COMPANY OVERVIEW Hanil Science Industrial Co., Ltd. is one of the leading corporation of scientific and laboratory equipment to research institutes, educational institution, testing,clinical laboratories and so on. The company has a consistent track record of sales in biotechnology, medical, agriculture, life sciences, microbiology, etc in korea. We have over 60 percentage of market share in Korea and put the first step into overseas market early 2011. Hanil has been trying to research and develop the new models regulary and offer the best after sales service for customer’s satisfaction. At Hanil, it remains a constant endeavor to provide our customers with : - High-quality & durable products - Easy-to-use, user-serviceable equipment - Built-in safety features - ISO 9001 certified - KGMP certified Hanil offers highest quality laboratory instrument to the science community from research to industry. Our business staff, having years of experience, help customers in selecting products, most suited for their Applications. Hanil is providing installation, warranty and after warranty service. And our technical service team provides the prompt service throughout Korea & overseas.

Upload: others

Post on 16-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • COMPANY OVERVIEWHanil Science Industrial Co., Ltd. is one of the leading corporation of scientific and laboratoryequipment to research institutes, educational institution, testing,clinical laboratories and so on.The company has a consistent track record of sales in biotechnology, medical, agriculture, lifesciences, microbiology, etc in korea.We have over 60 percentage of market share in Korea and put the first step into overseas market early 2011.Hanil has been trying to research and develop the new models regulary and offer the best after salesservice for customer’s satisfaction.

    At Hanil, it remains a constant endeavor to provide our customers with :- High-quality & durable products- Easy-to-use, user-serviceable equipment- Built-in safety features- ISO 9001 certified- KGMP certified

    Hanil offers highest quality laboratory instrument to the science community from research to industry.Our business staff, having years of experience, help customers in selecting products, most suited for theirApplications.Hanil is providing installation, warranty and after warranty service.And our technical service team provides the prompt servicethroughout Korea & overseas.��������

  • Hanil Gangneung Factory was constructed from December in 2008 to July in2010. It covers an area of 10,839m2 and construction area of 4,832m2 scale.It produces over 100,000 units of output on annual maximum. Hanil Gangneung Factory is designed not only for manufacturing but alsoequipped hospitality service such as guest house for the buyers and users forvisiting or education. The factory is built in beautiful nature in Gangneungprovince.

    Edge of premium expert withadvanced technology

  • Cutting edge NCT and auto cutting & bendingmacine can produce bulk metal sheet productsand decrease allowance of cutting & bendingto make precise shapings.

    Metal Plate Line

    Automation assembly line which is 180m intotal length consists of 4 assembly lines and allprocess is automatized and standaradized toproduce from semi-manufactured goods tofinished products.

    Automation Assembly Line

    3 units of high-tech machining centers, 6 unitsof CNC, total 9 automation lines are equippedto manufacture precise processing partsincluding rotors, rotating shafts, and fittings offermentors.

    Automation Process Line

  • Know-how for 50years, the best technology certificated

    Documentation in GMP

    Our products are qualified in global standard and GMP requirement.We offer all concerned documents for validation in accordance with GMP requirement.

    Documentation- Installation Qualification- Operational Qualification- Details of Qualification- Operation / Maintenance manual- Certificates of calibration for all test equipment- Vendor QC report

    Safety

    �Triple door for user’s safety if rotating rotor cannot work. (certified CE mark, proven safety throughbraking test)

    �Safety lid-lock function that makes it never open in the middle of motion, and it is certified byrepetitive braking test.

    �Minimize the risk from unexpected door shutting with Lid-drop protection function.

    �Maintaining the degree of the door auto-opening for safety.

    �If work is stopped by sudden black-out or any irresistible factors, it is able to correct immediately bytaking out the sample.

    �Prevent samples and experimenters from contamination or infection by autoclave and corrosion-freerotor.

    �When electronic over current happens : you can break current with fuse and ground eachconnection for safety of user’s electronic risk.

    Motor

    �High torque AC Induction motor and BLDC motor : no brush, eco-friendly process without carbondust, extend equipment’s life, maintaining low noise and high safety condition.

    Techniques

    �Motor : Motor driving system technology optimized by each rotation space.

    �Vacuum : Vacuum and ceiling technique to eliminate friction with air when high-speed rotation.

    �Balance : Balance correcting technique which does not allow error within 0.1g balance of rotation.

    �Control technique : Full Digital Micom Processor is available for maintaining precise RPM replay inhigh-speed rotation.

    ISO9001:2008

    Medical EquipmentKGMP

    Europe Electicity SafetyCertification

    INNO-BIZ

    invention patent

  • Micro CentrifugeSmart R17 I Smart 15 I Micro 12 I Micro 6 Mic

    ro C

    entr

    ifuge

  • Mic

    ro C

    entri

    fuge

    08

    Inventive 2way radiator for maintainingrefrigeration temperature for long term and fastcorrection.

    Want fast temperature correction?

    Quick acceleration and deceleration helpsspeedy test process and special rubber hubattached rotor absorbs vibration to keep perfectrepeatability.

    Want quick acceleration and deceleration?

    Elegant design, quick accelerations & decelerationand qualified to the best in safety, durability, andconvenience.

    Smart

    choice for Lab

    Smart R17

    Micro Centrifuge

    -10�C to+40�C

    17,000 23,005 1.5/2.0mlX 24

    Refrigerated Micro Centrifuge

    Features�Co-using Angle Rotors (A1.5/2.0mlx24) & PCR Strip rotor (0.2mlx32)�Ergonomically arranged and designed�Memory function�Speedy acceleration 15secs & deceleration 15secs (15,000 rpm)�5 steps for acceleration and deceleration can be selected for delicate liquid

    experiment�2 way-types of freezing radiator�Efficient BLDC Motor(400W) - Brushless motor provides maintenance free

    operation�Fast Cooling�Detecting over speed, over heat, system error and door opening�Patented compressor technology reduces vibrations and protects your sample�Exceptionally quiet operation, with or without rotor lid�Easy-to-read interface displays both speed (rpm) and force (rcf)�Easy-to-use knobs

    Simple and elegant displaypanel

    A1.5/2.0M-24 A1.5/2.0M-18 A1.5MP-24Snap-on polypropylene rotor lid

    Description Specification Remarks

    RPM / RCF

    Max. capacity

    Time

    Temp

    Display

    Motor

    Accel/Decel

    Rotor

    Dimension

    Weight, Kg

    17,000 / 23,005xg15,000 / 21,055xg

    1.5/2.0ml x 24

    99min 59sec

    -10 �C ~ 40 �C

    Rpm, Rcf, Time, Temperature,Acc/dec, Rotor number, Prog

    BLDC/400W

    5 step(accel:15 sec. decel:15 sec.)

    Fixed Angle 1.5/2.0ml x 18Fixed Angle 1.5/2.0ml x 24

    PCR Rotor 0.2ml x 32

    295W x 553D x 282H/mm

    30Kg

    1.5/2.0ml x 181.5/2.0ml x 24

    Pulse cycle modeContinuous run,

    In 15,000rpm

    Optimized inside chamber foreffective cool-down

    �Please note that technical specifications subject to change.

  • Mic

    ro C

    entr

    ifuge

    Smart 1515,000 21,055 1.5/2.0mlX 24

    New design and technology for speedy acceleration anddeceleration. Optimized safety and convenience.

    HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    09

    Worried about temperature?

    Air Cooling Micro Centrifuge

    Description Specification Remarks

    RPM / RCF

    Max. capacity

    Time

    Display

    Motor

    Accel/Decel

    Rotor

    Dimension

    Weight, Kg

    15,000 / 21,055xg

    1.5/2.0ml x 24

    99min 59sec

    RPM, RCF, Time, Prog.

    BLDC/400W

    Accel 15 sec. / Decel 15 sec.

    Fixed Angle 1.5/2.0ml x 18Fixed Angle 1.5/2.0ml x 24

    PCR Rotor 0.2ml x 32

    293W x 380D x 242H/mm

    15Kg

    A1.5/2.0ml x 24

    Pulse cycle modeContinuous run,

    In 15,000rpm

    Quick acceleration and deceleration helpsspeedy test process and special rubber hubattached rotor absorbs vibration to keep perfectrepeatability.

    Want quick acceleration and deceleration?

    Simple and elegant displaypanel

    Effective emitting heat caused by rotor rotationand motor case through the air flow fromunder the main frame.

    Features �Co-using Angle Rotors (A1.5/2.0mlx24) & PCR Strip rotor (0.2mlx32)�Ergonomically arranged and designed�Memory for saving experiment condition [10 memories]�Speedy acceleration and deceleration (accel 15 sec, deccel 15sec / Max.

    15,000 rpm)�Efficient BLDC Motor(400W) - Brushless motor provides maintenance free

    operation)�Fast Cooling�Detecting imbalance�Applied stainless steel chamber to reduce rotational friction heat

    �Please note that technical specifications subject to change.

    A1.5/2.0M-24 A1.5/2.0M-18 A1.5MP-24Snap-on polypropylene rotor lid

  • Mic

    ro C

    entri

    fuge

    10

    Smart R17 Smart 15

    Control Display�The tiny LCD graphically displays rpm, rcf, Accel./Decel., door

    opening�Customized key pad (Easy operation and correction)�RPM/RCF auto calculation�Memory for saving experiment condition [10 memories]�Simple and elegant black display panel�Simple key button for convenience

    Safety�Detecting over speed, over heat, system error and door opening�Door lock, emergency lid lock release�Imbalance recognition�Automatic alarming system

  • Mic

    ro C

    entr

    ifuge

    HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    11

    Angle Rotors

    A1.5M-24 Rotor ID : 2

    Type

    Max. RPM

    Max. RCF

    Radius

    Dim. �/H

    Angle Rotor �45°C15,000 rpm

    21,055 x g

    83.7mm

    �172 x 38.5mm

    Tube Capacity (ml)

    Dimensions � x L mm

    Tube Type

    0.2

    6 x 18

    0.5

    8 x 30

    1.5

    11 x 38

    2.0

    11 x 38

    15,848

    63

    6 x 21

    Black

    18,112

    72

    8 x 37

    Black

    11 x 37.5

    -

    11 x 37.5

    -

    16,284

    50.4

    6 x 21

    Black

    19,289

    59.7

    8 x 37

    Black

    11 x 37.5

    -

    11 x 37.5

    -

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    24

    21.055

    83.7

    11 x 45

    A0.2M-32 Rotor ID : 3

    Type

    Max. RPM

    Max. RCF

    Radius

    Dim. �/H

    Angle Rotor �45°C12,500 rpm

    9,695 x g

    55.5mm

    �172 x 38.5mm

    Tube Capacity (ml)

    Dimensions � x L mm

    Tube Type

    0.2

    6 x 8

    0.2

    -

    48 4-tube Strips

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    9.695

    55.5

    6.5 x 17

    A1.5M-18 Rotor ID : 1

    Type

    Max. RPM

    Max. RCF

    Radius

    Dim. �/H

    Angle Rotor �45°C17,000 rpm

    23,005 x g

    71.2mm

    �147 x 38.5mm

    Tube Capacity (ml)

    Dimensions � x L mm

    Tube Type

    0.2

    6 x 18

    0.5

    8 x 30

    1.5

    11 x 38

    2.0

    11 x 38

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    18

    23.005

    71.2

    11 x 45

  • Mic

    ro C

    entri

    fuge

    12

    RPM can be changeable by RPM knob duringoperation.Timer can be set from 0 to 15 min.

