gyplyner universal metal framed wall lining system · gyplyner universal metal framed wall lining...
TRANSCRIPT
Cadbury offices,
Bournville, Birmingham
266
GypLyner UNIVERSAL
Metal framed wall lining system
This section includes updated information, added
since it was first published in July 2009. Please see
the WHITE BOOK update document for details.
Last updated 05/07/2010!
3
Gyp
Wal
lRA
PID
and
RA
PID
dBPl
usG
ypLy
ner
UN
IVER
SAL
267
7
Key facts
Gypframe GL1
Lining ChannelGypframe GL2
or GL9 Bracket
A B
49 66GypLyner UNIVERSAL
GypLyner UNIVERSAL wall lining system is a cost-effective, virtually
independent metal frame drylining. It is a general purpose
system that is suitable for all internal non-loadbearing
applications.
+
W/m2K
0.53 0.22
A
B
● Commonality of ceiling and wall lining components
● General purpose lining
● Minimal connection to the structure
● Overcomes difficulties of background irregularities
● Can satisfy thermal performance and acoustic requirements
● Provides service void of 25mm - 125mm
● Ideal for refurbishing existing walls where:- wall surface quality
is poor- acoustic or thermal
upgrades are required- a cavity is required to
accommodate services, such as waterand waste pipes
C
C
Gypframe
GL8 Track
C
+
Applications
Rw dB
SectorOffice / commercial
Education
Housing
Retail
Healthcare
Apartment buildings
Sport and leisure
Industrial
High-rise multi-occupancy
✓
✓
✓
✓
✓
✓
✓
✓
✓
Due to the design flexibility of GypLyner UNIVERSAL, this system can be tailored to meet the requirements of a widerange of applications.
Always use genuine branded British Gypsum components to qualify for SpecSure® lifetime warranty
Gyp
Lyn
er U
NIV
ERSA
L
268
www.british-gypsum.com
7
LIF
ET
IME
S Y S T E M W
AR
RA
NT
Y
SPECSURE
System components
Board products
Gypframe metal products
GL1 Lining Channel Length
2400, 2700mm
3000, 3600mm
GL3 Channel Connector
Gypframe GL11 GypLyner Anchors
For fixing Gypframe GL2, GL9 or GL12 Brackets to
concrete / masonry.
Gyproc Sealant
Sealing air paths for optimum sound insulation.
Gyproc jointing materials
For seamless jointing.
Isover APR 1200
25mm or 50mm, for improved acoustic
performance.
Fixing and finishing products
Gyproc SoundBloc1
Thickness 12.5, 15mm
Width 1200mm
Gyproc WallBoard1
Thickness 12.5, 15mm
Width 900, 1200mm
GL2 Bracket Length
For maximum 75mm 195mm
stand-off from wall.
Gyproc Drywall Screws
For fixing boards to Gypframe metal framing and
brackets to timber supports.
GL8 Track Length
3600mm
GL9 Bracket Length
For maximum 125mm 295mm
stand-off from wall.
Gyproc Wafer Head Drywall Screws
For metal-to-metal fixing up to 0.79mm thick.
Thistle Board Finish or Thistle Multi-Finish
To provide a plaster skim finish.
or
Thistle Durafinish
To provide improved resistance to accidental damage.
99 FC 50 Fixing Channel Length
2400mm
GFT1 Fixing ‘T’ Length
2400mm
150 FC 90 Length
Fixing Channel 1197mm
GFS1 Fixing Strap Length
2400mm
Gyproc WallBoard DUPLEX
Thickness 12.5, 15mm
Width 900, 1200mm
Board products (continued)
Gyproc DuraLine1
Thickness 15mm
Width 1200mm
Gyproc ThermaLine boards
Thickness 22 - 90mm
Width 1200mm
Gyproc edge and angle beads
Protecting and enhancing board edges and corners.
Gyproc Control Joint
To accommodate structural movement.
1 Moisture resistant boards are specified in intermittent wet use areas,
e.g. shower cubicles.
DUPLEX grade board is used as an external wall lining to control water vapourtransmission.NB
Isover CWS
50mm, for improved thermal and acoustic
performance.
Service Support Plate Length
For the installation of 130mm
plywood within a
partition cavity.
Insulation products
269
T 0844 800 1991 F 0844 561 8816 E [email protected]
Gyp
Lyn
er U
NIV
ERSA
L
7
Installation overview
For full installation details, refer to the British Gypsum SITE BOOK, available to download from www.british-gypsum.com
The required cavity depth up to a maximum of 125mm is
determined, and chalk lines marked to floor and ceiling to indicate
positioning of the Gypframe GL8 Track. Gypframe GL8 Track is fixed to
perimeters using appropriate fixings. Vertical lines are marked on
the wall at appropriate intervals to indicate Gypframe GL2 or GL9
Bracket fixing centres. Horizontal lines are marked at appropriate
centres to determine individual bracket positions. Brackets are then
fixed into position.
Gypframe GL1 Lining Channels are friction-fitted into the track,
extending if required. Bracket legs are bent forward and each leg
fixed to the Gypframe GL1 Lining Channel. The protruding bracket
legs are bent back to sit clear of the channel face.
