helukabel range-at a glance

52
www.helukabel.in CABLES & WIRES CABLE ACCESSORIES

Upload: malar-vizhi

Post on 28-Oct-2015

54 views

Category:

Documents


0 download

DESCRIPTION

helukabel

TRANSCRIPT

Page 1: Helukabel Range-At a Glance

www.helukabel.in

CABLES & WIRES

CABLE ACCESSORIES

Page 2: Helukabel Range-At a Glance

The Production Windsbach/Nuremberg

HELUKABEL is one of Germany's leading cable companies, boasting an extensive range of cables,

wires, special cables, media technology, cable accessories, as well as Data, Network & Bus Technology

and cable protection systems for robotics & handling systems.

Today we produce for all markets & for every purpose. Our extensive warehouse stock, containing

over 33,000 articles, enable us to deliver your order within extremely short delivery times.

We are also able to design special cables to meet your individual specifications.

Since more than 30 years, HELUKABEL is one of the most successful companies in the field of cables &

wires. Since the establishment in the year 1978, it is our goal to satisfy our customers and to deliver

the required products just in time at the best possible price/performance ratio.

By consistent concentration on a qualitatively high-class product assortment, a multiplicity of product

innovations, own production facilities within the special cable range as well as world-wide warehouse

and service locations, HELUKABEL has attained a supremacy in the market, unusual for the cable

industry.

Page 3: Helukabel Range-At a Glance

Achieving Success through Quality and Innovation

Product certificates documents the tested quality level

of our products

Our aim is to manufacture consistently to quality products By Certifying our products according to

International Standards DIN EN ISO 9001 : 2000 and 14001 : 2004 we meet the required quality

and environmentally - relevant processes. Product certificates issued by accredited institutions

also make it easier for you to evaluate your supplier.

Our continuous quality improvement process eables us not only to maintain a consistently high

quality standard, it also ensures continued development and new product development.

Page 4: Helukabel Range-At a Glance

Flexible Control Cables

Page 5: Helukabel Range-At a Glance

FLEXIBLE CONTROL CABLES

JZ-500 (YSLY-JZ)

(PVC)

H05VV5-F (NYSLYÖ-JZ)

Technical Data : Special PVC insulated, bare copper, fine wire conductor (Class 5), control cable,

adapted to DIN VDE 0245, 0281, 0293, 0295.

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 4000V

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 100; Core Cross Section : 0.5 to 185 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores black with number coding. CE Marked & RoHS compliant.

Technical Data : Special PVC with Oil resistant outer jacket to DIN VDE 0281 Part 13, HD 21.13S1, and

IEC 60227/75, bare copper, fine wire conductor (Class 5), Harmonized control cable

Temp. Range : -40°C to +70°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 2000V, 5 min.

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Core : 2 to 65; Core Cross Section : 0.5 to 50 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Oil resistant to

HD/EN 60811-2-1, Cores black with number coding.

CE Marked & RoHS compliant.

RoHS

VDE R

eg.-N

r.

RoHS

Page 6: Helukabel Range-At a Glance

JZ-600

(PVC)

F-CY-JZ

Technical Data : Special PVC insulated, bare copper, fine wire conductor (Class 5), control cable,

adapted to DIN VDE 0262/12.95 and DIN VDE 0281 part 13

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 600/1000V

Test Voltage : 4000V

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 100; Core Cross Section : 0.5 to 185 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores black with number coding. Outer sheath black with UV resistant.

CE Marked & RoHS compliant.

Technical Data : Special PVC insulated, bare copper, fine wire conductor (Class 5), Tinned Cu. Braid

shielded control cable, adapted to DIN VDE 0245 and DIN VDE 0281 part 13

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 4000V

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 2 to 100; Core Cross Section : 0.5 to 50 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores black with number coding.

CE Marked & RoHS compliant.

RoHS

VDE R

eg.-N

r.

FLEXIBLE CONTROL CABLES

RoHS

VDE R

eg.-N

r.

Page 7: Helukabel Range-At a Glance

(PVC)FLEXIBLE CONTROL CABLES

Y-CY-JZ

SY-JZ

Technical Data : Special PVC insulated, bare copper, fine wire conductor (Class 5), Tinned Cu. Braid

shielded control cable with inner sheath & transparant PVC outer sheath, adapted to

DIN VDE 0245 and DIN VDE 0281 part 13

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 4000V

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 2 to 100; Core Cross Section : 0.5 to 150 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores black with number coding. CE Marked & RoHS compliant.

Technical Data : Special PVC insulated, bare copper, fine wire conductor (Class 5), Galvanised Steel

wire braided control cable with inner sheath & transparant PVC outer sheath, adapted

to DIN VDE 0245 and DIN VDE 0281, 0293 & 0295.

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 4000V

Minimum Bending Radius : 6 X CableØ

Sizes available : Number of Cores : 2 to 100; Core Cross Section : 0.5 to 150 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores black with number coding. CE Marked & RoHS compliant.

RoHS

VDE R

eg.-N

r.

RoHS

VDE R

eg.-N

r.

