft2 0.22
extra over; engineering brickwork; one brick thick; skin of hollow wall m2 0.12 ft2 0.01
extra over; engineering brickwork; one brick thick; building against other work m2 0.12 ft2 0.01
wall; one and a half brick thick m2 2.38 ft2 0.22
facework one side; one and a half brick thick m2 2.48 ft2 0.23
facework both sides; one and a half brick thick m2 2.69 ft2 0.25
extra over; engineering brickwork; one and a half brick thick; skin of hollow wall m2 0.17 ft2 0.02
extra over; engineering brickwork; one and a half brick thick; building against other workm2 0.17 ft2 0.02
isolated pier; half brick thick m2 1.23 ft2 0.11
facework all sides; half brick thick m2 1.45 ft2 0.13
isolated pier; one brick thick m2 2.08 ft2 0.19
facework all sides;one brick thick m2 2.28 ft2 0.21
isolated pier; one and a half brick thick m2 2.29 ft2 0.21
facework all sides; one and a half brick thick m2 2.55 ft2 0.24
isolated casing; half brick thick m2 1.23 ft2 0.11
isolated casing; one brick thick m2 2.08 ft2 0.19
isolated casing; one and a half brick thick m2 2.29 ft2 0.21
projection; 225mm wide; half brick thick m 0.35 ft 0.11
projection; 337mm wide; half brick thick m 0.45 ft 0.14
projection; 440mm wide; half brick thick m 0.59 ft 0.18
projection; 552mm wide; half brick thick m 0.71 ft 0.22
percentage adjustment for each additional half brick width; projection % % 0.00
bonding end to existing brickwork; half brick thick m 0.10 ft 0.03
projection; 225mm wide; one brick thick m 0.65 ft 0.20
projection; 337mm wide; one brick thick m 0.82 ft 0.25
projection; 440mm wide; one brick thick m 1.06 ft 0.32
projection; 552mm wide; one brick thick m 1.23 ft 0.37
percentage adjustment for each additional one brick width; projection % % 0.00
bonding end to existing brickwork; one brick thick m 0.18 ft 0.05
projection; 225mm wide; one and a half brick thick m 0.93 ft 0.28
projection; 337mm wide; one and a half brick thick m 1.12 ft 0.34
projection; 440mm wide; one and a half brick thick m 1.54 ft 0.47
projection; 552mm wide; one and a half brick thick m 1.74 ft 0.53
bonding end to existing brickwork; one and a half brick thick m 0.27 ft 0.08
closing cavity vertically; 50mm wide; half brick thick m 0.17 ft 0.05
closing cavity horizontally; 50mm wide; half brick thick m 0.21 ft 0.06
closing cavity raking; 50mm wide; half brick thick m 0.21 ft 0.06
closing cavity vertically; 75mm wide; half brick thick m 0.17 ft 0.05
closing cavity horizontally; 75mm wide; half brick thick m 0.25 ft 0.08
closing cavity raking; 75mm wide; half brick thick m 0.25 ft 0.08
Norm Hrs. IMPERIAL
New Work
Norm Hrs. METRICMASONRY
Lay; engineering brickwork; Class B to BS3921 Table 6; bedded, jointed and pointed cement mortar (1:4)
314
wall; half brick thick m2 1.05 ft2 0.10
facework one side; half brick thick m2 1.18 ft2 0.11
facework both sides; half brick thick m2 1.33 ft2 0.12
extra over; facing brickwork; half brick thick; skin of hollow wall m2 0.14 ft2 0.01
extra over; facing brickwork;half brick thick; building against other work m2 0.14 ft2 0.01
wall; one brick thick m2 1.86 ft2 0.17
facework one side; one brick thick m2 2.18 ft2 0.20
facework both sides; one brick thick m2 2.39 ft2 0.22
extra over; facing brickwork; one brick thick;skin of hollow wall m2 0.14 ft2 0.01
extra over; facing brickwork; one brick thick; building against other work m2 0.14 ft2 0.01
wall; one and a half brick thick m2 3.89 ft2 0.36
facework one side; one and a half brick thick m2 4.02 ft2 0.37
facework both sides; one and a half brick thick m2 4.15 ft2 0.39
extra over; facing brickwork; one and ahalf brick thick;skin of hollow wall m2 0.14 ft2 0.01
extra over; facing brickwork; one and a half brick thick; building against other workm2 0.14 ft2 0.01
isolated pier; half brick thick m2 1.54 ft2 0.14
facework all sides; half brick thick m2 1.67 ft2 0.16
isolated pier; one brick thick m2 2.84 ft2 0.26
facework all sides; one brick thick m2 2.97 ft2 0.28
isolated pier; one and a half brick thick m2 3.82 ft2 0.36
facework all sides; one and a half thick m2 3.95 ft2 0.37
isolated casing; half brick thick m2 1.54 ft2 0.14
isolated casing; one brick thick m2 2.84 ft2 0.26
isolated casing; one and a half brick thick m2 3.82 ft2 0.36
projection; 225mm wide; half brick thick m 0.44 ft 0.14
projection; 337mm wide; half brick thick m 0.57 ft 0.17
projection; 440mm wide; half brick thick m 0.73 ft 0.22
projection; 552mm wide; half brick thick m 0.87 ft 0.27
percentage adjustment for each additional half brick width; projection % % 0.00
bonding end to existing brickwork; half brick thick m 0.19 ft 0.06
projection; 225mm wide; one brick thick m 0.84 ft 0.25
projection; 337mm wide; one brick thick m 1.05 ft 0.32
projection; 440mm wide; one brick thick m 1.33 ft 0.41
projection; 552mm wide; one brick thick m 1.55 ft 0.47
percentage adjustment for each additional one brick width; projection % % 0.00
bonding end to existing brickwork; one brick thick m 0.30 ft 0.09
projection; 225mm wide; one and a half brick thick m 1.20 ft 0.37
projection; 337mm wide; one and a half brick thick m 1.48 ft 0.45
projection; 440mm wide; one and a half brick thick m 1.96 ft 0.60
projection; 552mm wide; one and a half brick thick m 2.22 ft 0.68
bonding end to existing brickwork; one and a half brick thick m 0.41 ft 0.12
closing cavity vertically; 50mm wide; half brick thick m 0.24 ft 0.07
closing cavity horizontally; 50mm wide; half brick thick m 0.28 ft 0.08
closing cavity raking; 50mm wide; half brick thick m 0.28 ft 0.08
closing cavity vertically; 75mm wide; half brick thick m 0.24 ft 0.07
closing cavity horizontally; 75mm wide; half brick thick m 0.28 ft 0.08
closing cavity raking; 75mm wide; half brick thick m 0.28 ft 0.08
brick on edge band; horizontal; half brick wide; m 0.31 ft 0.10
brick on edge band; horizontal; one brick wide; m 0.38 ft 0.12
percentage adjustment; brick on edge band; for vertical band % % 0.00
brick on end band; horizontal; half brick wide; m 0.42 ft 0.13
brick on end band; horizontal; one brick wide; m 0.76 ft 0.23
percentage adjustment; brick on end band; for vertical band % % 0.00
brick laid flat; sill, coping or step; one brick wide ; horizontal m 0.25 ft 0.08
brick laid flat; sill, coping or step; one brick wide; raking m 0.29 ft 0.09
brick on edge; sill, coping or step; one brick wide ; horizontal m 0.31 ft 0.10
brick on edge; sill, coping or step; one brick wide; raking m 0.36 ft 0.11
brick on end; sill, coping or step; one brick wide ; horizontal m 0.42 ft 0.13
brick on end; sill, coping or step; one brick wide; raking m 0.47 ft 0.14
Lay; facing brickwork; to BS 3921; in cement mortar(1;4)
315
wall 100mm thick; m2 0.55 ft2 0.05
wall 100mm thick; facework; one side m2 0.62 ft2 0.06
wall 100mm thick; facework; two sides m2 0.80 ft2 0.07
extra over blockwork; 100mm thick; building against other work m2 0.07 ft2 0.01
wall 150mm thick m2 0.77 ft2 0.07
wall 150mm thick; facework; one side m2 0.73 ft2 0.07
wall 150mm thick; facework; two sides m2 0.84 ft2 0.08
extra over blockwork; 150mm thick; building against other work m2 0.09 ft2 0.01
wall 215mm thick m2 1.00 ft2 0.09
wall 215mm thick; facework; one side m2 1.07 ft2 0.10
wall 215mm thick; facework; two sides m2 1.13 ft2 0.11
extra over blockwork; 215mm thick; building against other work m2 0.11 ft2 0.01
isolated pier; 100mm thick m2 0.62 ft2 0.06
facework 100mm thick; flush pointing all sides m2 0.68 ft2 0.06
isolated pier; 150mm thick m2 0.84 ft2 0.08
facework 150mm thick; flush pointing all sides m2 0.90 ft2 0.08
isolated pier; 215mm thick m2 1.07 ft2 0.10
facework 215mm thick; flush pointing all sides m2 1.13 ft2 0.11
isolated casing; 100mm thick m2 0.62 ft2 0.06
isolated casing; 150mm thick m2 0.84 ft2 0.08
isolated casing; 215mm thick m2 1.07 ft2 0.10
projection 100mm wide; 100mm thick block m 0.31 ft 0.10
projection 150mm wide; 100mm thick block m 0.31 ft 0.10
projection 215mm wide; 100mm thick block m 0.31 ft 0.10
projection 300mm wide; 100mm thick block m 0.31 ft 0.10
projection 400mm wide; 100mm thick block m 0.31 ft 0.10
projection 450mm wide; 100mm thick block m 0.51 ft 0.15
percentage adjustment for each additional 100 block width; projection % % 0.00
facework return; 100mm thick block, flush pointing; 100mm wide; m2 0.38 ft2 0.04
facework return, 100mm thick block; flush pointing; 300mm wide; m2 0.38 ft2 0.04
facework return, 100mm thick block; flush pointing; 400mm wide; m2 0.38 ft2 0.04
facework return, 100mm thick block; flush pointing; 450mm wide; m2 0.57 ft2 0.05
bonding end 100mm thick block; to existing blockwork m 0.13 ft 0.04
projection 100mm wide; 150mm thick block m 0.42 ft 0.13
projection 150mm wide; 150mm thick block m 0.42 ft 0.13
projection 215mm wide; 150mm thick block m 0.42 ft 0.13
projection 300mm wide; 150mm thick block m 0.42 ft 0.13
projection 400mm wide; 150mm thick block m 0.42 ft 0.13
projection 450mm wide; 150mm thick block m 0.69 ft 0.21
percentage adjustment for each additional 150mm block width; projection % % 0.00facework return; 150mm thick block, flush pointing; 150mm wide; m2 0.48 ft2 0.04
facework return; 150mm thick block, flush pointing; 300mm wide; m2 0.48 ft2 0.04
facework return; 150mm thick block, flush pointing; 450mm wide; m2 0.76 ft2 0.07
bonding end 150mm thick block; to existing blockwork m 0.26 ft 0.08
projection 100mm wide; 215mm thick block m 0.52 ft 0.16
projection 150mm wide; 215mm thick block m 0.52 ft 0.16
projection 215mm wide; 215mm thick block m 0.52 ft 0.16
projection 300mm wide; 215mm thick block m 0.52 ft 0.16
projection 400mm wide; 215mm thick block m 0.52 ft 0.16
projection 450mm wide; 215mm thick block m 0.85 ft 0.26
percentage adjustment for each additional 215mm block width; projection % % 0.00facework return; 215mm thick block, flush pointing; 215mm wide; m2 0.59 ft2 0.05
bonding end 215mm thick block; to existing blockwork m 0.33 ft 0.10
closing cavity vertically; 50mm wide; 100mm thick block m 0.20 ft 0.06
closing cavity horizontally; 50mm wide; 100mm thick block m 0.22 ft 0.07
closing cavity raking; 50mm wide; 100mm thick block m 0.22 ft 0.07
closing cavity vertically; 75mm wide; 100mm thick block m 0.20 ft 0.06
closing cavity horizontally; 75mm wide; 100mm thick block m 0.22 ft 0.07
closing cavity raking; 75mm wide; 100mm thick block m 0.22 ft 0.07
closing cavity vertically; 50mm wide; 150mm thick block m 0.20 ft 0.06
closing cavity horizontally; 50mm wide; 150mm thick block m 0.22 ft 0.07
closing cavity raking; 50mm wide; 150mm thick block m 0.22 ft 0.07
closing cavity vertically; 75mm wide; 150mm thick block m 0.20 ft 0.06
closing cavity horizontally; 75mm wide; 150mm thick block m 0.22 ft 0.07
closing cavity raking; 75mm wide; 150mm thick block m 0.22 ft 0.07
closing cavity vertically; 50mm wide; 215mm thick block m 0.20 ft 0.06
closing cavity horizontally; 50mm wide; 215mm thick block m 0.22 ft 0.07
closing cavity raking; 50mm wide; 215mm thick block m 0.22 ft 0.07
closing cavity vertically; 75mm wide; 215mm thick block m 0.20 ft 0.06
closing cavity horizontally; 75mm wide; 215mm thick block m 0.22 ft 0.07
closing cavity raking; 75mm wide; 215mm thick block m 0.22 ft 0.07
Lay; precast concrete blockwork: BS 6073; natural aggregate; compresive strength 7N/mm2; 440 x 215 mm in cement mortar (1:6)
316
wall 100mm thick; m2 0.60 ft2 0.06
facework 100mm thick; flush pointing one side m2 0.79 ft2 0.07
facework 100mm thick; flush pointing both sides m2 0.74 ft2 0.07
extra over blockwork; 100mm thick; building against other work m2 0.07 ft2 0.01
wall 140mm thick m2 0.79 ft2 0.07
facework 140mm thick; flush pointing one side m2 0.85 ft2 0.08
facework 140mm thick; flush pointing both sides m2 0.92 ft2 0.09
extra over blockwork; 140mm thick; building against other work m2 0.09 ft2 0.01
wall 215mm thick m2 1.01 ft2 0.09
facework 215mm thick; flush pointing one side m2 1.08 ft2 0.10
facework 215mm thick; flush pointing both sides m2 1.14 ft2 0.11
extra over blockwork; 215mm thick; building against other work m2 0.11 ft2 0.01
isolated pier; 100mm thick m2 0.67 ft2 0.06
facework 100mm thick; flush pointing all sides m2 0.74 ft2 0.07
isolated pier; 140mm thick m2 0.85 ft2 0.08
facework 140mm thick; flush pointing all sides m2 0.92 ft2 0.09
isolated pier; 215mm thick m2 1.08 ft2 0.10
facework 215mm thick; flush pointing all sides m2 1.14 ft2 0.11
isolated casing; 100mm thick m2 0.67 ft2 0.06
isolated casing; 140mm thick m2 0.85 ft2 0.08
isolated casing; 215mm thick m2 1.08 ft2 0.10
projection 100mm wide; 100mm thick block m 0.36 ft 0.11
projection 140mm wide; 100mm thick block m 0.36 ft 0.11
projection 215mm wide; 100mm thick block m 0.36 ft 0.11
projection 300mm wide; 100mm thick block m 0.36 ft 0.11
projection 400mm wide; 100mm thick block m 0.36 ft 0.11
projection 450mm wide; 100mm thick block m 0.58 ft 0.18
percentage adjustment for each additional 100 block width; projection % % 0.00facework return; 100mm thick block, flush pointing; 100mm wide; m2 0.43 ft2 0.04
facework return, 100mm thick block; flush pointing; 300mm wide; m2 0.43 ft2 0.04
facework return, 100mm thick block; flush pointing; 400mm wide; m2 0.43 ft2 0.04
bonding end 100mm thick block; to existing blockwork m 0.11 ft 0.03
projection 100mm wide; 140mm thick block m 0.44 ft 0.13
projection 140mm wide; 140mm thick block m 0.44 ft 0.13
projection 215mm wide; 140mm thick block m 0.36 ft 0.11
projection 300mm wide; 140mm thick block m 0.36 ft 0.11
projection 400mm wide; 140mm thick block m 0.36 ft 0.11
projection 450mm wide; 140mm thick block m 0.74 ft 0.22
percentage adjustment for each additional 140mm block width; projection % % 0.00facework return; 140mm thick block, flush pointing; 140mm wide; m2 0.51 ft2 0.05
facework return; 140mm thick block, flush pointing; 300mm wide; m2 0.51 ft2 0.05
facework return; 140mm thick block, flush pointing; 450mm wide; m2 0.80 ft2 0.07
bonding end 140mm thick block; to existing blockwork m 0.22 ft 0.07
projection 100mm wide; 215mm thick block m 0.55 ft 0.17
projection 140mm wide; 215mm thick block m 0.55 ft 0.17
projection 215mm wide; 215mm thick block m 0.55 ft 0.17
projection 300mm wide; 215mm thick block m 0.55 ft 0.17
projection 400mm wide; 215mm thick block m 0.55 ft 0.17
projection 450mm wide; 215mm thick block m 0.90 ft 0.28
percentage adjustment for each additional 215mm block width; projection % % 0.00facework return; 215mm thick block, flush pointing; 215mm wide; m2 0.61 ft2 0.06
bonding end 215mm thick block; to existing blockwork m 0.33 ft 0.10
Lay; aerated precast concrete blockwork; 440 x 215 as BS 6073, 1364 in cement mortar(1;6)
317
Labour on masonry
50mm wide; building in ends of and including wall ties m2 0.03 ft2 0.00
75mm wide; building in ends of and including wall ties m2 0.03 ft2 0.00
100mm wide; building in ends of and including wall ties m2 0.05 ft2 0.00
50mm wide; building in ends of and including wall ties m2 0.27 ft2 0.02
75mm wide; building in ends of and including wall ties m2 0.27 ft2 0.02
100mm wide; building in ends of and including wall ties m2 0.31 ft2 0.03
pipe n e 55mm dia; make good; half brick wall Nr 0.35 Nr 0.12
pipe over 55mm but n e 110mm dia; make good; half brick wall Nr 0.46 Nr 0.21
pipe n e 55mm dia; make good; one brick wall Nr 0.51 Nr 0.26
pipe over 55mm but n e 110mm dia; make good; one brick wall Nr 0.62 Nr 0.39
pipe n e 55mm dia; make good; 100mm thick block wall Nr 0.35 Nr 0.12
pipe over 55mm but n e 110mm dia; make good; 100mm thick block wall Nr 0.46 Nr 0.21
pipe n e 55mm dia; make good; 150mm thick block wall Nr 0.51 Nr 0.26
pipe over 55mm but n e 110mm dia; make good; 150mm thick block wall Nr 0.62 Nr 0.39
weather or angle horizontal; face 50mm wide m 0.16 ft 0.05
weather or angle horizontal; face 100mm wide m 0.28 ft 0.08
edge of flashing m 0.25 ft 0.08
wedge horizontal; half brick thick m 0.38 ft 0.12
wedge horizontal; one brick thick m 0.51 ft 0.16
wedge horizontal; one and a half brick thick m 0.64 ft 0.19
vertical; n e 225mm wide contact surface m2 0.82 ft2 0.08
raking; n e 225mm wide contact surface m2 0.82 ft2 0.08
horizontal; n e 225mm wide contact surface m2 0.78 ft2 0.07
stepped; n e 225mm wide contact surface m2 0.88 ft2 0.08
cavity tray; n e 225mm wide contact surface m2 0.97 ft2 0.09
vertical; over 225mm wide contact surface m2 0.75 ft2 0.07
raking; over 225mm wide contact surface m2 0.75 ft2 0.07
horizontal; over 225mm wide contact surface m2 0.73 ft2 0.07
stepped; over 225mm wide contact surface m2 0.81 ft2 0.08
cavity tray; over 225mm wide contact surface m2 0.91 ft2 0.09
horizontal; 64mm wide m 0.11 ft 0.03
horizontal; 178mm wide m 0.15 ft 0.04
vertical; half brick wall m 0.18 ft 0.06
vertical; one brick wall m 0.32 ft 0.10
vertical; one and a half brick wall m 0.44 ft 0.14
vertical; 100mm block wall m 0.18 ft 0.06
vertical; 140mm block wall m 0.32 ft 0.10
vertical; 150mm block wall m 0.32 ft 0.10
vertical; 215mm block wall m 0.44 ft 0.14
extra; designed joint sealing add face m 0.08 ft 0.03
metal unit; single or composite window; irrespective of wall thickness Nr 2.03 Nr 4.13
metal unit; single pressed metal door; irrespective of wall thickness Nr 4.07 Nr 16.53
metal unit; pair of pressed metal doors; irrespective of wall thickness Nr 8.13 Nr 66.12
extra; metal unit; pointing one side in mastic m 0.54 ft 0.16
air brick; 225 x 150mm; one brick wall; Nr 0.22 Nr 0.05
air brick; 225 x 150mm; one and a half brick wall; Nr 0.30 Nr 0.09Build in; one end Fixing cramp galvanised iron; 250 girth, once bent; one end screwed to
softwood; Nr 0.06 Nr 0.00
Form fillet; cement mortar (1:3)
Form hole or build in;
Pointing; cement mortar (1:3)
Build in; damp proof course; bedded in cement mortar(1:4); allow for laps, ends and angles;
Build in; designed expansion joint; 12 thick jointing material; sealing one face with 12 x 25 deep polysulphide sealant include all associated cutting etc
Form cavity in hollow wall
Form cavity between wall and other work
Build in; cut and pin lug or plug and screw to brickwork
Build in; bedded and pointed in cement mortar (1:4)
Build in; reinforcing joint
vertical; engineering brickwork; general surface m2 0.09 ft2 0.01
vertical; facing brickwork; general surface m2 0.09 ft2 0.01
vertical; concrete blockwork; general surface m2 0.07 ft2 0.01
vertical; aerated blockwork; general surface m2 0.07 ft2 0.01
vertical; engineering brickwork; general surface m2 0.12 ft2 0.01
vertical; facing brickwork; general surface 0.12
vertical; concrete blockwork; general surface m2 0.12 ft2 0.01
vertical; aerated blockwork; general surface 0.12
Remove effloresence with dry brush;
Wash down and clean with approved cleaning agent,
Clean
318
wall; engineering brickwork; fill joint m2 0.13 ft2 0.01
wall; facing brickwork; fill joint 0.13wall; concrete blockwork; fill joint m2 0.07 ft2 0.01
wall; aerated blockwork; fill joint 0.07
wall; brickwork; joint and point with plain mortar m 0.57 ft 0.17
wall; brickwork; joint and point with coloured mortar m 0.57 ft 0.17
wall; blockwork, joint and point with approved mortar m 0.37 ft 0.11
pipe n e 55mm dia; m 0.84 ft 0.26
extra; for making good facing brickwork; pipe n e 55mm dia m 0.13 ft 0.04
pipe over 55 not n e 110mm dia m 1.17 ft 0.36
extra; for making good facing brickwork; pipe over 55 but n e 110mm dia m 0.26 ft 0.08
wall; n e 0.10 m2, half brick thick Nr 0.41 Nr 0.16
wall; over 0.10 but n e 0.25 m2, half brick thick Nr 0.50 Nr 0.25
wall; over 0.25 but n e 0.50 m2, half brick thick Nr 0.61 Nr 0.38
wall; n e 0.10 m2, one brick thick Nr 0.52 Nr 0.27
wall; over 0.10 but n e 0.25 m2, one brick thick Nr 0.70 Nr 0.49
wall; over 0.25 but n e 0.50 m2, one brick thick Nr 0.79 Nr 0.63
pipe n e 55mm dia; half brick wall Nr 0.68 Nr 0.46
pipe over 55 nut n e 110mm dia; half brick wall Nr 0.68 Nr 0.46
pipe n e 55mm dia; one brick wall Nr 0.87 Nr 0.75
pipe over 55 nut n e 110mm dia; one brick wall Nr 0.87 Nr 0.75
pipe n e 55mm dia; 100mm thick block wall nr 0.68 Nr 0.46
pipe over 55 nut n e 110mm dia; 100mm thick block wall wall nr 0.68 Nr 0.46
pipe n e 55mm dia; 140mm thick block wall m 0.87 ft 0.26
pipe over 55 nut n e 110mm dia; 140mm thick block wall wall nr 0.87 Nr 0.75
pipe n e 55mm dia; 150mm thick block wall m 0.95 ft 0.29
pipe over 55 nut n e 110mm dia; 150mm thick block wall wall nr 0.95 Nr 0.90
pipe support; pipe n e 55mm dia Nr 0.24 Nr 0.06
pipe support; pipe over 55 but n e 110mm dia Nr 0.36 Nr 0.13
Rake out joint
Cut hole; circular; making good
Repair
Cut and pin, make good
Cut chase
Cut hole; square or rectangular; make good
wall; half brick thick;engineering brickwork m2 0.78 ft2 0.07wall; half brick thick; facing brickwork m2 0.78 ft2 0.07wall; one brick thick; engineering brickwork m2 0.98 ft2 0.09wall; one brick thick; facing brickwork m2 0.98 ft2 0.09wall; half brick thick;engineering brickwork m2 1.75 ft2 0.16wall; half brick thick; facing brickwork m2 1.75 ft2 0.16wall; one brick thick; engineering brickwork m2 2.15 ft2 0.20wall; one brick thick; facing brickwork m2 2.15 ft2 0.20
wall; 100mm thick, concrete blockwok m2 0.35 ft2 0.03
wall; 100mm thick, aerated blockwork m2 0.35 ft2 0.03
wall; 140mm thick, aerated blockwork m2 0.37 ft2 0.03
wall; 150mm thick, concrete blockwork m2 0.37 ft2 0.03
wall; 215mm thick; concrete blockwork m2 0.40 ft2 0.04
wall; 215mm thick; aerated blockwork m2 0.40 ft2 0.04
wall; 100mm thick, concrete blockwok m2 0.82 ft2 0.08
wall; 100mm thick, aerated blockwork m2 0.82 ft2 0.08
wall; 140mm thick, aerated blockwork m2 0.86 ft2 0.08
wall; 150mm thick, concrete blockwork m2 0.86 ft2 0.08
wall; 215mm thick; concrete blockwork m2 0.91 ft2 0.08
wall; 215mm thick; aerated blockwork m2 0.91 ft2 0.08
Clean off blocks and clean opening, and select blocks to match existing, lay with approved mortar, jointing and pointing to match existing
Cut out defective blockwork, dispose of material or set aside; clean opening exposed
Replace
Cut out defective brickwork; dispose of material or set aside; clean opening exposed
Clean off bricks, select bricks to match existing; relay with approved mortar, jointing and pointing to match existing
319
Q.2.1.6 Specialist Linings
BRICKWORK
wall; half brick thick m2 1.12 ft2 0.10
facework one side; half brick thick m2 1.33 ft2 0.12
facework both sides; half brick thick m2 1.56 ft2 0.15
extra over; acid resisting brickwork; half brick thick; skin of hollow wall m2 0.11 ft2 0.01
extra over; acid resisting brickwork; half brick thick; building against other work m2 0.12 ft2 0.01
wall; one brick thick m2 1.92 ft2 0.18
facework one side; one brick thick m2 2.11 ft2 0.20
facework both sides; one brick thick m2 2.35 ft2 0.22
extra over; acid resisting brickwork; one brick thick; skin of hollow wall m2 0.12 ft2 0.01
extra over; acid resisting brickwork; one brick thick; building against other work m2 0.12 ft2 0.01
wall; one and a half brick thick m2 2.38 ft2 0.22
facework one side; one and a half brick thick m2 2.48 ft2 0.23
facework both sides; one and a half brick thick m2 2.69 ft2 0.25
extra over; acid resisting brickwork; one and a half brick thick; skin of hollow wall m2 0.17 ft2 0.02
extra over; acid resisting brickwork; one and a half brick thick; building against other workm2 0.17 ft2 0.02
isolated pier; half brick thick m2 1.23 ft2 0.11
facework all sides; half brick thick m2 1.45 ft2 0.13
isolated pier; one brick thick m2 2.08 ft2 0.19
facework all sides; one brick thick m2 2.28 ft2 0.21
isolated pier; one and a half brick thick m2 2.29 ft2 0.21
facework all sides; one and a half brick thick m2 2.55 ft2 0.24
isolated casing; half brick thick m2 1.23 ft2 0.11
isolated casing; one brick thick m2 2.08 ft2 0.19
isolated casing; one and a half brick thick m2 2.29 ft2 0.21
projection; 225mm wide; half brick thick m 0.35 ft 0.11
projection; 337mm wide; half brick thick m 0.45 ft 0.14
