Page 1: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

Heating equipment7

Page 2: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

Heating equipment

Hea

ters

GTG-SHKAF (KSH/TERMO-BOX)

thermo cabinet

p. 304

Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-

480W-T190)

p. 307

Heating plate GTG-PLASTINA2 (RETO-PLATE-

CAVO-150W and RETO-PLATE-CAVO-300W)

p. 309

Heating plate GTG-PLASTINA1

(RETO-PLATE-T190)

p. 311

Heating cable GTG-CABLE1 (RETO-

CORD/S)

p. 313

Plug for heating cable GTG-ZGK (MC-CORD)

p. 316

Plate heater GTG-RADIATOR

(RETO-PLATE-RADIATOR/M)

p. 318

Programmable thermostat GTG-PT (SA-TERMOSTAT-D)

p. 320

Box for heating cable connection GTG-VK2

(SA-A2CORD)

p. 323

Datasheet

ОПРОСНЫЙ ЛИСТ НА ВЗРЫВОБЕЗОПАСНЫЕ И ПОЖАРОБЕЗОПАСНЫЕ ТЕРМОШКАФЫ (КОЖУХИ) ГТГ, УВГ (КШ)Максимально допустимые внешние габариты шкафа

В = _______мм Ш = _______ммГ = _______мм

Максимально допустимый вес шкафа (кожуха) _______ кг

Материал изготовления корпуса Материал изготовления утеплителя

Малоуглеродистая сталь с лакокрасочным покрытием (коэф. теплопередачи 5,5 Вт/м2 К) Нержавеющая сталь 03Х18Н10 (AISI304) (коэф. теплопередачи 4,5 Вт/м2 К) Ударопрочный бесшовной химически инертный полимер (коэф. теплопередачи

3,5 Вт/м2 К) Коррозионностойкий модифицированный алюминиево-кремниевый сплав (коэф.

теплопередачи 12 Вт/м2 К)

Без утеплителя Металлизированный армированный утеплитель Негорючий экструзионный вспененный полимер

Способ крепления

Крепление к стене/раме Крепление к бетонному

основанию Напольная установка.

Высота подставки ______ мм

Крепление к морской палубе Разъемная установка на трубу

(горизонтальная или вертикальная) Крепление к опоре

Установка в зону

Группа смеси: IIА IIВ IIС IIICТемпературный класс: Т1 Т2 Т3 Т4 Т5 Т6Зона установки: Зона 0 Зона 1 Зона 2

Невзрывоопасная пожароопасная зона РН

Применение Установка на открытом воздухе УХЛ1 Установка на морской платформе или судне ОМ1 Установка в неотапливаемом помещении Установка под землей Установка в отапливаемом помещении

Географическая точка установки шкафов (регион, ближайший населенный пункт) или температура окружающей среды

от –____ °С до +____ °С

Перепады температурыМощность потерь оборудования/

носителя (самонагревания) внутри шкафа (кожуха)

Место для рисунка заказчика с примерным расположением узлов и местами их крепления

Низшая t окружающей среды в месте установки ____°СМакс. t окружающей среды в месте установки ____°СЖелаемая внутренняя t ____°С или поддерживаемая t внутри шкафа: от ____°С до ____°С

Минимальная _____Вт Максимальная _____ВтПостоянная _____ВтСредняя _____Вт

Коэффициент заполнения шкафа (кожуха) Необходимое внутреннее пространство____ (0 – пустой шкаф, 10 – весь объем шкафа занят оборудованием) В = ___ мм Ш = ___ мм Г = ___ мм

Тип климатического устройства шкафа (кожуха) Требуемый способ защиты оборудования заказчика от действия агрессивных сред

Пассивная С электрообогревом с теплоотводом — полупроводниковый охладитель IP66/68 с теплоотводом — наружный обдув вентилятором IP55 с теплоотводом — вентилятор для проветривания и охлаждения IP05

Напряжение электропитания климатического устройства ______В АС DC

Герметичный корпус, IP66 Поддержание избыточного давления (малый расход сухого

воздуха) IP67 Герметичный корпус, стойкий к затоплению IP68 Продув сухим воздухом (большой расход сухого воздуха) IP66

Антивандальная защита Освещение

Корпус из стали 4мм Замок в двери Звуковая сигнализация Удаленное видеонаблюдение Герконовый дверной охранный извещатель Возможность установки навесного замка Противосъемное крепление (разной конструкции в зависимости от способа установки)

Светильник для освещения внутри Концевой выключатель двери Маскировочный светильник для осещения внутри Выключатель

Звукоизоляция Устройства для монтажа оборудования заказчика

Облицовка шумозащитным материалом Внутренние обшивка-панели с перфорацией круглыми отверсти-ями на боковых стенках под саморез для последующего крепления монтажных элементов

Угол открывания дверей не менее 105° Крепление для размещения блков в 19” стандарте

Ввод кабелей и трубКабельные вводы для кабелей

Неброни-рованных

Бронированных / с оплеткой

Гибкого металлору-

кава

Полимерной гофры

Трубной электропро-

водкиd шт.

123

Кабельные вводы для кабелей

Стальная труба

Стальная труба в теплоизо-

ляции

Пластико-вая труба

Медная труба

Резиновый шланг

Металличе-ский гибкий

шлангd шт.