Page 8: Helukabel Range-At a Glance

Technical Data : Special PUR Sheathed, bare copper, fine wire conductor (Class 5), control cable

adapted to DIN VDE 0245 and DIN VDE 0281

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 4000V

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 50; Core Cross Section : 0.5 to 95 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to UV

radiations, Oxygen, Ozone and hydrolysis, microbes. Increased Oil, coolant & tear

resistant. Cores black with number coding. CE Marked & RoHS compliant.

(PUR)FLEXIBLE CONTROL CABLES

PURÖ-JZ

F-C-PURÖ-JZ

Technical Data : Special PUR Sheathed, bare copper, fine wire conductor (Class 5), Tinned Cu Braid

Shielded control cablead apted to E DIN VDE 0245 part 201 & 102

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 3000V

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 2 to 50; Core Cross Section : 0.5 to 6 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to UV

radiations, Oxygen, Ozone and hydrolysis, microbes. Increased Oil, coolant & tear

resistant. Cores black with number coding. CE Marked & RoHS compliant.

RoHS

RoHS

Page 9: Helukabel Range-At a Glance

(PUR)FLEXIBLE CONTROL CABLES

YÖ-C-PURÖ-JZ

PUR-750

Technical Data : Special PUR Sheathed, bare copper, fine wire conductor (Class 5), Tinned Cu. Braid

shielded control cable with inner & outer sheathed adapted to E DIN VDE 0245

part 202/03.92 & E DIN VDE 0281 part 13

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 4000V

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 2 to 50; Core Cross Section : 0.5 to 95 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to UV

radiations, Oxygen, Ozone and hydrolysis, microbes. Increased Oil, coolant & tear

resistant. Cores black with number coding. CE Marked & RoHS compliant.

Technical Data : Special PUR core insulated & PUR Sheathed, bare copper, fine wire conductor (Class 5),

control cable adapted to DIN VDE 0282 part 10

Temp. Range : -40°C to +80°C ( upto +100°C for short period)

Nominal Voltage : Uo/U 450/750V

Test Voltage : 2500V

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 2 to 25; Core Cross Section : 0.75 to 120 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to UV

radiations, Oxygen, Ozone and hydrolysis, microbes. Oil & fats, Sea & waste water &

vibrations, Kerosene & non-alcoholic fuels. High abrassion resistant. Halogen-Free.

Cores colour coded upto 6 cores & above that number coded

CE Marked & RoHS compliant.

RoHS

RoHS

Page 10: Helukabel Range-At a Glance

FLEXIBLE HALOGEN-FREE CABLES

JZ-500 HMH

MEGAFLEX® 500

Technical Data : Halogen-Free control cable, bare copper, fine wire conductor (Class 5),

adapted to E DIN VDE 0281 part 14 DIN VDE 0281 part 13.

Temp. Range : -40°C to +70°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 2000V

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 65; Core Cross Section : 0.5 to 120 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Low Smoke Zero Halogen (LSOH), extremely fire resistant.

Cores black with number coding. CE Marked & RoHS compliant.

Technical Data : Halogen-Free control cable, bare copper, fine wire conductor (Class 5),

Halogen-Free special polymer insulated. adapted to E DIN VDE 0281 part 14.

Temp. Range : -40°C to +70°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 3000V

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 65; Core Cross Section : 0.5 to 120 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Low Smoke Zero Halogen (LSOH), extremely fire resistant. UV & Ozone resistant.

Cores black with number coding. CE Marked & RoHS compliant.

RoHS

FRNC

RoHS

FRNC

Page 11: Helukabel Range-At a Glance

Technical Data : Halogen-Free control cable, bare copper, fine wire conductor (Class 5),

Tinned Cu. Shielded, adapted to E DIN VDE 0281 part 14 DIN VDE 0281 part 13.

Temp. Range : -40°C to +70°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 2000V

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 25; Core Cross Section : 0.5 to 120 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Low Smoke Zero Halogen ( LSOH), extremely fire resistant.

Cores black with number coding. CE Marked & RoHS compliant.

(SHIELDED)FLEXIBLE HALOGEN-FREE CABLES

JZ-500 HMH-C

MEGAFLEX® 500-C

Technical Data : Halogen-Free control cable, bare copper, fine wire conductor (Class 5),

Halogen-Free special polymer insulated, Tinned Cu Shielded,

adapted to E DIN VDE 0281 part 14.

Temp. Range : -40°C to +70°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 3000V

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 65; Core Cross Section : 0.5 to 120 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Low Smoke Zero Halogen ( LSOH), extremely fire resistant. UV & Ozone resistant.

Cores black with number coding. CE Marked & RoHS compliant.

RoHS

FRNC

RoHS

FRNC

Page 12: Helukabel Range-At a Glance

Data and Computer Cables

Page 13: Helukabel Range-At a Glance

Technical Data : Special PVC insulated, bare copper, fine wire conductor (Class 5), Data Cable,

adapted to DIN VDE 0245 & 0812

Temp. Range : -40°C to +80°C

Nominal Voltage : 350V (upto 0.14 mm²) & 500V (from 0.25 mm²)

Test Voltage : 1200V (Upto 0.25 mm²) & 2000V (from 0.34 mm²)

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 100; Core Cross Section : 0.14 to 1.5 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores colour coded to DIN 47100 without colour repetition

CE Marked & RoHS compliant.

