h7960 3g 4g router user manual -...

91
User Manual H7000 Series DTU www.hongdian.com

Upload: dodieu

Post on 15-Sep-2018

229 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

User Manual H7000 Series DTU

www.hongdian.com

Page 2: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Doc. Version V2.1 ii

H7000 Series DTU User Manual

We Hongdian provide full support to customers, contact us freely if any questions.

Shenzhen Hongdian Technologies Corporation

Address F14-16,Headquarter Economic Center Building, Zhonghaixin Science&Tech Park, Bulan Road, Longgang District, Shenzhen

Website http://www.hongdian.com

Technical Support +86-0755-88864288-4/8238

Fax number 0755-83404677

Email [email protected]

Copyright © Shenzhen Hongdian Technologies Corporation. 2017. All rights reserved.

All information in this user manual is protected by copyright law. Whereby, no organization or individual shall copy or reproduce the whole or part of this user manual by any means without written authorization from Shenzhen Hongdian Technologies Corporation.

Trademarks and Permissions

and DTU are the trademarks and logos of Shenzhen Hongdian Technologies Corporation. Other trademarks and logos mentioned in this manual belong to other organizations related. Shenzhen Hongdian

Technologies Corporation does not own the rights of other trademarks and logos.

Caution

Due to product updates or functional upgrading, we may renew the content of this file, and this file only for referenc e. All statement, information, suggestion.etc in this file do not compose any form of guarantee and we

Hongdian reserves the right of final explanation.

Page 3: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Doc. Version V2.1 iii

H7000 Series DTU User Manual

Foreword

Summary H7000 series DTU is one of the company's wireless communication systems. The device provides standard RS-232/RS-485/RS-422/TTL (H7000E currently provides TTL interface)

level interface, can provide users with a variety of high quality, transparent data transmission of wireless data networks.

Among them, H7000E DTU is the H7000 wireless DDN communication system products in the smallest size, the lowest power consumption products. The device is suitable for embedded applications to meet customer requirements for embedded, low power consumption, etc.

By reading this document, you can understand the characteristics of the product features, hardware interface description, terminal configuration and the main function of the use and configuration methods.

Product Version The product version corresponding to the document is as shown below.

Product name Product version

H7710 DTU V50 or higher version,4G

H7210 DTU V50 or higher version, GPRS

H7710E Embeded version, V50 or higher,4G

H7210E DTU Embedded version, V50 or higher, GPRS

Readers The document applies to the following persons:

R & D engineers Technical support engineers Customers

Page 4: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Doc. Version V2.1 iv

H7000 Series DTU User Manual

You are recommended to start from Chapter One if you know and use any Router product

of Hongdian for the first time so as to get a better understanding of the product and the correct usage by reading all the contents of the document.

You are recommended to select any chapter or section you want to know via the contents below if you have known or used any Router product of Hongdian or a similar product of

any other company.

Modifying Records Modifying records accumulate the introduction of every document update. The document of the newest version includes all updating contents of previous document versions.

Doc. Version Time Note

V1.9 2016-08-15 The manual was firstly released for the DTUs with

hardware version V50 or higher.

(If your DTU is low version, such as V32, please read previous DTU user manual)

V2.1 2017-11-28 Update contents.

Page 5: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Doc. Version V2.1 v

H7000 Series DTU User Manual

Contents

Foreword .......................................................................................................................................... 3

1 Product Introduction .................................................................................................................... 1

1.1 Summary .............................................................................................................................................................................1

1.2 Product orientation ...........................................................................................................................................................1

1.3 Equipment accessories and model description ............................................................................................................6

1.4 Equipment appearance.....................................................................................................................................................7

2 DTU Installation ............................................................................................................................ 1

3 Application Guide ......................................................................................................................... 1

3.1 Summary .............................................................................................................................................................................1

3.2 Optimal transmission mode.............................................................................................................................................1

3.3 Transparent TCP transmission mode (Single center) ..................................................................................................4

3.4 TCP+DDP transmission mode (single center)................................................................................................................7

3.5 Transparent UDP transmission mode (Single center) .............................................................................................. 13

3.6 UDP+DDP transmission mode (single center)............................................................................................................ 16

3.7 Short message (SMS) transmission mode .................................................................................................................. 22

3.8 SMS remote parameter management ........................................................................................................................ 26

3.9 Wake up mode ................................................................................................................................................................ 32

3.10 APN/VPDN network transmission ............................................................................................................................. 38

3.11 Multi center transmission mode................................................................................................................................ 40

3.12 Main standby center transmission mode................................................................................................................. 45

3.13 TCP Server (server) mode transmission mode ........................................................................................................ 52

3.14 DSC remote parameter management....................................................................................................................... 53

3.15 Remote upgrade software .......................................................................................................................................... 55

3.16 Independent service channel and management channel ..................................................................................... 56

3.17 Cloud management platform for DTU ...................................................................................................................... 59

3.17.1 DTU access cloud platform ............................................................................................................................... 59

3.17.2 DTU parameter query........................................................................................................................................ 61

3.17.3 DTU parameter setting...................................................................................................................................... 62

3.18 Alarm function (Optional) ........................................................................................................................................... 62

3.18.1 Function introduction........................................................................................................................................ 62

3.18.2 Alarm mode......................................................................................................................................................... 62

Page 6: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Doc. Version V2.1 vi

H7000 Series DTU User Manual

3.18.3 Trigger mode....................................................................................................................................................... 63

3.18.4 Parameter setting format ................................................................................................................................. 64

4 FAQ ................................................................................................................................................ 1

4.1 H7000 series DTU is unable to communicate with external devices........................................................................1

4.2 Unable to connect to the tool using the DTU Tool configuration parameters .......................................................1

4.3 DTU send text messages to the phone display garbled ..............................................................................................2

4.4 DTU cannot resolve DSC domain name .........................................................................................................................2

4.5 Local software upgrade ....................................................................................................................................................3

4.5.1 H7000 upgrade tools upgrading ...........................................................................................................................3

4.5.2 Integrated tool box upgrading ..............................................................................................................................3

Terms ................................................................................................................................................ 1

Abbreviation .................................................................................................................................... 2

Page 7: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 1

H7000 Series DTU User Manual

1 Product Introduction

1.1 Summary H7000 series DTU products provide a wireless communication link between terminal equipment and data service center (platform) for customers by 2G, 3G, 4G cellular networks.

H7000 2G DTU is a wireless DDN network data communications product based on GPRS/GSM/CDMA. H7000 4G DTU is another wireless data communications product based on 4G network (TDD-LTE, FDD-LTE, down compatible with

WCDM/EVDO/TD-SCDMA/EDGE).

Besides, H7000-V5X and H7000-V6X are with dual serial port function, in which one port for debug, another for data transfer, so that the debugging information can be view while the data port is sending data.

Hongdian H7000 series DTU also passed the third party certification EMC and EPRI EMC four level test.

1.2 Product orientation H7000 series DTU is positioned as an industrial wireless transmission equipment, in order

to solve the problem of remote transmission of data in various industries.

H7000 series DTU products correspond to the transport layer products in the Internet of things architecture. According to the different needs of customers, this series of products can meet the needs of different applications (wherein, our embedded products can meet the requirements of embedded applications), and meet the requirements of low power consumption.

Its application is very extensive, for example:

Power system distribution network monitoring and large customer meter reading Monitoring of tap water and gas pipeline Environmental monitoring stations located in factories, streets and fields Hydrological monitoring and flood control, drought and wind data collection Transmission of parking spaces and traffic monitoring data Meteorological station data acquisition Financial system POS (Point Of Sales) networking Taxi scheduling and management Vehicle scheduling management in logistics system

Page 8: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 2

H7000 Series DTU User Manual

Information management of trans regional enterprises

The applications of the DTU in the actual network are shown as Figure 1-1 and Figure 1-2.

Figure 1-1 H7000 DTU situation

Figure 1-2 H7000E DTU situation

Power industry applications (remote meter reading)

The power remote meter reading system is composed of the distribution center located in

the electric power bureau and the meter data collection point in the residential area. It makes use of the existing wireless network to transmit data through wirele ss network of wireless operators. All the meters of residential area are firstly connected to the electricity meter concentrator through the RS-485 serial port, and the concentrator meter is connected to the DTU (2G/3G/4G transparent data transmission unit) via the RS-232 port, to transmit the data to the data distribution center via the cellular network. Typical applications such as Figure 1-3 network shows. Typical application network is shown as Figure 1-3.

Page 9: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 3

H7000 Series DTU User Manual

Figure 1-3 Remote meterreading application

Application of remote monitoring in oil well

The distribution of oil wells is very wide, so it is impossible to use the wired

communication mode for remote control. After years of development, wireless communication technology has been very mature and widely used in various industries. The function of DTU module has been modularized and standardized.

The wireless monitoring system for oil wells is composed of sensors, wellhead controller, DTU data transmission unit, real time database server, WEB server, and monitoring terminal. The sensors of oil well working state are mainly temperature sensor, pressure

sensor, motor current sensor, voltage sensor of pumping unit load, displacement sensor and transformer primary side current sensor, they will transform the working status into the corresponding voltage or current value and send to the wellhead controller. The well head controller collects the signals of various sensors and gets the working condition of the oil well. The wellhead controller will send the collected signals to the DTU through the serial port, and then the DTU will send it to the remote Internet data center through the wireless network. Its typical application networking is shown as Figure 1 -4.

