Page 1: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

www.heatizon.com

HEATIZON SYSTEMS RADIANT HEATING AND SNOW MELTING SYSTEMS

© 2013 Heatizon Systems

Page 2: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

TABLE OF CONTENTS

Comments & Suggestions Intro 1 Floorizwarm Heating System Components Intro 2

System Description Intro 3 Applications & Sizing Intro 4 Warnings Intro 5

Floorizwarm Warranty Intro 6 Installation Instructions 1-1 Verify Proper System Sizing 1-1 Locate Power Unit, Thermostat and Floor Sensor 1-2 Electrical Service Requirements 1-2 Install Floorizwarm Tuff Cable Heating Element 1-3 Install Temperature Floor Sensor 1-5 Install Floorizwarm Power Unit Back Plate 1-6 Make Floorizwarm Power Unit Connections 1-7 Install Floorizwarm Thermostat 1-8 Cover the Tuff Cable 1-8 Technical Information 2-1 Floorizwarm Wiring Diagram 2-1 Thermostat Instructions 2-2 Sample Layout and Diagrams 2-5 Trouble-Shooting Procedures 3-1 After Installation of Element Test 4-1

Page 3: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer
Page 4: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

Dear Installer:

Heatizon Systems welcomes and appreciates any and all comments and suggestions that you

may have regarding our products, installation instructions and techniques, and applica-

tions. Please take a few minutes to share your comments and suggestions with us.

Thank you in advance for the time you will spend in helping us improve our products in the

future.

Warm Regards,

Heatizon Systems

4137 South 500 West

Murray, UT 84123

Phone: (801) 293-1232

Fax: (801) 293-3077

Email: [email protected]

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

Name: ________________________________________________________________________

Address: _____________________________________________________________________

City: _______________________________ State: ______________ Zip Code: ____________

Telephone: _______________________________ Fax: ________________________________

Email Address: ________________________________________________________________

COMMENTS AND SUGGESTIONS

Intro-1

Page 5: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

Congratulations on your purchase of the Floorizwarm Heating System, which utilizes state-of-the-art components and low-voltage electricity to provide

products that are easy to operate, virtually maintenance free, safe, and 99% efficient. The Floorizwarm Tuff Cable heating element has a limited 25-year warranty and is engineered to provide simple, problem-free, long term solutions to floor warming and space heating needs. Heatizon Systems has been “Warming America’s Cold Spots” since 1979.

Activation Device M337 Programmable

Thermostat comes with remote bulb sensor and

15 feet of cable

Heated Area

Cold Leads, 20’

The Power Unit

Floorizwarm Tuff Cable Heating Element Tuff Cable, a durable coated copper cable, is installed IN something, like concrete, thinset, or other mortar applica-tions. This system is perfect for bathroom floors or other

small areas of 15 to 110 square feet.

Line Voltage from Dedicated

Breaker

Intro-2

Temperature Floor Sensor

12/2 Wire

12/2 Wire

Page 6: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

SYSTEM DESCRIPTION

Intro-3

System Information—The Floorizwarm System is a low voltage, resistance type heating system which is ideal for

floor warming and space heating in areas 110 square feet and smaller. Floorizwarm Systems are designed to deliver approximately 10 to 15 watts per square foot, and to cover 15 to 110 square feet of floor area. A Floorizwarm System consists of three primary components:

1. The Power Unit— The Floorizwarm Power

Unit includes a step-down transformer and other elec-tronic components necessary to provide low-voltage electricity to the heating element. It is engineered to provide simple and problem free operation.

2. The Heating Element— The Floorizwarm

Heating Element is a durable coated copper cable that is chemical and gasoline resistant. Floorizwarm Heating Element (referred to herein as both “Floorizwarm Heating Element” and “Tuff Cable”) comes in various lengths and gauges, depending on system size and area to be heated. The Floorizwarm Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer.

3. Activation Device— The Floorizwarm System is activated by an M337 Programmable Ther-

mostat which includes a remote bulb sensor with 15' of cable. This thermostat requires 120 VAC power to operate. The thermostat provides a digital readout, and can be used in auto mode or man-ual mode.

Design Information—Heatizon Floorizwarm system is a low-voltage electric radiant heating system. Installations

include: concrete, light-weight concrete or mortar bed Heatizon Heatsink Kit Floorizwarm utilizes AC power supply for various sized heating applications. Floorizwarm Heating Element is designed to be spaced at specific intervals and lengths to produce a specified amount of heat per square foot. Floorizwarm Heating Element must always be installed in a heat sink, such as concrete, light-weight concrete or mortar bed, or a Heatizon Heatsink Kit. The heat density per square foot of the Floorizwarm System is dependent on the spacing between adjacent runs of Floorizwarm Heating Element, the length of the heating element, and the size of the Power Unit.

Model # Power Unit Dimensions

FLZ1520AC 8.25”H x 6.5”W x 4.75”D

FLZ2030AC 8.25”H x 6.5”W x 4.75”D

FLZ3536AC 8.25”H x 6.5”W x 4.75”D

FLZ3650AC 8.25”H x 6.5”W x 4.75”D

FLZ5064AC 8.25”H x 6.5”W x 4.75”D

FLZ6475AC 9.75”H x 7.5”W x 6”D

FLZ75110AC 9.75”H x 7.5”W x 6”D

Page 7: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

SPACE HEATING Floorizwarm products can provide total space heating. Like all other space-heating products, heat-loss calculations should be performed prior to selecting the appropriate Floorizwarm Sys-tem. Heat-loss calculations define the amount of heat which must be delivered in order to heat the given space. Heatizon Systems Floorizwarm products are suitable for installa-tion under most floor coverings. FLOOR WARMING Floorizwarm products can be used in conjunc-tion with a primary heat source to provide warm floors or supplemental heat. Floor warming ap-plications typically provide approximately 10 to 15 Watts per square foot. Heatizon Systems Floorizwarm products are suitable for installa-tion under most floor coverings. SYSTEM SIZING INFORMATION The adjacent table indicates the Floorizwarm packages that are available. Each Floorizwarm package contains a pre-measured length of Floorizwarm Heating Element with attached Cold Lead, the appropriate sized Power Unit, and a Programmable Thermostat with Floor Sensor. ELECTRICAL SERVICE REQUIREMENTS The Floorizwarm Power Unit requires an input of 120 VAC. INSULATION Properly installed insulation is always recom-mended by Heatizon to enhance the efficiency and improve the performance of all Heatizon Systems products.

APPLICATIONS & SIZING

Intro-4

Floorizwarm is configured and packaged in the seven different area sizes listed above. Floorizwarm comes complete with a pre-measured length of the appropri-ate gauge Floorizwarm Tuff Cable Heating Element, which is attached to the floor prior to the application of mortar. The Tuff Cable spacing is varied to fit a spe-cific area within the intended range of sizes. One non-heating Cold Lead is spliced to each end of the Tuff Cable Heating Element at the factory. Each Cold Lead is run to the power unit by the installer. Cold Leads are connected to the appropriate Transformer wires using wire nut connectors.