(PVC)FLEXIBLE DATA CABLES

TRONIC (LiYY)

PAAR-TRONIC (LiYY-TP)

Technical Data : Special PVC insulated, bare copper, fine wire conductor (Class 5), cores twisted in

pairs, Data Cable, adapted to DIN VDE 0812 & 0814

Temp. Range : -30°C to +80°C

Nominal Voltage : 350V

Test Voltage : 1200V

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : upto 55 pairs; Core Cross Section : 0.14 to 0.75 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores colour coded to DIN 47100. CE Marked & RoHS compliant.

RoHS

RoHS

Page 14: Helukabel Range-At a Glance

Technical Data : Special PVC insulated, bare copper, fine wire conductor (Class 5), Tinned Cu. Braided

(85% coverage)Data Cable, adapted to DIN VDE 0245 & 0812

Temp. Range : -40°C to +80°C

Nominal Voltage : 350V (upto 0.14 mm²) & 500V (from 0.25 mm²)

Test Voltage : Core to Core - 1200V, Core to Screen - 800V

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 2 to 100; Core Cross Section : 0.14 to 1.5 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores colour coded to DIN 47100 without colour repetition

CE Marked & RoHS compliant.

(PVC-SHIELDED)FLEXIBLE DATA CABLES

TRONIC-CY (LiY-CY)

PAAR-TRONIC-CY (LiY-CY-TP)

Technical Data : Special PVC insulated, bare copper, fine wire conductor (Class 5), cores twisted in

pairs, Data Cable, Tinned Cu. Braided (85% coverage) adapted to DIN VDE 0812 & 0814

Temp. Range : -30°C to +80°C

Nominal Voltage : 350V

Test Voltage : Core to Core - 1200V, Core to Screen - 800V

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : upto 55 pairs; Core Cross Section : 0.14 to 1.5 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores colour coded to DIN 47100. CE Marked & RoHS compliant.

RoHS

RoHS

Page 15: Helukabel Range-At a Glance

Technical Data : Special PE insulated Low Capacitance, bare copper, fine wire conductor (Class 5),

Cores twisted in pairs, each pair individually shielded with plastic coated Aluminium

foil, overall Tinned Cu. shielded (85% coverage) Data Cable for computer,

Temp. Range : -20°C to +80°C

Nominal Voltage : 300V

Test Voltage : Core to Core - 2000V, Core to Screen - 1000V

Minimum Bending Radius : 6 X CableØ

Sizes available : Number of Cores : upto 30 pairs; Core Cross Section : 0.5 to 1.5 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores colour coded to DIN 47100 with colour repetition. CE Marked & RoHS compliant.

(PE - SHIELDED)FLEXIBLE DATA CABLES

EDV-PiMF-CY

PAAR-TRONIC-Li-2YCY

Technical Data : Special PE insulated Low Capacitance, bare copper, Stranded wires, 7-wires, suitable

for Termi-Point® & solder-free connection technique. Cores twisted in pairs,

overall Tinned Cu. shielded (85% coverage) Data Cable for RS 422 & RS 485

Temp. Range : -30°C to +80°C

Nominal Voltage : 250V

Test Voltage : Core to Core - 2000V, Core to Screen - 1000V

Minimum Bending Radius : 7.5 X CableØ

Sizes available : Number of Core upto 10 pairs; Core Cross Section : 0.22 to 0.5 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1.

Cores colour coded to DIN 47100 with colour repetition. CE Marked & RoHS compliant.

RoHS

RoHS

Page 16: Helukabel Range-At a Glance

Cables for Drag Chains

Page 17: Helukabel Range-At a Glance

(PVC)HIGHLY FLEXIBLE CABLES FOR DRAG CHAINS

JZ-HF

Technical Data : Special PVC insulated, highly flexible, Bare Copper fine wire conductor (Class 6),

Cores wrapped with fleece,Control Cable adapted to DIN VDE 0281 part 13.

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 4000V

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 65; Core Cross Section : 0.5 to 16 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores black with number coding. CE Marked & RoHS compliant.

Technical Data : Special PVC insulated, highly flexible, Bare Copper fine wire conductor (Class 6),

Cores wrapped with fleece with PVC inner sheath, Tinned Cu. Shielded Control

Cable adapted to DIN VDE 0281 part 13.

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 4000V

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 2 to 50; Core Cross Section : 0.5 to 16 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Chemical & oil resistant

Cores black with number coding. CE Marked & RoHS compliant.

RoHS

VDE R

eg.-N

r.

JZ-HF-CY

RoHS

VDE R

eg.-N

r.

Page 18: Helukabel Range-At a Glance

(PUR)HIGHLY FLEXIBLE CABLES FOR DRAG CHAINS

PURÖ-JZ-HF

PURÖ-JZ-HF-YCP

Technical Data : Special PUR insulated, highly flexible, Bare Copper fine wire conductor (Class 6),

Cores wrapped with fleece,Control Cable adapted to DIN VDE 0281, 0282 & 0245

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 4000V

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 65; Core Cross Section : 0.5 to 95 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to Oil,

Oxygen, Ozone & hydrolysis. UV-Resistant

Cores black with number coding. CE Marked & RoHS compliant.