    Easy-to-use control knob of RPM/Timer

    MAX. RPM 6,000MAX. CAP 32 x0.2ml

    PCR Strip rotor (option)

    Start for every experiment!Hanil’s best product, Micro 12, personal centrifuge whichcertified its quality for 50 years. Came back with compactdesign and upgraded spec!

    Personal Centrifuge

    Micro 12

    Micro Centrifuge

    13,500 12,032 1.5/2.0mlX 12

    Features �Co-using Angle & PCR rotor�Spin down (Pulse) function�Speedy acceleration 15secs & deceleration 15secs �Efficient BLDC Motor(65W) - Brushless motor provides maintenance free

    operation�Electro sensitive non-contacting door sensor�Avoidance of contamination by carbon powder from motor�Changeable RPM during operation �Auto-lock system and double door system including steel plate inside �Patented air-flow cooling design to minimize noise and heat

    A1.5/2.0M-12 A0.2M-32

    Description Specification Remarks

    RPM / RCF

    Max. capacity

    Time

    Display

    Motor

    Accel/Decel

    Rotor

    Power supply

    Dimension

    Weight, Kg

    13,500 / 12,032xg

    1.5ml / 2.0mlx12

    0 ~ 15 min

    Analog Dial

    BLDC / 65W

    Accel 15 sec. / decel 15 sec.

    1.5/2.0ml x 12PCR 0.2ml x 4Strip(32hole)

    AC 110v/220V,50/60Hz

    190W x 202D x 129H/mm

    1.5Kg

    13,500rpm

    �Please note that technical specifications subject to change.

  • A 10-second Magic

    Micro Centrifuge

    Micro 66,500 2,234 1.5/2.0mlX 6

    All new spin-down function in Centrifuge made by Hanil.It is light, small and decreasing test time innovatively.

    Mic

    ro C

    entr

    ifuge

    HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    13

    Automatically operating from door shutting,options for basic(15sec) and continuous.

    2 action mode

    2 type rotor

    Features�Co-using Angle & PCR rotor�Spin down/continuous switching�BLDC Motor-Brushless motor provides maintenance free operation�BLDC motor for faster acceleration and deceleration�Electro sensitive non-contacting door sensor�Avoidance of contamination by carbon powder from motor

    A1.5/2.0M-6 A0.2M-16

    Description Specification Remarks

    RPM / RCF

    Max. capacity

    Motor

    Accel/Decel

    Rotor

    Power supply

    Dimension

    Weight, g

    6,500 / 2,234 xg

    1.5/2.0ml x 6

    BLDC / 30W

    Accel 9 sec. / Decel 6 sec.

    1.5/2.0ml x 6PCR 0.2ml x 16hole

    110/220V, 50/60Hz

    150W x 160D x 94H/mm

    750g

    6,500rpm

    A1.5/2.0ml x 6A0.2ml x 16

    �Operating when door closing�Spin down mode - app. 15 sec.�Continuous mode - app. 15 min.

    �Please note that technical specifications subject to change.

    Including Micro rotor and Strip rotor(0.5/1.5/2.0 ml x 6 , adapter 0.5ml x 6)Great rotor compatiblilty.

  • Mic

    ro C

    entri

    fuge

    14

    Smart choice for LabElegant design and compact sizeQuick and smooth Accelerations & Deceleration. Fast cooling and steadily sustaining Low temperature and low noise.

    Smart choice for LabNew design and technology for speedy accelerationand deceleration. Optimized safety and convenience.

  • Large CentrifugeContinent 512R I Continent 512R Plus I Combi 514R I Combi 408 Lar

    ge C

    entr

    ifuge

  • Larg

    e Ce

    ntrif

    uge

    16

    Large Capacity

    Refrigerated Centrifuge

    Large Centrifuge

    Continent512R

    Large capacity refrigerated centrifuge capable of handling180 sample units at once.

    -10�C to+40�C

    4,500 5,096 750mlX 6

    Using various tubes from 5ml to 750ml, you are able to get largesampling. (6pcs bucket)

    - Vacuumtainer Tube : 144ea- 15ml Conical Tube : 84ea- 50ml Conical Tube : 30ea

    Tube rack for various sizes of tubeTwo-staged adjustable tube rack for diverse tube lengths

    Large capacity

    ��������

    �������������

    ������������

    Wind shield Swing Bucket Rotor

    Description Specification Remarks

    RPM / RCF

    Max. capacity

    Time

    Display

    Temperature

    Motor

    Accel/Decel

    Rotor

    Power supply

    Dimension

    Weight, Kg

    4,500rpm / 5,096xg

    750ml x6

    99hrs 59min 59sec

    RPM, RCF, Time, Acc, Dec, TempLimits, Temp. ,Rotor NO.,

    Program, Rotor Radius

    -10 �C~ 40 �C

    AC Induction Motor

    0~9 (10 step)

    Swing rotor 750mlx6

    AC220V, 50/60Hz

    668W x 801D x 891H/mm

    250Kg

    WS750-6B

    WS750-6B

    Features �Using bucket style, 750ml high-capacity swing rotor�Ergonomically arranged control and display�Hi-efficient AC Induction Motor 1.7kw�Spin down (Pulse) function�User password for preventing access from random people�10 steps for speedy and gradual acceleration and deceleration

    �Please note that technical specifications subject to change.

    � �

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    17

    Continent512R Plus

    Super size multipurpose centrifuge.Sampling capacity maximum at 6L Pilot / Swing out rotor.

    -10�C to+40�C

    12,000 22,265 1000mlX 6

    Fixed angle rotor

    -10�C to+40�C

    4,500 5,096 750mlX 6

    Swingout rotor

    Capacity up to 6L at once Maximize your output!

    Mini Plant in Lab!!

    Both using Angle & Swing rotor for various sampling!

    Rotor Switching System

    Ergonomically arranged and designed machine to maximize user’sconvenience with easy mounting.

    Worried about heavy rotor mounting?

    Optimized chamber and special rubber hub attached rotor absorbsvibration to keep perfect repeatability.

    Optimized chamber for various rotors

    Larg

    e Ce

    ntrif

    uge

    Description Specification Remarks

    RPM / RCF(Swing rotor)

    RPM / RCF(Angle rotor)

    Max. capacity

    Time

    Display

    Temperature

    Motor

    Accel/Decel

    Rotor

    Power supply

    Dimension

    Weight, Kg

    4,500rpm / 5,096xg

    12,000rpm / 22,265xg

    1,000ml x 6 (Fixed angle rotor)750ml x 6 (Swing rotor)

    99hrs 59min 59sec

    RPM, RCF, Time, Acc, Dec, TempLimits, Temp. ,Rotor NO.,

    Program, Rotor Radius

    -10 �C ~ 40 �C

    AC Induction Motor

    0~9 (10 step)

    Swing rotor 750ml x 6Fixed Angle 1000ml x 6

    1000ml x 4500ml x 6250ml x 6

    AC220V, 50/60Hz

    668W x 801D x 891H/mm

    250Kg

    A250ml x 6

    S750T-6B

    S750T-6B TM96-6S A1000S-6

    �Please note that technical specifications subject to change.

    Features �Co-using Angle & Swing rotor�Using bucket style 750ml high-capacity swing rotor�Large capacity: 6 x 1,000ml rotor�Ergonomically designed control display�Hi-efficient AC Induction Motor 1.7kw�Spin down (Pulse) function�User password for preventing access from random people�10 steps for speedy and gradual acceleration and deceleration�A special suspension system enables the stable centrifugation.�The centrifuge stands on movable castors and adjustable feet to even out

    the floor

  • Larg

    e Ce

    ntrif

    uge

    18

    Large Centrifuge

    Combi 514RLarge sample handling/high-speed Bench Top refrigerated centrifuge.

    Easy to Keypad

    Easy to exchange angle or Switching Rotor for handling various samples.

    Rotor Switching System

    -10�C to+40�C

    15,000 24,878 250mlX 6

    Fixed angle rotor

    -10�C to+40�C

    4,500 4,392 750mlX 4

    Swingout rotor

    Speedy acceleration and deceleration, little noise and vibration. Capability forlarge Sample(0.2ml~750ml). Efficient Cooling by CFC Free Freezing system.

    AC Induction Motor Cooling System

    Popular Model

    Table-top Refrigerated Centrifuge

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Accel/Decel

    Temperature

    Motor

    Power supply

    Dimension

    Weight, Kg

    15,000 rpm (Fixed angle rotor)4,500 rpm (Swing rotor)

    24,878 xg (Fixed angle rotor)4,392 xg (Swing rotor)

    250ml x 6 (Fixed angle rotor)750ml x 4 (Swing rotor)

    99hrs 59min 59sec

    RPM, RCF, Time, Temperature,Program, Temp.Limit,

    Accel/Decel Time, Rotor Number,Rotor Radius

    10 step

    -10 �C~ 40 �C

    AC Induction Motor

    220V,50/60Hz, single phase

    723W x 665D x 387H/mm

    112Kg

    A50S-8S750T-4B

    A50S-8S750T-4B

    S750T-4B TM96-4S A250S-6

    Features �Co-using Angle & Swing rotor�Using bucket style 750ml high-capacity swing rotor�Ergonomically arranged and designed�Spin down (Pulse function)�Customized key pad (Easy operation and correction)�10 steps for acceleration and deceleration can be selected for delicate liquid

    experiment�Eco-friendly CFC Free freezing system�RPM/RCF auto calculating�Changing term of timer during operation�Radius of rotor set up by unit of 0.1mm�Memory for saving experiment condition�Fast Cooling(down to 4�C in 15 min) �Short spin key : Spin down in 1 min�lid latch by motor : preventing imbalance of sample

    Applied easy to use control pad for anybody.