At internal angles, a Gypframe GL1 Lining Channel is positioned tight
into the corner to provide support for the lining. Boards are fixed to all
framing members.
Openings
Gypframe GL1 Lining Channel is positioned either side of the door
opening and fixed to the Gypframe GL8 Track at head and base.
A section of Gypframe GL8 Track is cut and bent to form the head of
the opening. Short lengths of Gypframe GL1 Lining Channel are
positioned above the opening to provide additional support and to
maintain appropriate support centres. At window openings, Gyproc
edge bead is fixed to the perimeter of the window frame to protect
and retain the lining. See Construction details – 5.
For full installation details, refer to the British Gypsum
SITE BOOK, available to download from www.british-gypsum.com
270
www.british-gypsum.comG
ypLy
ner
UN
IVER
SAL
7
Performance ( Refer to section 3 - Basic principles of system design)
Table 1 – GypLyner UNIVERSAL new-build - meeting thermal insulation requirements for external cavity walls
LIF
ET
IME
S Y S T E M W
AR
RA
NT
Y
SPECSURE
1
Brick / cavity / block wall comprising 103mm
brick skin, 50mm clear cavity, block inner leaf.
Linings as in table.
Brick / cavity / block wall comprising 103mm
brick skin, 50mm Isover CWS, block inner leaf.
Linings as in table.
2
Detail Board Lining Minimum Minimum U-value
type thickness overall wall GypLyner UNIVERSAL
ThermaLine SUPER 40 318 25 0.35
ThermaLine SUPER 60 338 25 0.26
ThermaLine SUPER 90 368 25 0.19
ThermaLine PLUS 27 305 25 0.31
ThermaLine SUPER 30 308 25 0.28
ThermaLine PLUS 40 318 25 0.27
ThermaLine SUPER 60 338 25 0.31
ThermaLine SUPER 70 348 25 0.27
ThermaLine SUPER 90 368 25 0.22
ThermaLine PLUS 35 313 25 0.34
1
1
2
1
1
2
2
2
1
1
Aircrete block (λ = 0.11 W/mK) inner leaf
Medium density block (λ = 0.47 W/mK) inner leaf
Calculations are based on the proportional area and combined methods for determining U-values of structures containing repeated thermal bridges in accordance with BS EN ISO 6946.
NB
NBS work section K10 - Plasterboard drylinings / partitions / ceilings
Table 2 – GypLyner UNIVERSAL refurbishment - upgrading thermal insulation of external walls
271
T 0844 800 1991 F 0844 561 8816 E [email protected]
Gyp
Lyn
er U
NIV
ERSA
L
7
LIF
ET
IME
S Y S T E M W
AR
RA
NT
Y
SPECSURE
1 2
Brick / cavity / brick wall comprising 103mm
cavity brick skin. 50mm clear cavity, 103mm
inner brick plastered. Linings as in table.
Solid brick wall (215mm) with inner face plastered.
Linings as in table.
Detail Board Lining Minimum Minimum U-value
type thickness overall wall GypLyner UNIVERSAL
ThermaLine PLUS 40 334 25 0.53
ThermaLine SUPER 60 354 25 0.31
ThermaLine SUPER 70 364 25 0.27
ThermaLine SUPER 50 303 25 0.41
ThermaLine SUPER 70 323 25 0.29
1
1
2
1
2
Outer brick (λ = 0.77 W/mK), inner brick (λ = 0.56 W/mK), solid brick (λ = 0.75 W/mK)
1 Subject to severity of exposure and weathertightness.2 Including 25mm Isover APR 1200 in the GypLyner UNIVERSAL cavity / framing.
Calculations are based on the proportional area and combined methods for determining U-values of structures containing repeated thermal bridges in accordance with BS EN ISO 6946.
NB
NBS work section K10 - Plasterboard drylinings / partitions / ceilings
1
272
www.british-gypsum.comG
ypLy
ner
UN
IVER
SAL
7NBS work section K10 - Plasterboard drylinings / partitions / ceilings
Performance ( Refer to section 3 - Basic principles of system design)
Table 3 – GypLyner UNIVERSAL refurbishment - upgrading sound insulation of solid internal walls
LIF
ET
IME
S Y S T E M W
AR
RA
NT
Y
SPECSURE
1 2 3
4 5
SoundBloc 1 x 12.5 49 (43) +2 (-1) B226009
SoundBloc 1 x 12.5 57 (50) +10 (+6) B226008
SoundBloc 1 x 12.5 60 (42) +13 (-2) B226010
SoundBloc 1 x 12.5 57 (50) +10 (+6) B226008
SoundBloc 2 x 12.5 60 (55) +13 (+11) B226003
SoundBloc 1 x 12.5 64 (56) +17 (+12) B226007
SoundBloc 2 x 12.5 66 (59) +19 (+15) B226005
2
1
5
5
4
4
3
Detail Board Lining Sound insulation System
type thickness Improvement over reference
existing wall
Rw (Rw + Ctr) Rw (Rw + Ctr)
mm dB dB
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmedaccording to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixingrecommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum.