123

Проходки для кабелей/труб В = ___ мм Ш = ___ мм В = ___ мм Ш = ___ мм

Защита оборудования заказчика от пожара

Пожарный тепловой извещатель Пожарный извещатель пламени Автономная система газового пожаротушения Дверные уплотнители – СТОП ОГОНЬ

Устройства для доставки и установки

Транспортные рым-болты для установки краном Установка на поддон для погрузчика (снимается при монтаже)

Примечания заказчикаДополнительное оборудование

Встроенный блок питания Uвх___В, Uвых___В, Iвых___А С аккумулятором, емкость ___А ч Wi-Fi антенна, коммутатор или точка доступа Дистанционный контроль и управление системой по протоколам удаленного доступа

HTTP и SNMP по Ethernet или другим протоколам

Количество, шт.

Контактная информация

Организация: Почтовый адрес:Контактное лицо: Тел./факс: E-mail:

p. 325

ComponentsCable glands,

plugs, adapters

p. 393

Page 3: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

304

GTG-SHKAF KSH/TERMO-BOX

Hea

ting

equi

pmen

t

• Temperature inside GTG-SHKAF cabinet is increased by an explosion-proof heater 600 W with an additional au-tomatic temperature control device.

• Heating element control and power input are carried out via explosion-proof boxes.

• Temperature inside the cabinet can be regulated by means of different thermostats or an automatic system on the base of a programmable logic controller.

• Inner cabinet walls are covered with a specialized layer of ultra-light heat-resistant metalized armored heat insulator for ensuring efficient thermal insulation, or an ad-ditional extrusion polymer foam coating is applied for ther-mal insulation increase.

MARKING

II Gb or III Db

III Db

1Ex d e IIC T3 Gb (for version /OBOGREV)

MINING EQUIPMENT MARKINGРН1, РН2

CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244РОСС RU.EX01.B00004TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666

CODESGOST 12.2.007.0-75GOST 14254-96GOST R IEC 60079-0-2011GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.1-2002 (IEC 60079-1:1998)GOST 30852.8-2002Electrical Installation Code Ch. 7.3, Ch. 7.4TR CU 012/2011, TR CU 004/2011GOST 31441.1-2011 (EN 13463-1:2001)GOST 24754-2013GOST 30852.20-2002

TECHNICAL CHARACTERISTICS

Installation

Category II for gas subgroup IIA, IIB, IIC; zones 1, 2;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities

Relative air humidity

98%

Enclosure material

Low-carbon steel (for GTG-SHKAF-M enclosures)Stainless steel (for GTG-SHKAF-N enclosures)

Sealant

Silicone rubber (in cover groove)

Grounding

2 stainless steel ground clamps (inner and outer)

Thermal insulation

Low heat-conducting composite materials (without application of mineral wool)

Cable glands arrangement

As per customer’s specification

Climatic category

NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)

IP 5466

Page 4: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

305

GTG-SHKAF KSH/TERMO-BOX

Hea

ting

equi

pmen

t

OPTIONS, ACCESSORIES AND VERSIONS

DESCRIPTION MARKING

Cable and pipe transits /KPG

Floor mounting on a frame /RAMA

Modular version as per customer’s layout /MODULNYI

Wall mounting /STENA

Material of enclosure stainless steel 08X18Н10 as per GOST 5632-72 (AISI 304) /N

Electrical heating /OBOGREV

Window /O

Nameplate with inscription as per customer’s specification /NADPIS «_»

Earthquake-resistant version /MSK-64

Indication of voltage presence on current-conducting terminals /IN

Non-explosion-proof general industrial version /PROM

OVERALL AND MOUNTING DIMENSIONS

Temperature sensor

GTG-PLASTINA

Temperature sensor

Page 5: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

306

GTG-SHKAF KSH/TERMO-BOX

Hea

ting

equi

pmen

t

Cabinet enclosure type Dimensions, mmA B C

GTG-SHKAF-M-806021 800 600 210GTG-SHKAF-M-806025 800 600 250GTG-SHKAF-M-806030 800 600 300GTG-SHKAF-N-806030 800 600 300GTG-SHKAF-M-808030 800 800 300GTG-SHKAF-M-1006021 1000 600 210GTG-SHKAF-M-1006025 1000 600 250GTG-SHKAF-M-1006030 1000 600 300GTG-SHKAF-M-1008030 1000 800 300GTG-SHKAF-N-1008030 1000 800 300GTG-SHKAF-M-1206021 1200 600 210GTG-SHKAF-M-1206030 1200 600 300GTG-SHKAF-M-1208030 1200 800 300GTG-SHKAF-N-1208030 1200 800 300

М — low-carbon steel enclosures with a cover on hinges, cover fastening with a lockN — stainless steel enclosures with a cover on hinges, cover fastening with a lockOther enclosure size upon approval.

FORMATION OF MARKING

GTG-SHKAF – X – X – X / X – TU 3400-005-72453807-07

Device typeMaterial of enclosure: low-carbon steel — M; stainless steel — NEnclosure sizeNumber and type of cable glandsOptions, accessories and versions

Example of order: GTG-SHKAF-M-808030-8KNV2О(B)/RAMA – TU 3400-005-72453807-07.

Table of names matchingPrevious international name “ZAVOD GORELTEX” Co. Ltd.

TU 3400-005-72453807-07Previous international name “ZAVOD GORELTEX” Co. Ltd.

