HABEEB A R C H I T E C T S ASSOCIATES & 150 LONGWATER DR NORWELL, MA 02061-1618 OFFICE: 781.871.9804 FAX: 78.871.9805 habeebarch.com SCALE: PROJECT NO: DATE: DRAWN BY: CHECKED BY: 1 A 1 2 3 4 5 B C D 2 3 4 5 CONSULTANT NORTH ARROW KEY PLAN STAMP MSBA ACCELERATED REPAIR PROGRAM WINDOWS, DOORS & SIDING REPLACEMENT 1/23/2018 11:11:59 AM A-001 TITLE SHEET 1614.03 12/13/17 cjp SB 464 PLYMOUTH STREET HALIFAX, MA, 02338 HALIFAX ELEMENTARY SCHOOL HALIFAX ELEMENTARY SCHOOL DRAWING LIST GENERAL A-001 TITLE SHEET A-002 SITE PLAN A-003 GENERAL NOTES & LEGEND ARCHITECTURAL DEMOLITION AD-201 EXTERIOR ELEVATIONS - DEMOLITION AD-202 EXTERIOR ELEVATIONS - DEMOLITION AD-203 EXTERIOR ELEVATIONS - DEMOLITION AD-204 EXTERIOR ELEVATIONS - DEMOLITION AD-501 WINDOW TYPES - DEMOLITION AD-502 DOOR AND FRAME TYPES - DEMOLITION AD-511 WINDOW & STOREFRONT DETAILS - DEMOLITION AD-512 WINDOW & STOREFRONT DETAILS - DEMOLITION AD-513 WINDOW DETAILS - DEMOLITION AD-521 DOOR DETAILS - DEMOLITION AD-531 MISC DETAILS - DEMOLITION AD-541 WALL DETAILS - DEMOLITION ARCHITECTURE A-101 FLOOR PLAN A-201 EXTERIOR ELEVATIONS A-202 EXTERIOR ELEVATIONS A-203 EXTERIOR ELEVATIONS A-204 EXTERIOR ELEVATIONS A-210 ENLARGED EXTERIOR ELEVATIONS A-501 WINDOW TYPES - NEW A-502 STOREFRONT - DOOR TYPES & DOOR SCHEDULE A-511 WINDOW & STOREFRONT DETAILS A-512 WINDOW & STOREFRONT DETAILS A-513 WINDOW DETAILS A-521 DOOR DETAILS A-531 MISC DETAILS A-541 WALL DETAILS A-551 REFLECTED SOFFIT PLAN 464 PLYMOUTH ST HALIFAX, MA 02338 MSBA PROJECT # 201601180005 CONSTRUCTION DOCUMENTS DECEMBER 13, 2017 MSBA ACCELERATED REPAIR PROGRAM WINDOWS, DOORS AND SIDING REPLACEMENT ARCHITECT HABEEB & ASSOCIATES ARCHITECTS 150 LONGWATER DRIVE NORWELL, MA 02061 TEL: 781 - 871 - 9804 / FAX: 781 - 871 - 9805 www.habeebarch.com OWNER'S PROJECT MANAGER THE VERTEX COMPANIES, INC. 400 LIBBEY PARKWAY WEYMOUTH, MA 02189 TEL: 781 - 952 - 6000 [email protected] LOCUS PLAN (NOT TO SCALE) PROJECT LOCATION OWNERSHIP AUTHORITY TOWN OF HALIFAX 499 PLYMOUTH STREET HALIFAX, MA 02338 TEL: 781 - 293 - 6557 R E V I S I O N M A R K D A T E R E V I S I O N S 1 2 / 1 3 / 1 7 C O N S T R U C T I O N D O C U M E N T S ADDENDUM 1 - 12/21/17 ADDENDUM 2 - 12/26/17 COORDINATION - 1/5/18

Upload: others

Post on 02-May-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HALIFAX ELEMENTARY SCHOOL

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

1/2

3/2

018

11:1

1:5

9 A

M

A-001

TITLE SHEET

1614.03

12/13/17

cjp

SB

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

HALIFAX ELEMENTARY SCHOOL

DRAWING LISTGENERAL

A-001 TITLE SHEET

A-002 SITE PLAN

A-003 GENERAL NOTES & LEGEND

ARCHITECTURAL DEMOLITION

AD-201 EXTERIOR ELEVATIONS - DEMOLITION

AD-202 EXTERIOR ELEVATIONS - DEMOLITION

AD-203 EXTERIOR ELEVATIONS - DEMOLITION

AD-204 EXTERIOR ELEVATIONS - DEMOLITION

AD-501 WINDOW TYPES - DEMOLITION

AD-502 DOOR AND FRAME TYPES - DEMOLITION

AD-511 WINDOW & STOREFRONT DETAILS - DEMOLITION

AD-512 WINDOW & STOREFRONT DETAILS - DEMOLITION

AD-513 WINDOW DETAILS - DEMOLITION

AD-521 DOOR DETAILS - DEMOLITION

AD-531 MISC DETAILS - DEMOLITION

AD-541 WALL DETAILS - DEMOLITION

ARCHITECTURE

A-101 FLOOR PLAN

A-201 EXTERIOR ELEVATIONS

A-202 EXTERIOR ELEVATIONS

A-203 EXTERIOR ELEVATIONS

A-204 EXTERIOR ELEVATIONS

A-210 ENLARGED EXTERIOR ELEVATIONS

A-501 WINDOW TYPES - NEW

A-502 STOREFRONT - DOOR TYPES & DOOR SCHEDULE

A-511 WINDOW & STOREFRONT DETAILS

A-512 WINDOW & STOREFRONT DETAILS

A-513 WINDOW DETAILS

A-521 DOOR DETAILS

A-531 MISC DETAILS

A-541 WALL DETAILS

A-551 REFLECTED SOFFIT PLAN

464 PLYMOUTH STHALIFAX, MA 02338

MSBA PROJECT # 201601180005

CONSTRUCTION DOCUMENTS DECEMBER 13, 2017

MSBA ACCELERATED REPAIR PROGRAMWINDOWS, DOORS AND SIDING REPLACEMENT

ARCHITECTHABEEB & ASSOCIATES ARCHITECTS150 LONGWATER DRIVENORWELL, MA 02061TEL: 781-871-9804 / FAX: 781-871-9805www.habeebarch.com

OWNER'S PROJECT MANAGERTHE VERTEX COMPANIES, INC.400 LIBBEY PARKWAYWEYMOUTH, MA 02189TEL: [email protected]

LOCUS PLAN (NOT TO SCALE)

PROJECT

LOCATION

OWNERSHIP AUTHORITY TOWN OF HALIFAX499 PLYMOUTH STREET HALIFAX, MA 02338TEL: 781-293-6557

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

ADDENDUM 1 - 12/21/17

ADDENDUM 2 - 12/26/17

COORDINATION - 1/5/18

Page 2: HALIFAX ELEMENTARY SCHOOL

UP UP

UP

UPUP UP

UP

DN

DN

UP

UP

UP

PLYMOUTH STREET

PARKING

TOWN LIBRARYPARKING

MAIN ENTRANCE

PARKING

PROPE

RTY

LIN

E

EXISTING PLAYGROUND

EXIT

EXIT

CLASSROOM

CLASSROOM CLASSROOM SPECIALEDUCATION

STORAGE

TOILET

CLASSROOM

CLASSROOMCLASSROOM

MEDIACENTER

SPEECHROOM

BOYS

STORAGE

GIRLSCLASSROOM CLASSROOM CLASSROOOM

OFFICE

STORAGE

CLASSROOM

SPECIALEDUCATION

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CAFETERIA

DISHWASHING

STO.

CAFETERIA

KINDERGARTEN

MEETINGROOM

STAFFLOUNGE

STORAGE

DIRECTORSOFFICE

ELEV.

REMEDIAL

STAIR

CLASSROOMOFFICE

OFFICETOIL.

CONFERENCE

STO.

HEALTH

EXAM RECOV.

ADMIN

KINDERGARDEN KINDERGARDEN KINDERGARDEN

CLASSROOM CLASSROOM

MENS

WOMENS

JAN

TOIL. DISHWASHING

KITCHEN

WOM.MENS

JANITORSROOMBOYS

GIRLS

JAN.

SPECIALEDUCATION

REMEDIALCLASSROOM

CLASSROOM

CLASSROOM

ARTROOM

MUSICROOM

GYM

STOR.

OFFICE GIRLS

BOYS

ST.

ST.

OFF.

SIDEROOM

WOM.

PERIODICALS

STACKAREA

REFERENCESTACKAREA

CIRCULATION ENTRYVESTIB.

CHILDRENSROOM

STORYTELLING

WOM.MENMECH

YOUNGADULTS

LOBBY

PLATFORM

LOBBY

TOILETSTO

LIFTROOM

STORAGESTORAGE

VESTIBULE

TOIL.

STO. STO.TOILET TOILET

STO.TOILET

ELEC.CLO.ELEC. CLO

ELEC.CLO.

CORRIDOR

STO. STO. STO.STORAGE

ST.

JAN. TOIL.CORRIDOR STAIR

PLATFORM

STORAGE STORAGE

STAIRS

CO

NT

RA

CT

OR

S

TA

GIN

G A

RE

A

EXISTING GRASS, SEE

NOTE #7

PROVIDE TEMPORARY FENCE WITH GATE

PROVIDE TEMPORARY FENCE WITH GATE

PROVIDE TEMPORARY FENCE WITH GATE

SCHOOL DELIVERIES

EXISTING ACCESS ROAD

EXISTING FENCE

BALL FIELDS

TENNIS COURTSEXIS

TING

RO

AD

KINDEGARDEN

COURTYARD

EXIT

EXIT

EXIT

EXITEXIT

EXIT

EXIT

EXISTING GATE

EXISTING GATE

EXISTINGDUMPSTER

EXISTINGFENCE & GATE

N.I.C

AREA FOR TEMPORARY PLACEMENT OF STORAGE TRAILERS

GENERAL NOTES

1 ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE MASS STATE BUILDING CODE.

2 ALL CONDITIONS ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE.

3 THE GENERAL CONTRACTOR SHALL COOPERATE WITH AND COORDINATE THEIR WORK LOCATIONS AND SCHEDULE WITH THE OWNER AND OTHER CONTRACTORS WORKING ON SITE.

4 THE GENERAL CONTRACTOR SHALL PROTECT EXISTING CONSTRUCTION AND SITE, AND REPAIR ALL DAMAGES DUE TO THEIR CONSTRUCTION ACTIVITIES.

5 THE GENERAL CONTRACTOR SHALL PROVIDE SAFE AND PROTECTED ACCESS TO ALL BUILDING ENTRANCES AT ALL TIMES FOR THE BUILDING OWNER AND STAFF.

6. INSTALL LOAM AND SEED AT ANY AREAS OF LAWN DAMAGED BY CONTRACTOR'S EQUIPMENT OR WORK.

7. FINAL TEMPORARY FENCE AND GATE LAYOUT TO BE COORDINATED AND APPROVED BY OWNER PRIOR TO INSTALLATION.

8. TOWN LIBRARY TO REMAIN OPEN DURING SUMMER CONSTRUCTION. WORK AT LIBRARY IS NOT IN CONTRACT (N.I.C).

9. CONTRACTOR TO VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD.

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

WING A

WING B

WING C

KEY PLAN KEY PLAN

As indicated

1/2

3/2

018

11:1

2:0

5 A

M

A-002

SITE PLAN

1614.03

12/13/17

JS

SB/LM

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1" = 30'-0"A1

SITE PLAN /FIRST FLOOR PLAN0'

4' 8' 16'

1/8" = 1'-0" 1992 ADDITION

1964ADDITION

1992 ADDITION

1958 BUILDING

1992 ADDITION

COURTYARD

1975 TOWN

LIBRARY (NIC)

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 3: HALIFAX ELEMENTARY SCHOOL

EXISTING WINDOWS OR CURTAINWALL SYSTEMS & TRIM TO BE REMOVED

NEW FIXED & OPERABLE ALUMINUM WINDOW W/ SECURITY AND/OR INSECT SCREEN; SEE WINDOW TYPES FOR VARIATIONS

PROJECTING ALUMINUM WINDOW W/ SECURITY AND/OR INSECT SCREEN; SEE WINDOW TYPES FOR VARIATIONS

EXISTING LOUVER TO REMAIN

ALUMINUM LOUVER IN WINDOW TYPE SASH OR FRAME

EXISTING DOOR TO BE REMOVED

NEW OPERABLE DOOR; SEE ELEVATIONS FOR DOOR TYPES

DEMOLITION NEW

A A

# #

SH

LF

LF LF

LS

FA / HS

RWL

HB

JB

DB

EB

VH

FDC

DOOR TYPE INDICATOR-SEE EXTERIOR ELEVATIONS AND DOOR TYPES SHEET

WINDOW & STOREFRONT TYPE INDICATOR-SEE EXTERIOR ELEVATIONS AND WINDOW TYPES SHEET

WINDOW SHADES WITH LOW POINT OF OPERATING HARDWARE AT 5'-6" A.F.F. MIN. ANY REQUIRED LOOPS OR CHAINS TO BE BREAK-AWAY TYPE.

EXTERIOR LIGHT FIXTURE

EXTERIOR WALL SCONCE LIGHT FIXTURE ON PVC PANEL

LOUD SPEAKER

GONG (BELL)

FIRE ALARM HORN STROBE

FIRE DEPARTMENT CONNECTION

RAIN WATER LEADER

HOSE BIB

JUNCTION BOX (ELECTRICAL)

DOOR BELL

ELECTRICAL DUPLEX RECEPTACLE

VENT HOOD / DRYER VENT

DRY SPRINKLER SYSTEM DRAINFP DR

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

1/4" = 1'-0"

1/2

3/2

018

11:1

2:0

5 A

M

A-003

GENERAL NOTES &LEGEND

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

THE FOLLOWING DEMOLITION WORK NOTES ARE TYPICAL TO MULTIPLE CONDITIONS THROUGHOUT THIS PROJECT AND ARE INCLUSIVE OF THE PROJECT SCOPE OF WORK. REFER TO DEMOLITION WINDOW AND DOOR TYPES FOR LOCATIONS OF OTHER SPECIFIC WORK:1. SEE SPECIFICATION DIVISION 00 FOR EXISTING HAZARDOUS MATERIAL REPORT.

2. SEE SPECIFICATION SECTION 013543 ENVIRONMENTAL PROCEDURES FOR SCOPE OF WORK RELATIVE TO HAZARDOUS MATERIALS, TYPICAL.

3. REMOVE AND PROPERLY DISPOSE OF EXISTING WINDOW & DOOR ASSEMBLIES AT ALL EXTERIOR OPENINGS, INCLUDING: SCREENS, FRAMES, GLAZING, LOUVERS, PANELS, GLAZING COMPOUNDS, FLASHING, BLOCKING, SEALANTS, INSULATION / WOOD PANELING THAT IS ATTACHED TO THE WINDOW ASSEMBLY, TYPICAL (TYP).

4. WHERE REQUIRED, CAREFULLY DETACH CEILING TRACK / SUPPORT FROM WINDOW ASSEMBLY, PROVIDE TEMPORARY SUPPORT AS REQUIRED. PROVIDE NEW SUPPORT FOR CEILING, REPLACE, REPAIR, PAINT CEILING, AND/OR CEILING TILES WITH THE SAME QUALITY AND FINISHES OR EQUAL TO FINISHES IF DAMAGED, TYPICAL.

5. REMOVE AND PROTECT EXISTING UNIT VENTILLATOR GRILLES (UVG), RESET AND REINSTALL AS REQUIRED. THE CONTRACTOR SHALL MOVE ALL FURNITURE THAT MAY INTERFERE WITH WORK AN APPROPRIATE DISTANCE AWAY FROM WORK AREA. ALL FURNITURE SHALL BE COVERED AND PROTECTED FROM ANY DAMAGE.

6. CONTRACTOR SHALL REPLACE ALL WINDOW STOOLS, APRONS, WOOD TRIM AND CEILINGS DAMAGED DURING DEMOLITION AND CONSTRUCTION.

7. PRIOR TO WINDOW REMOVAL CONTRACTOR SHALL NOTIFY ARCHITECT / OWNER OF ANY DAMAGES THAT MAY AFFECT OR INTERFERE WITH THE WINDOW REPLACEMENT PROCESS.

8. REMOVE ALL EXISTING SHADES AND ROLLERS, INCLUDING CORDS, MOUNTING BRACKETS & ALL FASTENERS, TYPICAL.

9. REMOVE EXISTING WOOD STOP JAMB AND HEAD TRIM AS REQUIRED TO REMOVE ALL CLIP ANCHORS AND FASTENERS, TYPICAL.

10. REMOVE EXISTING EXPOSED OR CONCEALED SEALANTS ON HEADS, JAMBS AND SILLS OF EXISTING WALL CONSTRUCTION AT PERIMETERS OF WINDOW OPENINGS THAT WILL REMAIN EXPOSED AFTER NEW WINDOW SYSTEM PANNING AND TRIM IS INSTALLED OR THAT WHICH INTERFERES WITH WINDOW SYSTEM INSTALLATIONS. SEALANTS SHALL BE REMOVED FLUSH AND SMOOTH TO FACE OF EXISTING WALL CONSTRUCTION SURFACES, TYPICAL.

11. REMOVE EXISTING LOUVER UNITS. WORK TO INCLUDE DISCONNECTION OF INTERIOR SHEET METAL DUCT CONNECTIONS FROM INTERIOR OF LOUVERS, AT UNIT VENTILATORS AND OTHER VENTILATING DUCTWORK OR EQUIPMENT, AND SALVAGE FOR RE-INSTALLATION.

12. COORDINATE DOOR SECURITY ALARM SYSTEM REQUIREMENTS WITH THE OWNER BEFORE DEMOLITION WORK ON DOORS COMMENCES. PROTECT EXISTING ELECTRONIC SECURITY ALARM DOOR CONTACTS AND WIRING ON AND WITHIN EXISTING FRAMES, TYPICAL. REMOVE EXISTING SECURITY ALARM DEVICES AND WIRING LOCATED AT ALL EXTERIOR DOORS, FRAMES & STOREFRONT SYSTEMS. CAREFULLY DISCONNECT WIRING IN CONCEALED LOCATIONS.

13. REMOVE COMPLETE, EXISTING WOOD DOORS, FRAMES AND ALL ATTACHED DOOR OPERATING AND WEATHERSTRIPPING HARDWARE ON DOORS AND FRAMES INDICATED ON DRAWINGS. DEMOLITION WORK TO INCLUDE REMOVAL OF EXISTING CLOSERS, CLOSER MOUNTING BRACKETS, DOOR OPERATING HARDWARE AND STRIKES, OFFSET PIVOT OR SURFACE MOUNTED HINGES, FLOOR THRESHOLDS AND FLOOR CLOSER THRESHOLDS AND ALL HARDWARE FASTENERS, TYPICAL.

14. REMOVE EXISTING ELECTRIC STRIKE AND WIRELESS DOOR RELEASE SYSTEM ON DOORS AND FRAMES. REMOVE SYSTEM WIRING SURFACE-MOUNTED ON EXISTING FRAMES. REMOVE AND SALVAGE FOR REINSTALLATION, EXISTING SYSTEM POWER AND TRANSMITTER PANELS FROM FRAMES OR ADJACENT WALLS INCLUDING SURFACE WIRING RACEWAYS ON FRAMES AND CONDUIT ON WALLS. PATCH AND PAINT WALLS AT REMOVED DEVICES AND WIRING, TYPICAL.

15. REMOVE AND SALVAGE FOR REINSTALLATION EXISTING ACOUSTICAL CEILING TILE PANELS AND METAL CEILING GRID SYSTEM TO ALLOW REMOVAL OF EXISTING DOOR FRAME SYSTEMS, TYPICAL.

16. REMOVE COMPLETE, EXISTING RECESSED OFFSET-PIVOT FLOOR CLOSER OPERATORS AND HOUSINGS CAST INTO EXISTING CONCRETE OR TERRAZZO FLOORING. REMOVE ANCHORS AND FASTENERS, AND RUST AND OIL RESIDUE WITHIN RECESS OF OPENING. REMOVE LOOSE OR BROKEN ADJACENT CONCRETE AND FINISHED FLOORING MATERIALS, TYPICAL.

17. REMOVE ALL EXISTING SIDING, TRIM, AND AIR/MOISTURE BARRIER DOWN TO EXISTING SHEATHING UNLESS NOTED OTHERWISE.

18. REMOVE EXISTING WINDOW SHADES.

19. REMOVE ALL DRY SPRINKLER SYSTEM DRAINS EXPOSED AT THE EXTERIOR WALL. FILL VOID WITH INSULATION.

THE FOLLOWING NEW WORK NOTES ARE TYPICAL TO MOST CONDITIONS THROUGHOUT THIS PROJECT AND ARE INCLUSIVE OF THE PROJECT SCOPE OF WORK. REFER TO WINDOW AND DOOR TYPES AND DETAILS FOR LOCATIONS OF OTHER SPECIFIC WORK:

1. THE INFORMATION SHOWN ON THE ELEVATIONS WAS COMPILED FROM VARIOUS SOURCES AND MAY NOT REFLECT THE ACTUAL CONDITIONS AT THE TIME OF CONSTRUCTION. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD.

2. ALL OPENING DIMENSIONS SHOWN ARE PLUS OR MINUS (±) REGARDLESS OF HOW THEY ARE SHOWN OR INDICATED IN DIMENSION LINE AND SHALL BE VERIFIED IN THE FIELD (VIF) PRIOR TO FABRICATION.

3. ANY CONDITION NOT FOUND DETAILED SHALL BE CONSTRUCTED IN A MANNER SIMILAR TO THAT OF THE WINDOW MANUFACTURER'S TYPICAL (TYP) DETAILS. NOTIFY ARCHITECT OF ANY CONDITIONS DISCOVERED WHICH MIGHT REQUIRE AESTHETIC CONSIDERATION OR DETAILING. ARCHITECT SHOULD BE NOTIFIED OF ANY CONDITIONS NOT DETAILED.

4. THE CONTRACTOR SHALL REMOVE AND REPLACE ONLY THE OPENINGS WHICH CAN BE INSTALLED COMPLETE EACH DAY INCLUDING WINDOWS, DOORS, FRAMES, PANNING, SASHES, GLAZING, PANELS, AND SEALANT.