    �Please note that technical specifications subject to change.

  • Larg

    e Ce

    ntrif

    uge

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Accel/Decel

    Motor

    Power supply

    Dimension

    Weight, Kg

    8,000 rpm (Fixed angle rotor)4,000 rpm (Swing rotor)

    8,279 xg (Fixed angle rotor)3,515 xg (Swing rotor)

    85ml x 6 (Fixed angle rotor)750ml x 4 (Swing rotor)

    1hrs 59min 59sec

    RPM, RCF, Time, Program, Accel/Decel Time,

    Rotor Number, Rotor Radius

    10 step

    BLDC Motor 1.5Kw

    220V, 60Hz, single phase

    530W x 676D x 400H/mm

    70Kg

    S750T-4B

    A85S-6

    S750T-4B TM96-4S A85S-6

    Features �Co-using Angle & PCR rotor�Using bucket style 750ml high-capacity swing rotor�Ergonomically arranged and designed�Spin down (Pulse) function�Customized key pad (Easy operation and correction)�10 steps for acceleration and deceleration can be selected for delicate

    liquid experiment�RPM/RCF auto calculating�Changing term of timer during operation�Radius of rotor set up by unit of 0.1mm�Memory for saving experiment condition

    Air cooling

    Large Centrifuge

    Large Centrifuge

    Combi 4088,000

    Fixed angle rotor

    8,279 85mlX 6 4,000

    Swingout rotor

    3,515 750mlX 4

    Multipurpose Large Centrifuge used in hospitals, universitiesand laboratories.

    Speedy acceleration/deceleration, noiseless and motionless,large sampling (15ml~750ml)

    BLDC Motor

    Easy to use control panel for everyone.

    Easy to Keypad

    Space-saving design for interior.

    Compact design

    �Please note that technical specifications subject to change.

    HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    19

  • Larg

    e Ce

    ntrif

    uge

    20

    Continent 512R / Plus

    Control Display�10 steps for acceleration and deceleration for delicate

    liquid experiment�RPM/RCF auto calculating�Changing term of timer during operation�Time set up to 99:59:59�Radius of rotor set up by unit of 0.1mm�100 memories

    Continent-512R Plus Rotor

    Safety�Auto security & alarm system�motor RPM and imbalance recognition�Door lock, emergency lock recognition, and auto rotor

    recognition

    Description S750T-6B

    Max RPM

    Max RCF

    Max R(mm)

    Rotor NO.

    Max Tube Capacity

    4,500 rpm

    5,096xg

    225.1mm

    14

    750ml x 6

    A1000S-6

    7,000rpm

    10,962 xg

    200.1mm

    13

    1000ml x 6

    A1000S-4

    8,000rpm

    12,157 xg

    169.9mm

    12

    1000ml x 4

    A500S-6

    10,000rpm

    17,743 xg

    158.7mm

    11

    500ml x 6

    A250S-6

    12,000rpm

    20,929 xg

    130mm

    10

    250ml x 6

  • Combi 408

    HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    21

    Larg

    e Ce

    ntrif

    uge

    Combi 514R

    Control Display�Easy and fast working and correction by using Easy to Key Pad �10 steps for acceleration and deceleration for delicate liquid experiment�RPM/RCF auto calculating�Timer in motion�Rotor Radius 0.1mm setting

    Various rotors and accessories for convinience

    CFC Free Freezing system: Freezing system by using eco-friendly refrigerant

    Optimized air-cycling system

    Safety�Auto security & alarm system�motor RPM and imbalance recognition�Door lock, emergency lock recognition, and auto rotor recognition

    Optimized freezing system (for all refridging model)

  • Larg

    e Ce

    ntrif

    uge

    22

    Large centrifuge accessories

    Swing Rotors

    S500T- 4B No.12

    Type

    Max. RPM

    Max. RCF

    Radius

    Dim.

    Swing Rotor �90°C

    4,500 rpm

    4,392 xg

    194 mm

    262 x 262 x 62 mm

    Tube Capacity (ml)

    Dimensions � x L mm

    Tube Type

    5

    12 x 75

    26

    104

    3,433

    191.9

    4,000

    13 x 70

    Magenta

    T5-26

    13 x 153.5

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    10

    16 x 100

    9

    36

    4,279

    189.0

    4,500

    17 x 64

    Cyan

    TR10-9

    17x151

    15

    16 x 114

    9

    36

    4,290

    189.5

    4,500

    16.5 x 85

    Khaki

    TR15-9

    16.5x151.5

    50

    29 x 104

    4

    16

    4,290

    189.5

    4,500

    30 x 85.5

    Sky Blue

    TR50-4

    30x151.5

    100(85ml)

    38 x 105.7

    1

    4

    4,290

    189.5

    4,500

    38.5 x 84.5

    Brown

    TR100-1

    38.5x151.5

    250

    61.8 x 123

    1

    4

    4,290

    189.5

    4,500

    62 x 100

    Violet

    TR250-1

    62x151.5

    500

    69.5 x 170.2

    1

    4

    4,347

    192.0

    4,500

    73 x 101

    Chartreuse

    TR500-1

    73x154

    50

    30 x 115

    3

    12

    4,302

    190.0

    4,500

    30 x 90

    Blue

    TR50-3C

    30x152

    15

    17 x 120

    7

    28

    4,313

    190.5

    4,500

    17 x 95.5

    Pink

    TR15-7C

    17x152.5

    MTP

    -

    4

    3,486

    154.0

    4,000

    -

    -

    -

    -

    Combi 514R Max. RPM : 4,500 Max. RCF : 4,392 xg Combi 408 Max. RPM : 4,000 Max. RCF : 3,470 xg

    B500

    Round Bucket500ml capacity

    B500 Lid

    Sealing Cap

    TM96-4S

    MicroTiter Plate rack

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    23

    Larg

    e Ce

    ntrif

    uge

    S750T - 4B No.13

    Type

    Max. RPM

    Max. RCF

    Radius

    Dim.

    Swing Rotor �90°C

    4,000 rpm

    3,515 xg

    196.5 mm

    277 x 277 x 55 mm

    Tube Capacity (ml)

    Dimensions � x L mm

    Tube Type

    5

    12 x 75

    26

    104

    3,433

    191.9

    4,000

    13 x 70

    Magenta

    T5-26

    13 x 153.5

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    10

    13 x 100

    26

    104

    3,417

    191.0

    4,000

    14 x 89.5

    Yellow

    T10-26

    14 x 152.5

    15

    16 x 114

    19

    76

    3,438

    192.2

    4,000

    17 x 99.5

    Green

    T15-19

    17 x 151

    50

    29 x 104

    7

    28

    3,288

    183.8

    4,000

    29.2 x 81

    White

    T50-7

    29.2 x 145

    250

    61.8 x 123

    1

    4

    3,463

    193.6

    4,000

    62.2 x 99

    Cyan

    T250-1

    62.2 x 155

    500

    69.5 x 170.2

    1

    4

    3,458

    193.3

    4,000

    75.5 x 99

    Violet

    T500-

    75.5 x 55

    750

    97 x 152

    -

    4

    3,515

    196.5

    4,000

    99 x 105

    -

    -

    99 x 158

    50

    30 x 115

    5

    20

    3,452

    193.0

    4,000

    29.5 x 99.5

    Blue

    T50-5C

    29.5 x 146.5

    15

    17 x 120

    14

    56

    3,413

    190.8

    4,000

    17 x 89

    Sky Blue

    T15-14C

    17 x 152

    MTP

    -

    4

    2,925

    163.5

    4,000

    -

    -

    -

    -

    50

    5

    20

    3,336

    186.5

    4,000

    27 x 65

    Black

    TS50-5

    27 x 90

    30

    120

    3,336

    186.5

    4,000

    13 x 55

    Crimson

    T5-30

    13 x 148

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    24

    29

    3,336

    186.5

    4,000

    13.5 x 80

    Yellow

    T10-24

    13.5 x 148

    17

    68

    3,336

    186.5

    4,000

    17.3 x 80

    Green

    T15-17

    17.3 x 148

    4

    16

    3,336

    186.5

    4,000

    29 x 80

    White

    T50-4

    29 x 148

    1

    4

    3,336

    186.5

    4,000

    62 x 80

    Red

    T250-1

    62 x148

    1

    4

    3,336

    186.5

    4,000

    74 x 80

    Blue

    T500-1

    74 x 148

    B750

    Round Bucket750ml capacity

    B750 Lid

    Sealing Cap

    TM96-4S

    MicroTiter Plate rack

    Combi 514R Max. RPM : 4,000 Max. RCF : 3,515 xg Combi 408 Max. RPM : 4,000 Max. RCF : 3,515 xg

    Swing Rotors

  • Larg

    e Ce

    ntrif

    uge

    24

    WS750 - 6B Wind shield

    Type

    Max. RPM

    Max. RCF

    Radius

    Dim.

