high pressure filters - hydac technology · pdf filef1 high ressure filters pn#02081318 /...
TRANSCRIPT
F1
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
High Pressure Filters3000-6000 psiRobust carbon steel/ductile iron construction filters, provide reliability in demanding industrial applications. Inline, manifold-mount, reverse-flow, bi-directional-flow configurations provide flexibility to accommodate any application. Duplex filters allow for uninterrupted operation during element change-out.
F2
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction Gearboxes
Industrial
Pulp & Paper
Offshore
Railways
CommercialMunicipal
Shipbuilding
PowerGeneration
Steel / HeavyIndustry
Features• Non-welded housing design reduces stress concentrations and
prevents fatigue failure.• Choice of NPT, BSPP, SAE straight thread O-ring boss, and SAE
4-bolt flange porting (sizes 60 - 1320) to allow easy installation with maximum flexibility.
• O-ring seals are used to provide positive, reliable sealing. Choice of O-ring materials (nitrile rubber, fluorocarbon elastomer, and ethylene propylene rubber) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.
• Screw-in bowl or lid (on 2-pc. bowls) mounted below the filter head requires minimal clearance to remove the element for replacement and contaminated fluid cannot be washed downstream when element is serviced.
• HYDAC Differential Pressure Indicators have no external dynamic seal. This results in a high system reliability due to magnetic actuation, thus eliminating a potential leak point.
• A poppet-type bypass valve located in the filter head provides positive sealing during normal operation and fast opening during cold starts and flow surges. (Optional non-bypass available)
• For special finishes and coatings – consult HYDAC for minimum quantities, availability and pricing.
• Fatigue pressure ratings equal maximum allowable working pressure rating.
DF SeriesInline Filters6090 psi • up to 200 gpm
A
B
Technical SpecificationsMounting Method 4 mounting holesPort Connection 30 60/110 160/240/280
330/660/1320
SAE-8, 1/2” NPT, 1/2” BSPPSAE-12, 3/4” NPT, 3/4” BSPP 3/4” SAE, Code 62SAE-20, 1 1/4” NPT, 1 1/4” BSPP 1 1/4” SAE, Code 62SAE-24, 1 1/2” NPT, 1 1/2” BSPP2” SAE Flange Code 62
Flow Direction Inlet: Side Outlet: SideConstruction Materials Head Bowl (30-660) Housing/Bowl (660-1320 - 2.0) Cap/Lid (660-1320 type)
Ductile ironSteelSteelSteel
Flow Capacity 30 60 110 160 240 280 330 660 1320
8 gpm (30 lpm)16 gpm (60 lpm)29 gpm (110 lpm)42 gpm (160 lpm)63 gpm (240 lpm)74 gpm (280 lpm)87 gpm (330 lpm)174 gpm (660 lpm)200 gpm (757 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue Pressure
6090 psi (420 bar)6090 psi (420 bar) @ 1 million cycles
Burst Pressure 3060/110160/240/280330/660/1320
15950 psi (1100 bar)17400 psi (1200 bar)17110 psi (1180 bar)15080 psi (1040 bar
Element Collapse Pressure RatingBH4HC, VON, W/HC
3045 psid (210 bar)290 psid (20 bar)
Fluid Temp. Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.Indicator Trip Pressure��∆P = 29 psid (2 bar) -10% (optional)��∆P = 72 psid (5 bar) -10% (standard)��∆P = 116 psid (8 bar) -10% (optional non bypass)
Bypass Valve Cracking Pressure��∆P = 43 psid (3 bar) +10% (optional)��∆P = 87 psid (6 bar) +10% (standard) Non Bypass Available
F3
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeDF ON 30 T B 5 D 1 . X / 12 - V B6 L24.
Filter Type DF = Inline filter
Element Media ON = Optimicron® BH/HC = Betamicron® (High Collapse) W/HC = Wire Mesh V = Metal Fiber
Size 30, 60, 110, 160, 240, 280, 330, 660, 1320
Pressure Range T = 420 bar
Size and Nominal Connection B = 1/2” Threaded (size 30 only) I = 3/4” SAE Code 62 Flange (sizes 60-140 only) C = 3/4” Threaded (sizes 60-140 only) J = 1 1/4” SAE Code 62 Flange (sizes 160-280 only) E = 1 1/4” Threaded (sizes 160-280 only) L = 2” SAE Code 62 Flange (sizes 330-1320 only) F = 1 1/2” Threaded (sizes 330-1320 only)
Filtration Rating (microns) 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = BH/HC 25, 74, 149 = W/HC 3, 5, 10, 20 = V
Type of ∆P Clogging Indicator A, B, BM, C, D (others available upon request)
Type Number 1 = One piece bowl (sizes 30-660 only) 2 = Two piece bowl (sizes 660-1320 only) 3 = Upside down mount (two-piece bowl) - (sizes 330-1320)
Modification Number (latest version always supplied)
Port Configuration 0 = BSPP 3 = NPT ports – NPT ported filters will be SAE with adaptors in each port 12 = SAE straight thread O-ring boss ports 16 = SAE flange ports (sizes 60-1320 only)
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Bypass Valve (omit) = Non-bypass B3 = Bypass (3 bar) B6 = Bypass (6 bar)
Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids SO155H = Modification of BH4HC (High Collapse) Element For Phosphate Esters SO184 = G-1/2 Drain in Bowl Option For Sizes 60 - 280 (comes standard for sizes 330, 660, & 1320) W = “VD…” indicator modified with a brass piston for use with High water based emulsions/solutions (HFA) & (HFC)
or when using “V” elements L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100ºF (C and D indicators only) cRUus = Electrical Indicators with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation
Replacement Element Model Code0030 D 005 ON / V .
Size 0030, 0060, 0110, 0160, 0240, 0280, 0330, 0660, 1320
Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 1, 3, 5, 10, 15, 20 = ON 25, 74, 149 = W/HC 3, 5, 10, 20 = V
Element Media BH4HC, ON, W/HC, V
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EP = Ethylene propylene rubber (EPR)
Supplementary Details SO263 = (same as above) W = Modication of “V” elements for use with oil water
emulsions (HFA) and water polymer solutions (HFC) usually polyglycol
SFREE = (same as above)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Clogging Indicator Model CodeVD 5 D . X / V L24 .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 15 psid (1 bar) & 116 psid (8 bar) available upon request
Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch – SPDT D = Electric switch and LED light – SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EP = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicators with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with High water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F4
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 30
Weight (lbs.) 5.1
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DF 30
2.7369.3
1.5038
for element removalClearance required
[2.95]
Mounting Holes [0.24]
←
75
INLET
10-32UNF-2B IN. x 6 DP
OUTLET
1/2" Port4 Places
2.68 68
1.77 45
1.1830
Indicator Port G 1/2"
1/2" NPT optional w/ adapters3/4-16UNF-2B IN.2 Places
Optional G1/4"Drain Port
762.99
2.06
6 0.24
168
52.2
6.61
HEX 0.9424
F5
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 60 110 160 240 280 330
Weight (lbs.) 10 12 22.8 26.1 36 54.1
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DF 60-330
c1
c2
Flange2 Places
d5 x †2
G 1/2"Indicator Port
OUTLET INLET
Optional G 1/2"Drain Port
h2
HEX
d2
h1
0.24
6
requiredfor element
removal
Clearanceh4
d32 Places
b1
b3
b4
d1 b2
Mounting Holesd4 x †1
4 Places
F6
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size b1 b2 b3 b4 c1 c2 d1 d2d3
NOM d4* d5 h1 h2 h4 HEX †1 †260...C...
1.X(3.54)
90(2.8) 71
(2.2) 56
(1.26) 32 - - (3.39)
86(2.68)
683/4"
1/4-28UNF- 2B
M6x1.0
- (7.22) 183.5
(1.57) 40
(3.35) 85
(1.06) 27
(0.35) 9 -
60...I... 1.X
(3.50) 89
(2.8) 71
(2.2) 56
(1.26) 32
(2.00) 50.8
(0.94) 23.8
(3.39) 86
(2.68) 68
3/8-16UNC- 2B M10 X 1.5
(7.22) 183.5
(1.57) 40
(3.35) 85
(1.06) 27
(0.35) 9
(0.59) 15
110...C... 1.X
(3.54) 90
(2.8) 71
(2.2) 56
(1.26) 32 - - (3.39)
86(2.68)
683/4"
1/4-28UNF- 2B
M6x1.0
- (9.88) 251
(1.57) 40
(3.35) 85
(1.06) 27
(0.35) 9 -
110...I... 1.X
(3.50) 89
(2.8) 71
(2.2) 56
(1.26) 32
(2.00) 50.8
(0.94) 23.8
(3.39) 86
(2.68) 68
3/8-16UNC- 2B M10 X 1.5
(9.88) 251
(1.57) 40
(3.35) 85
(1.06) 27
(0.35) 9
(0.59) 15
160...E... 1.X
(4.92) 125
(3.74) 95
(3.35) 85
(1.38) 35 - - (4.69)
119(3.74)
951-
1/4"
3/8-24UNF- 2B
M10x1.5
- (9.57) 243
(1.85) 47
(4.13) 105
(1.26) 32
(0.55) 14 -
160...J... 1.X
(4.92) 125
(3.74) 95
(3.35) 85
(1.38) 35
(2.63) 66.7
(1.25) 31.8
(4.69) 119
(3.74) 95
1/2-13UNC- 2B
M14 X 2
(9.57) 243
(1.85) 47
(4.13) 105
(1.26) 32
(0.55) 14
(0.75) 19
240...E... 1.X
(4.92) 125
(3.74) 95
(3.35) 85
(1.38) 35 - - (4.69)
119(3.74)
951-
1/4"
3/8-24UNF- 2B
M10x1.5
- (11.91) 302.5
(1.85) 47
(4.13) 105
(1.26) 32
(0.55) 14 -
240...J... 1.X
(4.92) 125
(3.74) 95
(3.35) 85
(1.38) 35
(2.63) 66.7
(1.25) 31.8
(4.69) 119
(3.74) 95
1/2-13UNC- 2B
M14 X 2
(11.91) 302.5
(1.85) 47
(4.13) 105
(1.26) 32
(0.55) 14
(0.75) 19
280...E... 1.X
(4.92) 125
(3.74) 95
(3.35) 85
(1.38) 35 - - (4.69)
119(3.74)
951-
1/4"
3/8-24UNF- 2B
M10x1.5
- (19.06) 484
(1.85) 47
(4.13) 105
(1.26) 32
(0.55) 14 -
280...J... 1.X
(4.92) 125
(3.74) 95
(3.35) 85
(1.38) 35
(2.63) 66.7
(1.25) 31.8
(4.69) 119
(3.74) 95
1/2-13UNC- 2B
M14 X 2
(19.06) 484
(1.85) 47
(4.13) 105
(1.26) 32
(0.55) 14
(0.75) 19
330...F... 1.X
(6.30) 160
(5.24) 133
(4.53) 115
(2.36) 60 - - (6.42)
163(5.12) 130
2"1/2-
20UNF- 2B M12x1.75
- (12.16) 309
(2.05) 52
(4.53) 115
(1.42) 36
(0.67) 17 -
330...L... 1.X
(6.30) 160
(5.24) 133
(4.53) 115
(2.36) 60
(3.81) 96.8
(1.75) 44.5
(6.42) 163
(5.12) 130
3/4-10UNC- 2B M2O X 2.5
(12.16) 309
(2.05) 52
(4.53) 115
(1.42) 36
(0.67) 17
(0.98) 25
330...F... 2.X
(6.30) 160
(5.24) 133
(4.53) 115
(2.36) 60 - - (6.42)
163(5.12) 130
2"1/2-
20UNF- 2B M12x1.75
- (12.16) 309
(2.05) 52
(7.09) 180
(1.42) 36
(0.67) 17 -
330...L... 2.X
(6.30) 160
(5.24) 133
(4.53) 115
(2.36) 60
(3.81) 96.8
(1.75) 44.5
(6.42) 163
(5.12) 130
3/4-10UNC- 2B M2O X 2.5
(12.16) 309
(2.05) 52
(7.09) 180
(1.42) 36
(0.67) 17
(0.98) 25
*d4 - UN Threads for SAE (/12) & Flanged (/16) ports - M Threads for BSPP ports & Flanged metric ports
Dimensions DF 60-330 (cont’d)
Notes
F7
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size b1 b2 b3 b4 c1 c2 d1 d2d3
NOM d4* d5 h1 h2 h4 HEX †1 †2660...F...
1.X(6.3) 160
(5.24) 133
(4.53) 115
(2.36) 60 - - (6.42)
163(5.12) 130
1- 1/2" 1/2-
20UNF- 2B M12x1.75
- (18.93) 481
(2.05) 52
(4.53) 115
(1.42) 36
(0.67) 17 -
660...L... 1.X
(6.3) 160
(5.24) 133
(4.53) 115
(2.36) 60
(3.81) 96.8
(1.75) 44.5
(6.42) 163
(5.12) 130 2"
3/4-10UNC- 2B
M20x2.5
(18.93) 481
(2.05) 52
(4.53) 115
(1.42) 36
(0.67) 17
(0.98) 25
660...F... 2.X
(6.3) 160
(5.24) 133
(4.53) 115
(2.36) 60 - - (6.42)
163(5.12) 130
1- 1/2" 1/2-
20UNF- 2B M12x1.75
- (18.54) 471
(2.05) 52
(4.53) 115
(1.42) 36
(0.67) 17 -
660...L... 2.X
(6.3) 160
(5.24) 133
(4.53) 115
(2.36) 60
(3.81) 96.8
(1.75) 44.5
(6.42) 163
(5.12) 130 2"
3/4-10UNC- 2B
M20x2.5
(18.54) 471
(2.05) 52
(4.53) 115
(1.42) 36
(0.67) 17
(0.98) 25
1320...F... 2.X
(6.3) 160
(5.24) 133
(4.53) 115
(2.36) 60 - - (6.42)
163(5.12) 130
1- 1/2" 1/2-
20UNF- 2B M12x1.75
- (29.25) 743
(2.05) 52
(26.38) 670
(1.42) 36
(0.67) 17 -
1320...L... 2.X
(6.3) 160
(5.24) 133
(4.53) 115
(2.36) 60
(3.81) 96.8
(1.75) 44.5
(6.42) 163
(5.12) 130 2"
3/4-10UNC- 2B
M20x2.5
(29.25) 743
(2.05) 52
(26.38) 670
(1.42) 36
(0.67) 17
(0.98) 25
Size 660 1.0 660 2.0 1320 2.0
Weight (lbs.) 70 75.9 112.7
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DF 660-1320
d1
h4Clearance required for element removal
Portd5 x t2IndicatorG 1/2"
G 1/2"Drain Port
5.98
c2
152
c1
h1
4.41112
d2
Inlet
b4
b3 b2
b1
[Mounting Bolts]d4 x t1
4 Places
INLETOUTLET
INLET
G 1/2"Indicator Port
OUTLET
d2 h1
h2
0.24
6
HEX G 1/2" Drain Port
d32 Places
b1
660 1.0 Version 660-1320 2.0 VersionNote - See 1.X Version for mounting
F8
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 330 660 1320Weight (lbs.) 61.5 74.8 112.0
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DF 330/660/1320 3.0 Version
Threaded Port
1-7/8-12UN-2BSAE-24 Port
h1
2.0552
0.24
6
5.87149
HEX1.4236
3.8196.8
1.7544.5
SAE-1.26
32 FlangeCode 62 (2")
[1.06]HEX 27
[0.39]HEX 10Vent PortG1/2"
2.3660
4.53115
M12X22/27
deep0.4010.2
6.42163
5.20132
5.98152
HEX 8 Drain Port G3/8"
6.30160
INLETOUTLET
∆ P CloggingIndicator CavityG 1/2"
h4Clearance required forelement removal
Size h1 h4330...F..3.X [10.35]
263[3.15]
80330...L..3.X660...F..3.x [16.85]
428[9.84] 250660...L..3.x
1320...F..3.x [29.49] 749
[22.44] 5701320...L..3.x
F9
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
00
3
6
9
12
15
0
0.2
0.4
0.6
0.8
1.0
3 6 9 12
0 10 20 30 40
Q (gpm)
DF 30 Housing
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
00
3
15
6
9
12
0
0.2
0.6
0.4
0.8
1.0
5 10 15 20 25 30
0 20 40 60 80 100
Q (gpm)
DF 60/110 Housing
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
00
5
10
15
0
0.2
0.4
0.6
0.8
1.0
20 40 60 80 100
0 50 100 150 200 250 300 350
Q (gpm)
DF 160/240/280 Housing
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
00
5
15
10
0
0.4
0.2
0.6
0.8
1.0
40 80 120 160 200
0 200100 300 400 500 600 700
Q (gpm)
DF 330/660/1320 Housing
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Metal Fiber …D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0030 D XXX V 1.011 0.740 0.411 0.2000060 D XXX V 0.877 0.511 0.296 0.1830110 D XXX V 0.452 0.304 0.182 0.1180160 D XXX V 0.251 0.177 0.123 0.0790240 D XXX V 0.169 0.137 0.093 0.0620280 D XXX V 0.126 0.093 0.064 0.0410330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012
Wire Mesh …D…W/HC ElementsSize 25, 50, 74, 100, 149, 200 µm
0030 D XXX W/HC 0.1660060 D XXX W/HC 0.0420110 D XXX W/HC 0.2300160 D XXX W/HC 0.0160240 D XXX W/HC 0.0100280 D XXX W/HC 0.0090330 D XXX W/HC 0.0080660 D XXX W/HC 0.0041320 D XXX W/HC 0.002
Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0030 D XXX ON 4.27 3.507 2.376 1.251 0.768 0.620060 D XXX ON 2.936 1.427 1.004 0.664 0.537 0.3470110 D XXX ON 1.416 0.735 0.527 0.333 0.254 0.1640160 D XXX ON 1.015 0.604 0.423 0.225 0.204 0.1750240 D XXX ON 0.631 0.379 0.293 0.175 0.134 0.1150280 D XXX ON 0.304 0.185 0.15 0.082 0.075 0.0640330 D XXX ON 0.452 0.23 0.185 0.135 0.085 0.0670660 D XXX ON 0.207 0.106 0.086 0.051 0.039 0.0311320 D XXX ON 0.102 0.053 0.042 0.025 0.019 0.015
Betamicron® ...D...BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0030 D XXX BH4HC 5.005 2.782 1.992 1.0430060 D XXX BH4HC 3.216 1.789 0.993 0.6700110 D XXX BH4HC 1.394 0.818 0.489 0.3070160 D XXX BH4HC 0.922 0.571 0.324 0.2410240 D XXX BH4HC 0.582 0.373 0.214 0.1590280 D XXX BH4HC 0.313 0.187 0.099 0.0880330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022
All Element K Factors in psi / gpm.