projection; 440mm wide; half brick thick m 0.59 ft 0.18
projection; 552mm wide; half brick thick m 0.71 ft 0.22
Percentage adjustment for each additional half brick width; projection %
projection; 225mm wide; one brick thick m 0.65 ft 0.20
projection; 337mm wide; one brick thick m 0.82 ft 0.25
projection; 440mm wide; one brick thick m 1.06 ft 0.32
projection; 552mm wide; one brick thick m 1.23 ft 0.37
Percentage adjustment for each additional one brick width; projection %
projection; 225mm wide; one and a half brick thick m 0.93 ft 0.28
projection; 337mm wide; one and a half brick thick m 1.12 ft 0.34
projection; 440mm wide; one and a half brick thick m 1.54 ft 0.47
projection; 552mm wide; one and a half brick thick m 1.74 ft 0.53
Norm Hrs. IIMPERIALSPECIALIST LININGS
Lay; acid resisting brickwork; bedded, jointed and pointed with approved mortar
New Work
Norm Hrs. METRIC
320
wall; half brick thick m2 1.05 ft2 0.10
facework one side; half brick thick m2 1.18 ft2 0.11
facework both sides; half brick thick m2 1.33 ft2 0.12
extra over; refractory brickwork; half brick thick; skin of hollow wall m2 0.14 ft2 0.01
extra over; refractory brickwork; half brick thick; building against other work m2 0.14 ft2 0.01
wall; one brick thick m2 1.86 ft2 0.17
facework one side; one brick thick m2 2.18 ft2 0.20
facework both sides; one brick thick m2 2.39 ft2 0.22
extra over; refractory brickwork; half brick thick; skin of hollow wall m2 0.14 ft2 0.01
extra over; refractory brickwork; half brick thick; building against other work m2 0.14 ft2 0.01
wall; one and a half brick thick m2 3.89 ft2 0.36
facework one side; one and a half brick thick m2 4.02 ft2 0.37
facework both sides; one and a half brick thick m2 4.15 ft2 0.39
extra over; refractory brickwork; half brick thick; skin of hollow wall m2 0.14 ft2 0.01
extra over; refractory brickwork; half brick thick; building against other work m2 0.14 ft2 0.01
isolated pier; half brick thick m2 1.54 ft2 0.14
facework all sides; half brick thick m2 1.67 ft2 0.16
isolated pier; one brick thick m2 2.84 ft2 0.26
facework all sides;one brick thick m2 2.97 ft2 0.28
isolated pier; one and a half brick thick m2 3.82 ft2 0.36
facework all sides; one and a half brick thick m2 3.95 ft2 0.37
isolated casing; half brick thick m2 1.54 ft2 0.14
isolated casing; one brick thick m2 2.84 ft2 0.26
isolated casing; one and a half brick thick m2 3.82 ft2 0.36
projection; 225mm wide; half brick thick m 0.44 ft 0.14
projection; 337mm wide; half brick thick m 0.57 ft 0.17
projection; 440mm wide; half brick thick m 0.73 ft 0.22
projection; 552mm wide; half brick thick m 0.87 ft 0.27
Percentage adjustment for each additional half brick width; projection %
bonding end; half brick thick; to existing brickwork m 0.19 ft 0.06
projection; 225mm wide; one brick thick m 0.84 ft 0.25
projection; 337mm wide; one brick thick m 1.05 ft 0.32
projection; 440mm wide; one brick thick m 1.33 ft 0.41
projection; 552mm wide; one brick thick m 1.55 ft 0.47
Percentage adjustment for each additional one brick width %
bonding end; one brick thick; to existing brickwork m 0.30 ft 0.09
projection; 225mm wide; one and a half brick thick m 1.20 ft 0.37
projection; 337mm wide; one and a half brick thick m 1.48 ft 0.45
projection; 440mm wide; one and a half brick thick m 1.96 ft 0.60
projection; 552mm wide; one and a half brick thick m 2.22 ft 0.68
bonding end; one and a half brick thick; to existing brickwork m 0.41 ft 0.12fire proofing vessel; curved radius n e 1m; half brick thick m2 1.42 ft2 0.13
fire proofing vessel; curved radius over 1 but n e 2m; half brick thick m2 1.42 ft2 0.13
fire proofing vessel; curved radius over 2 but n e 4m; half brick thick m2 1.30 ft2 0.12
fire proofing vessel; curved radius over 4m; half brick thick m2 1.21 ft2 0.11
fire proofing vessel; curved diminishing radius n e 1m; half brick thick m2 1.58 ft2 0.15
fire proofing vessel; curved diminishing radius over 1 but n e 2m; half brick thick
m2 1.58 ft2 0.15
fire proofing vessel; curved diminishing radius over 2 but n e 4m; half brick thick
m2 1.44 ft2 0.13
extra for fair face and flush jointing; fire proofing vessel; half brick thick m2 0.00 ft2 0.00
percentage adjustment; half brick thick; fire proofing internally %
fire proofing vessel; curved radius n e 1m; one brick thick m2 2.22 ft2 0.21
fire proofing vessel; curved radius over 1 but n e 2m; one brick thick m2 2.22 ft2 0.21
fire proofing vessel; curved radius over 2 but n e 4m; one brick thick m2 2.14 ft2 0.20
fire proofing vessel; curved radius over 4m; one brick thick m2 1.98 ft2 0.18
fire proofing vessel; curved diminishing radius n e 1m; one brick thick m2 2.38 ft2 0.22
fire proofing vessel; curved diminishing radius over 1 but n e 2m; one brick thick
m2 2.38 ft2 0.22
fire proofing vessel; curved diminishing radius over 2 but n e 4m; one brick thick
m2 2.29 ft2 0.21
extra for fair face and flush jointing; fire proofing vessel; one brick thick m2 0.37 ft2 0.03
percentage adjustment; one brick thick; fire proofing internally %
fire proofing vessel; curved radius n e 1m; one and a half brick thick m2 2.33 ft2 0.22
fire proofing vessel; curved radius over 1 but n e 2m; one and a half brick thick
m2 2.33 ft2 0.22
fire proofing vessel; curved radius over 2 but n e 4m; one and a half brick thick
m2 2.20 ft2 0.21
fire proofing vessel; curved radius over 4m; one and a half brick thick m2 2.06 ft2 0.19
fire proofing vessel; curved diminishing radius n e 1m; one and a half brick thick
m2 2.44 ft2 0.23
fire proofing vessel; curved diminishing radius over 1 but n e 2m; one and a half brick thick
m2 2.44 ft2 0.23
fire proofing vessel; curved diminishing radius over 2 but n e 4m; one and a half brick thick
m2 2.30 ft2 0.21
percentage adjustment; one and a half brick thick; fire proofing internally %
Lay; refractory brickwork; jointed and pointed with approved mortar
321
fire proofing vessel; curved radius n e 1m; 100mm thick m2 1.42 ft2 0.13fire proofing vessel; curved radius over 1 but n e 2m; 100mm thick m2 1.42 ft2 0.13fire proofing vessel; curved radius over 2 but n e 4m; 100mm thick m2 1.30 ft2 0.12fire proofing vessel; curved radius over 4m; 100mm thick m2 1.21 ft2 0.11fire proofing vessel; curved diminishing radius n e 1m; 100mm thick m2 1.58 ft2 0.15fire proofing vessel; curved diminishing radius over 1 but n e 2m; 100mm thick
m2 1.58 ft2 0.15fire proofing vessel; curved diminishing radius over 2 but n e 4m; 100mm thick
m2 1.44 ft2 0.13extra for fair face and flush jointing; fire proofing vessel; 100mm thick m2 0.00 ft2 0.00percentage adjustment; 100mm thick; fire proofing internally %
fire proofing vessel; curved radius n e 1m; 140mm thick m2 2.22 ft2 0.21fire proofing vessel; curved radius over 1 but n e 2m; 140mm thick m2 2.22 ft2 0.21fire proofing vessel; curved radius over 2 but n e 4m; 140mm thick m2 2.14 ft2 0.20fire proofing vessel; curved radius over 4m; 140mm thick m2 1.98 ft2 0.18fire proofing vessel; curved diminishing radius n e 1m; 140mm thick m2 2.38 ft2 0.22fire proofing vessel; curved diminishing radius over 1 but n e 2m; 140mm thick m2 2.38 ft2 0.22
fire proofing vessel; curved diminishing radius over 2 but n e 4m; 140mm thick m2 2.29 ft2 0.21
extra for fair face and flush jointing; fire proofing vessel; 140mm thick m2 0.37 ft2 0.03
percentage adjustment; 140mm thick; fire proofing internally %fire proofing vessel; curved radius n e 1m; m2 1.42 ft2 0.13fire proofing vessel; curved radius over 1 but n e 2m; m2 1.42 ft2 0.13fire proofing vessel; curved radius over 2 but n e 4m; m2 1.30 ft2 0.12fire proofing vessel; curved radius over 4m; m2 1.21 ft2 0.11fire proofing vessel; curved diminishing radius n e 1m; m2 1.58 ft2 0.15fire proofing vessel; curved diminishing radius over 1 but n e 2m; m2 1.58 ft2 0.15fire proofing vessel; curved diminishing radius over 2 but n e 4m; m2 1.44 ft2 0.13percentage adjustment; tiling; fire proofing internally m2 0.00 ft2 0.00fire proofing vessel; curved radius n e 1m; m2 1.42 ft2 0.13fire proofing vessel; curved radius over 1 but n e 2m; m2 1.42 ft2 0.13fire proofing vessel; curved radius over 2 but n e 4m; m2 1.30 ft2 0.12fire proofing vessel; curved radius over 4m; m2 1.21 ft2 0.11fire proofing vessel; curved diminishing radius n e 1m; m2 1.58 ft2 0.15fire proofing vessel; curved diminishing radius over 1 but n e 2m; m2 1.58 ft2 0.15fire proofing vessel; curved diminishing radius over 2 but n e 4m; m2 1.44 ft2 0.13percentage adjustment; lining; fire proofing internally %fire proofing vessel; curved radius n e 1m; m2 1.42 ft2 0.13fire proofing vessel; curved radius over 1 but n e 2m; m2 1.42 ft2 0.13fire proofing vessel; curved radius over 2 but n e 4m; m2 1.30 ft2 0.12fire proofing vessel; curved radius over 4m; m2 1.21 ft2 0.11fire proofing vessel; curved diminishing radius n e 1m; m2 1.58 ft2 0.15fire proofing vessel; curved diminishing radius over 1 but n e 2m; m2 1.58 ft2 0.15fire proofing vessel; curved diminishing radius over 2 but n e 4m; m2 1.44 ft2 0.13percentage adjustment to fire proofing rates for fire proofing internally %
Lay; refractory tiling; jointed and pointed with approved mortar
Lay; refractory blockwork; jointed and pointed with approved mortar
Apply refractory lining; fabric reinforcement
Apply refractory mortar
vertically or curved; acid resisting brickwork m2 0.09 ft2 0.01
vertically or curved; refractory brickwork m2 0.09 ft2 0.01
vertically or curved; refractory blockwork m2 0.05 ft2 0.00
vertically or curved; refractory tiling m2 1.13 ft2 0.11
vertically or curved; refractory lining m2 0.09 ft2 0.01
vertically or curved; acid resisting brickwork m2 0.12 ft2 0.01
vertically or curved; refractory brickwork m2 0.12 ft2 0.01
vertically or curved; refractory blockwork m2 0.08 ft2 0.01
vertically or curved; refractory tiling m2 0.60 ft2 0.06
vertically or curved; refractory lining m2 0.12 ft2 0.01
Clean
Remove effloresence with dry brush;
Wash down and clean with approved cleaning agent,
322
wall; vertical or curved; acid resisting brickwork, m2 0.37 ft2 0.03wall; vertical or curved; refractory brickwork, m2 0.37 ft2 0.03wall; vertical or curved; refractory blockwork, m2 0.27 ft2 0.03wall; vertical or curved; refractory tiling, m2 0.47 ft2 0.04wall; vertical or curved; acid resisting brickwork, m 0.15 ft 0.05
wall; vertical or curved; refractory brickwork, m 0.15 ft 0.05
wall; vertical or curved; refractory blockwork, m 0.15 ft 0.05
wall; vertical or curved; refractory tiling, m 0.15 ft 0.05
Repair crack in refractory lining; approved filling material wall; vertical or curved; refractory lmortar; m 0.26 ft 0.08
wall; n e 0.10 m2, half brick thick Nr 0.41 Nr 0.41
wall; ; over 0.10 but n e 0.25 m2, half brick thick Nr 0.50 Nr 0.50
wall; over 0.25 but n e 0.50 m2, half brick thick Nr 0.61 Nr 0.61
wall; n e 0.10 m2, one brick thick Nr 0.52 Nr 0.52
wall; over 0.10 but n e 0.25 m2, one brick thick Nr 0.70 Nr 0.70
wall; over 0.25 but n e 0.50 m2, one brick thick Nr 0.79 Nr 0.79
wall; ; n e 0.10 m2, half brick thick Nr 0.41 Nr 0.41
wall; over 0.10 but n e 0.25 m2, half brick thick Nr 0.50 Nr 0.50
wall; over 0.25 but n e 0.50 m2, half brick thick Nr 0.61 Nr 0.61
wall; n e 0.10 m2, one brick thick Nr 0.52 Nr 0.52
wall; over 0.10 but n e 0.25 m2, one brick thick Nr 0.70 Nr 0.70
wall; over 0.25 but n e 0.50 m2, one brick thick Nr 0.79 Nr 0.79
wall; n e 0.10 m2, 100mm block wall Nr 0.41 Nr 0.41
wall, over 0.10m2 but n e 0.25 m2, 100mm block wall Nr 0.50 Nr 0.50
wall; over 0.25m2; n e 0.50 m2, 100mm block wall Nr 0.61 Nr 0.61
wall; n e 0.10 m2, 140mm block wall Nr 0.52 Nr 0.52
wall, over 0.10 but n e 0.25 m2, 140mm block wall Nr 0.70 Nr 0.70
wall; over 0.25 but n e 0.50 m2, 140mm block wall Nr 0.79 Nr 0.79
wall; n e 0.10 m2, Nr 0.41 Nr 0.41
wall; over 0.10 but n e 0.25 m2, Nr 0.41 Nr 0.41
wall; over 0.25 but n e 0.50 m2, Nr 0.41 Nr 0.41
wall; area n e 0.10m2 m2 1.15 ft2 0.11wall; area over 0.10 but n e 0.50m2 m2 1.50 ft2 0.14
wall; area over 0.50 but ne 1.00m2 m2 1.85 ft2 0.17
Extra over cut out and reuse refractory material percentage additional curved; %
Repair
Rake out joint
Rake out joint; fill joint and point with approved material
Cut out defective refractory lining material, prepare surface of background, and apply thickness of approved material to finish flush with existing
Carefully cut out loose or defective acid resisting brickwork, clean off bricks, clean opening exposed, reuse bricks, laid and jointed with approved mortar, and pointing to match existing
Carefully cut out loose or defective refractory brickwork, clean off bricks, clean opening exposed, reuse bricks, laid and jointed with approved mortar, and pointing to match existing
Carefully cut out loose or defective refractory blockwork, clean off bricks, clean opening exposed, reuse bricks, laid and jointed with approved mortar, and pointing to match existing
Carefully cut out loose or defective refractory tiling, clean off tiles, clean opening exposed, reuse tiles, laid and jointed with approved mortar, and pointing to match existing
Removal of refractory material only, for replacemen t use NEW rates
wall; vertical or curved; half brick thick, m2 1.67 ft2 0.16wall; vertical or curved; one brick thick, m2 3.05 ft2 0.28
hollow wall; vertical or curved; half brick skin, m2 1.67 ft2 0.16
hollow wall; vertical or curved; one brick skin, m2 3.05 ft2 0.28
wall; vertical or curved; half brick thick, m2 1.67 ft2 0.16
wall; vertical or curved; one brick thick, m2 3.05 ft2 0.28
hollow wall; vertical or curved; half brick skin, m2 1.67 ft2 0.16
hollow wall; vertical or curved; one brick skin, m2 3.05 ft2 0.28
wall; vertical or curved; 100mm thick m2 1.67 ft2 0.16
wall; vertical or curved; 140mm thick, m2 3.05 ft2 0.28wall, vertical or curved; over 1.00m2 m2 0.45 ft2 0.04
Cut out defective refractory tiling material, prepare surface of background,
Cut out defective refractory brickwork material and remove, clean opening exposed.
Cut out defective refractory blockwork material and remove, clean opening exposed.
Cut out defective acid resisting brickwork material and remove, clean opening exposed.
Replace
323
Q.2.1.7 Surface Treatments
Surface Treatments includes for surface application s to surfaces other than for asthetics such as fire proofingSee also - Building - Surface finishes
See also Masonry for brickwork fireproofing
vertical; 20mm thick three coat covering; m2 0.45 ft2 0.04
vertical; 25mm thick three coat covering; m2 0.47 ft2 0.04
vertical; 40mm thick four coat covering; m2 0.63 ft2 0.06
horizontal; 13mm thick one coat covering; m2 0.31 ft2 0.03
horizontal; 20mm thick two coat covering; m2 0.45 ft2 0.04
horizontal; 30mm thick three coat covering; m2 0.57 ft2 0.05
vertical; 13mm thick one coat covering; m2 0.31 ft2 0.03
vertical; 20mm thick two coat covering; m2 0.45 ft2 0.04
vertical; 30mm thick three coat covering; m2 0.57 ft2 0.05
forming; vertical or horizontal; penetration; pipe n e 55mm dia nr 0.25 Nr 0.06
forming;vertical or horizontal; penetration; pipe over 55 n e 100dia nr 0.36 Nr 0.13
horizontal on slab; 500 grade m2 0.09 ft2 0.01
horizontal on slab; 1000 grade m2 0.10 ft2 0.01
horizontal on slab; heavy duty grade m2 0.12 ft2 0.01
vertical dressed up face of concrete or masonry; 1000 grade m2 0.17 ft2 0.02
forming; vertical or horizontal; penetration; pipe n e 55mm dia nr 0.25 Nr 0.06
forming; vertical or horizontal; penetration; pipe over 55 n e 100dia nr 0.36 Nr 0.13vertical four faces; 25mm thick; 2 hour fire protection rating;n e 600mm girth
m 0.69 ft 0.21
vertical four faces; 25mm thick; 2 hour fire protection rating; over 600mm but n e 1200 girth
m 0.83 ft 0.25
vertical four faces; 25mm thick; 2 hour fire protection rating; over 1200mm but n e 1800 girth
m 1.16 ft 0.35
vertical four faces; 55mm thick; 4 hour fire protection rating;n e 600mm girth
m 0.83 ft 0.25
vertical four faces; 55mm thick; 4 hour fire protection rating; over 600mm but n e 1200 girth
m 1.02 ft 0.31
vertical four faces; 55mm thick; 4 hour fire protection rating; over 1200mm but n e 1800 girth
m 1.39 ft 0.42
3 faces; 30mm thick; 2 hour fire protection rating n e 600mm girth m 0.56 ft 0.17
3 faces; 30mm thick; 2 hour fire protection rating; over 600mm but n e 1200 girth
m 0.69 ft 0.21
3 faces; 30mm thick; 2 hour fire protection rating; over 1200mm but n e 1800 girth
m 0.83 ft 0.25
3 faces; 60mm thick; 4 hour fire protection rating; n e 600mm girth m 0.69 ft 0.213 faces; 60mm thick; 4 hour fire protection rating; over 600mm but n e 1200 girth m 0.83 ft 0.253 faces; 60mm thick; 4 hour fire protection rating; over 1200mm but n e 1800 girth m 1.02 ft 0.31
See also Building - surface finishes
For surface treatment - steelwork
Apply intumescent coating; two coats; steelwork structure; over 300mm girth m2 0.99 ft2 0.09steelwork structure; soffit over 300mm girth m2 0.29 ft2 0.03
Apply; epoxy resin sealer; two coats; concrete floor; over 300mm girth m2 0.19 ft2 0.02
Apply; floor hardener and dust proofer; two coats; concrete floor; over 300mm girth m2 0.24 ft2 0.02Apply cement paint; two coats brickwork or blockwork wall; over 300mm girth m2 0.31 ft2 0.03
brickwork or blockwork wall; over 300mm girth m2 0.50 ft2 0.05
SURFACE TREATMENTS
Install gypsum board; column casing; fixed with adhesive; joints pointed in adhesive
Install gypsum board; beam lining; fixed with adhesive; joints pointed in adhesive
Apply waterproof rendering; prepare surface of concrete, brickwork or blockwork; steel trowelled
Labour Norm Hrs.
Labour Norm Hrs.
New Work
Apply mastic asphalt tanking; prepare surface of concrete, or other background
Install flexible sheet tanking, lapped joints,
Apply; primer one coat; two undercoats and oil gloss paint one finishing coat;
See Repair - Touch up, assuming offsite preparatio n
Apply sealer one coat; external grade emulsion paint two coats;
324
Clean down waterproof rendering; approved cleaning agent vertical; surface over 300mm girth, m2 0.02 ft2 0.00
horizontal; surface over 300mm girth, m2 0.02 ft2 0.00
vertical; surface over 300mm girth, m2 0.02 ft2 0.00Clean down of sheet tanking; approved cleaning agent horizontal; surface over 300mm girth, m2 0.05 ft2 0.00
vertical; surface over 300mm girth, m2 0.05 ft2 0.00
column; fire boarding, m2 0.03 ft2 0.00
beam; fire boarding, m2 0.03 ft2 0.00
column; general surface over 300mm girth m2 0.03 ft2 0.00
beam; general surface over 300mm girth m2 0.03 ft2 0.00
wall; general surface over 300mm girth m2 0.03 ft2 0.00
See also Masonry for clean down surface of brickwor k
Clean
Clean down intumescent application covering; approved cleaning agent
Clean down fire proofing; approved cleaning agent
Clean down cement paint; approved cleaning agent;
Clean down of mastic asphalt tanking; approved cleaning agent
vertical; in area n e 1.00m2 m2 0.50 ft2 0.05
vertical; m 0.15 ft 0.05
vertical; in area n e 1.00m2 m2 0.50 ft2 0.05
horizontal; in area n e 1.00m2 m2 0.50 ft2 0.05
penetration; pipe n e 55mm dia nr 0.25 Nr 0.06
penetration; pipe over 55 but n e 110mm dia nr 0.37 Nr 0.14
vertical m 0.17 ft 0.05
horizontal m 0.17 ft 0.05
vertical; in area n e 1.00m2 m2 0.50 ft2 0.05
horizontal; in area n e 1.00m2 m2 0.50 ft2 0.05
penetration; pipe n e 55mm dia nr 0.25 Nr 0.06
penetration; pipe over 55 but n e 110mm dia nr 0.37 Nr 0.14
vertical m 0.17 ft 0.05
horizontal m 0.17 ft 0.05
column; in area n e 1.00m2 m2 0.15 ft2 0.01
beam; in area n e 1.00m2 m2 0.15 ft2 0.01
vertical m 0.16 ft 0.05
horizontal m 0.16 ft 0.05
structural steelwork; in area n. e.1.00m2 m2 1.25 ft2 0.12
surface, soffit m2 0.19 ft2 0.02
vertical; structural steel member m2 0.25 ft2 0.02
horizontal; structural steel member m2 0.25 ft2 0.02
vertical or secondary steel member m2 0.27 ft2 0.03
horizontal; secondary steel member m2 0.27 ft2 0.03
horizontal; open grid flooring m2 0.23 ft2 0.02
horizontal; chequerplate flooring m2 0.21 ft2 0.02
handrailing m 0.14 ft 0.04
staircase m2 2.00 ft2 0.19
ladder m 0.30 ft 0.09
concrete column and beam; in area less than 5 m2 m2 0.29 ft2 0.03concrete column and beam; in area over 5m2 m2 0.24 ft2 0.02
vertical m2 0.22 ft2 0.02
horizontal m2 0.22 ft2 0.02
vertical m2 0.22 ft2 0.02
Repair damage area; finish steelwork; clean surface; approved cleaning agent; apply zinc primer one coat; decorative paint two coats and sealer
Repair damaged area; sheet tanking; approved material to match existing
Repair damaged area; mastic asphalt tanking; approved material to match existing
Repair
Repair damaged area; waterproof rendering; approved material to match existing
Repair crack; waterproof rendering; approved material to match existing
Repair crack; mastic asphalt tanking; approved material to match existing
Repair crack; sheet tanking; approved material to match existing
Repair damaged area; intumescence paint application; approved material to match existing;
Repair damaged area; finish to permanent formwork; apply approved painting system
Repair damaged area; surface of fire protection boarding; approved material to match existing; finishing flush.
Carefully clean out damaged joint between fire boarding; apply approved jointing compound to reform joint
Repair damaged area; painted finish; clean surface; approved cleaning agent; apply reactive silicone primer one coat; of acrylic polymer topcoat one coat,
Repair damaged area; painted surface of concrete, clean surface; approved cleaning agent; apply approved painting system.
Repair damaged area; painted surface of brickwork or blockwork, clean surface ; approved cleaning agent; apply approved painting system
325
Removal of existing applications only, For replacem ent use NEW rates
vertical; 20mm thick; m2 0.09 ft2 0.01vertical; 25mm thick; m2 0.09 ft2 0.01vertical; 40mm thick; m2 0.09 ft2 0.01
horizontal; 13mm thick covering; m2 0.14 ft2 0.01
horizontal; 20mm thick covering; m2 0.15 ft2 0.01
horizontal; 30mm thick covering; m2 0.16 ft2 0.01
vertical; 13mm thick covering; m2 0.14 ft2 0.01
vertical; 20mm thick covering; m2 0.15 ft2 0.01
vertical; 30mm thick covering; m2 0.16 ft2 0.01
horizontal on slab; 500 grade m2 0.14 ft2 0.01
horizontal on slab; 1000 grade m2 0.15 ft2 0.01
horizontal on slab; heavy duty grade m2 0.16 ft2 0.01
vertical; 1000 grade m2 0.15 ft2 0.01
column; four faces; 25mm thick; m2 0.06 ft2 0.01
column; four faces; 55mm thick; m2 0.07 ft2 0.01
beam; three faces; 30mm thick; m2 0.06 ft2 0.01
beam; three faces; 60mm thick; m2 0.07 ft2 0.01
steelwork surface, over 300mm girth m2 0.15 ft2 0.01
vertical; structural steel member m2 0.12 ft2 0.01
horizontal; structural steel member m2 0.12 ft2 0.01
vertical; secondary steel member m2 0.12 ft2 0.01
horizontal; secondary steel member m2 0.12 ft2 0.01
horizontal; open grid flooring m2 0.05 ft2 0.00
horizontal; chequerplate flooring m2 0.16 ft2 0.01
handrailing m 0.08 ft 0.02
staircase nr 0.26 Nr 0.07
ladder nr 0.18 Nr 0.03
soffit of permanent formwork m2 0.22 ft2 0.02
vertical m2 0.12 ft2 0.01
horizontal m2 0.12 ft2 0.01Strip off paint system, surface of brickwork or blockwork wall; prepare backgound to receive new
vertical m2 0.12 ft2 0.01
Carefully remove and dispose; mastic asphalt tanking; concrete; prepare background to receive new
Carefully remove and dispose; sheet tanking; to concrete or brickwork or blockwork; prepare background to receive new
Carefully remove and dispose; fire board casing; to steelwork, prepare background to receive new.
Replace
Strip off paint system; surface of concrete, prepare background to receive new
Carefully remove and dispose; waterproof rendering; brickwork or blockwork; prepare backgound to receive new
Strip off paint system; surface of metalwork; prepare background to receive new
Carefully remove and dispose; intumescent paint application; clean down background and prepare surface to receive new.
