Page 1: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

H E L E N A L A B O R ATO R I E S

P R O D U C T H I G H L I G H T S

2 0 1 9

549-3025/19

[email protected]

Page 2: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Innovation for Science. That’s been Helena’s mission statement since the company was founded and the driving force behind our Focus Group Road Tour. Input from real-world laboratorians like you is helping Helena continue to solve real-world problems today.

• Participants at the 2018 Milwaukee and Chicago meetings asked if our SPIFE Anti-Dara* antiserum, developed to remove the effect of Daratumumab from blood specimens for SPE and IFE testing, might also be used to eliminate the cross-reactive interference that Blood Banks see. That started an investigation and today our Anti-Dara is in clinical trials for transfusion medicine as well as in the approval process for SPE and IFE.

• An attendee from Mississippi presented a novel idea for handling fibrin in serum specimens from cancer patients. Thrombin Drops are in the works!

• Another lab was seeing a big increase in Alpha 1 Antitrypsin testing. We now have a pre-submission of SPIFE A1AT* with higher sensitivity and over twice the throughput of existing methods.

• Also, a more robust v2 of our Myeloma Module for reporting SPE and IFE results is now available and v3 is in the works. Our Touch System continues to be the frontrunner in zone electrophoresis and we’re responding to requests for higher capacity capillary testing with the new Nexus MAX with a throughput of 552 SPE in six hours.

This catalog highlights many of Helena’s flagship products today – and a peak into the future. But the work doesn’t stop here. If you have a problem in the laboratory or an idea that could make your job easier, bring it to us! We are eager to listen and put our best work into meeting the needs of today’s laboratory.

Best personal regards,

Tipton Golias

2 0 1 9

TA B L E O F C O N T E N T S

TOUCH SERIES .....................................3-13ESH Touch ................................................................5SPIFE Touch .........................................................6-9QuickScan Touch .........................................10-11QuickGels .......................................................12-13

SPIFE 4000 .........................................14-18

V8 NEXUS ..........................................19-23

HEMOSTASIS .....................................24-32Plateletworks ...................................................... 25Actalyke XL .......................................................... 26Cascade Abrazo ............................................27-28AGGRAM .........................................................29-30Cascade M4....................................................31-32

FOBT / PLASTICS ...............................33-37Occult Blood ..................................................34-35Plastics .............................................................36-37

*For research use only. June 2019

Page 3: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

HelenaThe Nexus MAX features eight capillaries and six on-board reagent positions that enable full multi-assay functionality and high throughput. A superior sample handling system allows continuous loading of samples with auto-dilutions and auto-preparation of SPIFE sample trays for additional testing by gel electrophoresis.

IFE of Patient on Daratumumab Therapy

• Added to patient sample cup prior to application to bind up the therapeutic monoclonal, removing confusion with pathologic monoclonals

• Expandable to other monoclonal antibody (MAB) drugs like elotuzumab

NEXUS MAX | AUTOMATED CLINICAL CHEMISTRY ANALYZER

SPIFE ANTI-DARA* ALPHA-1 ANTITRYPSIN*

P R O D U C T P R E V I E W S 2

Before SPIFE Anit-Dara

WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS

After SPIFE Anit-DaraS N E A K P E A K !

AT T E N T I O N B L O O D B A N K E R S !

SPIFE Alpha-1 Antitrypsin

• American Lung Association recommends all individuals with COPD or emphysema be tested for Alpha-1 Antitrypsin deficiency

• SPIFE Alpha-1 AT assay separates up to 40 samples per gel

• Identifies all genotypes clinically relevant to lung and liver disease

Anti-Dara also removes interference with antibody screens

*For research use only. June 2019

Labcon D I S P O S A B L E P L A S T I C S 3 7

D I S P O S A B L E L A B WA R E P L A S T I C S

NEW! URINESAFE URINE COLLECTION CUP Gasket for

leak resistance

Finally, a urine cup that can withstand a pneumatic tube

transfer system without springing a leak or breaking the

bank! Those are two of the design specifications of this

new specimen cup now available from Labcon.

Taking cues from their expertise with centrifuge tubes, a

gasket integrated in the lid provides a tight, leak-resistant

seal. High-quality plastic and precision engineering

mean the cup won't shatter during transfer and the

threads mesh cleanly and smoothly allowing the lid to be

screwed on easily.

90 mL, Non-Sterile (100 cups)Cat. No. 4111-840-000-990 mL, Sterile (100 individually wrapped cups)Cat. No. 4111-165-000-9120 mL, Non-Sterile (100 cups)Cat. No. 4112-840-000-9120 mL, Sterile (100 individually wrapped cups)Cat. No. 4112-165-000-9

H-PETTE® AND H-PETTE®-II

3611 H-Pette without Blade, 1000 pieces3612 H-Pette with Blade, 1000 pieces3613 H-Pette Remover3615 H-Pette II without Blade, 1000 pieces

H-Pette and H-Pette II provide a safe and easy way to dispense

a controlled drop of blood to a glass slide for preparing

differential slides.

New H-Pette II features a metal cannula for ease of insertion

through the stopper of collection tubes.

Using H-Pette is simple. Just insert H-Pette into the stopper of

any size blood collection tube, invert tube and transfer a drop of

blood to a glass slide or test cassette. Original molded H-Pettes

are also available with an integral blade for making differential

slides. H-Pettes remain in place in the stopper and are disposed

of with the tubes. They can also be easily removed if necessary.

H - P E T T E S A R E A V A I L A B L E F R O M H E L E N A L A B O R A T O R I E S A T 1 - 8 0 0 - 2 3 1 - 5 6 6 3

Page 4: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

I N T E G R AT E D S O L U T I O N S | A U TO M AT E D P R O C E S S I N G

Helena TO U C H S E R I E S

Labcon D I S P O S A B L E P L A S T I C S 3 6

C-PETTE® AND C-PETTE-E

U-PETTE®

8 0 0 - 2 2 7 - 1 4 6 6 | W W W. L A B C O N . C O M

The new C-Pette and C-Pette-E make

delivering samples into the test cards and

cassettes used by point of care analyzers easy

and efficient, while reducing risk of biohazard

exposure. Original C-Pette features an easy

to insert metal cannula, while the all-plastic

C-Pette-E is a more economical alternative.

C-Pettes are ideal for use with the Abbott

i-STAT® test cartridges. Original C-Pette, 500 pieces – Cat. No. 7630-500-000-9 C-Pette-E, 500 pieces – Cat. No. 7625-500-000-9

U-Pettes provide an easy way to dispense blood

into a test card or cassette, like our Cascade Abrazo

or Abbott’s iSTAT, without uncapping the tube. The

unique tab design allows blood to be dispensed two

different ways as needed.

For larger samples, place the tip of the U-Pette all the way to the bottom of the sample well. Counterpressure with the tabs while pushing down on the tube to dispense sample as needed.

For small volumes, hold the tip over the sample port to dispense sample into the port by using the tabs to counterpressure like a syringe.

i-STAT is a registered trademark of the Abbott Group of Companies

U-Pette, 100 pieces – Cat. No. 7626-540-000-9U-Pette, 500 pieces – Cat. No. 7626-500-000-9

C - P E T T E A N D U - P E T T E A R E A V A I L A B L E D I R E C T L Y F R O M L A B C O N

Page 5: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

I N T E G R AT E D S O L U T I O N S

Helena

The Touch integrated gel ELP system puts the power of touch technology in your hands

to knock out all your protein, immunofixation, hemoglobin and cholesterol testing quickly

and efficiently. The Touch system is faster and smaller, plus provides integration with the V8

capillary system and ease of interpretation with the Myeloma Module for reporting results.

TO U C H S E R I E S 4

ESH TOUCH SPIFE TOUCH QS TOUCH + 1 2 3

F A S T E R P R O C E S S I N G M Y E L O M A T R A C K I N GTO U C H S C R E E N S

Interactive Webinars are available

to show you how much more efficient

your workflow can be. Schedule today

by emailing [email protected]

Helena O C C U LT B L O O D T E S T S 3 5

COLOCARE

H E L E N A O C C U LT B L O O D T E S T S

COLOSCREENColoScreen offers the sensitivity and specificity of traditional guaiac methods (10 mg/g) at a lower cost.

5076 1000 Singles Lab Pack5072 100 Singles Lab Pack 5077 Developer, 20 x 15 mL 5078 Developer, 50 x 2 mL 5073 80 Triples w/Mailer 5079 Perforated Tape/Developer

COLOSCREEN-ES

5086 100 Singles Lab Pack5085 80 Triples w/Mailer 5088 ES Developer, 20 x 15 mL

ColoScreen-ES is an extra-sensitive (0.3 mg/g feces) guaiac test with vivid color development for easier interpretation.

ColoCARE is the easiest, most economical way to screen for fecal occult bleeding. ColoCARE’s sensitivity is roughly equivalent to traditional guaiac FOBT. Helena also supplies the support materials needed for successful screens. Educational handouts, wall charts, and promotional materials are available free of charge with your ColoCARE order. With ColoCARE, there is no stool handling or laboratory processing.

5651 Office Pack 50 Take-Home Kits, 3 test pads each

5650 Screening Pack 250 Take-Home Kits, 3 test pads each

ColoCARE is clean, simple and effective with higher compliance rates than traditional guaiac slide tests.

Leading medical institutions enjoy great performance, and even greater savings, with ColoScreen and ColoScreen-ES occult blood tests.

Page 6: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

HelenaESH TOUCH FEATURES

E S H TO U C H ® 5

THE NEXT GENERATIONof Electrophoresis Sample Handler joins the Touch Series

of analyzers as part of Helena’s integrated solution for

high volume electrophoresis workloads. ESH Touch

provides automated front-end specimen processing for

the SPIFE Touch with positive patient ID and interface to

QuickScan Touch Plus or LIS - in a small, fast, quiet, flexible

and user-friendly package.

ESH Touch transfers samples directly from primary patient

tubes to barcoded sample trays, ready for application to

agarose gels by the SPIFE Touch. Its 100-sample capacity

accommodates the largest SPIFE Touch gels, plus dilution

schemes for each sample can be specified. A touch screen

interface makes the system easy to use.