F10
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction Gearboxes
Industrial
Pulp & Paper
Offshore
Railways
CommercialMunicipal
Shipbuilding
PowerGeneration
Steel / HeavyIndustry
Features• Available in T ported or L ported configurations• Handles high flows to 250 GPM (pricing competitive)• Available in bidirectional flow and single flow configurations• Two part bowl for ease of operation and element
change-out• Filter head made of ductile iron• Filter housing (bowl) and lid made of steel• Can mount head on top with bottom access (2.x) or head
on bottom with top access (3.x)• Single flow version (DF) can be supplied with bypass
(located in head assembly).• Bidirectional flow version (DFF) can only be supplied with
no-bypass.
DF/DFF 1500 SeriesInline Filters6090 psi • up to 250 gpm
INLET
OUTLET
BypassValve
FilterElement
Pop-upIndicator
DFF FILTERREVERSE FLOW
CIRCUIT
Technical SpecificationsMounting Method 4 Mounting holes
in the filter head - M-12 ThreadsPort Connection SAE-32 four bolt code 62 Flange
(DN 50) with metric bolt threads (M20 x 30mm deep) 2” SAE 32 straight thread O-Ring Boss / 2” BSPP thread
Flow Direction Side inlet and outlet - Indicator on top Side inlet and top outlet - Indicator on side
Construction Materials Head: Ductile Iron (GGG40)Filter housing (bowl) & lid: Steel
Flow Capacity 250 gpm (950 lpm)Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
6090 psi (420 bar)6090 psi (420 bar) @ 300,000 cyclesContact HYDAC
Element Collapse Pressure RatingON, W/HCBH4HC, V
290 psid (20 bar)3045 psid (210 bar)
Fluid Temperature Range 14ºF to 212ºF (-10ºC to 100ºC)Consult HYDAC for applications operating below 14°F (-10°C)
Fluid CompatibilityCompatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected
Indicator Trip Pressure∆P = 29 psid (2 bar) -10%∆P = 72 psid (5 bar) -10%∆P = 116 psid (8 bar) -10% (non-bypass)
Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10%∆P = 87 psid (6 bar) +10%Non Bypass Available
F11
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Clogging Indicator Model CodeVD 5 B . X / V .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 15 psid (1 bar) & 116 psid (8 bar) available upon request
Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch – SPDT D = Electric switch and led light – SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EP = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicators with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with High water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
Replacement Element Model Code 1500 D 010 BH4HC / V Size 1500
Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = BH4HC 25, 74, 149 = W/HC 3, 5, 10, 20 = V
Element Media ON, BH4HC, W/HC, V Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Supplementary Details SO263 = (same as above) SO155H = (same as above) W = Modification of “V” elements for use with oil/water
emulsions (HFA) and water polymer (usually polyglycol) solutions (HFC)
SFREE = (same as above)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Model CodeDF BH/HC 1500 T G 10 B 2 . X / 12 V .
Filter Type DF = Inline filter DFF = Inline filter - Reverse flow
Element Media ON = Optimicron® BH/HC = Betamicron® (High Collapse) (required on DFF) W/HC = Wire Mesh V = Metal Fiber
Size and Nominal Connection 1500 = 2” BSPP / SAE 32 Straight Thread / 2” SAE DN 50 Flange
Pressure T = 6090 psi / 420 bar
Type of Head (omit) = T Port L = L Port
Type of Connection G = 2” Threaded L = 2” Flanged SAE DN 50
Filtration Rating (microns) 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = BH/HC 25, 74, 149 = W/HC 3, 5, 10, 20 = V
Type of ∆P Clogging Indicator A, B, BM, C, D (others available upon request)
Type Number 2 = Standard Mounting - Bottom Accessible (two-piece bowl) 3 = Upside Down Mounting w/o Drain Port in Head (two-piece bowl) - (cust. to supply low point drain external to filter)
Modification Number (latest version always supplied)
Port Configuration (omit) = 2” SAE DN 50 Flange Ports (metric bolt threads M20) 0 = 2” BSPP 12 = 2” SAE Straight Thread O-Ring Boss Ports
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Bypass Valve (omit) = Without Bypass (BH4HC or “V” High Collapse elements recommended)) B3 = 43 psid Bypass (optional)
No bypass on DFF 1500
B6 = 87 psid Bypass (standard)
Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids SO155H = Modification of BH4HC (High Collapse) Element For Phosphate Esters W = “VD…” indicator modified with a brass piston for use with High water based emulsions/solutions
(HFA) & (HFC) or when using “V” elements L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100ºF (C and D indicators only) cRUus = Electrical Indicators with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation
F12
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size DF/DFF 1500 2.0 “L”
Weight (lbs.) 152.8
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DF/DFF 1500 2.0 L Configuration
1766.93
0.24
6 0.9825
2.3660
Mounting Pattern
[27.56] 700Clearance required for element removal
OUTLET
SAE 6000PSIDN 50
INLET
Mounting Surface
122 4.80
6.93
3.8698
6.00
36 HEX
983.86
176
152.4
34.76883
M12x1.75x 22 DP
4.33110
2.1354
1.7544.5
3.81
96.8
5.28134
Drain PortG 1/2"
INLET
3.81 96.8
1.7544.5
M20x2.5x 30 DP
G 1/2"IndicatorPort
F13
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size DF/DFF 1500 3.0 “L”
Weight (lbs.) 152.6
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DF/DFF 1500 3.0 L Configuration
6.93176
SAE 6000PSIDN 50
3.86
34.76883
152.4
6.93
6.00
98 3.86
176
HEX 36
98
4.80122
INLET
Vent PortG 1/2"
OUTLET
4.33110
2.1354
M12x1.75x 22 DP
0.9825
3.81 5.28 134
6 0.24
96.8
1.7544.5
OUTLET
Inlet
96.8
2.363.81 60
1.7544.5
M20x2.5x30 DP
G 1/2"Indicator Port
F14
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Dimensions DF/DFF 1500 2.0 T Configuration
6.93176
Drain PortG1/2"
INLET
44.51.75
3.8196.8
M20x2.5x 30 DP
x 22 DP
134 110
M12x1.75
2.13
1967.72
54
5.284.33
1.06 27
Hex1.0627
Threaded Version
2-1/2"-12UN-2B IN.SAE-32 Port2 Places
[27.56] 700
Mounting Pattern
Clearance requiredfor element removal
G 1/2"
INLET
Indicator Port
OUTLET
6
34.76
4.80
0.24
6.00152.4
36 HEX
2.36
883
60
122
6.93176
Size DF/DFF 1500 2.0 “T”
Weight (lbs.) 152.8
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
F15
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Dimensions DF/DFF 1500 3.0 T Configuration
6.93176
2-1/2"-12UN-2B IN.SAE 32 Port2 Places
G 1/2" Indicator Port
34.29
152.4
124
6.00
871
4.88
60.24
HEX 36
700[27.56]
Clearance requiredfor element removal
Threaded Version
Mounting Pattern
134
5.28
196 7.72
x 23 DPM12x1.75
1104.33
2.1354
HEX1.0627
G1/2"Vent Plug
96.8
6.93
3.81
176
1.7544.5
M20x2.5x 30 DP
INLET OUTLET
Size DF/DFF 1500 3.0 “T”
Weight (lbs.) 152.6
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
F16
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Flow in l/min
Flow in gpm
DF 1500
0 50 100 150 200 250
0 200 400 600 800
0
10
20
30
40
50
Forward
Reverse
0
1.0
0.5
1.5
2.0
2.5
3.0
3.5
Flow in l/min
Flow in gpm
DFF 1500
0
0.4
0.8
1.2
1.6
0 200 400 600 800 1000
0
5
10
15
20
25
0 50 100 150 200 250 300
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors
∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x Actual Viscosity (SUS) x Actual Specific Gravity
(From Tables Below) 141 SUS 0.86
Optimicron …D…ON (Pressure Elements)Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
1500 D XXX ON 0.09 0.053 0.038 0.026 0.02 0.015
Betamicron ...D…BH4HC (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
1500 D XXX BH4HC 0.077 0.044 0.033 0.027
Wire Mesh ...D…W/HC Elements Size ...D…W/HC Elements 25, 50, 74, 100, 149, 200 µm
1500 D XXX W/HC 0.020
Metal Fiber ...D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
1500 D XXX V 0.016 0.011 0.011 0.005
All Element K Factors in psi / gpm.
F17
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Notes
F18
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction Industrial
Railways
Features• DFFX Reverse Flow models filter fluid in the forward direction and
bypass the filter element when the flow direction is reversed.• O-ring seals are used to provide positive, reliable sealing. Choice
of O-ring materials provide compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.
• Screw-in bowl/lid mounted below the filter head requires minimal clearance to remove the element for replacement; contaminated fluid cannot be washed downstream when element is serviced.
• Clogging indicators have no external dynamic seal. This results in high reliability due to magnetic actuation which eliminates a leak point.
• A poppet-type bypass valve (optional) located in the filter head provides positive sealing during normal operation and fast opening during cold starts and flow surges.
DFFX SeriesReverse Flow Differential Pressure Optimized Filters6090 psi • up to 160 gpm
or
DFFX FILTERREVERSE FLOW
CIRCUIT
BY-PASSVALVES
(OPTIONAL)
∆P Indicator
Reverse Flow Valve
OUTLETINLET
Technical SpecificationsMounting Method 4 mounting holesPort ConnectionDFFX 330/660/1320 2” SAE Flange Code 62
Flow Direction Inlet: Side Outlet: Side or TopConstruction MaterialsHeadSingle piece bowl “1.X” BowlTwo piece bowl “2.X” Housing Lid/Cap
Ductile iron
Steel
SteelSteel
Flow Capacity330660/1320
80 gpm (303 lpm)100 gpm (379 lpm)/160 gpm (606 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
6090 psi (420 bar)Contact HYDAC OfficeContact HYDAC Office
Element Collapse Pressure RatingBH4HC, VON, W/HC
3045 psid (210 bar)290 psid (20 bar)
Fluid Temperature Range 14ºF to 212ºF (-10ºC to 100ºC)Consult HYDAC for applications operating below 14°F (-10°C)
Fluid CompatibilityCompatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)∆P = 116 psid (8 bar) -10% (optional)
Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standard)Non Bypass Available
F19
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeDFFX BN/HC 1320 T L L 3 BM 2 . X / 16 V .
Filter Type DFFX = Reverse Flow Bypass Filter
Element Media ON = Optimicron® BH/HC = Betamicron® (High Collapse) W/HC = Wire Mesh V = Metal Fiber
Size and Nominal Connection 330 = 2” Flange SAE Code 62 660 = 2” Flange SAE Code 62 1320 = 2” Flange SAE Code 62
Pressure Range T = 6000 psi (414 bar)
Head Design (omit) = T head L = L Head
Size and Nominal Configuration L = 2” SAE Code 62 Flange)
Filtration Rating (microns) 3, 5, 10, 20 = BH/HC 1, 3, 5, 10, 15, 20 = ON 25, 74, 149 = W/HC 3, 5, 10, 20 = V
Type of ∆P Clogging Indicator A, BM, C, D (others available upon request)
Type Number 1 = One piece bowl (sizes 330-660 only 2 = 2 Piece Bowl (size 660 - 1320) 3 = Upside-down Mounting (size 660 - 1320)
Modification Number (latest version always supplied)
Port Configuration 16 = SAE flange ports
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Bypass Valve (omit) = Non-bypass – Critical applications (high collapse element required) B3 = 43 psid (3 bar) (Optional) B6 = 87 psid (6 bar) (Standard setting for pressure filters)
Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
or when using “V” elements L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100ºF (C and D indicators only) cRUus = Electrical Indicators with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation
Replacement Element Model Code1320 D 003 BH4HC / V .
Size 0330, 0660, 1320
Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = BH4HC 25, 74, 149 = W/HC 3, 5, 10, 20 = V
Element Media BH4HC, ON, W/HC, V
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EP = Ethylene propylene rubber (EPR)
Supplementary Details SO263 = (same as above) SFREE = (same as above)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Clogging Indicator Model CodeVD 8 BM . X / V .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) 8 = 116 psid (8 bar)Type of Indicator A = No indicator, plugged port BM = Pop-up indicator (manual reset) C = Electric switch – SPDT D = Electric switch and LED light – SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EP = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L48 = 48V L110 = 110V L220 = 220V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicators with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F20
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 330 TL1.0v 660 TL1.0vWeight (lbs.) 109.2 124.8
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFFX 330 / 660 TL 1.X Version
0.24
6
3.15
5.13130.2
3.5490
HEX36
1.42
80
0.16
4
Vent PlugG 1/2"
OUTLET
174
75
3.2382
2.95
6.85
1.7745
2 PL'S
for element removal
G 1/2"
Code 62 Flange
Port
Drain Plug
115
[4.53]
Clearance required
INLET
2" SAE
G 1/2" CloggingIndicator
1.75±0.01
346.5
96.8±0.2
2.56
DFFX 330:
149
3.81±0.0182
5.87
3.23
3.94
100
44.5±0.2
2.24
65
57
[20.35]
13.64
DFFX 660: 517
[1.00]3/4"-10UNC-2Bx25.3 DP
7.28185
210
9.02
20
8.27
150
229
6.69
200.79
5.91 170
1/2"-20UNF-2Bx20 DP
0.79
[0.78]
0.16
4
F21
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 330 TLL1.0v 660 TLL1.0vWeight (lbs.) 109.2 124.8
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFFX 330 / 660 TLL 1.X Version
required
Indicator
Port
removal
G1/2" Clogging
for element
[4.53]115Clearance
3.15 80
5.13130.2
HEX
DFFX 330: 346.5
1.4236
DFFX 660:
5.79
20.35517
129 5.08
147
[13.64]
7.28185
OUTLET
G1/2"Drain Plug
6.46
164
2.9575
823.23
0.24
6
2" SAECode 62 Flange 2 PL'SINLET
2.56
229
65
96.8±0.2
1.75±0.01
[1.00]
9.02
3/4"-10UNC-2Bx25.3 DP
3.81±0.01
44.5±0.2
3.2382
8.27
210
200.79
25
0.98
6.10155
[0.79]1/2"-20UNFx20 DP4 PL'S
F22
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 660 TL2.0_3.0v 1320 TL2.0_3.0vWeight (lbs.) 124.8 167.8
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFFX 660 / 1320 TL 2.X & 3.X Version
CloggingG 1/2"
Indicator
Drain plug
port
G1/2"
2" SAE Code 62 Flange2 PL'SINLET
65
100
3.81±0.01
2.56
2.24
44.5±0.2
7.28
96.8±0.2
1.75±0.013.94
185
57
3.23
82
5.87149
[1.00]3/4"-10UNC-2Bx25.3 DP
DFFX 1320: 570 MIN
Vent plug
Drain plugG 1/2"
G1/2"
Clearance requiredfor element removal
[9.84]DFFX 660: 250 MIN [22.44]
5.98152
361.42
20.31DFFX 660:
HEX
DFFX 1320: 838 [32.99]
516
5.87149
AS 2.X VERSION
660-1320 3.XFILTER HEAD SAME
Clearance requiredfor element removal
DFFX 1320: 670 MIN
[13.78]DFFX 660: 350 MIN [26.38]
DFFX 1320: 831
1525.98
[32.72]
3.15
5.20132
20.04
HEX36
509
1.42
0.246
803.54
90
DFFX 660:
1124.41
0.16
4
210 8.27
0.79
0.79
20
5.91 6.69
[0.78]
170
1/2"-20UNF-2Bx20 DP
20
150
9.02229
Vent plugG1/2"
OUTLET
3.23
1.77174
82
6.85
45
2.9575
660 / 1320 2.X Version
F23
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 660 TLL2.0v 1320 TLL2.0vWeight (lbs.) 124.8 167.8
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFFX 660 / 1320 TLL 2.X Version
for element removal
DFFX 1320: 670
G1/2" Clogging
Clearance required
PortIndicator
[13.78]DFFX 660: 350 [26.38]
112
509
4.41
20.04
1475.79
129
DFFX 660:
5.08
5.20
132
7.28185
1.42
[32.72]DFFX 1320: 831
HEX
5.98152
36
3.1580
2" SAECode 62 Flange2 PL'SINLET
1.75±0.01 3/4"-10UNC-2Bx25.3 DP44.5±0.2
65
9.02
2.56
3.81±0.01
229
96.8±0.2
[1.00]
3.2382
OUTLET
G1/2"Drain Plug
1646.46
75
6
2.95
0.24
3.2382
155
0.9825
8.27 210
6.10
0.7920
[0.79]1/2"-20UNFx20 DP4 PL'S
F24
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
DFFX 330 / 660 / 1320 TL Housing
Forward
Reverse
0
20
25
15
10
5
0.0
1.6
1.2
0.8
0.4
0 40 80 120 160 200
0 300200100 400 500 600 700
Flow in gpm
DFFX 330 / 660 / 1320 TLL Housing
Forward
Reverse
0
20
25
15
10
5
0.0
1.6
1.2
0.8
0.4
0 40 80 120 160 200
0 300200100 400 500 600 700
Flow in gpm
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Metal Fiber …D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012
Wire Mesh …D…W/HC ElementsSize 25, 50, 74, 100, 149, 200 µm
0330 D XXX W/HC 0.0080660 D XXX W/HC 0.0041320 D XXX W/HC 0.002
Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0330 D XXX ON 0.452 0.23 0.185 0.135 0.085 0.0670660 D XXX ON 0.207 0.106 0.086 0.051 0.039 0.0311320 D XXX ON 0.102 0.053 0.042 0.025 0.019 0.015
Betamicron ...D...BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022
All Element K Factors in psi / gpm.
