© 2014 IBM Corporation HMC, vHMC, Live Partition Mobility Luc Cloutier [email protected] Frédéric Marcil [email protected] Charts from : Linda Flanders, IBM USA SSE Delivery and Development Program Manager Gareth Coates, IBM UK EMEA Technical Lead and Product Introduction: Power Systems S. Ashok, IBM Austin Cognitive Systems Management

Upload: others

Post on 19-Mar-2020

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

© 2014 IBM Corporation

HMC, vHMC, Live Partition Mobility

Luc [email protected]

Frédéric [email protected]

Charts from :

Linda Flanders, IBM USA

SSE Delivery and Development Program Manager

Gareth Coates, IBM UK

EMEA Technical Lead and Product Introduction: Power

Systems

S. Ashok, IBM Austin

Cognitive Systems Management

Page 2: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Contents

Part I : HMC/vHMC/Enhanced GUI

PART II : Live Partition Mobility

2

Page 3: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Introduction

• Do you use an HMC?

• Lots of them?

• Many sessions about HMCs and how to do things with them

• Reflects on some of the options

– EG: when to use physical or virtual

3

Page 4: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

What is the HMC for?

• Control/manage/monitor POWER Servers

• Deploy power servers

• Deploy LPARs

• Deploy VIOS

• DHCP for FSP

• Callhome

4

Page 5: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

What hardware should I use?

• Intel based 7042-CR9

• Power based 7063-CR1

• Virtualised Intel server

• Virtualised POWER8 server

– If so, where/on what?

• You can probably guess what we will advise, but let’s look at it …..

5

Page 6: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

6

7042-CR9 HMC Details

▪ For POWER6 and later servers

▪ 7042-CR9 --- follow-on to 7042-CR8

▪ Normal technology refresh

▪ Similar price to CR8

▪ Refreshed rack-mounted HMC– 2.4GHz Intel Xeon Processor

– 16GB to 192GB memory (#EM20 16GB feature code) – Most clients expected to use 16GB or 32GB for HMC

– One or optionally two 500GB SATA disk drives– Second drive allows RAID1 mirroring protection (recommended/defaulted)

– Support any two of the eight physical hot-plug SFF bays (max 2 supported)

– DVD-RAM

– Four integrated Ethernet ports

– Six USB ports

– One PCIe slot

– One or two power supplies (two recommended for hot-plug redundancy)

– 1U (1 EIA)

– Like CR8, does not offer an internal or external modem (or support one)

▪ HMC code level 8.4.0 or later

▪ 1U (1EA) rails included with CR9 (no separate feature code)

Page 7: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

HMC 7063-CR1 GA 4Q2017

▪ 7063-CR1 is based on System S821LC▪ Fixed Config

▪ 6 POWER8 cores with SMT8

▪ 32GB RAM

▪ 2 HDD

▪ Fits round holes and square holes

▪ Simple to install, remotely start/stop using BMC + ipmitool + web UI

▪ GA with HMC V8.870: 4Q 2017

Massive

concurrency

7063-CR1 has a lower list

price than 7042-CR9

7

Page 8: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

8

HMC Virtual Appliance Details .

▪ IBM Virtual HMC Complete Software offering – License plus software maintenance– PID – 5765-HMV– Approximately $4k CDN including 1 year SW maint

▪ Virtual HMC Runs – On x86 Hardware (provided by client)– x86 64-bit with Intel VT-x or AMD-V– 4 CPU, 8 GB memory, 160GB disk (500GB recommended), 2 NIC– Under KVM or VMware virtualization (provided by client)

▪ New vHMC Complete Software offering – Activation engine – provides configuration on first boot– Accept License, locale, network, SSH, NTP

▪ Manages any POWER6 or later Power servers▪ Version 8 HMC firmware▪ Can be used with or without hardware HMCs

Page 9: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

POWER8 virtual HMC

• POWER8 virtual HMC – like the Intel vHMC

• Runs in a PowerVM LPAR on a POWER8 server

– No, it will not run on a POWER7 processor

– Yes, it will manage a POWER7 based server

• Obviously, you can’t manage the server its actually running on!