Primary tube sampling with liquid level sensor

User-friendly touch screen interface

Improved liquid level detection

Barcode reader with LIS interface for positive ID

100-sample capacity

Flexible dilutions, i.e. per sample analyte

Smaller footprint

50% faster sample tray preparation

Quieter operation

H I G H V O L U M E E L E C T R O P H O R E S I S W O R K L O A D S

Helena C O L O S C R E E N ® i F O B T 3 4

SENSITIVITY - SPECIFICITY - VALUEHelena ColoScreen occult blood products have

been a trusted brand in physician offices and clinical

laboratories since 1981. Next generation ColoScreen

iFOBT for immunochemical detection of human

hemoglobin continues that tradition, offering the

latest technology for screening of gastrointestinal

disease, including colorectal cancer. ColoScreen

iFOBT is a one-step lateral flow chromatographic

immunoassay.

ColoScreen iFOBT exceeds the sensitivity standards

recommended by the American Cancer Society for

annual screening of everyone aged 45+. Early detection

is the answer and ColoScreen iFOBT is the key!

I M M U N O C H E M I C A L F O B T A S S AY

T E S T I N G I S S I M P L E

FEATURES BENEFITSImmunochemical Lateral flow chromatographic assay immunoassay with built-in QC

Highly specific Specific for human hemoglobin – No interference from peroxidase or blood from dietary sources

Sensitivity of Greater sensitivity to hemoglobin 50 µg/g feces than standard guaiac assays

Easy, odor-free Sample maintains integrity collection tube during short-term storage

5061 ColoScreen iFOBT Collection Tubes - 30/pkg5062 ColoScreen iFOBT Test Cassettes - 30/pkg5063 ColoScreen iFOBT Mailers - 30/pkg5064 ColoScreen iFOBT Office Pack - 30 each (Collection Tubes, Cassettes and Mailers)

1 Patient sample is collected and transported in a unique collection tube containing stabilizing buffer with the built-in sampling wand.

2 In the laboratory, sample is dispensed from the collection tube directly into the test cassette.

3 Quality control and patient results are read in the window.

Page 7: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

HelenaSPIFE TOUCH FEATURES

S P I F E TO U C H ® 6

THE NUCLEUS OF THE TOUCH SYSTEMSPIFE Touch is the proven, workhorse solution for

clinical zone electrophoresis needs. It’s versatile and

reliable with multiple gels sizes for flexibility. A full

menu of analytes includes proteins, IFEs,

hemoglobins, direct cholesterol with Lp(a)-c,

isoenzymes, lipoproteins and oligoclonal banding.

A touch screen interface, faster processing and

organized workflow means greater efficiency over

previous generations of SPIFE and other brands

of electrophoresis analyzers.

Easy-to-use touch screen interface

Integrates with ESH Touch and QS Touch for positive tracking of patient samples

New applicator blades provide fast, clean and accurate sampling of up to 100 samples per gel

Peltier temperature control preserves sample integrity and provides crisp separations

Automatic application of reagents for enzymatic assays or stains for visible analytes

A full menu of analytes and gel sizes

A D VA N C E D E L E C T R O P H O R E S I S T E C H N O L O G Y

D I S P O S A B L E P L A S T I C S | O C C U LT B L O O D T E S T I N G

P lastics A N D F O B T

Page 8: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E TO U C H ® 7

• Tight crisp bands• Simple multi-channel antisera

application• Antisera balanced for highest

sensitivity with least blush

Cat. No. 3408 15 profileCat. No. 3409 9 profileCat. No. 3401 6 profileCat. No. 3406 3 profileCat. No. 3351 1/2 profile

SPIFE Anti-Dara Antiserum* – binds up therapeutic monoclonals so it never appears in the SPE or IFE pattern.

• Classic 5-band or split beta separations• Superior resolution and sensitivity• Serum applied neat; no concentration needed for urines• Gel sizes for every workload – up to 100 samples per gel

ClassicCat. No. 3460 60 sampleCat. No. 3461 40 sampleCat. No. 3462 20 sampleCat. No. 3405 10/20 sample

Split-BetaCat. No. 3398 100 sampleCat. No. 3399 80 sampleCat. No. 3420 60 sampleCat. No. 3421 40 sampleCat. No. 3422 20 sampleCat. No. 3350 10/20 sample

Separations with SPIFE Alkaline Hemoglobin mimic classic cellulose acetate and are the front line for detecting hemoglobinopathies. Use of acid blue stain provides excellent sensitivity and linearity. Precise temperature control improves separation, resolving even problematic Hemoglobin H.

3415 20 sample3429 10 sample

SPIFE Acid Hemoglobin is a much less cumbersome method than conventional citrate agar for characterizing hemoglobinopathies. The use of acid blue stain brings linearity not available with O-Tolidine or O-Dianisidine based systems. Finished gels are stable in storage and will not continue to darken.

3418 20 sample3419 10/20 sample

IMMUNOFIX PROFILE

PROTEINS CLASSIC OR SPLIT

ALKALINE HEMOGLOBIN ACID HEMOGLOBIN

*For research use only. June 2019

P R E V I E W

Helena H E M O S TA S I S R E A G E N T S 3 2

H E L E N A H E M O S TA S I S R E A G E N T S

SPECIALTY ASSAYED CONTROLS AND REFERENCE PLASMA

QUALITY ASSURANCE REVIEW (QAR)

ELISA ASSAYS

FACTOR DEFICIENT SUBSTRATES

PT, APTT AND FIBRINOGEN CONTROLS

5190 Factor II Deficient Substrate - Bovine 5191 Factor V Congenital Deficient Substrate 5192 Factor VII Congenital Deficient Substrate5193 Factor VIII Congenital Deficient Substrate 5194 Factor IX Congenital Deficient Substrate 5195 Factor X Congenital Deficient Substrate 5196 Factor XI Congenital Deficient Substrate 5197 Factor XII Congenital Deficient Substrate

Helena offers quality factor deficient substrates with <1% residual factor activity. Each kit includes 10 x 1 mL vials.

• Norm-Trol 1 is a lyophilized normal level control for PT, aPTT and Fibrinogen assays

• Ab-Trol 2 and Ab-Trol 3 provide moderately elevated and very elevated, respectively, PT and aPTT controls

5186 Norm-Trol 1, 10 x 1 mL5187 Ab-Trol 2, 10 x 1 mL5183 Ab-Trol 3, 10 x 1 mL

• S.A.R.P. is a reference plasma prepared from a healthy donor pool and calibrated against either ISTH Secondary Coagulation Standard or WHO International Standard

• Specialty Assayed Controls are available in 2 levels: S.A.C.-1 normal and S.A.C.-2 abnormal

• S.A.R.P. and S.A.C. are assayed for: PT, aPTT, Fibrinogen, Factors II, V, VII, VIII, IX, X, XI, XII, Protein C, free & total Protein S, Ristocetin Cofactor, and vWF:Ag

5301 S.A.C.-1 (Normal), 10 x 1 mL5302 S.A.C.-2 (Abnormal), 10 x 1 mL5185 S.A.R.P., 10 x 1 mL

5290 vWF:Ag ELISA Kit, 96 tests5291 Protein C ELISA Kit, 96 tests 5292 Protein S (Free & Total) ELISA Kit, 96 tests5293 Monoclonal Free Protein S ELISA Kit, 96 tests

We offer QAR, a free computer service for analyzing daily QC data for shifts or trends and establishing mean control values for individual laboratories.

Page 9: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E I g G I E F 8

THE GOLD STANDARDThe 2017 revision of the McDonald criteria for diagnosing

multiple sclerosis places an increased emphasis on CSF

testing. When the diagnosis is unclear, rather than wait

for the disease to present with more overt symptoms or

MRI findings, the new recommendations are to test for

oligoclonal bands.

Developed by leading experts, SPIFE IgG IEF technique is

the “gold standard” method for determining intrathecal IgG

synthesis. This method uses highly sensitive immunoblotting

resulting in a 95% sensitivity level. The concentration of

individual bands may be as low as 2% of the total CSF IgG

but can be seen against the background of polyclonal IgG

present through filtration from the blood, even while the

total CSF IgG concentration is within the reference range.

D I A G N O S I N G M U LT I P L E S C L E R O S I S

3389 5 profiles3385 10 profiles

It is now recommended that the presence of CSF oligoclonal bands be allowed to substitute for the dissemination of time criteria in diagnosing patients with clinical symptoms of multiple sclerosis.

AJ Thompson, BL Banwell, F Barkhof, et. al., The Lancet, December 2017

N E W !

The SPIFE IgG IEF method of nitrocellulose immunoblotting “remains the ‘gold standard’ method recommended by the International Consensus publication and is preferred over IEF followed by immunofixation. The onus is on the protagonists of in-gel immunofixation to show that it performs to the same level as the de-facto standard in both sensitivity as well as the very wide range of IgG concentrations.”

Emeritus Prof E J Thompson, PhD MD DSc FRCPath FRCP November 2017

Dr. Thompson, together with his team developed the IgG IEF/immunoblot method and have used it confirm the diagnosis of multiple sclerosis on a wide international scale.

2017 MCDONALD CRITERIA

Helena C A S C A D E ® M 4 3 1

HEMOSTASIS ANALYZER

PROTHROMBIN TIME

ACTIVATED PARTIAL THROMBOPLASTIN TIME

FIBRINOGEN AND THROMBIN TIME

H E M O S TA S I S A N A LY Z E R

Cascade M4 is a semi-automated hemostasis analyzer that is ideal for all routine clotting assays – PTs, aPTTs, thrombins, fibrinogens, and factor assays.