F25
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Notes
F26
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction Gearboxes
Industrial
Pulp & Paper
Offshore
Railways
CommercialMunicipal
Shipbuilding
PowerGeneration
Steel / HeavyIndustry
Features• Non-welded housing design reduces stress concentrations and
prevents fatigue failure.• Choice of SAE straight thread O-ring boss, and straight thread
BSPP (sizes 300 - 900) to allow easy installation without costly adapters.
• O-ring seals are used to provide positive, reliable sealing. We offer a choice of O-ring materials (Nitrile rubber or Fluorocarbon elastomer), to provide compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.
• Screw-in bowl mounted below the filter head requires minimal clearance to remove the element for replacement and contaminated fluid cannot be washed downstream when element is serviced.
• HYDAC Differential Pressure Indicators have no external dynamic seal. This results in a high system reliability due to magnetic actuation, thus eliminating a potential leak point.
• A poppet-type bypass valve (optional) provides positive sealing during normal operation and fast opening during cold starts and flow surges.
• The HDF is available with a bypass valve. The HDFF is offered in non bypass only.
• Fatigue pressure ratings equal maximum allowable working pressure rating.
• Inlet/outlet ports in “L” configuration • No element valve-only available with HDF in “L” configuration.
HDF/HDFF SeriesInline Filters & Inline Filters With Reversible Flow4060 psi • up to 100 gpm
Technical SpecificationsMounting Method 4 mounting holesPort Connection 300, 450, 650, 900: 1” SAE-16 parallel straight thread or
1” BSPP or1 1/4” SAE-20 parallel straight thread or 1 1/4” BSPP or1 1/2” SAE-24 parallel straight thread or 1 1/2” BSPP
Flow Direction Inlet: Side Outlet: Top Construction Materials Head Bowl
Ductile ironSteel
Flow Capacity 300 450 650 900
30 gpm (114 lpm)60 gpm (227 lpm)90 gpm (340 lpm)100 gpm (378.5 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue Pressure
4060 psi (280 bar)4060 psi (280 bar) @ 1 million cycles6090 psi (420 bar) @ 250,000 cycles
Burst Pressure (Consult HYDAC)
Element Collapse Pressure RatingBH4HC ON
3045 psid (210 bar)290 psid (20 bar)
Fluid Temp. Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.Indicator Trip Pressure��∆P = 29 psid (2 bar) -10% (optional)��∆P = 72 psid (5 bar) -10% (standard)��∆P = 116 psid (8 bar) -10% (optional non bypass)
Bypass Valve Cracking Pressure��∆P = 43 psid (3 bar) +10% (optional-HDF only)��∆P = 87 psid (6 bar) +10% (standard) Non Bypass Available for HDF (HDFF available only with no bypass)
A
B
A
B
F27
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeHDF BH/HC 450 O L E 10 D 1 . X / 12 V .
Filter Type HDF or HDFF (HDFF on request)
Element Media ON = Optimicron® BH/HC = Betamicron® (High Collapse) Size 300, 450, 650, 900
Pressure Range O = 4060 psi (280 bar); 6090 psi (420 bar) at 250,000 cycles
Type of Connection L = Flow path in L-configuration (standard version)
Size and Nominal Connection D = 1” Threaded E = 1 1/4” Threaded F = 1 1/2” Threaded
Filtration Rating (microns) 3, 5, 10, 20 = BH/HC 1, 3, 5, 10, 15, 20 = ON
Type of ∆P Clogging Indicator A, BM, C, D, Y
Type Modification Number 1
Modification Number (latest version always supplied)
Port Configuration 0 = BSPP straight thread 12 = SAE parallel straight thread o-ring boss ports
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Bypass Valve (omit) = Non-bypass - critical applications (high collapse element required) B3 = 43 psid (3 bar) - optional B6 = 87 psid (6 bar - standard setting for pressure filters)
Supplementary Details L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) LED = 2 light-emitting diodes up to 24 Volt (only for clogging indicator type “D”) NEV = No Element valve (only for HDF filters in L-configuration) SO184 = pressure release drain screw (G-1/2”) SFREE = Element specially designed to minimize electrostatic charge generation W = “VD…” indicator modified with a brass piston for use with high water based
emulsions/solutions (HFA) & (HFC) or when using “V” elements
Replacement Element Model Code0450 D 010 BH4HC / V .
Size 0300, 0450, 0650, 0900
Type D
Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 1, 3, 5, 10, 15, 20 = ON
Element Media BH4HC, ON
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) Supplementary Details W = (same as above) SFREE = (same as above)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Clogging Indicator Model CodeVD 8 D . X / V .
Indicator Prefix VD = differential pressure
indicator up to 420 bar operating pressure
Pressure setting 5 = standard 5 bar (for HDF filters) 8 = standard 8 bar (for HDFF filters) Others available upon request
Type of Indicator A = No indicator, plugged port BM = Pop-up indicator (manual reset) C = Electric switch – SPDT D = Electric switch and LED light – SPDT Y = Plastic blanking plug in indicator port
Modification Number (latest version always supplied)
Supplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) Light Voltage (D type indicators only) L24 = 24V L110 = 110V
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F28
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 300 450 650 900
Weight (lbs.) 24.7 28.9 35.8 47.4
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions HDF/HDFF 300-900
d3 t1
d3
G 1/2"Indicator Port ∆ P Clogging
Drain Port (Optional)G 1/2" -(SO184)
h1
1.26
4.14
32
105.2
57
HEX
t1 INLET Port
OUTLETPort
632.48
88.95.16
131.1
2.8372
42.9
2
3.50
1.69
Mounting Holesd4 x t2
4 Places
HDF/HDFF h1
300 [9.680]246
450 [13.35]339
650 [18.11]460
900 [22.28]566
ød3 †1 ød4 †2
G1 [0.71]18
M10 X 1.5 [0.71]18G1-1/4 [0.79]
20
G1-1/2 [0.87]22
SAE-16 [0.75]19
3/8-24UNF-2B [0.55]14SAE-20 [0.75]
19
SAE-24 [0.75]19
F29
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
00
1
2
3
5
4
7
6
10
9
8
0
0.2
0.4
0.6
0.1
0.3
0.5
10 3020 50 6040 70 9080 100
0 50 100 150 200 250 300 350
Q (gpm)
HDF Housing
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
00
5
10
30
15
20
25
0
0.5
1.0
1.5
2.0
10 20 4030 50 60 70 80 90 100
15050 1000 200 250 300 350
Q (gpm)
HDFF Housing
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors
∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x Actual Viscosity (SUS) x Actual Specific Gravity
(From Tables Below) 141 SUS 0.86
Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0300 D XXX ON 0.801 0.488 0.391 0.268 0.154 0.1430450 D XXX ON 0.401 0.244 0.193 0.131 0.077 0.0690650 D XXX ON 0.245 0.148 0.121 0.081 0.047 0.0440900 D XXX ON 0.185 0.115 0.092 0.06 0.036 0.035
Betamicron ...D…BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0300 D XXX BH4HC 0.878 0.488 0.390 0.1810450 D XXX BH4HC 0.428 0.236 0.187 0.0880650 D XXX BH4HC 0.258 0.143 0.115 0.0550900 D XXX BH4HC 0.192 0.110 0.088 0.038
All Element K Factors in psi / gpm.
F30
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction Industrial
Railways
Features• Non-welded housing design reduces stress concentrations and
prevents fatigue failure.• Inlet/Outlet port options include SAE straight thread O-ring boss,
BSPP and subplate mounting to allow easy installation without costly adapters.
• O-ring seals are used to provide positive, reliable sealing. A choice of O-ring materials (nitrile, fluorocarbon elastomer, ethylene propylene rubber) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.
• Screw-in bowl mounted below the filter head requires minimal clearance to remove the element for replacement and contaminated fluid cannot be washed downstream when element is serviced.
• Clogging indicators are actuated by differential pressure and have no external dynamic seal. High reliability is achieved and magnetic indicator actuation eliminates a potential leak point.
• A poppet type bypass valve is typically mounted in the filter head out of the flow path between the inlet and outlet port to provide positive sealing during normal operation and fast response during cold starts and flow surges.
• Fatigue pressure rating equals maximum allowable working pressure rating.
HF2P SeriesInline Filters4000 psi • up to 25 gpm
A
B
Technical SpecificationsMounting Method 2 mounting holesPort Connection SAE-12, 3/4” BSPP,
Manifold Mount – (0.689”)Flow Direction Inlet: Side Outlet: SideConstruction MaterialsHeadBowl
Ductile ironSteel
Flow Capacity4”8”
16 gpm (60 lpm)25 gpm (95 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
4000 psi (276 bar)4000 psi (276 bar) @ 1 million cycles14,680 psi (1012 bar)
Element Collapse Pressure RatingBH4HCBN
3045 psid (210 bar)290 psid (20 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)∆P = 116 psid (8 bar) -10% (optional on bypass)
Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standard)Non Bypass Available
F31
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeHF2P BN 08 G 3 C 1 . 2 / 12 V - B6 - T100
Filter Type HF2P = Inline pressure filter
Element Media BN = Betamicron® (Low Collapse) BH = Betamicron® (High Collapse)
Element Length 04 = 4 inches 08 = 8 inches
Type of Connection G = Threaded In-Line P = Manifold Mount
Filtration Rating (microns) 3, 6, 12, 25 = BN 3, 6, 10, 17 = BH
Type of Clogging Indicator A, B, BM, C, D, J, J4 (others available upon request)
Type Code 1
Modification Number (the latest version is always supplied)
Port Configuration (omit) = Manifold Filter 12 = SAE 12” straight thread O-ring boss 0 = BSPP straight thread G 3/4” (contact factory for minimum quantity & availability)
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Bypass Valve (omit) = Non-bypass - Critical applications (high collapse element required) B3 = 43 psid (3 bar) - Optional B6 = 87 psid (6 bar) (standard)
Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Thermal lockout on indicator at 100ºF (C, D, J, and J4 indicators only) cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Replacement Element Model Code 1 . 07 . 08 D 03 BN / V Length (nominal inches) 04, 08Filtration Rating (micron) 3, 6, 12, 25 = BN 3, 6, 10, 17 = BHElement Media BN, BHSeals (omit) = Nitrile rubber (NBR) (standard)
V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Supplementary Details SO263 = (same as above) SFREE = (same as above)
Clogging Indicator Model CodeVD 5 C . X / V .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 116 psid (8 bar) available upon request
Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) (Top mount only) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT J = Electric switch (Brad Harrison 5-pin mini connector) J4 = Electric switch - M12
(Brad Harrison 4-pin micro connector)
Modification NumberSupplementary Details Seals (omit) = Nitrile RUBBER (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F32
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 04 08
Weight (lbs.) 10.7 14.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
3.3986
HEX [0.95]
24
∆P Clogging Indicator Port G 1/2
2.0552
0.8421.4
Clearance requiredfor element removal
75
OUTLETINLET
[2.96]
Mounting Holes [0.27]
6.75Thru2 Places
79.4
4.02
3.86
3.00
3.13
76.2
98
1.00 25.4
[8.43]HF2P-04 214
[12.09]HF2P-08 307
102
0.24
6
Dimensions HF2P Inline Mounting
F33
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 04 08
Weight (lbs.) 10.7 14.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
∆P Cloggingindicator portG 1/2
96
HF2P-04 212 [8.34]
104 4.09
3.78
763.00
HF2P-08 305 [12.01]
1.0226
OUTLETINLET
HEX [0.95]
24
3.4186.5
31.81.25
17
0.63
15.9
0.28
0.689
8.6
7
0.67
(4 Places)
3.50 88.9
17.50.689
17.5
1.25 31.8
0.34
Mounting Holes
1.4637
Dimensions HF2P Subplate Mounting
F34
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
141210
8642
1.2
0.8
0.4
0.00 5 10 15 20 25
0 20 40 60 80 100
Q in gpm
Q in l/min
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Autospec HF2 Depth 1.07.08DXXBN (Low Collapse)Size 3 µm 6 µm 12 µm 25µm
1.07.04DXXBN 2.046 1.735 0.925 0.5311.07.08DXXBN 0.975 0.815 0.457 0.257
Autospec HF2 Depth 1.07.08DXXBH (High Collapse)Size 3 µm 6 µm 10 µm 17 µm
1.07.04DXXBH 2.400 1.690 1.027 0.5381.07.08DXXBH 1.165 0.820 0.499 0.262
All Element K Factors in psi / gpm.
F35
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Notes
F36
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Applications
Automotive Construction Industrial Railways
Steel / HeavyIndustry
Features• Non-welded housing design reduces stress concentrations and
prevents fatigue failure.• Inlet/Outlet port options include SAE straight thread O-ring boss,
BSPP and flange mounting to allow easy installation without costly adapters.
• O-ring seals are used to provide positive, reliable sealing. Choice of O-ring materials (nitrile rubber, fluorocarbon elastomer, ethylene propylene rubber) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.
• Screw-in bowl or lid (on 2 piece bowls), mounted below the filter head requires minimal clearance to remove the element for replacement, and contaminated fluid cannot be washed downstream when element is serviced.
• Clogging indicators are actuated by differential pressure and have no external dynamic seal. High reliability is achieved and magnetic indicator actuation eliminates a potential leak point.
• A poppet type bypass valve, located in filter head, mounted between the inlet and outlet port to provides positive sealing during normal operation and fast response during cold starts and flow surges, while additionally providing low operating ∆P.
• Fatigue pressure rating equals maximum allowable working pressure rating.
HF3P SeriesInline Filters6090 psi • up to 120 gpm Hydraulic Symbol
A
B
Technical SpecificationsMounting Method 4 mounting holesPort Connection SAE-16, SAE-24, 1” BSPP,
1 1/2” BSPP, 1 1/2” SAE Flange Code 61, 2” SAE Flange Code 62
Flow Direction Inlet: Side Outlet: SideConstruction MaterialsHeadBowlHousing (size 16)Cap (size 16)
Ductile ironSteelSteelDuctile iron
Flow Capacity4”8”13”16”
28 gpm (106 lpm)55 gpm (208 lpm)91 gpm (344 lpm)120 gpm (454 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
6090 psi (420 bar)6090 psi (420 bar) @ 1 million cycles 15,080 psi (1040 bar)
Element Collapse Pressure RatingBHBN
3045 psid (210 bar)290 psid (20 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)∆P = 116 psid (8 bar) -10% (optional)
Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standardNon Bypass Available
F37
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeHF3P BN 08 G 3 B 1.2 / 12 V B7 .
Filter Type HF3P = In-Line pressure filter
Element Media BN = Betamicron® (Low Collapse) BH = Betamicron® (High Collapse)
Element Length 04 = 4 inches (non-standard) 13 = 13 inches 08 = 8 inches 16 = 16 inches (non-standard)
Type of Connection G = Threaded Inline F = Flanged Inline
Filtration Ratings (microns) 3, 6, 12, 25 = BN 3, 6, 10, 17 = BH
Type of ∆P Clogging Indicator A, B, BM, C, D, J, J4
Type Modification Number 1.2 = 2” Flange code 62 or SAE 24” or G 1 1/2 2.1 = 1 1/2” Flange code 61 (this will lower MAWP to 3000 psi (206.8 bar)) 3.1 = 1” SAE 16 or G 1” Threaded (reduced port)
Port Configuration 0 = BSPP Threaded Ports G 1 1/2” or G 1” 12 = SAE straight thread O-ring boss SAE 24” or SAE 16” 16 = SAE flange ports - SAE 2”, code 62 (6000 psi) or 1 1/2” code 61
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Bypass Valve (omit) = without bypass (BH elements recommended) B3 = 3 bar/43 psid B6 = 6 bar/87 psid (standard)
Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Thermal lockout on indicator at 100°F (C, D, J, and J4 indicators only) cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Replacement Element Model Code 1 . 11 . 08 D 03 BN / V Length (nominal inches) 04, 08, 13, 16Filtration Rating (micron) 3, 6, 12, 25 = BN 3, 6, 10, 17 = BHElement Media BN, BHSeals (omit) = Nitrile rubber (NBR) (standard)
V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Supplementary Details SO263 = (same as above) SFREE = (same as above)
Clogging Indicator Model CodeVD 5 C . X / V .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 116 psid (8 bar) available upon request
Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT J = Electric switch (Brad Harrison 5-pin mini connector) J4 = Electric switch - M12 (Brad Harrison 4-pin micro connector)
Modification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Clogging Indicators section.)
F38
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 04 08 13 16
Weight (lbs.) 49.2 56.1 72.5 107.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions HF3P-04/08/13/16
6.42163
6.30160
c x d DP4 Places
b
a
6.42163
1/2"-20UNF x [0.67]
174 Places 60
2.36
5.23133
4.53115
Drain PortG 1/2"
[4.53] 115Clearance requiredfor element removal
[16.81] 427Clearance required forelementremoval
Flange
Drain PortG 1/2"
∆P Clogging IndicatorPort G 1/2"
56922.40
112
HF3P-16
HEX
1305.12
1.42
36
1525.98
4.41
6.30160
InletOutlet
∆P Clogging IndicatorPort G 1/2"
1.4236
2.05
0.2452
18.98
482.1 HF3P-13
6
[10.00] HF3P-04 254
[74.00]HF3P-08 349
HEX
5.12130
a b c d
1-1/2” Code 61
(1.406) 35.71
(2.750) 69.85
1/2-13UNC-2B (0.87) 22
2” Code 62
(1.750) 44.45
(3.812) 96.80
3/4-10UNC-2B (0.98) 25
HF3P-16
F39
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Autospec HF3 Depth 1.11.08DXXBN (Low Collapse)Size 3 µm 6 µm 12 µm 25 µm
1.11.04DXXBN 0.590 0.500 0.266 0.1531.11.08DXXBN 0.289 0.241 0.135 0.0761.11.13DXXBN 0.175 0.146 0.082 0.0461.11.16DXXBN 0.132 0.110 0.062 0.035
Autospec HF3 Depth 1.11.08DXXBH (High Collapse)Size 3 µm 6 µm 10 µm 17 µm
1.11.04DXXBH 0.937 0.660 0.401 0.2101.11.08DXXBH 0.460 0.321 0.195 0.1021.11.13DXXBH 0.274 0.193 0.117 0.6151.11.16DXXBH 0.206 0.145 0.089 0.046
All Element K Factors in psi / gpm.
