haemodynamics during vaginal and caesarean delivery in

74
Haemodynamics during Vaginal and Caesarean Delivery in Healthy Parturients PhD Thesis Jana Christine Kuhn Department of Anaesthesia, Critical Care and Emergencies Bærum Hospital, Vestre Viken Health Trust Faculty of Medicine University of Oslo 2017

Upload: others

Post on 23-Jan-2022

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Haemodynamics during Vaginal and Caesarean Delivery in

Haemodynamics during Vaginal and Caesarean Delivery

in Healthy Parturients

PhD Thesis

Jana Christine Kuhn

Department of Anaesthesia, Critical Care and Emergencies

Bærum Hospital, Vestre Viken Health Trust

Faculty of Medicine

University of Oslo

2017

Page 2: Haemodynamics during Vaginal and Caesarean Delivery in

© Jana Christine Kuhn, 2017 Series of dissertations submitted to the Faculty of Medicine, University of Oslo ISBN 978-82-8377-147-3 All rights reserved. No part of this publication may be reproduced or transmitted, in any form or by any means, without permission. Cover: Hanne Baadsgaard Utigard. Print production: Reprosentralen, University of Oslo.

Page 3: Haemodynamics during Vaginal and Caesarean Delivery in

What lies behind us and what lies ahead of us are tiny matters compared to what lies within us.

Ralph Waldo Emerson To My parents. Your unwavering support, wise counsel, and help to place things in the right order of importance have grounded and sustained me in all of my endeavours. My late brother Jörg. The memory of your spirit, your sense of humour, and your matchless laughter continue to brighten my mind. I will carry you with me wherever I go. My family and friends. You all are a part of who I am, and I treasure what you have given me on my way. Nicole, Bertrand, Ida, Anna, and Matthias. Your care and support are invaluable to me. Fred. You have stood by my side, lifted my spirits, and had trust in me even in times when I myself had none. Thank you, simply, for everything.

Page 4: Haemodynamics during Vaginal and Caesarean Delivery in
Page 5: Haemodynamics during Vaginal and Caesarean Delivery in

1

Acknowledgements 2 Papers Included in this Thesis 5 Abbreviations 6

1. Background 7 1.1. The Research Field of this Thesis ………………………………………………………………… 7

1.2. Spinal Hypotension during Caesarean Delivery …………………………………………………. 8

1.3. Haemodynamic Impact of Labour and Vaginal Delivery ……………………………………...... 10

1.4. Haemodynamic Monitoring in the Obstetric Context …………………………………………..... 11

2. Review of the Literature 12 2.1. Prophylactic Methods against Spinal Hypotension during Caesarean Delivery ……………... 12

2.2. Research on Haemodynamics during Labour and Vaginal Delivery ………………………….. 16

3. Aims of this Thesis 21

4. Methods 22 4.1. Basic Methodological Characteristics ……………………………………………………………. 22

4.2. Study Population ……………………………………………………………………..…………….. 23

4.3. Ethical Approval …………………………………………………………………..………………… 23

4.4. Main Haemodynamic Monitoring Method ………………………………………………………… 24

4.5. Data Material ……………………………………………………………………..…………………. 24

4.6. Statistical Models …………………………………………………………………………………… 26

5. Synopsis of Results 27 5.1. Results of Study I ……………………………………………………………………..……………. 28

5.2. Results of Study II ……………………………………………………………………..…………… 30

6. Methodological Considerations 32 6.1. Basic Methodological Characteristics ……………………………………………………………. 32

6.2. Study Population ……………………………………………………………………..…………….. 32

6.3. Ethical Aspects ……………………………………………………………………..………………. 33

6.4. Main Haemodynamic Monitoring Method ………………………………………………………... 33

6.5. Analysis and Presentation of Data ………………………………………………………………... 35

6.6. Validity ……………………………………………………………………..………………………… 37

7. Discussion of Results 42 7.1. Discussion of Study I ……………………………………………………………………..………… 42

7.2. Discussion of Study II ……………………………………………………………………..………... 48

7.3. Comment across Study I and II…………………………………………………………………….. 53

8. Conclusions 54

9. Clinical Implications 55

10. Future Research 56

11. References 58

Papers I and II 67 Appendix

Page 6: Haemodynamics during Vaginal and Caesarean Delivery in

2

ACKNOWLEDGEMENTS

Writing this note of thanks closes a circle whose end often seemed out of sight during the rather intense past eight years, and has me look back to its beginning, before I embark on a fresh section of life. This thesis was primarily motivated by clinical interest and by my wish to contribute to the continuing process of improving the clinical management of parturients. If it had not been for that, I would most likely have never completed the PhD programme, which I signed up for after commencing the research itself, and which has demanded important personal and professional sacrifices on the way. I am pleased that this project has brought forth some interesting and useful findings, yet these are very tiny pieces in the large mosaic of past, current, and future obstetric anaesthesiological research. Studying this field has filled me with interest, inspiration, and deep respect towards the gifted clinicians and researchers out there, but it has also filled me with a great deal of self-consciousness concerning the limits of my own knowledge, reason, and skills. Arriving at the end of this project, I feel immense gratitude for every form of support that I have received along the way. First, I would like to thank the University of Oslo for the opportunity to take part in their PhD programme. The studies in this project were conducted at Bærum Hospital, Vestre Viken Health Trust; and at Ullevål, Oslo University Hospital. I warmly thank the South-Eastern Norway Regional Health Authority for contributing towards my scientific work through a governmental research grant. I would also like to thank the following institutions for their provision of facilities, equipment, assistant medical staff, financial resources, and general support:

• The Department of Anaesthesia, Critical Care and Emergencies at Bærum Hospital; the Research Department at Bærum Hospital; the hospital management of Bærum Hospital; and the Unit for Research and Innovation, all of which are part of Vestre Viken Health Trust.

• The Department of Anaesthesia and the Department of Research and Development; both of which are part of the Division of Emergencies and Critical Care at Oslo University Hospital.

I feel honoured that Paper I was distinguished with the 2017 Vestre Viken Research Award. I warmly thank the jury and the Health Trust for the commendation and support of this work. Deep gratitude goes to my principal supervisor Eldrid Langesæter for taking on the mentor assignment for my PhD despite her high workload with other clinical and scientific obligations. With her professional expertise, rational attitude, and high moral integrity, she has been a solid rock in the surf throughout this project. I also appreciate that she always conveyed confidence in my commitment and capabilities. I am very grateful for the friendly guidance during drafting, planning, and beginning these studies, and for the many pieces of valuable strategical and scientific advice that I have received from my co-supervisor Leiv Arne Rosseland. His profound research experience and his co-authorship have been of great benefit for this project. Vegard Dahl deserves credit for his valuable support in the drafting, planning, funding, and launching of this project, for his general backing and logistic assistance during patient inclusion in Study I, and for his contributions as co-author. I count myself fortunate to have received assistance from our precious research nurse Elisabet Andersson. Her clinical skills, outstanding dedication, and excellent sense of organisation deserve sincere recognition for allowing patient inclusion in Study I to run smoothly and within a time frame of three years. I greatly appreciate her lovely personality and her sense of humour, which have made the collaboration even more enjoyable. Special thanks also go to Tor Hugo Hauge, who, sacrificing a great deal of his leisure time, provided irreplaceable support with the handling of our vast haemodynamic dataset, with the creation of illustrations, and with the revision of Paper I.

Page 7: Haemodynamics during Vaginal and Caesarean Delivery in

3

I further thank Magne Thoresen and Ragnhild Sørum Falk for their precious support with the statistical analysis of the complex longitudinal data and for their helpful contributions during the publication process of Paper I and II, respectively. I consider it a stroke of luck that I, during the phase of data analysis, was assigned an office desk at the outstandingly harmonious and inspiring work environment of the Bærum Research Department. Although I was not affiliated administratively, I felt welcome from the very first moment. I am deeply grateful to Arnljot Tveit, Mona Olufsen, and the entire group for their candid friendliness, encouragement, and great amount of helpful general advice. My warmest appreciation also goes to the following:

• The participants in both studies for taking part in the project and for their positive attitude towards clinical research.

• The anaesthetist nurses and doctors at Bærum for being such a nice, dynamic, and positive crew and for their support in patient recruitment and the conducting of Study I even when this resulted in supplemental work; extra thanks to those of you who have been particularly supportive either with practical tasks, general backing, or precious feedback and advice.

• Pharmacists Torill and Jarle for randomisation and preparation of study medicine in Study I, as well as for their general flexibility and positivity.

• Kari and Stein for leg wrapping in all parturients in Study I, as well as for their reliable and good-humoured working attitude.

• The postoperative nurses for reliable and motivated follow-up of the patients.

• The secretaries Cathrine and Nina for their friendly and reliable help with miscellaneous formalities.

• The midwives, obstetricians, and directors of the obstetric wards at Bærum Hospital and Ullevål Hospital for their friendly and good cooperation.

• The Regional Ethics Committee, the Data Inspectorate at Oslo University Hospital, and the Norwegian Medicines Agency for their sensible contributions to our study protocols.

• The editors and anonymous referees during the peer review of our papers for their constructive critiques and useful suggestions that improved our manuscripts.

• The outpatient surgical clinics for sport injuries for the freelance position that enabled part-time clinical work during the years of unpaid research.

• The directors of the Department of Anaesthesia and the Surgical Division at Lovisenberg Hospital for their general supportiveness and for the opportunity to work in a clinical part-time position while I was writing my dissertation.

• The entire office staff at the Faculty of Medicine, and Kari-Anne Bjørnerud in particular, for their helpful and kind support with miscellaneous questions and formal tasks concerning the PhD programme.

Thank you, all those who have lent a helping hand here and there, encouraged me, or made things easier simply by showing goodwill and spreading positive energy. Your supportiveness was noticed and greatly appreciated. Oslo, November 2017

Jana C. Kuhn

Page 8: Haemodynamics during Vaginal and Caesarean Delivery in

4

Page 9: Haemodynamics during Vaginal and Caesarean Delivery in

5

PAPERS INCLUDED IN THIS THESIS Paper I

Kuhn JC, Hauge TH, Rosseland LA, Dahl V, Langesæter E.

Hemodynamics of Phenylephrine Infusion versus Lower Extremity Compression during Spinal

Anesthesia for Caesarean Delivery: A Randomized, Double-Blind, Placebo-Controlled Study.

Anesth Analg 2016;122(4):1120-9.

Paper II

Kuhn JC, Falk RS, Langesæter E.

Haemodynamic changes during labour: continuous minimally invasive monitoring in 20

healthy parturients.

Int J Obstet Anaesth 2017;31:74-83.

Page 10: Haemodynamics during Vaginal and Caesarean Delivery in

6

ABBREVIATIONS

General abbreviations CD Caesarean delivery

CO Cardiac output

CVP Central venous pressure

HR Heart rate

SAP Systolic arterial pressure

SHT Spinal hypotension

SV Stroke volume

SVR Systemic vascular resistance

VD Vaginal delivery

Treatment group abbreviations Phe Phenylephrine group in Study I

Leg Leg wrapping group in Study I

Control Sham treatment group in Study I

Page 11: Haemodynamics during Vaginal and Caesarean Delivery in

7

1 BACKGROUND

1.1 The Research Field of this Thesis Childbirth is ‘one of life’s biggest cardiovascular challenges’.1 Pregnant women, during

vaginal and surgical delivery, constitute a large and vulnerable group of patients with a need

for optimal treatment, both under normal and complicated conditions.2-4 Understanding and

optimisation of maternal haemodynamics is a prerequisite for maximal safety and wellness of

the mother and the newborn.2-4 Both maternal and neonatal safety have been improved

considerably during the past decades.5,6 Lately, however, the prevalence of risk factors such

as obesity and cardiac disease among parturients has increased. So has maternal mortality

from indirect death, i.e. from ‘diagnosed or undiagnosed disease which is aggravated by the

physiological effects of pregnancy or childbirth’.5,6 ‘Substandard care’, in part due to failed

recognition or inappropriate management of (sub-) acute cardiac pathology, was identified in

half of indirect maternal deaths in the UK between 2006 and 2008.5 Ameliorating an in-depth

understanding of maternal circulation, and optimising cardiovascular management in the

obstetric context, still constitute an important research focus in order to further improve

maternal and neonatal safety under physiological and pathological conditions.4,6 This Ph.D.

project aimed to contribute to this continual process with two studies on haemodynamics in

healthy parturients.

Parturients may give birth either by vaginal delivery (VD), or by caesarean delivery (CD).

Caesarean delivery may be performed in (semi-) acute settings, such as delayed labour

progress, compromised maternal condition, or because the foetus becomes critically stressed

during ongoing labour. By contrast, elective CD is scheduled a few days or weeks in advance,

because of maternal request, breech position of the foetus, or complications anticipated with

VD. Caesarean delivery can be performed either under general anaesthesia or with the help

of regional techniques, i.e. spinal or epidural anaesthesia. Regional anaesthesia is a

generally safe and convenient technique in which a local anaesthetic is used to anaesthetise

only the lower part of the body, thus avoiding the disadvantages of general anaesthesia.7

Spinal anaesthesia is used most frequently, because of its simplicity, rapid onset, low drug

dose, and good muscle relaxation during surgery.2,8

Both VD and anaesthesia for CD can have a profound impact on maternal circulation. During

labour contractions, pain and physical strain expose the mother to haemodynamic stress, but

the evidence base is limited since only a few studies have investigated the haemodynamic

effects of labour.9-18 Women delivering by elective CD escape contractions, but may suffer

from spinal hypotension, i.e. a decrease in blood pressure which is a frequent side effect of

spinal anaesthesia. In spite of numerous studies over the past decades, no final consensus

on optimal prophylaxis against spinal hypotension during CD had been established by the

time we started our research project.2,19-21

Page 12: Haemodynamics during Vaginal and Caesarean Delivery in

8

Both of our studies examined the haemodynamic condition of healthy parturients in an

obstetric-anaesthesiological context. Study I compared two different methods for stabilising

maternal haemodynamics during spinal anaesthesia for CD. Study II investigated the impact

of labour and VD on maternal haemodynamics.

The following chapters will sum up previous research on haemodynamics during caesarean

and vaginal delivery, address the methodological aspects of this Ph.D. project, present the

results of both studies, and discuss our findings in the context of current evidence.

1.2 Spinal Hypotension during Caesarean Delivery Most caesarean deliveries are performed under spinal anaesthesia. Injection of a local

anaesthetic into the spinal fluid leads to the blocking of both sensory and motoric, but also

autonomic nerve fibres.22

Inhibition of thoracolumbal sympathetic nerve impulses happens rapidly after injection, and

results in the vasodilation of peripheral blood vessels, which in turn leads to a reduction of

systemic vascular resistance (SVR) and a subsequent decrease in arterial blood pressure.

This so-called spinal hypotension (SHT) can have negative consequences for mother and

foetus. Maternal tachycardia or bradycardia, nausea and vomiting are frequent, and, in worst

cases, cardiovascular collapse may occur.22 Furthermore, placental blood supply may be

reduced, which can give rise to acidosis and reduced vitality in the newborn. A drop in arterial

blood pressure can generally be treated quite rapidly by a choice of medicaments and fluids.

However, a period of several minutes may pass from the event to the revealing

measurement, and to the effect of the then given treatment. In some parturients, persistent

refractory hypotension may lead to prolonged and severe symptoms despite aggressive

therapeutic intervention.22

Prevention of SHT has been called ‘the Holy Grail’ within obstetric anaesthesia,21,23 and a

range of methods – such as prophylactic medications, intravenous fluid regimens, positioning

techniques during spinal anaesthesia and CD, and other mechanical manoeuvres – have

been studied and discussed internationally for many years. None of the methods had optimal

effect, and international guidelines for prophylaxis against haemodynamic instability during

CD did not exist when we started Study I.2 Prophylactic routines differed significantly

between, and even within, hospitals and countries, and in many places no specific

prophylaxis was used at all.21,24-26

One prophylactic strategy is the use of vasoactive medicaments, and various types and

regimens have been studied.20,23 Administration of one of these vasopressors, phenylephrine,

in combination with crystalloid cohydration, has been established as the ‘gold standard’

prevention technique during the past decade.27 Phenylephrine is a pure α1-adrenergic agonist

that causes vasoconstriction via stimulation of post synaptic α1-fibres, and thereby increases

SVR and arterial blood pressure.28,29 Different dosage regimens have been investigated, but

Page 13: Haemodynamics during Vaginal and Caesarean Delivery in

9

not led to a definite consensus yet.27,30 Prophylactic high-dose phenylephrine infusion may

entirely prevent SHT, but on the other hand may cause reactive hypertension, and reduce

maternal heart rate (HR) and cardiac output (CO), which, if profound, may reduce placental

blood supply.19,31-34 Continuous low-dose phenylephrine infusion has been shown to stabilise

systolic arterial blood pressure (SAP) without reactive hypertension or a significant reduction

in CO, but an initial drop in SAP has not been prevented.19 Finding the optimal pattern for

prophylactic administration of phenylephrine has been considered to be of high clinical

interest.24,35,36

Several mechanical prophylactic strategies have also been examined. One of the more

frequently studied alternatives among them is lower limb compression, which may for

example be effectuated by wrapping the legs with tight bandages. This is meant to prevent

hypotension by mechanically counteracting venous blood pooling and loss of fluid into

connective tissue of the lower extremities, thus increasing venous return. Only a few studies

have been conducted,2,37-40 showing a moderate stabilising effect on SAP. Small sample

sizes and methodological weaknesses have contributed to the absence of definitive

recommendations for clinical practice, and no data on international commonness of use have

been published. However, a number of institutions in different countries have based their

prophylaxis protocols on leg wrapping.41-44 Since the method has been applied in clinical

practice despite the lack of high-quality scientific evidence, we considered detailed

examination of the effect of leg wrapping in a larger, well-designed study to be of interest.

Phenylephrine and leg wrapping have never been compared in the setting of spinal

anaesthesia for CD. As recent evidence shows, a sudden and marked arterial vasodilation is

the main haemodynamic effect of spinal anaesthesia.19,32 The arteriolar vasoconstrictor

phenylephrine directly counteracts this side effect.35 By contrast, the leg wrapping approach is

based on the historic, but lately disestablished, concept of impaired venous return being the

most relevant factor in spinal hypotension.35,41,45 The fundamental change in

pathophysiological understanding of spinal hypotension, moving the focus from venous to

arterial circulation, had just emerged in the year preceding Study I.19 Comparison of the

detailed haemodynamic effects of the two physiologically different prophylactic approaches

seemed particularly interesting in light of this recent paradigm shift.

In summary, SHT during CD was considered a central and incompletely solved problem

within obstetric anaesthesia.24,35,36 Since a previously studied continuous low-dose

phenylephrine infusion stabilised SAP well, but did not prevent an initial drop in SAP,19 we

thought to investigate whether adding an initial bolus to this regimen would improve its effect.

Further, we thought that comparison of this regimen with leg wrapping, using advanced

haemodynamic monitoring, might be an interesting contribution to the evidence base on the

pathophysiology and the prevention of SHT.

Page 14: Haemodynamics during Vaginal and Caesarean Delivery in

10

1.3 Haemodynamic Impact of Labour and Vaginal Delivery During pregnancy, women undergo significant changes with regards to their haemodynamic

condition. In pregnant women at term, SVR is reduced, and blood volume and CO are

increased by 30% to 50%. Healthy pregnant women generally tolerate these changes

well.46,47

The process of birth through the natural birth canal is divided into labour stage 1, with

contractions that lead to the gradual opening of the uterine cervix, and labour stage 2, with

active pressing during contractions in order to move the foetus downward, including vaginal

delivery, the last few contractions leading to parturition. Delivery of the foetus and, usually a

few minutes later, of the placenta are followed by the postpartum period.48 Haemodynamic

changes during this process may be profound, but have only been investigated very little so

far. Hence, the literature is sparse and inconsistent.18,49 Most studies date back to the period

between the 1950s and the 1970s, and some are based on very low patient numbers.9-16 To

our knowledge, none of the previous studies provided continuous CO monitoring during all

labour stages.

A case report based on continuous minimally invasive monitoring described profound

decreases in CO and stroke volume (SV), and marked increases in SVR, SAP and HR during

the second stage of labour in a pre-eclamptic parturient.49 The same monitoring method

revealed similar, major haemodynamic changes in three healthy parturients with effective

epidural analgesia during contractions in both labour stages (unpublished data from Oslo

University Hospital, Rikshospitalet).

Healthy women usually tolerate labour well, but detailed knowledge about the haemodynamic

changes during labour and VD is important for optimal management both of healthy

parturients and of parturients with reduced cardiac reserve. Severe cardiac compromise is

acknowledged as a maternal indication for CD, but for the majority of parturients with cardiac

compromise, current guidelines recommend VD.1,50-52 While the guidelines emphasise the risk

of haemorrhage, infection, thrombosis, and anaesthesiologic complications in case of CD,

some authors are concerned that the impact of labour on maternal circulation might be under-

recognised.17,49

The idea behind Study II was to examine the challenge that labour poses to maternal

circulation. We thought that continuous invasive monitoring in a group of healthy parturients

might improve insight into haemodynamic changes during both labour stages and VD.