TU 3400-005-72453807-07Explosion-proof all-weather wall-mounted cabinets with thermal insulation

KSH/TERMO-BOX GTG-SHKAFKSH/TERMO-BOX-МPЗ-806021 GTG-SHKAF-M-806021KSH/TERMO-BOX-МPЗ-806025 GTG-SHKAF-M-806025KSH/TERMO-BOX-МPЗ-806030 GTG-SHKAF-M-806030KSH/TERMO-BOX-CPЗ-806030 GTG-SHKAF-N-806030KSH/TERMO-BOX-МPЗ-808030 GTG-SHKAF-M-808030KSH/TERMO-BOX-МPЗ-1006021 GTG-SHKAF-M-1006021KSH/TERMO-BOX-МPЗ-1006025 GTG-SHKAF-M-1006025KSH/TERMO-BOX-МPЗ-1006030 GTG-SHKAF-M-1006030KSH/TERMO-BOX-МPЗ-1008030 GTG-SHKAF-M-1008030KSH/TERMO-BOX-CPЗ-1008030 GTG-SHKAF-N-1008030KSH/TERMO-BOX-МPЗ-1206021 GTG-SHKAF-M-1206021KSH/TERMO-BOX-МPЗ-1206030 GTG-SHKAF-M-1206030KSH/TERMO-BOX-МPЗ-1208030 GTG-SHKAF-M-1208030KSH/TERMO-BOX-CPЗ-1208030 GTG-SHKAF-N-1208030

Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNVM, KNVZ refer to p.393

Page 6: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

307

GTG-OSHA RETO-PLATE-HS-480W-T190

Hea

ting

equi

pmen

t

• GTG-OSHA are intended for maintenance of preset positive temperature in cabinets for control and measuring equipment, automation cabinets, and cabinets with thermal insulation.

• High operational reliability is guaranteed by the exclusion of temperature fluctuations exclusion or maintenance of required minimum temperature.

• Heating plates are used for prevention of equipment malfunctioning caused by current leakage on electric parts or other malfunctions which can occur due to corrosion of mechanical parts of installations and electric contacts caused by dew point occurrence.

• GTG-OSHA explosion-proof heaters are equipped with built-in thermostat that does not allow the heating plate temperature to rise above 190 °С.

• Heater design causes so called ‘fireplace effect’ that enables even heat distribution inside boxes and cabinets.

MARKING

1Ex e II T3 Gb X

1Ex s II T3 Gb

Ex tb IIIC T200°C Db X

MINING EQUIPMENT MARKINGРН1РН2

CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247РОСС RU.EX01.B00002TC RU C -RU.МЛ02.B.00625Maritime Register upon request (check cost and terms of Type Approval Certificate issuance with manager)TU 3400-007-72453807-07

CODESGOST 14254-96 (IEC 529-89)GOST R IEC 60079-0-2011GOST 30852.0-2002 (IEC 60079-0: 1998)GOST 30852.8-2002GOST IEC 61241-1-1-2011GOST R IEC 62086-1-2003GOST 24754-2013TR CU 012/2011, TR CU 004/2011Electrical Installation Code Ch. 7.3, Ch. 7.4GOST 22782.3-77GOST 12.2.007.0-75GOST 30852.20-2002GOST R IEC 60079-31-2010

TECHNICAL CHARACTERISTICS

Installation

Category II for gas subgroup IIA, IIB, IIC; zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities

Supply voltage, V

~220 В (50/60 Hz)

Power, W

480

Current consumption, A

2

Power density, W/cm2

2

Maximum surface heating temperature, °С

190

Insulation resistance, MOhm

>100

Operating position in space

any

Climatic category

NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)

IP 6768

Page 7: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

308

GTG-OSHA RETO-PLATE-HS-480W-T190

Hea

ting

equi

pmen

t

OPTIONS, ACCESSORIES AND VERSIONS

DESCRIPTION MARKING

Non-explosion-proof general industrial version /PROM

OVERALL AND MOUNTING DIMENSIONS

Silicone wires, length: L=1000 mm1.0 mm2 Wire in insulation

Temperature controllers

Model Type Heating temperature, °СDVG-TERMOSTAT2-0.-1.10

Fixed temperature7–13

DVG-TERMOSTAT2-0.4.15 12–18DVG-TERMOSTAT2-0.64.75 72–78

GTG-PT-0.120 Programmable temperature 0...120DVG-TERMOSTAT-M0.60 Manual setting 0...60DVG-TERMOSTAT-M0.80 0...80

FORMATION OF MARKING

GTG-OSHA – TU 3400-005-72453807-07Device type

Example of order: GTG-OSHA – TU 3400-005-72453807-07.

Page 8: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

309

GTG-PLASTINA2 RETO-PLATE-CAVO-150W/300W/600W

Hea

ting

equi

pmen

t

• GTG-PLASTINA2 explosion-proof heating plates are intended for heating of flat and curved surfaces, such as reservoirs with petroleum products, containers, pipes surfaces, reservoirs with lubricants, heating of materials being refined, technological structures, hydraulic drives and joints of power devices etc.

• Explosion-proof heating plates are manufactured from special heat-resistant rubber and are equipped with a built-in thermostat that does not allow heating temperature to rise above 190 °С. It is recommended to apply PG-TERMOKLEY sealant or heat-conducting PG-TERMOPASTA paste for better transmission of thermal energy.

• GTG-PLASTINA2 explosion-proof heating plates shall be fastened directly to the heated surfaces of technological objects and structures and are intended for operation in the harshest operating conditions, where resistance of the equipment to wide temperature ranges, moisture and dust is required.