5. REPLACE ALL INTERIOR AND EXTERIOR FINISH MATERIALS EXPOSED TO VIEW WHICH WERE DAMAGED BY WINDOW REPLACEMENT. REPLACEMENT MATERIALS SHALL MATCH EXISTING MATERIALS AND FINISH.

6. CONTRACTOR SHALL REINSTALL AND RECONNECT ANY SECURITY SENSORS AND SHALL COORDINATE DOOR AND WINDOW REPLACEMENT WITH THE OWNER SO THAT THESE DEVICES CAN BE REINSTALLED ON THE SAME DAY AS REPLACEMENT. REINSTALL EXISTING CONCEALED SECURITY ALARM DEVICES & WIRING FOR ALL NEW DOORS, FRAMES AND STOREFRONT SYSTEMS. CONNECT TO EXISTING SECURITY ALARM SYSTEM. CONFIRM OPERATION OF SECURITY EQUIPMENT AT EACH OPENING AFFECTED.

7. REPAIR / RESET & FASTEN LOOSE EXISTING BLOCKING, FLASHING AND OTHER ITEMS AT OPENINGS PRIOR TO INSTALLATION OF NEW WINDOW OR DOOR FRAMES.

8. ALL ELECTRICAL WORK RELATED TO NEW WINDOW, DOOR AND SIDING INSTALLATIONS SHALL BE DONE BY A LICENSED ELECTRICIAN.

9. ALL PLUMBING WORK RELATED TO NEW WINDOW, DOOR AND SIDING INSTALLATIONS SHALL BE DONE BY LICENSED PLUMBER.

10. SECURITY AND/OR INSECT SCREENS TO BE INSTALLED AT ALL OPERABLE WINDOW OPENINGS.

11. SALVAGE ALL EXIT DOOR SIGNS AND REINSTALL IN APPROXIMATELY THE SAME LOCATION AS PREVIOUSLY INSTALLED. SIGNS SHOULD BE ATTACHED TO EITHER A METAL PANEL OR MULLION IN AN APPROPRIATE FASHION.

12. PROVIDE SETS OF NEW INDIVIDUAL 4" W X 8" H ADHESIVE-APPLIED VINYL SIGNAGE WITH 6" H NUMERALS, ONE FOR EACH SIDE OF EVERY EXTERIOR DOOR. REFER TO SPECIFICATIONS.

13. PROVIDE NEW SELF-ADHERING BITUMINOUS MEMBRANE CONTINUOUS STRIP FLASHING FOR ENTIRE PERIMETER OF ALL WINDOW OPENINGS TO COVER ALL NEW OR EXISTING EXPOSED WOOD BLOCKING. LAP ALL FLASHING ONTO ADJACENT EXISTING HEAD, JAMB AND SILL CONSTRUCTION TO WITHIN 1/2” OF OUTERMOST FACE OF ALUMINUM PANNING OR WINDOW FRAMING. FLASHING SHALL BRIDGE ALL GAPS IN BLOCKING AND EXISTING WALL ASSEMBLIES TO PROVIDE A COMPLETE AIR BARRIER ACROSS EXISTING WALL CAVITIES AND BETWEEN THE EXISTING WALL CONSTRUCTION AND THE WINDOW OPENINGS, TYPICAL.

14. PAINT UNIT VENTILLATOR GRILLES PRIOR TO REINSTALLATION. REINSTALL EXISTING UNIT VENTILLATOR GRILLE, SET IN BED OF SEALANT. INCLUDE ALL FASTENERS, SHIMS AND SEALANTS. WORK TO INCLUDE RECONNECTION TO EXISTING INTERIOR SHEET METAL DUCTS AT INTERIOR OF LOUVERS WITH NEW SHEET METAL DUCT EXTENSIONS AT UNIT VENTILATORS AND OTHER VENTILATING DUCTWORK OR EQUIPMENT. PAINT EXISTING AND NEW EXPOSED DUCTWORK. INTERIOR WALL FINISHES AT WINDOW OPENINGS AFFECTED BY NEW WORK SHALL BE PATCHED AND PAINTED TO MATCH EXISTING, TYPICAL.

15. PROVIDE NEW BOND BREAKING AND BACKING MATERIALS IN OPEN JOINTS, AND EXTERIOR SEALANT AT PERIMETERS OF ALL NEW WINDOW LIMITS. SEALANTS SHALL BE TOOLED SMOOTH AND FLUSH TO FACE OF PANNING AND CONCAVED ONTO EXISTING WALL CONSTRUCTION SURFACES, TYPICAL.

16. PROVIDE NEW LIGHT-FILTERING FABRIC ROLLER-TYPE WINDOW SHADES INCLUDING MANUAL CLUTCH CHAIN OPERATORS AT ALL WINDOWS SHOWN ON PLANS. PROVIDE ALL MOUNTING BRACKET HARDWARE AND FASTENERS. ROLLER SHADE BRACKETS SHALL BE INSTALLED ON NEW WINDOW FRAMING AT HEIGHT OF EXISTING FINISHED CEILINGS WHERE CEILINGS ABUT WINDOW FRAMING OR INSTALLED ON EXISTING WALL OR CEILING CONSTRUCTION ABOVE WINDOWS AND SHALL EXTEND DOWN TO WINDOW SILL HEIGHTS OR TO TOP OF OTHER RESTRICTIONS, TYPICAL.

17. REINSTALL COMPLETE, REMOVED EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEMS TO MATCH EXISTING, AFTER INSTALLATION OF NEW WINDOW FRAMING SYSTEMS AND TRIM. REPLACE DAMAGED EXISTING ACOUSTICAL CEILING CONSTRUCTION TO MATCH EXISTING.

18. PATCH AND PAINT ALL EXISTING INTERIOR WALLS AND REPAIR EXISTING FINISHED CEILING FINISHES IN ROOMS AND AT WINDOW ALCOVE OPENINGS AFFECTED BY NEW WORK TO MATCH EXISTING, TYPICAL.

19. CLEAN AND PREPARE EXISTING SUB-FLOOR MATERIALS OF RUST AND OIL RESIDUE WITHIN FLOOR OPENINGS AT REMOVED RECESSED FLOOR CLOSER HOUSINGS. PATCH AND FILL SOLID EXISTING FLOOR OPENING RECESSES WITH ACRYLIC-MODIFIED WATER-RESISTANT CEMENT GROUT, FILL EXISTING FLOOR OPENING RECESSES LEVEL AND SMOOTH TO LINES OF EXISTING ADJACENT FLOORING SURFACES. PATCH EXISTING ADJACENT FLOORING DAMAGED BY REMOVAL WORK TO MATCH EXISTING MATERIALS, TYPICAL.

20. COORDINATE DOOR SECURITY ALARM SYSTEM REQUIREMENTS WITH THE OWNER BEFORE NEW WORK ON FRAMES COMMENCES. REINSTALL EXISTING ELECTRONIC SECURITY ALARM DOOR CONTACTS AND PROVIDE NEW WIRING WITHIN NEW FRAMES, CONNECTING TO EXISTING SECURITY SYSTEM WIRING, TYPICAL.

21. PROVIDE NEW WIRING TO NEW CARD READER LOCATIONS SHOWN ON PLAN. RUN WIRING BACK TO EXISTING SECURITY PANEL.

DEMOLITION WORK GENERAL NOTES: NEW WORK GENERAL NOTES:

1. ALL WORK SHALL BE PERFORMED BY OR UNDER THE SUPERVISION OF THE GENERAL CONTRACTOR AWARDED THE CONTRACT. WORK SHALL INCLUDE BUT NOT BE LIMITED TO ALL RELATED SIDING, PLUMBING, ELECTRICAL AND MECHANICAL SCOPE IN CONJUNCTION WITH THE WINDOW AND DOOR REPLACEMENT PROJECT SCOPE. MINOR PATCHING AND REPAIR OF EXTERIOR AND INTERIOR FINISHES EFFECTED BY THE REMOVAL AND INSTALLATION OF THE WINDOW AND DOOR UNITS IS REQUIRED FOR A FINISHED APPEARANCE THAT MATCHES EXISTING CONDITIONS.

2. PENETRATIONS (ELECTRICAL, FIRE ALARM OR GAS) AT INSULATED PANELS SHALL NOT COMPROMISE ANY WINDOW UNIT.

3. ALL EXTERIOR DOORS ARE ALARMED; CONNECT TO EXISTING SECURITY ALARM SYSTEM. THE CONTRACTOR SHALL TEST ALARM SYSTEM IN-FRONT-OF THE OWNER TO SHOW THAT NEW ALARM DEVICES AND WIRING ARE FUNCTIONING AND CONNECTED TO EXISTING SYSTEM. SYSTEM MUST BE FULLY OPERATIONAL UPON PROJECT CLOSEOUT.

4. STORAGE TRAILERS WILL BE ALLOWED ON SITE. OWNER TO APPROVE LOCATION PRIOR TO PLACEMENT

GENERAL NOTES:

CB CORNER BOARD

UVG UNIT VENTILATOR GRILL

ABREVIATION LIST:

BUILDING ELEVATION LEGEND:

VERTICALVERT.REINFORCINGREINF.

MACH. MACHINE

FULL SIZE

CORR. CORRIDOR

CABINET UNIT HEATER

DIRECT APPLIED FINISH

SYSTEM

D.F.

DET.

DRINKING FOUNTAIN

DETAIL

C.R.

CUBICCU.

C.U.H.

CSK.

D.A.F.S.

D.A.

CRS.

COUNTERSINK

COLD ROLLED

COURSES

DOUBLE ACTING

G.C. GENERAL CONTRACTOR

WIND. WINDOW

MISC. MISCELLANEOUS

M.O.

MLDG.

MASONRY OPENING

MOLDING

GR. GRADE

GL. GLASS

WHITE BOARD (MAKER BOARD)W.B.

SECTION

SCHEDULE

SECT.

SCHED.

MAT.

MAX.

M.D.

MIN.

MFGR.

MECH.

MEMBR.

MAS. MASONRY

MECHANICAL

MEMBRANE

METAL DOOR

MANUFACTURER

MINIMUM

MATERIAL

MAXIMUM

F.SZ.

FT.3

FT.2

GA.

F.O.

FUR.

GALV.

FT.

FURRING

FRAMED OPENING

FEET/FOOT

SQUARE FEET

CUBIC FEET

GALVANIZED

GAUGE

VESTIBULE

WOOD

WITH

WROUGHT IRON

WATER CLOSET

VEST.

W.

W.D.

W.I.

WD.

W.C.

W/

V.W.C.

ROOM

REQUIRED

RESILIENT

RETAINING

ROUGH OPENING

RESILIENT BASE

RAIN WATER LEADER

REFRIGERATOR

REQD.

RESIL.

R.W.L.

RB.

RM.

R.O.

RET.

REFIG.

WIDE, WIDE FLANGE

WINDOW DIMENSION

VINYL WALL COVERING

YARDYD.

M.M.C. MISC. METAL CONTRACTORDSP. DISPENSERAFF ABOVE FINISHED FLOOR GYPSUM SHEATHING

UNDERWRITERS LABORATORY

PERPENDICULAR (TO)PERP.INSUL. INSULATIONEXT. EXTERIOR

CEM. CEMENT

CONC. MASONRY UNIT

CONC. HOUSEKEEPING PAD

C.M.U.

C.O.

COL. COLUMN

CLEAR OPENING

CONT.

CONST.

COND.

CONTR.

C.H.P.

CONTRACTOR

CONSTRUCTION

CONTINUOUS

CONDITION

CONC. CONCRETE

CLEAR

CLOS.

CLR.

CLKG.

CLG. CEILING

CER./C.T. CERAMIC TILE

C.I. CAST IRON

C.I.P. CAST IN PLACE

C.J. CONTROL JOINT

C.G. CORNER GUARD

CLOSET

CHALKINGPAINTEDPTD.LB./# POUND

CABINET

L.C.

L.D.P.

LEAD COATED

LAMINATED DRYWALL PART.

LVR.

L.P.

L.O.W.

LI.WT.

L.G.M.F.

LIMIT OF WORK

LOUVER

LOW POINT

LIGHT WEIGHT

LGTH. LENGTHF.F.

F.H.

FACTORY FINISH

FLAT HEAD

FIN.

F.P.

FL.

F.S.

FLASH.

FLUOR.

FINISH

FLASHING

FLUORESCENT

FIRE PROOFING

FLOOR

FIRE SHIELD

F.H.C. FIRE HOSE CABINET

LIGHT GAGE METAL FRAMINGU.L.

VINYL CLAD

UNIT VENTILATOR

UPPER

VENTILATOR

V.C.

U.P.R.

U.V.

VENT.

U.O.N.

PRESSURE TREATEDP.T.

RADIUS

RISER

QUANTITY

ROOF DRAIN

r.

RAD. ENCL.

R.

QTY.

R.D.

Q.T. QUARRY TILE

RADIATOR ENCLOSURE

UNLESS OTHERWISE NOTED

INV.

INT.

JT.

LAM.

JST.

INVERT

JOINT

JOIST

INTERIOR

LAMINATED

F.C.P.

F.D.C.

EXTIN.

F.C.

F.E.

F.D.

F.E.C.

FB. FLAT BAR

FIBER CEMENT

EXTINGUISHER

FIRE DEPT. CONNECTION

FIBER CEMENT PANEL

FIRE EXTINGUISHER

FIRE EXTINGUISHER

FLOOR DRAIN

PLATE

PLASTER

PLASTIC LAMINATE

PLYWOOD

POLISHED

PAIR

PANEL

PLUMBING

PL.

PLAS.

P.L.

PLYWD.

POL.

PR.

PNL.

PLUMB.

BLDG. BUILDING

BLK. BLOCK

BM. BEAM

BOT. BOTTOM

BLKG. BLOCKING

BSMT. BASEMENT

CAB. CABINET

C.B. CORNER BOARD

ANCH.

@ AT

BD. BOARD

ALU. ALUMINUM

APPROX. APPROXIMATELY

BKT. BRACKET

ANCHOR

ALUM. ALUMINUM

STANDARDSTD.ON CENTERO.C.HT. HEIGHT

ELEV. ELEVATION (FACADE)

I.D.

IN.

HVAC

& AIR CONDITIONING

INSIDE DIAMETER

INCH, INCHES

HEATING, VENTILATING

ELEV.

E.T.R.

EQ.

E.S.

EXH.

ELEVATOR

EQUAL

EACH SIDE

EXHAUST

EXISTING TO REMAIN

IN.3

INFIL.

INCAN.

INFILTRATION

CUBIC INCHES

INCANDESCENTEXP. JT.

EXP.

EXPANSION JOINT

EXPOSED

IN.2 SQUARE INCHES

EXIST. EXITING

STEEL

STRUCTURAL

SUSPENDEDSUSP.

STL.

STRUCT.

OPERATE

OPENING

OUTSIDE DIAMETER

OPPOSITE HAND

OVERHEAD

O.D.

OPER.

O.H.

OVHD.

OPNG.

PARTITION

PERIMETERPERIM.

PARTN.

OZ. OUNCE(S)

H.C.

HD

H.M.

H.C.P.

HDWR.

H.C.P.

HR.

HORIZ.

HANDICAP

HANDICAP

HIGH DENSITY

HARDWARE

HORIZONTAL

HOLLOW METAL

HOUR

HANDICAP

EA.

ED.

E.J.

D.W.

DWG.

ELEC.

EL.

DRY WALL

EXPANSION JOINT

EACH

EDUCATION

ELECTRICAL

ELEVATION (GRADE)

DRAWING

SIMILAR

STORAGE

SPECIFICATIONS

SQUARE

SLIDING

STAINLESS STEEL

SIM.

SQ.

STOR.

SPEC.

SLID.

S.S.

S.T.

NOMINAL

NUMBER

NATURAL

NONCORROSIVE

NOT IN CONTRACT

OVERALL

N.C.

N.I.C.

NO./#

NOM.

NAT.

O.A.

STRUCTURAL TUBE

Z ZEE (STRUCTURAL SHAPE)

ACOUST. ACOUSTICAL

A.D. AREA DRAIN

ADJ. ADJUSTABLE

GYP.

G.S.U.

GYPSUM

GLAZED STRUCTURAL UNIT

G.W.B. GYPSUM WALLBOARD

DN.

DO. DITTO (REPEAT)

DOWN

D.O. DOOR OPENING

SHELVES

SHEET

SH.

SHT.

S.I.G.S.

METAL THRESHOLD

MOUNTED

M.T.

MTD.

MTL. METAL SILICON IMPREGNATED

WEIGHTWT.

W.W.M.

X INDICATES TIMES OR BY

WELDED WIRE MESH

TELEPHONE

TERRA COTTA

TACK BOARD

THRESHOLD

THICKNESS

TONGUE & GROOVE

TERRAZZO

TOP OF CONCRETE

TOP OF STEEL

TOP OF WALL

TOP OF BLOCKING

THRESH.

T.O.S.

T.W.

TYP.

TWR.

T.

TBLE.

TEL.

T.C.

T.B.

T&G

TLT.

THK.

TERR.

T.O.C.

T.O.B.

TYPICAL

TOWER

TABLE

TREADS

TOILET

CTOP COUNTERTOP

BKSP . BACKSPALSH

EDSP. ENDSPLASH

WATERPROOFINGW.P.

UNDERCUTU.C.

CG CORNER GUARD

F.D.V. FIRE DEPT. VALVE

F.D.V.C. FIRE DEPT. VALVE CABINET

SCUPPERSC.

FTR FIN-TUBED RADIATOR

(VISUAL DISPLAY BOARD)

WINDOW OPENINGW.O.

SELF ADHERED MEMBRANESAM

POLYVINYL CHLORIDEPVC

HB HOSE BIBB

UNIT VENTILATOR GRILLEUVG

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

1

Page 4: HALIFAX ELEMENTARY SCHOOL

EXISTING BRICK VENEER

EXISTING LOUVER TO REMAIN

16

LF LF

3

AA

LFLF

B

D

2

1

2

S1

UVG UVG UVG

DB LF

LS

LF

9

Q Q Q Q Q Q Q Q Q

2 14 1

21

V V V V V

X X X XX X

EXISTING PILASTER TRIMWORK TO REMAIN

29

32

TYP

33

AA

REMOVE EXISTING VINYL SIDING

20

14

LF1

2

LF

1

2

A

24

EH

CONDUIT

31

31

R

EXISTING STUCCO

FROSTED GLASS

HALIFAX ELEMENTARY SCHOOL

464

LIBRARY, NIC

19

LF LF

1

JB

LF

HBUVG

JBFDL

C H

2

AA AA AALF

DB

1

14 25 24 23

27

22 14

26 1

REMOVE PANEL

2

103

U

W

14

20

ELECTRICAL CONDUIT

FDC14

EB

PIPE SUPPORT 14

14

PIPE TO BE REMOVED

214

6

29

29

EXISTING PILASTER TRIMWORK TO REMAIN

EXISTING PILASTER / PEDIMENT TRIMWORK TO REMAIN

33

1

EXISTING WOOD TRIMWORK & SILL TO REMAIN AT WINDOW TYPES AA, R, W & V -TYPICAL

V VV

LF

LS

EXISTING WOOD TRIMWORK & SILL TO REMAIN AT WINDOW TYPES AA, R, W & V -TYPICAL

W

EXISTING STUCCO4

VH

EXISTING WOOD TRIMWORK & SILL TO REMAIN AT WINDOW TYPES AA, R, W & V -TYPICAL

3

3

6

3

3

EXISTING WOOD PANELS & TRIM BOARDS TO REMAIN -SCRAPE AND PAINT

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

WING A

WING B

WING C

KEY PLAN KEY PLAN

1/8" = 1'-0"

1/2

3/2

018

11:1

3:2

0 A

M

AD-201

EXTERIORELEVATIONS -DEMOLITION

1614.03

12/13/17

jas

JD

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/8" = 1'-0"D1

WING A - NORTH - DEMO

1/8" = 1'-0"A1

WING A - E - DEMO

1/8" = 1'-0"C1

WING B - NORTH - DEMO

1/8" = 1'-0"B6

WING B - L - DEMO 1/8" = 1'-0"

B5WING B - K - DEMO

1/8" = 1'-0"B1

WING A - A - DEMO 1/8" = 1'-0"

B2WING A - B - DEMO

1/8" = 1'-0"A2

WING A - F - DEMO

1/8" = 1'-0"B3

WING A- C - DEMO 1/8" = 1'-0"

B4WING A - D - DEMO

1/8" = 1'-0"A3

WING B - I - DEMO 1/8" = 1'-0"

A4WING B - J - DEMO

D1

B1 B2

B3 B4

B5B6

C1

A1A2

A3

A4

1992 ADDITION

1964ADDITION

1992 ADDITION

1958 BUILDING

1992 ADDITION

COURTYARD

NOTE: REFER TO SHEET AD-204 FOR TYPICAL DEMOLITION ELEVATION KEY NOTES.

FPDR

B3

E E

1975 TOWN

LIBRARY (NIC)

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 5: HALIFAX ELEMENTARY SCHOOL

C C A

5

S1

10

7

1

8

2

9

LFLF

17

1

1LF

2 2

2

1LF

4

C C

33

31

EB

F F F F F

14

1

14 9

13

2

12

UVG UVG UVG UVGUVG

2 13

LF

1

19

3

30

32 TYP.

EXISTING DOOR, FRAME & TRANSOM TO REMAIN

EB

12

UVG UVG UVG UVG

2 218

LF

1

14914

LFF F F F

G

UVG

32 TYP.

EB

LIBRARY N.I.C

11592 18 14

LF

FIRE DEPT. CONNECTION TO REMAIN

2

FP

EXISTING BRICK WALL

T

EXISTING LOUVER TO REMAIN

21116

1

2

LF

9

LF

3

LF

1

V V V

U

UVG

2

12

EXISTING LIBRARY WINDOW TO REMAIN

EXISTING LIBRARY TRIMBOARDS TO REMAIN

REMOVE SIDING & TRIM BOARDS - TYPICAL

2

3

REMOVE AND RESET EXISTING KNOX, BOX, BELL & FIRE ALARM ANUNCIATOR

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

WING A

WING B

WING C

KEY PLAN KEY PLAN

1/8" = 1'-0"

1/2

3/2

018

11:1

3:2

8 A

M

AD-202

EXTERIORELEVATIONS -DEMOLITION

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/8" = 1'-0"D1

WING A - EAST - DEMO

1/8" = 1'-0"C1

WING C - EAST - DEMO

1/8" = 1'-0"B2

WING B- WEST - DEMO 3 1/8" = 1'-0"

B1WING B - WEST - DEMO - 2

1/8" = 1'-0"D2

WING A - SOUTH - DEMO

1/8" = 1'-0"A1

WING B - A - DEMO 1/8" = 1'-0"

A6WING B - C - DEMO

1/8" = 1'-0"A4

WING B - E - DEMO 1/8" = 1'-0"

A5WING B - F - DEMO

1/8" = 1'-0"A3

WING B - D - DEMO 1/8" = 1'-0"

A2WING B - B- DEMO

A4

A2

A1

A3

A5A6

B1

B2

D1

C1

D2

C1

1992 ADDITION

1964ADDITION

1992 ADDITION

1958 BUILDING

1992 ADDITION

COURTYARD

NOTE: REFER TO SHEET AD-204 FOR TYPICAL DEMOLITION ELEVATION KEY NOTES.