Model

Number

Area to be

Heated

Cable length

Ele-ment Spac-

ing

Watts Per

Square Foot

FLZ1520AC

15 ft2 to

20 ft2

50 feet

3.6" to

5.0“

14.7 to 11.03

FLZ2030AC

20 ft2 to

30ft2

80 feet

2.5" to

3.5“

14.9 to

9.9

FLZ2536AC

25 ft2 to

36 ft2

70 feet

3.8" to

5.5“

14.8 to

10.3

FLZ3650AC

36 ft2 to

50 ft2

160 feet

2.7" to

3.5“

14.7 to

10.6

FLZ5064AC

50 ft2 to

64 ft2

125 feet

4.8" to

6.1“

13.5 to 10.59

FLZ6475AC

64 ft2 to

75 ft2

260 feet

2.8" to

3.3“

14.9 to 12.99

FLZ75110AC

75 ft2 to

110ft2

225 feet

3.7" to

5.5“

14.8 to

10.5

SYSTEM SIZING INFORMATION SYSTEM APPLICATION INFORMATION

Page 8: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

Check contents of all boxes immediately upon receipt of your Heatizon shipment and notify Heatizon within 24 hours of any discrepancy or missing part. Read this Installation Manual in its entirety before attempting to install any Heatizon Systems Products. Installation of Heatizon Systems products and associated work must be performed by qualified persons and conform to local building codes, ordinances, trade practices, and in accordance with all applicable sections of the National Electric Code (NEC). Risk of fire! Risk of fire possible if installation of system is not completed according to all of the installation in-structions contained within this Installation Manual, including but not limited to the warnings and notes through-out. Risk of fire possible if metal or any other conductive material is allowed to come into contact with the Cold Leads and Floorizwarm Tuff Cable Heating Element. Risk of fire possible if connections/joints are not crimped and/or soldered correctly. Risk of fire possible if cuts or other damage to FloorizwarmTuff Cable are not re-paired correctly. Note: The safety features and testing procedures incorporated into Heatizon Systems prod-ucts cannot detect cuts in Cold Leads or Tuff Cable element. Do not allow Tuff Cable to touch or cross itself. Risk of shock! Make sure all power to your Heatizon Systems product and thermostat is shut off at the electric distribution panel before installing, removing covers, servicing, or working on any of the components of any Heatizon System product. All connections/joints between Colds Leads and Tuff Cable heating element must be embedded into mortar, asphalt, or other acceptable cementitious Heatsink.

Obtain written approval from Heatizon Systems for applications and installations that are different from those described herein. In order for your Heatizon Systems product to operate correctly, the transformer portion of the Control Unit must be installed so that it can dissipate the heat that it generates Like all electric products, Heatizon Systems products create a magnetic field that may interfere with certain brands of televisions, computer monitors, etc. Unlike Cathode Ray Tubes (“CRT”), Plasma Display Panels (“PDP”) and Liquid Crystal Displays (“LCD”) do not seem to be affected by magnetic fields. In the event magnetic field interference is a concern for you please consult Heatizon Systems or your sales representative prior to making your purchase. Mattresses, Bean Bag Chairs, LoveSacs, Futons, and all other items which have high insulating values should never be placed directly on any surface which has a radiant heating product under it.

Never install Heatizon Systems products in space heating or floor warming applications to deliver more than the 15 watts per square foot (or 160 watts/m

2) recommended by the Radiant Panel Association.

Field installed wiring must be in compliance with the National Electrical Code (NFPA-70) and/or ordinances, or all local building codes and trade practices.

WARNINGS

Intro-5

Please call Heatizon Systems Technical Support Department at (801) 293-1232 with any questions you have re-garding these Design and Installation Instructions and The Customer Information Sheet, or the installation, opera-tion, and maintenance of Heatizon Systems products.

Page 9: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

HEATWAVE SYSTEMS LIMITED WARRANTY

Twenty-five Year Limited Warranty for Heatizon Systems Floorizwarm AC and

Specified Radiant Panel Heating Components Heatizon Systems warrants to the end users of the following products that for the periods noted such products shall be free from defects in material and workmanship: Floorizwarm Cable Heating Element (E101-14) for a period of twenty-five (25) years, the Control Box Transformer for a period of five (5) years, and the Activation Device(s) for a period of one (1) year. Such warranty periods shall commence on the date of shipment by Heatizon Systems. If any parts are found to be defective in manufacture material or workmanship during such time period, Heatizon Systems will, at its sole option, replace or repair defective parts. This Limited Warranty applies only if articles sold hereunder (a) are selected, designed, and installed according to instruction and operation manuals furnished by Heatizon Systems and installed in a "workmanlike manner" according to the building association standards adopted by Heatizon Systems, (b) remain in their originally in-stalled location, (c) are connected to proper power supplies, (d) are not misused or abused, (e) show no evi-dence of tampering, mishandling, neglect, accidental damage, modifications or repair without the approval of Heatizon Systems, or damage done to the product by anyone other than Heatizon Systems, and (f) are installed in accordance with applicable code requirements. Any warranty claims must be made in writing, no later than one (1) month following expiration of the warranty period, and must be accompanied by the warranted part or component. Any claim not made in such manner shall not be honored by Heatizon Systems. This Limited Warranty does not cover:

DISCLAIMER OF WARRANTIES:

This warranty described above is in lieu of all other warranties, express or implied, including but not lim-ited to any implied warranties of fitness for a particular purpose and merchantability. Heatizon Systems expressly disclaims and excludes any liability for losses, expenses, inconveniences, consequential, in-cidental, indirect, or punitive damages for breach of any express or implied warranty. By installing Heatizon Systems products, you accept the terms of this limited warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so the above limitations and exclusions may not apply to you. This Limited Warranty gives you specific legal rights, and you may also have other rights, which may vary, from state to state.

1. The workmanship of any installer of Heatizon Systems products. 2. Any Heatizon Systems products that have a failure or malfunction resulting from improper or negligent operation, installation, accident, abuse, misuse, unauthorized alteration or improper repair or maintenance. 3. Any Heatizon Systems products that have had components not purchased from Heatizon Sys-tems integrated into or connected to them. 4. Any labor costs for removal of alleged defective part(s) and/or reinstallation of replacement part(s), transportation to and from Heatizon Systems (if necessary) and any other material necessary to perform the exchange or repair. 5. Any Heatizon Systems heating products that have not been properly registered by completion and return of the Warranty Registration Card provided with your product.

Intro-6

Page 10: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

INSTALLATION INSTRUCTIONS

A. VERIFY PROPER FLOORIZWARM SYSTEM SIZING

1-1

The Floorizwarm Tuff Cable Heating Element comes in pre-established lengths that have been designed to deliver a specified heat density. Therefore, it is essential that ALL of the Floorizwarm Tuff Cable Heating Ele-ment contained in your kit be installed. To insure that the Floorizwarm Model you have purchased is the cor-rect size for your project, complete this simple worksheet prior to beginning the installation process.

STEP 1. STEP 2. STEP 3. STEP 4. STEP 5.

Calculate Square Footage. Determine the square footage of the area to be warmed. Enter the total square footage on line A. Determine Watts Per Square Foot. Determine the Watts per square foot that you will need for your application. Heatizon Systems suggests the following Watts per square foot: Floor Warming—7.5 to 15 Watts per square foot Space Heating—Watts per square foot and spacing between element runs should be determined by a heat loss calculation. Contact Heatizon Systems for information on how to obtain a heat loss calculation. Enter the desired total Watts per square foot on Line B. Calculate Total Watts. Calculate total Watts by multiplying Line A by Line B, and enter the result on Line C. Select the Correct Floorizwarm Model. Select the Floorizwarm model that will deliver the total watts calculated in Step 3. Heatizon Systems recommends that you select the next larger Floorizwarm Model if the total Watts calculated in Step 3 is between two models. Check the model number, and write the corresponding “Length of Element” on Line D. Floorizwarm Model Total Watts Length of Element Floorizwarm 1520 228 50 feet Floorizwarm 2030 324 80 feet Floorizwarm 2536 360 70 feet Floorizwarm 3650 528 160 feet Floorizwarm 5064 688 125 feet Floorizwarm 6475 980 260 feet Floorizwarm 75110 1204 225 feet Calculate Element Spacing. Calculate the amount of space Between the runs of element for your application and the Floorizwarm Model you have selected. Note that spacing between element runs should not exceed 6 inches. Enter the element spacing on Line E. ____________ ÷ _____________ x 12 = _______________ Square footage Length of Element Spacing From Line A Element from (Enter on Line E) Above Line D Above

Line A ________________ (Square Footage)

Line B ________________ (Watts per Square Foot)

Line C ________________ (Total Watts)

Line D ________________ (Length of Element)

Line E __________ inches (Element Spacing)

This worksheet should confirm that you have purchased the correct Floorizwarm model, and also assist you in the installation process by determining the amount of spacing between that should be placed between element runs. In the event that you have not purchased the correct Floorizwarm model, call Heatizon Systems at 888-239-1232, or contact your Heatizon Distributor.