    Swing Rotor �90°C

    4,500 rpm

    5,096 xg

    225.1 mm

    333.5 x 381 x 61.5 mm

    Tube Capacity (ml)

    Dimensions � x L mm

    Tube Type

    5

    12 x 75

    26

    156

    4,992

    220.5

    4,500

    13 x 0

    Magenta

    T5-26

    13 x 157

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    10

    13 x 100

    26

    156

    4,972

    219.6

    4,500

    14 x 89.5

    Yellow

    T10-26

    14 x 156.5

    15

    16 x 114

    19

    114

    4,997

    220.7

    4,500

    17 x 99.5

    Green

    T15-19

    17 x 157.5

    50

    29 x 104

    7

    42

    4,809

    212.4

    4,500

    29.2 x 81

    White

    T50-7

    29.2 x 149

    250

    61.8 x 123

    1

    6

    5,030

    222.2

    4,500

    62.2 x 99

    Cyan

    T250-1

    62.2 x 159

    500

    69.5 x 170.2

    1

    6

    5,024

    221.9

    4,500

    75.5 x 99

    Violet

    T500-1

    75.5 x 158.5

    750

    97 x 152

    -

    6

    5,094

    225.0

    4,500

    99x105

    -

    -

    99 x 162

    50

    30 x 115

    5

    30

    5,071

    221.6

    4,500

    29.5 x 99.5

    Blue

    T50-5C

    29.5 x 158.5

    15

    17 x 120

    14

    84

    4,967

    219.4

    4,500

    17 x 89

    Sky Blue

    T15-14C

    17 x 156

    MTP

    -

    6

    3,433

    191.9

    4,500

    -

    -

    -

    -

    50

    5

    30

    4,870

    215.1

    4,500

    27 x 65

    Black

    TS50-5

    27 x 90

    30

    180

    4,870

    215.1

    4,500

    13 x 55

    Crimson

    T5-30

    17 x 152

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    24

    144

    4,870

    215.1

    4,500

    13.5 x 80

    Yellow

    T10-24

    13.5 x 152

    17

    102

    4,870

    215.1

    4,500

    17.3 x 80

    Green

    T15-17

    17.3 x 152

    4

    24

    4,870

    215.1

    4,500

    29 x 80

    White

    T50-4

    29 x 152

    1

    6

    4,870

    215.1

    4,500

    62 x 80

    Red

    T250-1

    62 x 152

    1

    6

    4,870

    215.1

    4,500

    74 x 80

    Blue

    T500-1

    74 x 152

    B750

    Round Bucket750ml capacity

    B750 Lid

    Sealing Cap

    TM96-4S

    MicroTiter Plate rack

    Continent 512R Max. RPM : 4,500 Max. RCF : 5,096 xg

    Swing Rotors

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    25

    Larg

    e Ce

    ntrif

    uge

    S750T - 6B No.14

    Type

    Max. RPM

    Max. RCF

    Radius

    Dim.

    Swing Rotor �90°C

    4,500 rpm

    5,096 xg

    225.1 mm

    333.7 x 362 x 55 mm

    Tube Capacity (ml)

    Dimensions � x L mm

    Tube Type

    5

    12 x 75

    26

    156

    4,992

    220.5

    4,500

    13 x 0

    Magenta

    T5-26

    13 x 157

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    10

    13 x 100

    26

    156

    4,972

    219.6

    4,500

    14 x 89.5

    Yellow

    T10-26

    14 x 156.5

    15

    16 x 114

    19

    114

    4,997

    220.7

    4,500

    17 x 99.5

    Green

    T15-19

    17 x 157.5

    50

    29 x 104

    7

    42

    4,809

    212.4

    4,500

    29.2 x 81

    White

    T50-7

    29.2 x 149

    250

    61.8 x 123

    1

    6

    5,030

    222.2

    4,500

    62.2 x 99

    Cyan

    T250-1

    62.2 x 159

    500

    69.5 x 170.2

    1

    6

    5,024

    221.9

    4,500

    75.5 x 99

    Violet

    T500-1

    75.5 x 158.5

    750

    97 x 152

    -

    6

    5,094

    225.0

    4,500

    99x105

    -

    -

    99 x 162

    50

    30 x 115

    5

    30

    5,071

    221.6

    4,500

    29.5 x 99.5

    Blue

    T50-5C

    29.5 x 158.5

    15

    17 x 120

    14

    84

    4,967

    219.4

    4,500

    17 x 89

    Sky Blue

    T15-14C

    17 x 156

    MTP

    -

    6

    3,433

    191.9

    4,500

    -

    -

    -

    -

    50

    5

    30

    4,870

    215.1

    4,500

    27 x 65

    Black

    TS50-5

    27 x 90

    30

    180

    4,870

    215.1

    4,500

    13 x 55

    Crimson

    T5-30

    17 x 152

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    24

    144

    4,870

    215.1

    4,500

    13.5 x 80

    Yellow

    T10-24

    13.5 x 152

    17

    102

    4,870

    215.1

    4,500

    17.3 x 80

    Green

    T15-17

    17.3 x 152

    4

    24

    4,870

    215.1

    4,500

    29 x 80

    White

    T50-4

    29 x 152

    1

    6

    4,870

    215.1

    4,500

    62 x 80

    Red

    T250-1

    62 x 152

    1

    6

    4,870

    215.1

    4,500

    74 x 80

    Blue

    T500-1

    74 x 152

    B750

    Round Bucket750ml capacity

    B750 Lid

    Sealing Cap

    TM96-4S

    MicroTiter Plate rack

    Continent 512R Plus Max. RPM : 4,500 Max. RCF : 5,096 xg

    Swing Rotors

  • Larg

    e Ce

    ntrif

    uge

    26

    A0.2S-48 No.18Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �45°C12,500 rpm

    15,530 xg

    88.9 mm

    0.2ml

    6 x 18

    0.2ml

    4848

    15,530

    88.9

    6.5 x 15

    6-Strips

    Combi 514RMax. RPM : 12,500Max. RCF : 15,530 xg

    Combi 408Max. RPM : 8,000Max. RCF : 6,361 xg

    A10S-12 No.2Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �36°C30,000 rpm

    85,628 xg

    85.1 mm

    10ml

    16 x 82

    12

    85,628

    85.1

    16.3 x 74.5

    Combi 514RMax. RPM : 15,000Max. RCF : 21,407 xg

    Combi 408Max. RPM : 8,000Max. RCF : 6,089 xg

    A15S-12C No.8Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C17,000 rpm

    32,116 x g

    99.4 mm

    15ml

    17 x 120

    12

    32,116

    99.4

    17 x 115

    Combi 514RMax. RPM : 15,000Max. RCF : 25,004 xg

    Combi 408Max. RPM : 8,000Max. RCF : 7,112 xg

    A1.5S-24 No.1Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �40°C30,000 rpm

    81,301 xg

    80.8 mm

    0.2ml

    6 x 18

    0.5ml

    8 x 30

    61,982

    61.6

    6 x 21

    70,434

    70.0

    8 x 37

    1.5ml

    11 x 38

    2.0ml

    11 x 38

    81,301

    80.8

    11 x 37.5

    24

    Combi 514RMax. RPM : 15,000Max. RCF : 20,325 xg

    Combi 408Max. RPM : 8,000Max. RCF : 5,781 xg

    A1.5S-36 No.14Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �45°C20,000 rpm

    52,546 xg

    115.7 mm

    0.2ml

    6 x 18

    0.5ml

    8 x 30

    42,573

    95.2

    6 x 21

    46,643

    104.3

    8 x 37

    1.5ml

    11 x 38

    2.0ml

    11 x 38

    52,546

    115.7

    11 x 37.5

    36

    Combi 514RMax. RPM : 14,000Max. RCF : 25,353 xg

    Combi 408Max. RPM : 8,000Max. RCF : 8,279 xg

    Angle Rotors

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    27

    Larg

    e Ce

    ntrif

    uge

    A15S-12 No.4Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C30,000 rpm

    96,696 xg

    96.1 mm

    15(16)ml

    18 x 100

    12

    96,696

    96.1

    19 x 96

    Combi 514RMax. RPM : 15,000Max. RCF : 24,174 xg

    Combi 408Max. RPM : 8,000Max. RCF : 6,876 xg

    A85S-6 No.9Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C25,000 rpm

    64,425 xg

    92.2 mm

    85ml

    38.2 x 105.7

    6

    64,425

    92.2

    38.5 x 90

    Combi 514RMax. RPM : 15,000Max. RCF : 23,193 xg

    Combi 408Max. RPM : 8,000Max. RCF : 6,597 xg

    A50S-6C No.6Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �40°C17,000 rpm

    29,402 xg

    91 mm

    50ml

    29 x 115

    6

    29,402

    91.0

    29.5 x 108.6

    Combi 514RMax. RPM : 15,000Max. RCF : 22,891 xg

    Combi 408Max. RPM : 8,000Max. RCF : 6,511 xg

    A50S-6 No.5Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �30°C30,000 rpm

    96,696 xg

    96.1 mm

    15(16)ml

    18 x 100

    50ml

    28.8 x 107

    50ml

    28.7 x 104

    90,558

    90.0

    18.5 x 92

    6

    96,696

    96

    29 x 100

    Combi 514RMax. RPM : 15,000Max. RCF : 24,174 xg

    Combi 408Max. RPM : 8,000Max. RCF : 6,876 xg

    A50S-8 No.7Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �36°C30,000 rpm

    99,513 xg

    98.9 mm

    15(16)ml

    18 x 100

    50ml

    28.8 x 107

    50ml

    28.7 x 104

    93,375

    92.8

    18.5 x 92

    8

    99,513

    98.9

    29 x 100

    Combi 514RMax. RPM : 15,000Max. RCF : 24,878 xg

    Combi 408Max. RPM : 8,000Max. RCF : 7,076 xg

    Angle Rotors

  • Larg

    e Ce

    ntrif

    uge

    28

    A85S-10 No.17Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �33°C15,000 rpm

    32,601 xg

    129.6 mm

    85ml

    38.2 x 105.7

    10

    32,601

    129.6

    38.5 x 97

    Combi 514RMax. RPM : 10,000Max. RCF : 14,489 xg

    A250S-6 No.10Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C14,000 rpm

    30,305 xg

    138.3mm

    250ml

    61.8 x 127.7

    250ml

    61 x 134

    6

    30,305

    138.3

    62 x 103

    Combi 514RMax. RPM : 10,000Max. RCF : 15,462 xg

    Continent 512R PlusMax. RPM : 12,000Max. RCF : 22,265 xg

    A500S-6 No.11Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C10,000 rpm

    17,743 xg

    158.7 mm

    500ml

    69.5 x 170

    6

    17,743

    158.7

    70 x 141

    Continent 512R PlusMax. RPM : 10,000Max. RCF : 17,743 xg

    A1000S-4 No.11Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C8,000 rpm

    12,157 xg

    169.9 mm

    1000ml

    96 x 176

    4

    12,157

    169.9

    97 x 144

    Continent 512R PlusMax. RPM : 8,000Max. RCF : 12,157 xg

    A1000S-6 No.13Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C7,000 rpm

    10,962 x g

    200.1 mm

    1000ml

    96 x 176

    6

    10,962

    200.1

    97.5 x 144

    Continent 512R PlusMax. RPM : 7,000Max. RCF : 10,962 xg

    Angle Rotors

  • Ultra / High Speed CentrifugeSupra 22K I Mega 17R I Supra 30K I Supra 25K I Ultra 5.0 I Ultra 4.0 U

    ltra

    / Hig

    hSp

    eed

    Cent

    rifug

    e

  • High

    Spe

    ed C

    entri

    fuge

    30

    Ergonomically designed model of High Speed Centrifuge.