Figure 1-4 Oilfield application

Integrated application of wireless environmental monitoring

In the environmental monitoring, it is necessary to monitor the pollution emission points,

and most of the monitoring data need to be sent to the back-end server of the

Page 10: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 4

H7000 Series DTU User Manual

management center. Because the monitoring points are scattered, the distribution range

is wide, and most of them are located in the areas with bad environment, it is the best choice for the environmental protection departments to use the wireless network to transmit data. Pollution source monitoring equipment can capture the image, pollution emission data and alarm information, and send to multiple environmental monitoring departments through the wireless network, to achieve timely management of sewage units or individuals, greatly improving the work efficiency of the environmental protection department. Its typical network is shown as Figure 1-5.

Figure 1-5 Environmental monitoring application

Fog system application

Application and construction of environment in fog monitoring system. The H7000 series

DTU two development of the data collection on front nozzle, by PLC (Programmable Logic Controller) to control the front nozzle, while the PLC connection DTU, ultimate access spray system software platform, monitoring and control to achieve the remote equipment running status, maximally solve the inconvenience the hot weather brought factors. Its typical network is shown as Figure 1-6.

Page 11: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 5

H7000 Series DTU User Manual

Figure 1-6 Fog system application

Application of water resources monitoring system

We Hongdian corporation through years of water conservancy industry customer support

and understanding , accumulate a lot of experience, independent research and develop a remote data terminal equipment (hereinafter referred to as RTU). Real time hydrological information acquisition of various modern sensor technology with the equipment, such as rainfall, evaporation, water level (tide, underground water level), flow (velocity, water), water quality, realize the information collection, processing, storage and retrieval function, and the data will be collected real-time information through the wireless communication channel to the management system that is convenient for the user to timely understanding of rainfall, hydrological and other hydrological information. It is characterized by fast, accurate, large amount of information, and can be seamlessly connected with the third party system. Typical application is shown as Figure 1-7.

Page 12: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 6

H7000 Series DTU User Manual

Figure 1-7 Water resources monitoring application

1.3 Equipment accessories and model description

Accessories description

H7000 series DTU includes accessories as shown in table 1-1.

Table 1-1 Accessories list

Name Number Remark

Generally include the following

H7000 series DTU 1 different type with customer order

2G/3G/4G antenna 1 different type with customer order

Certificate and

warranty card

1 empty

+12V power adapter 1 Optional

H7000 series DTU and accessories are using anti-static bag packaging, in order to prevent static electricity caused by different degrees of damage to equipment and accessories.

Use the device specified power adapter (recommended 12VDC 1.5A power adapter)

The equipment should be horizontal or vertical fixed to prevent the equipment from loosing and sliding

Equipment should be placed away from fire, high temperature, direct sunlight

Do not place the equipment in a damp place to prevent the equipment from being stained with various liquids

Page 13: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 7

H7000 Series DTU User Manual

Interface specification

See the technical specifications of various types of products.

1.4 Equipment appearance

Figure 1-8 Housing appearance

Table 1-2 Interface list

Seque

nce

Name Description

❶ Pluggable terminal blocks

spacing: 3.5mm, 12Pin。

User data and power cable recommendations: 14~

24AWG。

H7000 series DTU is provided RS-232/RS-485/RS-422/TTL four user interface, for detailed interface signal definition see H7000 series

DTU technical specification (V2.0).

❷ Status indicator

Used to display the system operation and network, data status.

PWR: On shows that the device is powered normally.

DATA:On shows device restart or local upgrade; flashing shows data transceiver.

NET: flashing shows normal network.

see H7000 series DTU technical specification (V2.0) for more info.

❸ SIM card slot Select the corresponding SIM card according to the type

Page 14: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 8

H7000 Series DTU User Manual

of network supported, unscrew the SIM card cover and insert the SIM card

❹ Antenna

interface

RF coaxial connector, included in the module.

Page 15: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 1

H7000 Series DTU User Manual

2 DTU Installation

Unpacking and inspection accessories are complete. Under normal circumstances, the entire set of equipment should include accessories such as Table 1 -1.

Wiring method refers to the following figure.

Figure 2-1 Wiring method

Page 16: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 1

H7000 Series DTU User Manual

3 Application Guide

3.1 Summary H7000 series DTU is widely used, the following is a typical functional model of H7000 series DTU in the actual application process:

Optimal transmission mode Transparent TCP transmission mode Transparent UDP transmission mode Protocol TCP (TCP+DDP) transmission mode Protocol UDP (UDP+DDP) transmission mode Short message (SMS) transmission mode SMS remote parameter management Wake up mode APN/VPDN network transmission Single / multi center transmission mode Single / double main standby center transmission mode TCP Server (server) mode transmission mode DEMO remote parameter management Remote upgrade software Independent service channel and management channel Unified management of cloud management platform Alarm function

3.2 Optimal transmission mode The parameters of the optimal transmission mode are as shown by 3-1 Table

For other parameters, you can see in the below contents.

Please see the "3.6 UDP+DDP transfer mode (single center") for the configuration inspection.

Table 3-1 Prameters

Parameter Value Remark

Protocol to

DSC

UDP+DDP To ensure the reliability of the channel

under the premise of improving communication efficiency.

Page 17: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 2

H7000 Series DTU User Manual

Parameter Value Remark

DSC IP address

Fixed IP address Avoid domain name update IP address time delay problem.

DSC port DSC server port

Retry interval 60 seconds When the server is in the event of an

abnormal situation in a timely manner to restore the normal channel

connection。

Retry times 3 times When the server is in the event of an

abnormal situation in a timely manner to restore the normal channel connection

Debug information

OFF In normal communication, it needs to be shut down to avoid redundant data in the communication with the lower

computer.

After login DTU Tool successfully, click "More->Login" (default password "admin"), such as Figure 3-1 shows. Configuration parameters such as Figure 3-2, after the legal parameters are configured, the check box in the front of the parameter will be automatically selected, click settings parameters to make the parameter configuration effective.

Page 18: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 3

H7000 Series DTU User Manual

Figure 3-1 DTU tool box login

Figure 3-2 DTU tool-channel1

Page 19: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 4

H7000 Series DTU User Manual

Figure 3-3 DTU tool-running

3.3 Transparent TCP transmission mode (Single center)

Parameter configuration

Transparent TCP transmission channels need to configure parameters such as Table 3 -2,

other parameters maintain the default value.

Table 3-2 Parameters

Parameter Value

Protocol to DSC TCP

DSC IP address Configure the IP address based on the actual DSC.

DSC port Configure the port according to the actual allocated DSC.

After the device login DTU Tool is successful (V5X and V6X through the debug port configuration parameters), click "more" administrator login, enter the administrator login password, the default login password is "admin". Configuration parameters such as Figure 3-4, after the legal parameters are configured, the check box in the front of the parameter will be automatically selected, click settings parameters to make the parameter configuration effective.

Page 20: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 5

H7000 Series DTU User Manual

Figure 3-4 Channel TCP

After setting the parameter configuration, select "More > Restart", restart the DTU device.

Configuration inspection

Step 1 Launch the Socket tool (TCP/IP testing tool) to start the TCP server in your server host(The

PC's IP has been mapped to the public IP, such as 121.37.24.177), then configure your listening port and run the TCP server.

Step 2 Wait a few seconds after DTU and "TCP Test Tool" connection is successful, in the "client" display device connection information. At the same time, on the serial port tool shows the device login successful information, such as Figure 3-5 and Figure 3-6.

Table 3-3 Parameters

Parameter name

Value

Host IP Local host IP, which correspond to TCP server IP.

Port The listening port which correspond to the server IP.

If the IP address for the non public IP, you need to IT your department to do NAT port mapping, or contact our technical staff.

Page 21: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 6

H7000 Series DTU User Manual

Figure 3-5 Open TCP server

Figure 3-6 View DTU debug log

Step 3 After setup the socket connection successful, send data to the TCP server in the serial port

tool, the TCP server display the received data, . on the other hand, the TCP server can also

Page 22: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 7

H7000 Series DTU User Manual

send the data to the DTU displaying via the serial port (make sure the config of the serial

data port of the DTU is correct).

Figure 3-7 Data transmission

3.4 TCP+DDP transmission mode (single center)

Parameter configuration

TCP+DDP transmission channels need to configure parameters such as Table 3 -4, and

other parameters maintain the default value.

Table 3-4 Parameters

Parameter Value

Protocol to DSC TCP+DDP

DSC IP address Configure the IP address based on the actual DSC.

DSC port Configure the port according to the actual allocated DSC.

After the device login DTU Tool is successful, click "more" for administrator login, enter the administrator login password, the default login password is "admin". Configuration parameters such as Figure 3-9, after the legal parameters are configured, the check box in the front of the parameter will be automatically selected, click settings parameters to

make the parameter configuration effective.

Page 23: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 8

H7000 Series DTU User Manual

Figure 3-8 Channel TCP+DDP

After setting the parameter configuration, select More > Restart, restart the DTU device.

Configuration inspection

Step 1 Lunch the wireless data center demo, select "Settings > service, open the service settings

window.