MARKING

1Ex e II T3 Gb

Ex tb IIIC T200°С Db

1Ex e II T3 Gb X

Ex tb IIIC T200°С Db X

MINING EQUIPMENT MARKINGРН1РН2

CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247РОСС RU.EX01.B00002TC RU C -RU.МЛ02.B.00625Maritime Register upon request (check cost and terms of Type Approval Certificate issuance with manager)TU 3400-007-72453807-07

CODESGOST R IEC 60079-0-2011GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST R IEC 62086-1-2003GOST 30852.8-2002TR CU 012/2011, TR CU 004/2011GOST IEC 61241-1-1-2011GOST 24754-2013Electrical Installation Code Ch. 7.3, Ch. 7.4GOST 12.2.007.0-75GOST 30852.20-2002GOST R IEC 60079-31-2010

TECHNICAL CHARACTERISTICS

Installation

Category II for gas subgroup IIA, IIB, IIC; zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities

Supply voltage, V

~220 В (50/60 Hz)

Power, W

150, 300, 600

Power density, W/cm2

0.3

Maximum surface heating temperature, °С

190

Insulation resistance, MOhm

>100

Operating position in space

any

Climatic category

NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)

OPTIONS, ACCESSORIES AND VERSIONS

DESCRIPTION MARKING

Non-explosion-proof general industrial version /PROM

67IP

Page 9: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

310

GTG-PLASTINA2 RETO-PLATE-CAVO-150W/300W/600W

Hea

ting

equi

pmen

t

OVERALL AND MOUNTING DIMENSIONS

600

Wire 1.0 mm2 in insulation

BraidingProtective layer

Silicone wires

Model Size A, mm Size B, mm Power, W Power density, W/cm2

GTG-PLASTINA2-150/T190 220 220 150 0,31GTG-PLASTINA2-300/T190 305 305 300 0,32GTG-PLASTINA2-600/T190 305 610 600 0,30

FORMATION OF MARKING

GTG-PLASTINA2 – X / Т190 / X – TU 3400-007-72453807-07Device typePower, W: 150; 300; 600Options, accessories and versions

Example of order: GTG-PLASTINA2-300/T190 – TU 3400-007-72453807-07

Page 10: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

311

GTG-PLASTINA1 RETO-PLATE-T190

Hea

ting

equi

pmen

t

• GTG-PLASTINA1 explosion-proof heating plates are intended for heating of flat and curved surfaces. The plates shall be fastened directly to the heated surfaces of technological objects and structures and are intended for operation in the harshest operating conditions, where resistance of the equipment to wide temperature ranges, moisture and dust is required.

• Explosion-proof heating plates are manufactured from special heat-resistant rubber, have earthing grid, an explosion-proof gland for power connection and are equipped with a built-in thermostat that does not allow heating temperature to rise above 190 °С.

• It is recommended to apply PG-TERMOKLEY sealant or heat-conducting PG-TERMOPASTA paste for better transmission of thermal energy.

MARKING

1Ex e II T3 Gb X

Ex tb IIIC T200°С Db X

MINING EQUIPMENT MARKINGРН1РН2

CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247РОСС RU.EX01.B00002TC RU C -RU.МЛ02.B.00625Maritime Register upon request (check cost and terms of Type Approval Certificate issuance with manager)TU 3400-007-72453807-07

CODESGOST R IEC 60079-0-2011GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST R IEC 62086-1-2003GOST 30852.8-2002TR CU 012/2011, TR CU 012/2011GOST IEC 61241-1-1-2011GOST 24754-2013Electrical Installation Code Ch. 7.3, Ch. 7.4GOST 12.2.007.0-75GOST 30852.20-2002GOST R IEC 60079-31-2010

TECHNICAL CHARACTERISTICS

Installation

Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities

Supply voltage, V

~220 (50/60 Hz)

Power, W

300, 600, 1200

Maximum surface heating temperature, °С

190

Insulation resistance, MOhm

>100

Operating position in space

any

Climatic category

NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)

OPTIONS, ACCESSORIES AND VERSIONS

DESCRIPTION MARKING

Non-explosion-proof general industrial version /PROM

66IP

Page 11: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

312

GTG-PLASTINA1 RETO-PLATE-T190

Hea

ting

equi

pmen

t

OVERALL AND MOUNTING DIMENSIONS

Terminal box

Model Mounting dimensions, mm Power, W Power density, W/cm2

A BGTG-PLASTINA1-300/T190 305 305 300 0,32GTG-PLASTINA1-600/T190 610 305 600 0,28

GTG-PLASTINA1-1200/T190 610 610 1200 0,32

GTG-PLASTINA1 heating plates can be completed with temperature control devices if heating below 190°С is required.

Temperature controllersModel Type Heating temperature, °С

DVG-TERMOSTAT2-0.-1.10Fixed temperature

7–13DVG-TERMOSTAT2-0.4.15 12–18

DVG-TERMOSTAT2-0.64.75 72–78GTG-PT-0.120 Programmable temperature 0...120

DVG-TERMOSTAT-M0.60 Manual setting 0...60DVG-TERMOSTAT-M0.80 0...80

FORMATION OF MARKING

GTG-PLASTINA1 – X / Т190 / X – TU 3400-007-72453807-07Device typePower, W: 300; 600; 1200Options, accessories and versions

Example of order: GTG-PLASTINA1-600/T190 – TU 3400-007-72453807-07.

Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNVM, KNVZ refer to p.393

Page 12: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

313

GTG-KABEL1 RETO-CORD/S

Hea

ting

equi

pmen

t

• Heating material shrinks at low temperatures creating lots of carbon current-conducting paths and reducing electrical resistance. When electric current flows via heating element, a thermal energy output occurs.

• Heating element material expands in warmer sections of the explosion-proof heating cable, reducing number of current-conducting paths. Electrical resistance of heating element material increases, resulting in a significant thermal energy output reduction.

• Expansion of material of heating element in hot spots of the heating cable almost entirely tears current-conducting paths. Along with that, electric resistance of material becomes very high, which leads to significant reduction of heat energy output.