Strip off and dispose paint system, surface of steelwork; prepare background to receive new
326
Q.2.1.8 Drainage
EARTHWORKS
By hand
n e 250mm average (ave) depth; pipe n e 200mm dia m 0.27 ft 0.08
500mm ave depth; pipe n e 200mm dia m 0.27 ft 0.08
750mm ave depth; pipe n e 200mm dia m 0.55 ft 0.17
1.00m ave depth; pipe n e 200mm dia m 0.75 ft 0.23
1.25m ave depth; pipe n e 200mm dia m 0.91 ft 0.28
1.50m ave depth; pipe n e 200mm dia m 1.34 ft 0.41
1.70m ave depth; pipe n e 200mm dia m 1.56 ft 0.48
2.00m ave depth; pipe n e 200mm dia m 1.79 ft 0.55
2.25m ave depth; pipe n e 200mm dia m 3.16 ft 0.96
2.50m ave depth; pipe n e 200mm dia m 3.51 ft 1.07
2.75m ave depth; pipe n e 200mm dia m 3.86 ft 1.18
3.00m ave depth; pipe n e 200mm dia m 4.22 ft 1.29
3.25m ave depth; pipe n e 200mm dia m 5.47 ft 1.67
3.50m ave depth; pipe n e 200mm dia m 5.88 ft 1.79
3.75m ave depth; pipe n e 200mm dia m 6.01 ft 1.83
4.00m ave depth; pipe n e 200mm dia m 6.40 ft 1.95
4.25m ave depth; pipe n e 200mm dia m 6.79 ft 2.07
4.50m ave depth; pipe n e 200mm dia m 7.18 ft 2.19
4.75m ave depth; pipe n e 200mm dia m 7.55 ft 2.30
5.00m ave depth; pipe n e 200mm dia m 7.93 ft 2.42
n e 250mm ave depth; pipe over 200 but n e 300mm dia m 0.36 ft 0.11
500mm ave depth; pipe over 200 but n e 300mm dia m 0.36 ft 0.11
750mm ave depth; pipe over 200 but n e 300mm dia m 0.68 ft 0.21
1.00m ave depth; pipe over 200 but n e 300mm dia m 0.96 ft 0.29
1.25m ave depth; pipe over 200 but n e 300mm dia m 1.20 ft 0.37
1.50m ave depth; pipe over 200 but n e 300mm dia m 1.34 ft 0.41
1.70m ave depth; pipe over 200 but n e 300mm dia m 1.98 ft 0.60
2.00m ave depth; pipe over 200 but n e 300mm dia m 2.27 ft 0.69
2.25m ave depth; pipe over 200 but n e 300mm dia m 3.16 ft 0.96
2.50m ave depth; pipe over 200 but n e 300mm dia m 3.51 ft 1.07
2.75m ave depth; pipe over 200 but n e 300mm dia m 4.63 ft 1.41
3.00m ave depth; pipe over 200 but n e 300mm dia m 5.06 ft 1.54
3.25m ave depth; pipe over 200 but n e 300mm dia m 5.47 ft 1.67
3.50m ave depth; pipe over 200 but n e 300mm dia m 5.88 ft 1.79
3.75m ave depth; pipe over 200 but n e 300mm dia m 7.21 ft 2.20
4.00m ave depth; pipe over 200 but n e 300mm dia m 7.70 ft 2.35
4.25m ave depth; pipe over 200 but n e 300mm dia m 8.17 ft 2.49
4.50m ave depth; pipe over 200 but n e 300mm dia m 8.65 ft 2.64
4.75m ave depth; pipe over 200 but n e 300mm dia m 8.37 ft 2.55
5.00m ave depth; pipe over 200 but n e 300mm dia m 9.61 ft 2.93
n e 250mm ave depth; pipe over 300 but n e 400mm dia m 0.16 ft 0.05
500mm ave depth; pipe over 300 but n e 400mm dia m 0.16 ft 0.05
750mm ave depth; pipe over 300 but n e 400mm dia m 0.29 ft 0.09
1.00m ave depth; pipe over 300 but n e 400mm dia m 0.43 ft 0.13
1.25m ave depth; pipe over 300 but n e 400mm dia m 0.51 ft 0.16
1.50m ave depth; pipe over 300 but n e 400mm dia m 0.61 ft 0.18
1.70m ave depth; pipe over 300 but n e 400mm dia m 0.71 ft 0.22
2.00m ave depth; pipe over 300 but n e 400mm dia m 0.81 ft 0.25
2.25m ave depth; pipe over 300 but n e 400mm dia m 1.23 ft 0.37
2.50m ave depth; pipe over 300 but n e 400mm dia m 1.35 ft 0.41
2.75m ave depth; pipe over 300 but n e 400mm dia m 1.50 ft 0.46
3.00m ave depth; pipe over 300 but n e 400mm dia m 1.62 ft 0.49
3.25m ave depth; pipe over 300 but n e 400mm dia m 1.93 ft 0.59
3.50m ave depth; pipe over 300 but n e 400mm dia m 2.09 ft 0.64
3.75m ave depth; pipe over 300 but n e 400mm dia m 2.60 ft 0.79
4.00m ave depth; pipe over 300 but n e 400mm dia m 2.76 ft 0.84
4.25m ave depth; pipe over 300 but n e 400mm dia m 2.95 ft 0.90
4.50m ave depth; pipe over 300 but n e 400mm dia m 3.13 ft 0.95
4.75m ave depth; pipe over 300 but n e 400mm dia m 3.30 ft 1.01
5.00m ave depth; pipe over 300 but n e 400mm dia m 3.48 ft 1.06
By machine
n e 250mm average (ave) depth; pipe n e 200mm dia m 0.12 ft 0.04
500mm ave depth; pipe n e 200mm dia m 0.12 ft 0.04
750mm ave depth; pipe n e 200mm dia m 0.23 ft 0.07
1.00m ave depth; pipe n e 200mm dia m 0.29 ft 0.09
1.25m ave depth; pipe n e 200mm dia m 0.38 ft 0.12
1.50m ave depth; pipe n e 200mm dia m 0.50 ft 0.15
1.70m ave depth; pipe n e 200mm dia m 0.59 ft 0.18
2.00m ave depth; pipe n e 200mm dia m 0.67 ft 0.20
2.25m ave depth; pipe n e 200mm dia m 1.02 ft 0.31
2.50m ave depth; pipe n e 200mm dia m 1.13 ft 0.34
2.75m ave depth; pipe n e 200mm dia m 1.24 ft 0.38
3.00m ave depth; pipe n e 200mm dia m 1.35 ft 0.41
3.25m ave depth; pipe n e 200mm dia m 1.77 ft 0.54
3.50m ave depth; pipe n e 200mm dia m 1.93 ft 0.59
3.75m ave depth; pipe n e 200mm dia m 2.47 ft 0.75
4.00m ave depth; pipe n e 200mm dia m 2.60 ft 0.79
4.25m ave depth; pipe n e 200mm dia m 2.78 ft 0.85
4.50m ave depth; pipe n e 200mm dia m 2.96 ft 0.90
4.75m ave depth; pipe n e 200mm dia m 3.16 ft 0.96
5.00m ave depth; pipe n e 200mm dia m 3.35 ft 1.02Extra over; for excavation by hand for the first 1m m 0.75 ft 0.23
DRAINAGE
Excavate trench; provide temporary support; backfill with selected excavated material; remainder remove to agreed location on site;
Labour Norm Hrs.
Excavate trench; provide temporary support; backfill with selected excavated material; remainder remove to agreed location on site;
Excavate trench; provide temporary support; backfill with selected excavated material; remainder remove to agreed location on site;
Excavate trench; provide temporary support; backfill with selected excavated material; remainder remove to agreed location on site;
Labour Norm Hrs.
New Work
327
n e 250mm ave depth; pipe over 200 but n e 300mm dia m 0.16 ft 0.05
500mm ave depth; pipe over 200 but n e 300mm dia m 0.16 ft 0.05
750mm ave depth; pipe over 200 but n e 300mm dia m 0.29 ft 0.09
1.00m ave depth; pipe over 200 but n e 300mm dia m 0.43 ft 0.13
1.25m ave depth; pipe over 200 but n e 300mm dia m 0.51 ft 0.16
1.50m ave depth; pipe over 200 but n e 300mm dia m 0.50 ft 0.15
1.70m ave depth; pipe over 200 but n e 300mm dia m 0.71 ft 0.22
2.00m ave depth; pipe over 200 but n e 300mm dia m 0.81 ft 0.25
2.25m ave depth; pipe over 200 but n e 300mm dia m 1.02 ft 0.31
2.50m ave depth; pipe over 200 but n e 300mm dia m 1.13 ft 0.34
2.75m ave depth; pipe over 200 but n e 300mm dia m 1.50 ft 0.46
3.00m ave depth; pipe over 200 but n e 300mm dia m 1.62 ft 0.49
3.25m ave depth; pipe over 200 but n e 300mm dia m 1.77 ft 0.54
3.50m ave depth; pipe over 200 but n e 300mm dia m 1.93 ft 0.59
3.75m ave depth; pipe over 200 but n e 300mm dia m 2.60 ft 0.79
4.00m ave depth; pipe over 200 but n e 300mm dia m 2.76 ft 0.84
4.25m ave depth; pipe over 200 but n e 300mm dia m 2.95 ft 0.90
4.50m ave depth; pipe over 200 but n e 300mm dia m 3.13 ft 0.95
4.75m ave depth; pipe over 200 but n e 300mm dia m 3.30 ft 1.01
5.00m ave depth; pipe over 200 but n e 300mm dia m 3.48 ft 1.06
Extra over; for excavation by hand for the first 1m m 0.96 ft 0.29
n e 250mm ave depth; pipe over 300 but n e 400mm dia m 0.36 ft 0.11
500mm ave depth; pipe over 300 but n e 400mm dia m 0.36 ft 0.11
750mm ave depth; pipe over 300 but n e 400mm dia m 0.68 ft 0.21
1.00m ave depth; pipe over 300 but n e 400mm dia m 0.96 ft 0.29
1.25m ave depth; pipe over 300 but n e 400mm dia m 1.20 ft 0.37
1.50m ave depth; pipe over 300 but n e 400mm dia m 1.70 ft 0.52
1.70m ave depth; pipe over 300 but n e 400mm dia m 1.98 ft 0.60
2.00m ave depth; pipe over 300 but n e 400mm dia m 2.27 ft 0.69
2.25m ave depth; pipe over 300 but n e 400mm dia m 3.72 ft 1.14
2.50m ave depth; pipe over 300 but n e 400mm dia m 4.22 ft 1.29
2.75m ave depth; pipe over 300 but n e 400mm dia m 4.63 ft 1.41
3.00m ave depth; pipe over 300 but n e 400mm dia m 5.06 ft 1.54
3.25m ave depth; pipe over 300 but n e 400mm dia m 6.51 ft 1.98
3.50m ave depth; pipe over 300 but n e 400mm dia m 7.00 ft 2.14
3.75m ave depth; pipe over 300 but n e 400mm dia m 7.21 ft 2.20
4.00m ave depth; pipe over 300 but n e 400mm dia m 7.70 ft 2.35
4.25m ave depth; pipe over 300 but n e 400mm dia m 8.17 ft 2.49
4.50m ave depth; pipe over 300 but n e 400mm dia m 8.65 ft 2.64
4.75m ave depth; pipe over 300 but n e 400mm dia m 8.37 ft 2.55
5.00m ave depth; pipe over 300 but n e 400mm dia m 9.61 ft 2.93extra over; excavation by hand for the first 1m m 0.96 ft 0.29
service; single pipe; n e 200mm dia pipe, 250mm ave depth m 0.30 ft 0.09
service; single pipe; n e 200mm dia pipe, 500mm ave depth m 0.30 ft 0.09
service; single pipe; n e 200mm dia pipe, 750mm ave depth m 0.41 ft 0.13
service; single pipe; n e 200mm dia pipe, 1000mm ave depth m 0.47 ft 0.14
service; two pipe cluster; n e 200mm dia pipe, 250mm ave depth m 0.33 ft 0.10
service; two pipe cluster; n e 200mm dia pipe, 500mm ave depth m 0.34 ft 0.10
service; two pipe cluster; n e 200mm dia pipe, 750mm ave depth m 0.44 ft 0.13
service; two pipe cluster; n e 200mm dia pipe, 1000mm ave depth m 0.50 ft 0.15
service; four pipe cluster; n e 200mm dia pipe, 250mm ave depth m 0.63 ft 0.19
service; four pipe cluster; n e 200mm dia pipe, 500mm ave depth m 0.64 ft 0.20
service; four pipe cluster; n e 200mm dia pipe, 750mm ave depth m 0.85 ft 0.26
service; four pipe cluster; n e 200mm dia pipe, 1000mm ave depth m 0.97 ft 0.30
service; eight pipe cluster; n e 200mm dia pipe, 250mm ave depth m 0.63 ft 0.19
service; eight pipe cluster; n e 200mm dia pipe, 500mm ave depth m 0.64 ft 0.20
service; eight pipe cluster; n e 200mm dia pipe, 750mm ave depth m 0.85 ft 0.26
service; eight pipe cluster; n e 200mm dia pipe, 1000mm ave depth m 0.97 ft 0.30
rock m3 1.63 yd3 1.25
concrete m3 1.63 yd3 1.25
reinforced concrete m3 2.86 yd3 2.18
brickwork or blockwork m3 1.23 yd3 0.94
coated macadam or asphalt m3 0.82 yd3 0.62
compacted hardcore m3 0.82 yd3 0.62
100mm thick concrete paving; pipe n e 200mm dia m 0.52 ft 0.16
100mm thick concrete paving; pipe over 200 but n e 300mm dia m 0.74 ft 0.23
100mm thick concrete paving; pipe over 300 but n e 400mm dia m 0.74 ft 0.23
100mm thick reinforced concrete paving; pipe n e 200mm dia m 0.59 ft 0.18
100mm thick reinforced concrete paving; pipe over 200 but n e 300mm dia
m 0.87 ft 0.27
100mm thick reinforced concrete paving; pipe over 300 but n e 400mm dia
m 0.87 ft 0.27
200mm thick reinforced concrete road; pipe n e 200mm dia m 1.34 ft 0.41
200mm thick reinforced concrete road; pipe over 200 but n e 300mm dia m 1.67 ft 0.51
200mm thick reinforced concrete road; pipe over 300 but n e 400mm dia m 1.67 ft 0.51
100mm thick brick or block paving, pipe n e 200mm dia m 1.21 ft 0.37
100 thick brick or block paving, pipe over 200 but n e 300mm dia m 1.21 ft 0.37
100mm thick brick or block paving, pipe over 300 but n e 400mm dia m 1.21 ft 0.37
100mm thick paving; pipe n e 200mm dia m 1.21 ft 0.37
100mm thick paving; pipe over 200 but n e 300mm dia m 1.21 ft 0.37
100mm thick paving; pipe over 300 but n e 400mm dia m 1.21 ft 0.37
Excavate trench; provide temporary support; backfill with selected excavated material; remainder remove to agreed location on site
Extra over excavation for breaking out; irrespective of depth of excavation; paving and hardcore bed under; reinstatement to match existing
Extra over excavation for breaking out; irrespective of depth of excavation; flexible road surfacing and bed under
Extra over excavation for breaking out; irrespective of depth of excavation; paving and bed under; including setting aside bricks or blocks for use in reinstatement
Excavate trench; provide temporary support; backfill with selected excavated material; remainder remove to agreed location on site;
Extra over excavation for breaking out; irrespective of depth of excavation
Excavate trench; provide temporary support; backfill with selected excavated material; remainder remove to agreed location on site;
328
existing service cable or group of cabling; pipe n e 200mm dia. m 0.22 ft 0.07
existing service pipe n e 200mm dia; pipe n e 200mm dia m 0.22 ft 0.07
existing service pipe n e 300mm dia; pipe n e 200mm dia m 0.22 ft 0.07
existing service pipe n e 400mm dia; pipe n e 200mm dia. m 0.33 ft 0.10
existing service pipe; group; n e 1m wide; pipe n e 200mm dia m 0.33 ft 0.10
existing service cable or group of cabling; pipe over 200 but n e 300mm dia. m 0.22 ft 0.07
existing service pipe n e 200mm dia; pipe over 200 but n e 300mm dia m 0.22 ft 0.07
existing service pipe n e 300mm dia; pipe over 200 but n e 300mm dia m 0.22 ft 0.07
existing service pipe n e 400mm dia; pipe over 200 but n e 300mm dia. m 0.33 ft 0.10
existing service pipe; group; n e 1m wide; pipe over 200 but n e 300mm dia m 0.33 ft 0.10
existing service cable or group of cabling; pipe over 300 but n e 400mm dia. m 0.22 ft 0.07
existing service pipe n e 200mm dia; pipe over 300 but n e 400mm dia m 0.22 ft 0.07
existing service pipe n e 300mm dia; pipe over 300 but n e 400mm dia m 0.22 ft 0.07
existing service pipe n e 400mm dia; pipe over 300 but n e 400mm dia. m 0.33 ft 0.10
existing service pipe; group; n e 1m wide; pipe over 300 but n e 400mm dia m 0.33 ft 0.10
existing service cable or group of cabling; pipe n e 200mm dia nr 0.88 Nr 0.88
existing service pipe n e 200mm dia; pipe n e 200mm dia; nr 0.88 Nr 0.88
existing service pipe n e 300mm dia; pipe n e 200mm dia nr 0.88 Nr 0.88
existing service pipe n e 400mm dia; pipe n e 200mm dia nr 1.11 Nr 1.11
existing service pipe; group; n e 1m wide; pipe n e 200mm dia nr 1.11 Nr 1.11
existing service cable or group of cabling; pipe over 200 but n e 300mm dia nr 0.88 Nr 0.88
existing service pipe n e 200mm dia; pipe over 200 but n e 300mm dia; nr 0.88 Nr 0.88
existing service pipe n e 300mm dia; pipe over 200 but n e 300mm dia nr 0.88 Nr 0.88
existing service pipe n e 400mm dia; pipe over 200 but n e 300mm dia nr 1.11 Nr 1.11
existing service pipe; group; n e 1m wide; pipe over 200 but n e 300mm dia nr 1.11 Nr 1.11
existing service cable or group of cabling; pipe over 300 but n e 400mm dia nr 0.88 Nr 0.88
existing service pipe n e 200mm dia; pipe over 300 but n e 400mm dia; nr 0.88 Nr 0.88
existing service pipe n e 300mm dia; pipe over 300 but n e 400mm dia nr 0.88 Nr 0.88
existing service pipe n e 400mm dia; pipe over 300 but n e 400mm dia nr 1.11 Nr 1.11
existing service pipe; group; n e 1m wide; pipe over 300 but n e 400mm dia nr 1.11 Nr 1.11
pipe n e 200mm dia m 0.69 ft 0.21
pipe over 200 but n e 300mm dia m 0.69 ft 0.21
pipe over 300 but n e 400mm dia m 0.69 ft 0.21
Filling
400 x 250mm thick m 0.10 ft 0.03
450 x 300mm thick m 0.13 ft 0.04
500 x 350mm thick m 0.14 ft 0.04
600 x 450mm thick m 0.17 ft 0.05
750 x 600mm thick m 0.24 ft 0.07
400 x 400mm thick m 0.24 ft 0.07
450 x 450mm thick m 0.26 ft 0.08
500 x 500mm thick m 0.40 ft 0.12
600 x 600mm thick m 0.38 ft 0.12
750 x 750mm thick m 0.49 ft 0.15
400 x 400mm thick m 0.34 ft 0.10
450 x 450mm thick m 0.39 ft 0.12
500 x 500mm thick m 0.56 ft 0.17
600 x 600mm thick m 0.71 ft 0.22
750 x 750mm thick m 0.88 ft 0.27
400 x 400mm thick m 0.33 ft 0.10
450 x 450mm thick m 0.30 ft 0.09
500 x 500mm thick m 0.38 ft 0.12
600 x 600mm thick m 0.48 ft 0.15
750 x 750mm thick m 0.76 ft 0.23
400 x 250mm thick m 0.33 ft 0.10
450 x 300mm thick m 0.43 ft 0.13
500 x 350mm thick m 0.54 ft 0.16
600 x 450mm thick m 0.70 ft 0.21
750 x 600mm thick m 1.06 ft 0.32
400 x 400mm thick m 0.21 ft 0.06
450 x 450mm thick m 0.23 ft 0.07
500 x 500mm thick m 0.26 ft 0.08
600 x 600mm thick m 0.31 ft 0.09
750 x 750mm thick m 0.40 ft 0.12
400 x 400mm thick m 0.58 ft 0.18
450 x 450mm thick m 0.75 ft 0.23
500 x 500mm thick m 0.93 ft 0.28
600 x 600mm thick m 1.24 ft 0.38
750 x 750mm thick m 1.66 ft 0.51
Pipework
trench; pipe 150mm dia m 3.12 ft 0.95
trench; pipe 200mm dia m 3.61 ft 1.10
trench; pipe 250mm dia m 4.23 ft 1.29
trench; pipe 300mm dia m 5.26 ft 1.60
trench; pipe 350mm dia m 5.99 ft 1.83
trench; pipe 400mm dia m 6.44 ft 1.96
duct; pipe 150mm dia m 3.06 ft 0.93
duct; pipe 200mm dia m 3.38 ft 1.03
duct; pipe 250mm dia m 3.95 ft 1.21
duct; pipe 300mm dia m 4.57 ft 1.40
duct; pipe 350mm dia m 4.92 ft 1.50
duct; pipe 400mm dia m 5.26 ft 1.60
Extra over excavation irrespective of depth; working around existing; crossing excavation
Lay; bed and haunch; plain insitu concrete
Lay G R E pipework; including testing
Lay G R E pipework; including testing
Extra over excavation irrespective of depth; working next existing
Lay; bed and haunch; granular material
Lay; bed and surround; plain insitu concrete
Lay; bed and surround; granular material
Protect with road plate to facilitate the passage of vehicular traffic over open trench excavation; irrespective depth of excavation (2 weeks hire period)
Lay; vertical casing; plain insitu concrete
Lay; vertical casing; granular material
Lay; bed and surround; sand
329
blank cap; pipe 150mm dia nr 1.89 Nr 1.89
blank cap; pipe 200mm dia nr 2.13 Nr 2.13
blank cap; pipe 250mm dia nr 2.87 Nr 2.87
blank cap; pipe 300mm dia nr 3.38 Nr 3.38
blank cap; pipe 350mm dia nr 4.06 Nr 4.06
blank cap; pipe 400mm dia nr 4.90 Nr 4.90
reducer 200 to 150mm nr 1.52 Nr 1.52
reducer 250 to 150mm nr 2.03 Nr 2.03
reducer 250 to 200mm nr 2.37 Nr 2.37
reducer 300 to 200mm nr 2.37 Nr 2.37
reducer 300 to 250mm nr 2.67 Nr 2.67
reducer 350 to 250mm nr 2.67 Nr 2.67
reducer 350 to 300mm nr 3.08 Nr 3.08
reducer 400 to 300mm nr 3.08 Nr 3.08
reducer 400 to 350mm nr 3.48 Nr 3.48
bend; pipe 150mm dia nr 1.08 Nr 1.08
bend; pipe 200mm dia nr 1.35 Nr 1.35
bend; pipe 250mm dia nr 1.52 Nr 1.52
bend; pipe 300mm dia nr 1.69 Nr 1.69
bend; pipe 350mm dia nr 1.83 Nr 1.83
bend; pipe 400mm dia nr 2.10 Nr 2.10
branch; pipe 150mm dia nr 0.79 Nr 0.79
branch; pipe 200mm dia nr 1.58 Nr 1.58
branch; pipe 250mm dia nr 1.88 Nr 1.88
branch; pipe 300mm dia nr 2.73 Nr 2.73
branch; pipe 350mm dia nr 3.24 Nr 3.24
branch; pipe 400mm dia nr 3.75 Nr 3.75
Y-branch; pipe 150mm dia nr 2.87 Nr 2.87
Y-branch; pipe 200mm dia nr 3.25 Nr 3.25
Y-branch; pipe 250mm dia nr 3.72 Nr 3.72
Y-branch; pipe 300mm dia nr 4.39 Nr 4.39
Y-branch; pipe 350mm dia nr 5.27 Nr 5.27
Y-branch; pipe 400mm dia nr 6.76 Nr 6.76
puddle flange; pipe 150mm dia nr 1.18 Nr 1.18
puddle flange; pipe 200mm dia nr 1.42 Nr 1.42
puddle flange; pipe 250mm dia nr 1.86 Nr 1.86
puddle flange; pipe 300mm dia nr 2.43 Nr 2.43
puddle flange; pipe 350mm dia nr 3.01 Nr 3.01
puddle flange; pipe 400mm dia nr 3.55 Nr 3.55
trench; 100mm nominal dia m 0.05 ft 0.01
trench; 150mm nominal dia m 0.27 ft 0.08
duct; 100mm nominal dia m 0.18 ft 0.06
duct; 150mm nominal dia m 0.22 ft 0.07
blank cap; pipe 100mm dia nr 0.23 Nr 0.23
blank cap; pipe 150mm dia nr 0.36 Nr 0.36
reducer; pipe 150 to 100mm dia nr 0.22 Nr 0.22
bend; pipe 100mm dia nr 0.18 Nr 0.18
bend; pipe 150mm dia nr 0.27 Nr 0.27
short radius bend; pipe 100mm dia nr 0.18 Nr 0.18
short radius bend; pipe 150mm dia nr 0.22 Nr 0.22
long radius bend; pipe 100mm thick nr 0.18 Nr 0.18
long radius bend; pipe 150mm thick nr 0.22 Nr 0.22
branch; pipe 100mm dia nr 0.82 Nr 0.82
branch; pipe 150mm dia nr 0.82 Nr 0.82
trench; pipe 225mm dia m 0.34 ft 0.10
trench; pipe 300mm dia m 0.80 ft 0.24
trench; pipe 375mm dia m 0.88 ft 0.27
duct; pipe 225mm dia m 0.56 ft 0.17
duct; pipe 300mm dia m 0.86 ft 0.26
duct; pipe 375mm dia m 1.06 ft 0.32
blank cap; pipe 225mm dia nr 0.02 Nr 0.02
blank cap; pipe 300mm dia nr 0.59 Nr 0.59
blank cap; pipe 375mm dia nr 1.42 Nr 1.42
reducer pipe 300 to 225mm dia nr 2.04 Nr 2.04
reducer pipe 375 to 225mm dia nr 2.34 Nr 2.34
reducer pipe 375 to 300mm dia nr 2.55 Nr 2.55
bend; pipe 225mm dia nr 1.87 Nr 1.87
bend; pipe 300mm dia nr 2.95 Nr 2.95
bend; pipe 375mm dia nr 3.74 Nr 3.74
long radius bend; pipe 225mm dia nr 1.87 Nr 1.87
long radius bend; pipe 300mm dia nr 2.95 Nr 2.95
long radius bend; pipe 375mm dia nr 3.74 Nr 3.74
branch; pipe 225mm dia nr 2.04 Nr 2.04
branch; pipe 300mm dia nr 2.34 Nr 2.34
branch; pipe 375mm dia nr 2.55 Nr 2.55
Y-branch; pipe 225mm dia nr 1.38 Nr 1.38
Y-branch; pipe 300mm dia nr 1.45 Nr 1.45
Y-branch; pipe 375mm dia nr 1.49 Nr 1.49
double parallel branch; pipe 225mm dia nr 0.00 Nr 0.00
double parallel branch; pipe 300mm dia nr 0.00 Nr 0.00
double parallel branch; pipe 375mm dia nr 0.00 Nr 0.00
diminishing piece; pipe 225mm dia nr 1.62 Nr 1.62
diminishing piece; pipe 300mm dia nr 2.29 Nr 2.29
diminishing piece; pipe 375mm dia nr 3.11 Nr 3.11
trench; pipe 100mm dia m 0.12 ft 0.04
trench; pipe 150mm dia m 0.20 ft 0.06
trench; pipe 225mm dia m -0.28 ft -0.08
trench; pipe 300mm dia m -0.41 ft -0.13
duct; pipe 100mm dia m 0.16 ft 0.05
duct; pipe 150mm dia m 0.27 ft 0.08
duct; pipe 225mm dia m 0.52 ft 0.16
duct; pipe 300mm dia m 0.77 ft 0.23
Extra over concrete land drainage porous pipe; fixing
Lay precast clay pipework to BS 65; push fit flexible jointing
Extra over; precast concrete pipe; ogee joint; fixing
Lay concrete land drainage porous pipe; butt jointed
Extra over G R E pipework; fixing;
Lay precast concrete pipe; ogee jointing, including testing
Lay precast concrete pipe; ogee jointing, including testing
330
blank cap; pipe 100mm dia nr 0.07 Nr 0.07
blank cap; pipe 150mm dia nr 0.15 Nr 0.15
blank cap; pipe 225mm dia nr 1.61 Nr 1.61
blank cap; pipe 300mm dia nr 2.54 Nr 2.54
reducer; pipe 150 to 100mm dia nr 0.27 Nr 0.27
reducer; pipe 225 to 100mm dia nr 0.85 Nr 0.85
reducer; pipe 225 to 150mm dia nr 0.65 Nr 0.65
reducer; pipe 300 to 100mm dia nr 1.87 Nr 1.87
reducer; pipe 300 to 150mm dia nr 1.87 Nr 1.87
reducer; pipe 300 to 225mm dia nr 1.87 Nr 1.87
bend; pipe 100mm dia nr 0.13 Nr 0.13
bend; pipe 150mm dia nr 0.24 Nr 0.24
bend; pipe 225mm dia nr 0.77 Nr 0.77
bend; pipe 300mm dia nr 1.36 Nr 1.36
short radius bend; pipe 100mm dia nr 0.15 Nr 0.15
short radius bend; pipe 150mm dia nr 0.29 Nr 0.29
short radius bend; pipe 225mm dia nr 0.77 Nr 0.77
short radius bend; pipe 300mm dia nr 1.36 Nr 1.36
long radius bend; pipe 100mm dia nr 0.15 Nr 0.15
long radius bend; pipe 150mm dia nr 0.29 Nr 0.29
long radius bend; pipe 225mm dia nr 0.77 Nr 0.77
long radius bend; pipe 300mm dia nr 1.36 Nr 1.36
branch; pipe 100mm dia nr 0.19 Nr 0.19
branch; pipe 150mm dia nr 0.31 Nr 0.31
branch; pipe 225mm dia nr 1.10 Nr 1.10
branch; pipe 300mm dia nr 1.60 Nr 1.60
trench; pipe 100mm dia m 0.02 ft 0.01
trench; pipe 150mm dia m 0.29 ft 0.09
bend; pipe 100mm dia nr 0.02 Nr 0.02
bend; pipe 150mm dia nr 0.33 Nr 0.33
short radius bend; pipe 100mm dia nr 0.02 Nr 0.02
short radius bend; pipe 150mm dia nr 0.04 Nr 0.04
long radius bend; pipe 100mm dia nr 0.19 Nr 0.19
long radius bend; pipe 150mm dia nr 0.33 Nr 0.33
branch; pipe 100mm dia nr 0.33 Nr 0.33
branch; pipe 150mm dia nr 0.61 Nr 0.61
Y-branch; pipe 100mm dia nr 0.33 Nr 0.33
Y-branch; pipe 150mm dia nr 0.61 Nr 0.61
double parallel branch; pipe 100mm dia nr 0.33 Nr 0.33
double parallel branch; pipe 150mm dia nr 0.61 Nr 0.61
diminishing piece; pipe 100mm dia nr 0.40 Nr 0.40
diminishing piece; pipe 150mm dia nr 0.73 Nr 0.73
trench; pipe 100mm dia m 0.30 ft 0.09
trench; pipe 150mm dia m 0.46 ft 0.14
bend; pipe 100mm dia nr 0.11 Nr 0.11
bend; pipe 150mm dia nr 0.19 Nr 0.19
long radius bend; pipe 100mm dia nr 0.15 Nr 0.15
long radius bend; pipe 150mm dia nr 0.33 Nr 0.33
short radius bend; pipe 100mm dia nr 0.24 Nr 0.24
short radius bend; pipe 150mm dia nr 0.34 Nr 0.34
branch; pipe 100mm dia nr 0.32 Nr 0.32
branch; pipe 150mm dia nr 0.58 Nr 0.58
Y-branch; pipe 100mm dia nr 0.32 Nr 0.32
Y-branch; pipe 150mm dia nr 0.58 Nr 0.58
double parallel branch; pipe 100mm dia nr 0.32 Nr 0.32
double parallel branch; pipe 150mm dia nr 0.58 Nr 0.58
diminishing piece; pipe 100mm dia nr 0.32 Nr 0.32
diminishing piece; pipe 150mm dia nr 0.58 Nr 0.58
service; single pipe; n e 200mm dia pipe, m 0.04 ft 0.01
service; two pipe cluster; n e 200mm dia pipe, m 0.04 ft 0.01
service; four pipe cluster; n e 200mm dia pipe, m 0.03 ft 0.01
service; eight pipe cluster; n e 200mm dia pipe, m 0.02 ft 0.01
level or to falls; internal 100mm dia m 0.46 ft 0.14
level or to falls; internal 150mm dia m 0.65 ft 0.20
Extra for 100mm dia trapped outlet nr 1.39 Nr 1.39
Extra for end cap nr 0.09 Nr 0.09Lay concrete fitting; plain insitu concrete bed and surround; including all necessary additional excavation; connect to drain
road gully 450 diameter x 900mm deep to BS 556; 150mm outlet; rodding eye and stopper
nr 2.59 Nr 2.59
gully 100mm dia outlet; 150 x 150mm cast iron grating nr 3.85 Nr 3.85
gully 150mm dia outlet; 225 x 225mm cast iron grating nr 2.76 Nr 2.76road gully 300 diameter x 600mm deep; 150mm dia outlet; inspection eye; 225 x 225mm cast iron grating
nr 3.45 Nr 3.45
Lay cast iron fitting; bedding in cement mortar road gully grating; heavy duty; nr 2.15 Nr 2.15
grating; 300mm wide m 0.92 ft 0.28
extra for forming angle nr 2.71 Nr 2.71
extra for cut and fitted end nr 0.58 Nr 0.58
grating; 375mm wide m 2.39 ft 0.73
extra for forming angle nr 4.98 Nr 4.98
extra for cut and fitted end nr 0.35 Nr 0.35
grating; 450mm wide m 0.00 ft 0.00
extra for forming angle nr 0.00 Nr 0.00
extra for cut and fitted end nr 0.00 Nr 0.00
hot applied; pipe 100mm dia m 0.61 ft 0.19
hot applied; pipe 150mm dia m 0.73 ft 0.22
hot applied; pipe 200mm dia m 0.89 ft 0.27
hot applied; pipe 300mm dia m 1.16 ft 0.35
hot applied; pipe 400mm dia m 1.40 ft 0.43
hot applied; pipe 450mm dia m 1.56 ft 0.48
hot applied; pipe 100mm dia m 1.20 ft 0.37
hot applied; pipe 150mm dia m 1.38 ft 0.42
hot applied; pipe 200mm dia m 1.92 ft 0.59
hot applied; pipe 300mm dia m 2.72 ft 0.83
hot applied; pipe 400mm dia m 3.47 ft 1.06
hot applied; pipe 450mm dia m 4.16 ft 1.27
Extra over; precast clay pipework; fixing
Extra over; clay ductwork; fixing
Extra over; uPVC ductwork; fixing
Lay uPVC service pipework; (including draw wire)
Lay galvanised mild steel channel grating; place in position
Apply; double coated wrapped system; welded joint; in trench; testing
Apply; double coated wrapped system; take delivery of pipe material, wrap, (hand to others for installation); testing
Lay clay ductwork; jointed
Lay uPvc ductwork; jointed; split duct around existing cable
Lay glazed stoneware fitting; plain insitu concrete bed and surround; including all necessary additional excavation; connect to drain