Step 2 Set parameter values as shown in Table 3-5 into the interface shown in Figure 3-10

Table 3-5 Parameters

Parameter

Value

Service

protocol

TCP

Server IP The public IP of your test/debug PC

Server

port

The listening port which correspond to the server IP.

If the IP address for the non public IP, you need to IT your department to do NAT port mapping, or contact our technical staff.

Startup

type

Default value "auto start".

Page 24: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 9

H7000 Series DTU User Manual

Figure 3-9 DSC demo TCP+DDP

Step 3 Click “OK” to return to the main interface of DSC DEMO, click on the upper left corner of the "start button", when the wireless data center demonstration system of Demo and

serial display window respectively such as below figures, DTU has shown the information and successfully registered to the center.

Figure 3-10 Start service

DSC supports to send data the DTU in timing, meanwhile supports the text/hex to send and send in group.

Page 25: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 10

H7000 Series DTU User Manual

Figure 3-11 View DTU debug log

Step 4 Send the data between DTU and the DSC DEMO to test if the parameter configuration and

the network transmission are well.

1. Click the list item under the DTU ID to select the DTU, as below figure, and you can view the "DTU Number" is auto filled in.

Page 26: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 11

H7000 Series DTU User Manual

Figure 3-12 Device connection

2. Input the text message you want to send to DTU in the input field, and click "Send". The message

will be sent to DTU via the TCP+DDP protocol. Conversely, the DSC DEMO can also receive the message which is sent by the DTU. As shown in figures below.

Page 27: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 12

H7000 Series DTU User Manual

Figure 3-13 Send message

Page 28: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 13

H7000 Series DTU User Manual

Figure 3-14 Receive view

3.5 Transparent UDP transmission mode (Single center)

Parameter configuration

Transparent UDP transmission channels need to configure parameters as Table 3 -6, other

parameters to maintain the default value.

DSC must be supported to allow Ping; otherwise there is a risk of communication reliability.

Table 3-6 Parameters

Parameter Value

Protocol to DSC UDP

DSC IP address Configure the IP address based on the actual DSC.

DSC port Configure the port according to the actual allocated DSC.

ICMP detection IP

The default configuration is the DSC address of the IP, can also be configured according to the actual needs of the same LAN IP or domain name address. If the configuration address detection fails, the DSC address of the default IP is detected. Risk reduction of

Page 29: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 14

H7000 Series DTU User Manual

Parameter Value

communication reliability.

Heart beat package interval

If its value is set to over 0, and custom heart beat package is not configured ("Chanel x -> define register package" is null), the ICMP detection will be started.

If its value is set to 0, it will be no ICMP detecting.

After the device login DTU Tool is successful, click "more" administrator login, enter the administrator login password, the default login password i s "admin". Configuration parameters such asbelow figures, after the legal parameters are configured, the check box in the front of the parameter will be automatically selected, and then click set parameters to make the parameter configuration effective.

Figure 3-15 Channel UDP

After setting the parameter configuration, select More > Restart, restart the DTU device.

Configuration inspection

Step 1 Open the serial port tool to view the DTU device debugging information, in the serial port

device to display the device login information, as shown in below figure.

Page 30: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 15

H7000 Series DTU User Manual

Figure 3-16 DTU log view

Step 2 Start the TCP-UDP service management tool, select the "UDP Server" tab, and configure

the parameters shown in the UDP service settings page, such as Table 3-7, and click listen as shown in below figure.

Table 3-7 Parameters

Parameter Value

Host Local host IP, which correspond to UDP server IP.

Port The listening port which correspond to the server IP.

If the IP address for the non public IP, you need to IT your department to do NAT port mapping, or contact our technical staff.

Page 31: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 16

H7000 Series DTU User Manual

Figure 3-17 UDP client

Step 3 Test the data transmission between DTU and the Server

3. Send the message to the server from DTU serial port.

4. Select the client device in the client area of TCP-UDP service management, and fill in the data

transfer area to send the information to the device. 5. Observe the data transceiver in the serial port and UDP Server terminal, view the serial

debugging display log and UDP Server window display information such as the figures below.

Figure 3-18 UDP data transmission

3.6 UDP+DDP transmission mode (single center)

Parameter configuration

UDP+DDP transmission channels need to configure parameters such as Table 3-8, and other parameters maintain the default value.

Page 32: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 17

H7000 Series DTU User Manual

Table 3-8 Parameters

Parameter Value

Protocol to DSC UDP+DDP

DSC IP address Configure the IP address based on the actual DSC.

DSC port Configure the port according to the actual allocated DSC.

After the device login DTU Tool is successful, click "more" administrator login, enter the administrator login password, the default login password is "admin". Configuration parameters such as below figure, after the legal parameters are configured, the check box

in the front of the parameter will be automatically selected, click settings parameters to make the parameter configuration effective.

Figure 3-19 Channel UDP+DDP

After setting the parameter configuration, select More > Restart, restart the DTU device.

Configuration inspection

Step 1 Start wireless data center demo Demo, select "Settings > service, open the service settings window, as shown in below figure.

DEMO tools forced to open the default DDP protocol.

Page 33: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 18

H7000 Series DTU User Manual

Figure 3-20 DSC demo UDP+DDP

Step 2 Set parameter values as shown in Table 3-9 into the interface shown in below figure.

Table 3-9 Parameters

Parameter Value

Service

protocol

UDP

Server IP The public IP of your test/debug PC

Server port The listening port which correspond to the server IP.

If the IP address for the non public IP, you need to IT your department to do NAT port mapping, or contact our technical staff.

Startup type Default value "auto start".

Step 3 In the below figure as shown in the lower right-hand corner of the interface, click OK to

return to the main interface of the wireless data center demo system Demo, click on the upper left corner of the "start button", when the wireless data center demonstration system of Demo and serial display window respectively such as Figure 3-24 and Figure 3-25 Table DTU has shown the information shown successfully registered to the center.

Page 34: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 19

H7000 Series DTU User Manual

Figure 3-21 Start service

Step 4 Send the data between DTU and the DSC DEMO to test if the parameter configuration and

the network transmission are well.

Page 35: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 20

H7000 Series DTU User Manual

6. Click the list item under the DTU ID to select the DTU, as below figure, and you can view the "DTU

Number" is auto filled in.

Figure 3-22 Data transmisstion

7. Input the text message you want to send to DTU in the input field, and click "Send". The message

will be sent to DTU via the TCP+DDP protocol. Conversely, the DSC DEMO can also receive the message which is sent by the DTU, as shown in below figures.

Page 36: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 21

H7000 Series DTU User Manual

Figure 3-23 DTU data view

Figure 3-24 DSC demo data view

Page 37: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 22

H7000 Series DTU User Manual

3.7 Short message (SMS) transmission mode As a supplement of the wireless transmission mode, the short message transmission mode can complete the data transmission of the lower machine when the wireless network is abnormal, and guarantee the integrity of the user data. H7000 series DTU short message transmission mode is divided into two categories: SMS protocol and ordinary SMS; the biggest feature is in 2G, 3G, 4G service the DTU can send and receive text messages (such as managing devices by SMS transmission and SMS protocol), H7000 series DTU's message transmission method has wide applicability, simple application flexible, mainly includes: 2G, 3G, 4G and SMS mutual backup, 2G, 3G, 4G and SMS channel coexistence, wake up, SMS devices management, etc..

Protocol short message: according to the macro power independent development of the short message protocol for remote device parameter management (see 3.8 SMS remote parameter management) and remote wake-up device on the line (see the 3.9 wake-up mode)

Ordinary SMS: Non-protocol messages; mainly through the realization of short message data transmission, is divided into short message channel two-way communication and non text messages via SMS. The biggest feature is not short message channel and 2G, 3G, 4G channel coexist at the same time, the main realization of the SMS call test data (2G, 3G, 4G mode transmission) and other applications (more in water conservancy industry).

SMS channel bidirectional transmission:

SMS mode + channel service number (single / multiple) The lower computer can communicate with the channel service number by ordinary SMS Protocol short message

SMS channel short message transmission:

Any working mode + SMS center number (single / multiple) Short message service center number of the general text messages sent to the lower

machine

Protocol short message service

SMS service center number is configured to 00001, deal with all the number of protocol messages, through all the numbers of ordinary text messages.

The following is a short message channel to achieve the next machine and mobile phone data transfer as an example to introduce the parameter configuration.

Parameter Configuration

You do not need to configure any parameters in the SMS mode by default. However, if you need to send Chinese SMS must be configured for UCS2. DTU short message transmission mode supports the font, so the Chinese text messages are sent in the

use of the s tandard font encoding.

Page 38: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 23

H7000 Series DTU User Manual

Here "channel service number" configuration of a single terminal number, service center number

configured as "00001" as an example to illustrate.

Short message transmission channels need to be configured as shown in the parameters of Table 3-10, other parameters to maintain the default value.

Table 3-10 Parameters

Parameter Value

Protocol to DSC

SMS

Server center

number

Can be set more than one number, in the middle of the

"separation", each number is not more than 32 digits, the maximum can be set to the number of 16.

Encoding mode

Optional values:

7BIT: SMS maximum packet length of 160 bytes (can not send invisible characters)

8BIT: SMS maximum packet length of 140 bytes (can be sent to the invisible character, to support the transfer of the character)

UCS2: SMS maximum packet length of 70 Chinese characters (only in this mode to support the national standard font encoding to send Chinese SMS)

Default value: 8BIT

Channel

service number

Can set more numbers, the maximum can be set 16 numbers, each

number is not more than 32 bytes, each number between the "," separation.

