heat pump leaflet astral mar 2012 gh -...

2
2012 No . 120322-02 . Astral Air Source Heat Pumps for Swimming Pools All rights reserved Harald Einevoll All rights reserved Harald Einevoll

Upload: lehuong

Post on 16-Jun-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Heat Pump Leaflet Astral Mar 2012 GH - Astralpoolpdbdocs.astralpool.com/fichasTecnicas/FT03_AC6P_ACWotech... · 2016-02-02 · Air Source Heat Pumps for Swimming Pools A l l r i g

2012

No . 120322-02

.

Astral

Air Source Heat Pumps

for Swimming Pools

All

rig

hts

re

se

rve

d H

ara

ld E

ine

vo

llA

ll ri

gh

ts r

ese

rve

d H

ara

ld E

ine

vo

ll

Page 2: Heat Pump Leaflet Astral Mar 2012 GH - Astralpoolpdbdocs.astralpool.com/fichasTecnicas/FT03_AC6P_ACWotech... · 2016-02-02 · Air Source Heat Pumps for Swimming Pools A l l r i g

Display Controller & Manometer

2 3

TestingEnthalpy-difference Lab.

WHY CHOOSE AN ASTRAL HEAT PUMP?

1. Astral heat pumps are specifically designed for the climate in which they will be used, ensuring maximum energy gain at low air temperatures (higher COP at lower air temperatures, when maximum energy is needed)

4. Value: best prices on the market for the performance and quality you get: We have many years of experience in efficient production, long-lasting relationships with suppliers of quality components and low-cost distribution system.

2. Higher COP - Higher energy gain - Less energy costs. Astral Heat Pumps have oversized Evaporators, Double Titanium A1 Coil Heat Exchangers, Pre- charged Defrosting System;

3. Practical functions. Bottom-pan heating to prevent ice-formation around base of unit, waterproof display and control panel

5S Manufacturing Evaporator Heat exchanger

Features:1. Oversized coated energy collector (air coils) - higher COP

2. Titanium class A1 double-coil heat exchanger

3. Active auto-charged defrosting system - higher COP

4. Digital display

5. Waterproof display and control panel

6. Strong ABS casing - no corrosion

7. Bottom heater to prevent ice formation

8. Galvanized bottom plate for horizontal type

9. Horizontal air flow

10. Easy connection to water system

11. Rotary/Scroll compressor

12. Flow switch protection

13. High / low-pressure switch protectionDOUBLE COIL EXCHANGER

Capacity

Measuring conditions

A15 W26

Power Supply

Controller

Heat exchanger

Number of Compressors

Compressor

Number of Fans

Input Power of Fan

Fan Speed

Noise (1 meter)

Water Connection

Water Flow Rate (min-med-max)

Water Pressure Drop

Code AC6

Heating Capacity

Input Power

Running Current

COP

Heating Capacity

Input Power

Running Current

COP

L

W

H

L

W

H

Net Weight

Gross Weight

KW

KW

A

KW/KW

KW

KW

A

KW/KW

V/PH/HZ

W

RPM

dB(A)

inch

m3/h

kpa

mm

mm

mm

mm

mm

mm

kg

kg

380-400V/3P H/50HZ

Scroll

Weight

Net Dimension

Packing Dimension

5.4

1.0

4.3

5.4

3.8

0.9

3.9

4.2

1

1

60

910

50

1-1/2

2.5

10

778

293

511

875

328

545

41

46

AC10 AC13 AC15 AC17 AC20 AC25

9.5

1.7

7.4

5.6

6.4

1.5

6.5

4.3

1

1

80

890

53

1-1/2

4.0

10

938

360

581

1060

380

630

53

59

11.5

2.1

9.1

5.5

7.9

1.9

8.2

4.2

1

1

100

890

54

1-1/2

5.0

12

1015

370

621

1140

400

676

60

67

15.0

2.7

11.7

5.6

9.8

2.4

10.4

4.0

1

1

100

890

54

1-1/2

6.5

12

1015

370

621

1140

400

676

64

71

16.8

3.1

13.5

5.4

11.4

2.8

12.1

4.1

1

1

110

850

56

1-1/2

7.5

14

1080

416

708

1150

450

838

75

83

20.5

3.8

16.5

5.4

14.8

3.6

15.6

4.1

1

1

110

850

56

1-1/2

9.0

14

1080

416

708

1150

450

838

85

93

25.5

4.8

8.5

5.3

18.5

4.6

8.1

4.2

1

1

220

850

56

1-1/2

11.0

16

1078

416

958

1150

475

1088

105

118

30.0

5.4

9.6

5.5

22.1

5.3

9.3

4.2

1

2

440

850

57

1-1/2

13.5

16

1078

416

1258

1150

475

1388

140

152

AC30

220-240V/1P H/50HZ

LED/LCD

Titanium Coil

Function : Heating & cooling with reversible defrosting

AC8

6.8

1.2

5.2

5.6

4.5

1.1

4.7

4.1

1

1

60

910

50

1-1/2

3.2

10

778

293

511

875

328

545

42

47

Rotary

HOW DO HEAT PUMPS WORK?

Astral Heat Pumps Astral Heat Pumps

AC

-Mo

de

l H

ori

zo

nta

l

AC-Model

Astral Heat Pummp Type ACwith R410a refrigerant

Output (kW) at different Air Temp. (Water Temp. 26 )

Output

kW

Air temperature

15

kW

10

kW

5

kW

COP

kW/kW

COP

5

kW/kW

Input

kW

AC-Model

AC6

AC8

AC10

AC13

AC15

AC17

AC20

AC25

AC30

5.4

6.8

9.5

11.5

15.0

16.8

20.5

25.5

30.0

3.8

4.5

6.4

7.9

9.8

11.4

14.8

18.5

22.1

3.0

3.7

5.1

6.7

8.4

9.9

11.7

15.8

18.3

5.4

5.6

5.6

5.5

5.6

5.4

5.4

5.3

5.5

3.0

3.1

3.0

3.2

3.1

3.2

3.1

3.3

3.4

1.2

2.1

3.1

4.8

1.0

1.7

2.7

3.8

5.4

3.5

4.1

5.8

7.2

8.9

10.3

13.5

16.8

20.0