NB
Solid brick wall (103mm) with 13mm plaster each
side and Gypframe GL1 Lining Channel framework
fixed to one side to give 35mm cavity.
Lining as in table.
Solid brick wall (103mm) with 13mm plaster each
side and Gypframe GL1 Lining Channel framework
fixed to one side to give 35mm cavity. Cavity filled
with 25mm Isover APR 1200.
Lining as in table.
Solid brick wall (103mm) with 13mm plaster each
side and Gypframe GL1 Lining Channel framework
fixed to both sides to give 35mm cavities. Cavities
filled with 25mm Isover APR 1200.
Linings as in table.
Solid block wall, of mass 200kg/m2, with 13mm
plaster each side. Gypframe GL1 Lining Channel
framework fixed to one side to give 35mm cavity.
Cavity filled with 25mm Isover APR 1200.
Linings as in table.
Solid block wall, of mass 200kg/m2, with 13mm
plaster each side. Gypframe GL1 Lining Channel
framework fixed to one side to give 85mm cavity.
Cavity filled with 50mm Isover APR 1200.
Linings as in table.
273
T 0844 800 1991 F 0844 561 8816 E [email protected]
Gyp
Lyn
er U
NIV
ERSA
L
7
Design
Planning - key factors
The depth of the cavity is determined by the positioning of the
fixing brackets. Allow for a stand-off of 25mm - 75mm plus the
lining thickness for Gypframe GL2 Brackets, and 25mm - 125mm
plus the lining thickness for Gypframe GL9 Brackets. These
stand-offs are sufficient to correct irregularities normally
encountered in solid backgrounds. The stand-off will determine the
lining dimension required at door and window reveals and soffits.
Ceilings should be installed prior to installing GypLyner UNIVERSAL
wall linings. Any abutting partitions should also be installed prior
to drylining.
Cavity barriers
Building Regulations may require the provision of vertical cavity
barriers to long runs of lining. Minimum 12.5mm plasterboard, cut
to cavity depth and screw-fixed to the leg of Gypframe GL1 Lining
Channel, will provide a satisfactory cavity barrier.
Refer to section 10 – Cavity fire barriers.
Thermal performance
Uncontrolled air movement through the drylining cavity can result
in excessive heat loss from the building. The quoted U-values for
GypLyner UNIVERSAL wall lining are based on a sealed cavity between
the lining and the background. This is achieved in practice if the
abutting elements and the background are well fitted, and
junctions are sealed.
When the perimeter of the cavity is to be sealed by the drylining
contractor, the recommended method is to apply a continuous
fillet / ribbon of Gyproc Dri-Wall Adhesive or Gyproc Sealant to the
perimeter of the external wall and around any openings.
The designer should also specify a method of restricting air
movement around the perimeter of suspended timber floors, such
as the provision of a flexible seal between the floor and walls.
Good standards of thermal insulation can be achieved where
Gyproc ThermaLine laminates are specified as the lining. There
may, however, be a slight risk of pattern staining where
temperature, humidity, and soiling conditions are extreme.
Wall lining rigidity
Brackets should be positioned equidistant at maximum 800mm
vertical centres. Where there is a requirement for increased rigidity,
these support centres should be reduced accordingly, although
acoustic performance may be downgraded. Gypframe GL11
GypLyner Anchors are recommended for fixing brackets to the solid
background.
Services
The cavity between the metal framework and the background
facilitates the incorporation of services. Pipes and conduits should
be fixed in position before installing the framing.
When installing Gyproc ThermaLine laminates, the insulation
should not be chased to accommodate services. PVC covered cables
must not come into contact with polystyrene insulation. Suitable
isolation methods such as conduit or capping should be used.
Refer to section 3.5 – Service installations.
Fixtures
Lightweight fixtures can be made directly to the lining. Medium
weight fixtures should be made to Gypframe 99 FC 50 Fixing
Channel. Heavyweight fixtures (to BS 5234), such as wash basins
and wall cupboards, can be fixed using Gypframe 150 FC 90 Fixing
Channel.
Refer to section 3.5.2 – Service penetrations and fixing into
drywall systems.
Board finishing
Refer to section 13 – Finishing systems and decorative effects.
For more information refer to the British Gypsum SITE BOOK,
available to download from www.british-gypsum.com
Please refer to section 3 - Basic principles of system design for general guidance
Cabling
Soil pipes
Central heating and waste pipes
274
www.british-gypsum.comG
ypLy
ner
UN
IVER
SAL
7
Construction details
External angleHead and base
Gyproc plasterboard
Gypframe GL1 Lining Channel
Gypframe GL2 or GL9 Bracket fixed with Gypframe GL11 GypLyner Anchor
Gypframe GL8 Track
Gyproc Sealant
Bulk fill with Gyproc jointing materials (where gap exceeds 5mm)
Wall structure
Skirting
Gypframe ‘C’ Stud
Gyproc Drywall Edge Bead
Window frame
1
1 2
234
7
Internal angle3
Partition junction 4
89
5
3
11
1
32
10
7
5
4
2
7
1
3
2
1
7
8
7
2
3
56
10
4
1
2
Window reveal5
3
9
2
7
1
1
4
6
5
11
4