Technical Data : Special PUR insulated, highly flexible, Bare Copper fine wire conductor (Class 6),

Cores wrapped with fleece, Tinned Cu Shielded Control Cable with inner sheath

adapted to DIN VDE 0281, 0282 & 0245

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 300/500V

Test Voltage : 4000V

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 2 to 65; Core Cross Section : 0.5 to 16 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to Oil,

Oxygen, Ozone & hydrolysis. UV-Resistant

Cores black with number coding. CE Marked & RoHS compliant.

RoHS

RoHS

Page 19: Helukabel Range-At a Glance

Servo, Feedback & Motor Cables

Page 20: Helukabel Range-At a Glance

SERVO, FEEDBACK & MOTOR CABLES

TOPFLEX® 600-C-PVC

TOPFLEX® 600-C-PUR

Technical Data : Special PVC insulated, flexible, Bare Copper fine wire conductor (Class 5), Tinned Cu

Screened, Motor Power Cable adapted to DIN VDE 0293, 0295 & 0472 Part 804

Temp. Range : -40°C to +80°C

Nominal Voltage : Uo/U 600/1000V

Test Voltage : 4000V

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 4, Core Cross Section : 1.5 to 120 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to Oil,

Cores black with number coding. CE Marked & RoHS compliant.

Technical Data : Special PUR insulated, Highly flexible, Bare Copper fine wire conductor (Class 6),

Tinned Cu Screened, Motor Power Cable adapted to DIN VDE 0293, 0295, 0250 & 0281

Temp. Range : -50°C to +90°C

Nominal Voltage : Uo/U 600/1000V

Test Voltage : 4000V

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 4, Core Cross Section : 1.5 to 120 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to Oil,

abrasion, hydrolysis & microbes. Halogen-Free, Suitable for Drag Chains.

Cores black with number coding. CE Marked & RoHS compliant.

RoHS

RoHS

Page 21: Helukabel Range-At a Glance

SERVO, FEEDBACK & MOTOR CABLES

TOPSERV® 110/120/Feedback-Cables

TOPFLEX®-EMV-2YSLCY-J

Technical Data : Special TPE Core insulated & PUR outer sheathed, Highly flexible, Bare Copper fine ,

wire conductor (Class 6), consisting of Power & seperately screened Control cores,

overall Tinned Cu Screened, Feedback Cable adapted to DIN VDE 0295, 0250 & 0281

Temp. Range : -40°C to +90°C

Nominal Voltage Uo/U : Power Cores : 600/1000V; Control Cores : 300/500V.

Test Voltage : Power Cores : 4000V; Control Core : 1000V.

Minimum Bending Radius : 4 X CableØ

Sizes available : Power Cores : 4C X 1.5 to 4C X 50 mm²

Control Cores : 2 X 1 mm² & 2 X (2 X 1 mm²)

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to Oil,

abrasion, hydrolysis & microbes. Halogen-Free, Suitable for Drag Chains.

CE Marked & RoHS compliant.

Technical Data : Special PE Core insulated & PVC outer sheathed, flexible, Bare Copper fine wire

conductor (Class 5), Double Screened Power cable for frequency Converters.

Temp. Range : -40°C to +70°C

Nominal Voltage Uo/U : Power Cores : 600/1000V.

Test Voltage : 2500V.

Minimum Bending Radius : 5 X CableØ to max 10 X CableØ

Sizes available : 4C X 1.5 to 4C X 185 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1.

Low Mutual Capacitance, Core Colours : Black/Brown/Grey & Green-Yellow.

CE Marked & RoHS compliant.

RoHS

RoHS

Page 22: Helukabel Range-At a Glance

Heat-resistant Cables

Page 23: Helukabel Range-At a Glance

HEAT RESISTANT CABLES

SiHF

HELUTHERM® 145 MULTI

Technical Data : Special Silicon core insulated & Silicon outer sheathed, flexible, Tinned Copper fine

wire conductor (Class 5), heat-resistant Control Cable, adapted to DIN VDE 0250 part 1

Temp. Range : -60°C to +180°C ( Upto 220 °C for short time)

Nominal Voltage Uo/U : 300/500V.

Test Voltage : 2000V;

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 25; Core Cross Section : 0.5 to 35 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Oil & fat resistant.

Halogen-Free, Oxygen & UV resistant. Cores colour coded.

CE Marked & RoHS compliant.

Technical Data : Special Cross-Linked Polyolefin cores & Electron Beam Cross-Linked (EBXL) outer

sheathed, flexible, Tinned Copper fine wire conductor (Class 5), heat-resistant

Control Cable, adapted to DIN VDE 0250 part 1

Temp. Range : -55°C to +145°C

Nominal Voltage Uo/U : 6000/1000V.

Test Voltage : 3500V;

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 1 to 37; Core Cross Section : 0.25 to 95 mm²

Properties : Flame Retardent Non Corrosive (FRNC), Halogen-Free, Oil, UV & abrasion resistant.

Core colour coded upto 5 cores & above that number coded.

CE Marked & RoHS compliant.

RoHS

RoHS

FRNC

Page 24: Helukabel Range-At a Glance

HEAT RESISTANT CABLES

THERMFLEX 180 EWKF

MULTITHERM® 400

Technical Data : Special Silicon core insulated & Silicon outer sheathed, flexible, Tinned Copper fine

wire conductor (Class 5), heat-resistant Control Cable, adapted to DIN VDE 0250 part 1

Temp. Range : -60°C p g to +180°C ( Upto 220 °C for short time)

Nominal Voltage Uo/U : 300/500V.