F40
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Automotive Construction Industrial
Pulp & Paper Railways
PowerGeneration
Steel / HeavyIndustry
Features• Meets HF4 automotive standard• Non-welded housing design reduces stress concentrations and
prevents fatigue failure.• Inlet/Outlet port options include SAE straight thread O-ring boss,
SAE flange code 62 and code 61 (optional) BSPP and subplate mounting to allow easy installation without costly adapters.
• O-ring seals are used to provide positive, reliable sealing. A choice of O-ring materials (nitrile rubber or fluorocarbon elastomer) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.
• The element filter housing is permanently mounted above the filter head for easy top access and minimal clearance to remove elements for replacement.
• Clogging indicators are actuated by differential pressure and have no external dynamic seal. High reliability is achieved and magnetic indicator actuation eliminates a potential leak point.
• A poppet type bypass valve located in filter head base is mounted between the inlet and outlet port to provide positive sealing during normal operation and fast response during cold starts and flow surges.
• Fatigue pressure rating equals maximum allowable working pressure rating.
HF4P SeriesInline Filters5000 psi • up to 120 gpm
A
B
Technical SpecificationsMounting Method 4 mounting holesPort Connection SAE-24, 1 1/2” BSPP, 1 1/2” SAE
Flange Code 61, 1 1/2” SAE Flange Code 62, Manifold Mount
Flow Direction Inlet: Side Outlet: Side(opposite each other)
Construction MaterialsHead, CapHousing
Ductile ironSteel
Flow Capacity9”18”27”
50 gpm (189 lpm)100 gpm (378 lpm)120 gpm (454 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
5000 psi (345 bar)5000 psi (345 bar) @ 1 million cycles15,000 psi (1040 bar)
Element Collapse Pressure RatingBHBN
3045 psid (210 bar)145 psid (10 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)∆P = 116 psid (8 bar) -10% (optional on non-bypass filters)
Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standard)Non Bypass Available
F41
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeHF4P BN 09 G 3 D 1 . 1 / 12 V B6 L115
Filter Type HF4P = Inline pressure filter
Element Media BH = Betamicon® (High Collapse) BN = Betamicron® (Low Collapse) W = Wire Mesh
Element Length 09 = 9 inches 18 = 18 inches 27 = 27 inches
Type of Connection P = Manifold Mount G = Threaded In-Line F = Flanged
Filtration Rating (microns) 3, 5, 10, 20 = BH, BN 25, 74, 149 = W
Type of Clogging Indicator A, BM, C, D, J, J4 (others available upon request)
Type Code 1
Modification Number (the latest version is always supplied)
Port Configuration (omit) = Manifold mount (use when “P” connection type is selected) 0 = 1 1/2” BSPP Straight Threads 12 = SAE-24 straight thread O-ring boss 16 = 1 1/2” SAE 4 bolt flange code 61 or 62
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Bypass Valve (omit) = Non-bypass – Critical applications (high collapse element required) B3 = 43 psid (3 bar) B6 = 87 psid (6 bar) Standard setting for pressure filters
Supplementary Details W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Thermal lockout on indicator at 100°F (C, D, J, and J4 indicators only) Code 61 = 4 Bolt Code 61 (changes MAWP from 5000 PSI to 3000 PSI) cRUus = Electrical Indicator with underwriter’s recognition
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Replacement Element Model Code5 . 03 . 09 D 03 BN / V
Length (nominal inches) 09, 18, 27Filtration Rating (micron) 3, 5, 10, 20 = BN, BH 25, 74, 149, = WElement Media BN, BH, WSeals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Clogging Indicator Model CodeVD 5 D . X / V .
Indicator Prefix VD = G 1/2 6000 psi
Trip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 15 psid (1 bar) & 116 psid (8 bar) available upon request
Type of Indicator A = No indicator, plugged port BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT J = Electric switch (Brad Harrison 5-pin mini connector) J4 = Electric switch - M12
(Brad Harrison 4-pin micro connector)
Modification Number
Supplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Light Voltage (D type indicators only) L24 = 24V L48 = 48V L110 = 110V L220 = 220V
Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F
Underwriters Approval (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicators with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F42
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 09 18 27
Weight (lbs.) 69.9 98.4 132.8
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
38.1
a
b
HF4P-09
[12.00]305
HF4P-18 [21.00]533
HF4P-27 [30.00]762
Clearance requiredfor element removal
c x d DPSAE Flange
INLET1-1/2" Nominal Port2 Places
HF4P-09[16.33]
415HF4P-18[25.62]
651HF4P-27[35.00]
889
0.8822.4
P Cloggingindicator portG 1/2"
∆
Vent PlugSAE-4(7/16-20UNF)
1596.25
1.3835
2.7569.9
Drain PlugSAE 8(3/4"-16UNF)
133.45.25
5.75146
4.50
1275.00
114.3
14Mounting
holes Through4 Places
Dimensions HF4P Inline
Flange Details a b c d
Code 61
(1.406) 35.7
(2.750) 69.8
1/2-13UNC (1.06) 27
Code 62
(1.437) 36.50
(3.125) 79.38
5/8-11UNC (1.38) 35
F43
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 09 18 27
Weight (lbs.) 71.7 100.2 134.6
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Drain PlugSAE 8(3/4"-16UNF)
Vent PlugSAE 4(7/16"-20UNF)
15 159
22 0.88
0.586.25
1.3835
2.7569.9
OUTLET[1.25]
32
INLET[1.25]
32127 5.00
2.0050.8
Mounting
4 Places
14
0.56
2.2557.2
holes Through
114.3 4.50
0.8120.6
∆P CloggingIndicator PortG 1/2"
133.45.25
5.75146 HF4P-09
[12.00]305
HF4P-18 [21.00]533
HF4P-27 [30.00]762
Clearance requiredfor element removal
HF4P-09[16.30]
414HF4P-18[25.59]
650HF4P-27[34.98]
888
Dimensions HF4P Manifold
F44
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Autospec HF4 Wire Mesh 5.03.XXDXXWSize 25, 74, 149, µm
5.03.09DXXW 0.0075.03.18DXXW 0.0045.03.27DXXW 0.002
Autospec HF4 Depth 5.03.XXDXXBN (Low Collapse)Size 3 µm 5 µm 10 µm 20 µm
5.03.09DXXBN 0.168 0.141 0.079 0.0445.03.18DXXBN 0.080 0.067 0.038 0.0215.03.27DXXBN 0.052 0.043 0.024 0.014
Autospec HF4 Depth 5.03.XXDXXBH (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
5.03.09DXXBH 0.207 0.146 0.089 0.0475.03.18DXXBH 0.097 0.068 0.041 0.0225.03.27DXXBH 0.063 0.044 0.027 0.014
All Element K Factors in psi / gpm.
F45
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Notes
F46
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction Gearboxes
Industrial CommercialMunicipal
Features• Because of their efficient design and construction, MFM filters
are considered a cost effective solution for new equipment, or as a replacement for filters already specified on existing equipment.
• The MFM filter is available in 4 sizes comprised of four different bowl and element lengths. The models 35, 55, 75, and 95, provide maximum flow rates of 10, 18, 20, and 25 GPM respectively.
• A quick-response bypass valve located in filter head protects against high differential pressures caused by cold startups, flow surges and pressure spikes.
• The high bypass pressure setting (100 psid) minimizes the possibility of contamination due to premature bypassing.
• Filter materials are compatible with all mineral, lubricating oils, and commonly used fire retardant fluids per ISO 2943.
• Fatigue pressure rating equals maximum allowable working pressure rating.
MFM SeriesInline Filters4060 PSI • up to 25 GPM
A
B
Technical SpecificationsMounting Method 4 mounting holes - filter headPort Connection SAE-12, 3/4” BSPPFlow Direction Inlet: Side
(opposite each other)Outlet: Side
Construction MaterialsHeadBowl
Ductile ironSteel
Flow Capacity35557595
10 gpm (35 lpm)18 gpm (68 lpm)20 gpm (76 lpm)25 gpm (95 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue Pressure
Burst Pressure
4060 psi (280 bar)4060 psi (280 bar) @ 1 million cycles4641 psi (320 bar) @ 100,000 cycles13,920 psi (960 bar)
Element Collapse Pressure RatingON 290 psid (20 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 72 psid (5 bar) -10%Bypass Valve Cracking Pressure∆P = 50.75 psid (3.5 bar) +10% (optional)∆P = 100 psid (7 bar) +10% (standard)
F47
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeMFM ON 35 O I 10 C 4 . 0 / V B7 .
Filter Type MFM = In-Line High Pressure Filter
Element Media ON = Optimicron® (Low Collapse)
Size 35 = 10 gpm 55 = 18 gpm 75 = 20 gpm 95 = 25 gpm
Operating Pressure O = 4000 psi (280 bar)
Type of Connection I = 3/4” Threaded SAE 12 (1-1/16-12UN-2B)) H = 3/4” Threaded G 3/4 (BSPP) (Other connections available on request)
Filtration Rating (microns) 1, 3, 5, 10, 15, 20 = ON
Type of Clogging Indicator A, B, BM, C, D (Others available upon request)
Type Number 4 = Indicator port on top of head - 4 mounting holes (standard) 3 = Indicator port on side of head - 3 mounting holes
Type Modification Number (latest version always supplied)
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Bypass Valve B3.5 = 50.75 psid (3.5 bar) - Optional B7 = 101.5 psid (7 bar) - Standard
Supplementary Details W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) LED = 2 LEDs up to a voltage of 24 Volt T100 = Indicator Thermal Lockout, 100°F (C and D indicators only) SFREE = Element specially designed to minimize electrostatic charge generation cRUus = Electrical Indicator with underwriter’s recognition
Replacement Element Model Code 0035 D 010 ON / V Size 0035, 0055, 0075, 0095
Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = ON
Element Media ON = Optimicron®
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) Supplementary Details SFREE = (same as above)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Clogging Indicator Model CodeVD 5 C . X / V .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard)
Type of Indicator A = no indicator, plugged port B = Pop-up indicator (auto reset)
- top mount only BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F48
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 35 55 75 95
Weight (lbs.) 8.2 9.3 10.4 11.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
3.5490
1.3835
Mounting Holes3/8-16 UNC-2B x 12 DP4 Places
2.17 55
1.5740
1.0125.7
∆ P Clogging Indicator PortG 1/2HEX 27
INLET
OUTLET
for Element RemovalClearance Required 74[2.91]
86
3.00
3.39
76.2
HEX 0.9424
Size 95 297
259
60.24
3.62
Size 75 [11.77]
92
10.20
[6.30]Size 35 160
[8.11]Size 55 206
3.5490
Dimensions MFM 4.X Version (Standard)
F49
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 35 55 75 95
Weight (lbs.) 8.2 9.3 10.4 11.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
1.3835
3.5490
74
Clearance Requiredfor Element Removal
[2.91]
10.20259
[11.77]Size 95 297
903.54
[6.30] Size 35 160
[8.11] Size 55 206
Size 75
3.6292
0.9424
76.2
HEX
3.00
3.3986
∆P Clogging Indicator Port G1/2HEX 27
INLETOUTLET
1.26
3/8-16UNC-2B
55°
3 Places
32
Mounting Holes
56 2.20
23.50.93
1.7745
Dimensions MFM 3.X Version
F50
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Q in gpm
0.0
5.0
10.0
15.0
20.0
25.0
0 3 5 8 11 13 16 18 21 24 260.00
0.34
0.69
1.03
1.38
1.720 10 20 30 40 50 60 70 80 90 100
Q in l/min
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Optimicron …D…ON (Pressure Elements)Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0035 D XXX ON 2.755 1.169 0.938 0.752 0.549 0.4080055 D XXX ON 1.427 0.675 0.543 0.434 0.284 0.2110075 D XXX ON 0.916 0.461 0.37 0.296 0.183 0.1360095 D XXX ON 0.724 0.37 0.296 0.238 0.144 0.105
All Element K Factors in psi / gpm.
F51
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Notes
F52
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction Gearboxes
Industrial CommercialMunicipal
PowerGeneration
Features• The HFM filter is available in two sizes comprised of two different
bowl and element lengths. The models 75 and 95 provide maximum flow rates of 29 and 37 GPM respectively.
• A quick-response by-pass valve located in the filter head, protects against high differential pressures caused by cold start-ups, flow surges and pressure spikes.
• The high bypass pressure setting (100 psid) minimizes the possibility of contamination due to premature bypassing.
• Filter materials are compatible with all mineral, lubricating oils, and commonly used fire retardant fluids per ISO 2943.
• Fatigue pressure rating equals maximum allowable working pressure rating.
• Wide variety of indicators available with standard setting of 72 psid (5 bar).
HFM SeriesInline Filters5800 psi • up to 37 gpm
A
B
Technical SpecificationsMounting Method 3 or 4 mounting holes - filter headPort Connection SAE 16, 1” BSPPFlow Direction Inlet: Side
(opposite each other)Outlet: Side
Construction MaterialsHeadBowl
Ductile ironSteel
Flow Capacity7595
29 gpm (110 lpm)37 gpm (140 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
5800 psi (400 bar)Contact HYDAC office13,920 psi (960 bar)
Element Collapse Pressure RatingON 290 psid (20 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications below 14˚F (-10˚C)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 72 psid (5 bar) -10% (standard)
Bypass Valve Cracking Pressure∆P = 101.5 psid (7 bar) +10% (standard)
F53
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model Code HFM ON 95 S K 10 A 1 . 0 / V B7 Filter Type HFM = In-Line High Pressure Filter
Element Media ON = Optimicron® (Low Collapse)
Size 75 = 29 gpm 95 = 37 gpm
Operating Pressure S = 5800 psi (400 bar)
Type of Connection J = 1” threaded (1” BSPP) K = 1” threaded (1 5/16” threaded-12UN)=SAE 16
Filtration Rating (microns) 1, 3, 5, 10, 15, 20 = ON
Type of Clogging Indicator A, B, BM, C, D (Others available upon request)
Type Number 1
Type Modification Number (latest version always supplied)
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Bypass Valve B3.5 = 50.75 psid (3.5 bar) (optional) B7 = 101.5 psid (7 bar) (standard)
Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) LED = 2 LEDs up to a voltage of 24 Volt T100 = Thermal lockout on indicator at 100°F (C and D indicators only) SFREE = Element specially designed to minimize electrostatic charge generation cRUus = Electrical Indicator with underwriter’s recognition
Replacement Element Model Code 0095 D 010 ON / V Size 0075, 0095
Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = BN4HC
Element Media ON = Optimicron®
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Supplementary Details SO263 = (same as above) SFREE = (same as above)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Clogging Indicator Model CodeVD 5 B . X / V .
Indicator Prefix VD = G 1/2 6000 psi
Trip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 15 psid (1 bar) & 116 psid (8 bar) available upon request
Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT
Modification Number
Supplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Light Voltage (D type indicators only) L24 = 24V L110 = 110V
Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F
Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F54
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 75 95
Weight (lbs.) 12.4 13.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions HFM 75/95
1.3835
3.8698
SAE mounting Pattern BSPP Mounting Pattern
75Clearance requiredfor element removal
[2.95]
∆P CloggingIndicator PortG 1/2HEX 27
4.21 107
HFM 95 311
10.67271HFM 75
[12.24]
0.24
6 Inlet
3.0076.2
HEX 0.9424
OUTLET
4 Places
[0.33]5/16-24UNF-2B x 8.5 DPMounting holes
INLET
1.1028
104 4.09
321.26
51
2.01
2.2056
OUTLET
4 Places
3 PlacesMounting holesM8 x 1.25 x 12 DP [0.47]
[0.43]M6 x 1.0 x 11 DPMounting Holes
INLET
2.20
56 56
2.20
190.75
32 1.26
0.35
9
F55
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Q in gpm
Q in l/min
0.0
1.4
2.9
4.3
5.8
7.2
8.7
10.1
0 5.3 10.6 15.8 21.1 26.4 31.7 37.00.0
0.1
0.2
0.3
0.4
0.5
0.6
0.70 20 40 60 80 100 120 140
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Optimicron …D…ON (Pressure Elements)Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0075 D XXX ON 0.916 0.461 0.37 0.296 0.183 0.1360095 D XXX ON 0.724 0.37 0.296 0.238 0.144 0.105
All Element K Factors in psi / gpm.
F56
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction Industrial
Railways PowerGeneration
Steel / HeavyIndustry
Features• The FMND filter consists of a ductile iron filter head with built-in
changeover valve and three different lengths of screw-in filter bowls.
• The FMND filter can be supplied with or without bypass valve, (located in head assembly) but includes vent and drain screws, and also a connection for a differential pressure clogging indicator.
• Pressure equalization requirement is achieved by raising the changeover lever prior to switching it to the relevant filter side.
• Fatigue pressure rating = maximum allowable working pressure rating.