• State-of-the-art photo optics • On-screen prompts • Easy-to-use keypad• Only a 15”x15” footprint

1711 Cascade M4 Analyzer1718 Cascade M4 Cuvettes1720 Printer Paper / Cascade M4

With its low ISI value of 1.0 to 1.2, Helena’s Thromboplastin-LI is just right for your laboratory.5248 Thromboplastin-LI, 250 tests5249 Thromboplastin-LI, 500 tests

Offering quality and economy, all reagents are convenient, ready-to-use liquids with soluble ellagic acid activator.5388 aPTT-SA & CaCl2, 250 tests5389 aPTT-SA & CaCl2, 500 tests 5387 aPTT-SA, 1000 tests5386 CaCl2, 1000 tests

Helena Fibrinogen and Thrombin Time Assays are well-suited to automated, semi-automated and manual systems.5377 Thrombin Time Reagent, 250 tests5376 Fibrinogen Assay Kit, 100 tests5374 Thrombin Reagent, 200 tests5375 Owren’s Veronal Buffer5379 Fibrinogen Calibrator

Page 10: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E TO U C H ® 9

CHOLESTEROL PROFILE

ALKALINE PHOSPHATASE

HI-RES PROTEINS

CK AND LD ISOENZYMES

LIPOPROTEIN SEPARATION

3438 100 sample3439 80 sample3440 60 sample

3441 40 sample3442 20 sample3443 10 sample

SPIFE Cholesterol measures the cholesterol content of HDL, LDL, VLDL and Lp(a) in a single assay. Lp(a) is the most atherogenic lipoprotein in the human body and is a proven causal factor of heart disease.

• Excellent correlation to ultracentrifugation

• Favorable reimbursement margin

• Lp(a)-c single best predictor of plaque and major ischemic events

• Unaffected by lipid isoform size making it analytically superior to Lp(a)-mass

3430 20 sample 3340 80 sample3341 60 sample3342 40 sample

3343 20 sample3344 10 sample

3346 40 sample3345 20 sample

3335 60 sample3336 40 sample3337 20 sample3338 10/20 sample

3332 40 sample3333 20 sample3334 10/20 sample

Helena A G G R A M R E A G E N T S 3 0

P L AT E L E T A G G R E G AT I O N R E A G E N T S

AGGRAM PLATELET AGGREGATION REAGENTS

RISTOCETIN COFACTOR REAGENTS

Helena’s platelet reagents provide outstanding stability and performance. Reagents are optimized for use with AggRAM, but may be used on any turbidometric aggregometer of similar quality.

5364 Arachidonic Acid, 2 x 1 mL5366 ADP, 2 x 1 mL5367 Epinephrine, 2 x 1 mL5368 Collagen, 2 x 1 mL5369 Platelet Aggregation Kit (5366, 5367, 5368)5199 Ristocetin (for RIPA), 10 x 0.5 mL5365 Tris-Buffered Saline, 1 x 125 mL

Ristocetin Cofactor is more sensitive than RIPA to mild reductions in vWF and is more often used to monitor therapy in vWD patients. Kit includes ristocetin, formalinized platelets, S.A.R.P., abnormal control and tris-buffered saline.

5370 Ristocetin Cofactor Kit, 50 tests5371 Lyophilized Platelets, 5 x 5 mL5373 Ristocetin Cofactor Abn Control, 5 x 0.5 mL5372 Ristocetin (10 mg/mL), 5 x 1.5 mL5365 Tris-Buffered Saline, 1 x 125 mL5356 Lyophilized Platelets, 5 x 10 mL

Page 11: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

QS TOUCH + FEATURES

Auto M-spike delimiting provides greater consistency between users

Barcoded gels allow positive ID from patient tube to final results with LIS interface

Intelligent software enhances automation of fraction quantitation

Patterns can be reviewed and edited remotely

Full audit trail accountability

Auto pair allows user to overlay up to two previous scans on the patient's current results

Sharp patterns with adjustable contrast and brightness enhance small bands

Helena Q U I C K S C A N TO U C H ® P L U S 1 0

FOR IMAGING AND QUANTITATIONThe new QuickScan Touch Plus includes

a more powerful Windows 10 CPU and a

new SQL database format for enhanced

data management. Data from multiple

Helena systems, including gel and CE, can

be electronically paired for interpreting,

reviewing and tracking of results.

D E N S I TO M E T R Y & D ATA M A N A G E M E N T

This new addition unifies each patient’s current and historical electrophoresis and supportive data into a single portal for interpreting, tracking and reviewing results.

N E W !

MYELOMA TRACKING MODULE

Helena A G G R A M ® 2 9

PLATELET AGGREGATIONAggRAM for platelet aggregation testing couples

four-channel laser optic modules with an easy to

use interface and powerful data handling features.

Up to two modules can be run per Remote Analyzer

computer, providing up to eight channels to handle

your tough workload demands. Laser diode technology

provides excellent precision across all channels in

conjunction with an improved algorithm for slope

calculation providing exceptional precision for ristocetin

cofactor testing. Easily generate Levey-Jennings charts,

standard curves, etc. with an integral action log and

evaluate and chart quality control for ristocetin cofactor

based on Westgard rules.

M O D U L A R P L AT E L E T A G G R E G O M E T E R

AGGRAM FEATURES

On-screen prompts step users through testing

Multi-window viewing greatly increases efficiency

Quick access to data input screens

Three password levels, from user to administrator

Barcode and LIS capabilities

Automatically calculates slope and max percent aggregation

Displays/prints lag phase

Can automatically calculate and smooth curves

Reference overlay capability1484 AggRAM Analyzer1486 AggRAM Module

Page 12: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena Q U I C K S C A N TO U C H ® P L U S 1 1

MYELOMA MODULE TRACKING OPTION

REVERSE IMAGE REPORTS AND WORKLISTS

See everything in one place Each patient’s current results are auto-paired with their previous data from a virtually unlimited data store, including competitive system data. Available total protein, albumin, free light chain ratio and nephelometric data can also be incorporated for review. If it’s paired, it’s there.

Scroll through to spot changes Reports are presented as scrollable thumbnails to quickly detect progression or regression of disease. Initial, review and release – Queues with ID audit trail

are provided to collate initial results by the operator, reports awaiting review, and final results ready to report to the clinician.

The new Myeloma Module is an optional tracking feature that allows quick review and reporting of results from both the SPIFE zone and the V8 CE systems.

Invert the background of IFE images on screen to create a “negative” view to enhance visualization and aid in interpretation. View simultaneously with positive image system.

Reports and worklists are completely customizable. Create a single-page report that includes one patient's SPE and IFE with interpretation.

Helena C A S C A D E A B R A Z O ® * 2 8

P O I N T O F C A R E H E M O S TA S I S A N A LY Z E R

SELECT TEST

SCAN BARCODE

ADD SAMPLE

5720 Cascade Abrazo PT-WB Assay5739 Cascade Abrazo PT-WB Level 1 Control5740 Cascade Abrazo PT-WB Level 2 Control

5721 Cascade Abrazo PT-C Assay5741 Cascade Abrazo PT-C Level 1 Control5742 Cascade Abrazo PT-C Level 2 Control

5722 Cascade Abrazo aPTT Assay 5743 Cascade Abrazo aPTT Level 1 Control5744 Cascade Abrazo aPTT Level 2 Control

5724 Cascade Abrazo c-ACT Assay 5737 Cascade Abrazo c-ACT Level 1 Control5738 Cascade Abrazo c-ACT Level 2 Control

5701 Cascade Abrazo c-ACT-LR Assay 5727 Cascade Abrazo c-ACT-LR Level 1 Control5728 Cascade Abrazo c-ACT-LR Level 2 Control

5718 35 µL Micropipette 5800 Dispo Capillary Pipettes 5848 Cascade Abrazo EQC Assay

Cascade Abrazo and assays not currently available in USA. FDA 510(k) not yet released.

5710 Cascade Abrazo Analyzer5712 Cascade Abrazo Docking Station5716 Cascade Abrazo Admin Software

ABRAZO ANALYZER AND ASSAYS

*

Page 13: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena Q U I C K G E L ® 1 2

THE QUICKGEL CHAMBERQuickGel manual electrophoresis products are

ideal for small runs and low volume testing,

separating 10 to 20 samples per run efficiently

and cost effectively. Like all of Helena’s

premium agarose gels, QuickGels have

built-in buffer blocks for ease of use and

separations that are crisp and clear. The

QuickGel Chamber features a cooled

electrophoresis platen and built-in carbon

electrodes. The QuickGel Chamber also

serves as an incubator and dryer by simply

changing out the lid.

M A N U A L E L E C T R O P H O R E S I S

Recommended for use with

the QuickGel Chamber is the

completely solid state TITAN Plus

Power Supply. A synchronous

timer assures precise control with

automatic end-of-run signal

and shut-off.

1284 QuickGel Chamber1274 QuickGel Applicator Kit (Applicator, Base, Weights, Cup Tray)

1504 TITAN Plus Power Supply, 110V1505 TITAN Plus Power Supply, 220V

TITAN PLUS POWER SUPPLY

Helena C A S C A D E A B R A Z O ® * 2 7

POC HEMOSTASIS ANALYZERCascade Abrazo is a portable, point of care hemostasis

analyzer with a touch screen display, built-in barcode

reader, powerful software, and an easy-to-use reagent

platform. Abrazo will currently run PT, aPTT, c-ACT

and low-range c-ACT. Other hemostasis assays, like

fibrinogen, direct thrombin inhibitors, and heparin

and protamine dose response are in development to

make the Abrazo the most comprehensive coagulation

management system available.

P O I N T O F C A R E H E M O S TA S I S A N A LY Z E R

ABRAZO FEATURES

Easy-to-use, card-based dry chemistry tests

Uses a single drop of blood

Touch screen interface

Built-in WiFi and USB

Data storage on instrument

Admin software available for remote instrument configuration

Multiple user security levels

QC with lockout options

Docking station available for instrument charging and communication link

PT-WB - Prothrombin Time using a whole blood sample

aPTT - Activated partial thromboplastin time using a citrated whole blood sample

PT-C - Prothrombin Time using a citrated whole blood sample

c-ACT - A celite activator base for monitoring moderate to high heparin concentrations

c-ACT-LR - A celite activator base for monitoring low to moderate heparin concentrations

Cascade Abrazo and assays not currently available in USA. FDA 510(k) not yet released.*

Page 14: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

N OT E

Helena Q U I C K G E L A S S AY S 1 3

3551 1 or 2 profiles 3551T 1 or 2 profiles

3550 10/20 samples3550T 10/20 samples

3538T 10/20 samples

3529 10 samples3529T 10 samples

3519 10/20 samples 3543T 10/20 samples 3544T 10 samples

3534T 10/20 samples

3505 10/20 samples3505T 10/20 samples

Kits contain gels and supplies for

10 samples per gel. Additional

applicators are available for up to 20

samples per gel on most assays. “T”

indicates template application kits.

