Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
1
Contents 1 System documentation 3 1.1 Documentation overview 4 1.2 Online help system 8 2 System functions 9 2.1 Transmission wavelengths 10 2.2 Optical Multiplexing Scheme 14 2.3 Amplification scheme 48 2.4 Dispersion compensation scheme 64 2.5 Transponder, Muxponder, and Regenerator Functions 67 2.6 hiT7300 Optical Protection 89 2.7 System management Function 96 3 SURPASS hiT7300 NE Types 127 3.1 Optical Line Repeater (OLR) Network Element 130 3.2 Optical Network Node (ONN) 132 3.3 SON – Standalone Optical Node 156 4 CWDM support 161 4.1 Passive CWDM Filter Pack Solutions 164 4.2 CWDM Filter Architecture 166 4.3 CWDM Topologies 168 5 Hardware design 169 5.1 hiT7300 racks 170 5.2 hiT7300 Sub-racks 172 5.3 RMH07 series Sub-Rack 182 5.4 Mechanical design of modules 184 5.5 SURPASS hiT7300 optical cabling 188 6 Exercise 191
Hardware & Functionality
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 2
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
3
1 System documentation
System documentation
Fig. 1 System documentation
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 4
1.1 Documentation overview The documentation of the SURPASS 7300 comprises the following descriptions and manuals:
TIP The documentation is available on CD-ROM.
Environmental Product Declaration (EPD) The purpose of this document is to provide environmentally relevant information of a specific Nokia Siemens Networks product.
This document shall not be interpreted as a specification, modification or amendment to the specification, or additional or other warranty of any kind. In case of discrepancy between this document and the Product specification or terms and conditions of the valid supply agreement between Nokia Siemens Networks and the customer, the supply agreement and Product specification shall always prevail over this document.
Product Description (PD): The Product Description (PD) provides an overview of the entire system. PD includes description of features, components application, performance features, NE types, operating theory, block diagrams, plug-in card descriptions, and detailed technical specifications.
Installation and Test Manual (ITMN): The Installation and Test Manual ITM contains instructions on how to install the SURPASS hiT7300 system components. This includes mounting the sub-racks in the equipment racks, connecting and testing power cables, electrical cabling and plug-in card installation. The ITM also includes the post-installation Commissioning procedures.
Optical Link Commissioning (OLC): This document gives the instructions for performing post-installation turn-up and link optimization procedures and describes the standard optical link commissioning procedure for SURPASS hiT7300 system.
OLR and ONN Commissioning (ONN / OLR COMM): This document contains instructions for commissioning of OLR and ONN network elements and described commissioning process of taking installed OLR or/and ONN and bringing them to an operational state.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
5
EPD
Documentation on CD-ROM (PDF format)Documentation on CD-ROM (PDF format)
ITMN
ONN / OLRCommissioning
SONCommissioning
OLCOMN
TSMN
ICMA
PD
LSS
CD-ROM Content, PDF, Order Number: A42022-L5972-E010-02-76K5
SI
Fig. 2 User Manuals on CD-ROM
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 6
SON Commissioning (SON-COMM): This document contains instructions for commissioning of SON network element and described commissioning process of taking an installed SON and bringing it to an operational state.
Open Source Licenses (OSL): List of used open source software licenses.
Operating Manual (OMN): The Operating Manual (OMN) provide information on how to operate, monitor and maintain the SURPASS hiT7300 system via Element Manager (EM) of the Local Craft Terminal (LCT), principles of alarming and HW upgrade procedures. The Element Manager (EM) is an easy-to-use Graphical User Interface (GUI) with extensive Online Help.
Trouble Shooting Manual (TSMN): The Trouble Shooting Manual TSMN deals solely with alarm handling and trouble shooting. In the TSMN is obtainable detailed information to troubleshoot and remedy alarm events. This document describes troubleshooting procedures to be performed in reaction to alarm events generated in the SURPASS hiT7300 system.
Interconnect, Configuration, and Mechanical Assembly (ICMA): This document deals with the electrical and optical cabling of the sub-racks and racks; it illustrates the rack equipment of the several variants and contains block diagrams and cabling lists, additionally it describes the installation and cabling for the SURPASS hiT7300 system. ICMA contains complete set of drawings that depict rack, sub-rack, and plug-in card arrangements, as well as electrical and fiber cabling plans.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
7
Customer Documentation overviewCustomer Documentation overview
EPD
ITMN
OLC
OL
R &
ON
N
Co
mm
issi
on
ing O
MN
LSS
SO
N
Co
mm
iss
ion
ing T
SMN
OLC
SON
ICMA
PD
Fig. 3 Customer Documentation
EPD Environmental Product Declaration ICMA Interconnect, Configuration and Mechanical Assembly ITMN Installation and Test Manual LSS Long Single Span Architecture User Manual NE_COMM OLR and ONN Commissioning NE_COMM_SON SON Commissioning OLC Optical Link Commissioning OLC_SON Optical Link Commissioning SON
OMN Operating Manual
PD Product Description TSMN Troubleshooting Manual
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 8
1.2 Online help system There is possible to use the online help system that is provided with the NE software to receive information about all the window contents and menus. The Contents, Index and Find buttons enable the online help to be searched quickly and conveniently. You may also display essential steps of important operating sequences via the help table of contents. Individual help topics can be printed, and context-sensitive help texts called up directly from the user interface.
Fig. 4 Online help system
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
9
2 System functions
System functions
!
Fig. 5 System functions
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 10
2.1 Transmission wavelengths The SURPASS hiT 7300 supports 40-channel (with 100 GHz frequency spacing) and 80/96-channel (with 50 GHz frequency spacing) DWDM transmission systems within the C band. The use of a 40-channel or an 80/96-channel plan depends of the customer’s needs and network application.
The 40-channel frequency/wavelength plan allows a very flexible network design for various End-of-Life (EOL) optical channel counts from 4 to 40 channels in steps of 4 channel sub-bands. These frequencies/wavelengths are also referred to as standard frequency grid.
SURPASS hiT 7300 80/96-channel DWDM transmission system is using 80 or 96 channels in the C-Band with 50 GHz of channel spacing. These frequencies/wavelengths are created by the combination of the 40/48-channel standard frequency grid with the interleaved set of a 40/48-channel offset frequency grid.
TIP The 80/96-channel frequency/wavelength plan is not divided into a 4-channel sub-band structure (as the 40-channel frequency/wavelength plan).
λ[nm]
0.8 nm (100 GHz)
„Blue Band“ „Red Band“
Sub-bandsSub-bands
196.00 (THz) 1529,55 (nm)
196.00 (THz) 1529,55 (nm)
C01
192,1 (THz) 1560,61 (nm)
192,1 (THz) 1560,61 (nm)
40 channels in C-Band: standard frequency grid40 channels in C-Band: standard frequency grid
C02 C03 C04 C05 C06 C07 C08 C09 C10
„Middle Band“
hiT7300 Transmission WavelengthsEOL 40 channels
Fig. 6 Transmission wavelengths for EOL 40 channels
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
11
λ[nm]
0.8 nm (100 GHz)
EOL 80 channels:196.00 THz
EOL 96 channels:196.10 THz
EOL 80 channels:196.00 THz
EOL 96 channels:196.10 THz
EOL 80 channels:192.10 THz
EOL 96 channels: 191.40 THz
EOL 80 channels:192.10 THz
EOL 96 channels: 191.40 THz
40 or 48 channels in C-Band: standard frequency grid40 or 48 channels in C-Band: standard frequency grid
hiT7300 Transmission WavelengthsEOL 80 or 96 channels
λ[nm]
0.8 nm (100 GHz)
EOL 80 channels:195.95 THz
EOL 96 channels:196.05 THz
EOL 80 channels:195.95 THz
EOL 96 channels:196.05 THz
EOL 80 channels:192.05 THz
EOL 96 channels: 191.35 THz
EOL 80 channels:192.05 THz
EOL 96 channels: 191.35 THz
40 or 48 channels in C-Band: offset frequency grid40 or 48 channels in C-Band: offset frequency grid
0.4 nm (50 GHz)
Fig. 7 Transmission wavelengths for EOL 80 or 96 channels
40ch offset frequency100GHz grid.
λ[nm]
InterleaverInterleaver
λ[nm]
40ch standard frequency100GHz grid.
80ch 50GHzfrequency grid.
0.8 nm (100 GHz) 0.4 nm (50 GHz)
hiT7300 Transmission Wavelengths
Fig. 8
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 12
The 40 channel frequency/wavelength plan allows for very flexible network design for various End-of-Life (EOL) optical channel counts from 4 channels up to 40 channels in steps of 4 channel sub-bands.
The 40 channel SURPASS hiT7300 system uses a maximum of 40 wavelengths within the C-band, with 100 GHz frequency spacing starting with 1529.55 nm and ending with 1560.61 nm and divided into following groups:
• 16 “blue” wavelengths (C01 to C04 sub-bands).
• 8 “middle” wavelengths (C05 and C06 sub-bands).
• 16 “red” wavelengths (C07 to C10 sub-bands).
All MUX/DMUX cards have fixed wavelength assignment to their physical channel ports. Both thin-film filter for realizing flexible subband structures and arrayed wave-guide (AWG) optical filter technology for full-access to 40-channel frequency grids are available, thereby always meeting cost-effective solutions for each network application. The cards are highly reliable and mostly consisting of passive optical components only.
TIP The same MUX/DMUX cards are used for ONN terminal applications as well as for all OADM and PXC applications.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C01C03C04C05C08C10 C06 C02C07C09
C01
C03
C05
C07
C09
C02
C04
C06
C08
C10
40 channels overall (192.1 … 196.0 THz)
No band gap
Optical Channel GroupsOptical Channel Groups
Fig. 9 Optical Channel Groups
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 14
2.2 Optical Multiplexing Scheme The choice and structure of the optical multiplexing technology for hiT7300 takes into consideration several factors such as the channel granularity requirements, modularity, and subsequent upgradeability. The optical Mux/Demux cards offer very low insertion loss to facilitate links with a large number of ONN’s as well as to support ONN’s without booster amplifier wherever possible in order to reduce the overall system cost.
SURPASS hiT 7300 supports 40 wavelengths out of the 100 GHz wavelength grid and 80/96 wavelengths out of the 50 GHz wavelength grid according to ITU-T G.692/G.694.1.
The Mux/Demux cards have fixed wavelength to physical port assignment. The cards are highly reliable consisting of the passive optical components including only the electrical components necessary for the card identification. All Mux/Demux cards used for Flexible Terminal/OADM are bidirectional cards, where Mux/Demux cards for FullAccess Terminal/OADM are 40-channel unidirectional or 48-channel bidirectional cards.
TIP The same Mux/Demux cards are used for the ONN terminal application as well as for the ONN OADM application.
TIP Cards are bidirectional, only DEMUX direction is shown.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
15
Terminal based on 4- channel sub-bands
• Flexible pay as you grow approach with modular architecture, 4 channel steps
• In service upgrade up to 40 channels end of life
Terminal based on AWG
• Full access to 40 channels from day 1
• 40-ch AWG and 4-ch group filters can be mixed in the network
• Upgrade to 80 channels with add. interleaver and off-set grid AWG
Band Filter
4 Channel Filter
AWG – 40 channel
Arrayed Waveguide
Grating
...
...
Both fixed filter options – banded and AWG –are fully interoperable
Sub-band filter and AWG filter optionsfor 40 channel terminals
Fig. 10 Optical Multiplexing Scheme- Flexible / AWG
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 16
2.2.1 Flexible Filter structure (cascaded filters)
The filter cards act as multiplexers/demultiplexers by providing the primary wave division or aggregation of all the transponder signals and allowing access (add/drop) to a particular wavelengths or set of wavelengths.
For realizing flexible sub-band structures for multiplexing/demultiplexing of up to 40 channels in standard frequency grid (C-band) with 4-channel granularity there are only 4 types of MUX/DMUX cards needed, which are already supported since R4.0 of hiT 7300:
Optical Multiplexer/Demultiplexer Cards for flexible sub-band structures
Card function Card name
Red/blue splitter + 2x sub-band multiplexing (bidirectional)
F08SB
4x sub-band multiplexing (bidirectional) F16SB (red and blue band variant)
1x sub-band filter + 4-channel multiplexing (bidirectional)
F04MDU (10 sub-band variants)
4-Channel multiplexing (bidirectional) F04MDN (10 sub-band variants)
Fig. 11 Optical Multiplexer/Demultiplexer Cards
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
17
2.2.1.1 F04MDN-1 Filter Cards
The F04MDN-1 card consists of one four channel fixed filter. The card is bidirectional and occupies a single slot. F04MDN-1 is offered in ten different variants (subbands C1-C10) to cover the entire 40 channel wavelength plan.
Fig. 12 F04MDN-1 Filter Cards and F04MDU-1 Filter Cards
2.2.1.2 F04MDU-1 Filter Cards
The F04MDU-1 card consists of one band filter and one corresponding four channel fixed filter. The card is bidirectional and occupies a single slot. It is offered in ten different variants (subbands C1-C10) to cover the entire 40 channel wavelength plan.
Fig. 13 HW Layout
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 18
2.2.1.3 F08SB-1 Filter Card
The F08SB-1 card consists of a red/blue filter and two band filters. The card is bidirectional and occupies a single slot. It offers two band filters for subbands C5 and C6 and a red/blue filter that separates subbands C1-C4 from subbands C7-C10. There is only one variant of this card.
Fig. 14 F08SB-1 Filter Card
2.2.1.4 F16SB-1 Filter Cards
Each F16SB-1 card consists of four cascaded band filters. The card is bidirectional and occupies a single slot. It is offered in two variants for subbands C1-C4 (blue band) and subbands C7-C10 (red band), respectively.
Fig. 15 F16SB-1 Filter Cards
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
19
Fig. 16 HW layout
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 20
2.2.2 Fixed Filter structure (AWG filter)
For realizing 40-channel (EOL) systems in standard and offset frequency grid (C-band) with full access to all channels from day 1 (BOL), and for 80 or 96-channel systems the following MUX/DMUX cards are supported in hiT 7300:
Optical Multiplexer/Demultiplexer Cards for 40/80-channels full access scheme
Card function Card name
40-channel unidirectional multiplexing/demultiplexing for 100GHz Standard frequency grid or Offset frequency grid
F40/S or /O
40-channel unidirectional multiplexing/demultiplexing and per channel VOA's for 100GHz Standard frequency grid or Offset frequency grid
F40V/S or /O
40-channel multiplexing for 100GHz frequency grid, per channel monitor diodes, /S and /O
F40MP/S or /O
40-channel multiplexing for 100GHz frequency grid, per channel monitor diodes and VOAs, /S and /O
F40VMP/S or /O
80-channel split coupler and drop interleaver (unidirectional) F80DCI
80-channel interleaver (bidirectional) F80MDI
Optical Multiplexer/Demultiplexer Cards for 96-channels full access scheme
Card function Card name
48-channel unidirectional multiplexing and demultiplexing for 100GHz Standard frequency grid
F48MDP/S
48-channel unidirectional multiplexing and demultiplexing for 100GHz Offset frequency grid
F48MDP/O
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
21
Fig. 17 Optical Multiplexer/Demultiplexer Cards of EOL 40/80 channels
Fig. 18 Optical Multiplexer/Demultiplexer Cards of EOL 96 channels
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 22
2.2.2.1 F40-1/S and F40-/O Filter Cards
Each F40-1/x filter cards consist of a 40-channel fixed filter based on temperature-controlled arrayed waveguide grating (AWG) technology, which performs multiplexing or demultiplexing of 40 channels in 100 GHz spaced standard frequency grid (F40/S) or 100 GHz spaced offset (50 GHz shifted) frequency grid (F40/O), respectively. The F40-1/x card is unidirectional and performs either an optical multiplexing or demultiplexing.
F40-1/S
λ1 λ2 λ40
.
...
F40-1/S
λ1 λ2 λ40
.
...
Multiplexer Card Demultiplexer Card
F40-1/O
λ41 λ42 λ80...
F40-1/O
λ41 λ42 λ80...
Multiplexer Card Demultiplexer Card
Fig. 19 F40-1/x Filter Cards
Fig. 20 HW Layout
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
23
2.2.2.2 F40V/S and F40V/O Filter Cards
The F40V-1/x card consists of a 40-channel fixed filter based on temperature-controlled AWG technology. The F40V-1/x performs multiplexing or demultiplexing of 40 channels in 100 GHz spaced standard frequency grid (F40V-1/S) or 100 GHz spaced offset (50 GHz shifted) frequency grid (F40V-1/O), respectively. In addition to multiplexing/demultiplexing each F40V-1/x contains a Variable Optical Attenuator (VOA) for each individual input/output channel. The VOAs are used in the optical channel power pre-emphasis (in case the F40V-1/x card is used as multiplexer) or drop channel power adjust (in case the F40V-1/x card is used as demultiplexer), therefore allowing a very compact and cost-effective solution with high channel count while, achieving highly automated network commissioning at the same time.
The F40-1V/x card is unidirectional and performs either an optical multiplexing or demultiplexing like the F40/x each F40V/x card provides 41 optical front connectors within 21 duplex LC/PC connectors on the front panel for access to all 40 channel ports and the aggregation port, it occupies 2 slots (2x 30mm).
Multiplexer Card Demultiplexer Card
Multiplexer Card Demultiplexer Card
λ1λ2λ40 ... λ1λ2λ40 ...
λ41λ42λ80 ...λ41λ42λ80 ...
F40V-1/S F40V-1/S
F40V-1/O F40V-1/O
Fig. 21 F40V/S and F40V/O Filter Cards
TIP When used as a demultiplexer, an optical input power monitor is provided for detection of loss-of-signal and laser safety control.
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 24
2.2.2.3 F48MDP-1/S and F48MDP-1/O Filter Cards
The F48MDP-1/x card consists of a 48-channel fixed filter based on AWG technology. The F48MDP-1/x is a bidirectional card that performs multiplexing or demultiplexing of 48 channels in spaced standard frequency grid (F48MDP-1/S) or spaced offset (50 GHz shifted) frequency grid (F48MDP-1/O).
The input port of the demultiplexing incorporates a monitor diode for LOS detection and signaling to Laser Safety bus and to Fault-Management. The demultiplexer has a monitor point for service and optional MCP access.
The multiplexing part of the card has in each input port, monitors for Automatic Port Connection Detection (APDC), power level measurement and LOS detection.
Fig. 22 F48MPD-1/x Filter Cards
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
25
Fig. 23 HW Layout
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 26
2.2.3 Wavelength-Selective Switch Cards
The filter cards act as multiplexers/demultiplexers by providing the primary wave division or aggregation of all the transponder signals and allowing access (add/drop) to a particular set of wavelengths from an optical fiber while passing the remaining wavelengths. Line side wavelengths require translation to client side equipment via the transponder card.
The following Wavelength-Selective Switch cards are supported in hiT 7300:
Wavelength-Selective Switch Cards
Card name Usage Optical multiplexer of
Architecture Communication
type
F40MR-1 a ROADM PLC-WSS Bidirectional
F02MR-1 an ONN-R2 MEMS-WSS Bidirectional
F08MR-1 reconfigurable PXC MEMS-WSS Bidirectional
F06DR80-1 Optical demultiplexer of a reconfigurable PXC
MEMS-WSS Unidirectional
F06MR80-1 a reconfigurable PXC MEMS-WSS Unidirectional
F09DR80-1 Optical demultiplexer of a reconfigurable PXC
PLC-WSS Unidirectional
F09MR80-1 a reconfigurable PXC PLC-WSS Unidirectional
F09MDRT-1/S an ONN-RT or ONNX Tunable WSS Bidirectional
F09MDRT-1/O an ONN-RT or ONNX Tunable WSS Bidirectional
F09MDR96-1 an ONN-X96 Tunable WSS Bidirectional
O09CC-1 an ONN-X96 Coupler card for color- and directionless PXC
Bidirectional
F80DCI-1 Optical demultiplexer of a ROADM
Interleaver filter and splitter
Unidirectional
F80MDI-1 Optical multiplexer or demultiplexer
Interleaver filters Bidirectional
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
27
BidirectionalTunable WSSan ONN-X96F09MDR96-1
BidirectionalCouple card for colorless and directionless PXC
an ONN-X96O09CC-1
bidirectionalInterleaver filtersOptical multiplexer or demultiplexerF80MDI-1
UnidirectionalInterleaver filter and splitterOptical demultiplexer of a ROADMF80DCI-1
BidirectionalTunable WSSan ONN-RT or ONN-XF09MDRT-1/O
BidirectionalTunable WSSan ONN-RT or ONN-XF09MDRT-1/S
UnidirectionalPLC-WSSa reconfigurable PXCF09MR80-1
UnidirectionalPLC-WSSOptical demultiplexer of a reconfigurable PXC
F09DR80-1
UnidirectionalMEMS-WSSa reconfigurable PXCF06MR80-1
UnidirectionalMEMS-WSSOptical demultiplexer of a reconfigurable PXC
F06DR80-1
BidirectionalMEMS-WSSreconfigurable PXCF08MR-1
BidirectionalMEMS-WSSan ONN-R2F02MR-1
BidirectionalPLC-WSSa ROADM F40MR-1
Communicationtype
ArchitectureUsageOptical multiplexer of …
Card name
Wavelength-Selective Switch Cards
Fig. 24 Wavelength-Selective Switch Cards
X
X
ONN-X96
X
ONN-RT
X
X
X
ONN-RT80
X
ONN-X
X
X
X
X
ONN-X80
F09MDR96-1
O09CC-1
F80MDI-1
XF80DCI-1
F09MDRT-1/O
F09MDRT-1/S
F09MR80-1
F09DR80-1
F06MR80-1
F06DR80-1
XF08MR-1
XF02MR-1
XF40MR-1
ONN-R80ONN-R2ONN-RCard name
Wavelength-Selective Switch Cards
Fig. 25 Wavelength-Selective Switch Cards
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 28
2.2.3.1 F40MR-1
SURPASS hiT 7300 supports wavelength selective switching for building a ROADM providing full access to 40 optical channels. The key component for this application is the F40MR-1 card which includes an integrated Planar Lightwave Circuit-Wavelength Selective Switch (PLC-WSS) with low insertion loss, providing a remotely (via software) reconfigurable optical switching function per individual wavelength.
The input DWDM signal from the line interface (optical pre-amplifier) is split into express traffic and local drop traffic. The express direction provides an optical input power monitor for detection of loss-of-signal and laser safety control.
The output DWDM signal toward the line interface (booster or booster-less interface) of the PLC-WSS, results from a 40-channel multiplexing. These 40 multiplexed channels are individually selectable (via software) between the 40 incoming express channels and the 40 local add channels.
For each optical channel to be transmitted, a VOA and an optical power monitor diode are available.
Fig. 26 F40MR-1 card structure
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fig. 27 F40MR-1 card structure- HW layout
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 30
2.2.3.2 F02MR-1
SURPASS hiT 7300 supports wavelength selective switching for building a cost optimized nodal degree 2 ROADM (i.e., ONN-R2) providing full access to 40 optical channels.
The key component for this application is the F02MR-1 card which includes in the transmission path an integrated 2:1 Micro-Electro-Mechanical System - Wavelength Selective Switch (MEMS-WSS) module, providing a remotely (via software) reconfigurable optical switching function per individual wavelength.
The incoming signals of the cross-connect are switched with the WSS module on the common output which is followed by a booster amplifier. One of the inputs of the WSS is connected to the output of a mux filter where the local add channels are inserted.
In the receiver path, the incoming signal from the pre-amplifier is launched into a 1x2 splitter with a 40/60 splitting ratio. At the higher output port, a demux filter (F40-1/S) can be connected for local drop traffic. The other port is the output of the cross-connect. At both inputs of the WSS and the C-COM port of the splitter, LOS monitors are used for supervision. Also a power monitor is included at the splitter drop output.
Fig. 28 F02MR-1 card structure
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
31
2.2.3.3 F08MR-1
SURPASS hiT 7300 supports wavelength selective switching for building a multi-degree 40-channel PXC providing full access to 40 optical channels. The key component for this application is the F08MR-1 card which includes an integrated 8:1 MEMS-WSS module, providing a remotely (via software) reconfigurable optical switching function per individual wavelength.
The input DWDM signal from the line interface (optical pre-amplifier) is split into 7 crossconnect outputs and 1 local drop traffic output. The drop output also provides an optical input power monitor for detection of Loss Of Signal (LOS) and laser safety control.
The WSS module collects DWDM traffic from 7 other line ports and 1 local add traffic input, and performs arbitrary pass-through switching for any wavelength, of the 8 input ports, toward its output port.
The internal cross-connect traffic ports from different F08MR-1 cards (of different line directions) can be interconnected to allow a configurable pass-through traffic between arbitrary line directions.
Fig. 29 F08MR-1 card structure
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 32
2.2.3.4 F09MDRT-1/S and F09MDRT-1/O
The F09MDRT-1/x is a bidirectional tunable WSS card suitable for ONN-RT and ONNRT80 configurations.
Each drop channel of the WSS is tunable and remotely configurable. The F09MDRT-1/x contains a 1:9 WSS with 100GHz spacing and a 9:1 coupler structure. The WSS input port and all coupler input ports C1…C9 are monitored for LOS, and are equipped with per channel VOAs.
In order to support 80-channel operation with 50GHz spacing, two cards are required (a standard F09MDRT-1/S card and an offset F09MDRT-1/O card). These two cards are operated in parallel using an interleaver to support a total of 16 tunable add/drop channels per each transmission direction.
The F9MDRT-1/x card can be used in a ROADM application (mainly for Metro core networks) or as a non-directional terminal in an ONN-X configuration.
Fig. 30 F09MDRT-1 card structure
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
33
2.2.3.5 F06DR80-1 and F06MR80-1
The F06DR80-1 and F06MR80-1 cards allow SURPASS hiT 7300 to support wavelength selective switching for building a multi-degree 80-channel PXC providing full access to 80 optical channels. The F06DR80-1 and F06MR80-1 cards include an integrated 1:6 (in the F06DR80-1) or 6:1 (in the F06MR80-1) MEMS-WSS module, providing a remotely (via software) reconfigurable optical switching function per individual wavelength.
The input DWDM signal from the line interface (optical pre-amplifier) is switched per wavelength by the MEMS-WSS module on the F06DR80-1 card, either to any of the cross-connect output ports or to one of the two local drop traffic ports, which are already divided into two 40-channel frequency groups of the standard and offset grids, respectively, so that no interleaver is required.
The F06DR80-1 provides a LOS monitor for the input signal is provided for laser safety control at the line interface and each output port is also supervised for over-power detection to ensure laser safety of hazard level 1M.
The output DWDM signal to a line interface (optical booster) is created by the MEMSWSS module on the F06MR80-1 card, which switches per wavelength from any of the cross-connect input signals or from one of the two local add traffic ports, which are already divided into two 40-channel frequency groups of standard and offset grids.
The internal cross-connect traffic ports from the F06DR80-1 and F06MR80-1 cards (of different line directions) can be interconnected to allow a configurable pass-through traffic between arbitrary line directions.
Fig. 31 F06DR80-1 and F06MR80-1 cards structure
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 34
2.2.3.6 F09DR80-1 and F09MR80-1
The F09DR80-1 and F09MR80-1 cards allow SURPASS hiT 7300 to support wavelength selective switching for building a multi-degree 80-channel PXC providing full access to 80 optical channels. The F09DR80-1 and F09MR80-1 cards include an integrated 1:9 (in the F09DR80-1) or 9:1 (in the F09MR80-1) PLC-WSS module, providing a remotely (via software) reconfigurable optical switching function per individual wavelength.
The F09DR80-1 card is used as a demultiplexer in an ONN-X80 (in a PXC architecture with nodal degree of up to 8). It includes a monitor diode at the input port for LOS detection and signaling via LSB and monitor diodes at the 9 outputs ports for overpower detection and signaling via LSBus.
The F09MR80-1 card is used as a multiplexer in an ONN-X80 (in an 8x8 PXC architecture) and in the ONN-R80.
TIP The F09DR80-1 and F09MR90-1 cards can be used as spares of the F06DR80-1 and F06MR80-1 cards, respectively.
The combination of both the F09DR80-1 and F09MR80-1 cards allows a higher extinction ratio and better reach when compared to a case where a combination of WSS and power splitter is used. This measure is of advantage for the narrow channel spacing.
Fig. 32 F09DR80-1 and F09MR80-1 cards structure
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
35
Fig. 33 F09DR80-1 and F09MR80-1 cards structure HW
Fig. 34 HW layout
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 36
2.2.3.7 F09MDR96-1
The F09MDR96-1 is a bidirectional tunable WSS card with colorless ports capable of multiplexing and demultiplexing up to 96 channels. Each card is constituted by two WSS modules for multiplexing and demultiplexing 9 channels on 50 GHz spacing.