Test Voltage : 2000V;

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 2 to 20; Core Cross Section : 0.75 to 6 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Oil & fat resistant.

Halogen-Free, Oxygen & UV resistant. Cores colour coded.

CE Marked & RoHS compliant.

Technical Data : Special braided Glass Fibre Silicon impregnated insulation, Nickel plated Copper

finely stranded (ASTM B355), heat-resistant Control Cable.

Temp. Range : -60°C to +400°C ( Upto 500 °C for short time)

Nominal Voltage : 500V.

Test Voltage : 2500V;

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 2 to 7; Core Cross Section : 0.5 to 16 mm²

Properties : Halogen-Free, Asbestos & Cadmium-Free. CE Marked & RoHS compliant.

RoHS

RoHS

Page 25: Helukabel Range-At a Glance

HEAT RESISTANT CABLES

SiHF/GL-P

SiHF-C-Si

Technical Data : Special Silicon core insulated & Silicon outer sheathed, Glass Fibre taped & outer

braiding with Galvanised Steel wire, flexible, Tinned Copper fine wire conductor

(Class 5), heat-resistant Control Cable, adapted to DIN VDE 0250 part 1

Temp. Range : -60°C to +180°C ( Upto 220 °C for short time)

Nominal Voltage Uo/U : 300/500V.

Test Voltage : 2000V;

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 2 to 24; Core Cross Section : 0.5 to 25 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Oil & fat resistant.

Halogen-Free, Oxygen & UV resistant. Cores colour coded.

CE Marked & RoHS compliant.

Technical Data : Special Silicon core insulated & Silicon outer sheathed, Tinned Cu braid shielding

85%, flexible, Tinned Copper fine wire conductor (Class 5), heat-resistant Control

Cable, adapted to DIN VDE 0250 part 1 & Part 816

Temp. Range : -60°C to +180°C ( Upto 220 °C for short time)

Nominal Voltage Uo/U : 300/500V.

Test Voltage : 2000V;

Minimum Bending Radius : 5 X CableØ

Sizes available : Number of Cores : 2 to 25; Core Cross Section : 0.5 to 25 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Oil & fat resistant.

Halogen-Free, Oxygen & UV resistant. Cores colour coded.

CE Marked & RoHS compliant.

RoHS

RoHS

Page 26: Helukabel Range-At a Glance

SINGLE CORE CABLES

H05 V-K / H07 V-K : PVC insulated Fine wire stranded flexible Single Core cables.

Range : 0.5 mm² to 240 mm², 300/500V & 450/750V

H05Z-K / H07Z-K : Rubber insulated Fine wire stranded flexible Single Core cables.

Range : 0.5 mm² to 240 mm², 300/500V & 450/750V

Halogen-Free.

HELUTHERM® 145 : Cross-Linked Halogen Free Fine wire stranded flexible.

Range : 0.25 mm² to 240 mm², 300/500V & 450/750V

Temp. Range : -55°C to + 145 °C

NSGAFÖU 3KV : Special Rubber insulated fine wire single core, 1.8/3 KV.

H01N2-D : Harmonized Welding Cable, 100V, Rubber insulated, 10 mm² to 240 mm²

Page 27: Helukabel Range-At a Glance

Data, Network and Bus Technology

Page 28: Helukabel Range-At a Glance

DATA, NETWORK & BUS CABLES

Fibre Optic Cables HELUCOM®

Copper Data Cables HELUKAT®

RoHS A-DF(ZN)2Y

RoHS A-DQ(ZN)B2Y, central

RoHS A-DF(ZN)2Y(SR)2Y

RoHS FTP

HELUKAT® 155 FTP 4 X 2 X AWG 24/1 PVC CAT 5e

Page 29: Helukabel Range-At a Glance

DATA, NETWORK & BUS CABLES

Copper Data Cables HELUKAT®

BUS Cables

RoHS S-STP

RoHS S-FTP flex

RoHS PROFIBUS L2 Indoor

PROFIBUS L2 1 X 2 X 0.64 mm, UL Style 2571

HELUKAT® 200 S-FTP 4 X 2 X AWG 26/7 FRNC, CAT 5e

HELUKAT® 450 S-STP 4 X 2 X AWG 24/1 FRNC, CAT 6

Page 30: Helukabel Range-At a Glance

Cables according to

International Approvals

Page 31: Helukabel Range-At a Glance

CABLES ACCORDING TO INTERNATIONAL APPROVALS

JZ-603/JZ-603-CY

Approvals : UL-Style 2587, HD 21.13 S1, HAR, CSA, 90°C, 600V.

JZ-604 TC TRAY CABLE

Command Cable UL (LiYCY-TP)

Approvals : UL-Standard 1277, USA NFPA79, edition 2007, TRAY CABLE, 90°C, 600V.

Approvals : UL-Style 2464, 1061/1729, 80°C, 300V.

FIVENORM HAR-UL-CSA-AWM-MTW

Approvals : UL-Style 1015/UL-Standard 1063, 105°C, 600V, PVC Single Core.