• Note: not KVM, XEN, Vmware

9

Page 10: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Can I use both Intel and POWER8 HMCs

• YES

• A server can be managed by 2 HMCs

• Any combination of Intel/POWER

• Any combination of hardware appliance/software appliance

• Do not think about using a vHMC in a PowerVM LPAR on a server which

the HMC manages

• Allowed this time only one HMC at 860 + one HMC at 870

– Normally both HMC must be at exactly the same level

10

Page 11: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

HMC V8R870

• No Classic GUI

• Enhanced+ GUI has all functionality that was in Classic

• Runs on Intel or POWER8

• Manages

– POWER6

– POWER7

– POWER8

• HMC V8 will not manage POWER9 based servers

– So use the Enhanced+ GUI now

11

Page 12: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

I want to use the Classic GUI

• You can

– But only up to HMC V8 R860

– Support continues till end of 2018

– Then the only supported GUI will be Enhanced+

– HMC V8 will not manage POWER9 based servers

12

Page 13: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Classic vs Enhanced – Terminology & Menus

HMC Classic Interface HMC Enhanced UI Interface

Create Partition Templates (Resources > All Systems > Server > View System Properties > System Actions > Templates)

Partition Properties, DLPAR Manage Partition (Resources > All Systems > Server > Partition > * (Properties/Processors/Memory/Physical IO/Virtual Storage/Virtual Networks/Virtual NICs)

Server > Configuration > Virtual Resources Resources > All Systems > Server > PowerVM

Server > Hardware Information > Adapters Resources > All Systems > Server > PowerVM > Hardware Virtualized I/O

Server > Performance Resources > All Systems > Server > View System Properties > Capacity > Performance Dashboard

Server > Properties Resources > All Systems > Server > View System Properties

Partition > Configuration > Manage Profiles Resources > All Systems > Server > Partition > Partition Actions > Profiles

13

Page 14: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Navigating through Enhanced UI – Launch Page – Gallery View

Tool Bar

Resource Path

Quick Filter (Filter by fields of specific resource)

Global Search (Search across all resources)

Pins – Like Shortcuts/Bookmarks

Task Log

Gallery, Table & Relational Views

Pin the page

14

Page 15: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Navigating through Enhanced UI

My counterpart in the UK, Nigel Griffiths, has done a really nice job covering this in a 10 part series. https://www.youtube.com/user/nigelargriffiths

15

Page 16: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

• PART II Live Partition Mobility

16

Page 17: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

LPM Benefits

• Simplify server upgrades with no down time

- Move running partitions to newer servers

• Better system utilization

- Quickly balance workloads and resources as needs change

• Improved application availability

- Eliminate downtime for planned system maintenance

• Energy savings

- Consolidate workloads to fewer servers when possible and turn off idle systems

While LPM improves system availability, it is not a solution for unplanned outages.

Continue using high availability solutions.

17

Page 18: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

18

PowerVM™ Live Partition Mobility

PowerVM™

Hypervisor

What is LPM?▪Relocate an entire LPAR

between physical chassis

▪Requires POWER6™ or

better

▪LPARs continue to run and

provide services to clients,

who are completely unaware

of the migration

▪Final suspension and

resumption of LPAR is

guaranteed to be less than 2

seconds

AIX VIOS

PowerVM™

Hypervisor

IBM iVIOS Red

Hat

Linux

4GB 4GB 4GB 4GB

Red

Hat

Linux

4GB

192.9.200.1

Ethernet

StorageStorage

Page 19: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Migration: active or inactive

Active migration: partition migration is performed with the operating system and applications running, without disrupting operations

Inactive migration: partition is not running when it is moved to the target system

