hensel demo pdf - solarmdgdata.solar.eu › prd › media › 3c0a11e00a61427ea75315e066844...weight...

3
without terminals 10 elastic membranes, closed cable entries, sealing range Ø 6.5-18 mm with cable retention (2 pc.) for cable tie up to 6.5 mm width colour: grey, RAL 7035 for normal environment and protected outdoor material PS (Polystyrene) Degree of protection: IP 55 mounting width 69 mm mounting height 79 mm max. installation depth 37 mm width 98 mm height: 98 mm depth 52 mm Weight 0,116 kg in accordance with IEC 60 670-22 Drawings Dimension drawing Cable entry via elastic membranes DE 9350 Page 1 of 3 Gustav Hensel GmbH & Co. KG * Gustav -Hensel-Str. 6 * 57368 Lennestadt * Germany * Telef on: +49 (0)2723/609-0 * Fax: +49 (0)2723/60052 * Date: June 20. 2016

Upload: others

Post on 27-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: hensel demo pdf - Solarmdgdata.solar.eu › PRD › Media › 3c0a11e00a61427ea75315e066844...Weight 0,116 kg in accordance with IEC 60 670-22 Drawings Dimension drawing Cable entry

without terminals10 elastic membranes, closed cable entries, sealing range Ø 6.5-18 mmwith cable retention (2 pc.) for cable tie up to 6.5 mm widthcolour: grey, RAL 7035for normal environment and protected outdoor

material PS (Polystyrene)

Degree of protection: IP 55

mounting width 69 mm

mounting height 79 mm

max. installation depth 37 mm

width 98 mm

height: 98 mm

depth 52 mm

Weight 0,116 kg

in accordance with IEC 60 670-22

Drawings

Dimension drawing

Cable entry via elastic membranes

DE 9350

Page 1 of 3Gustav Hensel GmbH & Co. KG * Gustav -Hensel-Str. 6 * 57368 Lennestadt * Germany * Telef on: +49 (0)2723/609-0 * Fax: +49 (0)2723/60052 * Date: June 20. 2016

Page 2: hensel demo pdf - Solarmdgdata.solar.eu › PRD › Media › 3c0a11e00a61427ea75315e066844...Weight 0,116 kg in accordance with IEC 60 670-22 Drawings Dimension drawing Cable entry

Detail mass

Box walls

Operating and ambient conditionsApplication area Suitable for indoor installation and outdoor installation, protected

against weather influences

Ambient temperature Maximum value + 40 °C Minimum value - 25 °C

Fire protection in the event of internal faults Demands placed on electrical devices from standards and laws Minimum requirements - Glow wire test in accordance with IEC 60695-2-11: - 650°C for boxes and cable glands - 850°C for parts of insulating material necessary to retain currentcarrying parts in position

Burning behaviour Glow wire test IEC 60695-2-11: 750 °C UL Subject 94: V-2 flame-retardant self-extinguishing

Degree of protection against mechanical load IK07 (2 Joule)

Toxic behaviour halogen-free silicone-free "halogen-free" in accordance with the examination of the cablesand insulated wires - corrosiveness of fumes - as per IEC 60 754-2

Cable entry via elastic membranes

DE 9350

Page 2 of 3Gustav Hensel GmbH & Co. KG * Gustav -Hensel-Str. 6 * 57368 Lennestadt * Germany * Telef on: +49 (0)2723/609-0 * Fax: +49 (0)2723/60052 * Date: June 20. 2016

Page 3: hensel demo pdf - Solarmdgdata.solar.eu › PRD › Media › 3c0a11e00a61427ea75315e066844...Weight 0,116 kg in accordance with IEC 60 670-22 Drawings Dimension drawing Cable entry

Note: For material properties see technical data.

Cable entry via elastic membranes

DE 9350

Page 3 of 3Gustav Hensel GmbH & Co. KG * Gustav -Hensel-Str. 6 * 57368 Lennestadt * Germany * Telef on: +49 (0)2723/609-0 * Fax: +49 (0)2723/60052 * Date: June 20. 2016