1975 TOWN

LIBRARY (NIC)

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 6: HALIFAX ELEMENTARY SCHOOL

I I

I

I I

I

IL

I I

L

II

M

I

I II

I

15 15 15 15

12 12 12 12

2 2 2 2

UVG UVG

UVG UVG UVG UVG UVG

UVG UVG UVG

UVG

UVGUVGUVGUVG UVG

UVG UVG

8

2

12 12

2 2

2

12 12 12 12 12 12

2 11 1 2 2 2

8

LF

9 28 12 9

14

N

30 30 30 30

EXISTING PVC BOARD TO REMAIN AT DORMER

EXISTING ROOFING/FLASHING TO REMAIN - TYPICAL

2

LF1

30

30

2

LF1

14 14

TOOL RACK

14S

D D D

TOOL RACK

14

EXISTING DOOR & FRAME TO REMAIN

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

WING A

WING B

WING C

KEY PLAN KEY PLAN

1/8" = 1'-0"

1/2

3/2

018

11:1

3:3

5 A

M

AD-203

EXTERIORELEVATIONS -DEMOLITION

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/8" = 1'-0"D1

WING C - SOUTH - DEMO

1/8" = 1'-0"C1

WING C - A - DEMO 1/8" = 1'-0"

C2WING C - B - DEMO

1/8" = 1'-0"C3

WING C - C - DEMO 1/8" = 1'-0"

C4WING C - D - DEMO

1/8" = 1'-0"C5

WING C - E - DEMO 1/8" = 1'-0"

C6WING C - F - DEMO

1/8" = 1'-0"B1

WING C - G -DEMO 1/8" = 1'-0"

B2WING C - H - DEMO

1/8" = 1'-0"B3

WING C - I - DEMO 1/8" = 1'-0"

B4WING C - J - DEMO

1/8" = 1'-0"A1

WING C - NORTH - DEMO 2 1/8" = 1'-0"

A2WING A - SOUTH - DEMO 2

A1

A2

B3C5

B4

A1

A2

C2B1 C6 C1C4

C3B2D1

NOTE:KEY-INS ARE NOT ALL SHOWN FOR CLARITY. SOUTH ELEVATION IS SYMETRICAL

1992 ADDITION

1964ADDITION

1992 ADDITION

1958 BUILDING

1992 ADDITION

COURTYARD

NOTE: REFER TO SHEET AD-204 FOR TYPICAL DEMOLITION ELEVATION KEY NOTES.

1975 TOWN

LIBRARY (NIC)

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 7: HALIFAX ELEMENTARY SCHOOL

F REMOVE EXISTING DOOR & SCREEN DOOR

REMOVE SIDING AND REPLACE AT RETURN WALLS - TYPICALEXISTING ROOFING AND FLASHING TO REMAIN - TYPICAL

LF1

232

4

92

V

H G H G H

VH

32 TYP.

30

FFFFH

ELECTRICAL DISCONNECT SWITCH

14

EXISTING DOOR -REMOVE AND REPLACE TRIM BOARDS

2

Z

UVG UVG UVG UVG

LF

1 2

LF

1FA H/SFA H/S 232 TYP.

2

UVG

2

LF

114

FA HS

2 9

LF

1 14

FA HS

8

BELL

F F F F

UVGUVGUVG

Y

EXISTING DOOR & FRAME TO REMAIN

32 TYP.

D D D DDD

S S

2

P P

O

2

2 2 22 EXISTING ROOFING AND FLASHING TO REMAIN - TYPICAL 2

UVG UVG UVG UVG

2 9

STONE VENEER TO REMAIN (TYP)

142 2 2

LF

1

EXISTING LOUVER

9FP DR

K K

30 30 30 30

DEMOLITION GENERAL NOTES

1. REMOVE ALL WOOD AND VINYL SIDING, WOOD TRIM BOARDS, EXTERIOR WINDOW CASING, WATER TABLE, WINDOW SILLS, WINDOW APRONS, BUILDING PAPER UNLESS MARKED TO REMAIN ON THE DRAWINGS, EXISTING GUTTERS, FASCIA, RAKE BOARDS AND METAL SOFFIT FACING TO REMAIN.

2. REMOVE ALL EXTERIOR WINDOW SYSTEMS EXCEPT AT LOCATIONS MARKED TO REMAIN ON THE DRAWINGS.

3. REMOVE ALL EXTERIOR DOOR SYSTEMS, TRANSOM LITES AND SIDE LITES EXCEPT AT LOCATIONS MARKED TO REMAIN ON THE DRAWINGS.

4. REMOVE ALL EXTERIOR DOOR NUMBER SIGNAGE.

5. CUT WINDOW NAILING FINS AT VINYL WINDOWS.

6. CONTRACTOR TO MODIFY WOOD BLOCKING AT EXISTING ROUGH OPENINGS FOR INSTALLATION OF NEW WINDOW AND STOREFRONT FRAMES.

7. REMOVE EXISTING FABRIC SHADES INCLUDING CORDS, MOUNTING BRACKETS, & ALL FASTENERS, TYPICAL.

8. REMOVE AND REPLACE 1X WOOD INTERIOR WINDOW TRIM AT LOCATIONS WHERE TRIM INTERFERES WITH PLACEMENT OF NEW WINDOW SYSTEM.

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

WING A

WING B

WING C

KEY PLAN KEY PLAN

As indicated

1/2

3/2

018

11:1

3:4

2 A

M

AD-204

EXTERIORELEVATIONS -DEMOLITION

1614.03

12/13/17

jas

JD

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/8" = 1'-0"B1

INTERIOR COURTYARD - VIEW LOOKING NORTH - DEMO

1/8" = 1'-0"A2

INTERIOR COURTYARD - VIEW LOOKING WEST - DEMO

1/8" = 1'-0"A1

INTERIOR COURTYARD - VIEW LOOKING EAST - DEMO

1/8" = 1'-0"C1

INTERIOR COURTYARD - VIEW LOOKING SOUTH - DEMO

A1

A2

C1

A1 A2

B1

1/8" = 1'-0"D1

WING B - SOUTH - DEMO

D1

1992 ADDITION

1964ADDITION

1992 ADDITION

1958 BUILDING

1992 ADDITION

COURTYARD

DEMOLITION KEY NOTESNUMBER DESCRIPTION

1 REMOVE LIGHT FIXTURE AND RESET AFTER NEW WORK IS COMPLETED.

2 REMOVE RAINWATER LEADER & RESET AFTER NEW WORK IS COMPLETED. REPLACE ANY DAMAGED KLEETS.

3 REMOVE MDO PLYWOOD, TRIM WORK AND ROTTED PORTIONS OF WOOD STUD BACKUP WALL.

4 REMOVE VENT HOOD AND RESET AFTER NEW WORK IS COMPLETED. PROVIDE NEW PVC TRIMBOARD AROUNDVENT HOOD.

5 REMOVE AND REPLACE OVERHEAD DOOR.

6 REMOVE AUTOMATIC DOOR BUTTOM AT ACCESSIBLE ENTRANCE AND RESET AFTER NEW WORK IS COMPLETED.

7 REMOVE WOOD TRIM BOARDS AND HEAD/JAMB BOARDS AT OVERHEAD DOOR OPENING AND REPLACE WITH PVCBOARDS.

8 REMOVE GONG (BELL) AND RESET AFTER NEW WORK IS COMPLETED.

9 REMOVE ELECTRICAL OUTLET AND RESET AFTER NEW WORK IS COMPLETED.

10 REMOVE FUEL OIL VENT PIPE AND RESET AFTER NEW WORK IS COMPLETED.

11 REMOVE EXISTING WOOD TRIM BETWEEN TOP OF WINDOW AND BOTTOM OF SOFFIT AND REPLACE WITH PVCBOARD.

12 REMOVE UNIT VENTILATOR GRILLES, SCRAPE, PAINT AND RESET IN BEAD OF SEALANT AT PERIMETER OF THEGRILLS.

13 REMOVE PANELIZED WOOD TRIM BOARDS AND PANELS, AND REPLACE WITH NEW TRIM BOARDS AND PANELS.PANEL SIZES TO MATCH EXISTING.

14 REMOVE DEVICE AND RESET AFTER NEW WORK IS COMPLETED.

15 REMOVE EXISTING LOUVER AND INFILL OPENING WITH SIDING, AIR/VAPOR BARRIER AND 5/8" EXTERIORSHEATHING. PROVIDE INSULATION IN THE STUD CAVITY.

16 REMOVE WOOD HEADER ABOVE DOOR/BELOW TRANSOM FOR INSTALLATION OF NEW STOREFRONT FRAME.

17 REMOVE WOOD HEADER ABOVE DOOR/BELOW TRANSOM AND WOOD POST BETWEEN DOOR AND SIDE LITE ATBOTH SIDES OF DOOR FOR INSTALLATION OF NEW STOREFRONT FRAME.

18 RELOCATE CABLE RUNNING EXPOSED ON SIDE OF BUILDING TO INTERIOR.

19 SCRAPE, PATCH & REPAIR STUCCO. PRIME AND PAINT.

20 REMOVE ELECTRICAL CONDUCT AND JUNCTION BOX AND RESET AFTER NEW WORK IS COMPLETED.

21 REMOVE LOUD SPEAKER AND RESET AFTER NEW WORK IS COMPLETED.

22 REMOVE ELECTRICAL JUNCTION BOX AND WIRING.

23 REMOVE WATER SPIGOTS AND RESET AFTER WORK IS COMPLETED.

24 REMOVE DRYER VENT AT WINDOW PANE.

25 REMOVE ONE SECTION OF FENCE TO INSTALL SIDING AND RESET AFTER WORK IS COMPLETED.

26 CALL BUTTON TO BE RELOCATED TO NEW DOOR FRAMING SYSTEM.

27 REMOVE PROPERTY ADDRESS NUMBERS AND HALIFAX ELEMENTARY SCHOOL LETTER SIGNAGE AND RESET INSAME LOCATION AFTER SIDING WORK IS COMPLETED.

28 REMOVE EXISTING HVAC CONDENSING UNIT, SUPPORT BRACKETS, ELECTRICAL DISCONNECT SWITCH ANDPIPING AND RESET IN SAME LOCATION AFTER SIDING WORK IS COMPLETED.

29 REMOVE PAINT, PATCH & REPAIR DAMAGED WOOD, PRIME AND PAINT.

30 REMOVE DOOR AND HARDWARE - FRAME TO REMAIN.

31 REMOVE EXISTING VINYL SIDING, INSULATION, OLD WOOD SIDING AND TAR PAPER DOWN TO WOOD SHEATHING.

32 REMOVE EXISTING PLYWOOD PANELS & STOPS & TRIMBOARDS.

33 REMOVE DOORS, FRAMES, WINDOWS, CERAMIC TILE, DRYWALL & WOOD CASING.

J J J J

1975 TOWN

LIBRARY (NIC)

EB

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 8: HALIFAX ELEMENTARY SCHOOL

C1

AD-511

B1

AD-511

A1

AD-511

B2

AD-511

A2

AD-511

C2

AD-511

C2

AD-511

B2

AD-511

A2

AD-511

C4

AD-511

SIM

B4

AD-511

A4

AD-511

C4

AD-511

SIM

B4

AD-511

A4

AD-511

D2

AD-512

C2

AD-512

B2

AD-512

A2

AD-512

C4

AD-513

B4

AD-513

A4

AD-513

B3

AD-513

D5

AD-512

C5

AD-512

A5

AD-512

B5

AD-512

A5

AD-512

D5

AD-512

C5

AD-512

D2

AD-511

C4

AD-511

SIM

B4

AD-511

B5

AD-511

A5

AD-511

A3

AD-513

@ DOOR

I I I

AT CANOPY

A3

AD-513

D1

AD-511

@ DOOR

A5

AD-511

B5

AD-511

@ DOOR

F.F.

C4

AD-511

SIM

B4

AD-511

B5

AD-511

A5

AD-511

A3

AD-513 SIM

REMOVE WOOD HEADER

EXISTING POST TYP

C4

AD-511

SIM

B4

AD-511

B5

AD-511

A5

AD-511

C4

AD-511

SIM

A4

AD-511

C3

AD-512

B4

AD-511

EXISTING STRUCTURAL POSTS, TYPICAL

C2

AD-513

SIM

B2

AD-513

SIM

A2

AD-513

A3

AD-512

B4

AD-511

A4

AD-511

C3

AD-512

C2

AD-513

SIM

B2

AD-513

SIM

A2

AD-513

C2

AD-513

SIM

B2

AD-513

SIM

A2

AD-513

C2

AD-513

SIM

B2

AD-513

SIM

A3

AD-512

B4

AD-511

A4

AD-511

A3

AD-512

A4

AD-511

B4

AD-511

D3

AD-512

A3

AD-513

EXISTING POST

REMOVE WOOD HEADER FOR NEW STOREFRONT

C4

AD-512

B4

AD-512

SIM

A4

AD-512

B1

AD-513

A1

AD-513

C4

AD-511

SIM

B4

AD-511

A4

AD-511

C3

AD-512

A4

AD-511

B4

AD-511

A3

AD-512

B3

AD-512

C2

AD-513

SIM

B2

AD-513

SIM

A2

AD-513

C2

AD-513

SIM

B2

AD-513

SIM

A2

AD-513

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

1/4" = 1'-0"

1/2

3/2

018

11:1

3:4

6 A

M

AD-501

WINDOW TYPES -DEMOLITION

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/4" = 1'-0"A

GYMNASIUM 1/4" = 1'-0"

C.GYMNASIUM

1/4" = 1'-0"B

GYM OFFICE 1/4" = 1'-0"

DGYM TOILET

1/4" = 1'-0"E

GYMNASIUM ENTRY 1/4" = 1'-0"

FCLASSROOM

1/4" = 1'-0"G

COURTYARD

1/4" = 1'-0"H

COURTYARD WINDOW 1/4" = 1'-0"

ICLASSROOM - WING C

1/4" = 1'-0"J

KINDERGARTEN 1/4" = 1'-0"

KADMINISTRATION

1/4" = 1'-0"L

MEDIA CENTER 1/4" = 1'-0"

M.MEDIA CENTER

1/4" = 1'-0"AA

KITCHEN / TOILET

1/4" = 1'-0"P

COURTYARD UNIT & WING C

1/4" = 1'-0"Z

INTERIOR COURTYARD 1/4" = 1'-0"

VCAFETERIA

1/4" = 1'-0"R

STORAGE ROOM 1/4" = 1'-0"

SSTAIR

1/4" = 1'-0"T

GYMNASIUM LOBBY RAMP ENTRANCE 1/4" = 1'-0"

U.KINDERGARTEN

1/4" = 1'-0"Q

ART / MUSIC ROOM

1/4" = 1'-0"X

.ART / MUSIC ROOM

1/4" = 1'-0"N

MEDIA CENTER . 1/4" = 1'-0"

OCOURTYARD - WING C

1/4" = 1'-0"W

WING B -L -WINDOW 1/4" = 1'-0"

YINTERIOR COURTYARD-02

E E

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 9: HALIFAX ELEMENTARY SCHOOL

F.F.

C4

AD-511

SIM

D3

AD-512

F.F.

C4

AD-511

SIM

B4

AD-511

A3

AD-513

D3

AD-512

C1

AD-512

@ LOBBY

EXISTING STRUCTURAL WOOD POSTS & HEADER

F.F.

C1

AD-512

A3

AD-513

B4

AD-512

SIM

D1

AD-512

EXISTING STRUCTURALWOOD POSTS & HEADER

A3

AD-512

D3

AD-512

D3

AD-512

F.F.

B D PO QA B

DOOR TYPES FRAME TYPES

AA D

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

1/4" = 1'-0"

1/2

3/2

018

11:1

3:4

8 A

M

AD-502

DOOR AND FRAMETYPES -

DEMOLITION

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/4" = 1'-0"2

KITCHEN ENTRANCE 1/4" = 1'-0"

3KINDERGARTEN ENTRANCE

1/4" = 1'-0"1

ADMINISTRATION-DOOR

1/4" = 1'-0"S1

GYMNASIUM LOBBY 1/4" = 1'-0"

S2MAIN LOBBY ENTRANCE

1/4" = 1'-0"4

GYMNASIUM ENTRANCE 1/4" = 1'-0"

5MEDIA CENTER

1/4" = 1'-0"6

_CAFETERIA 1/4" = 1'-0"

7GYMNASIUM LOBBY RAMP ENTRANCE-DOOR

DOOR AND FRAME TYPES

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 10: HALIFAX ELEMENTARY SCHOOL

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

3" = 1'-0"

1/2

3/2

018

11:1

3:5

1 A

M

AD-511

WINDOW &STOREFRONT

DETAILS -DEMOLITION

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

0' 2" 4" 8"

3" = 1'-0"

0' 2" 4" 8"

3" = 1'-0"

0' 2" 4" 8"

3" = 1'-0"

0' 2" 4" 8"

3" = 1'-0"

0' 2" 4" 8"

3" = 1'-0"

0' 2" 4" 8"

3" = 1'-0"

3" = 1'-0"A1

WINDOW SILL DETAIL - GYM

3" = 1'-0"B1

WINDOW JAMB DETAIL - GYM

3" = 1'-0"C1

WINDOW HEAD DETAIL - GYM 3" = 1'-0"

C2WINDOW HEAD DETAIL - GYM

3" = 1'-0"A2

WINDOW SILL DETAIL - GYM

3" = 1'-0"B2

WINDOW JAMB DETAIL - GYM

3" = 1'-0"A4

WINDOW SILL DETAIL (FIXED OR AWNING)

3" = 1'-0"B4

WINDOW JAMB DETAIL

3" = 1'-0"C4

WINDOW HEAD DETAIL

3" = 1'-0"A5

WINDOW SILL DETAIL (DOUBLE HUNG)

3" = 1'-0"B5

WINDOW JAMB DETAIL

3" = 1'-0"C5

WINDOW HEAD DETAIL

3" = 1'-0"D1

WINDOW HEAD DETAIL AT KINDERGARTEN 3" = 1'-0"

D2WINDOW HEAD DETAIL @ WING 'C' 1ST FL. CLASS ROOM

EXISTING FLASHING TO REMAIN

EXISTING ACOUSTIC PANEL

EXISTING WOOD CASING TO REMAIN

REMOVE EXISTING SHADE

EXISTING CEILING TO REMAIN

REMOVE EXISTING METAL FLASHING

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD SILL

REMOVE EXISTING SILL FLASHING

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

EXISTING WALL CONSTRUCTION

REMOVE EXISTING WOOD TRIM BOARD

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD SILL

EXISTING WALL CONSTRUCTION

REMOVE EXISTING WOOD TRIM BOARD

EXISTING STEEL LINTELS

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

EXISTING ACOUSTIC PANEL

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

EXISTING ACOUSTIC PANEL

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

EXISTING ACOUSTIC PANEL

EXISTING STEEL LINTELS

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD SILL

REMOVE EXISTING SILL FLASHING

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

EXISTING WOOD STOOL AND APRON TO REMAIN

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

EXISTING WOOD STOOL TO REMAIN

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

EXISTING WOOD CASING TO REMAIN

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

EXISTING WOOD CASING TO REMAIN

REMOVE EXISTING SHADE

EXISTING WALL CONSTRUCTION

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

REMOVE EXISTING METAL FLASHING

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD SILL

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WOOD CASING TO REMAIN

REMOVE EXISTING SHADE

EXISTING CEILING TO REMAIN

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD TRIM BOARD

REMOVE EXISTING WOOD TRIM BOARD

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD SILL

REMOVE EXISTING SILL FLASHING

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

EXISTING WOOD STOOL AND APRON TO REMAIN

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

EXISTING WOOD CASING TO REMAIN

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

REMOVE EXISTING METAL FLASHING

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

EXISTING WOOD CASING TO REMAIN

REMOVE EXISTING SHADE

EXISTING WALL CONSTRUCTION

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 11: HALIFAX ELEMENTARY SCHOOL

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

3" = 1'-0"

1/2

3/2

018

11:1

3:5

5 A

M

AD-512

WINDOW &STOREFRONT

DETAILS -DEMOLITION

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

3" = 1'-0"A2

WINDOW SILL AT GYM - DEMO

3" = 1'-0"B2

WINDOW JAMB AT GYM - DEMO

3" = 1'-0"C2

WINDOW JAMBS AT GYM STL. POST - DEMO

3" = 1'-0"D2

WINDOW HEAD AT GYM - DEMO

3" = 1'-0"A3

WINDOW HEAD - DEMO

3" = 1'-0"B3

WINDOW JAMBS AT STL. POST - DEMO

3" = 1'-0"C3

WINDOW JAMB AT WOOD POST - DEMO 3" = 1'-0"

C1WINDOW SILL @ ENTRANCE - DEMO

3" = 1'-0"D1

WINDOW HEAD @ ENTRANCE - DEMO

3" = 1'-0"A4

WINDOW SILL @ KINDERGARTEN - DEMO

3" = 1'-0"B4

WINDOW JAMB @ KINDERGARTEN - DEMO

3" = 1'-0"C4

WINDOW HEAD @ KINDERGARTEN - DEMO

3" = 1'-0"A5

WINDOW SILL @ COURTYARD - DEMO

3" = 1'-0"B5

WINDOW JAMB @ COURTYARD - DEMO

3" = 1'-0"C5

WINDOW JAMB @ COURTYARD - DEMO

3" = 1'-0"D5

WINDOW HEAD @ COURTYARD - DEMO 3" = 1'-0"

D3TRANSOM AT ENTRANCE - DEMO

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD SILL

REMOVE EXISTING SILL FLASHING

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

EXISTING WOOD STOOL AND APRON TO REMAIN

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP

SEE DETAIL A3/AD-512 FOR SIMILAR NOTES SEE DETAIL B1/AD-512 FOR SIMILAR NOTES

REMOVE EXISTING CLAPBOARD SIDING AND TAR PAPER, TYP

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

EXISTING WALL CONSTRUCTION

EXISTING WOOD CASING TO REMAIN

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

EXISTING STEEL TUBE

REMOVE EXISTING METAL FLASHING AND WOOD BLOCKING.