Thorough appraisal of haemodynamics in healthy parturients might be a valuable foundation

for clinical judgement regarding, and future research into, physiological and pathological

conditions.

Page 15: Haemodynamics during Vaginal and Caesarean Delivery in

11

1.4 Haemodynamic Monitoring in the Obstetric Context The most frequently used form of haemodynamic monitoring in parturients is intermittent non-

invasive blood pressure measurement. The technique is simple to perform but does not

provide data on any other haemodynamic variables, and intervals between measurements

are usually one or several minutes.27,53 Most studies on the prevention of spinal hypotension

during CD are based on intermittent noninvasive blood pressure measurement, which is why

they provide limited information on the haemodynamic changes caused by spinal

anaesthesia.54

Advanced haemodynamic monitoring measures a wider range of variables, such as CO, SV,

and SVR. Techniques of the past involved central venous and arterial catheterisation, and

allowed serial single CO measurements using various types of dye dilution. Suffering from

disadvantages such as a high degree of invasiveness, a low number of measurements per

time, limited reliability for the detection of rapid changes, and high sensitivity to noise,18 they

have been employed in only a few studies in the obstetric context.9-16,55 Hence,

haemodynamic pathophysiology during labour, and during vaginal and caesarean delivery,

has been sparsely elucidated for a long time.18,27,49

Thanks to the recent development of modern noninvasive and minimally invasive devices,

haemodynamic monitoring in parturients has evolved over the past decade.53 Modern CO

monitors are based on transthoracic or whole-body electrical impedance, finger-cuff

plethysmography, ultrasound, or peripheral arterial catheterisation and arterial wave form

analysis, facilitating advanced pathophysiological insight while avoiding the risks of historic

invasive techniques. Their use in recent studies has improved the evidence base for

haemodynamics during CD,53,56 but only few single cases have been examined with modern

technology during labour.53 The minimally invasive device LiDCOplus provides calibrated

beat-by-beat data on blood pressure, HR, SV, CO, and SVR, and is valid in detecting rapid

changes in haemodynamic trends.53,57

Prior to Study I, only two studies on the prevention of spinal hypotension in healthy pregnant

women during CD used continuous minimally invasive haemodynamic monitoring.19,32 None

of the previous studies on lower limb compression has, to our knowledge, measured blood

pressure continuously or examined haemodynamic variables other than blood pressure.2,37-41

We are not aware of any previous study that has achieved performing continuous CO

measurements during all stages of labour.

Page 16: Haemodynamics during Vaginal and Caesarean Delivery in

12

2 REVIEW OF THE LITERATURE

2.1 Prophylactic Methods against Spinal Hypotension during Caesarean Delivery The importance of the prevention of spinal hypotension during CD was emphasised by the

Cochrane Collaboration in 2006. They concluded that maternal hypotension has an incidence

approaching 100%, and may not only lead to nausea and vomiting, but also to more serious

complications, such as impaired consciousness and pulmonary aspiration for the mother, and

hypoxia, acidosis, and neurological injury for the baby. Despite intense research over the past

decades, however, no ideal preventive technique had been established yet, and spinal

hypotension remained a common clinical problem.2

At that time, profound venodilation, with a following reduction of venous return and CO, was

considered the primary cause of spinal hypotension, aggravated to some degree by

aortocaval compression from the uterus.2 Current prophylactic strategies therefore mainly

focused on improving venous return to the heart. The spectrum of studied interventions

included several variants of maternal positioning to influence distribution of anaesthesia and

of circulating blood, various intravenous fluid regimens to enlarge effective blood volume, and

different techniques of lower limb compression to minimise peripheral venous pooling. Other

studies, by contrast, explored vasoactive drugs. Most of these trials examined ephedrine, and

a few trials examined phenylephrine, metaraminol, angiotensin, or dopamine.2

The Cochrane Collaboration assessed 75 randomised controlled trials comparing prophylactic

interventions. Whereas most methods had some preventive effect, no single intervention

eliminated the need for additional treatment of spinal hypotension.2

Phenylephrine

This pure α1-adrenergic agonist causes vasoconstriction via stimulation of post-synaptic α1-

fibres, and thereby increases SVR. Its use had already been reported in the 1970s,58,59 but

then generally been avoided for several decades, because of concerns about its potential

adverse effects on uterine blood flow.60 However, a favourable effect of α1-adrenergic

agonists on maternal blood pressure in a few studies61-64 inspired Ngan Kee et al. to conduct

research into α1-adrenergic agonists. They first examined metaraminol65 and then

phenylephrine,66 showing that it was efficient in preventing spinal hypotension without leading

to neonatal acidosis. After a previous Cochrane review had suggested directing future

research to a combination of interventions,67 Ngan Kee et al. completely averted a decrease

in blood pressure by combining a prophylactic high-dose phenylephrine infusion with rapid

crystalloid cohydration in 2005.68 This study marked a turning point in the prevention of spinal

hypotension. Ngan Kee et al. followed up by showing that preventive phenylephrine caused

less neonatal acidosis than ephedrine when each of the drugs was used in high doses,69,70

and by focusing on the dosage regimen of phenylephrine.66,68,71-74

Page 17: Haemodynamics during Vaginal and Caesarean Delivery in

13

Most Ngan Kee’s work aimed at keeping the blood pressure close to baseline, by fine-tuning

continuous high-dose infusions started at rates around 100 µg/min, lately even by the

sophisticated method of closed-loop feedback computer control.73-75 However, the price for

incidences of hypotension down to 1,9%,68 were concomitantly high incidences of reactive

hypertension (up to 47%) and of bradycardia (up to 32%).66,71 Ngan Kee accepted these with

the argument of unabated maternal wellbeing and excellent neonatal outcomes.30,76

The high-dose approach was questioned in 2008 by Langesæter et al., who introduced a

model of weight-based low-dose phenylephrine infusion.19 A continuous rate of 0.25

µg/kg/min (resulting in doses between 15 µg/min and 25 µg/min), together with moderate

crystalloid coload (750 ml NaCl), reduced the incidence of rescuepressor-requiring SHT to

40%, and to 25% when combined with low-dose spinal anaesthesia. While an initial drop in

blood pressure was not prevented by either of the regimens, the severity of hypotension was

significantly reduced and no reactive hypertension occurred.

More importantly, using continuous minimally invasive monitoring, Langesæter et al.

demonstrated that spinal anaesthesia leads to an immediate and profound reduction in SVR,

and a compensatory increase in CO.19 In 2009, Dyer et al. confirmed these findings, also with

the use of beat-by-beat monitoring.32 These two studies contradicted the historic concept,

which had postulated that impairment of venous return and, consequently, of CO, were the

primary cause of spinal hypotension. The observation that arterial instead of major venous

dilation is the main haemodynamic effect of spinal anaesthesia explains the superiority of α1-

adrenergic agonists over methods increasing venous return.27 This shift in pathophysiological

understanding of spinal hypotension was supported by an editorial by Sharwood-Smith and

Drummond.45

Dyer et al. also demonstrated the haemodynamic effects of therapeutic boluses of 80 µg

phenylephrine, which were an increase in SVR of approximately 75%, and a decrease in CO

of about 25%, and suggested that phenylephrine boluses should be lower than 80 µg.32 The

authors recommend the use of low-dose phenylephrine, emphasising the adverse impact that

reactive hypertension with subsequent bradycardia and reduced CO may have on pregnant

women with cardiac risk factors, and, via reduction of uteroplacental bloodflow, on

precedently compromised foetuses.32 Based on the observation of a strong correlation

between CO and HR, HR might serve as a clinical surrogate marker for CO in parturients

without advanced haemodynamic monitoring, and should be kept close to baseline during

spinal anaesthesia for CD.27,32,35

In terms of neonatal outcome, Dyer et al. confirmed that ephedrine causes more acidosis

than phenylephrine, but reasoned that the extent of this acidosis is probably without clinical

significance in healthy neonates.32 Clinical neonatal outcomes were excellent in spite of

umbilical cord acidosis after high doses of ephedrine, and more placental drug transfer of

ephedrine than of phenylephrine in previous studies,69,70 and both phenylephrine and

Page 18: Haemodynamics during Vaginal and Caesarean Delivery in

14

ephedrine are considered safe for the foetus when used in normal clinical doses in healthy

parturients.27,60 The most relevant clinical advantages of phenylephrine over ephedrine are

thus quicker onset of action, and better restoration of maternal haemodynamics.32,77

Vasopressor choice should therefore be guided by maternal circulation. That means using

phenylephrine as first-line agent against the typical response to spinal anaesthesia, which is

hypotension accompanied by tachycardia, and using ephedrine and an anticholinergic in the

rarer case of hypotension and immediate bradycardia.27,35

After Study I had been started in 2009, several trials on different phenylephrine regimens

reinforced the evidence in favour of low continuous rates. Using a suprasternal Doppler

technique, Stewart et al. demonstrated clinically insignificant improvement of blood pressure

stability at the expense of significantly more pronounced reduction in HR and CO (by 20%),

when comparing high with moderate and low infusion rates (100 µg/min versus 50 µg/min and

25 µg/min).33 Their observations were supported by Allen et al., who reported dose-

dependent decreases in incidence and severity of hypotension, but corresponding increases

in incidence of hypertension (up to 82%) and bradycardia (up to 32%);78 in conjunction with

crystalloid coload, rates of 25 µg/min and 50 µg/min obtained the best overall haemodynamic

stability when compared to rates of 75 µg/min and 100 µg/min. A clinically titrated moderate

dose regimen (starting at 67 µg/min after moderate crystalloid prehydration) by Cooper et al.

generated similar incidences of hypotension and hypertension as the above-mentioned

moderate infusion rates.79

In 2012, Doherty reported that high-dose phenylephrine infusion (120 µg/min), compared with

boluses (120 µg) given in response to blood pressure at or below baseline, resulted in a

higher total phenylephrine dose, but in a similar decrease in blood pressure and cardiac

output, and in similar incidences of hypotension, hypertension, bradycardia, and nausea.34

Slightly better attenuation of the initial decrease in blood pressure was achieved by

intermittent boluses (5% versus 10% decrease from baseline),34 the size of which was based

on calculations on ED95 from a previous study.80 Against the background of the

haemodynamic changes observed by non-invasive CO monitoring, Doherty contemplated the

benefit of an initial bolus dose, but joined authors arguing for low-dose infusion rates.34

In 2013, Ngan Kee et al. administered phenylephrine at a moderate start rate (50 µg/min) by

a closed-loop titration system, and used suprasternal Doppler ultrasound to assess the

prophylactic effect of glycopyrrolate on cardiac output.75 An increase in HR and CO, but also

in incidence of hypertension (44% versus 17%), as well as a decrease in accuracy of blood

pressure control, and similarly low incidences of bradycardia, hypotension, and nausea in the

glycopyrrolate versus the control group, led to the conclusion that maintaining CO by careful

vasopressor titration might be a more advantageous strategy than routine use of

anticholinergic drugs for the prevention of bradycardia. Of note, the median phenylephrine

rates administered by the computer-controlled system were 31 µg/min and 34 µg/min,

Page 19: Haemodynamics during Vaginal and Caesarean Delivery in

15

respectively,75 and 40 µg/min in a study comparing computer-controlled with manually

controlled phenylephrine infusion,74 i.e. rather low continuous doses. Closed-loop systems as

investigated by Ngan Kee73-75 adjust vasopressor doses based on blood pressure only, and

should probably be improved by some algorithmic adjustments such as integration of HR, in

regard to overall haemodynamic condition.77 Because this league of technical sophistication

is in any case unlikely to reach widespread clinical availability in the near future,75 variable-

rate infusions based on a clinically guided titration protocol have been recommended as a

more realistic clinical approach on a global basis.27,30

As several recent reviews sum up, studies during the past decade have improved the

understanding and management of spinal hypotension considerably.3,27,30,35,36,81-83 Continuous

invasive monitoring has led to the paradigm shift that spinal hypotension is primarily caused

by a reduction in afterload due to arterial vasodilation, and not by a reduction in preload and

CO due to increased venous capacitance.19,32 Phenylephrine has been established as the

prophylactic and therapeutic vasopressor of choice, and the evidence base on its use is

growing, but the debate on the optimal dosing regimen in terms of balancing hypotension

against the adverse effects of reactive hypertension, bradycardia and low cardiac output, has

not been concluded.27,30,81 Based on publications before the start of Study I, we reasoned that

the integration of an initial bolus into a low-dose continuous infusion model could prevent the

rapid initial decrease in blood pressure, while avoiding the side effects from higher

phenylephrine infusion rates.

Lower limb compression

In the 2006 Cochrane review, pooling of seven methods for lower limb compression showed a

moderate stabilising effect on blood pressure compared to control.2 Already five decades ago,

the idea of impeding blood redistribution to the lower extremities in order to sustain venous

return and thus reduce spinal hypotension, had inspired the investigation of inflatable boots

during CD. In that study, no positive effect on blood pressure was found, but it was noted that

the omission of left uterine displacement may have contributed to the negative findings.84

Fifteen years later, inflatable splints were shown to reduce hypotension from an incidence of

83% to 48%, but the reliability of the method was considered low.85 A sequential compression

device in combination with thromboembolic deterrent stockings merely led to a small and non-

significant reduction in hypotension; however, the study design suffered from serious

methodological weaknesses (lack of blinding, unclear randomisation and allocation

concealment, and protocol violations concerning vasopressor treatment).2,86 Another study

found that the same device reduced the incidence of mean arterial pressure hypotension from

92% to 52%.87

In 1996, compression stockings were shown to reduce nausea and vasopressor use

compared with a control group. The reduction in incidence of hypotension by 29% lacked

statistical significance, which was attributed to low power in connection with the small study

Page 20: Haemodynamics during Vaginal and Caesarean Delivery in

16

size.88 In another trial thromboembolic deterrent stockings were found neither able to prevent

hypotension nor to reduce vasopressor need compared with compression stockings, probably

because of the lower pressure they excerted. 89

The first study using elastic bandages reduced both the incidence (17% vs 83% control) and

the severity of hypotension, measured at one-minute intervals, in 1990, but the sample size

was small.37 The findings were partly confirmed by a larger trial documenting significantly

lower incidence (18%) versus the control (53%).38 According to the authors, the likelihood of

hypotension with leg wrapping was one fifth compared to no intervention, both in their own

study38 and in the precedent one on inflatable splints by Goudie.85 Elastic bandages reduced

the incidence of hypotension compared to the control in another larger study at that time

(15% versus 54%),39 and in a very recent one (40% versus 70%),44 but measurement

intervals in both studies were very wide (five minutes). Also a study testing leg wrapping

against a control under epidural anaesthesia found the incidence of hypotension to be

diminished (23% versus 50%).40

The first trial comparing phenylephrine with leg wrapping was performed by Bjørnestad et al.,

with blood pressure measurements at two-minute intervals, in parturients that were

anaesthetised with epidural anaesthesia for CD.43 Leg wrapping achieved a similar incidence

of hypotension as phenylephrine given in three boluses (50 µg) at five-minute intervals, but,

owing to the lack of a control group, the magnitude of the methods’ prophylactic effect

remains uncertain. Definition of hypotension as a 30% decrease from the baseline

complicates the comparison of incidences with the majority of recent publications, as the

latter generally refer to a 20% threshold.

2.2 Research on Haemodynamics during Labour and Vaginal Delivery Hendricks and Quilligan were among the pioneers of haemodynamic research in labouring

parturients when they used the pulse pressure method to measure CO in 20 healthy

parturients during different labour stages in 1956.9 They found a 30% rise in CO ‘during

effective contractions’, a small drop in CO during ‘bearing down effort without a contraction’,

and a possible increase in CO during ‘bearing down effort with a contraction’. They described

a continuous rise in baseline CO (i.e. CO ‘at rest’ between contractions) during the first labour

stage, a further rise during delivery, and an additional small rise during some minutes

postpartum in some of their patients. The authors acknowledged that heterogeneous timing

and frequency of measurements, as well as limitations of the monitoring method, impaired the

validity of their results. Nonetheless, their study was the first one to examine CO during

labour, and represented an important scientific step at the time.

In 1958, Adams and Alexander followed up by using a blue dye dilution technique to measure

CO during labour stage 1 in 21 healthy parturients.10 During contractions, CO increased in 17

Page 21: Haemodynamics during Vaginal and Caesarean Delivery in

17

of the 21 parturients (by 20%), but in contrast to the study of Hendricks and Quiligan, no

cumulative increase in baseline HR, SV, or CO during labour was found.

In 1966, Winner and Romney used green dye dilution for CO measurements in five healthy

parturients.11 During stage 1 contractions, the authors found increases in SAP and HR, and

either increases (by up to 25%) or decreases (by up to 20%) in CO. Interestingly, the rises in

SAP and HR started prior to palpable contractions. The authors hypothesised that the

increases in SAP were due to increased intrathoracic pressure and to smooth vascular

contraction that occurred simultaneously with myometrial contractions. Cardiac output

measurements during contractions were unreliable because the technique demands steady

CO. Under bearing down effort, SAP and HR increased more than during stage 1, but the

authors did not succeed in detecting CO at all. Based on central venous pressure (CVP) and

right ventricular pressure changes, they postulated that CO diminished during expulsive

effort. They further assumed that SV was slightly diminished during contractions, owing to

decreased filling or increased emptying caused by tachycardia. As in the study of Adams and

Alexander, no cumulative increase was found in the baseline values of any haemodynamic

variables. Postpartum measurements were inconsistent between parturients.

In 1966, Hansen and Ueland observed increases in SAP (by 11%), CO (by 15%), and SV (by

25%), and decreases in HR (by 6%) during contractions in early stage 1 in an unreported

number of healthy parous women. Using green dye dilution, the authors compared the effect

of different analgesic blocks on serial CO measurements. In a subgroup with paracervical and

pudendal block, CO at rest increased progressively during labour (by 40%) and postpartum

(by 60%), due to increases in both HR and SV.12 In parturients with caudal analgesia, there

was no cumulative change in baseline CO during labour, but a postpartum increase in CO (by

60%) and SV (by 80%).

In 1969, Ueland and Hansen again reported a decline in HR (by 15%), and a rise in CO (by

25%) and SV (by 33%), during first-stage contractions, measured with green dye dilution in

23 healthy women in oxytocin-induced labour.13 This time, they examined the haemodynamic

effect of position in nine of the parturients, and found that changes during contractions were

greater in the supine than in the lateral position. Baseline SV and CO, by contrast, were

higher in the lateral position. The authors speculated that scopolamine had been the cause of

tachycardia and decreases in SV during contractions in previous studies.9,10 With 15 single

measurements of CO in each of 23 supine parturients, they found an increase in CO (by 15%

to 20%) during contractions in labour stage 1.14 CO and SV were not measured during stage

2 contractions, but CVP and SAP increased during bearing-down effort. Comparing 10

parturients with local analgesia to 13 parturients with caudal analgesia, progressive rises in

baseline HR, SV, and SAP during labour were found in the former but not in the latter. A

cumulative increase in baseline CO under local analgesia (by 50%) was higher than under

caudal analgesia (by 23%). After delivery, CO increased (by 80% versus 60%) in both

groups. The authors concluded that caudal block limited the cumulative increase in baseline

Page 22: Haemodynamics during Vaginal and Caesarean Delivery in

18

CO, but not the increase in CO during contractions or posture changes. They assumed that

blood redistribution was the common etiologic factor behind CO changes during contractions,

posture changes and postpartum.

In 1970, Lees et al., using green dye dilution in five healthy parturients with epidural

analgesia, found a CO rise (by 20% to 30%), together with increased SV and SAP and

unchanged HR during stage 1 contractions.15 Also this group failed to monitor CO during

stage 2 contractions. The authors found no cumulative increase in CO during labour, but a

postpartum increase in CO (by 40%) due to higher SV. They attributed the rise in CO during

contractions to myometrial autotransfusion, the cumulative increase in CO in some of the

previous studies to pain, and the postpartum rise in CO to caval relief. They hypothesised that

the volume of a possible postpartum autotransfusion is exceeded by the average blood loss

during delivery, and hence does not contribute to increased CO.

In 1970, Niswonger and Langmade compared CO, SVR, HR, and CVP during spinal

analgesia / anaesthesia in 11 vaginal deliveries and nine caesarean deliveries. Using green

dye dilution, they performed five haemodynamic measurements in each parturient; right

before and right after induction of anaesthesia, twice (probably at rest) during the period of

delivery, and postpartum.16 They found a decrease in SVR and an increase in CO (by 20%)

postpartum. Of note, postpartum measurements were taken some unspecified time after

injection of oxytocin. As there were no major differences in haemodynamic values between

the groups, they postulated that CD does not reflect an increased ‘cardiac strain’.

In 1987, Robson et al. performed Doppler and cross-sectional echocardiography at three

points in time during labour stage 1 in 15 healthy women. Increases in SAP, HR, SV, and CO

(by up to 34%) during contractions became greater with the progression of labour. Cumulative

increases in baseline SAP, SV, and CO (by 12%) were also observed.

