H E M ATO L O GYS TAINER / CYTO C E N T R I F U G E

The AerosprayHematology SlideStainer/Cytocentrifugeintroduces an exciting new concept forthe clinical laboratory—two essentialinstruments in one economicalpackage. With Wescor's optionalCytopro® rotor, Aerospray becomes asuperb cytocentrifuge featuring 8-slidecapacity and keyboard program-mability. All at a fraction of the cost ofa stand-alone cytocentrifuge!

As a HematologySlide StainerAerospray offers three majoradvantages:

1. Rapid and consistent staining

2. Easy user programmability

3. Miserly use of reagent

Plus proven quality and reliability.

U.S. Patent Nos. 4,004,550; 4,089,989; 5,180,606; 5,009,185; 5,252,228. Other Patents Pending.

h eN ewe s t

I n n ovation I s

H e re !w i t h

miserly economyunsurpassed speed

&exceptional quality

T

Rapid PerformanceWith a cycle time less than 4minutes, the AerosprayStainer is ideal for STATS, butwith a throughput of morethan 180 slides per hour, ithandles heavy loads easily. Ineither case, slides emerge dryand ready for the microscope.

Reagent EconomyReagent is applied to individ-ual slides in the carousel asan atomized spray. Reagentdelivery conforms with thenumber of slides beingstained in any given run.Consequently, stain consump-tion is conservative andreagent costs are significantlyminimized.

U s e r - P r o g r a m m a b i l i t yThe Aerospray Stainer is easi-ly programmed. You have achoice of 10 intensity settingsincluding 3 settings for bonemarrow. The instrument isthus highly responsive to awide range of stainingrequirements. Simply makeyour selection by pressing asingle keypad.

Optional Rotor forC y t o c e n t r i f u g a t i o nFor the cost of the optionalCytopro Rotor, the AerosprayStainer becomes a superbcytocentrifuge with eight-slidecapacity and keyboard pro-grammability at a fraction ofthe cost of purchasing astand-alone cytocentrifuge.

C o n v e n i e n tThe Aerospray Stainerincludes an operator initiatedclean cycle that reducesmaintenance to a minimum.It's a clean, no-fuss processfrom start to finish.

Ready for the Microscope in 4 Minutes

mears areautomatically fixedwith methanol or with

Aerofix® fixative at thebeginning of the staining cycle(alternatively, slides can behand-fixed using methanol orBasofix®). After a dryingsequence, eosin stain isapplied to stain acidophilic cellcomponents, followed by abrief period for stain penetra-tion. Thiazin dye is then applied

to stain the basophilic cell com-ponents, followed by anotherbrief stain penetration period.

A buffered rinse cleans theslides of excess stain and isthen removed by centrifugation.Slides are dry and ready for themicroscope at the end of thecycle.

The Romanowsky StainThe Aerospray Stainer uses atwo-part aqueous Romanowskystain. Its principal advantagesare:

Rapid staining kinetics Blood smears are fixed,stained, and dried in about 3.5 minutes.

Improved stain stabilityThe slow rate of decompositionof thiazin and eosin dyes inseparate neutral aqueous solu-tions allows a long shelf life.Since changes in the stainsoccur very slowly, stainingresults are highly reproducibleand consistent.

Clear fieldsSince there is virtually no stainprecipitation or debris, slidesare exceptionally clean.

Reagent concentratesAll Wescor hematologyreagents can be prepared fromconcentrate to help defray ship-ping costs and to satisfy specif-ic customer needs, such asneutrophil and overall colorpreferences.

BasofixWith aqueous stains, basophilgranules, which are water solu-ble, may be washed away inthe staining process, but withexperience, degranulatedbasophils are readilyrecognized.

For customers who prefer gran-ulated basophils, Wescor offersBasofix fixative. This speciallycompounded formula yieldsstain coloration morereminiscent of alcohol-basedstains. In addition to fixingbasophil granules, primarygranules are alsostrengthened.

Answering today'slaboratory needsIn the face of rising health carecosts, any capital outlay mustreturn maximum benefit forevery dollar spent. Thepressures of tight budgets, pro-ductivity demands, and theneed for diagnostic integritymake investment in theAerospray Hematology SlideStainer/Cytocentrifuge a choicethat will please both themedical technologist and thelaboratory administrator.

The Wescor Staining Process for H e m a t o l o g yS

Slides are exceptional-ly clean. Most fieldsare literally free of pre-cipitation or staindebris.