    Silence Safety Speed

    Supra 22K

    High Speed Centrifuge

    Easy to use Control panel for everyone.

    Easy to Keypad

    Ergonomically arranged and designed machine, Supra 22K maximizes user’sconvenience with easy connecting.

    Worried about heavy rotor connecting?

    Great presenting by powerful AC Induction motor.

    High Torque Drive System

    Switching door open system preventing damage of sample when power off.

    Emergency System

    Automatically identifying rotor for user’s convenience.

    Rotor Identification System

    -10�C to+40�C

    22,000 53,029 1,000mlX 4

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Accel/Decel

    Temperature

    Motor

    Power supply

    Dimension

    Weight, Kg

    22,000rpm

    53,029 xg

    1,000ml x 4

    99hrs 59min 59sec

    RPM, RCF, Time, Temperature, Program, Temp.Limit, Accel/Decel,

    Rotor Number,Rotor Radius

    10 step

    -10 �C~ 40 �C

    AC Induction Motor

    220V, 60Hz, single phase

    668W x 801D x 891H/mm

    230Kg

    Features �One chip microprocessor control�Customized key pad (Easy operation and correction)�Memory for saving experiment condition �RPM/RCF auto calculating�Changing term of timer during operation�10 steps for acceleration and deceleration for delicate liquid experiment�Spin-down�Maximum Fixed Angle Rotor 1,000ml x 4�Patented compressor technology reduces vibrations and protects your

    sample�PWM (pulse width modulation) motor control has realized�AC Induction drive technology provides you with fast separations�Shorter run times mean more discovery for you. Supra22K high torque

    switched reluctance drive gives you more time at speed and less timegetting there

    A500S-6 A250S-6 A85S-6

    A15S-12A50S-8 A1.5S-24

    �Please note that technical specifications subject to change.

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    31

    Ergonomically arranged and designed for user’s interface.

    Compact Design

    Easy to use Control panel for everyone.

    Easy to Keypad

    Great presenting by powerful AC Induction motor.

    High Torque Drive System

    Switching door open system preventing damage of sample when power off.

    Emergency System

    Ultr

    a / H

    igh

    Spee

    d Ce

    ntrif

    uge

    High Speed

    Refrigerated Centrifuge

    Mega 17R

    High Speed Centrifuge

    -10�C to+40�C

    17,000 31,341 85mlX 6

    Economic Model of High Speed Centrifuge.

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Accel/Decel

    Temperature

    Motor

    Power supply

    Dimension

    Weight, Kg

    17,000 rpm

    31,341 xg

    85ml x 6

    9hrs 59min 59sec

    RPM, RCF, Time, Temperature,Temp.Limit, Program, Brake Time,

    Rotor Number

    3 step

    -10 �C~ 40 �C

    AC Induction Motor

    220V, 60Hz, single phase

    550W x 600D x 865H/mm

    140Kg

    Features �Microprocessor control�Simple way to operate�CFC Free freezing system�RPM/RCF auto calculating�Feed back control system�AC induction motor with no brush�Memory for saving experiment condition�Various angle fixed rotor

    �Please note that technical specifications subject to change.

    A50S-8 A1.5mlx24

  • High

    Spe

    ed C

    entri

    fuge

    32

    High Speed Centrifuge capable of 25,000~30,000 RPM &4,000ml separation.

    High Speed

    Vacuum Centrifuge

    Supra 30K

    High Speed Centrifuge

    Various rotors and tubes in need usable (1.5ml~1000ml)

    Accurate temperature control by temperature recognition function.

    Temp, Limit System

    -10�C to+40�C

    30,000 98,608 1,000mlX 4

    Easy cleaning and preventing contamination during use of machine.

    Contamination Prevention System

    Various rotors available

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Accel/Decel

    Temperature

    Motor

    Power supply

    Dimension

    Weight, Kg

    30,000 rpm

    98,608 xg

    1,000ml x 4

    99hrs 59min 59sec

    RPM, RCF, Time, Temperature,Temp.Limit, Program,

    Accel/Decel Time, Rotor Number,Rotor Radius, Self Test,��2dt

    10 step

    -10 �C ~ 40 �C

    AC Induction Motor

    220V, 60Hz, single phase

    710W x 1,000D x 1,260H/mm

    330Kg

    Features �One chip microprocessor control�Easy control of operation�Well engineered design of motor assures sound quality�Environmental refrigerating system of cfc-free�Automatic RPM/RCF calculating system�Feed-back system of vacuum control system�Rotor of autoclave endurance�high vacuum system and the especially flexible driving system of ultra

    high speed�Ultra fine structure such as microbe and virus can be treated�Vacuum pressure is precisely measured by digital gauge

    �Please note that technical specifications subject to change.

    A500S-6 A250S-6 A85S-6

    A15S-12A50S-8 A1.5S-24

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    33

    Various rotors and tubes in need usable (1.5ml~1000ml)

    Accurate temperature control by temperature recognition function.

    Temp, Limit System

    Easy cleaning and preventing contamination during use of machine.

    Contamination Prevention System

    Various rotors available

    High speed and user friendly centrifuge with refrigeration &vacuum system in volume of 4,000ml.

    High Speed

    Vacuum Centrifuge

    Supra 25K

    High Speed Centrifuge

    -10�C to+40�C

    25,000 68,478 1,000mlX 4

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Accel/Decel

    Temperature

    Motor

    Power supply

    Dimension

    Weight, Kg

    25,000 rpm

    68,478 xg

    1000ml x 4

    99hrs 59min 59sec

    RPM, RCF, Time, Temperature,Temp.Limit, Program,

    Accel/Decel Time, Rotor Number,Rotor Radius, Self Test,��2dt

    10 step

    -10 �C~ 40 �C

    AC Induction Motor

    220V, 60Hz, single phase, 3.9KW

    710W x 1000D x 1260H/mm

    330Kg

    Features �One chip microprocessor control�Easy control of operation�Well engineered design of motor assures sound quality�Environmental refrigerating system of cfc-free�Automatic RPM/RCF calculating system�Feed-back vacuum control system�High vacuum system and especially flexible driving system of ultra

    high speed�Vacuum pressure is precisely measured by digital gauge�New Carbon Fiber Rotor�HFC R404A with the ODP = 0.0, which contains no chlorine to

    destroy the ozone layer, is used to reduce environmental impact

    �Please note that technical specifications subject to change.

    Ultr

    a / H

    igh

    Spee

    d Ce

    ntrif

    uge

    A500S-6 A250S-6 A85S-6

    A15S-12A50S-8 A1.5S-24

  • Ultra

    Cen

    trifu

    ge

    34

    Vacuum freezing system, various Ultra tubes available formicroscopic tissue separation.

    The very first

    Ultra Series, since 1997

    Ultra 5.0

    Ultra Centrifuge

    -10�C to+40�C

    50,000 254,345 250mlX 6

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Accel/Decel

    Temperature

    Motor

    Power supply

    Dimension

    Weight, Kg

    50,000 rpm

    254,345 xg

    250ml x 6

    99hrs 59min 59sec

    RPM, RCF, Time, Temperature,Temp.Limit,

    Program, Accel/Decel ,Rotor Number, Rotor Radius,

    Self Test,��2dt

    10 step

    -10 �C ~ 40 �C

    AC Induction Motor

    220V, 60Hz, single phase

    710W x 1,000D x 1,260H/mm

    430Kg

    One-chip microprocessor control250,000 xg / 50,000 RPM.

    Accurate RPM repeatability

    High vacuum system and high-speed flexibledrive system.

    Durability

    DNA, RNA, Protein separation by 50,000 rpm.

    Ultra Speed in economic price

    A38.5U-8 A250U-6

    Features �Maximum rotating speed : 50,000 rpm (254,345xg)�Sealing system prevents leaking out of hazardous substance�Surface treatment of rotor avoids the corrosion by caustic agent�Control of operation is easy�Well engineered design assures sound quality�Autoclave of motor is workable�High vacuum and especially flexible driving system of ultra high speed�Ultra fine structure such as microbe and virus can be treated�Vacuum pressure is precisely measured by digital gauge�The intuitive user interface consists of an interactive color touch-screen and

    a positive feedback keypad for quick protocol setup and storage�Embedded software enables better control of multi-user access, greater

    convenience and improved safety

    �Please note that technical specifications subject to change.

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    35

    Ultr

    a / H

    igh

    Spee

    d Ce

    ntrif

    uge

    High vacuum system and high-speed flexibledrive system.

    Durability

    DNA, RNA, Protein separation by 50,000 rpm.

    Ultra Speed in economic price

    Vacuum freezing system, various Ultra tube available formicroscopic tissue separation.

    The very first

    Ultra Series, since 1997

    Ultra 4.0

    Ultra Centrifuge

    -10�C to+40�C

    40,000 175,302 250mlX 6

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Accel/Decel

    Temperature

    Motor

    Power supply

    Dimension

    Weight, Kg

    40,000 rpm

    175,302 xg

    250ml x 6

    99hrs 59min 59sec

    RPM, RCF, Time, Temperature,Temp.Limit,

    Program, Accel/Decel,Rotor Number, Rotor Radius,

    Self Test,��2dt

    10 step

    -10 �C~ 40 �C

    AC Induction Motor

    220V, 60Hz, single phase

    710W x 1,000D x 1,260H/mm

    430Kg

    A38.5U-8 A250U-6

    �Please note that technical specifications subject to change.