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

EXISTING WOOD POST

REMOVE EXISTING METAL FLASHING

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

EXISTING WOOD CASING TO REMAIN

EXISTING WOOD CASING TO REMAIN

REMOVE EXISTING DOOR AND DOOR FRAME

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

EXISTING WOOD HEADER

REMOVE EXISTING METAL FLASHING AND WOOD BLOCKING.

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE EXISTING WOOD CASING

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

EXISTING STEEL TUBE COLUMN

REMOVE EXISTING WOOD TRIM BOARD

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

EXISTING WOOD CASING TO REMAIN

EXISTING STEEL BEAM

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

EXISTING WOOD FRAME TO REMAIN

REMOVE EXISTING WOOD TRIM & BLOCKING

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE EXISTING WOOD CASING

SEE DETAIL B1/AD-512 FOR SIMILAR NOTES

EXISTING CEILING TO REMAIN

EXISTING CEILING TO REMAIN

REMOVE EXISTING WOOD PANEL, STOPS &TAR PAPER

EXISTING SHEATHING TO REMAIN

REMOVE EXISTING WOOD SIDING AND TAR PAPER

REMOVE EXISTING WOOD SIDING AND TAR PAPER

REMOVE EXISTING WOOD SIDING, TAR PAPER, METAL FLASHING AND TRIMBOARD

EXISTING SHEATHING TO REMAIN

REMOVE EXISTING WOOD PANEL, STOPS, TAR PAPER, METAL FLASHING BLOCKING AND TRIMBOARD -TYPICAL

REMOVE INTERIOR CASING

EXISTING SHEATHING TO REMAIN

REMOVE EXISTING WOOD PANEL, WOOD PANEL RETURN, STOPS, TAR PAPER, METAL FLASHING BLOCKING AND TRIMBOARD -TYPICAL

REMOVE INTERIOR CASING

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD FRAME

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE EXISTING WOOD SILL, PANEL, STOPS, TAR PAPER, METAL FLASHING, BLOCKING AND TRIMBOARD -TYPICAL

EXISTING WOOD SHEATHING TO REMAIN

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

EXISTING WOOD CASING TO REMAIN

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

REMOVE EXISTING METAL FLASHING

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD SILL

REMOVE EXISTING SILL FLASHING

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

EXISTING WOOD STOOL AND APRON TO REMAIN

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP

EXISTING SHEATHING TO REMAIN

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

EXISTING WOOD CASING TO REMAIN

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

REMOVE EXISTING METAL FLASHING

REMOVE EXISTING WINDOW SYSTEM

REMOVE EXISTING WOOD SILL

REMOVE EXISTING SILL FLASHING

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

REMOVE WOOD STOOL, APRON , BASE AND GYPSUM BOARD -TYPICAL

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP

EXISTING SHEATHING TO REMAIN

REMOVE EXISTING CLAPBOARD SIDING AND TAR PAPER, TYP

REMOVE EXISTING WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE WOOD CASING

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

EXISTING CEILING TO REMAIN

REMOVE EXISTING WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

EXISTING WOOD CASING TO REMAIN

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

REMOVE EXISTING WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

1

1

1

1

Page 12: HALIFAX ELEMENTARY SCHOOL

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

3" = 1'-0"

1/2

3/2

018

11:1

3:5

7 A

M

AD-513

WINDOW DETAILS -DEMOLITION

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

3" = 1'-0"C4

COURTYARD HEAD DETAIL - Demo

3" = 1'-0"A4

COURTYARD SILL DETAIL - DEMO

3" = 1'-0"B4

COURTYARD JAMB DETAIL-DEMO

3" = 1'-0"A3

JAMB POST DETAIL - DEMO

3" = 1'-0"B3

COURTYARD JAMB POST DETAIL - DEMO

3" = 1'-0"A2

WINDOW SILL @ WING B - DEMO

3" = 1'-0"B2

WINDOW JAMB @ WING B - DEMO

3" = 1'-0"C2

WINDOW HEAD @ WING B - DEMO

REMOVE EXISTING DOOR AND DOOR FRAME

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

EXISTING WOOD POST

REMOVE EXISTING METAL FLASHING AND WOOD BLOCKING.

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE EXISTING WOOD CASING

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

EXISTING WOOD POST

REMOVE WOOD TRIM AND WOOD BLOCKING

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE EXISTING WOOD CASING

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE EXISTING WOOD CASING

REMOVE WOOD CLOSURE TRIM AND WOOD BLOCKING

EXISTING WALL CONSTRUCTION

REMOVE WOOD PANEL AND STOP

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP.

REMOVE EXISTING WOOD CASING

EXISTING SHEATHING

EXISTING WALL CONSTRUCTION

REMOVE EXISTING WOOD WINDOW SYSTEM

EXISTING WOOD SILL TO REMAIN

REMOVE EXISTING WOOD TRIM BOARD

EXISTING WALL CONSTRUCTION

REMOVE EXISTING WOOD STOOL AND APRON

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

REMOVE EXISTING WOOD WINDOW SYSTEM

REMOVCE EXISTING WOOD CASING

EXISTING WOOD TRIM BOARD TO REMAIN(INTEGRAL TO FRAME/CASING)

EXISTING WALL CONSTRUCTION

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

REMOVE BALANCING WEIGHTS

REMOVE EXISTING WOOD WINDOW SYSTEM

REMOVE EXISTING WOOD CASING(INTEGRAL TO FRAME/CASING)

EXISTING WOOD TRIM BOARD TO REMAIN

EXISTING WALL CONSTRUCTION

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

REMOVE EXISTING METAL FLASHING

REMOVE EXISTING ALUMINUM CLAD WINDOW SYSTEM

REMOVE EXISTING WOOD SILL

REMOVE WOOD PANEL

SHEATHING TO REMAIN

EXISTING WALL CONSTRUCTION

REMOVE EXISTING WOOD STOOL AND APRON

REMOVE EXISTING SEALANT IN ITS ENTIRETY, LEAVING EXISTING CONSTRUCTION FREE OF ANY RESIDUE, TYP

REMOVE STOP

REMOVE WOOD APRON

REMOVE WOOD BLOCKING

ORIGINAL WINDOW FRAME

REMOVE CLOSURE TRIM

REMOVE WOOD CLAPBOARD SIDING AND AIR BARRIER

REMOVE EXISTING WOOD TRIM BOARD

3" = 1'-0"B1

FIXED WINDOW SILL @ ART/MUSIC - DEMO

REMOVE EXISTING FIXED WOOD WINDOW SYSTEM

EXISTING WOOD SILL TO REMAIN

EXISTING WALL CONSTRUCTION

REMOVE WOOD STOOL AND APRON

REMOVE WOOD PANEL AND STOPS

EXISTING WOOD SHEATHING TO REMAIN

3" = 1'-0"A1

DH WINDOW SILL @ ART/MUSIC - DEMO

REMOVE EXISTING DOUBLE HUNG WOOD WINDOW SYSTEM

EXISTING WOOD SILL TO REMAIN

REMOVE WOOD PANEL AND STOPS

EXISTING WALL CONSTRUCTION

REMOVE WOOD STOOL AND APRON

EXISTING WOOD SHEATHING TO REMAIN

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

1

REMOVE PORTION OF CEILING

1

1

1

1

1

1

1

Page 13: HALIFAX ELEMENTARY SCHOOL

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

3" = 1'-0"

1/2

3/2

018

11:1

3:5

9 A

M

AD-521

DOOR DETAILS -DEMOLITION

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

3" = 1'-0"B5

DOOR JAMB DETAIL - DEMO

3" = 1'-0"A4

THRESHOLD DETAIL

3" = 1'-0"C3

HEAD @ EGRESS DOOR - DEMO

3" = 1'-0"A1

JAMB @ OVERHEAD / EGRESS DOOR - DEMO

3" = 1'-0"B1

JAMB @ OVERHEAD DOOR - DEMO

3" = 1'-0"C1

HEAD @ OVERHEAD DOOR - DEMO

SEE DETAIL B4/AD-521 FOR SIMILAR NOTES

REMOVE EXISTING DOOR

REMOVE EXISTING WOOD TRIM BOARD

EXISTING STEEL LINTELS

EXISTING DOOR FRAME TO REMAIN

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

EXISTING WALL CONSTRUCTION

REMOVE EXISTING METAL FLASHING

EXISTING DOOR FRAME TO REMAIN

REMOVE EXISTING DOOR

REMOVE EXISTING WOOD TRIM BOARD

REMOVE EXISTING OVERHEAD DOOR AND TRACK

REMOVE EXISTING OVERHEAD DOOR AND TRACK

REMOVE EXISTING WOOD TRIM BOARD

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

EXISTING MASONRY BACKUP WALL

EXISTING CONCRETE FOUNDATION WALL

REMOVE EXISTING WOOD TRIM BOARD

REMOVE EXISTING OVERHEAD DOOR AND TRACK

REMOVE EXISTING CLAPBOARD SIDING AND VAPOR BARRIER, TYP

REMOVE EXISTING METAL FLASHING

EXISTING WALL CONSTRUCTION

EXISTING WALL CONSTRUCTION

REMOVE DOOR AND THRESHOLD

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 14: HALIFAX ELEMENTARY SCHOOL

REMOVE AND REINSTALLEXISTING ALUMINUMRAINWATER LEADER ASREQUIRED TO INSTALLNEW WORK

EXISTING ALUMINUMGUTTER WITHHANGER STRAPS TOREMAIN

EXISTING METAL FASCIAOVER EXISTING WOODFASCIA BOARD

EXISTING BRAKE METALWITHCONCEALED FASTENERSAT UNDERSIDE OFEXISTING SOFFIT BOARDAND VENT OPENING TOREMAIN

REMOVE EXISTINGCLAPBOARDS

REMOVE EXISTING WOODTRIM

REMOVE AND REINSTALLEXISTING ALUMINUMRAINWATER LEADER ASREQUIRED TO INSTALLNEW WORK

EXISTING ALUMINUMGUTTER WITHHANGER STRAPS TOREMAIN

EXISTING METAL FASCIAOVER EXISTING WOODFASCIA BOARD

EXISTING BRAKE METALWITHCONCEALED FASTENERSAT UNDERSIDE OFEXISTING SOFFIT BOARDAND VENT OPENING TOREMAIN

REMOVE EXISTINGCLAPBOARDS

REMOVE EXISTING WOODTRIM

REMOVE ANDREINSTALL EXISTINGALUMINUM RAINWATERLEADER, AS REQUIREDTO INSTALL NEW WORK

EXISTING CORNICECONSTRUCTION TOREMAIN - SCRAPE ANDPAINT

EXISTING ALUMINUMGUTTER WITHHANGER STRAPS TOREMAIN

EXISTING WOOD TRIMTO REMAIN

REMOVE EXISTINGSIDING AND BUILDINGFELT

REMOVE AND REINSTALLEXISTING ALUMINUMRAINWATER LEADER ASREQUIRED TO INSTALL NEWWORK

EXISTING ALUMINUM GUTTERWITH HANGER STRAPS TOREMAIN

SLOPE

EXISTING METAL FASCIA OVEREXISTING WOOD FASCIABOARD TO REMAIN

EXISTING BRAKE METAL WITHCONCEALED FASTENERSAT UNDERSIDE OF EXISTINGSOFFIT BOARD TO REMAIN

REMOVE EXISTING WOOD TRIM

REMOVE EXISTING WOODSIDING AND BUILDING FELTDOWN TO SHEATHING

EXISTING METAL RAKEFLASHING TO REMAIN

EXISTING METAL RAKEFLASHING OVER RAKE BOARDTO REMAIN

EXISTING BRAKE METAL ATUNDERSIDE OF EXISTINGSOFFIT BOARD TO REMAIN

EXISTING ALUMINUMGUTTER WITHHANGER STRAPS TOREMAIN

REMOVE EXISTING WOOD TRIM

REMOVE EXISTING SIDING

EXISTING CONSTRUCTION TOREMAIN

EXISTING CONTINUOUS METALRAKE FLASHING TO REMAIN

EXISTING METAL RAKEFLASHING OVER RAKE BOARDTO REMAIN

EXISTING BRAKE METAL ATUNDERSIDE OF EXISTING RAKEBOARD TO REMAIN

REMOVE EXISTING SIDING ANDWEATHER BARRIER

EXISTING CONSTRUCTION TOREMAIN

(AT FLAT ROOF CLASSROOMS & OFFICES FACING COURTYARD)

REMOVE SASH AND WOOD STOP

EXISTING FRAME CASINGS TO REMAIN

EXISTING CORNICE CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO REMAIN

REMOVE GLASS AND EXTERIOR STOPS

REMOVE COVE MOLDINGEXISTING CORNICE

CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO REMAIN

REMOVE EXISTING GLASS AND GLAZING MATERIALS

REMOVE EXISTING STOOL

EXISTING SILL TO REMAIN

REMOVE PANEL AND STOPS

REMOVE EXISTING EXTERIOR STOP

EXISTING STRUCTURE TO REMAIN

REMOVE EXISTING SASH AND WEATHER STRIPPING

REMOVE EXISTING STOOL

EXISTING SILL TO REMAIN

REMOVE PANEL AND STOPS

EXISTING STRUCTURE TO REMAIN

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

3" = 1'-0"

1/2

3/2

018

11:1

4:0

1 A

M

AD-531

MISC DETAILS -DEMOLITION

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

3" = 1'-0"A1

EAVE GUTTER AT SHINGLE ROOF DETAIL 1 - DEMO 3" = 1'-0"

A2EAVE GUTTER AT SHINGLE ROOF DETAIL 2 - DEMO

3" = 1'-0"A3

EAVE GUTTER DETAIL AT FLAT ROOF - DEMO

3" = 1'-0"B3

RAKE DETAIL 1 - DEMO 3" = 1'-0"

B4RAKE DETAIL 2 - DEMO

3" = 1'-0"B2

HEAD DETAIL-WDO TYPE "X" - DEMO 3" = 1'-0"

B1HEAD DETAIL-WDO TYPE "V" - DEMO

3" = 1'-0"D1

SILL DETAIL-WDO TYPE "V" - DEMO 3" = 1'-0"

D2SILL DETAIL-WDO TYPE "X" - DEMO

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 15: HALIFAX ELEMENTARY SCHOOL

EXISTING SHEATHING TO REMAIN

FIN GRADE SEE DWGS

REMOVE EXISTING VINYL & WOOD, SIDING, TRIM, FLASHING, BLOCKING AND AIR/WATER BARRIER DOWN TO EXISTING SHEATHING

EXISTING EXTERIOR WALL CONSTRUCTION TO REMAIN

REMOVE 1/2" MDO PANEL

EXISTING ALUMINIUM FLASH W/DRIP TO BE REMOVED & RESET

EXISTING GRILLE W/INSECT SCREEN TO BE REMOVED AND RESET

METAL STUD HEADER TO REMAIN

REMOVE EXISTING WOOD TRIM

REMOVE EXISTING WINDOW. SEE WINDOW DEMOLITION DETAILS

REMOVE EXISTING TRIM

EXISTING WOOD BLOCKING TO REMAIN

EXISTING STEEL FRAMING TO REMAIN

EXISTING PLYWOOD SHEATHING TO REMAIN

REMOVE SEALANT

REMOVE EXISTING VINYL & WOOD, SIDING, TRIM, FLASHING, BLOCKING AND AIR/WATER BARRIER DOWN TO EXISTING SHEATHING

EXISTING BRICK TO REMAIN

EXISTING WALL CONSTRUCTION TO REMAIN

REMOVE EXISTING VINYL & WOOD, SIDING, TRIM, FLASHING, BLOCKING AND AIR/WATER BARRIER DOWN TO EXISTING SHEATHING

EXISTING WALL CONSTRUCTION TO REMAIN

EXISTING EXTERIOR WALL CONSTRUCTION TO REMAIN

REMOVE EXISTING DOOR AND FRAME. SEE DOOR DEMOLITION DETAILS

REMOVE EXISTING WOOD TRIM, MOLDINGS AND PLYWOOD PANELS DOWN TO EXISTING SHEATHING

REMOVE EXISTING SHEATHING PANEL TO REMAIN, REPAIR / REPLACE DAMAGED OR ROTTED PORTIONS

REMOVE EXISTING WOOD TRIM, MOLDINGS AND PLYWOOD PANELS DOWN TO EXISTING SHEATHING

REMOVE EXISTING WOOD PILASTER AND TRIM DOWN TO EXISTING SHEATHING

REMOVE EXISTING SIDING, TRIM, FLASHING, BLOCKING AND AIR/WATER BARRIER DOWN TO EXISTING SHEATHING

EXISTING SHEATHING AND WALL CONSTRUCTION TO REMAIN

EXISTING MDO SOFFIT TO REMAIN

REMOVE SIDING

REMOVE EXISTING SIDING, TRIM, FLASHING, BLOCKING AND AIR/WATER BARRIER DOWN TO EXISTING SHEATHING

EXISTING SHEATHING AND WALL CONSTRUCTION TO REMAIN

REMOVE CORNER BOARDS

T.O. FIN GRADE

REMOVE EXISTING VINYL & WOOD, SIDING, TRIM, FLASHING, BLOCKING AND AIR/WATER BARRIER DOWN TO EXISTING SHEATHING

REMOVE MDO PANELS

OUTSIDE F.O. BLDG

REMOVE MDO PANELS

± 81.6'MAIN LEVEL

OUTSIDE F.O. BLDG

REMOVE EXISTING VINYL & WOOD, SIDING, TRIM, FLASHING, BLOCKING AND AIR/WATER BARRIER DOWN TO EXISTING SHEATHING

STEEL TUBE

NAILER

REMOVE 5/4" CORNER BOARDS6

"

6"

REMOVE 5# FELT

REMOVE EPDM COUNTER FLASHEXTEND 4" WALL 16" MIN

REMOVE TERMITE SHIELD

NOMINAL 6" THK. FULLY MORTARED FIELDSTONE WALL

REMOVE BACKER ROD SEALANT

2" AIR SPACE

EPDM COUNTER FLASH CONTINUOS FROM ABOVE

WALL FLASH W/ DRIP

GROUT SOLID FOR 10% SLOPE

WEEP HOLES

CONCRETE FOUNDATION AND SLAB

SLOPE

METAL STUD HEADER

CLAPBOARD

REMOVE PRE FIN ALUMINUM Z FLASH

REMOVE 5/4" WD TRIM TYP. ALL 4 SIDES OF LOUVER

REMOVE GRILL AND STORE FOR REINSTALLATION

PRE FINISH ALUM FLASH W / DRIP EXTEND INTO WALL BEYOND LOUVER

TY

P C

LA

P.B

D

EX

TE

NS

ION

5"

UNIT VENTILATOR

SHT. MTL. BOOT SLOPE AS SHOWN

REMOVE5/4" CORNER BOARDS

6"6

"

REMOVE 3/4" X 3/4" INSIDE CORNER TYPICAL @ INSIDE CORNERS

STONE VENEER WALL BELOW

REMOVE 5/4" CORNER BD. BELOW

11"

REMOVE WOOD TRIM. SEE EXTERIOR ELEVATIONS FOR LOCATIONS

WOOD BLOCK

STEEL TUBE

MATCH EXISTING

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

As indicated

1/2

3/2

018

11:1

4:0

4 A

M

AD-541

WALL DETAILS -DEMOLITION

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

3" = 1'-0"D3

MDO PANEL @ EXTERIOR CLAPBOARD WALL - DEMO

3" = 1'-0"B2

UNIT VENTILATOR GRILLE AT PANEL - DEMO

1 1/2" = 1'-0"C3

CORNERBOARD @ MASONRY TO CLAPBOARD CORNER @ GYM -DEMO

1 1/2" = 1'-0"C4

CORNERBOARD @ CLAPBOARD TO CLAPBOARD CORNER @ GYM -DEMO

1 1/2" = 1'-0"A1

PANELS @ GYM ENTRY - DEMO

3" = 1'-0"B3

SOFFIT CONDITION @ WING C CLASSROOM - DEMO

1 1/2" = 1'-0"B1

OUTSIDE CORNER @ LOBBY ENTRY - DEMO

3" = 1'-0"A4

SILL TRIM @ EXTERIOR GYMNASIUM WALL - DEMO 1/4" = 1'-0"

A2PANEL LAYOUT @ ENTRY TO LOBBY A106 - DEMO

1/4" = 1'-0"A3

PANEL LAYOUT @ MAIN LOBBY B154 - DEMO

3" = 1'-0"B4

SILL TRIM @ EXTERIOR CLAPBOARD WALL - DEMO

1 1/2" = 1'-0"C1

CLAPBOARD TO CLAPBOARD CORNER BOARD - DEMO

3" = 1'-0"D2

FIELDSTONE VENEER - DEMO

3" = 1'-0"C2

UNIT VENTILLATOR GRILLE - DEMO

1 1/2" = 1'-0"D1

CLAPBOARD TO SHINGLES - DEMO 3" = 1'-0"

D4VERTICAL WD TRIM @ MDO. PANEL WALL - DEMO

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

1

Page 16: HALIFAX ELEMENTARY SCHOOL

UP UP

UP

UP

DN

DN

UP

UP

UP

UP

DN

DNDN

DN

UP

WING C

WING A

WING C

WING A

WIN

G A

WIN

G B

WIN

G A

WIN

G B

DN

NO WORK AT TOWN LIBRARY

134

5

5

1111

1

1

11

11

11

1

1

1

11

1

2EX. CR

EX. CR

NEW CR

NOTE: BASEMENT BELOW KITCHEN

NEW CR

11

1 1

NEW CR

NEW CR

139

EX. CR

NEW CR

NEW CR

COURTYARD

FROSTED GLASS AT TOILET ROOMS

WING C

WING A

FIXED(FROSTED GLASS)

OPERABLE WINDOWS

NEW CR

NEW CR

WING C

WING A

A133

REFER TO DOOR #133A ON DOOR SCHEDULE NOTES FOR SCREEN DOOR SPECIFICATION

108 107

106

105

104

103

100 101

102

131

130129128127

126

124123122121117 118

119 120

116115

114

113

138

112

109

132

135 136

GYMNASIUM

A103

LOBBY

A106

CORRIDOR

A125

KITCHEN

B109

CAFETERIA

B157

VESTIBULE

B159

LOBBY

B154

KINDERGARTEN

B155

KINDERGARTEN

B138

KINDERGARTEN

B135

KINDERGARTEN

B136

KINDERGARTEN

B137

ADMIN

B133

STAIRWAY

C136

CLASSROOM

C110

CLASSROOM

C111CLASSROOM

C114

SPEECH

C115

MEDIA

C118

Room

C119

OFFICE

C120

STORAGE

C121

CLASSROOM

C125CLASSROOM

C128

CLASSROOM

C130

CORRIDOR

B139

CLASSROOM

A115

CLASSROOM

A116

CLASSROOM

A117

CLASSROOM

A119

CLASSROOM

A120

GIRLS

A121

JANITOR

A122BOYS

A123

JANITOROFFICE

A126

MENS

A127 WOMENS

A128

WOMENS

A129

CLASSROOM

C101

CLASSROOM

C102

CLASSROOM

C104

CLASSROOM

C105

CORRIDOR

C106

137

PLANNING

B100

TEACHERDINING

B101

CORRIDOR

C119

CLASSROOM

B114

CLASSROOM

B115

CLASSROOM

B117

CLASSROOM

B118

REMEDIAL

C137

CLASSROOM

B119

CLASSROOM

B120

CLASSROOM

B121

OFFICE

B127

CONFERENCE

B124

STORAGE

C131

HEALTH

B128

CLOSET

B129 OFFICE

B130

125

CORRIDOR

A124

PLATFORM

ARTMUSIC CAFETERIA

ST.