Ten years later, Filippatos et al. questioned the results of all previous studies, pointing out the

low validity of dye dilution and Doppler measurements in rapidly changing haemodynamic

conditions.18 He himself used bio-impedance in 10 healthy parturients, and found an increase

in CO (by 84%) during stage 1 contractions. This was mainly caused by an increase in SV,

which the author attributed to adrenergic stimulation and blood redistribution from the uterus.

Measurements during stage 2 contractions failed, because of too much noise. Baseline CO

was higher in stage 2 than in stage 1, but did not increase any further after delivery. Filippatos

explained the absence of a postpartum increase in CO as being due to blood loss during

delivery.18

A case report in 2009 described a 50% reduction in CO, a 50% elevation in SVR, a 40%

increase in SAP, and up to a more than 85% increase in HR during stage 2 contractions in an

almost painfree pre-eclamptic parturient with effective epidural analgesia.49 Haemodynamic

variables were monitored with the LiDCOplus device. To our knowledge, this is the first

Page 23: Haemodynamics during Vaginal and Caesarean Delivery in

19

publication based on minimally invasive continuous monitoring, and the first time that CO

measurements were achieved during bearing-down effort.

In 2011, using electrical velocimetry, Archer showed higher baseline CO in left than in right

lateral position, and increases in CO during a few contractions in a pre-eclamptic parturient.90

In summary, there is scarce, conflicting evidence on haemodynamic changes during

labour.18,49 Formerly employed monitoring techniques suffered from disadvantages such as a

high degree of invasiveness, low frequency of measurements, and limited reliability in

unstable haemodynamic conditions.18 These studies represented important scientific progress

at the time, and have created basic knowledge of the haemodynamic impact of labour.

Continuous measurements with modern minimally invasive technology might help to deepen

pathophysiological insight. Successful CO monitoring with LiDCOplus during labour in the

published49 and some unpublished cases at Oslo University Hospital inspired us to study

haemodynamic changes during the entire course of labour in Study II.

Page 24: Haemodynamics during Vaginal and Caesarean Delivery in

20

Table 1. Studies on Haemodynamics during Labour in Healthy Parturients

Monitoring technique

for CO

Parturients analysed

(n)

Baseline

Changes during contractions

During

labour

Post-partum

Labour stage 1

CO

CO

SAP

HR

SV

CO

Hendricks and Quiligan 19569

Pulse Pressure

20 partu-rients with different types of

analgesia

Cumulative increase

Small increase in some partu-rients

n.r.

n.r.

n.r.

+30%

Adams and Alexander 195810

Evans blue dye dilution

21

=

=

+10%

+14%

- 6%

+20%

Winner and Romney 196611

Indo cyanine

green dye dilution

5 partu-rients with inhaled,

local, and intravenousanalgesia

=

Incon-sistent

+25%

+20%

- / +

-20% to +25%

Hansen and Ueland 196612

Indo cyanine

green dye dilution

Unspecified n with pudendal block Unspecified n with caudal block

Cumulative increase up to +40% =

+60% +60%

+11%

-6%

+25%

+15% +15%

Ueland and Hansen 196914

Indo cyanine

green dye dilution

10 partu- rients with local analgesia 13 partu-rients with caudal analgesia

Cumulative increase up to +50% Cumulative increase up to +23%

+80% +60%

+12% +10%

= =

+20% +20%

+20% +20%

Lees et al. 197015

Indo cyanine

green dye dilution

5 partu-rients with epidural

analgesia

=

+40%

up to +15%

=

up to +30%

up to +30%

Niswonger and Langmade 197016

Indo cyanine

green dye dilution

11

n.r.

+20%

n.r.

n.r.

n.r.

n.r.

Robson et al. 198717

Doppler echo-

cardio-graphy

15

Cumulative increase up to +12% in stage 1

n.r.

up to +12%

up to +16%

up to +16%

up to +34%

Filippatos et al. 199718

Bio- Impe-dance

10

Increase up to +23% in stage 2

=

n.r.

+2%

+72%

+84%

Exhaustive presentation of the heterogeneous studies would exceed the capacity of this table, thus only a few

basic characteristics and findings are displayed. n: number of parturients. Postpartum: the immediate postpartum

period. n.r.: not reported. ‘=’: no change. ‘+’: increase. ‘ – ‘: decrease.

Page 25: Haemodynamics during Vaginal and Caesarean Delivery in

21

3 AIMS OF THIS THESIS

The purpose of this thesis is to improve insight into maternal haemodynamics during

caesarean and vaginal delivery.

The aim of Study I was to compare the effect of prophylactic low-dose phenylephrine infusion

to the effect of leg wrapping, and to the effect of sham treatment on maternal haemodynamics

during spinal anaesthesia for CD. Specific objectives were to:

1. compare the effect of the three interventions on SAP;

2. compare the effect of the three interventions on HR, SVR, SV, and CO;

3. examine the haemodynamic effects of a regimen with an initial phenylephrine bolus

before low-dose phenylephrine infusion; and

4. compare the indirect effect of the three interventions on the condition of the newborn,

i.e. on Apgar scores, and on umbilical vessel BE and pH.

The aim of Study II was to examine the effect of labour and VD on maternal haemodynamics.

Specific objectives were to:

5. compare SAP, HR, SVR, SV, and CO during contractions with baseline values in

each labour stage;

6. compare SAP, HR, SVR, SV, and CO during contractions across labour stages;

7. compare SAP, HR, SVR, SV, and CO values at baseline across labour stages; and

8. assess the effect of epidural analgesia on haemodynamics.

Page 26: Haemodynamics during Vaginal and Caesarean Delivery in

22

4 METHODS

Papers I and II contain thorough descriptions of the respective methods. This section

therefore confines itself to a brief summary of the methods, and a few additional details that

are not mentioned in the papers.

4.1 Basic Methodological Characteristics

Table 2. Overview of Study Design

Study I

Study II

Elective caesarean delivery under spinal anaesthesia

Spontaneous labour and vaginal delivery

Population

Healthy parturients at term

Healthy parturients at term

Sample size

120

20

Design

Randomized controlled trial � Double-blinded, parallel group � Three treatment arms:

� Phe: Prophylactic phenylephrine (bolus of 0.25 µg/kg followed by infusion 0.25 µg/kg/min) � Leg: Prophylactic leg wrapping � Control: Sham treatment All groups received cohydration with 1000 ml 0.9% saline infusion.

Observational study � Prospective � One cohort

Primary outcomes

SAP � Decrease after induction of spinal anaesthesia, prior to delivery

SAP, HR, SVR, SV, CO � Change during contractions in each labour stage � Change during contractions across labour stages � Change in baseline values across labour stages

Secondary outcomes

HR, SVR, SV, CO � Change after induction of spinal anaesthesia, prior to delivery

Umbilical cord blood gas values Apgar scores after delivery

Monitoring technique

Continuous minimally invasive haemodynamic monitoring by LiDCOplus

Continuous minimally invasive haemodynamic monitoring by LiDCOplus

Main data material

Repeated haemodynamic measurements � Analysis period of 13 minutes � Mean number of beat-by-beat measurements per variable per parturient in final dataset: 1200

Repeated haemodynamic measurements � Mean monitoring period of 6 h � Mean number of beat-by-beat measurements per variable per parturient in final dataset: 3100

Main statistical analysis

Linear mixed model � Analysis of continuous changes as a function of time, modified for non-linearity

Marginal linear model � Analysis of continuous changes within strata (baseline, min, max) across labour stages

Other statistical analyses

One-way ANOVA and pairwise t-test, Kruskal-Wallis and pairwise Mann-Whitney U test, Pearson’s χ2 test

Pairwise t-test, Kruskal-Wallis test, Pearson’s χ2 test

Page 27: Haemodynamics during Vaginal and Caesarean Delivery in

23

4.2 Study Population

The target populations of our studies were healthy pregnant women at term, carrying a single

healthy foetus that was planned to be delivered by elective CD (Study I) or spontaneous VD

(Study II).

The sample size calculation for Study I is described in Paper I. Study II was performed in a

convenience sample of 20 parturients. To ensure adequate power before the study start, we

estimated the sample size needed for a paired-means test, based on the assumption that the

changes during contractions in our sample might be half as pronounced as the changes

observed in a previous case report.49 For changes during contractions, an assumed

difference in CO of 25% (1.5 l/min, SD 1.5) from baseline gave an effect size of 1.0. With an

α-level of 0.05, a power level of 95% could be achieved with a sample size of 13 parturients.

For the comparison of baselines, a difference of 10% in CO (0.6 l/min, SD 0.7) was

considered clinically interesting. With the resulting effect size of 0.85, and an α-level of 0.05, a

power level of 95% could be achieved with a sample size of 17 parturients. The same

algorithms were applied for each of the other haemodynamic outcomes, and similar or lower

required sample sizes were found. We recruited the intended group size of 20 to compensate

for possible dropouts.

The samples were obtained at regional health care institutions with broad demographic

coverage in Oslo and surroundings. Participants for Study I were informed and recruited a

few weeks prior to their scheduled CD, in the context of routine anaesthesiologic consultation

before elective surgery. Inclusion and exclusion criteria were checked; parity status was not

considered. Most of the participants were operated on the originally planned date. Scheduled

participants who were operated on an earlier than the planned date due to the onset of

labour, were not included. Participants for Study II were recruited when they arrived at the

labour ward in active labour. Study inclusion was performed at any time of the day. All eligible

parous and nulliparous women were asked to participate, but only one parturient at a time

could be included.

4.3 Ethical Approval Both studies were approved by the Regional Committee for Medical and Health Research

Ethics of Southern Norway, and by the Data Inspectorate at Oslo University Hospital. Study I,

a clinical trial testing medical treatment, was also approved by the Norwegian Medicines

Agency, and registered before patient enrolment with the European Union Drug Regulating

Authorities Clinical Trials (EudraCT) database and ClinicalTrials.gov.

Both studies were conducted according to Good Clinical Trial Practice and the principles of

the Declaration of Helsinki. Participants in both studies gave written consent after thorough

oral and written information, prior to their inclusion, and were allowed to withdraw / resign

from participation at any time before, during, and after the study.

Page 28: Haemodynamics during Vaginal and Caesarean Delivery in

24

All study data were de-identified immediately after inclusion of each participant, and stored

separately from identifying personal patient information. The collected data was accessible

for, and handled by, the investigating research team exclusively.

4.4 Main Haemodynamic Monitoring Method Continuous haemodynamic measurements were performed with the LiDCOplus monitor

(LiDCO Ltd., Cambridge, United Kingdom).91 This is a minimally invasive device able to

monitor several haemodynamic variables via a peripheral arterial cannula. The technology is

based on pulse power analysis.92 A primary algorithm, PulseCO, continuously calculates

beat-to-beat SV by analysing the arterial waveform.93 PulseCO assumes that the input of a

mass of blood and the subsequent loss of a mass of blood to the periphery result in a net

power change per heartbeat. The employed autocorrelation is a time-based method; in

contrast to Fourier analysis, it avoids a frequency approach and thus limits the effects of

arterial damping. PulseCO is coupled to a secondary algorithm, LiDCO. The latter uses a

single-point lithium indicator dilution system to measure absolute SV, after peripheral

intravenous injection of a small single dose of lithium chloride. This absolute SV value is used

for calibration of the PulseCO. The LiDCOplus derives beat-to-beat blood pressure, HR, SV,

CO, SVR, as well as cardiac index, systemic vascular resistance index, and oxygen delivery

from the arterial curve.

4.5 Data Material Studies I and II consist of two datasets each: one with demographic and single-value clinical

characteristics, and one with a large number of longitudinally measured haemodynamic data.

Haemodynamic measurements were registered by the LiDCOplus monitor, and downloaded

both as visual ‘.lvu’ files and as ‘.csv’ text files for each parturient.

The haemodynamic raw data for 120 parturients in Study I consist of approximately 3.6

million repeated beat-by-beat measurements in total, 6,000 per haemodynamic variable per

parturient. Haemodynamic analyses were run for the first 13 minutes, which equaled the

shortest interval from induction of spinal anaesthesia to delivery, and permitted to capture the

rapid haemodynamic changes after spinal induction while avoiding the artefacts that delivery,

subsequent movement, and uterotonic medication may create. The data for this analysis

period in the 112 included parturients consist of approximately 655,000 beat-by-beat

measurements in total, i.e. 1,200 per haemodynamic variable per parturient.

The haemodynamic raw data for the entire course of labour in the 20 included parturients in

Study II consist of more than 1.8 million repeated beat-by-beat measurements in total.

Haemodynamic analyses were run for baselines, and for minima and maxima during

contractions that were measured in tilted supine or dorsal lithotomy positions, and that were

undisturbed by maternal activities, medical procedures, or obvious noise. The processed

dataset, after, according to the criteria described below, cleansing and extraction of analysis

Page 29: Haemodynamics during Vaginal and Caesarean Delivery in

25

periods, consists of approximately 311,000 beat-by-beat measurements in total, on average

3,100 per haemodynamic variable per parturient.

Preparing the datasets for statistical analysis was a very time-consuming process. Several

rounds of meticulous manual review of the vast amount of measurements were necessary for

definition of analysis periods and cleansing of raw data, prior to final analysis by mathematical

and statistical software. LiDCOview PRO software (LiDCO Ltd.) was used for inspection of

‘.lvu’ files, and Excel version 14.3.2 (Microsoft, Redmond, WA) was used for examination and

processing of ‘.csv’ files.

Individual ‘.lvu.’ files, ‘.csv’ files, and case report forms of each participant were scrutinized

parallel to one another, to ensure that all relevant events (administration of medicines,

changes of position, e.g.) had been registered electronically, with correct coding for type and

point of time.

The individual datasets were then re-examined to identify extreme values and outliers.

Extreme values often occur blockwise, as a result of wire vacillation or arterial line

obstruction.94 The LiDCOplus monitor automatically identifies the majority of such corrupted

records, and labels them as ‘bad status’. Thorough manual review of the entire dataset was,

however, necessary to identify unrecognized values outside any reasonable range. In the

event of frequent or prolonged periods with extreme values, exclusion of the entire case due

to low data reliability had to be considered (at this stage). For this first, crude cleanse, cut-off

limits were set for CO at <2 and >20 l/min, for HR at >200 beats/min, for SVRI at >6000

dynes/s/cm5, and in Study II for SAP at <60 mmHg, wide enough to ensure that only clearly

corrupted records would be excluded.

Another review of all individual files was dedicated to identifying single-point values with

sharp deviation from the adjacent beat-to-beat values. Such artefacts may be caused by, e.g.,

extra or skipped heartbeats, or sudden movements.94 The cut-off limits were set individually

for each patient file, based on clinical discretion.

In Study I, these cleansing steps were performed using MATLAB version R2013a (The

MathWorks, Natick, MA). Remaining artefacts were eliminated by running an artefact removal

algorithm described by Deegan et al.,95 and were replaced using nonlinear interpolation. The

uneven sampled beat-to-beat dataset was transformed into sliding averages with a window

size of ten seconds and a slide of five seconds. The purposes of this transformation were

smoothing the data and reducing the number of observations for a given period of time. After

completion of the cleansing and transformation processes, the final dataset was read into the

statistical software, and the randomisation codes were released by the hospital pharmacy.

Individual traces were merged into one summarising graph per treatment group, and group

comparisons were performed using linear mixed models.

Page 30: Haemodynamics during Vaginal and Caesarean Delivery in

26

In Study II, cleansing was performed using Excel software. The final dataset was constructed

by extraction of repeated individual baseline values from each stage, and repeated individual

minima / maxima during contractions from each stage, based on the criteria described in the

data analysis section in Paper II. Summary measures were calculated in Excel, and the final

dataset was read into the statistical software for analysis of haemodynamic changes during

the different stages of labour by marginal linear models.

4.6 Statistical Models Descriptive data were analysed with appropriate tests for single-point comparisons (1-way

ANOVA and pairwise t-test, Kruskal-Wallis and pairwise Mann-Whitney U test, Pearson’s χ2

test) in SPSS (Version 22.0; IBM Corp Armonk, NY, USA) in both studies.

Haemodynamic data were analysed with a linear mixed model (SPSS) in Study I, and with a

marginal linear model (Stata Statistical Software: Release 14; StataCorp. 2015, College

Station, TX, USA) in Study II.

The linear mixed model was used for analysis of continuous changes in haemodynamic

variables as a function of time, with treatment groups as fixed factors. Baseline differences

were adjusted for by excluding the main effect of the group from the model. The dynamism in

haemodynamic trends was accounted for by introducing a quadratic effect of time

(uncentred). Dependencies in the data and inhomogeneous variances among the groups

were handled by introducing a random intercept and a random effect of time. Adjustment for

multiple between-group comparisons was handled ad modum Bonferroni.

The marginal linear model was used to assess haemodynamic changes across stages, by

strata (baseline, minimum, maximum). Stage, parity, epidural analgesia, and oxytocin infusion

were treated as fixed factors; epidural and oxytocin infusion could vary within parturients

during the course of labour. Within-subject correlation was allowed for by using the robust

variance estimator for estimation of standard errors. Sensitivity analyses were performed by

running the same marginal linear models without adjusting for any factors other than stage.

Page 31: Haemodynamics during Vaginal and Caesarean Delivery in

27

5 SYNOPSIS OF RESULTS

Figure 1 shows patient numbers and group allocation in Study I.

Figure 1. Flow Chart Study I

For Study II, the logistic organisation of study inclusion prevented identification of the total

number of eligible parturients during the enrolment period. Non-inclusion of parturients

assessed for eligibility was mainly due to either latent, advanced, or induced labour.

Approximately one third of the eligible parturients that were informed about the study declined

taking part, because of reservations against participation in research projects or against

arterial cannulation during labour. Of the 20 included parturients, 19 were followed until the

early postpartum period, and one was lost to follow-up during late stage 1 because of

obstetric indication for caesarean delivery.

Page 32: Haemodynamics during Vaginal and Caesarean Delivery in

28

5.1 Results of Study I

1. SAP was highest in the phenylephrine group (phe), with

• less continuous SAP decrease than in leg (p =0.013) and control (p<0.001)

• less maximal SAP decrease than in leg (p =0.031) and control (p <0.001)

• shorter duration of decreasing trend in SAP than in leg and control

• lower incidence of hypotension than in control (p =0.016).

SAP was higher in the leg wrapping group (leg) than in the control group (control), with

• less continuous SAP decrease than in control (p <0.001).

2. All groups had a rapid decrease in SVR, and a rapid increase in SV, HR, and CO. The

respective initial changes were followed by a gradual inverse trend. Comparing groups,

• continuous SVR was higher in phe than in leg (p <0.001) and control (p <0.001)

• continuous SV was higher in phe (p =0.001) and leg (p <0.001) than in control

• continuous HR was lower in phe than in leg (p = 0.002) and control (p = 0.002)

• continuous CO was lower in phe (p < 0.001) and control (p = 0.001) than in leg.

3. There was no reactive hypertension in any of the groups. The incidence of bradycardic

episodes was lower in phe (2.6%) than in leg (5.3%) and control (8.3%), but the

difference was not statistically significant. Maximal decrease in CO was 5% below

baseline in phe and similar between groups (p = 0.72).

4. Apgar and umbilical blood gas values were within normal range and without significant

between-group differences, except for lower umbilical artery lactate in phe (2.2 mmol/l)

than in control (2.6 mmol/l; p = 0.007), and lower umbilical vein lactate in phe (1.75

mmol/l) than in leg (1.9 mmol/l; p = 0.035) and control (2.1 mmol/l; p <0.001).

Figure 2. Continuous SAP during 13 minutes after spinal anaesthesia for CD, Study I

Page 33: Haemodynamics during Vaginal and Caesarean Delivery in

29

Figure 3. Continuous SVR during 13 minutes after spinal anaesthesia for CD, Study I

Figure 4. Continuous SV during 13 minutes after spinal anaesthesia for CD, Study I

Figure 5. Continuous CO during 13 minutes after spinal anaesthesia for CD, Study I

More detailed results are presented in Paper I, and in the appendix.

Page 34: Haemodynamics during Vaginal and Caesarean Delivery in

30

5.2 Results of Study II

5. Haemodynamic changes during contractions were profound in all labour stages. The

primary change was followed by a short inverse change before baseline was restored.

Percentages below are mean maximum changes for the entire cohort.

During stage 1 contractions, the primary direction of changes varied between parturients.

Compared to stage 1 baseline values,

• SAP increased in all parturients; maximum increase: 25% (from 136 to 171 mmHg);

• HR increased in all parturients; maximum increase: 39% (from 83 to 115 beats/min);

• SVR increased in most parturients, but decreased in some; maximum increase: 24%;

• SV decreased in most parturients, but increased in some; maximum decrease: 18%;

• CO increased in most parturients, but decreased in some; maximum increase: 52%.