Page 11: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

B. SELECT LOCATION FOR THE FLOORIZWARM POWER UNIT, THERMOSTAT, AND FLOOR SENSOR

Use the following guidelines for locating the Floorizwarm Power Unit Back Plate:

Location must be easily accessible for installation, service and maintenance. Maintain a minimum of 6 inches of clearance between the Back Plate and any ceiling, wall, floor or adjacent Back Plate. Do not locate Back Plate in an area where it will be covered. Do not place in an area where high humidity is present, or where Control Unit may be exposed to water.

Determining the placement location of the Floorizwarm Power Unit Back Plate, thermostat and remote sensor is the first step in the installation process. Do not install these components now; just determine the location where they will be installed. The placement of the Floorizwarm Power Unit back plate must allow for easy future access, good air flow, and protection from moisture. Acceptable locations include garages, basements, utili-ty rooms, or mechanical rooms. The Floorizwarm Power Unit must be located within 20 total verti-cal and horizontal feet from where the Floorizwarm Tuff Cable heating Element will begin and end. The provided thermostat should be located in a convenient loca-tion in close proximity to the area where the Floorizwarm Heating Element will be located. A single gang box is required for the in-stallation of the thermostat, and should be installed at this time. It is recommend that the floor sensor for the provided thermostat be installed at the midpoint between two runs of Floorizwarm Heating Element. This will be done at the same time the Floorizwarm Tuff Cable Heating Element is installed..

1-2

C. COMPLETE ELECTRICAL POWER REQUIREMENTS AND WIRING TO THERMOSTAT AND FLOORIZWARM POWER UNIT

The Floorizwarm Power Unit requires an input power of 120 VAC (see table below to calculate breaker requirements). One AWG #12/2 with ground wire electrical conductor must extend from the electrical distribu-tion panel to the thermostat, and another AWG #12/2 wire from the ther-mostat to the Floorizwarm Power Unit.

Run the line voltage wires the total horizontal and vertical distance from the distribution panel to the Thermo-stat, and from the Thermostat to the Floorizwarm Power Unit Back Plate in accordance with the NEC and lo-cal building codes. If there is a possibility that the wall may be sheetrocked or otherwise closed in prior to completion of the Floorizwarm installation, you may wish to install a “pull wire” as a pre-

caution to facilitate correct installation of the floor sensor and/or heating element cold leads.

To Floorizwarm Power Unit

To Electrical Distribution Panel

Pull Wire for Floor Sensor

Note: When installing Heatizon Systems products, strict compli-ance with the National Electrical Code, local Building Codes, and

Heatizon Floorizwarm System Installation Manual is essential.

Model Number Total Watts

Floorizwarm 1520 228

Floorizwarm 2030 324

Floorizwarm 2536 360

Floorizwarm 3650 528

Floorizwarm 5064 688

Floorizwarm 6475 980

Floorizwarm 75110 1204

Page 12: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

Note: When installing Heatizon Systems products, strict compliance with the National Electrical Code, local Building Codes, and Heatizon Floorizwarm Installation Manual is essential.

1-3

D. INSTALL FLOORIZWARM TUFF CABLE HEATING ELEMENT

Note: A continuous continuity check should be conducted on the Floorizwarm Tuff Cable Heating Element and all electrically conductive material prior to and during the pouring of concrete, installation of floor cov-erings, and immediately prior to energizing all Floorizwarm products. The circuit should always be open. Always complete a Heatizon systems “After Installation Element Test Form” (see forms in the back of this manual) immediately following the installation of the Floorizwarm Heating Element, immediately prior to covering the Floorizwarm Heating Element, and again just prior to energizing your Floorizwarm Power Unit.

Note: In order to minimize the risk of damage to the Floorizwarm Tuff Cable Heating Element, Heatizon Systems recommends that the Floorizwarm Tuff Ca-ble Heating Element be installed immediately prior to the installation of the thinset concrete, mortar or other cementitious material that goes over it.

Note: The Floorizwarm Tuff Cable Heating Element comes in pre-established lengths that have been designed to deliver a speci-fied heat density. Therefore, it is essential that all of the Floorizwarm Tuff Cable Heating Element contained in your kit be installed.

Begin by designing the layout of the Floorizwarm Heating Element. The design and installation of the Floorizwarm Tuff Cable Heating Element will be easier if you: Purchase the correct Floorizwarm product with the proper amount of Floorizwarm Heating Element for your project. Plan the layout of the Floorizwarm Heating Element before you begin the actual installation Begin and end the Floorizwarm Heating Element in the same area, adjacent to the location you have selected for the Floorizwarm Power Unit. Run the Floorizwarm Heating Element in evenly spaced runs parallel to each other.

SAMPLE FLOORIZWARM TUFF CABLE HEATING ELEMENT LAYOUT

Warning: Never cross the Floorizwarm Heating Element over itself, the in-floor sensor wire , or any other conductive material or wire.

Page 13: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

FLOORIZWARM TUFF CABLE HEATING ELEMENT INSTALLATION:

Make sure you have verified that you have purchased the correct Floorizwarm System to heat the area you have selected and that you have determined the correct spacing for the area you are heating, the Watts you need the system to deliver, and the size of system you purchased (see “Verify Proper Floorizwarm System Sizing”).

Plan room layout using tape measure, marking pencil, and chalk line. Lay out perimeter of area to be heated first, keeping a minimum of 3 inches from walls and or cabi-nets and the first run of element. Once the layout is complete, roll out the Floorizwarm Tuff Cable Heating Element, making sure that both ends of the heating element (where the Floorizwarm Tuff Cable Heating Element is pre-connected to the Cold Lead segment) are within 20 vertical and horizontal feet of the Power Unit location to accommodate Cold Lead length.

Tie off one Cold Lead at the location where the Floorizwarm Power Unit will be located Continue by laying out Floorizwarm Tuff Cable Heating Element on the predetermined layout, and fasten with plastic clips as de-scribed below for your floor surface.

Anchor the Floorizwarm Tuff Cable Heating Element using the Plastic Clips and nails provided in the Floorizwarm Hardware Kit to hold Floorizwarm Tuff Cable Heating Element to wood subfloors. Never use any attachment that will compromise the Floorizwarm Tuff Cable Heating

Element or its insulation in any way. Each 90E bend and each 180E turn requires two Heatizon Plastic Clips. Heatizon Plastic Clips should be spaced approximately every 24 inches along the length of the heating element. Heatizon Plastic Clips can be inserted around Floorizwarm Tuff Cable Heating Element, and secured to sub floor by hammering nail through anchor ends until both plastic tails are flat against sub floor sur-face. Repeat with each Heatizon Plastic Clip until all clips are secure.