ST.

ST.

DISH.DISH. OF.TOIL.

SHSHSHSHSH

SH

SH

SH

SH

SH

SH

SH SH SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SH

SHSH SH

SH

SH

SH

SH

SH

SH

SH

SH SH SH SH

SH SH

TOIL.

3

3

3

TOIL.

SH SH SH SH

PROVIDE BLACKOUT SHADES AT LARGE WINDOWS (HIGH)

3

SH SH SH SH

SH SH

SH SH SH SH SH

3

PROVIDE PVC PANEL AND TRIM BOARDS AT ALCOVE SIDE WALLS

PROVIDE FC SIDING AND PVC TRIM BOARDS AT ALCOVE SIDE WALLS - TYPICAL

SH

3

GYMOFFICE

ELECTRICALCLOSET

3

2

1

1

6

REGRADE80 SF

2

5

5 5

5

5

3

73'-7 9/16"

NOTE: BASEMENT STORAGE AREA BELOW GYM STAGE

SH

FIXED(FROSTED GLASS)

TOIL.

3

AWNING WINDOW AWNING WINDOW

3

TOILET

TOILET

3

5

TOWN LIBRARY(NIC)

PROVIDE BLACKOUT SHADES AT MEDIA

WINDOWS

7 7

77

7

7

7 7

77

7

7

CLASSROOM

C204CLASSROOM

C205

JAN

C202

TOILET

C201

STAIR

C106

ELEV.

A136

CORRIDOR

C214

STO.

C225

OPEN TO BELOW

CLASSROOM

C206

BOYSROOM

C211 CONFER.ROOM

C212

CONFER.ROOM

C215

GIRLSROOM

C216

TOILET

C226

CLASSROOM

C218

CLASSROOM

C219

CLASSROOM

C222

CLASSROOM

C223

SH SHSHSHSHSHSHSH SH

RAMP

1

110

111

GARAGE

A001

OVERHEAD DOOR

1. REPLACE EXISTING DOOR AND HARDWARE - EXISTING NARROW FRAMES TO REMAIN - PAINT FRAMES

FLOOR PLAN KEY NOTES

2. REMOVE EXISTING CERAMIC TILE, WOOD, SILL, WOOD CASING, AND GYPSUM BOARD. PROVIDE INTERIOR WOOD CASING AND GYPSUM BOARD. FILL WALL VOIDS WITH INSULATION. PAINT TO MATCH EXISTING FINISHES. PROVIDE PAINTED WOOD BASE.

3. PROVIDE NEW DOOR ACCESS CONTROL FROM ELECTRICAL CLOSET IN KINDERGARTEN CORRIDOR TO NEW ELECTRIC STRIKES FOR CARD READER / KEY FOB SYSTEM. PROVIDE NEW ELECTRONIC COMPONENTS AND ALL LOW VOLTAGE WIRING FROM HONEYWELL NET AXS-123 ACCESS CONTROL UNIT TO NEW CARD READER LOCATIONS. REMOVE AND RESET EXISTING CARD READERS AND RUN WIRING IN NEW DOOR FRAMES. OWNER TO PROVIDE NEW DOOR ACCESS CONTROL PANEL IN ELECTRICAL CLOSET. ALL OTHER WORK BY CONTRACTOR. RUN NEW WIRING THROUGH DOOR FRAME AND STOREFRONT FRAMING TUBES. INSTALL ALL CABLING AND LOW VOLTAGE WIRING IN ACCORDANCE WITH THE MANUFACTURERS GUIDLINES AND ACCORDING TO ALL APPLICABLE BUILDING CODES AT THE TIME OF INSTALLATIONS, INCLUDING BUT NOT LIMITED TO THE NEC AND THE ANSI/TIA/EIA TELECOMMUNICATIONS BUILDING WIRING STANDARDS.

4. PROVIDE DRYER VENT KIT WITH 4" DIAMETER METAL FLEX DUCT, ELBOWS, CLAMPS AND METAL WALL VENT. INCLUDE ALL MATERIALS PROVIDED FOR COMPLETE INSTALLATION.

5. REMOVE AND REPLACE INTERIOR WOOD CASING AND GYPSUM BOARD PAINT.

6. REGRADE AREA TO DROP GRADE DOWN BELOW WOOD TRIMWORK AND FRAMING. PROVIDE 6" LOAM AND SEED AT REGRADED AREA.

7. REMOVE AND REPLACE EXISTING WOOD CASING AND SILLS FOR HAZARDOUS MATERIAL ABATEMENT.

LEGEND

CARD READER / KEY FOB SYSTEM

SHADE SYSTEM - PROVIDE NEW SHAPES AT AREAS MARKED ON FLOOR PLAN

SH

CR

AREA AT EXISTING WOOD CASING TO BE REMOVED

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

M -

WIN

DO

W &

DO

OR

RE

PL

AC

EM

EN

T

WING A

WING B

WING C

KEY PLAN KEY PLAN

As indicated

1/2

3/2

018

11:1

2:1

2 A

M

A-101

FLOOR PLAN

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/16" = 1'-0"B1

FIRST FLOOR PLAN

1/16" = 1'-0"A1

WING C - SECOND FLOOR PLAN

1992 ADDITION

1964ADDITION

1992 ADDITION

1958 BUILDING

1992 ADDITION

COURTYARD

1/8" = 1'-0"D1

BASEMENT - STORAGE AREA

1975 TOWN

LIBRARY (NIC)

1975 TOWN

LIBRARY (NIC)

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

1

1

1

1

Page 17: HALIFAX ELEMENTARY SCHOOL

EXISTING RAKE BOARDS TO REMAIN

FIBER CEMENT (FC) SIDING (TYP)

FIXED ALUMINUM WINDOW WITH 1x6 PVC TRIM

W/MOLDING & DRIP CAP & PVC SILL

NEW 5/4X12 PVC CORNER BOARD (TYP AT GYM)

PVC PANEL

ALUMINUM ENTRY DOORS W/ALUMINUM STOREFRONT FRAME & TRANSOM

FIXED ALUMINUM WINDOW (TYP)ALUMINUM FRAME STOREFRONT

FIXED ALUMINUM WINDOW (TYP)

FIXED ALUMINUM WINDOW OVER AWNING WINDOW (TYP)

EXISTING CONCRETE FOUNDATION WALL

5/4"X12 PVC TRIM (TYP)

EXISTING GRILL TO BE REMOVED & RESET

ALUMINUM ENTRY DOORS W/ALUMINUM STOREFRONT FRAME

EXISTING FASCIA/CORNICE TO REMAIN (SCRAPE & PAINT)

WRAP EXISTING WOOD SILL / TRIM WITH W/ALUMINUM

F.C. SIDING 5/4X8 PVC CORNER BOARDAT BOTH SIDES

SF2 SF2

A-210

B2

EXISTING LOUVER

EXISTING FASCIA/CORNICE TO REMAIN (SCRAPE & PAINT)

A-210

B5A-210

C4

PVC CORNER BOARDS

1

6

7

LF LF LF LF

UVG UVG UVG

5

107108 106

105

LF LFDB

LS

5

X

W

C

X X X X X X X X

W W W W WD

SSSSS A

A-210

C5

SF1

A-210

A4

A-210

A2

11 TYP.

SF5SF5 FROSTED GLASS

TINTED GLASS

SF11 SF11 SF11 SF11

LIBRARY N.I.C

EXISTING STUCCOFROSTED GLASS

HALIFAX ELEMENTARY SCHOOL

464

A A

WRAP EXISTING WOOD SILL / TRIM W/ALUMINUM AT WINDOW TYPE- A,B,S,T TYPICAL

EXISTING LOUVER - PROVIDE 1X4 PVC TRIM

NEW F.C. SIDING

EXISTING FASCIA/CORNICE TO REMAIN-SCRAPE & PAINT

ALUMINUM ENTRY DOORS W/STOREFRONT FRAME & TRANSOM

EXISTING PILASTERS & TRIM TO REMAIN (SCRAPE & PAINT)

CUSTOM FIXED ALUMINUM WINDOW IN EXISTING FRAME-SCRAPE & PAINT EXISTING TRIM

FIXED ALUMINUM WINDOW IN FORMER DH OPENING-WRAP HEAD, JAMB, SILL W/ALUMINUM

ALUMINUM ENTRY DOORS W/ALUMINUM STOREFRONT SIDELIGHTS & TRANSOMS

ALUMINUM ENTRY DOOR

C H

DBB

104

ORV

LFT

8

1

5

EB

FDCPIPE SUPPORT

JB JB

BELL

LF LF

1

103

LF

HB

SF8

100 101

5

102

II II

1UVG

T

9

F

10

10PROVIDE NEW 5/4 x 6 PVC BASE & MOULDING

SF10

1X12 PVC C.B.

PVC SILL

PVC TRIM W/MOLDING & DRIP CAP (TYP)

NEW FC SIDING

VHLF

8

LF

1

1X8 PVC1X8 PVC

2

SF2 SF2 SF2

A-210

A1

PROVIDE 1X4 PVC & FLASHING ABOVE EXISTING STEP FLASHING

PVC PANELS, TRIM BOARDS & MOULDING

A-210

B4

EXISTING WD PANELS & TRIM TO REMAIN, REPAIR & PAINT

PVC TRIM & MOLDING

PVC PANEL (TYP)

1XPVC TRIM

PVC MOLDING (TYP)

A-210

B1

AUTOMATIC DOOR BUTTOM

A-210

B3

1X8 PVC CB

EXISTING FASCIA & CORNICE TO REMAIN (SCRAPE & PAINT)

5/4X8 PVC

EXISTING WOOD PANELS & TRIM TO REMAIN, REPAIR & PAINT

EXISTING BRICK

5

A-210

B6

EXISTING STUCCO

EXISTING FASCIA/CORNICE TO REMAIN-SCRAPE & PAINT

FIXED ALUMINUM WINDOW IN FORMER DH OPENING- WRAP WOOD, SILL W/ALUMINUM

5/4"X8" PVC CB

F.C. SIDING T

1

58

VH

9

ALUMINUM FIXED WINDOW OVER AWNING

FC SIDING

5/4"X8" CB PVC

WRAP EXISTING WOOD SILL / TRIM WITH ALUMINUM-PROFILE TO MATCH EXISTING -TYPICAL

LF

LS

1

5

S S S

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

WING A

WING B

WING C

KEY PLAN KEY PLAN

1/8" = 1'-0"

1/2

3/2

018

11:1

2:2

0 A

M

A-201

EXTERIORELEVATIONS

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/8" = 1'-0"D4

WING A - NORTH - NEW

1/8" = 1'-0"C1

WING B - NORTH - NEW

1/8" = 1'-0"A1

WING A - E - NEW 1/8" = 1'-0"

A2WING A - F - NEW

1/8" = 1'-0"A3

WING B - I - NEW 1/8" = 1'-0"

A4WING B - J - NEW

1/8" = 1'-0"B1

WING A - A - NEW 1/8" = 1'-0"

B2WING A - B - NEW

1/8" = 1'-0"B3

WING A- C - NEW 1/8" = 1'-0"

B4WING A - D - NEW

1/8" = 1'-0"B5

WING B - K - NEW

1/8" = 1'-0"B6

WING B - L - NEW

D1

B1 B2

B3 B4

B5

B6

C1

A1A2

A3

A4

1992 ADDITION

1964ADDITION

1992 ADDITION

1958 BUILDING

1992 ADDITION

COURTYARD

B3

NOTE: RAINWATER LEADERS NOT SHOWN FOR CLARITY. SEE DEMOLITION DRAWINGS FOR RWL LOCATIONS.

ELEVATION KEY NOTESNUMBER DESCRIPTION

1 PROVIDE 1X6 PVC WATER TABLE

2PROVIDE NEW SIDING AT SIDES OF ENTRANCE CANOPY - SCRAPE ANDPAINT RAKE BOARD AND FASCIA.

3PROVIDE FRAMED PVC PANEL AT LIGHT SCONCES AS SHOWN ONDRAWING A-531.

4SCRAPE AND PAINT EXISTING LOUVER - PROVIDE NEW SEALANT ATPERIMETER.

5 SCRAPE AND PAINT EXISTING WOOD CORNICE AND TRIMWORK.

6 PROVIDE 1X12 PVC TRIM BOARD CUT TO FIT AREA ABOVE VESTIBULE

7PROVIDE 1X8 PVC TRIM BOARD CUT TO FIT AREA BETWEENSTOREFRONT FRAME AND WALL

8PROVIDE DRYER VENT AND HOSE KIT. MOUNT VENT ON 1X PVC TRIMBOARD ADJACENT TO WINDOW (3'-0" MINIMUM ABOVE GRADE MIN)

9 SCRAPE, PATCH, PREP, CLEAN AND PAINT EXISTING STUCCO.

10 PRIME AND PAINT EXISTING TRIMWORK AND MOLDING AT DOOR.

11

PROVIDE 1/2" PVC PANEL AND TRIMBOARD WITH RABBETTED BACKCUTS. PANEL LOCATIONS TO MATCH EXISTING. INSTALL PVC PANELSAND TRIM BOARDS OVER AIR/VAPOR BARRIER. RUN AIR BARRIERCONTINUOUS INTO WINDOW FRAME.

12 WRAP WALL BUMP-OUT IN PVC 1X TRIMBOARDS.

13 REMOVE DOOR AND HARDWARE - FRAME TO REMAIN.

14RESET AIR CONDITIONING UNIT ON EXISTING BRACKETS ANCHOREDTO WALL.

1975 TOWN

LIBRARY (NIC)

10

PVC PANEL

PVC TRIM

PVC BASE CAP MOULDING

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

1

Page 18: HALIFAX ELEMENTARY SCHOOL

C C C C

SF2

ALUMINUM ENTRY DOORS IN ALUMINUM STOREFRONT W/SIDELIGHTS & TRANSOM

O.H. DOOR

FIXED ALUMINUM WINDOWS

5/4X8 PVC CB

SF1

109

110111

LF

BELL

2

LF

LF

1

VH

FUEL OIL FILL PIPE & VENT

1x6 PVC WATER TABLE -PROVIDE 1X3 PVC TRIMTO CLOSE GAP AT BOTTOMOF WATER TABLE - TYPICAL

E E EE

EXISTING BRICK WALL

LF

3

LF

ELECTRICAL OUTLET

1

5/4X12 PVC C.B.

5/4X12 PVC C.B.

SF3A

112SF3

FC SIDING

EXISTING FASCIA TO REMAIN

5/4X6" PVC CB (TYP)

PVC (OR FC) PANELS W/1XPVC TRIM ABOVE & BELOW WINDOWS

5/4X12 PVC

GRILLE (TYP) W/PVC TRIM EXISTING DOOR & FRAME

EXISTING MTL FASCIA & SOFFIT TO REMAIN

FC SIDING

5/4X12 PVC TRIM

PVC PANEL W/1XPVC TRIM

5

LF

31

114 UVG UVG UVG UVG UVG

LF

3

113

5

9

GG

G G

GG

G G

GG

G G

GG

G G

GG

G GPROVIDE PVC PANEL, 1X TRIM BOARDS AND MOLDING - TYPICAL

A-210

A3

11 TYP.

NEW FC SIDING

EXISTING FASCIA TO REMAIN

1X6 PVC CB (TYP)

ALUMINUM ENTRY DOORS IN ALUMINUM FRAME

LIBRARY, N.I.C

3

LF

131

1

FP

HB

EXISTING FASCIA & SOFFIT TO REMAIN

5/4X12 PVC

FC SIDING

PVC PANEL W/1XPVC TRIM ABOVE & BELOW WINDOWS (TYP)

PVC PANELEXISTING GRILLE - REMOVE & RESET (TYP)

1X6 PVC CB

3

LF

3

1

125

LF

EO

HS

5

GG

G G

GG

G G

GG

G G

GG

G G G

G

11 TYP.

ALL TINTED GLASS

UVG UVG UVG UVG UVG

LF

1

5

SSS

PROVIDE PVC PANEL, 1 X TRIM BOARDS AND MOULDING - TYP

1

EXISTING FASCIA TO REMAIN

PVC SIDING

1X6 PVC C.B.

1

1X6 PVC CB

UVG

III I

1

102

FC SIDING & PVC TRIM BOARDS - TYP

EXISTING LIBRARY WINDOW

EXISTING LIBRARY TRIM BOARDS

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

WING A

WING B

WING C

KEY PLAN KEY PLAN

1/8" = 1'-0"

1/2

3/2

018

11:1

2:2

8 A

M

A-202

EXTERIORELEVATIONS

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/8" = 1'-0"D1

WING A - EAST - NEW 1/8" = 1'-0"

D2WING A - SOUTH - NEW

1/8" = 1'-0"C1

WING C - EAST - NEW

1/8" = 1'-0"B1

WING B - WEST - NEW - 2 1/8" = 1'-0"

B2WING B- WEST - NEW 3

1/8" = 1'-0"A1

WING B - A - NEW 1/8" = 1'-0"

A2WING B - B- NEW

1/8" = 1'-0"A3

WING B - D - NEW 1/8" = 1'-0"

A4WING B - E - NEW

1/8" = 1'-0"A5

WING B - F - NEW

A3

A2

A1

A6

A4A5

B1

B2

D1

C1

D2

C1

1/8" = 1'-0"A6

WING B - C - NEW

1992 ADDITION

1964ADDITION

1992 ADDITION

1958 BUILDING

1992 ADDITION

COURTYARD

NOTE: RAINWATER LEADERS NOT SHOWN FOR CLARITY. SEE DEMOLITION DRAWINGS FOR RWL LOCATIONS.

ELEVATION KEY NOTESNUMBER DESCRIPTION

1 PROVIDE 1X6 PVC WATER TABLE

2PROVIDE NEW SIDING AT SIDES OF ENTRANCE CANOPY - SCRAPE ANDPAINT RAKE BOARD AND FASCIA.

3PROVIDE FRAMED PVC PANEL AT LIGHT SCONCES AS SHOWN ONDRAWING A-531.

4SCRAPE AND PAINT EXISTING LOUVER - PROVIDE NEW SEALANT ATPERIMETER.

5 SCRAPE AND PAINT EXISTING WOOD CORNICE AND TRIMWORK.

6 PROVIDE 1X12 PVC TRIM BOARD CUT TO FIT AREA ABOVE VESTIBULE

7PROVIDE 1X8 PVC TRIM BOARD CUT TO FIT AREA BETWEENSTOREFRONT FRAME AND WALL

8PROVIDE DRYER VENT AND HOSE KIT. MOUNT VENT ON 1X PVC TRIMBOARD ADJACENT TO WINDOW (3'-0" MINIMUM ABOVE GRADE MIN)

9 SCRAPE, PATCH, PREP, CLEAN AND PAINT EXISTING STUCCO.

10 PRIME AND PAINT EXISTING TRIMWORK AND MOLDING AT DOOR.

11

PROVIDE 1/2" PVC PANEL AND TRIMBOARD WITH RABBETTED BACKCUTS. PANEL LOCATIONS TO MATCH EXISTING. INSTALL PVC PANELSAND TRIM BOARDS OVER AIR/VAPOR BARRIER. RUN AIR BARRIERCONTINUOUS INTO WINDOW FRAME.

12 WRAP WALL BUMP-OUT IN PVC 1X TRIMBOARDS.

13 REMOVE DOOR AND HARDWARE - FRAME TO REMAIN.

14RESET AIR CONDITIONING UNIT ON EXISTING BRACKETS ANCHOREDTO WALL.