    Features �Maximum speed of rotating : 40,000 rpm (175,302xg) �Sealing system prevents leaking out of hazardous substance�Surface treatment of rotor avoids the corrosion by the caustic components.�Control of operation is easy�High vacuum system and especially flexible driving system of ultra high speed.�Ultra fine structure such as microbe and virus can be treated�Vacuum pressure is precisely measured by digital gauge

  • Ultra

    / Hi

    gh S

    peed

    Cen

    trifu

    ge

    36

    Supra 22K

    Ultra 4.0 / 5.0Supra 25 / 30K

    Special hub(Upper)

    Special vacuum rubber

    Special hub(Lower)

    �Double layered vibration absorbing system of shock proofunder patent

    �Superior durability of bearings �Easy balancing work�Excellent durability and convenience

    �Double layered vibration absorbing system of shock proofunder patent

    �Superior durability of bearings �Easy balancing work�Excellent durability and convenience

    Special structure of rubber hub

    Control Display�Customized Key Pad (Easy-to-use operation and correction)�10 steps for acceleration and deceleration can be selected for

    delicate liquid experiment�Automatic RPM/RCF calculating system�Changing term of timer during operation�Time set up, max. 99 hours 59 minutes 59secs�Radius of rotor set up by unit of 0.1mm�Memory for saving experiment condition [100 memories]

    Supra, Continent 512R, Combi, Mega Series

    Supra 25 / 30K

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    37

    Ultr

    a / H

    igh

    Spee

    d Ce

    ntrif

    uge

    �Rotor with easy loading and unloading�Compensation function of rotor with the special structure under patent

    Special hub

    Special lock

    Jut(rotating) Flat(stop)

    �Recognition of motor imbalance to stopworking. Based on theory that resistance canbe different by proximity of magnet and hallsensor resistance

    Ultra 4.0 / 5.0

    Supra, Continent 512R, Combi Series

    �Analyzing the phase of the ultra high speed rotor�Principle- Rotation of body generates centrifugical force-Value of centrifugical force is proportioned to density X radius X rpm square�Design is for the safety of operator performing the ultra high speed rotation

  • Ultra

    / Hi

    gh S

    peed

    Cen

    trifu

    ge

    38

    A1.5S-36 No.14Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �45°C20,000 rpm

    52,546 xg

    115.7 mm

    0.2ml

    6 x 18

    0.5ml

    8 x 30

    42,573

    95.2

    6 x 21

    46,643

    104.3

    8 x 37

    1.5ml

    11 x 38

    2.0ml

    11 x 38

    52,546

    115.7

    11 x 37.5

    36

    Mega 17RMax. RPM : 15,000Max. RCF : 29,104 xg

    Supra 22KMax. RPM : 18,000Max. RCF : 41,910 xg

    Supra 25KMax. RPM : 20,000Max. RCF : 51,741xg

    Supra30KMax. RPM : 20,000Max. RCF : 51,741 xg

    Angle Rotors (High Speed Centrifuge)

    A10S-12 No.2Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �36°C30,000 rpm

    85,628 xg

    85.1 mm

    10ml

    16 x 82

    12

    85,628

    85.1

    16.3 x 74.5

    Mega 17RMax. RPM : 17,000Max. RCF : 27,496 xg

    Supra 22KMax. RPM : 22,000Max. RCF : 46,049 xg

    Supra 25KMax. RPM : 25,000Max. RCF : 59,464 xg

    Supra30KMax. RPM : 30,000Max. RCF : 85,628 xg

    A15S-12C No.8Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C17,000 rpm

    32,116 x g

    99.4 mm

    15ml

    17 x 120

    12

    32,116

    99.4

    17 x 115

    Mega 17RMax. RPM : 15,000Max. RCF : 25,004 xg

    Supra 22KMax. RPM : 17,000Max. RCF : 32,116 xg

    Supra 25KMax. RPM : 17,000Max. RCF : 32,116 xg

    Supra30KMax. RPM : 17,000Max. RCF : 32,116 xg

    A15S-12 No.4Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C30,000 rpm

    96,696 xg

    96.1 mm

    15(16)ml

    18 x 100

    12

    96,696

    96.1

    19 x 96

    Mega 17RMax. RPM : 17,000Max. RCF : 31,050 xg

    Supra 22KMax. RPM : 22,000Max. RCF : 52,001 xg

    Supra 25KMax. RPM : 25,000Max. RCF : 67,150 xg

    Supra30KMax. RPM : 30,000Max. RCF : 96,696 xg

    A50S-6C No.6Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �40°C17,000 rpm

    29,402 xg

    91 mm

    50ml

    29 x 115

    6

    29,402

    91.0

    29.5 x 108.6

    Mega 17RMax. RPM : 15,000Max. RCF : 22,891 xg

    Supra 22KMax. RPM : 17,000Max. RCF : 29,402 xg

    Supra 25KMax. RPM : 17,000Max. RCF : 29,402 xg

    Supra30KMax. RPM : 17,000Max. RCF : 29,402 xg

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    39

    Ultr

    a / H

    igh

    Spee

    d Ce

    ntrif

    uge

    Angle Rotors (High Speed Centrifuge)

    A50S-6 No.5Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �30°C30,000 rpm

    96,696 xg

    96.1 mm

    15(16)ml

    18 x 100

    50ml

    28.8 x 107

    50ml

    28.7 x 104

    90,558

    90.0

    18.5 x 92

    6

    96,696

    96

    29 x 100

    Mega 17RMax. RPM : 17,000Max. RCF : 31,050 xg

    Supra 22KMax. RPM : 22,000Max. RCF : 52,001 xg

    Supra 25KMax. RPM : 25,000Max. RCF : 67,150 xg

    Supra30KMax. RPM : 30,000Max. RCF : 96,696 xg

    A50S-8 No.7Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �36°C30,000 rpm

    99,513 xg

    98.9 mm

    15(16)ml

    18 x 100

    50ml

    28.8 x 107

    50ml

    28.7 x 104

    93,375

    92.8

    18.5 x 92

    8

    99,513

    98.9

    29 x 100

    Mega 17RMax. RPM : 15,000Max. RCF : 24,878 xg

    Supra 22KMax. RPM : 22,000Max. RCF : 53,516 xg

    Supra 25KMax. RPM : 25,000Max. RCF : 69,106 xg

    Supra30KMax. RPM : 30,000Max. RCF : 99,513 xg

    A85S-6 No.9Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C25,000 rpm

    64,425 xg

    92.2 mm

    85ml

    38.2 x 105.7

    6

    64,425

    92.2

    38.5 x 90

    Mega 17RMax. RPM : 15,000Max. RCF : 23,193 xg

    Supra 22KMax. RPM : 20,000Max. RCF : 41,232 xg

    Supra 25KMax. RPM : 25,000Max. RCF : 64,425 xg

    Supra30KMax. RPM : 25,000Max. RCF : 64,425 xg

    A250S-6 No.10Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C14,000 rpm

    30,305 xg

    138.3mm

    250ml

    61.8 x 127.7

    250ml

    61 x 134

    6

    30,305

    138.3

    62 x 103

    Supra 22KMax. RPM : 12,000Max. RCF : 22,265 xg

    Supra 25KMax. RPM : 14,000Max. RCF : 30,305 xg

    Supra30KMax. RPM : 14,000Max. RCF : 30,305 xg

    A500S-6 No.11Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C10,000 rpm

    17,743 xg

    158.7 mm

    500ml

    69.5 x 170

    6

    17,743

    158.7

    70 x 141

    Supra 22KMax. RPM : 9,000Max. RCF : 14,372 xg

    Supra 25KMax. RPM : 10,000Max. RCF : 17,743 xg

    Supra30KMax. RPM : 10,000Max. RCF : 17,743 xg

  • Ultra

    / Hi

    gh S

    peed

    Cen

    trifu

    ge

    40

    Angle Rotors (High Speed Centrifuge)

    A1000S-4 No.12Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C8,000 rpm

    12,157 xg

    169.9 mm

    1000ml

    96 x 176

    4

    12,157

    169.9

    97 x 144

    Supra 22KMax. RPM : 8,000Max. RCF : 12,157 xg

    Supra 25KMax. RPM : 8,000Max. RCF : 12,157 xg

    Supra30KMax. RPM : 8,000Max. RCF : 12,157 xg

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    41

    Ultr

    a / H

    igh

    Spee

    d Ce

    ntrif

    uge

    Angle Rotors (Ultra High Speed Centrifuge)

    A1.5U-24 No.3Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �40°C40,000 rpm

    145,966 xg

    81.6 mm

    1.5ml

    11 x 38

    11 x 37.5

    2.0ml

    11 x 38

    11 x 37.5

    Ultra 4.0Max. RPM : 30,000Max. RCF : 82,106 xg

    Ultra 5.0Max. RPM : 40,000Max. RCF : 145,966 xg

    24

    145,966

    81.6

    A10U-12 No.4Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �26°C45,000 rpm

    181,795 xg

    80.3 mm

    10ml

    16 x 67

    12

    181,795

    80.3

    16.5 x 70

    Ultra 4.0Max. RPM : 35,000Max. RCF : 109,975 xg

    Ultra 5.0Max. RPM : 45,000Max. RCF : 181,795 xg

    A13.5U-8 No.5Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �26°C50,000 rpm

    203,197 xg

    72.7 mm

    13.5ml

    16.2 x 78

    8

    203,197

    72.7

    16.5 x 83.5

    Ultra 4.0Max. RPM : 40,000Max. RCF : 130,046 xg

    Ultra 5.0Max. RPM : 50,000Max. RCF : 203,197 xg

    A13.5U-12 No.1Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �26°C50,000 rpm

    242,886 xg

    86.9 mm

    13.5ml

    16.2 x 78

    12

    242,886

    86.9

    16.5 x 82.5

    Ultra 4.0Max. RPM : 40,000Max. RCF : 155,447 xg

    Ultra 5.0Max. RPM : 50,000Max. RCF : 242,886 xg

    A38.5U-6 No.9Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �29°C50,000 rpm

    252,389 xg

    90.3 mm

    38.5ml

    25 x 89

    6

    252,389

    90.3

    25.7 x 92.3

    Ultra 4.0Max. RPM : 40,000Max. RCF : 161,529 xg

    Ultra 5.0Max. RPM : 50,000Max. RCF : 252,389 xg

  • Ultra

    / Hi

    gh S

    peed

    Cen

    trifu

    ge

    42

    A38.5U-8 No.2Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �30°C45,000 rpm

    221,867 xg

    98 mm

    38.5ml

    25 x 89

    8

    221,867

    98.0

    25.8 x 92.3

    Ultra 4.0Max. RPM : 40,000Max. RCF : 175,302 xg

    Ultra 5.0Max. RPM : 50,000Max. RCF 221,867 xg

    A50U-8 No.6Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �30°C40,000 rpm

    177,628 xg

    99.3 mm

    50ml

    28.8 x 107

    8

    177,628

    99.3

    29 x 100.5

    Ultra 4.0Max. RPM : 30,000Max. RCF : 99,916 xg

    Ultra 5.0Max. RPM : 40,000Max. RCF : 177,628 xg

    A94U-6 No.7Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C40,000 rpm

    177,807 xg

    99.4 mm

    94ml

    38 x 102

    6

    177,807

    99.4

    38 x 100

    Ultra 4.0Max. RPM : 30,000Max. RCF : 100,016 xg

    Ultra 5.0Max. RPM : 40,000Max. RCF : 177,807 xg

    A250U-6 No.8Tube Capa.