RoHS

RoHS

RoHS

RoHS

Page 32: Helukabel Range-At a Glance

HEAVY DUTY RUBBER & TRAILING CABLES

H07 RN-F

NSHTÖU

Technical Data : Rubber core insulated & Rubber outer sheathed, flexible, bare Copper fine wire

conductor (Class 5), heavy duty Cable, adapted to DIN VDE 0282 part 4, HD 22.4 S4

BS 7919 & IEC 60245 - 4

Temp. Range : -30°C to +60°C

Nominal Voltage Uo/U : 450/750V & for protected & fixed installation : 600/1000V.

Test Voltage : 2500V;

Minimum Bending Radius : 4 X CableØ

Sizes available : Number of Cores : 1 to 24; Core Cross Section : 1.5 to 500 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Ozone & Weather

resistant, Harmonized. Cores colour coded upto 5 cores & above that number coded.

CE Marked & RoHS compliant.

Technical Data : Rubber core insulated & Neoprene outer sheathed, flexible, Tinned Copper fine wire

conductor (Class 5), Special Crane-Drum-Cable dapted to DIN VDE 0250 part 814.

Suspension strains & textile braiding as strain & Torsion relieving elements.

Temp. Range : -40°C to +70°C

Nominal Voltage Uo/U : 600/1000V.

Test Voltage : 2500V;

Minimum Bending Radius : 7.5 X CableØ

Sizes available : Number of Cores : 3 to 50; Core Cross Section : 1.5 to 95 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to Ozone,

Oils, Fats, Acids & Chemicals. Cores colour coded upto 5 cores & above number coded.

UV-Resistant & suitable for frequent winding & unwinding.

CE Marked & RoHS compliant.

RoHS

RoHS

Page 33: Helukabel Range-At a Glance

Power Cables, Security Cables

and Medium Voltage Cables

Page 34: Helukabel Range-At a Glance

POWER & MEDIUM VOLTAGE CABLES

NYY-J/NYY-O

NYCWY

Technical Data : PVC core insulated & PVC outer sheathed, bare Copper Solid or stranded Conductor

(CL-1 or CL-2) Power Cable adapted to DIN VDE 0276 part 603, HD 603.1 & IEC 60502

Temp. Range : -40°C to +70°C

Nominal Voltage Uo/U : 600/1000V AC & 1.8 KV DC.

Test Voltage : 4000V.

Minimum Bending Radius : 12 X CableØ

Sizes available : Number of Cores : 1 to 61; Core Cross Section : 1.5 to 630 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to

Suitable for laying Underground, in water, open air in power stations.

Cores colour coded to DIN VDE 0293-308, 0276 part 603.

Technical Data : PVC core insulated & PVC outer sheathed, bare Copper Solid or stranded Conductor

(CL-1 or CL-2), concentric concuctor, inner layer of corrugated copper wires, and

copper tape, Power Cable adapted to DIN VDE 0276 part 603, HD 603.1 & IEC 60502

Temp. Range : -40°C to +70°C

Nominal Voltage Uo/U : 600/1000V AC & 1.8 KV DC.

Test Voltage : 4000V.

Minimum Bending Radius : 12 X CableØ

Sizes available : Number of Cores : 1 to 61; Core Cross Section : 1.5 to 630 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to

Suitable for laying Underground, in water, open air in power stations.

Cores colour coded to DIN VDE 0293-308, 0276 part 603.

CE Marked & RoHS compliant.

RoHS

RoHS

Page 35: Helukabel Range-At a Glance

POWER & MEDIUM VOLTAGE CABLES

N2XSY 6/10KV, 12/20KV, 18/30KV

N2XSEY 3 X ...6/10KV

Technical Data : XLPE core insulated & Special PVC outer sheathed, bare Copper stranded Conductor

acc. To HD 383, Copper wire braid screened Single Core Power Cable adapted to DIN

VDE 0276 part 620, HD 620 S1 & IEC 60502

Temp. Range : -5°C to +90°C

Nominal Voltage Uo/U : 6/10KV, 12/20KV, 18/30KV.

Test Voltage : for 6/10KV = 15KV; 12/20KV = 30 KV; 18/30KV = 45KV.

Minimum Bending Radius : 15 X CableØ

Sizes available : 1 X 35 mm² to 1 X 500 mm².

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to

Suitable for laying Underground, in water, open air in power stations.

Technical Data : XLPE core insulated & Special PVC outer sheathed, bare Copper stranded Conductor

to DIN VDE 0276 acc. To DIN VDE 0295 Cl-2, Copper wire braid screened 3 - Core Power

Cable adapted to VDE 0276, IEC 60502

Temp. Range : -5°C to +90°C

Nominal Voltage Uo/U : 6/10KV.

Test Voltage : 15KV AC & 48 KV DC.

Minimum Bending Radius : 15 X CableØ

Sizes available : 3 X 25 mm² to 3 X 300 mm².

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to

Suitable for laying Underground, in water, open air in power stations.

RoHS

RoHS

Page 36: Helukabel Range-At a Glance

Robotic Cables

Page 37: Helukabel Range-At a Glance

ROBOTIC CABLES

ROBOFLEX RECYCLE

ROBOFLEX 2001/2001-C

Technical Data : TPE core insulated & Special mix outer sheathed, flexible, bare Copper fine wire

conductor 42 X 0.10 mm Robotic Cable, UL/cUL approved.

Temp. Range : -40°C to +120°C

Nominal Voltage : 300V.