MARKING

1Ex e II T4...T2 Gb X

Ex tb IIIC T135°С...T300°С Db X

MINING EQUIPMENT MARKINGРН1, РН2

CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247РОСС RU.EX01.B00002TC RU C -RU.МЛ02.B.00625TU 3400-007-72453807-07

CODESGOST R IEC 60079-0-2011GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST R IEC 62086-1-2003GOST 30852.8-2002TR CU 012/2011, TR CU 004/2011GOST IEC 61241-1-1-2011GOST 24754-2013Electrical Installation Code Ch. 7.3, Ch. 7.4GOST 12.2.007.0-75GOST 30852.20-2002GOST R IEC 60079-31-2010

TECHNICAL CHARACTERISTICS

Installation

Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities

Supply voltage, V

~220 (50/60 Hz)

Operating position in space

any

Climatic category

NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)

OPTIONS, ACCESSORIES AND VERSIONS

DESCRIPTION MARKING

Non-explosion-proof general industrial version /PROM

Cable element for heating cable end termination /GTG-ZGK

68IP180

105135

Page 13: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

314

GTG-KABEL1 RETO-CORD/S

Hea

ting

equi

pmen

t

• Low-temperature low-power flexible heating cable with temperature self-regulation

Heating cables W/mMaximum main-

tained operating temperature t °C

Maximum cable length through the circuit breaker, during switching on at minimum operating

temperature, meters Max t °C

16А 20А 25А 32А 40А

Explosion-proof reinforced low-temperature type GTG-KABEL1-65 with outer fluoropolymer insulation

10 65°C 128 160 200 — — 70°C15 88 110 137 176 —

DIAGRAM OF DEPENDENCE OF LINEAR POWER ON TEMPERATURE GTG-KABEL1-65-10, GTG-KABEL1-65-15

Temperature, °C

Line

ar p

ower

, W/m

10 W

10 20 30 40 50 60

30

20

10

0

15 W

• Low-temperature high-power flexible heating cable with temperature self-regulation

Heating cables W/mMaximum main-

tained operating temperature t °C

Maximum cable length through the circuit breaker, during switching on at minimum operating

temperature, meters Max t °C

16А 20А 25А 32А 40А

Explosion-proof reinforced low-temperature type GTG-KABEL1-65 with outer fluoropolymer insulation

30 65°C 44 55 69 88 110 70°C50 26 33 41 53 66

DIAGRAM OF DEPENDENCE OF LINEAR POWER ON TEMPERATURE GTG-KABEL1-65-30, GTG-KABEL1-65-50

Temperature, °C

Line

ar p

ower

, W/m

50 W

30 W

10 20 30 40 50 60

50

40

30

20

10

0

Self-regulating heating cable structure:1. Current-conducting stranded tin-plated copper cores.2. Thremoresistive element. 3. Internal insulation for provision of dielectric strength, moisture tightness, protection against impact loads and abrasion,

as well as protection against chemical exposure for heat-producing matrix. 4. Outer insulation. 5. Copper tin-plated screen. 6. Fluoropolymer outer protective sheath is applied in conditions of increased humidity as well as under the exposure of

organic substances and solvents or other aggressive substances in common areas or in areas classified as hazardous (not applied for /PROM version).

Page 14: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

315

GTG-KABEL1 RETO-CORD/S

Hea

ting

equi

pmen

t

• Mid-temperature high-power flexible heating cable with temperature self-regulation

Heating cables W/mMaximum main-

tained operating temperature t °C

Maximum cable length through the circuit breaker, during switching on at minimum operating

temperature, meters Max t °C

16 А 20 А 25 А 32 А 40 АExplosion-proof reinforced low-temperature type GTG-KABEL1-105 with outer reinforced fluoropolymer insulation 50 105°C 32 40 50 65 80 120°C

DIAGRAM OF DEPENDENCE OF LINEAR POWER ON TEMPERATURE GTG-KABEL1-105-50

50 W

Temperature, °C

Line

ar p

ower

, W/m

• High-temperature high-power flexible heating cable with temperature self-regulation

Heating cables W/mMaximum main-

tained operating temperature t °C

Maximum cable length through the circuit breaker, during switching on at minimum operating

temperature, meters Max t °C

16 А 20 А 25 А 32 А 40 АExplosion-proof reinforced low-temperature type GTG-KABEL1-130 with outer reinforced fluoropolymer insulation 50 130°C 35 45 55 70 90 140°C

DIAGRAM OF DEPENDENCE OF LINEAR POWER ON TEMPERATURE GTG-KABEL1-130-50

70

60

50

40

30

20

10

010 20 30 40 50 60 70 80 90 100 110 120 (°C)

50 W

Temperature, °C

Line

ar p

ower

, W/m

FORMATION OF MARKING

GTG-KABEL1 – X – X – X / X – TU 3400-007-72453807-07

Device typeMaximum maintained operating temperature t °C: 65; 105; 130Power, W: 10; 15; 30; 50Length in metersOptions, accessories and versions

Example of order: GTG-KABEL1-65-15-100 – TU 3400-007-72453807-07.

Page 15: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

316

GTG-ZGK MC-CORD

Hea

ting

equi

pmen

t

• Bare ends require termination within the process of heating cable installation in order to ensure safe operation. Hazardous atmosphere conditions require special meas-ures for explosion protection provision.

• GTG-ZGK cable element is intended for explo-sion-proof end termination of the heating cable. Inner vol-ume of the cable element shall be filled with compound for increased degree of explosion protection. For indication of voltage presence on current-conducting wires GTG-ZGK modification with a built-in LED indicator can be provided.