• Germanischer Lloyd (GL) approved• This filter meets the requirements of DIN 24550 as follows:
- Filter size 0160 with G 1-1/4” port selection - Filter size 0250 with G 1-1/2” port selection - Filter size 0400 with SAE-DN 38 1-1/2” Flange Port Selection
FMND SeriesInline Duplex Filters3000 psi • up to 100 gpm
VA
OUTLET
INLET
Technical SpecificationsMounting Method 4 Mounting holesPort Connections Inlet / Outlet
1-1/4” Threaded – SAE 20, 1-1/4” BSPP1-1/2” Threaded – SAE 24, 1-1/2” BSPP1-1/2” Flange-SAE-DN 38
Flow Direction Inlet: Side Outlet: Opposite SideConstruction MaterialsHeadBowl
Ductile ironSteel
Flow Capacity160250400
42 gpm (160 lpm)66 gpm (250 lpm)100 gpm (400 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
3000 psi (207 bar)3000 psi (210 bar) @ 1 million cycles10,650 psi (735 bar)
Element Collapse Pressure RatingBH4HCBN4HC, W/HC
3045 psid (210 bar)290 psid (20 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid CompatibilityCompatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 36.25 psid (2.5 bar) -10% (optional) ∆P = 50.75 psid (3.5 bar) +10% (optional)∆P = 72 psid (5 bar) -10% (standard) ∆P = 116 psid (8 bar) -10% (optional) [Used with non-bypass]
Bypass Valve Cracking Pressure∆P = 102 psid (7 bar) +10%
F57
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeFMND BN/HC 250 L D F 10 C 1 . X / 12 - V - .
Filter Type FMND = Inline Duplex Filter
Element Media BH/HC = Betamicron® (High Collapse) BN/HC = Betamicron® (Low Collapse) W/HC = Wire Mesh
Size 160, 250, 400
Operating Pressure L = 3000 psi (210 bar)
Type of Changeover D = segment valve
Type and Size of Port E = 1-1/4” Threaded – SAE 20, 1-1/4” BSPP F = 1-1/2” Threaded – SAE 24, 1-1/2” BSPP K = 1-1/2” Flange-SAE-DN 38
Filtration Rating (micron) 3, 6, 10, 25 = BH/HC 3, 6, 10, 25 = BN/HC 25, 50, 100, 200 = W/HC
Type of ∆P Clogging Indicator A, B, BM, C, D (Others available upon request)
Type Code 1
Modification Number (the latest version is always supplied)
Port Configuration (omit) = SAE DN Flange 0 = BSPP Threaded 12 = SAE Straight Threaded Seals (omit) = Nitrile rubber (NBR) V = Fluorocarbon elastomer (FKM) (standard)
Bypass Valve (omit) = no bypass (optional) B3.5 = 50.75 psid (3.5 bar) (optional) B7 = 101.5 psid (7 bar) (standard)
Supplementary Details L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) RL = Flow Path reversed - Right inlet/Left outlet SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids SO155H = Modification of BH4HC (High Collapse) Element For Phosphate Esters cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation
Replacement Element Model Code0250 DN 010 BN4HC / V .
Size 0160, 0250, 0400
Type DN
Filtration Rating (micron) 3, 6, 10, 25 = BN4HC 25, 50, 100, 200 = W/HC
Element Media BN4HC, W/HC
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Supplementary Details SFREE = (same as above) SO263 = (same as above) SO155H = (same as above)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Clogging Indicator Model CodeVM 8 C . X / V .
Indicator Prefix VM = G 1/2 3000 psi
Trip Pressure 2 = 29 psid (2 bar) (optional) 5 = 72 psid (5 bar) 8 = 116 psid (8 bar)
Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT
Modification Number
Supplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Light Voltage (D type indicators only) L24 = 24V L110 = 110V
Thermal Lockout (VM types C, D, J, and J4 only) T100 = Lockout below 100°F
Underwriters Recognition (VM types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition
(For additional details and options, see Section G - Clogging Indicators.)
F58
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 160 250 400
Weight (lbs.) 52.7 59.8 71.0
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
DimensionsFMND 160/250/400
1305.12
4.17106
FMND 160:11.95303.5
FMND 250:[15.49]393.5
FMND 400:[21.39]543.5
11.02280 LDK[11.10]282 LDE/LDF
1.9750
4.13105
TELTUOTELNI
2.4462
4.9
124.5
4.49114
8.27210
See chart4 Places
2.0552
0.9825
2.2657.5
2.6868
7.58192.5
Dirty sideVent portSW5G 1/8"
Dirty sideVent portSW5G 1/8"
∆P CloggingindicatorPortG 1/2"
Dirty side drain portdrain plug (included)SW8G 3/8"2 Places
[1.26]32HEX
-LDE1 5/8"-12UN-2BSAE-20OR-LDF1 7/8"-12UN-2BSAE-24OR-LDK1 1/2" SAE DN 38FlangeINLET AND OUTLET
2.7569.9
1.4135.7
M12 X 1.75 X 0.75
19 DP4 Places
[3.35]85
Clearance requiredfor element removal
FlangeLDK Version
Model Mounting HoleFMND160-400LDE M12X1.75 x 19mm DeepFMND160-400LDE/12 3/8-24UNF x 14mm DeepFMND160-400LDF M12X1.75 x 19mm DeepFMND160-400LDF/12 3/8-24UNF x 14mm DeepFMND160-400LDK M12X1.75 x 19mm Deep
Before changing the element, relieve pressure in the filter housing.
F59
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Betamicron ...DN…BN/HC Elements (Low Collapse)Size 3µm 6 µm 10 µm 25 µm
0160 DN XXX BN4HC 0.434 0.280 0.187 0.1430250 DN XXX BN4HC 0.280 0.176 0.115 0.0990400 DN XXX BN4HC 0.176 0.110 0.071 0.055
Wire Mesh ...DN…W/HC ElementsSize 25 µm 50 µm 100 µm 200 µm
0160 DN XXX W/HC 0.009 0.009 0.009 0.0090250 DN XXX W/HC 0.006 0.006 0.006 0.0060400 DN XXX W/HC 0.004 0.004 0.004 0.004
Betamicron ...DN…BH/HC Elements (High Collapse)Size 3 µm 6 µm 10 µm 25 µm
0160 DN XXX BH4HC 0.439 0.280 0.209 0.1370250 DN XXX BH4HC 0.296 0.187 0.154 0.1040400 DN XXX BH4HC 0.187 0.115 0.093 0.060
All Element K Factors in psi / gpm.
FMND 160/250/400 LDK
FMND 160/250/400 LDF
1-7/8"-12UN-2BSAE-24 Port
OUTLET & INLET
FMND 160/250/400 LDK
INLET & OUTLETDN38 3000 PSI Flange SAE (1 1/2" Flanged)
[2.75]69.9
[1.41]35.7
[0.75]M12X1.75X19 DP
FMND 160/250/400 LDE
1-5/8"-12UN-2BSAE-20 PortINLET & OUTLET
F60
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Automotive Industrial Pulp & Paper
Railways
PowerGeneration
Steel / HeavyIndustry
Features• The DFDK Filters have a filter head of ductile iron and a screw-in
bowl of cold-formed steel.• The filter housings are designed to withstand pressure surges as
well as high static pressure loads.• The screw-in bowl or lid, allows the filter element to be easily
removed for replacement or cleaning.• A visual (pop-up), electrical, electrical/visual (lamp), or other
electronic differential types of clogging indicators are available to suit each application.
• DFDK filters are available only with high collapse pressure elements since no bypass is provided.
• DFDK sizes 330 and above can be ordered with a T Ball Valve which can operate in mid position with both elements fully open and online in parallel.
DFDK SeriesInline Duplex Filters4568 psi • up to 90 gpm
A
B
A
B
Technical SpecificationsMounting Method 4 mounting holesPort Connection60/110160/240/280330/660/1320
SAE-12SAE-242” SAE-DN 50 Flange
Flow Direction 60 - 280 330 - 1320InletOutlet
TopSide
TopBack
Construction MaterialsHeadBowlHousing (1320)Lid/Cap (1320)
Ductile ironSteelSteelDuctile iron
Flow Capacity60/110160/240/280330/660/1320
13 gpm (50 lpm)35 gpm (132 lpm)90 gpm (340 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
4568 psi (315 bar)Contact HYDAC Office> 18,270 psi (1260 bar)
Element Collapse Pressure RatingBH4HC, V 3045 psid (210 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 116 psid (8 bar) -10% (standard)Non-bypass Only
DFDK…QL “L” Ball Valve
DFDK…QT “T” Ball Valve (sizes 330 or larger)
F61
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeDFDK BH/HC 60 Q L C 3 A 1 . 2 - .
Filter Type DFDK = Duplex Pressure Filter with Ball Valve Selector
Element Media BH/HC = Betamicron® (High Collapse) V = Metal Fiber
Size 60, 110, 160, 240, 280, 330, 660, 1320 (larger sizes available - contact HYDAC)
Pressure Range K = 2320 psi (160 bar) (sizes 1320 with type code 3 only - larger sizes upon request) Q = 4568 psi (315 bar) (sizes 30 - 1320 with type code 1 or 2 only)
Valve L = ball change-over valve in “L” configuration (standard) T = ball change-over valve in “T” configuration
(full simultaneous flow through both sides - sizes 330 and larger)
Connection B = 1/2” SAE 8 (size 30 only) L = 2” SAE DN 50 (sizes 330 - 1320 only) C = 3/4” SAE 12 (sizes 60/110 only) M = 2 1/2” SAE DN 65 (sizes 1320 only) - 3.0 only F = 1 1/2” SAE 24 (sizes 160 - 280 only)
Filtration Rating (micron) 3, 5, 10, 20 = BH/HC 3, 5, 10, 20 = V
Type of ∆P Clogging Indicator A, B, BM, C, D (others available upon request)
Type Code 1 = One Piece Bowl (sizes 60 - 660 only) 2 = Two Piece Bowl (size 660 to 1320 only) 3 = Upside down mounting - Element top access (size 1320 only - larger sizes upon request)
Modification Number (latest version always supplied)
Port Configuration omit = 2” SAE DN 50 Flange Ports (sizes 330-1320 only) 12 = SAE Straight thread O-ring Boss Ports (sizes 60-280 only)
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene Propylene (EPR)
Supplementary Details L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids T100 = Thermal lockout on indicator at 100°F (C, D, J, and J4 indicators only) cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation
Replacement Element Model Code0060 D 003 BH4HC / V
Size 0060, 0110, 0160, 0240, 0280, 0330, 0660, 1320
Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 3, 5, 10, 20 = V
Element Media BH4HC, V
Seals (omit) = Nitrile rubber (NBR) (standard)
V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Supplementary Details SO263 = (same as above) SFREE = (same as above)
W = Modification of “V” elements for use with oil water emulsions (HFA) and water polymer solutions (HFC)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Clogging Indicator Model CodeVD 8 B . X / .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 8 = 116 psid (8 bar)Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F62
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 60 110 160 240 280
Weight (lbs.) 33.1 37.5 72.8 79.4 99.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFDK 60 / 110 / 160 / 240 / 280
220.3
h7 MAX
b13
h8Clearance Requiredfor Element Removal
d4 x t1
G 1/2" Drain
h1
b1
h3
b12 SQ1
b14
h9 b5
b2
h6
b6
h2
h5
0.24
6
HEX 1
HEX 2drain
OUTLETd2
b7
d3
h4
INLETd1
∆P CloggingIndicator PortG 1/2"
b4
b9
b11
b8
b10 Vent Plug G1/8Clean Side
Vent Plug G1/8Dirty Side
F63
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
DFDK 60 110 160 240 280
b1 [5.43] 138 [5.43] 138 [7.48] 190 [7.48] 190 [7.48] 190
b2 [6.69] 170 [6.69] 170 [8.27] 210 [8.27] 210 [8.27] 210
b4 [3.62] 92 [3.62] 92 [5.04] 128 [5.04] 128 [5.04] 128
b5 [1.77] 45 [1.77] 45 [2.07] 52.5 [2.07] 52.5 [2.07] 52.5
b6 [4.78] 121.5 [4.78] 121.5 [6.20] 157.5 [6.20] 157.5 [6.20] 157.5
b7 [2.13] 54 [2.13] 54 [2.97] 75.5 [2.97] 75.5 [2.97] 75.5
b8 [1.02] 26 [1.02] 26 [1.40] 35.5 [1.40] 35.5 [1.40] 35.5
b9 [3.43] 87 [3.43] 87 [4.13] 105 [4.13] 105 [4.13] 105
b10 [1.91] 48.5 [1.91] 48.5 [2.07] 52.5 [2.07] 52.5 [2.07] 52.5
b11 [2.13] 54 [2.13] 54 [2.97] 75.5 [2.97] 75.5 [2.97] 75.5
b12 [0.63] 16 [0.63] 16 [0.39] 10 [0.39] 10 [0.39] 10
b13 (≈) [5.91] 150 [5.91] 150 [7.60] 193 [7.60] 193 [7.60] 193
b14 (≈) [7.13] 181 [7.13] 181 [8.70] 221 [8.70] 221 [8.70] 221
d1*1-1/16-12UN-2B
SAE-121-7/8-12UN-2B
SAE-24d2*
d3 [2.69] 68.2 [2.69] 68.2 [3.75] 95.2 [3.75] 95.2 [3.75] 95.2
d4 1/4-28UNF-2B 3/8-24UNF-2B
h1 [3.07] 78 [3.07] 78 [3.78] 96 [3.78] 96 [3.78] 96
h2 [4.61] 117 [4.61] 117 [6.38] 162 [6.38] 162 [6.38] 162
h3 [0.77] 19.5 [0.77] 19.5 [1.30] 33 [1.30] 33 [1.30] 33
h4 [2.54] 64.5 [2.54] 64.5 [4.17] 106 [4.17] 106 [4.17] 106
h5 [2.99] 76 [2.99] 76 [3.94] 100 [3.94] 100 [3.94] 100
h6 [8.07] 205 [10.89] 276.5 [11.20] 284.5 [13.60] 345.5 [20.69] 525.5
h7 (≈) [8.07] 205 [8.07] 205 [9.65] 245 [9.65] 245 [9.65] 245
h8 [2.95] 75 [2.95] 75 [3.35] 85 [3.35] 85 [3.35] 85
h9 [0.20] 5 [0.20] 5 [0.20] 5 [0.20] 5 [0.20] 5
t1 [0.28] 7 [0.28] 7 [0.43] 11 [0.43] 11 [0.43] 11
HEX1 [1.06] 27 [1.06] 27 [1.26] 32 [1.26] 32 [1.26] 32
HEX2 [0.39] 10 [0.39] 10 [0.39] 10 [0.39] 10 [0.39] 10
SQ1 [0.47] 12 [0.47] 12 [0.55] 14 [0.55] 14 [0.55] 14
Dimensions shown are [inches] millimeters for general information and overall envelope size only.
F64
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 330 660
Weight (lbs.) 213.9 249
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFDK 330 / 660…1.2
1.7544.5
3.8196.8
3/4-10UNC-2B x[0.98] Min. 25 Full Thread4 PL's
8.98228
Approx.
0.6215.7
10.63270
Approx.
INLET / OUTLET Flange
5.13
1525.98
130.2
3.2783
[3.74] 95Clearance required for element removal
PressureEqualizationValve
150
175
325
60.52.38
5.91
12.8
6.89
0.6215.7
Approx.
Indexing plungerfor locking the lever (optional)
Lifting holes [0.67] 1/2-20UNF-2B x 17 DP
INLETSAE 2"(DN50)6000 PSI
∆P Clogging
Clean SideVent Plug G1/8
Dirty SideVent Plug G1/8
indicator portG1/2"
Vent PlugG1/8"
80.31
2007.87
0.24
6
Drain PortG 1/2"
Mountingring size660 only
5.39137
3.8698
OUTLETSAE 2" (DN50) 6000 PSI
295 4.69119 51
209 8.23
823.23
0.59
1295.08 0.79
20
HEX
11.61
1706.69
0.671/2-20UNF-2B X 17 DP
4 PLS
1.42
36
9.65245
SIZE 330[14.51]368.5
SIZE 660[21.18]
538
F65
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 660 1320
Weight (lbs.) 262.5 335.1
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFDK 660 / 1320…2.2
8.98228
Approx.
0.6215.7
10.63270
Approx.
1.7544.5
3.8196.8
3/4-10UNC-2B x[0.98] Min. 25 Full Thread
5.2
SIZE 660[20.91]
531SIZE 1320
[33.58]853
SIZE 660[13.78]
350SIZE 1320
[26.38]670
4.41112
132
1525.98
3.2783
Pressureequalizationvalve
5.39137
3.8698
OUTLETSAE 2" (DN50) 6000 PSI
7.87200
0.24
6
INLET / OUTLET Flange
Drain portG 1/2"
Lifting Holes [0.67]
1/2-20UNF-2B x 17 DP
1505.91
325
6.89
175
12.8
2.38
60.5
0.6215.7
Approx.
INLETSAE 2" (DN50) 6000 PSI
Vent plugG1/8"
Indexingplunger for locking lever(Optional)
∆P CloggingIndicator Port G 1/2"
6.69170
2098.23
0.795.08
1.42 HEX
4 PLS1/2-20UNF-2B X 17 DP
0.67
295
3.23
82
11.61
1194.69
36
20
15 0.59
129
9.65245
Clean SideVent Plug G1/8
Dirty SideVent Plug G1/8
F66
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
00
5
10
15
20
25
30
35
0
0.5
1.0
1.5
2.0
10 20 30
0 20 40 60 80 100
Q (gpm)
DFDK 60 / 110 Housing
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
00
10
20
30
40
50
0
1.5
1.0
0.5
2.0
2.5
3.0
10 20 30 40 50
0 30 60 90 120 150 180
Q (gpm)
DFDK 160 / 240 / 280 Housing
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
00
5
10
15
25
20
30
0
0.5
1.0
1.5
2.0
4020 60 80 100 120 140 160
0 100 200 300 400 500 600
Q (gpm)
DFDK 330 / 660 / 1320 QLL Housing “L” Ball Valve
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
00
5
35
30
25
10
15
20
0
0.50
1.5
1.0
2.0
50 100 150 200 250
0 200 300100 400 500 600 700 800 900
Q (gpm)
DFDK 330 / 660 / 1320 QTL Housing “T” Ball Valve
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
F67
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Metal Fiber ...D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0060 D XXX V 0.877 0.511 0.296 0.1830110 D XXX V 0.452 0.304 0.182 0.1180160 D XXX V 0.251 0.177 0.123 0.0790240 D XXX V 0.169 0.137 0.093 0.0620280 D XXX V 0.126 0.093 0.064 0.0410330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012
Betamicron ...D…BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0060 D XXX BH4HC 3.216 1.789 0.993 0.6700110 D XXX BH4HC 1.394 0.818 0.489 0.3070160 D XXX BH4HC 0.922 0.571 0.324 0.2410240 D XXX BH4HC 0.582 0.373 0.214 0.1590280 D XXX BH4HC 0.313 0.187 0.099 0.0880330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022
All Element K Factors in psi / gpm.