If Floorizwarm Tuff Cable Heating Element is being installed directly on existing concrete, a Heatizon Anchoring Plug Kit may be purchased. Use a 1/4" cement drill bit to drill holes 1" deep in every location where a Heatizon Plastic Clip will be located. Install one Tuff Cable Anchoring Plug into each pre-drilled hole by tapping plugs until they are flush with the surface of the concrete. Tuff Cable Anchoring Plugs should fit tightly in pre-drilled holes. Insert Heatizon Plastic Clips around Tuff Cable ele-ment and secure by hammering nail through anchor ends directly into Tuff Cable plug, until both plastic tails of the clip are flat against the concrete and plug. Repeat with each Heatizon Plastic Clip until all clips are se-cure.

Continue laying out and anchoring Floorizwarm Tuff Cable Heating Ele-ment until complete. Make certain both ends of Cold Lead attached to the Floorizwarm Tuff Cable Heating Element return to the Power Unit lo-cation. When all of the Floorizwarm Tuff Cable Heating Element has been installed and secured, run the second Cold Lead parallel to the first Cold Lead back to the Power Unit, and secure both Cold Leads to the stud nearest the chosen location for the Power Unit.

Conduct the first After Element Installation Test at this time.

1-4

Note: All of the Floorizwarm Tuff Cable Heating Element and the connection between the Tuff Cable and Cold Lead must be surround-ed by cementitious material.

Page 14: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

Warning: Never cut or otherwise attempt to alter the length of the Floorizwarm Tuff Cable Heating Element. Always inspect the Cold Leads and the Floorizwarm Heating Element just prior to embedding in the light-weight con-crete or mortar material. In the event the Floorizwarm Tuff Cable Heating Element gets cut, nicked, or otherwise damaged it must be replaced with new Floorizwarm Heating Ele-ment with factory attached Cold Leads from Heatizon Systems. Do not use Floorizwarm Tuff Cable Heating Element that has been altered, cut, nicked or otherwise damaged in any way.

Note: Floorizwarm Tuff Cable Heating Ele-ment must not be installed in ceilings, clos-ets (floor areas that are or will be covered or obstructed by shelves, cabinets, clothing, storage items, bean bags, LoveSacs, etc.) nor over or in walls or partitions.

Note: Always allow a minimum of 1.5 inches of distance between the runs of Floorizwarm Heating Element.. Minimum, maximum and ideal spacing between Floorizwarm Tuff Cable Heating Element is determined by the size of the system purchased.

E. INSTALL THE TEMPERATURE FLOOR SENSOR

Install the floor sensor provided with the thermostat from the single gang box to the area where the heating element is installed. It is recommend that the floor sensor probe be installed at the midpoint between two runs of Floorizwarm Heating Element. The floor sensor probe portion should be secured using a plastic clip and nail on the wire just above the floor sensor probe. Run the other end of the wire through the single gang box located at the chosen thermostat location. Make sure the floor sensor probe does not come into contact with the Floorizwarm Tuff Cable Heating Element.

1-5

Page 15: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

1-6

The Floorizwarm Power Unit requires an input power of 120 VAC (see table below to calculate breaker requirements). One AWG #12/2 with ground wire electrical conductor must extend from the electrical distribution panel to the thermostat, and an-other AWG #12/2 wire from the thermostat to the Floorizwarm Power Unit. Remove the cover screws from the top and bottom of the Power Unit, remove the cover and set cover aside. Familiarize yourself with the Transformer and its associated wires. The two large black wires on top of the Transformer are labeled #3 and #4. These wires will eventually connect to the two Cold Leads coming from the Floorizwarm Tuff Cable Heating Element. The two small black wires at the bottom of the Trans-former are labeled #1 and #2, and are used to connect to the hot and common wires from the thermostat. One of these wires runs through a fuse at the bottom of the Floorizwarm Power Unit back plate. The green wire is used to ground electrical connec-tion for the Floorizwarm System. Install Romex Connectors into two of the pre-drilled holes or knock outs in the Floorizwarm Power Unit back plate. One of the upper pre-drilled holes or knock outs will be used for the Cold Leads, and one of the lower pre-drilled holes or knock outs for the primary power. Push through the back to the front, and tighten down the locking nut on the front of back plate. Using the provided #8 panhead screws, mount the Floorizwarm Power Unit back plate onto a stud or other adequate surface. The Power Unit should be mounted using the two designated holes in the center of the Floorizwarm Power Unit back plate. Note: The two holes in the upper corners of the back plate may also be used for mounting if needed. Run the #12/2 electrical conductor wire through the bottom hole

E. INSTALL THE FLOORIZWARM POWER UNIT

F. INSTALL THE FLOORIZWARM POWER UNIT BACK PLATE

Note: Make certain power supply is off before proceeding with installation of the Floorizwarm Power Unit.

Page 16: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

1-7

with Romex Connector. Trim end of #12/2 to needed length, and strip 4” to 5” of plastic insulation from the protruding end of the wire. This will expose three wires: a copper ground wire, a white common line and a black hot line. Run both Cold Leads through the top hole with Romex Con-nector. Trim the end of both Cold Leads to needed length and strip approximately 1” of insulation from the end of each Cold Lead. Locate the green ground wire, located at the bottom side of the Transformer, and strip approximately 1” of insulation from the end of the wire. Using one of the provided yellow wire nuts, connect the bare copper wire from the 12/2 electri-cal conductor to the end of the green ground wire. Trim end of the large black transformer wires (# 3 and #4) to the appropriate length. Strip approximately 1” of insulation from the end of the white common line and black hot line, as well as the four black wires coming from the transformer ( line #1, #2, #3, and #4) Connect the black hot line from the #12/2 to the line that contains the fuse (small transformer line #1) using a yellow wire nut, Connect the white common line from the #12/2 to small transformer line #2 using a yellow wire nut.. Connect one large transformer wire (#3) to one of the Cold Lead ends and the other large transformer wire (#4) to the other Cold Lead end, using blue wire nuts. Tuck the wires in and replace the Power Unit cover. All con-nections must be contained inside the Floorizwarm Power Unit. Do not allow any wire to be pinched between the back plate and the cover. Mark the appropriate circuit breaker reference label indicat-ing which branch circuit supplies the circuit to your Floorizwarm Power Unit and thermostat.

E. INSTALL THE FLOORIZWARM POWER UNIT

G. MAKE THE FLOORIZWARM POWER UNIT CONNECTIONS

Page 17: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

1-8

Note: All connections between Cold Leads and Tuff Cable must be embedded in mortar, asphalt, concrete, a Heatizon Heatsink Kit, or other acceptable ce-mentitious heat sink material.

Power the thermostat with a dedicated power supply directly from the electrical distribution panel using AWG #12-2 electrical conductor with ground wire and a 20 Amp breaker and following the thermostat manufacturer’s instructions. See the installation Instructions and diagrams that follow, or refer to ther-mostat packaging for details. Tips: The back of the thermostat has two sets of black and white wires: One pair (one black and one white on the same side of the thermostat) for the line voltage (incoming power) and one pair for load output to Floorizwarm Power Unit). Follow the diagram in the instructions, insuring that the outer black and white wires will be wired to corresponding black and white wires connecting to the Floorizwarm Power Unit, and the inner black and white wires will be wired to corresponding black and white wires connecting the thermostat to the power supply. The two copper ground wires will be connected using the wire nut (supplied with thermostat), and tucked inside the thermostat electrical gang box. Program the thermostat.

I. COVER THE TUFF CABLE

Apply enough light-weight concrete, mortar, thinset, or other cementitious material over the Floorizwarm Tuff Cable Heating Element to completely cover it in its entirety and to cover the connections of the Cold Leads and the Floorizwarm Heating Element. Conduct the third After Element Installation Test at this time.

H. INSTALL THE FLOORIZWARM THERMOSTAT

Connect to Floorizwarm Connect to Power Supply

Note: Three After Element Installation Tests should have been performed by this point in the installation.

