prismalume · holophane holophane research & development center newark, ohio 43055 distribution...
TRANSCRIPT
Prismalume luminaires are theperfect fixtures for a variety of heavy-duty high bay applications includingindustrial, commercial and educa-tional facilities.
Prismalume luminaires are availablein a choice of six rugged prismaticglass reflectors, efficiently controllinglight for exceptional visibility.
Available in a wide range of HIDlamps and ballasts, Prismalumeluminaires deliver required lightinglevels in an energy efficient manner.
Robust design characterizesPrismalume luminaires, fromcorrosion resistant materials andcoatings to long lasting borosilicateprismatic glass reflectors.
Prismalume luminaires feature tool-less mechanisms and open glassoptics that simplify installation andoptimize maintenance.
PRISMALUME®
HL-755 8/02
2
PRISMALUME®
HOLOPHANE®
• Choice of factory set distributions
• Thermal shock resistant prismatic glass reflectors
• Thermoset white polyester powder paint
• Die cast aluminum ballast housing
• UL/CUL listed
Gyms and field houses
Gymnasiums, swimming pools,field houses and multi-purposerooms demand a multi-purposelighting system. Basketball, vol-leyball and tennis require a totallyilluminated environment. Uniformvertical illumination is equally im-portant as illumination on theplaying surface.
Industrial
Machinery and other manufactur-ing equipment along with the sur-rounding area all interact with theworker’s ability to see and pro-duce products efficiently, safelyand to exacting standards. Thevalue provided by Prismalumereflectors is the result of a precisecombination of horizontal andvertical footcandles. This bal-anced illumination improves theability to see and provides anoverall level of visual comfort.
The engineered combination ofuplight and downlight providessuperior vertical illumination for awide variety of applications in-cluding warehouse aisle lighting.
PRISMALUME®
3 HOLOPHANE®
INDUSTRIAL HIGH BAYS
RETAIL STORES
GYMNASIUMS
ASSEMBLY AREAS
WAREHOUSES
CONVENTION CENTERS
Retail
The merchandising objective is tocreate environments that positivelyinfluence the buying decision.
Visually appealing, efficient illumin-ation from a Prismalume luminaireis the optimum lighting choice.
Prismalume luminaires provideuniform illumination where goodsare displayed on horizontal tablesand fixtures. Gondolas now rangefrom 2.13m (7’) in grocery areas to6.10m (20’) in newer warehousestyle stores. Such vertically displayedmerchandise is more visible underPrismalume’s prismatic glassreflectors. Interior store signage isbrightly illuminated by the upwardcomponent of light fromPrismalume luminaires.
Efficient lighting of thevisual environment
Prismalume reflectors providemaximum efficiency for flexibilityof design. The unique prismaticglass reflector system coupledwith a wide selection of HIDlamps and wattages means anextensive choice of distributionsare available to tailor yourlighting design to the application.
The unique balance of uplightand downlight from Prismalumeluminaires provides outstandinglighting solutions for countlessapplications.
4
PRISMALUME®
HOLOPHANE®
1 Zinc plated steel yoke:Quickly secures reflector to housingfor long life and easy installation.
2 Open top for self-cleaning:Reduces need for constantmaintenance.
3 Non-adjustable easilyinstalled dual actionsuspension lugs: Properlypositions and locks reflector in placefor designed photometrics.
4 Open prismatic borosili-cate glass reflector: Lowelectro-static charge minimizes dirtbuild-up.
5 Zinc plated steel rods andrings: Supports and protects glassreflector.
Prismatic glass reflectors
• Proven performance for over100 years.
• Choice of six highly efficientreflectors.
• Provides an excellent balanceof horizontal and verticalillumination.
• Prismatic glass reflectorsminimize brightness from innersurface.
• Glass reflectors will not pit orcorrode in normal industrial use.
• Endural® borosilicate glassreflectors resist thermal shock andare designed to withstand theheat generated by efficient HIDlamps.
123
4
5
Highly efficient luminaires
The overall efficient performanceof Prismalume luminaires canresult in fewer fixtures providingthe designed illumination levels.Fewer fixtures reduce installationand operating costs.
Unlike aluminum or plastic reflec-tors, borosilicate glass reflectorsare not subject to permanent de-terioration caused by industrialenvironments and do not presentthe additional safety concerns ofplastic reflectors.