Notes
F68
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Automotive Industrial Pulp & Paper
Shipbuilding
PowerGeneration
Steel / HeavyIndustry
Features• The HFDK4P pressure duplex filter meets HF4 automotive
specification element requirements.• The HFDK4P filters have a filter head and lid of ductile iron
and a cold formed steel housing to meet high fatigue pressure requirements.
• The filter housings are designed to withstand pressure surges as well as high static pressure loads.
• The screw-in lids allow top access for the filter element to be easily removed for replacement.
• Visual (pop-up), electrical, electrical/visual (lamp), or electronic differential type clogging indicators are available.
• HFDK4P filters are available only with high collapse pressure elements with no bypass provided.
HFDK4P SeriesInline Duplex Filters4568 psi • up to 90 gpm
A
B
Technical SpecificationsMounting Method 4 mounting holesPort Connection 2” SAE Flange Code 62Flow Direction Inlet: Bottom Outlet: Left SideConstruction MaterialsHead, LidHousing
Ductile ironSteel
Flow Capacity9”18”27”
50 gpm (189 lpm)75 gpm (284 lpm)90 gpm (340 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
4568 psi (315 bar)4500 psi (315 bar)Contact HYDAC Office
Element Collapse Pressure RatingBH 3045 psid (210 bar)
Fluid Temperature Range 14ºF to 212ºF (-10ºC to 100ºC)Consult HYDAC for applications operating below 14°F (-10°C)
Fluid CompatibilityCompatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 116 psid (8 bar) -10% (standard)∆P = 72 psid (5 bar) -10% (optional)
F69
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model Code HFDK4P BH 27 F 5 C 1 . 2 / 16 A5 V Filter Type HFDK4P = Inline duplex pressure filter
Element Media BH = Betamicon® (High Collapse)
Element Length 09 = 9 inches 18 = 18 inches 27 = 27 inches
Type of Connection F = Flanged
Filtration Rating (micron) 3, 5, 10, 20 = BH
Type of Clogging Indicator A, B/BM, C, D
Type Code 1
Modification Number (the latest version is always supplied)
Port Configuration 16 = 2” SAE 4 bolt flange (code 62)
Indicator Trip Pressure (omit) = 116 psid (8 Bar) (standard) A5 = 72 psid (5 Bar)
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Supplementary Details SO155H = Modification of BH elements for phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100ºF (C and D indicators only) cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Replacement Element Model Code 5 . 03 . 27 D 05 BH /-V Length (nominal inches) 09, 18, 27Filtration Rating (micron) 3, 5, 10, 20 = BHElement Media BHSeals (omit) = Nitrile rubber (NBR) (standard)
V = Fluorocarbon elastomer (FKM) Supplementary Details SFREE = (same as above)
Clogging Indicator Model CodeVD 8 C . X / V .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 5 = 72 psid (5 bar) (optional) 8 = 116 psid (8 bar) (standard)
Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and led light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) V = Fluorocarbon elastomer (FKM) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F70
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 09 18 27
Weight (lbs.) 233.7 270.5 306.4
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
1.7544.5
3.8196.8 SAE Flange
2" SAE CODE 62
3/4"-10UNC-2Bx 25DP
10.65270.5
(7/16-20 UNF)SAE-4Vent Plug
Drain Plug Dirty sideSAE-8(3/4-16UNF)
178
3.27
45
0.88 22.4
1.77
18 696.1
457.8
27 934.6
[27.41]
[36.79]
18.02
83
7.01
5.25
12.80325
133.4
HFDK4P-09
0.6115.6
163
6.42
1.5740
1195.08129
82 3.23
4.69
1.0025.4HEX
PressureEqualizationValve
5.39 137
8.23 209
4.02102
OUTLET
1/2"-20UNF-2B x 17DPINLET
1756.89
5.85
11.61295
6.69170
148.5
0.5915
148.5 5.85
7.87200
[12.00]HFDK4P-09 305 [21.00] 18 533 [30.00] 27 762Clearance requiredfor element removal
DimensionsHFDK4P 09, 18, 27…1.2
F71
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
00
2
4
12
10
8
6
14
18
16
20
0
0.2
0.4
0.6
0.8
1.0
1.2
10 20 4030 6050 8070 90
0 50 150100 200 250 300
Q (gpm)
HFDK4P Housing
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K FactorsP Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Autospec HF4 Depth 5.03.XXDXXBH (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
5.03.09DXXBH 0.207 0.146 0.089 0.0475.03.18DXXBH 0.097 0.068 0.041 0.0225.03.27DXXBH 0.063 0.044 0.027 0.014
All Element K Factors in psi / gpm.
F72
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction Industrial
Railways
Features• DFFH Reverse bypass Flow models filter fluid in the forward
direction and bypass the filter element when the flow direction is reversed.
• DFFHM Bi-Directional model provides fluid filtering in both directions. There are separate filter elements for each direction.
• Inlet/outlet port options include SAE 4-bolt flange code 62, or SAE ports (DFFHM flange only) to allow easy installation without costly adapters.
• O-ring seals are used to provide positive, reliable sealing. A choice of O-ring materials (nitrile rubber, Fluorocarbon elastomer, and ethylene propylene rubber) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.
• Screw-in bowl or lid, mounted below the filter head requires minimal clearance to remove the element for replacement; contaminated fluid cannot be washed downstream when element is serviced.
• Clogging indicators have no external dynamic seal. This results in high reliability due to magnetic actuation which eliminates a leak point.
• A poppet-type bypass valve, located in filter head, (optional) provides positive sealing during normal operation and fast opening during cold starts and flow surges.
DFFH & DFFHM SeriesReverse Flow Bypass & Bi-Directional Filters6090 psi • up to 100 gpm
DFFH FILTERREVERSE FLOW
CIRCUIT
DFFHM FILTERBI-DIRECTIONAL
CIRCUIT
BY-PASSVALVES
(OPTIONAL)
Technical SpecificationsMounting Method DFFH: 4 mounting holes
DFFHM: 8 mounting holesPort ConnectionDFFH 160/240/280DFFH 330/660/1320DFFHM 160/240/280DFFHM 330/660/1320
SAE-20, 1 1/4” SAE Flange Code 62SAE-24, 2” SAE Flange Code 621 1/4” SAE Flange Code 622” SAE Flange Code 62
Flow Direction Inlet: Side Outlet: SideConstruction MaterialsHeadSingle piece bowl “1.X” BowlTwo piece bowl “2.X” Housing Lid/Cap
Ductile iron
Steel
SteelSteel
Flow Capacity160240280330660/1320
42 gpm (160 lpm)63 gpm (240 lpm)74 gpm (280 lpm)87 gpm (330 lpm)100 gpm (378.5 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
6090 psi (420 bar)6000 psi (420 bar)Contact HYDAC Office
Element Collapse Pressure RatingBH4HC, VON, W/HC
3045 psid (210 bar)290 psid (20 bar)
Fluid Temperature Range 14ºF to 212ºF (-10ºC to 100ºC)Consult HYDAC for applications operating below 14°F (-10°C)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)∆P = 116 psid (8 bar) (non-bypass appplication)
Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standard)
F73
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Clogging Indicator Model CodeVD 5 B . X / .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 116 psid (8 bar) available upon request
Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
Model CodeDFFH BH/HC 160 G 3 B 1 . 0 / 12 .
Filter Type DFFH = Reverse Flow bypass Filter DFFHM = Bi-Directional Filter
Element Media ON = Optimicron® (Low Collapse) BH/HC = Betamicron® (High Collapse) W/HC = Wire Mesh V = Metal Fiber
Size and Nominal Connection DFFH DFFHM 160 = 1 1/4” SAE Port or Flange 160 = 1 1/4” Flange (only) 240 = 1 1/4” SAE Port or Flange 240 = 1 1/4” Flange (only) 280 = 1 1/4” SAE Port or Flange 280 = 1 1/4” Flange (only) 330 = 1 1/2” SAE Port or 2” Flange 330 = 2” Flange (only) 660 = 1 1/2” SAE Port or 2” Flange 660 = 2” Flange (only) 1320 = 1 1/2” SAE Port or 2” Flange 1320 = 2” Flange (only)
Type of Connection G = Threaded (not available for DFFHM) F = Flange
Filtration Rating (micron) 3, 5, 10, 20 = BH/HC, BN/HC 3, 5, 10, 20 = V 1, 3, 5, 10, 15, 20 = ON 25, 74, 149 = W/HC
Type of ∆P Clogging Indicator A, B, BM, C, D (Others available upon request)
Type Number 1 2 = 2 Piece Bowl (size 660/1320 only)
Modification Number (latest version is always supplied)
Port Configuration 12 = SAE Straight Thread O-Ring Boss Ports (available on DFFH only) 16 = SAE Flange Ports
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene Propylene rubber (EPR)
Bypass Valve (omit) = Non-bypass - Critical applications (high collapse element required) B3 = 43 psid (3 bar) - Optional B6 = 87 psid (6 bar) - Standard setting for pressure filters
Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluid SO184 = G-1/2” Drain in Bowl Option For Sizes 160 - 280 (standard for sizes 330 & 660) W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100°F (C and D indicators only) cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation
Replacement Element Model Code 0160 D 003 BH4HC / Size 0160, 0240, 0280, 0330, 0660, 1320
Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = V 25, 74, 149 = W/HC
Element Media BH4HC, ON, V, W/HC
Seals (omit) = Nitrile rubber (NBR) (standard)
V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Supplementary Details SO263 = (same as above) SFREE = (same as above)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
F74
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size - DFFH 160 240 280
Weight (lbs.) 25.6 29.2 39.6
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFFH 160 / 240 / 280
4.57116
(Optional)
SAE 20 Flange code62 (1-1/4")
Drain PortG 1/2"
SAE 20 Thread or
[1.00]1/2"-13UNC-2B x 25.4 DP4 Places
66.72.63
1.2531.8
∆P Clogging Indicator PortG 1/2"
DFFH 240 12.05306
0.24
3.75
95.2
1.85
47.1
6
[19.17]DFFH 280 487
[9.68]DFFH 160 246
HEX 1.2632
4 Places
INLET
Mounting Holes [0.55]3/8-24UNF-2B x 14
OUTLET
3.3585
35 1.38
142.9
98.63.88
5.63
0.5614.2
for Element Removal
85Clearance required
[3.35]
F75
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
6.26159
∆P CloggingIndicator PortG 1/2"
0.24
[13.19]
6
130.2
177.4 6.98
19.88DFFH 330 335
DFFH 660
2.39
505
60.7
5.13HEX
1.4236
Two Piece Bowl
Clearance required
SAE Ported Version
for element removal
for element removal
DFFH 660 & 1320 2.X
95[3.74]
Clearance required
OUTLET
Flow)(FilteredINLET
[0.67]1/2-20UNF-2B IN. x 17 DP
6.3 160
4.53
115138
60 2.36
5.43
0.7118
Drain PortG 1/2"
1-7/8-12UNCSAE-24 PORT
G 1/2"Drain Port
Or SAE 32 flange code 62 (2")
SAE 24 Thread
[0.95]3/4-10UNC-2B x 24 DP4 Places
DFFH 1320 820 [32.28]
5.98
44.5
19.57497
2.3960.7
1124.41
1.75
DFFH 660
1325.2
152
3.8196.8
DFFH 1320 670 [26.38]
13.78350DFFH 660
0.24
6
Size - DFFH 330 660 1320
Weight (lbs.) 61.3 78.7 127
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFFH 330 / 660 / 1320
F76
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size - DFFHM 160 240 280
Weight (lbs.) 59.1 66.3 77
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFFHM 160 / 240 / 280
0.24
6
DFFHM 160 F 9.68
246 [12.05]DFFHM 240 F 306 [19.17] DFFHM 280 F 487
3.7595.2
16.73425
1.8547
HEX 1.2632
Drain PortG 1/2"(Optional)
5.63
142.9
3.3585
1.6742.5
5.47139
1.3835
11.1282
Mounting holes
3/8-24UNF-2B x0.5514
8 Places
0.6918
0.5614.2
0.5614.2
4.57116
∆ P Clogging Indicator PortG 1/2"2 Places
A3Flange bolt holes(4 Places)
A2
A1
[3.35]85Clearance requiredfor element removal
Size A1 A2 A3DFFHM 160/240/280 66.7±0.3 31.8±0.3 1/2-13UNC-2B x [1.00] 25.4 DP
F77
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size - DFFHM 330 660
Weight (lbs.) 139.4 175.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFFHM 330 / 660
13.07332
6.77172
6.3160
2.3660
4.53115
2.2657.5
Mounting Holes
1/2-20UNF-2B x0.6717 DP
4 Places
0.7118
1.1830
6.26159
∆P CloggingIndicator Port G 1/2"2 Places
Inlet
0.24
6
DFFHM 300 [13.19]335
[19.88]DFFHM 660 505
2.3960.7
5.13130.2
HEX 1.4236
19.37492
A3Flange bolt holes(4 Places)
A2
A1
Drain PortG 1/2"
[3.74]95Clearance requiredfor element removal
Size A1 A2 A3DFFHM 160/240/280 66.7±0.3 31.8±0.3 1/2-13UNC-2B x [1.00] 25.4 DP
F78
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size - DFFHM 1320
Weight (lbs.) 271.2
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFFHM 1320
3/4-10UNC-2B x 0.9424 DP
1.9750
3.8196.8
1.7544.5
Flange Detail
6.26159
332 13.07
57.5
4.53
160 172
115
1.18
30
602.36
6.77 2.26
6.30
19.37492
6
5.98
60.7
819.4
2.39
132
152
32.26
5.20
[0.24]
4.41112
Drain PortG 1/2"
Indicator PortG 1/2"
HEX 1.4236
[26.38]670
Clearance Requiredfor Element Removal
F79
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
0.0
20.0
15.0
10.0
5.0
0 15 30 45 60 75 90Flow in gpm
DFFH 330/660/1320 Reverse Flow
0.0
20.0
15.0
10.0
5.0
0 20 40 60 80 100Flow in gpm
DFFH 330/660/1320 Forward FlowDFFH 160/240/280 Forward Flow
0 806040200
40
30
20
10
Flow in gpm
DFFH 160/240/280 Reverse Flow
0 806040200
40
30
20
10
Flow in gpm
DFFHM 330/660/1320 Forward & Reverse Flow
Flow in gpm0 150100500
50
40
30
20
10
DFFHM 160/240/280 Forward & Reverse Flow
Flow in gpm0
150
100
50
0 80604020
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0160 D XXX ON 1.015 0.604 0.423 0.225 0.204 0.1750240 D XXX ON 0.631 0.379 0.293 0.175 0.134 0.1150280 D XXX ON 0.304 0.185 0.15 0.082 0.075 0.0640330 D XXX ON 0.452 0.23 0.185 0.135 0.085 0.0670660 D XXX ON 0.207 0.106 0.086 0.051 0.039 0.0311320 D XXX ON 0.102 0.053 0.042 0.025 0.019 0.015
Betamicron ...D…BH4HC (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0160 D XXX BH4HC 0.922 0.571 0.324 0.2410240 D XXX BH4HC 0.582 0.373 0.214 0.1590280 D XXX BH4HC 0.313 0.187 0.099 0.0880330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022
Metal Fiber ...D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0160 D XXX V 0.251 0.177 0.123 0.0790240 D XXX V 0.169 0.137 0.093 0.0620280 D XXX V 0.126 0.093 0.064 0.0410330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012
Wire Mesh ...D…W/HC Elements Size 25, 50, 74, 100, 149, 200 µm
0160 D XXX W/HC 0.0160240 D XXX W/HC 0.0100280 D XXX W/HC 0.0090330 D XXX W/HC 0.0080660 D XXX W/HC 0.0041320 D XXX W/HC 0.002
All Element K Factors in psi / gpm.
F80
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Industrial Railways Steel / HeavyIndustry
Features• The DF...QE Filters have a filter head of ductile iron and a
screw-in bowl of cold-formed steel for high fatigue strength.• The filter housings are designed to withstand pressure surges
as well as high static pressure loads.• The screw-in bowl or lid/cap allows the filter element to be easily
removed for replacement or cleaning.• Visual (pop-up), electrical, electrical/visual (lamp), or electronic
differential type clogging indicators can be installed.• DF...QE filters are available with or without a bypass valve
located in filter head, so either high or low collapse pressure elements may be used.
• Fatigue pressure rating equals maximum allowable working pressure rating.
DF...QE SeriesManifold Mount Filters4568 psi • up to 110 gpm
A
B
Technical SpecificationsMounting Method 4 mounting holes (manifold mount)
Port Connection Diameters3060/110160/240/280330/660/1320
0.551” (14mm)0.787” (20mm)1.260” (32mm)1.181” (30mm)
Flow Direction Inlet: Side Outlet: SideConstruction MaterialsHeadSingle piece bowl “1.X” BowlTwo piece bowl “2.X” Housing Lid/Cap
Ductile iron
Steel
SteelSteel
Flow Capacity30601101602402803306601320
8 gpm (30 lpm)16 gpm (60 lpm)29 gpm (110 lpm)42 gpm (160 lpm)63 gpm (240 lpm)74 gpm (280 lpm)87 gpm (330 lpm)100 gpm (378.5 lpm)110 gpm (416.4 lpm)
Housing Pressure Rating QE MHEMax. Allowable Working PressureFatigue Pressure
Burst Pressure
4568 psi (315 bar)4568 psi (315 bar) @ 1 mil. cyclesContact HYDAC
3625 psi (250 bar)3625 psi (250 bar) @ 100 mil. cycles
Element Collapse Pressure RatingBH4HC, VON, W/HC
3045 psid (210 bar)290 psid (20 bar)
Fluid Temperature Range 14ºF to 212ºF (-10ºC to 100ºC)Consult HYDAC for applications operating below 14°F (-10°C)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)
Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standard)
F81
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeDF BH/HC 30 Q E 3 B 1 . X / .
