harmonisation working group cer offices, tallaght 20 october 2009 retail market harmonisation...
DESCRIPTION
Harmonisation Working Group Matters Arising HWG Meeting Schedule Additional provisional meetings on 11 th and 27 th November 3 Private and ConfidentialTRANSCRIPT
Harmonisation Working Group
CER Offices, Tallaght
20 October 2009
Retail Market Harmonisation Working Group
Harmonisation Working Group
Agenda
Matters Arising from 6th October Presentation of Proposals and Issues
GeneralRegistrationSupplier Unit ChangesObjection & CancellationDe-Registration
Any Other Business Next Meeting
2 Private and Confidential
Harmonisation Working Group
Matters Arising
HWG Meeting ScheduleAdditional provisional meetings on 11th and 27th November
3 Private and Confidential
Harmonisation Working Group
Comments on Todays Proposals
To be forwarded [email protected]@[email protected]
By c.o.p. Tuesday October 27th 2009
4 Private and Confidential
Harmonisation Working Group
General Issues Message Header – Additional Supplier ID removed
No longer send message on behalf of another Supplier Supplier ID values remain different in NI; RoI
Harmonisation would create major data migration challenge MPRN Address Processing
NIE will adopt county codes with English/Gaelic equivalents for RoI counties and separate codes for Derry/Londonderry
Postcode will remain in NIE address validation Other Common Data Segments
Consistent formats adopted Rejection Reason Codes
Where the same rejection reason occurs in both markets, then the same rejection reason code, based on RoI usage, will be used
5 Private and Confidential
Harmonisation Working Group
MPRN Address
Republic of Ireland Northern IrelandField Use Chars Pattern Value Use Field Use Chars Pattern Value CommentsUnitNo opt 10 yes no req UnitNo opt 10 yes noAddrLine1 opt 40 yes no AddrLine1 opt 40 yes noAddrLine2 opt 40 yes no AddrLine2 opt 40 yes noHouseNo opt 10 yes no HouseNo opt 10 yes noStreet opt 60 yes no Street opt 60 yes noAddrLine4 opt 40 yes no AddrLine4 opt 40 yes noAddrLine5 opt 40 yes no AddrLine5 opt 40 yes noPostCode opt 10 yes no PostCode opt 10 yes noCity opt 40 yes no City opt 40 yes noCountyIreland opt 3V no yes CountyIreland opt 3V no yes NIE to align with ESB + add new codes for Londonderry/DerryCountry opt 3 no yes Country opt 3 no yes
Harmonisation Working Group
Customer Name
Republic of Ireland Northern IrelandField Use Chars Pattern Value Use Field Use Chars Pattern Value CommentsTitle opt 4V yes yes req Title opt 4V yes yes ESB retain cross field validation on this segment, e.g.
FirstName/OrganisationOneLastName opt 40 yes no LastName opt 40 yes noFirstName opt 40 yes no FirstName opt 40 yes noOrganisationOne opt 40 yes no OrganisationOne opt 40 yes noOrganisationTwo opt 40 yes no OrganisationTwo opt 40 yes noRegisteredCompanyNumber opt 30 yes no RegisteredCompanyNumber opt 30 yes noTradingAs opt 40 yes no TradingAs opt 40 yes no
Harmonisation Working Group
Customer Contact Details
Republic of Ireland Northern IrelandField Use Chars Pattern Value Use Field Use Chars Pattern ValueEmail opt 70V no no opt Email opt 70V no noPhoneOne - Number opt 20 no no opt PhoneOne - Number opt 20 no noPhoneOne - Extn opt 10 no no PhoneOne - Extn opt 10 no noPhoneTwo - Number opt 20 no no PhoneTwo - Number opt 20 no noPhoneTwo - Extn opt 10 no no PhoneTwo - Extn opt 10 no noFax - Number opt 20 no no Fax - Number opt 20 no noFax - Extn opt 10 no no Fax - Extn opt 10 no no
Harmonisation Working Group
Notification Address
Republic of Ireland Northern IrelandField Use Chars Pattern Value Use Field Use Chars Pattern Value
optCOName opt 40 yes no opt COName opt 40 yes noUnitNo opt 10 yes no UnitNo opt 10 yes noAddrLine1 opt 40 yes no AddrLine1 opt 40 yes noAddrLine2 opt 40 yes no AddrLine2 opt 40 yes noHouseNo opt 10 yes no HouseNo opt 10 yes noStreet req 60 yes no Street req 60 yes noAddrLine4 opt 40 yes no AddrLine4 opt 40 yes noAddrLine5 opt 40 yes no AddrLine5 opt 40 yes noPostCode opt 10 no no PostCode opt 10 no noCity opt 40 yes no City opt 40 yes noCountyIreland opt 3V no yes CountyIreland opt 3V no yesCountyState opt 40 yes no CountyState opt 40 yes noCountry opt 3V no yes Country opt 3V no yes