During the peak of stage 2 contractions, the direction of changes was the same in all

parturients. Compared with stage 2 baseline values,

• SAP increased by 36% (from 136 mmHg to 185 mmHg);

• HR increased by 52% (from 86 beats/min to 131 beats/min);

• SVR increased by 88% (from 1124 dynes/s/cm5 to 2110 dynes/s/cm5);

• SV decreased by 44% (from 77 ml to 43 ml);

• CO decreased by 32% (from 6.6 l/min to 4.5 l/min).

6. The extent of haemodynamic changes during contractions increased along the course of

labour, and was greatest in stage 2 and during delivery.

7. Baseline values were similar throughout labour, and postpartum, for all haemodynamic

variables.

8. The effects of epidural analgesia were minimal and non-significant for all haemodynamic

variables.

Page 35: Haemodynamics during Vaginal and Caesarean Delivery in

31

Figure 6. Haemodynamic changes during labour, representative trace Extract from late stage 1 (flags 42-50), stage 2 (flags 78-87) with delivery (flags 88-99), and early

postpartum stage in one of the parturients.

Figure 7. Haemodynamic changes during labour, representative trace. Extract from stage 2 (flags 23-47) with delivery (flags 48-59), and early postpartum stage in one of the

parturients, in the right panel of the figure. In the left panel of the figure, flags 40-46 from the right panel are

displayed in enlarged view.

More detailed results are presented in Paper II, and in the appendix.

Page 36: Haemodynamics during Vaginal and Caesarean Delivery in

32

6 METHODOLOGICAL CONSIDERATIONS

6.1 Basic Methodological Characteristics Both studies examined the haemodynamic variables SAP, SVR, SV, HR, and CO in healthy

parturients at term, using the minimally invasive monitoring method LiDCOplus, which

resulted in large datasets with an excessive amount of longitudinal measurements. However,

different modes of delivery and outcomes of interest in the two studies required unlike

designs. For the comparison of possibly minor haemodynamic differences between three

treatment arms in Study I, a large sample size and randomised, controlled double-blind

design were chosen. For demonstration of profound haemodynamic changes from baseline

during contractions in one cohort in Study II, a smaller sample size and prospective

observational design were appropriate.

Since CD is relatively quick and follows a consistent sequence of events, the measurement

period per participant in Study I was rather short (around one hour), and a predefined

identical time interval was analysed in all parturients. By contrast, duration of labour and VD

is less predictable, and may take many hours. In Study II, the measurement period per

participant was hence longer (mean six hours), and varied between parturients (range of

between two and 15 hours); data for analysis were extracted from a different number of time

intervals for each parturient.

6.2 Study Population

The majority of participants in both studies were of Caucasian Norwegian origin. Apart from

slight differences in age and body height, descriptive characteristics in both samples are

similar to previous studies cited in our papers. Due to minor anatomical or physiological

variations, the incidence of spinal hypotension, the haemodynamic reaction to prophylactic

methods, and haemodynamics during labour might differ slightly between ethnic populations.

We are, however, not aware of any major factors related to the composition of our study

population that would limit the generalisability of our findings to the target population of

healthy pregnant women at term in Norway, Europe, or on different continents.

The fact that participants were recruited a few weeks prior to inclusion in Study I allowed the

parturients time for taking their decisions, and facilitated smooth preparation and logistic

organisation of their study enrolment.

In Study II, direct succession of recruitment and inclusion in the study demanded a quick

decision from the parturients, when active labour had started. This, and the uncertain duration

of labour for each participant posed considerable logistic challenges to the investigator. A

high number of parturients who did not meet inclusion criteria (predominantly because of

advanced or induced labour), declined participation (mainly because of reservations against

arterial cannulation or against taking part in research projects), or had exclusion criteria (pre-

existing disease, or language problems preventing informed consent) led to a great deal of

Page 37: Haemodynamics during Vaginal and Caesarean Delivery in

33

time spent in the labour wards without successful inclusion of participants. Advance

recruitment might have been desirable, both for participants and investigator, but would have

required dayround availability of study staff, as it is impossible to predict the exact onset of

spontaneous labour.

6.3 Ethical Aspects In both studies, the use of minimally invasive monitoring required radial artery cannulation.

This procedure may cause transient local pain, and potential complications include

haemorrhage, nerve injury, local infection, and permanent ischaemic damage due to arterial

injury or thrombosis. The overall risk of these complications is, however, very low, and arterial

line placement is generally considered safe. Benefits of an arterial line include increased

patient safety through continuous haemodynamic monitoring, and the possibility for taking

multiple blood samples without the need for repeated vascular puncture.96 In all participants,

contraindications for arterial line placement (e.g. signs of inadequate blood circulation to the

hand, local injuries, anticoagulation, and history of conditions that increase the risk of

thrombosis or impaired vascular flow such as Raynaud’s syndrome or thromboangiitis

obliterans) were excluded before the procedure was carried out.

Receiving no specific prophylaxis against spinal hypotension, the control group in Study I was

likely to develop a high incidence of spinal hypotension. However, continuous invasive blood

pressure monitoring and a strict rescue pressor protocol ensured immediate identification and

treatment of hypotension. In view of heterogeneous clinical practice with regards to

monitoring intervals and prophylactic interventions,25,26 we considered a pure placebo group

as justifiable in our study.

With continuous haemodynamic monitoring and constant presence of the investigating

anaesthesiologist, participants in both studies had closer clinical follow-up during their CD or

during labour, respectively, than non-participants.

6.4 Main Haemodynamic Monitoring Method

Choice of technology

We used the LiDCOplus monitor, because it is currently the only minimally invasive device

that provides calibrated continuous data, and is valid in detecting rapid changes in

haemodynamic trends.53 LiDCOplus is considered an appropriate device for obstetric

anaesthesiologic research,53,56,57,97 and has been used in several recent studies in obstetric

patients.19,32,94,97,98 Its reliability has been validated also in the setting of changing SVR,99,100

and its accuracy has been shown to be similar to pulmonary arterial catheter measurements

in pre-eclamptic parturients.97 An editorial claiming limited reliability of the LiDCOplus during

rapidly changing haemodynamics101 was based on the misconception that the method

depends on pulse contour analysis using the Fourier principle. In fact, LiDCOplus employs

pulse power analysis, which is a much more robust algorithm.92

Page 38: Haemodynamics during Vaginal and Caesarean Delivery in

34

Alternative haemodynamic monitoring techniques include both invasive and non-invasive

devices with different features. LiDCOrapid is an advanced version of PulseCO, with high

trending reliability but limited accuracy due to the lack of proper calibration.53,102

Flotrac/Vigileo (Edwards Lifesciences, Irvine, California, USA) is a minimally invasive method

based on pulse contour analysis. Its algorithm does not provide true continuous real-time

data, its accuracy is limited due to lacking the possibility for proper calibration, and its

reliability in tracking changes is restricted, particularly in settings with rapid changes in

SVR.53,57,102-105 PiCCO (Pulsion Medical Systems, Munich, Germany) and pulmonary artery

catheters are highly accurate, but do not provide continuous monitoring, and due to their

invasiveness and the related discomfort and higher risk of complications,53,57,106 they are not

an option for research in healthy parturients.

Among non-invasive monitoring methods, echocardiography is inappropriate for continuous

monitoring. Suprasternal (SupraQ Cardiac Function Monitor, Deltex Medical Limited,

Chichester, UK; USCOM Ultrasonic Cardiac Output Monitor, USCOM Limited, Sydney, New

South Wales, Australia) and transoesophageal (CardioQ-ODM, Deltex Medical Limited,

Chichester, Sussex, UK) aortic Doppler velocimetry devices provide beat-to-beat records of

several haemodynamic variables and have been used in obstetric studies, but there are

concerns about limited measurement accuracy and inter-observer variability.53,107,108 In

addition, the suprasternal techniques are unsuitable for continuous use, and

transoesophageal monitoring requires sedation or general anaesthesia.56 The accuracy of

devices based on transthoracic or whole-body electrical resistance, i.e. classical bio-

impedance, electrical cardiometry or electrical velocimetry (ICON and AESCULON Systems,

Osypka Medical GmbH, Berlin, Germany) and bio-reactance (NICOM, Cheetah Medical,

Portland, Oregon, USA), is limited, as is their ability to track rapidly changing

trends.53,102,103,109,110 Moreover, the reliability of these devices is rather easily affected by

diathermy, surgical manipulation, changes in peripheral vascular resistance, or patient

position. Modelflow via finger-cuff plethysmography (Finometer and Portapres, Finapres

Medical Systems, Amsterdam, the Netherlands) provides convenient beat-by-beat monitoring,

but accuracy and precision are limited, particularly during changes in SVR, body temperature,

or volume state.56,111

Limitations of LiDCOplus

Reliability may be reduced during highly irregular arterial rate56 and treatment with muscle

relaxants or lithium,92 but none of these factors pertained to any of our participants.

Because of possible minor drift in terms of accurate interpretation of absolute stroke volume,

recalibration of the LiDCO device every 8 to 12 hours is recommended.91,92 Recalibration

during advanced labour with frequent contractions and constantly shifting haemodynamics

might be unreliable, and was therefore not carried out. In participants with longer duration of

labour in Study II, measured stroke volume might thus differ slightly from the true absolute

Page 39: Haemodynamics during Vaginal and Caesarean Delivery in

35

values. Since drift is unidirectional, this would not affect the extent of haemodynamic changes

during contractions. Labour went on for more than eight hours in five parturients, and the

mean duration of labour was below the recommended recalibration interval; thus the reliability

of baseline measurements across stages should not be significantly diminished either. In

Study I, the monitoring period was less than two hours per parturient.

LiDCO traces may be disturbed by movement, or kinking of the arterial line.91,92 Outliers and

artefacts were much more frequent during labour in Study II, due to significant movement or

valsalva effort, than in the relatively calm setting of elective CD in Study I. Parturients were

continuously encouraged to keep their body as still as possible and their upper limb relaxed,

during as many contractions as possible, also under bearing-down effort during stage 2 and

delivery, and postpartum. Most parturients managed this generally well, but did move or

clench their hands during a number of contractions. Artefacted measurements were not

included in the final dataset.

6.5 Analysis and Presentation of Data Preparing the haemodynamic datasets for statistical testing was the most time-consuming

part of the data analysis in both studies. To ensure high reliability of the final datasets, each

of the extensive raw data files was reviewed meticulously several times, for stepwise

cleansing of artefacts by different criteria, and for data extraction.

Analysis period

The analysis period in Study I was a single continuous interval, with a relatively narrow time

window from spinal induction to delivery of the newborn. In Study II, data extraction was

complex, owing to long-lasting heterogeneous progression of labour, varying frequency and

duration of contractions, changes of position, and noise during movement and obstetric

procedures. Because of different cervical dilatation at study inclusion, the starting point for

haemodynamic analyses varied between parturients. The total analysis period included data

from multiple time intervals, the amount of which also varied between parturients. These time

aspects affected the choice of statistical models for Studies I and II.

Statistics

Analysis of the vast longitudinal haemodynamic datasets required advanced statistical

models in both studies. Statisticians with expertise in the field of repeated measurements

therefore advised us on the choice, execution, and interpretation of the respective appropriate

models.

Both the linear mixed model and the marginal linear model are extensions of ordinary linear

regression that are suited to dealing with complex longitudinal data.

We chose the linear mixed model for Study I because it allows correlation of observations

within subjects, and between clustered subjects, even in the case of changing variability. The

Page 40: Haemodynamics during Vaginal and Caesarean Delivery in

36

model also permits varying intra- and inter-individual spacing of measurements by flexible,

regression-based handling of time,112-115 and allows modelling of more than one error term by

inclusion of both fixed and random effects.112,114 Fixed effects are caused by explanatory

variables that have systematic predictable influence on the outcome,115 such as treatment

group. Random effects arise from non-systematic, unpredictable causes.115 The additional

flexibility requires complex specifications to be incorporated,112 and the relevant details of our

model are described in Paper I and section 4.6. Adjustment for multiple group comparisons is

generally recommended, and in view of the relatively low number of group comparisons, we

considered the Bonferroni correction as appropriate.116,117 Adjustment for multiple testing of

several outcome variables is controversial116,117 and was not performed.

In general, the marginal linear model is less flexible than the linear mixed model, but also less

complex, and thus suitable for analysis of unclustered longitudinal data114 as in Study II. Like

the linear mixed model, the marginal linear model accounts for correlation of repeated

observations within subjects and assumes independency between subjects. It also allows for

a different number of repeated observations per subject, but does not require fixed starting

points nor identical analysis periods in all subjects. Since inter-parturient heterogeneity in

timing and amount of measurements per labour stage precluded the use of a common time

axis for analyses, we categorized the observations according to cervical dilatation and stages

in Study II. The detailed specifications incorporated in the model are described in Paper II and

section 4.6. Study II was not primarily designed for comparison between parturients with and

without epidural analgesia, but approximately half of the 1,366 summary measures per

haemodynamic variable in the final dataset were from observations with epidural analgesia.

For parturients with epidural analgesia, the dataset includes observations of haemodynamic

data prior to initiation of epidural analgesia. Hence, assessment of epidural analgesia as an

independent factor in the marginal linear models was feasible. To study the impact of epidural

analgesia as a possible modifying or confounding factor, sensitivity analyses were carried out

by running the same model without epidural analgesia as an independent factor.

Presentation of results

The different structure of analysis periods offered different options for presentation of results

in the two studies. Merging individual traces into one summarising graph was suitable for the

13-minute period analysed for all parturients in Study I. A merged graph would not have been

meaningful in Study II, because duration of labour stages, and duration and frequency of

contractions varied considerably within and between parturients. A graph based on

interpolation of summary measures would not have provided any additional information to the

presented tables. Instead, we present extracts from representative raw data traces, which we

believe are a useful visual supplement from a clinical perspective. These extracts do not

reflect overall group values, but they illustrate the typical, verbally described haemodynamic

changes, and provide an intuitive clinical impression of maternal haemodynamics during the

different stages of labour.

Page 41: Haemodynamics during Vaginal and Caesarean Delivery in

37

6.6 Validity Validity reflects how closely a given inference approximates the truth. In science, this may

only be achieved if the chosen measures, design, and samples are appropriate for answering

a particular research question.118

The internal validity of a study reflects whether derived conclusions on causal relationship

between tested factors and observed effects in the study population are adequate.118 To

maximise internal validity, systematic and random errors need to be minimised.119

Systematic error, also called bias, describes measurement inaccuracy into one consistent

direction due to flaws that persist throughout the entire experiment.120 Such flaws may occur

during different stages of a study, and should be limited by thorough planning.119 Systematic

errors are generally divided into the three main categories of selection bias, information bias,

and confounding. They may be sub-classified by different criteria. Different types of studies

are prone to different main- and subtypes of systematic errors.119 Systematic errors with

relevance for our studies will be considered in the following section.

Random error is the term for variability in measurements from unknown and unpredictable

causes, such as limited precision of measuring instruments, or changes in the environment

that are beyond the control of the investigator. This type of measurement inaccuracy varies in

size and direction, corresponding to normal distribution, when repeating the measurement.121

Hence, random error decreases with increasing sample size, and can be estimated by

statistical analysis. Common measures of random error include standard deviation and

confidence intervals.120

The external validity of a study reflects the applicability of conclusions from the study

population to the relevant target population,122 as well as to a broader population or to

different settings.118 Internal validity, adequate composition of the study sample by

appropriate inclusion and exclusion criteria, suitable study setting and timing, and avoidance

of certain types of systematic errors, all are imperative for external validity.122

Internal Validity in Study I and II

Selection bias

Selection bias occurs when a study sample or group is not representative of the target

population.119 As discussed under point 6.2, we think that our samples correspond reasonably

well to our target population.

In Study I, selection bias between treatment groups was minimised by randomisation.

Concerning Study II, we assume that the somewhat heterogeneous haemodynamic changes

mirror actual pathophysiologic diversity between parturients, but a much larger sample would

be needed to exclude the possibility that selection bias contributed to the observed variability.

Apart from that, inferences regarding effects of epidural analgesia might be biased if

Page 42: Haemodynamics during Vaginal and Caesarean Delivery in

38

parturients requesting epidural analgesia were systematically different from those wishing to

cope without analgesic treatment.

In Study I, we excluded eight participants. In view of the low number of excluded cases

compared to the total number of participants in each group, and of the reasons for their

exclusion, bias created by exclusion of cases should not be relevant. Case exclusions were

performed before breaking the randomisation codes. Study I had no loss to follow-up. In

Study II, owing to varying cervical dilatation at study inclusion, the number of participants in

early stage 1 was slightly lower than during the later stages. For one participant who needed

CD, only stage 1 measurements are included. The total number of longitudinal measurements

was high enough for valid statistical analysis, and marginal linear models allow for a varying

number of observed subjects per stage.

Information bias – General

Information bias may arise from various pitfalls during data collection. One frequent subtype

is misclassification bias, caused by incorrect classification of exposure, or by flawed detection

of effects.119 The general risk of detection bias was minimised in both studies by using a

validated and observer-independent technique for continuous minimally invasive

haemodynamic monitoring. In Study I, the general risk of detection bias was further minimised

by double-blind controlled design. Specific limitations of the employed monitoring technique,

and other possible sources of misclassification, are discussed below.

Information bias – Validity and Reliability of Measurements

The accuracy of LiDCOplus is similar to pulmonary arterial catheter measurements.97

Pulmonary arterial catheter, which is considered the gold standard device for haemodynamic

measurements, has an approximate accuracy of 10% to 20%.56 Thus, a minor degree of

uncertainty remains concerning the proximity of measured to true values. Correct calibration

of the pressure transducer inside the arterial cannula is a prerequisite for accurate LiDCO

measurements, and was therefore performed with great care in both studies.

LiDCOplus has shown high precision in following trends.53,91,97 As discussed in section 6.4,

we assume that effects of possible drift are negligible in both studies.

LiDCOplus has been validated for use in rapidly changing haemodynamic conditions and in

obstetric patients,53,56,97,100 but has not been used for studies during labour so far. In Study II,

the device provided apparently undisturbed traces even during intense contractions and

physical effort, but in some parturients, a number of measurements during the peak of

bearing-down effort were obviously compromised and thus excluded. Simultaneous use of

LiDCOplus, peripheral artery Doppler and Doppler echocardiography might help to distinguish

effects of peripheral vasoconstriction from compromised cardiac output during bearing down.

Page 43: Haemodynamics during Vaginal and Caesarean Delivery in

39

Stage 2 baselines were analysed until the period immediately prior to delivery. Baseline

values during delivery were not analysed, because pauses between delivery contractions

were too short to achieve repeated stable baseline readings. Delivery comprises the last few

contractions leading to parturition of the newborn, i.e. a short time span only.

In the cases where arterial pressure traces were artefacted during the peaks of delivery

contractions, undisturbed arterial curves and stable LiDCO readings reappeared immediately

after the last bearing-down effort. Thus, analysis of postpartum data was considered valid,

and inclusion of repeatedly measured postpartum baseline values was performed according

to the same criteria as for stage 1 and stage 2 baselines.

Blood gas values were measured with the same calibrated instruments, and within a time

frame of three years and of one year in the respective studies, thus laboratory variation

should not be of major concern.

Information bias – Missing values

Haemodynamic analyses are exclusively based on measurements that were defined as

reliable. As described under 4.5, 6.5 and in Paper II, the dataset was cleansed from corrupted

values, during significant movement or maximal expulsive effort during delivery in Study II, for

instance. The true haemodynamic changes from baseline during corrupted, hence excluded,

peak segments of stage 2 contractions are unknown (i.e. missing), and might thus either be

similar, or more significant, or less significant than the adjacent included measurements. The

latter seems improbable, in view of the considerable changes prior to, and the increased

physical strain during, maximal expulsive effort. We assume that the presented mean

maximum changes during stage 2 and delivery might underestimate the true mean maximum

changes to some degree.

We did not measure haemodynamic baselines prior to the onset of labour in Study II. Pre-

labour baselines might be different from baseline measurements during labour and

postpartum. The aim of Study II was the assessment of haemodynamic changes after the

onset of active labour, hence pre-labour baselines were not relevant.

A considerable number of missing values may limit valid interpretation of umbilical cord blood

gas values in both studies. The missing values are mainly due to an insufficient amount of

blood in several samples, which in turn may be caused by blood wastage during manipulation

of the umbilical cord, or by coagulation before blood aspiration was attempted. The amount of

missing values differed considerably between groups in Study I, and between nulliparous and

parous in Study II, but we cannot draw any conclusions on whether this is due to coincidence

or to any specific factors.