Each card, in the demultiplexing WSS module, includes a monitor diode at the input port for LOS detection and signaling to laser safety bus and to Fault-Management. At each output port a monitor diode for overpower detection and signaling to controller and to laser safety bus.
The Multiplexing WSS has in each input port, monitors for Automatic Port Connection Detection (APDC), power level measurement and LOS detection.
Fig. 35 F09MDR96-1 card structure
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
37
2.2.3.8 O09CC-1 Optical Coupler Card
The O09CC-1 is a bidirectional card which implements a Bidirectional Splitter-Combiner for Colorless Add/Drop.
The multiplexer part is equipped with a 9:1 combiner. All inputs includes a monitor diode for LOS detection and signaling to laser safety bus and to Fault-Management. Demultiplexer part is equipped with a 1:9 splitter. Common input includes a monitor
diode for LOS detection and signaling to laser safety bus and to Fault-Management.
Fig. 36 O09CC-1 card structure
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 38
2.2.3.9 F80DCI Drop Splitter and Interleaver Card
The F80DCI cards is used in 80-channel ROADM NE's for demultiplexing of an 80-channel DWDM signal with 50 GHz spacing by de-interleaving into the corresponding 40-channel standard and offset frequency groups of 100 GHz spacing each.
The F80DCI card contains one optical 50GHz/100GHz interleaver filters, one LOS monitor for the received 80-channel line signal, and power level monitors for the outgoing 40-channel signals are used for laser safety control.
Fig. 37 F80DCI-1 card structure
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
39
2.2.3.10 F80MDI Interleaver Card
The F80MDI cards is used in 80-channel Terminal and OADM NE's for multiplexing/demultiplexing of an 80-channel DWDM signal with 50 GHz spacing by interleaving/de-interleaving the corresponding 40-channel standard and offset frequency groups of 100 GHz spacing each. The F80MDI card contains 2 optical 50GHz/100GHz interleaver filters, power level monitors for outgoing 40-channel signals are used for laser safety control. An auxiliary optical input is provided for later access to auxiliary laser light for transient suppression (future release) in combination with a monitor port for the 80-channel output signal.
F80MDI 1 card structure
Fig. 38 F80MDI-1 card structure
Fig. 39 HW layout
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 40
2.2.4 Applications of Wavelength-Selective Switch Cards
2.2.4.1 ONN-R with F40MR-1 - Wavelength-Selective Switch (WSS) Card
The F40MR card includes an integrated Planar Lightwave Circuit based wavelength selective switch (PLC-WSS) with low insertion loss, providing a remotely (via SW) reconfigurable optical switching function per individual wavelength.
The output DWDM signal towards the line interface (booster or booster-less interface) of the PLC-WSS is a DWDM signal resulting from multiplexing 40 optical channels which are individually selectable (via SW control) between the 40 incoming pass-through channels and the 40 local add channels. For each optical channel to be transmitted a VOA function and an optical power monitor diode are available. The input DWDM signal from the line interface (optical pre-amplifier) is optically splitted into pass-through traffic and local drop traffic, where the pass-through direction also provides an optical input power monitor for detection of loss-of-signal and laser safety control. The pass-through traffic ports are connected to the pass-through traffic ports of the F40MR card for the corresponding opposite line direction, thereby achieving East/West Reparability between the respective DWDM line directions.
The F40MR-1 card provides 45 front connectors within 23 duplex LC/PC connectors on the front panel for access to all optical ports, it occupies 3 slots (3x 30mm).
ROADM architecture for 40 channels, ONN-R
• Nodal degree 1..5, in-service upgrade from terminal to ROADM
• Alternatively: F02MR based on WSS technology can be used channel power monitors, and local add filters
• support of patch through on drop side to ROADM node in 2nd ring (ring interconnect)
Fig. 40 F40MR-1 - Wavelength-Selective Switch (WSS) Card
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
41
2.2.4.2 ONN-R2 with F02MR-1 - Wavelength-Selective Switch (WSS) Card
The F02MR is a cost optimized alternative to the F40MR card. It includes an integrated MEMS WSS based wavelength selective switch (MEMS-WSS) with low insertion loss, providing a remotely (via SW) reconfigurable optical switching function per individual wavelength. In the Tx path, the key component of this card is the integrated MEMS based 2:1 wavelength selective switch (MEMS-WSS) module, providing a remotely (via NMS) reconfigurable optical switching function per individual wavelength. The incoming signals of the cross-connect are switched with the WSS module on the common output which is followed by a booster amplifier. One of the inputs of the WSS is connected to the output of a mux filter where the local add channels are inserted.
In the RX path, the incoming signal from the pre-amplifier is launched into a 1x2 splitter with a 40/60 splitting ratio. At the higher output port, a demux filter (F40/S) can be connected for local drop traffic. The other port is the output of the cross-connect. At both inputs of the WSS and the C-COM port of the splitter, LOS monitors are used for supervision. Also a power monitor is present at the splitter drop output.
For internal use
ROADM architecture for 40 channels, ONN-R2
• Nodal degree 1..2, in-service upgrade from terminal to ROADM
• Alternatively: F40MR based on PLC technology can be used with integrated VOAs, channel power monitors, and local add filters
• East-west separation per design
• support of patch through on drop side to ROADM node in 2nd ring (ring interconnect)
Fig. 41 F02MR-1 - Wavelength-Selective Switch (WSS) Card
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 42
2.2.4.3 ONN-X with F08MR card 40-Channel Multi-Degree Wavelength-Selective Switch (MEMS-WSS)
The F08MR card which includes an integrated MEMS based 8:1 wavelength selective switch (MEMS-WSS) module, providing a remotely (via SW) reconfigurable optical switching function per individual wavelength.
The input DWDM signal from a line interface (optical pre-amplifier) is optically splitted into 7 cross-connect outputs and 1 local drop traffic output, where the drop output also provides an optical input power monitor for detection of loss-of-signal and laser safety control. The WSS module collects DWDM traffic from 7 other line ports and 1 local add traffic input and performs arbitrary pass-through switching for any wavelengths from any input of its 8 input ports towards its output port.
The internal cross-connect traffic ports from different F08MR cards (of different line directions) can be optically interconnected to allow for configurable pass-through traffic between arbitrary line directions.
The MEMS-WSS unit supports hitless wavelength switching for any unchanged optical channel interconnections.
For internal use
Photonic Cross Connect (PXC) for 40 channels
Amplifier
Splitter
Channel Filter
West(trunk 1)
East(trunk 2)
WDM trunk8 ports
100GHzWSS
local add
WDM trunk8 port
WDM trunk8 ports
WDM trunk8 ports
local drop
• PXC, supporting nodal degree 8
• one WSS for channels add and one splitter for channel drop per nodal degree
• fully remotely configurable
• east-west separation
• (only two degree shown in figure)
F08MRF08MR
F40/SF40/S
F40/S
Local drop
100GHzWSS
F40/S
Local add
Fig. 42 F08MR-1 - Wavelength-Selective Switch (WSS) Card
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
43
2.2.4.4 ONN-RT - The 8 or 16-Channel Metro Tunable ROADM with Multi-Degree Wavelength-Selective Switch (MEMS-WSS)
The F09MDRT-1/x is a bidirectional tunable WSS card. Each of the drop channels of the WSS is tunable and remotely configurable. I contains a 9x1 WSS with 100GHz spacing and a 9x1 coupler structure. In order to support 80 channel operation with 50GHz spacing, two cards are required with a /S and /O variant of the WSS card.
These two cards are operated in parallel using an interleaver and this combination supports a total of 2x8 channels of tunable add/drop.
For internal use
East(trunk 2)
West(trunk 1)
100GHzWSS
8ch/16ch Metro Tunable ROADM – 40/80 channels
Per ch VOA
100GHzWSS
Per ch VOA
• Each add/drop wavelength is tunable and remotely configurable
• Nodal degree 1..2 incl. in-service upgrade
• 80 channel via interleaver and 2x 8ch add/drop with off set grid card F09MDRT /O
F09MDRT
F09MDRT
Fig. 43 F09MDRT-1 - Wavelength-Selective Switch (WSS) Card used as ONN-RT
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 44
2.2.4.5 ONN-X with F0xDR80 and the F0xMR80 cards (80-Channel Multi-Degree Wavelength-Selective Switch (MEMS-WSS))
The F0xDR80 and the F0xMR80 cards each including an integrated MEMS based 1:6 (6:1) or 1:9 (9:1) wavelength selective switch (MEMS-WSS) module, providing a remotely (via SW) reconfigurable optical switching function per individual wavelength.
The input DWDM signal from a line interface (optical pre-amplifier) is switched per wavelength by the MEMS-WSS unit on the F0xDR80 card, either to any of cross-connect output ports or to one of the two local drop traffic ports, which are already divided into two 40-channel frequency groups of standard grid and offset grid, respectively, so that no further interleaver is needed. A LOS monitor for the input signal is provided for laser safety control at the line interface and each output port is also supervised for overpower detection to ensure laser safety of hazard level 1M.
The output DWDM signal to a line interface (optical booster) is created by the MEMS-WSS unit on the F0xMR80 card, which switches per wavelength from any of the cross-connect input signals or from one of the two local add traffic ports, which are already divided (by the feeding multiplexer cards, not shown in Figure) into two 40-channel frequency groups of standard grid and offset grid.
The internal cross-connect traffic ports from F0xDR80 and F0xMR80 cards (of different line directions) can be optically interconnected to allow for configurable pass-through traffic between arbitrary line directions.
The MEMS-WSS units support hitless wavelength switching for any unchanged optical channel interconnections.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
45
For internal use
50GHzWSS
West(trunk 1)
East(trunk 2)
C
C
F06MR80
50GHzWSS
F40/S F40/O
F80DCI
F40/S F40/O F40V/O
F06MR80
F40V/S
F80DCI
F40V/OF40V/S
Splitter
Channel Filter
Interleaver
Amplifier
• Nodal degree 2, in-service upgrade from terminal to ROADM
• Power monitoring per channel via one MCP card
• East-west separation per design
Remotely configurable ROADM – 80 channels
Local drop Local drop Local add Local add
Local drop Local dropLocal add Local add
Fig. 44 F06MR80-1 - Wavelength-Selective Switch (WSS) Card used as ONN-R80
For internal use
WDM trunk 6 or 8
PXC with double WSS structure for 80 channels incl. local add drop
50GHzWSS
F0xMR80
50GHzWSS
F0xDR80
F0xDR80F0xMR80
50GHzWSS
50GHzWSS
WDM trunk 6 or 8 WDM trunk 6 or 8
WDM trunk 6 or 8
West(Trunk 1)
East(Trunk 2)
• Nodal degree 5 or 8, plus local add/drop
• Drop amplifiers (type LAS) for increased power budget and reach
• (only two directions shown in figure)
Local drop
F40/S F40/O
Local drop Local add
F40/S F40/O
Local add
F40/S F40V/OF40/S F40V/O
Local drop Local dropLocal add Local add
Amplifier
Channel Filter
Fig. 45 F0xMR80-1 and F0xDR80-1 - Wavelength-Selective Switch (WSS) Card
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 46
2.2.4.6 ONN-X96 with F09MDR96-1 cards (MEMS-WSS))
The F09MDR96-1 card include an integrated MEMS based 1:9 (9:1) wavelength selective switch (MEMS-WSS) module, providing a remotely (via SW) reconfigurable optical switching function per individual wavelength.
The input DWDM signal from a line interface (optical pre-amplifier) is switched per wavelength by the MEMS-WSS unit on the F09MDR96-1 card, either to any of cross-connect output ports or to one of the two local drop traffic ports, which are already divided into two 48-channel frequency groups of standard grid and offset grid, respectively, so that no further interleaver is needed. A LOS monitor for the input signal is provided for laser safety control at the line interface and each output port is also supervised for overpower detection to ensure laser safety of hazard level 1M.
The output DWDM signal to a line interface (optical booster) is created by the MEMS-WSS unit on the F09MDR96-1 card, which switches per wavelength from any of the cross-connect input signals or from one of the two local add traffic ports, which are already divided (by the feeding multiplexer cards, not shown in Figure) into two 48-channel frequency groups of standard grid and offset grid.
The internal cross-connect traffic ports from F09MDR96-1 cards (of different line directions) can be optically interconnected to allow for configurable pass-through traffic between arbitrary line directions.
The MEMS-WSS units support hitless wavelength switching for any unchanged optical channel interconnections.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
47
For internal use
• Nodal degree 1 up to 8, in-service upgrade from terminal to PXC
• Power monitoring per channel MCP card
• East-west separation per design
Photonic cross connect PXC – 96 channels
LABBC
LABPC
LABPC
LABBC
Expresschannels
Expresschannels
OTSC
OTSCMCP
MCP
F09MDR96-1
WSS 9x1
WSS 9x1
F09MDR96-1
WSS 9x1
WSS 9x1
F48MDP-1/S F48MDP-1/O
Add/dropchannels
Add/drop
F48MDP-1/S F48MDP-1/O
Add/dropchannels
Add/drop
Fig. 46 F09MDR96-1 - Wavelength-Selective Switch (WSS) Card used as ONN-X96
For internal use
Directionless and colorless PXC – ONN-X96
LABBC
LABPC
LABPC
LABBC
Expresschannels
ExpresschannelsF09MDR96-1
WSS 9x1
WSS 9x1
F09MDR96-1
WSS 9x1
WSS 9x1
WSS 1x9F09MDR96-1
O09CC-1
WSS 9x1
WSS 9x1 F09MDR96
Add/drop channels Add/drop channels
WSS 1x9 WSS 9x1 F09MDR96
Add/drop channels Add/drop channels
WSS 1x9…
… to transponder cards – max. 81 wavelengths …
Fig. 47 F09MDR96-1 - Directionless and colorless PXC for 96 channels
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 48
2.3 Amplification scheme
2.3.1 EDFA amplifiers
The Line Amplifier (LA) cards provide the signal amplification by featuring a gain block with one or two pump lasers, inter-stage access for dispersion compensation, and digital gain control.
SURPASS hiT7300 offers various types of amplifier cards well suited for various network scenarios, depending on the required performance of the span. The amplifier design is multi-stage and modular. This allows for “application optimized” solutions and “cost optimized” choice of amplifiers. The modular amplifier design ensures the lowest possible CAPEX investment for each supported network scenario.
LA cards are divided in three types of amplification (inline, booster and preamplifier):
• Inline amplifiers contain an optical inline amplifier for C band and are used at inline sites for optical amplification of the signal. The output power of the cards can be increased by pump cards and Raman pump cards.
• Booster amplifiers contain an optical booster amplifier for C band and are used at terminal sites for amplifying the outgoing line signal. In one link direction, there is only one booster. The output power of these cards can be increased by pump cards.
• Pre-amplifiers contain an optical preamplifier for C band and are used at terminal sites for amplifying the incoming line signal before it is fed into the demultiplexing stage. In one link direction, there is only one preamplifier. The output power of the cards can be increased by pump cards and Raman pump cards.
Additionally, the various types of amplifiers can be categorized into 3 generic types:
• Line Amplifier Short Span (LASx)
• Line Amplifier Medium Span (LAMx)
• Line Amplifier Long Span (LALx)
• Line Amplifier Very Long Span (LAVx)
• Line Amplifier Broadband for 96 channels (LABx)
TIP All the amplifier cards also have internal bus connection for EOW, user channel access and APSD control functions.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
49
The following table lists all the SURPASS hiT7300 EDFA Amplifier cards:
Card name Usage Types of amplification
LAVBC-1; LAVBCH-1 Very Long; OSC high power
Booster amplifier
(low noise figure)
LAVIC-2 Very Long Inline amplifier (low noise figure)
LALBC-1; LALBCH-1 Long; OSC high power Booster amplifier
LALIC-1 Long spans Inline amplifier
LALPC-1 Long spans Pre-amplifier
LAMIC-1 Medium spans Inline amplifier
LAMPC-1 Medium spans Pre-amplifier
LASBC-1 Short spans Booster amplifier
LIFB-1 Short spans Booster-less line interface card
LIFPB-1 Passive short span Amplifier-less line interface card
LABBC-1 Medium to Very Long spans (96 ch)
Booster amplifier
LABIC-1 Medium to Very Long spans (96 ch)
Inline amplifier
LABPC-1 Medium to Very Long spans (96 ch)
Pre-amplifier
Fig. 48 EDFA amplifiers
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 50
2.3.1.1 Line Amplifier for Short Span (LASBC)
The LASBC amplifier is an EDFA dual-stage amplifier card designed for short span applications without Interstage access. LASBC can be used as a booster amplifier in all ONN node types. The EDFA “Stage 1” is optimized for amplification of a low power signal and therefore for low noise amplification. With a Gain Flattening Filter (GFF) and an automatically controlled Variable Optical Attenuator (VOA) between EDFA stages 1 and 2, the excellent gain flatness is achieved over a wide range of gain settings.
An external monitor interface for connection to an Optical Spectrum Analyzer or the optical channel power monitor card is also available for external signal monitoring functions. The amplifier also has internal signal monitoring functions on the board. The OSC (Optical Supervisory Channel) termination is done locally on the card and control information is digitally forwarded into the main controller.
The EDFA “Stage 2” does the final amplification of the DWDM signal before it re-enters the fiber, allowing for maximum reach.
2.3.1.2 Line Amplifiers for Medium Span (LAMPC, LAMIC)
The LAMPC and LAMIC cards are dual-stage EDFA amplifier cards for medium span applications and provide an additional “Interstage” access port for dispersion compensation. The LAMPC can be used as a preamplifier card in all the ONN node types, and the LAMIC card can be used as an in-line amplifier card in the OLR nodes.
The interstage access points between each EDFA section allow for the addition of inline optical components to enhance the performance of the amplification process as well as the overall network performance. The interstage port can be optionally interconnected with either a Dispersion Compensation Fiber (DCF) or a Fiber Bragg Grating (FBG) card depending on type of fiber choice and dispersion compensation requirement of the network.
The EDFA “Stage 1” together with the Variable Optical Attenuator (VOA) provides moderate optical amplification so that the output signal level is appropriate for interconnection to a dispersion-compensating device interconnected at the interstage access port.
All the attenuation incurred by any interstage optical device is already calculated in the optical link budget and the “Stage 2” EDFA provides optimum amplification for the following span.
All other functions such as OSC extraction and insertion, internal and external signal monitoring and gain flattening filter are also available.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
51
EDFAStage 1
EDFAStage 2
Variable Optical Attenuator ( VOA )
INPUT OUTPUT
Line Amplifier Short Span ( LASBC)
External Monitor
GFF
Int.Mon
OSC filter
Fig. 49 Line Amplifier for Short Span (LASBC)
EDFAStage 1
EDFAStage 2
Interstage access port:
Optional DCF or FBG
Variable Optical Attenuator ( VOA )
INPUT OUTPUT
Line Amplifier Medium Span (LAMPC, LAMIC)
External Monitor
GFF
Int.Mon
OSC filter
OSC filter
Fig. 50 Line Amplifiers for Medium Span (LAMPC, LAMIC)
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 52
2.3.1.3 Line Amplifiers Long and Very Long Span (LALBC, LALBCH, LALIC, LALPC , LAVBC and LAVIC)
The LALBC/LALIC/LALPC amplifier cards provide three-stage EDFA amplification for long span applications. The LALBC can be used as booster amplifier card, and the LALPC can be used as preamplifier card in all ONN node types, whereas the LALIC can be used as in-line amplifier in OLR nodes.
All LALxC cards provide all the features provided by LASBC and LAMxC cards and further provide “Stage 3” amplification with optional access to an external PUMP card for extra amplification in applications with very long spans and/or high number of optical channels.
The LALxC cards can also compensate for higher attenuation at their interstage access port, which is useful for cascading of dispersion compensation cards.
TIP The difference between LALBC and LALBCH is that LALBCH contains a high power OSC laser which provides for a maximum span loss of 50 dB at 1510nm OSC wavelength (corresponding to about 48.5 dB span attenuation of G.652 fiber within C-band).
The LAVBC and LAVIC amplifier cards are similar to the LALxC cards, but generate just a low noise figure.
2.3.1.4 Line Amplifiers for 96 channel system (LABBC, LABIC and LABPC)
The LABBC/LABIC/LABPC amplifier cards provide three-stage EDFA amplification for medium to very long span applications. The LABBC can be used as booster amplifier card, and the LABPC can be used as preamplifier card in all network elements supporting the 96 channel structure, whereas the LABIC can be used as in-line amplifier in OLR nodes.
TIP The LABxC amplifier do not support DCM modules. They where designed for the DCM free transmission and have due to this no interstage access.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
53
Fig. 51 HW layout amplifier
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 54
2.3.1.5 Optical Amplifier Features
Optimum Amplifier Gain Setting and Fast Gain Control: Each hiT7300 amplifier is designed to have the optimum gain flatness over the entire wavelength spectrum for a particular value of total amplifier gain. In order to keep the EDFA's operating at a particular optimum gain, while allowing for a wide range of span losses, an automatically controlled VOA is used between the first and second stage of the amplifier.
A fast control loop (analogue and/or digital) is implemented to keep the gain value constant within the allowed range of overall system transient behavior. This ensures that even abrupt changes in the input signal power, such as those caused by channel losses, will not cause excessive bit errors or degradations in the individual channels.
EDFAStage 1
EDFAStage 3
Interstage Access Port:Optional DCF
or FBG
Stage 3Optional :Pump card
Variable Optical Attenuator ( VOA )
INPUT OUTPUT
Line Amplifier Long Span (LALBC, LALIC, LALPC)
External Monitor
GFF
Int.Mon
OSC filter
OSC filter
EDFAStage 2
Fig. 52 Line Amplifiers Long Span (LALBC, LALIC, LALPC)
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
55
Amplifier Output Power Control: Based on the number of channels equipped in the DWDM system and the required EDFA output power per channel, the total output power of an EDFA can be determined. This total EDFA output power is kept constant via a slow output power control loop, to compensate for degradations or fluctuations in the fiber attenuation. Hence, the typical physical changes in fiber properties (e.g. due to aging) will have no influence on ongoing system performance.
Stage 1 Stage 2 Stage 3
VOA DCM
Digital Gain Control (fast loop)
Digital Gain Control (fast loop)
Input Power
Output Power
Output Power Control (slow loop)
Output Power Control (slow loop)
Fig. 53 Optical Amplifier Features
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 56
2.3.2 Amplifier-less Line Interfaces (LIFB / LIFPB)
LIFB-1 card is a unidirectional booster-less line interface card for the transmit direction of a DWDM line interface; this card can replace a booster amplifier card (LASB) for short span applications.
LIFPB-1 card is a bidirectional amplifier-less line interface card for a DWDM line interface, this card can replace booster and pre-amplifier cards (LASB, LAMP) for passive short span applications.
The LIFB-1/LIFPB-1 cards provide the following functions:
• OSC termination (LIFB: only for Tx direction; LIFPB: for both Tx/Rx directions), in order to support all OSC functions (optical link control, EOW, user channels, etc.) as usual amplifier cards.
• Optical output monitor connector(s) for optical channel power monitoring either by an external optical spectrum analyzer (OSA) or the MCP4xx monitoring card (LIFB: only for Tx direction; LIFPB: for both Tx/Rx directions).
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
57
LIFB
Signal Tap
OSC Filter
Input Monitor
OSC Tx
MonSoSignal Tap
IN
OUT
LIFPB-1
Signal TapOSC Filter
Input Monitor OSC Tx
MonSo
Signal Tap
B-IN B-OUT
Signal TapOSC Filter
Input Monitor
OSC Rx
MonSo
Signal Tap
P-INP-OUT
Fig. 54 Amplifier-less Line Interface (LIFB and LIFPB)
Fig. 55 HW layout
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 58
2.3.3 Amplifier Pump Cards
To account for the variable optical conditions in backbone networks, such as different span lengths, fiber types and fiber properties, SURPASS hiT7300 has developed an external amplifier pump implementation. By equipping the external pump card PL-1 in combination with the LALx amplifier cards, a higher output power of these amplifiers can be achieved. By equipping the Raman pump card PRC-1 in combination (counter-directional) with the LALPC-1 pre-amplifier card or LALIC-1 in-line amplifier card, a higher gain can be achieved for the respective span.
2.3.3.1 External PUMP Card (PL-1)
The external pump card (PL-1) is used to increase the output power of the preamplifier, booster amplifier and inline amplifiers on the various amplifier cards. The PL-1 is an active card, which means it is equipped with its own card controller. It also contains an on-board EEPROM to store card inventory data that can be requested by the network management system.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
59
EDFAStage 1
EDFAStage 3
Interstage Access Port for DCM
Stage 3Optional :
Variable Optical Attenuator ( VOA )
INPUT OUTPUT
Line Amplifier Long Span LALBC
External Monitor
GFF
Int.Mon
OSC filter
OSC filter
EDFAStage 2
PL-1
Polarization Beam
Combiner.
Laserdiodes
InternalMonitor
Fig. 56 External PUMP Card
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 60
2.3.4 Raman amplification
To extend the distances between NE's (high loss spans) SURPASS hiT7300 optionally employs Raman amplification.
The basis of Raman amplification is the energy scattering effect called Stimulated Raman Scattering (SRS), a non-linear effect inherent to the fiber itself. SRS involves a transfer of power from an optical pump signal at a higher frequency (lower wavelength) to one at a lower frequency (higher wavelength), due to inelastic collisions in the fiber medium. If on optical pump wavelength is launched backwards into the end of a transmission fiber it propagates upstream in the opposite direction of the optical traffic wavelength, this is called counterdirectional pumping. The pump wavelength induces the SRS effect resulting in amplification of the optical traffic wavelength. With a sufficient amount of pump wavelength power the optical traffic wavelength slowly starts to deviate from the usual linear decrease, reaches a minimum level and finally increases when approaching the fiber end The distributed Raman amplification process results in an improvement of the OSNR budget by several dB thereby allowing networks with very long transmission span in combination with optical booster and preamplifiers.
2.3.4.1 Raman Pump Card (PRC-x)
The following picture shows the simplified internal architecture of the Raman pump card (PRC-x). The pump signals from the Laser diodes are first multiplexed from two different wavelengths, and the multiplexed pump light is counterdirectionally coupled into the fiber carrying the received traffic signal. By appropriate power settings for the two pump wavelengths, a flat gain spectrum can be achieved for different fiber types. The pump laser power is controlled via external monitor diodes and the output power is set by software. All pump lasers are also temperature controlled to maintain their stability. Two optical monitor ports are provided, one monitors the Raman output power and the other one monitors the line power.
The Raman PUMP card is utilized together with the LALPC or LALIC amplifier card to increase the possible length of a span.
TIP The card PRC-1 is designed for the 40 and 80 channel system. The card PRC-2 is designed for the 96 channel system and has a broader channel spectrum which is amplified.
TIP For Automatic Power Shut Down (APSD) an on board detection of the OSC carrier frequency is designed. The OSC signal is scrambled to have enough carrier signal power to provide APSD function.
Due to the laser pumps and the complexity of the card, the PRC-x occupies two 30 mm slots of the shelf.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
61
2
0 10 20 30 40 50 60 70 80-18
-16
-14
-12
-10
-8
-6
-4
-2
0
Route Length in km
Po
wer
in d
Bm
Signal
RPump EDFA
PumpLight
Fig. 57 Raman amplification
EDFAStage 1
Variable Optical Attenuator ( VOA )
INPUT
Line PreAmplifier Long Span LALPC
Int.Mon
OSC filter
OS
CM
on
ito
rL
og
ic U
nit
Raman Pump Amplifier Card
Lin
eM
on
ito
rR
Pu
mp
Mo
nit
or
Lin
eIN
PU
T
Lin
eO
utp
ut
Int.