1975 TOWN

LIBRARY (NIC)

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 19: HALIFAX ELEMENTARY SCHOOL

NEW DOORS

TYPICAL WINDOW TRIM-1X4 PVC JAMBS & HEAD W/ALUMINUM DRIP CAP AT HEAD, PVC SILL

1X6 PVC TRIM W/ALUMINUM DRIPCAP (TYP@4 LOCATIONS)

FC SIDING

EXISTING STONE VEENER

NEW PREFIN ALUMINUM FLASHING OVER P.T. WD BLOCKING AT STONE VENEER (TYP)

ALUMINUM FIXED OVER AWNING WINDOWS (TYP)

1X6 PVC CB (TYP)

FIXED ALUMINUM WINDOWS

1x4 PVC

1X4 PVC TRIM W/ALUMINUM DRIP CAP

NEW PVC SILL

EXISTING FASCIAS & SOFFITS TO REMAIN

PVC OR FC PANEL W/PVC TRIM

EXISTING STONE VENEER

RECESSED RECESSED ±2'-0" RECESSED RECESSED

L L

K K QQ

UVG

UVG UVG

UVG UVG

UVG UVG

UVGUVG

UVG

UVG

UVG UVG

UVG UVG

UVG UVG

UVG

R

LF

LFLF

33

3

UVG UVG

124 123 124 123 124 123 124 123

1111

EB

L L

K K

L L

K K

L L

K K

SF13 SF13 SF13 SF13

12

12 12

12

ALL TINTED GLASS

13

ALUMINIUM ENTRY DOOR W/ALUMINUM FRAME (TYP)

120 136 135 119

LF

SIDING W/1X6 PVC CB AT CHEEK WALLS (TYP)

FC SIDING

1X6 PVC CB 1

PROJECTING CANOPY BEYOND

1X6 PVC CB

FC SIDING

WING "C" BEYOND

FC SIDING (TYP)

1X6 PVC CB

1X6 PVC CB

D D D

1P

1

WING "A" BEYOND

EXISTING DOOR & FRAME

FC SIDING (TYP)

1X6 PVC CB

1

138137

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

KEY PLAN

1/8" = 1'-0"

1/2

3/2

018

11:1

2:3

4 A

M

A-203

EXTERIORELEVATIONS

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/8" = 1'-0"D1

WING C - SOUTH - NEW

1/8" = 1'-0"C1

WING C - A - NEW 1/8" = 1'-0"

C2WING C - B - NEW

1/8" = 1'-0"C3

WING C - C - NEW 1/8" = 1'-0"

C4WING C - D - NEW

1/8" = 1'-0"C5

WING C - E - NEW 1/8" = 1'-0"

C6WING C - F - NEW

1/8" = 1'-0"B1

WING C - G - NEW 1/8" = 1'-0"

B2WING C - H - NEW

1/8" = 1'-0"B3

WING C - I - NEW 1/8" = 1'-0"

B4WING C - J - NEW

1/8" = 1'-0"A1

WING C - NORTH - NEW 2 1/8" = 1'-0"

A2WING A - SOUTH - NEW 2

A1

A2

B3C5

B4

A1

A2

C2B1 C6 C1C4

C3B2D1

NOTE:KEY-INS ARE NOT ALL SHOWN FOR CLARITY. SOUTH ELEVATION IS SYMETRICAL

1992 ADDITION

1964ADDITION

1992 ADDITION

1958 BUILDING

1992 ADDITION

COURTYARD

NOTE: RAINWATER LEADERS NOT SHOWN FOR CLARITY. SEE DEMOLITION DRAWINGS FOR RWL LOCATIONS.

ELEVATION KEY NOTESNUMBER DESCRIPTION

1 PROVIDE 1X6 PVC WATER TABLE

2PROVIDE NEW SIDING AT SIDES OF ENTRANCE CANOPY - SCRAPE ANDPAINT RAKE BOARD AND FASCIA.

3PROVIDE FRAMED PVC PANEL AT LIGHT SCONCES AS SHOWN ONDRAWING A-531.

4SCRAPE AND PAINT EXISTING LOUVER - PROVIDE NEW SEALANT ATPERIMETER.

5 SCRAPE AND PAINT EXISTING WOOD CORNICE AND TRIMWORK.

6 PROVIDE 1X12 PVC TRIM BOARD CUT TO FIT AREA ABOVE VESTIBULE

7PROVIDE 1X8 PVC TRIM BOARD CUT TO FIT AREA BETWEENSTOREFRONT FRAME AND WALL

8PROVIDE DRYER VENT AND HOSE KIT. MOUNT VENT ON 1X PVC TRIMBOARD ADJACENT TO WINDOW (3'-0" MINIMUM ABOVE GRADE MIN)

9 SCRAPE, PATCH, PREP, CLEAN AND PAINT EXISTING STUCCO.

10 PRIME AND PAINT EXISTING TRIMWORK AND MOLDING AT DOOR.

11

PROVIDE 1/2" PVC PANEL AND TRIMBOARD WITH RABBETTED BACKCUTS. PANEL LOCATIONS TO MATCH EXISTING. INSTALL PVC PANELSAND TRIM BOARDS OVER AIR/VAPOR BARRIER. RUN AIR BARRIERCONTINUOUS INTO WINDOW FRAME.

12 WRAP WALL BUMP-OUT IN PVC 1X TRIMBOARDS.

13 REMOVE DOOR AND HARDWARE - FRAME TO REMAIN.

14RESET AIR CONDITIONING UNIT ON EXISTING BRACKETS ANCHOREDTO WALL.

1975 TOWN

LIBRARY (NIC)

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 20: HALIFAX ELEMENTARY SCHOOL

LFLF

UVGUVGUVGUVG

UG

GG

GG

GG

GG

GG

GG

GG

G

134

EXISTING DOOR & FRAME11 TYP.

O

LF LF

FC SIDING

NGG

GG

GG

GG

GG

GG

GG

GG

5

UVG UVG UVG UVG

132

LF

GG GG

PVC PANEL AND TRIM BOARDSAT ALCOVE WALLS FC SIDINGFC SIDING

MN M N M M N

5 5

FROSTED GLASS AT TOILET ROOMS

5

11 TYP.

EXISTING FASCIA/CORNICE TO REMAIN-SCRAPE & PAINT

FC SIDING

5/4X6 PVC CB (TYP)

TYPICAL WINDOW TRIM-1X4 PVC JAMS & HEAD W /ALUMINUM DRIP CAP AT HEAD, PVC SILL

FC SIDINGFIXED ALUMINUM WINDOW

ALUM. BETWEEN UNITS

FIXED ALUMINUM WINDOW

D D D D D D

P

SF6 SF6 SF6 SF6

SF12

P

SF12SF12 SF12 SF12 SF12

5/4X12 PVC

FC SIDING

WINDOW ALUMINUM FIXED OVER AWNING

EXISTING FASCIA/CORNICE TO REMAIN-SCRAPE & PAINT

1X6 PVC CB1X6 PVC CB (TYP) 1X6 PVC CB

TYP WINDOW TRIM-1X4 PVC JAMBS & HEAD

ALUMINUM ENTRY DOOR IN EXISTING FRAME

EXISTING STONE VENEER

PREFIN ALUMINUM FLASHING AT STONE VENEER (TYP)

LF

UVGUVG UVGUVG

3 4 EXISTING LOUVER

JJJ J

11

FP

ED HHHHHHHHHHHH

ALL TINTED GLASS

126

NEW WORK GENERAL NOTES

1 PROVIDE 3/4" X 3/4" PVC TRIM AT ALL INSIDE CORNERS FOR SIDING TERMINATION.

2 PROVIDE MINERAL WOOL INSULATION AT THE HEAD AND JAMBS OF NEW WINDOW FRAMES. DO NOT INSTALL INSULATION AT SILL OR AT THE LOWER 1'-0" OF JAMBS TO ALLOW FOR WEEPING OF FRAMES.

3. PAINT EXISTING UNIT VENTILATOR GRILLES WHITE PRIOR TO REINSTALLATION, MATCHING SIDING/TRIMBOARDS.

4. PROVIDE NEW CONTINUOUS AIR/VAPOR MEMBRANE AT ALL NEW SIDING AND TRIMWORK. PROVIDE NEW MEMBRANE FLASHING AT ALL NEW WINDOW AND DOOR OPENINGS. MEMBRANE FLASHING TO OVERLAP AIR/VAPOR MEMBRANE.

5. PROVIDE NEW FIBER CEMENT SIDING AND PVC TRIMBOARDS AT ALL LOCATIONS OF EXISTING WOOD SIDING AND TRIMBOARDS, EXCEPT WHERE NOTED TO REMAIN ON DRAWINGS.

6. REFER TO DRAWING A210 FOR WINDOW TRIMWORK REQUIREMENTS.

7. PAINT ALL NEW & EXISTING INTERIOR WINDOW SILLS, CASING AND APRONS.

8. REINSTALL ALL LIGHT FIXTURES, ELECTRICAL DEVICES, FIRE ALARM DEVICES, GONG, FAUCETS, ETC. ON PVC PLINTH BLOCKS.

9. REPLACE EXISTING WOOD INTERIOR WINDOW TRIM AT LOCATIONS WHERE TRIM INTERFERES WITH PLACEMENT OF NEW WINDOW SYSTEM.

10. PROVIDE SOLID WOOD BLOCKING AT GAPS IN INTERIOR WOOD CASING THAT WILL BE COVERED WITH NEW WINDOW SNAP TRIM.

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

WING A

WING B

WING C

KEY PLAN KEY PLAN

As indicated

1/2

3/2

018

11:1

2:4

0 A

M

A-204

EXTERIORELEVATIONS

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/8" = 1'-0"A1

INTERIOR COURTYARD - VIEW LOOKING EAST - NEW

1/8" = 1'-0"A2

INTERIOR COURTYARD - VIEW LOOKING WEST - NEW

1/8" = 1'-0"B1

INTERIOR COURTYARD - VIEW LOOKING NORTH - NEW

1/8" = 1'-0"C1

INTERIOR COURTYARD - VIEW LOOKING SOUTH - NEW

1/8" = 1'-0"D1

WING B - SOUTH - NEW

A2

C1

A1 A2

B1 D1

1992 ADDITION

1964ADDITION

1992 ADDITION

1958 BUILDING

1992 ADDITION

COURTYARD

ELEVATION KEY NOTESNUMBER DESCRIPTION

1 PROVIDE 1X6 PVC WATER TABLE

2PROVIDE NEW SIDING AT SIDES OF ENTRANCE CANOPY - SCRAPE ANDPAINT RAKE BOARD AND FASCIA.

3PROVIDE FRAMED PVC PANEL AT LIGHT SCONCES AS SHOWN ONDRAWING A-531.

4SCRAPE AND PAINT EXISTING LOUVER - PROVIDE NEW SEALANT ATPERIMETER.

5 SCRAPE AND PAINT EXISTING WOOD CORNICE AND TRIMWORK.

6 PROVIDE 1X12 PVC TRIM BOARD CUT TO FIT AREA ABOVE VESTIBULE

7PROVIDE 1X8 PVC TRIM BOARD CUT TO FIT AREA BETWEENSTOREFRONT FRAME AND WALL

8PROVIDE DRYER VENT AND HOSE KIT. MOUNT VENT ON 1X PVC TRIMBOARD ADJACENT TO WINDOW (3'-0" MINIMUM ABOVE GRADE MIN)

9 SCRAPE, PATCH, PREP, CLEAN AND PAINT EXISTING STUCCO.

10 PRIME AND PAINT EXISTING TRIMWORK AND MOLDING AT DOOR.

11

PROVIDE 1/2" PVC PANEL AND TRIMBOARD WITH RABBETTED BACKCUTS. PANEL LOCATIONS TO MATCH EXISTING. INSTALL PVC PANELSAND TRIM BOARDS OVER AIR/VAPOR BARRIER. RUN AIR BARRIERCONTINUOUS INTO WINDOW FRAME.

12 WRAP WALL BUMP-OUT IN PVC 1X TRIMBOARDS.

13 REMOVE DOOR AND HARDWARE - FRAME TO REMAIN.

14RESET AIR CONDITIONING UNIT ON EXISTING BRACKETS ANCHOREDTO WALL.

NOTE: RAINWATER LEADERS NOT SHOWN FOR CLARITY. SEE DEMOLITION DRAWINGS FOR RWL LOCATIONS.

1975 TOWN

LIBRARY (NIC)

11 TYP.

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

1

1

Page 21: HALIFAX ELEMENTARY SCHOOL

PVC MOULDING 3 - (4" CROWN) - PROVIDE MITERED END RETURNS

1 x PVC (PROVIDE MITERED END RETURNS)

1'-7

"

5"

10"

3"

PVC MOULDING 4 -TYP.

PREFINISHED ALUMINUM FLASHING

5/4" x PVC CAP - SLOPED

1 x 12 PVC (PROVIDE MITERED END RETURNS)

1/2" PVC PANEL -TYP.5/4" x PVC AT PILASTER SIDES -TYP.

5/4" x 12 PVC -TYP.

6"

WRAP EXISTING APRON WITH BRAKE ALUMINUM

PVC MOULDING 53" CROWN 5/4" x 3" PVC

CAP-SLOPED

PREFINISHED ALUMINUM FLASHING

NOTE: NO CROWN REQUIRED AT CAFETERIA B157

WRAP EXISTING WOOD SILL AND TRIM BOARDS WITH BRAKE ALUMINUM - PROFILE TO MATCH EXISTING

5 1/2"

5 1

/2"

3 1

/2"

NOTE:

PROVIDE IN-PLACE MOCKUP OF TWO WINDOWS AND TRIMWORK CONTAINED IN THIS ELEVATION.

ALIGNTRIMBOARDS -TYPICAL

EXISTING CONTINUOUS WOOD SILL TO BE WRAPPED IN ALUMINUM

EXISTING CONTINUOUS WOOD BASE TO BE WRAPPED IN ALUMINUM

EXISTING FOUNDATION WALL

D4

A-531

D4

A-531

10

1/2

"

1/2" PVC PANEL TYP.

9"

8'-1

1 1

/2"

±9

"1

'-6 9

/16

"9

"7

'-11

15/1

6"

±9

"1

'-6

"1

'-7

"9

"

23

'-9"

±

PVCMOULDING 1-TYPICAL

9"

8"

1'-8

"9

"3

'-2

"9

"2

'-4

"9

"

10

'-10

" ±

5'-3" ±

5 3/4" 8" 3'-5 5/16" ± 8"

PVC MOULDING 1TYPICAL

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

1/2" = 1'-0"

1/2

3/2

018

11:1

2:4

5 A

M

A-210

ENLARGEDEXTERIOR

ELEVATIONS

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/2" = 1'-0"B2

GYMNASIUM ENTRANCE

1/2" = 1'-0"C4

CAFETERIA

1/2" = 1'-0"B5

DOOR 105 @ A25 - CORRIDOR

1/2" = 1'-0"C5

TYPICAL WINDOW TRIM

1/2" = 1'-0"A4

ART WINDOW (MOCKUP) 1/2" = 1'-0"

A2GYMNASIUM LOBBY

1/2" = 1'-0"B3

GYMNASIUM ENTRANCE - SIDE 02 1/2" = 1'-0"

B1GYMNASIUM ENTRANCE - SIDE 01

1/2" = 1'-0"B6

DOOR 105 - SIDE 02 1/2" = 1'-0"

B4DOOR 105 - SIDE 01

1/2" = 1'-0"A1

GYMANSIUM LOBBY - SIDE 01 1/2" = 1'-0"

A3GYMANSIUM LOBBY - SIDE 02

ALIGN

ALIGN

PVC MOULDING 4-TYP.

1 x PVC PANEL

PREFINISHED ALUMINUM FLASHING

MITER CORNERS

PVC MOULDING 1

1x6 PVC TRIM @ GYM

1x5 PVC TRIM @ 1958 & 1964 BUILDING

1x4 PVC TRIM @ ALL OTHER LOCATIONS

PVC SILL

1 x 4 PVC APRON(DOUBLE AT GYM)

EXISTING TRIM (SCRAPE & PAINT)

PVC MOULDING 1

1 x PVC TRIM

PVC MOULDING 2 (PROVIDE MITERED END RETURNS)

1 x 6 PVC PLINTH BLOCK(PROVIDE MITERED END RETURNS) -TYP.

EXISTING PILASTERS (SCRAPE & PAINT)

5/4 x PVC TRIM -TYPICAL

FIXED ALUMINUM WINDOW

FIXED ALUMINUM WINDOW

1/2" PVC PANEL

UVG

EXISTING WOOD CORNICE 1 x 12 PVC TRIM (PROVIDE MITERED END RETURNS)

1 x PVC TYP.

PVC MOULDING 1-TYP.

NOTE: REFER TO DRAWING A-511 FOR PVC MOULDING TYPES AND DIMENSIONS

AWNING ALUMINUM WINDOW

EXISTING WOOD FRIEZE BOARDS TO BE PREPPED & PAINTED

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 22: HALIFAX ELEMENTARY SCHOOL

4'-5

" ±

4'-4 1/8" ±

3'-5" ±

3'-1

1"

±2

'-1

" ±

6'-0

" ±

C4

A-511

SIM

B4

A-511

SIM

A4

A-511

SIM

3'-1 1/2" ±

2'-7

1/2

" ±

C2

A-511

SIM

B2

A-511

A2

A-511

3'-3

1/2

" ±

2'-0" ±

2'-6

" ±

C4

A-511

SIM

B4

A-511

SIM

A4

A-511

SIM

5'-4" ±

C4

A-511

SIM

B4

A-511

SIM

AWNING PROJECT OUT

8'-6

" ±

5'-7

" ±

2'-9

" ±

5'-5

1/4

" ±

4'-4 3/4" ±

C4

A-511

SIM

B4

A-511

SIM

8'-1

1 3

/4"

±

C5

A-511

B5

A-511

B4

A-511

SIM

A4

A-511

SIM

J JJ J

6'-4

" ±

5'-4 1/8" ±

EQ EQ

5'-4 1/8" ±

EQEQ

REFER TO DWG A-502 FOR STOREFRONT DOOR/TRANSOM

EXISTING POST

HOPPER -PROJECT IN WITH POLE OPERATED CAM HANDLE

3 1/2" 3 1/2"

D2

A-511

C5

A-511

B4

A-511

SIM

B5

A-511

A4

A-511

SIM

A3

A-513

SIM

K

8'-0 1/2" ±

1'-9

"4

'-7

" 6'-4

" ±

EQ EQ EQ

HOPPER -PROJECT IN WITH POLE OPERATED CAM HANDLE

K K

D3

A-511

EQ 3 3/4" EQ

C4

A-513

B4

A-513

A4

A-513

B3

A-513

AWNING PROJECT OUTG GG G

EQ3 3/4"

13'-6 3/4" ±

5'-9

1/4

" ±

3'-4

1/8

" ±

2'-5

1/8

" ±

MM

AWNING PROJECT OUT

EQ 3 3/4" EQ

8'-11 1/4" ±

5'-9

1/4

" ±

3'-4

1/8

" ±

2'-3

1/8

" ±

AWNING PROJECT OUT

4'-3 3/4" ±

5'-9

1/4

" ±

4'-0

" ±

2'-4 3/8" ±

C4

A-511

SIM

B4

A-511

SIM

A4

A-511

SIM

8'-0 1/2" ±

A3

A-513

SIM

D1

A-511

@ DOOR

A5

A-511

B4

A-511

SIM

4'-6

" ±

EQ EQ EQ

2'-11

"1

'-7

"

H H H

AWNING -PROJECT OUT

EQ EQ 3 1/2"

24'-1" ±

C4

A-511

SIM

A4

A-511

SIM

C3

A-512

SIM

B4

A-511

SIM

EXISTING STRUCTURAL POST

3'-1

1"

±

EQ 5 1/2" EQ EQ EQ3 1/2"

EXISTING STRUCTURAL POST

NOTE: ALL TINTED GLASS

9'-2

1/4

" ±

9'-2 1/4" ±

C5

A-511

B4

A-511

SIM

B5

A-511

A4

A-511

SIM

EQ EQ EQ

HOPPER -PROJECT IN WITH POLE OPERATED CAM HANDLE

2'-3

" ±

6'-1

1 1

/4"

±

PROVIDE STEELPLATE REINFORCING BETWEEN UNITS AT MULLIONS

2'-0

"4

'-3 1

/4"

6'-3

1/4

" ±

4'-4 1/4" ±

D4

A-511

AWNING PROJECT OUT

C4

A-511

SIM

B5

A-511

A5

A-511

C3

A-512

SIM

AWNING PROJECT OUT

5'-6

" ±

11'-7 1/4" ±

I II I

3'-8" 3'-8"3'-8 1/4"3 1/2" 3 1/2"

A-513

4'-4 1/4" ±

6'-3

1/4

" ±

A3

A-512

SIM

3'-3" ±

3'-3

" ±

A3

A-512

SIM

B4

A-511

SIM

A4

A-511

SIM

WINDOW & DOOR NOTES:

1. VERIFY ALL DIMENSIONS IN FIELD BEFORE START OF WORK.2. WINDOW MANUFACTURER TO SUPPLY DEEPER REINFORCED MULLION FOR WIND LOADING AT

WINDOWS MARKED.3. SEE ELEVATIONS ON DRAWINGS A-201, A-202, A-203, & A-204 FOR OBSCURE FROSTED GLASS

AND TINTED GLASS LOCATIONS.4. PROVIDE REMOVABLE INTERIOR VERTICAL MULLIONS AT DOUBLE DOORS.5. PROVIDE INTERIOR WINDOW SCREENS AT AWNING (OUTSWING) WINDOW PANELS, AND

EXTERIOR WINDOW SCREENS AT HOPPER (IN-SWING) WINDOW PANELS.6. PROVIDE 1" INSULATED TEMPERED GLASS AT ALL GLAZED OPENINGS INCLUDING DOORS,

SIDELIGHTS, AND TRANSOMS - TYPICAL UNLESS OTHERWISE NOTED.7. WINDOW GRILLES (MUNTINS) TO BE INSTALLED BETWEEN THE GLAZING.8. PROVIDE WINDOW SNAP TRIM AT ALL WINDOWS TYPES.9. PROVIDE 1" WIDE GRILL MUNTINS PAINTED WHITE AT ALL WINDOW & STOREFRONT.