Information bias – Observer variation

As described above, haemodynamic measurements with LiDCOplus are observer-

independent. In Study I, calculation of cut-off limits for rescue pressor boluses and continuous

Page 44: Haemodynamics during Vaginal and Caesarean Delivery in

40

registration of relevant events (rescue pressor, nausea, delivery) into the LiDCO device and

the case report form followed a standardised instruction. The same investigator and the same

scientific assistant followed all participants, and ensured consistent adherence to the study

protocol. In Study II, one single investigator followed all participants, without a scientific

assistant. The labour setting sometimes posed logistic challenges, particularly in parturients

with high levels of pain and stress. Therefore, the risk for missing registration of individual

events was higher than in Study I. Contractions were registered manually into the LiDCO

device, based on the tocometry report by the midwife. Accuracy in reporting the onset of

contractions might have varied between the respective midwives. This kind of observer

variation, and the absence of the possibility for correlation of uterine pressure and

haemodynamic values, introduce some uncertainty with regard to the timing of

haemodynamic changes during contractions. This potential source of error could have been

avoided, if synchronised tocometry had been part of our study data.

Data were cleansed following clear and predefined criteria, as described under 4.5, and in

Papers I and II. The final step of cleansing individual artefacts was performed by clinical

discretion, and in spite of high concentration and meticulous work, a minor risk of missing

individual artefacts or excluding some non-artefacted values remains.

Data of both studies were analysed with advanced statistical models, according to the advice

of experts in the field of complex repeated measurements. The appropriateness of analyses

and quality of results were verified by the same experts.

Information bias – Flawed detection of treatment effect

In Study II, incorrect assessment of volume status or efficiency of epidural analgesia was

theoretically possible. In that case, identification of effects caused by epidural analgesia or

oxytocin infusion might be thwarted. We consider it improbable that major error was

introduced by this potential source of misclassification or detection bias, but, as expounded in

section 7.2, our study design prohibits definite conclusions about the haemodynamic effects

of epidural analgesia in any case.

Confounding and effect modification

In Study I, the risk of confounding was limited by randomisation, and a strict study protocol

that avoided variation with regards to exposure (rescue pressor, for instance).

As Study II examined parturients presenting for spontaneous delivery, a certain heterogeneity

with regards to duration of labour and exposure (mobilisation, oral intake, epidural analgesia,

oxytocin infusion, and obstetric procedures) could not be eliminated. In order to reduce

confounding from these elements, only measurements taken in tilted supine or dorsal

lithotomy position, in the absence of significant movement and obstetric or other procedures,

were included in the final dataset. In order to detect possible effect modification, we included

epidural analgesia, oxytocin infusion, and parity as factors in the statistical analysis, and ran

additional sensitivity analyses for these factors.

Page 45: Haemodynamics during Vaginal and Caesarean Delivery in

41

Differences between findings in Study II and findings in previous haemodynamic studies

during labour might partly be due to insufficient internal validity in the former studies, owing to

confounders or to the use of unreliable and intermittent monitoring methods;

pathophysiological variability between parturients presumably also plays a role (see section

7.2). However, it is impossible to exclude that undetected confounders might exist in Study II.

Large and complex studies would be needed to definitely answer these questions.

Random errors

Random errors are less likely in large samples such as in Study I than in small samples such

as in Study II. As measures of uncertainty, standard deviation and confidence intervals help

to evaluate random error in a sample. Narrow confidence intervals indicate high precision of

estimates. Low standard deviations suggest little variation.120 Confidence intervals and

standard deviations are displayed in the result tables for each study.

External Validity

As discussed in section 6.2, we think that participants in both our studies represent the target

population of healthy parturients around term reasonably well. Subject to internal validity, our

findings should hence be generalisable to healthy parturients outside of our study. We did not

measure socio-demographic characteristics in our parturients, but it seems unlikely that

possible participation bias would have a major influence on haemodynamic outcomes.

However, selection bias is hard to measure, and some uncertainty may remain.

Page 46: Haemodynamics during Vaginal and Caesarean Delivery in

42

7 DISCUSSION OF RESULTS

This Ph.D. project investigated maternal haemodynamics during caesarean delivery in Study

I, and during vaginal delivery in Study II. The project was not designed for comparison of

haemodynamics across the two studies, and does not permit any conclusions on maternal

circulation during caesarean versus vaginal delivery. Our findings are therefore discussed

separately for each study, with a summary of the respective discussion sections in Papers I

and II, and a few additional considerations.

7.1 Discussion of Study I Study I showed that an initial bolus followed by low-dose phenylephrine infusion has a better

prophylactic effect than leg wrapping against spinal hypotension during caesarean delivery.

Study I is the third study evidencing with continuous invasive monitoring that a rapid decrease

in SVR and a compensatory increase in CO are the main haemodynamic derangements

induced by spinal anaesthesia. Study I is the first trial using continuous invasive monitoring to

compare a prophylactic strategy directed at the venous side with one exerting its main effect

on the arterial side of the vascular system. The data indicate that venodilation contributes, to

a minor degree, to spinal hypotension.

Prophylactic Effect of Phenylephrine and Leg Wrapping on Blood Pressure Less continuous SAP decrease in the phenylephrine group compared with the leg wrapping

and control groups, and less mean maximal SAP decrease (-10 mmHg) as well as a lower

incidence of hypotension in the phenylephrine compared with the control group, demonstrate

that the incidence and severity of hypotension were reduced best in the phenylephrine group.

Comparing leg wrapping with control, continuous SAP decrease was significantly less, but

neither mean maximal SAP decrease (-20 mmHg versus -31 mmHg) nor the incidence of

hypotension (58% versus 75%) were significantly different. By the end of the analysis period,

group traces show a similar SAP decrease in the leg wrapping and control groups. Leg

wrapping thus had a moderate preventive effect on spinal hypotension, which is in line with

conclusions by the Cochrane Collaboration, based on seven previous studies on lower limb

compression.2 Neither our phenylephrine regimen nor leg wrapping caused reactive

hypertension, and the incidence of bradycardia was minimal in both groups. That means leg

wrapping had no advantage over low-dose phenylephrine concerning these side effects.

Study I is the first comparison of phenylephrine and lower limb compression during spinal

anaesthesia for CD. Demonstrating that the prophylactic effect of our low-dose phenylephrine

regimen is superior to leg wrapping, Study I supports phenylephrine infusion combined with

crystalloid cohydration27 as the first-line choice for prevention of spinal hypotension during

caesarean delivery. In settings where phenylephrine is not available, lower limb wrapping

may be used as an alternative means of hypotension prophylaxis.

Page 47: Haemodynamics during Vaginal and Caesarean Delivery in

43

The Phenylephrine Regimen

Our phenylephrine regimen, an initial bolus (0.25 μg/kg, i.e. median dose 20 μg, range from

15 μg to 28 μg) followed by low-dose infusion (0.25 μg/kg/min, i.e. median rate 20 μg/min),

did not completely avert the rapid vasodilation caused by spinal anaesthesia. However, it

achieved a lesser decrease in SVR, a lower incidence of hypotension, and less maximum

decrease in SAP than a previously studied regimen19 using the same continuous low-rate

infusion without an initial bolus. Quicker stabilisation of blood pressure by bolus dosage than

by continuous infusion of phenylephrine in a previous trial34 supports the addition of an initial

bolus to a low-dose infusion regimen. The bolus in that study was higher than ours (120 μg),

but administered on therapeutic instead of prophylactic indication. Since intermittent

haemodynamic monitoring may miss the peak effect of an administered bolus, the frequently

recommended bolus size of 100 μg or more34,123 might be too high. The only study that

monitored the haemodynamic effects of phenylephrine boluses continuously suggests that a

bolus of 80 μg is too large because it may lead to an intermittent overshoot in SVR with

concomitant CO depression.32 Since our bolus of 20 μg was too small to completely prevent

the initial decrease in SVR, the optimal dose for an initial bolus prior to low-dose infusion is

probably somewhere between 40 μg and 60 μg.

Reactive hypertension and baroreceptor mediated sinus bradycardia are known side effects

of phenylephrine.29 Several recent studies have attempted to optimise phenylephrine

regimens in order to avoid these adverse effects, while improving the prevention of

hypotension and related symptoms. Intermittent boluses prevent hypotension

effectively,32,34,123 but continuous infusion has been shown to stabilise blood pressure closer

to baseline, to keep the incidence of nausea lower, and to require less physician interventions

than bolus-based administration.123 High-dose phenylephrine infusions (100 μg/min to 120

μg/min), combined with cohydration, may completely avoid hypotension,68,78 but lead to high

incidences of hypertension (up to 80%) and of bradycardia (up to over 30%).78 Recent

suggestions for clinical practice include variable rate infusion regimens with a moderate start

dosage (50 µg/min or 0.75 µg/kg/min) and subsequent rate adjustment by clinically monitored

variables.27,30 From a clinical perspective, this may seem more reasonable than the rigid rates

of many trial protocols, but a perfect titration algorithm has not been reported yet. Hitherto

studied variable-rate infusions79,123 attained lower incidences of hypotension (<15%) than our

(42%) and other low- or medium-dose regimens,33,78 but caused some reactive hypertension

(6-35%).79,123 Intermittent monitoring may fail to detect rapid changes in blood pressure,54,124

hence it is possible that studies based on intermittent monitoring33,34,68,74,78,79,123

underestimated the respective incidences of hypotension and hypertension.

With an incidence of bradycardia of 2.6% and no reactive hypertension, our regimen had

fewer adverse effects than previously studied variable-rate and low- or medium-dose

infusions (incidences of hypertension of between 10% and 40% and of bradycardia of

between 8% and 15%).33,78,79,123 Based on these and our own findings, we assume that a

Page 48: Haemodynamics during Vaginal and Caesarean Delivery in

44

higher initial bolus than in our study, added to low-dose infusion or to variable-rate infusion

with a low start dosage, might help to further optimise the balance between prevention of

hypotension and avoidance of side effects.

The Leg Wrapping Technique In spite of our strict wrapping protocol, coload instead of preload, and the same definition of

hypotension as in previous studies, we were not able to reproduce the low incidence of

hypotension (15% to 18%) reported for leg wrapping groups in some of the limited number of

previous trials.37-39 In view of our strict wrapping protocol, it seems unlikely to us that the

quality of compression in our leg wrapping group might have been lower than in previous

studies. Besides, the incidence of hypotension in the control groups of previous trials was

also lower than in our control group.38,39 In the light of the rapidly changing haemodynamic

condition after spinal onset, we presume that intermittent non-invasive monitoring (with up to

five-minute intervals between measurements)39,44 in the historic studies may have missed

hypotensive episodes that continually invasive monitoring would have detected.54 In a recent

study, continuous non-invasive blood pressure monitoring revealed a 91% incidence of

hypotension during CD, whereas intermittent measurements at three-minute intervals only

detected a 55% incidence in the same patients.124

One might contemplate whether the choice of a different lower limb compression method

would have led to better haemodynamic outcomes than leg wrapping. In previous studies,

alternative techniques for lower extremity compression have shown varying success. A

sequential compression device reduced hypotension incidence from 92% to 52%,87 i.e. to a

similar incidence as in our leg wrapping group. Other studies were either not able to reduce

hypotension significantly, e.g. by inflatable boots,84 compression stockings,88 or

thromboembolic deterrent stockings,89 or the reliability of the study methods was low, e.g. in

studies on inflatable splints85 or a sequential compression device in combination with

thromboembolic deterrent stockings.86 Manual application of elastic bandages is simple and,

despite the absence of the possibility to monitor and fine-tune the exerted pressure,86,87 has

been pointed out as the most effective technique among different methods of lower limb

compression.41 In light of these findings, and of the recent insight that spinal hypotension is

mostly due to arteriolar rather than venous vasodilation,19,35 we consider it unlikely that an

alternative lower limb compression technique would have stabilised maternal blood pressure

significantly better than leg wrapping did in our study.

Page 49: Haemodynamics during Vaginal and Caesarean Delivery in

45

Effect of Phenylephrine and Leg Wrapping on Overall Haemodynamics In all treatment groups, the decrease in SAP was preceded by a sudden and profound

decrease in SVR, and a compensatory increase in HR, SV, and CO. Study I thus confirms

that spinal anaesthesia causes prompt arterial vasodilation with a marked decrease in

afterload, in keeping with the past years’ fundamental change in pathophysiological

understanding of spinal hypotension.19,32 Notwithstanding the consistently limited success of

preventive strategies stabilising venous circulation,45,125 and the fact that impaired venous

return with a significant reduction in CO is no longer considered the primary cause of spinal

hypotension during CD, lower limb compression has been continued in a number of

institutions, and has been recommended by some authors, even very recently, as the primary

prophylactic method against spinal hypotension.44 The observation that phenylephrine, but

not leg wrapping, counteracted the decrease in SVR in Study I clearly demonstrates that the

alpha1-agonist phenylephrine prevents spinal hypotension in a more physiological manner

than lower limb compression. A survey on current clinical practice in Europe revealed that, in

2012, only 20% of clinicians used prophylactic vasopressor against spinal hypotension during

CD.26 Modern haemodynamic management of spinal hypotension is probably implemented

more widely in clinical practice today, but we are not aware of any up-to-date survey. Our

findings are another piece of evidence in support of phenylephrine as first-line prophylaxis.

The paradigm shift that not venous but arteriolar vasodilation is the main reason for spinal

hypotension has more or less eliminated mention of venodilation from the pathophysiological

debate during recent years. It is therefore an interesting observation that the initial increase in

SV was more pronounced in the leg wrapping group than in the control group. This may imply

that spinal anaesthesia causes minor venodilation, which to a lesser extent also contributes to

hypotension. Continuously higher SV in the leg wrapping group compared with the control

group, in spite of similarly low afterload in both groups, indicates that venous recruitment by

leg wrapping may help to stabilise preload.

In spite of higher SVR in the phenylephrine group compared with the leg wrapping group, SV

was similar in both groups. This observation may indicate that phenylephrine generates a

higher preload than leg wrapping does. The finding that SV remained above baseline when

SVR was restored to baseline indicates that the preload increase in phenylephrine patients

persists.126 Our results therefore imply that phenylephrine restores blood pressure not only by

its action on the arterial but also on the venous side of the vascular system. The physiological

mechanism for this may be alpha-agonist-mediated splanchnic venous recruitment by

phenylephrine. This would be in keeping with the literature describing that constriction of

preportal veins by low phenylephrine doses shifts blood centrally.28,29,127-129

Page 50: Haemodynamics during Vaginal and Caesarean Delivery in

46

The rapid and prominent increase in CO was caused by increases in SV and HR, following

the sudden decrease in afterload in all three groups. The subsequent gradual reduction in HR

was most pronounced in the phenylephrine group. Lower continuous HR and CO in the

phenylephrine than in the leg wrapping group indicate that cardiac effort was less in the

former. These findings underline that phenylephrine, by counteracting arterial vasodilation

and baroreceptor-mediated tachycardia, and simultaneously maintaining preload, has a more

favourable effect on the overall haemodynamic condition than leg wrapping does. Several

recent publications suggest that HR may serve as a clinical surrogate marker for CO, and

may help to guide titration of phenylephrine in healthy parturients during spinal anaesthesia

for caesarean delivery.27,32,35

One frequently raised concern about phenylephrine is that it may cause reflex bradycardia,

and a concomitant decrease in CO, particularly when higher doses are used. A study

comparing prophylactic infusion of noradrenaline to phenylephrine with the aim of preventing

bradycardia and a decrease in CO, found a lower incidence of bradycardia (defined as

HR<60 bpm) and a slightly higher mean HR in the noradrenaline group.130 However, with

relatively higher doses needed to keep blood pressure equally stable, lower SVR, and a

lasting increase in CO by almost 20% above baseline after the first five minutes,

noradrenaline did not have a superior overall haemodynamic effect compared to

phenylephrine. Bradycardia and an associated decrease in CO are often the result of

overtreated blood pressure, hence a β-effect as from noradrenaline is usually unnecessary in

healthy parturients.77 With our phenylephrine regimen, CO was restored to slightly below

baseline. The incidence of bradycardia was minimal, and, in view of mildly tachycardic

baseline values, the gradual decrease in heart rate to 10 beats/minute below baseline was

probably of physiological benefit.

According to the classic baroreceptor reflex concept, hypotension is the direct cause of reflex

tachycardia after spinal induction.131 In our study, the HR increase in all three groups

occurred prior to hypotension. We therefore think that other cardiovascular reflexes might

play a role, or that the initial increase in HR might be a direct response to reduced SVR, i.e.

that the reflex receptor fibres are sensitive to changes not only in pressure, but also in

resistance.

The principal goal during spinal anaesthesia for CD is ensuring maternal and foetal safety

and wellbeing by maintaining haemodynamics close to resting physiological baselines.35

Permissive hypotension around 10% below baseline has been suggested as a specific goal in

order to warrant sufficient stabilisation of blood pressure whilst preventing side effects from

phenylephrine, i.e. bradycardia and a significant decrease in CO.19 With a mean decrease in

SAP of 8% from baseline, no reactive hypertension, a minimal incidence of bradycardia, and

a very slight reduction in CO, our regimen came close to this goal. As stated above, however,

we think that a higher initial bolus added to low- or variable-rate phenylephrine infusion might

achieve an even better balance.

Page 51: Haemodynamics during Vaginal and Caesarean Delivery in

47

Neonatal Outcome All umbilical cord blood gases and Apgar values were within normal range, and pH, BE, and

Apgar were similar in all groups, indicating that the maternal haemodynamic condition and

rescue-pressor doses were well tolerated by newborns in all three groups. Lower umbilical

artery and vein lactate in the phenylephrine group might suggest slightly less metabolic stress

than in the leg wrapping and control groups.

In view of the excellent neonatal outcomes even in the placebo group, some might question

the importance of maternal haemodynamic prophylaxis. First of all, continuous monitoring and

a strict treatment protocol in case of hypotension contributed to prevention of prolonged

severe hypotension, and of possible neonatal impairment, in our study. Second, while short-

lived hypotensive episodes generally do not harm healthy babies in low-risk deliveries, they

may exacerbate the condition of compromised infants who, due to prenatal impairment or

complicated delivery, already are at risk of acidosis and intrapartum hypoxia.22,42,132 Hence,

optimising maternal haemodynamics during CD, and avoiding any other contributions to

potentially negative outcomes, are the safest working principles in regard to neonatal

condition.42,132

Due to a good ‘safety margin’ between uterine blood flow and foetal oxygen demand under

normal physiological conditions, healthy foetuses usually tolerate some reduction in blood

pressure or CO well.35 Previous studies have shown good clinical neonatal outcomes after

high doses of ephedrine leading to maternal tachycardia and umbilical acidosis,42,60,69,70 and

after high-dose phenylephrine infusions leading to maternal bradycardia and

hypertension.68,74,75 These findings underline that maternal circulation, rather than umbilical

pH or Apgar scores, should be the primary focus of vasopressor choice and general

anaesthetic management.27,57

Page 52: Haemodynamics during Vaginal and Caesarean Delivery in

48

7.2 Discussion of Study II Study II demonstrated a profound impact of spontaneous labour and vaginal delivery on

maternal haemodynamics in healthy parturients. This is the first study monitoring maternal

haemodynamic changes continuously during all labour stages in a cohort of healthy women.

The data show that contractions induce considerable haemodynamic changes starting early

in active labour, and question whether epidural analgesia has a major effect on these

changes.

Haemodynamic Baseline Values in Stages 1 and 2 Similar baseline values across stages for all haemodynamic variables in Study II imply that

progression of labour has no major effect on haemodynamics during rest between

contractions. Previous studies have provided controversial results on whether progressing

labour leads to a cumulative increase in resting CO9,12,14,18 or not.10,11,15 This discrepancy

might be due to the use of non-continuous or unreliable monitoring techniques,18 or perhaps

to confounders such as intravenous administration of different fluids or medicines during the

course of labour. However, a larger sample size than ours would be needed to detect minor

differences in baselines between labour stages.

Haemodynamics during Contractions Stage 1 contractions generated considerable changes in all haemodynamic variables, and

these changes increased slightly between early and late stage 1. During stage 2 contractions

and delivery, haemodynamic changes were more uniform and more substantial than during

stage 1, with prominent increases in SAP, HR, and SVR, and profound decreases in SV and

CO in all parturients. A variety of mechanical, neurophysiological, and endocrine factors may

affect haemodynamic changes during labour.11 Their investigation was beyond the scope of

our project, and previous evidence is sparse, hence the pathophysiological interactions

behind our findings remain speculative.