AP
SD
WD
M(2
ch)
Co
ntr
oll
er
Pu
mp
ing
d
irec
tio
n
Fig. 58 Raman Pump Card (PRC-1)
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 62
2.3.4.2 EDFA & Raman hybrid amplifier cards (LRBIC-1 / LRBPC-1)
To simplify network management, the Raman pump card (PRC-2) and either the line amplifier card (LABIC-1) or the pre-amplifier card (LABPC-1) can be logically combined into a single card cluster, which offers the following:
• Combined LRBxC-1 (LABxC and PRC-2 card) supporting all features from LABxC-1 and PRC-2
• Implementation of Raman padding or Raman pump power control by LABxC
• Cards have to be placed in adjacent slots (future plans to have LABxC controlled as single card by the management system)
TIP For LRBIC-1 and LRBPC-1 cards technical specifications see the respective LABIC-1 and LABPC-1 cards and PRC-2 technical specifications.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
63
• Combined LRBxC-1 (LABxC and PRC-2 card) supporting all features from LABxC-1 and PRC-2
• Implementation of Raman padding or Raman pump power control by LABxC• Cards have to be placed in adjacent slots (future plans to have LABxC controlled as single
card by the management system)
LA
BI C
-1
PR
C-2
LA
BP
C-1
PR
C-2
CF
SU
-1
CC
SP
-1M
CP
4
Super RamanPump
PRC-2
Preamplifier
Booster
PRC-2
LABI C-1
LABP C-1
Super Ramanpump
To simplify network management, the Raman pump card (PRC-2) and either the line amplifier card (LABIC-1) or the pre-amplifier card (LABPC-1) can be logically combined into a single card cluster , which offers the following:
LRBIC LRBPC
Fig. 59 Hybrid Amplifier Card (LRBxC-1)
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 64
2.4 Dispersion compensation scheme The chromatic dispersion has the effect of ‘spreading’ the signal spectrum so much that the inter-symbol interference no longer allows an accurate determination of a single ‘one’ bit or a single ‘zero’ bit. Dispersion compensation is used to counteract the chromatic dispersion which a signal undergoes as it travels through a section of optical fiber. Depending on the bit rate a system can tolerate a certain degree of dispersion; the rest has to be compensated for to avoid bit errors. This can be done in different ways, using pre- and post-compensation, so a kind of saw tooth profile results. The important fact is that the total allowable dispersion at the receive side is not exceeded.
2.4.1 Dispersion Compensation Cards
The DCM's (Dispersion Compensation modules) are utilizing either Fiber Bragg Gratings (FBG) or Dispersion Compensating Fiber (DCF). DCF is a spool of fiber with the opposite dispersion characteristics of the fiber used for signal transmission, hence ‘compressing’ the signal for better optical performance. FBG's are based on chirped fiber grating technology and offer smaller footprint, very low insertion loss, and lower nonlinear effects compared to DCF.
In hiT 7300 the DCM modules are in most cases integrated on DCM cards which are physically equipped in the hiT 7300 shelf as all other equipment and are managed by the NE controller. For special applications, where FBG-based DCMs are not available or cannot be used (e.g. for compensation of critical transmission lines with 40G channels or for 80-channel transmission lines), or for dispersion compensation of special fiber types, DCF-based external DCMs can be used which are mounted within a separate DCM shelf within the rack.
The front panel of a DCM cards contains two optical connectors, one input port of the DWDM signal before dispersion compensation and one for output port of the DWDM signal after dispersion compensation. The DCM input and output ports are connected to the interstage access port of an optical amplifier.
There are various DCM card types available for providing dispersion compensation of different lengths and types of transmission fibers. A certain DCM module on a DCM card is denoted by the card name.
TIP The strategy for choosing DCM's is highly system dependent and is influenced by the optical performance limiting effect. The implementation of the DCM strategy and the correct calculation of the required residual dispersion is a feature of the network design tool SURPASS TransNet. Both DCM types can be combined to achieve the optimum network performance and the lowest system cost.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
65
0
Dis
per
sio
n
DistanceDCFDCF
DCF
DCFDmax
Fig. 60 Dispersion compensation scheme
DCF
Termination
Red
Blue
FBG
InOUT
Optical Circulator
FBG
OUT
In
Fiber Bragg Gratings
Dispersion Compensation Fiber
Dispersion Compensation Cards (DCF and FBG)
Fig. 61 Dispersion Compensation Cards
EDFAStage 1
EDFAStage 3
Interstage Access Port for DCM
Variable Optical Attenuator ( VOA )
INPUT OUTPUT
Line Amplifier Long Span LALBC
External Monitor
GFF
OSC filter
OSC filter
EDFAStage 2
DCF
OUTIn
Fig. 62 Example of DCM usage
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 66
Fig. 63 HW layout
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
67
2.5 Transponder, Muxponder, and Regenerator Functions
Each transponder or muxponder (=multiplexing transponder) converts one or several of its client signals of grey or CWDM wavelength into a colored line signal with specific DWDM wavelength according to the hiT7300 wavelength plan. Each transponder line interface provides an excellent span performance for regional as well as long haul networks by using optical DWDM modules with high dispersion tolerance in combination with FEC or SUPER-FEC ((SUPER-) Forward Error Correction). Each transponder/muxponder card can also support optical channel protection (OChP) for its line interface(s), which allows carrier-class survivability for its client services.
2.5.1 hiT7300 Transponder, Muxponder, and Regenerator Cards
The SURPASS hiT7300 transponder, muxponder, and regenerator cards offer a broad range of fully transparent data transmission services for various user applications. They are designed for interfacing to optical channels of data rate levels 2.5 Gb/s and 10 Gb/s within an Optical Transport Network (OTN) and support all the fault supervision and performance monitoring functions according ITU-T G.709.
TIP Note that SURPASS hiT7300 transponder cards can be used as integral part of SURPASS hiT7300 NE's, or alternatively for interworking with SURPASS hiT7500 or any other 3rd party DWDM equipment.
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 68
The following transponder card types are supported:
Card name
Typical Line bit
rate (Gbit/s)
Transport network
Error Correction
Type of hot-
pluggable modules
I04T2G5 2.50 Regio FEC SFP & DWDM-SFP
I01T10G 10.00 LHD/LH/Regio/Regio80/Metro FEC / S-FEC XFP
I08T10G 10.00 LHD/LH/Regio/Regio80/Metro FEC / S-FEC SFP
I04TQ10G 10.00 LHD/LH/Regio/Regio80/Metro FEC / S-FEC XFP
I05AD10G 10.00 Regio FEC SFP & DWDM-XFP
I22CE10G 10.00 LHD/LH/Regio/Regio80/Metro FEC / S-FEC SFP, SFP+, XFP
I01T40G 40.00 S-FEC ---
I01R40G 40.00 S-FEC ---
I04T40G 40.00 S-FEC XFP
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
69
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fig. 64 Multipurpose Modular Transponder, Muxponder, and Regenerator Cards
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 70
The table on the next page gives an overview of the different transponder cards with their possible client interfaces.
For the 10G transponder/muxponder cards, the following optical variants of the 10G colored line interfaces are available on the respective card variant as denoted by the following suffixes:
• Metro: optimized for passive metro networks with 40 channels (up to 80 km reach) using fixed wavelength;
• Regio: optimized for regional networks (up to 600 km reach w/ optical amplifiers) with fixed wavelength;
• Regio80: optimized for regional networks with 40/80 channels (up to 600 km reach w/ optical amplifiers) using fixed wavelength;
• LH: optimized for long haul networks (up to 1600 km reach w/ optical amplifiers) with tunable wavelength;
• LHD: optimized for ultra long haul networks with 40/80 channels (up to 2000 km reach w/ optical amplifiers) using tunable wavelength, and with increased chromatic and polarization mode dispersion tolerance by MLSE (Maximum Likelihood Sequence Estimation) signal processing;
• LHS: optimized for long haul networks (up to 1600 km reach w/ optical amplifiers) via sea cable system with tunable wavelength;
• LHDS: optimized for ultra long haul networks with 40/80 channels (up to 2000 km reach w/ optical amplifiers) via sea cable system using tunable wavelength, and with increased chromatic and polarization mode dispersion tolerance by MLSE (Maximum Likelihood Sequence Estimation) signal processing;
• DPS: Modulation is DPSK: Differential Phase Shift Keying used by 40Gbit/s cards
• CQP: Modulation is CP-QPSK: Coherent Polarization Differential Quad Phase Shift Keying used by 40 Gbit/s cards for DCM free transmission.
• CQPS: like CQP but for sea cable application
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
71
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For internal use
X
FC
-8G
X
FC
-10G
X
any-
rate 100M
-3.4G
X
X
ST
M-1
XXXI04TQ10G
XXI22CE10G
XXXI04T40G-1 (/CQP)
XXI01T40G-1 (/CQP)
XXXXI05AD10G
XXXI01T10G
XXXI08T10G
XXXXXI04T2G5
OT
U-3
OT
U-2
OT
U-1
FC
-4G
FC
-2G
FC
-1G
10 GE
1 GE
ST
M-256
ST
M-64
ST
M-16
ST
M-4
Overview of available Client Interfaces
• SAN services certification: IBM System Storage ProvenTM
Fig. 65 Transponder cards with possible line and client interfaces
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 72
2.5.1.1 I04T2G5-1 card
The 2.5G transponder/muxponder functionality is realized by the I04T2G5-1 card. The card provides the following traffic interfaces:
• 2 pluggable (SFP modules) DWDM line ports;
• 4 pluggable (SFP modules) client ports for the following client interface types: Up to 2x STM-16/OC-48, or up to 4x GE (1000Base-X/T), or up to 4x FC 1G, or up to 2x FC 2G, or up to 2x OTU-1 (w/o FEC).
All traffic ports are realized hot pluggable SFP modules which can be equipped depending on the specific traffic demands for this card, thus providing lowest CAPEX by a single card type for many different applications. For optical client ports, both uncolored and CWDM interfaces are supported.
The electrical and optical Gigabit Ethernet (GbE) SFP interfaces available for the client ports of the I04T2G5-1 card.
The card can be used as transponder/muxponder or as 3R-regenerator card, depending on its configuration.
In case the I04T2G5-1 operates as a transponder/muxponder card, the card offers access for 1 or 2 optical channels with OTU-1 standard data rate (2.67 Gb/s) and FEC acc. ITU-T G.709 at its line interfaces. The required wavelength, which has been determined by the TransNet planning tool, is realized by plugging the correct DWDM SFP module, which is verified by the NE’s controller function.
In case the I04T2G5-1 operates as a 3R-regenerator card, only the two line interface modules are equipped for bidirectional regeneration of an OTU-1 optical channel.
The 2 OTU-1 line interfaces can also be configured for optical channel protection.
The I04T2G5-1 transponder/muxponders implements standard compliant mapping schemes of all client signals types into an OTU-1 optical channel acc. ITU-T G.806 and G.709.
In case of Gigabit Ethernet (GE) or 1 Gigabit FiberChannel (FC-1G) client signals, 2 client signals are mapped into the OPU1 payload of an OTU-1 optical channel via GFP-T generic framing procedure and GFP-T frame multiplexing acc. ITU-T G.7041. This provides a fully transparent transmission of GE services at wire speed over the optical transport network and at the same time achieves efficient bandwidth utilization of the OTU1 optical channel. Mapping via GFP-T avoids any intermediate mapping into SDH/SONET layers and thus simplifies management of GE services. Fault supervision and performance monitoring are possible at OCh and Ethernet/FiberChannel layers for monitoring GE/FibreChannel traffic in both ingress and egress directions.
In case of an STM-16/OC-48 SDH/SONET client signal, one such client signal is mapped into an OPU1 payload of an OTU-1 optical channel acc. ITU-T G.709.
In case of an OTU-1 client signal (IrDI), the ODU1 optical data unit is transparently passed between client and line interface for providing a transparent optical channel including payload and ODU1 overhead.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
73
For internal use
I04T2G5 universal 2.5G Mux/Transponder Card
Best-in-class flexibility: 4 different functionalities in one cardTransponder, Muxponder, Regenerator, Protection
muxponder 2 x FC-1G/GE/STM-1/OC3 w/ line IF protection
transponder 1 x STM16/OC48/FC-2G with line IF protection OTU-1 regenerator
muxponder 2 x(2 x FC 1G/GE/STM-1/OC3)
transponder 2 xSTM-16/OC48/FC-2G
Framing and mapping
Framing and mapping DWDMSFP
DWDMSFP
3RRegeneration
Optical ChannelProtection
I04T2G54 client interfaces
STM-1/OC-3 or
OTU-1 or
STM-16/OC-48 or
GE or
FC-1G or
FC-2G
DWDMSFP
DWDMSFP
DWDMSFP
DWDMSFP
2 line interfaces
OTU-1
OTU-1
Fig. 66 2.5G Transponder/Muxponder/Regenerator Card I04T2G5
For internal use
I04T2G5 Universal 2.5G Mux/Transponder CardMapping of client signals
GFP-T
OChrOTU1OPU1
OChrOTU1OPU1
OTU1
OTU1
ODU1
ODU1
GFP-T
GFP-T
GFP-T
GFPMX/DX
OChr
OChr
asyn.
asyn.
asyn.
OTU-1(w/o FEC)
2.6660514 Gb/s
2.6660514 Gb/s
2.6660514 Gb/s
2.6660514 Gb/s
Line IFClient IF
GE, FC-1G, STM-11.25 Gb/s, 1.0625 Gb/s,
155 Mb/s
GE, FC-1G, STM-11.25 Gb/s, 1.0625 Gb/s,
155 Mb/s
FC-2G2.125 Gb/s
STM16 / OC482.488320 Gb/s
OTU-12.6660514 Gb/s
(a)
(b)
(c)
(d)
• (a) 2xGE, or 2xFC-1G, or 2xSTM1, or any mixture mapped into one OTU1
• (d) client side GCC0 support in-line management of connected remote NT
• direct mapping into OTU („Ethernet over DWDM“) without intermediate SDH/SONET mapping simplifies management
• Line interface with FEC, client interface w/o FEC
• support of jumbo frames of any size
Fig. 67 Example of mapping Schemes of Client Signals to OTU-1 Optical Channel
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 74
2.5.1.2 I01T10G-1 card
The 10G transponder functionality is realized by the I01T10G/LHD/LH/Regio/ Regio80/Metro cards. Each I01T10G-1 card generates and terminates an optical channel of a wavelength appropriate for DWDM transmission. The exact wavelength is controlled via a tunable transmit laser, (only available in the I01T10G-1 LH(S) and I01T10G-1 LHD card). The S-FEC feature allows longer span distances.
The I01T10G-1 LH card is equipped with a Mach Zehnder Modulator (MZM), temperature-controlled and wavelength tunable laser, with wavelength accuracy suitable for 50 GHz and 100 GHz DWDM channel spacing.
The I01T10G-1 LHD card can handle a higher dispersion and a higher PMD load, by using a Maximum Likelihood Sequence Estimator (MSLE).
The optical 10 Gbit/s client interfaces of the I01T10G-1 Regio/LH(S)/LHD card are equipped with one hot-pluggable 10 Gigabit Small Form Factor Pluggable (XFP) module mounted on the front panel of the card. The XFP module, like the SFP, performs the optical/ electrical conversion in both signal directions.
The card can also be used as a 3R-regenerator by back-to-back configuration of two I01T10G via the OTU-2 clients.
The I01T10G-1 transponder implements a standard compliant mapping scheme for STM64/OC192 signals into an OTU-2V optical channel acc. acc. ITU-T G.806 and G.709.
Since a standard 10 Gigabit Ethernet (10GE) LAN signal does not fit into the transport capacity of a standard OPU2 payload, the OPU2 transport capacity is increased using also OPU2 stuffing bytes for payload mapping and slightly increasing the OPU2/OTU2 data rate; by this means the 10GE LAN signal can be transparently transmitted at wire speed over the optical transport network. Fault supervision and performance monitoring are possible at OCh and Ethernet layers for monitoring 10GE traffic in both ingress and egress directions.
The SUPER-FEC scheme in combination with dispersion tolerant optical receiver provides an excellent dispersion tolerance for regional and long haul applications.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
75
For internal use
I01T10G OTU2 Transponder Card
10 Gb/s Transponder with full OTU-2 support
Super-FEC on line side with 8 dB coding gain
Multiple services supported service assignment for client ports– STM-64 / OC-192
– Fully transparent 10 Gigabit Ethernet
– OTU-2
One board type can be equipped for Long Haul (full C Band tunable laser), Regio and Metro (fixed laser) applications
CD-tolerant version (for special fiber types) with +- 1500ps/nm @ 2dB penalty
Client interfaces
1 x OTU-2 or
1 x STM-64/OC-192 or
1 x 10 GE LAN PHY or
1 x 10 GE WAN PHY
Line interface
1 x OTU-2(V)XFP
Line MSA
(LH and Regio)
OTU-2 Framerand Mapper
I01T10G
Fig. 68 10G Transponder Card I01T10G
For internal use
I01T10G OTU2 Transponder CardMapping of client signals
• Standard FEC or Super FEC configurable for the Line IF
• (b) (e) OPU1e mapping mode acc. G.Sup43, utilizing OPU2 stuffing bytes and increased OTU2 data rate
• (c) (f) OPU2e mapping mode, not utilizing OPU2 stuffing bytes but increased OTU2 data rate
• (d) (e) (f) Client side Std. FEC support direct client side interconnect to WDM system
• (d) (e) (f) client side GCC0 support in-line management of connected remote NT
• support of jumbo frames of any size
OTU2(V)Standard FEC(SUPER-FEC)
ODU2 OChnOTU2Std. FEC
10.709225 Gb/s
(11.00320 Gb/s)
OTU2
10.7092253 Gb/s
OTU2(V)Standard FEC(SUPER-FEC)
ODU2 OChnOTU2VStd. FEC
11.049107 Gb/s
(11.352416 Gb/s)
OTU2V11.049107 Gb/s
10GE LAN w/OPU1e mapping
OTU2(V)Standard FEC(SUPER-FEC)
ODU2 OChnOTU2VStd. FEC
11.095728 Gb/s
(11.400316 Gb/s,
only on LHD)
OTU2V11.0957278 Gb/s
10GE LAN PHY w/ OPU2e mapping
OTU2(V)Standard FEC(SUPER-FEC)
ODU2 OChrOPU2 10.709225 Gb/s(11.00320 Gb/s)
STM64 / OC192 /10GbE WAN
9.953280 Gb/s
asyn.
OTU2(V)Standard FEC(SUPER-FEC)
ODU2 OChnOPU2OPU1e
mapping
11.049107 Gb/s,(11.352416 Gb/s)
10GbE LAN
10.3125 Gb/s
syn.
Line IFClient IF
OTU2(V)Standard FEC(SUPER-FEC)
ODU2 OChnOTU2
OPU2e mapping
11.095728 Gb/s(11.400316 Gb/s,
only on LHD)
10GbE LAN
10.3125 Gb/s
syn.
Fig. 69 Mapping of 10G Transponder Card I01T10G
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 76
2.5.1.3 I08T10G-1 Card
The 10G muxponder functionality is realized by the I08T10G/ LHD/LH/Regio/Regio80/Metro cards.
The card provides the following traffic interfaces:
• 1 DWDM line port with tunable wavelength long haul interface for I08T10G/LH and I08T10G/LHD, where LHD refers to a specific card variant with high dispersion tolerance and S stands for see cable application, or fixed wavelength regional interface for I08T10G/Regio card type;
• 8 pluggable (SFP modules) client port for the following client interface types:
4x STM-16/OC-48, or
8x GE (1000Base-X/T), or
4x OTU-1 (w/o FEC).
TIP Also mixed client interfaces are possible, different client interfaces can be chosen per individual ODU1 data unit within the aggregate ODU2 data.
The client traffic ports are realized as hot pluggable SFP module which can be equipped depending on the specific traffic demands for this card, thus providing lowest CAPEX by a single card type for many different applications. For optical client ports, both uncolored and CWDM interfaces are supported.
The SUPER-FEC scheme in combination with dispersion tolerant optical receiver provides an excellent dispersion tolerance for regional and long haul applications.
The I08T10G-1 transponder implements a standard compliant mapping scheme of all client signals into an OTU-2V optical channel acc. acc. ITU-T G.806 and G.709.
In case of Gigabit Ethernet (GE) client signals, 2 client signals are mapped into the OPU1 payload of an ODU1 data unit via GFP-T generic framing procedure and GFP-T frame multiplexing acc. ITU-T G.7041. This provides a fully transparent transmission of GE services at wire speed over the optical transport network and at the same time achieves efficient bandwidth utilization of the OTU1 optical channel. Mapping via GFP-T avoids any intermediate mapping into SDH/SONET layers and thus simplifies management of GE services. Fault supervision and performance monitoring are possible at OCh, STM16/OC48 and Ethernet layers for monitoring client traffic in both ingress and egress directions.
In case of an STM-16/OC-48 SDH/SONET client signal, one such client signal is mapped into an OPU1 payload of an ODU1 data unit acc. ITU-T G.709.
In case of an OTU-1 client signal (IrDI), the ODU1 optical data unit is transparently passed between client and aggregate line interface for providing a transparent optical channel including payload and ODU1 overhead.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
77
For internal use
I08T10G Muxponder card with 10G Line
• 10G muxponder with full ODU-2 support
• 8 SFP grey/C/DWDM clients:
• 4x STM-16/OC-48, or
• 8x GE (1000Base-X/T), or
• 4x OTU-1 (w/o FEC)
• Super-FEC on line side with 8 dB coding gain
• One board type can be equipped for Long Haul (full C Band tunable laser), Regio and Metro (fixed laser) applications
• CD-tolerant version (for special fiber types) with +- 1500ps/nm @ 2dB penalty
Client interfaces
4 x OTU-1or
4 x STM-16/OC-48 or
8 x GE
Line interfaces
1 x OTU-2
(DWDM) SFP
(DWDM) SFP
(DWDM) SFP
(DWDM) SFP
(DWDM) SFP
(DWDM) SFP
(DWDM) SFP
(DWDM) SFP
I08T10G
OTU-2 Framerand Mapper
Line MSA
(fixed or tunable)
Fig. 70 10G Muxponder Card I08T10G
For internal use
I08T10G Muxponder card with 10G LineMapping of client signals
ODU1OPU1 ODTU12STM16CBR
10.709225 Gb/sw/ Std. FEC
11.00320 Gb/sw/ Super FEC
STM-16/OC-482.488320 Gb/s
asyn.
Line IF
Client IF
asyn.
ODU2OPU2 OTU2VODTUG2 OChr
K x
ODU1OTU1(w/o FEC)
ODTU12asyn. L x
ODU1OPU1 ODTU12asyn. M x
GFP-T
GFPMX/DX
GFP-T
OTU12.6660514 Gb/s
GbE1.25 Gb/s
GbE1.25 Gb/s
asyn.
K+L+M ≤ 4
• Standard FEC or Super FEC configurable for the Line IF
• (b) OTU1 framed client format fully compatible with I04T2G5 OTU1 signal (direct interconnect supported)
• (b) client side GCC0 support in-line management of connected remote NT
• (c) GFP-T framing for wire speed transmission of GE clients
• (c) GE clients are directly mapped into OTU („Ethernet over DWDM“) without intermediate SDH/SONET mapping to simplify management
Fig. 71 Mapping of 10G Muxponder Card I08T10G
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 78
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
79
For internal use
Transponder Cards
Fig. 72 Transponder HW layout
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 80
2.5.1.4 I05AD10G-1 Card
With the release R4.2x, SURPASS hiT 7300 supports a new type of multiplexing transponder card which allows an easy and efficient implementation of multi-service aggregation and distribution networks for various lower rate data services, which is required in typical backhaul applications within mobile networks and DSL provider networks. The I05AD10G card performs time division multiplexing of different client data services in combination with add/drop functionality into colored 10G optical channel signals for direct transmission over metro and regional DWDM networks. This 1-slot card has a total capacity of 9xGE or 2x 4G FC per OTU-2 channel. See following Figure for a simplified block diagram of this card. The card is also referred to as ‘ADM on a blade’.
Line Interfaces: 2 pluggable (XFP modules) DWDM line ports for interface type:
• 2x OTU-2 (w/ standard FEC);
available as Regio or Metro type depending on optical reach requirements. For special applications, also grey (non-colored) C/DWDM XFPs can be equipped. At the network (line) side the card offers access for 1 or 2 optical DWDM channels with OTU-2 standard data rate (10.7 Gb/s) and FEC acc. ITU-T G.709. The required wavelength is realized by plugging the correct DWDM XFP module, which is verified by the NE’s controller function. The 2 OTU-2 line interfaces can also be configured for optical channel protection (OChP, see Chapter 4) with respect to the individual multiplexed client services. In R4.30, the O02CSP-1 can be used for line side protection.
Client Interfaces: 5 pluggable (SFP modules) client ports for the following client interface types individually:
• up to 5x GE (1000Base-X/-T), or
• up to 4x FC/FICON 4G
• STM-1/OC3, STM4/OC12 or STM16/OC48 (new in 4.30)
• Anyrate muxponder / ADM (100 Mbit/s – 3.4 Gbit/s, free mix with other clients), new in 4.30
Also mixed client interface (e.g. 1x FC-4G +4x GE; 2x FC4G + 3x GE, 3x FC-4G + 2x GE) are possible.
All traffic ports are realized as hot pluggable SFP/XFP modules which can be equipped depending on the specific traffic demands for this card, thus providing lowest CAPEX by a single card type for many different applications.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
81
For internal use
I05AD10G Multi-service Add-drop Multiplexer (ADM)
• Add/Drop Multiplexer (ADM) with dual Muxponder application• grey/C/DWDM XFP based line ports• grey/C/DWDM SFP based client ports for the following client interface types
• up to 5x GE (1000Base-X/-T), STM-1/OC-3*, STM-4/OC-12*, • up to 4x FC-4G / FICON 4G, STM-16/OC-48*• mixed client interfaces • Anyrate clients (100 Mbit/s – 3.4 Gbit/s, free mix with other clients)*
• Direct optical connection of I05AD10G to I01T10G, I04TQ10G and I04T40G
• 1 slot card, Total capacity per OTU-2: 9xGE or 2x 4G FC
• GFP Channel Protection via second line port
• Drop & Continue / Broadcast Function * Rel.4.3
DWDM XFP
DWDM XFP
(DWDM) SFP
(DWDM) SFP
(DWDM) SFP
(DWDM) SFP
Client interfaces: GE,
STM-1/OC-3*, STM-4/OC-12*,
FC-4G, STM-16/OC-48*,
anyrate*(DWDM) SFP
GFP-T MapperAdd/Drop Switch
2 line interfaces
OTU-2
OTU-2
Fig. 73 10G Multiservice Add-drop Multiplexer Card I05AD10G
I05AD10G Multi-service Add-drop Multiplexer (ADM)
• Standard FEC on the OTU2 line IF• GFP-T framing for wire speed transmission of GE clients (L2 functionality handled
by I22CE10G)• GE clients are directly mapped into OTU („Ethernet over DWDM“) without
intermediate SDH/SONET mapping to simplify management
10.709225 Gb/sw/ Std. FEC
Line IF
ODU2OPU2 OTU2
GFP-T
GFPMX/DX
GFP-T
GbE1.25 Gb/s
FC-4G/FICON-4G4.25 Gb/s
asyn.OChr
Client IF(a)
Fig. 74 Mapping of 10G Multiservice Add-drop card I05AD10G
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 82
2.5.1.5 I04TQ10G-1 Card
The I04TQ10G-1 offers in a high degree of flexibility in 10G planning by supporting various application scenarios. The module can be operated as a quad transponder with 4 independent transponders and many different clients, the following configurations are possible:
• 4x independent transponders with any mix of clients
• 2x transponders with channel protection
General properties:
• Up to 8 interfaces total, 4 line and 4 client interfaces, operated with 6 XFPs and 2 SFP+
• Up to 2 client XFPs configurable for line side, SFP+ for client only
• Pluggable modules supported (XFP for line, SFP+ for client)
• 1 slot card width, either in standard or flatpack shelf
• Interface can be sub-equipped
Line side functionality:
Reach up to 1000km can be achieved with pluggable XFPs for Regio (fixed or tuneable wavelengths) and ULH (future). 40 or 80 channel capacity can be achieved. The OTU2V interface with 10% overhead for SFEC is available or the OTU2 interface with standard FEC. Also, support of GCC0 for management purposes.
Client side functionality:
• 10 GE LAN PHY – GFP-F mapping
• 10 GE LAN PHY – Semi-transparent GFP-F (AMCC) mapping
• STM-64/OC-192/10GE WAN PHY
• OTU2 with standard FEC, GCC0, TCM
• FC 8G (8.5GBit/s), for SFP+ only
• FC 10G (10.51875 GBit/s)
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
83
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For internal use
I04TQ10G: Quadruple 10G transponder
• Line side with fixed or tunable WDM XFP (40ch / 80ch option)• Approximately 1000 km reach• Power consumption of < 20 Watt per 10G service• 80 wavelength terminal in 2 shelves• Double regenerator functionality (client XFPs as line XFPs for this mode)• Prepared for internal channel protection (>4.30)
DWDM XFP
DWDM XFP
SFP+
XFP
XFP4 client interfaces
- STM-64, OC-192- 10 GE WAN PHY- 10 GE LAN PHY- OTU2- FC 8G, 10G
SFP+
GFP-T Mapper
4 line interfaces
OTU-2
OTU-2
1-slot card
DWDM XFP
DWDM XFP
OTU-2
OTU-2
Fig. 75 10G Muxponder Card I04TQ10G
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 84
2.5.1.6 I22CE10G-1 Card
The I22CE10G provides a very compact carrier Ethernet switch device, fully integrated within the hiT7300 DWDM platform for Packet Optical Transport. Starting from R 4.30, this I22CE10G traffic card is used for Carrier Ethernet Switch types and provides L2 functions, services and interfaces. Extended switching capacity can be achieved by stacking the card.