Active

• Validate configuration• Create new LPAR• Create new virtual resources• Migrate state of LPAR in memory• Remove old LPAR configuration• Free up old resources

Inactive

• Validate configuration• Create new LPAR• Create new virtual resources• Remove old LPAR configuration• Free up old resources

Summary of Migration Phases

19

Page 20: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Mobile partition requirements checklist (1 of 2)

Check mobile partition configuration:

✓ Operating system support

✓ Functioning RMC daemons

✓ No huge memory pages*

✓ No Barrier Synchronization Register arrays* (BSR)

✓ No workload group

✓ No redundant error reporting*

✓ No open consoles (warning only)

✓ Storage on external storage unit and accessible by both VIOS LPARs

✓ Check that LPAR name will be unique on destination server

* Okay for inactive migrations

20

Page 21: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Mobile partition requirements checklist (2 of 2)

Check mobile partition configuration (cont.):

✓ Check MAC address will be unique on destination server

✓ Not a service partition

✓ No physical I/O*

✓ No logical ports configuration on Integrated Virtual Ethernet (IVE)/Host Ethernet Adapter or SR-IOV (unless using vNIC)

– AIX 6100-05 (or higher) clients can convert LHEA to virtual Ethernet during migration

✓ Verify valid processor compatibility mode

✓ Virtual network configuration compatible with destination VIOS

* Okay for inactive migrations

21

Page 22: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Client operating system support

Minimum supported AIX partition operating systems:

– AIX 5.3 TL07

– AIX 6.1 TL02 with SP08

Minimum supported Linux partition operating systems:

– Red Hat Enterprise Linux version 5 Update 1

– SUSE Linux Enterprise Server 10 Service Pack 1

– Linux operating systems must install RPMs for DLPAR

Minimum supported IBM i:

– IBM i version IBM i 7.1 TR4 or higher

– HMC version 7 release 7.5 or higher or FSM

– Server firmware levels: 730_51 or later, 740_40 or later

– VIOS 2.2.1.4

22

Page 23: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Physical I/O

Partition properties should show no physical I/O adapters

ClassicExample

Enh+ Example

Nothing to see here

23

Page 24: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

LPM migration operation (1 of 2)

Run either the Migrate task (Wizard) or Validate task (one panel):

For HMC Classic GUI, select partition and run Operations -> Mobility -> Migrate (or Validate)

HMC Enhanced+ Example

24

Page 25: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

LPM migration operation (2 of 2)

Validate task provides one panel validation and

migration

New Redundant MSP option if using newer code

25

Page 26: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

PowerVM LPM and Simplified Remote Restart Automation Tool (1 of 3)

IBM Lab Services GUI for managing migrations

– POWER7 and POWER8 migrations

– Linux, AIX, and Windows versions

– Browser-based with reduced clicks!

The tool version numbering now matches the features of the highest HMC version it can exploit

– In use since 2014

Download from Resource Link, unzip, add your HMC, and it discovers your servers and LPARs

– Need to contract with Lab Services

Uses SSH to direct HMCs to do migrations

26

Page 27: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

PowerVM LPM and Simplified Remote Restart Automation Tool (2 of 3)

LPM tool features:

– Evacuate a server to one or multiple servers

– Move groups of partitions

– Can “Pack” or “Stripe” LPARs to destination servers

– Maintain concept of “original” server for mobile partitions

– Create migration plans and deploy plans during service windows

– Export validation details to a spreadsheet

– Many GUI features only available on HMC command line: vSwitch, vNIC, NPIV LUN validation, SR-IOV, concurrency levels, etc.