    DIM. � x L mm

    Tube Type

    Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    boring � x L mmCat.NO.

    Type

    Max. RPM

    Max. RC

    Radius

    Angle Rotor �25°C25,000 rpm

    90,139 xg

    129 mm

    250ml

    60 x 125

    6

    90,139

    129

    60 x 101

    Ultra 4.0Max. RPM : 19,000Max. RCF : 52,064 xg

    Ultra 5.0Max. RPM : 25,000Max. RCF : 90,139 xg

    Angle Rotors (Ultra High Speed Centrifuge)

  • Multipurpose CentrifugeFleta 5 I Union 55R Mu

    lti P

    urpo

    seCe

    ntrif

    uge

  • Mul

    tipur

    pose

    Cen

    trifu

    ge

    44

    Multipurpose Centrifuge

    Fleta 5

    Multipurpose bench top centrifuge for labs in hospitalsand universities.

    5,500 5,411 15mlX 32

    Air from the upper side of chamber makes air flow optimized. BLDCMotor(Brushless motor) minimizes noise and vibration (under 60db).

    Worried about noise?

    Motor driving system optimizing: Speedy and smooth acceleration anddeceleration makes stable separation.

    Still waiting the result?

    Multipurpose Centrifuge

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Accel/Decel

    Motor

    Power supply

    Dimension

    Weight, Kg

    5,500rpm

    5,411 xg

    15ml x 32

    99hrs 59min 59sec

    RPM, RCF, Time, Program,Accel/Decel Time, Rotor Number, Rotor Radius

    10 step

    BLDC Motor 700w

    110V/220V, 60Hz, single phase

    570W x 475D x 325H/mm

    40Kg

    Features �Easy and speedy operation and correction by volume knob�Graphic LCD display�Various tube adapters�Design saving working space�Highly efficient BLDC motor�10 levels of Accel./Decel. is suitable for separation of sensitive layers�Automatic RPM/RCF calculating system�Memory function setting the condition of test

    HBTM-5(HSR-4S)

    HBT15-8(HSR-4S)

    HM-2

    Simple and elegant Black &Chrome display channel

    Optimized chamber for effectiveair circulation.

    �Please note that technical specifications subject to change.

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    45

    Mul

    tipur

    pose

    Cent

    rifug

    e

    Multipurpose

    Refrigerated centrifuge

    Multipurpose Centrifuge

    Union 55R

    Multipurpose refrigerating floor type centrifuge generally used forlabs in hospitals and universities on reasonable price level.

    Environmentally refrigerating system of cfc-free and efficient cooling.

    Powerful AC Motors & Cooling System

    Easily moveable type of floor standing

    Tubes of various volumes

    -10�C to+40�C

    5,500 5,411 15mlX 32

    Swingout rotor

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Warning display

    Temp

    Accel/Decel

    Motor

    Power supply

    Dimension

    Weight, Kg

    5,500rpm

    5,411 xg

    15ml x 32

    9hrs 59min 59sec

    RPM, RCF, Time,Temp, Program, Accel/Decel Rotor

    Number, Rotor Radius

    Imbalance, Door open, Over speed, Over temp

    -10 �C~ 40 �C

    3 step

    AC Induction Motor

    110V/220V, 60Hz, single phase

    570W x 475D x 325H/mm

    122Kg

    HBTM-5(HSR-4S)

    HBT15-8(HSR-4S)

    HM-2

    �Please note that technical specifications subject to change.

    Features �One chip Microprocessor control�Easy-to-use control �Environmentally refrigerating system of cfc-free and efficient cooling�RPM/RCF auto calculating�Feedback control system�Brushless AC Induction motor �Memory for saving experiment condition�Temperature control system for delicate experiment

  • Air-flow structure – Fleta 5

    Fleta 5

    Control Display�Customized key pad (Easy operation and correction)�10 steps for acceleration and deceleration for delicate liquid experiment�RPM/RCF auto calculating�Changing term of timer during operation�Rotor Radius 0.1mm setting�Memory for saving experiment condition [100 memories]M

    ultip

    urpo

    se C

    entri

    fuge

    46

    �Inducing inflow and outflow of air in order to minimizeinfluence by air friction during rotation. Effective noisereduction, excellent cooling effect.

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    47

    Mul

    tipur

    pose

    Cent

    rifug

    e

    Multipurpose Centrifuge Accessories

    HSR-4S

    Type

    Max. RPM

    Max. RCF

    Radius

    Dim. for

    Swing Rotor �90°C

    5,500 rpm

    6,131 xg

    181.3 mm

    Fleta 5 / Union 55R

    Tube Capacity (ml)

    Dimensions � x L mm

    Tube Type

    3

    10 x 60

    20

    80

    1,651

    164.1

    3,000

    10 x 55

    White

    HTR-1

    10 x 140

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    5

    11 x 75

    14

    56

    1,651

    164.1

    3,000

    11 x 55

    Green

    HTR-2

    11 x 140

    10

    13 x 100

    12

    48

    1,651

    164.1

    3,000

    13 x 55

    Red

    HTR-3

    13 x 140

    15(16)

    18 x 99.3

    8

    32

    1,651

    164.1

    3,000

    18 x 55

    Blue

    HTR-4

    18 x 140

    15

    17 x 120

    4

    16

    3,089

    172.7

    4,000

    18 x 99.5

    STS

    HBT15-4C

    18 x 149

    15(16)

    18 x 99.3

    8

    32

    2,910

    162.7

    4,000

    18 x 89.5

    STS

    HBT15-8

    18 x 139

    50

    30 x 115

    1

    4

    5,148

    184.2

    5,000

    315 x 115.9

    AL

    HBT50-1C

    31.5 x 161

    50

    29 x 104

    1

    4

    6,131

    181.3

    5,500

    30 x 99

    STS

    HBT50-1

    30 x 158

    50

    29 x 104

    2

    8

    5,067

    181.3

    5,000

    30 x 99

    STS

    HBT50-2

    30 x 158

    Fleta 5 (Dim. 222.5x222.5x42mm)Max. RPM : 5,500 Max. RCF : 6,131 xg

    Union 55R (Dim. 222.5x222.5x48mm)Max. RPM : 4,000 Max. RCF : 3,470 xg

    HBTM - 5

    Type

    Max. RPM

    Max. RCF

    Radius

    Rack Holder

    3,000 rpm

    1,681 x g

    167.1 mm

  • Mul

    tipur

    pose

    Cen

    trifu

    ge

    48

    HM-2

    Type

    Max. RPM

    Max. RCF

    Radius

    Dim. for

    Swing Rotor �90°C

    2,000rpm

    631 xg

    181.3 mm

    Fleta 5 / Union 55R

    Tube Capacity (ml)

    Dimensions � x L mm

    Tube Type

    MTP

    128 x 85.6 x 15

    2

    631

    141.0

    2,000

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    Cell Culture

    128 x 85.6 x 21

    2

    631

    141.0

    2,000

    DWP

    128 x 85.6 x 45

    2

    631

    141.0

    2,000

    Fleta 5 Max. RPM : 2,000 Max. RCF : 631 xg Union 55R Max. RPM : 2,000 Max. RCF : 631 xg

    Separation pattern for rotor type

    Swing Rotor Fixed Angle Rotor

    90�C rotation (swing complete)

    45�C rotation (swinging)

    standstill�Centrifugal force affect sto the bottom of tube due to

    90�Ctube lac rotation so that consecutive separationoccurs without separation layer

    �Normal rotation result �Rotation complete (Layersget mixed when it stopsdue to gravity)

    In case of hemocyte, It mayoccur low separation efficiencyby blending layers

  • Blood Bag CentrifugeComponent 12R I Component R B

    lood

    Bag

    Cent

    rifug

    e

  • Bloo

    d Ba

    g Ce

    ntrif

    uge

    50

    Specialized blood-bag treating centrifuge with bucket styleof big capacity, 2,400 ml swing-out rotor.

    Blood-bag

    Separating Centrifuge

    Blood Bag Centrifuge

    -10�C to+40�C

    4,800 7,212 2,400mlX 6

    10steps for acceleration and deceleration can be selected for delicateliquid experiment.

    Stable Sampling

    Eco-friendly and effective cooling with CFC Free freezing system.

    Eco-friendly cooling system

    Micro Soft Control make good progress on separating layers by minimizingvibration section.

    Want perfect blood separation?

    Component12R

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Accel/Decel

    Temp

    Motor

    Power supply

    Dimension

    Weight, Kg

    4,800 rpm

    7,212 xg

    2,400ml x 6

    99hrs 59min 59sec

    RPM, RCF, Time, Temperature,Program, Accel/Decel,

    Rotor Number, Rotor Radius

    10 step

    -10 �C~ 40 �C

    AC Induction Motor

    220V, 60Hz, single phase

    840W x 980D x 970H/mm

    520Kg

    Features �Graphic LCD�Fast and easy operation and correction by Key Pad �Big capacity 2,400 ml Swing-out rotor of bucket style�Soft & silent operation�Memory function for setting the condition of test�Environmentally refrigerating system of cfc-free�Automatically calculating RPM/RCF�10 steps for acceleration and deceleration can be selected for delicate liquid

    experiment�Efficient cooling system�Wind shield minimizing air resistance�Specially designed for separating blood platelet in blood bank and hospital

    or the treatment of big capacity

    WS2400-6B

    �Please note that technical specifications subject to change.