Lay interconnecting precast concrete drainage channel; galvanised steel grating; insitu concrete bedding and haunching; jointed and pointed in cement sand mortar
331
pipe 100mm dia m 0.22 ft 0.07
pipe 150mm dia m 0.25 ft 0.08
pipe 200mm dia m 0.29 ft 0.09
pipe 300mm dia m 0.34 ft 0.11
pipe 400mm dia m 0.37 ft 0.11
pipe 450mm dia m 0.46 ft 0.14
cold applied; pipe 100mm dia m 1.20 ft 0.37
cold applied; pipe 150mm dia m 1.38 ft 0.42
cold applied; pipe 200mm dia m 1.92 ft 0.59
cold applied; pipe 300mm dia m 2.72 ft 0.83
cold applied; pipe 400mm dia m 3.47 ft 1.06
cold applied; pipe 450mm dia m 4.16 ft 1.27
benching; ave 150mm thick m2 0.85 ft2 0.08
benching; ave 225mm thick m2 1.10 ft2 0.10
benching; ave 300mm thick m2 1.38 ft2 0.13
wall; 110mm thick m2 1.45 ft2 0.13
wall; 225mm thick m2 3.15 ft2 0.29
brick on edge kerb; 110 x 100mm wide m 0.36 ft 0.11
brick on edge kerb; 110 x 225mm wide m 0.43 ft 0.13
brick on edge kerb; 225 x 225mm wide m 0.76 ft 0.23
pipe 100mm nominal dia; half brick thick nr 0.24 Nr 0.24
pipe 150mm nominal dia; half brick thick nr 0.27 Nr 0.27
pipe 225mm nominal dia; half brick thick nr 0.29 Nr 0.29
pipe 300mm nominal dia; half brick thick nr 0.19 Nr 0.19
pipe 400mm nominal dia; half brick thick nr 0.28 Nr 0.28
pipe 100mm nominal dia; one brick thick nr 0.22 Nr 0.22
pipe 150mm nominal dia; one brick thick nr 0.27 Nr 0.27
pipe 225mm nominal dia; one brick thick nr 0.30 Nr 0.30
pipe 300mm nominal dia; one brick thick nr 0.34 Nr 0.34
pipe 400mm nominal dia; one brick thick nr 0.50 Nr 0.50
pipe 100mm nominal dia; one and a half brick thick nr 0.34 Nr 0.34
pipe 150mm nominal dia; one and a half brick thick nr 0.40 Nr 0.40
pipe 225mm nominal dia; one and a half brick thick nr 0.46 Nr 0.46
pipe 300mm nominal dia; one and a half brick thick nr 0.51 Nr 0.51
pipe 400mm nominal dia; one and a half brick thick nr 0.75 Nr 0.75
pipe 100mm nominal dia; half brick thick nr 0.43 Nr 0.43
pipe 150mm nominal dia; half brick thick nr 0.45 Nr 0.45
pipe 225mm nominal dia; half brick thick nr 0.46 Nr 0.46
pipe 300mm nominal dia; half brick thick nr 0.47 Nr 0.47
pipe 400mm nominal dia; half brick thick nr 0.56 Nr 0.56
pipe 100mm nominal dia; one brick thick nr 0.85 Nr 0.85
pipe 150mm nominal dia; one brick thick nr 0.89 Nr 0.89
pipe 225mm nominal dia; one brick thick nr 0.58 Nr 0.58
pipe 300mm nominal dia; one brick thick nr 0.62 Nr 0.62
pipe 400mm nominal dia; one brick thick nr 0.78 Nr 0.78
pipe 100mm nominal dia; one and a half brick thick nr 0.62 Nr 0.62
pipe 150mm nominal dia; one and a half brick thick nr 0.69 Nr 0.69
pipe 225mm nominal dia; one and a half brick thick nr 0.74 Nr 0.74
pipe 300mm nominal dia; one and a half brick thick nr 0.79 Nr 0.79
pipe 400mm nominal dia; one and a half brick thick nr 1.03 Nr 1.03
brickwork wall; over 300mm wide m2 0.41 ft2 0.04
brickwork wall; n e 300mm wide m 0.24 ft 0.07
extra for rounded internal angle and intersection 25mm radius m 0.06 ft 0.02
half round channel; 100mm nominal dia; effective length n e 900mm nr 0.16 Nr 0.16
half round channel; 150mm nominal dia; effective length n e 900mm nr 0.19 Nr 0.19
half round channel; 225mm nominal dia; effective length n e 900mm nr 0.37 Nr 0.37
half round channel; 300mm nominal dia; effective length n e 900mm nr 0.28 Nr 0.28three quarter section channel; 100mm nominal dia; effective length n e 900mm
nr 0.20 Nr 0.20
three quarter section channel; 150mm nominal dia; effective length n e 900mm
nr 0.28 Nr 0.28
three quarter section channel; 225mm nominal dia; effective length n e 900mm
nr 0.60 Nr 0.60
three quarter section channel; 300mm nominal dia; effective length n e 900mm
nr 0.99 Nr 0.99
half section branch bend; 100mm nominal dia; nr 0.26 Nr 0.26
half section branch bend; 150mm nominal dia; nr 0.06 Nr 0.06
half section branch bend; 225mm nominal dia; nr 1.09 Nr 1.09
half section branch bend; 300mm nominal dia; nr 2.07 Nr 2.07
three quarter section branch bend; 100mm nominal dia; nr 0.27 Nr 0.27
three quarter section branch bend; 150mm nominal dia; nr 0.44 Nr 0.44
three quarter section branch bend; 225mm nominal dia; nr 1.31 Nr 1.31
three quarter section branch bend; 300mm nominal dia; nr 2.56 Nr 2.56
medium duty single seal; 550mm dia; nr 1.54 Nr 1.54
heavy duty single seal; 550mm dia; nr 1.84 Nr 1.84
double triangular(Grade A table 1.130); 500mm dia opening; nr 1.84 Nr 1.84
medium duty single seal; 600 x 450mm clear opening; nr 1.24 Nr 1.24
medium duty single seal; 600 x 600mm clear opening; nr 1.52 Nr 1.52
Build in; to brickwork step iron nr 0.11 Nr 0.11
pipe 100mm nominal dia nr 2.58 Nr 2.58
pipe 150mm nominal dia nr 3.16 Nr 3.16
pipe 225mm nominal dia nr 3.98 Nr 3.98
pipe 300mm nominal dia nr 4.56 Nr 4.56
pipe 400mm nominal dia nr 5.38 Nr 5.38
Break into existing manhole wall and build in end of pipe; including all making good
Lay engineering brickwork; Class B to BS3921 Table 6; bedded, jointed and pointed cement mortar (1:4)
Lay; plain insitu concrete; grade C25 fine concrete; to slopes with rounded edges to channels; trowelling
Build in; end of pipe
Lay cast iron access cover and frame; filling seal with grease; casting into concrete
Apply; double coat wrapped system; welded joint; in trench; testing
Build in; end of pipe including building in puddle flange (supplied by others)
Apply rendering; 12mm thick cement and sand (1:3); internally; trowel finish
Lay vitrified clay channel; bedded and jointed in cement mortar
Apply wrapping tape; in trench
332
pipework; irrespective of material; n e 200mm internal dia m 0.05 ft 0.02
pipework; irrespective of material; over 200 but n e 300mm dia m 0.05 ft 0.02
pipework: irrespective of material; over 300 but n e 400mm dia m 0.06 ft 0.02pipework: irrespective of material; over 400mm dia m 0.07 ft 0.02550 diameter; medium duty single seal nr 0.08 Nr 0.08550 diameter; heavy duty single seal nr 0.08 Nr 0.08500 diameter opening; double triangular(Grade A table 1.130) nr 0.08 Nr 0.08600 x 450 clear opening; medium duty single seal nr 0.08 Nr 0.08600 x 600 clear opening; medium duty single seal nr 0.08 Nr 0.08
manhole internal volume n e 1.00m3 nr 0.50 Nr 0.50
manhole internal volume over 1.00m3 but ne 2.50m3 nr 0.55 Nr 0.55
manhole internal volume over 2.50m3 but n e 4.00m3 nr 0.65 Nr 0.65
manhole internal volume over 4.00m3 but n e 5.50m3 nr 0.75 Nr 0.75
manhole internal volume over 5.50m3 but n e 7.00m3 nr 1.00 Nr 1.00
manhole internal volume over 7.00m3 but n e 8.50m3 nr 1.25 Nr 1.25
manhole internal volume over 8.50m3 but n e 10.00m3 nr 1.50 Nr 1.50
manhole internal volume over 10.00m3 nr 1.75 Nr 1.75100mm dia outlet; 150 x 150mm cast iron grating nr 0.36 Nr 0.36
150mm dia outlet; 225 x 225mm cast iron grating nr 0.36 Nr 0.36
300mm dia x 600 deep; 150mm dia outlet; inspection eye; 225 x 225mm cast iron grating
nr 0.36 Nr 0.36
450mm dia x 900 deep to BS 556; 150mm dia outlet; rodding eye and stopper
nr 0.36 Nr 0.36
pipework; irrespective of material; 100mm internal dia m 0.06 ft 0.02
Clean
Remove grating; clean out existing rainwater gulley with flushing water including using drain rods or other approved system to remove blockages, and reinstate grating on completion.
Remove grating; clean out road gulley with flushing water including using drain rods or other approved system to remove blockage; and reinstate grating on completion
Clean out existing precast concrete drainage channel with flushing water including using drain rods or other approved system to remove blockage
Clean out existing drain run with flushing water using drain rods or other approved system to remove blockage; locate and remove from 'rodding eye' point to access and reinstate on completionClean surface of surface debris; lift and relay with approved bedding material, cast iron cover and frame
Access lift existing manhole cover; clean out existing brick or concrete manhole chamber internally with flushing water including using drain rods or other approved system to remove blockage and replace access cover on completion
333
n e 200mm dia pipe, 250mm average depth nr 0.30 Nr 0.30
n e 200mm dia pipe, 500mm average depth nr 0.30 Nr 0.30
n e 200mm dia pipe, 750mm average depth nr 0.58 Nr 0.58
n e 200mm dia pipe, 1000mm average depth nr 0.78 Nr 0.78
n e 200mm dia pipe, 1250mm average depth nr 0.94 Nr 0.94
n e 200mm dia pipe, 1500mm average depth nr 1.37 Nr 1.37
n e 200mm dia pipe, 1750mm average depth nr 1.59 Nr 1.59
n e 200mm dia pipe, 2000mm average depth nr 1.82 Nr 1.82
n e 200mm dia pipe, 2250mm average depth nr 3.19 Nr 3.19
n e 200mm dia pipe, 2500mm average depth nr 3.54 Nr 3.54
n e 200mm dia pipe, 2750mm average depth nr 3.89 Nr 3.89
n e 200mm dia pipe, 3000mm average depth nr 4.25 Nr 4.25
n e 200mm dia pipe, 3250mm average depth nr 5.50 Nr 5.50
n e 200mm dia pipe, 3500mm average depth nr 5.91 Nr 5.91
n e 200mm dia pipe, 3750mm average depth nr 6.04 Nr 6.04
n e 200mm dia pipe, 4000mm average depth nr 6.43 Nr 6.43
n e 200mm dia pipe, 4250mm average depth nr 6.82 Nr 6.82
n e 200mm dia pipe, 4500mm average depth nr 7.21 Nr 7.21
n e 200mm dia pipe, 4750mm average depth nr 7.58 Nr 7.58
n e 200mm dia pipe, 5000mm average depth nr 7.96 Nr 7.96
over 200 but n e 300mm dia pipe, 250mm average depth nr 0.39 Nr 0.39
over 200 but n e 300mm dia pipe, 500mm average depth nr 0.39 Nr 0.39
over 200 but n e 300mm dia pipe, 750mm average depth nr 0.71 Nr 0.71
over 200 but n e 300mm dia pipe, 1000mm average depth nr 0.99 Nr 0.99
over 200 but n e 300mm dia pipe, 1250mm average depth nr 1.23 Nr 1.23
over 200 but n e 300mm dia pipe, 1500mm average depth nr 1.37 Nr 1.37
over 200 but n e 300mm dia pipe, 1750mm average depth nr 2.01 Nr 2.01
over 200 but n e 300mm dia pipe, 2000mm average depth nr 2.30 Nr 2.30
over 200 but n e 300mm dia pipe, 2250mm average depth nr 3.19 Nr 3.19
over 200 but n e 300mm dia pipe, 2500mm average depth nr 3.54 Nr 3.54
over 200 but n e 300mm dia pipe, 2750mm average depth nr 4.66 Nr 4.66
over 200 but n e 300mm dia pipe, 3000mm average depth nr 5.09 Nr 5.09
over 200 but n e 300mm dia pipe, 3250mm average depth nr 5.50 Nr 5.50
over 200 but n e 300mm dia pipe, 3500mm average depth nr 5.91 Nr 5.91
over 200 but n e 300mm dia pipe, 3750mm average depth nr 7.24 Nr 7.24
over 200 but n e 300mm dia pipe 4000mm average depth nr 7.73 Nr 7.73
over 200 but n e 300mm dia pipe, 4250mm average depth nr 8.20 Nr 8.20
over 200 but n e 300mm dia pipe, 4500mm average depth nr 8.68 Nr 8.68
over 200 but n e 300mm dia pipe, 4750mm average depth nr 9.00 Nr 9.00
over 200 but n e 300mm dia pipe, 5000mm average depth nr 9.64 Nr 9.64
over 300 but n e 400mm dia pipe, 250mm average depth nr 0.39 Nr 0.39
over 300 but n e 400mm dia pipe, 500mm average depth nr 0.39 Nr 0.39
over 300 but n e 400mm dia pipe, 750mm average depth nr 0.71 Nr 0.71
over 300 but n e 400mm dia pipe, 1000mm average depth nr 0.99 Nr 0.99
over 300 but n e 400mm dia pipe, 1250mm average depth nr 1.23 Nr 1.23
over 300 but n e 400mm dia pipe, 1500mm average depth nr 1.37 Nr 1.37
over 300 but n e 400mm dia pipe, 1750mm average depth nr 2.01 Nr 2.01
over 300 but n e 400mm dia pipe, 2000mm average depth nr 2.30 Nr 2.30
over 300 but n e 400mm dia pipe, 2250mm average depth nr 3.19 Nr 3.19
over 300 but n e 400mm dia pipe, 2500mm average depth nr 3.54 Nr 3.54
over 300 but n e 400mm dia pipe, 2750mm average depth nr 4.66 Nr 4.66
over 300 but n e 400mm dia pipe, 3000mm average depth nr 5.09 Nr 5.09
over 300 but n e 400mm dia pipe, 3250mm average depth nr 5.50 Nr 5.50
over 300 but n e 400mm dia pipe, 3500mm average depth nr 5.91 Nr 5.91
over 300 but n e 400mm dia pipe, 3750mm average depth nr 7.24 Nr 7.24
over 300 but n e 400mm dia pipe 4000mm average depth nr 7.73 Nr 7.73
over 300 but n e 400mm dia pipe, 4250mm average depth nr 8.20 Nr 8.20
over 300 but n e 400mm dia pipe, 4500mm average depth nr 8.68 Nr 8.68
over 300 but n e 400mm dia pipe, 4750mm average depth nr 9.00 Nr 9.00
over 300 but n e 400mm dia pipe, 5000mm average depth nr 9.64 Nr 9.64
n e 200mm diameter nr 0.28 Nr 0.28
over 200 but n e 300mm diameter nr 0.34 Nr 0.34
over 300 but n e 400mm diameter nr 0.39 Nr 0.39
n e 200mm diameter nr 0.32 Nr 0.32
over 200 but n e 300mm diameter nr 0.38 Nr 0.38
over 300 but n e 400mm diameter nr 0.46 Nr 0.46
n e 200mm diameter nr 0.28 Nr 0.28
over 200 but n e 300mm diameter nr 0.34 Nr 0.34
over 300 but n e 400mm diameter nr 0.39 Nr 0.39
n e 200mm diameter nr 0.25 Nr 0.25
over 200 but n e 300mm diameter nr 0.30 Nr 0.30
over 300 but n e 400mm diameter nr 0.33 Nr 0.33
100mm dia; in lengths ne 1.00m nr 0.21 Nr 0.21
150mm dia; in lengths ne 1.00m nr 0.24 Nr 0.24
200mm dia; in lengths ne 1.00m nr 0.26 Nr 0.26
300mm dia;in lengths ne 1.00m nr 0.39 Nr 0.39
400mm dia; in lengths ne 1.00m nr 0.47 Nr 0.47
450mm dia; in lengths ne 1.00m nr 0.52 Nr 0.52
Repair joint to concrete drain, irrespective of depth; reseal with approved material
Repair joint to clayware drain, and reseal with approved material
Repair joint to uPVC drain, and reseal with approved material
Repair damaged coating and wrapping to existing pipework; with pipe wrapping tape:
Repair
Search for, locate (by hand) expose drain run, excavate in short length, backfill excavated material, (repair of joint, break out and reinstatement of surfacing measured separately)
Search for; locate (by hand) and expose drain run, excavate in short length, backfill excavated material, (repair of joint, breaking out and reinstatement of surfacing measured separately)
Search for; locate (by hand) and expose drain run, excavate in short length, backfill excavated material, (repair of joint, breaking out and reinstatement of surfacing measured separately)
Repair joint to G R E drain, irrespective of depth; reseal with approved material
334
service; single pipe; n e 200mm dia pipe, 250mm ave depth m 0.30 ft 0.09
service; single pipe; n e 200mm dia pipe, 500mm ave depth m 0.30 ft 0.09
service; single pipe; n e 200mm dia pipe, 750mm ave depth m 0.41 ft 0.13
service; single pipe; n e 200mm dia pipe, 1000mm ave depth m 0.47 ft 0.14
service; two pipe cluster; n e 200mm dia pipe, 250mm ave depth m 0.33 ft 0.10
service; two pipe cluster; n e 200mm dia pipe, 500mm ave depth m 0.34 ft 0.10
service; two pipe cluster; n e 200mm dia pipe, 750mm ave depth m 0.44 ft 0.13
service; two pipe cluster; n e 200mm dia pipe, 1000mm ave depth m 0.50 ft 0.15
service; four pipe cluster; n e 200mm dia pipe, 250mm ave depth m 0.63 ft 0.19
service; four pipe cluster; n e 200mm dia pipe, 500mm ave depth m 0.64 ft 0.20
service; four pipe cluster; n e 200mm dia pipe, 750mm ave depth m 0.85 ft 0.26
service; four pipe cluster; n e 200mm dia pipe, 1000mm ave depth m 0.97 ft 0.30
service; eight pipe cluster; n e 200mm dia pipe, 250mm ave depth m 0.63 ft 0.19
service; eight pipe cluster; n e 200mm dia pipe, 500mm ave depth m 0.64 ft 0.20
service; eight pipe cluster; n e 200mm dia pipe, 750mm ave depth m 0.85 ft 0.26
service; eight pipe cluster; n e 200mm dia pipe, 1000mm ave depth m 0.97 ft 0.30Repair ductwork joint; irrespective of depth; reseal with approved material
PVC duct; n e 200mm dia m 0.56 ft 0.17
Breaking out and reinstatement of surfacing See NEW work rates
PVC manhole; area n e 0.1m2 nr 2.50 Nr 2.50
PVC manhole; area over 0.1m2 but n e 0.50m2 nr 2.50 Nr 2.50
bottom of brick manhole; area n e 0.1m2 nr 1.50 Nr 1.50
bottom of brick manhole; area over 0.1m2 but n e 0.5m2 nr 1.50 Nr 1.50
bottom of concrete manhole; area n e 0.1m2 nr 1.50 Nr 1.50
bottom of concrete manhole; area over 0.1m2 but n e 0.5m2 nr 1.50 Nr 1.50
manhole surface; internally; area n e 2.50m2 nr 5.00 Nr 5.00
manhole surface; internally; area over 2.50 but n e 3.00 m2 nr 5.70 Nr 5.70
manhole surface; internally; area over 3.00 but n e 4.00 m2 nr 6.60 Nr 6.60
manhole surface; internally; area not exceeding 0.5 m2 nr 3.00 Nr 3.00
manhole surface; internally; area over 0.5 but n e 1.00 m2 nr 5.00 Nr 5.00
manhole surface; internally; area over 1.0 m2 nr 7.50 Nr 7.50precast concrete drainage channel; internal dia 100mm dia nr 0.25 Nr 0.25
precast concrete drainage channel; internal dia 150mm dia nr 0.35 Nr 0.35
Clean down; prepare surface and apply GRE lining; vertical; forming around end of pipes; including all associated fixing to brickwork
Search for, excavate by hand in short length, locate and expose damaged ductwork, backfill excavated material, (repair of joint, breaking out and reinstatement of surfacing measured separately
Search for, locate and expose broken joint; repair with approved jointing, filling and sealing material
Clean down; prepare surface and apply GRE lining; horizontal or to slopes; including all associated fixing to concrete
Clean down and repair internal surface of manhole with approved sealing material
Clean down; break out damaged benching and reinstate benching with approved material around channelling to bottom of manhole
Clean down and break out damaged benching in bottom of concrete manhole and reinstate benching with approved material around channelling to bottom of manhole
335
250mm ave depth; pipe n e 200mm dia m 0.30 ft 0.09
500mm ave depth; pipe n e 200mm dia m 0.30 ft 0.09
750mm ave depth; pipe n e 200mm dia m 0.41 ft 0.13
1000mm ave depth; pipe n e 200mm dia m 0.47 ft 0.14
1250mm ave depth; pipe n e 200mm dia m 0.56 ft 0.17
1500mm ave depth; pipe n e 200mm dia m 0.68 ft 0.21
1750mm ave depth; pipe n e 200mm dia m 0.77 ft 0.23
2000mm ave depth; pipe n e 200mm dia m 0.85 ft 0.26
2250mm ave depth; pipe n e 200mm dia m 1.20 ft 0.37
2500mm ave depth; pipe n e 200mm dia m 1.31 ft 0.40
2750mm ave depth; pipe n e 200mm dia m 1.42 ft 0.43
3000mm ave depth; pipe n e 200mm dia m 1.53 ft 0.47
3250mm ave depth; pipe n e 200mm dia m 1.95 ft 0.59
3500mm ave depth; pipe n e 200mm dia m 2.11 ft 0.64
3750mm ave depth; pipe n e 200mm dia m 2.65 ft 0.81
4000mm ave depth; pipe n e 200mm dia m 2.78 ft 0.85
4250mm ave depth; pipe n e 200mm dia m 2.96 ft 0.90
4500mm ave depth; pipe n e 200mm dia m 3.14 ft 0.96
4750mm ave depth; pipe n e 200mm dia m 3.34 ft 1.02
5000mm ave depth; pipe n e 200mm dia m 3.51 ft 1.07
250mm ave depth; pipe over 200 but n e 300mm dia m 0.33 ft 0.10
500mm ave depth; pipe over 200 but n e 300mm dia m 0.34 ft 0.10
750mm ave depth; pipe over 200 but n e 300mm dia m 0.44 ft 0.13
1000mm ave depth; pipe over 200 but n e 300mm dia m 0.50 ft 0.15
1250mm ave depth; pipe over 200 but n e 300mm dia m 0.59 ft 0.18
1500mm ave depth; pipe over 200 but n e 300mm dia m 0.71 ft 0.22
1750mm ave depth; pipe over 200 but n e 300mm dia m 0.80 ft 0.24
2000mm ave depth; pipe over 200 but n e 300mm dia m 0.88 ft 0.27
2250mm ave depth; pipe over 200 but n e 300mm dia m 1.23 ft 0.38
2500mm ave depth; pipe over 200 but n e 300mm dia m 1.34 ft 0.41
2750mm ave depth; pipe over 200 but n e 300mm dia m 1.45 ft 0.44
3000mm ave depth; pipe over 200 but n e 300mm dia m 1.56 ft 0.48
3250mm ave depth; pipe over 200 but n e 300mm dia m 1.98 ft 0.60
3500mm ave depth; pipe over 200 but n e 300mm dia m 2.14 ft 0.65
3750mm ave depth; pipe over 200 but n e 300mm dia m 2.68 ft 0.82
4000mm ave depth; pipe over 200 but n e 300mm dia m 2.81 ft 0.86
4250mm ave depth; pipe over 200 but n e 300mm dia m 2.99 ft 0.91
4500mm ave depth; pipe over 200 but n e 300mm dia m 3.17 ft 0.97
4750mm ave depth; pipe over 200 but n e 300mm dia m 3.37 ft 1.03
5000mm ave depth; pipe over 200 but n e 300mm dia m 3.54 ft 1.08
250mm ave depth; pipe over 300 but n e 400mm dia m 0.33 ft 0.10
500mm ave depth; pipe over 300 but n e 400mm dia m 0.34 ft 0.10
750mm ave depth; pipe over 300 but n e 400mm dia m 0.44 ft 0.13
1000mm ave depth; pipe over 300 but n e 400mm dia m 0.50 ft 0.15
1250mm ave depth; pipe over 300 but n e 400mm dia m 0.59 ft 0.18
1500mm ave depth; pipe over 300 but n e 400mm dia m 0.71 ft 0.22
1750mm ave depth; pipe over 300 but n e 400mm dia m 0.80 ft 0.24
2000mm ave depth; pipe over 300 but n e 400mm dia m 0.88 ft 0.27
2250mm ave depth; pipe over 300 but n e 400mm dia m 1.23 ft 0.38
2500mm ave depth; pipe over 300 but n e 400mm dia m 1.34 ft 0.41
2750mm ave depth; pipe over 300 but n e 400mm dia m 1.45 ft 0.44
3000mm ave depth; pipe over 300 but n e 400mm dia m 1.56 ft 0.48
3250mm ave depth; pipe over 300 but n e 400mm dia m 1.98 ft 0.60
3500mm ave depth; pipe over 300 but n e 400mm dia m 2.14 ft 0.65
3750mm ave depth; pipe over 300 but n e 400mm dia m 2.68 ft 0.82
4000mm ave depth; pipe over 300 but n e 400mm dia m 2.81 ft 0.86
4250mm ave depth; pipe over 300 but n e 400mm dia m 2.99 ft 0.91
4500mm ave depth; pipe over 300 but n e 400mm dia m 3.17 ft 0.97
4750mm ave depth; pipe over 300 but n e 400mm dia m 3.37 ft 1.03
5000mm ave depth; pipe over 300 but n e 400mm dia m 3.54 ft 1.08
service; single pipe; n e 200mm dia pipe, 250mm ave depth m 0.30 ft 0.09
service; single pipe; n e 200mm dia pipe, 500mm ave depth m 0.30 ft 0.09
service; single pipe; n e 200mm dia pipe, 750mm ave depth m 0.41 ft 0.13
service; single pipe; n e 200mm dia pipe, 1000mm ave depth m 0.47 ft 0.14
service; two pipe cluster; n e 200mm dia pipe, 250mm ave depth m 0.33 ft 0.10
service; two pipe cluster; n e 200mm dia pipe, 500mm ave depth m 0.34 ft 0.10
service; two pipe cluster; n e 200mm dia pipe, 750mm ave depth m 0.44 ft 0.13
service; two pipe cluster; n e 200mm dia pipe, 1000mm ave depth m 0.50 ft 0.15
service; four pipe cluster; n e 200mm dia pipe, 250mm ave depth m 0.63 ft 0.19
service; four pipe cluster; n e 200mm dia pipe, 500mm ave depth m 0.64 ft 0.20
service; four pipe cluster; n e 200mm dia pipe, 750mm ave depth m 0.85 ft 0.26
service; four pipe cluster; n e 200mm dia pipe, 1000mm ave depth m 0.97 ft 0.30
service; eight pipe cluster; n e 200mm dia pipe, 250mm ave depth m 0.63 ft 0.19
service; eight pipe cluster; n e 200mm dia pipe, 500mm ave depth m 0.64 ft 0.20
service; eight pipe cluster; n e 200mm dia pipe, 750mm ave depth m 0.85 ft 0.26
service; eight pipe cluster; n e 200mm dia pipe, 1000mm ave depth m 0.97 ft 0.30
pipe; n e 200mm dia m 0.59 ft 0.18
pipe; over 200 but n e 300mm dia m 0.71 ft 0.22
pipe; over 300 but n e 400mm dia m 0.81 ft 0.25
pipe; n e 200mm dia m 0.93 ft 0.28
pipe; over 200 but n e 300mm dia m 1.03 ft 0.31
pipe; over 300 but n e 400mm dia m 1.19 ft 0.36
pipe; n e 200mm dia m 0.67 ft 0.20
pipe; over 200 but n e 300mm dia m 0.79 ft 0.24
pipe; over 300 but n e 400mm dia m 0.95 ft 0.29
pipe; n e 200mm dia m 0.56 ft 0.17
pipe; over 200 but n e 300mm dia m 0.63 ft 0.19
pipe; over 300 but n e 400mm dia m 0.69 ft 0.21
pipe; n e 200mm dia m 0.26 ft 0.08
pipe; over 200 but n e 300mm dia m 0.33 ft 0.10
pipe; over 300 but n e 400mm dia m 0.39 ft 0.12
Break joint and remove length of broken GRE drain, irrespective of depth; relay with new pipework, rejoint and reseal with approved material
Search for, excavate (part by machine), locate and expose ductwork, backfill excavated material, (remove pipework; breakout and reinstate surface measured separately)
Search for, excavate (part by machine), locate and expose pipework, backfill excavated material, (remove pipework; breakout and reinstate surface measured separately)
Search for, excavate (part by machine), locate and expose pipework, backfill excavated material, (remove pipework; breakout and reinstate surface measured separately)
Search for, excavate (part by machine), locate and expose pipework, backfill excavated material, (remove pipework; breakout and reinstate surface measured separately)
Break joint and remove length of broken clayware drain, irrespective of depth; relay with new pipework, rejoint and reseal with approved material
Break joint and remove length of broken uPVC drain, irrespective of depth; relay with new pipework, rejoint and reseal with approved material
Break joint and remove length of broken porous field drain, irrespective of depth; relay with new pipework, rejoint and reseal with approved material
Replace
Break joint and remove length of broken concrete drain, irrespective of depth; relay with new pipework, rejoint and reseal with approved material
336
Repair joint; see repair
Breaking out and reinstatement of surfacing. See NE W work rates
Demolition and removal only. Replacement of manholes, gullies and channels as NEW Work items
Demolish and remove existing PVC manhole break up concrete bed and surround
internal volume n. e 1.00m3 nr 0.75 Nr 0.75
internal volume n e 1.00m3 nr 1.00 Nr 1.00
internal volume over 1.00m3 but ne 2.50m3 nr 1.35 Nr 1.35
internal volume over 2.50m3 but n e 4.00m3 nr 1.70 Nr 1.70
internal volume over 4.00m3 but n e 5.50m3 nr 2.05 Nr 2.05
internal volume over 5.50m3 but n e 7.00m3 nr 2.40 Nr 2.40
internal volume over 7.00m3 but n e 8.50m3 nr 2.75 Nr 2.75
internal volume over 8.50m3 but n e 10.00m3 nr 3.10 Nr 3.10
internal volume over 10.00m3 nr 3.45 Nr 3.45
internal volume n e 1.00m3 nr 1.00 Nr 1.00
internal volume over 1.00m3 but ne 2.50m3 nr 1.35 Nr 1.35
internal volume over 2.50m3 but n e 4.00m3 nr 1.70 Nr 1.70
internal volume over 4.00m3 but n e 5.50m3 nr 2.05 Nr 2.05
internal volume over 5.50m3 but n e 7.00m3 nr 2.40 Nr 2.40
internal volume over 7.00m3 but n e 8.50m3 nr 2.75 Nr 2.75
internal volume over 8.50m3 but n e 10.00m3 nr 3.10 Nr 3.10
internal volume over 10.00m3 nr 3.45 Nr 3.45
rainwater gully; 100mm dia outlet; 150 x 150mm cast iron grating nr 0.25 Nr 0.25
rainwater gully; 150mm dia outlet; 225 x 225mm cast iron grating nr 0.27 Nr 0.27road gully; 300mm dia x 600mm deep; 150mm dia outlet; inspection eye; 225 x 225mm cast iron grating
nr 0.35 Nr 0.35
road gully; 450mm dia x 900mm deep to BS 556; 150mm dia outlet; rodding eye and stopper
nr 0.65 Nr 0.65
precast concrete channel; internal 100mm dia m 0.38 ft 0.12
Precast concrete channel; internal 150mm dia m 0.39 ft 0.12
pipe 100mm dia m 0.15 ft 0.05
pipe 150mm dia m 0.20 ft 0.06
pipe 200mm dia m 0.25 ft 0.08
pipe 300mm dia m 0.35 ft 0.11
pipe 400mm dia m 0.40 ft 0.12
pipe 450mm dia m 0.45 ft 0.14
Break out and remove existing drain fitting, concrete bed and haunching.