POBoxNumber req 10 no no opt POBoxNumber req 10 no noPostCode opt 10 no no PostCode opt 10 no noCity opt 40 yes no City opt 40 yes noCountry opt 3V no yes Country opt 3V no yes
NotificationAddressStreetAddressType
ORPostBox
Harmonisation Working Group
Technical Contact
Republic of Ireland Northern IrelandSegment Use Field Use Chars Pattern Value Use Field Use Chars Pattern ValueTechnicalContact opt ContactName opt 40 yes no opt ContactName opt 40 yes no
TechnicalContactType opt Email opt 70V no no opt Email opt 70V no noContactDetailsType opt PhoneOne - Number opt 20 no no opt PhoneOne - Number opt 20 no no
PhoneOne - Extn opt 10 no no PhoneOne - Extn opt 10 no noPhoneTwo - Number opt 20 no no PhoneTwo - Number opt 20 no noPhoneTwo - Extn opt 10 no no PhoneTwo - Extn opt 10 no noFax - Number opt 20 no no Fax - Number opt 20 no noFax - Extn opt 10 no no Fax - Extn opt 10 no no
StreetAddressType opt COName opt 40 yes no opt COName opt 40 yes noUnitNo opt 10 yes no UnitNo opt 10 yes noAddrLine1 opt 40 yes no AddrLine1 opt 40 yes noAddrLine2 opt 40 yes no AddrLine2 opt 40 yes noHouseNo opt 10 yes no HouseNo opt 10 yes noStreet req 60 yes no Street req 60 yes noAddrLine4 opt 40 yes no AddrLine4 opt 40 yes noAddrLine5 opt 40 yes no AddrLine5 opt 40 yes noPostCode opt 10 no no PostCode opt 10 no noCity opt 40 yes no City opt 40 yes noCountyIreland opt 3V no yes CountyIreland opt 3V no yesCountyState opt 40 yes no CountyState opt 40 yes noCountry opt 3 no yes Country opt 3 no yes
Harmonisation Working Group
Registration message use
Registration messages to be aligned between RoI and NI Introduce message 102 to confirm CoS acceptance Message 102P will always be sent if site visit, energisation or
connection agreement required Message 140 to be included in schema but will not be used in RoI Message 010 no longer used for change of Supplier Unit
Replaced by 015, 115, 115R
11 Private and Confidential
Harmonisation Working Group
MPRN Web Site NIE will provide MPRN look-ups for new connections and for connected meter points (metered and unmetered) Equivalent data will be provided by NIE with the following exceptions
Non domestic customer name is not proposed – pending DP reviewMedical and special needs data is not proposed – pending DP review
• Customer permission required for medical flag in RoIMeter location, category and register digits/type are not providedMeter configuration is not provided for new connectionsBilling address and not meter point address for unmetered sites
Load profile and meter multiplier will be provided NIE do not propose to provide through the MPRN web-site:
Market message lookups –managed through the messaging solutionDownload of full list of eligible HH sites (QH is provided in RoI)
NIE need to review provision of address search with NIAUR and Consumer Council – concerns exist on erroneous registrations
12 Private and Confidential
Harmonisation Working Group
Registration Request 010 MPRN LevelMessage 010 RoI Message N010 NIField Use Chars Pattern Value Use Field Use Chars Pattern Value Comments
MPRN req 11 no no MPRN req 11 no no Region specific ranges continueMPBusinessReference req 35 no no MPBusinessReference req 35 no no Becomes mandatory in NISupplierMPID req 3 no no SupplierMPID req 3 no no No alignment of data values SupplierUnitID req 9F yes no SupplierUnitID req 9F yes no
SSAC req 1 yes no SSAC req 1 yes noRetain for future use. 'A' for independent suppliers and 'F' otherwise.
SupplyAgreementFlag req none no no SupplyAgreementFlag req none no no
COT_LE_Flag req none no no COT_LE_Flag req none no noIf this flag is not set and CoT/CoLE, ESB infer change whilst NIE will reject.
GenerationUnitAggregationCode MissingCOS_ReadArrangementCode opt 3 no yes COS_ReadArrangementCode opt 3 no yes ESB to add a new 'DR' (supplier of last resort)
COS_EstimateAcceptableFlag opt none no no COS_EstimateAcceptableFlag opt none no noInfer 'N' if no actual read have happened in last 12 months.