Note: Complete and return your Warranty Registration card to Heatizon Systems.

.

Page 18: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

FLOORIZWARM WIRING DIAGRAM

2-1

Page 19: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

PB112 400-112-006-B 1/6/05 1/1

One (1) power base

Two (2) screws

Four (4) solderless connectors for copper wires NOTE: Special CO/ALR solderless connectors must be used for connectingaluminum conductors.

One (1) floor sensor and one (1) flat tip screwdriver (F and AF floor heating models only).

Turn off power to the heating system at the main electrical panel toavoid electrical shock. The installation should be carried out by an elec-trician.

High voltage thermostats must be installed onto an electrical box. For a new installation, choose a location about 5 ft. above the floor andon an inside wall.The thermostat must be installed on an inside wall facing the heatingsystem (except for floor heating systems). Avoid locations where there are air drafts (top of staircase, air outlet),dead air spots (behind a door), direct sunlight or concealed chimneys orstove pipes (except for floor heating systems).

Connect the power base wires to the power supply and load using sold-erless connectors for copper wires (figure 1).

If your thermostat is type F or AF (not A), insert the floor sensor wires through one of the two holes below the terminals (figure 2) and connect the wires to terminals 3 and 4 (no polarity).The wires must run alongside the terminals and not go over them. The wire must not cross any heating wires nor be placed directly on a heating wire or adjacent to it. For best performance, the sensor probe should be centered between the wires in the mat.

If you wish to use a remote controller such as the CT240 or CT241, insert the cable (use 18 to 22 gauge flexible wires) into one of the two holes available below the terminal board and connect to terminals 1 and 2 of the base (figure 2).Push the excess length of the high-voltage wires back into the electrical box.Secure the power base to the electrical box using the provided screws.

If necessary, set the configuration switches on the control module (refer to the control module user guide).Install the control module onto the base.

Apply power to heating system.

Storage: -4°F to 120°F (-20°C to 50°C)Remote controller input (ECONO): requires a dry contactSize (H • W • D): 4.89 x 2.76 x 0.91 in. (124 x 70 x 23 mm)

Certifications:

Parts1.

Guidelines2.

Procedure3.

Technical Specifications4.

Model Supply Max. Load Power Wiring GFCI

120GA 120 VAC, 50/60Hz 15 A 1800 W 4w/DP 5 mA

120GB 120 VAC, 50/60Hz 15 A 1800 W 4w/DP 30 mA

120S 120 VAC, 50/60Hz 16.7 A 2000 W 4w/SP

240GA 240 VAC, 50/60Hz208 VAC, 50/60Hz 15 A 3600 W

3120 W 4w/DP 5 mA

240GB 240 VAC, 50/60Hz208 VAC, 50/60Hz 15 A 3600 W

3120 W 4w/DP 30 mA

240S 240 VAC, 50/60Hz208 VAC, 50/60Hz 16.7 A 4000 W

3475 W 4w/SP

240D 240 VAC, 50/60Hz208 VAC, 50/60Hz 15 A 3600 W

3120 W 4w/DP

Power

Load

Figure 1

Figure 2

Models:120 GA / GB

240 GA / GB

Models:

120S / 240S240D

PB112Installation Instructions

For models: 120GA / 120GB / 120S / 240GA / 240GB / 240S / 240D

2-2

Page 20: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

Thank you for choosing the Aube TH115, aprogrammable thermostat that provides both energysavings and comfort.

Buttons and symbolsOn/Stand By SwitchUse this switch to put the thermostat in sleep mode when its use is no longer required (e.g. summer). This will not affect the clock or programming.GFCI Warning Light and Test ButtonDay & Clock SettingsProgramming ModeMode Selection/Exit ProgrammingRoom OR Floor TemperatureCurrent Mode and Setpoint Current Program NumberSetpoint definition/Pre-defined SetpointsIncrease/Decrease Temperature

ModelsA Controls the Ambient temperature.AF Controls the Ambient temperature and Floor temper-

ature limit. F Controls the Floor temperature.

This thermostat is factory-set to the following values: Align the bracket tabs on the control module with theholes located on top of the power base.

NOTE: Keep the thermostat's air vents clean and freefrom obstructions.NOTE: The screw cannot be removed completely.

TH115 A/F/AFOwner’s Guide

TH115 Description

# Function UP DNSW1 Temperature format a

a. If you switch from °F to °C or vice versa, the , and setpoints may need to be redefined.

°F °C

SW2 Early Start b

b. When using AUTO mode, the thermostat calculates the optimum start time to obtain the desired temperature by the set time. The heating system could be started a few hours prior to set time when required.

Disable EnableSW3 Time format 12-hour 24-hour

Switch Selection

Switches are located on the rear of the control module. To modify any setting, switch UP or DN.

Control Module Installation

Power base

Control module

When power is applied for the firsttime, the LCD displays: 0:00, MO(Monday), and temperature (room/floor).

Press HOUR - MIN to set the current time.Press DAY to set current day.

For AF and F models: one of the twofollowing messages may be displayedif the installation is incorrect:LO: The floor temperature is below

32°F (0°C), or the temperaturesensor is defective, or not con-nected. The heating indicator is dis-played and the relay is closed(energized).

HI: The floor temperature is above140°F (60°C), or the tempera-ture sensor is defective.

The GFCI monitors the electrical flow forany loss of current; if there is one, thethermostat will cut off power to the heatingsystem. We recommend you test the GFCIimmediately after installing the controlmodule, and once a month thereafter toensure it is operating properly. To test:

Increase the temperature until the heating indicator is displayed.Press TEST:• Successful: the TEST warning light is ON and

power to heating system is cut off. • Unsucessful: the TEST warning light is OFF. Cut

power to heating system from the main powerpanel and call customer service.

When successful, reset thermostat (Stand By/On) to power the heating system.

NOTE: If the test warning light comes ON during normaloperation, cut power to heating system from the mainpower panel and have an electrician verify the installation.

The following temperature setpoints are pre-programmed:

To modify a setpoint:Set the desired temperature using .Press and Hold the or or button until symbol is displayed.Press RET to exit.

Floor temperature limit—The floor temperature limit is82°F. To modify this limit:

Automatic —Executes the schedule. Press MODE until is displayed. The cur-rent program number is displayed.You can temporary bypass the current pro-gram by setting a specific temperature or by pressing on a pre-defined setpoint button ( ) . The new setpoint will be maintained until the begin-ning of the next program.

Manual —Maintains a constant temperature.Press MODE until is displayed.Set temperature or press ( ) to use pre-defined setpoint.

Vacation —Maintains the Vacation setpoint during a prolonged absence.

Press until the icon is displayed.

Correct

Incorrect

First Power ON GFCI Test (GA & GB power base only)

Symbol Description Default New

Comfort (when at home) 70°F 82°F

Economy (when asleep/away from home) 64°F 68°F

Vacation (during prolonged absence) 50°F 50°F

Temperature Setpoint

Press and hold while switching from ON to Stand By then back to On.

Set temperature Press RET to exit.

To avoid damaging your floor, werecommend you follow thesupplier’s instructions.

Operating Modes

920-115-007-00-1-A

A/AF F

Page 21: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

The TH115 programmable thermostat is pre-programmedwith the following schedule:

Notes:You can program up to 4 different programs per day.Each day can have different programs.It is sometimes faster to program the same schedulefor the entire week and then to modify the exceptiondays.

To modify:Press PGM to access the programming modePress DAY to select the day to be programmed (hold for 3 seconds to select all days of the week).Press PGM to select the program number.Press HOUR and MIN to set the time or press CLEAR to clear the time (--:-- is disregarded).Repeat steps 2 to 4 for remaining programs.When completed, press RET to exit mode.