General benefits:
• The use in hiT7300 enables integrated CE over WDM
• Saving floor space, no extra rack and equipment is required
• Handling of DWDM and carrier Ethernet switch functionality with one single network management system for simplified operation and trouble shooting
This interface card offers 22 Carrier Ethernet (CE) ports. Four of the 10 GbE ports can be configured as DWDM ports (OTU2) with 10G transmission. The Ethernet switching capacity is 76G (California count 152G).It offers enhanced L2 processing for 1GE and 10GbE client services. Note that in hiT7300 the usage of carrier Ethernet transport (CET) is also possible with the existing transponders and muxponder cards but only the I22CE10G supports the statistical multiplex gain through switching of multiple Ethernet ports to and from OTN interfaces. The T-level slide sets contain more examples on the various applications for the L2 card, including switch stacking, service aggregation.
Line interfaces:
• 4x hybrid (grey/tunable) DWDM XFP based line ports
• 10GE over OTU-2 with Standard FEC, or 10GE interface configurable
• 1010GE mapping into OTU-2 acc. G.709, standard G.709 FEC or Super-FEC for enhanced reach
• Line interfaces also configurable as client interfaces
Client interfaces: Client module: Several client interfaces (SFP for 1GbE, SFP+ for 10GbE), 10GbE PHY for 10GbE interfaces, Client CPLD for SFP/SFP+, LED handling
• up to 22 client ports possible in flexible configuration
• 16x 1GE and 2x 10GE client interfaces (up to 4 additional 10GE can be configured from line ports)
• Any port usable as UNI or NNI
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
85
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For internal use
Metro CET Ethernet switch I22CE10G
DWDM XFP
SFP+
DWDM SFP
DWDM SFPClient interface:
16 x GE and
2 x 10GE (+hybrid IFs)
76G Ethernet switch capacity (California Count 152G) Card protection option and ext. switching capacity via stacking of L2 cards 4x hybrid OTU-2 / 10GE interfaces (configurable trunk or client) 16x 1GE and 2x 10GE client interfaces, statistical multiplex Line interfaces are 10GE mapped into OTU-2 with (Super)-FEC Support for connection oriented Ethernet Extended VLAN support L2 MPLS support (R4.4) E-LINE and E-LAN services acc. MEF-6
2 slot card
SFP+
DWDM XFP
DWDM XFP
DWDM XFP
16x…
2x…
4 line interfaces
OTU-2or
10GE
(opt. configurable
as client IF)
…
Fig. 76 L2 Switch card I22CE10G
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 86
2.5.1.7 I0xT40G Card
With release R4.25 SURPASS hiT 7300 supports the new 40G transponder cards
• I01T40G 40Gbit/s on client interface
• I04T40G 4x 10Gbit/s on client interface
• I01R40G 40Gbit/s unidirectional regenerator card
• I02R40G-2/CQP 40Gbit/s bidirectional regenerator card for CP-QPSK
From these cards there are different sub types:
• I0xT40G-1/DP DPSK modulation
• I0xT40G-1/DPS DPSK modulation for sea cable
• I0xT40G-1/CQP CP-QPSK modulation
• I01T40G-2/CQP-I CP-QPSK modulation with intra office (2km) client interface
• I01T40G-2/CQPS-I CP-QPSK modulation for sea cable with intra office (2km) client interface
• I01T40G-2/CQP-S CP-QPSK modulation with short reach (10km) client interface
• I01T40G-2/CQPS-I CP-QPSK modulation for sea cable with short reach (10km) client interface
The 40G cards which are fully integrated within the hiT 7300 mechanical shelf and rack solution and which is fully managed by the hiT 7300 NE controller. In R4.30, line protection with the new O02CSP-1 card is introduced.
These cards use on the line interface OTU3v with Super-FEC.
The I01T40G card provides the following traffic interfaces:
• 1x STM-258/OC-768, or
• 1x OTU-3 (w/ standard FEC insertion)
The I04T40G card provides the following traffic interface:
• 4x STM-64/OC-192, or
• 4x 10GE (10GBASE-R/-W, GBE LAN semitransparent), or
• 4x OTU-2 (w/ standard FEC insertion)
• Arbitrary mix of service types on client
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
87
I01T40G-140G Transponder Card
• 40 Gb/s Transponder with OTU-3 support • Adaptive DPSK modulation format, full C band tunable laser• Integrated dispersion compensation unit and pre-amplifier • Optional external polarization mode dispersion (PMD) compensator• Super Forward Error Correction (Super-FEC) on line side, appr. 8dB coding gain• Services supported
•STM-256 / OC-768•OTU-3
Fully integrated card
Line interface
1 x OTU-3Line MSA
(DPSK)
I01T40G-1
OTU-3 Framerand Mapper
TDCM
Client interfaces
1 x OTU-3 or1 x STM-256/OC-768
XFP
Fig. 77 40G Transponder Card I01T40G
For internal use
I04T40G-140G Muxponder Card
• 40 Gb/s Transponder with OTU-3 support
• Adaptive DPSK modulation format, full C band tunable laser
• Integrated dispersion compensation unit and pre-amplifier
• Optional external polarization mode dispersion (PMD) compensator
• Super Forward Error Correction (Super-FEC) on line side with 7% overhead
• 4 x grey/C/DWDM XFP based client ports:
• 4x STM-64/OC-192 or
•4x 10 GbE LAN or 10GbE WAN or
•4x OTU-2 (with FEC )
•or mixed configuration
Fully integrated card
Client interfaces
4 x STM-64/OC-192 or
4 x OTU-2 or
4 x 10GE or
any mix
Line interface
1 x OTU-3Line MSA
(DPSK)
I04T40G-1
OTU-3 Framer
and Mapper TDCM
(DWDM) XFP
(DWDM) XFP
(DWDM) XFP
(DWDM) XFP
Fig. 78 40G Muxponder Card I04T40G
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 88
I0xR40G-140G Regenerator Card
• I01R40G-1 is a unidirectional regenerator card• I02R40G-2/CQP is a bidirectional regenerator card for CP-QPSK• 40 Gbit/sec unidirectional regenerator function via OTU-3 line interface (DPSK
modulation format) • Bidirectional regenerator function provided via 2 cards in adjacent slots
Fully integrated card
Line interface
1 x OTU-3Line MSA
(DPSK)
I0xR40G-1OTU-3 Framer
and Mapper
TDCM
Fig. 79 40G Regenerator Card I0xR40G
Fig. 80 40G Muxponder Card I04T40G
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
89
2.6 hiT7300 Optical Protection hiT7300 supports the following traffic protection options:
For internal use
O02CSP +any amplifier
O02CSP +any transponder
I04T2G5I04TQ10G
O02CSP/ O03CP +any transponder
Protection options
Cos
t
Network availability
Protection on UNI client ,node disjoint DWDM routing by TransNet
Various protection levels offeroptimized CAPEX for each required availability level
1+1 Optical path protection,
intra card
1+1 Optical path protection
inter card
1+1 span protection
O02CSP + opt. filters (future release)
1+1 OMS protection
I05AD10G1+1 Service Channel protection intra card
1+1 optical channel protection
Fig. 81 hiT7300 Protection options
These options are:
• 1+1 Line protection without transponder protection
• 1+1 Service Channel protection without transponder protection
• 1+1 Optical Channel protection without transponder protection
• 1+1 Optical Channel protection with transponder protection
• 1+1 OMS protection
• 1+1 span protection
In order to achieve reasonable traffic survivability, working and protection paths of the OCh should be routed over physically diverse optical multiplex sections, which means that the necessary optical equipment (opt. multiplexer/de-multiplexer, opt. Amplifier) must be doubled.
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 90
1+1 Line protection without transponder protection
Protects against Fibre cut, degradation on the optical line
Protection against any failure of the optical system (filters, ROADM, amplifiers)
Does not protect against any transponder failures
Characteristics• Protects the transponder line signal
• O02CSP protection card with transmit side splitter, receive side switch
Tra
nspo
nder
Tra
nsp
ond
er
Lowest cost protection; best used for 40G transponder protection to avoid doubling expensive 40G transponders
O02CSP
OpticalProtection
Switch
Fig. 82 hiT7300 Protection options
For internal use
I05AD10G
1+1 Service Channel protection without transponder protection
Protects against Fibre cut, degradation on the optical line
Equipment failures of all cards in the optical system (filters, ROADM, amplifiers) and of the transponder line interface (line side XFP)
Ideal for transport of GE services;can be combined with drop & continue for multicast
Client processing
Mux/Demux
Mux/Demux
Muxponder card
Client 1
Client 2Client
processing
Characteristics Protection of the transponder’s
optical client side, i.e. each individual client signal can be protected by one electrical protection switch
Dual line side of transponder card I05AD10G is used as working and protection line sides
No dedicated protection card necessary
Fig. 83 hiT7300 Protection options
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
91
1+1 Optical Channel protection without transponder protection
Protects against Fibre cut, degradation on the optical line
Equipment failures of all cards in the optical system (filters, ROADM, amplifiers) and of the transponder line interface (line side SFP)
Characteristics Protection of the transponder’s
optical line side, i.e. the complete transponder line signal is protected by one electrical protection switch
Dual line side of transponder card I04T2G5 is used as working and protection line sides
No dedicated protection card necessary
I04T2G5
Ideal for transport of GE services
Mux/Demux
Line processing
Line processing
Muxponder card
Client 1
Client 2
Fig. 84 hiT7300 Protection options
O03CP
1+1 Optical Channel protection with transponder protectionCharacteristics• Protection on client side of the transponder
• For all 10/40G transponder cards
• One O03CP card protects up to 3 bi-directional signals
Protects against• Fibre cut, degradation on the optical line
• Full transponder protection, and protection against any failure of the optical system (filters, ROADM, amplifiers)
Tra
nspo
nder
Tra
nspo
nder
Tra
nspon
derT
ransp
onder
Ideal for protection of highest value leased lines
OpticalProtection
Switch
Fig. 85 hiT7300 Protection options
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 92
2.6.1 O02CSP-1, Dual protection card
Protection and compensator cards for OCh protection schemes are complemented in R4.30 by a dual protection card which contains two 2x1 switches and two power splitters. The O02CSP-1 in cooperation with one interface card will perform a 1+1 Line Side Optical Channel Protection (LS-OChP). The switching will be done actively by the O02CSP-1 card using an optical switch. In contrast, the O03CP is a purely passive card.
This is a 1-slot wide active card for two bidirectional 2-port channel protection units, each consisting of a splitter and a switch. All the inputs and the output of the switch are supervised by LOS monitors. The card is usable for line protection via the splitter and the switch. Within the actual version, the switch decision could be triggered by both; the operator via CCEP or autonomously via LOS detection. All LOS evaluation for the O02CSP is based on its own decisions. No communication is available between O02CSP and any other transponder card in 4.30. Hence, the O02CSP can handle any transponder. In addition to line side protection, the O02CSP-1 can also be used on the client side of a muxponder, as loss forwarding will be supported in 4.30. The protection has to be configured via LCT
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
93
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
O02CSP-1 Dual Protection CardO02CSP-1 Dual Protection Card
Fig. 86 O02CSP-1, Dual protection card
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 94
2.6.2 O03CP-1, Optical channel protection card
A 1+1 ODU1 protection (ODU1P trail protection) is completely realized on the 2G5 transponder card I04T2G5 1 for a corresponding pair of working/protection OTU1 line interfaces on one transponder card. Protection switching is done on the electrical signal level for the ODU1 signal transmitted/received at the line side.
A 1+1 client protection of OTU2 Channels is realized by a pair of 10G muxponder cards I08T10G 1 or/and. transponder cards I01T10G 1 equipped in adjacent slots together with optical protection cards O03CP 1. Protection switching is done by on/off switching of the client laser at the transponder card. Only the client laser of the active path is enabled, the client laser of the protecting path is switched off. This requires communication between the two transponder cards. The active and the protecting path are combined at the O03CP 1 card.
As an example for the possible slot assignment of the muxponder/transponder cards see the following table:
Slot N. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1+1 client I08T10G-1
W P W P W P
1+1 client I01T10G-1
W P W P W P W P W P W P W P
The OChP card O03CP-1 is a passive card which contains 6 optical splitters. Three act as combiners to switch the traffic together with the 10 Gbit/s transponder cards. The remaining three are used for bridging the traffic for protection.
Up to three protection groups can be created and managed by the O03CP-1 card (i.e., three pairs of 10 Gbit/s transponder cards).
The O03CP 1 is a passive card.
The following table is giving the OChP card overview:
Card name Number of protected channels
Architecture Communication type
O03CP-1 3 3 splitters and 3
combiners bidirectional
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
95
O03CP-1
Client 1 IN
3 d
B S
pli
tter
Wo
rkin
g 1
OU
T
Pro
tect
ion
1
OU
T
Co
mb
iner
Wo
rkin
g 1
IN
Pro
tect
ion
1
IN
Client 1 OUT
Client 2 IN
3 d
B S
pli
tter
Wo
rkin
g 2
OU
T
Pro
tect
ion
2
OU
T
Co
mb
iner
Wo
rkin
g 2
IN
Pro
tect
ion
2
IN
Client 2 OUT
Client 3 IN
3 d
B S
pli
tter
Wo
rkin
g 3
OU
T
Pro
tect
ion
3
OU
T
Co
mb
iner
Wo
rkin
g 3
IN
Pro
tect
ion
3
IN
Client 3 OUT
Fig. 87 O03CP-1, Optical channel protection card
Fig. 88 Possible slot assignment for transponder cards working as a protection pairs
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 96
2.7 System management Function
2.7.1 Optical Supervisory Channel
SURPASS hiT7300 offers a 12.5 Mbit/s (≤ 4.30) or 150 Mbit/s (≥ 5.0) bandwidth Optical Supervisory Channel (OSC) to provide communications between all SURPASS hiT7300 NE's within OMS and OTS trails.
The optical supervisory channel is used for all data communication as needed for the configuration, fault management, performance management, as well as for any software management required to setup and maintain the NE's of the OTN.
The OSC is a bidirectional data channel whereby the same wavelength of 1510 nm is used for both transmission directions, each on a separate fiber. The OSC wavelength lies just outside the C-Band of the used optical channel wavelengths, and is terminated at each hiT7300 network element (ONN and OLR). Therefore, even in the rare occurrence of an optical amplifier failure, the OSC and hence all management communications remain intact.
The high optical performance of the OSC supports very long spans for up to 50 dB span attenuation at 1510 nm out-of-band OSC wavelength (corresponds to ~48.5 dB span attenuation for traffic wavelengths within C-Band) using LALBCH-1 booster amplifier card.
TIP Since the version 5.0 the resilience of the OSC channel will be also improved by the FEC mechanism known from the transponder cards
The following table shows an overview of the functions supported by the OSC:
Optical Supervisory Channel (OSC) Functions:
Data communication channel for the internal Data Communications Network DCN (Ethernet based);
Link control information for initializing and maintaining of the optical OMS/OTS trails (e.g. number of equipped channels, current link states, etc.);
Control Information for Automatic Power Shutdown (APSD);
Two bidirectional User Channels (Ethernet based);
Two Engineering Orderwire (EOW) channels;
Trace Identifier for the optical OMS/OTS trail;
Forward / Backward Defect Indication (FDI / BDI) within OMS/OTS.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
97
Q (LAN) Interface
ONN
NEController
NEController
OLR
NEController
NEController
ONN
NEController
NEController
ONN
NEController
NEController
TNMS
LCT
QF Interface
OSC (1510nm)
OSC (1510nm)
OSC (1510nm)
Fig. 89 Optical Supervisory Channel
Fig. 90 Optical Supervisory Channel (OSC) Functions
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 98
2.7.2 Generic Communication Channels
The SURPASS hiT 7300 supports Generic Communication Channels of GCC0 type according to ITU-T G.709 for OTU-k interfaces of the SURPASS hiT 7300 transponder cards. The GCC0 channels can be used to extend the internal DCN of a transport network or for transmission of user channels in any customer specific application.
The GCC0 channels can be preferably used for data communication over passive CWDM/DWDM links or non-colored (grey) single channels, where no OSC channel exists for these purposes.
Bandwidth of GCC0:
• OTU1 GCC0 326 kbit/s
• OTU2 GCC0 1.3 Mbit/s
• OTU3 GCC0 5.2 Mbit/s
A maximum of 1 GCC0 channels (OTU-2) and 4 GCC0 channels (OTU-1) are supported per transponder card. All the configured channels must belong either to the client(s) or the line(s) interface of the card.
A maximum of 26 GCC0 channels are supported per NE.
In the GCC0 channel two types of communication protocols are supported, which are configurable per NE:
• SURPASS hiT 7300 GCC0 mode: a GCC0 channel transports one internal DCN channel (as part of the SURPASS hiT 7300 internal DCN) and two user channels, all consisting of tagged Ethernet frames.
• SURPASS hiT 7500 GCC0 mode: a GCC0 channel transports one internal DCN channel for communication within a SURPASS hiT 7500 internal DCN, using an IP over PPP protocol stack compatible with SURPASS hiT 7500; this mode can be used for applications using a SURPASS hiT 7300 SON NE (as a remote network termination) with SURPASS hiT 7300 transponder cards as a feeder for a SURPASS hiT 7500 transmission network.
TIP Each GCC0 channel supports two transparent Ethernet based user channels (in SURPASS hiT 7300 mode), which can be externally accessed by two RJ45 connectors on the controller card within the shelf containing the respective transponder card terminating the GCC0 channel.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
99
● Generic Communication Channels of GCC0 type according to ITU-T G.709 ● GCC0 channels can be preferably used for data communication over
passive CWDM/DWDM links ● Each GCC0 channel offers a bandwidth of 326 Kbit/s in OTU1 transponders
(e.g., I04T2G5-1) and 1.3 Mbit/s in OTU2 transponders (e.g., I01T10G-1).● A maximum of 1 GCC0 channels (OTU-2) and 4 GCC0 channels (OTU-1)
are supported per transponder card ● All the configured channels must belong either to the client(s) or
the line(s) interface of the card ● A maximum of 26 GCC0 channels are supported per NE
hiT 7300 GCC (Generic Communication Channel FactshiT 7300 GCC (Generic Communication Channel Facts
Fig. 91
Q (LAN) Interface
SON
NEController
NEController
SON
NEController
NEController
SON
NEController
NEController
TNMS
LCT
QF Interface
OpticalLine
OCUOCUOCUOCUOCUOCUOCUOCUOCUOCUOCUOCU
OCUOCUOCUOCUOCUOCU
OpticalLine
Fig. 92 Example of usage Generic Communication Channels
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 100
2.7.3 Control and management Function
Optical link control is intended to ensure optimized optical link operation in any link state. The goals are to maintain sufficient link performance and consequently an equally distributed power level (with reference to the containing OSNR value) at each channel's tail end (at optical receiver or regenerator locations). Within each individual NE, the Controller card serves as central instance to manage and control all optical link relevant information. Controller cards within an optical link must exchange management information as well as measurement data between each other.
Two different types of link control are available since version 5.0:
• EPC: Enhanced Power Control this is the legacy behavior of the hiT7300.
• APC: Advanced Power Control is the behavior of the hiT7300 DCM free network (96 channels). The advantages are faster measurement cycles more automatic features.
TIP Link management information and measurement data needed for controlling the optical link is exchanged between NE's via the optical supervisory channel.
NE external communication links and NE internal communication links are established to properly operate all optical link control mechanisms for the whole link and within the NE.
Within each shelf the Controller card communicates, with all "passive" cards (e.g., filter and attenuator cards), using the I2C bus. "Active" cards (e.g., line amplifier and Raman pump cards) use the amplifier-pump control bus to communicate with the Controller card.
The communication between shelves is achieved with two Ethernet LAN connectors on the Controller card.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
101
ControllerCard
OSC OSC OSC
ONN-T OLR ONN-T
OSC OSC OSC
ONN-S
ControllerCard
ControllerCard
ControllerCard
Optical Link A Optical Link B
Fig. 93 Optical link control
1 2 3 14 15 16
Sh
elf
Co
ntr
oll
er
I²C bus
Amplifier-Pump Control bus
Shelf
1 2 3 14 15 16
Mai
nC
on
tro
ller
Master Shelf
Card Slots
. . .
Card Slots
. . . NE
inte
rnal
Eth
ern
et
I²C bus
Amplifier-Pump Control bus
atte
nu
ato
r ca
rd
filt
er c
ard
filt
er c
ard
filt
er c
ard
filt
er c
ard
filt
er c
ard
Ram
anam
plif
ier
amp
lifie
r
Ram
anam
plif
ier
amp
lifie
r
hiT7300 NE
Fig. 94 NE internal communication
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 102
2.7.4 Data Communication Network
The Data Communication Network (DCN) provides TMN access, via Ethernet interfaces Q and QF using SNMPv3, TL1 and HTTP protocols, to all the NE's within one sub-network. The Q interface allows the SURPASS hiT7300 system to be connected to a TMN system, e.g., TNMS. The QF interface has a pre-configured IP address for a direct local connection to the LCT. The LCT obtains its IP address from a DHCP / DNS server on the NE. In addition to the Ethernet interfaces of the NE's, the underlying DCN provides interconnected Data Communication Channels (DCC) to operate all connected NE's.
The services provided by the DCN are:
• Separate the DCN from the customer IP network via NAT-P.
• Software download/distribution via FTP.
• Pre-emphasis and file distribution control based on XML-RPC.
• User channels with point-to-point Ethernet channel per link.
• Time synchronization via Network Time Protocol (NTP).
• Domain Name Service (DNS).
• Dynamic Host Configuration Protocol (DHCP).
The following management protocols are provided by the hiT7300 NE:
SNMP V3 Protocol between NE's and TNMS Core/ TNMS CT/ @CT is used as a direct interface to customer OS
HTTP.1 Used by Web-based LCT - called @CT - and offers a fully functional Element Manager for commissioning or maintenance of a NE.
FTP(S) Used for file transfer (e.g. PM/alarm data, SW download and etc.)
TL1 Used for Network management acc. Telcordia standards.
2.7.4.1 Gateway Function (GF) of NE
The Gateway Function (GF) provides one single IP address for a sub-network and is the connection point between NE and a network management system. The GF then maps different TCP ports to different NE's with internal IP addresses in this sub-network; implements a Network Address Translation Port forwarding (NAT-P) to hide the DCN internal IP addresses from the carrier data network and a FTP proxy for file transfer between an external FTP server and the NE's. The GF separates the embedded DCN from the customer DCN.
At least two Gateway Functions (GF) should be implemented on different NE's which provides redundant access to the SURPASS hiT7300 DCN.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
103
The services provided by the DCN are:
● Separate the DCN from the customer IP network via NAT-P.● Software download/distribution via FTP.● Pre-emphasis and file distribution control based on XML-RPC.● User channels with point-to-point Ethernet channel per link.● Time synchronization via Network Time Protocol (NTP).● Domain Name Service (DNS).● Dynamic Host Configuration Protocol (DHCP).
Fig. 95 hiT7300 DCN services
Management protocols are provided by the hiT7300:
Fig. 96 hiT7300management protocols
DHCP provides all NE’s with internal IP address, NAT-P then maps different TCP
ports to the different NE IP‘s to hide the internal DCN
DHCP provides all NE’s with internal IP address, NAT-P then maps different TCP
ports to the different NE IP‘s to hide the internal DCN
At least two GW NE‘s should be implemented
to provide redundant access to the DCN
At least two GW NE‘s should be implemented
to provide redundant access to the DCN
Q interface connects hiT7300 Network
(static connection) to TNMS
Q interface connects hiT7300 Network
(static connection) to TNMS
TCP/IP Network
TNMS C
DCCDCC DCC
Non-GW NE
QF interface
SNMPv3 HTTP FTP
UDP TCP
Eth (MAC)
Eth (PHY)10/100 base-T
OSC( 12.5 Mb/s)
IPv4 (w/o routing )
The DCN Protocol Stack of the hiT7300 NE’s
@-CT
TNMS CT
Q interface(GW function)
Q interface(GW function)
Non-GW NE
DCN provides interconnected Data Communication
Channels (DCC) to operate all connected NE's
DCN provides interconnected Data Communication
Channels (DCC) to operate all connected NE's
The QF interface has a pre-configured IP address (DHCP / DNS server) for direct local
connection to the @ LCT (temporary GW function)
The QF interface has a pre-configured IP address (DHCP / DNS server) for direct local
connection to the @ LCT (temporary GW function)
The protection switching is initiated by TNMS by inspecting the NE
reachability via different gateways
The protection switching is initiated by TNMS by inspecting the NE
reachability via different gateways TL1
Fig. 97 hiT7300 Data Communication Network
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 104
The SURPASS hiT7300 DCN network is implemented as a switched network and the Message Communication Function (MCF) is implemented as a L2 switch.
A network of interconnected NE's is designated a DCN domain. The communication is established via the OSC of the optical links and an Ethernet/L2 switching network implemented by the NE's (MCF). A single DCN domain supports up to of 118 NE's.
TIP To maintain a loop-free topology of a switched DCN network/sub-network, the SURPASS hiT7300 supports the Spanning Tree Protocol (STP).
The connection to the Local Craft Terminal (LCT) and/or the TNMS-C can be done via the Ethernet ports (Q interface) on the CCEP/CCMP controller card. The QF interface has a preconfigured (via DHCP/DNS service) IP address for connecting the LCT. The Q port is normally reserved for the TNMS. If the Q port is used for DCN interconnection with another NE a second IP address can be assigned to the QF port.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
105
TCP/IP Network
TNMS
Q interface(GW function)
Designated DCN domain.
The communication is established via the OSC (DCC) of the optical links and
an Ethernet/L2 switching network implemented by the NE's (MCF).
A single DCN domain supports up to of 118 NE's.
To maintain a loop-free topology of a switched DCN network/sub-network,
the SURPASS hiT7300 supports the Spanning Tree Protocol (STP)
DCCDCC DCC
MCF MCF MCF MCFMCF
TNMS CT
DCCDCC
MCF
L2 Switch
Q/QF
DCC DCCDCC
MCFMCFMCFMCF MCF
DC
C
DC
C
Q interface(GW function)
STP is active
STP is active
Fig. 98 Data Communication Network
If the Q port is used for DCN interconnection with
another NE a second IP address can be assigned to the QF port for GW function.
If the Q port is used for DCN interconnection with
another NE a second IP address can be assigned to the QF port for GW function.
TCP/IP NetworkTNMS C
DCCDCC
Ethernet cableQ interface
QF interface(GW function)
Both NE‘s are in the same location
Q interface
If the Q port is used for DCN interconnection with
another NE a second IP address can be assigned to the QF port for GW function.
If the Q port is used for DCN interconnection with
another NE a second IP address can be assigned to the QF port for GW function.
Designated DCN domain
Fig. 99 Usage of the Q port for DCN interconnection
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 106
2.7.4.2 Multi-Domain DCN
A network of interconnected NE's is designated a DCN domain. The communication is established via the OSC of the optical links and an Ethernet/L2 switching network implemented by the NE's (Message Control Function (MCF)).
A single DCN domain supports up to 118 NE's managed via a SNMP TMN system or up to 50 NE's managed via a TL1 TMN system.
The SURPASS hiT 7300 system supports the partitioning of large DCN networks into smaller DCN sub-networks limited between them by border-NEs which allow a separation of L2 switching domains.
Each L2 switching domain has its own gateway NE(s) for communication with the TMN system via the carrier data network. These multi-domain DCN's are characterized by:
• Up to 16 DCN sub-networks, with a maximum of 118 NE's (via SNMP) or 50 NE's (via TL1) per L2 domain can be configured.
• Within an L2 domain the DCN traffic is switched, and at the domain borders all L2broadcast traffic is terminated.
• Border-NE's can connect up to 3 L2 domains.
• Border-NE's can be configured as gateway NE's to provide all the DCN services (e.g., NAT-P, FTP). These services may run in multiple instances to support multiple L2 domains.
• Border-NE's can have distinct NE roles (e.g., primary gateway NE, client DHCP) for each DCN sub-network.
• In-service upgrade from a single to a multi-domain DCN network is possible.
• Optical enhanced pre-emphasis control is also possible for links where both NE's belong to different L2 domains.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
107
● Up to 16 DCN sub-networks, with a maximum of 118 NE's (via SNMP) or 50 NE's (via TL1) per L2 domain can be configured
● Within an L2 domain the DCN traffic is switched, and at the domain borders all L2 broadcast traffic is terminated
● Border-NE's can connect up to 3 L2 domains ● Border-NE's can be configured as gateway NE's to provide all the DCN services (e.g., NAT-P, FTP).