3'-5 3/4" ±

1'-9

" ±

4'-6

1/4

" ±

4'-4" ±

EQ

EQ

FIXED PANEL

AWNNGPROJECT OUT

C4

A-511

SIM

B4

A-511

SIM

A4

A-511

SIM

AWNING PROJECT OUT4'-4 1/8" ±

4'-5

" ±

FIXED

C4

A-511

SIM

B4

A-511

SIM

C4

A-511

SIM C4

A-511

SIM

B4

A-511

SIM

B5

A-511

A5

A-511

D3

A-511

L L L

8'-0 1/2" ±

6'-4

" ±

EQ EQ EQ

AWNING PROJECT OUT

1'-9

" ±

4'-7

" ±

PLA

N

NO

RT

HTRUE

NORTH

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

1/4" = 1'-0"

1/2

3/2

018

11:1

2:4

9 A

M

A-501

WINDOW TYPES -NEW

1614.03

12/13/17

jas

SB

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/4" = 1'-0"A

KITCHEN 1/4" = 1'-0"

CGYM OFFICE

1/4" = 1'-0"E

GYMNASIUM 1/4" = 1'-0"

FSTORAGE ROOM

1/4" = 1'-0"D

GYM TOILET/2ND FLOOR WING C

1/4" = 1'-0"S

CAFETERIA 1/4" = 1'-0"

TTOILET - WING B

1/4" = 1'-0"J

ADMINISTRATION 1/4" = 1'-0"

KCLASSROOM - WING C - FIRST FLOOR

1/4" = 1'-0"G

CLASSROOM / COURTYARD

1/4" = 1'-0"M

COURTYARD 1/4" = 1'-0"

NCOURTYARD

1/4" = 1'-0"O

COURTYARD

1/4" = 1'-0"H

KINDERGARTEN

1/4" = 1'-0"R

MEDIA CENTER - 2ND FLOOR 1/4" = 1'-0"

QMEDIA CENTER

1/4" = 1'-0"W

ART / MUSIC ROOM

1/4" = 1'-0"I

KINDERGARTEN

1/4" = 1'-0"X

ART / MUSIC ROOM

1/4" = 1'-0"P

STAIR

1/4" = 1'-0"V

KITCHEN 1/4" = 1'-0"

UJANITOR

1/4" = 1'-0"B

KITCHEN/OFFICEGG

1/4" = 1'-0"L

CLASSROOM - WING C - SECOND FLOORII

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

31

/5/1

8C

OO

RD

INA

TIO

N

3

3

Page 23: HALIFAX ELEMENTARY SCHOOL

2"

2'-0 1

/2"

4"

3'-8

"

4"

2'-3

"

9"

9'-6 1

/2"

C4

A-511

SIM

B4

A-511

SIM

A3

A-513

SIM

D3

A-512

C1

A-512

C2

A-511

SIM

SIM @ SIDE ENTRY

7'-0

"

10'-10" ±

2"3 1/2"2"

6'-0"3 1/2" 3 1/2"EQ EQ9

"6

'-3

" ±

2'-2

1/2

" ±

EXISTING STRUCTURAL HEADER -TYP

EXISTING STRUCTURAL POST-TYP

2'-4 1

/2"

4'-11

"

3'-11 1/2" ±

7'-3

1/2

" ±

C1

A-511

B1

A-511

A1

A-511

B2

A-511

A2

A-511

C2

A-511

SIM

A3

A-512

SIM

A4

A-511

SIM

B4

A-511

SIM

15'-10 1/2" ±

SF3A

SF3

SF3A

2" 3'-0" 2" 8" ±

7'-4

" ±

2'-2

" ±

7'-0

" ±

2"

2'-2

" ±

EXISTING STRUCTURAL POST

PROVIDE STEEL PLATE REINFORCING BETWEEN UNITS AT MULLIONS -TYPICAL

7'-4" ±

9'-3

" ±

VIF

2"

8'-0

"

3'-6" 3'-6"

19

'-11

" ±

3'-11" ± 3 1/2" 3'-11" ± 3 1/2" 3'-11" ± 3 1/2" 3'-11" ±

B4

A-511

SIM

A3

A-512

SIM

B3

A-512

EXISTING STRUCTURAL POST

SF6 SF6 SF6 SF6

8'-9

"3

'-11

"

12

'-8"

±

C4

A-511

SIM

B4

A-511

SIM

A5

A-511

C3

A-512

SIM

16'-8" ±

3'-11" EQ 3'-11" EQ 3'-11" EQ 3'-11"

EXISTING STRUCTURAL POSTS, TYPICAL

2'-0

"

SF13 SF13 SF13 SF13

NOTE: ALL TINTED GLASS

7'-0

"

6'-4" ±

3'-0"

8'-1

0 3

/4"

±

2"

2"

8'-6

" ±

EXISTING STRUCTURAL POSTS -TYP

EQ 3 1/2" 6'-0" 5 1/2" 6'-0" 3 1/2" EQ

17'-8" ±

EXISTING STRUCTURAL HEADER - TYP

3 1

/2"

1'-2 1

/2"

6'-3

" ±

9"

D1

A-512

D3

A-512

C1

A-512

VARIES

VA

RIE

S

VARIES

VA

RIE

S 6"

6"

6"

10"

VARIES

VA

RIE

S 6"

6"

6"

10"

A B CD E

7'-0

"

8'-0"

7'-0

"

F1F2

2"SEE SCHEDULE - VARIES

3'-0"2"

7'-0

"2

"

2"SEE SCHEDULE

2"

7'-0

"2

"

7'-0

"

6'-0

"

EXTERIOR DOOR

ADHESIVE APPLIED 4"X8" VINYL SIGNAGE, 6" HIGH EXTERIOR DOOR NUMBER ON INTERIOR AND EXTERIOR OF DOOR TO MATCH EXISTING. COORDINATE SIGN LOCATOIN ON GLAZED DOORS

NOTE : PROVIDE DOOR NUMBER SIGN AT ALL EXTERIOR DOORS

3'-1" ± 2"2"

7'-0

"

8'-11

3/4

"

4'-0" 3 1/2" 4'-0" 3 1/2" 4'-0"

A3

A-512

SIM

B4

A-511

SIM

A5

A-511

C3

A-512

SIM

12'-7" ±

11

'-3 3

/4"

±

AWNING - PROJECT OUT

EXISTING STRUCTURAL POST

1'-11

"

SF12 SF12 SF12

EQ

8'-0

" ±

3'-0

" ±

EQ 9" ±

8'-9" ±

11

'-0"

±

D2

A-512

C2

A-512

B2

A-512

A2

A-512

SF11 SF11

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

1/4" = 1'-0"

1/2

3/2

018

11:1

2:5

1 A

M

A-502

STOREFRONT -DOOR TYPES &

DOOR SCHEDULE

1614.03

12/13/17

jas

SB

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

STOREFRONT TYPES

FRAME TYPES

DOOR TYPES

1/4" = 1'-0"SF1

GYMNASIUM LOBBY 1/4" = 1'-0"

SF2GYMNASIUM

1/4" = 1'-0"SF3

GYMNASIUM LOBBY RAMP ENTRANCE 1/4" = 1'-0"

SF5GYMNASIUM FRONT ENTRANCE

1/4" = 1'-0"SF6

COURTYARD @ WING C

1/4" = 1'-0"SF13

MEDIA CENTER - 1ST FLOOR

1/4" = 1'-0"SF10

CAFETERIA ENTRANCE 1/4" = 1'-0"

SF8MAIN ENTRANCE - NORTH

DOOR NUMBER DETAIL

DOOR NOTES

1. SCREEN DOOR 133A TO BE ALUMINUM STORM DOOR WITH DOUBLE SEAL BOTTOM SWEEP, WEATHER STRIPPING, CLOSER WITH HOLD OPEN, HEAVY DUTY SCREEN STAINLESS STEEL, STAINLESS STEEL SCREWS, (NON REMOVABLE). SCREEN DOOR TO SWING TO EXTERIOR & ALUMINUM DOOR 133 TO SWING INTO THE BUILDING.

2. OVERHEAD DOOR TO BE SECTIONAL, PREFINISHED, INSULATED, 12 GUAGE, STEEL DOOR. MANUALLY OPERATED HEAVY DUTY TRACK AND HARDWARE MODEL 418 BY OVERHEAD DOOR OR APPROVED EQUAL.

3. VERIFY ALL DIMENSIONS IN FIELD.

4. ALL GLAZING TO BE TEMPERED.

5. PROVIDE NEW ELECTRIC OPERATOR FOR AUTOMATIC DOOR ENTRY SYSTEM ON DOOR 107.

1/4" = 1'-0"SF9

ADMINISTRATION 1/4" = 1'-0"

SF12COURTYARD UNIT & WING C

1/4" = 1'-0"SF11

GYMNASIUM ENTRY

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

1

Page 24: HALIFAX ELEMENTARY SCHOOL

1/2"

1/2"

3/8"

3/8"

1/2"

ROLLER SHADE

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB AND HEAD

1 1/4" 3 1/4"

1/2

"1

"

3/4" 2 3/4"

1/4

"1

/2"

4 1/2" 1 1/2"

1/2

"1

"

2 3/8" 3 5/8"

PVC MOULDING TYPE - 1

PVC SILL TYPE - B

PVC SILL TYPE - C

PVC SILL TYPE - A

1 1

/2"

4 1/2"

3 1/2"

3/4

"

6"

1 1

/2"

11/16"

1 5

/8"

NOTE: VERIFY ALL DIMENSIONS IN FIELD

3 1/2"

1 1

/ 16

"

17

/32

"

3 5/

8"

9/16"

PVC MOULDING TYPE - 4 PANEL CASING

PVC MOULDING TYPE - 2 BASE CAP

PVC MOULDING TYPE - 5 3" CROWN

PVC MOULDING TYPE - 3 4" CROWN

1 1

/8"

11/16"

2 3/

4"

9/16"

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

3" = 1'-0"

1/2

3/2

018

11:1

2:5

4 A

M

A-511

WINDOW &STOREFRONT

DETAILS

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

3" = 1'-0"A1

WINDOW SILL AT GYM - BRICK WALL0' 2" 4" 8"

3" = 1'-0"

3" = 1'-0"B1

WINDOW JAMB AT GYM - BRICK WALL

3" = 1'-0"C1

WINDOW HEAD AT GYM - BRICK WALL

0' 2" 4" 8"

3" = 1'-0"

0' 2" 4" 8"

3" = 1'-0"

3" = 1'-0"A2

WINDOW SILL AT GYM

3" = 1'-0"B2

WINDOW JAMB AT GYM

3" = 1'-0"C2

WINDOW HEAD AT GYM

0' 2" 4" 8"

3" = 1'-0"

0' 2" 4" 8"

3" = 1'-0"

0' 2" 4" 8"

3" = 1'-0"

3" = 1'-0"A4

WINDOW SILL - FIXED

3" = 1'-0"B4

WINDOW JAMB - FIXED

3" = 1'-0"C4

WINDOW HEAD - FIXED

3" = 1'-0"D1

WINDOW HEAD AT KINDERGARTEN 3" = 1'-0"

D2WINDOW HEAD AT WING C - 1ST FLOOR

3" = 1'-0"A5

WINDOW SILL - AWNING

3" = 1'-0"B5

WINDOW JAMB - AWNING OR HOPPER

3" = 1'-0"C5

WINDOW HEAD - HOPPER

3" = 1'-0"D3

TYPICAL VERTICAL MULLION-MALE/FEMALE

EXISTING FLASHING TO REMAIN

EXISTING ACOUSTIC PANEL

EXISTING WOOD CASING TO REMAIN

EXISTING CEILING TO REMAIN

METAL FLASHING

ALUMINUM STOREFRONT SYSTEM

PVC SILL TYPE - A

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

1x2 AND 1x4 PVC TRIM BOARDS

EXISTING WALL CONSTRUCTION

EXISTING WALL CONSTRUCTION

PVC MOULDING TYPE - 1, SEE D5/A-511

ALUMINUM STOREFRONT SYSTEM

EXISTING WALL CONSTRUCTION

CONTINUOUS SEALANT AND BACKER ROD WITH WEEPS AT EVERY VERTICAL MULLION, TYPICAL

EXISTING STEEL LINTEL

ALUMINUM STOREFRONT WINDOW SYSTEM

1x PVC TRIM BOARD

SEE DETAIL A1/A-511 FOR SIMILAR NOTES

SEE DETAIL B1/A-511 FOR SIMILAR NOTES

SEE DETAIL D1/A-511 FOR SIMILAR NOTES

ALUMINUM WINDOW SYSTEM

PVC SILL TYPE - B, SEE D4/A-511

MEMBRANE FLASHING, TYPICAL AL FOUR SIDES

1 x 3 PVC TRIM BOARD

EXISTING WALL CONSTRUCTION

EXISTING WOOD STOOL AND APRON TO REMAIN

NEW SIDING AND AIR/VAPOR MEMBRANE SYSTEM, SEE SPEC., TYP

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

ALUMINUM WINDOW SYSTEM

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

EXISTING WOOD CASING TO REMAIN

PVC MOULDING TYPE - A, SEE D4/A-511

EXISTING WALL CONSTRUCTION

NEW SIDING AND AIR/VAPOR MEMBRANE SYSTEM, SEE SPEC., TYP

SEE DETAIL A4/A-511 FOR SIMILAR NOTES

SEE DETAIL B4/A-511 FOR SIMILAR NOTES

SEE DETAIL C4/A-511 FOR SIMILAR NOTES

METAL FLASHING

ALUMINUM WINDOW SYSTEM

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

EXISTING WOOD CASING TO REMAIN

PVC MOULDING TYPE - A, SEE D4/A-511

EXISTING WALL CONSTRUCTION

NEW SIDING AND AIR/VAPOR MEMBRANE SYSTEM, SEE SPEC., TYP

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

CONTINUOUS CAULKING, TYPICAL

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

CONTINUOUS CAULKING, TYPICAL

CONTINUOUS CAULKING, TYPICAL

CONTINUOUS SEALANT AND BACKER ROD WITH WEEPS AT EVERY VERTICAL MULLION, TYPICAL

CONTINUOUS CAULKING, TYPICAL

3" = 1'-0"D4

PVC MOULDING AND SILL TYPES

CONTINUOUS SEALANT AND BACKER ROD WITH WEEPS AT EVERY VERTICAL MULLION, TYPICAL

METAL SILL FLASHING

1x PVC TRIM BOARD

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

ALUMINUM RECEPTOR AT HEAD AND JAMB, TYPICAL

CONTINUOUS SEALANT AND BACKER ROD WITH WEEPS AT EVERY VERTICAL MULLION, TYPICAL

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

CONTINUOUS CAULKING, TYPICAL

MEMBRANE FLASHING, TYPICAL AL FOUR SIDES

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

1x PVC TRIM BOARD

CONTINUOUS SEALANT AND BACKER ROD WITH WEEPS AT EVERY VERTICAL MULLION, TYPICAL

ALUMINUM WINDOW SYSTEM

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

CONTINUOUS CAULKING, TYPICAL

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

PVC MOULDING TYPE - 1, SEE D5/A-511

PVC MOULDING TYPE - 1, SEE D5/A-511

NEW SIDING AND AIR/VAPOR MEMBRANE SYSTEM, SEE SPEC., TYP

NEW SIDING AND AIR/VAPOR MEMBRANE SYSTEM, SEE SPEC., TYP

METAL FLASHING

ALUMINUM WINDOW SYSTEM

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

EXISTING WOOD CASING TO REMAIN

PVC MOULDING TYPE - A, SEE D4/A-511

EXISTING WALL CONSTRUCTION

NEW SIDING AND AIR/VAPOR MEMBRANE SYSTEM, SEE SPEC., TYP

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

CONTINUOUS CAULKING, TYPICAL

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

1x PVC TRIM BOARD

1x PVC TRIM BOARD

ALUMINUM WINDOW OR STOREFRONT SYSTEM

ALUMINUM WINDOW OR STOREFRONT SYSTEM

ALUMINUM WINDOW OR STOREFRONT SYSTEM

ALUMINUM WINDOW SYSTEM

PVC SILL TYPE - B, SEE D4/A-511

MEMBRANE FLASHING, TYPICAL AL FOUR SIDES

1 x 3 PVC TRIM BOARD

EXISTING WALL CONSTRUCTION

EXISTING WOOD STOOL AND APRON TO REMAIN

NEW SIDING AND AIR/VAPOR MEMBRANE SYSTEM, SEE SPEC., TYP

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

CONTINUOUS CAULKING, TYPICAL

CONTINUOUS SEALANT AND BACKER ROD WITH WEEPS AT EVERY VERTICAL MULLION, TYPICAL

CONTINUOUS CAULKING, TYPICAL

OPERABLE SASH

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

MINERAL WOOL INSULATION, TYPICAL AT HEAD AND JAMB

SILL START, TYPICAL AT ALL SILL CONDITION SILL START, TYPICAL AT ALL SILL CONDITION

ALUMINUM RECEPTOR AT HEAD AND JAMB, TYPICAL

MINERAL WOOL INSULATION, TYPICAL AT HEAD AND JAMB

ALUMINUM RECEPTOR AT HEAD AND JAMB, TYPICAL

ALUMINUM WINDOW SYSTEM

ROLLER SHADE

ROLLER SHADE

ROLLER SHADE

EXISTING WALL CONSTRUCTION

PVC MOULDING TYPE -1, SEE D5/A-511

CONTINUOUS SEALANT AND BACKER ROD WITH WEEPS AT EVERY VERTICAL MULLION - TYPICAL

EXISTING ACOUSTIC PANEL

EXISTING STEEL LINTEL

CONTINUOUS CAULKING, TYPICAL

CONTINUOUS ALUMINUM SNAP TRIM AND CLI, TYPICAL AT SILL, JAMB AND HEAD

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

1

Page 25: HALIFAX ELEMENTARY SCHOOL

NEW WOOD STOOL & APRON

ALUMINUM WINDOW

WRAP WOOD SILL/BLOCKING WITH ALUMINUM BRAKE METAL

WOOD BLOCKING

SNAP TRIM

SEALANT

3 1

/2"

3/4

"

1/2"

PROVIDE NEW 1x WOOD SILL & APRON -PAINT

FC SIDING ON AIR/VAPOR MEMBRANE

WRAP WOOD TRIM WITH ALUMINUM BRAKE METAL

CONTINUOUS SEALANT

ALUMINUM WINDOW

PROVIDE NEW BLOCKING

CONTINUOUS SNAP TRIM

CONTINUOUS CAULKING

EXISTING WOOD TRIM

PROVIDE NEW 1x WOOD CASING AND STOPS - PAINT

FC SIDING ON AIR/VAPOR MEMBRANE

WRAP WOOD TRIM WITH ALUMINUM BRAKE METAL

CONTINUOUS SEALANT

ALUMINUM WINDOW

PROVIDE NEW BLOCKING

CONTINUOUS SNAP TRIM

CONTINUOUS CAULKING

ROLLER SHADE

MINERAL WOOD INSULATION

EXISTING WOOD TRIM

NEW WOOD CASING

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

3" = 1'-0"

1/2

3/2

018

11:1

2:5

5 A

M

A-512

WINDOW &STOREFRONT

DETAILS

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

3" = 1'-0"A2

SILL @ GYM ENTRANCE

3" = 1'-0"B2

JAMB @ GYM ENTRANCE

3" = 1'-0"C2

JAMB POST @ GYM ENTRANCE

3" = 1'-0"D2

HEAD @ GYM ENTRANCE

3" = 1'-0"C1

SILL @ MAIN ENTRANCE

3" = 1'-0"D1

HEAD @ MAIN ENTRANCE

3" = 1'-0"A3

HEAD @ CORRIDOR

3" = 1'-0"B3

JAMB POST @ CORRIDOR - WING C

3" = 1'-0"C3

JAMB POST @ MEDIA CENTER

3" = 1'-0"D3

HEADER / TRANSOM

SEE DETAIL A4/A-511 FOR SIMILAR NOTES

SEE DETAIL C4/A-511 FOR SIMILAR NOTES

SEE DETAIL A4/A-511 FOR SIMILAR NOTES

SEE DETAIL C4/A-511 FOR SIMILAR NOTES

SEE DETAIL C4/A-511 FOR SIMILAR NOTES

PVC SILL TYPE - A, SEE D4/A-511

ALUMINUM STOREFRONT SYSTEM

EXISTING WALL CONSTRUCTION

EXISTING WOOD CASING TO REMAIN

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

ALUMINUM STOREFRONT SYSTEM

ALUMINUM STOREFRONT SYSTEM

EXISTING WOOD POST

METAL CLOSURE, COLOR TO MATCH WINDOW FRAME

CONTINUOUS CAULKING, TYPICAL

EXISTING WOOD CASING TO REMAIN

ALUMINUM DOOR WITH STOREFRONT FRAME

ALUMINUM STOREFRONT SYSTEM

EXISTING WOOD POST

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

CONTINUOUS CAULKING, TYPICAL

1X PVC TRIM BOARD

ALUMINUM STOREFRONT SYSTEM

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

EXISTING STEEL TUBE COLUMN

1x PVC TRIM BOARD

CONTINUOUS CAULKING, TYPICAL

EXISTING WOOD CASING TO REMAIN

EXISTING STEEL BEAM

EXISTING CEILING TO REMAIN

PVC MOULDING TYPE - A, SEE D4/A-511

1 x PVC TRIM BOARD

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

CONTINUOUS CAULKING, TYPICAL

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

CONTINUOUS CAULKING, TYPICAL

TRIM BOARD, PAINTED TO MATCH ADJACENT

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

EXISTING WOOD CASING TO REMAIN

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

ALUMINUM STOREFRONT SYSTEM

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

CONTINUOUS CAULKING, TYPICAL

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

1x PVC TRIM BOARD

P.T. CONTINUOUS WOOD BLOCKING

SEE DETAIL C3/A-512 FOR SIMILAR NOTES

PVC BEADBOARD

PVC BEADBOARD

ALUMINUM STOREFRONT SYSTEM

ALUMINUM STOREFRONT SYSTEM

EXISTING STRUCTURE

PVC PANELS

ALUMINUM STOREFRONT SYSTEM

PVC SILL TYPE - B, SEE D4/A-511

MEMBRANE FLASHING, TYPICAL AL FOUR SIDES

EXISTING WALL CONSTRUCTION

EXISTING WOOD STOOL AND APRON TO REMAIN

CONTINUOUS SEALANT AND BACKER ROD WITH WEEPS AT EVERY VERTICAL MULLION, TYPICAL

EXISTING WOOD CASING

EXISTING STRUCTURAL TUBE

CONTINUOUS CAULKING, TYPICAL

ALUMINUM STOREFRONT SYSTEM

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

1x PVC TRIM BOARD

CONTINUOUS CAULKING, TYPICAL

ALUMINUM STOREFRONT SYSTEM

3" = 1'-0"A4

WINDOW SILL @ WING B - OLD

3" = 1'-0"B4

WINDOW JAMB @ WING B - OLD

3" = 1'-0"C4

WINDOW HEAD @ WING B - OLD

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

NEW WOOD CASING

1

1

1

1

1

Page 26: HALIFAX ELEMENTARY SCHOOL

W

1/2

W

COMPRESSED

BACKER ROD

CONCAVE

TOOL SEALANT

BACK SIDE OF SELF-ADHERING MEMBRANE

PAN - SEAL ALL CORNERS, AND JOINTS TO

PROVIDE WATERTIGHT SEAL.