MeterConfigurationCode opt 10V no yes MeterConfigurationCode opt 10V no yes Different rules for QH eligibility - leave "as is" TariffConfigurationCode opt 2F yes no TariffConfigurationCode opt 2F yes no Used for keypad in NI only
RequiredDate opt RequiredDate optDate range eligibility left "as is" on both sides, for cost reasons and NI "cooling-off" period
UsageType opt 2F no yes UsageType opt 2F no yesNot used by ESB. NIE to make optional and assume no change if not provided
EAI_Code opt 5V no yes EAI_Code opt 5V no yes Regulatory listing remains separateSecurityQuestion opt 2 no yes SecurityQuestion opt 2 no yes Used for keypad in NI onlySecurityAnswer opt 100 no no SecurityAnswer opt 100 no no Used for keypad in NI onlyMeterReaderPassword opt 8 no no MeterReaderPassword opt 8 no no NIE regulatory requirement, used in NI onlyDebtTransferFlag opt none no no DebtTransferFlag opt none no no Used in NI onlyMedicalEquipmentDetailsCode opt 4 no yes MedicalEquipmentDetailsCode opt 4 no yes NIE to adopt ESB approach and merge listsCustomerServiceDetailsCode opt 4V no yes CustomerServiceDetailsCode opt 4V no yes NIE to adopt ESB approach and merge lists
AppointmentId AppointmentIdNIE to consider passing in booked Date/Timeslot in order to align - optionalTo be defined To be defined
Date Date
remove from schema
Harmonisation Working Group
Registration Request 010 CoT History
Republic of Ireland Northern IrelandField Use Chars Pattern Value Use Field Use Chars Pattern ValuePreviousSupplier req 3 no yes opt PreviousSupplier req 3 no yesPreviousAccountNumber opt 20 no no PreviousAccountNumber opt 20 no noPreviousMPRN opt 11 no no PreviousMPRN opt 11 no noPreviousAddress opt none no no PreviousAddress opt none no no
Will be retained in NI for debt tracking, segment optional and not used in RoI
Harmonisation Working Group
Registration Request 010 Meter Readings
Data required to identify registers will differ as NI system does not support register type code
Republic of Ireland Northern IrelandUse Field Use Chars Pattern Value Use Field Use Chars Pattern Value Commentsopt MeterCategoryCode opt 15V no no opt MeterCategoryCode opt 15V no no Not used by NIE
SerialNumber opt 9 no no SerialNumber opt 9 no no Mandatory in NIreq MeterRegisterSequence opt 3 no no req MeterRegisterSequence opt 3 no no
TimeslotCode opt 10V no yes TimeslotCode opt 10V no yes Mandatory in NIReadingValue req 15.3 no no ReadingValue req 15.3 no noRegisterTypeCode opt 2F no yes RegisterTypeCode opt 2F no yes Not used by NIE
Harmonisation Working Group
Registration issues #1 – CoS Estimates
CoS estimates are permitted in RoI Will be permitted in NI when scheduled or customer reads are
requested but are invalid or not available Will not be permitted if there is no read history in last 12 months
16 Private and Confidential
Harmonisation Working Group
Registration issues #2 – Required Date Mandatory for NI CoS when not using a scheduled read
Can be omitted in RoI and interpreted ‘as soon as possible’ Minor differences in rules for specifying required date
Cooling off period for NI domestic customers (see #3 next slide) Operational differences such as fieldwork lead times ESB will infer a required date when it is not provided
Handling of Required Date when a Reading is Obtained In RoI the CoS effective date will be set to the day after the reading date In NI the required date is used provided the reading used is within 4 working days of the required date
Suppliers requested to comment on the following options1. Harmonising on the RoI approach 2. Keeping the current, separate arrangement3. Allowing the NI decision to be driven by lowest implementation cost Depending on NIE systems decisions, options 1 & 2 may incur costs
17 Private and Confidential
Harmonisation Working Group
Registration issues #3 – Cooling Off Period Cooling off period is feature of NI market for domestic customers
Suppliers prefer a single customer contactTo facilitate this, it is proposed for the NI market only
• Required date must be at or after end of Cooling Off Period• Suppliers may provide meter reading on messages 010 or 210• If provided on message 010 at registration
– If Suppliers sets CoS estimate flag on NIE will create estimate based on this read at required date (unless a higher priority read available)
– If CoS estimate flag is not set then can NIE use message 010 read at end of CoP or should message 210 be expected?
• If provided on message 210 following Cooling Off Period– NIE will use message 210 reading to facilitate CoS at read date
Retrospective CoS (at start of CoP) is an alternative possibilityNext slide discusses
18 Private and Confidential
Harmonisation Working Group
Registration issues #3b – Cooling Off Period Retrospective CoS (at start of CoP) requires consideration by Suppliers of three issues:
Processing of scheduled reads occurring within the CoP need to be agreed• If a scheduled read is available can it be used in place of the message 010 read
NIE (and potentially Old Suppliers) would need to suppress or reverse messaging and billing for a period of 10 working days
• Accepting use of scheduled read as the CoS read would eliminate most of these issuesInitial aggregation for settlement will be against the Old Supplier at D+4 until end of cooling off period
(D+10)• Suppliers should consider whether this is acceptable
Retrospective CoS is not possible for keypadCustomer must call in to complete transferKeypad codes cannot be input retrospectively
19 Private and Confidential
Harmonisation Working Group
Registration issues #4 – General Data Usage type
Not used in RoIProposed to remain in NI as Supplier can drive change of DUoS tariffWill become optional: if omitted assume no change
EAI CodeRegulatory requirements require different code sets: NACE - SIC
Medical Equipment and Customer Special Needs codesSchema harmonised (single entry) but codes remain differentAdditional codes should be added using message 013
Appointment IDField is not used in RoIRepresents a confirmed appointment in NI
(even if date subsequently changes)
20 Private and Confidential
Harmonisation Working Group
Registration issues #5 – Meter Data and Changes Serial Number and Timeslot Proposals in NI
Serial number is required in NI to protect against wrong meter in communal blocks.