These services may run in multiple instances to support multiple L2 domains ● Border-NE's can have distinct NE roles (e.g., primary gateway NE, client DHCP)
for each DCN sub-network ● In-service upgrade from a single to a multi-domain DCN network is possible
● Optical enhanced pre-emphasis control is also possible for links where both NE's belong to different L2 domains
Multi-Domain DCNMulti-Domain DCN
Fig. 100
hiT7300 gateway NE with DHCP (Primary/Secondary) server
hiT7300 (domain) border-NE
Carrier Data Network
Q
L2Domain1
L2Domain3
L2Domain2
DHCP_P DHCP_S
DHCP_P DHCP_S
DHCP_P DHCP_S
DHCP_P/S
Q Q Q
hiT7300 NE as local (temporary) gateway for @CT
hiT7300 target NE
Fig. 101
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 108
2.7.5 Network Time Protocol
The NTP is used for time synchronization of the DCN. When synchronized, all NE's use the same reference clock for time stamping of log entries, issued events, etc. The NE's in the DCN rely on the NE's configured as DHCP servers for time synchronization, i.e., they use the DHCP servers as NTP servers.
The NE's configured as DHCP servers must use external NTP (up to three) servers in the customer network for time synchronization.
The NE chooses the actual NTP server among the available servers, since NTP protocol allows redundant time synchronization.
If no NTP server is available (external or DHCP server), the NE goes into a free-running mode, depending only on its internal clock.
hiT7300 NetworkhiT7300 Network
Customer NetworkNTPServer
Router
NTPServer
ONN-T (GW&DHCP)
ONN-T (GW&DHCP)
Router
TNMS
OSC OSC OSC OSC OSC
Worker Standby
Clock Synchronization direction
OLROLR OLROLR ONN-T (GW)ONN-T (GW)ONN-IONN-I ONN-SONN-S
Fig. 102 Network Time Protocol
TIP In multi-domain topologies, border-NE's which are configured as DHCP clients, obtain time synchronization from all DHCP server NE's (i.e., DHCP servers from all the network domains) by selecting the best reference time.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
109
2.7.6 Engineering Order Wire interface
The EOW interface can be used to establish conference and selective calls from one NE to other NE(s) using a handset.
When plugged, a handset is automatically in the same conference call of all the other handsets connected to the same line. The communication line is built from all shelves, belonging to different NE's, which are interconnected by OSC's.
In case of a selective call the operator selects an NE by dialing a 3-digit number, which is configured via LCT.
EOW calls are carried over OSC and transmitted together with the OSC payload via the optical fiber along the entire transmission line.
In ring and meshed networks, the line may form a closed ring. A ring manager opens the loop, to prevent the EOW call from feedback distortion.
Inter-shelf EOW connection in multi-degree ONN's is achieved with a 4-wire cable that interconnects the controller cards of different shelves belonging to the same NE. This allows EOW calls in interconnected rings and meshed networks
HandsetsHandsetsHandsetsHandsetsHandsetsHandsets
Ring Manager should be enabled e.g. in this NE to avoid distortion
Ring Manager should be enabled e.g. in this NE to avoid distortion
Connections via 4-wire interface between the NE’s pertaining two
different optical links.
Connections via 4-wire interface between the NE’s pertaining two
different optical links.
Fig. 103 Engineering Order Wire interface
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 110
2.7.7 User channels
The SURPASS hiT 7300 user channels (each 10 Mbit/s) are used for bidirectional connections between NE's via the OSC or GCC0, providing the customer with a point-to-point Ethernet connection for specific data network or remote access to NE's not reachable via DCN. The user channels are accessible via two Ethernet ports, User 1 and User 2.
Up to two user channels (belonging to different spans) can be terminated on each controller card. If both user channels belong to the same span only one user channel can be terminated. Transit user channels (i.e., transfer traffic routed to another span) are forwarded to the respective span by the NE shelf controller.
The actual number of user channels that can be used in an NE depends on the number of transponders and line amplifier cards configured with OTU-k. Per NE a maximum of 26 GCC0 channels and 8 OSC channels is supported, each carrying two user channels.
In ONN's, the user channels are terminated by default. However, they can be set to through connected via LCT (within the same controller card) or by interconnecting the User 1/User 2 connectors (of different controller cards) via an Ethernet cable. In OLR's, the user channels are through connected by default. Using LCT, the through connection can be opened and the user channels are accessible at OLR's also.
UC2 portUC2 port
Patch cord
Patch cord
ONN-TONN-T OLROLR OLROLR ONN-IONN-I ONN-TONN-T
UC2 portUC2 portUC1 portUC1 port UC2 portUC2 port
UC1 portUC1 portUC2 portUC2 port
Fig. 104 User channels
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
111
2.7.8 Telemetry Interface
The TIF sensors (inputs) and TIF actors (outputs) are intended to be used for traditional user-defined “housekeeping” purposes. The TIF sensors usually supervise particular events at the site (e.g., fire alarm, over-temperature alarm, door-open alarm, etc.) and carry alarms issued by external equipment (e.g., StrataLight OTS-4000 and MPBC RMH07 series). The TIF actors usually control particular devices at the site (e.g., lights, air conditioning, etc.).
TIF sensors and actors are available on the first shelf (001) of the CCEP-1 controller card with 16 sensors and 15 actors. Actors, 1 to 8, are free to be used by the user. The remaining actors, 9 to 15, are used for equipment/communication alarm indication purposes, visible and audible. The TIF sensors generate an environmental alarm on the NE, when the current state differs from the configurable normal state.
TIF actors Description
TIF Actors, 1 to 8 Free to be used by the user
TIF actor 9 Critical Alarms (audible)
TIF actor 10 Major Alarms (audible)
TIF actor 11 Minor Alarms (audible)
TIF actor 12 Critical Alarms (visible)
TIF actor 13 Major Alarms (visible)
TIF actor 14 Minor Alarms (visible)
TIF actor 15 Power Equipment Alarm
TIF sensors and actors are available on the CCEP-1 controller card with 16 sensors and 15 actors; TIF sensors supervise events and TIF actors control devices. TIF actors can be used as follow:
Fig. 105 TIF Actors
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 112
2.7.9 Controller Cards functions
Each shelf is to be equipped with a controller card at a dedicated slot position. There is always one main shelf which includes the NE controller and there can be several extension shelves which have a shelf controller. The controller cards act as a NE controller on the main shelf and the sub-shelves, mainly providing NE central interfaces and functions.
The Controller cards provide the central monitoring and control functions for the system, as well as the MCF to operate the Q and QF communication interfaces. Using these interfaces, the Controller card performs the following main functions:
• Fault Management:
Monitoring all system alarms and forwarding their states to the network management system.
• Performance Management:
On request, sending all optical performance management information to the network management system and/or a craft terminal.
• Configuration Management:
Configuring the system to either default settings or to persistently stored settings initiated by the network management system and/or a craft terminal.
• Security Management:
Controlling the individual access via the network management system and/or a craft terminal to particular NE functions, using a hierarchical security management user ID and password concept.
• Equipment Management:
Monitoring the actual and required shelf equipping.
• Communication Management:
Implementing the MCF for the communication between all NE's and the network management system.
• Software Management:
Performing all software downloads, uploads, and software integrity functions.
• Real Time Management:
Controlling the real-time clock.
• Providing alarm outputs from shelves and racks.
• Controlling the NE alarm LED's (e.g., major/minor, for communication and equipment alarms).
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
113
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Controller card performs the following main functions:
● Fault Management: Monitoring all system alarms and forwarding their states to the network management system.
● Performance Management: On request, sending all optical performance management information to the network management system and / or a craft terminal.
● Configuration Management: Configuring the system to either default settings or to persistently stored settings initiated by the network management system and/or a craft terminal.
● Security Management: Controlling the individual access via the network management system and/or a craft terminal to particular NE functions, using a hierarchical security management user ID and password concept.
● Equipment Management: Monitoring the actual and required shelf equipping.
● Software Management: Performing all software downloads, uploads, and software integrity functions.
● Real Time Management: Controlling the real-time clock.
● Providing alarm outputs from shelves and racks.
● Controlling the NE alarm LED's (e.g., major/minor, for communication and equipment alarms).
Fig. 106 Controller cards main functions
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 114
2.7.10 Controller Cards types
Three types of controller cards are available as described below:
• CCEP-1, NE and main shelf controller card with TIF/Alarm interfaces;
• CCEP-2, NE and main shelf controller card with TIF/Alarm interfaces; necessary for GMPLS
• CCMP-1, NE and main shelf controller card without TIF/Alarm interfaces;
• CCMP-1, NE and main shelf controller card without TIF/Alarm interfaces; necessary for GMPLS
• CCSP-1, extension shelf controller card.
The CCEP and CCMP controller cards consist of the same controller card motherboard, where only the CCEP includes an additional module for TIF/Alarm interfaces. Both CCEP and CCMP can be equipped in the main shelf for operation as the NE controller card and providing the external management interfaces (Q, QF) of the NE.
The CCSP card is equipped in each extension shelf of the hiT7300. The front plate of the CCSP card looks exactly as the CCMP card except that it has eliminated all the redundant functions (e.g. Q, QF interface) that are already available in the main controller card (CCEP/CCMP). This results in reduction of component and power supply requirement sufficient for management of an extension shelf.
The following table explains the external interfaces provided on the front panel of the controller cards:
Label on card Physical I/F Function
Fault LED (red) Fault indication of controller
OK LED (green) Service status of controller
UBAT 1 to 4 LED (green) Shelf power supervision
COM-AL (CRIT, MAJ, MIN)
LED (red, orange, yellow) Communication alarm status
EQUIP-AL (CRIT, MAJ, MIN)
LED (red, orange, yellow) Equipment alarm status
INFO LED (green / red) General Purpose Indication
RJ22 --- 4-pin RJ22 connector Handset connector
EOW D-SUB9 connector EOW shelf interconnection
USER 1 / USER 2 10/100BaseT, RJ45 connector
User channel 1 & 2 (point to point user channel connection)
ILAN 1 / ILAN 2 10/100BaseT, RJ45 connector
Internal LAN shelf connection 1 & 2 (connection between shelves)
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
115
CCSP
Lever
FaultOK
RJ 22
EOW
40 mm
ILAN 1
User 1
Q
ILAN 2
User 2
QF
D-S
UB
9
CRIT
MIN
UBAT
1
EQUIP-AL
234
TIF IN
30 mm
TIF OUT
/
Alarm
ACO
CRIT
COM- ALMINMAJ
MAJ
INFO
S U
B D
25
not onCCMP/CCSP
Lever
S U
B D
25
Fig. 107
Label on card Physical I/F Function
Q 10/100BaseT, RJ45 connector
Management Interface (not usable on CCSP)
QF 10/100BaseT, RJ45 connector
Management Interface (not usable on CCSP)
ACO LED (blue) Alarm Acknowledge Indication
ACO button Manual Alarm Acknowledge
TIFIN 16 TIF inputs, D-SUB25 connector
Telemetry Interface Inputs
TIFOUT / Alarm 8 TIF outputs + 6 outputs for TIF or external alarms + 1 power alarm output, D-SUB25 connector
Telemetry Interface Outputs, TIF or External Station Alarms (audible/visible), External Power Alarm
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 116
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Controller Cards
CCEP CCMP CCSP
Fig. 108 Controller Cards
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
117
2.7.11 Scalable multi-controller architecture
hiT 7300 introduces a multi-controller architecture where the subagent controllers completely handle the controlled sub NE which improves performance of processing power intensive applications (e.g. optical GMPLS), as well as start-up performance. It ensures scalability of a network element (NE) when upgrading networks or introducing new functionality.
The multi-controller architecture distributes the total workload among several subsystem controller cards (CCEP/CCMP). One subsystem controller, known as the ‘master agent’, takes the role of the NE controller, provides management interfaces to the network and delegates tasks to the other controller cards. The other controller cards, known as ‘subagents’ - are only internally used in the NE, with each being responsible for a different set of shelves. The subagents only manage those cards assigned to the subsystem and perform tasks such as equipment management or performance monitoring.
Existing NE’s can be migrated from single-controller to multi-controller architectures and support both options. The new ONN-X96 MD-ROADM requires a multi-controller architecture, due to its large number of supported channels and degrees.
Scalable multi-controller architecture
Fig. 109
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 118
2.7.12 Optical Attenuator cards
SURPASS hiT7300 provides the O08VA-1 card as variable optical attenuator card for 8 unidirectional channels. Variable attenuators (VOA's) can be used for dynamic power adjustment as pre- and/or de-emphasis per optical channel or per subband.
Following table shows the technical parameters of O08VA-1 card.
O08VA-1 Technical Data
Attenuation range 0-22 dB
Operating Band 1528-1610 nm
Maximum Insertion loss 1.5 dB
Resolution 0.1 dB per step
Response time 10 ms
Power Handling per VOA channel < 21 dBm
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
119
O08VA-1IN1IN2IN3IN4IN6IN7IN8 IN5
OUT1OUT2OUT3OUT4OUT5OUT6OUT7OUT8
Fig. 110 Optical Attenuator card
Fig. 111 HW layout
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 120
2.7.13 Channel power monitor (MCP4x-x) card
The channel power monitor card MCP4x-x provides an in-service monitoring of the optical channel power levels. The card contains an Optical Spectrum Analyzer (OSA) for 40/80 channels, which is periodically connected to 4 optical input ports.
There is three different types of the channel power monitor card are available:
Card name Supported bit rates Usage
MCP404-1 2.5 Gbit/s; 10 Gbit/s; 40 Gbit/s
40 channels (within 100 GHz grid) monitoring
MCP404-2 2.5 Gbit/s; 10 Gbit/s 40 channels (within 100 GHz grid) monitoring
MCP4-1 2.5 Gbit/s; 10 Gbit/s; 40 Gbit/s
80 channels (within 50 GHz grid) monitoring
The MCP4x-x card is used for:
• In-service measurement of optical channel power levels of the 40 channels on a 100 GHz grid at the source monitoring output port which is used for all optical amplifier card types as well as for the OSC termination card (LIFB-1).
• Measurement of an automated enhanced pre-emphasis configuration on an optical pre-emphasis section (i.e., a link with full channel multiplexing/demultiplexing). Using MCP4xx-x card at the beginning and end of a link in combination with an attenuator card, provides a fully automated optical link commissioning and an in service channel upgrade.
• Measurement of an automatic in-service amplifier tilt control. Using MCP4xx-x card at the beginning and end of a link, allows tilt correction values to be distributed over the whole link.
• Automatic performance measurement and supervision of optical carriers with autonomous start of measurement cycle every 300 seconds.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
121
There is three different types of the channel power monitor card are available:
The MCP4x-x card is used for:● In-service measurement of optical channel power levels of all channels● Measurement of an automated enhanced pre-emphasis configuration ● Measurement of an automatic in-service amplifier tilt control ● Automatic performance measurement and supervision of optical carriers
Fig. 112
MCP4x-x
Optical Spectrum Analyzer(OSA)
Optical Switch
Optical Coupler
MonP1
Tap 1Optical Coupler
MonP2
Tap 2Optical Coupler
MonP3
Tap 3Optical Coupler
MonP4
Tap 4
Fig. 113 Channel power monitor (MCP4x-x) card
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 122
2.7.14 Optical Transient Suppression Card (OTSC)
In addition, a new Optical Transient Suppression for C-band card (OTSC-1) is introduced. It provides Transient Suppression Channels (TSCh), which are permanently powered to prevent the build up of transients and can instantaneously replace power of dropped channels if most of the transmission channels are lost. The OTSC-1 placement is a good choice when the customer has extremely rigid requirements on transient behavior. If there are no specific requirements, the transient performance of hiT 7300 without OTSC-1 is sufficient.
The advantage of the OTSC-1 is that it allows the reduction of the planned transient margin in the link design, thus improving reach and lowering cost of the hardware. Additionally it can be added to any existing link to improve transient tolerance, without any other change of hardware required. The card offers the following functionality:
• 96 channel spectral range, suitable for DCM-free networks with 40G/100G CP-QPSK technology
• Transient protection for up to 80 traffic channels within the 96 channel plan
• 6 channels used for transient suppression channels, each with 2 x polarization multiplexed lasers (these channels are blocked for transmission – in addition, immediate adjacent channels are blocked as well, to optimize transient protection)
• 2 transient cards needed for each bi-directional Optical Multiplex Section (OMS) of the network (the transient channels are coupled in before the booster amplifier and blocked at the end of the OMS by the WSS)
• Enhanced transient performance of up to 10dB drops within 100ms
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
123
Fig. 114 HW layout
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 124
2.7.15 Flow Sensor Card (CFSU)
The CFSU card serves as a flow sensor unit to supervise the hiT 7300 shelf on sufficient air flow. The CFSU measures the amount of air flow through the shelf by also taking the absolute air pressure and the air temperature into consideration.
The CSFU card is an optional card which is useful in particular if a NE is installed within dusty environments in order to give an early indication on insufficient air flow due to a clogged dust filter within a hiT 7300 shelf. In order to ensure reliable measurement of the air flow, the CFSU card must be used in the high flow region of the fan to ensure maximum airflow conditions, for this purpose the card must always be plugged within slot #1 (left-most slot of a hiT 7300 shelf) and the right hand neighbor slot must not be empty.
The CFSU card included the following integrated sensors:
• Air flow sensor;
• Absolute air pressure sensor;
• Temperature sensor.
The CFSU card is optimized for the specific air filter media used in hiT 7300 standard shelf.
When the air flow is below a specific level this condition is alarmed so that the dust filter mat within the fan unit (CFS) of the hiT 7300 shelf should be replaced. Additionally there is a timer so that the filter mat is replaced after 6 up to 18 months of use anyway. At each cycle of determining the dust contamination of the dust filter mat all fans within the CFS fan tray are accelerated to top speed for 3 minutes and released to their normal operating speed afterwards. The time interval between each measurement cycle is configurable from 1 to 255 hours in steps of 1 hour.
At the front panel of the CFSU card there are 3 LED's for signaling different conditions and a button for restarting the 12 month timer.
• A red LED signals that a fault has occurred (CFSU card problem);
• A green LED signals faultless operation;
• A yellow LED signals that the dust filter mat has to be replaced;
TIP The restart button causes a restart of the 12 month timer when pressed for more than 5s.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
125
● The CFSU card measures the amount of air flow through the shelf;● The CSFU card is useful in particular if a NE is installed within dusty environments; ● The CFSU card included the following integrated sensors:
Air flow sensor; Absolute air pressure sensor; Temperature sensor.
● The CFSU card has a timer so that the filter mat is replaced after 6 up to 18 months of use anyway;
● CFSU card can also be used for management of dispersion compensation modules, which are plugged within external DCM shelves;
Flow Sensor Card (CFSU)
Fig. 115
Fig. 116 FSC
In addition to air flow supervision, the CFSU card can also be used for management of dispersion compensation modules which are plugged within external DCM shelves and therefore do not have a direct internal management interface to the NE controller (CCxP) of a NE. For this purpose the CFSU card provides a front panel connector (SUBD) for an electrical SPI interface which can optionally be connected to an external DCM shelf for access of up to 4 plugged dispersion compensation modules, which can then be managed by the NE controller.
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 126
2.7.16 Dispersion Module Management Card (CDMM)
The CDMM card can optionally be used for management of dispersion compensation modules which are plugged within external DCM shelves and therefore do not have a direct internal management interface to the NE controller (CCxP) of a NE. For this purpose the CDMM card provides a front panel connector (SUBD) for an electrical SPI interface which can optionally be connected to an external DCM shelf for access of up to 4 plugged dispersion compensation modules, which can then be managed by the NE controller.
The CDMM card can be used within any slot of a hiT 7300 standard shelf or a hiT 7300 flatpack shelf. The CDMM card occupies 1 slot (30mm).
● The CDMM card is used for management of dispersion compensation modules, which are plugged within external DCM shelves, where up to 4 plugged dispersion compensation modules can be managed by the NE controller .
● CDMM card provides a front panel connector (SUBD) for an electrical SPI interface. ● The CDMM card can be used within any slot of a hiT 7300 standard shelf
or a hiT 7300 flatpack shelf. ● The CDMM card occupies 1 slot.
Dispersion Module Management Card (CDMM)
Fig. 117
Fig. 118 CDMM Card
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
127
3 SURPASS hiT7300 NE Types
hiT 7300NE Types
!
Fig. 119 NE Types
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 128
SURPASS hiT7300 offers three basic Network Element Types which are:
• OLR – Optical Line Repeater;
• ONN – Optical Network Node;
• SON (SONF)– Standalone Optical Node.(Flatpack)
The following table lists all SURPASS hiT7300 available NE's types:
NE Subtype Description
OLR n.a. Optical Line Repeater
Used for optical signal amplification with dispersion compensation.
Terminates 2 spans.
ONN-T (80)
Optical termination node for realization of a Terminal 1/2 OADM with up to 40 (80) channels. Used for amplification, dispersion compensation, and full add/drop within an optical path.
ONN-I (80)
Optical interconnection node for realization of a FullAccess OADM or Flexible OADM with up to 40 (80) channels. Used for amplification, dispersion compensation, and full add/drop.
ONN-R (80)
Optical interconnection node for realization of a FullAccess OADM or Reconfigurable OADM (ROADM) with up to 40 (80) channels. Used for amplification, dispersion compensation, and partial or full add/drop.
ONN-R2 Cost optimized ROADM for 2 degree ONN with EOL 40 channel capacity. Used for amplification, dispersion compensation, and partial or full add/drop.
ONN-RT (80)
Tunable ROADM for 40 (80) channels. It has a limited add drop capacity of 8 ch @ EOL 40 or 16 ch @ EOL 80 channels.
ONN-S Optical interconnection node for realization of Small OADM. Used for amplification, dispersion compensation, and partial add/drop within a link.
ONN-X (80)
Optical interconnection node for realization of a PXC with up to 40 (80) channels. Used for amplification, dispersion compensation, and partial or full add/drop.
ONN
ONN-X96
Optical cross connect for 96 channels using DCM free network technology.
SON SON
SONF
Standalone Optical Node used for:
Passive optical multiplexing/demultiplexing optionally combined with transponder application.
Pure transponder application.
Long single span transmission by inter-working with RMH07, 1RU, and 2RU series from MPBC.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
129
OLR(Optical
Line Repeater)
OLR(Optical
Line Repeater)
ONN-T(Optical Network
Node Termination)
ONN-X (Remotely
reconfigurable PXC)
ONN-I(Optical Network
Node Interconnection)
ONN-R(Optical Network Node
Remotely reconfigurable)
ONN-S(Optical Network
Node Small OADM)
SON(Standalone Optical Node)
SON(Standalone Optical Node)
SON(Standalone Optical Node)
SURPASS hiT7300 Network Element Types
Depending from the NE type up to 40 shelves with up to 350 active cards (e.g. transponder, optical amplifier), can be supported
Fig. 120 SURPASS hiT7300 Network Element Types_1
Standalone Optical Node used for:Passive optical multiplexing/demultiplexing optionally combined with transponder application.Pure transponder application.Long single span transmission by inter-working with RMH07, 1RU, and 2RU series from MPBC.
SONSONF
SON
Optical interconnection node for realization of a PXC with up to 40 (80) channels. Used for amplification, dispersion compensation, and partial or full add/drop.
ONN-X (80 / 96)
Optical interconnection node for realization of Small OADM. Used for amplification, dispersion compensation, and partial add/drop within a link.
ONN-S
Tunable ROADM for 40 (80) channels. It has a limited add drop capacity of 8 ch @ EOL 40 or 16 ch @ EOL 80 channels.
ONN-RT (80)
Cost optimized ROADM for 2 degree ONN with EOL 40 channel capacity. Used for amplification, dispersion compensation, and partial or full add/drop.
ONN-R2
Optical interconnection node for realization of a FullAccess OADM or Reconfigurable OADM (ROADM) with up to 40 (80) channels. Used for amplification, dispersioncompensation, and partial or full add/drop.
ONN-R (80)
Optical interconnection node for realization of a FullAccess OADM or Flexible OADM with up to 40 (80) channels. Used for amplification, dispersion compensation, and full add/drop.
ONN-I (80)
Optical termination node for realization of a Terminal 1/2 OADM with up to 40 (80) channels. Used for amplification, dispersion compensation, and full add/drop within an optical path.
ONN-T (80)ONN
Optical Line Repeater Used for optical signal amplification with dispersion compensation.Terminates 2 spans.
n.a.OLR
DescriptionSubtypeNE
Fig. 121 SURPASS hiT7300 Network Element Types_2
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 130
3.1 Optical Line Repeater (OLR) Network Element The OLR is a DWDM NE which supports:
• The following card types:
– Controller cards
– Inline amplifier cards
– External pump cards
– Dispersion compensation module cards
• Raman amplification together with one line amplifier card.
• Two bidirectional OSC terminations within a single shelf.
• Power reduction to class 1M (APSD) for laser safety on line, with and without Raman amplification.
The OLR is used for amplification, channel power boost, power tilt adjustment, and dispersion compensation in a single-shelf realization, even when Raman pump cards are required.
The OLR is used as a repeater for optical DWDM signals in both 40-channel and 80-channel DWDM transmission systems. The OLR network element structure consists per transmission direction of an optical inline amplifier card with optional external pump card (PL-1), and optional Raman pump card (PRC-1) for maximum span reach. Dispersion compensation for an optical span is applied at the interstage access ports of the related inline amplifier, either as Dispersion Compensation Module (DCM) cards within the shelf, or as separate modules in managed Unidirectional Dispersion Compensation Module (UDCM) trays, depending on the specific fiber type and the required compensation value.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
131
Fig. 122 Block diagram OLR
CC
EP
DxxxxS
MF
PR
C
LA
LI
LA
LI
DxxxxS
MF
PL
PL
PR
C
Fig. 123 Example of OLR NE sub-rack equipping
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 132
3.2 Optical Network Node (ONN) The ONN is a multi-degree optical network node which terminates multiple Optical Multiplex Sections (OMS) by optical multiplexing/demultiplexing of individual optical channels/wavelengths. The number of OMS links terminated by an ONN determines the nodal degree of the ONN.
An ONN realizes a comprehensive family of optical DWDM network elements for implementing fixed Optical Terminal nodes as well as fixed or remotely reconfigurable Optical Add/Drop Multiplexers (OADM or ROADM) and Photonic Cross-Connects (PXC) for multi-degree nodes switching and aggregating traffic from multiple directions.
Filter Structure Filter Structure ONN Sub-type
Flexible Full Access
ONN Sub-type
Flexible Full Access
ONN-T 40 X X ONN-R 40/80 X
ONN-T 80 X ONN-X 40/80 X
ONN-I 40 X X ONN-S X
ONN-I 80 X ONN-R2 X
ONN-RT40 X ONN-RT80 X
In case of flexible filter structure the filter structures for the different EOL channel counts are flexible with respect to the channel upgrade sequence. The following Table shows the example of upgrade sequence chart. The actual task of wavelength planning and card selection is fully automated and performed by TransNet engineering and planning tool.
EOL Channel Count
12 ch. 20 ch. 32 ch. 40 ch.
Upgrade Chart
Filter Type Filter Type Filter Type Filter Type
1st F04MDU08 F04MDU08 F04MDUC08 F08SB+F04MDN06
2nd F04MDU06 F08SB+F04MDN06 F08SB+F04MDN06 F04MDN05
3rd F04MDU05 F04MDN05 F04MDN05 F16SBR+F04MDN08
4th F04MDN07 F16SBR+F04MDN07 F04MDN07
5th F04MDN04 F04MDN09 F04MDN09
6th F04MDN10 F04MDN10
7th F16SBB+F04MDN04 F16SBB+F04MDN04
8th F04MDN03 F04MDN03
9th F04MDN02
10th F04MDNC01
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
133
Optical Network Node (ONN) Optical Network Node (ONN)
Fig. 124 Optical Network Node (ONN)
Upgrade sequence chart (flexible filter structure ) Upgrade sequence chart (flexible filter structure )
Fig. 125 Upgrade sequence chart
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 134
3.2.1 Examples of Flexible filter structure
Flexible filter structure for EOL=12 The following figure displays the filter structure for EOL=12 with the upgrade path from the first channel (group) to the last channel (group). The three 4-channel sub-bands (Cxx) are located within the flat region of the optical amplifier band. The upgrade path allows any upgrade order for three 4-channel sub-bands.
Cx
F04MDN-1
λi λj λk λl
F04MDU-1
λi λj λk λl
Cy
F04MDU-1
λi λj λk λl
Cz
LAxB
DWDM Line
preamp
booster
LAxP
(C05, C06, C08)(C05, C06, C08)(C05, C06, C08)
1st channel group2nd channel group3rd channel group
ONN-T; Optical Terminal (12 Channels End-of-Life Capacity)ONN-T; Optical Terminal (12 Channels End-of-Life Capacity)
Fig. 126 Example of Flexible filter structure for EOL=12
Flexible filter structure for EOL=20 The following figure displays the basic filter structure for EOL=20 with the upgrade path from the first channel (group) to the last channel (group). The upgrade path allows any upgrade order for these sub-bands.
