HEAT-TIMER® Save Energy while
improving comfort in Multi Family Buildings
![Page 2: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/2.jpg)
Objectives • Proper control methods for Steam
heat and hot water heat • Basic multiple boiler control options • Using Communication Options to
save energy. Both on direct fuel usage and through information to better maintain equipment.
![Page 3: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/3.jpg)
In heating: What can we control ? • Flow (On Off)
– Steam System: steam temperature (non vacuum) remains relatively constant.
• Control the flow of steam based on outdoor air
• Temperature of heating medium – Hydronic system: Water is easily controllable and
we can do this in numerous ways based on system and boilers being used .
• Vary the water temperature to the radiators based on outdoor air.
![Page 4: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/4.jpg)
Heat-On
Heating SystemSensor (HSS)
Reaches150 Degrees
HSS TemperatureGreater Than
150°F
Heat-Off
HSSTemperatureBegins to Fall
60 Minute Cycle
Heat-Off
Thermal Lockout Active
Heat-On
HSSTemperature
Continues to FallBelow 150°F
HSS Falls Below125 °F
Differential)
EstablishingHeat
EstablishingHeat
Steam Cycle Concept Thermal Lockout and Differential
EXAMPLEHeating System Sensor Adjustment (XYZ) 150°Heating System Sensor Differential -25°Thermal Lockout ONCycle Minutes 60
![Page 5: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/5.jpg)
Hot Water Reset
• Varies the system water temperature based on outdoor air – I.e: Water sent to radiation
increases as it gets colder outside
• Does NOT turn pump off and on
![Page 6: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/6.jpg)
Typical Hot Water Reset Methods
• Direct Single Boiler reset – NOTE: Make sure that boiler can be
operated at lower temperatures – Do not recommend when DHW is
supplied via coil in boiler. • Direct Multiple Boiler reset • 2-way , 3-way or 4-way Motorized
Valve
![Page 7: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/7.jpg)
IMPORTANT Steam to Heat Exchanger
BURNER
HOT WATERDOMESTIC
BOILERSTEAM HEAT EXCHANGER HEATING SYSTEM
SENSORPUMPHEATING LOOP
TO
HEAT-TIMER
HWR
OUTDOORSENSOR
![Page 8: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/8.jpg)
Design Temperature only required on very cold day
![Page 9: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/9.jpg)
Reset Ratio Ranges
![Page 10: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/10.jpg)
Water Temperature Offset W
ater
Tem
pera
ture
(in
°F)
140
130
120
110
100
170
160
150
180
190
200
210
220
E Res
et Rati
o with
0° O
ffset
90
80
Outdoor Temperature (in °F)70 405060 0102030 -10 -20 -30
E Res
et Rati
o with
-20°
Offset
E Res
et Rati
o with
+20°
Offset
![Page 11: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/11.jpg)
Sequencing Controls for Multiple Boilers
• To maximize multiple boiler efficiency you must control them as a team.
A) Not all types of boilers should be controlled in the same fashion.
B) When selecting a control, make sure you know what type of burners you have and not just the number of boilers.
![Page 12: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/12.jpg)
• On/ Of f Bur ner s – Fl ame i s OFF – Fl ame i s ON
• Lo/ Hi Fi r e Bur ner s – Fl ame i s OFF – Fl ame i s Low – Fl ame i s Hi gh
• Al so 3 st age and 4 st age bur ner s
BOILER
OFF BOILER
ON
BOILER
OFF BOILER
Low BOILER
High
On/Off and Lo/Hi Burners
![Page 13: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/13.jpg)
• Full Modulation Burners allow the flame to be adjusted anywhere from low to high fire.
BOILER
OFF BOILER BOILER BOILER
Low BOILER BOILER
High
Full Modulation Burners
![Page 14: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/14.jpg)
TYPICAL CONTROL SYSTEM FOR MULTIPLE FULL MODULATION
BOILERS
Modulating Control
Hi Limit Control
Manual Reset Control
Modulating Controls
![Page 15: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/15.jpg)
Control Of Multiple Full Modulation Boilers with MultiMod
Hi Limit Control
Manual Reset Control
ONE SYSTEMSENSOR
Modulating Control
![Page 16: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/16.jpg)
HI FIRE
LEAD BOILER
Adjustable Modulation Start Point (50 to 100%)
HI FIRE
Boiler # 1
Boiler # 2
Boiler # 3
Modulation Increasing
Modulation Increasing
1 % 50 % 100 %
1 % 50 % 100 % Modulation Increasing
Adjustable Modulation Start Point (50 to 100%)
1 % 50 % 100 %
Typical Sequence of Operation for Higher Mass Boilers w/ Modulating Burners
![Page 17: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/17.jpg)
0
20
40
60
80
100
Boiler # 1Boiler # 2Boiler # 3
As Load is Increasing
Boiler #1 = 40% Boiler # 1 = 20%
Boiler # 2 = 20%
Boiler # 1 = 40%
Boiler # 2 = 40%
Boiler # 1 = 25%
Boiler # 2 = 25%
Boiler # 3 = 15%
Boiler # 1 = 40%
Boiler # 2 = 40%
Boiler # 3 = 40%
Typical Parallel Loading Mode for Lower Mass Condensing Boilers
![Page 18: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/18.jpg)
Using Communication Options to save energy.