• In RoI meter category may be provided as an alternativeTimeslot is mandatory in NI as systems do not support register type
• In RoI register type or sequence number may be provided as an alternative
Change to Interval MeteringNIE allow a change to (or from if <70kVA) HH metering as part of a CoS
request. Change to QH metering is not proposed to be allowed in RoI.
21 Private and Confidential
Harmonisation Working Group
New Connection Registration
New Connection EnergisationRegistration is required for energisation of an NI domestic customerRegistration is not required for energisation of an RoI domestic customerNIE propose to retain enduring solution rule because:
• Operational efficiency arises from meter installation as per Supplier request • Enables Suppliers to establish customer contract• Safeguards in place for customers requiring in emergency connection
Registrations can be superceded prior to energisationNIE will implement equivalent process up to fieldwork despatch similar to the
current ESB process
22 Private and Confidential
Harmonisation Working Group
Registration Response Issues Issues variously impacting messages 101, 101P, 102, 102P and 105 Load Profile, Load Factor, Transformer Loss Factor
Load Profile populated where available (may not be available for 101P and 102P in NI as dependent on meter installation)
Load Factor not applicable in NI if NHH SToD metering discontinuedTransformer Loss Factor not applicable in NI
Customer ContactWill be included on 101P and 102P in both NI and RoI
Effective From Date on message 101P to be removed Read Cycle Code
Code cross refers to a date calendar in both NI and RoIConstructed using a day number in RoI … e.g. cycle day 40Constructed using a week & day number in NI…e.g. week 08 day 5
Rejection reason codes to be aligned to ensure the same code means the same thing
23 Private and Confidential
Harmonisation Working Group
N/C Registration Response Message 101PRepublic of Ireland Northern Ireland
Use Field Use Chars Pattern Value Use Field Use Chars Pattern Value
MPRN req 11 no no MPRN req 11 no noMPBusinessReference req 35 no no MPBusinessReference req 35 no noMeterPointStatusCode req 2V no yes MeterPointStatusCode req 2V no yesSupplierMPID opt 3 no no SupplierMPID opt 3 no yesSupplierUnitID req 9F yes no SupplierUnitID req 9F yes noSSAC req 1 yes no SSAC req 1 yes noSettlementClassCode req 1 no yes SettlementClassCode req 1 no yesConnectionSystemCode req 10 no yes ConnectionSystemCode req 10 no yesDUOS_Group req 4V no yes DUOS_Group req 4V no yesMaximumImportCapacity opt 9 no no MaximumImportCapacity opt 9 no noMeterConfigurationCode opt 10V no yes MeterConfigurationCode opt 10V no yesLoadFactorCode opt 10 no yes LoadFactorCode opt 10 no yes Not applicable in NIDLF_Code req 5 no no DLF_Code req 5 no noTransformerLossFactor opt 6,4 no no TransformerLossFactor opt 6,4 no no Not applicable in NICOT_LE_Flag req COT_LE_Flag reqUnmeteredDetails MissingGenerationUnitID MissingGenerationUnitAggregationCode GenerationUnitAggregationCodeMaximumExportCapacity opt 9 no no MaximumExportCapacity opt 9 no noRegistrationReceiptDate req RegistrationReceiptDate reqLoadProfileCode opt 3 no yes LoadProfileCode opt 3 no yesEffectiveFromDate EffectiveFromDate Never used on 101P
ReadScheduleDetailsReadFrequencyCode opt 3 no yes ReadFrequencyCode opt 3 no yesReadCycle opt 3 no no ReadCycle opt 3 no no Read cycle codes are not aligned
reqM ProvAccCompletionRequirementCodereq 3F no yes reqM ProvAccCompletionRequirementCodereq 3F no yesCodes to be harmonised, CoP redundant
remove from schema remove from schema
Comments
remove from schema remove from schemaremove from schema remove from schema
remove from schema remove from schema
Harmonisation Working Group
N/C Registration Response Message 101Republic of Ireland Northern IrelandField Use Chars Pattern Value Use Field Use Chars Pattern Value Comments
MPRN req 11 no no MPRN req 11 no noMPBusinessReference opt 35 no no MPBusinessReference opt 35 no noMeterPointStatusCode req 2V no yes MeterPointStatusCode req 2V no yesSupplierMPID opt 3 no no SupplierMPID opt 3 no noSupplierUnitID req 9F yes no SupplierUnitID req 9F yes noSSAC req 1 yes no SSAC req 1 yes noSettlementClassCode req 1 no yes SettlementClassCode req 1 no yesConnectionSystemCode req 10 no yes ConnectionSystemCode req 10 no yesDUOS_Group req 4V no yes DUOS_Group req 4V no yesMaximumImportCapacity opt 9 no no MaximumImportCapacity opt 9 no noMeterConfigurationCode opt 10V no yes MeterConfigurationCode opt 10V no yesLoadFactorCode opt 10 no yes LoadFactorCode opt 10 no yes Not applicable in NIDLF_Code req 5 no no DLF_Code req 5 no noTransformerLossFactor opt 6,4 no no TransformerLossFactor opt 6,4 no no Not applicable in NICOT_LE_Flag req COT_LE_Flag reqMedicalEquipmentDetailsCode opt 4 no yes MedicalEquipmentDetailsCode opt 4 no yes NIE to adopt ESB approach and merge listsCustomerServiceDetailsCode opt 4V no yes CustomerServiceDetailsCode opt 4V no yes NIE to adopt ESB approach and merge listsUnmeteredDetails MissingGenerationUnitID MissingGenerationUnitAggregationCode GenerationUnitAggregationCodeMaximumExportCapacity opt 9 no no MaximumExportCapacity opt 9 no noRegistrationReceiptDate req RegistrationReceiptDate reqLoadProfileCode opt 3 no yes LoadProfileCode opt 3 no yesEffectiveFromDate opt EffectiveFromDate optKeypadPremiseNumber opt 19F yes no KeypadPremiseNumber opt 19F yes no