MARKING

Ex d IIC Gb U

MINING EQUIPMENT MARKINGРН1, РН2

CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247РОСС RU.EX01.B00002TU 3400-005-72453807-07

CODESGOST R IEC 60079-0-2011GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.1-2002 (IEC 60079-1:1998)Electrical Installation Code Ch. 7.3, Ch. 7.4TR CU 012/2011GOST 12.2.007.0-75GOST 30852.20-2002GOST 24754-2013

TECHNICAL CHARACTERISTICS

Installation

Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities

Mass, kg

0,1

Enclosure material

Galvanized steel: ONickel-plated brass, resistant to hydrogen sulfide and hydrochloric acid vapors and salt spray: NKStainless steel: N

Climatic category

NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)

OPTIONS, ACCESSORIES AND VERSIONS

DESCRIPTION MARKING

Indication of voltage presence on current-conducting wires /IN

66IP

Page 16: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

317

GTG-ZGK MC-CORD

Hea

ting

equi

pmen

t

GTG-ZGK WITHOUT INDICATION

1) Plug2) GTG-KABEL1 heating cable3) PG-COMPOUND compound4) PG-REZBA-F sealant5) Special heatproof silicone sealant

Thread code Thread type Size of the crimped cable1 1/2” Rc 12 x 7,5

2 3/4” Rc

12 x 7,515 x 8

2 x 12 x 7,52 x 15 x 8

SEALING RUBBERS FOR HEATING CABLES

FORMATION OF MARKING

GTG-ZGK – X – X – X / X – TU 3400-007-72453807-07Device typeCode of typical size of threadTypical size of crimped cableEnclosure material: galvanized steel — О; Nickel-plated brass – NK; stainless steel – N Options, accessories and versions

Example of order: GTG-ZGK2-15x8-N – TU 3400-005-72453807-07.

Page 17: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

318

GTG-RADIATOR RETO-PLATE-RADIATOR/M

Hea

ting

equi

pmen

t

• GTG-RADIATOR explosion-proof plate heating ele-ments are intended for heating and maintenance of pos-itive preset temperature in technological rooms, automa-tion cabinets, units with control and measuring and other equipment which requires positive temperature for normal operation.

• Plate heaters allow to evenly heat air in confined area; they are explosion-proof and reliable heating elements which exclude direct contact of heating elements with in-stalled equipment. Flat silicone explosion-proof heating el-ement is fastened to the aluminum plate in the protective metal housing with perforation. More efficient heating is reached by an additional special layer of heat insulation in the point where the plate is fastened to the housing.

• GTG-RADIATOR heating element is a vibration-resist-ant and corrosion-resistant silicone plate. The heater does not accumulate dust due to flat structure of the heating element.

MARKING

1Ex e II T3 Gb X

Ex tb IIIC T200°С Db X

MINING EQUIPMENT MARKINGРН1, РН2

CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.АА87.В.00247TC RU C -RU.МЛ02.B.00625РОСС RU.EX01.B00002Maritime Register upon request (check cost and terms of Type Approval Certificate issuance with manager)TU 3400-007-72453807-07

CODESGOST R IEC 60079-0-2011GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST R IEC 62086-1-2003GOST 30852.8-2002TR CU 012/2011, TR CU 004/2011GOST IEC 61241-1-1-2011GOST 24754-2013Electrical Installation Code Ch. 7.3, Ch. 7.4GOST 12.2.007.0-75GOST 30852.20-2002GOST R IEC 60079-31-2010

TECHNICAL CHARACTERISTICS

Installation

Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities

Supply voltage, V

~220 V (50/60 Hz)

Power, W

600, 1200

Electrical diagram

Direct connection to L, N, PE terminals with 4mm2 cross-section

Mass, kg

10

Thread on connecting holes

Rc ½” taper pipe

Operating position in space

any

Climatic category

NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)

OPTIONS, ACCESSORIES AND VERSIONS

DESCRIPTION MARKING

Enclosure temperature limitation /100

Nameplate with inscription as per customer’s specification /NADPIS «_»

OVERALL AND MOUNTING DIMENSIONS GTG-RADIATOR-600

66IP

Page 18: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

319

GTG-RADIATOR RETO-PLATE-RADIATOR/M

Hea

ting

equi

pmen

t

4 holes ø7

GTG-RADIATOR-1200

RETO-PLATE-RADIATOR/SA

60ТС RU C-RU.ГБ05.В.00394 / ТС RU C-RU.ГБ05.В.00432

Tокр - °C + °C IP

1200

60

техническая поддержка +7 800 100 100 4,

2ExeIIT3 / 1Ex e II T3 Gb X

R

ОТКЛЮЧИВ ОТ СЕТИ

R

ОТКРЫВАТЬ

НАНИО "ЦСВЭ"

220n n

66

S.N.fU Вт 50 Гц

810

392

192

252

712 4 holes ø7

FORMATION OF MARKING

GTG-RADIATOR – X – X / X – TU 3400-007-72453807-07Device typePower, W: 600, 1200Dimension type of the cable glandOptions, accessories and versions

Example of order: GTG-RADIATOR-1200-KNV1N – TU 3400-007-72453807-07.

Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNVM, KNVZ refer to p.393

Page 19: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

320

GTG-PT SA-TERMOSTAT-D

Hea

ting

equi

pmen

t

• Option of actuation temperature setting by an opera-tor within the range from -40°C to +110°C;

• Option of setting temperature difference between Tactuation and Treturn within the range from 0°C to 10°C from the value of actuation temperature;

• Two electrically independent changeover contacts;• Option of connection of controlled objects with cur-

rent consumption up to 16 A and alternating voltage up to 250 V;

• Option of remote sensor installation at a distance of up to 30 meters to the device;

• Small sizes of the sensor, simple installation; • Operation of the product at ambient temperature with-

in the range from -60°C to +60°C;• Temperature sensor state control and switching to

emergency mode in case of signal absence; • Simultaneous control of up to 4 external devices; • Simple remote temperature measurement in the se-

lected environment.