L I P O P R OT E I NA C I D H B

C K I S O E N Z Y M E

A L K A L I N E H B

S P E S P L I T B E TA I M M U N O F I X

C H O L E S T E R O L

L D I S O E N Z Y M ES P E C L A S S I C

Helena A C TA LY K E ® X L 2 6

A C T I VAT E D C L OT T I N G T I M E R E A G E N T S

EASY HEPARIN MONITORINGActalyke analyzers and ACT reagent tubes provide

a precise, reliable and sensitive system for heparin

monitoring.

Helena offers a complete line of single-activator tubes,

including celite, kaolin and glass-bead, as well as unique

triple activator MAX-ACT tubes. MAX-ACT ensures

maximal activation of Factor XII for more reliable heparin

dosing decisions, reducing post-operative bleeding.

5770 Actalyke XL Analyzer (dual well)

5763 Actalyke Mini II Analyzer (single well)

MAX-ACT MAX-ACT Reagent Tubes (50/box)

G-ACT Glass Bead ACT Reagent Tubes (50/box)

K-ACT Kaolin ACT Reagent Tubes (50/box)

C-ACT Celite ACT Reagent Tubes (50/box)

ACTALYKE XL FEATURES

Two-point clot detection for precise, reliable and sensitive activated clotting time testing

Single or dual test well analyzers

Biologic and electronic QC functions

Advanced data management features and connectivity on XL

Unique, triple activator MAX-ACT tubes

Optional bar code reader for patient ID entry

Large touch screen display

Page 15: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

A U TO M AT E D E L E C T R O P H O R E S I S

Helena S P I F E 4 0 0 0

Helena P L AT E L E T W O R K S ® 2 5

PRE-SURGICAL SCREENINGPlateletworks effectively determines functional platelet count

and true platelet aggregation or inhibition using traditional

ADP, Collagen or Arachidonic Acid agonists. All that’s needed

is an impedance cell counter and Plateletworks reagent tubes.

Just add whole blood to baseline and agonist tubes, perform

cell counts on each tube, and calculate the final results. It’s that

simple with reportable results in less than 10 minutes.

P L AT E L E T F U N C T I O N S C R E E N I N G

5860 Plateletworks ADP Kit

5862 Plateletworks Collagen Kit

5864 Plateletworks Arachidonic Acid Kit

5850 Plateletworks Combo-15 Kit

5852 Plateletworks Combo-25 Kit

5854 Plateletworks Combo-10 Kit

Determines functional platelet count and % aggregation, % inhibition on fresh whole blood

Results are analogous to "gold standard" aggregometry

Works with any impedance hematology analyzer

Detects effects of anti-platelet drug therapies

Reduces platelet usage during cardiopulmonary bypass surgery

No specialized training or additional equipment needed

PLATELET FUNCTION SCREENING

Page 16: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

HelenaSPIFE 4000 FEATURES

S P I F E ® 4 0 0 0 1 5

TOTAL AUTOMATIONTotal batch-mode, walkaway electrophoresis automation

is here in SPIFE 4000! Just load sample tubes, press go,

and return for your printed IFE and SPE results. A full day’s

mixed run of SPEs and IFEs takes about 30 minutes of

tech time for set up. Alkaline and acid hemoglobin assays

are also available. With SPIFE 4000’s hands-off approach,

a laboratory can reasonably expect to be able to run 24

hours per day 7 days a week.

Fully automated sampling for SPE and IFE

Auto applicator and electrophoresis

Auto immunofixation

Integrated auto staining and drying

Powerful user interface

Positive sample ID

High sensitivity assays

Remote edit and review

A U TO M AT E D E L E C T R O P H O R E S I S

Now available on the SPIFE 4000, the Myeloma Module unifies each patient’s current and historical electrophoresis and supportive data into a single portal for interpreting, tracking and reviewing results (see page 11).

N E W !

MYELOMA TRACKING MODULE

PLATELET SCREENING

HEMOSTASIS REAGENTS

POINT OF CARE TESTING

P L AT E L E T W O R K S | A C TA LY K E X L | M A X - A C T

Helena H E M O S TA S I S

Page 17: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E ® 4 0 0 0 1 6

WA L K AWAY A U TO M AT I O N

• Liquid level sensing

• Auto dilutions for immunofixation

• Positive ID from tube to gel to final report

• Automatic application of samples to gels

• Application system unaffected by triglycerides or large proteins

• Peltier-driven temperature controlled chamber

• Color-coded antisera stored on-board, ready to use

• Antisera applied through a rigid template to eliminate crossover

• Auto press and blot to assure clear background

AUTO SAMPLING FOR SPE AND IFE

AUTO APPLICATOR AND ELECTROPHORESIS

AUTO IMMUNOFIXATION

Helena V 8 N E X U S 2 3

A U TO M AT E D C L I N I C A L C A P I L L A R Y E L E C T R O P H O R E S I S

• User-scheduled instrument maintenance – ready to go when techs arrive

• Fully automated maintenance procedures: Start Up Method Change Shut Down

• Automated purging for capillary conditioning and protection

• Service alert feature• Automated system check

• Advanced status feedback• Real time monitoring of sample and

electrophoresis timing• Intuitive buffer and reagent volume monitoring• Maintenance status and timing monitoring• Service alert

AUTO MAINTENANCE

ON-BOARD DIAGNOSTICS

C O M I N G S O O N !

• Automated high volume sample handling

• Added capacity of 440 samples plus continuous feed

• 552 SPEs in 6 hours

V8 NEXUS MAX

Page 18: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E ® 4 0 0 0 1 7

WA L K AWAY A U TO M AT I O N

AUTO STAINING AND DRYING

INTEGRATED AUTO SCANNING

POWERFUL USER INTERFACE

• On-board staining with no gel transfers

• Auto destain and wash for clear backgrounds

• Automated drying and transfer to scanner

• Automatic setting of scan parameters

• Full editing and interpretation capabilities

• Final results can be printed and/or exported to LIS

• Bi-directional LIS interface

• System provides status of each gel in process

• On-screen system alerts

Helena V 8 N E X U S 2 2

A U TO M AT E D C L I N I C A L C A P I L L A R Y E L E C T R O P H O R E S I S

• Continuous sample loading• Up to 112 samples on board (440 with Max)• Excellent liquid sensing technology• 50 µL sample dead volume (sample tube dependent)• Positive patient identification and full

sample traceability• Ability to reflex to gel tray

• Six on-board buffer locations• Four assay buffers, two rinse/utility buffers• Multiple method capability• All buffers are barcoded for full audit traceability• Automated buffer replenishment• High-throughput screening• "Efficient" walkaway automation• One buffer bottle purged at a time

• Ten on-board reagent locations• Peltier temperature controlled reagent bay• Controlled stability and reduction in reagent loss• Four diluent reagent positions

SAMPLE HANDLING

BUFFER HANDLING

REAGENT HANDLING

Serum Proteins Fast CE Urine Proteins Immunodisplacement

88 88 14tests/hr tests/hr tests/hr

1803 V8 Immunodisplacement Kit (50 tests)1805 V8 Serum Protein SPE Kit (500 tests)

Cat. No. Item

Page 19: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E ® 4 0 0 0 1 8

E X C E L L E N T R E S O L U T I O N A N D S E N S I T I V I T Y

SPIFE 4000 can perform alkaline hemoglobin separation of up to ten samples per gel.

• Mobilities mimic traditional cellulose acetate

• Acid blue stain enhances linearity and visualization

• Automated from sample application to finished gel; one gel per run.

SPIFE 4000 totally automates protein electrophoresis with excellent resolution and sensitivity.

2310 - 280 tests

2320 - 80 tests

2300 - 40 tests

2322 - 140 tests

• Applicators unaffected by triglycerides or large proteins

• Active cooling for excellent split-beta separation with no degradation

• Test 28 samples per gel and up to 756 samples in 8 hours

All the steps for immunofixation, including antisera application are automated by SPIFE 4000.

• SPIFE 4000 performs all the needed dilutions and applies samples to gels

• Antisera are automatically applied to gels with balanced affinity and avidity for best sensitivity with the least amount of blush

Separate up to 14 acid hemoglobin samples per gel and up to three gels per run on SPIFE 4000.

• Aids in identifying hemoglobinopathies

• Stable in storage with acid blue stain

• Excellent separations

PROTEINS

ALKALINE HB

IMMUNOFIXATION

ACID HB

HelenaV8 NEXUS HIGHLIGHTED FEATURES

V 8 N E X U S 2 1

A U TO M AT E D C L I N I C A L C A P I L L A R Y E L E C T R O P H O R E S I S

• Drive/control V8 functionality• Advanced editing tools• Statistical calculations• Bi-directional communication with host network• Multiple search parameters with overlay capacity• Full audit trail accountability• QC and validation using Levey-Jennings

PLATINUM 5 AND QUICKSCAN SOFTWARE

Platinum 5 system software provides a

comprehensive set of analytical tools

and user-defined options for ease of

operations. The V8 can also use QuickScan

Touch software for editing, reviewing and

reporting. Previous patient data from the

QuickScan, such as serum and urine IFE

and protein results, can be included on

the capillary electrophoresis reports.

• Useful touch screen operation• Automates identification of normal samples• Easily overlay traces and monitor changes

• User-defined Levey-Jennings and Westgard rules• Live feedback of QC status• Easy identification of QC failures• Analyze individual band plots

INTUITIVE SOFTWARE

PLATINUM 5 IMPROVED QC SUITE

Page 20: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

AUTO CAPILLARY

MYELOMA TRACKING

FASTER RESULTS

A U TO M AT E D C L I N I C A L C A P I L L A R Y E L E C T R O P H O R E S I S

Helena V 8 N E X U S

HelenaV8 NEXUS FEATURES

V 8 N E X U S 2 0

FULLY AUTOMATED CEProteins, Immunodisplacement, Hb

The V8 Nexus features eight capillaries and six on-board

reagent positions that enable full multi-assay functionality

and high throughput. A superior sample handling system

allows continuous loading of samples with auto-dilutions

and auto-preparation of SPIFE sample trays for additional

testing by gel electrophoresis.