PRISMALUME®
5 HOLOPHANE®
400-1000W ballast shown
150-400W ballast shown
Rugged ballast assembly
• Die cast aluminum housingcombines corrosion resistancewith mechanical strength for therugged industrial environment.
• Mounting plate spins onto.75” NPT conduit and providessecure attachment for the slideon housing while the wirewaycover encloses the wiringchamber and secures housing tothe conduit.
• Seven stage pretreating of thehousing is followed by a sprayedon polyester powder paint, curedand baked on at 218°C. Thisexceeds ASTM standard practicefor hardness, humidity, impactand salt spray resistance toprevent cross hatch creep,fading, cracking, and otherweather related deterioration.
• Pre-wired, porcelain enclosedsocket with corrosion resistant,nickel plated lamp grip screwshell, is attached to the housingto provide specified lightingdistribution from a choice ofglass reflectors.
• UL listed 1598 55°C damplocation as standard, with op-tional 65°C listing available.
• Balanced mounting frommalleable cast iron hooks andloops without field adjustment.
• High power factor (over 90%)copper wound ballast is testedand matched with capacitors toprovide full lamp wattage atlower energy consumption.Ballast and capacitor are heatsunk for cool operation and longlife. Holophane ballasts ensurerated lamp output (ballast factor= 1.0)
• Easy attachment of reflector tohousing is provided by lockinglugs which prevent accidentaldislodging of the reflector.
• Optional quick disconnect orthroughway wiring chamberquickly spins onto .75” NPTconduit or can be ceiling mount-ed. Integral hinge supports forhands-free wiring. UL/CUL listed.Throughway box can carry up tofive #10 wires with 24 amps perwire.
“31”
“35”“37” “39”
“40” “50”
PRISMALUME®
7 HOLOPHANE®
A choice of light distributions
Reflector catalog number matrix
High Pressure Sodium - Lamp source and wattageSpacing to 150HP 150HP 250HP 250HP 400HP 400HP 400RHP 400RHP 750HP 1000CHP 1000HPmtg. ht. ratio Clear Diffuse Clear Diffuse Clear Diffuse Clear Diffuse Clear Clear Clear0.7:1 Z400.8:1 B390.9:1 N39 M39 J39 Z391.0:1 S401.1:1 N39/S40 Z31 S40 U401.2:1 M35 M35 M35 M39 J39 H401.3:1 Q40 J39/L501.4:1 J31 T50 R50 Q50 W391.5:1 H31 M37 G351.6:1 H31 Z31/M35 M35 J35 S39 L391.7:1 N31 S40 P31 U40 C35/H391.8:1 J31 N31/M35 P31/R50 N311.8:1 T50 J351.9:1 M37 M37 J37 M352.0:1 H31 H31/M37 L31 L31/J37 V502.2:1 U39
Metal Halide - Lamp source and wattageSpacing to 250MP/250PPmtg. ht. ratio 25LMP/25LPP 350PM/35LPM
175MP 320PP 400PM/40LPM 400MH 400MH 400SMH 400SMH 400RMH 400RMH 750PM 1000MH 1000MHClear Clear Clear Clear Coated Clear Coated Clear Coated Clear Clear Coated
0.7:1 E40 M400.8:1 E40 E40 E40 M400.9:1 E40 Z40 B501.0:1 L40 G39 Z39 B40/B501.1:1 B35 B35 B35 B35/G39 B35 Y31/L50 Y35 B40 B39
H50 Z391.2:1 M35 M35 H50 G39/H50 G39 H50 L50 Z39 Y50 Y501.3:1 L39 H50 E31/B37 M31/Y37 N39
M39 J39 T501.4:1 B37/M39 M39 J391.5:1 J31/M37 J31/M37 B37 B37/M39 E31 N39 P39 C31/E351.6:1 E31 E31 N39 E31/B37 M31/Y37 B391.8:1 N39 N39 N39 P39
8
PRISMALUME®
HOLOPHANE®
Photometric Data — High Pressure Sodium
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
TOTALEFFIC.