C Y T O P R O®

Cytocentrifuge Rotor

ith the optional Cytoprorotor, the Aerospraystainer becomes a

cytocentrifuge at a fraction ofthe cost of a stand-alone cyto-centrifuge. There’s no modifica-tion or fiddling involved. Simplyremove the staining carouseland replace it with the Cytoprorotor.

The self-contained rotor loadseasily in a safety cabinet. Anairtight seal controls biologicalhazards. The rotor and samplechambers are autoclavable.Sample chambers are competi-tively priced so you can eco-nomically dispose of them.

THE CYTOPRO CHAMBERThe chamber’s unique designcombines ease of use withsuperb cell recovery.

-Perfect Alignment. TheCytopad®absorption pad snapsquickly between the chamberand the frame. This guaranteesthat the chamber bore is alwayscorrectly aligned. No fumbling,and no cell loss due to pooralignment.

-Better Flow Control. EachCytopad features a specially-compressed ring around thecenter hole. This compressioncontrols the fluid flow andimproves the repeatability offluid absorption.

-Dual Sample Port. Two ports,one in the sample well and onein the tunnel, provide great ver-satility, allowing you to introduceprewetting fluids and making insitu fixation easy and reliable.

-Chamber Caps. You can loadsamples directly through thechamber caps to preventspilling of hazardous samples.

-Two Fluid Absorption Rates.The white Cytopad is for fasterabsorption of thick or debris-filled suspension fluids. The tanpad is used to slow fluidabsorption for improved cellrecovery in non viscous fluidssuch as urine or CSF.

EASY TO ASSEMBLE ANDLOADAssembling the Cytopro cham-ber is very easy. No fumblingwith a spring-loaded assembly.Chambers and Cytopads fitsecurely together with foolproofprecision. No more cell lossbecause of misaligned filtercards. You’ll be surprised howsimply chambers and slidesload into the rotor. The ends ofeach slide are fully visible toyou for accurate patient identifi-cation.The rotor bowl’s shallow profilemakes sample loading moreconvenient than with a deeprotor. Simply pipette sample

fluid directly into the samplewell (maximum sample size: 0.5mL) or through vents in thechamber caps. The semi-trans-parent sample chamber allowsvisual confirmation of correctsample volume.

THE CHOICE IS YOURSCytopro delivers the versatilityyou need to satisfy a wide vari-ety of sample treating require-ments:

-Unparalleled ease of use-Simple and flexible program-ming

-Superior sample chamberdesign-Choice of two fluid absorptionrates -In situ fixation-Convenient prewetting capabili -ty-Safety and reliability

Finally, you have the flexibilityto control the cytocentrifugationprocess and to set the level ofeconomy. The choice is yours.

W

Instrument SpecificationsA e r o s p r a y® Hematology Slide Stainer/Cytocentrifuge Model 7120

Slide Carousel Capacity 1 to 12 Slides

Carousel Rotation Speed Reagent application 20 RPM, Slide drying approximately 1000 RPM

Cytocentrifuge Rotor Speed Programmable, 100 to 2000 RPM

Display 4 line by 16 character alpha-numeric LCD dot-matrix

Touch Pad Controls 10 Stain intensity selections, 10 Numeric Programming Keys, Run, Stop, Clean, Prog, CytoCent, Volume Test

Slides per Maximum 1200 (12 slides/run) 500 mL stain pack Minimum 600 (2 slides/run)at medium setting

Operating Time 210-246 seconds, depending upon intensity setting (fix on)

Dimensions (W x H x D) 56 cm x 24 cm x 53 cm (22” x 9.5” x 21”)

Clearance Height (lid open) 58 cm (23”)

Weight 16.8 kg (37 lb)

Electrical Requirements 100V, 120V, 220V, or 240V @ 50-60 Hz (user selectable), 75 watts

Drain Connection Nipple on rear panel

Safety Lid interlock: Lid must be closed, and is locked down during operation

C y t o p r o® Cytocentrifuge Rotor Cat. No. AC - 060

Capacity 8 chambers / slides

Weight 1.3 kg (2.75 lb)

Dimensions (Dia. x H) 23 cm x 4.8 cm (9.0" x 1.875")

For information regarding Aerospray® automatic Gram or Papanicolaou stainers, contact :

WESCOR, INC459 South Main Street, Logan, Utah 84321 USATELPHONE:

800 453 2725435 752 6011FAX:

435 752 4127E-MAIL:

[email protected] WEB PAGE:

www.wescor.com