F08SB-1C01,C02,C03,C04
C07,C08,C09,C10
C05
C06
F04MDN-1
λi λj λk λl
F04MDN-1
λi λj λk λl
F04MDN-1
λi λj λk λl
F04MDN-1
λi λj λk λl
F04MDU-1
λi λj λk λl
LAxB
DWDM Line
preamp
booster
LAxP
(C07 or C08)
(C08 or C07)
(C04)
(C05)
(C06)
ONN-T; Optical Terminal (20 Channels End-of-Life Capacity)ONN-T; Optical Terminal (20 Channels End-of-Life Capacity)
Fig. 127 Example of Flexible filter structure for EOL=20
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
135
Flexible filter structure for EOL=32 The following figure displays the basic filter structure for EOL=32 with the upgrade path from the first channel (group) to the last channel (group). The upgrade path allows any upgrade order for these sub-bands.
F04MDN-1
λiλj λk
λl
F08SB-1
C01,C02,C03,C04
C07,C08,C09,C10
C05
C06
F16SB-1 (blue)
C01C02C03C04
F16SB-1 (red)
C07C08C09C10
F04MDN-1
λiλj λk λl
F04MDN-1
λiλj λk
λl F04MDN-1
λiλj λk
λl F04MDN-1
λiλj λk
λl
F04MDN-1
λiλj λk
λl
F04MDN-1
λiλj λk
λl LAxBDWDM
Line
preamp
booster
LAxP
(C03)
(C04 )
(C 07 or C 08
(C 08 or C 09
(C10)
(C05)
(C06)
F04MDU-1
λi λj λk λl
(C07 or C08 or C09)
ONN-T; Optical Terminal (32 Channels End-of-Life Capacity)
ONN-T; Optical Terminal (32 Channels End-of-Life Capacity)
Fig. 128 Example of Flexible filter structure for EOL=32
Flexible filter structure for EOL=40 The following figure displays the basic filter structure for EOL=40 with the upgrade path from the first channel (group) to the last channel (group). The upgrade path allows any upgrade order for these sub-bands. The F08SB-1 card with the red/blue band splitter is always required.
F04MDN-1
λi
λj
λk
λl
F08SB-1
C01,C02,C03,C04
C07,C08,C09,C10
C05
C06
F16SB-1 (blue)
C01
C02
C03
C04
F16SB-1 (red)
C07
C08
C09C10
F04MDN-1
λi
λj
λk
λl
F04MDN-1
λi
λj
λk
λl
F04MDN-1
λi
λj
λk
λl
F04MDN-1
λi
λj
λk
λl
F04MDN-1
λi
λj
λk
λl
F04MDN-1
λi
λj
λk
λl
F04MDN-1
λi
λj
λk
λl
F04MDN-1
λi
λj
λk
λl
F04MDN-1
λi
λj
λk
λl
LAxB
DWDM Line
preamp
booster
LAxP
(C06)
(C10)
(C05)
(C04)
ONN-T; Optical Terminal (40 Channels
End-of-Life Capacity)
ONN-T; Optical Terminal (40 Channels
End-of-Life Capacity)
Fig. 129 Example of Flexible filter structure for EOL=40
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 136
3.2.2 Optical Network Node - Terminal, (ONN-T)
The ONN-T is a DWDM NE which is used in Terminal 1/2 OADM architecture. It multiplexes and demultiplexes all channels. The basic ONN-T structure consists of transponder cards, filter cards, and optical line amplifier cards (with optional external pump card(s) and with optional Raman pump card for maximum span reach). Dispersion compensation for an optical span is applied at the interstage access ports of the related amplifier, either as DCM cards within the shelf, or as separate modules in managed UDCM trays, depending on the specific fiber type and the required compensation value.
Flexible ONN-T StructureFlexible ONN-T Structure
Optical Amplifier, DCM, optional cards
(optional)
(optional)
(optional) (optional)
DCM Pump
Booster
DCMPump
Ramanpump
MC
P4xx
OS
A
( optio
nal)
Pre-Amplifier
OpticalMUX/DMUX
VOA cards,or fixed atten.
flexible subbandstructure
Transponder/Muxponder
10G
2.5G
2.5G
40G
bidirectionalcards
Fig. 130 Flexible Optical Terminal ONN-T
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
137
Optical Amplifier, DCM, optional cards
(optional)
(optional)
(optional) (optional)
DCM Pump
Booster
DCMPump
Ramanpump
MC
P4
xx
OS
A
(op
tion
al )
Pre-Amplifier
OpticalMUX/DMUX
VOA cards,or fixed atten.
also possible as single VMUX card (F40V)
also possible as single VMUX card (F40V)
F40
F40
Transponder/Muxponder
10G
2.5G
2.5G
40G
unidirectionalcards
FullAccess ONN-T StructureFullAccess ONN-T Structure
Fig. 131 FullAccess Optical Terminal ONN-T
AWG structure
MUX/DMUX cards
F40(V)/O
F40(V)/S
F40(V)/O
F40(V)/S
F80
MD
I
Interleavercard
VOA cards or fixed attenuators
Transponder/Muxponder
10G
2.5G
2.5G
40G
combined VOA+MUX function on F40V cards
Optical Amplifier, DCM, optional cards
(optional)
(optional) (optional)DCM Pump
Booster
DCMPump
MC
P4xx
OS
A
(op
t iona
l)
Pre-Amplifier
(optional)
Ramanpump
combined VOA+MUX function on F40V cards
ONN-T 80 StructureONN-T 80 Structure
Fig. 132 ONN-T 80 structure
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 138
3.2.3 Optical Network Node - Interconnect (ONN-I)
The ONN-I is a DWDM NE which is used in Flexible or FullAccess OADM architecture. It is used for amplification, dispersion compensation, termination of links, and optical channel termination via transponders. The basic ONN-I structure consists of transponder cards (if channels termination is required), filter cards, and optical line amplifier cards (with optional external pump card(s) and with optional Raman pump card for maximum span reach). Dispersion compensation for an optical span is applied at the interstage access ports of the related amplifier, either as Dispersion Compensation Module (DCM) cards within the shelf, or as separate modules in managed UDCM trays depending on the specific fiber type and the required compensation value.
direction 1
Optical Amplifier, DCM, optional cards
(optional)
(optional) (optional)DCM Pump
Booster
DCMPump
MC
P4
xxO
SA
( option
al)
Pre-Amplifier
(optional)
Ramanpump
Optical Amplifier, DCM, optional cards
(optional)
(optional)(optional)DCMPump
Booster
DCM Pump
MC
P4
xxO
SA
(op
tiona
l)
Pre-Amplifier
(optional)
Ramanpump
VOA cards or fixed attenuators
OpticalMUX/DMUX
cards
flexible subbandstructure
OpticalMUX/DMUX
cards
flexible subbandstructure
pass-through
pass-through
dro
p
ad
d
add
dro
p
direction 2
Tra
ns
po
nde
r /M
ux
po
nd
er
10G
2.5
G
2.5
G
40G
VOA cards or fixed attenuators
bidirectionalcards
bidirectionalcards
ONN-I Flexible Structure; Nodal degree 2ONN-I Flexible Structure; Nodal degree 2
Fig. 133 Optical Network Node - Interconnect (ONN-I)
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
139
OpticalMUX/DMUX
cards
AWG structure
F40
F40
unid
i recio
nal
card
s
direction 1
Optical Amplifier, DCM, optional cards
(optional)
(optional) (optional)DCM Pump
Booster
DCMPump
MC
P4
xxO
SA
( option
al)
Pre-Amplifier
(optional)
Ramanpump
Optical Amplifier, DCM, optional cards
(optional)
(optional)(optional)DCMPump
Booster
DCM Pump
MC
P4
xxO
SA
(op
tiona
l)
Pre-Amplifier
(optional)
Ramanpump
VOA cards or fixed attenuators
pass-through
pass-through
dro
p
a dd
add
dro
p
direction 2
Tra
ns
po
nde
r /M
ux
po
nd
er
10G
2.5
G
2.5
G
40G
VOA cards or fixed attenuators
OpticalMUX/DMUX
cards
AWG structure
F40
F40 uni
dire
cio
nal
card
s
also possible as single VMUX
card F40V
also possible as single VMUX
card F40V
ONN-I FullAccess Structure; Nodal degree 2ONN-I FullAccess Structure; Nodal degree 2
Fig. 134 Optical Network Node - Interconnect (ONN-I)
VOA cards or fixed attenuators
direction 1
Optical Amplifier, DCM, optional cards
(optional)
DCMPump
Booster
DCM Pump
MC
P4 xxO
SA
(o pt ional)
Pre-Amplifier
(optional)
Ramanpump
(optional) (optional)
F80
MD
I
Interleavercard
AWG structure
MUX/DMUX cards
F40(V)/O
F40(V)/S
F40/O
F40/S
F80
MD
I
Interleavercard
VOA cards or fixed attenuators
pass-through
drop
add
a dd
drop
direction 2
Tran
spo
nder
/M
uxp
ond
er
10G
2.5G
2.5G
40G
combined VOA+MUX function on F40V cards
Optical Amplifier, DCM, optional cards
(optional)
(optional) (optional)DCM Pump
Booster
DCMPump
MC
P4xx
OS
A
(opti onal )
Pre-Amplifier
(optional)
Ramanpump
AWG structure
MUX/DMUX cards
F40/O
F40/S
F40(V)/O
F40(V)/S
pass-through
combined VOA+MUX function on F40V cards
direction 1
ONN-I FullAccess Structure, 80 Channels; Nodal degree 2ONN-I FullAccess Structure,
80 Channels; Nodal degree 2
Fig. 135 Optical Network Node - Interconnect (ONN-I)
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 140
3.2.4 Optical Network Node - Reconfigurable (ONN-R)
The ONN-R is a DWDM NE which is used in FullAccess OADM, or ROADM architectures by combining the functions of optical channel multiplexing/demultiplexing and optical channel (wavelengths) switching to a very compact solution of a (remotely) reconfigurable optical add/drop multiplexer with 100% access to all 40 optical channels on a DWDM line interface. The basic ONN-R structure consists of transponder cards (if channels termination is required), filter cards (F40MR-1 cards and F40-1 cards if add/drop of a single channel is required), optical line amplifier cards (with optional external pump card(s) and with optional Raman pump card for maximum span reach). Dispersion compensation for an optical span is applied at the interstage access ports of the related amplifier, either as DCM cards within the shelf, or as separate modules in managed UDCM trays depending on the specific fiber type and the required compensation value.
VOA cards or fixed attenuators
(not in case of F40V)
OpticalMUX/DMUX/ROADM
cards
Direction 1 Direction 2
pass-throughtraffic
F40(V)
...
...
local add
local add
local drop
λi
F40MR
λi
F40MR
local drop
Optical Amplifier, DCM, optional cards
(optional)
DCM Pump
Booster
DCMPump
MC
P4xx
OSA
(opt
iona
l)
Pre-Amplifier
(optional)
Ramanpump
(optional) (optional)
Optical Amplifier, DCM, optional cards
(optional)
(optional)(optional)DCMPump
Booster
DCM Pump
MC
P4x
xO
SA
(opt
iona
l)
Pre-Amplifier
(optional)
Ramanpump
F40(V)
Tran
spo
nder
/M
uxp
ond
er
10G
2.5
G
2.5
G
40G
pass-throughtraffic
ONN-R; Nodal degree 2ONN-R; Nodal degree 2
Fig. 136
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
141
OpticalMUX/DMUX/ROADM
cards
Direction 1Direction 2
local drop
...
F40
...
...
local add
local add
local drop
local add
local drop
λi
F40MR
λi
F40MR
Dir
ectio
n3
Optical Amplifier, DCM, optional cards
(optional)
(optional)(optional)DCMPump
Booster
DCM Pump
MC
P4x
xO
SA
(opt
iona
l)
Pre-Amplifier
(optional)
Ramanpump
Optical Amplifier, DCM, optional cards
(optional)
DCM Pump
Booster
DCMPump
MC
P4x
xO
SA
(opt
iona
l)
Pre-Amplifier
(optional)
Ramanpump
(optional) (optional)
Opt
ical
Am
plif
ier,
DC
M,op
tiona
lcar
ds
(optio
nal)
(op t
iona
l)(o
ptio
nal)
DC
MP
ump
Boos
t er
DC
MP
ump
MCP4xxOSA
(optional)
Pr e
-Am
plifi
er
(opt
iona
l)
Ram
anpu m
p
pass-throughtraffic
pass-throughtraffic
F40(V)
F40(V)
VOA cards /fixed atten.(not in case
of F40V)
...
F40(V)
ONN-R; Nodal degree 3ONN-R; Nodal degree 3
Fig. 137
Optical MUX /DMUX andWSS cards
Direction 2
pass-throughtraffic
local drop
pass-throughtraffic
local add
local add local drop
Direction 1
Optical Amplifier, DCM, optional cards
(optional)
(optional) (optional)DCM Pump
Booster
DCMPump
MC
P4
xxO
SA
Pre-Amplifier
(optional)
Ramanpump
Direction 1
Optical Amplifier, DCM, optional cards
(optional)
DCMPump
Booster
DCM Pump
MC
P4
xxO
SA
Pre-Amplifier
(optional)
Ramanpump
(optional) (optional)
F8
0DC
I
F06MR 80
WSS
F4
0V
/OF4
0V/S
F40
/O
F40/S
F80
DC
I
F06MR80
WSS
F4
0V
/O
F4
0V
/S
F4
0/O
F40
/S
Tra
ns
po
nd
er/
Mu
xpo
nd
er
10
G
2.5
G
2.5
G
40
G
ONN-R 80; Nodal degree 2ONN-R 80; Nodal degree 2
Fig. 138
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 142
3.2.5 Optical Network Node – Small, ONN-S
The ONN-S is a 40-channel DWDM NE in Small OADM architecture. It is used for amplification and link start-up of add/drop-channels within an optical path. The ONN-S is cost-optimized for network applications with only a small number of add/drop-channels at intermediate sites, where up to 8 channels out of two 4-channel sub-bands can be added/dropped from each of the 2 line directions.
The ONN-S only uses a partial optical multiplexing/demultiplexing scheme for the channels to be locally accessed, while all other optical channels are automatically passed-through as express traffic.
Each line interface of the ONN-S structure consists of an optical booster and pre-amplifier, dispersion compensation cards, and optional external pump card(s) and Raman pump card for the booster. The ONN-S has a maximum add/drop capacity of 8 channels. Channels that are dropped at an ONN-S are terminated at the client equipment.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
143
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Optical MUX /DMUX cards
Direction 1 Direction 2
localadd/drop
Optical Amplifier , DCM , optional cards
(optional)
(optional) (optional)DCM Pump
Booster
DCMPump
Pre -Amplifier
(optional)
Ramanpump
Optical Amplifier , DCM , optional cards
(optional)
(optional )(optional )DCMPump
Booster
DCM Pump
Pre -Amplifier
(optional)
Ramanpump
Op
tica
lA
tte
nu
a to
rc
ard
s
localadd/drop
2.5
G
2.5
G
10
G
10 G
Tra
ns
pon
der
card
s
up to 2x 4 channels add /dropto/from direction 1
up to 2x 4 channels add /dropto/ from direction 2
subband x subband xsubband y subband y
Optical Network Node–Small, ONN-SOptical Network Node–Small, ONN-S
Fig. 139 Optical Network Node – Small, ONN-S
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 144
3.2.6 Optical Network Node - ONN-R2
ONN-R2 is a ROADM with F02MR-1 nodal degree 2.
The ONN-R2 is a 40-channel DWDM NE which is used in a ROADM architecture to provide optical channel multiplexing/demultiplexing and optical channel (wavelengths) switching in a very compact solution of a remotely reconfigurable optical add/drop multiplexer with 100% access to all 40 optical channels on a DWDM line interface.
When compared with the ONN-R, the ONN-R2 is restricted to nodal degree 2 applications and his basic structure consists of transponder cards (if channels termination is required), filter cards (two F02MR-1 and four F40(V)-1 or F04MDU-1 cards for local add/drop), optical line amplifier cards (with optional external pump card(s) (PL-1) and with optional Raman pump card (PRC-1) for maximum span reach). Dispersion compensation for an optical span is applied at the interstage access ports of the related amplifier, either as DCM cards within the shelf, or as separate modules in managed UDCM trays depending on the specific fiber type and the required compensation value The ONN-R2 is a more cost optimized alternative to the ONN-R in applications that do not require a higher nodal degree or low add-loss.
Any OTN using ONN-R2 NEs provides a dynamic wavelength provisioning across the DWDM network, therefore, allowing a modification of the customer traffic demands without manual equipment installation at intermediate locations by local field service personnel (OPEX reduction).
ONN-R2 StructureONN-R2 Structure
Fig. 140 ONN-R2 Structure
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
145
Fig. 141Block diagram ONN-R2
Direction 1
Fig. 142Block diagram (Direction 1)
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 146
3.2.7 Optical Network Node - ONN-RT
Optical Network Node - ONN-RT is an Colorless ROADM w/F09MDRT-1/x nodal degree 2.
The ONN-RT is a 40-channel DWDM NE which is used in a Metro tunable ROADM architecture by combining the functions of optical channel multiplexing/demultiplexing and optical channel (wavelengths) switching into a very compact solution of a (remotely) reconfigurable optical add/drop multiplexer with 100% access to all 40 optical channels on a DWDM line interface.
The basic 40-channel ONN-RT structure consists of transponder cards (if channels termination is required), F09MDRT-1/S filter cards, and optical line amplifier cards (with optional external pump card(s) (PL-1) and with optional Raman pump card (PRC-1) for maximum span reach). Dispersion compensation for an optical span is applied at the interstage access ports of the related amplifier, either as DCM cards within the shelf, or as separate modules in managed UDCM trays depending on the specific fiber type and the required compensation value.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
147
ONN-RT StructureONN-RT Structure
Fig. 143
Fig. 144
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 148
3.2.8 Optical Network Node - Reconfigurable/Tunable (80 channels) – ONN-RT(80)
The ONN-RT80 is a 80-channel DWDM NE which is used in a Metro tunable ROADM architecture by combining the functions of optical channel multiplexing/demultiplexing and optical channel (wavelengths) switching into a very compact solution of a (remotely) reconfigurable optical add/drop multiplexer with 100% access to all 40 optical channels on a DWDM line interface.
The basic 80-channel ONN-RT structure consists of transponder cards (if channels termination is required), filter cards (two F09MDRT-1/S, two F09MDRT-1/O, and two F80MDI), and optical line amplifier cards (with optional external pump card(s) (PL-1) and with optional Raman pump card (PRC-1) for maximum span reach). Dispersion compensation for an optical span is applied at the interstage access ports of the related amplifier, either as DCM cards within the shelf, or as separate modules in managed UDCM trays depending on the specific fiber type and the required compensation value.
As the ONN-RT the ONN-RT80 supports 16 colorless add/drop channels per direction.
Each add/drop wavelength is tunable and remotely configurable. Any OTN using ONN-RT80 NEs provides a dynamic wavelength provisioning across the DWDM network, therefore, allowing a modification of the customer traffic demands without manual equipment installation at intermediate locations by local field service personnel (OPEX reduction).
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
149
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ONN-RT(80) StructureONN-RT(80) Structure
Fig. 145 ONN-RT(80) Structure
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 150
3.2.9 Optical Network Node - Cross-Connect (ONN-X)
The ONN-X is an advanced 40-channel DWDM NE which is used in PXC architecture. The basic 40-channel ONN-R structure consists of transponder cards (if channels termination is required) and an optical channel switching matrix filter card (F80MR-1). The F80MR-1 card, in the transmitting direction of the DWDM line, realizes a reconfigurable optical switch matrix with low insertion loss for each individual wavelength to select per wavelength between 40 input optical channels received from any other DWDM line port and 40 multiplexed wavelengths of local incoming channels. In the receiving direction of the DWDM line, a passive optical splitter forwards the received line signal to both pass through traffic and drop traffic output ports. Drop traffic is then demultiplexed into individual channels by a F40(V)-1 filter demultiplexer card. For the counter-directional line traffic, another combination of F08MR-1 and F40(V)-1 cards perform the analog channel switching and demultiplexing functions. Pass-through traffic between 2 line directions is forwarded by direct DWDM interconnections between the corresponding F08MR-1 cards.
In each line section the ONN-X structure also includes optical amplifier cards (with optional external pump card(s) (PL-1) and with optional Raman pump card (PRC-1) for maximum span reach). Dispersion compensation for an optical span is applied at the interstage access ports of the related amplifier, either as DCM cards within the shelf, or as separate modules in managed UDCM trays depending on the specific fiber type and the required compensation value.
ONN-X; Nodal degree 2ONN-X; Nodal degree 2
Optical MUX/DMUX and WSS cards
Direction 1 Direction 2
pass-throughtraffic
local dropOptical Amplifiers, DCM, optional cards
(optional)
(optional)(optional)DCMPump
Booster
DCM Pump
MC
P4x
xO
SA
Pre-Amplifier
(optional)
Ramanpump
Tra
nsp
ond
e r/
Mu x
pon
der
10G
2.5G
2.5G
40G
pass-throughtraffic
F40V
...
F40
...
local add
...
F40V
F40
...
Optical Amplifiers, DCM, optional cards
(optional)
DCM Pump
Booster
DCMPump
MC
P4x
xO
SA
Pre-Amplifier
(optional)
Ramanpump
(optional) (optional)
local drop local add
F08MR1:7
WSS
F08MR
1:7
WSS
Fig. 146
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
151
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.9.1 Optical Network Node - Cross-Connect - PXC up to nodal degree 8
Fig. 147 ONN-X; Nodal up to degree 8
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 152
3.2.10 Optical Network Node - Cross-Connect 80 channels – ONN-X80
The ONN-X80 is an advanced 80-channel DWDM NE which is used in a PXC architecture.
The basic 80-channel ONN-X80 structure consists of transponder cards (if channels termination is required), F06MR80-1 and F06DR80-1 MEMS-WSS filter cards for optical channel switching in multiplexing (transmitting) and demultiplexing (receiving) directions at each line interface, respectively, therefore forming a double-WSS structure.
The traffic to be locally dropped is divided by the WSS of the corresponding F06DR80- 1 filter card into 2 groups of 40 channels with 100GHz spacing using standard frequency grid and offset frequency grid, respectively. Each 40-channel drop group is amplified by a low-cost LASB-1 amplifier before being demultiplexed into individual drop-channels by the F40-1 demultiplexer filter card.
The traffic to be locally added to a DWDM line is first multiplexed into 2 groups of 40 channels with 100GHz spacing using standard frequency grid and offset frequency grid by the respective F40-1 multiplexer filter card. Each 40-channel add group is then aggregated by the WSS of the corresponding F06MR80-1 card, which also performs optical channel switching between local add channels and pass-through channels from any other DWDM line interface(s) of other direction(s).
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
153
F40
/O
F40
/S
F06MR80
WSS
F06DR80
WSS
F40
/O
F40
/S
LA
SB
toM
CP 4
LA
SBto
MC
P4
pass-throughtraffic
local drop
pass-throughtraffic
local add
local add local drop
1
Optical Amplifier, DCM, optional cards
(optional)
(optional) (optional)DCM Pump
Booster
DCMPump
MC
P4
xxO
SA
Pre-Amplifier
(optional)
Ramanpump
Direction 1
Optical Amplifier, DCM, optional cards
(optional)
DCMPump
Booster
DCM Pump
MC
P4 xx
OS
A
Pre-Amplifier
(optional)
Ramanpump
(optional) (optional)
Tra
nsp
onde
r/M
ux
po
nd
er
10G
2.5
G
2.5
G
40G
F40
/O
F4
0/S
F06MR80
WSS
F06DR 80
WSS
F40
/O
F40
/S
LA
SB
toM
CP
4 LA
SB
toM
CP
4
Direction 2 Direction 1
ONN-X 80; Nodal degree 2ONN-X 80; Nodal degree 2
Fig. 148
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 154
3.2.11 Optical Network Node - Cross-Connect 96 channels – ONN-X96
The ONN-X96 is an advanced 96-channel DWDM NE which is used in a PXC architecture with DCM-free transmission. The basic ONN-X96 structure consists of transponder cards (if channels termination is required) and F09MDR96-1 bidirectional tunable WSS filter card for optical channel switching in multiplexing (transmitting) and demultiplexing (receiving) directions at each line interface, respectively.
The ONN-X96 supports two add/drop structures, directional fixed frequency add/drop supported by F48MDP-1 cards and colorless and directionless add/drop supported by F09MDR96-1 cards and O09CC-1 for aggregation. A mixture of both add/drop structures is supported, see an example in figure.
The ONN-X96 supports up to 8 nodal degrees plus two colorless and directionless structures. Additional colorless and directionless structures are possible, to a maximum of 5.
For each additional structures the maximum nodal degree is reduced by one. For example, with 4 colorless and directionless structures is possible to have up to 6 nodal degrees.
For each line section, the ONN-X96 structure includes optical amplifier cards optimized for DCM-free networks (LABPC-1, LABBC-1), optional Raman pump card (PRC-2) for maximum span reach, optional channel power monitor card (MCP4-2) for monitoring of the optical channel power levels and optional transient suppression for C-band card (OTSC-1) for transient protection. When OTSC card is used the system is limited to 80 traffic channels.
Directional fixed frequency The directional fixed frequency structure is the most simple and cost effective technology to add/drop channels. Each port of the add/drop structure supports only one specific wavelength, each add/drop structure supports only one specific fiber degree and within the fiber degree, only one direction. This is ideally suited for static and directional traffic patterns.
The traffic to be locally dropped is divided by the F09MDR96-1 filter card into 2 groups of 48 channels with 50GHz spacing using standard frequency grid and offset frequency grid.
The traffic to be locally added to a DWDM line is first multiplexed into 2 groups of 48 channels with 50 GHz spacing using standard frequency grid and offset frequency grid by the respective F48MDP-1 multiplexer filter card. Each 48-channel add group is then aggregated in the F09MDR96-1 card by one of the WSS, which also performs optical channel switching between local add channels and pass-through channels from any other DWDM line interface(s) of other direction(s).
Pass-through traffic between any line direction is forwarded by direct DWDM interconnections between F09MDR96-1 filter cards.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
155
Colorless and directionless The colorless and directionless is a flexible technology to add/drop channels. Each port of the add/drop structure can access any wavelength from any direction of any degree within a node. It is therefore ideally suited for highly flexible traffic patterns.
The add/drop structure consists of WSS based switches (F09MDR96-1 used with the double WSS switching matrix resulting in reduced complexity) and splitters/ combiners (O09CC-1).
Logically it is divided into a directionless layer and a colorless layer. The directionless layer consists of one F09MDR96-1 switch, two LABxC-1 amplifiers and one splitter/combiner card (O09CC-1). Each port of the F09MDR96-1 can be connected to any WSS or splitter used in the switching matrix, allowing it to access all degrees.
The colorless layer consists of up to 9 F09MDR96-1 cards, each one connected to one port of the directionless layer. It is able to drop 9 different channels each, leading to a maximum of 81 tunable ports which can be freely chosen from the overall 96 available channels. F09MDR96-1 cards can be added in increments when demand increases without traffic impact. If more than 81 channels need to be dropped (colorless or two or more identical wavelengths need to be dropped), additional add/drop structures can be
added.
ONN-X96
Fig. 149
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 156
3.3 SON – Standalone Optical Node The SON network element is a derivative of the ONN for use as a stand-alone NE for the following applications:
3.3.1 Transponder NE
SON NE can be used as Pure Transponder NE as a feeder system for:
• hiT7500 DWDM system;
• any 3rd party DWDM system.
It provides the capability to use any hiT7300 transponder card, as a feeder to the optical channels of a DWDM system, thereby enabling the benefits of the hiT7300 transponders cards for alternative applications. The SON also supports optical channel protection. Using the tunable transponder card types of hiT7300 also compliance to a 50 GHz DWDM grid is achieved.
I04
T2
G5
I04
T2
G5
I04
T2
G5
I01T
10G
CC
EP
I01T
10G
I01T
10G
I01T
10G
I01T
10G
I01T
10G
I04T
2G5
I04T
2G5
I04T
2G5
I04T
2G5
I04T
2G5 Pure Transponder
NE as a feeder system for:
Pure Transponder NE as a feeder
system for:
hiT7500 DWDM system
Any 3rd party DWDM system
SON – Standalone Optical NodeSON – Standalone Optical Node
Fig. 150 hiT7300 SON as a Pure Transponder NE
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
157
3.3.2 Pure Passive Terminal or OADM (amplifier-less)
hiT7300 SON NE can be used as a simple low-cost DWDM system with up to 40 optical channels for short reach applications in metropolitan areas. It provides the capability to use the hiT7300 transponder and optical multiplexer/de-multiplexer cards without any optical amplifier cards. Also optical network configurations consisting of a linear chain of passive optical terminals with intermediate passive OADM can be build by SON NE's.