During stage 1 contractions, increases in SAP in our parturients were greater than the

increases in blood pressure11,12,14,15 reported by most authors in the past. During stage 2,

increases in SAP in our parturients were more prominent than during stage 1, and of similar

extent as in three previous studies reporting blood pressure during stage 2.11,12,14 Blood

pressure responses during labour may depend on pain and stress, but possibly also on

neurohumoral control independent of pain.11,133,134

The increases in HR during stage 1 contractions in Study II were greater than previously

reported increases in HR.10,11,17,18 One former research group found decreases in HR during

contractions, which they ascribed to the baroreceptor reflex.12,13 We did not observe a primary

decrease in HR during contractions in Study II, but the initial increase was often followed by a

short decrease before values returned to baseline. Tachycardia during contractions was more

prominent in stage 2 than in stage 1, and also more prominent than in two previous studies

describing HR during stage 2.11,14

Page 53: Haemodynamics during Vaginal and Caesarean Delivery in

49

While stage 1 contractions caused either increases or decreases in SVR, stage 2

contractions led to considerable increases in SVR in all parturients. In view of blood pressure

increases11,12,14,15 and adrenergic activation133,134 during labour, the decreases in SVR during

contractions in some of our parturients, in the absence of epidural analgesia, were rather

unexpected. Most previous studies did not explicitly report on SVR, but one author group also

found decreases in SVR during stage 1 contractions.15 There is an increasing body of

evidence on reflex systems and local biochemical agents controlling SVR under stress and

exercise.135 The pathophysiology of SVR regulation during labour is not elucidated yet, and

might be an interesting subject for future research. For instance, progressively increasing

levels of intrinsic norepinephrine during labour, as well as maximal catecholamine levels at

the time of delivery, and their rapid decline directly after delivery have been shown,133 but

neither the exact timing pattern of catecholamine secretion during progressing labour, nor the

possible effects on haemodynamics have been investigated so far. Other studies found

progressive increases in oxytocin and prostaglandin,136 and pulsatile secretion of intrinsic

oxytocin at several-minute intervals during labour.136,137 Since bolus administration of

synthetic oxytocin reduces SVR,138 it might be interesting to study whether intrinsic oxytocin

pulses significantly affect maternal haemodynamics. In general, we suppose that

cardiovascular reflexes131,139-142 contributed to the spectre of observed haemodynamic

changes in our parturients. Beyond that, it might be instructive to examine potential

correlations between haemodynamic changes and uterine pressure.

Study II showed that SV may either increase or decrease during stage 1 contractions, and

thus confirms both the rises in SV observed by most authors,12-15,17 and the declines in SV

observed by a few others.10,11 Stage 2 contractions, by contrast, generated decreases in SV

in all our parturients, and these were more profound than the decreases during stage 1. To

our knowledge, no previous study has achieved reliable SV measurements during stage 2

contractions before. Decreases in SV might be caused by concomitant increases in afterload,

or, since there were cases with parallel decreases in SV and afterload during stage 1 in Study

II, by reduced filling time due to tachycardia, or by decreased venous return due to caval

compression.90 Increased intrathoracic pressure during bearing-down effort reduces venous

return,9 and did probably contribute to the significant extent of decreases in SV during stage

2. Increases in SV have mainly been ascribed to blood redistribution from the contracting

uterus,9,10,14,15,18,143 but this hypothesis remains to be confirmed, as direct evidence for the

volume and clinical effect of autotransfusion seems to be absent. Alternatively,

catecholamine-mediated cardiac stimulation,11,18,143 splanchnic recruitment, or other

cardiovascular mechanisms127,128 might contribute to increases in SV.

The mean increase in CO of around 50% during stage 1 contractions in Study II was larger

than the increases of 20 % to 30% observed in most earlier studies.9-15,17 One study revealed

an 84% increase in CO, but the authors doubted whether their measurements by bio-

impedance were reliable.18 Decreases in CO during stage 1, as detected in some of our

Page 54: Haemodynamics during Vaginal and Caesarean Delivery in

50

parturients, have only been observed by one other research group.11 The considerable

decreases in CO during stage 2 in our parturients confirm findings described in a recent case

report.49 The increases in CO in Study II were the result of either concomitantly increased HR

and SV, or of increased HR and decreased SV. The decreases in CO occurred either during

the entire contraction or only during the peak of contraction, as a result of increasing HR

being outweighed by decreasing SV.

Except from the recent single case with similar haemodynamic changes as parturients in

Study II,49 reliable CO measurements during bearing down have so far not been reported in

any other study.18,49 Almost all previous studies were based on dye dilution techniques,10-16

the reliability of which depends on stable CO during an ongoing measurement.18 Several

seconds pass from injection of the dye agent to appearance of the dilution curve,15 and the

recording takes around half a minute.17 Beat-by-beat monitoring with LiDCOplus in Study II

illustrates that, during ongoing contractions, important haemodynamic changes may occur

within only a few seconds. The reliability of bio-impedance18 and Echo Doppler17

measurements, too, is restricted during brisk haemodynamic fluctuations. Inconsistent

findings on CO and SV in the early studies9-18 have mainly been assigned to non-continuous,

unreliable monitoring techniques,11,18 as well as to differences in posture, intravenous fluids

and administered medicines.14,18 However, continuous invasive monitoring in Study II

revealed some haemodynamic inter-parturient variability, which we assume may be an

additional reason for conflicting previous evidence.

The LiDCOplus technique enabled continuous haemodynamic measurements during the

entire course of labour, including delivery. In some parturients, however, LiDCO traces

showed extreme haemodynamic values, or brief disruptions at the time of peak effort during

several stage 2 and delivery contractions, even though the arterial cannulas were patent and

the parturients’ upper limbs relaxed. Since this phenomenon was observed in a few

individual stage 2 contractions when no voluntary valsalva effort was performed, we assume

that intense vasoconstriction may have played a role in these cases.

Study II provides some new evidence, but numerous questions remain concerning the

profound haemodynamic changes and the observed inter-parturient variability, and more

research is needed to deepen understanding of haemodynamics during contractions. Future

studies should investigate larger samples, and use synchronised continuous haemodynamic

and tocodynamic monitoring. Studies with sophisticated design, including advanced blood

sampling protocols, would be needed in order to shed more light on whether, and to what

extent, endocrine changes affect haemodynamics at different moments during progressing

labour.

Page 55: Haemodynamics during Vaginal and Caesarean Delivery in

51

Haemodynamics during Labour with Epidural Analgesia Marginal linear model analyses of haemodynamic data by labour stage revealed small non-

significant effect estimates for epidural analgesia. Furthermore, haemodynamic analyses

yielded similar results when including and excluding epidural analgesia as independent factor.

Epidural analgesia was titrated to reduce pain while maintaining motor function in our study.

Effectiveness of epidural analgesia was verified by reduction of both pain scores and

sensitivity to cold. However, since neither of them was included in the marginal model

analyses, limited longitudinal effect must be considered as a possible reason for the absent

influence on haemodynamics. Two previous studies using relatively higher epidural doses

than those in Study II, reported mild14 or no12 effect of caudal analgesia on haemodynamic

changes during contractions, but the reliability of their results might be limited, due to

intermittent and possibly unreliable haemodynamic monitoring techniques. Considering that

estimates for the effect of epidural analgesia on baseline SVR in Study II were close to the

significance level, a decreasing effect of epidural analgesia on baseline SVR might have been

detected using similar epidural doses in a larger sample. This would be in line with the clinical

understanding that sympathetic blockade by epidural analgesia may lead to some degree of

vasodilation.144 Epidural analgesia may also transiently reduce maternal blood pressure, but

most studies have assessed the overall incidence of hypotension (5% to 30%) as a side

outcome, without reporting blood pressure during the course of labour.144 Both the intended

analgesic and the adverse effects of epidural analgesia are subject to dosage. Local

anaesthetic regimens providing near-complete sensory block may impede mobility as well as

bearing-down ability, and induce considerable hypotension.144

Our study was not suited to quantifying the influence of epidural analgesia on pain and

haemodynamics, but in light of the above-described findings, we question whether epidural

analgesia dosed to reduce pain but maintain motor function has a major effect on

haemodynamic changes during contractions. Anxiety, stress, and pain have been the main

postulated causes for increasing HR, SVR, and SAP during contractions,134 but the actual

effect of these factors or of analgesic treatment on haemodynamic changes has never been

determined. Previously observed similar norepinephrine levels in parturients with and without

epidural analgesia,133 increases in SAP prior to subjectively perceived contractions,11 and

significant haemodynamic changes in a parturient with epidural analgesia and little pain49

indicate that other factors than pain might contribute to increases in HR, afterload, and blood

pressure during contractions.

Comparison of haemodynamics between parturients with and without epidural analgesia in

large randomised, controlled trials would be interesting and valuable, but challenging practical

aspects, and high drop-out rates due to cross-over from control to epidural analgesia should

be expected and taken into account in the study planning.

Page 56: Haemodynamics during Vaginal and Caesarean Delivery in

52

Haemodynamics Postpartum Similar baseline values as in stages 1 and 2, and the absence of a significant increase in SV

and CO, directly postpartum are in contrast to some of the early studies which reported

an important increase in resting CO during the first few minutes after delivery.12,14-16 Our

observations therefore question the common belief48,51,52,143,145,146 in a major increase in

venous return after delivery, caused by autotransfusion from the contracted uterus, and

corroborate doubts about this theory expressed by other authors.10,11,15,147 The conjecture that

an intravenous oxytocin bolus might have led to the increase in CO in the respective ancient

studies147 received support from a recent publication reporting increases in SV after a

postpartum bolus of either oxytocin or carbetocin, but not after placebo, during CD.94 Postural

changes and the relief of caval compression have been postulated as alternative causes of a

postpartum increase in CO.15,18 The fact that all of the patients in the carbetocin study94 were

in the supine position with left lateral tilt during the complete monitoring period rather supports

the oxytocin hypothesis. Routines of oxytocin administration are not described in all of the

historic studies,9,12,18 but an oxytocin bolus immediately after delivery is reported in some of

the studies with a postpartum increase in CO.14,16 In our study, oxytocin was administered

intramuscularly a few minutes after delivery, and was therefore unlikely to exert any

haemodynamic effect within the monitoring period.

Labour has a profound impact on maternal circulation, and may last several hours, but early

postpartum haemodynamic values and good general condition suggest that the circulatory

impact of labour was well tolerated by parturients in Study II. Late postpartum and longterm

cardiovascular outcomes were not assessed. Clinical Value of Haemodynamic Monitoring during Labour Knowledge about typical haemodynamic changes during labour may be a valuable basis for

clinical assessment and management of parturients, particularly in case of unexpected

adverse events. Since we examined healthy women, we cannot draw any conclusions on

behalf of compromised parturients. Evidence on haemodynamics in healthy parturients might,

however, have a potential indirect value for clinical considerations and future research in

pathological conditions. Acute cardiac events, and diagnosed or undiagnosed pre-existing

cardiac disease, are among the leading causes of maternal mortality.5 While healthy

parturients tolerate labour generally well, haemodynamic implications of VD in parturients with

cardiac compromise are controversial.1,52,146,148 In consideration of obstetric benefits and

avoidance of surgical complications, current guidelines recommend VD for the majority of

parturients at cardiac risk.1,51,52,149 The potentially deleterious effects of high myocardial

workload on the compromised heart are well known,1,51,146,150,151 but most authors state that

limiting valsalva effort and duration of the second stage by assisted delivery, and limiting pain

by epidural analgesia, are efficient means to reduce maternal haemodynamic stress, and thus

the risk of adverse outcome.1,51,52,149 Reliable evidence is sparse,148 and to our knowledge, no

study has quantified the haemodynamic effect of epidural analgesia, or of normal and limited

Page 57: Haemodynamics during Vaginal and Caesarean Delivery in

53

pushing during second-stage contractions in healthy or compromised parturients. Neither has

our project, but Study II shows that haemodynamic changes may be profound already in the

first labour stage, and questions whether moderately dosed epidural analgesia significantly

reduces maternal cardiovascular stress during contractions. We think that the observed

haemodynamic fluctuations might have the potential to aggravate the condition of parturients

at cardiac risk, and point up the need for future research in this population.

Neonatal Outcome A high number of missing values limits the interpretability of umbilical cord blood gases in

Study II, but the Apgar values indicate good clinical neonatal outcome. 7.3 Comment across Studies I and II This Ph.D. project investigated maternal haemodynamics during spinal anaesthesia for

caesarean delivery in Study I, and during vaginal delivery in Study II, but the project was not

suited for assessment of haemodynamics across the two studies.

Haemodynamics during VD and CD obviously differ in some general points. The exact

pathophysiological mechanisms behind the haemodynamic changes during labour are

complex, and not entirely understood, but intrinsic adrenergic stimulation likely plays a

role.133,134 Conversely, iatrogenic inhibition of sympathetic pathways is responsible for the

haemodynamic changes during spinal anaesthesia for CD.22 While hypotension therefore is a

major concern during CD,22 contractions during VD are usually accompanied by intermittent

hypertension.11,12,14,15

The limited extent and duration of haemodynamic changes during CD in the phenylephrine

group in Study I may seem to constitute less cardiovascular stress than the profound

haemodynamic fluctuations during the protracted course of labour in Study II, but our project

design does not permit any valid conclusions on this matter, and haemodynamic outcomes of

CD and VD have never been compared by reliable advanced monitoring techniques in any

previous study. Both haemodynamic management during CD and the haemodynamic impact

of labour were seemingly well tolerated by the healthy participants and neonates of Studies I

and II, respectively. Implications of both VD and CD on circulation in compromised parturients

are controversial.1,52,146,148 Several contemporary authors have pointed at the importance of

solid haemodynamic understanding146 and the necessity of high-quality prospective studies

providing evidence upon which to base future clinical practice in both healthy and

compromised parturients.49,148,149,151 We think that the profound haemodynamic impact of first-

and second-stage contractions in Study II underline the need for future research into short-

and long-term cardiovascular outcomes of vaginal delivery compared to haemodynamically

well-managed caesarean delivery, particularly in parturients at cardiac risk.

Page 58: Haemodynamics during Vaginal and Caesarean Delivery in

54

8 CONCLUSIONS

1. Low-dose phenylephrine infusion is superior to leg wrapping and to no intervention for

preventing spinal hypotension during CD. Leg wrapping has a limited preventive effect on

spinal hypotension compared with no intervention.

2. Study I confirms that spinal anaesthesia induces a rapid decrease in SVR, and a

compensatory increase in HR, SV, and CO. Study I indicates that there is also modest

venodilation after induction of spinal anaesthesia. The reduction in afterload is

counteracted by phenylephrine but not by leg wrapping. Both phenylephrine and leg

wrapping contribute to the maintenance of preload. In summary, phenylephrine has a

more favourable effect than leg wrapping on the overall haemodynamic condition.

3. A phenylephrine regimen consisting of a small initial bolus (0.25 µg/kg) followed by low-

dose infusion (0.25 µg/kg/min) stabilises SAP, and restores HR and CO to levels slightly

below baseline, without clinically significant adverse effects. The initial decrease in SAP is

attenuated but not completely prevented by this regimen, hence the initial phenylephrine

bolus should probably be increased.

4. Both prophylactic low-dose phenylephrine infusion and leg wrapping are well tolerated by

healthy newborns of healthy mothers.

5. During labour, stage 1 contractions cause prominent increases in SAP and HR, and

either increases or decreases in SVR and SV. Cardiac output may either increase or

decrease, depending on the relative extent of changes in SV and HR. During stage 2

contractions, the changes are more uniform, with pronounced increases in SAP, HR, and

SVR, and profound decreases in SV and CO in all parturients.

6. Haemodynamic changes during contractions are profound, both in early and late active

labour. The extent of maternal haemodynamic changes is most substantial during

bearing-down effort in stage 2. The haemodynamic impact of labour is probably stronger

than formerly shown.

7. Progress of labour itself has no major influence on haemodynamic baselines. Stable SV

and CO in the immediate postpartum period query the common belief that delivery itself

leads to a significant myometrial autotransfusion.

8. Our findings question whether epidural analgesia significantly minimises the effect of

contractions on maternal circulation.

Page 59: Haemodynamics during Vaginal and Caesarean Delivery in

55

9 CLINICAL IMPLICATIONS

Based on the findings in Study I, the combination of prophylactic phenylephrine infusion and

cohydration should remain the method of choice for prevention of spinal hypotension during

CD. Phenylephrine is a more efficient and a more physiological approach to prevention of

spinal hypotension than leg wrapping, hence institutions still using leg wrapping as first-

choice prophylaxis should change their protocols to using phenylephrine. Leg wrapping may

serve as an alternative prophylactic method, in settings where phenylephrine is not available.

Adding an initial bolus to low-dose phenylephrine infusion can be recommended in order to

improve haemodynamic stabilisation, while keeping the incidence of adverse effects low. A

higher bolus dose than in our study, probably between 40 μg and 60 μg, might help to further

optimise the prevention of the initial decrease in blood pressure. The negative effect of

phenylephrine on HR and CO is of physiological benefit when used in low doses, as it

reduces cardiac effort. However, it is important to keep in mind that high doses of

phenylephrine may induce hypertension, bradycardia, and an unreasonable degree of cardiac

output depression, and should therefore be avoided.27,57

In general, Study I substantiates that preventive and therapeutic means against spinal

hypotension should primarily focus on stabilising afterload, and on keeping heart rate and

cardiac output close to baseline, hence limiting maternal cardiac effort.27,57

The observation that transient moderate maternal haemodynamic imbalance is well tolerated

by healthy newborns confirms that maternal circulation, rather than neonatal outcome, should

be the primary focus of prophylactic strategies against spinal hypotension.27

Study II, indicating that haemodynamic stress during stage 1 may be more substantial than

previously assumed, and being the first study to evidence the considerable CO changes

during expulsive effort in stage 2, underlines the importance of realistic appraisal of every

parturient’s tolerance for profound haemodynamic fluctuations, at an early point during labour.

A cardiovascular burden as observed in Study II is usually well tolerated by healthy

parturients, but might have the potential to worsen the condition of women with cardiac

disease, and to promote circulatory complications in predisposed parturients. A parturient’s

resilience to significant intermittent hypertension and CO depression during bearing-down

effort should receive particular consideration in clinical decisions on mode of delivery, or on

management of expulsive effort, for instance. The threshold for continuous minimally invasive

monitoring in parturients at risk should probably be low.

Until future studies provide valid evidence, clinicians should arguably not rely on epidural

analgesia to eliminate the haemodynamic impact of contractions.

Based on our personal experience, the LiDCOplus may prove useful for future

haemodynamic research during labour.

Page 60: Haemodynamics during Vaginal and Caesarean Delivery in

56

10 FUTURE RESEARCH

The pathophysiology and management of spinal hypotension during CD in healthy parturients

are well elucidated by now. A few questions remain, concerning:

• which mechanism leads to the rare presentation of hypotension and accompanying

bradycardia in direct response to spinal anaesthesia;3,35

• the exact dose-related effects of phenylephrine on venous return35 and uterine blood

flow; and

• the effect of blood pressure and CO on uterine blood flow.81

Future haemodynamic research in the context of CD should concentrate on circulation in

parturients with preeclampsia, cardiac disease,27,31 or other pathologies. Of interest are i.a.:

• the haemodynamic effects of spinal anaesthesia in pre-eclampsia;

• optimal vasopressor and general clinical management during CD in pre-eclampsia,

cardiac disease,27 or vasopressin depletion;152

• the effects of oxytocin receptor agonists in pre-eclampsia;98 and

• the effects of phenylephrine on uterine blood flow in placental insufficiency.36,81

There are many unanswered questions concerning the complex interactions of mechanical,

neurophysiological, endocrine, and external factors that may influence haemodynamic

changes during labour. Large studies with sophisticated design would be needed in order to

draw definite conclusions. Of interest are the detailed haemodynamic effects of i.a.:

• the uterine tone;

• positioning and volume state;

• epidural analgesia, remifentanil analgesia, and labour augmentation; and

• neuro-endocrine factors (intrinsic oxytocin, catecholamines, and cortisol, for example).

Future research should focus on parturients with pre-eclampsia or cardiac disease.

Randomised, controlled trials may be difficult both from a practical and ethical perspective,

hence observational studies are more realistic. To obtain data that are as complete and valid

as possible, continuous haemodynamic monitoring should be used.53,57,153

Page 61: Haemodynamics during Vaginal and Caesarean Delivery in

57

Page 62: Haemodynamics during Vaginal and Caesarean Delivery in

58

11 REFERENCES

1 Dob DP, Yentis SM. Practical management of the parturient with congenital heart disease. Int J Obstet

Anesth 2006;15(2):137–44. Doi: 10.1016/j.ijoa.2005.07.005.

2 Cyna AM, Andrew M, Emmett RS, Middleton P, Simmons SW. Techniques for preventing hypotension

during spinal anaesthesia for caesarean section. Cochrane Database Syst Rev 2006;(4):CD002251. Doi:

10.1002/14651858.CD002251.pub2.

3 Dyer RA. Obstetric anaesthesia: Is there anything new under the sun? South Afr J Anaesth Analg

2013;19(1):29–32.

4 Hess PE. What’s New in Obstetric Anesthesia. Anesth Analg 2017;124(3):863–71. Doi:

10.1213/ANE.0000000000001681.

5 Cantwell R, Clutton-Brock T, Cooper G, et al. Saving Mothers' Lives: Reviewing maternal deaths to make

motherhood safer: 2006-2008. The Eighth Report of the Confidential Enquiries into Maternal Deaths in the

United Kingdom. Br J Obstet Gynaecol 2011;118 Suppl 1:1–203. Doi: 10.1111/j.1471-0528.2010.02847.x.

6 Freedman RL, Lucas DN. MBRRACE-UK: saving lives, improving mothers' care - implications for

anaesthetists. Int J Obstet Anesth 2015;24(2):161–73. Doi: 10.1016/j.ijoa.2015.03.004.