• Easy to maintain virtual adapter IDs and FC port ID assignments

SRR tool features:

– In case of server outage, restart its LPARs on a remote server

– Configuration details of the LPAR is kept on disk to quickly get it running on remote server

– After downed server is up and running, a few clicks will get original LPARs migrated back with LPM

– Without automation tool, SRR is available only on HMC CLI 27

Page 28: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

PowerVM LPM and Simplified Remote Restart Automation Tool (3 of 3)

Eight migrating LPARs in progressLPARS

Use tool’s config.properties file for specific instructions- Example line that adds --requirerr 2 to migrlpar :com.ibm.lbs.asset.hmc850.migrlpar.append.minus.minus.requirerr 2

28

Page 29: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

LPM Resources

Take the full three day LPM Course:

– IBM customer training course via training partners AN33G: www.ibm.com/training

– IBMers and BPs with education vouchers: //ibm.biz/ibm-sse

– IBM Lab Services consulting and custom training

Redbooks and Hardware Information Center:

– IBM PowerVM Live Partition Mobility SG24-7460

– IBM PowerVM Virtualization Managing and Monitoring SG24-7590

LPM user guide includes IBM i information: http://pic.dhe.ibm.com/infocenter/powersys/v3r1m5/topic/p7hc3/p7hc3.pdf

Developerworks movie: tinyurl.com/newAIXmovies

29

Page 30: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Merci!

Pour plus de renseignements ou pour planifierune rencontre,

contactez l’équipe R2i.

www.r2i.ca

[email protected]

1 844 312-3007, poste 100

Page 31: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Notices and disclaimers

© 2018 International Business Machines Corporation. No part of this document may be reproduced or transmitted in any form without written permission from IBM.

U.S. Government Users Restricted Rights — use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM.

Information in these presentations (including information relating to products that have not yet been announced by IBM) has been reviewed for accuracy as of the date of initial publication and could include unintentional technical or typographical errors. IBM shall have no responsibility to update this information. This document is distributed “as is” without any warranty, either express or implied. In no event, shall IBM be liable for any damage arising from the use of this information, including but not limited to, loss of data, business interruption, loss of profit or loss of opportunity. IBM products and services are warranted per the terms and conditions of the agreements under which they are provided.

IBM products are manufactured from new parts or new and used parts. In some cases, a product may not be new and may have been previously installed. Regardless, our warranty terms apply.”

Any statements regarding IBM's future direction, intent or product plans are subject to change or withdrawal without notice.

Performance data contained herein was generally obtained in a controlled, isolated environments. Customer examples are presented as illustrations of how those

customers have used IBM products and the results they may have achieved. Actual performance, cost, savings or other results in other operating environments may vary.

References in this document to IBM products, programs, or services does not imply that IBM intends to make such products, programs or services available in all countries in which IBM operates or does business.

Workshops, sessions and associated materials may have been prepared by independent session speakers, and do not necessarily reflect the views of IBM. All materials and discussions are provided for informational purposes only, and are neither intended to, nor shall constitute legal or other guidance or advice to any individual participant or their specific situation.

It is the customer’s responsibility to insure its own compliance with legal requirements and to obtain advice of competent legal counsel as to the identification and interpretation of any relevant laws and regulatory requirements that may affect the customer’s business and any actions the customer may need to take to comply with such laws. IBM does not provide legal advice or represent or warrant that its services or products will ensure that the customer follows any law.

31

Page 32: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

Notices and disclaimerscontinued

Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products about this publication and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. IBM does not warrant the quality of any third-party products, or the ability of any such third-party products to interoperate with IBM’s products. IBM expressly disclaims all warranties, expressed or implied, including but not limited to, the implied warranties of merchantability and fitness for a purpose.

The provision of the information contained herein is not intended to, and does not, grant any right or license under any IBM patents, copyrights, trademarks or other intellectual property right.

IBM, the IBM logo, ibm.com and [names of other referenced IBM products and services used in the presentation] are trademarks of International Business Machines Corporation, registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at: www.ibm.com/legal/copytrade.shtml.

.

32

Page 33: HMC, vHMC, Live Partition Mobility...HMC, vHMC, Live Partition Mobility Luc Cloutier luc@ca.ibm.com Frédéric Marcil Frederic.marcil@r2i.ca Charts from : Linda Flanders, IBM USA SSE

33