The multiplexing structure for a passive Terminal/OADM can be realized either by flexible filter structure depending on the required number of channels, or by the F40-1 filter cards providing access to all 40 channels already for first installation. Any flexible filter structure is supported which consists of a cascade of F04MDU filters cards optionally terminated by an F04MDN, which allows incremental upgrading in steps of 4-channel groups; alternatively the F08SB filter card as red/blue splitter can be used providing the advantage of lower insertion loss with higher number of channels.
Fig. 151 Example of Pure Passive Terminal and OADM configuration
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 158
Simple point-to-point Applications For simple point-to-point applications, a passive SON/SONF terminal allows the following distances over a G.652 fiber with the SURPASS hiT 7300 transponder cards:
• Up to 60 km for 40 optical 2.5 Gbit/s channels (70 km with an F40(V)-1 filter card).
• Up to 100 km for 28 optical 2.5 Gbit/s channels.
• Up to 18 km for 12 optical 10 Gbit/s channels.
• Up to 25 km for 8 optical 10 Gbit/s channels.
The exact reach depends on the number of multiplexed channels due to optical filters insertion loss. The reach has to be calculated according to the network application.
SON(passive Terminal )
OpticalMUX/DMUX
cards
2.5G
2.5G
10G
Transponder cards
OpticalMUX/DMUX
cards
2.5G
2.5G
10G
Transponder cards
SON(passive Terminal )
For simple point-to-point applications, SON NE’s allows the following distances over a G.652 fiber:
• Up to 60 km for 40 optical 2.5 Gbit/s channels (70 km with an F40(V)-1 filter card).• Up to 100 km for 28 optical 2.5 Gbit/s channels.• Up to 18 km for 12 optical 10 Gbit/s channels.• Up to 25 km for 8 optical 10 Gbit/s channels.
Fig. 152 Simple point-to-point Applications
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
159
3.3.3 Long single span applications
The long single span transmission can be achieved by:
• Interworking of SON and RMH07/1RU/2RU series equipment from MPBC for fiber spans using SSMF or PSCF.
• Using the SURPASS hiT 7300 LASBC-1 and LAMPC-1line amplifiers within SON. Interworking with the MPBC RMH07, 1RU, and 2RU amplification systems provide full support for submarine applications, with a maximum of 80 optical channels over the same fiber. Only point-to-point architectures without optical regenerator sites are supported.
Different configurations with different End of Life (EOL) channel counts are released.
The SON also provides a summary alarm supervision function for the connected MPBC RMH07, 1RU, and 2RU shelf/shelves via its external TIF contacts, so that in case of an alarm of the MPBC RMH07, 1RU, and 2RU amplification system the SON reports a corresponding alarm to the TNMS system indicating the affected services.
TIP For detailed information about the RMH07, 1RU, and 2RU series, please refer to the MPBC RMH07, 1RU, and 2RU series customer documentation.
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 160
Fig. 153 Long single span applications
Fig. 154 Maximum EOL channel count MPBC equipment
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
161
4 CWDM support
hiT 7300CWDM Support
!
Fig. 155 CWDM Support Types
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 162
The CWDM sub-system allows a very simple and low cost implementation of a passive (no amplification required) optical multiplexing system which can be used for data collection and aggregation of multiple client data from different remote locations within enterprise or small metropolitan networks.
The CWDM sub-system can be applied as a feeder system for a SURPASS hiT7300 NE or can simply be used as a standalone system for interconnection between first mile access equipment and second mile aggregation switches.
The following table lists all the CWDM frequencies supported by the CWDM sub-system:
Wavelengths (nm) Channel # Subband Comments
1271 17 --
1291 18 --
introduced in R4.3; channel deployed last due to higher attenuation
1311 9 B
1331 10 B
1351 11 B
1371 12 B
1391 13 D
1411 14 D
1431 15 D
1451 16 D
introduced in R4.3
1471 1 E
1491 2 E
1511 3 C
1531 4 C
1551 5 C
1571 6 C
1591 7 E
1611 8 E
introduced in R4.2
The CWDM sub-system main features are:
• Support of 18 wavelengths from CWDM grid (according to ITU-T G.694.2) with CWDM interfaces (according to ITU-T G.695).
• Support of 40 DWDM wavelengths and 14 CWDM wavelengths on the same fiber as pure passive system.
• Independent from SURPASS hiT7300 shelf.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
163
• Mechanical integration either by cascadable CWDM add/drop patch-cord connectors, or by cascadable CWDM filter modules plugged into 1 HU filter pack shelves.
• Compatible with ANSI, hiT7300 ETSI and standard ETSI racks.
• Compliant with Telcordia GR-1209 and GR-1221 for central office conditions.
Supported CWDM frequenciesSupported CWDM frequencies
Fig. 156 Supported CWDM frequencies
Supported CWDM frequenciesSupported CWDM frequencies
Fig. 157 Supported CWDM frequencies
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 164
4.1 Passive CWDM Filter Pack Solutions The following pluggable passive CWDM filter modules are available for filter-pack shelves:
• bidirectional single-channel CWDM add/drop modules FC01MDUP-1/n (n=1..8) with upgrade port the mechanical height of this module is 1/2 HU, up to 4 such modules can be plugged into a filter-pack shelf
• bidirectional 4-channel CWDM add/drop module FC04MDUP-1/E for the edge CWDM channels (i.e. channels 1,2,7,8) with in-service upgrade port for the center CWDM channels or in-service future (R4.2) upgrade with DWDM channels height of this module is 1 HU, up to 2 such modules can be plugged into a filter-pack shelf
• bidirectional 4-channel CWDM add/drop module FC04MDP-1/C for the center CWDM channels (i.e. channels 3,4,5,6) the mechanical height of this module is 1 HU, up to 2 such modules can be plugged into a filter-pack shelf
• bidirectional grey-channel (1310nm) band splitter module FC01MDUP-1/0 with upgrade port the mechanical height of this module is 1/2 HU
For internal use
1-ch module structure
upgradeable non upgradeable
FC01MDUP-1/n
Module view
FC01 (patch-cord)
Add/drop port
Express port
Common port
Fig. 158 1ch filter modules
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
165
For internal use
4-ch module structure
FC04MDUP-1/E FC04MDP-1/C
Module view:
Fig. 159 4ch filter modules
For internal use
List of supported filters
bidirectional grey-channel (1310nm) band splitter module
FC01MDUP-1/0
bidirectional 4-channel CWDM add/drop module for the center CWDM channels (i.e. 3,4,5,6
FC04MDP-1/C
bidirectional 4-channel CWDM add/drop module for the edge CWDM channels (i.e. 1,2,7,8)
FC04MDUP-1/E
bidirectional single-channel CWDM add/drop
FC01MDUP-1/n (n=1..8)
Single channel filter for 1291nm
FC01MDUP-1/18
Single channel filter for 1271nm
FC01MDUP-1/17
4 channel filter with upgrade port for 1311/1331/1371/1391nm
FC04MDUP-1/B
4 channel filter with upgrade port for 1351/1411/1431/1451nm
FC04MDUP-1/D
Birdirectional CWDM sub-band filter, separator wavelength 1461nm, separating ch 1..8 from 9..18
FC02SBP-1
hiT DWDM filters are supported in cards that reside within the hiT 7300 shelf types and hiT 7300 passive DWDM and CWDM filter modules are supported within a separate shelf.
Fig. 160 CWDM supported filter modules
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 166
4.2 CWDM Filter Architecture For local access to only a small number (1..3) of CWDM channels, a cascade of single channel filters FC01MDUP-1/n can be used. For access to 4 and up to 8 (9) CWDM channels (optionally including the grey channel) the 4-channel CWDM multiplexer cascade can be used leading to most compact realization and minimum insertion loss. In-service channel upgrades can easily be deployed using the upgrade ports (UP) of the multiplexer modules for cascading of additional modules.
Similarly, add/drop multiplexing schemes can be realized for a small number of channels by cascading of single-channel multiplexing modules FC01MDUP-1/n and using the upgrade port (UP) either for an additional multiplexer stage or for through-passing of traffic between 2 directions of a CWDM transmission line.
For internal use
CWDM Filter Architecture for 18 channels
Fig. 161 18 channel CWDM filter architecture
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
167
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For internal use
Combination with 14ch CWDM with 40ch DWDM
-DWDM: 100 GHz grid
Fig. 162 14 channel CWDM + 40 channel DWDM filter architecture
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 168
4.3 CWDM Topologies With CWDM, linear point-to-point, point-to-multipoint (collector) and ring topologies are supported as shown in the following overview example.
For internal use
CWDM topologies
Ring, linear extension (stub), and linear collector topologies
DSLAM
DSLAMs
DSLAM
CWDM ringLinear CWDM extension
Linear CWDM collector
FC01MDUP-1/1Single Channelbidi CWDM filter
Channel #1
FC01MDUP-1/2Single Channelbidi CWDM filter
Channel #2
FC01MDUP-1/3Single Channelbidi CWDM filter
Channel #3
FC04MDUP-1/E4-Channel
bidi CWDM filters
Fig. 163 Supported CWDM topologies
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
169
5 Hardware design
hiT 7300Hardware
!
Fig. 164 Hardware
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 170
5.1 hiT7300 racks The SURPASS hiT7300 rack is designed to meet the demands for environmental compatible product design and the customer demands for minimum space consumption. This requires a mechanical concept with respect to cabling, screening attenuation and power dissipation.
The rack is operated by an AC/DC station converter and a battery 48/60V (ETSI/ANSI), positive grounded. Voltage range is between -40.5 V DC to -75 V DC (nominal voltage -48/-60 V DC).
The racks can be installed individually or in combination. Independent network elements can also be fitted into a rack. The rack is installed and attached below a planar cable shelf or to the wall depending on the local circumstances. To allow this, the rack has a height-adjustable adapter. The lower part of the rack is fixed to the bottom rails with two pins or alternatively screwed to the floor. Height-adjustable feet can compensate for unevenness in the floor of up to 25 mm.
The bottom of the rack is open so as to let in fresh air; likewise the top of the rack is open as an air outlet and cable feed-through.
All electrical lines (connection lines for the telecommunications center, cabling between the sub racks and the rack terminal panel) as well as the FO lines will be routed using the upright rails of the rack and are secured with cable ties.
Rack, sub-rack and modules are grounded by multiple mechanical and electrical connections to the planar shelf (protection earth).
300 mm
Cables
600 mm
2200 mm
PDP
Height-adjustable feet
Power Distribution Panel
305 mm
Cables
660 mm
2134 mm
ETSIRack
ANSIRack
PDP
LVD
Low Voltage Disconnect device
Fig. 165 Design of the SURPASS hiT7300 racks
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
171
5.1.1 hiT7300 Rack Layout
Each rack contains a power distribution panel (PDP) typically mounted near the top. The fuse panel contains sufficient number of fuses (or circuit breakers) to protect all the dual redundant power feeds that are connected to each shelf in the rack. Each rack may be also equipped with an optional Low Voltage Disconnect device (LVD) mounted above the PDP. The LVD monitors the DC voltage feeds supplied to the rack from the battery distribution bay, and will automatically block a power feed whose voltage drops below the lowest allowed limit. Thus, the LVD prevents low voltage from reaching the shelves in the rack. When the voltage feed recovers to the proper operating range, the LVD will automatically unblock it.
Beside the PDP and optionally LVD on top of the rack, up to three single row sub-racks can be mounted in one rack.
For internal use
Flexible Mechanical Concept
Shelf type
• 510 (H) x 500 (W) x 280 (D) mm³ (ANSI and ETSI racks)
• 15 universal slots for transponders, filters, amplifiers, dispersion compensating modules, protection cards, …
• Each shelf may contain any arbitrary mix of cards– no unused, empty rack space
• Shelf also as 19” variant with 13 universal slots
High scalability
• Every node (terminal, repeater, OADM) can start with a single shelf
• Up to three shelves per rack including cable management
• Up to 32 10G-channels (transponders and optical cards) ina single rack
• Network termination unit for OTU1/2, 10GE
Cost optimization for any configuration size
Fig. 166 hiT7300 Rack Layout
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 172
5.2 hiT7300 Sub-racks
5.2.1 Standard shelf
The shelves are available as single row shelf in various versions for different applications (ETSI standard, ETSI special, ANSI). All types of shelf are realized as one mechanical concept with plug-in technique and front access of the cards and the fiber connections.
Each shelf consists of:
• Card slots for installing 16 cards (15 standard slots, 1 controller slot).
• Fiber guides to avoid accidental crimping or squeezing of the optical fibers.
• Fan unit with 4 fan packs to cool the shelf’s electronic equipment.
• Air filter to protect the electronics and optics from dust and other contaminants.
• Edge protection devices on both sides to avoid fiber bending.
• Shelf connector panel with connectors for power supply, grounding and laser power shutdown network.
• Connector for the grounding of wrist straps.
Shelf View
The 12 HU standard shelf
Fan Tray
Dedicated fiber routing space for easy card
equipping and fan tray exchange
Front access only shelf,
wall mounting possible
15 standard traffic cards multiplexer, transponder
etc.
One slot for standard hiT 7300 controller
Extra slack fiber storage
One universal shelf size;two size of brackets to adapt for ETSI and ANSI shelf width
Fig. 167 hiT7300 Sub-racks
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
173
In order to achieve a minimum rack spacing by allowing the outlets of the optical cables to be in front of the rack beams, it is recommended to use the available special ETSI rack for assembling SURPASS hiT7300 shelves.
SURPASS hiT7300 shelves can also be assembled within standard ETSI racks. However, in case of mounting a hiT7300 shelf into a standard ETSI rack, the usable cabling space in front of the rack beams is rather small which leads to cabling limitations for typical ONN applications. Therefore, it is advised to apply standard ETSI rack assembling only in case of OLR applications.
TIP SURPASS hiT7300 sub-rack can be equipped with the front cover to protect optical cabling against damage (optional, not applicable in combination with rack front door).
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 174
hiT7300 Special ETSI ShelfStandard ETSI Shelf
Fig. 168 Standard ETSI and Special ETSI shelves
SRS-1 shelf SRS-2 shelf
• ETSI or ANSI shelf• 16 slots available• 1x fan unit CFS1 or CFS2
• ETSI or ANSI shelf• 16 slots available• 4x fan unit CFS3 or CFS4
Fig. 169 hiT7300 shelf types
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
175
5.2.2 Flatpack shelf
The SURPASS hiT 7300 also provides a flatpack shelf for small NE installations that require only a few cards, (e.g., remote passive network termination using SONF with one or two transponder cards only).
The flatpack shelf can be mounted into ETSI, ANSI and 19” racks, the material of the flatpack shelf frame is stainless steel.
TIP The flatpack shelf solution can only be implemented in SONF NE's.
CPE flatpack
The flatpack shelf shares cards with the full size shelf in an only5 HU/225mm high shelf (vs 12 HU/517mm of full size shelf)
Fan Tray
Dedicated fiber routing avoids trouble with fan
tray exchange
19/21 inch, wall mounting, desktop
Front access only
Five standard traffic cards multiplexer, transponder etc.
Slot on top alternatively for 110/220V power
supply (for AC operation)
Slot for standard hiT 7300 controller; extension shelf
supported
Fig. 170
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 176
5.2.3 19" shelf
The SURPASS hiT 7300 also provides a 19 inch shelf for installations in computer racks that require a high amount of cards.
The 19" shelf can be mounted into 19” racks, the material of the 19" shelf frame is stainless steel.
SURPASS hiT7300 19“ shelf
Fig. 171 19" shelf
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
177
5.2.4 DCM Shelf
The DCM shelf is needed in cases where external dispersion compensation modules are required for dispersion compensation. The DCM's are inserted in drawers which can be pulled out of the shelf. The drawers are fixed via telescope rails to the frame of the DCM shelf. The drawers are provided with locks in order to prevent unintentional opening. The drawers can be pulled out without using any special tool.
One DCM shelf is capable for plugging of 4 DCMs of height 1HU or 2 DCMs of height 2HU, respectively.
Dispersion Compensation Module ShelfDispersion Compensation Module Shelf
Fig. 172
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 178
5.2.5 Shelf fan unit and air filter
The shelf fan unit and air filter are mounted in the middle of the shelf, between the fiber routing guides and the connector panel.
Fan unit: Each shelf is equipped with a fan unit that provides cooling airflow for the cards. The fan unit is held securely in place by hand-operated latches. The operating status of the four individual fans inside the unit is monitored. Detection of a fault condition will raise the appropriate system alarm and light the LED on the front of the fan unit.
Air filter: The fan unit contains a one-piece replaceable air filter element to protect the shelf from ingesting environmental dust or other airborne contaminants. Air filter replacement must be treated as a periodic maintenance procedure to ensure that the fans are able to sustain optimum shelf operating temperature.
WARNING An excessively dirty air filter will reduce cooling airflow.
WARNING Always provide adequate air cooling. A populated shelf must not be operated without the fan unit for more than 10 minutes.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
179
• One fan drawer per shelf with a slide-in fan unit
• The fan unit is equipped with four fans and an air filter
• Front access: the fan unit can be extracted out of the subrack without using special tools
• The fans will stop within a few seconds after removing the fan unit from the drawer
• The system will be thermally operational under the following condition: one single fan within the fan unit fails at the maximum air temperature (55° C)
• A red LED indicates the operating status of the fans
Fig. 173 SURPASS hiT7300 Fan unit
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 180
5.2.6 Connector Panel
The connector panel (COPA) is placed inside the shielded room at the bottom edge of the SURPASS hiT7300 sub-rack. The external management and power supply connectors of the sub-rack are centralized on its connector panel. There is also EMI filter elements.
The COPA connectors are listed in the following table:
Connector Name
Connector Type
Remarks
UBAT 1/3; UBAT 2/4
3W3 D-Sub For connection of shelf DC operating voltage (redundant power feeds from the rack Fuse Panel)
APSD IN; ASPD OUT
8-pin RJ45 Input and output connectors for the amplifier card Automatic Power Shutdown (APSD) bus. APSD signaling is daisy-chained from shelf -to-shelf via cable using these connectors
GND M4 threaded stud
Shelf grounding cable must be attached here
FAN ALARM
SURPASS hiT 7300SIEMENS
UBAT2/4 (304)
GND (305)
APSD OUT (303)
APSD IN (302)
UBAT1/3 (301)
DANGER: ROTATING FANS
Fig. 174 Connector panel (COPA)
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
181
5.2.7 Cable outlet
In order to minimize the rack spacing of the sub-racks, the outlets of the optical cables is available in front of the rack beams. Each sub-rack has a cable outlet which is placed below the screened room of the sub-rack. All cables can be bent over defined radius (radius of bend = 30 mm) in order to avoid any problems with transmission of the optical signals.
Cable outlet
Fig. 175 Cable outlet
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 182
5.3 RMH07 series Sub-Rack The RMH07 sub-rack has been designed to safely and securely fit into ETSI standard racks (600mm width by 300mm depth). A spacing clearance of 200mm or more must be left on top the RMH equipment to provide proper heat exhaust. No spacing clearance is required at the bottom of the equipment.
A maximum of two RMH07 sub-racks can be installed in a 2200mm ETSI rack. Allocating 0.80 m of vertical rack space to each RMH07, the remaining of the rack space will be used by the power distribution and management monitoring equipment. The RMH07 sub-rack has three compartments – the cable shelf, card shelf and fan shelf.
The fan shelf accommodates up to three Environmental Control Units (ECU). The fan shelf provides power and monitor signal connections for the ECU's via the backplane.
The card shelf contains the main electronic components of the RMH07. The card shelf compartment is protected with a removable hinged door. There are 23 slots in the card shelf section of the RMH07 with a slot spacing of 20 mm (0.79”). Forced air is circulated from bottom to top via the ventilated card guide. The card shelf provides power, control and monitor signal connections for the PIU via the backplane. Encoding keys prohibit the user from inserting a card in the wrong location.
All external electrical and optical connections to and from the RMH07 sub-rack are made through the cable shelf compartment. Electrical connections are made to/from the backplane, whereas the optical connections are through the fiber fingers between the card shelf and the cable shelf compartments.
FAN SHELF
CARD SHELF
CABLE SHELF
Fig. 176 RMH07 series Sub-Rack
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
183
RMH07 typical configurations are shown in the following figure:
Typical Configuration: 24 dBm Booster, 1.5 W Raman
max: 5 MLUsmin: 4 MLUs
DXXXXSMF
In Out
DXXXXSMF
In Out
DXXXXSMF
In Out
MLU MLU
F40-1
COM
P15F
SIG
IN
SIG
OU
T
MON. OUT
P17F
SIG
IN
SIG
OU
T
MON. OUT
OSU
OSCOUT
OSCIN
RCU 1,5W
OS
CO
UT
OS
CO
UT
OTDR(APC)
RAMANMONITOR
INPUTFROMLINE
SIGNALOUTPUT
SEE
D1
SEE
D2
SLU SLU OSU
OSCOUT
OSCIN
FIXED ATTENUATOR
EITHER VOAS OR FIXED ATTENUATORS
I01T10G-1LHD
Clie
nt
Lin
eTx
Rx
Rx
Tx
I08T10G-1LHD
Line
Clie
nt
Rx5Tx5
Rx6Tx6
Rx7Tx7
Rx8
Tx1
Rx2Tx2
Rx3Tx3
Rx4Tx4
Tx
RxTx8
Rx1
O08VA-1
VOAIN1OUT1
VOAOUT2IN2
VOAIN3OUT3
VOAOUT4IN4
VOAIN5OUT5
VOAOUT6IN6
VOAIN7OUT7
VOAOUT8IN8
F40-1
COM
P24F
SIG
IN
SIG
OUT
OSC IN
OSC IN
BACK REFL.
MON. OUT
FIXED ATTENUATORS
**
Fig. 177 RMH07 typical configuration_1
1 232221191816 17 201098642 3 5 7 1514131211
RMH-ECU RMH-ECURMH-ECU
RMH-PLF RMH-PLF
unus
ed
RM
H-M
LU-2
000
RM
H-M
LU-2
000
RM
H-M
LU-2
000
RM
H-M
LU-2
000
RM
H-M
LU-2
000
RM
H-S
LU-3
60/1
454
RM
H-S
LU-3
60/1
454
u nus
ed
RM
H-O
SU
/157
4
RM
H-O
SU
/157
4
unus
ed
RM
H- A
SU
RMH-RCU-RFL-1500-1426/1454-S2-C5-I1
RM
H-P
15F
unus
ed
unus
ed
RM
H-P
17F
RM
H-P
24F
Fig. 178 RMH07 typical configuration_2
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 184
5.4 Mechanical design of modules
5.4.1 Basic card design
Each card consists of a multi-layer PCB with a surrounding ESD grounding frame and a face plate. The components are fitted on both sides of the PCB.
The SIPAC connectors at the rear of the card as well as the corresponding SIPAC connectors on the sub-rack backplane are fitted with mechanical card coding elements. Each card can only be fully inserted into a sub-rack slot that is suitable for this card, so that fundamental sub-rack equipping errors (which possibly might cause damages or extensive malfunctions) are impossible. These mechanical coding elements also ensure the proper centering and grounding of the card in the sub-rack. All cards have insertion and removal aids that fit into the holes of the card guides in the sub-rack. No special tools are necessary for inserting or extracting the cards.
WARNING Note that installing cards requires slow and careful handling. Never apply excessive force!
Cards comprise all devices PCB (printed circuit boards) which can be installed by a simple plug-in procedure. Each card can be fixed with captive screws on the top and bottom card levers. The grounding pins of the SIPAC connectors are pre-mating, so that they first of all establish the ground connection, when the card is being inserted into the sub-rack.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
185
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mechanical Coding
SIPAC Connector
Printed Circuit Board (PCB)
Insertion and removal aid
Insertion and removal aid
Fig. 179 Basic card design
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 186
5.4.2 Card faceplate LED's
Each "active" card, i.e., those that contain an on-board processor, has a green OK LED and a red Fault LED on its faceplate that indicates card status. "Passive" cards (e.g., Filter cards) do not have any LED's.
The following information can be obtained from the "OK" LED and from the "Fault" LED:
Element Color Explanation
OK LED Green When the OK LED is on, it indicates that the card is powered, operating fault-free, and is capable of carrying traffic
Fault LED
Red When the Fault LED is on, it indicates that the card has detected an on-board hardware or software failure. When the failure condition clears, the Fault LED is extinguished. The Fault LED is powered by a backplane power bus, ensuring that a card can light its Fault LED even if its own on-board power supply fails
CC
SP
Lever
Fault
OK
1
2
ACO
Upper insertion / extraction aid
Upper insertion / extraction aid
“Fault” LED and “OK” LED“Fault” LED
and “OK” LED
Fig. 180 Card faceplate LED's
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
187
5.4.3 Cards and optical connectors labeling
The visible surfaces of the insertion and removal aids are used for card identifying labels.
The front panel of an optical card is either fitted with optical fiber connectors or with SFP modules. The available fiber connector variants, depending on the card types, are listed in TED.
F4 -OutF4-In
F3 -OutF3-In
F2 -OutF2-In
F1 -OutF1-In
1C-Out2C-In
DxOutMxIn
Card Labelling
Optical Connectors
Optical ConnectorsLabelling
Fig. 181 Example of the cards and optical connectors labeling
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 188
5.5 SURPASS hiT7300 optical cabling SURPASS hiT7300 equipment operates at high laser power levels. Use extreme caution when connecting or disconnecting fiber, since high optical power levels can be present at card connectors or fiber ends.
WARNING Never look directly into the end of a fiber, patchcord, fiber pigtail or card connector until you are sure that no light is present. Permanent eye damage or blindness can result if exposed to such optical power levels - even for extremely short durations.
In order to avoid cable damage when routing the optical connections, the following fiber guiding parts of the system have to be used:
• Fiber duct: Supports safe fiber routing from rack to rack.
• Edge protection: Avoids bending of optical fiber running from or to the fiber guides of a shelf (shelf-to-shelf connections).
• Cable slots: After connecting the fibers at the cards they have to be guided through the cable slots. In combination with adjacent space and the bending radius (25 mm) given by the guiding plastic parts, this will avoid accidental crimping and squeezing of the optical fiber.
After connecting the cables at the plug-in modules, they have to be run through the cable slots. Then the cable has to be bent sideward. In order to avoid cable squeezing, the cables are bent over plastic parts. Distribute the cables in the cable ducts symmetrically. Therefore, usage of the left or right side of the bay has to be checked in any case.
The cables are handled sideward to the cable outlets of the shelf. Over length (slack) must be stored in the cable compartment.
The minimum bending radius of the optical cables is 25 mm. The cable slots directly below the plug-in module have to be used.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
189
Fig. 182 Shelf Cable Duct (example)
Fig. 183 Edge protection (example)
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 190
Fig. 184 Fiber Tray (example).
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
191
6 Exercise
Fig. 185
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 192
Exercise 1
Title: Hardware and Functionality
Objectives: Demonstrate that you know the main functions of the hardware of SURPASS hiT7300
Pre-requisite: Pre-read chapter "Hardware and Functionality;
Physical access to the equipments.
Task 1
Please form four teams. Ask your instructor for the name of your team (e.g. student01) and write it down in the field below:
I am working with the team: student _ _
Fig. 186 Login information
Go to the LAB and dependent on the team number, you are responsible for the following NE:
Case of LAB1:
Group Name NE Name Row/Rack
Student01 Dresden 06 / 002
Student02 Hannover 06 / 007
Student03 Berlin 06 / 012
Student04 Jena 06 / 022
Student05 Weimar & Muenster 06 / 017
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
193
Case of LAB2:
Group Name NE Name Row/Rack
Student01 Goslar 07 / 502 & 07 / 507
Student02 Olpe 07 / 507
Student03 Unna 07 / 512
Student04 Rastatt 07 / 517
Student05 Kamenz 07 / 522
Each team shall verify and write down in the table below the name of cards and the slot number where this card is inserted to for the NE assigned.
NE Name: ________________
Shelf 1 Shelf 2 Shelf 3
Slot Card Slot Card Slot Card
001 001 001
002 002 002
003 003 003
004 004 004
005 005 005
006 006 006
007 007 007
008 008 008
009 009 009
010 010 010
011 011 011
012 012 012
013 013 013
014 014 014
015 015 015
016 016 016
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 194
Task 2
Using the information from the previous task (card types available in the NE assigned to your team), try to find out which hiT7300 NE type it is.
In the table below marked the correct NE type of the NE assigned to your team.
NE Type Which NE type is assigned to my team?
OLR
ONN-T
ONN-I
ONN-R
ONN-S
ONN-X
SON
TIP Discuss in class the obtained results.
Task 3
In order to understand the optical signal flow each team shall write down the optical cable numbers of the NE in the appropriate fields of the cabling plan attached to this exercise.