After the device login DTU Tool is successful, click "more" administrator login, enter the administrator login password, the default login password is "admin". Configuration parameters such as Figure 3-29, after the legal parameters are configured, the check box in the front of the parameter will be automatically selected, click “Setup” to make the parameter configuration effective.

Figure 3-25 SMS mode

Page 39: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 24

H7000 Series DTU User Manual

Figure 3-26 Channel SMS

After setting the parameter configuration, select More > Restart, restart the DTU device.

Configuration inspection

In order to facili tate debugging, here will be the parameters of the channel service number configured for the phone number. Here is the phone as DSC.

Through the DTU serial port to send text messages to the phone (in the string input box, enter the characters, click "send"), then the serial tool window displays the message to send a message; meanwhile, the phone also received a text message sent from the DTU device, as shown in below figures.

Figure 3-27 DTU log view

Page 40: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 25

H7000 Series DTU User Manual

Figure 3-28 DTU send Data

Send a text message to the SIM card of the DTU device via the phone. In the serial port tool window it can receive messages sent from the phone, as shown in below figures.

Page 41: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 26

H7000 Series DTU User Manual

Figure 3-29 Phone SMS view

Figure 3-30 DTU receive data

3.8 SMS remote parameter management

SMS parameter management rules

The H7000 series DTU device supports remote configuration of parameters by SMS, which

is convenient for the user to configure the parameters in the remote area without having to configure and maintain the equipment locally. Greatly facilitates the customer operation.

Remote parameter configuration and other operations are a way to send a short message to the SIM card number in the DTU through a mobile phone.

Page 42: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 27

H7000 Series DTU User Manual

In order to confirm the short message parameter, it is necessary to confirm whether the

relevant parameters are configured correctly. For specific configuration strategies, please refer to 3.7 SMS (SMS) transmission.

More information on the way to remotely manage more parameters, please contact the macro technical staff, the following is only a brief introduction of several commonly used remote parameter management.

SMS mode H7000 series DTU for parameter configuration and operation include the following:

Remote parameter configuration

SMS format: < Remote command >:parameter1=PrarmValue,parameter2=PrarmValue,....

For example:

Set:ip1=210.75.17.180,port1=30090,domain1=www.mdtu.com,mode1=tcp,apn=cmnet,user=cmnet,pwd=cmnet, code=*99*,id=123000 The parameter description is shown as Table 3-11.

Table 3-11 Parameters

Parameter

name Meaning

Description

ip DSC IP address Once you can set the DTU to set all parameters of this part.

Among them, IP1, port1, mode1Table shows the parameters for channel 1, and so on.

Multiple parameters are separated by the comma ",".

port DSC port

domain DSC domain

mode Protocol mode to communicate

with DSC

apn Access point name

user Username of APN

pwd Password of APN

code Service code

id DTU id

After setting, according to the actual situation to return to the following two states:

Success:DTU set param successed

Fail:DTU set param failed

Device reset

Device reset message format: XXXXX (5 characters) reset

Transmitting data

Message format of translating data:XXXXXXXXXX (more than 5 characters) data:xxxxxxxx

Page 43: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 28

H7000 Series DTU User Manual

Application examples

Here to configure for UDP+DDP transmission mode, "channel service number" as

"13537780593", "service center number" as "00001", "encoding" as "UCS2" as an example to illustrate.

Step 1 DTU and DSC are connected (UDP+DDP protocol) state, as shown in below figures.

Page 44: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 29

H7000 Series DTU User Manual

Figure 3-31 DTU log view

Figure 3-32 Logon DSC demo

Step 2 Through the channel service number 13537780593 to send DTU SMS (SMS content:

set:ip1=210.75.10.180), mobile phone terminal received from DTU returns after the message is sent successfully,as shown in below figure.

Page 45: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 30

H7000 Series DTU User Manual

If you do not configure any number or service center number is configured to 00001, then any number can be configured for DTU SMS, but it cannot wake up by the phone call.

If there is a "channel service number" or "service center number", only the number of the configuration can be configured for DTU SMS, you can call to wake up DTU.

Figure 3-33 Phone SMS

Step 3 Log on to the DTU Tool to view channel 1 "DSC's IP address 1", and query the results as

shown in Figure 3-38.

Page 46: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 31

H7000 Series DTU User Manual

Figure 3-34 Channel IP

Step 4 Through the mobile terminal to the DTU device to restore the text messages (SMS content

reset), as shown in below figure.

Figure 3-35 Phone SMS

At this time in the serial port to observe the DTU information, DTU system reset, as shown

in below figure.

Page 47: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 32

H7000 Series DTU User Manual

Figure 3-36 DTU log view

3.9 Wake up mode

Parameter configuration

Using the transmission mode is mainly applied to wake up not long time user data

transmission, this scenario can be via SMS / data in a variety of ways (configurable) to wake up the DTU device on the line to save the data flow, and reduce the communication cost to.

The use of wake up transmission data transmission parameters need to be configured as shown in Table 3-12, other parameters to maintain the default value

If you are using a text message to wake up, make sure that the short message sent by the handheld terminal has a short message feature, and the "DSC communication mode" parameter is set to "SMS".

In general, the wake-up mode data transmission is used in combination with the offline mode, this time the need to configure the parameters "offline detection mode" and "offline time". The following will not do referrals.

Page 48: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 33

H7000 Series DTU User Manual

Table 3-12 Prameters

Parameter name

Value Description

Protocol to DSC

Options:

UDP+DDP

TCP+DDP

TCP

UDP

SMS

Any channel can wake up DTU.

DSC IP Configure the IP address based on the actual DSC.

If the DSC communication method is not configured with "SMS", you need to configure.

DSC port Configure the port according to

the actual allocated DSC.

Channel on-line mode

Configured as WAKE Must be configured as "WAKE".

IP channel

wake-up mode

Options:

SMS

CALL

DATA

SMS+CALL

SMS+DATA

DATA+CALL

SMS+DATA+CALL

Can be configured for either

option.

Channel service number

Can set a number, the maximum can be set up 16 numbers, each number is not more than 32 bytes, and the numbers are separated by the comma ",".

Channel service number / service center number two parameters can be configured for any one.

Each parameter can be configured up to 16 numbers, each number is not more than 32 bytes, and the numbers are separated by the comma ",".

Service

center number

Can set multi numbers, the

maximum can be set 16 numbers, each number is not more than 32 bytes, the numbers are separated by the comma ",".

After the DTU Tool connect to the DTU device successfully, click "More->Login" to input the administrator login password, the default login password is "admin". Configuration parameters such as Figure 3-41, Figure 3-42, Figure 3-43,the parameters of the check box

in the front will be automatically selected, click the "Setup" button to configure the parameters into effect.

Page 49: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 34

H7000 Series DTU User Manual

Figure 3-37 SMS mode

Figure 3-38 Running wake mode

Page 50: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 35

H7000 Series DTU User Manual

Figure 3-39 Channel

After setting the parameter configuration, select More > Restart, restart the DTU device.

Configuration inspection

Wake up DTU data by wake up mode

Step 1 Make sure that the DTU device can connect to the data center(DSC DEMO) .

Step 2 Simulate RTU to send data to the DTU device in the serial port, wake up DTU, see below figures.

Page 51: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 36

H7000 Series DTU User Manual

Figure 3-40 DTU log view

Figure 3-41 DTU log checking

Figure 3-42 DSC data transmission

Page 52: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 37

H7000 Series DTU User Manual

Phone call wake up

Through the channel of arbitrary configuration service number / service center number "two parameters in a mobile phone number to dial DTU equipment in the SIM card number, while observing the message serial, when found the following information, Table telephone call wake-up mode has awakened DTU equipment.

[00:10:03] number matching, ready to line up / / matching number

[00:10:37] channel [0] send 22 bytes / / has to wake up DTU, data communication

[00:10:37] channel [0] receives 16 bytes

[00:10:37] channel [0] login successful

[00:11:17] channel [0] sends 22 bytes

[00:11:17] channel [0] receives 16 bytes

[00:11:17] channel [0] handles DDP packages [0x81]

[00:11:49] signal value: 29

[00:11:57] channel [0] sends 22 bytes

[00:11:57] channel [0] receives 16 bytes

[00:11:57] channel [0] handles DDP packages [0x81]

[00:12:37] channel [0] sends 22 bytes

[00:12:37] channel [0] receives 16 bytes

[00:12:37] channel [0] handles DDP packages [0x81]

[00:13:17] channel [0] sends 22 bytes

[00:13:17] channel [0] receives 16 bytes

[00:13:17] channel [0] handles DDP packages [0x81]

[00:13:57] channel [0] sends 22 bytes

[00:13:57] channel [0] receives 16 bytes

[00:13:57] channel [0] handles DDP packages [0x81]

SMS wake up

SMS wake up validation process see "3.8 SMS remote parameter management"。

Page 53: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 38

H7000 Series DTU User Manual

3.10 APN/VPDN network transmission In the use of APN/VPDN private network transmission mode, the other parameters of the configuration method with other transmission methods (such as TCP transmission, UDP transmission, TCP+DDP, UDP+DDP). For other parameters, see the configuration of the parameters in the related transport method.