Filter Type DF
Element Media ON = Optimicron® (Low Collapse) BH/HC = Betamicron® (High Collapse) V = Metal Fiber W/HC = Wire Mesh
Size 30, 60, 110, 160, 240, 280, 330, 660, 1320
Operating Pressure Q = 4500 psi (300 bar) MH = 3625 psi (250 bar) (high dynamic @ 100 million cycles)
Type of Connection E = Manifold Block Mounting - Side of Filter Head - 4 mounting holes
Filtration Rating (microns) 3, 5, 10, 20 = BH/HC 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = V 25, 74, 149 = W/HC
Type of ∆P Clogging Indicator A, B, BM, C, D (Others available upon request)
Type Number 1 = Filters with one piece bowls (sizes 30-660) 2 = Filters with two piece bowls (sizes 660-1320)
Modification Number (the latest version is always supplied)
Seals (omit = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Bypass Valve (omit) = Without Bypass (BH4HC or V elements recommended) B3 = 43 psid Bypass (optional) B6 = 87 psid Bypass (standard)
Supplementary Details SO263 = Modification of ON, BH/HC & W/HC elements for Skydrol or HYJET phosphate ester fluids SO184 = G-1/2 Drain in Bowl Option For Sizes 30 - 280 (standard for sizes 330 - 1320) W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100°F (C and D indicators only) SFREE = Element specially designed to minimize electrostatic charge generation cRUus = Electrical Indicator with underwriter’s recognition
Replacement Element Model Code 0030 D 003 BH4HC / Size
0030, 0060, 0110, 0160, 0240, 0280, 0330, 0660, 1320
Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = V 25, 74, 149 = W/HC
Element Media BH4HC, ON, V, W/HC
Seals (omit) = Nitrile rubber (NBR) (standard)
V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Supplementary Details SO263 = (same as above) SFREE = (same as above)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Clogging Indicator Model CodeVD 5 B . X / .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 116 psid (8 bar) available upon request
Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F82
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 30 60 110 160 240 280
Weight (lbs.) 6.4 11.5 13.5 21.2 25.6 35.1
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DF 30 – 280 QE 1.X
[4.57]
DF 30 QE[2.64]
67
DF 60/110 QE[3.31]
84
DF 160/240/280 QE
116
[4.37]
DF 160/240/280 QE
DF 30 QE[3.15]
80
DF 60/110 QE
110
[2.83]
DF 160/240/280 QE
DF 30 QE[2.44]
57
DF 60/110 QE
72
111
DF 30 QE[3.66]
93
DF 60/110 QE[4.37]
DF 160/240/280 QE
HEX
6.22
DF30 QE
DF60/110
158
DF160/240/280
DF30 QE
DF60/110QE
DF160/240/280 QE
Indicator PortG 1/2"
Clearance required
48
[3.75]
DF 30 QE
85
79 [3.11]
DF 280 QE
[2.17]
[1.38]DF60/110 QE
28[1.10]
Mounting Pattern
DF 160 QE
55DF 160/240/280 QE
[1.26]DF 160/240/280 QE
[1.50]
75 [3.35]DF 160/240/280
35DF 160/240/280 QE
[1.77]
for element removal
45DF60/110 QE
[1.06]DF60/110 QE 27
95.2
38
[1.89]
68.2524
343[13.50]
DF 240 QE283
[2.05]
60
[20.62]
[11.14]
DF 30/60/110 [2.95]
32
DF 30 QE
52
[2.36]
DF 30 QE[7.72]196
DF 60 QE[8.62]219
DF 110 QE[11.34]
288
[0.94]DF30 QE 24
[2.05]52.2[2.68]
(Optional SO184)
OUTLET
Drain PortG 1/2" DF60-280G 1/4" DF30
INLET
5.51140
22
DF 160/240/280 QE[0.866]
[0.709]18
DF 30 QE[0.512]
13DF 60/110 QE
DF 30 QE DF 60/110 QE [0.551] [0.79] 14 20 DF 160/240/280 QE [1.26] 32
3.7495
F83
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 330 660
Weight (lbs.) 50.5 75.2
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DF 330 – 660 QE 1.X
DF 330 QE 14.06
357
DF 660 QE [20.70] 526
0.16
4
HEX 1.4236
[4.53]115Clearance requiredfor element removal
5.12130
1546.06
3.1379.5
G 1/2" (Standard)Drain Port
2.0552
95
2.28
3.74
1405.51
58
0.9123
Indicator PortG 1/2"
OUTLET
INLET
F84
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 660 1320
Weight (lbs.) 50.5 75.2
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DF 660 – 1320 QE 2.X
HEX1.4236
Indicator PortG 1/2"
∆ P Clogging
Drain PortG 1/2"
3.13
5.2
79.5
132
6.16
156.5
for elemental removalClearance required650 DF1320 QE
[13.82]351 DF 660 QE
[25.59]
40.16
2.2858
[20.31]
2.0595
DF 1320 QE
5.98
32.99
DF 660 QE 516
4.41
152
112
1405.51
838
3.74
52
6.06154
F85
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
DF...QE 30
0.4
0 0.0
24
18
12
6
0.8
1.2
1.60
0
10 20 30 40 50 60
161284
Q in l/min
Q in gpm Q in gpm
DF...QE 60/110Q in l/min
0
3
6
9
0.2
0.4
0.60 10 20 30 40 50 60 70
0 3 6 9 12 15 18
DF...QE 330/660/1320Q in l/min
0.40
27
18
9 0.8
1.2
1.4
1.60
0 44 66 88 110 13222
100 200 300 400 500
DF...QE 160/240/280Q in l/min
0.1
0.2
0.3
0.4
0.50 40 80 120 160
0 186 12 30 3624 420
7.5
5.0
2.5
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Wire Mesh ...D…W/HC Elements (Low Collapse)Size 25, 50, 74, 100, 149, 200 µm
0030 D XXX W/HC 0.1660060 D XXX W/HC 0.0420110 D XXX W/HC 0.2300160 D XXX W/HC 0.0160240 D XXX W/HC 0.0100280 D XXX W/HC 0.0090330 D XXX W/HC 0.0080660 D XXX W/HC 0.004
1320 D XXX W/HC 0.002
Betamicron ...D…BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0030 D XXX BH4HC 5.005 2.782 1.992 1.0430060 D XXX BH4HC 3.216 1.789 0.993 0.6700110 D XXX BH4HC 1.394 0.818 0.489 0.3070160 D XXX BH4HC 0.922 0.571 0.324 0.2410240 D XXX BH4HC 0.582 0.373 0.214 0.1590280 D XXX BH4HC 0.313 0.187 0.099 0.0880330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022
Metal Fiber ...D…V Elements (High Collapse)
Size 3 µm 5 µm 10 µm 20 µm0030 D XXX V 1.011 0.740 0.411 0.2000060 D XXX V 0.877 0.511 0.296 0.1830110 D XXX V 0.452 0.304 0.182 0.1180160 D XXX V 0.251 0.177 0.123 0.0790240 D XXX V 0.169 0.137 0.093 0.0620280 D XXX V 0.126 0.093 0.064 0.0410330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012
Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0030 D XXX ON 4.27 3.507 2.376 1.251 0.768 0.620060 D XXX ON 2.936 1.427 1.004 0.664 0.537 0.3470110 D XXX ON 1.416 0.735 0.527 0.333 0.254 0.1640160 D XXX ON 1.015 0.604 0.423 0.225 0.204 0.1750240 D XXX ON 0.631 0.379 0.293 0.175 0.134 0.1150280 D XXX ON 0.304 0.185 0.15 0.082 0.075 0.0640330 D XXX ON 0.452 0.23 0.185 0.135 0.085 0.0670660 D XXX ON 0.207 0.106 0.086 0.051 0.039 0.0311320 D XXX ON 0.102 0.053 0.042 0.025 0.019 0.015
All Element K Factors in psi / gpm.
F86
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Construction Industrial
Railways
PowerGeneration
Steel / HeavyIndustry
Features• The filter housings are designed to withstand pressure surges as
well as high static pressure loads.• The screw-in bowl or lid/cap allows the filter element to be easily
removed for replacement or cleaning.• A visual (pop-up), electrical, electrical/visual (lamp), or electronic
differential type clogging indicator can be installed.• DFP filters are available with or without a bypass valve (located in
filter head) so either high or low collapse pressure elements may be used.
• Multiple indicator port locations (DFP330/660/1320 only) also allow two different types of indicators to be installed into the filter. Indicators of the same type, but with different trip pressures can also be installed. (both ports machined and plugged)
• Fatigue pressure rating equals maximum allowable working pressure rating.
DFP SeriesManifold Mount Filters4568 psi • up to 125 gpm
A
B
Technical SpecificationsMounting Method 60 - 280 330 - 1320
(manifold mount)4 mounting holes6 mounting holes
Port Connection Diameter60/110160/240/280330/660/1320
0.689” (17.5mm)0.843” (21.4mm)1.181” (30mm)
Flow Direction Inlet: Top Outlet: Top Construction Materials Head Bowl Housing (660-1320) Cap/Lid (660-1320)
Ductile ironSteelSteelLow Carbon Steel
Flow Capacity 60 110 160 240 280 330 660 1320
16 gpm (60 lpm)29 gpm (110 lpm)42 gpm (160 lpm)63 gpm (240 lpm)74 gpm (280 lpm)87 gpm (330 lpm)174 gpm (660 lpm)180 gpm (680 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue Pressure
4568 psi (315 bar)4568 psi (315 bar) @ 1 milllion cycles
Burst Pressure 60/110160/240/280330/660/1320
15,805 psi (1090 bar)>18,000 psi (1240 bar)15,660 psi (1080 bar)
Element Collapse Pressure RatingBH4HC, VON, W/HC
3045 psid (210 bar)290 psid (17 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.Indicator Trip Pressure ∆P = 29 psid (2 bar) -10% (optional) ∆P = 72 psid (5 bar) -10% (standard)
Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional))∆P = 87 psid (6 bar) +10% (standard)
F87
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeDFP BH/HC 60 Q B 3 B 1 . X / V .
Filter Type DFP = Manifold mount filter
Element Media ON = Optimicron® (Low Collapse) BH/HC = Betamicron® (High Collapse) W/HC = Wire Mesh V = Metal Fiber
Size and Nominal Port Dimension 60 = 3/4” 280 = 1” 110 = 3/4” 330 = 1 1/4” 160 = 1” 660 = 1 1/4” 240 = 1” 1320 = 1 1/4”
Operating Pressure Q = 4500 psi (315 bar)
Port Size B = 0.69 (sizes 60 - 110) C = 0.84 (sizes 160 - 280) D = 1.18 (sizes 330 - 1320)
Filtration Rating (microns) 3, 5, 10, 20 = BH/HC 3, 5, 10, 20 = V 25, 74, 149 = W/HC 1, 3, 5, 10, 15, 20 = ON
Type of ∆P Clogging Indicator A, B, BM, C, D (others available upon request)
Type Number 1 = Single piece bowl (sizes 60 - 660) 2 = Two piece bowl (size 330, 660 & 1320 only)
Modification Number (the latest version is always supplied)
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Bypass Valve (omit) = Without Bypass (BH4HC or V elements recommended) B3 = 43 psid Bypass (optional) B6 = 87 psid Bypass (standard)
Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids SO184 = G-1/2 Drain in Bowl Option For Sizes 60 - 280 (standard for sizes 330, 660, & 1320) W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100°F (C and D indicators only) SFREE = Element specially designed to minimize electrostatic charge generation cRUus = Electrical Indicator with underwriter’s recognition
Replacement Element Model Code 0060 D 003 BH4HC / V Size 0060, 0110, 0160, 0240, 0280, 0330, 0660, 1320
Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 25, 74, 149 = W/HC 3, 5, 10, 20 = V 1, 3, 5, 10, 15, 20 = ON
Element Media BH4HC, ON, V, W/HC
Seals (omit) = Nitrile rubber (NBR) (standard)
V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Supplementary Details SO263 = (same as above) SFREE = (same as above)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Clogging Indicator Model CodeVD 5 B . X / V .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 116 psid (8 bar) available upon request
Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F88
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 60 110 160 240 280
Weight (lbs.) 11.3 13.3 20.1 23 32.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFP 60 – 280…1.X
60/110 160/240/260 [4.09] [4.53] 104 115
DFP 60/110 [2.95] 75DFP 160/240/280 [3.35] 85Clearance requiredfor element removal
HEX
P Clogging Indicator PortG 1/2"
∆
G 1/2"Drain PlugOptional (SO184)
68.2
DFP 280 444
DFP 160 203
DFP [17.48] 3.75
95.2
10.35263DFP 240
[7.99]
160/240/280
[6.30]DFP 60 160 [9.06]DFP 110 230
DFP [2.68] 60/110
0.24
6
[1.06] DFP60/110 27
DFP 160/240/280 1.26
32
OUTLET
INLET
b14
b9
b10
Mounting Holesd4 THRU
4 Places
b13
b3 b5
b6
b7
b11
b15
b4
b12
b8
D5 x T1/T2Mounting Holes4 Places
60 / 110 160 / 240 / 280
B3 [3.15] 80
[4.33] 110
B4 [3.50] 89
[3.54] 90
B5 [1.25] 31.8
[3.39] 86
B6 – [2.40] 61
B7 – [2.24] 57
B8 [1.24] 31.6
[1.50] 38
B9 – [0.55] 14
B10 [0.30] 7.5
[0.49] 12.5
B11 [2.20] 55.9
[2.26] 57.5
B12 – [0.35] 9
B13 [0.95] 24.1
[0.47] 12
B14 – [1.04] 26.5
B15 – [0.41] 10.5
ø d4 [0.33] 8.5
[0.35] 9
ø d5 - 7/16-14UNC-2B
t1 - [0.51] 13
Inlet [0.639] 17.5
0.843” 21.4
Outlet [0.689] 17.5
[0.843] 21.4
F89
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 330 660
Weight (lbs.) 46.3 64
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFP 330/660…1.X
0.7519
96.8 3.81
48.4 1.91
21.40.84
301.18
50.7
1.18
2.00
306 Places
HolesMounting
11.50.45
84.1
3.31
42.11.66
16.70.66
Pin Hole)(Locating
60.24
6.61168
element
INLET
OUTLET
required for
removal
[3.74]95
Clearance
∆ P Clogging Indicator PortsG 1/2" 2 Places(Both Machined)
G 1/2"Drain Plug
20.24514
1586.22
[13.54]DFP 330 344
DFP 660
5.13130.2
HEX 1.4236
F90
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 660 1320
Weight (lbs.) 64 103.9
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DFP 660 & 1320…2.X
HEX 1.4236
G 1/2"Drain Plug
5.20132
∆ P Clogging Indicator Ports G 1/2"2 Places(Both Machined)
DFP 1320 32.48
152
6.22
DFP 660 503
5.98
825
158
[19.80]
4.41112
OUTLET
INLET
[13.78]DFP 660 350
[26.38] DFP 1320 670
Clearancerequired
for elementremoval
6 Places
0.45
Mounting Holes0.66
1.1896.8
3.81
190.75
50.72.0021.4
0.84
48.41.91
42.1
1.66
11.51.18
3.31
30
84.1
30
16.7
6.61168
F91
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
30
20
10
0 5 10 15 20 25 30Q in gpm
DFP 60/110 Housing
60
40
20
DFP 160/240/280 Housing
Q in gpm0 10 20 30 40 50 60 0 50 100 150 200
30
20
10
DFP 330/660/1320 Housing
Q in gpm
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Wire Mesh ...D…W/HC Elements (Low Collapse)Size 25, 50, 74, 100, 149, 200 µm
0060 D XXX W/HC 0.0420110 D XXX W/HC 0.2300160 D XXX W/HC 0.0160240 D XXX W/HC 0.0100280 D XXX W/HC 0.0090330 D XXX W/HC 0.0080660 D XXX W/HC 0.0041320 D XXX W/HC 0.002
Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
0060 D XXX ON 2.936 1.427 1.004 0.664 0.537 0.3470110 D XXX ON 1.416 0.735 0.527 0.333 0.254 0.1640160 D XXX ON 1.015 0.604 0.423 0.225 0.204 0.1750240 D XXX ON 0.631 0.379 0.293 0.175 0.134 0.1150280 D XXX ON 0.304 0.185 0.15 0.082 0.075 0.0640330 D XXX ON 0.452 0.23 0.185 0.135 0.085 0.0670660 D XXX ON 0.207 0.106 0.086 0.051 0.039 0.0311320 D XXX ON 0.102 0.053 0.042 0.025 0.019 0.015
Betamicron ...D…BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0060 D XXX BH4HC 3.216 1.789 0.993 0.6700110 D XXX BH4HC 1.394 0.818 0.489 0.3070160 D XXX BH4HC 0.922 0.571 0.324 0.2410240 D XXX BH4HC 0.582 0.373 0.214 0.1590280 D XXX BH4HC 0.313 0.187 0.099 0.0880330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022
Metal Fiber ...D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0060 D XXX V 0.877 0.511 0.296 0.1830110 D XXX V 0.452 0.304 0.182 0.1180160 D XXX V 0.251 0.177 0.123 0.0790240 D XXX V 0.169 0.137 0.093 0.0620280 D XXX V 0.126 0.093 0.064 0.0410330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012
All Element K Factors in psi / gpm.
F92
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction Industrial
Railways PowerGeneration
Steel / HeavyIndustry
Features• A visual (pop-up), electrical, electrical/visual (lamp) differential
type clogging indicator can be installed.• The DFZ filter can be ordered with the bowl on the left or the
right side for easy element changeout.• The DFZ filter is available in two mounting patterns to fit
different hydraulic manifolds: ANSI/B93.7M-D03 / Cetop R35 (was B93.7-D01) DF 30 Z ANSI/B93.7M-D05 / Cetop R35 (was V93.7-D02)* DF 60 Z or DF 110 Z *includes fifth port for optional tank connection
• Filter does not contain a bypass valve. Only available with non bypass, high collapse elements required.