High throughput capacity with little user intervention

User-defined, fully automated capillary conditioning and maintenance

Greatly reduced waste

Intuitive software interface with real time monitoring

Full audit trail accountability

Integration of CE and zone data with the advanced reporting and tracking of the Myeloma Module (see page 11)

A U TO M AT E D C L I N I C A L C A P I L L A R Y E L E C T R O P H O R E S I S

V8 UltraScreen Hemoglobin will allow hands-off identification and quantitation of hemoglobin variants. Up to 16 hemoglobin samples can be separated per hour.

I N D E V E L O P M E N T

ULTRASCREEN HEMOGLOBIN

Page 21: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

AUTO CAPILLARY

MYELOMA TRACKING

FASTER RESULTS

A U TO M AT E D C L I N I C A L C A P I L L A R Y E L E C T R O P H O R E S I S

Helena V 8 N E X U S

HelenaV8 NEXUS FEATURES

V 8 N E X U S 2 0

FULLY AUTOMATED CEProteins, Immunodisplacement, Hb

The V8 Nexus features eight capillaries and six on-board

reagent positions that enable full multi-assay functionality

and high throughput. A superior sample handling system

allows continuous loading of samples with auto-dilutions

and auto-preparation of SPIFE sample trays for additional

testing by gel electrophoresis.

High throughput capacity with little user intervention

User-defined, fully automated capillary conditioning and maintenance

Greatly reduced waste

Intuitive software interface with real time monitoring

Full audit trail accountability

Integration of CE and zone data with the advanced reporting and tracking of the Myeloma Module (see page 11)

A U TO M AT E D C L I N I C A L C A P I L L A R Y E L E C T R O P H O R E S I S

V8 UltraScreen Hemoglobin will allow hands-off identification and quantitation of hemoglobin variants. Up to 16 hemoglobin samples can be separated per hour.

I N D E V E L O P M E N T

ULTRASCREEN HEMOGLOBIN

Page 22: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E ® 4 0 0 0 1 8

E XC E L L E N T R E S O L U T I O N A N D S E N S I T I V I T Y

SPIFE 4000 can perform alkaline hemoglobin separation of up to ten samples per gel.

• Mobilities mimic traditional cellulose acetate

• Acid blue stain enhances linearity and visualization

• Automated from sample application to finished gel; one gel per run.

SPIFE 4000 totally automates protein electrophoresis with excellent resolution and sensitivity.

2310 - 280 tests

2320 - 80 tests

2300 - 40 tests

2322 - 140 tests

• Applicators unaffected by triglycerides or large proteins

• Active cooling for excellent split-beta separation with no degradation

• Test 28 samples per gel and up to 756 samples in 8 hours

All the steps for immunofixation, including antisera application are automated by SPIFE 4000.

• SPIFE 4000 performs all the needed dilutions and applies samples to gels

• Antisera are automatically applied to gels with balanced affinity and avidity for best sensitivity with the least amount of blush

Separate up to 14 acid hemoglobin samples per gel and up to three gels per run on SPIFE 4000.

• Aids in identifying hemoglobinopathies

• Stable in storage with acid blue stain

• Excellent separations

PROTEINS

ALKALINE HB

IMMUNOFIXATION

ACID HB

HelenaV8 NEXUS HIGHLIGHTED FEATURES

V 8 N E X U S 2 1

A U TO M AT E D C L I N I C A L C A P I L L A R Y E L E C T R O P H O R E S I S

• Drive/control V8 functionality• Advanced editing tools• Statistical calculations• Bi-directional communication with host network• Multiple search parameters with overlay capacity• Full audit trail accountability• QC and validation using Levey-Jennings

PLATINUM 5 AND QUICKSCAN SOFTWARE

Platinum 5 system software provides a

comprehensive set of analytical tools

and user-defined options for ease of

operations. The V8 can also use QuickScan

Touch software for editing, reviewing and

reporting. Previous patient data from the

QuickScan, such as serum and urine IFE

and protein results, can be included on

the capillary electrophoresis reports.

• Useful touch screen operation• Automates identification of normal samples• Easily overlay traces and monitor changes

• User-defined Levey-Jennings and Westgard rules• Live feedback of QC status• Easy identification of QC failures• Analyze individual band plots

INTUITIVE SOFTWARE

PLATINUM 5 IMPROVED QC SUITE

Page 23: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E ® 4 0 0 0 1 7

WA L K AWAY A U TO M AT I O N

AUTO STAINING AND DRYING

INTEGRATED AUTO SCANNING

POWERFUL USER INTERFACE

• On-board staining with no gel transfers

• Auto destain and wash for clear backgrounds

• Automated drying and transfer to scanner

• Automatic setting of scan parameters

• Full editing and interpretation capabilities

• Final results can be printed and/or exported to LIS

• Bi-directional LIS interface

• System provides status of each gel in process

• On-screen system alerts

Helena V 8 N E X U S 2 2

A U TO M AT E D C L I N I C A L C A P I L L A R Y E L E C T R O P H O R E S I S

• Continuous sample loading• Up to 112 samples on board (440 with Max)• Excellent liquid sensing technology• 50 µL sample dead volume (sample tube dependent)• Positive patient identification and full

sample traceability• Ability to reflex to gel tray

• Six on-board buffer locations• Four assay buffers, two rinse/utility buffers• Multiple method capability• All buffers are barcoded for full audit traceability• Automated buffer replenishment• High-throughput screening• "Efficient" walkaway automation• One buffer bottle purged at a time

• Ten on-board reagent locations• Peltier temperature controlled reagent bay• Controlled stability and reduction in reagent loss• Four diluent reagent positions

SAMPLE HANDLING

BUFFER HANDLING

REAGENT HANDLING

Serum Proteins Fast CE Urine Proteins Immunodisplacement

88 88 14tests/hr tests/hr tests/hr

1803 V8 Immunodisplacement Kit (50 tests)1805 V8 Serum Protein SPE Kit (500 tests)

Cat. No. Item

Page 24: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E ® 4 0 0 0 1 6

WA L K AWAY A U TO M AT I O N

• Liquid level sensing

• Auto dilutions for immunofixation

• Positive ID from tube to gel to final report

• Automatic application of samples to gels

• Application system unaffected by triglycerides or large proteins

• Peltier-driven temperature controlled chamber

• Color-coded antisera stored on-board, ready to use

• Antisera applied through a rigid template to eliminate crossover

• Auto press and blot to assure clear background

AUTO SAMPLING FOR SPE AND IFE

AUTO APPLICATOR AND ELECTROPHORESIS

AUTO IMMUNOFIXATION

Helena V 8 N E X U S 2 3

A U TO M AT E D C L I N I C A L C A P I L L A R Y E L E C T R O P H O R E S I S

• User-scheduled instrument maintenance – ready to go when techs arrive

• Fully automated maintenance procedures: Start Up Method Change Shut Down

• Automated purging for capillary conditioning and protection

• Service alert feature• Automated system check

• Advanced status feedback• Real time monitoring of sample and

electrophoresis timing• Intuitive buffer and reagent volume monitoring• Maintenance status and timing monitoring• Service alert

AUTO MAINTENANCE

ON-BOARD DIAGNOSTICS

C O M I N G S O O N !

• Automated high volume sample handling

• Added capacity of 440 samples plus continuous feed

• 552 SPEs in 6 hours

V8 NEXUS MAX

Page 25: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

HelenaSPIFE 4000 FEATURES

S P I F E ® 4 0 0 0 1 5

TOTAL AUTOMATIONTotal batch-mode, walkaway electrophoresis automation

is here in SPIFE 4000! Just load sample tubes, press go,

and return for your printed IFE and SPE results. A full day’s

mixed run of SPEs and IFEs takes about 30 minutes of

tech time for set up. Alkaline and acid hemoglobin assays

are also available. With SPIFE 4000’s hands-off approach,

a laboratory can reasonably expect to be able to run 24

hours per day 7 days a week.

Fully automated sampling for SPE and IFE

Auto applicator and electrophoresis

Auto immunofixation

Integrated auto staining and drying

Powerful user interface

Positive sample ID

High sensitivity assays

Remote edit and review

A U TO M AT E D E L E C T R O P H O R E S I S

Now available on the SPIFE 4000, the Myeloma Module unifies each patient’s current and historical electrophoresis and supportive data into a single portal for interpreting, tracking and reviewing results (see page 11).

N E W !

MYELOMA TRACKING MODULE

PLATELET SCREENING

HEMOSTASIS REAGENTS

POINT OF CARE TESTING

P L AT E L E T W O R K S | A C TA LY K E X L | M A X - A C T

Helena H E M O S TA S I S

Page 26: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

A U TO M AT E D E L E C T R O P H O R E S I S

Helena S P I F E 4 0 0 0

Helena P L AT E L E T W O R K S ® 2 5

PRE-SURGICAL SCREENINGPlateletworks effectively determines functional platelet count

and true platelet aggregation or inhibition using traditional

ADP, Collagen or Arachidonic Acid agonists. All that’s needed

is an impedance cell counter and Plateletworks reagent tubes.

Just add whole blood to baseline and agonist tubes, perform

cell counts on each tube, and calculate the final results. It’s that

simple with reportable results in less than 10 minutes.

P L AT E L E T F U N C T I O N S C R E E N I N G

5860 Plateletworks ADP Kit

5862 Plateletworks Collagen Kit

5864 Plateletworks Arachidonic Acid Kit

5850 Plateletworks Combo-15 Kit

5852 Plateletworks Combo-25 Kit

5854 Plateletworks Combo-10 Kit

Determines functional platelet count and % aggregation, % inhibition on fresh whole blood

Results are analogous to "gold standard" aggregometry

Works with any impedance hematology analyzer

Detects effects of anti-platelet drug therapies

Reduces platelet usage during cardiopulmonary bypass surgery

No specialized training or additional equipment needed

PLATELET FUNCTION SCREENING

Page 27: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

N OT E

Helena Q U I C K G E L A S S AY S 1 3

3551 1 or 2 profiles 3551T 1 or 2 profiles

3550 10/20 samples3550T 10/20 samples

3538T 10/20 samples

3529 10 samples3529T 10 samples

3519 10/20 samples 3543T 10/20 samples 3544T 10 samples

3534T 10/20 samples

3505 10/20 samples3505T 10/20 samples

Kits contain gels and supplies for

10 samples per gel. Additional

applicators are available for up to 20

samples per gel on most assays. “T”

indicates template application kits.