Carefully remove coating and wrapping to pipework; clean down exposed surface
Demolish and remove existing brickwork manhole, break up concrete bed, channelling and benching
Demolish and remove existing circular precast concrete manhole, break up concrete bed, channelling and benching
Break out and remove existing precast concrete drainage channel, bed and haunching
337
Q.2.1.9 Roads, Paving & Fencing
m 0.13 ft 0.04
m 0.21 ft 0.06
extra forming quadrant Nr 0.43 Nr 0.43
extra forming angle Nr 0.43 Nr 0.43
extra forming dropper kerb; Nr 0.10 Nr 0.10
m 0.14 ft 0.04
m 0.21 ft 0.06
m3 1.44 yd3 1.10
m3 2.41 yd3 1.84
m3 2.29 yd3 1.75
foundation to kerb, edging or channel; n e 150mm thick; sloping n e 15 degrees from horizontal; poured on or against earth or unblinded hardcore
m3 1.59 yd3 1.22
Formwork;
edge of bed; over 1.00m high m2 0.67 ft2 0.06
edge of bed; n e 250 high m 0.29 ft 0.09
edge of bed; over 250 but n e 500 high m 0.52 ft 0.16
edge of bed; over 500 but n e 1.00m high m 0.67 ft 0.20
edge of foundation to kerb, edging or channel; over 1.00m high m3 0.75 yd3 0.58edge of foundation to kerb, edging or channel; not exceeding 250 high m 0.33 ft 0.10
edge of foundation to kerb, edging or channel; over 250 but n e 500mm high
m 0.42 ft 0.13
edge of foundation to kerb, edging or channel, over 500 but n e 1.00m high
m 0.75 ft 0.23
Reinforcement;Lay reinforcement; Fabric - A252 bed m2 0.09 ft2 0.01Lay reinforcement; Fabric - A193 bed m2 0.09 ft2 0.01
Labours to concrete work
tamping by mechanical means m2 0.04 ft2 0.00
trowelling m2 0.09 ft2 0.01
trowel and brush finish m2 0.13 ft2 0.01
floated finish m2 0.09 ft2 0.01
percentage adjustment on worked finish for sloping concrete % % 0.00
percentage adjustment on worked finish for sloping to falls % % 0.00
percentage adjustment on worked finish for working to crossfalls % % 0.00
Surface treatments
road or paving; 60mm thick; level or to falls m2 0.08 ft2 0.01
road or paving; 60mm thick; falls and crossfalls m2 0.09 ft2 0.01
road or paving; 60mm thick; slopes over 15 degrees from horizontal m2 0.08 ft2 0.01
road or paving 40mm thick; level or to falls m2 0.02 ft2 0.00
road or paving 40mm thick; falls and crossfalls and to slopes m2 0.02 ft2 0.00
road or paving 40mm thick; slopes over 15 degrees from horizontal m2 0.02 ft2 0.00
road or paving; 19mm thick; levels or to falls m2 0.05 ft2 0.00
road or paving; 19mm thick; falls and crossfalls m2 0.16 ft2 0.02
road or paving; 19mm thick; slopes over 15 degrees from horizontal m2 0.17 ft2 0.02
road or paving; 75mm thick; level or to falls m2 0.16 ft2 0.01
road or paving; 75mm thick; falls and crossfalls m2 0.16 ft2 0.01
road or paving; 75mm thick; slopes over 15 degrees from horizontal m2 0.16 ft2 0.01
extra over for 12mm pre-coated chippings to surface m2 0.00 ft2 0.00
road; level or to falls; stretcher bond m2 0.47 ft2 0.04
road; level or to falls; herringbone pattern m2 0.49 ft2 0.05
road; falls and crossfalls; stretcher bond m2 0.50 ft2 0.05road; falls and crossfalls; herringbone pattern m2 0.62 ft2 0.06
road; slopes over 15 degrees from horizontal; stretcher bond m2 0.60 ft2 0.06
road; slopes over 15 degrees from horiztonal; herringbone pattern m2 0.64 ft2 0.06paving; level or to falls; stretcher bond m2 0.47 ft2 0.04
paving; level or to falls; herringbone pattern m2 0.49 ft2 0.05paving; falls and crossfalls; stretcher bond m2 0.50 ft2 0.05
paving; falls and crossfalls; herringbone pattern m2 0.62 ft2 0.06
paving; slopes over 15 degrees from horizontal; stretcher bond m2 0.60 ft2 0.06
paving; slopes over 15 degrees from horiztonal; herringbone pattern m2 0.64 ft2 0.06
ROADS, PAVINGS AND FENCING
Erect formwork and remove; vertical
Lay precast concrete unit; including foundation and haunching in plain insitu concrete.
lay; Macadam; bitumen base course
Norm Hrs. IMPERIAL
Lay; Macadam; bitumen wearing course
150 x 50mm round top edging; foundation 250 x 150mm; haunching one side; curved radius up to 12m
Lay; Macadam; one coat
Lay; 190 x 90 x 65mm brick pavior; bed of sand 50mm thick; jointing with sand brushed into pavior joint; vibrated
Norm Hrs. METRIC
Lay; reinforced concrete; grade C40; (reinforcement measured separately)
New Works
half battered kerb size 255 x 125mm; foundation 450 x 150mm; haunching one side
half battered kerb size 255 x 125mm; foundation 450 x 150mm; curved radius up to 12m haunching one side
150 x 50mm round top edging; foundation 250 x 150mm; haunching one side
bed; n e 150mm thick; sloping n e 15 degrees from horizontal; poured on or against earth or unblinded hardcore
Treating surface of unset concrete
bed; over 450mm thick n e 15 degrees from horizontal; poured on or against earth or unblinded hardcore
bed; over 150 but n e 450mm thick sloping n e 15 degrees from horizontal; poured on or against earth or unblinded hardcore
338
paving with cobbles size 50 to 75mm thick; random; level or to falls m2 3.70 ft2 0.34
paving with cobbles size 50 to 75mm thick; random; to falls and crossfalls
m2 3.70 ft2 0.34
paving with cobbles size 50 to 75mm thick; random; slopes over 15 degrees from horizontal
m2 3.70 ft2 0.34
paving with cobbles size 50 to 75mm thick; pattern; level or to falls m2 4.63 ft2 0.43
paving with cobbles size 50 to 75mm thick; pattern; to falls and crossfalls m2 4.63 ft2 0.43paving with cobbles size 50 to 75mm thick; pattern; slopes over 15 degrees from horizontal
m2 4.63 ft2 0.43
paving 50mm thick; level or to falls m2 0.07 ft2 0.01
paving 50mm thick; falls or to crossfalls m2 0.07 ft2 0.01paving 50mm thick; slopes over 15 degrees from horizontal m2 0.07 ft2 0.01
paving 150mm thick; level or to falls m2 0.03 ft2 0.00
paving 150mm thick; falls or to crossfalls m2 0.03 ft2 0.00
paving; level or to falls, half slab bond m2 0.20 ft2 0.02
paving; falls and crossfalls; half slab bond m2 0.21 ft2 0.02
paving; slopes over 15 degrees from horizontal; half slab bond m2 0.39 ft2 0.04
paving; level or to falls, half slab bond m2 0.22 ft2 0.02
paving; falls and crossfalls; half slab bond m2 0.23 ft2 0.02
paving; slopes over 15 degrees from horizontal; half slab bond m2 0.44 ft2 0.04
general surface; slope n e 15 deg m2 0.05 ft2 0.00
cutting or embankment m2 0.05 ft2 0.00
Prepare surface; apply one coat line marking; road and paving; width n e 300mm m 0.04 ft 0.01
posts at 3.00m centres; fencing 2500mm high m 1.25 ft 0.38
single rail; posts at 3.00m centres m 0.75 ft 0.23
double rail; posts at 5.00m centres m 0.85 ft 0.26
n e 500mm girth; 900mm high nr 0.60 Nr 0.60
over 500mm girth; 900mm high nr 0.60 Nr 0.60
Erect road sign metal and support post; set in concrete foundation; including all necessary excavation; remove surplus material to agreed location on site
63mm dia; 2500mm long nr 0.60 Nr 0.60
n e 500mm girth; 5.00m long nr 1.25 Nr 1.25
n e 500mm girth; 10.00m long nr 1.25 Nr 1.25
Erect bollard metal or precast concrete; set in concrete foundation; including all necessary excavation; remove surplus material to agreed location on site
Erect crash barrier; galvanised metal; galvanised metal posts; set in concrete foundation; including all necessary excavation; remove surplus material to agreed location on site
Erect lighting column; set in concrete foundation; including all necessary excavation; remove surplus material to agreed location on site
Lay paving; concrete slab; 600 x 600mm; bedding and jointing in cement mortar(1:3)
Lay paving; concrete slab; 900 x 600mm; bedding and jointing in cement mortar (1:3)
Lay; Washed cobblestone; bedding in cement mortar (1:3); jointing to a height of two thirds of cobbles in dry mortar (1:3); tightly butted, washed and brushed finish; to concrete
Lay gravel paving; two coat; base layer course clinker aggregate; wearing layer fine gravel aggregate
Prepare surface, cultivate and sow grass seed comprising 80% S23 rye grass and 20% chewing fescue at the rate of 0.07kg per sq. m
Erect rigid heavy weld mesh fence panel, galvanised wire and high build bonded polyester coating; galvanised metal posts; set in concrete foundation; including all necessary excavation; remove surplus material to agreed location on site;
Lay hardstanding; broken brickwork or concrete filling; top surface blinded with fine material;
surface of ground; level m2 0.01 ft2 0.00
surface of ground; slopes m2 0.01 ft2 0.00
surface of ground; level m2 0.02 ft2 0.00
surface of ground; slopes m2 0.02 ft2 0.00
Surface; level or to falls m2 0.01 ft2 0.00
Surface; falls and crossfalls m2 0.01 ft2 0.00
Clean
Apply approved weedkiller
Cut grass; machine
Clean down with machine; road or paving; approved cleaning agent
339
tarmac road; area n e 1.00m2 m2 0.12 ft2 0.01
brick paving; area n e 1.00m2 m2 1.15 ft2 0.11
concrete paving; area n e 1.00m2 m2 0.16 ft2 0.01
hardstanding; area n e 1.00m2 m2 0.07 ft2 0.01
precast concrete slab paving; 900 x 600mm; area n e 5.00m2 m2 0.22 ft2 0.02
precast concrete slab paving; 600 x 600mm; area n e 5.00m2 m2 0.25 ft2 0.02cobblestone paving; random; area n e 1.00m2 m2 1.18 ft2 0.11
cobblestone paving; pattern; area n e 1.00m2 m2 1.47 ft2 0.14
gravel paving; area n e 1.00m2 m2 0.09 ft2 0.01
precast concrete kerb; foundation 450 x 150; length n e 5.00m m 0.23 ft 0.07
precast concrete edging; foundation 450 x 150; length n e 5.00m m 0.24 ft 0.07
hole; n e 0.10m2 nr 0.20 Nr 0.20
hole; over 0.10 but n e 0.50m2 nr 0.30 Nr 0.30
hole; over 0.50 but n e 1.00m2 nr 0.40 Nr 0.40
mesh panel fencing and supports at 3.00m centres; 2500mm high m 0.75 ft 0.23
single rail; crash barrier and support at 3.00m centres; length n e 5.00m m 0.45 ft 0.14
double rail; crash barrier and support at 5.00m centres; length n e 5.00m m 0.55 ft 0.17
crash barrier on supports at 3.00m centres; length n e 5.00m m 0.09 ft 0.03
precast concrete or metal bollard; nr 2.25 Nr 2.25
low level metal lighting bollard nr 3.15 Nr 3.15
high level metal lighting column nr 4.25 Nr 4.25
low level metal lighting bollard; broken lighting enclosure and lamp; nr 0.33 Nr 0.33
high level metal lighting column; broken lighting enclosure and lamp nr 0.33 Nr 0.33
vertical; mesh fencing panel; (including supports) m2 0.20 ft2 0.02
lighting column and bollard; girth over 500 but n e 750mm m 0.24 ft 0.07
lighting column and bollard; girth over 750 but n e 1000mm m 0.29 ft 0.09
Breaking out and reinstatement of surfacing See NEW work rates
Take up loose or uneven material; set aside for reuse; relevel subbase under and reinstate surfacing with material set aside or replace with new; jointed and pointed with approved material
Repair mesh panel fencing; reforming mesh; welding
Clean down prepare and apply painting system to metal
Carefully dismantle and set aside mesh panel fencing; remove and set aside support; break up and lay concrete foundation under; reinstall
Carefully dismantle crash barrier; take up support; break up and lay concrete foundation under, reinstall
Remove loose material, repair uneven level in surfacing with approved material, finished flush with existing to falls
Repair
Take up precast concrete unit and set aside, break up and lay concrete foundation under and relay, jointed and pointed in approved material
Carefully dismantle crash barrier from support post, repair and refix to support post
Carefully disconnect; isolate electrical supply, remove and set aside, replace with approved material and reconnect electrical supply
Carefully take up and set aside, break up and lay concrete foundation under and relay, jointed and pointed in approved material
Carefully disconnect and isolate electrical supply, take up and set aside, relevel foundation under; relay, and reconnect electrical supply
Removal only. For replacement use New Rates
tarmac road or paving and subbase; level or to falls and crossfalls m3 0.85 yd3 0.65
reinforced concrete road or paving and subbase; level or to falls and crossfallsm3 0.85 yd3 0.65
hardstanding; level or to falls and crossfalls m3 0.17 yd3 0.13Scarify surface; machine tarmac road or paving; 25mm thick; level or to falls and crossfalls m2 0.07 ft2 0.01
m2 0.35 ft2 0.03
m2 0.35 ft2 0.03
cobblestone paving and subbase; level or to falls and crossfalls m2 0.35 ft2 0.03precast concrete half battered kerb 255 x 125mm; 450 x 150mm thick foundation
m 0.47 ft 0.14
precast concrete round top edging 150 x 50mm; 250 x 150mm thick foundation
m 0.37 ft 0.11
Burn off from road surfacing, clean surface line marking; n e 300mm wide m 0.03 ft 0.01mesh panel fencing; support posts at 3.00m centres; 2500mm high; set aside
m 0.15 ft 0.05
single rail; crash barrier and support post at 3.00m centres, set aside m 0.25 ft 0.08
double rail; crash barrier and support post at 5.00m centres, set aside m 0.30 ft 0.09Disconnect service and withdraw from duct, search for, excavate, locate and expose broken length of duct pipework, remove ductwork
service cable supply m 0.65 ft 0.20
concrete or metal bollard; set aside Nr 1.30 Nr 1.30
road sign; set aside nr 1.30 Nr 1.30
low level metal lighting bollard; set aside nr 0.95 Nr 0.95high level metal lighting column; set aside nr 1.15 Nr 1.15
brickwork draw pit nr 2.50 Nr 2.50
Grub up and remove to an agreed location on site bush or tree nr 0.50 Nr 0.50
concrete slab paving 50mm thick and subbase; level or to falls and crossfalls
brick road or paving 65mm thick and sand subbase; level or to falls and crossfalls
Break up and remove to an agreed location on site;
Take up and remove to an agreed location on site;
Take up and remove to an agreed location on site; including break up concrete foundation and haunching.
Replace
Carefully dismantle; break up concrete foundation and remove to an agreed location on site;
Disconnect and isolate service, demolish, break up concrete bed and remove to an agreed location on site.
Carefully dismantle; break up concrete foundation and remove to an agreed location on site;
Dismantle; break up concrete foundation and remove to an agreed location on site
Carefully disconnect and isolate electrical supply, dismantle, break up concrete foundation and remove to an agreed location on site
340
Q.2.1 Building Norms
Q.2.2.1 Demolitions & Alterations
DEMOLITIONassumed to be 'one off' items
STRUCTURES
structural steelwork; frame n e 10m height t 0.15 t 0.14
structural steelwork; frame over 10 but n e 15m overall height t 0.16 t 0.15
structural steelwork; frame over 15 but n e 20m overall height t 0.17 t 0.15
structural steelwork; frame over 20 but n e 25m overall height t 0.18 t 0.16
structural steelwork; frame over 25 but n e 30m overall height t 0.19 t 0.17
structural steelwork; frame over 30 but n e 35m overall height t 0.20 t 0.18
structural steelwork; frame over 35 but n e 40m overall height t 0.21 t 0.19
structural steelwork; frame over 40m overall height t 0.22 t 0.20
reinforced concrete work; n e 10m3 overall volume m3 0.90 yd3 0.69
reinforced concrete work; over 10 but n e 25m3 overall volume m3 0.85 yd3 0.65
reinforced concrete work; over 25 but n e 50m3 overall volume m3 0.80 yd3 0.61
reinforced concrete work; over 50m3 overall volume m3 0.75 yd3 0.57
brickwork or blockwork; n e 10m3 overall volume m3 0.53 yd3 0.40
brickwork or blockwork; over 10 but n e 25m3 overall volume m3 0.48 yd3 0.37
brickwork or blockwork; over 25 but n e 50m3 overall volume m3 0.43 yd3 0.33
brickwork or blockwork; over 50m3 overall volume m3 0.38 yd3 0.29
ALTERATION
FORMING OPENING:
EXTERNALLY
concrete suspended floor; n e 150mm thick; area n e 2.00m2 nr 3.25 nr 3.25
nr 4.50 nr 4.50
concrete wall; n e 150mm thick; area n e 2.00m2 nr 3.25 nr 3.25
concrete wall over 150 but n e 450mm thick; area n e 2.00m2 nr 4.50 nr 4.50
half brick wall; n e 2.00m2 nr 1.65 nr 1.65
one brick wall; n e 2.00m2 nr 2.65 nr 2.65
one brick wall; opening size; 900 x 450 mm nr 5.57 nr 5.57
one brick wall; opening size; 900 x 900 mm nr 5.57 nr 5.57
one brick wall; opening size; 900 x 2100 mm nr 7.42 nr 7.42
one brick wall; opening size 1800 x 2100mm nr 12.25 nr 12.25
275mm thick cavity wall; opening size 900 x 450 mm nr 7.24 nr 7.24
275mm thick cavity wall; opening size 900 x 900 mm nr 7.24 nr 7.24
275mm thick cavity wall; opening size 900 x 2100 mm nr 10.53 nr 10.53
275mm thick cavity wall; opening size 1800 x 2100mm nr 15.53 nr 15.53
wall metal profiled cladding; opening size 900 x 450 mm nr 2.75 nr 2.75
wall metal profiled cladding; opening size 900 x 900 mm nr 3.57 nr 3.57
wall metal profiled cladding; opening size 900 x 2100 mm nr 5.42 nr 5.42
wall metal profiled cladding; opening size 1800 x 2100 mm nr 7.85 nr 7.85
roof metal profiled decking; opening size 600 x 900 mm nr 3.17 nr 3.17
roof metal profiled decking; opening size 900 x 900 mm nr 3.57 nr 3.57
roof metal profiled decking; opening size 900 x 1200 mm nr 3.94 nr 3.94
roof metal profiled decking; opening size 1200 x 1200 mm nr 4.26 nr 4.26
INTERNALLY
half brick wall; opening size 900 x 450 mm nr 4.84 nr 4.84
half brick wall; opening size 900 x 900 mm nr 4.84 nr 4.84
half brick wall; opening size 900 x 2100 mm nr 7.42 nr 7.42
half brick wall; opening size 1800 x 2100 mm nr 9.25 nr 9.25
one brick wall; opening size 900 x 450 mm nr 5.57 nr 5.57
one brick wall; opening size 900 x 900 mm nr 5.57 nr 5.57
one brick wall; opening size 900 x 2100 mm nr 8.54 nr 8.54
one brick wall; opening size 1800 x 2100 mm nr 11.95 nr 11.95
100mm block wall; opening size 900 x 450 mm nr 3.37 nr 3.37
100mm block wall; opening size 900 x 900 mm nr 3.37 nr 3.37
100mm block wall; opening size 900 x 2100 mm nr 5.63 nr 5.63
100mm block wall; opening size 1800 x 2100 mm nr 7.34 nr 7.34
140mm block wall; opening size 900 x 450 mm nr 4.10 nr 4.10
140mm block wall; opening size 900 x 900 mm nr 4.10 nr 4.10
140mm block wall; opening size 900 x 2100 mm nr 7.21 nr 7.21
140mm block wall; opening size 1800 x 2100 mm nr 9.13 nr 9.13
half brick wall; opening size 900 x 450 mm nr 5.31 nr 5.31
half brick wall; opening size 900 x 900 mm nr 5.31 nr 5.31
half brick wall; opening size 900 x 2100 mm nr 8.15 nr 8.15
half brick wall; opening size 1800 x 2100 mm nr 11.15 nr 11.15
DEMOLITIONS AND ALTERATIONS
Dismantle and remove
Demolish and remove
Break out for new door opening; making good all round; including provision maintenance and removal of temporary screens and support; remove all debris
Norm Hrs. IMPERIAL
Norm Hrs. METRIC
New Work
Break out or form opening; making good all round; including provision, maintenance and removal of temporary screens and support; remove all debris concrete suspended floor; over 150 but n e 450mm thick; area n e
2.00m2
Form opening; making good plaster to one side; facework to other side; including provision maintenance and removal of temporary screens and support; remove all debris
From opening; closing cavity at jambs with brickwork; damp proof course all round; including provision maintenance and removal of temporary screens and support; remove all debris
Form opening; insert concrete or metal lintel wedge and pin; quoin up jambs; make good plaster or plasterboard lining to both sides; including provision maintenance and removal of temporary screens and support; remove all debris
Form opening; provide and fix support steelwork and trimming to all sides; make good internal finish; including provision maintenance and removal of temporary screens and support; remove all debris
Form opening; insert concrete or metal lintel wedge and pin; quoin up jambs; make good facework to both sides; including provision maintenance and removal of temporary screens and support; remove all debris
341
one brick wall; opening size 900 x 450 mm nr 5.57 nr 5.57
one brick wall; opening size 900 x 900 mm nr 5.57 nr 5.57
one brick wall; opening size 900 x 2100 mm nr 7.42 nr 7.42
one brick wall; opening size 1800 x 2100 mm nr 11.95 nr 11.95
100mm block wall; opening size 900 x 450 mm nr 3.37 nr 3.37
100mm block wall; opening size 900 x 900 mm nr 3.37 nr 3.37
100mm block wall; opening size 900 x 2100 mm nr 5.63 nr 5.63
100mm block wall; opening size 1800 x 2100 mm nr 7.34 nr 7.34
140mm block wall; opening size 900 x 450 mm nr 4.10 nr 4.10
140mm block wall; opening size 900 x 900 mm nr 4.10 nr 4.10
140mm block wall; opening size 900 x 2100 mm nr 7.21 nr 7.21
140mm block wall; opening size 1800 x 2100 mm nr 9.13 nr 9.13
62.5mm thick stud partition; opening size 900 x 450 mm nr 2.40 nr 2.40
62.5mm thick stud partition; opening size 900 x 900 mm nr 3.00 nr 3.00
62.5mm thick stud partition; opening size 900 x 2100 mm nr 4.74 nr 4.74
62.5mm thick stud partition; opening size 1800 x 2100 mm nr 5.62 nr 5.62
80mm thick stud partition; opening size 900 x 450 mm nr 2.40 nr 2.40
80mm thick stud partition; opening size 900 x 900 mm nr 3.00 nr 3.00
80mm thick stud partition; opening size 900 x 2100 mm nr 4.74 nr 4.74
80mm thick stud partition; opening size 1800 x 2100 mm nr 5.62 nr 5.62
100mm thick stud partition; opening size 900 x 450 mm nr 2.40 nr 2.40
100mm thick stud partition; opening size 900 x 900 mm nr 3.00 nr 3.00
100mm thick stud partition; opening size 900 x 2100 mm nr 4.74 nr 4.74
100mm thick stud partition; opening size 1800 x 2100 mm nr 5.62 nr 5.62
window or door set; opening size 900 x 450 mm nr 0.33 nr 0.33
window or door set; opening size 900 x 900 mm nr 0.38 nr 0.38
window or door set; opening size 900 x 2100 mm nr 0.65 nr 0.65
window or door set; opening size 1800 x 2100mm nr 0.97 nr 0.97
FILLING OPENING
EXTERNALLY
half brick wall m2 1.62 ft2 0.15
half brick skin of hollow wall m2 1.62 ft2 0.15
one brick wall m2 2.92 ft2 0.27
one and a half brick wall m2 3.73 ft2 0.35
half brick wall m2 1.94 ft2 0.18
one brick wall m2 3.55 ft2 0.33
wall cladding m2 1.00 ft2 0.09
roof decking m2 1.45 ft2 0.13
INTERNALLY
concrete suspended floor; n e 150mm thick m2 1.96 ft2 0.18
concrete suspended floor; over 150 but n e 450mm thick m2 1.75 ft2 0.16
concrete wall; n e 150mm thick m2 2.84 ft2 0.26
concrete wall; over 150 but n e 450mm thick m2 2.63 ft2 0.24
concrete wall; n e 150mm thick m2 2.96 ft2 0.28
concrete wall; over 150 but n e 450mm thick m2 2.75 ft2 0.26
100 mm thick wall m2 1.00 ft2 0.09
140 mm thick wall m2 1.00 ft2 0.09
62.5mm thick stud partition; m2 1.25 ft2 0.12
80mm thick stud partition m2 1.30 ft2 0.12
100mm thick stud partition m2 1.40 ft2 0.13
Surface Treatment
facing brickwork m2 0.28 ft2 0.03
engineering brickwork m2 0.42 ft2 0.04
half brick wall m 0.11 ft 0.03
one brick wall m 0.18 ft 0.05
Fill opening; engineering brickwork in cement mortar (1:3); cut, tooth and bond to existing
Fill opening; metal profiled sheeting; including removal of sheeting cut to form opening; refix with complete sheets to match existing
Form opening; insert concrete or metal lintel wedge and pin; quoin up jambs; make good facework to both sides; including provision maintenance and removal of temporary screens and support; remove all debris
Form opening; trim studwork around opening; make good plasterboard and timber skirting both sides; including provision maintenance and removal of temporary screens and support; remove all debris
Fill opening; plasterboard lining to both sides; finished to match existing
Prepare top of existing wall to receive new brickwork or blockwork
Fill opening; facing brickwork in cement mortar(1:3), pointed one side; cut, tooth and bond to existing
Fill opening; concrete blockwork in cement mortar(1:8) with added plasticiser; cut tooth and bond to existing
Fill opening; plain insitu concrete to achieve required strength; including erect, dismantle and remove vertical formwork; finished flush with existing
Fill opening; reinforced insitu concrete to achieve required strength; including fixing mesh fabric reinforcement; erect, dismantle and remove vertical formwork; finished flush with existing.