JAMB SIDE OF SELF-ADHERING MEMBRANE

PAN - TYPICAL EACH SIDE OF WINDOW

OPENING.

SELF-ADHERING MEMBRANE PAN SILL

FLASHING

P.T. WOOD BLOCKING

WINDOW SILL

BRICK OR LAP SIDING

PROVIDE NEW WOOD BLOCKING

EXISTING WOOD FRAME

LINE OF WINDOW SILL BELOW

SEALANT

1X PVC TRIM WITH MITERED CORNERS

LINE OF STOOL BELOW

PROVIDE NEW WOOD CASING - PAINT

PROVIDE NEW WOOD BLOCKING

SNAP TRIM

ALUMINUM WINDOW

1/2"1/2"

1/2" PVC PANEL

AIR/VAPOR BARRIER

ALUMINUM BRAKE CLOSURE TRIM

EXISTING FOUNDATION WALL

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

As indicated

1/2

3/2

018

11:1

2:5

7 A

M

A-513

WINDOW DETAILS

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

3" = 1'-0"C4

COURTYARD HEAD DETAIL

3" = 1'-0"A4

COURTYARD SILL DETAIL

3" = 1'-0"B4

COURTYARD JAMB DETAIL

3" = 1'-0"A3

JAMB DETAIL @ KINDERGARTEN

3" = 1'-0"B3

COURTYARD JAMB POST DETAIL

3" = 1'-0"A1

SILL FLASHING DETAIL

ALUMINUM WINDOW SYSTEM

1"x4" PVC APRON (SLOPE TOP)

MEMBRANE FLASHING, TYPICAL AL FOUR SIDES

1/2" PVC PANELEXISTING WALL CONSTRUCTION

NEW WOOD STOOL AND APRON

EXISTING WOOD TRIM

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

PROVIDE WOOD BLOCKING

CONTINUOUS SEALANT AND BACKER ROD WITH WEEPS AT EVERY VERTICAL MULLION, TYPICAL

CONTINUOUS CAULKING, TYPICAL

ORIGINAL WINDOW FRAME

AIR/VAPOR MEMBRANE

1x PVC CLOSURE TRIM

ALUMINUM BRAKE CLOSURE TRIM OVER EXISTING WOOD TRIM

LINE OF GRADE

ALUMINUM SILL FLASHING

EXISTING SHEATHING

PVC 1X TRIM

MEMBRANE FLASHING

AWNING WINDOW SYSTEM

EXISTING WOOD CASING

EXISTING WOOD CASING

EXISTING NARROW DOOR FRAME

ALUMINUM WINDOW SYSTEM

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

EXISTING WOOD CASING TO REMAIN

1"x4" PVC TRIM

EXISTING WALL CONSTRUCTION NEW SIDING AND VAPOR BARRIER SYSTEM, SEE SPEC., TYP

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

CONTINUOUS CAULKING, TYPICAL

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

EXISTING SHEATHING

1x PVC CLOSURE TRIM AND WOOD BLOCKING

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

P.T. CONTINUOUS WOOD BLOCKING

NEW WOOD CASING

EXISTING WOOD POST

CONTINUOUS CAULKING, TYPICAL

ALUMINUM WINDOW SYSTEM

CONTINUOUS CAULKING, TYPICAL

ALUMINUM WINDOW SYSTEM

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

1" x PVC TRIM BOARD

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

ALUMINUM WINDOW SYSTEM CONTINUOUS

ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

1"x4" PVC TRIM AND WOOD BLOCKING (SLOPE TOP)

EXISTING WALL CONSTRUCTION

1"x4" PVC TRIM AND WOOD BLOCKING

CONTINUOUS SEALANT AND BACKER ROD ON BOTH SIDES, TYPICAL

CONTINUOUS CAULKING, TYPICAL

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

ROLL-DOWN SHADE, TYPICAL

1/2" PVC PANEL

VAPOR BARRIER SYSTEM, SEE SPEC., TYP

CONTINUOUS ALUMINUM DRIP FLASHING

3" = 1'-0"B2

WINDOW SILL @ ART/MUSIC

ALUMINUM WINDOW SYSTEM

CONTINUOUS CAULKING, TYPICAL

MEMBRANE FLASHING, TYPICAL ALL FOUR SIDES

EXISTING WALL CONSTRUCTION

EXISTING WOOD TRIM

CONTINUOUS ALUMINUM SNAP TRIM AND CLIP, TYPICAL AT SILL, JAMB, AND HEAD.

PROVIDE NEW 1/2" PVC PANEL

CONTINUOUS SEALANT AND BACKER ROD WITH WEEPS AT EVERY VERTICAL MULLION, TYPICAL

PROVIDE 3/4" HARDWOOD STOOL AND APRON - PAINTED

AIR/VAPOR MEMBRANE

ALUMINUM BRAKE CLOSURE TRIM OVER EXISTING WOOD TRIM

LINE OF GRADE

EXISTING SHEATHING

WOOD BLOCKING

WRAP EXISTING WOOD SILL / BLOCKING IN ALUMINUM BRAKE METAL

ALUMINUM RECEPTOR AT HEAD AND JAMB, TYPICAL

SILL START, TYPICAL

3" = 1'-0"C2

WINDOW JAMB

6" = 1'-0"B1

METAL CLOSURE TRIM DETAIL

B1

A-513

REFER TO DETAIL B1/A-513 FOR METAL CLOSURE TRIM

REFER TO DETAIL B1/A-513 FOR METAL CLOSURE TRIM

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

NEW WOOD CASING

1

1

1

1

EXISTING WOOD BLOCKING

Page 27: HALIFAX ELEMENTARY SCHOOL

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

3" = 1'-0"

1/2

3/2

018

11:1

2:5

9 A

M

A-521

DOOR DETAILS

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

3" = 1'-0"D1

HEAD DETAIL AT GARAGE

3" = 1'-0"A2

DOOR SILL

3" = 1'-0"B1

JAMB DETAIL AT OVERHEAD DOOR

3" = 1'-0"A1

JAMB DETAIL AT GARAGE

3" = 1'-0"C1

HEAD DETAIL AT OVERHEAD DOOR

EXISTING CMU WALL CONSTRUCTION

OVERHEAD DOOR AND TRACK

MEMBRANE FLASHING

1x PVC TRIMBOARD

PROVIDE WOOD BLOCKING

OVERHEAD DOOR AND TRACK

MEMBRANE FLASHING

1x PVC TRIMBOARD

1x5 PVC TRIMBOARD

PVC MOULDING TYPE -1

FC SIDING

OVERHEAD DOOR AND TRACK

MEMBRANE FLASHING

1x PVC RETURN TRIMBOARD

1x5 PVC TRIMBOARD

PVC MOULDING TYPE -1

METAL FLASHING

AIR/VAPOR BARRIER

EXISTING HM NARROW FRAME

MEMBRANE FLASHING

1x PVC RETURN TRIMBOARD

PVC MOULDING TYPE -1

AIR/VAPOR BARRIER

1x5 PVC TRIMBOARD

METAL FLASHING

EXISTING CMU WALL CONSTRUCTION

EXISTING CMU WALL CONSTRUCTION

FC SIDING

FC SIDING

ALUMINUM THRESHOLD SET IN GROUT

ALUMINUM DOOR

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 28: HALIFAX ELEMENTARY SCHOOL

EXISTING METAL RAKEFLASHING TO REMAIN

EXISTING METAL RAKEFLASHING OVER RAKE BOARDTO REMAIN

EXISTING BRAKE METAL ATUNDERSIDE OF EXISTINGSOFFIT BOARD TO REMAIN

EXISTING ALUMINUMGUTTER WITHHANGER STRAPS TOREMAIN

EXISTING CONSTRUCTION TOREMAIN

EXISTING CONTINUOUS METALRAKE FLASHING TO REMAIN

EXISTING METAL RAKEFLASHING OVER RAKE BOARDTO REMAIN

EXISTING BRAKE METAL ATUNDERSIDE OF EXISTING RAKEBOARD TO REMAIN

EXISTING CONSTRUCTION TOREMAIN

REMOVE AND REINSTALLEXISTING ALUMINUMRAINWATER LEADER ASREQUIRED TO INSTALLNEW WORK

EXISTING ALUMINUMGUTTER WITHHANGER STRAPS TOREMAIN

EXISTING METAL FASCIAOVER EXISTING WOODFASCIA BOARD

EXISTING BRAKE METALWITHCONCEALED FASTENERSAT UNDERSIDE OFEXISTING SOFFIT BOARDAND VENT OPENING TOREMAIN

PVC TRIM

REMOVE ANDREINSTALL EXISTINGALUMINUM RAINWATERLEADER, AS REQUIREDTO INSTALL NEW WORK

EXISTING CORNICECONSTRUCTION TOREMAIN - SCRAPE ANDPAINT

EXISTING ALUMINUMGUTTER WITHHANGER STRAPS TOREMAIN

EXISTING WOOD TRIMTO REMAIN

REMOVE AND REINSTALLEXISTING ALUMINUMRAINWATER LEADER ASREQUIRED TO INSTALL NEWWORK

EXISTING ALUMINUM GUTTERWITH HANGER STRAPS TOREMAIN

SLOPE

EXISTING METAL FASCIA OVEREXISTING WOOD FASCIABOARD TO REMAIN

EXISTING BRAKE METAL WITHCONCEALED FASTENERSAT UNDERSIDE OF EXISTINGSOFFIT BOARD TO REMAIN

CEMENTITIOUS SIDING OVERAIR BARRIER

REMOVE GLASS AND EXTERIOR STOPS

REMOVE COVE MOLDING

EXISTING CONSTRUCTION TO REMAIN

EXISTING CORNICE CONSTRUCTION TO REMAIN (PAINT)

REMOVE SASH AND WOOD STOP

EXISTING FRAME CASINGS TO REMAIN

EXISTING CORNICE CONSTRUCTION TO REMAIN (PAINT)

EXISTING CONSTRUCTION TO REMAIN

FC SIDING OVER AIR BARRIER

1 X 4 PVC TRIM

FC SIDING OVER AIR BARRIER

(1 X 4)

FC SIDING OVER AIR BARRIER

FC SIDING OVER AIR BARRIER

(AT FLAT ROOF CLASSROOMS & OFFICES FACING COURTYARD)

1 x 4 PVC TRIM

EQ

EQ

1 1/2"1'-5"

1 1/2"

1 1

/2"

1'-5

"

1 1

/2"

5/4" X 2 PVC TRIMBOARDS WITH MITERED CORNERS

3/4" PVC PANEL

EXISTING GYPSUM BOARD

EXISTING WALL CONSTRUCTION

EXISTING SHEATHING

1/2" PVC PANEL

CONTINUOUS AIR/VAPOR MEMBRANE

1" x PVC TRIM WITH MITERED CORNERS

WOOD BLOCKING

EXISTING WOOD FRAME

LINE OF WINDOW SILL ABOVE

1/2"

3 1

/2"

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

As indicated

1/2

3/2

018

11:1

3:0

0 A

M

A-531

MISC DETAILS

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

3" = 1'-0"B1

HEAD DETAIL-WDO TYPE "V" - NEW 3" = 1'-0"

B2HEAD DETAIL-WDO TYPE "X" - NEW

3" = 1'-0"B3

RAKE DETAIL 1 - NEW 3" = 1'-0"

B4RAKE DETAIL 2 - NEW

3" = 1'-0"A1

EAVE GUTTER AT SHINGLE ROOF DETAIL 1 - NEW 3" = 1'-0"

A2EAVE GUTTER AT SHINGLE ROOF DETAIL 2 - NEW

3" = 1'-0"A3

EAVE GUTTER DETAIL AT FLAT ROOF - NEW

1 1/2" = 1'-0"D3

LIGHT SCONCE PANEL DETAIL 3" = 1'-0"

D4ART/MUSIC PANEL DETAIL

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

Page 29: HALIFAX ELEMENTARY SCHOOL

1X6 PVC TRIM (CORNERBOARD)

5 1/2"

6"

3/4" X 3/4" INSIDE CORNER TYPICAL @ INSIDE CORNERS

EXISTING STONE VENEER WALL BELOW

FC SIDING

AIR BARRIER

5/4X6 PVC TRIM (CORNERBOARD)MITERED CORNER

FC SIDING

AIR/VAPOR BARRIER

5/4X6 PVC TRIM (CORNERBOARD) MITERED CORNER

6"

5 1/2"

5/4X6 PVC TRIM (CORNERBOARD)

1X12 PVC TRIM

5/4X6 PVC TRIM

FC SIDING

PVC MOLDING

11

1/4

"

5 1/2"MITERED CORNER TYP.

AIR/VAPOR BARRIER

1X12 PVC TRIM

1X4 PVC TRIM

11

1/4

"

11 1/4" 2"

5/4X12 PVC TRIM

1/4 P.T. WD. BLOCKING

11

1/4

"

FC OR PVC PANEL (3/8")

PVC MOLDING

PVC PANEL MOLDING

1X12 PVC TRIM

1X4 PVC TRIM

PVC MOLDING

1X4 PVC TRIM

1X PVC TRIM

SEALANT

1X PVC TRIM

1X4 PVC TRIM

MITERED CORNER

2"

PVC PANELS

OUTSIDE F.O. BLDG

3'-0"

2'-8

"9

"8

"3

'-0

"8

"2

'-0

"

EQ EQ5"

NOTE: MITER ALL PVC CORNERS

PVC BASE CAP MOULDING AT PANEL PERIMETER

1X PVC TRIM BOARDS

1'-4

"6

"3

'-1

"8

"2

'-0

"9

"

EQ

2'-0" 5"

EQ

PVC PANELS

± 81.6'MAIN LEVEL

OUTSIDE F.O. BLDG

PVC BASE CAP MOULDING AT PANEL PERIMETER

1X PVC TRIM BOARDS

NOTE: MITER ALL PVC CORNERS

T.O. FIN GRADE

1X6 PVC TRIMWATER TABLE

CEMENTITIOUS STARTER STRIP

PRE FINISHED ALUM. FLASH W/DRIP

FC SIDING

AIR/VAPOR BARRIER

TAPE

1/2

"

8"

B.O

. W

D T

RIM

TO

T

.O. F

IN. G

RA

DE

SE

E D

WG

S

1X6 PVC TRIMWATER TABLE

CEMENTITIOUS STARTER STRIP

PRE FINISHED ALUM. FLASH W/DRIP

FC SIDING

AIR/VAPOR BARRIER

TAPE

MIN

1/2

"

1X PVC TRIM

AIR/VAPOR BARRIER

1X PVC TRIM

FC SIDING

.020 PRE FIN ALUMINUM FLASH

SET UNIT VENTILLATOR GRILL IN SEALANT

1X5 PVC TRIM

PVC SILL

NEW WOOD SILL & APRON

ALUMINIUM FLASHING WITH DRIP

CEMENTITIOUS STARTER STRIP

FC SIDING

AIR/VAPOR BARRIER

1X6 PVC TRIM

TAPE

1"

1X3 PVC TRIM WITH RABBET CUT FOR BEADBOARD

BEADBOARD ON AIR/VAPOR BARRIER

FIN GRADE SEE DWGS

8"

ALIG

N T

OP

OF

TR

IM

W/B

.O. W

IND

OW

SIL

L

1X PVC TRIM

ALUMINIUM FLASHING W/ DRIP

1X4 P.T. BLOCKING

1X4 P.T. BLOCKING

1X PVC TRIM

CEMENTITIOUS STARTER STRIP

PRE FINISHED ALUM. FLASH W/DRIP

4"

4"

1/2

"1

/2"

MIN

FC SIDING

FC SIDING

AIR/VAPOR BARRIER

TAPE

± 2

'-7"

AF

F

SEALANT

5/4X12 PVC TRIM(CORNERBOARD)

FC SIDING

AIR/VAPOR BARRIER

11 1/4" MITERED CORNER

11 1/4"5/4X12 PVC TRIM

EXISTING WOOD BLOCKING

EXISTING STEEL TUBE

MATCH EXISTING

FC SIDING

AIR/VAPOR BARRIER

5/4X6 PVC TRIM(CORNERBOARD)

FC SIDING

AIR/VAPOR BARRIER

MITERED CORNER

FC SIDING

.020 PRE FIN ALUMINUM FLASH W/DRIP

1X PVC TRIM

FC SIDING

1X PVC TRIM

.020 PRE FIN ALUMINUM FLASH

SET UNIT VENTILLATOR GRILL IN SEALANT

.040 ALUMINUM FLASH W/DRIP

TERMITE SHIELD

EXISTING STONE VENEER

SEALANT

SLOPE

AIR/VAPOR BARRIER

FC SIDING

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

As indicated

1/2

3/2

018

11:1

3:0

4 A

M

A-541

WALL DETAILS

1614.03

12/13/17

Author

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1 1/2" = 1'-0"D1

FIELDSTONE VENEER CORNER DETAIL

1 1/2" = 1'-0"C1

CLAPBOARD TO CLAPBOARD CORNER BOARD DETAIL

1 1/2" = 1'-0"B1

OUTSIDE CORNER ENTRY TO LOBBY DETAIL

1 1/2" = 1'-0"A1

GYM ENTRANCE ALCOVE DETAIL 1/4" = 1'-0"

A2LOBBY 106 ENTRANCE ALCOVE DETAIL

1/4" = 1'-0"A3

MAIN LOBBY ENTRANCE ALCOVE DETAIL 3" = 1'-0"

A4WATER TABLE DETAIL @ GYM

3" = 1'-0"B4

WATER TABLE DETAIL 3" = 1'-0"

B2UNIT VENTILLATOR GRILL DETAIL 2

3" = 1'-0"B3

SOFFIT CONDITION @ WING C CLASSROOM

3" = 1'-0"D3

MDO PANEL @ EXTERIOR CLAPBOARD WALL

1 1/2" = 1'-0"C3

BRICK TO CLAPBOARD OUTSIDE CORNER @ GYM

3" = 1'-0"D4

PILASTER DETAIL

1 1/2" = 1'-0"C4

CLAPBOARD TO CLAPBOARD OUTSIDE CORNER @ GYM 3" = 1'-0"

C2UNIT VENTILLATOR GRILL DETAIL 1

3" = 1'-0"D2

FIELDSTONE VENEER SECTION DETAIL

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

11

2/2

1/1

7A

DD

EN

DU

M 1

1

Page 30: HALIFAX ELEMENTARY SCHOOL

A-551

2

A-551

3

A-551

5

A-551

6

A-551

7

A-551

9

A-551

8

A-551

10

A-551

12A-551

11

A-551

4

A-551

1

A-551

9Sim

A-551

10Sim

A-551

8Sim

A-551

8Sim

A-551

8Sim

A-551

7Sim

A-551

13

N.I.C

1X3 PVC TRIM BOARD

PVC BEADBOARD

1X3 PVC TRIM

PVC BEADBOARD

EXISTING SOFFIT VENTS TO REMAIN

EXISTING LIGHT FIXTURE TO REMAINSEE NOTE 1

1X3 PVC TRIM BOARD

PVC BEADBOARD

EXISTING LIGHT FIXTURESEE NOTE 1

1X3 PVC TRIM BOARDPVC BEADBOARD

PVC BEADBOARD - TYPICAL

EXISTING LIGHTING FIXTURES - SEE NOTE 1

1X3 PVC TRIM BOARD

1X3 PVC TRIM BOARD

PVC BEADBOARD

1X3 PVC TRIM BOARD

PVC BEADBOARD

SCRAPE & PAINT EXISTING SOFFIT

SCRAPE & PAINT EXISTING SOFFIT

PVC BEADBOARD

1X3 PVC TRIM BOARD

PVC BEADBOARD

1X3 PVC TRIM BOARD

1X3 PVC TRIM BOARD

PVC BEADBOARD

1X3 PVC TRIM BOARD

PVC BEADBOARD

HA

BE

EB

AR

CH

IT

EC

TS

AS

SO

CIA

TE

S&

15

0 L

ON

GW

AT

ER

DR

NO

RW

EL

L,

MA

02

06

1-1

61

8O

FF

ICE

: 7

81

.87

1.9

80

4F

AX

: 7

8.8

71

.98

05

ha

be

eb

arc

h.c

om

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

1

A

1 2 3 4 5

B

C

D

2 3 4 5

CONSULTANT

NORTH ARROW

KEY PLAN

STAMP

MS

BA

AC

CE

LE

RA

TE

D R

EP

AIR

PR

OG

RA

MW

IND

OW

S,

DO

OR

S &

SID

ING

RE

PL

AC

EM

EN

T

As indicated

1/2

3/2

018

11:1

3:1

2 A

M

A-551

REFLECTEDSOFFIT PLAN

1614.03

12/13/17

gw

Checker

464 P

LY

MO

UT

H S

TR

EE

T H

AL

IFA

X, M

A, 02338

HA

LIF

AX

EL

EM

EN

TA

RY

SC

HO

OL

1/16" = 1'-0"C1

REFLECTED SOFFIT PLAN

1/8" = 1'-0"2

SOFFIT - 2 1/8" = 1'-0"

3SOFFIT - 3

1/8" = 1'-0"4

SOFFIT - 4 1/8" = 1'-0"

5SOFFIT - 5

1/8" = 1'-0"6

SOFFIT - 6

1/8" = 1'-0"7

SOFFIT - 7 1/8" = 1'-0"

8SOFFIT - 8

1/8" = 1'-0"9

SOFFIT - 9 1/8" = 1'-0"

10SOFFIT - 10

1/8" = 1'-0"11

SOFFIT - 11 1/8" = 1'-0"

12SOFFIT - 12

1/8" = 1'-0"1

SOFFIT - 1

1/8" = 1'-0"13

SOFFIT - 13

NOTES:1. REMOVE EXISTING LIGHT FIXTURE

AND RESET AFTER BEADBOARD INSTALLATION.

2. REFER TO SECTION B3 ON DRAWING A-541 FOR SOFFIT DETAIL.

RE

VIS

ION

MA

RK

DA

TE

RE

VIS

ION

S

12

/13/1

7C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S