L I P O P R OT E I NA C I D H B

C K I S O E N Z Y M E

A L K A L I N E H B

S P E S P L I T B E TA I M M U N O F I X

C H O L E S T E R O L

L D I S O E N Z Y M ES P E C L A S S I C

Helena A C TA LY K E ® X L 2 6

A C T I VAT E D C L OT T I N G T I M E R E A G E N T S

EASY HEPARIN MONITORINGActalyke analyzers and ACT reagent tubes provide

a precise, reliable and sensitive system for heparin

monitoring.

Helena offers a complete line of single-activator tubes,

including celite, kaolin and glass-bead, as well as unique

triple activator MAX-ACT tubes. MAX-ACT ensures

maximal activation of Factor XII for more reliable heparin

dosing decisions, reducing post-operative bleeding.

5770 Actalyke XL Analyzer (dual well)

5763 Actalyke Mini II Analyzer (single well)

MAX-ACT MAX-ACT Reagent Tubes (50/box)

G-ACT Glass Bead ACT Reagent Tubes (50/box)

K-ACT Kaolin ACT Reagent Tubes (50/box)

C-ACT Celite ACT Reagent Tubes (50/box)

ACTALYKE XL FEATURES

Two-point clot detection for precise, reliable and sensitive activated clotting time testing

Single or dual test well analyzers

Biologic and electronic QC functions

Advanced data management features and connectivity on XL

Unique, triple activator MAX-ACT tubes

Optional bar code reader for patient ID entry

Large touch screen display

Page 28: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena Q U I C K G E L ® 1 2

THE QUICKGEL CHAMBERQuickGel manual electrophoresis products are

ideal for small runs and low volume testing,

separating 10 to 20 samples per run efficiently

and cost effectively. Like all of Helena’s

premium agarose gels, QuickGels have

built-in buffer blocks for ease of use and

separations that are crisp and clear. The

QuickGel Chamber features a cooled

electrophoresis platen and built-in carbon

electrodes. The QuickGel Chamber also

serves as an incubator and dryer by simply

changing out the lid.

M A N U A L E L E C T R O P H O R E S I S

Recommended for use with

the QuickGel Chamber is the

completely solid state TITAN Plus

Power Supply. A synchronous

timer assures precise control with

automatic end-of-run signal

and shut-off.

1284 QuickGel Chamber1274 QuickGel Applicator Kit (Applicator, Base, Weights, Cup Tray)

1504 TITAN Plus Power Supply, 110V1505 TITAN Plus Power Supply, 220V

TITAN PLUS POWER SUPPLY

Helena C A S C A D E A B R A Z O ® * 2 7

POC HEMOSTASIS ANALYZERCascade Abrazo is a portable, point of care hemostasis

analyzer with a touch screen display, built-in barcode

reader, powerful software, and an easy-to-use reagent

platform. Abrazo will currently run PT, aPTT, c-ACT

and low-range c-ACT. Other hemostasis assays, like

fibrinogen, direct thrombin inhibitors, and heparin

and protamine dose response are in development to

make the Abrazo the most comprehensive coagulation

management system available.

P O I N T O F C A R E H E M O S TA S I S A N A LY Z E R

ABRAZO FEATURES

Easy-to-use, card-based dry chemistry tests

Uses a single drop of blood

Touch screen interface

Built-in WiFi and USB

Data storage on instrument

Admin software available for remote instrument configuration

Multiple user security levels

QC with lockout options

Docking station available for instrument charging and communication link

PT-WB - Prothrombin Time using a whole blood sample

aPTT - Activated partial thromboplastin time using a citrated whole blood sample

PT-C - Prothrombin Time using a citrated whole blood sample

c-ACT - A celite activator base for monitoring moderate to high heparin concentrations

c-ACT-LR - A celite activator base for monitoring low to moderate heparin concentrations

Cascade Abrazo and assays not currently available in USA. FDA 510(k) not yet released.*

Page 29: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena Q U I C K S C A N TO U C H ® P L U S 1 1

MYELOMA MODULE TRACKING OPTION

REVERSE IMAGE REPORTS AND WORKLISTS

See everything in one place Each patient’s current results are auto-paired with their previous data from a virtually unlimited data store, including competitive system data. Available total protein, albumin, free light chain ratio and nephelometric data can also be incorporated for review. If it’s paired, it’s there.

Scroll through to spot changes Reports are presented as scrollable thumbnails to quickly detect progression or regression of disease. Initial, review and release – Queues with ID audit trail

are provided to collate initial results by the operator, reports awaiting review, and final results ready to report to the clinician.

The new Myeloma Module is an optional tracking feature that allows quick review and reporting of results from both the SPIFE zone and the V8 CE systems.

Invert the background of IFE images on screen to create a “negative” view to enhance visualization and aid in interpretation. View simultaneously with positive image system.

Reports and worklists are completely customizable. Create a single-page report that includes one patient's SPE and IFE with interpretation.

Helena C A S C A D E A B R A Z O ® * 2 8

P O I N T O F C A R E H E M O S TA S I S A N A LY Z E R

SELECT TEST

SCAN BARCODE

ADD SAMPLE

5720 Cascade Abrazo PT-WB Assay5739 Cascade Abrazo PT-WB Level 1 Control5740 Cascade Abrazo PT-WB Level 2 Control

5721 Cascade Abrazo PT-C Assay5741 Cascade Abrazo PT-C Level 1 Control5742 Cascade Abrazo PT-C Level 2 Control

5722 Cascade Abrazo aPTT Assay 5743 Cascade Abrazo aPTT Level 1 Control5744 Cascade Abrazo aPTT Level 2 Control

5724 Cascade Abrazo c-ACT Assay 5737 Cascade Abrazo c-ACT Level 1 Control5738 Cascade Abrazo c-ACT Level 2 Control

5701 Cascade Abrazo c-ACT-LR Assay 5727 Cascade Abrazo c-ACT-LR Level 1 Control5728 Cascade Abrazo c-ACT-LR Level 2 Control

5718 35 µL Micropipette 5800 Dispo Capillary Pipettes 5848 Cascade Abrazo EQC Assay

Cascade Abrazo and assays not currently available in USA. FDA 510(k) not yet released.

5710 Cascade Abrazo Analyzer5712 Cascade Abrazo Docking Station5716 Cascade Abrazo Admin Software

ABRAZO ANALYZER AND ASSAYS

*

Page 30: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

QS TOUCH + FEATURES

Auto M-spike delimiting provides greater consistency between users

Barcoded gels allow positive ID from patient tube to final results with LIS interface

Intelligent software enhances automation of fraction quantitation

Patterns can be reviewed and edited remotely

Full audit trail accountability

Auto pair allows user to overlay up to two previous scans on the patient's current results

Sharp patterns with adjustable contrast and brightness enhance small bands

Helena Q U I C K S C A N TO U C H ® P L U S 1 0

FOR IMAGING AND QUANTITATIONThe new QuickScan Touch Plus includes

a more powerful Windows 10 CPU and a

new SQL database format for enhanced

data management. Data from multiple

Helena systems, including gel and CE, can

be electronically paired for interpreting,

reviewing and tracking of results.

D E N S I TO M E T R Y & D ATA M A N A G E M E N T

This new addition unifies each patient’s current and historical electrophoresis and supportive data into a single portal for interpreting, tracking and reviewing results.

N E W !

MYELOMA TRACKING MODULE

Helena A G G R A M ® 2 9

PLATELET AGGREGATIONAggRAM for platelet aggregation testing couples

four-channel laser optic modules with an easy to

use interface and powerful data handling features.

Up to two modules can be run per Remote Analyzer

computer, providing up to eight channels to handle

your tough workload demands. Laser diode technology

provides excellent precision across all channels in

conjunction with an improved algorithm for slope

calculation providing exceptional precision for ristocetin

cofactor testing. Easily generate Levey-Jennings charts,

standard curves, etc. with an integral action log and

evaluate and chart quality control for ristocetin cofactor

based on Westgard rules.

M O D U L A R P L AT E L E T A G G R E G O M E T E R

AGGRAM FEATURES

On-screen prompts step users through testing

Multi-window viewing greatly increases efficiency

Quick access to data input screens

Three password levels, from user to administrator

Barcode and LIS capabilities

Automatically calculates slope and max percent aggregation

Displays/prints lag phase

Can automatically calculate and smooth curves

Reference overlay capability1484 AggRAM Analyzer1486 AggRAM Module

Page 31: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E TO U C H ® 9

CHOLESTEROL PROFILE

ALKALINE PHOSPHATASE

HI-RES PROTEINS

CK AND LD ISOENZYMES

LIPOPROTEIN SEPARATION

3438 100 sample3439 80 sample3440 60 sample

3441 40 sample3442 20 sample3443 10 sample

SPIFE Cholesterol measures the cholesterol content of HDL, LDL, VLDL and Lp(a) in a single assay. Lp(a) is the most atherogenic lipoprotein in the human body and is a proven causal factor of heart disease.

• Excellent correlation to ultracentrifugation

• Favorable reimbursement margin

• Lp(a)-c single best predictor of plaque and major ischemic events

• Unaffected by lipid isoform size making it analytically superior to Lp(a)-mass

3430 20 sample 3340 80 sample3341 60 sample3342 40 sample

3343 20 sample3344 10 sample

3346 40 sample3345 20 sample

3335 60 sample3336 40 sample3337 20 sample3338 10/20 sample

3332 40 sample3333 20 sample3334 10/20 sample

Helena A G G R A M R E A G E N T S 3 0

P L AT E L E T A G G R E G AT I O N R E A G E N T S

AGGRAM PLATELET AGGREGATION REAGENTS

RISTOCETIN COFACTOR REAGENTS

Helena’s platelet reagents provide outstanding stability and performance. Reagents are optimized for use with AggRAM, but may be used on any turbidometric aggregometer of similar quality.