NOTE: After 60 seconds of inactivity, the thermostat willautomatically exit programming mode.

Custom GridUse this blank grid to record your new schedule.

Model: A F AFTemperature display: °F °CTime display: 12hrs 24hrs

The TH115 is equipped with a remote input which allowsconnection of a telephone controller (accessoryAube CT240) or any other remote control system. When a signal is received through this input, the TH115will automatically switch from normal operating mode toVacation mode ( ), and vice versa when the signal isremoved.

Activating the Vacation mode There are two ways to activate the Vacation mode:

From the thermostat, see “Operating Modes” above.From a telephone (remote location). For details on how to activate using a telephone, refer to the CT240 Instruction Manual.

WARNING: When the Vacation mode is activatedremotely, it must be deactivated remotely. Programs MO TU WE TH FR SA SU

6:00 6:00 6:00 6:00 6:00 6:00 6:00

8:30 8:30 8:30 8:30 8:30 --:-- --:--

16:00 16:00 16:00 16:00 16:00 --:-- --:--

23:00 23:00 23:00 23:00 23:00 23:00 23:00

Pre-programmed Schedule

Time you wake up and

desired temperature

Time you leave and

temperature during your

absence

Time you return home and desired temperature

Time you go to bed and overnight

temperature

Modify the Schedule

Prog Setpoint MO TU WE TH FR SA SU

Remote Input

Temperature Control

The TH115 thermostat works differently than conventionalelectromechanical thermostats. It is equipped with a proportional integral adaptive (P.I.A.)controller which determines heating cycles by analyzingthe temperature behavior history within the room.The P.I.A. controller reduces temperature variationsproviding an accurate temperature control whileincreasing user comfort.The controller determines the amount of power requiredby the heating system to maintain the setpointtemperature.

Technical Specifications

Model: TH115 A / AF / FDisplay range: 32°F to 140°F (0°C to 60°C)Setting range (ambient): 40°F to 86°F (5°C to 30°C)Setting range (floor limit): 40°F to 104°F (5°C to 40°C)Pre-programmed temperature setpoints:

Comfort: A/AF: 70°F (21°C) and F: 82°F (28°C)Economy: A/AF: 64°F (18°C) and F: 68°F (20°C)Vacation: A/F/AF: 50°F (10°C)Floor limit:AF: 82°F (28°C)

Accuracy:± 0.9°F (0.5°C)Storage:-4°F to 120°F (-20°C to 50°C)Temperature control: Proportional integral adaptive,15-minute or 15-second heating cycles according to theapplication and power base. Memory backup: In the event of a power failure, aninternal circuit will maintain the programming. Only thetime will have to be set if the power failure is more thantwo (2) hours. The thermostat will return to the sameoperating mode as set before the power failure.

WarrantyAUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTYThis product is guaranteed against workmanship defects for aone year period following the initial date of purchase. During thisperiod, AUBE Technologies Inc. will repair or replace, at ouroption and without charge, any defective product which has beenused under normal conditions.The warranty does not cover delivery costs and does not apply toproducts poorly installed or randomly damaged followinginstallation.This warranty cancels and replaces any other manufacturer'sexpress or implied warranty as well as any other companycommitment. AUBE Technologies Inc. cannot be held liable forrelated or random damages following the installation of thisproduct.The defective product as well as the purchase invoice must bereturned to the place of purchase or mailed, prepaid and insured,to the following address:

Aube Technologies Inc. 705 Montrichard Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8

1 to 20% 21 to 40% 41 to 60% 61 to 80% 81 to 100%

As an ENERGY STAR® partner, Aube Technologies has determined that this product meets the ENERGY STAR

guidelines for energy efficiency.

04/08/2003 920-115-007-00-1-A

If you have any questions concerning theinstallation or programming of the TH115programmable thermostat, call our technicalsupport team at:

Phone: Montreal area:(450) 358-4600Canada / U.S.:1-800-831-AUBE (2823)

Fax: (450) 358-4650Email: [email protected]

Monday to Friday from 8:30 AM to 5:00 PM EST

For more information on our products, visit us at:www.aubetech.com

Page 22: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

FLOORIZWARM HEATING ELEMENT

DO NOT CUT OR DAMAGE FLOORIZWARM HEATING ELEMENT OR IT’S INSULATOR IN ANY WAY

FLOORIZWARM HEATING ELEMENT UNDER TILE/STONE ON CONCRETE SLAB

FLOORIZWARM HEATING ELEMENT UNDER TILE STONE WITH LATHE ON WOOD SUBFLOOR

WARNING: DO NOT CUT OR DAMAGE FLOORIZWARM HEATING ELEMENT OR IT’S INSULATOR IN ANY WAY.

PROVIDE MUD SEPARATION BETWEEN METAL

FLOORIZWARM HEATING ELEMENT

DO NOT CUT OR DAMAGE FLOORIZWARM HEATING ELEMENT OR IT’S INSULATOR IN ANY WAY

WARNING

FLOORIZWARM HEATING ELEMENT

FLOORIZWARM HEATING ELEMENT UNDER HARDWOOD IN LIGHT-WEIGHT CONCRETE ON

WOOD SUBFLOOR

FLOORIZWARM HEATING ELEMENT

SAMPLE FLOORIZWARM SYSTEM APPLICATION DIAGRAMS

2-5

Page 23: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer
Page 24: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

TROUBLE-SHOOTING PROCEDURES:

Problem: If the Floorizwarm Unit does not heat, and there is no power in the Floorizwarm Power Unit: Solution: • Turn circuit breaker to the “off” position. Check for proper power connection to the Power Unit. • Turn circuit breaker to the “off” position. Check all connections in control unit. • Check that the 20 amp circuit breaker panel is in the “on” position. Problem: If the Floorizwarm Unit does not heat, but there is power in the Floorizwarm Power Unit: Solution: • Check the fuse in the Floorizwarm Power Unit. • Check that the Thermostat is wired properly. • Check that the Thermostat is programmed correctly and is calling for heat. • Check for 120 VAC on primary of Transformer (line #1 and line #2). • Check for proper voltage on secondary of Transformer (line #3 and line #4). • Using a clamp on Amp meter, check for current in the heating element. If not amperage is present, turn the circuit breaker to the Power Unit to the “off” position, disconnect the Cold Lead from the Transformer, and check for continuity of the Floorizwarm Heating Element. Problem: If the circuit breaker flips: Solution: Call Heatizon systems at 801-293-1232

TROUBLE SHOOTING PROCEDURES

3-1

WARNING: HIGH VOLTAGE PRE-SENT! TROUBLE- SHOOTING PRO-CEDURES AND MEASUREMENTS MUST BE PERFORMED WITH THE SYSTEM ENERGIZED AND THE CO-VERS REMOVED. ALWAYS MAKE CERTAIN THAT THE PERSON PER-FORMING THESE PROCEDURES IS FAMILIAR WITH SAFE PRACTICES REQUIRED FOR WORKING WITH HIGH VOLTAGE EQUIPMENT. A QUALIFIED TECHNICIAN OR ELEC-TRICIAN SHOULD PERFORM THE FOLLOWING PROCEDURES!

NOTE: Always turn power off prior to re-moving or reinstalling covers.

NOTE: Prior to trouble-shooting the sys-tem, check for obvious problems such as loose connections, cut or broken wires, etc.

Page 25: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer
Page 26: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

After Installation Element Test

WARNING: This test will not detect cuts in ZMesh, Tuff Cable, or Floorizwarm Heating Element.

Attached please find three forms titled AHeatizon Systems After Installation Element Test.@ Heatizon Systems recom-mends that the measurements be taken and the attached forms be completed on all zones on three different occasions. It is im-portant that the same source be used to energize the ZMesh, Tuff Cable and Floorizwarm Heating Element for all tests taken.