Test Voltage : 2000V;

Minimum Bending Radius : 7.5 X CableØ

Sizes available : Number of Cores : 3 to 8; Core Cross Section : 0.25 to 0.5 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to

Oil, acids, alkalis. Weld & splatter resistant. UV & abrasion resistant.

CE Marked & RoHS compliant.

Technical Data : TPE core insulated & PUR outer sheathed, flexible, bare Copper extra fine wire

conductor (Class -5 & Class-6) Robotic Cable, adapted to DIN VDE 0245, 0250, 0282

Temp. Range : -40°C to +80°C

Nominal Voltage : 350V (Upto 0.34 mm²); 300/500V ( above 0.5 mm²)

Test Voltage : 1500V (upto 0.34 mm²) & 3000V (above 0.5 mm²)

Minimum Bending Radius : 7.5 X CableØ

Sizes available : Number of Core 3 to 25; Core Cross Section : 0.25 to 35 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to

Oil, fats, oxygen, ozone, microbes. UV & abrasion resistant.

Loadable under torsion stress ±360°/meter. Low adhesion.

CE Marked & RoHS compliant.

RoHS

RoHS

Page 38: Helukabel Range-At a Glance

FLAT CABLES

PVC-Flat ( H05 VVH6-F/H07 VVH6-F)

NEO-Flat (NGFLGÖU)

Technical Data : PVC core insulated & PVC outer sheathed, flexible, bare Copper fine wire

conductor (Class-5) flat Cable adapted to EN 50214 & HD 359 S2.

Temp. Range : -40°C to +80°C

Nominal Voltage Uo/U : 300/500V (upto 1 mm²) & 450/750V ( 1.5 mm² & above)

Test Voltage : 2000V (upto 1 mm²) & 2500V ( 1.5 mm² & above).

Minimum Bending Radius : 10 X Cable thickness.

Sizes available : Number of Cores : 4 to 24; Core Cross Section : 0.75 to 70 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to

Oil & chemicals. Highly flexible. Small bending radius.

Cores black with number coding. CE Marked & RoHS compliant.

Technical Data : Rubber core insulated & Neoprene rubber outer sheathed, flexible, bare Copper

fine wire conductor (Class-5 & Class-6) flat Cable adapted to DIN VDE 0250 part 809.

Temp. Range : -40°C to +80°C

Nominal Voltage Uo/U : 300/500V

Test Voltage : 3000V

Minimum Bending Radius : 10 X Cable thickness.

Sizes available : Number of Cores : 4 to 24; Core Cross Section : 1.5 to 120 mm²

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Resistant to

Oil & chemicals. Highly flexible. Small bending radius.

Cores black with number coding. CE Marked & RoHS compliant.

RoHS

RoHS

Page 39: Helukabel Range-At a Glance

COAXIAL CABLES

RG-COAXIAL CABLES

HALOGEN-FREE RG-COAXIAL CABLES

Cable Types : RG-6/U, RG-8/U, RG-11/U, RG-58/U, RG-59/U, RG-62/U, RG-71/U, RG-174/U

RG-178/U, RG-179/U, RG-213/U, RG-214/U, RG-215/U, RG-216/U, RG-316/U.

Standards : RG-Coaxial Cables are in accordance with US Military specifications MIL-C-17.

Cable Types : RG-11/U, RG-58/U, RG-59/U, RG-62/U, RG-71/U, RG-213/U, RG-214/U.

Standards : RG-Coaxial Cables are in accordance with US Military specifications MIL-C-17.

Properties : H-Outer Jacket = Halogen-Free material (HM2)

FRNC = Flame Retardent Non-Corrosive.

RoHS

RoHS

FRNC

Page 40: Helukabel Range-At a Glance

Compensating Cables

Standard appliacble : DIN 43713

Thermo-Pair Types & Materials :

L : Fe-CuNi (Ko)

K : SoNiCr-SoNi

S : SoPtRh-SoPt

U : Cu-CuNi (Ko)

J : Fe-CuNi

Insulation Materials & Temperature Range :

1. PVC-PVC : -10°C to +80°C

2. PVC-PVC-Galv. Steel Wire braided : -10°C to +80°C

3. Silicon - Silicon : -60°C to +180°C

4. Silicon - Silicon -Galv. Steel Wire braided : -60°C to +180°C

5. Glass Filament - Glass Filament Braided : -60°C to +200°C

6. HELUFLON®-FEP - HELUFLON®-FEP : -100°C to +200°C

Sizes Available :

Single Pair ( 2 X 1.5 mm²), Multi-paired - 2 Pairs to 20 pairs X 1.5 mm²

Single Pair ( 2 X 0.22 mm², 2 X 0.5 mm², 2 X 0.75 mm²)

Multi-Paired ( 4 X 0.22 mm²)

Test Voltage :

Core / Core : 500V

Core / Screen : 500V

Screen / Screen : 500V

RoHS

AN 9-2 LSY 2X1, 5

AE 9-2 LS 2X1, 5

AC 12 L 2X1, 5

AP 9-4 LSY 4X1, 5

AF 12 2X1, 5

AN 1 L

Page 41: Helukabel Range-At a Glance

SPIRAL CABLES

PVC Spiral Cables

Sizes available : 2 X 0.75 mm² to 3 X 1.5 mm²

Spiral Lengths : 200mm /400mm/600mm/800mm/1000mm/1200mm/1400mm.