Hack face; form surface to receive new application
See also Civil - Concretework and Masonry - Repair for other surface treatment items
Fill opening; reinforced insitu to achieve required stength; including fixing mesh fabric reinforcement; erect, dismantle and remove vertical formwork; finished flush with existing.
Carefully remove and dispose; existing metal or timber unit; irrespective of thickness or material; including preparing jambs, cill and soffit to receive infill. (Infill measured separately)
Clean
Not applicable - see alteration items new work
Repair
Not applicable
Replace
Not applicable - See alteration new work
342
Q.2.2.2 Roof Decking & Wall Cladding
Roof structure - timberjoist size 38 x 75 mm m 0.05 ft 0.02
joist size 38 x 100 mm m 0.06 ft 0.02
joist size 38 x 150 mm m 0.08 ft 0.03
joist size 50 x 75 mm m 0.05 ft 0.02
joist size 50 x 150 mm m 0.09 ft 0.03
joist size 75 x 175 mm m 0.16 ft 0.05
herringbone size 50 x 50mm; between 150 mm joists m 0.25 ft 0.08
herringbone size 50 x 50mm; between 175 mm joists m 0.25 ft 0.08
herringbone size 50 x 50mm; between 225 mm joists m 0.25 ft 0.08
solid size 50 x 150 mm m 0.25 ft 0.07
solid size 50 x 225 mm m 0.28 ft 0.09
rafter size 25 x 125 mm m 0.08 ft 0.02
rafter size 25 x 200 mm m 0.12 ft 0.04
rafter size 38 x 100 mm m 0.08 ft 0.03
rafter size 38 x 150 mm m 0.12 ft 0.04
rafter size 50 x 100 mm m 0.10 ft 0.03
rafter size 50 x 150 mm m 0.13 ft 0.04
rafter size 75 x 150 mm m 0.24 ft 0.07
joist size 50 x 175 mm nr 0.16 nr 0.16
joist size 50 x 225 mm nr 0.16 nr 0.16
18mm thick boarding; over 300mm wide m2 0.52 ft2 0.05
18mm thick boarding; n e 300mm wide m 0.21 ft 0.07
18mm thick boarding; area n e 1m2 nr 0.52 nr 0.52
12mm thick boarding; over 300mm wide m2 0.56 ft2 0.05
12mm thick boarding; n e 300mm wide m 0.21 ft 0.06
12mm thick boarding; area n e 1m2 nr 0.56 nr 0.56
18mm thick boarding; over 300mm wide m2 1.08 ft2 0.10
18mm thick boarding; n e 300mm wide m 0.44 ft 0.13
18mm thick boarding; area n e 1m2 nr 1.08 nr 1.08
12mm thick; over 300mm wide m2 0.79 ft2 0.07
12mm thick; 75mm wide m 0.14 ft 0.04
12mm thick; 150mm wide m 0.18 ft 0.06
12mm thick; 225mm wide m 0.24 ft 0.07
30 x 2.5 x 800mm girth; standard twisted vertical restraint, nr 0.11 nr 0.11
30 x 2.5 x 1000mm girth; standard twisted vertical restraint, nr 0.12 nr 0.12
30 x 2.5 x 1200mm girth; standard twisted vertical restraint, nr 0.13 nr 0.1375 x 75 x 9mm thick angle; 225mm long; standard twisted vertical restraint,
nr 0.16 nr 0.16
Roof Decking
sloping n e 50 deg; 0.70mm thick; 75mm deep corrugation m2 0.65 ft2 0.06
extra for square cutting m 0.15 ft 0.05
extra for raking cutting m 0.17 ft 0.05
m2 1.75 ft2 0.16
extra for square cutting m 0.17 ft 0.05
extra for raking cutting m 0.19 ft 0.06
Single profiled sheet construction Roof decking m2 0.35 ft2 0.03
Roof decking m2 0.60 ft2 0.06
Roof decking m2 0.50 ft2 0.05
sloping n e 50deg; 0.9mm thick; 305mm wide unit; m2 1.15 ft2 0.11
sloping n e 50deg; 1.00mm thick; 305mm wide unit; m2 1.15 ft2 0.11
sloping n e 50deg; 1.20mm thick; 305mm wide unit, m2 1.15 ft2 0.11
extra for square cutting m 0.15 ft 0.05
extra for raking cutting m 0.17 ft 0.05
sloping n e 50 deg; 60mm thick m2 0.25 ft2 0.02
sloping n e 50 deg; 80mm thick m2 0.25 ft2 0.02
sloping n e 50 deg; 100mm thick m2 0.25 ft2 0.02
sloping n e 50 deg; 150mm thick m2 0.25 ft2 0.02
extra for square cutting m 0.05 ft 0.02
extra for raking cutting m 0.06 ft 0.02
Fix standing seam aluminium roof cladding; standard natural aluminium stucco embossed finish
Lay thermal insulation quilt; roof;
ROOF DECKING AND WALL CLADDING
Fix timber; strutting
Fix timber; pitched roof
Fix plywood; roof
Norm Hrs. IMPERIAL
roof covering; 0.60mm thick outer skin 75mm deep corrugation, 80mm thick insulation; 0.40mm thick inner lining sheet
Fix galvanised steel profile composite roof decking; metallack coated finish; fixing to steel rails with plastic headed self tapping screws; 80mm thick insulation; 0.40mm thick coated inner lining sheet
Composite construction bonded together comprising profiled outer sheet, insulation, and inner lining sheet
New Work
Norm Hrs. METRIC
Sandwich construction comprising profiled outer sheet, insulation, and inner lining sheet
Fix timber; flat roof
Notch and fit timber to steel beam
Fix galvanised steel strip troughed sheet colourcoat finish; fix to steel purlins with plastic headed self tapping screws
Fix boarding; roof
Fix metal; holding down strap; timber and brickwork or blockwork
Fix plywood; eaves, verge, fascia and the like
343
sloping n e 50 deg; 0.70mm gauge m2 0.85 ft2 0.08
sloping n e 50 deg; 0.80mm gauge m2 0.85 ft2 0.08
sloping n e 50 deg; 0.90mm gauge m2 0.85 ft2 0.08
sloping n e 50 deg; 1.00mm gauge m2 0.85 ft2 0.08
extra for square cutting m 0.11 ft 0.03
extra for raking cutting m 0.12 ft 0.04
flat or to slopes n e 10 deg from horizontal; 20mm thick; m2 0.45 ft2 0.04
skirting; 13mm thick; n e 150mm girth m 0.60 ft 0.18
skirting; 13mm thick; over 150 but n e 225mm girth m 0.65 ft 0.20
skirting; 13mm thick; over 225 but n e 300mmgirth m 0.70 ft 0.21flat; over 300mm wide m2 0.75 ft2 0.07
skirting; n e 200mm girth m 0.65 ft 0.20
skirting; over 200 but n e 400mm girth m 0.70 ft 0.21
Lay PVC roofing system; single layer covering to slopes ne 10deg; over 300mm wide m2 0.25 ft2 0.02
to slopes n e 10 deg; over 300mm wide m2 0.60 ft2 0.06
1.80mm thick; 150mm girth m 0.74 ft 0.23
1.89mm thick; 240mm girth m 0.83 ft 0.25
1.80mm thick; 150mm girth m 0.83 ft 0.25
1.89mm thick; 240mm girth m 0.93 ft 0.28
Wall CladdingWall structure - timber
12mm thick wall; over 300mm wide m2 0.23 ft2 0.02
12mm thick wall; n e 300mm wide m 0.09 ft 0.03
12mm thick wall; area n e 1m2 nr 0.23 nr 0.23
18mm thick wall; over 300mm wide m2 0.29 ft2 0.03
18mm thick wall; n e 300mm wide m 0.14 ft 0.04
18mm thick wall; area n e 1m2 nr 0.29 nr 0.29
wall; bars 2.55m long at 622mm centres; 6mm thick plate glass m2 2.50 ft2 0.23
m2 2.75 ft2 0.26
aluminium framing; single glazed; 6mm clear toughened glass; m2 3.15 ft2 0.29
m2 3.25 ft2 0.30
extra for raking cutting m 0.23 ft 0.07
wall covering; 7.50mm thick; over 300mm wide m2 1.94 ft2 0.18
extra for external angle trim m 0.09 ft 0.03
extra for square cutting m 0.15 ft 0.05
extra for raking cutting m 0.16 ft 0.05
wall covering; 0.70mm thick; 75mm deep corrugation m2 0.75 ft2 0.07
extra for square cutting m 0.18 ft 0.05
extra for raking cutting m 0.19 ft 0.06
m2 1.75 ft2 0.16
extra for square cutting m 0.25 ft 0.08
extra for raking cutting m 0.26 ft 0.08
Wall cladding m2 0.30 ft2 0.03
Flashings m 0.25 ft 0.08
Square cutting m 0.15 ft 0.05
Raking cutting m 0.15 ft 0.05
Circular cutting m 0.20 ft 0.06
Wall cladding m2 0.50 ft2 0.05
Fix roof lining sheet; aluminium stucco embossed finish; fixed to steel purlins with stainless steel screws
Fit lead flashing; stepped; wedge into grooves
Fit lead flashing; wedge into grooves
wall covering; 0.60mm thick outer skin 75mm deep corrugation, 80mm thick insulation; 0.40mm thick inner lining sheet
Lay mastic asphalt; three coat work; expanded metal lathing reinforcement nailed to base
Lay built up felt roofing; three layer covering; two layers bitumen polyester based felt; two layer polyester based mineral surfaced felt; 10mm stone chipping covering, bitumen bonded.
Lay built up felt roofing; three layer; top layer mineral surfaced; dressed over tilting fillet; turned into groove
Fix plywood external quality; covering
aluminium framing; double glazed; 6mm thick clear toughened glass outer pane and 6.40mm thick laminated inner pane;
single tier; glazing bars at 850mm centres x 890mm long; overall 18mm thick; 6mm air space;
Fix aluminium curtain walling system; polyester powder coated finish; drilled and screwed to metal;
Single profiled sheet construction
Lay mastic asphalt roofing; two coat covering; felt isolating membrane; to base;
Lay flexible membrane roofing system; top layer fixing with adhesive; including insulation board and vapour barrier;
Fix window frame system; polyester powder coated finish; glazed with double hermetically sealed unit in toughened safety glass;
Fix rigid sheet cladding; flexible neoprene gasket joints; fixing with stainless sttel screws and coloured caps
Fix galvanised steel strip troughed sheet cladding; colourcoat finish; fixing to steel rails with plastic headed self tapping screws
Sandwich construction comprising profiled outer sheet, insulation, and inner lining sheet
Fix galvanised steel profile composite sheet cladding; metallack coated finish; fixing to steel rails with plastic headed self tapping screws; 80mm thick insulation; 0.40mm thick coated inner lining sheet
Fix patent glazing; aluminium alloy framing; fixed to supports.
344
Rainwater Pipework / Guttering
100mm dia down pipe; ears cast on m 0.42 ft 0.13
extra for shoe nr 0.26 nr 0.26
extra for bend nr 0.46 nr 0.46
extra for single branch nr 0.69 nr 0.69
100mm dia pipe; nr 0.19 nr 0.19
125mm dia half round gutter; to falls m 0.37 ft 0.11
extra for stop end nr 0.17 nr 0.17
extra for running outlet nr 0.32 nr 0.32
extra for stop end outlet nr 0.17 nr 0.17
100mm dia pipe; m 0.56 ft 0.17
extra for shoe nr 0.37 nr 0.37
extra for bend nr 0.60 nr 0.60
extra for single branch nr 0.74 nr 0.74
100mm dia pipe nr 0.19 nr 0.19
150mm dia half round gutter; to falls m 0.46 ft 0.14
extra for stop end nr 0.20 nr 0.20
extra for running outlet nr 0.42 nr 0.42
200 x 100mm box gutter; 3mm thick m 0.60 ft 0.18
extra for stop end nr 0.32 nr 0.32
extra for running outlet nr 0.65 nr 0.65
extra for stop end outlet nr 0.32 nr 0.32
1200mm girth boundary wall box gutter; 3mm thick; m 0.69 ft 0.21
extra for stop end nr 0.37 nr 0.37
extra for running outlet nr 0.74 nr 0.74
extra for stop end outlet nr 0.37 nr 0.37
over 500 - 1000mm girth m 2.00 ft 0.61
110mm dia pipe m 0.33 ft 0.10
extra for shoe nr 0.22 nr 0.22
extra for bend nr 0.33 nr 0.33
extra for single branch nr 0.44 nr 0.44Connect loose; to clayware drain pipe 110mm dia pipe nr 0.32 nr 0.32
170mm dia half round gutter; m 0.31 ft 0.09
extra for stop end nr 0.15 nr 0.15
extra for running outlet nr 0.29 nr 0.29
extra for stop end outlet nr 0.15 nr 0.15
50mm diameter pipes m 0.50 ft 0.15
50mm diameter pipes; in lengths n e 3.00m m 0.60 ft 0.18
Extra for rainwater shoe nr 0.60 nr 0.60
Extra for rainwater head nr 0.90 nr 0.90
Extra for connect to existing nr 0.90 nr 0.90
100mm Diameter, half round, m 0.50 ft 0.15
100mm Diameter, half round, in lengths n e 3.00m m 0.60 ft 0.18
Extra for stop end nr 0.50 nr 0.50
Extra for running outlet nr 0.00 nr 0.00
Extra for stop end outlet nr 0.00 nr 0.00
Extra for connecting to existing nr 1.00 nr 1.00
Percentage addition;working height over 10 - 20m % 10.00 % 10.00
Percentage addition;working height over 20 - 30m % 15.00 % 15.00
Percentage addition;working height over 30 - 40m % 22.50 % 22.50
Percentage addition;working height over 40 - 50m % 27.50 % 27.50
Extra over install roof; height allowance
Fix aluminium rainwater pipe; powder coated finish; plugged and screwed to background
Fix galvanised heavy pressed steel rainwater gutter; screwed to timber
Fix cast iron rainwater pipe; nailed to masonry
Fix aluminium rainwater gutter; powder coated finish;; plugged and screwed to background
Connect cast iron downpipe to clayware; joint (cement and sand 1:2)
Fix cast iron rainwater gutter; on brackets; screwed to timber
Fix uPVC rainwater pipe; pipe or socket brackets; plugged and screwed
Fix uPVC rainwater gutter; on brackets; screwed to timber
uPVC pipe and fittings; fixed with brackets; plugged and screwed
uPVC half round gutter and fittings; fixed with brackets; plugged and screwed
Connect aluminium downpipe to clayware; joint (cement and sand 1:2)
345
Clean
Area of panes n e 1.00m2 in area; n.e 2m above ground level m2 0.01 ft2 0.00
Area of panes n e 1.00m2 ; over 2.00 but n.e 5.00m above ground level
m2 0.01 ft2 0.00
Area of panes n e 1.00m2; over 5.00 but ne 10.00m above ground level
m2 0.01 ft2 0.00
Area of panes over 1.00 but ne 5.00m2; n.e. 2.00m above ground level
m2 0.01 ft2 0.00
Area of panes over 1.00 but ne 5.00m2; over 2.00m but n e 5.00m above ground level
m2 0.01 ft2 0.00
Area of panes over 1.00 but ne 5.00m2; over 5.00m but n e 10.00m above ground level
m2 0.01 ft2 0.00
Area of panes over 5.00 but n e 10.00m2; n.e 2m above ground level m2 0.01 ft2 0.00
Area of panes over 5.00 but n e 10.00m2 ; over 2.00 but n.e 5.00m above ground level
m2 0.01 ft2 0.00
Area of panes over 5.00 but n e 10.00m2; over 5.00 but ne 10.00m above ground level
m2 0.01 ft2 0.00
Area of panes n e 1.00m2 in area; n.e 2m above floor level m2 0.01 ft2 0.00
Area of panes n e 1.00m2 ; over 2.00 but n.e 5.00m above floor level m2 0.01 ft2 0.00
Area of panes n e 1.00m2; over 5.00 but ne 10.00m above floor level m2 0.01 ft2 0.00
Area of panes over 1.00 but ne 5.00m2; n.e. 2.00m above floor level m2 0.01 ft2 0.00
Area of panes over 1.00 but ne 5.00m2; over 2.00m but n e 5.00m above floor level
m2 0.01 ft2 0.00
Area of panes over 1.00 but ne 5.00m2; over 5.00 but n e 10.00m above floor level
m2 0.01 ft2 0.00
Area of panes over 5.00 but n e 10.00m2; n.e 2m above floor level m2 0.01 ft2 0.00
Area of panes over 5.00 but n e 10.00m2 ; over 2.00 but n.e 5.00m above floor level
m2 0.01 ft2 0.00
Area of panes over 5.00 but n e 10.00m2; over 5.00 but ne 10.00m above floor level
m2 0.01 ft2 0.00
Remove blockage from aluminium down pipe and flush with water
100mm dia rainwater pipe; vertical m 0.02 ft 0.01
125mm dia half round; over 2.00m but n e 5.00m above ground level m 0.03 ft 0.01
125mm dia half round; over 5.00m but n e 10.00m above ground level m 0.03 ft 0.01Remove blockage from cast iron down pipe and flush with water
100mm dia rainwater pipe; vertical m 0.02 ft 0.01
150mm dia half round; over 2.00m but n e 5.00m above ground level m 0.03 ft 0.01
150mm dia half round; over 5.00m but n e 10.00m above ground level m 0.03 ft 0.01
200m x 100mm box gutter; over 2.00 but n e 5.00m above ground level
m 0.03 ft 0.01
200m x 100mm box gutter; over 5.00 but n e 10.00m above ground level
m 0.03 ft 0.01
1200mm girth boundary wall box gutter; over 2.00 but n e 5.00m above ground level
m 0.03 ft 0.01
1200mm girth boundary wall box gutter; over 5.00 but n e 10.00m above ground level
m 0.03 ft 0.01
110mm dia rainwater pipe, vertical m 0.02 ft 0.01
170mm dia half round; over 2.00 but n e 5.00m above ground level m 0.03 ft 0.01
170mm dia half round; over 5.00 but n e 10.00m above ground level m 0.03 ft 0.01
Clean glass; externally; surfaces of glazing
Clean glass; internally; surfaces of glazing
Clean out; aluminium gutter; remove blockage; build up of silt; flush with water
Clean out; galvanised heavy pressed steel box gutters; remove blockage; build up of silt; flush with water
Clean out; cast iron gutters; remove blockage; build up of silt; flush with water
Remove blockage from uPVC down pipe and flush with waterClean out; uPVC gutter; remove blockages; build up of silt; flush with water
346
Repair
galvanised steel strip toughened sheets; 75mm corrugation; area of damage n e 0.50m2
Nr 1.50 nr 1.50
standing seam aluminium; area of damage n e 0.50m2 Nr 1.50 nr 1.50
mastic asphalt; area of damage n e 0.50m2 Nr 1.00 nr 1.00
built up felt roofing, flat; area of damage n e 0.50m2 Nr 1.00 nr 1.00
single layer plastic, area of damage n e 0.50m2 Nr 0.75 nr 0.75
flexible membrane, area of damage n e 0.50m2 nr 0.75 nr 0.75
rigid cladding sheet; damage n e 0.50m2 nr 1.50 nr 1.50
galvanised steel strip troughed sheets; damage n e 0.50m2 nr 1.50 nr 1.50
galvanised composite cladding; damage n e 0.50m2 nr 2.50 nr 2.50
Repair glazing - See Replacement
See also Doors / Windows
aluminium; 100mm dia rainwater pipe; vertical Nr 0.35 nr 0.35
cast iron; 100mm dia rainwater pipe; vertical nr 0.45 nr 0.45
uPVC; 110mm dia rainwater pipe, vertical nr 0.25 nr 0.25
aluminium gutter; 125mm dia half round; over 2.00 but n e 5.00m above ground level
nr 0.35 nr 0.35
aluminium gutter; 125mm dia half round; over 5.00 but n e 10.00m above ground level
nr 0.35 nr 0.35
cast iron gutter; 150mm dia half round; over 2.00 but n e 5.00m above ground floor level
nr 0.45 nr 0.45
cast iron gutter; 150mm dia half round; over 2.00 but n e 5.00m above ground floor level
nr 0.45 nr 0.45
galvanised heavy pressed steel gutter; 200m x 100mm box gutter; over 2.00 but n e 5.00m above ground level
nr 0.60 nr 0.60
galvanised heavy pressed steel gutter; 200m x 100mm box gutter; over 5.00 but n e 10.00m above ground level
nr 0.60 nr 0.60
galvanised heavy pressed steel gutter; 457mm boundary wall box gutter; (1200mm girth) over 2.00m but not exceeding 5.00m above ground level
nr 0.60 nr 0.60
galvanised heavy pressed steel gutter; 1200mm girth boundary wall box gutter; over 5.00 but n e 10.00m above ground level
nr 0.60 nr 0.60
uPVC guttter; 170mm dia half round; over 2.00 but n e 5.00m above ground level
nr 0.35 nr 0.35
uPVC gutter; 170mm dia half round; over 5.00 but n e 10.00m above ground level
nr 0.35 nr 0.35
Roof decking system m2 0.50 ft2 0.05
Wall cladding system m2 0.50 ft2 0.05
flashings m 0.20 ft 0.06
Percentage addition;working height over 10 - 20m % 10.00 % 10.00
Percentage addition;working height over 20 - 30m % 15.00 % 15.00
Percentage addition;working height over 30 - 40m % 22.50 % 22.50
Percentage addition;working height over 40 - 50m % 27.50 % 27.50
Carefully dismantle; set aside, protect and store; refix with new fixings; n e 10m height
Repair roof covering; with approved material,
Repair wall cladding with approved material,
Repair joint in rainwater system; reseal
Extra over Height allowance
347
Replace
6mm thick plate glass; in single panes panes n e 1.00m2 Nr 0.30 nr 0.30
6mm thick plate glass, in single panes panes over 1.00 but ne 2.25m2 Nr 0.30 nr 0.30
6mm thick plate glass; in single panes panes over 2.25m2 Nr 0.30 nr 0.30
6mm thick toughened safety glass; in single panes panes n e 1.00m2 Nr 0.30 nr 0.30
6mm thick toughened safety glass, in single panes panes over 1.00 but n e 2.25m2
Nr 0.30 nr 0.30
6mm thick toughened safety glass; in single panes panes over 2.25m2
Nr 0.30 nr 0.30
7m thick georgian wired safety glass; in single panes n e 1.00m2 nr 0.30 nr 0.30
7m thick georgian wired safety glass; in single panes over 1.00 but n e 2.25m2
nr 0.30 nr 0.30
7m thick georgian wired safety glass; in single panes over 2.25m2 nr 0.30 nr 0.30
18mm thick hermetically sealed double glazed units not exceeding 1.00m2
Nr 0.45 nr 0.45
18mm thick hermetically sealed double glazed units over 1.00 but n e 2.25m2
nr 0.45 nr 0.45
18mm thick hermetically sealed double glazed units over 2.25m2 nr 0.45 nr 0.45
patent glazing; aluminium alloy bars 2.55 m long at 622mm centres; fixed to supports
m2 0.30 ft2 0.03
window frame system; single tier; aluminium glazing bars at 850mm centres x 890mm long; timber supports
m2 0.30 ft2 0.03
curtain walling; aluminium system; m2 0.30 ft2 0.03
rigid cladded sheet; m2 0.30 ft2 0.03
Roof decking m2 0.25 ft2 0.02
Wall cladding m2 0.25 ft2 0.02
Flashing m 0.10 ft 0.03galvanised steel strip toughened sheets; 75mm corrugations; m2 0.30 ft2 0.03
standing seam aluminium; m2 0.30 ft2 0.03
mastic asphalt; m2 0.30 ft2 0.03
built up felt roofing, m2 0.30 ft2 0.03
single layer plastic, m2 0.30 ft2 0.03
flexible membrane, m2 0.30 ft2 0.03
aluminium; 100mm diameter rainwater pipe; vertical m 0.15 ft 0.05
cast iron; 100mm diameter rainwater pipe; vertical m 0.15 ft 0.05
uPVC; 110mm diameter rainwater pipe, vertical m 0.15 ft 0.05
aluminium gutter; 125mm dia half round; over 2.00 but n e 5.00m above ground level
m 0.25 ft 0.08
aluminium gutter; 125mm dia half round; over 5.00 but n e 10.00m above ground level
m 0.25 ft 0.08
cast iron gutter; 150mm dia half round; over 2.00 but n e 5.00m above ground floor level
m 0.30 ft 0.09
cast iron gutter; 150mm dia half round; over 2.00 but n e 5.00m above ground floor level
m 0.30 ft 0.09
galvanised heavy pressed steel gutter; 200 x 100mm box gutter; over 2.00 but n e 5.00m above ground level
m 0.35 ft 0.11
galvanised heavy pressed steel gutter; 200 x 100mm box gutter; over 5.00 but n e 10.00m above ground level
m 0.35 ft 0.11
galvanised heavy pressed steel gutter;1200mm girth boundary wall box gutter; over 2.00 but n e 5.00m above ground level
m 0.35 ft 0.11
galvanised heavy pressed steel gutter; 1200mm girth boundary wall box gutter; over 5.00 but n e 10.00m above ground level
m 0.35 ft 0.11
uPVC guttter; 170mm dia half round; over 2.00 but n e 5.00m above ground level
m 0.20 ft 0.06
uPVC gutter; 170mm dia half round; over 5.00 but n e 10.00m above ground level
m 0.20 ft 0.06
Percentage addition;working height over 10 - 20m % 10.00 % 10.00
Percentage addition;working height over 20 - 30m % 15.00 % 15.00
Percentage addition;working height over 30 - 40m % 22.50 % 22.50
Percentage addition;working height over 40 - 50m % 27.50 % 27.50
Carefully take down, remove and dispose
Carefully dismantle, remove and dispose; roofing system
Extra over Height allowance
Carefully dismantle; remove and dispose; make good background
Removal item only. Replacement use NEW rates
Carefully remove pane of glass and glazing system, and replace with new, to metal
Carefully dismantle, remove and dispose; wall cladding system
348
Q.2.2.3 Lining / Partitions
Structural framing
floor joist 50 x 75 mm m 0.06 ft 0.02
floor joist 50 x 150 mm m 0.09 ft 0.03
floor joist 50 x 225 mm m 0.12 ft 0.04
floor joist 75 x 150 mm m 0.13 ft 0.04
floor joist 75 x 200 mm m 0.18 ft 0.05
frame 50 x 50 mm m 0.09 ft 0.03
frame 50 x 75 mm m 0.13 ft 0.04
frame 50 x 100 mm m 0.14 ft 0.04
frame 75 x 100 mm m 0.19 ft 0.06
kerb, bearer 50 x 50 mm m 0.05 ft 0.02
kerb, bearer 38 x 75 mm m 0.06 ft 0.02
kerb, bearer 50 x 75 mm m 0.07 ft 0.02
kerb, bearer 38 x 100 mm m 0.08 ft 0.02
kerb, bearer 50 x 100 mm m 0.10 ft 0.03
kerb, bearer 75 x 150 mm m 0.24 ft 0.07
kerb, bearer 75 x 200 mm m 0.32 ft 0.10
triangular fillet 50 x 50 mm m 0.07 ft 0.02
triangular fillet 75 x 75 mm m 0.12 ft 0.04
triangular fillet 100 x 100 mm m 0.20 ft 0.06
trimmer 38 x 150 mm; form opening size 760 x 760mm Nr 0.94 Nr 0.94