7 Gogarten W. Spinal anaesthesia for obstetrics. Best Pract Res Clin Anaesthesiol 2003;17(3):377–92. Doi:

10.1016/S1521-6896(02)00116-7.

8 Glosten B. Anesthesia for obstetrics. : Miller RD, editor. Anesthesia, vol. 2. 5 ed. Philadelphia: Churchill

Livingstone; 2000. pp. 2024–68.

9 Hendricks CH, Quilligan EJ. Cardiac Output during Labor. Am J Obstet Gynecol 1956;71(5):953–72.

10 Adams JQ, Alexander AM. Alterations in cardiovascular physiology during labor. Obstet Gynecol

1958;12(5):542–9.

11 Winner W, Romney SL. Cardiovascular responses to labour and delivery. Am J Obstet Gynecol 1966:1–11.

12 Hansen JM, Ueland K. The influence of caudal analgesia on cardiovascular dynamics during normal labor

and delivery. Acta Anaesthesiol Scand Suppl 1966;23:449–52.

13 Ueland K, Hansen JM. Maternal cardiovascular dynamics. II. Posture and uterine contractions. Am J Obstet

Gynecol 1969;103(1):1–7.

14 Ueland K, Hansen JM. Maternal cardiovascular dynamics. III. Labor and delivery under local and caudal

analgesia. Am J Obstet Gynecol 1969;103(1):8–18.

15 Lees MM, Scott DB, Kerr MG. Haemodynamic changes associated with labour. J Obstet Gynaecol Br

Commonw 1970;77(1):29–36.

16 Niswonger JW, Langmade CF. Cardiovascular changes in vaginal deliveries and cesarean sections. Am J

Obstet Gynecol 1970;107(3):337–44.

17 Robson SC, Dunlop W, Boys RJ, Hunter S. Cardiac output during labour. Br Med J (Clin Res Ed)

1987;295(6607):1169–72.

18 Filippatos GS, Baltopoulos G, Lazaris D, et al. Cardiac output monitoring during vaginal delivery. J Obstet

Gynaecol 1997;17(3):270–2. Doi: 10.1080/01443619750113249.

19 Langesæter E, Rosseland LA, Stubhaug A. Continuous invasive blood pressure and cardiac output

monitoring during cesarean delivery: a randomized, double-blind comparison of low-dose versus high-dose

spinal anesthesia with intravenous phenylephrine or placebo infusion. Anesthesiology 2008;109(5):856–63.

Doi: 10.1097/ALN.0b013e31818a401f.

20 Reidy J, Douglas J. Vasopressors in obstetrics. Anesthesiol Clin 2008;26(1):75–88–vi–vii. Doi:

10.1016/j.anclin.2007.11.005.

21 Smiley RM. Burden of proof. Anesthesiology 2009;111(3):470–2. Doi: 10.1097/ALN.0b013e3181b16466.

22 Dyer RA, Arcache MJ, Langesæter E. The Aetiology and Management of Hypotension during Spinal

Anaesthesia for Caesarean Delivery. : Clark V, Van de Velde M, Fernando R, editors. Oxford Textbook of

Obstetric Anaesthesia. 1st ed. Oxford, UK: Oxford University Press; 2016. pp. 1–39.

23 Macarthur A, Riley ET. Obstetric anesthesia controversies: vasopressor choice for postspinal hypotension

during cesarean delivery. Int Anesthesiol Clin 2007;45(1):115–32. Doi: 10.1097/AIA.0b013e31802b8d53.

Page 63: Haemodynamics during Vaginal and Caesarean Delivery in

59

24 Ngan Kee WD, Khaw KS. Vasopressors in obstetrics: what should we be using? Curr Opin Anaesthesiol

2006;19(3):238–43. Doi: 10.1097/01.aco.0000192816.22989.ba.

25 Lirk P, Haller I, Wong CA. Management of spinal anaesthesia-induced hypotension for caesarean delivery.

Europ J Anaesthesiol 2012;29(9):452–3. Doi: 10.1097/EJA.0b013e328352ab10.

26 Staikou C, Paraskeva A, Karmaniolou I, Mani A, Chondrogiannis K. Current practice in obstetric anesthesia:

a 2012 European survey. Minerva Anestesiol 2014;80(3):347–54.

27 Langesæter E, Dyer RA. Maternal haemodynamic changes during spinal anaesthesia for caesarean

section. Curr Opin Anaesthesiol 2011;24(3):242–8. Doi: 10.1097/ACO.0b013e32834588c5.

28 Thiele RH, Nemergut EC, Lynch C III. The Physiologic Implications of Isolated Alpha1 Adrenergic

Stimulation. Anesth Analg 2011;113(2):284–96. Doi: 10.1213/ANE.0b013e3182124c0e.

29 Thiele RH, Nemergut EC, Lynch C III. The Clinical Implications of Isolated Alpha1 Adrenergic Stimulation.

Anesth Analg 2011;113(2):297–304. Doi: 10.1213/ANE.0b013e3182120ca5.

30 Ngan Kee WD. Phenylephrine Infusions for Maintaining Blood Pressure During Spinal Anesthesia for

Cesarean Delivery. Anesth Analg 2014;118(3):496–8. Doi: 10.1213/ANE.0000000000000111.

31 Dyer RA, Piercy JL, Reed AR, et al. Hemodynamic changes associated with spinal anesthesia for cesarean

delivery in severe preeclampsia. Anesthesiology 2008;108(5):802–11. Doi:

10.1097/01.anes.0000311153.84687.c7.

32 Dyer RA, Reed AR, van Dyk D, et al. Hemodynamic effects of ephedrine, phenylephrine, and the

coadministration of phenylephrine with oxytocin during spinal anesthesia for elective cesarean delivery.

Anesthesiology 2009;111(4):753–65. Doi: 10.1097/ALN.0b013e3181b437e0.

33 Stewart A, Fernando R, McDonald S, et al. The Dose-Dependent Effects of Phenylephrine for Elective

Cesarean Delivery Under Spinal Anesthesia. Anesth Analg 2010;111(5):1230–7. Doi:

10.1213/ANE.0b013e3181f2eae1.

34 Doherty A, Ohashi Y, Downey K, Carvalho JCA. Phenylephrine infusion versus bolus regimens during

cesarean delivery under spinal anesthesia: a double-blind randomized clinical trial to assess hemodynamic

changes. Anesth Analg 2012;115(6):1343–50. Doi: 10.1213/ANE.0b013e31826ac3db.

35 Dyer RA, Reed AR. Spinal Hypotension During Elective Cesarean Delivery. Anesth Analg

2010;111(5):1093–5. Doi: 10.1213/ANE.0b013e3181ea5f77.

36 Lee AJ, Smiley RM. Phenylephrine infusions during cesarean section under spinal anesthesia. Int

Anesthesiol Clin 2014;52(2):29–47. Doi: 10.1097/AIA.0000000000000010.

37 Bhagwanjee S, Rocke DA, Rout CC, Koovarjee RV, Brijball R. Prevention of hypotension following spinal

anaesthesia for elective caesarean section by wrapping of the legs. Br J Anaesth 1990;65(6):819–22.

38 Rout CC, Rocke DA, Gouws E. Leg elevation and wrapping in the prevention of hypotension following spinal

anaesthesia for elective caesarean section. Anaesthesia 1993;48(4):304–8.

39 van Bogaert LJ. Prevention of post-spinal hypotension at elective cesarean section by wrapping of the lower

limbs. Int J Gynaecol Obstet 1998;61(3):233–8.

40 Sun HL, Ling QD, Sun WZ, et al. Lower limb wrapping prevents hypotension, but not hypothermia or

shivering, after the introduction of epidural anesthesia for cesarean delivery. Anesth Analg 2004;99(1):241–

4.

41 Morgan PJ, Halpern SH, Tarshis J. The effects of an increase of central blood volume before spinal

anesthesia for cesarean delivery: a qualitative systematic review. Anesth Analg 2001;92(4):997–1005.

42 Ngan Kee WD, Lee A. Multivariate analysis of factors associated with umbilical arterial pH and standard

base excess after Caesarean section under spinal anaesthesia. Anaesthesia 2003;58(2):125–30.

43 Bjørnestad E, Iversen OE, Ræder J. Wrapping of the legs versus phenylephrine for reducing hypotension in

parturients having epidural anaesthesia for caesarean section: a prospective, randomized and double-blind

study. Europ J Anaesthesiol 2009;26(10):842–6. Doi: 10.1097/EJA.0b013e328329b028.

44 Mohamed AI, Elazhary RAH, Abdelhady RM, Sadek El B, Said KM. Utilization of lower leg compression

technique for reducing spinal induced hypotension, and related risks for mothers and neonates during

cesarean delivery. Jnep 2016;6(7). Doi: 10.5430/jnep.v6n7p11.

Page 64: Haemodynamics during Vaginal and Caesarean Delivery in

60

45 Sharwood-Smith G, Drummond GB. Hypotension in obstetric spinal anaesthesia: a lesson from pre-

eclampsia. Br J Anaesth 2009;102(3):291–4. Doi: 10.1093/bja/aep003.

46 van Oppen AC, van der Tweel I, Alsbach GP, Heethaar RM, Bruinse HW. A longitudinal study of maternal

hemodynamics during normal pregnancy. Obstet Gynecol 1996;88(1):40–6. Doi: 10.1016/0029-

7844(96)00069-5.

47 Desai DK, Moodley J, Naidoo DP. Echocardiographic assessment of cardiovascular hemodynamics in

normal pregnancy. Obstet Gynecol 2004;104(1):20–9. Doi: 10.1097/01.AOG.0000128170.15161.1d.

48 Monga M, Mastrobattista JM. Chapter 7: Maternal cardiovascular, respiratory and renal adaptation to

pregnancy. : Creasy RK, Resnik R, Iams JD, et al., editors. Creasy and Resnik's Maternal-Fetal Medicine:

Principles and Practice. 7 ed. Philadelphia: Elsevier Saunders; 2013. pp. 93–99(96).

49 Langesaeter E. Hemodynamic changes during vaginal delivery in a parturient with no labor pain. Acta

Anaesthesiol Scand 2009;53(3):398–9. Doi: 10.1111/j.1399-6576.2008.01880.x.

50 Bucklin BA. Gerard W. Ostheimer “what's new in obstetric anesthesia” lecture. Anesthesiology 2006:865–

71.

51 Task Force on the Management of Cardiovascular Diseases During Pregnancy of the European Society of

Cardiology. Expert consensus document on management of cardiovascular diseases during pregnancy. Eur

Heart J 2003:761–81.

52 Uebing A, Steer PJ, Yentis SM, Gatzoulis MA. Pregnancy and congenital heart disease. Bmj

2006;332(7538):401–6. Doi: 10.1136/bmj.332.7538.401.

53 Langesæter E, Gibbs M, Dyer RA. The role of cardiac output monitoring in obstetric anesthesia. Curr Opin

Anaesthesiol 2015;28(3):247–53. Doi: 10.1097/ACO.0000000000000190.

54 Langesaeter E, Rosseland LA, Stubhaug A. In reply to: Low-dose spinal anesthesia with low-dose

phenylephrine infusions for cesarean delivery: better but not necessarily best. Anesthesiology

2009;111(1):213–5.

55 Ueland K, Gills RE, Hansen JM. Maternal cardiovascular dynamics. I. Cesarean section under subarachnoid

block anesthesia. Am J Obstet Gynecol 1968;100(1):42–54.

56 Armstrong S, Fernando R, Columb M. Minimally- and non-invasive assessment of maternal cardiac output:

go with the flow! Int J Obstet Anesth 2011:1–11. Doi: 10.1016/j.ijoa.2011.07.006.

57 Dyer RA, James MF. Maternal hemodynamic monitoring in obstetric anesthesia. Anesthesiology

2008;109(5):765–7. Doi: 10.1097/ALN.0b013e31818a3825.

58 James FM, Greiss FC, Kemp RA. An evaluation of vasopressor therapy for maternal hypotension during

spinal anesthesia. Anesthesiology 1970;33(1):25–34.

59 Ralston DH, Shnider SM, DeLorimier AA. Effects of equipotent ephedrine, metaraminol, mephentermine,

and methoxamine on uterine blood flow in the pregnant ewe. Anesthesiology 1974;40(4):354–70.

60 Lee A, Ngan Kee WD, Gin T. A quantitative, systematic review of randomized controlled trials of ephedrine

versus phenylephrine for the management of hypotension during spinal anesthesia for cesarean delivery.

Anesth Analg 2002;94(4):920–6–tableofcontents.

61 Alahuhta S, Räsänen J, Jouppila P, Jouppila R, Hollmén AI. Ephedrine and phenylephrine for avoiding

maternal hypotension due to spinal anaesthesia for caesarean section. Effects on uteroplacental and fetal

haemodynamics. Int J Obstet Anesth 1992;1(3):129–34.

62 Hall PA, Bennett A, Wilkes MP, Lewis M. Spinal anaesthesia for caesarean section: comparison of infusions

of phenylephrine and ephedrine. Br J Anaesth 1994;73(4):471–4.

63 Morgan P. The role of vasopressors in the management of hypotension induced by spinal and epidural

anaesthesia. Can J Anaesth 1994;41(5 Pt 1):404–13. Doi: 10.1007/BF03009863.

64 Thomas DG, Robson SC, Redfern N, Hughes D, Boys RJ. Randomized trial of bolus phenylephrine or

ephedrine for maintenance of arterial pressure during spinal anaesthesia for Caesarean section. Br J

Anaesth 1996;76(1):61–5.

65 Ngan Kee WD, Lau TK, Khaw KS, Lee BB. Comparison of metaraminol and ephedrine infusions for

maintaining arterial pressure during spinal anesthesia for elective cesarean section. Anesthesiology

2001;95(2):307–13.

Page 65: Haemodynamics during Vaginal and Caesarean Delivery in

61

66 Ngan Kee WD, Khaw KS, Ng FF, Lee BB. Prophylactic phenylephrine infusion for preventing hypotension

during spinal anesthesia for cesarean delivery. Anesth Analg 2004;98(3):815–21–tableofcontents.

67 Emmett RS, Cyna AM, Andrew M, Simmons SW. Techniques for preventing hypotension during spinal

anaesthesia for caesarean section. Cochrane Database Syst Rev 2001;48(5 Pt 2):CD002251. Doi:

10.1002/14651858.CD002251.

68 Ngan Kee WD, Khaw KS, Ng FF. Prevention of hypotension during spinal anesthesia for cesarean delivery:

an effective technique using combination phenylephrine infusion and crystalloid cohydration. Anesthesiology

2005;103(4):744–50.

69 Ngan Kee WD, Lee A, Khaw KS, et al. A randomized double-blinded comparison of phenylephrine and

ephedrine infusion combinations to maintain blood pressure during spinal anesthesia for cesarean delivery:

the effects on fetal acid-base status and hemodynamic control. Anesth Analg 2008;107(4):1295–302. Doi:

10.1213/ane.0b013e31818065bc.

70 Ngan Kee WD, Khaw KS, Tan PE, Ng FF, Karmakar MK. Placental transfer and fetal metabolic effects of

phenylephrine and ephedrine during spinal anesthesia for cesarean delivery. Anesthesiology

2009;111(3):506–12. Doi: 10.1097/ALN.0b013e3181b160a3.

71 Ngan Kee WD, Khaw KS, Ng FF. Comparison of phenylephrine infusion regimens for maintaining maternal

blood pressure during spinal anaesthesia for Caesarean section. Br J Anaesth 2004;92(4):469–74. Doi:

10.1093/bja/aeh088.

72 Ngan Kee WD, Khaw KS, Ng FF, et al. A prospective comparison of vasopressor requirement and

hemodynamic changes during spinal anesthesia for cesarean delivery in patients with multiple gestation

versus singleton pregnancy. Anesth Analg 2007;104(2):407–11. Doi:

10.1213/01.ane.0000252461.97656.3e.

73 Ngan Kee WD, Tam YH, Khaw KS, et al. Closed-loop feedback computer-controlled infusion of

phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a preliminary

descriptive study. Anaesthesia 2007;62(12):1251–6. Doi: 10.1111/j.1365-2044.2007.05257.x.

74 Ngan Kee WD, Khaw KS, Ng FF, Tam YH. Randomized comparison of closed-loop feedback computer-

controlled with manual-controlled infusion of phenylephrine for maintaining arterial pressure during spinal

anaesthesia for caesarean delivery. Br J Anaesth 2013;110(1):59–65. Doi: 10.1093/bja/aes339.

75 Ngan Kee WD, Lee SWY, Khaw KS, Ng FF. Haemodynamic effects of glycopyrrolate pre-treatment before

phenylephrine infusion during spinal anaesthesia for caesarean delivery. Int J Obstet Anesth

2013;22(3):179–87. Doi: 10.1016/j.ijoa.2013.03.008.

76 Ngan Kee WD, Khaw KS. Low-dose spinal anesthesia with low-dose phenylephrine infusions for cesarean

delivery: better but not necessarily best. Anesthesiology 2009;111(1):210–1–authorreply213–6. Doi:

10.1097/ALN.0b013e3181a86306.

77 Carvalho B, Dyer RA. Norepinephrine for Spinal Hypotension during Cesarean Delivery: Another Paradigm

Shift? Anesthesiology 2015;122(4):728–30. Doi: 10.1097/ALN.0000000000000602.

78 Allen TK, George RB, White WD, Muir HA, Habib AS. A double-blind, placebo-controlled trial of four fixed

rate infusion regimens of phenylephrine for hemodynamic support during spinal anesthesia for cesarean

delivery. Anesth Analg 2010;111(5):1221–9. Doi: 10.1213/ANE.0b013e3181e1db21.

79 Cooper D, Schofield L, Hynd R, et al. Prospective evaluation of systolic arterial pressure control with a

phenylephrine infusion regimen during spinal anaesthesia for caesarean section. Int J Obstet Anesth

2012;21(3):245–52. Doi: 10.1016/j.ijoa.2012.02.009.

80 Tanaka M, Balki M, Parkes RK, Carvalho JCA. ED95 of phenylephrine to prevent spinal-induced

hypotension and/or nausea at elective cesarean delivery. Int J Obstet Anesth 2009;18(2):125–30. Doi:

10.1016/j.ijoa.2008.09.008.

81 Habib AS. A review of the impact of phenylephrine administration on maternal hemodynamics and maternal

and neonatal outcomes in women undergoing cesarean delivery under spinal anesthesia. Anesth Analg

2012;114(2):377–90. Doi: 10.1213/ANE.0b013e3182373a3e.

Page 66: Haemodynamics during Vaginal and Caesarean Delivery in

62

82 Veeser M, Hofmann T, Roth R, et al. Vasopressors for the management of hypotension after spinal

anesthesia for elective caesarean section. Systematic review and cumulative meta-analysis. Acta

Anaesthesiol Scand 2012;56(7):810–6. Doi: 10.1111/j.1399-6576.2011.02646.x.

83 Butwick AJ, Columb MO, Carvalho B. Preventing spinal hypotension during Caesarean delivery: what is the

latest? Br J Anaesth 2014. Doi: 10.1093/bja/aeu267.

84 James FM, Greiss FC. The use of inflatable boots to prevent hypotension during spinal anesthesia for

cesarean section. Anesth Analg 1973;52(2):246–51.

85 Goudie TA, Winter AW, Ferguson DJ. Lower limb compression using inflatable splints to prevent

hypotension during spinal anaesthesia for caesarean section. Acta Anaesthesiol Scand 1988;32(7):541–4.

86 Sutherland PD, Wee MY, Weston-Smith P, Skinner T, Thomas P. The use of thromboembolic deterrent

stockings and a sequential compression device to prevent spinal hypotension during caesarean section. Int

J Obstet Anesth 2001;10(2):97–102. Doi: 10.1054/ijoa.2000.0798.

87 Adsumelli RSN, Steinberg ES, Schabel JE, Saunders TA, Poppers PJ. Sequential compression device with

thigh-high sleeves supports mean arterial pressure during Caesarean section under spinal anaesthesia. Br J

Anaesth 2003;91(5):695–8.

88 Jørgensen J, Christensen PK, Sonnenschein CH. [Compression stockings as prevention of hypotension in

Cesarean section during spinal anesthesia]. Ugeskr Laeg 1996;158(11):1526–9.

89 Sood PK, Cooper PJ, Michel MZ, Wee MY, Pickering RM. Thromboembolic deterrent stockings fail to

prevent hypotension associated with spinal anaesthesia for elective caesarean section. Int J Obstet Anesth

1996;5(3):172–5.

90 Archer TL, Supresh L, Shapiro AE. Cardiac output measurement, by means of electrical velocimetry, may

be able to determine optimum maternal position during gestation, labour and caesarean delivery, by

preventing vena caval compression and maximising cardiac output and placental perfusion pressure.

Anaesth Intensive Care 2011;39(2):308–11.

91 Jonas MM, Tanser SJ. Lithium dilution measurement of cardiac output and arterial pulse waveform analysis:

an indicator dilution calibrated beat-by-beat system for continuous estimation of cardiac output. Curr Opin

Crit Care 2002;8(3):257–61.