MARKING

1Ex d e [ib] IIC T5 Gb (for GTG-PT control unit)

Ex d [ib] IIC U (for temperature sensor)

MINING EQUIPMENT MARKINGРН1, РН2

CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244РОСС RU.EX01.B00004Maritime Register upon request (check cost and terms of Type Approval Certificate issuance with manager)TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666

CODESGOST 12.2.007.0-75GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.1-2002 (IEC 60079-1:1998)GOST 30852.8-2002GOST 30852.10-2002 (IEC 60079-11:1999)GOST 14254-96 (IEC 529-89)Electrical Installation Code Ch. 7.3, Ch. 7.4TR CU 012/2011GOST 30852.20-2002GOST 24754-2013

TECHNICAL CHARACTERISTICS

Installation

Category II for gas subgroup IIA, IIB, IIC; zones 1, 2;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities

Operating voltage, V

~220 V (50/60 Hz)

Alternating current consumption

20 mA

Maximum switched alternating current

16 А

Maximum switched alternating voltage

250 V

Maximum switched direct current

16 А

Maximum switched direct voltage

220 V

Mass

up to 5 kg

Climatic category

NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)

66IP

Page 20: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

321

GTG-PT SA-TERMOSTAT-D

Hea

ting

equi

pmen

t

OPTIONS, ACCESSORIES AND VERSIONS

DESCRIPTION MARKING

Version with additional mounting plates /PLANKA

Increase measured temperature range -40°C…+125°C; /T125

Increased switched current ( X – value of the current, A) /X

Special version of sensor housing as per customer’s specification /KD

OVERALL AND MOUNTING DIMENSIONS

MOUNTING DIMENSIONS OF GTG-PT IN STANDARD VERSION

174

22

4,5

27

6

18

2

125,5 135

R3,3

MOUNTING DIMENSIONS OF GTG-PT/PLANKA IN A VERSION WITH ADDITIONAL MOUNTING PLATES

64

175

R4,5

Page 21: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

322

GTG-PT SA-TERMOSTAT-D

Hea

ting

equi

pmen

t

EXPLOSION-PROOF TEMPERATURE SENSOR

21

13

M12x1.5 – 6g

FORMATION OF MARKING

GTG-PT – X – X / X – TU 3400-007-72453807-07Device nameLength of temperature sensor’s cable in meters (maximum length 30 m)Number and type of cable glandsOptions, accessories and versions

Example of order: GTG-PT-10-2KNV20/PLANKA – TU 3400-005-72453807-07.

Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNVM, KNVZ refer to p.393

Page 22: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

323

GTG-VK2 SA-A2CORD

Hea

ting

equi

pmen

t

• Application of GTG-VK2 allows to simplify installation and excludes heat-ing cable damage during its input under heat insulation, as well as it allows to splice ends of the heating cable for T-shaped branches.

• GTG-VK2 are applied for all types of GTG heating equipment and cables of third party manufacturers.

• Design of OKT-2 supporting brackets enables convenient mounting on the pipe with round cross-section. The box shall be fastened to the pipe with a metal fastening clamp which is included in the set. The clamp ensures relia-bility of the grounding circuit between the pipe and the enclosure.

• Several supporting brackets can be installed on the enclosure upon cus-tomer’s request for the connection of more than 3 heating elements; arrange-ment of terminal blocks inside the box can be amended.

MARKING

1Ex e II T6...T4 Gb

Ex tb IIIC T70°С...T135°С Db

MINING EQUIPMENT MARKINGРН2

CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244TC RU C -RU.МЛ02.B.00626РОСС RU.МШ06.Н00147TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666

CODESGOST R IEC 60079-0-2011GOST 12.2.007.0-75GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.8-2002TR CU 012/2011, TR CU 004/2011GOST IEC 61241-1-1-2011Electrical Installation Code Ch. 7.3, Ch. 7.4OD 5.2-093-2004GOST 30852.20-2002GOST 24754-2013GOST R IEC 60079-31-2010

TECHNICAL CHARACTERISTICS

Installation

Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Non-hazardous areas of ground facilities and open sites;Underground mines non-hazardous with gas (methane) and coal dust;Dangerous production facilities

Maximum voltage, V

800

Maximum current, A

175

Mass, kg

3

Size of connected heating cable, mm

up to 17

Connected power cable diameter and dimension type of the cable gland

from 6 mm to 12 mm for KNV1 cable gland (by default)from 12 mm to 18 mm for KNV2 cable glandfrom 6 mm to 12 mm for KOV1 cable glandfrom 12 mm to 18 mm for KOV2 cable glandother cable gland upon customer’s request

Bracket height

H=150 mm (other height upon customer’s request with order from 1000 pcs.)

Grounding

2 stainless steel ground clamps (inner and outer)

Climatic category

NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)

IP 6667

HOLOD

Page 23: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

324

GTG-VK2 SA-A2CORD

Hea

ting

equi

pmen

t

OPTIONS, ACCESSORIES AND VERSIONS

DESCRIPTION MARKING

Non-explosion-proof version /PROM

Indication of voltage presence on current-conducting wires /IN

Other bracket height (with order from 1000 pcs.) /H (height in millimeters)

Round heating cable /KGK

Option of temperature sensor connection /PKT

U-shaped base for increase of bracket fixation.Fastening to the pipe with 2 clamps.Application of U-shaped base does not influence bracket height

/P

OVERALL AND MOUNTING DIMENSIONS

SEALING RUBBER FOR HEATING CABLE FOR GTG-VK2

Enclosure typeDimensions Maximum recommended number of terminals per wire cross-section, mm2

А B C H 2,5 4 6 10

GTG-VK2-111109 112 112 91 150 14 10 9 7

GTG-VK2-171109 172 112 91 150 23 17 14 12

GTG-VK2-141410 149,5 149,5 107 150 32 22 19 15

FORMATION OF MARKING

GTG-VK2 – X – X – X – X / X – TU 3400-005-72453807-07Product nameEnclosure size codeDiameter of a heated pipeType of installed terminalsNumber and dimension type of cable glandsOptions, accessories and versions

Example of order: GTG-VK2-111109-100-4С2-1KNV1(А)-1KOV1(B) – TU 3400-005-72453807-07.