trimmer 50 x 175 mm; form opening size 760 x 760 mm; Nr 1.01 Nr 1.01
trimmer 75 x 225 mm; form opening size 3000 x 1000mm Nr 3.69 Nr 3.69
softwood; 300 mm centres m 0.17 ft 0.05
softwood; 450 mm centres m 0.13 ft 0.04
softwood; 600 mm centres m 0.11 ft 0.03
softwood; 900 mm centres m 0.11 ft 0.03
softwood; n e 100mm thick; 6mm dia bolt Nr 0.14 Nr 0.14
softwood; n e 150mm thick; 6 to 13mm dia bolt Nr 0.21 Nr 0.21
softwood; n e 50mm wide m 0.05 ft 0.02
softwood; over 50 but n e 100mm wide m 0.08 ft 0.02
softwood; allowance; each additional 50mm width m 0.03 ft 0.01
softwood; n e 100mm girth m 0.08 ft 0.02
softwood; over 100 but n e 200mm girth m 0.09 ft 0.03
softwood; over 200 but n e 300mm girth m 0.11 ft 0.03
softwood; allowance; each additional 100mm girth m 0.03 ft 0.01
Linings12mm thick; over 300mm wide m2 0.51 ft2 0.05
12mm thick; n e 300mm wide m 0.18 ft 0.06
12mm thick; area n e 1.00m2 Nr 0.51 Nr 0.51
18mm thick; over 300mm wide m2 0.93 ft2 0.09
18mm thick; n e 300mm wide m 0.35 ft 0.11
18mm thick; area n e 1.00m2 Nr 0.93 Nr 0.93
18mm thick; over 300mm wide m2 0.33 ft2 0.03
18mm thick; n e 300mm wide m 0.14 ft 0.04
18mm thick; area n e 1m2 Nr 0.33 Nr 0.33
6mm thick boarding; over 300mm wide m2 0.47 ft2 0.04
6mm thick boarding; n e 300mm wide m 0.14 ft 0.04
6mm thick boarding; area n e 1m2 Nr 0.39 Nr 0.39
12mm thick boarding; over 300mm wide m2 0.59 ft2 0.05
12mm thick boarding; n e 300mm wide m 0.23 ft 0.07
12mm thick boarding; area n e 1m2 Nr 0.59 Nr 0.59
6mm thick boarding; over 300mm wide m2 0.26 ft2 0.02
6mm thick boarding; n e 300mm wide m 0.12 ft 0.04
6mm thick boarding; area n e 1m2 Nr 0.26 Nr 0.26
6mm thick boarding; n e 600mm girth m2 0.32 ft2 0.03
6mm thick boarding; over 600 but n e 1200mm girth m2 0.27 ft2 0.03
plywood; allowance; each additional 600mm girth % 0.01 % 0.01
9mm thick boarding; n e 600mm girth m2 0.38 ft2 0.04
9mm thick boarding; over 600 but n e 1200mm girth m2 0.33 ft2 0.03
plywood; allowance; each additional 600mm girth % 0.01 % 0.01
6mm thick boarding; n e 600mm girth m2 0.32 ft2 0.03
6mm thick boarding; over 600 but n e 1200mm girth m2 0.27 ft2 0.03
plywood allowance; each addition 600mm girth % 0.01 % 0.01
extra; form access panel size 600 x 600mm Nr 0.53 Nr 0.53
extra; form external angle m 0.03 ft 0.01
extra; form internal angle m 0.03 ft 0.01
extra; form hole Nr 0.02 Nr 0.02
9mm thick boarding; n e 600mm girth m2 0.38 ft2 0.04
9mm thick boarding; over 600 but n e 1200mm girth m2 0.33 ft2 0.03
plywood allowance; each addition 600mm girth % 0.01 % 0.01
extra; form access panel size 600 x 600mm Nr 0.53 Nr 0.53
extra; form external angle m 0.03 ft 0.01
extra; form internal angle m 0.03 ft 0.01
extra; form hole Nr 0.02 Nr 0.02
6mm thick boarding; n e 600mm girth m2 0.48 ft2 0.04
6mm thick boarding; over 600 but n e 1200mm girth m2 0.43 ft2 0.04
hardboard; allowance; each additional 600mm girth % %
9mm thick boarding; n e 600mm girth m2 0.68 ft2 0.06
9mm thick boarding; over 600 but n e 1200mm girth m2 0.44 ft2 0.04
hardboard; allowance; each additional 600mm girth % %
6mm thick boarding; n e 600mm girth m2 0.48 ft2 0.04
6mm thick boarding; over 600 but n e 1200mm girth m2 0.43 ft2 0.04
hardboard allowance; each addition 600mm girth % %
extra; form access panel size 600 x 600mm Nr 0.53 Nr 0.53
extra; form external angle m 0.03 ft 0.01
extra; form internal angle m 0.03 ft 0.01
extra; form hole Nr 0.02 Nr 0.02
9mm thick boarding; n e 600mm girth m2 0.49 ft2 0.05
9mm thick boarding; over 600 but n e 1200mm girth m2 0.44 ft2 0.04
hardboard allowance; each addition 600mm girth % %
extra; form access panel size 600 x 600mm Nr 0.53 Nr 0.53
extra; form external angle m 0.03 ft 0.01
extra; form internal angle m 0.03 ft 0.01
extra; form hole Nr 0.02 Nr 0.02
Fix plywood; isolated column
Fix plywood; floor
Fix plywood; wall
Fix plywood; isolated beam
LINING / PARTITIONS
Fix timber; floor
Fix timber; wall or partition
Extra; plugging and screwing; concrete, brickwork or blockwork
Norm Hrs. IMPERIAL
Norm Hrs. METRIC
Extra;for wrought face
Extra; bolting; including form holes; concrete, brickwork or blockwork
Fix hardboard; wall
New Work
Fix hardboard; isolated column
Fix hardboard; isolated beam
Fix chipboard; floor
349
lining; one layer 12.5mm board; over 2.40 but n e 2.70m high m 0.97 ft 0.30
lining; one layer 12.5mm board; over 2.70 but n e 3.00m high m 1.11 ft 0.34
lining; one layer 12.5mm board; over 3.00 but n e 3.30m high m 1.25 ft 0.38
lining; one layer 12.5mm board; over 3.30 but n e 3.60m high m 1.43 ft 0.44
ceiling; one layer 12.5mm board; over 300mm wide m2 0.41 ft2 0.04
Partition 62.5mm partition; one layer 12.5mm board; over 2.10 but n e 2.40m high m 3.05 ft 0.93
62.5mm partition; one layer 12.5mm board; over 2.40 but n e 2.70m high m 3.56 ft 1.09
62.5mm partition; one layer 12.5mm board; over 2.70 but n e 3.00m high m 3.94 ft 1.20
62.5mm partition; one layer 12.5mm board; over 3.00 but n e 3.30m high m 4.58 ft 1.40
62.5mm partition; one layer 12.5mm board; over 3.30 but n e 3.60m high m 4.95 ft 1.51
62.5mm partition; one layer 12.5mm board; over 3.60 but n e 3.90m high m 5.95 ft 1.81
62.5mm partition; one layer 12.5mm board; over 3.90 but n e 4.20m high m 6.20 ft 1.89
80mm partition; one layer 12.5mm board each side; one hour fire resistance; over 2.10 but n e 2.40m high
m 3.89 ft 1.19
80mm partition; one layer 12.5mm board each side; one hour fire resistance; over 2.40 but n e 2.70m high
m 4.49 ft 1.37
80mm partition; one layer 12.5mm board each side; one hour fire resistance; over 2.70 but n e 3.00m high
m 5.00 ft 1.53
80mm partition; one layer 12.5mm board each side; one hour fire resistance; over 3.00 but n e 3.30m high
m 5.78 ft 1.76
80mm partition; one layer 12.5mm board each side; onr hour fire resistance; over 3.30 but n e 3.60m high
m 6.34 ft 1.93
80mm partition; one layer 12.5mm board each side; one hour fire resistance; over 3.60 but n e 3.90m high
m 7.59 ft 2.31
80mm partition; one layer 12.5mm board each side; one hour fire resistance; over 3.90 but n e 4.20m high
m 8.14 ft 2.48
100mm partition; two layer 12.5mm board each side; two hour fire resistance; over 2.10 but n e 2.40m high
m 4.81 ft 1.47
100mm partition; two layer 12.5mm board each side; two hour fire resistance; over 2.40 but n e 2.70m high
m 5.53 ft 1.69
100mm partition; two layer 12.5mm board each side; two hour fire resistance; over 2.70 but n e 3.00m high
m 6.15 ft 1.88
100mm partition; two layer 12.5mm board each side; two hour fire resistance; over 3.00 but n e 3.30m high
m 6.13 ft 1.87
100mm partition; two layer 12.5mm board each side; two hour fire resistance; over 3.30 but n e 3.60m high
m 7.72 ft 2.35
100mm partition; two layer 12.5mm board each side; two hour fire resistance; over 3.60 but n e 3.90m high
m 7.59 ft 2.31
100mm partition; two layer 12.5mm board each side; two hour fire resistance; over 3.90 but n e 4.20m high
m 9.76 ft 2.98
one layer 50mm thick; half hour fire resistance; 900mm wide m 0.56 ft 0.17
two layer 50mm thick; one hour fire resistance; 900mm wide m 0.83 ft 0.25
Suspended ceilingm2 1.30 ft2 0.12
m2 0.32 ft2 0.03
over 3.50 but n e 5.00m high % 0.03 % 0.03
over 5.00 but n e 7.50m high % 0.05 % 0.05
over 7.50 but n e 10.00m high % 0.08 % 0.08
over 10.00m high % 0.10 % 0.10
Extra over fit ceiling system for working at heights above 3.50m
Fit exposed suspended ceiling system; adjustable hangers fixed to concrete or steel soffit; tegular fissured tile
Fit; gyproc laminated wall lining system; comprising metal stud frame, floor and ceiling channels; plugged and screwed to concrete; tapered edge panels; joints filled with joint filler and tape to receive direct decoration;
lay in grid; tiles 15mm thick size 600 x 600mm; over 300mm width; hangers average 400mm long
lining; one layer 12.5mm board; over 300mm width; hangers average 400mm long
Fit; gypsum plasterboard lining system; plain grade tapered edge; joints filled with joint filler and tape to receive direct decoration; to softwood
Fit suspended ceiling system; adjustable hangers fixed to concrete or steel soffit; standard size tapered edge wallboard; joints filled with joint filler and tape; finish to receive direct decoration
Fit Rockwool fire barrier; between top of suspended ceiling and concrete soffit
Fit; gyproc laminated wall lining system; comprising metal stud frame, floor and ceiling channels; plugged and screwed to concrete; tapered edge panels; joints filled with joint filler and tape to receive direct decoration;
Clean
Not applicable - See surface finishes
Repair
wall, lining or partition; area n e 0.50m2 nr 0.35 Nr 0.35
ceiling; area n e 0.50m2 nr 0.40 Nr 0.40
tile; 15mm thick size 600 x 600mm nr 0.04 Nr 0.04
Repair damaged wallboard with approved material,
Repair damaged suspended ceiling system; lay in grid ; take down existing and replace with new
350
ReplaceRemoval of linings and partitioning only. Replacement use NEW rates
12.5mm thick board; wall lining over 2.40 but n e 2.70m high m 0.24 ft 0.07
12.5mm thick board; wall lining over 2.70 but n e 3.00m high m 0.28 ft 0.08
12.5mm thick board; wall lining over 3.00 but n e 3.30m high m 0.31 ft 0.10
12.5mm thick board; wall lining over 3.30 but n e 3.60m high m 0.36 ft 0.11
62.5mm thick partition; over 2.10 but n e 2.40m high m 0.76 ft 0.23
62.5mm thick partition; over 2.40 but n e 2.70m high m 0.89 ft 0.27
62.5mm thick partition; over 2.70 but n e 3.00m high m 0.99 ft 0.30
62.5mm thick partition; over 3.00 but n e 3.30m high m 1.15 ft 0.35
62.5mm thick partition; over 3.30 but n e 3.60m high m 1.24 ft 0.38
62.5mm thick partition; over 3.60 but n e 3.90m high m 1.49 ft 0.45
62.5mm thick partition; over 3.90 but n e 4.20m high m 1.55 ft 0.47
80mm thick partition; over 2.10 but n e 2.40m high m 0.97 ft 0.30
80mm thick partition; over 2.40 but n e 2.70m high m 1.12 ft 0.34
80mm thick partition; over 2.70 but n e 3.00m high m 1.25 ft 0.38
80mm thick partition; over 3.00 but n e 3.30m high m 1.45 ft 0.44
80mm thick partition; over 3.30 but n e 3.60m high m 1.59 ft 0.48
80mm thick partition; over 3.60 but n e 3.90m high m 1.90 ft 0.58
80mm thick partition; over 3.90 but n e 4.20m high m 2.04 ft 0.62
100mm thick partition; over 2.10 but n e 2.40m high m 1.20 ft 0.37
100mm thick partition; over 2.40 but n e 2.70m high m 1.38 ft 0.42
100mm thick partition; over 2.70 but n e 3.00m high m 1.54 ft 0.47
100mm thick partition; over 3.00 but n e 3.30m high m 1.53 ft 0.47
100mm thick partition; over 3.30 but n e 3.60m high m 1.93 ft 0.59
100mm thick partition; over 3.60 but n e 3.90m high m 1.90 ft 0.58
100mm thick partition; over 3.90 but n e 4.20m high m 2.44 ft 0.74
one layer 50mm thick; 900mm wide m 0.15 ft 0.05
two layer 50mm thick; 900mm wide m 0.15 ft 0.05Carefully take down; remove and dispose of suspended ceiling system m2 0.15 ft2 0.01
m2 0.15 ft2 0.01
over 3.50 but n e 5.00m high % 0.03 % 0.03
over 5.00 but n e 7.50m high % 0.05 % 0.05
over 7.50 but n e 10.00m high % 0.08 % 0.08
over 10.00m high % 0.10 % 0.10
Carefully take down; remove and dispose of gypsum lining system; fixed to softwood
Carefully take down , remove and dispose of gyproc partitioning system; making good background
Extra over take down ceiling system for working at heights above 3.50m
lining; one layer 12.5mm board; over 300mm width; hangers average 400mm long
lay in grid; tiles 15mm thick size 600 x 600mm; over 300mm width; hangers average 400mm long
Carefully take down; remove and dispose of Rockwool fire barrier;
351
Q.2.2.4 Doors & Windows
Door Frame Liningsize 50 x 50mm; jamb, head, sill, mullion and transom m 0.23 ft 0.07
size 50 x 75mm; jamb, head, sill, mullion and transom m 0.24 ft 0.07
size 50 x 100mm; jamb, head, sill, mullion and transom m 0.29 ft 0.09
size 50 x 125mm; jamb, head, sill, mullion and transom m 0.31 ft 0.09
size 75x 75mm; jamb, head, sill, mullion and transom m 0.28 ft 0.09
size 75x 100mm; jamb, head, sill, mullion and transom m 0.33 ft 0.10
450mm centres m 0.16 ft 0.05
Percentage adjustment % 0.05 % 0.05
n e 75mm wide m 0.15 ft 0.05
over 75 but n e 150mm wide m 0.15 ft 0.05
450mm centres m 0.16 ft 0.05
Door - External Quality44mm thick; size 807 x 2000mm nr 2.02 nr 2.02
44mm thick; size 907 x 2000mm Nr 2.02 nr 2.02
extra for rebated meeting style m ft
extra for rounded heel m ft
54mm thick; size 726 x 2040mm; one hour fire resistant nr 1.71 nr 1.71
54mm thick; size 826 x 2040mm; one hour fire resistant nr 1.71 nr 1.71
nr 5.00 nr 5.00
nr 7.50 nr 7.50
structural opening size 900 x 2100mm nr 4.50 nr 4.50
structural opening size 1800 x 2100mm nr 7.00 nr 7.00
size 1000 x 2750mm nr 6.25 nr 6.25
size 1500 x 2750mm nr 6.75 nr 6.75
size 2400 x 2750mm nr 8.00 nr 8.00
Door - Internal Quality44mm thick; size 762 x 1981mm nr 1.30 nr 1.30
44mm thick; size 826 x 1981mm nr 1.41 nr 1.41
extra for rebated meeting style m ft
extra for rounded heel m ft
54mm thick; size 726 x 2040mm; one hour fire resistant nr 1.71 nr 1.71
54mm thick; size 826 x 2040mm; one hour fire resistant nr 1.71 nr 1.71
Window
See also wall cladding
size 900 x 600mm nr 0.83 nr 0.83
size 900 x 900mm nr 1.02 nr 1.02
size 1200 x 900mm nr 1.11 nr 1.11
size 1200 x 1200mm nr 1.34 nr 1.34
size 1200 x 1500mm nr 1.57 nr 1.57
size 900 x 600mm nr 0.83 nr 0.83
size 900 x 900mm nr 1.02 nr 1.02
size 1200 x 900mm nr 1.11 nr 1.11
size 1200 x 1200mm nr 1.34 nr 1.34
size 1200 x 1500mm nr 1.57 nr 1.57
size 630 x 925mm nr 1.11 nr 1.11
size 630 x 1515mm nr 1.11 nr 1.11
size 1240 x 925mm nr 1.62 nr 1.62
size 1240 x 1220mm nr 1.62 nr 1.62
size 1240 x 1515mm nr 1.62 nr 1.62
size 900 x 600mm nr 1.76 nr 1.76
size 900 x 900mm nr 1.90 nr 1.90
size 900 x 1200mm nr 2.04 nr 2.04
size 1200 x 1200mm nr 2.17 nr 2.17
size 1200 x 1800mm nr 2.31 nr 2.31
Fit window, softwood frame, side hung casement; hung on pair of hinges, (glazing and other ironmongery measured separately)
Fit door; semi solid flush plywood faced; hung on pair of butt hinges; (other ironmongery measured separately)
New Work
1.01
Fit door; semi solid flush plywood faced; hung on pair and a half of butt hinges; (other ironmongery measured separately)
25mm thick tongued and grooved "V" jointed boarding; 25 x 150mm ledge and brace; size 726 x 1981mm
Fit door frame and lining set; softwood
nr
Norm Hrs. IMPERIAL
1.01
Norm Hrs. METRICDOORS AND WINDOWS
Fit window; factory finished steel fixed light; polyester powder coated; fixed in position plugged and screwed to brickwork or blockwork; (glazing measured separately)
nr
Extra over fit door frame irrespective of size; plug and screw
Extra over fit door frame irrespective of size; hardwood; pelleted
Extra over fit door frame irrespective of size; hardwood; screwed
Extra over fit door frame irrespective of size; hardwood; pelleted
46mm thick; structural opening size 980 x 2100mm; single door set; panic bolt
Fit doorset; door and frame unit; insulated door plywood faced polyester coated laminated finish; hardwood lipping all edges; sheet steel bonded into core; hardwood frame; fixing with frame anchors; weather strip all round; cutting mortices
46mm thick; structural opening size 1800 x 2100mm; single door set; panic bolt
Extra over fit door frame irrespective of size; hardwood; plug and srcew
Fit rolling shutter doorset; galvanised steel; self coiling; activation by fusible link; fixing with bolts
Fit door; wrot softwood framed ledged and braced; hung on pair of butt hinges ( other ironmongery measured separately)
Fit doorset; steel door and frame unit; single action door set; polyester powder coated finish; including fitting all ironmongery
Fit door; semi solid flush plywood faced; hung on pair and a half of butt hinges; (other ironmongery measured separately)
Fit door; semi solid flush plywood faced; hung on pair of butt hinges; (other ironmongery measured separately)
Fit rooflight; galvanised steel; plugged and screwed to concrete; or screwed to timber; fixed light complete unit
Fit window, softwood frame, top hung casement; hung on pair of hinges, (glazing and other ironmongery measured separately)
352
Glass6mm thick float glass; panes n e 0.15m2 m2 0.02 ft2 0.00
6mm thick float glass; panes oveer 0.15 but n e 4.00m2 m2 0.02 ft2 0.00
6mm thick float glass; panes n e 0.15m2 m2 0.17 ft2 0.02
6mm thick float glass; panes oveer 0.15 but n e 4.00m2 m2 0.16 ft2 0.01
6mm thick georgian wired rough cast glass; panes n e 0.15m2 m2 1.74 ft2 0.16
m2 1.60 ft2 0.15
6mm thick georgian wired polished glass; panes n e 0.15m2 m2 1.76 ft2 0.16
m2 1.67 ft2 0.16
6mm thick georgian wired rough cast glass; panes n e 0.15m2 m2 1.86 ft2 0.17
m2 1.72 ft2 0.16
7.9mm thick laminated glass; in panes n e 0.15m2 m2 1.06 ft2 0.10
7.9mm thick laminated glass; in panesover 0.15 but n e 4.00m2 m2 0.82 ft2 0.08
double glazing unt; 5.9mm thick laminated glass; 6mm thick air space float; in panes n e 0.15m2
m2 3.44 ft2 0.32
double glazing unt; 5.9mm thick laminated glass; 6mm thick air space float; in panes over 0.15 but n e 4.00m2
m2 3.28 ft2 0.31
panes n e 0.15m2 m2 0.78 ft2 0.07
panes over 0.15 but n e 4.00m2 m2 0.69 ft2 0.06
panes n e 0.15m2 m2 0.78 ft2 0.07
panes over 0.15 but n e 4.00m2 m2 0.69 ft2 0.06
Ironmongery; butt hinge (pair) nr 0.23 nr 0.23
casement stay and hasp nr 0.16 nr 0.16
door closer; light duty surface fixed nr 0.93 nr 0.93
kicking plate nr 0.23 nr 0.23
latch; cylinder rim night latch nr 0.69 nr 0.69
lock, upright mortice nr 0.77 nr 0.77
lock; dead lock nr 0.39 nr 0.39
pull handle; back fixed nr 0.16 nr 0.16
push plate nr 0.16 nr 0.16
butt hinge (pair) nr 0.32 nr 0.32
casement stay and hasp nr 0.21 nr 0.21
door closer; light duty surface fixed nr 1.20 nr 1.20
kicking plate nr 0.42 nr 0.42
latch; cylinder rim night latch nr 0.93 nr 0.93
lock, upright mortice nr 1.03 nr 1.03
lock; dead lock nr 0.52 nr 0.52
pull handle; back fixed nr 0.21 nr 0.21
push plate nr 0.21 nr 0.21
butt hinge (pair) nr 0.32 nr 0.32
casement stay and hasp nr 0.21 nr 0.21
door closer; light duty surface fixed nr 1.20 nr 1.20
kicking plate nr 0.42 nr 0.42
latch; cylinder rim night latch nr 0.93 nr 0.93
lock, upright mortice nr 1.03 nr 1.03
lock; dead lock nr 0.52 nr 0.52
pull handle; back fixed nr 0.21 nr 0.21
push plate nr 0.21 nr 0.21
Fit to door or window; metal
Fit to door or window; hardwood
Fit to door or window; softwood
6mm thick georgian wired rough cast glass; panes over 0.15 but n e 4.00m2
6mm thick georgian wired rough cast glass; panes over 0.15 but n e 4.00m2
Fit glazing; metal with metal casement putty and clip on beads
Fit glazing; wood with screwed beads and butyl compound
Fit glazing; metal with setting blocks, silicone butyl glazing mastic and pressed steel beads
Apply; shatterproof film; surface of glass
6mm thick georgian wired polished glass; panes over 0.15 but n e 4.00m2
Fit glazing; wood with putty
Apply; solar reflective film; surface of glass
Clean
For cleaning glass - See Roof decking
353
Repair
44mm thick door; size 807 x 2000mm nr 0.75 nr 0.75
44mm thick door; size 907 x 2000mm nr 0.75 nr 0.75
54mm thick door; size 726 x 2040mm nr 0.75 nr 0.75
54mm thick door; size 826 x 2040mm nr 0.75 nr 0.75
doorset; structural opening size 900 x 2100 nr 3.75 nr 3.75
doorset; structural opening size 1800 x 2100 nr 5.25 nr 5.25
irrespective of opening size nr 1.25 nr 1.25
44mm thick door; size 807 x 2000 nr 0.75 nr 0.75
44mm thick door; size 907 x 2000 nr 0.75 nr 0.75
54mm thick door; size 726 x 1981 nr 0.75 nr 0.75
54mm thick door; size 826 x 1981 nr 0.75 nr 0.75
900 x 600mm nr 0.35 nr 0.35
1200 x 600mm nr 0.35 nr 0.35
1500 x 600mm nr 0.35 nr 0.35
general surface; over 300mm girth m2 0.74 ft2 0.07
general surface; n e 300mm girth m2 0.33 ft2 0.03
general surface; n e 0.50m2 nr 0.56 nr 0.56
window; panes over 0.15m2 m2 0.94 ft2 0.09
window; panes n e 0.15m2 m2 1.09 ft2 0.10
general surface; over 300mm girth m2 0.91 ft2 0.08
general surface; n e 300mm girth m2 0.42 ft2 0.04
general surface; n e 0.50m2 nr 0.68 nr 0.68
window; panes over 0.15m2 m2 1.18 ft2 0.11
window; panes n e 0.15m2 m2 1.35 ft2 0.13
Carefully take off internal quality door from frame; remove support hinges; realign door edge and hinges refix to frame; rehang door; make good finish
Carefully take off external quality door from frame; set aside door; remove support hinges; realign door edge and hinges refix to frame; rehang door; make good finish
Strip with chemical agent, rub down to remove existing painting system; metal, or wood surface
Carefully take off opening light from window; set aside casement; remove support hinges; realign casement edge and hinges; rehang casement; make good
Carefully dismantle fusible link from rolling shutter doorset; repair and reinstall
Carefully take off steel security door; dismantle counterweight system; remove and set aside door; realign and reinstall counterweight system; rehang door
Removal of existing paint system only. Replacement (repainting) use New Painting rates Surface Finishe s
Burn off, rub down to remove existing painting system; metal, or wood surface
Replace
6mm thick sheet or plate glass; glazed with putty m 0.11 ft 0.03
6mm thick sheet or plate glass; glazed with screwed beads m 0.23 ft 0.07
6mm thick sheet or plate glass; glazed with metal casement putty m 0.11 ft 0.03
6mm thick sheet or plate glass; glazed with clip on beads m 0.14 ft 0.04
6mm thick wired or toughened glass; glazed with putty m 0.14 ft 0.04
6mm thick wired or toughened glass; glazed with screwed beads m 0.28 ft 0.09
6mm thick wired or toughened glass; glazed with putty m 0.14 ft 0.04
6mm thick wired or toughened glass; glazed with screwed beads m 0.17 ft 0.05
unit; single door nr 0.69 nr 0.69
unit; double (pair) nr 1.15 nr 1.15
door; single nr 0.92 nr 0.92
door; double (pair) nr 1.37 nr 1.37
door; single nr 0.92 nr 0.92
door; double (pair) nr 1.37 nr 1.37
size 1000 x 2750mm nr 1.15 nr 1.15
size 1500 x 2750mm nr 1.35 nr 1.35
size 2400 x 2750mm nr 1.65 nr 1.65
size 900 x 600mm nr 0.25 nr 0.25
size 900 x 900mm nr 0.25 nr 0.25
size 1200 x 900mm nr 0.35 nr 0.35
size 1200 x 1200mm nr 0.35 nr 0.35
size 1200 x 1500mm nr 0.40 nr 0.40
size 630 x 925mm nr 0.25 nr 0.25
size 630 x 1515mm nr 0.35 nr 0.35
size 1240 x 925mm nr 0.35 nr 0.35
size 1240 x 1220mm nr 0.35 nr 0.35