However, special attention should be paid to the configuration of mobile service parameters such as Table 3-13, as shown in Figure 3-46, Figure 3-47 and Figure 3-48.

If the following parameters are configured to correspond to the parameters of the network's public network or to save the system's default parameters, the system is adapted according to the network.

Table 3-13 Parameters

Network

Parameter name

Value

China Mobile

APN China Mobile network access points, such as CMWAP or CMNET.

Service code *99***1#

Username User name for network accessed, such as "username".

No configuration is required by default.

Password Password for network accessed, such as "password".

No configuration is required by default.

China

Unicom

APN China Unicom network access point, such as "uniwap".

Service code *99#

China Telecom

APN China Telecom network access point, such as "CTNET".

Username Provided by telecom operators, it is necessary to apply

to the local telecom business office. For example: [email protected]

Password Provided by telecom operators, it is necessary to apply to the local telecom business office. For example:

vnet.mobi

Service code #777

Page 54: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 39

H7000 Series DTU User Manual

Figure 3-43 SIM config 1

Figure 3-44 SIM config 2

Page 55: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 40

H7000 Series DTU User Manual

Figure 3-45 SIM config 3

3.11 Multi center transmission mode

Parameter configuration

Multi center transmission mode is DTU and a number of data centers (the system

currently supports up to four data centers at the same time) data transmission.

If other channels are not in use, be sure to clear the parameters of other channels to prevent waste flow.

Multi center transmission mode can be mixed with a variety of protocols, for example,

DDP+UDP, TCP transparent, SMS and other hybrid applications. The method of configuration and verification of main and standby mode, please refer to "3.12 main and backup center transmission mode".

Here take an example for illustration to make DTU connects to two centers (channel 1 set to "TCP+DDP", channel 2 set to "UDP+DDP") via 2G, 3G, 4G network (the public mapping ports of the two centers are respectively 51663 and 51662). Parameter settings see below Table 3-14:

Page 56: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 41

H7000 Series DTU User Manual

Table 3-14 Parameters

Parameter name Value

Running mode MUL

Protocol to DSC 1 TCP+DDP

DSC IP 1 Configure the IP address based on the actual DSC.

DSC port 1 Here set to 51663 which is the public port after our NAT

mapping.

Protocol to DSC 2 UDP+DDP

DSC IP 2 Configure the IP address based on the actual DSC.

DSC port 2 Here set to 51662 which is the public port after our NAT mapping.

The configuration of the parameters is shown in Figure 3-49, Figure 3-50 and Figure 3-51. Check the check box of the configured parameters, and Click "Set parameters" after the configuration completing.

Page 57: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 42

H7000 Series DTU User Manual

Figure 3-46 Running mode

Figure 3-47 Channel1 mode

Figure 3-48 Channel 2 mode

Page 58: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 43

H7000 Series DTU User Manual

Click “Setup” to save and select "More> Reboot DTU" to restart the DTU a fter setting the

parameters.

Configuration inspection

Step 1 Start two wireless data center demo Demo (name them as "DSC1" and "DSC2"), select "Settings> Services", open the service settings window.

Step 2 Set the parameter values shown in Table 3-15 as shown in Figure 3-52 and Figure 3-53.Click "OK" to save, and start the DSC services.

Table 3-15 Parameters

DSC

name

Parameter

name

Value

DSC1 Service protocol

TCP

Server IP The public IP of your test/debug PC

Server port The listening port which correspond to the server IP.

If the IP address for the non public IP, you need to IT your department to do NAT port mapping, or contact

our technical staff

Startup type Default value "auto start"

DSC2 Service protocol

UDP

Server IP The public IP of your test/debug PC

Page 59: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 44

H7000 Series DTU User Manual

DSC

name

Parameter

name

Value

Server port The listening port which correspond to the server IP.

If the IP address for the non public IP, you need to IT your department to do NAT port mapping, or contact

our technical staff

Startup type Default value "auto start"

Figure 3-49 DSC 1 config

Page 60: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 45

H7000 Series DTU User Manual

Figure 3-50 DSC 2 config

Step 3 DSC2 configTurn to serial port tool to view the DTU log showing the info such as “UDP+DDP mode login success” or “TCP+DDP mode login success”,etc.

Step 4 At the same time, DSC1 and DSC2 show the registered device list in the main interface, means that the connection has established.Thus, the DTU device connects to two DSC,

and can communicate with the two DSC at the same time.

3.12 Main standby center transmission mode

Parameter configuration

The main production center transmission mode is divided into two types of single and

double standby transmission. The main standby center type is flexible in application. Generally, channel 1 and channel 2 are the main channels; channel 3 and channel 4 respectively are the backup channels of channel 1 and 2. In normal use, the short message channel can also be used as a standby channel. Here make an example for the double

main transmission mode as illustrated in the Table 3-16.

Table 3-16 Parameters

Channel type

Parameter name Value

-- Running mode MULB

Channel 1

(main)

Protocol to DSC 1 TCP+DDP

DSC IP address 1 Configure the IP address based on the actual

DSC; can be obtained from the DSC side

Page 61: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 46

H7000 Series DTU User Manual

Channel

type

Parameter name Value

DSC port 1 Here set to 51663 which is the public port after our NAT mapping.

Channel

3 (standby)

Protocol to DSC 3 SMS

Service center number

The maximum can be set 16 numbers, separated by the comma ","; each number does not exceed the number of 32 strings.

Encoding mode Optional values:

7BIT: SMS maximum packet length is 160 bytes 8BIT: SMS maximum packet length is 140 bytes UCS2: SMS maximum packet length of 70 Chinese

characters

Default value: 8BIT

Configured as UCS2

Channel service

number

The maximum can be set 16 numbers, separated

by the comma ","

Channel 2

(main)

Protocol to DSC 2 UDP+DDP

DSC IP address 2 Configure the IP address based on the actual

DSC; can be obtained from the DSC side

DSC port 2 Here set to 51662 which is the public port after our NAT mapping.

Channel

4 (standby)

Protocol to DSC 4 TCP

DSC IP address 4 Configure the IP address based on the actual DSC; can be obtained from the DSC side

DSC port 4 Here set to 51661 which is the public port after our NAT mapping.

Parameter configuration as shown in Figure 3-61, Figure 3-62, Figure 3-62 and Figure 3-64 below, the check box will be automatically selected when you configure the value, after setting complete click "set parameters" to take effect.

Page 62: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 47

H7000 Series DTU User Manual

Figure 3-51 Running mode

Figure 3-52 Channel 1 mode

Page 63: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 48

H7000 Series DTU User Manual

Figure 3-53 Channel 3 mode

Figure 3-54 SMS checking

Figure 3-55 Channel 2 mode

Page 64: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 49

H7000 Series DTU User Manual

Figure 3-56 Channel 4 mode

After setting the parameter configuration, select More > Restart, restart the DTU device.

Configuration inspection

Step 1 Lunch the two DSC DEMO (as Master-DSC1 and Master-DSC2) and select the "Settings >

service", open service settings window and set up service parameters, as shown in Figure 3-67 and Figure 3-68, and parameters is illustrated in Table 3-17.

Table 3-17 Parameters

DSC name Parameter name

Value

DSC1 Service type TCP+UDP

Page 65: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 50

H7000 Series DTU User Manual

DSC name Parameter

name

Value

Specify IP The public IP of your test/debug PC

Service port The listening port which correspond to the server IP.

If the IP address for the non public IP, you need to IT your department to do NAT port mapping, or contact our technical staff.

Startup type Default value "auto start".

DSC2 Service type UDP+DDP

Specify IP The public IP of your test/debug PC

Service port The listening port which correspond to the server IP.

If the IP address for the non public IP, you need to IT your department to do NAT port mapping, or contact our technical staff.

Startup type Default value "auto start".

Page 66: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 51

H7000 Series DTU User Manual

Figure 3-57 DSC 1

Figure 3-58 DSC 2

Step 2 Open the "TCP Test Tool" (Slave-DSC2), set the TCP Server service settings as shown in below figure.

Page 67: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 52

H7000 Series DTU User Manual

Figure 3-59 TCP server

Step 3 In the above figures respectively click "OK", when the interface of the DSC DEMO display

the device,it means that the DTU has been successfully registered Master-DSC1 and Master-DSC2. And you can also view the log in the serial port tool for the login information.Here the DTU can send data to the both of the DSC1 and DSC2, for example, we input “Hello123” to the DTU and send, both DSC1 and DSC2 will receive the data “Hello123”.

Step 4 Stop the Master-DSC1 and Master-DSC2 services (click “Control ->Stop service” or enter “Start Task Manager” in your PC to “End Task”).The DTU will lost the connection to the Master-DSC1 and 2, and turn to register to the back up data service center Slave -DSC1 and Slave-DSC2, wherein the Slave-DSC1 is SMS and the Slave-DSC2 is TCP server by above configuration. For example,If we input the data to the DTU and send, when detect the

Master-DSC1 connection fail, the DTU turn to send data to Slave-DSC1;when detect the Master-DSC2 connection fail, turn to send data to Slave-DSC2.

Step 5 Stop the Slave-DSC1 process, restart the data center Master-DSC1 and Master-DSC2. The DTU will reconnect to Master-DSC1 and Master-DSC2, and the data of the DTU will be sent to the both of Master-DSC1 and Master-DSC2

3.13 TCP Server (server) mode transmission mode

Parameter configuration

TCP Server mode transmission means that the DTU device acts as a TCP server. Before

using this mode of communication, it is necessary to configure the parameters as shown in Table 3-18, and other parameters remain the default values.

Table 3-18 Parameters

Parameter Value

Protocol to DSC TCP_SER

DTU local binding port 4002

Access point Client and server must be configured as the

same network, the same network access

Page 68: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 53

H7000 Series DTU User Manual

Parameter Value

point. For example, both the client and the server are configured as mobile "CMNET" or "CTNET"".

Access username Configure the access point user name provided by the operator.

Access password Configure the access point password provided

by the operator.

Configuration verification

Step 1 Refer to the Table 3-18 configure the DTU parameters, and then restart the DTU device;

Step 2 Turn to serial port tool to view the DTU log showing the running info about the TCP server mode.

Step 3 Open a TCP client which can access the IP of the DTU server,the TCP client can be your smart phone APP or another DTU device, the SIM cards of which should be in the same operator network with the server DTU. Here we take another DTU for TCP client.

Step 4 Configure client DTU device parameters.

Step 5 Configure the following parameters on the client DTU device through the DTU tool box:

DSC IP address: Step 1 to get the server IP value (10.111.33.5) DSC port: port number obtained in step 1 (4002) Communication: TCP Access point: the name of the access point provided by the operator supported by the client

SIM card Access user name: the user name provided by the client SIM card Access password: user password provided by the client SIM card

Step 6 (Generally, wireless network access parameters for the server and client are pro vided for

the same operator).

Step 7 Save parameters, restart client DTU.

Step 8 View the client and server corresponding to the serial display information

Step 9 In the client DTU send test data through the serial port to the server device , the server can receive data from the client.They can communicate with each other.

3.14 DSC remote parameter management DSC remote parameter management is to configure the DTU parameter through the data

center(DSC Demo) . At present, the system can support transparent mode and TCP+DDP, UDP+DDP protocol for remote query and parameter settings, etc..

Below we use the UDP+DDP protocol to connect DTU and the DSC Demo for remote parameter configuration, for more information, please contact the Hongdian technical support engineer.

Step 1 Select "Operation -> Configuration“ in DSC Demo, open the remote parameter settings window, as shown in below figures.

Page 69: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 54

H7000 Series DTU User Manual

Figure 3-60 Remote config via DCS

Figure 3-61 Select DTU

Step 2 After changing the configuration of the DTU, click “Setting” button to set the parameters according to the interface prompts.

Batch settings can also set the parameters for multiple DTU connected to the center.

Step 3 After the parameter configuration is complete, click “Restart” to restart the DTU device.

Page 70: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 55

H7000 Series DTU User Manual

Step 4 Open the DTU tool to get the parameter of the DTU device to view the change.

Figure 3-62 Get parameter

3.15 Remote upgrade software Currently DTU supports UDP+DDP, TCP+DDP, SMS and TCP transparent way, UDP transparent way for remote upgrade program.

Here take UDP+DDP or TCP+DDP as an example to introduce; for SMS mode, TCP transparent mode and UDP transparent mode, the upgrade operation is more complex, if necessary, please contact our technical support engineers to assist.

Prerequisite

The DTU has connected to the data center(DSC_Demo) in UDP+DDP or TCP+DDP mode See "3.4 TCP+DDP transfer mode" and "3.6 UDP+DDP transmission mode" for reference. Prepared a FTP server for storing the DTU upgrade fi le, and the FTP server can be accessed The upgrade fi le has been uploaded to the FTP server, and the name of the fi le name is

modified for upgrade fi le naming requirement.

App type of program upgrade file name must be modified to h7710, otherwise the upgrade can not be identified.

Here UDP+DDP protocol to upgrade the h7710 file as an example to illustrate.

Operation steps

Step 1 In DSC Demo select "DTU Management > FTP remote upgrade", open the remote upgrade

interface.

Step 2 Configure parameters related to the remote upgrade interface.

Page 71: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 56

H7000 Series DTU User Manual

Step 3 Click upgrade, while observing the serial display information, the device to restart

successfully, the upgrade is completed.

3.16 Independent service channel and management channel Independent service channels and management channels are as shown in below figure.

Figure 3-63 Independent service channel

Management channel does not do any forwarding of business data, is responsible for the unified management and control of DTU.

The brief description of the configuration parameters for the independent service channel

and the management channel, as shown in Table 3-19, is of particular concern as shown in the parameter configurations such as below figures.

Table 3-19 Parameters

Channel Description Remark

Running mode

MUL Multi channel mode. One channel is used as a service channel and

the other is used as a management channel.

Channel 1

The basic parameters are consistent with other transmission modes (such as TCP transmission mode, UDP transmission mode, TCP+DDP, UDP+DDP, etc.).

Used as a service channel

Channel

2

The communication mode with DSC is

configured as UDP+DDP

Use as a management

channel.

The data flow control flag is configured as

Page 72: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 57

H7000 Series DTU User Manual

Channel Description Remark

NONE

Other parameters and other modes of transmission (such as TCP transmission

Page 73: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 58

H7000 Series DTU User Manual

Figure 3-64 Running mode

Figure 3-65 Channel 1 mode

Figure 3-66 Channel 2 mode

Page 74: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 59

H7000 Series DTU User Manual

3.17 Cloud management platform for DTU At present, DTU is supported by a unified access management cloud management platform, through the cloud management platform, can be remote upgrade, configuration and maintenance management of our products, can realize the real-time monitoring of the equipment on the spot signal intensity, the base station cell value, packet loss and delay, network communication status etc.. Through the cloud management platform can achieve remote centralized management of equipment, greatly reducing the cost of on-site maintenance.

Cloud management platform for detailed operation, please refer to the user manual cloud management platform.

3.17.1 DTU access cloud platform

Step 1 Configure mobile service parameters. Refer to "3.10 APN/VPDN private network transmission mode"

Step 2 Cloud management platform

You can configure the parameters of the cloud management platform in two ways: Configure by AT command

8. Use the AT extension to empty the terminal sequence number.

AT+LOGIN=Admin// Log in to AT mode

OK

[00:00:13]modem-->>open the device(/dev/ttyS1) succeed

Page 75: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 60

H7000 Series DTU User Manual

[00:00:13]9 <<< (ATE0

)

AT+SETPARAM=WPM2MSN,// Set the terminal serial number empty

OK

[00:00:15]9 <<< (ATE0

)

[00:00:17]9 <<< (ATE0

)

AT+SAVEPARAM// Save parameters

[00:00:19]9 <<< (ATE0

)

[00:00:21]9 <<< (ATE0

)

OK

9. Refer to 1, the use of AT extension instructions for cloud management platform parameters

and serial number configuration, save parameters and restart the device with AT+RESET command.

Table 3-20 Parameters

Paramet

er

Example of AT command Description

M2M platform domain address

AT+SETPARAM=WPDOMAIN,mdtu.com

Domain of cloud management platform.

When connect to the cloud management platform, the domain name address and platform IP

address two can be configured, if the two have a configuration, the system will first select the domain name address to connect.

M2M

platform IP address

AT+SETPARAM=WPIPADDR,2

7.19.34.39

Configure the IP

address of the cloud management platform.

M2M

platform port

AT+SETPARAM=WPDESTPORT

,52471

Configure the port corresponding to

the cloud management platform.

Serial number

AT+SETPARAM=SPPID,7710C201308SG12008

Configure device serial number.

Through the integration of tool box for configuration

1. Log on to the DTU device integration tool box, please refer to "3.2 best transfer mode".

2. Administrator login, select the "management platform" parameters, with reference to the

Table 3-20 set the appropriate management platform parameters, such as below figures. 3.

4. When you configure all parameters, click set parameters to complete the parameter settings.

Page 76: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 61

H7000 Series DTU User Manual

Figure 3-67 M2M platform prameter

5. Click "more" to restart DTU to set the parameters.

Step 3 Log on to the cloud management platform to see if there is a current device in device monitoring > column Table see Figure. If so, the Table device is connected to the cloud management platform, as shown below figure.

Figure 3-68 M2M cloud platform view

3.17.2 DTU parameter query

Step 1 Refer to the "3.17.1" login cloud platform.

Step 2 Select the DTU device to connect to the platform, select the "task" parameter settings.

Step 3 To the right of the input box to enter the query command, click the "query" button can query parameters. AT+GETPARAM? \r\n instruction Table shows all parameters.

Page 77: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 62

H7000 Series DTU User Manual

Figure 3-69 DTU parameter query serial display

3.17.3 DTU parameter setting

Step 1 Refer to the "3.17.1" login cloud platform.

Step 2 Select the DTU device to connect to the platform, select the "task" parameter settings.

Step 3 To the right of the input box to enter the parameters set instructions, click the "OK" button to set the parameters. In this paper, "AT+SETCHL=2\r\nAT+SETPARAM=CHPCT, UDP\r\nAT+SAVEPARAM\r\n (set channel 2 DSC communication and save parameters)

Note: parameter settings need to save parameters , no AT+SAVEPARAM, the data will not be saved.

Note: H7000-V6X DTU does not support cloud management platform through AT configuration and query DTU parameters.

3.18 Alarm function (Optional)

3.18.1 Function introduction

In order to improve the monitoring of the business site and prevent non maintenance personnel illegal destruction of equipment or open the instrument box instrument Table data tampering, customer requirements DTU system support when the passive switch output changes provided by the user, DTU terminal equipment will alarm according to the

change information of different switch.

This function is only implemented in the extended parameter 1, which supports the configuration of a

package.

3.18.2 Alarm mode

The system currently supports the alarm modes:

SMS alarm: SMS messages will be sent to the specified mobile phone number (CDMA

devices only support UCS2 format SMS) Data channel alarm: through the data channel to send alarm information to the DSC, can

support single channel / multi -channel transmission The channel is specified by the user.

Page 78: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 63

H7000 Series DTU User Manual

3.18.3 Trigger mode

The system currently supports two triggers:

GPIO trigger

The trigger data support string and sixteen hex and sixteen hex character configuration, can not be mixed

The system can provide 2 TTL level input pins to the lower computer The system can detect the level 2 input pins, when 3.3 -->0V or 0V / 3.3V jump jump, jump

after stable time to achieve effective time (time range can be set to 400~3000ms), is considered a legitimate jump, otherwise considered jitter, does not produce alarm information.

V3X and V50 (V6X reference V5X) pin level range contrast as shown in Table 3 -21.

Table 3-21 Parameters

User pin

number

Signal

direction

V30 level range V31 level range V32 level range V50 (V50_DS) level range

4

pin

Inpu

t&output

Low input

=0~0.8V

High

input=6~12V

Low

output=0~0.4V

High

output=2.8~3.3V

Low

input=0~0.8V

High

input=2~5V

High

input=0~0.4V

High

output=2.8~3.3V

Low

input=0~0.8V

High

input=2~5V

High

input=0~0.4V

High

output=2.8~3.3V

Low input=0~0.8V

High input=2~5V

High input=0~0.4V

High output=2.8~3.3V

6 pin

Input&output

Low

input=0~0.8V

High

input=2~5V

High

input=0~0.4V

High

output=2.8~3.3V

Low

input=0~0.8V

High

input=2~5V

High

input=0~0.4V

High

output=2.8~3.3V

Low

input=0~0.8V

High

input=2~5V

High

input=0~0.4V

High

output=2.8~3.3V

Low input=0~0.8V

High input=2~5V

High input=0~0.4V

High output=2.8~3.3V

9

pin

Out

put

High

input=0~0.4V

High

output=2.8~3.3V

High

input=0~0.4V

High

output=2.8~3.3V

High

input=0~0.4V

High

output=2.8~3.3V

High input=0~0.4V

High output=2.8~3.3V

Page 79: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 64

H7000 Series DTU User Manual

Note: the current GPIO trigger to achieve 2 GPIO and the combination of the 2 levels of jump mode.

3.18.4 Parameter setting format

For different alarm and trigger mode, the system has made the following definition:

Extended parameter format definition

Table 3-22 Format

Format symbol

Description

<> Represents a configuration package

fnt Function keyword

; Keyword separator

= Keyword voluation

Parameter description

Table 3-23 Parameters

Param

eter

Meaning Optional value Required /

optional

fnt Function keyword alarm Required

trg Trigger mode keyword cmd

gpio

Required

rpt Alarm mode keyword gprs

sms

Required

cmd Trigger command content.

Only support trg=cmd configuration package.

Support sixteen hexadecimal form (starting

must be 0x or 0X), string form.

Required

io Trigger pin.

Only support trg=gpio configuration package.

4,6 Required

jmp Pin triggered level jump mode.

Only support trg=gpio configuration package.

up

down

Required

vld Time hopping stable level.

Only support trg=gpio configuration package.

Range: 4 ~ 30

Unit: 100ms

Required

Page 80: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 65

H7000 Series DTU User Manual

Param

eter

Meaning Optional value Required /

optional

send Alarm content. Support sixteen binary form (must be 0x or 0X), string form.

Required

nums Alarm destination

number group.

Only support gpt=sms

configuration package。

Support 1 ~ 16 numbers,

the length of each number range from 1 to 32 bytes.

Required

chl Alarm destination

number.

Only support rpt=gprs configuration package.

Range: 0 ~ 4.

0 represents all channels.

Required

recv Alarm receipt.

Only support rpt=gprs configuration package.

Support sixteen binary

form (must be 0x or 0X), string form.

Optional

spc Alarm time interval.

Only support rpt=gprs configuration package.

Range: 1 ~ 65535

Unit: seconds (s)

Optional

tms Alarm number.

Only support rpt=gprs configuration package.

Range: 1 ~ 1024

Unit: time

Optional

Note: optional parameters are used to implement additional re-transmissions for extended parameters . Must be configured at the same time, indispensable.

In the parameter configuration, the following points should be noted, otherwise the configuration fails.

Assignment of any key must be within the scope of assignment. A configuration package, any key cannot be repeated.

The length of the configuration format character and the assignment character cannot be greater than 512 bytes.

Key words indicate the scope of the support can not appear in the non support configuration package (for example: only supports the trigger is the GPIO trigger parameters, it can not be set to trigger CMD trigger configuration).

Configuration example

<fnt=alarm;trg=cmd;rpt=gprs;cmd=0x313233;send=123;recv=321;spc=10;tms=5;chl=

1>

<fnt=alarm;trg=cmd;rpt=sms;cmd=0x313233;send=123;nums=13512345678,13312345678>

<fnt=alarm;trg=gpio;rpt=gprs;io=4;jmp=up;vld=4;send=123;recv=321;spc=10;tms=5;chl=1>

Page 81: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 66

H7000 Series DTU User Manual

<fnt=alarm;trg= gpio;rpt=sms;

io=4;jmp=up;vld=4;send=123;nums=13512345678,13312345678>

Configuration verification

SMS verification

Step 1 Configure mobile service parameters. Refer to "2.10 APN/VPDN private network transmission mode".

Step 2 Open the serial port tool, the use of AT extension instruction for the expansion of the parameters of the SMS configuration.

Manufacturer name: Shenzhen electric power technology Limited by Share Ltd

Item number: H7710 GPRS DTU

Software version: V5.0.7-13/10/29-2013/10/29

[00:00:06]system-->>proc extern AT status

AT

OK // Switch to AT mode

[00:00:13]modem-->>open the device(/dev/ttyS1) succeed

[00:00:13]9 <<< (ATE0

)

AT+LOGIN=Admin

OK // Log on AT mode successfully

[00:00:23]modem-->>open the device(/dev/ttyS1) succeed

[00:00:23]9 <<< (ATE0

)

[00:00:23]modem-->>9 >> (ATE0

OK

)

[00:00:23]Modem speed check success 115200

AT+SETPARAM=OPPEXT1,<fnt=alarm;trg=cmd;rpt=sms;cmd=0x313233;send=123;nums=13537780593>

[00:00:25]in param_special_str_to_value

[00:00:25]in check_extend_param

[00:00:25]in check_ext_config_packet

[00:00:25]in check_alarm_config_params

[00:00:25]in get_send_num_by_param

[00:00:25]num pool:13537780593>

[00:00:25]get num:13537780593 num_cnt:1, exit

[00:00:25]in is_param_all_ready

OK // Configure SMS to send alarm parameters successfully

AT+SAVEPARAM

[00:00:31]Local heartbeat once,fd=8...

OK // Save parameters successfully

AT+RESET //Reboot system now

Manufacturer name: Shenzhen electric power technology Limited by Share Ltd

Item number: H7710 GPRS DTU

Software version: V5.0.7-13/10/29-2013/10/29

Page 82: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 67

H7000 Series DTU User Manual

[00:00:07]system-->>start init dtu base envirements ...

[00:00:07]Init share mem ok,0x8178e000

[00:00:07]system-->>init dtu base envirements success ...

[00:00:07]Work mode [Multi-channel], channel nums = 2

[00:00:07]SERIAL_THREAD BEGIN

[00:00:07]system-->>create sms comm task thread ...

[00:00:07]ftp-->>proc update, check files in update dir /usr/dtu/upgrade/temp

[00:00:07]Start detecting module...

[00:00:07]modem-->>open the device(/dev/ttyS1) succeed

[00:00:07]9 <<< (ATE0

)

[00:00:09]9 <<< (ATE0

)

[00:00:11]9 <<< (ATE0

)

Step 3 According to the configuration parameters in the extended serial tool "string input box" input test command "0x313233", click "send", observe the mobile phone, mobile phone will receive content information as SMS alarm information 123 ". As shown in below figures.

Figure 3-70 Phone SMS

Data channel alarm verification

Here only in the TCP+DDP protocol data channel alarm as an example to illustrate.

Page 83: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 68

H7000 Series DTU User Manual

Step 4 Configure mobile service parameters by referring to "3.10 APN/VPDN private network

transmission mode". Using the DTU Tool to configure the channel parameters, refer to the "3.4 TCP+DDP transmission mode (single center)". Reboot after configuration DTU.

Step 5 Open the serial port tool, the use of the AT extension of the terminal sequence number will be empty.

Manufacturer name: Shenzhen electric power technology Limited by Share Ltd

Item number: H7710 GPRS DTU

Software version: V5.0.7-13/10/29-2013/10/29

[00:00:06]system-->>proc extern AT status

AT //Switch to AT status

OK

AT+LOGIN=Admin //login AT command

OK

[00:00:13]modem-->>open the device(/dev/ttyS1) succeed

[00:00:13]9 <<< (ATE0

)

[00:00:15]9 <<< (ATE0

)

[00:00:17]9 <<< (ATE0

)

[00:00:19]9 <<< (ATE0

)

[00:00:21]9 <<< (ATE0

)

AT+SETPARAM=OPPEXT1,<fnt=alarm;trg=cmd;rpt=gprs;cmd=123456;send=123;recv=321;spc=10;tms=5;chl=1> / / set

to channel alarm through GPRS for channel 1

[00:00:22]in param_special_str_to_value

[00:00:22]in check_extend_param

[00:00:22]in check_ext_config_packet

[00:00:22]in check_alarm_config_params

[00:00:22]in is_param_all_ready

OK

[00:00:23]modem-->>open the device(/dev/ttyS1) succeed

[00:00:23]9 <<< (ATE0

)

[00:00:23]modem-->>9 >> (ATE0

OK

)

[00:00:23]Modem speed check success 115200

AT+SAVEPARAM //Save parameter settings

[00:00:31]Local heartbeat once,fd=8...

OK

AT+RESET //Reboot device

Manufacturer name: Shenzhen electric power technology Limited by Share Ltd

Item number: H7710 GPRS DTU

Software version: V5.0.7-13/10/29-2013/10/29

[00:00:07]system-->>start init dtu base envirements ...

Page 84: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 69

H7000 Series DTU User Manual

[00:00:07]Init share mem ok,0x8178e000

[00:00:07]system-->>init dtu base envirements success ...

[00:00:07]SERIAL_THREAD BEGIN

[00:00:07]Work mode [Multi-channel], channel nums = 1

[00:00:07]system-->>create sms comm task thread ...

[00:00:07]ftp-->>proc update, check files in update dir /usr/dtu/upgrade/temp

[00:00:07]Start detecting module...

[00:00:07]modem-->>open the device(/dev/ttyS1) succeed

[00:00:07]9 <<< (ATE0

)

[00:00:09]9 <<< (ATE0

Step 6 Refer to the "3.4 TCP+DDP transmission mode (single center)" to carry out the relevant

configuration and connection.

To enter the test command "123456" in the string input box of the serial port tool, click “send".

Observe DSC Demo and serial port information. Table shows channel data alarm success.

Level data channel alarm verification

Step 7 The verification process of the level data channel alarm is the same as the "B data channel alarm verification", but in the expansion parameter configuration, it is necessary to strictly follow the protocol level alarm configuration format.

Step 8 For example:

<fnt=alarm;trg=gpio;rpt=sms;io=4;jmp=up;vld=4;send=123;nums=13512345678

,13312345678>

Page 85: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 1

H7000 Series DTU User Manual

4 FAQ

4.1 H7000 series DTU is unable to communicate with external devices

Symptom

H7000 series DTU is unable to communicate with external devices.

Failure cause

The causes of the failure are as follows:

The area where the device is unable to provide 2G, 3G, 4G services, 2G, 3G, 4G services are not fully covered in the region, "DSC's IP address" and "DSC port" configuration is not correct

Solution

If the area where the device is unable to provide 2G, 3G, 4G services, 2G, 3G, 4G services are not fully covered by the region,

Please contact the network operator for a reasonable solution. If the "DSC's IP address" and "DSC port" are not configured correctly, configure the

parameters "DSC's IP address" and "DSC".

4.2 Unable to connect to the tool using the DTU Tool configuration parameters

Symptom

PC is unable to connect to the tool when configuring the parameters.

Failure cause

The causes of the failure are as follows:

The computer serial port connected to the device is not working properly. The H7000 terminal is not in the same place as the configuration computer.

Page 86: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 2

H7000 Series DTU User Manual

The time of "RTU connection timeout" of the tool box parameter is shorter.

Solution

If it is connected to the serial port of the PC machine is relatively fragile, serial port can not

work, please replace the PC machine or replace the serial Export. The computer serial port connected with the device can not work normally, and the

connection line between the connecting device and the PC machine is detected. If the H7000 terminal is not in the same place as the PC, please make sure that the ground is

in the same place. If it is a short time on the management tool, the connection device parameter RTU

connection timeout (default is 50 seconds), To modify it for a longer period of time, it is generally recommended to change to 60

seconds. DTU system start-up time of about 18 seconds, after the start of the device will consume a

second time for the detection of the serial port of 10 consecutive spaces. If the test is successful, it will switch to the AT state. Otherwise run the application directly. The device also needs some time to switch to AT.

4.3 DTU send text messages to the phone display garbled

Symptom

DTU send text messages to the phone display garbled.

Failure cause

The reason is that the DTU message encoding format configuration error, configured as

"7BIT".

Solution

Configure DTU SMS short message sending code for "8BIT" or "UCS2".

4.4 DTU cannot resolve DSC domain name

Symptom

DTU cannot resolve DSC domain name, log information is as follows:

00:10:41[ERROR]failed to get host by name [88864288.vicp.net] ...

00:11:12[ERROR]failed to get host by name [88864288.vicp.net] ... ;

Failure cause

Log shows the domain name parsing fails, indicating that the operator can not resolve the

DSC domain name DNS address IP.

Page 87: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 3

H7000 Series DTU User Manual

Solution

Define the "IP address" in the "run parameters" parameter "DNS" for "8.8.8.8"".

The DNS address 8.8.8.8 can be used in any public network environment, parsing fast, and relatively s table.

4.5 Local software upgrade

4.5.1 H7000 upgrade tools upgrading

Step 1 Double click to run the upgrade tool (H7000 series upgrade tool 20150106), open the upgrade tool main interface.

Step 2 Select "baud rate" to keep the default value "115200", click "select" to open the select upgrade file window.

Currently, the DTU upgrade tool supports automatic matching upgrade file types , without having to

choose here.

Step 3 Select the upgrade serial port "COM1" you want to use, and then click “Start” upgrade

Click Start upgrade, and then restart the device, otherwise the upgrade can not connect

the device.

The official upgrade process, the upgrade interface prompts similar to start to upgrade,

and the "state" and "progress" has the corresponding display information.

The upgrade process is likely to last for 1 to 3 minutes. Please be patient (depending on the type of upgrade file, depending on the actual upgrade time). After the upgrade is successful, the interface prompts to upgrade the success of the information, as shown in Figure 4-5.

4.5.2 Integrated tool box upgrading

Step 1 Run the DTU Integration Kit, select the smart upgrade, select the upgrade file (bin file),

and then click "start", as shown below.

At present, the DTU integrated tool box supports automatic matching upgrade file type, without having

to choose. Dual serial version of the debugger through the mouth to upgrade, upgrade the default baud rate of 115200.

Page 88: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 4

H7000 Series DTU User Manual

Figure 4-1 Upgrade via DTU tool

When you click start, restart your device, or you cannot connect to the device while

upgrading.

Step 2 After waiting to upgrade the page, enter the upgrade countdown, countdown time is 30s, this time to the device to re power, upgrade began.

Page 89: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 1

H7000 Series DTU User Manual

Terms

K

Extended AT

instruction Our company follows the standard AT command format to configure and manage a set of commands for DTU devices. It can realize the configuration of equipment parameters, query parameters, equipment restart and so on.

T

Transparent

data

In the network packet, there is no additional protocol in the TCP/IP protocol.

Communication

mode Data transmission mode of DTU on network. Can use TCP protocol, UDP protocol, but also can transfer data.

Channel mode DTU work mode. For example, when communicating with a DSC, it is said to be a

single channel and multiple channels when communicating with multiple DSC.

U

UART Universal Asynchronous Receiver/Transmitter. UART is a parallel input into a serial output of the chip, usually integrated on the motherboard, most of the 16550AFN chip.

X

Virtual data private network

Techniques for establishing a private network on a public network. It is called the virtual network, mainly because the physical connection between any two nodes of the VPN network and the traditional private network required end-to-end architecture, but provided in the public network service provider network platform, such as Internet, ATM (asynchronous transfer mode), Frame Relay (frame relay) the logical network on the user

data in the logical link. It covers the extension of a private network for encapsulation, encryption, and authentication links across shared networks or public networks.

Page 90: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

Hongdian Corporation 2

H7000 Series DTU User Manual

Abbreviation

ATM Asynchronous Transfer Mode

DCE Data Circuit Terminal Equipment

DSC Data Service Center

DTE Data Terminal Equipment

DTU Data Terminal Unit

GPRS General Packet Radio Service

GSM Global System for Mobile

I

IP Internet Protocol

R

RTU Remote Terminal Unit

S

SIM Subscriber Identify Module

SMS Short Message Service

T

TA Terminal Adapter

TE Terminal Equipment

TCP Transmission Control Protocol

UDP User Datagram Protocol

Page 91: H7960 3G 4G Router User Manual - img.hongdian.comimg.hongdian.com/UploadFiles/Files/Product_Manual... · DTU two development of the data collection on front nozzle, by PLC (Programmable

F14 - F16, Tower A, Building 14, No.12, Ganli 6th Road, Longgang District, Shenzhen 518112, China.

+86-755-88864288-5 +86-755-83404677 hongdianchina

www.hongdian.com [email protected] Hongdian_China

Create smart things