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
195
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Direction
Muenster
Direction
Hannover
In
MonSo
OutVOA
LASBC-1SR 1 Sl 14
1C-OUT
2C-IN
R-IN
R-OUT
C06-IN
C06-OUT
F08-SB1
1C-OUT2C-IN
C08-IN
C08-OUT
F16SB-R
A
B
C
D
1C-OUT
2C-IN
F04MDN-1/C08
F1
O08VA-1
IN3
Rx
VOA
VOA
SR1 Sl 8
SR1 Sl 13
SR1 Sl. 6
1C-OUT
2C-IN
194.0
F04MDN-1/C06
OUT
SR1 Sl 12
SR3 Sl 3
ClientLine
I01T10GSR3 Sl.6
O08VA-1
VOA
VOA
SR3 Sl 1
F1
OUT
F2
OUT
193.1 IN4
OUT4
Tx
OUT3
OUT4 IN4IN
IN
Cli
en
tL
ine
I04
T2
G5
SR
3 S
l15
Rx
1
Tx1
IN3
OUT3
IN
LAxPC-1 Sl 7
In
MonSo
Out
From ISDTo ISD
VOA
LAMPC-1SR 1 Sl 11
DCM
SR1 Sl 9
LAxPC-1 Sl 7
In
MonSo
Out
From ISDTo ISD
VOA
LAMPC -1SR 1 Sl 4
DCM
SR1 Sl 2
In
MonSo
OutVOA
LASBC - 1SR 1 Sl 7 1514
5dB
DxOUT
MxIN
2C-IN
1C-OUT
F04MDU-1/C06
SR1 Sl 3
DxOUT
2C-IN
1C-OUT
F04MDU-1/C08
SR1 Sl 5
O0
8VA
-1
IN1
VO
A
VO
A
SR
3 S
l3
OU
T1
OU
T2
IN2
F1
OUT
194
.0
IN
O0
8VA
-1
IN2
VO
A
VO
A
VO
A
SR
3 S
l2
OU
T2
OU
T8
IN8
F1IN
OUT
193
.2C
lie
nt
Lin
e
I04
T2
G5
SR
3 S
l15
Rx
2
Rx2
Tx
2
Tx2
F2
IN4
19
3.1
OUT
OU
T4
IN2
OU
T2
F3
F4
MxIN
F2
F3
F4
5dB
F3
F4
F2
F3
F4
1515
1513
1516
.
.
.
hiT7300 ONN-I; NE Name: DresdenRow/Rack/Subrack: 06/002/02-04
To
/Fro
m O
DF
To
/Fro
m O
DF
To
/Fro
m O
DF
To
/Fro
m O
DF
Last changes: 28.01.2008
In Out
In Out
OUT
193.8
O08VA-1
VOA
VOA
SR3 Sl 2IN6 OUT6
INClientLine
I04T2G5SR3 Sl.4
IN7OUT7
OUT
193.7
O08VA-1SR3 Sl 1
IN1OUT1
193.7
Clie
nt
Lin
e
I04
T2
G5
SR
3 S
l4
Rx
1
Tx
1
IN
O0
8V
A-1
VO
A
SR
3 S
l1
VOA
O08VA-1SR3 Sl 2
IN1 OUT1VOA
Tap1
MonP1
Tap2 Tap3
Tap4
MonP2
MonP3
MonP4
OSA
MCP404-2SR1; SL1
2dB
O0
3C
P-1
SR
3 Sl.7
Line1In
Line1Out
Prot1In
Prot1Out
RxClientLine
I01T10GSR3 Sl 5
Tx
Tx
Rx
2dB
Tx
Rx
IN
OUT
Fig. 187 NE Dresden SR1&SR3
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 196
hiT7300 ONN-I; NE Name: DresdenRow/Rack/Subrack: 06/002/02-04
Last changes: 28.01.2008
Direction
Jena
LAxPC-1 Sl 7
In
MonSo
Out
From ISDTo ISD
VOA
LAMPC -1SR 2 Sl 4
DCM
SR2 Sl 2
DxOUT
MxIN
2C-IN
1C-OUT
F04MDU-1/C08
SR2 Sl 5
DxOUT
2C-IN
1C-OUT
F04MDU-1/C06
SR2 Sl 8
F1
OUT
194.0 INF1IN
OUT
193.2
Cli
ent
Lin
e
I04
T2
G5
SR
2
Sl.
6
Rx1
Tx1
F2OUT
F3
F4
MxIN
F2
F3
F4
1120
O08VA-1
IN8
SR3 Sl 1
OUT1
OUT7 IN7
To
/Fro
m O
DF
To
/Fro
m O
DF
In Out
193.7
IN
Ta
p1
Mo
nP
1
Ta
p2
Ta
p3
Ta
p4
Mo
nP
2M
on
P3
Mo
nP
4
OS
A
MC
P40
4-2S
R2; S
L1
2dB
IN
OUT
MonSo
Out
LIFB-1SR 2 Sl 7
In1119
VOA
VOA
O08VA-1
IN6
SR3 Sl 1
OUT61
OUT5 IN5
VOA
VOA
LIN
ER
x
Tx
CLI
ENT
Rx
8Tx
8
Rx
7Tx
7
Rx
6Tx
6
Rx
5Tx
5
Rx
3Tx
3R
x4
Tx4
Rx
2Tx
2
Rx 1
Tx1
I08T
10G
-1S
R2
Sl
9
Fig. 188 NE Dresden SR2
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
197
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DirectionDirection
Dresden
In
MonSo
OutVOA
LASBC-1SR 1 Sl 14
1C-OUT
2C-IN
R-IN
R-OUT
C06-IN
C06-OUT
F08-SB1
1C-OUT
2C-IN
C08-IN
C08-OUT
F16SB-R
A
B
C
D
1C-OUT
2C-IN
F04MDN-1/C08
F1
SR2 Sl 15
SR1 Sl 15
SR1 Sl 8
F2
OUT
193.1
Clie
nt
Lin
e
I04
T2
G5
SR
2 Sl3
Tx1
Rx2
O0
8V
A-1
SR
2 Sl1
IN3
OU
T3
IN4
OU
T4
IN
LAxPC-1
In
MonSo
Out
From ISDTo ISD
LAMPC-1SR 1 Sl 11
DCM
SR1 Sl.12
LAxPC-1 Sl7
In
MonSo
Out
From ISDTo ISD
VOA
LAMPC-1SR 1 Sl 4
DCM
SR1 Sl.2
In
MonSo
OutVOA
LASBC-1SR 1 Sl 7 1520
5dB
DxOUT
MxIN
2C-IN
1C-OUT
F04MDU-1/C08
SR1 Sl 06
DxOUT
2C-IN
1C-OUT
F04MDU-1/C06
SR1 Sl 5
F1
OUT
194.0IN
OU
T3
IN4
F1 IN
OUT
193.2
Rx2
Rx1
Tx1
Tx
2
F2
F3
F4
MxIN
F2
F3
F4
5dB
F3
F4
1519
1518
1C
-OU
T
2C-IN
19
4.0
F0
4M
DN
-1/C
06
OU
T
SR
1 Sl10
IN
F1
F2
F3
F4
hiT7300 ONN-I; NE Name: HannoverRow/Rack/Subrack: 06/007/02-03
To
/Fro
m O
DF
To
/Fro
m O
DF
To
/Fro
m O
DF
To
/Fro
m O
DF
Last changes: 28.01.2008
In Out
IN1
SR
2 Sl1
IN3
OU
T6
IN6
OU
T5
IN5
OU
T4
In Out
1517 VOA
IN7OUT7
19
3.7
Client Line
I04T2G5SR2 Sl13
O08VA-1SR2 Sl 1
Tx2 IN2 OUT2
OU
T
IN
O0
8V
A-1
SR
2 Sl2
O0
8V
A-1
SR
2 Sl2
193
.8
OU
T
IN
IN
VO
A
VO
A
Clie
nt
Lin
e
I04
T2
G5
SR
2 Sl3
VO
A
VO
A
193.1
OUT
Clie
nt
Lin
e
I04
T2
G5
SR
2 Sl13
VO
A
OUT1
IN8
O0
8VA
-1S
R2 S
l2
VO
A
OU
T8
OUT
IN 193.8
O0
8V
A-1
SR
2 Sl2
IN2
VO
A
OU
T2
O0
8V
A-1
VO
A
IN1
OUT1
Rx1
VO
A
VO
A
Berlin
Tap4
MonP4
Tap3 Tap2
Tap1
MonP3
MonP2
MonP1
OSA
MCP404-2SR1; SL1
2dB2dB
O08VA-1SR2 Sl 2
VOA
VOA
Fig. 189 Hannover SR1&2
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 198
Direction
Muenster Direction
Hannover
LAxPC-1 Sl7
In
MonSo
Out
From ISDTo ISD
VOA
LALPC -1SR1 Sl 4
DCM
SR1 Sl 2
In
MonSo
OutVOA
LALBC -1SR 1 Sl 7 1601
5 dB
DxOUT
MxIN
2C-IN
1C-OUT
F04MDU-1/C06
SR1 Sl 5
DxOUT
2C-IN
1C-OUT
F04MDU-1/C08
SR1 Sl 8
O08V
A-1
IN2
VO
A
VO
A
SR
2 S
l1
OU
T2
OU
T1
IN1
F1OUT
194.
0
IN
Rx
Clien
tL
ine
I01T
10G
SR
2 S
l5
Tx
F1IN
F2
OUT
F3
F4
MxIN
F2
F3
F4
In
MonSo
Out
LASBC-1SR 1 Sl 14
5dB
1604
..
hiT7300 ONN-I; NE Name: BerlinRow/Rack/Subrack: 06/012/02-03
To
/Fro
m O
DF
To
/Fro
m O
DF
Last changes: 28.01.2008
O08VA-1
VOA
VOA
SR2 Sl 1
IN5OUT5OUT4
Clien
tL
ine
I04T
2G
5S
R2 S
l4
Rx1
Tx1
IN4
LAxPC-1 Sl7
In
MonSo
Out
From ISDTo ISD
VOA
LAMPC-1SR 1 Sl 11
DCM
SR1 Sl12
1602
In Out
In Out
DxOUT
MxIN
2C-IN
1C-OUT
F04MDU-1/C06
SR1 Sl 10
DxOUT
2C-IN
1C-OUT
F04MDU-1/C08
SR1 Sl 9
F1OUT 194.0
IN F1 IN
OUT
193.2
F2 193.1
OUT
F3
F4
MxIN
F2
F3
F4
O08V
A-1
IN4
VO
A
VO
A
SR
2 S
l2
OU
T4
OU
T3
IN3
Rx
Clien
tL
ine
I01T
10G
SR
2 S
l6
Tx
In )
PRC-1
Out
Mon LineMon PRC
SR2 SL14
1603
From ISDTo ISD
O08
VA
-1
IN8
VO
A
VO
A
SR
2
Sl
1
OU
T8
OU
T6
IN6
Rx2
Cli
ent
Lin
e
I04
T2
G5
SR
2
Sl.
10
Tx2
OUT
193.8
To
/Fro
m O
DF
To
/Fro
m O
DF
VOA
O08V
A-1
SR
2 S
l1
IN3
OU
T3
VO
A
193.7
O08V
A-1
SR
2 S
l2
IN2
OU
T2
VO
A
OUT
Clien
tL
ine
I04T
2G
5S
R2
Sl
4
Rx2
Tx2
OUT6
Cli
ent
Lin
e
I04
T2
G5
SR
2
Sl1
0
Rx1
Tx1
OUT
193.1
O08VA-1SR2 Sl 2
VO
A
IN5
OU
T5
IN
IN1OUT1VOA
O08VA-1SR2 Sl 2
193.2
O08V
A-1
SR
2 S
l2
IN7
VO
AO
UT
7
Tap1
MonP1
Tap2 Tap4
Tap3
MonP2
MonP4
MonP3
OSA
MCP404-2SR1; SL1
2dB
2dB
IN
IN6VOA
5dB2dB
O03C
P-1
SR
2 S
l.3
Line1In
RxTx
Line1Out
RxTx
Prot1In
IN
O08V
A-1
SR
2 S
l2
Prot1Out
Fig. 190 NE Berlin SR1&2
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
199
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tap4
MonP4
Tap3 Tap2
Tap1
MonP3
MonP2
MonP1
OSA
MCP404-2SR1; SL15
2dB
hiT7300 ONN-R; NE Name: JenaRow/Rack/Subrack: 06/022/02-03
Last changes: 28.01.2008
DirectionDresden
LAxPC-1 Sl7
In
MonSo
Ou
t
From ISDTo ISD
VOA
LAMPC-1SR 1 Sl 4
DCM
SR2 Sl 1
1209
MonSo
Out
LIFB-1SR 1 Sl 7
In
In Out
2dB
1210
VOA VOA VOAVOA
F40 MR-1SR 2 Sl 6
RX
-IN
192.
1
195.
7
196 .
0
195.
9
195.
8
194 .
0
193 .
2
COM
F4
0-1
SR
1 S
l13
RX-
OU
T2
TX-O
UT
O08
VA
-1S
R2
S
l.4
IN1
VO
AC
lien
tL
ine
I04
T2
G5
SR
1
Sl
1
Rx1
Tx1
OU
T1
193.2
VOAVOAVOA VOA
F40 MR-1SR 1 Sl 9
DirectionWeimar
LAxPC-1 Sl7
In
MonSo
From ISDTo ISD
VOA
LAMPC-1SR 1 Sl 11
DCM
SR2 Sl14
1211
InOut
MonSo
Out
LIFB-1SR 1 Sl 14
In1212
RX
-IN
192.1
195.7
196.0
195.9
195.8
194.0
193.2
COM
F4
0-1S
R1 S
l. 6
RX-
OU
T2
TX-O
UT
RX-OUT1
EXP-IN
O08V
A-1
SR
2 S
l.4IN
2V
OA
Clien
tL
ine
I04T
2G
5S
R1
Sl
1
Rx2
Tx2
OU
T2
RX-
OU
T1
EXP-IN
193.2
194.0
194.0
To
/Fro
m O
DF
To
/Fro
m O
DF
To
/Fro
m O
DF
To
/Fro
m O
DF
Fig. 191 NE Jena SR1&2
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 200
DirectionJena
LAxPC-1 Sl7
In
MonSo
Out
From ISDTo ISD
VOA
LAMPC-1SR 1 Sl 4
DCM
SR1 Sl 5
1118
MonSo
Out
LIFB-1SR 1 Sl 7
In
COM
192.1
195.7
194.0
196.0
195.9
195.8
193.2
192.1
195.7
.
196.0
195.9
195.8
194.0
193.2
In Out
Tap4
MonP4
Tap3 Tap2
Tap1
MonP3
MonP2
MonP1
OSA
MCP404-2SR1; SL3
2dB
2dB
F40-1SR1 Sl 9
COM
F40-1SR1 Sl 2
Rx1
Tx1Client Line
I04T2G5SR1 Sl 10
O08VA-1SR1 Sl13
IN1OUT1VOA
LINERx
Tx
CLIENT
Rx8Tx8
Rx7Tx7
Rx6Tx6
Rx5Tx5
Rx3Tx3Rx4Tx4
Rx2Tx2
Rx1Tx1
I08T10G-1SR1 Sl 11
O08VA-1SR1 Sl13
IN2OUT2
O08VA-1SR1 Sl13
IN4 OUT4VOA
O08VA-1SR1 Sl13
IN3 OUT3VOA
1117
VOA
hiT7300 ONN-T; NE Name: WeimarRow/Rack/Subrack: 06/017/03
To
/Fro
m O
DF
To
/Fro
m O
DF
Fig. 192 NE Weimar SR1
LineSignal
out
Mon LineMon RPump
In
MonSo
Out
From ISDTo ISD
VOA
Direction1
Berlin
Direction2
Dresden
In
MonSo
Out
From ISD To ISD
LALIC-1 SR1 Sl 7
VOA
DCM
SR1 Sl 1 InOut
LALIC-1 SR1 Sl 10 PRC-1 SR1 Sl 14
DCM
SR1 Sl12
hiT7300 OLR; NE Name: MuensterRow/Rack/Subrack: 06/017/02
To
/Fro
m O
DF
To
/Fro
m O
DF
To
/Fro
m O
DF
To
/Fro
m O
DF5 dB
In Out
Fig. 193 NE Muenster SR1
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
201
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LAxPCOut
VOA
In
MonSo
Sl 7Out
VOA
In
MonSo
In
MonSo
Out
VOA
In
MonSo
Out
VOA
COM
196.00
193 .80
192.10
193.20WSS 1X8TX - IN 1
TX - IN2
TX - IN3
TX - IN4
TX - IN5
TX
-OU
T
VOA
RX - OUT 1
RX - OUT 2
RX - OUT 3
RX -OUT 4
RX -OUT 5RX
- IN
MD
40 %
60 %
COM
196.00
193 .80
192.10
193.20
VOA
VOA
VOA
VOA
MD
RX - OUT 6
RX - OUT 7
RX - OUT 8
TX - IN6TX - IN7
TX - IN8
COM
196.0 0
193 .8 0
192 .10
193 .20
COM
196.00
193.80
192.10
193.20
VOA
VOA
VOA
VOA
WSS 1 X8TX - IN1
TX - IN2
TX - IN3
TX - IN4
TX - IN5TX-OUT
VOA
RX - OUT1
RX - OUT2
RX - OUT3
RX - OUT4
RX - OUT5
MD
40 %
60 %
MD
RX - OUT6
RX - OUT7
RX -OUT8
TX - IN6TX - IN7
TX - IN8
OSA
WSS
1X
8TX
-IN
1
TX-I
N2
TX-I
N3
TX-I
N4
TX-I
N5
TX-OUT
VOA
RX
-OU
T1
RX
-OU
T2
RX
-OU
T3
RX
-OU
T4
RX
-OU
T5
RX-IN-
MD40
%
60%
RX
-OU
T6
RX
-OU
T7
RX
-OU
T8
TX-I
N6
TX-I
N7
TX-I
N8
In
MonSo
OutSl 7
Out
From ISD
VOA
In
MonSo
IO4T2G5-1SR2; SL. 9
Lin
e
Clie
nt
LAMPC-1SR3; SL. 4
To ISDDCM
Slot 92
LAMPC-1SR1; SL. 4
InOut
F08M
R-1
; SR
1; S
L. 8
LAMIC-1SR1; SL. 7
VOA
F08MR-1; SR2; SL. 1F08MR-1; SR3; SL. 8
From ISD To ISD
LAMPC-1SR2; SL. 11
From ISD To ISDDCM
SR2; Sl.7InOut
MC
PSR
1; S
L. 2
Ta
p4
Mo
nP
4M
on
P3
Mo
nP
2M
on
P1
Ta
p3
Ta
p1
Tap
2
RX-IN
F40V-1/SSR2; SL. 3
F40-1/SSR2; SL. 6
From ISDTo ISD
LAMIC-1SR2; SL. 14
Rx2
IO4T2G5-1SR2; SL. 10L
ine
Clie
nt
Rx1
Tx2
Tx1
From ISD To ISDDCM
Sr3 Sl.10InOut
OSA M
CP
SR3; SL.3
Tap
4
Mo
nP
4M
on
P3
Mo
nP
2M
on
P1
Tap
3
Tap
1
Tap
2
F40V-1/SSR3; SL. 1
F40-1/SSR3; SL. 6
LAMIC-1SR3; SL. 7
IO4T2G5-1SR2; SL. 9
Lin
e
Cli
en
t
IO4T2G5-1SR2; SL. 10
Lin
e
Cli
en
t
Tx1
Tx2
Rx1
Rx2
From ISD To ISD
2dB
5dB
5dB
5dB
2dB
10dB
5dB
2dB
10dB
Direction
Olpe
1131
1141
Direction
Unna
1331
1311
Direction
Rastatt
1121
1111
hiT7300 ONN-X; NE Name: Goslar
Row/Rack/Subrack: 07/502/02-0407/507/02
Last changes: 04.02.2009
Fig. 194 Goslar SR1, 2&3
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 202
hiT7300 ONN-S; NE Name: OlpeRow/Rack/Subrack: 07/507/02
Last changes: 04.02.2009
Direction
Goslar
DxOUT
MxIN
2C-IN
1C-OUT
F04MDU-1/C06
SR1 Sl 3
F1
OUT
IN 193.8
F2
F3
F4 193.7INOUT
LAxPC-1 Sl7
In
MonSo
Out
From ISDTo ISD
VOA
LAMPC -1SR 1 Sl 4
DCM
SR1 Sl 1
1242
In Out
MonSo
Out
LIFB-1SR 1 Sl 7
In1232
Direction
Kamenz
LAxPC-1 Sl7
In
MonSo
Out
From ISD To ISD
VOA
LAMPC-1SR 1 Sl 11
DCM
SR1 Sl 12
1142
InOut
MonSo
Out
LIFB-1SR 1 Sl 14
In 1132
DxOUT
MxIN
2C-IN
1C-OUT
F04MDU-1/C06
SR1 Sl 15
F1
OUT
IN193.8
F2
F3
F4193.7 IN
OUT.
Cli
ent
Lin
e
I04
T2
G5
SR
1
Sl.
5
Rx1
Tx1
O08
VA
-1
IN2
SR
1 S
l6
OU
T2
OU
T4
IN4
Clien
tL
ine
I04T
2G
5S
R1
Sl.1
0
IN3
OU
T3
VO
A
VO
A
Rx2
VO
A
VO
AIN
1
Tx2
OU
T1
Clien
tL
ine
I04T
2G
5S
R1
Sl.5
Rx2
Tx2
OU
T6
Cli
ent
Lin
e
I04
T2
G5
SR
1
Sl.
10
IN7
Rx1
Tx1
OU
T5
IN8
OU
T8
VO
A
OU
T7
VO
A
VO
AIN
5
O08V
A-1
SR
1 S
l6
IN6
VO
A
5dB
5dB
Fig. 195 Olpe SR1
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
203
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DirectionGoslar
LAxPC-1 Sl7
In
MonSo
Out
From ISDTo ISD
VOA
LAMPC-1SR 1 Sl 4
DCM
SR1 Sl 92
1342
MonSo
Out
LIFB-1SR 1 Sl 7
In
COM
192.1
194.4
194.0
196.0
195.9
195.8
193.7
192.1
194.4
.
196.0
195.9
195.8
194.0
193.7
In Out
Tap4
MonP4
Tap3 Tap2
Tap1
MonP3
MonP2
MonP1
OSA
MCP404-2SR1; Sl 5
5dB
2dB
F40V-1/SSR1 Sl 8
COM
F40V-1/SSR1 Sl 2
Rx2
Tx1
Client Line
I04T2G5SR1 Sl 12
LINERx
Tx
CLIENT
Rx8Tx8
Rx7Tx7
Rx6Tx6
Rx5Tx5
Rx3Tx3Rx4Tx4
Rx2Tx2
Rx1Tx1
I08T10G-1SR1 Sl 10
1322
hiT7300 ONN-T; NE Name: UnnaRow/Rack/Subrack: 07/512/02
Last changes: 04.02.2009
Rx1
Tx1Client Line
I01T10GSR1 Sl 6
193.1
Rx1
193.1
Tx2
Fig. 196 Unna SR1
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 204
Direction
Goslar
DirectionKamenz
In
MonSo
OutVOA
LASBC-1SR 1 Sl 14
1C-OUT
2C-IN
R-IN
R-OUT
C06-IN
C06-OUT
F08-SB1
1C-OUT2C-IN
C08-IN
C08-OUT
F16SB-R
A
B
C
D
1C-OUT2C-IN
F04MDN-1/C08
F1
SR1 Sl 9
SR1 Sl 15SR2 Sl. 15
1C-OUT
2C-IN
194.0
F04MDN-1/C06
OUT
SR1 Sl 10
F1
OUT
F2
OUT
193.2
IN
IN
IN
LAxPC-1 Sl7
In
MonSo
Out
From ISDTo ISD
VOA
LAMPC-1SR 1 Sl 11
DCM
SR1 Sl 12
LAxPC-1 Sl7
In
MonSo
Out
From ISDTo ISD
VOA
LAMPC-1SR 1 Sl 4
DCM
SR1 Sl 5
In
5dB
F3
F4
F2
F3
F4
1222
1122
1212
hiT7300 ONN-I; NE Name: RastattRow/Rack/Subrack: 07/517/02-03
Last changes: 04.02.2009
In Out
In Out
OUT
193.8IN
OUT
193.7
Tap1
MonP1
Tap2 Tap3
Tap4
MonP2
MonP3
MonP4
OSA
MCP404-2SR1; SL2
5dB
IN4
Rx2
Tx2
Clien
tL
ine
I04T
2G
5S
R2
Sl.1
4
MonSo
Out
LIFB-1SR 1 Sl 7
In
1C-OUT
2C-IN
R-IN
R-OUT
C06-IN
C06-OUT
F08-SB1
1C-OUT
2C-IN
C08-IN
C08-OUT
F16SB-R
A
B
C
D
SR1 Sl 1SR2 Sl. 1
1C-OUT2C-IN
F04MDN-1/C08
F1
SR1 Sl 8
OUT
F2
OUT
193.1
IN
IN
F3
F4
1C-OUT
2C-IN
194.0
F04MDN-1/C06
OUT
SR1 Sl 3
F1IN
F2
F3
F4
OUT
193.8 IN
OUT
193.7
Rx1
Tx1
Cli
ent
Lin
e
I04
T2
G5
SR
2
Sl.
14
Rx1
Tx1
Clien
tL
ine
I04T
2G
5S
R2
Sl.2
193.2
IN3
OU
T3
OU
T5
IN5
OU
T6
O08
VA
-1S
R2
S
l3
VO
A
VO
A
VO
A
VO
A
IN6
IN4
OU
T4
IN2 OUT2IN8
O08VA-1SR2 Sl 3
VOAO
08V
A-1
SR
2
Sl
4
IN2
Rx2
Tx2
Clien
tL
ine
I04T
2G
5S
R2
Sl.2
OUT2
OUT8
VOA
IN3
OUT3
VO
A
OUT1
VO
A
IN1
VO
A
O08
VA
-1
VO
A
SR
2
Sl
4
OUT4
OUT7
VOA
IN1 OUT1
VOA IN7
1112
Fig. 197 Rastatt SR1&2
Hardware & Functionality
FT22124EN03GLA0 © 2011 Nokia Siemens Networks
205
Tap4
MonP4
Tap3 Tap2
Tap1
MonP3
MonP2
MonP1
OSA
MCP404-2SR1; SL15
hiT7300 LAB2 ONN-R; NE Name: Kamenz
Row/Rack/Subrack: 07/522/02-03
Last changes: 04.02.2009
DirectionOlpe
LAxPC-1 Sl7
In
MonSo
Ou
t
From ISDTo ISD
VOA
LAMPC-1SR 1 Sl 4
DCM
SR1 Sl 2In Out
2dB
VOA VOA VOAVOA
F40 MR-1SR 1 Sl 9
RX
-IN
192.
1
195.
7
196.
0
195.
9
195 .
8
194.
0
193.
7
COM
F40
-1/S
SR
1 S
l13
RX-
OU
T2
TX-O
UT
O08
VA
-1S
R2
Sl.
5IN
1C
lien
tL
ine
I04
T2
G5
SR
2
Sl
4
Rx1
Tx1
OU
T1
193.7
VOAVOAVOA VOA
F40 MR-1SR 2 Sl 14
DirectionRastatt
LAxPC-1 Sl7
In
MonSo
From ISDTo ISD
VOA
LAMPC-1SR 1 Sl 11
DCM
SR2 Sl11
1231
InOut
MonSo
Out
LIFB-1SR 1 Sl 14
In1241
RX
-IN
192.1
195.7
196.0
195.9
195.8
194.4
193.7
COM
F4
0-1/SS
R1 S
l. 6
RX-
OU
T2
TX-O
UT
RX-OUT1
EXP-IN
O08V
A-1
SR
2 S
l.5IN
4V
OA
Clien
tL
ine
I04T
2G
5S
R2
Sl
4
Rx2
Tx2
OU
T4
RX-
OU
T1
EXP-IN
193.7
194.4
194.0
In
MonSo
Out
LASBC-1SR 1 Sl 7 1221
10dB
VOA
VO
A
O08V
A-1
SR
2 S
l.5
IN2
Clien
tL
ine
I08T
G10
SR
2 S
l2
Rx
Tx
OU
T2
VO
A
O08
VA
-1S
R2
Sl.
5C
lien
tL
ine
I01
T10
GS
R2
S
l1
0
Rx
Tx
IN3
VO
AO
UT
3
1211
Fig. 198 Kamenz SR1&2
TIP Discuss in class the obtained results.
Hardware & Functionality
FT22124EN03GLA0
© 2011 Nokia Siemens Networks 206
I’ve got it !
F I N I S H .F I N I S H .
Fig. 199