size 1240 x 1515mm nr 0.40 nr 0.40
size 900 x 600mm nr 0.25 nr 0.25
size 900 x 900mm nr 0.25 nr 0.25
size 900 x 1200mm nr 0.35 nr 0.35
size 1200 x 1200mm nr 0.35 nr 0.35
size 1200 x 1800mm nr 0.42 nr 0.42
butt hinge (pair) nr 0.06 nr 0.06
casement stay and hasp nr 0.04 nr 0.04
door closer; light duty surface fixed nr 0.23 nr 0.23
kicking plate nr 0.06 nr 0.06
latch; cylinder rim night latch nr 0.17 nr 0.17
lock, upright mortice nr 0.19 nr 0.19
lock; dead lock nr 0.10 nr 0.10
pull handle; back fixed nr 0.04 nr 0.04
push plate nr 0.04 nr 0.04
Dismantle window complete with glazing; factory finished steel fixed light; remove to agreed location on site; make good opening exposed
Dismantle rooflight; galvanised steel; fixed light complete unit; remove to agreed location on site; make good opening exposed
Carefully dismantle; remove and dispose of ironmongery from timber or metal; filling in exposed fixing holes
Dismantle window complete with glazing, timber casement; remove to agreed location on site; make good opening exposed
Carefully remove existing glass and glazing; hack out and prepare wood rebate; irrespective size of pane
Carefully remove existing glass and glazing; hack out and prepare; metal rebate; irrespective size of pane
Carefully remove existing glass and glazing; hack out and prepare wood rebate; irrespective size of pane
Carefully remove existing glass and glazing; hack out and prepare; metal rebate; irrespective size of pane
Dismantle external door, metal frame complete; remove to agreed location on site; make good opening exposed
Removal of existing glass and glazing only. Replace ment (reglazing) use New Doors / Windows rates
Removal and preparation only, for replacement use N EW rates
Dismantle rolling shutter doorset; remove to agreed location on site; make good opening exposed
Dismantle external door; from timber ; remove to agreed location on site; make good frame
Dismantle internal door, timber frame and architraves complete; remove to agreed location on site; make good opening exposed
354
Q.2.2.5 Surface Finishes
Floor Preparationfloor; 3mm thick; one coat; level or to falls; over 300 mm wide; m2 0.09 ft2 0.01floor; 3mm thick; one coat; to falls and crossfalls; over 300mm wide; m2 0.09 ft2 0.01
floor; 3mm thick; one coat; slopes over 15 deg; over 300 mm wide; m2 0.16 ft2 0.02
floor; 3mm thick; one coat; level or to falls; n e 300mm wide; m 0.22 ft 0.07
floor; 3mm thick; one coat; to falls and crossfalls; n e 300mm wide; m 0.22 ft 0.07
floor; 3mm thick; one coat; to slopes over 15 deg; n e 300mm wide; m 0.22 ft 0.07
floor; 3mm thick; one coat; level or to falls; over 300 mm wide; m2 0.14 ft2 0.01
floor; 3mm thick; one coat; to falls and crossfalls; over 300mm wide; m2 0.14 ft2 0.01
floor; 3mm thick; one coat; slopes over 15 deg; over 300 mm wide; m2 0.14 ft2 0.01
floor; 3mm thick; one coat; level or to falls; n e 300mm wide; m2 0.19 ft2 0.02
floor; 3mm thick; one coat; to falls and crossfalls; n e 300mm wide; m2 0.19 ft2 0.02
floor; 3mm thick; one coat; to slopes over 15 deg; n e 300mm wide; m2 0.19 ft2 0.02
floor 50mm thick; level or to falls; over 300mm wide m2 0.32 ft2 0.03floor 50mm thick; to falls and crossfalls; over 300mm wide m2 0.33 ft2 0.03floor 50mm thick; to slopes over 15 deg; over 300mm wide m2 0.34 ft2 0.03extra for floated finish; irrespective of surface gradient m2 0.01 ft2 0.00extra for trowelled finish; irrespective of surface gradient m2 0.01 ft2 0.00extra; single layer wrapping fabric reinforcement m2 0.09 ft2 0.01
50mm thick; level or to falls; over 300mm wide m2 0.18 ft2 0.02
50mm thick; to falls and crossfalls; over 300mm wide m2 0.35 ft2 0.03
50mm thick; to slopes over 15 deg; over 300mm wide m2 0.36 ft2 0.03
extra sprinkling carborundum grit on surface; trowelled in m2 0.12 ft2 0.01
extra treating surface with hardener m2 0.06 ft2 0.01
percentage adjustment working in staircase area % 0.03 % 0.03
percentage adjustment working in plant room % 0.03 % 0.03
Fix ; brass; run into concrete dividing strip 10 x 3mm wide; including anchoring with wire; m 0.39 ft 0.12
nosing 60 x 32mm m 0.48 ft 0.15
nosing 92 x 32mm m 0.67 ft 0.20
Wall preparation12mm thick; wall; over 300mm wide m2 0.26 ft2 0.02
12mm thick; wall; n e 300mm wide m 0.11 ft 0.03
extra for floated finish m2 0.01 ft2 0.00
extra for trowelled finish m2 0.01 ft2 0.00
3mm thick; 9mm thick lining; wall; over 300mm wide; screwed to metal m2 0.36 ft2 0.03
3mm thick; 9mm thick lining; wall; n e 300 wide; screwed to metal m 0.22 ft 0.07
3mm thick; 9mm thick lining; isolated column; over 300mm wide m2 0.36 ft2 0.03
3mm thick; 9mm thick lining; isolated column; n e 300mm wide m 0.22 ft 0.07
3mm thick; 9mm thick lining; over 300mm wide; m2 0.12 ft2 0.01
3mm thick; 9mm thick lining; n e 300mm wide; m 0.08 ft 0.02
13mm thick; wall; over 300mm wide m2 0.22 ft2 0.02
13mm thick; wall; n e 300mm wide m 0.10 ft 0.03
13mm thick; isolated column; over 300mm wide m2 0.28 ft2 0.03
13mm thick; isolated column; n e 300mm wide m 0.15 ft 0.05
13mm thick; over 300mm wide; m2 0.12 ft2 0.01
13mm thick; n e 300mm wide; m 0.08 ft 0.02
percentage adjustment working in staircase area % 0.03 % 0.03
percentage adjustment working in plant room % 0.03 % 0.03
Ceiling preparation3mm thick; 9mm thick baseboard; ceiling over 300mm wide; screwed to metal
m2 0.43 ft2 0.04
3mm thick; 9mm thick baseboard; ceiling n e 300mm wide; screwed to metal
m 0.06 ft 0.02
3mm thick; 9mm thick baseboard; isolated beam; over 300 wide; screwed to metal
m2 0.36 ft2 0.03
3mm thick; 9mm thick baseboard; isolated beam; n e 300 wide; screwed to metal
m 0.22 ft 0.07
13mm thick; ceiling; over 300mm wide m2 0.26 ft2 0.02
13mm thick; ceiling; n e 300mm wide m 0.12 ft 0.04
13mm thick; isolated beam; over 300mm wide m2 0.31 ft2 0.03
13mm thick; isolated beam n e 300mm wide m 0.15 ft 0.05
13mm thick; over 300mm wide; m2 0.40 ft2 0.04
13mm thick; n e 300mm wide; m2 0.06 ft2 0.01
percentage adjustment working in staircase area % 0.03 % 0.03
percentage adjustment working in plant room % 0.03 % 0.03
percentage adjustment; over 3.5m high % 0.04 % 0.04
angle bead; brickwork or blockwork m 0.03 ft 0.01
angle bead; concrete m 0.04 ft 0.01
stop bead; brickwork or blockwork m 0.04 ft 0.01
stop bead; concrete m 0.04 ft 0.01
architrave bead; brickwork or blockwork m 0.05 ft 0.02
architrave bead; concrete m 0.05 ft 0.02
Extra over ceiling preparation forFix plaster accessories;
Lay granolithic paving; cement and granite chippings; on concrete laid whilst green; trowelled finish
Norm Hrs. IMPERIAL
Extra over floor preparation for
Apply cement and sand (1:3); render; to concrete, brickwork or blockwork
Apply plaster; one coat work; finishing coat; including fix baseboard; steel trowelled finish
Norm Hrs. METRIC
New Work
Lay cement and sand (1:3); screed; on concrete
Lay latex based levelling compound;
Lay acrylic based levelling compound;
Fix ; aluminium alloy; plugged and screwed; concrete
SURFACE FINISHES
Extra; fixed to softwood
Apply plaster; two coat work; bonding and finishing coat; prepared background; steel trowelled finish
Extra; fixed to metal lathing
Extra over wall preparation for
Apply plaster; one coat work; finishing coat; including baseboard; steel trowelled finish
Apply plaster; two coat work; bonding and finishing coat; prepared background; steel trowelled finish
Extra; fixed to metal lathing
355
0.30mm thick; 10mm mesh; over 300mm wide; softwood m2 0.32 ft2 0.03
0.30mm thick; 10mm mesh; n e 300mm wide; softwood m 0.13 ft 0.04
0.30mm thick; 10mm mesh; over 300mm wide; concrete, brickwork or blockwork
m2 0.43 ft2 0.04
0.30mm thick; 10mm mesh; n e 300mm wide; concrete, brickwork or blockwork
m 0.18 ft 0.05
0.30mm thick; 10mm mesh; over 300mm wide; wired to steelwork m2 0.41 ft2 0.04
0.30mm thick; 10mm mesh; n e 300mm wide; wired to steelwork m 0.21 ft 0.06
Floor finish
See also painting section12mm thick; floor; level or to falls; over 300mm wide m2 1.07 ft2 0.10
12mm thick; floor; falls and to crossfalls; over 300mm wide m2 1.09 ft2 0.10
12mm thick; floor; to slopes over 15 deg; over 300mm wide m2 1.12 ft2 0.10
extra for square cutting m 0.60 ft 0.18
extra for raking cutting m 0.60 ft 0.18
12mm thick; tread; n e 300mm wide; m 0.39 ft 0.12
12mm thick; plain riser; n e 300mm wide; m 0.42 ft 0.13
12mm thick; coved skirting; 150mm high; m 0.30 ft 0.09
extra over 12mm thick tile; bullnosed edge m 0.05 ft 0.02
extra over 12mm thick tile; fair edge Nr 0.05 Nr 0.05
extra over 12mm thick tile; internal angle Nr 0.11 Nr 0.11
extra over 12mm thick tile; external angle Nr 0.11 Nr 0.11
3mm thick; floor; over 300mm wide; level or to falls; m2 0.23 ft2 0.02
3mm thick; floor; over 300mm wide; to slopes n e 15 deg; m2 0.23 ft2 0.02
3mm thick; floor; n e 300mm wide; level or to falls m 0.31 ft 0.10
3mm thick; floor; n e 300mm wide; to slopes n e 15 deg m 0.31 ft 0.10
extra for square cutting m 0.24 ft 0.07
extra for raking cutting m 0.24 ft 0.07
2mm thick; floor; over 300mm wide; level or to falls; m2 0.33 ft2 0.03
2mm thick; floor; over 300mm wide; to slopes n e 15 deg; m2 0.33 ft2 0.03
2mm thick; floor; n e 300mm wide; level or to falls m 0.44 ft 0.13
2mm thick; floor; n e 300mm wide; to slopes n e 15 deg m 0.44 ft 0.13
extra for square cutting m 0.32 ft 0.10
extra for raking cutting m 0.32 ft 0.102mm thick; skirting; 100mm high; welded butt joints to sheet or tile flooring; cove former
m 0.17 ft 0.05
extra for internal angle nr 0.04 Nr 0.04
extra for external angle nr 0.04 Nr 0.04
3mm thick; floor; over 300mm wide; level or to falls; m2 0.65 ft2 0.06
3mm thick; floor; over 300mm wide; to slopes n e 15 deg; m2 0.65 ft2 0.06
3mm thick; floor; n e 300mm wide; level or to falls; m 0.78 ft 0.24
3mm thick; floor; n e 300mm wide; to slopes n e 15 deg; m 0.78 ft 0.24
extra for square cutting m 0.66 ft 0.20
extra for raking cutting m 0.66 ft 0.20
Extra over vinyl tiling; irrespective of thickness hot welding joint m 0.17 ft 0.05
2mm thick; flooring; over 300 mm wide; level or to falls m2 0.09 ft2 0.01
2mm thick; flooring; over 300 mm wide; to slopes n e 15 deg; m2 0.09 ft2 0.01
2mm thick; flooring; n e 300mm wide; level or to falls m 0.93 ft 0.28
2mm thick; flooring; n e 300mm wide; to slopes n e 15 deg m 0.93 ft 0.28
extra for square cutting m 0.16 ft 0.05
extra for raking cutting m 0.16 ft 0.05
2mm thick; skirting; 100mm high; cove former and capping. m 0.20 ft 0.06
extra for internal angle nr 0.05 Nr 0.05
extra for external angle nr 0.05 Nr 0.05
2.5mm thick; flooring; over 300 mm wide; level or to falls m2 0.69 ft2 0.06
2.5mm thick; flooring; over 300 mm wide; to slopes n e 15 deg m2 0.73 ft2 0.07
2.5mm thick; flooring; n e 300 mm wide; level or to falls m 0.93 ft 0.28
2.5mm thick; flooring; n e 300 mm wide; to slopes n e 15 deg m 0.93 ft 0.28
extra for square cutting m 0.16 ft 0.05
extra for raking cutting m 0.16 ft 0.05
2.5mm thick; skirting; 100 mm high; cove former and capping m 0.34 ft 0.10
extra for internal angle nr 0.05 Nr 0.05
extra for external angle nr 0.05 Nr 0.05
3.5mm thick; flooring; over 300mm wide; level or to falls m2 0.97 ft2 0.09
3.5mm thick; flooring; over 300mm wide; to slopes n e 15 deg m2 1.00 ft2 0.09
3.5mm thick; flooring; n e 300mm wide; level or to falls m 1.12 ft 0.34
3.5mm thick; flooring; n e 300mm wide; to slopes n e 15 deg; m 1.12 ft 0.34
extra for square cutting m 0.20 ft 0.06
extra for raking cutting m 0.20 ft 0.06
3.5mm thick; skirting; 100mm high; cove former and capping m 0.06 ft 0.02
flooring; over 300mm wide; level or to falls; m2 0.09 ft2 0.01
flooring; over 300mm wide; to slopes n e 15 deg; m2 0.42 ft2 0.04
flooring; n e 300mm wide; level or to falls; m2 0.56 ft2 0.05
flooring; n e 300mm wide; to slopes n e 15 deg; m2 0.56 ft2 0.05
extra for square cutting m 0.10 ft 0.03
extra for raking cutting m 0.10 ft 0.03
flooring; over 300mm wide, level or to falls m2 0.67 ft2 0.06
extra for square cutting m 0.05 ft 0.02
extra for raking cutting m 0.05 ft 0.02
Fix galvanised steel; stiffened expanded metal lathing;
Lay sheet safety flooring; welded joints; fix with adhesive
Lay carpet tile; size 500 x 500mm butt joints; fix with double sided tape
Lay sheet carpet; fixed at edge with tackless gripper; laid on wool felf underlay; jointed with seam tape
Lay thermoplastic tiling; size 300 x 300mm; fixed with adhesive; butt joints; laid symmetrical pattern;
Form
Lay vinyl tiling;size 300 x 300; fix with adhesive; butt joints; symmetrical pattern;
Lay vinyl tiling; size 450 x 450; fix with adhesive; butt joints; symmetrical pattern;
Lay sheet flooring; hot welded joints; fix with adhesive
Lay sheet flooring; hot welded joints; fix with adhesive
Lay clay floor tiling; size 150 x 150mm; bedded and jointed in cement mortar; laid symmetrical pattern; screeded base
356
flooring; over 300mm wide; level or to falls; m2 0.97 ft2 0.09
flooring; over 300mm wide; to slopes n e 15 deg; m2 0.97 ft2 0.09
flooring; n e 300mm wide; level or to falls; m2 1.18 ft2 0.11
flooring; n e 300mm wide; to slopes n e 15 deg; m2 1.18 ft2 0.11
extra for square cutting m 0.05 ft 0.02
extra for raking cutting m 0.05 ft 0.02
percentage adjustment; working in staircase area % 0.03 % 0.03
percentage adjustment; working in plant room % 0.03 % 0.03
aluminium; naplock carpet trim; single m 0.28 ft 0.09
aluminium; naplock carpet trim; double m 0.09 ft 0.03
stair nosing m 0.44 ft 0.13
carpet edging m 0.31 ft 0.09
copper grid system m 0.15 ft 0.04
Wall finish5.5mm thick wall covering; over 300mm wide; m2 1.03 ft2 0.10
5.5mm thick wall covering; n e 300mm wide; m 1.18 ft 0.365.5mm thick; wall covering; isolated areas n e 1m2; Nr 1.15 Nr 1.15
5.5mm thick; isolated beam; over 300mm wide; m2 1.03 ft2 0.10
5.5mm thick; isolated beam; n e 300mm wide; m 1.18 ft 0.36
5.5mm thick; isolated column; over 300mm wide; m2 1.03 ft2 0.10
5.5mm thick; isolated column; n e 300mm wide; m 1.18 ft 0.36
extra for square cutting m 0.05 ft 0.02
extra for raking cutting m 0.05 ft 0.02
plastered wall or column over 300 girth m2 0.08 ft2 0.01
plastered ceiling or beam over 300 girth m2 0.09 ft2 0.01
plastered wall or column over 300 girth m2 0.13 ft2 0.01
plastered ceiling or beam over 300 girth m2 0.14 ft2 0.01
brickwork or blockwork wall; over 300mm girth m2 0.21 ft2 0.02
cement render or concrete wall; over 300mm girth m2 0.20 ft2 0.02
isolated area; n e 300mm girth m 0.10 ft 0.03
plastered wall or ceiling ; over 300mm girth; m2 0.18 ft2 0.02
Extra for applying emulsion paint height allowance over 3.50 but n e 5.00m high m2 0.03 ft2 0.00
plastered wall or ceiling ; over 300mm girth; m2 0.24 ft2 0.02
Extra for applying emulsion paint height allowance over 3.50 but n e 5.00m high m2 0.03 ft2 0.00
wood surface; over 300mm girth m2 0.32 ft2 0.03
wood isolated surface; n e 300mm girth m2 0.13 ft2 0.01
wood isolated area n e 0.50m2 Nr 0.24 Nr 0.24
wood; glazed window; panes; area n e 0.10m2 m2 0.54 ft2 0.05
wood; glazed window; panes; area over 0.10m2 but n e 0.50m2 m2 0.43 ft2 0.04
wood; glazed window; panes; area over 0.50m2 but n e 1.00m2 m2 0.37 ft2 0.03
wood; glazed window; panes; area over 1.00 but ne 4.00m2 m2 0.32 ft2 0.03
metal surface; over 300mm girth m2 0.32 ft2 0.03
metal isolated surface; n e 300mm girth m2 0.13 ft2 0.01
metal isolated area n e 0.50m2 Nr 0.24 Nr 0.24
metal; glazed window; panes; area n e 0.10m2 m2 0.54 ft2 0.05
metal; glazed window; panes; area over 0.10m2 but n e 0.50m2 m2 0.43 ft2 0.04
metal; glazed window; panes; area over 0.50m2 but n e 1.00m2 m2 0.37 ft2 0.03
metal; glazed window; panes; area over 1.00 but ne 4.00m2 m2 0.32 ft2 0.03
wood surface; over 300mm girth m2 0.35 ft2 0.03
wood isolated surface; n e 300mm girth m2 0.15 ft2 0.01
wood isolated area n e 0.50m2 Nr 0.27 Nr 0.27
wood; glazed window; panes; area n e 0.10m2 m2 0.59 ft2 0.05
wood; glazed window; panes; area over 0.10m2 but n e 0.50m2 m2 0.59 ft2 0.05
wood; glazed window; panes; area over 0.50m2 but n e 1.00m2 m2 0.47 ft2 0.04
wood; glazed window; panes; area over 1.00 but ne 4.00m2 m2 0.35 ft2 0.03
metal surface; over 300mm girth m2 0.32 ft2 0.03
metal isolated surface; n e 300mm girth m2 0.13 ft2 0.01
metal isolated area n e 0.50m2 Nr 0.24 Nr 0.24
metal; glazed window; panes; area n e 0.10m2 m2 0.54 ft2 0.05metal; glazed window; panes; area over 0.10m2 but n e 0.50m2 m2 0.43 ft2 0.04
metal; glazed window; panes; area over 0.50m2 but n e 1.00m2 m2 0.37 ft2 0.03
metal; glazed window; panes; area over 1.00 but ne 4.00m2 m2 0.32 ft2 0.03
steelwork; general surface; over 300mm girth m2 0.29 ft2 0.03
percentage adjustment; working in staircase area % 0.03 % 0.03
percentage adjustment; working in plant rooms % 0.03 % 0.03
Prepare surface; touch up primer; apply two undercoats and one finishing coat oil gloss paint; internally
Prepare surface; touch up primer; apply two undercoats and one finishing coat oil gloss paint; externally
Prepare surface; touch up primer; apply two undercoats and one finishing coat oil gloss paint; externally
Extra over wall finish for
Extra over floor finish for
Fix; flooring accessories
Fix ceramic wall tile; size 152 x 152mm; butt jointed and fixed with approved adhesive; flush pointed with white grout
Prepare surface and apply; two coats of emulsion paint
Prepare, size and hang medium grade lining paper
Prepare, size and hang decorative vinyl wallpaper;
Lay rubber tiles; size 1.00 x 1.00; symmetrical pattern; fix with adhesive
Prepare surface; mask obstructions and protect adjacent areas; spray apply elastomeric paint system; carefully remove masking and protection on completion
Clean
floor finish; washable; over 300mm wide m2 0.01 ft2 0.00
floor finish; carpet; over 300mm wide m2 0.02 ft2 0.00
wall finish; washable; over 300mm wide m2 0.02 ft2 0.00
ceiling finish; washable; over 300mm wide m2 0.03 ft2 0.00
height allowance over 3.50 but n e 5.00m high % 0.10 % 0.10
height allowance over 5.00m high % 0.10 % 0.10
Clean down surface;
Extra over clean down surface for
357
Repair
floor finish; quarry tiles; in area n e 1.00m2 nr 0.25 Nr 0.25
floor finish; thermoplastic tiles; in area n e 1.00m2 nr 0.25 Nr 0.25
floor finish; vinyl tiles;in area n e 1.00m2 nr 0.20 Nr 0.20
floor finish; vinyl sheet flooring; in area n e 1.00m2 nr 0.20 Nr 0.20
floor finish; safety flooring; in area n e 1.00m2 nr 0.20 Nr 0.20
floor finish; carpet tiles; in area n e 1.00m2 nr 0.15 Nr 0.15
floor finish; rubber tiles; in area n e 1.00m2 nr 0.20 Nr 0.20
floor finish; sheet carpeting; in area n e 1.00m2 nr 0.20 Nr 0.20
wall; wallpaper and lining paper; in area n e 0.50m2; nr 0.20 Nr 0.20
wall; elastomeric paint; in area n e 0.50m2 nr 0.30 Nr 0.30
wall; ceramic tiles; in area n e 0.50m2 nr 0.35 Nr 0.35
ceiling; wallpaper and lining paper; in area n e 0.50m2; nr 0.20 Nr 0.20
ceiling; elastomeric paint; in area n e 0.50m2 nr 0.30 Nr 0.30
Take up loose material, clean and prepare surface and refix with approved adhesive;
Clean down, remove loose or damaged material; prepare background and apply approved material; surface finish to match existing;
Replace
Removal only. Replacement use NEW rates
floor preparation; screed; over 300mm wide m2 0.15 ft2 0.01
floor finish; clay tiles; over 300mm wide m2 0.20 ft2 0.02
floor finish; thermoplastic tiles; over 300mm wide m2 0.10 ft2 0.01
floor finish; vinyl tiles; over 300mm wide m2 0.10 ft2 0.01
floor finish; vinyl sheet flooring; over 300mm wide m2 0.10 ft2 0.01
floor finish; safety flooring; over 300mm wide m2 0.10 ft2 0.01
floor finish; carpet tiles; over 300mm wide m2 0.05 ft2 0.00
floor finish; rubber tiles; over 300mm wide m2 0.10 ft2 0.01
floor finish; sheet carpeting; over 300mm wide m2 0.20 ft2 0.02
wall preparation; plaster; over 300mm wide m2 0.33 ft2 0.03
wall preparation; render; over 300mm wide m2 0.25 ft2 0.02
ceiling preparation; plaster; over 300mm wide m2 0.68 ft2 0.06
height allowance over 3.50 but n e 5.00m high % 0.10 % 0.10
height allowance over 5.00m high % 0.10 % 0.10Hack off and remove material; including bed or backing; clean prepare backgound surface to receive new surfacing
wall finish; ceramic tiles; over 300mm wide m2 0.83 ft2 0.08wall finish; wallpaper and lining paper; over 300mm wide m2 0.10 ft2 0.01
wall finish; elastomeric paint; over 300mm wide m2 0.12 ft2 0.01
ceiling finish; wallpaper and lining paper; over 300mm wide m2 0.10 ft2 0.01
ceiling finish; elastomeric paint; over 300mmm wide m2 0.12 ft2 0.01
height allowance over 3.50 but n e 5.00m high % 0.10 % 0.10
height allowance over 5.00m high % 0.10 % 0.10
extra over remove wall and ceiling finish for
Hack off and remove material; rake out joint or hack face of background to form key for in-situ finish
Hack up or take up material, remove all adhesive, level and prepare to receive new finish
extra over wall and ceiling preparation for
Carefully remove surface finish , fill with approved material, level surface finish and prepare to receive new surfacing
358
R.1 Fireproofing Norms
Fabricate & Install Fireproofing to Walls, Ceilings & Ductwork
NormA60 Rated without lining and vapour barrier m2 0.90A60 Rated with vapour barrier but without lining m2 1.00A60 Rated with Stainless/Galv Steel lining but without vapour barrier m2 2.60A60 Rated with Stainless/Galv Steel lining and vapour barrier m2 2.80
Norm Norm Norm Norm Norm Norm NormCement Based m2 2.500 2.550 2.700 2.900 3.050 3.200 3.350Epoxy Based m2 2.600 3.000 3.400 3.900 4.400 4.900 5.500
30mm Thick
Unit
Unit
75mm Thick
Fireproofing Thickness
Install Fireproofing to any surface
Fireproofing Thicknessn.e. 10mm
Thick15mm Thick 20mm Thick 35mm Thick 40mm Thick25mm Thick
359
S.1 Safety & Loss Prevention Norms
Install Fire Fighting & Safety Equipment
UnitNorm
Fire etinguishers Nr 4.00 Hydrants Nr 16.00 Hose Reels Nr 8.00 Dual Agent Hose Reels Nr 24.00 Monitors Nr 16.00 Fireman's Equipment Cabinet Nr 32.00 Survival Suit and Life Jacket Lockers Nr 16.00 Lifebuoys Nr 5.00 Eyewash Stations Nr 4.00 Breathing Apparatus Cabinets Nr 12.00 Safety Shower with Eyewash Nr 8.00 Deluge and Sprinkler Skid Nr 160.00 Escape Chute System Nr 200.00 Free Fall Lifeboat Nr 400.00 Miscellaneous Items & Equipment N.Exc. 25Kg each Nr 8.00
Install