• Element Test #1— should be conducted immediately after the Cold Lead and Z Mesh, Tuff Cable, or Floorizwarm Heating Element has been installed and before it has been covered up with floor covering, roofing material,

concrete, etc.

• Element Test #2 — is to be conducted following the covering of the heating element and immediately prior to installing the Control Unit.

• Element Test #3 — should be conducted immediately following the energizing of the system but prior to placing it in service.

All of these tests may be conducted by using either the Control Box and Transformer provided as part of your Heatizon

Systems Product, or by using Heatizon Systems Element Tester (Part Number NI113). It is Heatizon Systems’ recommendation that each test be completed by the party responsible for the installation and witnessed by a representative of the party which con-tracted for the installation. It is essential that all of the blanks on each AAfter Installation Element Test@ form be completely filled out and that the form be signed by both the party completing the test and the party witnessing the test.

Conducting these tests will help insure that a third party or an unknown event has not adversely impacted the heating element. In addition the results of these tests may help you in any troubleshooting that must be performed on the system(s).

Warning: In the event any of the measurements taken during the three “After Installation Element Tests” are different, a

problem may exist. Do not energize your Heatizon Systems product, and call Heatizon Systems Technical Support at

(801) 293-1232 to discuss the options available.

Element Tester Instructions

Part Number NI113 1. Connect one of the welding cable leads from the Element Tester to one of the Cold Leads near the point where the Cold Leads will eventually connect to the transformer. (Note: Cold leads are the #2 wires extending from the heating element to the transformer). 2. Connect the other welding cable lead from the Element Tester to the other Cold Lead near the point where the Cold Leads will eventually connect to the transformer. 3. Plug the Element Tester power cord into a 120 VAC power source. 4. Turn the Tester to the AON@ position.

5. Using an Amp meter, read the amperage (Amps) and Voltage (Volts) and record them on the form titled AHeatizon

Systems After Installation Element Test.@ The voltage is to be read at the connection of one of the Cold Leads and the welding cable lead from the Element Tester. Amperage can be read anywhere along either Cold Lead. 6. Read and record the temperature of the area where the heating element is located. 7. Using the numbers recorded on the form titled “Heatizon Systems After Installation Element Test” and the form titled “Calculation of Element Length,” the length of the heating element can be calculated or verified.

4-1

Note: When using the Control Box and Transformer provided as part of your Heatizon product to conduct the

“Heatizon Systems After Installation Element Tests,” the entire product must be installed per this manual. Once instal-

lation is complete, conduct three Element Tests by following steps 4 through 6 above.

Note: When hardwood or tile floor coverings are placed over ZMesh, the current may increase when the folds are

compressed. As a result of this compression, the effective length of ZMesh can decrease as much as one foot per

fold.

Note: For Tuff Cable snow melt applications, the temperature will change the current in the element. For example, the

current will increase approximately 14% as the temperature drops from 80°F to 0°F.

Page 27: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer
Page 28: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

After Installation Element Test

Test #1 Complete a separate test for each Control Unit or zone

Date: ____________________________ Current Time: _________________ This test is for Zone Number ________ of _________ (Total Number of Control Units/Zones in this system)

Length of Cold Leads including Jumpers: __________ Feet on Side 1 __________ Feet on Side 2* Number of 90º Folds

Model Serial Number Length of Heating Element (ZMesh Only) � CBX6 ____________ ________ Feet ____________ � CBX23 ____________ ________ Feet on Side 1 and _______ Feet on Side 2* ____________ � CBX7 ____________ ________ Feet ____________ � Radiant 8 ____________ ________ Feet on Side 1 and _______ Feet on Side 2* ____________ � Floorizwarm ____________ ________ Floorizwarm Model Number ____________ Type of Heating Element: � 9” ZMesh �12” ZMesh �Tuff Cable � Floorizwarm

Description of Area Covered by the Heating Element:

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

Step 1: Visually inspect the Cold Lead and Tuff Cable or ZMesh Heating Element and properly repair any and all nicks, cuts, tears, and/or other damage to the heating element or Cold Lead.

Step 2: Make certain that communication does not exist between the Cold Lead or Heating Element and any and all

electrically conductive material including but not limited to drip edge, valley metal, door thresholds, flashing, metal roofing material, metal studs, rebar, etc. In other words, identify any and all shorts, eliminate them and properly repair any and all damage to the Cold Lead or Heating Element.

Step 3: Measure and record the Primary/Input Power Amps _____ Volts _____ Step 4: Measure and record the surface temperature of the area to be heated or snow melted: ______ degrees F. Step 5: Measure and record the Secondary/Output Power being delivered by the Transformer: Side 1: Amps _____ Volts _____ Side 2*: Amps _____ Volts _____ Step 6: Measure and record the surface temperature of the area to be heated or snow melted: ______ degrees F. Step 7: Sign this form and have a witness sign this form in the appropriate space below. Test Completed by: ________________________ Daytime Telephone # ___________ ________________________ Test Witnessed by: ________________________ Dated: ________________, 20____ _________________________ *For two-sided or “dual” systems only.

4-2

Page 29: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer
Page 30: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

After Installation Element Test

Test #2 Complete a separate test for each Control Unit or zone

Date: ____________________________ Current Time: _________________ This test is for Zone Number ________ of _________ (Total Number of Control Units/Zones in this system)

Length of Cold Leads including Jumpers: __________ Feet Type of Control Unit Serial Number Length of Heating Element � CBX6 ____________ ________ Feet � CBX23 ____________ ________ Feet on Side 1 and _______ Feet on Side 2 � CBX7 ____________ ________ Feet � Floorizwarm ____________ ________ Floorizwarm Model Number Type of Heating Element: � 9” ZMesh �12” ZMesh �Tuff Cable � Floorizwarm

Description of Area Covered by the Heating Element:

_______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

Step 1: Visually inspect the Cold Lead and Tuff Cable or ZMesh Heating Element and properly repair any and all nicks, cuts, tears, and/or other damage to the heating element or Cold Lead.

Step 2: Make certain that communication does not exist between the Cold Lead or Heating Element and any and all

electrically conductive material including but not limited to drip edge, valley metal, door thresholds, flashing, metal roofing material, metal studs, rebar, etc. In other words, identify any and all shorts, eliminate them and properly repair any and all damage to the Cold Lead or Heating Element.

Step 3: Measure and record the Primary/Input Power Amps _____ Volts _____ Step 4: Measure and record the surface temperature of the area to be heated or snow melted: ______ degrees F. Step 5: Measure and record the Secondary/Output Power being delivered by the Transformer: Amps _____ Volts _____ Step 6: Measure and record the surface temperature of the area to be heated or snow melted: ______ degrees F. Step 7: Sign this form and have a witness sign this form in the appropriate space below. Test Completed by: ________________________ Daytime Telephone # ___________ ________________________ Test Witnessed by: ________________________ Dated: ________________, 200__ _________________________

Date: ____________________________ Current Time: _________________ This test is for Zone Number ________ of _________ (Total Number of Control Units/Zones in this system)

Length of Cold Leads including Jumpers: __________ Feet on Side 1 __________ Feet on Side 2* Number of 90º Folds

Model Serial Number Length of Heating Element (ZMesh Only) � CBX6 ____________ ________ Feet ____________ � CBX23 ____________ ________ Feet on Side 1 and _______ Feet on Side 2* ____________ � CBX7 ____________ ________ Feet ____________ � Radiant 8 ____________ ________ Feet on Side 1 and _______ Feet on Side 2* ____________ � Floorizwarm ____________ ________ Floorizwarm Model Number ____________ Type of Heating Element: � 9” ZMesh �12” ZMesh �Tuff Cable � Floorizwarm

Description of Area Covered by the Heating Element:

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

Step 1: Visually inspect the Cold Lead and Tuff Cable or ZMesh Heating Element and properly repair any and all nicks, cuts, tears, and/or other damage to the heating element or Cold Lead.