92 Rhodes A, Sunderland R. Arterial Pulse Power Analysis: The LiDCOℳ plus System. Functional

Hemodynamic Monitoring 2004;42(Chapter 14):183–92. Doi: 10.1007/3-540-26900-2_14.

93 O'Brien T. LiDCO—From the laboratory to protocolized goal directed therapy. Annual Reviews in Control

2007;31(2):303–10. Doi: 10.1016/j.arcontrol.2007.09.003.

94 Rosseland LA, Hauge TH, Grindheim G, Stubhaug A, Langesæter E. Changes in Blood Pressure and

Cardiac Output during Cesarean Delivery. Anesthesiology 2013;119(3):541–51. Doi:

10.1097/ALN.0b013e31829416dd.

95 Deegan BMT, O'Connor M, Lyons D, OLaighin G. A new blood pressure and heart rate signal analysis

technique to assess Orthostatic Hypotension and its subtypes. Conf Proc IEEE Eng Med Biol Soc

2007;2007:935–8. Doi: 10.1109/IEMBS.2007.4352445.

96 Brzezinski M, Luisetti T, London MJ. Radial artery cannulation: a comprehensive review of recent anatomic

and physiologic investigations. Anesth Analg 2009;109(6):1763–81. Doi: 10.1213/ANE.0b013e3181bbd416.

97 Dyer RA, Piercy JL, Reed AR, et al. Comparison between pulse waveform analysis and thermodilution

cardiac output determination in patients with severe pre-eclampsia. Br J Anaesth 2010;106(1):77–81. Doi:

10.1093/bja/aeq292.

98 Langesaeter E, Rosseland LA, Stubhaug A. Haemodynamic effects of oxytocin in women with severe

preeclampsia. Int J Obstet Anesth 2011;20(1):26–9. Doi: 10.1016/j.ijoa.2010.10.004.

99 de Wilde RBP, Schreuder JJ, van den Berg PCM, Jansen JRC. An evaluation of cardiac output by five

arterial pulse contour techniques during cardiac surgery. Anaesthesia 2007;62(8):760–8. Doi:

10.1111/j.1365-2044.2007.05135.x.

100 Pittman J, Bar-Yosef S, SumPing J, Sherwood M, Mark J. Continuous cardiac output monitoring with pulse

contour analysis: a comparison with lithium indicator dilution cardiac output measurement. Crit Care Med

2005;33(9):2015–21.

Page 67: Haemodynamics during Vaginal and Caesarean Delivery in

63

101 Pauca A. Pressure Wave Analysis Is Useful to Understand the Pathophysiology of Preeclampsia, but

Perhaps Not the Rapid Changes during Cesarean Delivery. Anesthesiology 2008;108:773–4.

102 Marik PE. Noninvasive cardiac output monitors: a state-of the-art review. J Cardiothorac Vasc Anesth

2013;27(1):121–34. Doi: 10.1053/j.jvca.2012.03.022.

103 Critchley LA, Lee A, Ho AM-H. A critical review of the ability of continuous cardiac output monitors to

measure trends in cardiac output. Anesth Analg 2010;111(5):1180–92. Doi:

10.1213/ANE.0b013e3181f08a5b.

104 Meng L, Phuong Tran N, Alexander BS, et al. The Impact of Phenylephrine, Ephedrine, and Increased

Preload on Third-Generation Vigileo-FloTrac and Esophageal Doppler Cardiac Output Measurements.

Anesth Analg 2011:1. Doi: 10.1213/ANE.0b013e31822649fb.

105 Suehiro K, Tanaka K, Funao T, et al. Systemic vascular resistance has an impact on the reliability of the

Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes. Br J Anaesth

2013;111(2):170–7. Doi: 10.1093/bja/aet022.

106 Oren-Grinberg A. The PiCCO Monitor. Int Anesthesiol Clin 2010;48(1):57–85. Doi:

10.1097/AIA.0b013e3181c3dc11.

107 McNamara H, Barclay P, Sharma V. Accuracy and precision of the ultrasound cardiac output monitor

(USCOM 1A) in pregnancy: comparison with three-dimensional transthoracic echocardiography. Br J

Anaesth 2014;113(4):669–76. Doi: 10.1093/bja/aeu162.

108 National Institute for Clinical Excellence. NICE medical technology guidance 3. CardioQ-ODM oesophageal

doppler monitor. 2011.

109 Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac

output measurement techniques. J Clin Monit Comput 1999;15(2):85–91.

110 Critchley LAH, Huang L. USCOM-window to the circulation: utility of supra-sternal Doppler in an elderly

anaesthetized patient for a robotic cystectomy. J Clin Monit Comput 2014;28(1):83–93. Doi:

10.1007/s10877-013-9499-5.

111 Dyson KS, Shoemaker JK, Arbeille P, Hughson RL. Modelflow estimates of cardiac output compared with

Doppler ultrasound during acute changes in vascular resistance in women. Exp Physiol 2010;95(4):561–8.

Doi: 10.1113/expphysiol.2009.050815.

112 Cnaan A, Laird NM, Slasor P. Tutorial in biostatistics: using the general linear mixed model to analyse

unbalanced repeated measures and longitudinal data. Stat Med 1997.

113 Seltman HJ. Chapter 15: mixed models. Experimental design and analysis; 2012.

114 Thoresen M. Longitudinal Analysis.: Veierød MB, Lydersen S, Laake P, editors. Medical Statistics in Clinical

and Epidemiological Research. 1st ed. Oslo: Gyldendal Akademisk; 2012. pp. 259–86.

115 Winter B. Linear models and linear mixed effects models in R with linguistic applications. arXiv 2013.

116 Bender R, Lange S. Adjusting for multiple testing--when and how? J Clin Epidemiol 2001;54(4):343–9.

117 Perneger TV. What's wrong with Bonferroni adjustments. Bmj 1998;316(7139):1236–8.

118 Trochim W, Donnelly JP, Arora K. Research methods: The essential knowledge base. 2015.

119 Delgado-Rodríguez M, Llorca J. Bias. J Epidemiol Community Health 2004;58(8):635–41. Doi:

10.1136/jech.2003.008466.

120 Bell S. Good Practice Guide No. 11. National Physical Laboratory; 2001.

121 Exell RHB. Error Analysis. Bangkok: King Mongkut's University of Technology Thonburi; 2001.

122 Black N. Why we need observational studies to evaluate the effectiveness of health care. Bmj

1996;312(7040):1215–8.

123 Siddik-Sayyid SM, Taha SK, Kanazi GE, Aouad MT. A randomized controlled trial of variable rate

phenylephrine infusion with rescue phenylephrine boluses versus rescue boluses alone on physician

interventions during spinal anesthesia for elective cesarean delivery. Anesth Analg 2014;118(3):611–8. Doi:

10.1213/01.ane.0000437731.60260.ce.

124 Ilies C, Kiskalt H, Siedenhans D, et al. Detection of hypotension during Caesarean section with continuous

non-invasive arterial pressure device or intermittent oscillometric arterial pressure measurement. Br J

Anaesth 2012;109(3):413–9. Doi: 10.1093/bja/aes224.

Page 68: Haemodynamics during Vaginal and Caesarean Delivery in

64

125 Rout C, Rocke DA. Spinal hypotension associated with Cesarean section: will preload ever work?

Anesthesiology 1999;91(6):1565–7.

126 Magder S. Phenylephrine and Tangible Bias. Anesth Analg 2011;113(2):211–3. Doi:

10.1213/ANE.0b013e318220406a.

127 Gelman S, Mushlin PS. Catecholamine-induced changes in the splanchnic circulation affecting systemic

hemodynamics. Anesthesiology 2004;100(2):434–9.

128 Gelman S. Venous Function and Central Venous Pressure. Anesthesiology 2008;108(4):735–48.

129 Cannesson M, Jian Z, Chen G, Vu TQ, Hatib F. Effects of phenylephrine on cardiac output and venous

return depend on the position of the heart on the Frank-Starling relationship. J Appl Physiol

2012;113(2):281–9. Doi: 10.1152/japplphysiol.00126.2012.

130 Ngan Kee WD, Lee SWY, Ng FF, Tan PE, Khaw KS. Randomized double-blinded comparison of

norepinephrine and phenylephrine for maintenance of blood pressure during spinal anesthesia for cesarean

delivery. Anesthesiology 2015;122(4):736–45. Doi: 10.1097/ALN.0000000000000601.

131 Crystal GJ, Salem MR. The Bainbridge and the “reverse” Bainbridge reflexes: history, physiology, and

clinical relevance. Anesth Analg 2012;114(3):520–32. Doi: 10.1213/ANE.0b013e3182312e21.

132 Ngan Kee WD. Obstetric neuraxial anaesthesia: which vasopressor should we be using? Int J Obstet

Anesth 2003;12(1):55–6–authorreply56–7.

133 Neumark J, Hammerle AF, Biegelmayer C. Effects of epidural analgesia on plasma catecholamines and

cortisol in parturition. Acta Anaesthesiol Scand 1985;29(6):555–9.

134 Lederman RP, Lederman E, Work BA, McCann DS. The relationship of maternal anxiety, plasma

catecholamines, and plasma cortisol to progress in labor. Am J Obstet Gynecol 1978;132(5):495–500.

135 Systrom DM, Lewis GD. Exercise physiology. UpToDate (Internet) 2017 (cited 2017 july 1). Available from:

https://www.uptodate.com/contents/exercise-physiology?source=search_result&search=exercise%20physio

logy&selectedTitle=1~150.

136 Blanks A, Thornton S. The role of oxytocin in parturition. Br J Obstet Gynaecol 2003;110:46–51. Doi:

10.1016/S1470-0328(03)00024-7.

137 Fuchs AR, Romero R, Keefe D, et al. Oxytocin secretion and human parturition: pulse frequency and

duration increase during spontaneous labor in women. Am J Obstet Gynecol 1991;165(5 Pt 1):1515–23.

138 Weis FR, Markello R, Mo B, Bochiechio P. Cardiovascular effects of oxytocin. Obstet Gynecol

1975;46(2):211–4.

139 Anrep von G. On the part played by the suprarenals in the normal vascular reactions of the body. J Physiol

1912;45(5):307–17.

140 Monroe RG, Gamble WJ, LaFarge CG, et al. The Anrep effect reconsidered. J Clin Invest

1972;51(10):2573–83. Doi: 10.1172/JCI107074.

141 Cingolani HE, Pérez NG, Cingolani OH, Ennis IL. The Anrep effect: 100 years later. Am J Physiol Heart Circ

Physiol 2013;304(2):H175–82. Doi: 10.1152/ajpheart.00508.2012.

142 Rowell LB, O' Leary DS. Reflex Control of the Circulation During Exercise - Chemoreflexes and

Mechanoreflexes. J Appl Physiol 1990;69(2):407–18.

143 Ouzounian JG, Elkayam U. Physiologic changes during normal pregnancy and delivery. Cardiol Clin

2012;30(3):317–29. Doi: 10.1016/j.ccl.2012.05.004.

144 Anim-Somuah M, Smyth RM, Jones L. Epidural versus non-epidural or no analgesia in labour. Cochrane

Database Syst Rev 2011;177(7):1465. Doi: 10.1002/14651858.CD000331.pub3.

145 Siu SC, Colman JM. Heart disease and pregnancy. Heart 2001;85(6):710–5.

146 Oakley C. Heart disease in pregnancy. Rev Port Cardiol 2007;26(9):871–80.

147 Langesæter E, Rosseland LA. Maternal hemodynamics during cesarean delivery. Acta Obstet Gynecol

Scand 2006;85(1):126–6.

148 Johnson M, Gatzoulis M, Roos-Hesselink J. Int J Cardiol. Int J Cardiol 2013;168(4):3149–51. Doi:

10.1016/j.ijcard.2013.07.013.

149 Cauldwell M, Klemperer Von K, Uebing A, et al. The management of the second stage of labour in women

with cardiac: A mixed methods study. Int J Cardiol 2016;222:732–6. Doi: 10.1016/j.ijcard.2016.07.272.

Page 69: Haemodynamics during Vaginal and Caesarean Delivery in

65

150 Suntharalingam G, Dob D, Yentis SM. Obstetric epidural analgesia in aortic stenosis: a low-dose technique

for labour and instrumental delivery. Int J Obstet Anesth 2001;10(2):129–34. Doi: 10.1054/ijoa.2000.0720.

151 Opotowsky AR, Siddiqi OK, D'Souza B, et al. Maternal cardiovascular events during childbirth among

women with congenital heart disease. Heart 2012;98(2):145–51. Doi: 10.1136/heartjnl-2011-300828.

152 Mets B. Should Norepinephrine, Rather than Phenylephrine, Be Considered the Primary Vasopressor in

Anesthetic Practice? Anesth Analg 2016;122(5):1707–14. Doi: 10.1213/ANE.0000000000001239.

153 Dennis AT, Dyer RA. Cardiac output monitoring in obstetric anaesthesia. Int J Obstet Anesth 2014;23(1):1–

3. Doi: 10.1016/j.ijoa.2013.11.001.

Page 70: Haemodynamics during Vaginal and Caesarean Delivery in

66

Page 71: Haemodynamics during Vaginal and Caesarean Delivery in

APPENDIX

Study I Table 3. Neonatal Characteristics in Study I

Phe (n = 38)

Leg (n = 38)

Control (n = 36)

P Value

Missing results per group (n)

Apgar 1 10 [1] 10 [1] 10 [1] 0.380 K 0 / 0 / 0 Apgar 5 10 [0] 10 [0] 10 [0] 0.235 K 0 / 0 / 0 UA pH 7.285 [0.054] 7.290 [0.046] 7.272 [0.043] 0.150 A 11 / 13 / 17 BE -0.20 [2.1] -0.40 [1.8] -0.70 [1.8] 0.296 A 16 / 13 / 25 Lac 2.2 [0.6] 2.3 [1.0] 2.6 [0.8] 0.031 K 21 / 18 / 31 PCO2 7.35 [1.14] 7.40 [0.97] 7.77 [1.34] 0.343 A 16 / 13 / 25 PO2 2.15 [0.68] 2.11 [0.85] 1.83 [0.76] 0.507 A 16 / 13 / 25 UV pH 7.344 [0.034] 7.358 [0.027] 7.353 [0.041] 0.138 A 13 / 5 / 11 BE -1.10 [2.1] -1.70 [1.5] -1.60 [1.1] 0.595 A 18 / 8 / 28 Lac 1.75 [0.4] 1.9 [0.3] 2.1 [0.5] 0.001 K 21 / 11 / 31 PCO2 5.78 [0.79] 5.66 [0.72] 6.10 [0.81] 0.050 K 18 / 8 / 28 PO2 3.66 [0.94] 3.98 [1.12] 3.39 [1.21] 0.056 A 18 / 8 / 28

Data are presented as median [interquartile range]. A = 1-Way-Anova. K = Kruskal-Wallis. M = Mann-Whitney U.

Apgar 1 and 5 are scored 1 and 5 minutes after delivery. UA = umbilical artery; UV = umbilical vein; BE = base

excess in mmol/l; Lac = lactate mmol/l; PCO2 = partial pressure of carbon dioxide in kilopascal; PO2 = partial pressure

of oxygen in kilopascal. Statistically significant intergroup differences for UA Lac between groups Phe and Control

(0.007 M), and for UV Lac between groups Phe and Control (0.000 M), Phe and Leg (0.035 M), Leg and Control (0.026

M).

Study II

Table 4. Neonatal Characteristics in Study II

All (n = 20)

Nulliparous (n = 11)

Parous (n = 9)

P Value

Missing results per group (n)

Apgar 1 9 [6-10] 9 [6-10] 10 [8-10] 0.18 1 / 1/ 0 Apgar 5 10 [9-10] 10 [9-10] 10 [10] 0.36 1 / 1/ 0 UA pH 7.210 [0.118] 7.208 [0.077] 7.221 [0.175] 0.84 6 / 4 / 2 BE -4.5 [4.4] -5.7 [2.6] -2.2 [3.9] 0.09 7 / 5 / 2 Lac 5.4 [3.5] 6.0 [4.4] 4.7 [3.2] 0.42 8 / 6 / 2 PCO2 7.83 [2.54] 7.22 [ – ] 7.99 [2.70] 0.54 11 / 8 / 3 PO2 2.38 [1.28] 2.38 [ – ] 2.57 [1.33] 0.54 11 / 8 / 3 UV pH 7.319 [0.089] 7.319 [0.113] 7.343 [0.092] 0.60 5 / 3 / 2 BE -4.7 [5.3] -5.7 [2.9] -2.1 [4.2] 0.05 6 / 4 / 2 Lac 4.70 [3.60] 5.50 [5.00] 4.00 [2.20] 0.57 7 / 5 / 2 PCO2 5.48 [1.66] 5.68 [2.01] 5.48 [1.55] 0.94 10 / 7 / 3 PO2 3.73 [1.59] 3.64 [1.57] 3.89 [1.99] 0.95 10 / 7 / 3

Data are presented as median [interquartile range]. P-values are from Mann-Whitney U for Apgar Values, and from

independent samples t-test for umbilical cord blood gas values. Apgar 1 and 5 are scored 1 and 5 minutes after

delivery. UA = umbilical artery; UV = umbilical vein; BE = base excess in mmol/l; Lac = lactate mmol/l; PCO2 = partial

pressure of carbon dioxide in kilopascal; PO2 = partial pressure of oxygen in kilopascal.

Page 72: Haemodynamics during Vaginal and Caesarean Delivery in

Table 5. Effect of Epidural Analgesia on Haemodynamics in Study II Baseline During contractions Minimum Maximum mean 95% CI p mean 95% CI p mean 95% CI p

CO (l/min) Crude value ref ref ref Effect of Epidural 0.2 -0.2, 0.7 0.3 0.06 -0.4, 0.5 0.8 0.02 -0.5, 0.75 0.7

SV (ml)

Crude value ref ref ref

Effect of Epidural 2 -2, 6 0.3 2 -4, 7 0.6 -4 -11, 3 0.3

HR (beats/min)

Crude value ref ref ref

Effect of Epidural 1 -4, 6 0.6 3 -1, 6 0.2 3 -3, 10 0.3

SVR (dynes/s/cm5)

Crude value ref ref ref

Effect of Epidural -76 -154, 1 0.06 3 1, 6 0.16 -26 -214, 162 0.8

SAP (mmHg)

Crude value ref ref ref

Effect of Epidural 3 -2, 9 0.2 -13 -56, 29 0.5 -0.3 -9, 8 0.9

Mean values are estimated effects of epidural analgesia on the reference crude mean value. Each haemodynamic

variable was analysed separately within each stratum (baseline, minimum, maximum), with marginal linear models

that allowed for dependency between repeated measures within parturients. The model assessed the haemodynamic

variables as dependent factors, and stage, parity, epidural analgesia, and oxytocin as independent factors. SVR:

systemic vascular resistance; SAP: systolic arterial pressure. Epidural = epidural analgesia. CI: confidence intervals.

P: P value. P values <0.05 were considered statistically significant.

Table 6. Effect of Epidural Analgesia on Pain and Sensory Level in Study II

Parturients with Epidural

p-value (n=12)

NRS during contractions before start of Epidural 7.4 (1.3) - NRS during contractions after start of Epidural 3.8 (2.0) - Reduction in NRS after start of Epidural 3.6 (1.9) <0.001 Sensory level after start of Epidural 9 (1) -

Data are presented as mean (SD). Comparison of NRS before and after start of epidural analgesia was performed

with paired samples t-test (significance level = 0.05). NRS = numeric rating scale for pain (0-10). Epidural = epidural

analgesia. Sensory level indicates the uppermost thoracic dermatome with bilaterally reduced sensitivity to cold,

measured by ethyl chloride spray within the first hour after start of epidural analgesia.

Page 73: Haemodynamics during Vaginal and Caesarean Delivery in

Errata List. Haemodynamics during Vaginal and Caesarean Delivery in Healthy Parturients

Page

Line

Original Text

Type of Correction

Corrected Text

30 6 to 10 Original text will not be changed. Variables are listed in row order: CO, SV, SVR, HR, SAP

Cpltf Original text remains unchanged. Variables are listed in row order: SAP, HR, SVR, SV, CO

30 13 to 17 Original text will not be changed. Variables are listed in order: CO, SV, SVR, HR, SAP

Cpltf Original text remains unchanged. Variables are listed in row order: SAP, HR, SVR, SV, CO

57 20 positioning and volume state Cor positioning and volume state;

This Errata List displays corrections between the original version and the printed version of the PhD Thesis

“Haemodynamics during Vaginal and Caesarean Delivery in Healthy Parturients”. Cpltf: correction of page layout or

text format. Cor: Correction of text.

Page 74: Haemodynamics during Vaginal and Caesarean Delivery in

AmAbend wird man klug für den vergangenen Tag, doch niemals klug genug für den der kommen mag.

Friedrich Rückert (1788-1866)

Tonight, you are wise for the day that has gone, but not yet wise enough for the day that will come.

Free translation after Friedrich Rückert