ReadScheduleDetailsReadFrequencyCode opt 3 no yes ReadFrequencyCode opt 3 no yesReadCycle opt 3 no no ReadCycle opt 3 no no Read cycle codes are not aligned
remove from schema remove from schema
remove from schema remove from schemaremove from schema remove from schema
Harmonisation Working Group
N/C Registration Response Message 101R
Republic of Ireland Northern IrelandUse Field Use Chars Pattern Value Use Field Use Chars Pattern Value
MPRN req 11 no no MPRN req 11 no noMPBusinessReference req 35 no no MPBusinessReference req 35 no noSupplierUnitID opt 9F yes no SupplierUnitID opt 9F yes noSSAC opt 1 yes no SSAC opt 1 yes noSupplyAgreementFlag opt SupplyAgreementFlag optGenerationUnitID MissingGenerationUnitAggregationCode MissingRegistrationReceiptDate req RegistrationReceiptDate req
reqM RejectReasonCode req 2-3 no yes reqM RejectReasonCode req 2-3 no yes NIE/ESB to harmonise codes
remove from schema remove from schema
Comments
remove from schema remove from schema
Harmonisation Working Group
CoS Registration Response Message 102PRepublic of Ireland Northern Ireland
Use Field Use Chars Pattern Value Use Field Use Chars Pattern Value
MPRN req 11 no no MPRN req 11 no noMPBusinessReference req 35 no no MPBusinessReference req 35 no noMeterPointStatusCode req 2V no yes MeterPointStatusCode req 2V no yesSupplierUnitID req 9F yes no SupplierUnitID req 9F yes noSSAC req 1 yes no SSAC req 1 yes noSettlementClassCode req 1 no yes SettlementClassCode req 1 no yesConnectionSystemCode req 10 no yes ConnectionSystemCode req 10 no yesDUOS_Group req 4V no yes DUOS_Group req 4V no yesMaximumImportCapacity opt 9 no no MaximumImportCapacity opt 9 no noLoadProfileCode opt 3 no yes LoadProfileCode opt 3 no yesLoadFactorCode opt 10 no yes LoadFactorCode opt 10 no yes Not applicable in NIMeterConfigurationCode opt 10V no yes MeterConfigurationCode opt 10V no yesDLF_Code opt 5 no no DLF_Code opt 5 no noTransformerLossFactor opt 6,4 no no TransformerLossFactor opt 6,4 no no Not applicable in NICOT_LE_Flag req COT_LE_Flag reqUnmeteredDetails MissingGenerationUnitID MissingGenerationUnitAggregationCode GenerationUnitAggregationCodeMaximumExportCapacity opt 9 no no MaximumExportCapacity opt 9 no noCOS_ReadArrangementCode opt 3 no yes COS_ReadArrangementCode opt 3 no yesRegistrationMeterConfigurationCodeopt 10V no yes RegistrationMeterConfigurationCodeopt 10V no yesCOS_EstimateAcceptableFlag opt COS_EstimateAcceptableFlag optReadReasonCode opt 2 no yes ReadReasonCode opt 2 no yesRequiredDate opt RequiredDate optRegistrationReceiptDate req RegistrationReceiptDate reqLastActualReadDate opt LastActualReadDate opt
ReadScheduleDetailsReadFrequencyCode opt 3 no yes ReadFrequencyCode opt 3 no yesReadCycle opt 3 no no ReadCycle opt 3 no no Read cycle codes are not aligned
reqMProvAccCompletionRequirementCodereq 3 no yes reqM ProvAccCompletionRequirementCodereq 3 no yes
Comments
remove from schema remove from schemaremove from schema remove from schema
remove from schema remove from schema
Harmonisation Working Group
CoS Registration Response Message 102Republic of IrelandField Use Chars Pattern Value
MPRN req 11 no noMPBusinessReference req 35 no noMeterPointStatusCode req 2V no yesSupplierUnitID req 9F yes noSSAC req 1 yes noSettlementClassCode req 1 no yesConnectionSystemCode req 10 no yesDUOS_Group req 4V no yesMaximumImportCapacity req 9 no noLoadProfileCode opt 3 no yesLoadFactorCode opt 10 no yes Not applicable in NIMeterConfigurationCode opt 10V no yesDLF_Code req 5 no noTransformerLossFactor opt 6,4 no no Not applicable in NICOT_LE_Flag reqUnmeteredDetailsGenerationUnitIDGenerationUnitAggregationCodeMaximumExportCapacity opt 9 no noReadFrequencyCode opt 3 no yesReadCycle opt 3 no no Read cycle codes are not alignedCOS_ReadArrangementCode opt 3 no yesRegistrationMeterConfigurationCodeopt 10 no yesCOS_EstimateAcceptableFlag optReadReasonCode opt 2 no yesRequiredDate optRegistrationReceiptDate reqLastActualReadDate opt
ESB to introduce a new field to indicate that SpecialNeeds has been removed
remove from schema
remove from schemaremove from schema
Harmonisation Working Group
CoS Registration Response Message 102R
Republic of Ireland Northern IrelandUse Field Use Chars Pattern Value Use Field Use Chars Pattern Value
MPRN req 11 no no MPRN req 11 no noMPBusinessReference req 35 no no MPBusinessReference req 35 no noSupplierUnitID opt 9F yes no SupplierUnitID opt 9F yes noSSAC opt 1 yes no SSAC opt 1 yes noSupplyAgreementFlag opt none no no SupplyAgreementFlag opt none no noGenerationUnitID MissingGenerationUnitAggregationCode MissingCOS_ReadArrangementCode opt 3 no yes COS_ReadArrangementCode opt 3 no yesCOS_EstimateAcceptableFlag opt none no no COS_EstimateAcceptableFlag opt none no noMeterConfigurationCode opt 10V no yes MeterConfigurationCode opt 10V no yesRequiredDate opt RequiredDate optRegistrationReceiptDate req RegistrationReceiptDate req
EffectiveFromDate opt EffectiveFromDate optUse to show last CoS date when reject reason = CoS
reqMRejectReasonCode req 2-3 no yes reqMRejectReasonCode req 2-3 no yes NIE/ESB to harmonise codes
remove from schema
Comments
Date Date
Date Date
remove from schema remove from schema
Date Date
remove from schema
Harmonisation Working Group
Notification of CoS 110
Republic of Ireland Northern IrelandField Use Chars Pattern Value Use Field Use Chars Pattern Value
MPRN req 11 no no MPRN req 11 no noCOT_LE_Flag req no no COT_LE_Flag req no noCOS_ReadArrangementCode opt 3 no yes COS_ReadArrangementCode opt 3 no yesRegistrationReceiptDate req RegistrationReceiptDate reqRequiredDate opt RequiredDate optOldKeypadPremiseNumber opt 19F yes no OldKeypadPremiseNumber opt 19F yes noIssue_Date req Issue_Date reqDebtTransferFlag opt DebtTransferFlag opt
Harmonisation Working Group
CoS Confirmation Issues
Old and New Supplier ID In NI the identification of old supplier is provided to new
supplier on N105 In NI the identification of new supplier is provided to old
supplier on N105L The data provision is to facilitate debt transfer and contact
processing and is not applicable in the RoI This arrangement is proposed to continue
Harmonisation Working Group
CoS Confirmation 105Republic of Ireland Northern Ireland
Use Field Use Chars Pattern Value Use Field Use Chars Pattern Value Comments
MPRN req 11 no no MPRN req 11 no noMPBusinessReference opt 35 no no MPBusinessReference opt 35 no noMeterPointStatusCode req 2V no yes MeterPointStatusCode req 2V no yesSupplierMPID req 3 no no SupplierMPID req 3 no noSupplierUnitID req 9F yes no SupplierUnitID req 9F yes noSSAC req 1 yes no SSAC req 1 yes noSettlementClassCode req 1 no yes SettlementClassCode req 1 no yesConnectionSystemCode req 10 no yes ConnectionSystemCode req 10 no yesDUOS_Group req 4V no yes DUOS_Group req 4V no yesMaximumImportCapacity opt 9 no no MaximumImportCapacity opt 9 no noMICStartDate opt MICStartDate opt Not applicable in RoICurrentChargeableServiceCapacityopt 9 no no CurrentChargeableServiceCapacity opt 9 no no Not applicable in RoIMeterConfigurationCode opt 10V no yes MeterConfigurationCode opt 10V no yesLoadFactorCode opt 10 no yes LoadFactorCode opt 10 no yes Not applicable in NIDLF_Code req 5V no no DLF_Code req 5 no noTransformerLossFactor opt 6.4 no no TransformerLossFactor opt 6.4 no no Not applicable in NIUnmeteredDetails MissingMedicalEquipmentDetailsCode opt 4 no yes MedicalEquipmentDetailsCode opt 4 no yes NIE to adopt ESB approach and merge listsCustomerServiceDetailsCode opt 4V no yes CustomerServiceDetailsCode opt 4V no yes NIE to adopt ESB approach and merge listsGenerationUnitID MissingGenerationUnitAggregationCode GenerationUnitAggregationCodeMaximumExportCapacity opt 9 no no MaximumExportCapacity opt 9 no noEffectiveFromDate req EffectiveFromDate reqSupplierMPIDOld opt 3 no no SupplierMPIDOld opt 3 no no Used in NI for debt transfer / contactKeypadPremiseNumber opt 19F yes no KeypadPremiseNumber opt 19F yes no
ReadScheduleDetailsopt ReadFrequencyCode opt 3 no yes opt ReadFrequencyCode opt 3 no yes
ReadCycle opt 3 no no ReadCycle opt 3 no no Read cycle codes are not aligned
remove from schema remove from schema
Date Date
remove from schema remove from schema
remove from schema remove from schema
Date Date
Harmonisation Working Group
CoS Loss Confirmation 105L
Republic of Ireland Northern IrelandField Use Chars Pattern Value Use Field Use Chars Pattern Value
MPRN req 11 no no MPRN req 11 no noSupplierMPID opt 3 no no SupplierMPID opt 3 no no Used in NI for debt transfer / contactOldKeypadPremiseNumber opt 19F yes no OldKeypadPremiseNumber opt 19F yes noEffectiveFromDate req EffectiveFromDate req
Comments
Date Date
Harmonisation Working Group
Change of Supplier Unit
NIE to introduce messages 015, 115, 115R (replacing N010, N195)Message design as per RoIProcessing rules as in RoI
34 Private and Confidential
Harmonisation Working Group
Change of Supplier Unit MessagesMarket Message: ChangeOfSSACandorSupplierUnit (015)Segment Use Field Use Chars Pattern Value Comments
Top Level MPRN req 11 no noMPBusinessReference req 35 no noSupplierMPID req 3 no noSupplierUnitID req 9F yes noSSAC req 1 yes noRequiredDate req Can't be in past and can't be greater than 10 days in futureDate
Market Message: ChangeofSSACandorSupplierUnitConfirmation (115)Segment Use Field Use Chars Pattern Value
Top Level MPRN req 11 no noMPBusinessReference req 35 no noSupplierUnitID req 9F yes noSSAC req 1 yes noEffectiveFromDate req Date
Market Message: Change of SSAC and or Supplier Unit Rejection (115R)
Segment Use Field Use Chars Pattern Value
Top Level MPRN req 11 no noMPBusinessReference req 35 no noSupplierUnitID req 9F yes noSSAC req 1 yes noRequiredDate req
RejectionDetails req RejectReasonCode req 2-3 no yes
Date
Harmonisation Working Group
Objection Issues Objection for Debt and Contract
Permitted in Northern Ireland for non-domesticNot permitted in Republic of Ireland
Debt Contact NoticeMay be raised by Old Supplier in Northern Ireland only (message 012)
ET ObjectionsNot allowed in RoI for QH sitesTimeline is 65 days in RoI and 100 days in NI due to read cycle
Rules for Suspending Completion and Fieldwork are DifferentESB suspend completion for 10 daysNIE propose to suspend completion and associated fieldwork for 10 days for ET objections before
completionIn NIE fieldwork is currently cancelled for debt or contract objections – but not for debt contact
36 Private and Confidential
Harmonisation Working Group
Objection Messages 012 & 112Republic of Ireland 012 Northern Ireland N012
Use Field Use Chars Pattern Value Use Field Use Chars Pattern Value Comments
MPRN req 11 no no MPRN req 11 no noMPBusinessReference req 35 no no MPBusinessReference req 35 no noSupplierMPID req 3 no no SupplierMPID req 3 no noRequestStatusCode req 3V no yes RequestStatusCode req 3V no yesObjectionReasonCode req 3 no yes ObjectionReasonCode req 3 no yes Additional codes in NI
Republic of Ireland 112 Northern Ireland N112Use Field Use Chars Pattern Value Use Field Use Chars Pattern Value Comments
MPRN req 11 no no MPRN req 11 no noSupplierMPID req 3 no no SupplierMPID req 3 no noObjectionReasonCode req 3 no yes ObjectionReasonCode req 3 no yes Additional codes in NIRequestStatusCode req 3V no yes RequestStatusCode req 3V no yesObjectionDate req ObjectionDate req
Harmonisation Working Group
Objection Message 112R
Republic of Ireland 112R Northern Ireland N112RUse Field Use Chars Pattern Value Use Field Use Chars Pattern Value Comments
MPRN req 11 no no MPRN req 11 no noMPBusinessReference req 35 no no MPBusinessReference req 35 no noObjectionReasonCode req 3 no yes ObjectionReasonCode req 3 no yes Additional codes in NIRequestStatusCode req 3V no yes RequestStatusCode req 3V no yesObjectionDate req ObjectionDate req
reqM RejectReasonCode req 2-3 no yes reqM RejectReasonCode req 2-3 no yes
Harmonisation Working Group
Objection Messages 012W & 112W
Republic of Ireland 112W Northern Ireland N112WUse Field Use Chars Pattern Value Use Field Use Chars Pattern Value Comments
MPRN req 11 no no MPRN req 11 no noSupplierMPID req 3 no no SupplierMPID req 3 no noObjectionReasonCode req 3 no yes ObjectionReasonCode req 3 no yes Additional codes in NIRequestStatusCode req 3V no yes RequestStatusCode req 3V no yesObjectionDate req ObjectionDate req
Republic of Ireland 012W Northern Ireland N012WUse Field Use Chars Pattern Value Use Field Use Chars Pattern Value Comments
MPRN req 11 no no MPRN req TBC11 no noMPBusinessReference req 35 no no MPBusinessReference req 35 no noRequestStatusCode req 3V no yes RequestStatusCode req TBC3V no yesObjectionReasonCode req 3 no yes ObjectionReasonCode req TBC3 no yes Additional codes in NISupplierMPID req 3 no no SupplierMPID req 3 no no
Harmonisation Working Group
Cancellation
Cancellation reasons to be extended to include RoI values NIE will implement RoI process that a new supplier can cancel a
CoS following completion for any reasonThere will not need to be an outstanding objectionOld Supplier must agree using message 011ACut off in NI will be 100 days (65 days in RoI)Will not apply to keypadIn NI this is currently only allowed when there is an ET objection
40 Private and Confidential
Harmonisation Working Group
Cancellation Issues Rules for Automated Cancellation proposed to be slightly different
Applies to non-completed CoSRoI
• 20 days after a scheduled read; or• 40 days after CR required date; or• 40 days from registration acceptance unless there is outstanding fieldwork
NI • 20 days after a scheduled read; or• 40 days from required date unless there is outstanding fieldwork NIE insist on a required
date if not scheduled read.NIE will cancel if it apparent that fieldwork cannot be completed (e.g. for reasons of safety or
customer failure).