Table of names matchingPrevious international name “ZAVOD GORELTEX” Co. Ltd.

TU 3400-005-72453807-07 The Customs Union name “ZAVOD GORELTEX” Co. Ltd.

TU 3400-005-72453807-07 SA-A2CORD GTG-VK2

SA-A2CORD /SA11 GTG-VK2-111109SA-A2CORD /SA14 GTG-VK2-141410SA-A2CORD /SA20 GTG-VK2-171109

Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNVM, KNVZ refer to p.393

Page 24: Heating equipment › pdf › katalog › goreltex_eng... · Heating equipment Heaters GTG-SHKAF (KSH/TERMO-BOX) thermo cabinet p. 304 Heater with a thermostat 190°С GTG-OSHA (RETO-PLATE-HS-480W-T190)

325

Datasheet

Hea

ting

equi

pmen

t

GORELTEX DATASHEET FOR GTG, UVG (KSH) EXPLOSION-PROOF AND FIREPROOF THERMO CABINETS (HOUSINGS)Maximum allowed outer

dimensions of the cabinetH = _______mm W = _______mmD = _______mm

Maximum allowed weight of the cabinet (housing) _______ kg

Material of enclosure Material of heat insulation

Low-carbon steel with varnish-and-paint coating (heat transfer coefficient 5,5 W/m2K) Stainless steel grade 03Х18Н10 (AISI304) (heat transfer coefficient 5,5 W/m2K) Impact-resistant seamless inert polymer (heat transfer coefficient 3,5 W/m2K) Modified corrosion-resistant aluminum-silicon alloy (heat transfer coefficient 12 W/m2K)

Without thermal insulation Metalized armored polyester Incombustible extrusion polymer foam

Method of fastening

Wall/RAMA mounting Concrete base mounting Floor mounting

Height of the base ______ mm

Sea platform mounting Dismountable installation on

a pipe (horizontal or vertical) Support mounting

Installation in the area

Group of mixture: IIА IIВ IIС IIICTemperature class: Т1 Т2 Т3 Т4 Т5 Т6Installation area: Zone 0 Zone 1 Zone 2

Non-hazardous fire-dangerous area RN

Application Open area installation NF1 Sea platform of vessel installation MU1 Installation in a non-heated space Underground installation Installation in a heated space

Geographic point of cabinet installation (region, nearest town) or ambient temperature

from –____ °С to +____ °С

Temperature extremesEquipment/carrier loss power

(self-heating) inside the cabinet (housing)

Place for customer’s drawing with approximate arrangement of

assemplies and points for their fastening

Lowest ambient t in the installation area ____°СMax. ambient t in the installation area ____°СRequired inner t ____°С or maintained t in the cabinet: from ____°С to ____°С

Minimum_____W Maximum _____WConstant _____WMedium _____W

Cabinet (housing) filling coefficient Required inner space____ (0 – empty cabinet, 10 – entire cabinet volume is filled with equipment) H=___mm W=___mm D=___mm

Cabinet (housing) climatic system type Required type of equipment protection against aggressive atmospheres

Passive With electrical heating with heat extraction – semi-conductive cooler IP66/68 with heat extraction – external fan blowing IP55 with heat extraction – fan for airing and cooling IP05

Electric supply voltage ______V АС DC

Hermetic enclosure, IP66 Excess pressure maintenance (low consumption of dry air) IP67 Hermetic enclosure, resistant to flooding IP68 Purging with dry air (high consumption of dry air) IP66

Anti-vandal protection Lighting

4 mm steel enclosure Lock in the door Sound alarm Remote video surveillance Door security alarm with reed sensor Switch Anti-theft fastening (of various design depending on the method of installation)

Light fixture for internal lighting Door limit switch Masking light fixture for internal lighting Option of padlock installation

Sound proofing Devices for customer’s equipment installation

Lining with sound-proof material Internal lining – perforated panels with round holes in side walls for a self-driving screw for further fastening of mounting elements

Door opening angle 105° Fastener for the arrangement of units in 19” standard

Cable and pipe entryCable glands for cables

Non-armored Armored/braided Flexible metal

hoseCorrugated

polymer Wiring in pipe d pcs.

123

Cable glands for cables

Steel pipe Steel pipe in heat insulation

Plastic pipe

Copper pipe

Rubber hose

Flexible metal hose d pcs.

123

Transits for cables/pipes H = ___ mm W = ___mm H = ___ mm W = ___ mm

Customer’s equipment fire protection

Heat detector Flame detector Gaseous fire suppression stand-alone system Door sealant – STOP FIRE

Devices for delivery and installation

Transport eye bolts for installation with a crane Placement on a pallet for a forklift (removed during installation)

Customer’s notesAdditional equipment

Built-in power supply unit Uinp___V, Uout___V, Iout___A With accumulator, capacity___A h Wi-Fi antenna, switching unit or access point Remote control and system control under remote access protocols HTTP and SNMP Ethernet

or other protocols.

Quantity, pcs.

Contact detailsCompany: Postal address:Contact person: Tel./fax: E-mail: