Dirk India Private Limited Ambuja HiRise Test No. Test Unit Typical Test Results Chemical Requirements 1 Loss on Ignition, max % 5 0.76 2 Magneisa, max % 6 2.52 3 Sulphuric Anhydride, max % 3 1.68 % X + 4.0 (100 - X) 100 X = declared % of fly ash 5 Chloride, max % 0.1 0.01 Physical Requirements 1 Fineness , min m2/kg 300 366.20 2 Normal Consistency % 31.20 3 Setting Time a. Initial, min minutes 30 115 b. Final, max 600 225 4 Soundness a. Le- Chatelier Expansion, max mm 10 1.00 b. Autoclave Expansion, max % 0.8 0.03 5 Compressive strength % 0.73 a. 72 +/- 1 hr Mpa 16 33.90 b. 168 +/- 2hr MPa 22 46.10 c. 672 +/- 4hr MPa 33 62.80 6 Drying shrinkage, max % 0.15 0.08 A.R.Yadav Q.C.Department Regd Office:10,India House,Geetanjali Colony,Indira Nagar,Nashik-422009 Phone:(0253) 2322816, 2326679 Fax:(0253) 2326678 32.9 Insoluble material, max 4 Ambuja HiRise Cement Specimen Test Certificate Factory:Gut No 348, Behind NTPS, Eklahare, Nashik-422105 www.ambujahirise.in IS 1489 (Part1): 1991 requirements

Upload: dirkmedia

Post on 02-Mar-2016

216 views

Category:

Documents


0 download

DESCRIPTION

HiRise Specimen Test Certificate

TRANSCRIPT

Page 1: HiRise Specimen Test Certificate

Dirk India Private Limited

Ambuja HiRise

Test

No.

Test Unit Typical Test

Results

Chemical Requirements

1 Loss on Ignition, max % 5 0.76

2 Magneisa, max % 6 2.52

3 Sulphuric Anhydride, max % 3 1.68

% X + 4.0 (100 - X)

100

X = declared % of

fly ash

5 Chloride, max % 0.1 0.01

Physical Requirements

1 Fineness , min m2/kg 300 366.20

2 Normal Consistency % 31.20

3 Setting Time

a. Initial, min minutes 30 115

b. Final, max 600 225

4 Soundness

a. Le- Chatelier Expansion, max mm 10 1.00

b. Autoclave Expansion, max % 0.8 0.03

5 Compressive strength % 0.73

a. 72 +/- 1 hr Mpa 16 33.90

b. 168 +/- 2hr MPa 22 46.10

c. 672 +/- 4hr MPa 33 62.80

6 Drying shrinkage, max % 0.15 0.08

A.R.Yadav Q.C.Department

Regd Office:10,India House,Geetanjali Colony,Indira Nagar,Nashik-422009

Phone:(0253) 2322816, 2326679 Fax:(0253) 2326678

32.9Insoluble material, max4

Ambuja HiRise Cement

Specimen Test Certificate

Factory:Gut No 348, Behind NTPS, Eklahare, Nashik-422105

www.ambujahirise.in

IS 1489 (Part1):

1991