5364 Arachidonic Acid, 2 x 1 mL5366 ADP, 2 x 1 mL5367 Epinephrine, 2 x 1 mL5368 Collagen, 2 x 1 mL5369 Platelet Aggregation Kit (5366, 5367, 5368)5199 Ristocetin (for RIPA), 10 x 0.5 mL5365 Tris-Buffered Saline, 1 x 125 mL

Ristocetin Cofactor is more sensitive than RIPA to mild reductions in vWF and is more often used to monitor therapy in vWD patients. Kit includes ristocetin, formalinized platelets, S.A.R.P., abnormal control and tris-buffered saline.

5370 Ristocetin Cofactor Kit, 50 tests5371 Lyophilized Platelets, 5 x 5 mL5373 Ristocetin Cofactor Abn Control, 5 x 0.5 mL5372 Ristocetin (10 mg/mL), 5 x 1.5 mL5365 Tris-Buffered Saline, 1 x 125 mL5356 Lyophilized Platelets, 5 x 10 mL

Page 32: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E I g G I E F 8

THE GOLD STANDARDThe 2017 revision of the McDonald criteria for diagnosing

multiple sclerosis places an increased emphasis on CSF

testing. When the diagnosis is unclear, rather than wait

for the disease to present with more overt symptoms or

MRI findings, the new recommendations are to test for

oligoclonal bands.

Developed by leading experts, SPIFE IgG IEF technique is

the “gold standard” method for determining intrathecal IgG

synthesis. This method uses highly sensitive immunoblotting

resulting in a 95% sensitivity level. The concentration of

individual bands may be as low as 2% of the total CSF IgG

but can be seen against the background of polyclonal IgG

present through filtration from the blood, even while the

total CSF IgG concentration is within the reference range.

D I A G N O S I N G M U LT I P L E S C L E R O S I S

3389 5 profiles3385 10 profiles

It is now recommended that the presence of CSF oligoclonal bands be allowed to substitute for the dissemination of time criteria in diagnosing patients with clinical symptoms of multiple sclerosis.

AJ Thompson, BL Banwell, F Barkhof, et. al., The Lancet, December 2017

N E W !

The SPIFE IgG IEF method of nitrocellulose immunoblotting “remains the ‘gold standard’ method recommended by the International Consensus publication and is preferred over IEF followed by immunofixation. The onus is on the protagonists of in-gel immunofixation to show that it performs to the same level as the de-facto standard in both sensitivity as well as the very wide range of IgG concentrations.”

Emeritus Prof E J Thompson, PhD MD DSc FRCPath FRCP November 2017

Dr. Thompson, together with his team developed the IgG IEF/immunoblot method and have used it confirm the diagnosis of multiple sclerosis on a wide international scale.

2017 MCDONALD CRITERIA

Helena C A S C A D E ® M 4 3 1

HEMOSTASIS ANALYZER

PROTHROMBIN TIME

ACTIVATED PARTIAL THROMBOPLASTIN TIME

FIBRINOGEN AND THROMBIN TIME

H E M O S TA S I S A N A LY Z E R

Cascade M4 is a semi-automated hemostasis analyzer that is ideal for all routine clotting assays – PTs, aPTTs, thrombins, fibrinogens, and factor assays.

• State-of-the-art photo optics • On-screen prompts • Easy-to-use keypad• Only a 15”x15” footprint

1711 Cascade M4 Analyzer1718 Cascade M4 Cuvettes1720 Printer Paper / Cascade M4

With its low ISI value of 1.0 to 1.2, Helena’s Thromboplastin-LI is just right for your laboratory.5248 Thromboplastin-LI, 250 tests5249 Thromboplastin-LI, 500 tests

Offering quality and economy, all reagents are convenient, ready-to-use liquids with soluble ellagic acid activator.5388 aPTT-SA & CaCl2, 250 tests5389 aPTT-SA & CaCl2, 500 tests 5387 aPTT-SA, 1000 tests5386 CaCl2, 1000 tests

Helena Fibrinogen and Thrombin Time Assays are well-suited to automated, semi-automated and manual systems.5377 Thrombin Time Reagent, 250 tests5376 Fibrinogen Assay Kit, 100 tests5374 Thrombin Reagent, 200 tests5375 Owren’s Veronal Buffer5379 Fibrinogen Calibrator

Page 33: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

Helena S P I F E TO U C H ® 7

• Tight crisp bands• Simple multi-channel antisera

application• Antisera balanced for highest

sensitivity with least blush

Cat. No. 3408 15 profileCat. No. 3409 9 profileCat. No. 3401 6 profileCat. No. 3406 3 profileCat. No. 3351 1/2 profile

SPIFE Anti-Dara Antiserum* – binds up therapeutic monoclonals so it never appears in the SPE or IFE pattern.

• Classic 5-band or split beta separations• Superior resolution and sensitivity• Serum applied neat; no concentration needed for urines• Gel sizes for every workload – up to 100 samples per gel

ClassicCat. No. 3460 60 sampleCat. No. 3461 40 sampleCat. No. 3462 20 sampleCat. No. 3405 10/20 sample

Split-BetaCat. No. 3398 100 sampleCat. No. 3399 80 sampleCat. No. 3420 60 sampleCat. No. 3421 40 sampleCat. No. 3422 20 sampleCat. No. 3350 10/20 sample

Separations with SPIFE Alkaline Hemoglobin mimic classic cellulose acetate and are the front line for detecting hemoglobinopathies. Use of acid blue stain provides excellent sensitivity and linearity. Precise temperature control improves separation, resolving even problematic Hemoglobin H.

3415 20 sample3429 10 sample

SPIFE Acid Hemoglobin is a much less cumbersome method than conventional citrate agar for characterizing hemoglobinopathies. The use of acid blue stain brings linearity not available with O-Tolidine or O-Dianisidine based systems. Finished gels are stable in storage and will not continue to darken.

3418 20 sample3419 10/20 sample

IMMUNOFIX PROFILE

PROTEINS CLASSIC OR SPLIT

ALKALINE HEMOGLOBIN ACID HEMOGLOBIN

*For research use only. June 2019

P R E V I E W

Helena H E M O S TA S I S R E A G E N T S 3 2

H E L E N A H E M O S TA S I S R E A G E N T S

SPECIALTY ASSAYED CONTROLS AND REFERENCE PLASMA

QUALITY ASSURANCE REVIEW (QAR)

ELISA ASSAYS

FACTOR DEFICIENT SUBSTRATES

PT, APTT AND FIBRINOGEN CONTROLS

5190 Factor II Deficient Substrate - Bovine 5191 Factor V Congenital Deficient Substrate 5192 Factor VII Congenital Deficient Substrate5193 Factor VIII Congenital Deficient Substrate 5194 Factor IX Congenital Deficient Substrate 5195 Factor X Congenital Deficient Substrate 5196 Factor XI Congenital Deficient Substrate 5197 Factor XII Congenital Deficient Substrate

Helena offers quality factor deficient substrates with <1% residual factor activity. Each kit includes 10 x 1 mL vials.

• Norm-Trol 1 is a lyophilized normal level control for PT, aPTT and Fibrinogen assays

• Ab-Trol 2 and Ab-Trol 3 provide moderately elevated and very elevated, respectively, PT and aPTT controls

5186 Norm-Trol 1, 10 x 1 mL5187 Ab-Trol 2, 10 x 1 mL5183 Ab-Trol 3, 10 x 1 mL

• S.A.R.P. is a reference plasma prepared from a healthy donor pool and calibrated against either ISTH Secondary Coagulation Standard or WHO International Standard

• Specialty Assayed Controls are available in 2 levels: S.A.C.-1 normal and S.A.C.-2 abnormal

• S.A.R.P. and S.A.C. are assayed for: PT, aPTT, Fibrinogen, Factors II, V, VII, VIII, IX, X, XI, XII, Protein C, free & total Protein S, Ristocetin Cofactor, and vWF:Ag

5301 S.A.C.-1 (Normal), 10 x 1 mL5302 S.A.C.-2 (Abnormal), 10 x 1 mL5185 S.A.R.P., 10 x 1 mL

5290 vWF:Ag ELISA Kit, 96 tests5291 Protein C ELISA Kit, 96 tests 5292 Protein S (Free & Total) ELISA Kit, 96 tests5293 Monoclonal Free Protein S ELISA Kit, 96 tests

We offer QAR, a free computer service for analyzing daily QC data for shifts or trends and establishing mean control values for individual laboratories.

Page 34: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

HelenaSPIFE TOUCH FEATURES

S P I F E TO U C H ® 6

THE NUCLEUS OF THE TOUCH SYSTEMSPIFE Touch is the proven, workhorse solution for

clinical zone electrophoresis needs. It’s versatile and

reliable with multiple gels sizes for flexibility. A full

menu of analytes includes proteins, IFEs,

hemoglobins, direct cholesterol with Lp(a)-c,

isoenzymes, lipoproteins and oligoclonal banding.

A touch screen interface, faster processing and

organized workflow means greater efficiency over

previous generations of SPIFE and other brands

of electrophoresis analyzers.

Easy-to-use touch screen interface

Integrates with ESH Touch and QS Touch for positive tracking of patient samples

New applicator blades provide fast, clean and accurate sampling of up to 100 samples per gel

Peltier temperature control preserves sample integrity and provides crisp separations

Automatic application of reagents for enzymatic assays or stains for visible analytes

A full menu of analytes and gel sizes

A D VA N C E D E L E C T R O P H O R E S I S T E C H N O L O G Y

D I S P O S A B L E P L A S T I C S | O C C U LT B L O O D T E S T I N G

P lastics A N D F O B T

Page 35: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

HelenaESH TOUCH FEATURES

E S H TO U C H ® 5

THE NEXT GENERATIONof Electrophoresis Sample Handler joins the Touch Series

of analyzers as part of Helena’s integrated solution for

high volume electrophoresis workloads. ESH Touch

provides automated front-end specimen processing for

the SPIFE Touch with positive patient ID and interface to

QuickScan Touch Plus or LIS - in a small, fast, quiet, flexible

and user-friendly package.