DFZ SeriesModular Stacking Filters4568 psi • up to 10 gpm
INLETT A B TP
OUTLET
INLETT A BP
OUTLET
Technical SpecificationsMounting Method 4 mounting holes (manifold mount)
Port Connection30 ø.25”60/110 ø.44”
ANSI DO3/A6 DIN 24340 / Cetop R35ANSI DO5/A10 DIN 24340 / Cetop R35
Flow Direction Inlet: Side Outlet: Side Construction MaterialsHead, Bowl Steel
Flow Capacity30 6 gpm (23 lpm)60/110 10 gpm (38 lpm)
Housing Pressure RatingMax. Allowable Working Pressure 4568 psi (315 bar)Fatigue Pressure 30
60/110
4568 psi (315 bar) @ 250,000 cycles4568 psi (315 bar) @ 1 million cycles
Burst Pressure > 18,270 psi (1260 bar)Element Collapse Pressure RatingBH4HC, V 3045 psid (210 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 116 psid (8 bar) -10% (standard)
F93
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model Code DFZ BH/HC 60 Q C 10 B 1 . 0 / - 1 - Filter Type DFZ = Pressure Filter
Element Media BH/HC = Betamicron® (High Collapse) V = Metal Fiber
Size & Connection 30 = D03 manifold pattern 60 = D05 manifold pattern 110 = D05 manifold pattern
Operating Pressure Q = 4500 psi (315 bar) (all sizes)
Type / Port Size B = 4 ports / A 6 DIN 24340/Cetop R 35 H (DFZ 30 only) .25” dia. C = 5 ports / A 10 DIN 24340/Cetop R 35 H (DFZ 60 & 110 only) .44” dia.
Filtration Rating (micron) 3, 5, 10, 20 = BH/HC 3, 5, 10, 20 = V
Type of ∆P Clogging Indicator A, B, BM, C, D (others available upon request)
Type Number 1
Modification Number (latest version is always supplied)
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Bowl Location (omit) = Right Side (standard) 1 = Left Side
Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) SFREE = Element specially designed to minimize electrostatic charge generation cRUus = Electrical Indicator with Underwriter’s Recognition
Replacement Element Model Code 0060 D 010 BH4HC / Size 0030, 0060, 0110
Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 3, 5, 10, 20 = V
Element Media BH4HC, V
Seals (omit) = Nitrile rubber (NBR) (standard)
V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Supplementary Details SO263 = (same as above)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Clogging Indicator Model CodeVD 8 B . X / .
Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 8 = 116 psid (8 bar)Type of Indicator B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and led light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L48 = 48V L110 = 110V L220 = 220V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with Underwriter’s Recognition
W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)
(For additional details and options, see Section G - Clogging Indicators.)
F94
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 30
Weight (lbs.) 5.3
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DF 30 Z
B
P
A
B
A
A
P
T
P
B
T
T
311.22
1.0927.8
32.5
0.236
10.30.2095.3
4 Places
26.6
40.5
1.05
19 0.75
16.30.641.59
0.41
1.28
THRU
0.030.8
Indicator PortG 1/2"
0.4812.2
1.8948
0.37.6
1.0627
for element removal
[1.77] 45Clearance required
INLET Face
2208.66
0.24
6
1.8146
(Left Hand Version) - (optional)
D03 Pattern
(Right Hand Version) - (optional)
F95
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Size 60 110
Weight (lbs.) 13.1 15
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions DF 60 / 110 Z
P
TT
A B
P
TT
A B
P
BA
TT
[9.88]DF 110 Z
[12.63]321
DF 60 Z
251
HEX 1.0627
D05 Pattern
21.40.84
1.28 32.5
16.7 0.66
0.133.2
542.13
200.79
2
50.8
37.31.47
0.25
6.3
271.06
461.81
0.4712
Indicator PortG 1/2"
5 Places
0.6215.7
0.410.2
D05 Pattern
[3.15]80Clearance requiredfor element removal
0.26
6
68.2
Mounting through6.6Holes (4 Places)
702.76
0.24
2.69
Indicator PortG 1/2"
P
TT
A B
P
TT
A B
P
BA
TT
[9.88]DF 110 Z
[12.63]321
DF 60 Z
251
HEX 1.0627
D05 Pattern
21.40.84
1.28 32.5
16.7 0.66
0.133.2
542.13
200.79
2
50.8
37.31.47
0.25
6.3
271.06
461.81
0.4712
Indicator PortG 1/2"
5 Places
0.6215.7
0.410.2
D05 Pattern
[3.15]80Clearance requiredfor element removal
0.26
6
68.2
Mounting through6.6Holes (4 Places)
702.76
0.24
2.69
Indicator PortG 1/2"(Left Hand Side Version) - (optional)
D05 Pattern
(Right Hand Side Version) - (standard)
F96
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
60
50
40
30
20
10
Q in gpm
DFZ 30 Housing DFZ 60 / 110 Housing
6543210 7 20151050
80
60
40
20
Q in gpm
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x
Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86
Metal Fiber ...D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0030 D XXX V 1.011 0.740 0.411 0.2000060 D XXX V 0.877 0.511 0.296 0.1830110 D XXX V 0.452 0.304 0.182 0.118
Betamicron ...D…BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm
0030 D XXX BH4HC 5.005 2.782 1.992 1.0430060 D XXX BH4HC 3.216 1.789 0.993 0.6700110 D XXX BH4HC 1.394 0.818 0.489 0.307
All Element K Factors in psi / gpm.
F97
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Notes
F98
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Construction Industrial
Railways
CommercialMunicipal
Features• Made of aluminum for light weight and low cost.• Made to dispose of when fully clogged.• Low price - market competitive.
CF SeriesManifold Cartridge Filters3000 psi • up to 25 gpm
A
B
CFxx20 CFxx45
Technical SpecificationsPort Connections CF20
CF45SAE-16 Modified CavitySAE-20 Cavity (VC20-S3)
Direction of Flow Outside to Inside flowMaterials of Construction AluminumFlow CapacityCF20
CF45
5 GPM (15 micron - fiberglass media)2.5 GPM recommended design flow max. - for high efficiency media12 GPM (25, 149 micron - wire screen media)12 GPM (15 micron - fiberglass media)6 GPM recommended design flow max. - for high efficiency media25 GPM (25, 149 micron - wire screen media)
Housing Pressure RatingMax. Allowable Working Pressure:Proof Pressure:
3000 psi (207 bar)4500 psi (310 bar)
Element Performance RatingMM, W 290 psid (20 bar)
Fluid Temperature Range -22°F to 250°F (-30°C to 121°C)Consult HYDAC for applications operating below -22ºF (-30ºC)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
F99
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeCF W 20 G 25 W 1 . 0 / 12 .
Filter Type CF = Manifold Cartridge Filter
Element Media MM = Mobilemicron® W = Wire Mesh
Size 20, 45
Type of Connection G = Threaded
Filtration Rating (micron) 25, 149 = W 15 = MM
Type of Indicator W = No Indicator Available
Type Number 1 = Standard Configuration
Modification Number (latest version always supplied)
Port Configuration 12 = SAE-16 Modified Cavity (CF 20) 12 = SAE-20 Cavity (VC20-S3) (CF 45)
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
1.0
0.8
0.5
0.3
0.0
1.3
0 3 6 9 12 15
18.0
15.0
12.0
9.0
6.0
3.0
0.0
21.0
0 1 2 3 4
CFMM20G15W1.0/12Q in l/min
Q in gpm
1.0
0.8
0.5
0.3
0.0
1.3
0 10 20 30 40 50 60
18.0
15.0
12.0
9.0
6.0
3.0
0.0
21.0
0 3 6 9 12 15 18
CFW20G25/149W1.0/12Q in l/min
Q in gpm
1.0
0.8
0.5
0.3
0.0
1.3
0 5 10 15 20 25 30 35 40 45 50 55
18.0
15.0
12.0
9.0
6.0
3.0
0.0
21.0
0 3 6 9 12 15
CFMM45G15W1.0/12Q in l/min
Q in gpm
1.0
0.8
0.5
0.3
0.0
1.3
0 10 20 30 40 50 60 70 80 90 130120110100
18.0
15.0
12.0
9.0
6.0
3.0
0.0
21.0
0 5 10 15 20 25 30 35
CFW45G25/149W1.0/12Q in l/min
ΔP
in b
arΔ
P in
bar
ΔP
in b
ar
ΔP
in p
sid
ΔP
in p
sid
ΔP
in p
sid
ΔP
in p
sid
ΔP
in b
ar
Q in gpm
Pressure Drop Curves
F100
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Dimensions CFxx20
Size 20
Weight (lbs.) 0.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
572.24
of the Fitting
2.6066
Min Depth
35.5+ 0.10
1.398+-0.0040.000
15°
1.50" HEX
INLET
2.63
25.4
67
1.00
1-5/16-12UN-2A IN.
3.1680.2
Ra1
.6
A
A
0.05
Ra1.6
A
0.1
OUTLET
Ra1
.6
0.05A
Z
19
1-5/16-12UN-2B IN.
49Spot Face
From 30 to 41
R0.20.008
1.93
0.79 MIN20 MIN
68.5
25.5±0.1
0.8
19
2.70
1.003±0.002
0.03
Pilot Drill
0.75
0.75
[1.18] [1.64]
20°
DETAIL ZSCALE 1.5 : 1
Ra1
.6
0.008R0.2
0.13+-0.0120.000
3.3+ 0.30
45°±5°
F101
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Dimensions CFxx45
Size 45
Weight (lbs.) 0.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
66 2.598
1.713±0.00443.5±0.1
15°±1°
A
A
INLET
Z
0.1
OUTLET
0.05
Ra1
.6
A
Ra1.6
0.1A
X
2.283
1.313
SAE-20 PORT
MAX
1.187
3.059
0.79 MIN20 MIN
33.35
1 5/8"-12UN-2B IN.
2.293
58
77.7
0.031
+
0.8
0+0.000
-0.002
0.051
30.15
SPOTFACE58
1.0025.4
SCALE 1.5 : 1DETAIL Z
Ra1
.6
0.3 +
45°
0
0.134+-0.0120.000
3.4
0.008R0.2
SCALE 4 : 1DETAIL X
Ra1
.6
20°
0.008R0.2
2.0051 HEX
3.52
76.23.00
89.4
33.3
1.311
1-5/8"-12UN-2A IN.
From [1.497]
38 to
[1.969]50
F102
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction
Features• Simple cost effective method of component protection with
minimal space requirements, eliminating design restraints.• Fits into a standard manifold Cavity No. C16-2 Port.• CP Circuit Protector Filters provide backup protection when
upstream pressure filters go into bypass or if element damage occurs.
• Two (2) different element options: 10 micron, and 141 micron allow filter to be tailored to individual application needs.
• Suitable for petroleum based fluids.• Flow Path - inside to outside.
CP-C16 SeriesCircuit Protector Manifold Cartridge Filters3000 psi • up to 12 gpm
A
B
Technical SpecificationsMounting Method C16-2 Cavity (SAE-16 Threaded Port)Flow Direction Inlet: Bottom Outlet: SideConstruction Materials SteelFlow Capacity 12 gpm (45 lpm)Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
3000 psi (210 bar)Contact HYDAC OfficeContact HYDAC Office
Element Collapse Pressure RatingW/HC 250 psid (17 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility Compatible with all petroleum oils rated for use with Nitrile rubber (NBR) seals.
F103
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeCP-C16 W 40 G 10 W 1 . 0 / 12 .
Filter Type CP-C16 = Circuit Protector (Common Cavity No. C16-2)
Element Media W = Wire Mesh
Size 40 Inline Port G = 1” Male Thread 1 5/16-12UN-2A (SAE-16)
Filtration Rating (micron) 10 = 10 micron 141 = 141 micron
Bypass Indicator W = No indicator Port
Type Number 1 = Standard Configuration
Modification Number
Port Configuration 12
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
00
10
20
30
40
50
6010 µm
141 µm
4 8 12
Q in gpm
Pressure Drop Curves
Based on testing conducted with 150 SUS fluid at 105˚F.
F104
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Dimensions CP-C16
1.126+-0.0020.000
28.6+0.050
0.5313.5
1.844 MIN46.84 MIN
1.3434
0.7519
0.13 MAX3.2 MAX
0.14±0.0083.5±0.2
1.9349
1.4±0.00235.55±0.05
1-5/16-12UN-2B IN.
20°
1.2231
0.03R0.75
0.5313.5
0.9724.6
15°
[0.06]R1.5
1.6
0.002 A
0.05 A
[ ]
0.004 A
0.1 A
[ ]
0.008 A
0.2 A
[ ]
A
1.1228.52
2.2958.3
0.4912.5
1-5/16-12UN-2A IN.
1.538.1 HEX
Size 40
Weight (lbs.) 0.75
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Installation Torque:200 lb – ft into Steel Block
155 lb – ft into Aluminum Block
F105
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Notes
F106
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Hydraulic Symbol
Applications
Agricultural Automotive Construction
Features• Simple cost effective way to provide component protection with
minimal space required eliminating design restraints.• Fits into a standard manifold SAE O-ring Port.• CP Circuit Protector Filters provide backup protection when
upstream pressure filters go into bypass or if element damage occurs.
• CP-SAE provides operations protection through supply of a bypass to assure flow to critical components if filter becomes clogged.
• Increased range of product use through three (3) different sizes available, 15 at 4 gpm, 40 at 12 gpm, and size 120 at 30 gpm.
• Suitable for petroleum based fluids.• Flow Path - inside to outside.
CP-SAE SeriesCircuit Protector Manifold Cartridge Filters6090 psi • up to 30 gpm
B
A
Technical SpecificationsMounting MethodCP-SAE-15CP-SAE-40CP-SAE-120
SAE-10 Port (5/8”)SAE-16 Port (1”)SAE-24 Port (1 1/2”)
Flow Direction Inlet: Bottom Outlet: SideConstruction MaterialsCP-SAE-15CP-SAE-40CP-SAE-120
Carbon steel Carbon steel Stainless steel
Flow CapacityCP-SAE-15CP-SAE-40CP-SAE-120
4 gpm (15 lpm)12 gpm (45 lpm)30 gpm (113 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
6090 psi (420 bar)Contact HYDAC OfficeContact HYDAC Office
Element Collapse Pressure RatingW 100 psid (6.9 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)
Fluid Compatibility Compatible with all petroleum oils rated for use with Nitrile rubber (NBR) seals.
Bypass Valve Cracking Pressure∆P = 50 psid (3.4 bar) +10% (standard)
Replacement ElementsPart Number Description Flow Rate
02069397 0015 D 010 W 0015 - 4 gpm02069398 0040 D 010 W 0040 - 12 gpm02069399 0120 D 010 W 0120 - 30 gpm
F107
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model CodeCP-SAE W 15 G 10 W 1 . 0 / 12 B3.5 .
Filter Type CP-SAE = Circuit Protector (SAE O-ring Port)
Element Media W = Wire Mesh
Size 15 = 4 gpm 40 = 12 gpm 120 = 30 gpm
Inline Port G = Male Threaded
Filtration Rating (micron) 10 = 10 micron 75 = 75 micron 149 = 149 micron
Bypass Indicator W = No indicator Port
Type Number 1 = Standard Configuration
Modification Number
Port Configuration 12 Bypass Valve B3.5 = 50 psi
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Pressure Drop CurvesBased on testing conducted with 150 SUS fluid at 105˚F.
00
10
20
30
40
50
0
75/141 µm
0.68
2.06
3.44
10 µm
2 4 6 8 10
0 7.57 20.8 33.1
Q (gpm)
CP-SAE 15
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
00
10
50
20
30
40
0
75/141 µm
0.68
10 µm
2.06
3.44
5 10 15 20
0 18.9 37.8 56.7 75.6
Q (gpm)
CP-SAE 40
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
00
10
20
30
40
50
0
0.68
2.06
75/141 µm
10 µm
3.44
10 20 30 40
0 37.8 75.6 113.4 151.2
Q (gpm)
CP-SAE 120
ΔP
in p
si
ΔP
in b
ar
Q (l/min)
15 = 5/8” SAE 10 Port-Threaded40 = 1” SAE 16 Port-Threaded120 = 1 1/2” SAE 24 Port-Threaded
F108
HIGH PRESSURE FILTERS
PN#02081318 / 03.16 / FIL1505-1696
Model A B C D E SAE O-Ring Port F G H J
TorqueAlu. Steel
CP-SAE 15 1.00/25.4 0.41/10.4 1.75/44.5 0.74/18.8 -10 (7/8-14) 2.41/61.2 1.12/28.4 min 1.87/47.5 max 0.266/6.8 0.781/19.8 min
0.814/20.7 max65
ft-lb85
ft-lb
CP-SAE 40 1.5/38.1 0.5/12.7 2.50/63.5 1.00/25.4 -16 (1 5/16-12) 3.34/84.8 1.49/37.8 min 2.53/64.3 max 0.531/13.5 1.140/29.0 min
1.1875/30.1 max150 ft-lb
200 ft-lb
CP-SAE 120 2.13/54.1 0.65/16.5 4.00/101.6 1.50/38.1 -24 (1 7/8-12) 5.01/127.3 1.92/48.8 min 3.81/96.8 max 0.875/22.2 1.750/44.5 min
1.803/45.8 max230 ft-lb
305 ft-lb
Dimensions CP-SAE
G
F
H
H
J0.030 Max Radius0.076Or Chamfer
Manifold FilterCavity Configuration
F
B
A
A
A
C
DOUTLET PORT
FilterElement (10 MicronWire Cloth Standard)
50 P.S.I.D.Bypass Valve(Initial Cracking)
BypassValve Assembly
INLET PORT
Size 15, 40, 120
Weight (lbs.) 1.5
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.