OUTPUT DATA
60°60°
90° 90°
120° 120°180°150° 150°
39518
2500 CD/DIV
0 .98 .98 .98 .81 .81 .81 .701 .86 .83 .80 .71 .69 .68 .592 .76 .71 .67 .64 .61 .58 .513 .68 .62 .57 .57 .53 .50 .444 .61 .54 .49 .51 .47 .43 .385 .54 .48 .43 .46 .42 .38 .346 .49 .42 .37 .42 .37 .34 .307 .45 .38 .33 .38 .33 .30 .268 .41 .34 .29 .35 .30 .27 .239 .37 .31 .26 .32 .27 .24 .21 .34 .28 .23 .30 .25 .21 .19
ZONALDEGREES
TEST OF HOLOPHANE PRSL400HPXXPDM35
POSITION OF LAMP Set Position
LAMP 400W Clear HPS LUMENS 50000
WATTS 400 BULB TYPE E-18
TEST DISTANCE 25 ft S.C. = 1.6
TESTED BY
TEST NO.
pfcpccpw
20%70% 30%50% 30% 10% 50% 30% 10% 0%
RC
R
0°30° 30°
0 98035 9567 913
10 974815 10232 290020 10786
25 12005 555730 1473835 16216 1018740 1418545 10251 7939
50 624655 3342 299865 1344 133470 1419
75 1444 152880 150385 1511 164890 150195 1604 1750
105 2008 2124115 2125 2109125 1939 1740135 1457 1128145 1231 773
155 906 419165 159 45175 167 16180 207
0-30 9370 18.730-60 21124 42.260-90 4510 9.0
0-90 35004 70.090-180 10105 20.20-180 45109 90.2
CERTIFIED BY
10
20%70% 30%50% 30% 10% 50% 30% 10% 0%
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
ZONALDEGREES
TOTALEFFIC.
OUTPUT DATATEST OF HOLOPHANE PRSL400HP00XXN31
POSITION OF LAMP Set Position
LAMP 400W Clear HPS LUMENS 50000
WATTS 400 BULB TYPE E-18
TEST DISTANCE 25 ft S.C. = 1.7
TESTED BY CERTIFIED BY
TEST NO.
pfc
pccpw
RC
R
0 .98 .98 .98 .82 .82 .82 .721 .85 .81 .78 .71 .69 .67 .592 .74 .69 .64 .63 .59 .56 .493 .65 .59 .54 .55 .51 .47 .424 .58 .51 .45 .49 .44 .41 .365 .52 .44 .39 .44 .39 .35 .316 .46 .39 .34 .40 .35 .31 .277 .42 .35 .30 .36 .31 .27 .238 .38 .31 .26 .33 .28 .24 .219 .34 .28 .23 .30 .25 .21 .18
.32 .25 .21 .28 .22 .19 .16
0°30° 30°
60°60°
90° 90°
120° 120°180°150° 150° 0 91225 9321 890
10 908415 9357 265220 9330
25 9636 446030 1084235 12450 782140 1306445 11226 8694
50 814055 5507 494060 364065 2570 255170 2157
75 1892 200180 178485 1669 182190 148395 1526 1665
105 1601 1694115 1594 1582125 1453 1303135 1365 1057145 1395 877
155 1059 490165 305 86175 236 22180 167
0-30 8002 16.030-60 21455 42.960-90 6373 12.7
0-90 35831 71.790-180 8777 17.60-180 44607 89.2
40964
2000 CD/DIV
10
0 1.00 1.00 1.00 .84 .84 .84 .731 .85 .81 .78 .72 .69 .67 .592 .74 .68 .63 .62 .58 .55 .483 .64 .57 .52 .54 .49 .45 .404 .56 .49 .43 .48 .42 .38 .335 .50 .42 .36 .42 .37 .32 .286 .44 .36 .31 .38 .32 .28 .247 .40 .32 .27 .34 .28 .24 .208 .36 .28 .23 .30 .25 .21 .189 .32 .25 .20 .28 .22 .18 .1510 .29 .23 .18 .25 .20 .16 .13
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
ZONALDEGREES
TOTALEFFIC.
OUTPUT DATATEST OF HOLOPHANE PRSL400HPXXH31
POSITION OF LAMP Set Position
LAMP 400W Clear HPS LUMENS 50,000
WATTS 400 BULB TYPE E-18
TEST DISTANCE 25 ft S.C. 2.0
TESTED BY
TEST NO.
pfcpccpw
RC
R
0°30° 30°
60°60°
90° 90°
120° 120°180°150° 150°
40948
2000 CD/DIV
CERTIFIED BY
20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%
5576 5828 5704 6258 6913
7698 8893106321247112277
10139 7185 5115 3525 2696
2353 2117 1941 1744 1686
1648 1656 1461 1229 1110
987 281 227 163
556
1774
3563
6679
9508
6446
3499
2490
2117
1839
174416431311951698
457 80 22
589322633 810636632 874445376
11.845.316.273.317.590.8
0 5101520
2530354045
5055606570
7580859095
105115125135145
155165175180
0-30 30-60 60-90 0-9090-180 0-180
20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
ZONALDEGREES
TOTALEFFIC.