ESH Touch transfers samples directly from primary patient

tubes to barcoded sample trays, ready for application to

agarose gels by the SPIFE Touch. Its 100-sample capacity

accommodates the largest SPIFE Touch gels, plus dilution

schemes for each sample can be specified. A touch screen

interface makes the system easy to use.

Primary tube sampling with liquid level sensor

User-friendly touch screen interface

Improved liquid level detection

Barcode reader with LIS interface for positive ID

100-sample capacity

Flexible dilutions, i.e. per sample analyte

Smaller footprint

50% faster sample tray preparation

Quieter operation

H I G H V O L U M E E L E C T R O P H O R E S I S W O R K L O A D S

Helena C O L O S C R E E N ® i F O B T 3 4

SENSITIVITY - SPECIFICITY - VALUEHelena ColoScreen occult blood products have

been a trusted brand in physician offices and clinical

laboratories since 1981. Next generation ColoScreen

iFOBT for immunochemical detection of human

hemoglobin continues that tradition, offering the

latest technology for screening of gastrointestinal

disease, including colorectal cancer. ColoScreen

iFOBT is a one-step lateral flow chromatographic

immunoassay.

ColoScreen iFOBT exceeds the sensitivity standards

recommended by the American Cancer Society for

annual screening of everyone aged 45+. Early detection

is the answer and ColoScreen iFOBT is the key!

I M M U N O C H E M I C A L F O B T A S S AY

T E S T I N G I S S I M P L E

FEATURES BENEFITSImmunochemical Lateral flow chromatographic assay immunoassay with built-in QC

Highly specific Specific for human hemoglobin – No interference from peroxidase or blood from dietary sources

Sensitivity of Greater sensitivity to hemoglobin 50 µg/g feces than standard guaiac assays

Easy, odor-free Sample maintains integrity collection tube during short-term storage

5061 ColoScreen iFOBT Collection Tubes - 30/pkg5062 ColoScreen iFOBT Test Cassettes - 30/pkg5063 ColoScreen iFOBT Mailers - 30/pkg5064 ColoScreen iFOBT Office Pack - 30 each (Collection Tubes, Cassettes and Mailers)

1 Patient sample is collected and transported in a unique collection tube containing stabilizing buffer with the built-in sampling wand.

2 In the laboratory, sample is dispensed from the collection tube directly into the test cassette.

3 Quality control and patient results are read in the window.

Page 36: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

I N T E G R AT E D S O L U T I O N S

Helena

The Touch integrated gel ELP system puts the power of touch technology in your hands

to knock out all your protein, immunofixation, hemoglobin and cholesterol testing quickly

and efficiently. The Touch system is faster and smaller, plus provides integration with the V8

capillary system and ease of interpretation with the Myeloma Module for reporting results.

TO U C H S E R I E S 4

ESH TOUCH SPIFE TOUCH QS TOUCH + 1 2 3

F A S T E R P R O C E S S I N G M Y E L O M A T R A C K I N GTO U C H S C R E E N S

Interactive Webinars are available

to show you how much more efficient

your workflow can be. Schedule today

by emailing [email protected]

Helena O C C U LT B L O O D T E S T S 3 5

COLOCARE

H E L E N A O C C U LT B L O O D T E S T S

COLOSCREENColoScreen offers the sensitivity and specificity of traditional guaiac methods (10 mg/g) at a lower cost.

5076 1000 Singles Lab Pack5072 100 Singles Lab Pack 5077 Developer, 20 x 15 mL 5078 Developer, 50 x 2 mL 5073 80 Triples w/Mailer 5079 Perforated Tape/Developer

COLOSCREEN-ES

5086 100 Singles Lab Pack5085 80 Triples w/Mailer 5088 ES Developer, 20 x 15 mL

ColoScreen-ES is an extra-sensitive (0.3 mg/g feces) guaiac test with vivid color development for easier interpretation.

ColoCARE is the easiest, most economical way to screen for fecal occult bleeding. ColoCARE’s sensitivity is roughly equivalent to traditional guaiac FOBT. Helena also supplies the support materials needed for successful screens. Educational handouts, wall charts, and promotional materials are available free of charge with your ColoCARE order. With ColoCARE, there is no stool handling or laboratory processing.

5651 Office Pack 50 Take-Home Kits, 3 test pads each

5650 Screening Pack 250 Take-Home Kits, 3 test pads each

ColoCARE is clean, simple and effective with higher compliance rates than traditional guaiac slide tests.

Leading medical institutions enjoy great performance, and even greater savings, with ColoScreen and ColoScreen-ES occult blood tests.

Page 37: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

I N T E G R AT E D S O L U T I O N S | A U TO M AT E D P R O C E S S I N G

Helena TO U C H S E R I E S

Labcon D I S P O S A B L E P L A S T I C S 3 6

C-PETTE® AND C-PETTE-E

U-PETTE®

8 0 0 - 2 2 7 - 1 4 6 6 | W W W. L A B C O N . C O M

The new C-Pette and C-Pette-E make

delivering samples into the test cards and

cassettes used by point of care analyzers easy

and efficient, while reducing risk of biohazard

exposure. Original C-Pette features an easy

to insert metal cannula, while the all-plastic

C-Pette-E is a more economical alternative.

C-Pettes are ideal for use with the Abbott

i-STAT® test cartridges. Original C-Pette, 500 pieces – Cat. No. 7630-500-000-9 C-Pette-E, 500 pieces – Cat. No. 7625-500-000-9

U-Pettes provide an easy way to dispense blood

into a test card or cassette, like our Cascade Abrazo

or Abbott’s iSTAT, without uncapping the tube. The

unique tab design allows blood to be dispensed two

different ways as needed.

For larger samples, place the tip of the U-Pette all the way to the bottom of the sample well. Counterpressure with the tabs while pushing down on the tube to dispense sample as needed.

For small volumes, hold the tip over the sample port to dispense sample into the port by using the tabs to counterpressure like a syringe.

i-STAT is a registered trademark of the Abbott Group of Companies

U-Pette, 100 pieces – Cat. No. 7626-540-000-9U-Pette, 500 pieces – Cat. No. 7626-500-000-9

C - P E T T E A N D U - P E T T E A R E A V A I L A B L E D I R E C T L Y F R O M L A B C O N

Page 38: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

HelenaThe Nexus MAX features eight capillaries and six on-board reagent positions that enable full multi-assay functionality and high throughput. A superior sample handling system allows continuous loading of samples with auto-dilutions and auto-preparation of SPIFE sample trays for additional testing by gel electrophoresis.

IFE of Patient on Daratumumab Therapy

• Added to patient sample cup prior to application to bind up the therapeutic monoclonal, removing confusion with pathologic monoclonals

• Expandable to other monoclonal antibody (MAB) drugs like elotuzumab

NEXUS MAX | AUTOMATED CLINICAL CHEMISTRY ANALYZER

SPIFE ANTI-DARA* ALPHA-1 ANTITRYPSIN*

P R O D U C T P R E V I E W S 2

Before SPIFE Anit-Dara

WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS

After SPIFE Anit-DaraS N E A K P E A K !

AT T E N T I O N B L O O D B A N K E R S !

SPIFE Alpha-1 Antitrypsin

• American Lung Association recommends all individuals with COPD or emphysema be tested for Alpha-1 Antitrypsin deficiency

• SPIFE Alpha-1 AT assay separates up to 40 samples per gel

• Identifies all genotypes clinically relevant to lung and liver disease

Anti-Dara also removes interference with antibody screens

*For research use only. June 2019

Labcon D I S P O S A B L E P L A S T I C S 3 7

D I S P O S A B L E L A B WA R E P L A S T I C S

NEW! URINESAFE URINE COLLECTION CUP Gasket for

leak resistance

Finally, a urine cup that can withstand a pneumatic tube

transfer system without springing a leak or breaking the

bank! Those are two of the design specifications of this

new specimen cup now available from Labcon.

Taking cues from their expertise with centrifuge tubes, a

gasket integrated in the lid provides a tight, leak-resistant

seal. High-quality plastic and precision engineering

mean the cup won't shatter during transfer and the

threads mesh cleanly and smoothly allowing the lid to be

screwed on easily.

90 mL, Non-Sterile (100 cups)Cat. No. 4111-840-000-990 mL, Sterile (100 individually wrapped cups)Cat. No. 4111-165-000-9120 mL, Non-Sterile (100 cups)Cat. No. 4112-840-000-9120 mL, Sterile (100 individually wrapped cups)Cat. No. 4112-165-000-9

H-PETTE® AND H-PETTE®-II

3611 H-Pette without Blade, 1000 pieces3612 H-Pette with Blade, 1000 pieces3613 H-Pette Remover3615 H-Pette II without Blade, 1000 pieces

H-Pette and H-Pette II provide a safe and easy way to dispense

a controlled drop of blood to a glass slide for preparing

differential slides.

New H-Pette II features a metal cannula for ease of insertion

through the stopper of collection tubes.

Using H-Pette is simple. Just insert H-Pette into the stopper of

any size blood collection tube, invert tube and transfer a drop of

blood to a glass slide or test cassette. Original molded H-Pettes

are also available with an integral blade for making differential

slides. H-Pettes remain in place in the stopper and are disposed

of with the tubes. They can also be easily removed if necessary.

H - P E T T E S A R E A V A I L A B L E F R O M H E L E N A L A B O R A T O R I E S A T 1 - 8 0 0 - 2 3 1 - 5 6 6 3

Page 39: HELENA LABORATORIES PRODUCT HIGHLIGHTS Catalog 2019.pdf · WALKAWAY AUTOMATION – 552 SPEs IN 6 HOURS After SPIFE Anit-Dara SNEAK PEAK! ATTENTION BLOOD BANKERS! SPIFE Alpha-1 Antitrypsin

H E L E N A L A B O R ATO R I E S

P R O D U C T H I G H L I G H T S

2 0 1 9

549-3025/19

[email protected]