Step 2: Make certain that communication does not exist between the Cold Lead or Heating Element and any and all

electrically conductive material including but not limited to drip edge, valley metal, door thresholds, flashing, metal roofing material, metal studs, rebar, etc. In other words, identify any and all shorts, eliminate them and properly repair any and all damage to the Cold Lead or Heating Element.

Step 3: Measure and record the Primary/Input Power Amps _____ Volts _____ Step 4: Measure and record the surface temperature of the area to be heated or snow melted: ______ degrees F. Step 5: Measure and record the Secondary/Output Power being delivered by the Transformer: Side 1: Amps _____ Volts _____ Side 2*: Amps _____ Volts _____ Step 6: Measure and record the surface temperature of the area to be heated or snow melted: ______ degrees F. Step 7: Sign this form and have a witness sign this form in the appropriate space below. Test Completed by: ________________________ Daytime Telephone # ___________ ________________________ Test Witnessed by: ________________________ Dated: ________________, 20 ____ _________________________ *For two-sided or “dual” systems only.

4-3

Page 31: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer
Page 32: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

After Installation Element Test

Test #3 Complete a separate test for each Control Unit or zone

Date: ____________________________ Current Time: _________________ This test is for Zone Number ________ of _________ (Total Number of Control Units/Zones in this system)

Length of Cold Leads including Jumpers: __________ Feet Type of Control Unit Serial Number Length of Heating Element � CBX6 ____________ ________ Feet � CBX23 ____________ ________ Feet on Side 1 and _______ Feet on Side 2 � CBX7 ____________ ________ Feet � Floorizwarm ____________ ________ Floorizwarm Model Number Type of Heating Element: � 9” ZMesh �12” ZMesh �Tuff Cable � Floorizwarm

Description of Area Covered by the Heating Element:

_______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

Step 1: Visually inspect the Cold Lead and Tuff Cable or ZMesh Heating Element and properly repair any and all nicks, cuts, tears, and/or other damage to the heating element or Cold Lead.

Step 2: Make certain that communication does not exist between the Cold Lead or Heating Element and any and all

electrically conductive material including but not limited to drip edge, valley metal, door thresholds, flashing, metal roofing material, metal studs, rebar, etc. In other words, identify any and all shorts, eliminate them and properly repair any and all damage to the Cold Lead or Heating Element.

Step 3: Measure and record the Primary/Input Power Amps _____ Volts _____ Step 4: Measure and record the surface temperature of the area to be heated or snow melted: ______ degrees F. Step 5: Measure and record the Secondary/Output Power being delivered by the Transformer: Amps _____ Volts _____ Step 6: Measure and record the surface temperature of the area to be heated or snow melted: ______ degrees F. Step 7: Sign this form and have a witness sign this form in the appropriate space below. Test Completed by: ________________________ Daytime Telephone # ___________ ________________________ Test Witnessed by: ________________________ Dated: ________________, 200__ _________________________

Date: ____________________________ Current Time: _________________ This test is for Zone Number ________ of _________ (Total Number of Control Units/Zones in this system)

Length of Cold Leads including Jumpers: __________ Feet on Side 1 __________ Feet on Side 2* Number of 90º Folds

Model Serial Number Length of Heating Element (ZMesh Only) � CBX6 ____________ ________ Feet ____________ � CBX23 ____________ ________ Feet on Side 1 and _______ Feet on Side 2* ____________ � CBX7 ____________ ________ Feet ____________ � Radiant 8 ____________ ________ Feet on Side 1 and _______ Feet on Side 2* ____________ � Floorizwarm ____________ ________ Floorizwarm Model Number ____________ Type of Heating Element: � 9” ZMesh �12” ZMesh �Tuff Cable � Floorizwarm

Description of Area Covered by the Heating Element:

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

Step 1: Visually inspect the Cold Lead and Tuff Cable or ZMesh Heating Element and properly repair any and all nicks, cuts, tears, and/or other damage to the heating element or Cold Lead.

Step 2: Make certain that communication does not exist between the Cold Lead or Heating Element and any and all

electrically conductive material including but not limited to drip edge, valley metal, door thresholds, flashing, metal roofing material, metal studs, rebar, etc. In other words, identify any and all shorts, eliminate them and properly repair any and all damage to the Cold Lead or Heating Element.

Step 3: Measure and record the Primary/Input Power Amps _____ Volts _____ Step 4: Measure and record the surface temperature of the area to be heated or snow melted: ______ degrees F. Step 5: Measure and record the Secondary/Output Power being delivered by the Transformer: Side 1: Amps _____ Volts _____ Side 2*: Amps _____ Volts _____ Step 6: Measure and record the surface temperature of the area to be heated or snow melted: ______ degrees F. Step 7: Sign this form and have a witness sign this form in the appropriate space below. Test Completed by: ________________________ Daytime Telephone # ___________ ________________________ Test Witnessed by: ________________________ Dated: ________________, 20____ _________________________ *For two-sided or “dual” systems only.

4-4

Page 33: HEATIZON SYSTEMS - Global Industrial · Heating Element is factory-connected to non heating Cold Leads, which are 20 feet long, and are connect-ed to the Power Unit by the installer

Heatizon Systems 4137 South 500 West Murray, UT 84123

Phone: 801-293-1232 Fax: 801-293-3077 The Heatizon Family of Products

COMMERCIAL, RESIDENTIAL & INDUSTRIAL APPLICATIONS

The Control Unit (Low Voltage Only) The Heatizon Control Unit is the

“brains” of the system, and houses the necessary electrical components to provide low voltage electricity to the

heating elements. Because the largest Control Unit is only

17” x 12” x 9”, it can be mounted easily on a garage, utility room

or mechanical room wall.

www.heatizon.com © 2013 Heatizon Systems

Snow Melting—Retrofit Tuff Cable or Hott-Wire Heating Element is installed in saw cuts in existing concrete or asphalt; cuts are then filled with sealant.

Snow Melting—New Pour Tuff Cable or Hott-Wire Heating Element is installed in concrete,

asphalt, or under pavers for safe and convenient snow melting solutions.

Snow Melting—Stairs & Sidewalks Tuff Cable or Hott-Wire Heating

Element is installed in sidewalks and stairs, access ramp, in/under

concrete, asphalt, or under pavers.

Floor Warming/Total Space Heating Tuff Cable or Cozy Heat is installed in

concrete of basement (or on a con-crete or wood subfloor embedded in a cementitious material) directly under carpet, tile, hardwood, and laminate

floorings.

Floor Warming/Space Heating ZMesh Heating Element is installed

on a wood or concrete subfloor under carpet, laminate flooring, hardwood, or tile. Two or more smaller rooms can easily be “jumpered” together to heat multiple areas with one system.

Roof De-icing—Non Metal Roofing ZMesh Heating Element is easily installed under most non-metallic roof coverings,

including asphalt, shake, or tile shingles to provide “invisible” eave and valley ice melting

and prevention of snow build up and ice

Roof De-icing—Metal Roofing Tuff Cable Heating Element is installed in a Patented Heatizon Heatsink Kit or

Heatizon Invizimelt Kit when metal roofing materials are used.

Roof and Gutter Deicing Heatizon GutterMelt is installed on top of roofing material on eaves, and in rain gut-ters, drains and downspouts to control ice

dams and maintain drainage paths.