41 Private and Confidential
Harmonisation Working Group
Cancellation Messages 011, 111, 111LRepublic of Ireland 011 Northern Ireland N011
Use Field Use Chars Pattern Value Use Field Use Chars Pattern Value Comments
MPRN req 11 no no MPRN req 11 no noMPBusinessReference req 35 no no MPBusinessReference req 35 no noCancellationReasonCode req 2 no yes CancellationReasonCode req 2 no yesSupplierMPID req 3 no no SupplierMPID req 3 no no
Republic of Ireland 111 Northern Ireland N111Use Field Use Chars Pattern Value Use Field Use Chars Pattern Value Comments
MPRN req 11 no no MPRN req 11 no noMPBusinessReference opt 35 no no MPBusinessReference opt 35 no noSupplierMPID opt 3 no no SupplierMPID opt 3 no noCancellationReasonCode req 2 no yes CancellationReasonCode req 2 no yes
EffectiveFromDate opt EffectiveFromDate opt
Set to date of receipt by ESB of 011 when CoS not complete
Republic of Ireland 111L Northern Ireland N111LUse Field Use Chars Pattern Value Use Field Use Chars Pattern Value Comments
MPRN req 11 no no MPRN req 11 no noSupplierMPID req 3 no no SupplierMPID req 3 no noCancellationReasonCode req 2 no yes CancellationReasonCode req 2 no yes
EffectiveFromDate opt EffectiveFromDate opt
Set to date of receipt by ESB of 011 when CoS not complete
Harmonisation Working Group
Cancellation Messages 111R
Republic of Ireland 111R Northern Ireland N111RUse Field Use Chars Pattern Value Use Field Use Chars Pattern Value
MPRN req 11 no no MPRN req 11 no noMPBusinessReference req 35 no no MPBusinessReference req 35 no noCancellationReasonCode req 2 no yes CancellationReasonCode req 2 no yes
reqM RejectReasonCode req 2-3 no yes reqM RejectReasonCode req 2-3 no yes
Harmonisation Working Group
Cancellation Messages 011A, 111A
Republic of Ireland 011A Northern Ireland N011AUse Field Use Chars Pattern Value Use Field Use Chars Pattern Value
MPRN req 11 no no MPRN req 11 no noMPBusinessReference req 35 no no MPBusinessReference req 35 no noCancellationAgreementFlag req none no no CancellationAgreementFlag req none no noSupplierMPID req 3 no no SupplierMPID req 3 no no
Republic of Ireland 111A Northern Ireland N111AUse Field Use Chars Pattern Value Use Field Use Chars Pattern Value
MPRN req 11 no no MPRN req 11 no noCancellationReasonCode req 2 no yes CancellationReasonCode req 2 no yesEffectiveFromDate req EffectiveFromDate req
Harmonisation Working Group
De-Registration Issues Suppliers must request de-registration in RoI using message 021
DUoS standing/capacity charges apply to de-energised sites in RoIDeregistration terminates DUoS chargesPRM de-registration leads to termination of MPRN
• No re-registration is possibleCUS de-registration leads to MPRN remaining de-energised
• Re-registration and energisation is possible through submitting 010ESB also monitor de-energised sites > 2yrs and may invite de-registration
Suppliers cannot currently request de-registration in NINo DUoS charges apply to de-energised sites in NINIE currently handle disconnections for site demolition etc. and issue N122 to terminate registration and inform SupplierSame incentives to de-registration may not currently exist in NI
NIE require additional time to consider implications for revenue protection, re-registration and connections processes
45 Private and Confidential
Harmonisation Working Group
Any Other Business
46 Private and Confidential
Harmonisation Working Group
Next Meeting
Monday November 2nd, 11am to 3pmAt NIAUR offices, Queen Street, BelfastClarification of Supplier Registration CommentsPresentation of Fieldwork
Wednesday November 11th, 12am to 4pmAt NIAUR offices, Queen Street, BelfastProposal Agreement on Registration
47 Private and Confidential