Both on direct fuel usage and through information to
better maintain equipment.
![Page 19: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/19.jpg)
Heat-Timer Internet Control Management System (ICMS)
![Page 20: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/20.jpg)
Internet Controls Capabilities Capabilities: Web Based Application.
No On-site server is required No local software is required on personal computer
Wireless Space Sensors allow control to AUTOMATICALLY fine tune heating reset curve based on desired space targets
Alarm E-mail/Text Message capability Can alarm on any monitoring point
Reporting Capability Standard Reports, Custom reports
Additional Sensor Monitoring
![Page 21: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/21.jpg)
Sensor Monitoring Benefits • Space Temperature Inputs (Wired and Wireless)
– Allows the HTC control to fine-tune the reset curves based on space feedback and desired space temperatures.
• Burner Lockout – Alerts management when burner goes into a safety lockout condition
• DHW Temperature Inputs – Alerts management to possible dangerous high temperature DHW
• Boiler DHW Coil Temperature – Alerts management to possible dirty coil
• Oil Tank Monitoring – Alerts management to oil deliveries and consumption
• Oil Filter Monitoring – Alerts management to a dirty oil filter
![Page 22: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/22.jpg)
Additional Sensor Monitoring Benefits • Boiler Feed Water (Water Meter)
– Alerts management to potential boiler damage due to excessive make up water. Either due to numerous blow downs or leaks in piping system.Can assist in monitoring boiler chemical levels
• Boiler Stack Temperature – Alerts management to a dirty boiler which can decrease boiler
operating efficiency • Sump Pump Failure
– Alerts management to a possible flood condition or damaged sump pump
• Conductivity Sensor – Monitor boiler chemical level for both scaling condition or
corrosive condition. • Can monitor alarm outputs from others controls
– I.e.: Heat-Timer snow Melt control in alarm condition.
![Page 23: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/23.jpg)
Alarm Capabilities
All sensors have alarm capability (e-mail or text message)
• The alarm can be sent to multiple people – This provides the capability of immediate notification in
critical situations.
• Less critical or maintenance alarms can be e-mailed to the appropriate personnel – Sample Critical Alarm = Control in bypass, boiler in lockout – Sample Maint. Alarm = High stack sensor
![Page 24: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/24.jpg)
10
9
8
7
6
5
4
3
2
1
MPCNM
T1
T3
T5T5A
SS
SS
SS
SS
T5B
Wireless Space Sensor
Example
10 Story Building
60 Units
10% Rule = 6 Apt Space Sensors
![Page 25: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/25.jpg)
WIRELESS DIAGNOSTICS
Wireless Reception
Space Temps
Battery Indication
![Page 26: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/26.jpg)
BUILDING 3D VIEW
Wireless Paths
![Page 27: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/27.jpg)
Click for Control Settings
Click to View Boiler Room
Click to View Histories
Click to View Alarms
Click to View Sensors
Click to View Over-rides
Click to Set Schedules
SHORTCUTS
![Page 28: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/28.jpg)
Monitor Multiple Building Alarms on One Screen
Buildings in Alarm Condition
![Page 29: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/29.jpg)
MPC PLATINUM (Steam) Cycle Timeline
Vari-Boost
Fast Cool Down
SPACE Lockout
![Page 30: Heat-Timer: Save Energy While Improving Comfort in ... · HSS Temperature Greater Than 150°F Heat-Off HSS Temperature Begins to Fall 60 Minute Cycle Heat-Off Thermal Lockout Active](https://reader034.vdocuments.net/reader034/viewer/2022052019/60339c6a9f0de426b11fc2d2/html5/thumbnails/30.jpg)
HISTORY (Multi-Temp. Sensors)
Outdoor Temp
Space Temps
Heating Sys Sensor