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    51

    10steps for acceleration and deceleration can be selected for delicateliquid experiment.

    Stable Sampling

    Eco-friendly and effective cooling with CFC Free freezing system.

    Eco-friendly cooling system

    Centrifuge for

    Large Size Sample

    Blood Bag Centrifuge

    Component R

    Big size refrigerating centrifuge for blood-bag orvarious tubes.

    -10�C to+40�C

    5,000 7,217 1,000mlX 6

    Blo

    od B

    agCe

    ntrif

    uge

    Description Specification Remarks

    RPM

    RCF

    Max. capacity

    Time

    Display

    Accel/Decel

    Temp

    Motor

    Power supply

    Dimension

    Weight, Kg

    5,000 rpm

    7,217 xg

    1,000ml x 6

    99hrs 59min 59sec

    RPM, RCF, Time, Temperature,Program, Accel/Decel,

    Rotor Number, Rotor Radius

    10 step

    -10 �C~ 40 �C

    AC Induction Motor

    220V, 60Hz, single phase

    700W x 807D x 858H/mm

    380Kg

    WS1000-6B Optimized chamber foreffective cooling

    Features �Graphic LCD�Fast and easy operation and correction by Key Pad �Swing-out rotor of big capacity of 1,000 ml, bucket style�Soft & silent operation�Memory function for setting various conditions�Environmentally refrigerating system of cfc-free�Automatic RPM/RCF calculating system�10 levels of Accel./Decel. is suitable for separation of sensitive layers�Efficient cooling system�Wind shield minimizing air resistance�Specially designed for separating blood platelet in blood bank and hospital

    or the treatment of big capacity

    �Please note that technical specifications subject to change.

  • Bloo

    d Ba

    g Ce

    ntrif

    uge

    52

    Component R /12RControl Display�Customized key pad (Easy operation and correction)�10 steps for acceleration and deceleration for delicate liquid experiment�RPM/RCF auto calculating�Changing term of timer during operation�Time set up, max. 99 hours 59 minutes 59secs�Rotor Radius 0.1mm setting�Memory for saving experiment condition [100 memories]

    WS2400-6B Wind shield

    Type

    Max. RPM

    Max. RCF

    Radius

    Dim. for

    Swing Rotor �90°C

    4,800 rpm

    7,470 x g

    290mm

    494x434x120

    Tube Capacity (ml)

    Dimensions � x L mm

    Tube Type

    250

    2

    12

    7,212

    280

    4,800

    White

    TB-250

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    450

    2

    12

    7,212

    280

    4,800

    White

    TB-450

    500

    2

    12

    7,212

    280

    4,800

    White

    TB-500

    Component 12R Max. RPM : 4,800 Max. RCF : 7,470 xg

    B2400

    Blood Bag Bucket2,400ml capacity

  • HANI

    L SC

    IENC

    E IN

    DUST

    RIAL

    53

    WS1000-6B Wind shield

    Type

    Max. RPM

    Max. RCF

    Radius

    Dim.

    Swing Rotor �90°C

    5,000 rpm

    7,217 xg

    225.1 mm

    333.7 x 362 x 55 mm

    Tube Capacity (ml)

    Dimensions � x L mm

    Tube Type

    5

    12 x 75

    26

    156

    10,202

    253.5

    6,000

    13 x 70

    Magenta

    T5-26

    13 x 187.5

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    10

    13 x 100

    26

    156

    10,171

    252.7

    6,000

    14 x 89.5

    Yellow

    T10-26

    14 x 186.5

    15

    16 x 114

    19

    114

    10,215

    253.8

    6,000

    17 x 99.5

    Green

    T15-19

    17 x 185

    50

    29 x 104

    7

    42

    9,877

    245.4

    6,000

    29.2 x 81

    White

    T50-7

    29.2 x 179.5

    250

    61.8 x 123

    1

    6

    10,275

    255.3

    6,000

    62.2 x 99

    Cyan

    T250-1

    62.2 x 189

    500

    69.5 x 170.2

    1

    6

    10,259

    254.9

    6,000

    75.5 x 99

    Violet

    T500-1

    75.5 x 189

    1,000

    97 x 152

    1

    6

    10,312

    256.2

    6,000

    96 x 153

    Chartreuse

    T1000-1

    96 x 190

    50

    30 x 115

    5

    30

    10,159

    252.4

    6,000

    29.5 x 99.5

    Blue

    T50-5C

    17 x 86

    15

    17 x 120

    14

    84

    10,066

    250.1

    6,000

    17 x 89

    Sky Blue

    T15-14C

    13 x 184

    480

    1

    6

    9,990

    248.2

    6,000

    -

    Black

    -

    -

    50

    5

    30

    7,506

    186.5

    6,000

    27 x 65

    Black

    TS50-5

    27 x 90

    30

    180

    9,897

    245.9

    6,000

    13 x 55

    Crimson

    T5-30

    13 x 180

    Adapter

    Tube per Adapter

    Tube per Rotor

    Max.RCF

    radius (mm)

    RPM

    boring � x L mm

    Color / Material

    Cat.NO.

    Max. length � x L mm

    24

    144

    9,897

    245.9

    6,000

    13.5 x 80

    Yellow

    T10-24

    13.5 x 180

    17

    102

    9,897

    245.9

    6,000

    17.3 x 80

    Green

    T15-17

    17.3 x 180

    4

    24

    9,897

    245.9

    6,000

    29 x 80

    White

    T50-4

    29 x 180

    1

    6

    9,897

    245.9

    6,000

    62 x 80

    Red

    T250-1

    62 x 180

    1

    6

    9,897

    245.9

    6,000

    74 x 80

    Blue

    T500-1

    74 x 180

    B1000

    Round Bucket1000ml capacity

    Component R Max. RPM : 5,000 Max. RCF : 7,217 xg

    Swing Rotors

    Blo

    od B

    agCe

    ntrif

    uge

  • Bloo

    d Ba

    g Ce

    ntrif

    uge

    54

    Centrifuge Theory

    RotorsIt is the method to indicate the relative centrifugal force by thefollowing equation according to centrifugal speed of rotor (rpm). The reason to use rpm instead of the relative centri-fugal force is tomeasure each speed precisely with motor speed per minute (N, rpm) asit is very difficult to measure its speed by the relative centrifugal force.

    K-FactorAnother variable of the rotor is K-Factor. K-Factor is used for predictingthe experiment time of the best suited. For example, the rotor’s K-Factor without shielding is 402. At that time, the speed is 2,000 rpmand it is indicated the time to need in separating from the maximumspeed is t=402/100=4.02 hour=4 hour 1 minute.The main reason to use K-Factor is that each rotor has different RCFand also the RCF is different even the material are same on thedifferent location. As it has different value by the materials speed and sedimentationdistance, K-Factor is used to make same value after make calibration.See Picture 1 It means K-Factor is used to make fixed value not relatedwith each speed and sedimentation distance. K-Factor is only affectedby the speed of the rotation.

    The time prediction of centrifugal separationIf the sedimentation factor is known, the required time to do pellet is

    predicted by using the following equality t=k/s ( t: operating time, k-K-

    Factor, s=Sedimentation Factor )

    When the user make separation of materials which have same

    sedimentation factors with different rotors, the separating time is

    reduced in case he use the rotor which has smaller K-Factor. In

    addition, the user can predict the pellet time with using different rotors

    with the above equality when the use has to make centrifugal

    separation with using various rotors unavoidably.

    For example, how many time is required to make separation in

    condition of angle rotor 20,000rpm comparing that it takes 4 hours to

    make separation with using the swing rotor’s speed 40,000rpm?

    Every rotor has the different K value and user can get the Required K

    value with the calculating equality t=k/s. therefore, K value in the

    condition of swing rotor is 370 and the value in angle rotor

    20,000rpm is 125. it can be calculated and solved by following

    proportional expression. 370:4=125:X. X=1.35 hours So, the user can

    get predicted time to make separation as like the above.

    Effectiveness of Gross Centrifugal ForceEffectiveness of Gross Centrifugal Force is an integral calculus to each

    speed by the time. This effectiveness is required to make same result

    for the experiment even every machine has the different time for

    acceleration and speed reduction.

    It is the gross area of the red colored part. See Picture 2 the main

    purpose to use this effectiveness is to make calculation objectively

    from the subjective calculation which get different of the Effectiveness

    of Gross Centrifugal Force by different centrifuges.

    Therefore, the user can make operation in convenience the other

    centrifuges to get same result after using the one centrifuge. The each

    speed is calculated by following equality.

    Relative Centrifugal Force (R.C.F)It is indicated the power which the factor takes regarding tocentrifugal speed and indicated by the ratio comparing the power ofthe gravity to the power which the factor takes. It means the relativecentrifugal force (RCF) is indicated as a ratio comparing the powerwhich the factor takes in the condition of centrifugation to the force ofgravity. The main factors to determine RCF are the distance of the particlefrom the axis of rotation, each speed of rotation (RPM) and the gravityacceleration (980cm/sec). RCF is proportional to the square of the speed so RCF increases 4times of the speed when the speed increases 2 times. The main reasonto use RCF instead of ACF (Absolute Centrifugal Force) can adopt allparticles’ mass. In case of using ACF.It is difficult to adopt all particle’s mass as centrifugal force is increasedaccording to increase the particle’s mass. This is indicated and expressed by xg and xg means it is not related onthe particle’s mass. In case of calculating the particle’s mass at thesame time, It is the particle’s centrifugal force. But, RCF is affected byits location even the materials are both of same. The main factor is thedistance of the particle from the axis of rotation. For example, the RCFto the particle located in the most near of the axis is smaller than theparticle located in the most far of the axis. They are called rmin formost near location and rmax for most far location.

  • Medical CentrifugeMF 300 I MF 80 I MF 50 I HA 12 I HA 200

    Cellspin I Serospin I HA 400

    Med

    ical

    Cen

    trifu

    ge

  • Med

    ical

    Cen

    trifu

    ge

    56

    General Centrifuge

    Medical Centrifuge

    MF 300Basic multipurpose bench top centrifuge for labs in hospitals and universities.

    �Please note that technical specifications subject to change.

    4,000 2,898 15mlX 24

    MF 804,000 2,469 15mlX 12

    Max. RPM

    Max. RCF