Expansion Ratio : 1 : 3

Straight Ends length ( mm) : 200/200

PUR Spiral Cables Black.

Sizes available : 2 X 0.75 mm² to 7 X 1.5 mm² & 3 X 2.5 mm²

Spiral Lengths : 500mm /1000mm/1400mm/2000mm/3000mm

Expansion Ratio : 1 : 4

Straight Ends length ( mm) : 200/200

PUR Elektronic Spiral Cables Screened

Sizes available : 2 X 0.14 mm² to 12 X 0.5 mm²

Spiral Lengths : 300mm /400mm/500mm/1000mm

Expansion Ratio : 1 : 4

Straight Ends length ( mm) : 200/200

Page 42: Helukabel Range-At a Glance

CABLES FOR PHOTOVOLTAIC &

WIND POWER STATIONS

Page 43: Helukabel Range-At a Glance

CABLES FOR PHOTOVOLTAIC

SOLARFLEX®-X PV1-F

Technical Data : Crosse-Linked Special Compound insulated, Tinned Copper finely stranded Conductor (Class-5) Double insulated cable for photovoltaic.

Temp. Range : -40°C to +90°C

Nominal Voltage : Uo/U : 0.6/1.0 KV AC & 1800V DC

Test Voltage : 10000V AC

Minimum Bending Radius : 4 X CableØ

Sizes available : 1 X 2.5 mm² to 1 X 95 mm².

Properties : Self-extinguishing and flame retardent according to IEC 60332-1. Halogen-Free,

Resistant to UV, Ozone Weather & Hydrolysis.

Approved with VDE & TÜV (2 PfG 1169/08.2007)

Resistant to Short Circuit upto 250°C. Anticipated service life 25 years.

Part No. No.cores xcross-sec. mm²

Outer Øapp. mm

Cop. weightkg / km

Weightapp. kg / km

Jacketcolour

704225 1 x 2,5 4,5 24,0 55 black

704226 1 x 4 5,2 38,4 85 black

704227 1 x 6 5,9 57,6 95 black

704228 1 x 10 6,9 96,0 110 black

704229 1 x 16 8,3 153,6 170 black

704230 1 x 25 10,0 240,0 295 black

704231 1 x 35 11,0 336,0 395 black

704232 1 x 50 13,0 480,0 630 black

704233 1 x 70 15,3 672,0 850 black

704234 1 x 95 17,0 912,0 1200 black

Page 44: Helukabel Range-At a Glance

WK-SERIES

The perfect & individual Solution

for any application in the

wind power Industry

● NacelleCables with increased Oil & Heat Resistance

● LoopAll the wires subject to torsion have been testedin our test tower for 18000 torsion cycles

● TowerFlexible aluminium as well as copper cable &Fibre optics wires.

International approvals :UL, CSA, FT4, CE, VDE and WTTCStandard cross sections available Ex-Stock.

CABLES FOR WIND POWER STATION

Page 45: Helukabel Range-At a Glance

CABLE ACCESSORIES & PROTECTION

SYSTEMS

Page 46: Helukabel Range-At a Glance

CABLE GLANDS

Plastic Cable Glands

Brass Cable Glands

Stainless Steel Cable Glands

®HELUTOP HT

®HELUTOP HT-MS

®HELUTOP HT-E

Page 47: Helukabel Range-At a Glance

CABLE CONDUITS

HELUcond PA6 (Polyamide PA 6 Plastic Conduits)

SPR-EDU-AS (Metallic Conduit with Steel Wire Braiding)

RoHS

RoHS

Page 48: Helukabel Range-At a Glance

CABLE CONDUITS

HELUcond Jumbo-PA6 (Size : 70 mm & 95 mm)

CO-PA (Polyamide Split Conduits)

RoHS

RoHS

Page 49: Helukabel Range-At a Glance

CONDUIT ACCESSORIES

HSSV Conduit Gland Straight

SH / SHV Conduit Holder

RoHS

RoHS

HSSV Conduit Gland Elbow 90°

(Polyamide PA6)

Page 50: Helukabel Range-At a Glance

INTERNATIONAL STANDARDS

HAR

GOST-R

ChinaCompulsorycertification

Germanischer Lloyd

UL-CSA

Page 51: Helukabel Range-At a Glance

WORLDWIDE

Headquarters

HELUKABEL® GmbH

Dieselstrase 8 - 12 D-71282, Hemmingen, Germany.

Phone : +49-7150-9209

Fax : +49-7150-8884

Email : [email protected]

HELUKABEL BRANCHES

Germany

Switzerland

Sweden

Netherlands

Czech Republic

France

Italy

Belgium

Poland

Turkey

Slovakia

South Korea

Singapore

USA

China

India

Thailand

Russia

South Africa

Malaysia

Exclusive Represntatives

Page 52: Helukabel Range-At a Glance

HELUKABEL INDIA PRIVATE LIMITED

F-305, Kailash Industrial Complex,

Hiranandani Link Road, Vikhroli (w),

Mumbai - 400079

Email : [email protected]

Web : www.helukabel.in

Tel : +91-22-25185849

Fax : +91-22-25185839

The Logistic Centre Hemmingen