O U T P U T D ATATEST OF HOLOPHANE PRSL400HPXXPDS40
POSITION OF LAMP Set Position
LAMP 400W Clear HPS LUMENS 50000
WATTS 400 BULB TYPE E-18
TEST DISTANCE 25 ft S.C. = 1.1
TESTED BY CERTIFIED BY
TEST NO.
pfcpccpw
RC
R
0 .99 .99 .99 .80 .80 .80 .691 .85 .82 .79 .70 .68 .66 .562 .76 .70 .66 .62 .59 .56 .483 .68 .61 .56 .56 .52 .49 .424 .61 .54 .49 .51 .46 .43 .375 .55 .48 .43 .46 .42 .38 .336 .50 .43 .38 .43 .38 .34 .307 .46 .39 .34 .39 .35 .31 .278 .42 .36 .31 .36 .32 .28 .259 .39 .33 .28 .34 .29 .26 .23
.36 .30 .26 .32 .27 .24 .21
0°30° 30°
60°60°
90° 90°
120° 120°180°150° 150° 0 156505 14178 1353
10 1521615 17386 492820 16879
25 16089 744730 1362435 10451 656540 685445 4805 3721
50 452955 4406 395260 314265 1903 188970 1599
75 1975 208980 227185 2440 266290 229695 2171 2369
105 1973 2087115 2353 2335125 2689 2413135 1947 1508145 856 538
155 702 325165 276 78175 307 29180 548
0-30 13729 27.530-60 14239 28.560-90 6641 13.3
0-90 34608 69.290-180 11682 23.40-180 46290 92.6
39663
2000 CD/DIV
10
20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
ZONALDEGREES
TOTALEFFIC.
O U T P U T D ATATEST OF HOLOPHANE PSCP1HP00XXC35
POSITION OF LAMP Set Position
LAMP 1000W COMPACT HPS LUMENS 125,000
WATTS 1000 BULB TYPE ED-37
TEST DISTANCE 25 ft S.C. 1.7
TESTED BY CERTIFIED BY
TEST NO.
pfcpccpw
RC
R
0 .97 .97 .97 .79 .79 .79 .681 .83 .79 .76 .68 .66 .64 .552 .72 .67 .62 .60 .56 .53 .463 .64 .57 .52 .53 .49 .45 .394 .57 .50 .44 .47 .42 .39 .335 .51 .43 .38 .42 .37 .33 .296 .45 .38 .33 .38 .33 .29 .257 .41 .34 .29 .35 .29 .26 .228 .37 .30 .26 .32 .26 .23 .199 .34 .27 .23 .29 .24 .20 .1710 .31 .25 .20 .27 .22 .18 .15
0°30° 30°
60°60°
90° 90°
120° 120°180°150° 150°
45525
5000 CD/DIV
0 5101520
2530354045
5055606570
7580859095
105115125135145
155165175180
1808118694188052074823118
2501828060311232879723891
1714311272 7271 5499 5450
5414 5679 5814 5330 5351
5448 5358 4906 3767 2624
2516 548 345 297
1784
5881
11580
19551
18502
10113
5458
5728
6343
5838
5764 5319 4401 2917 1648
1165 155 33
19246 48166 17529 84941 27241112182
15.438.514.068.021.889.7
0-30 30-60 60-90 0-9090-180 0-180
20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
ZONALDEGREES
TOTALEFFIC.
O U T P U T D ATATEST OF HOLOPHANE PSC10HP00XXC35
POSITION OF LAMP Set Position
LAMP 1000W Clear HPS LUMENS 140,000
WATTS 1000 BULB TYPE ED-25
TEST DISTANCE 25 ft S.C. .8
TESTED BY CERTIFIED BY
TEST NO.
pfcpccpw
RC
R
0 .91 .91 .91 .73 .73 .73 .611 .78 .75 .72 .62 .60 .58 .492 .69 .63 .59 .55 .52 .49 .413 .61 .55 .50 .49 .45 .42 .354 .54 .48 .43 .44 .40 .36 .315 .49 .42 .37 .40 .36 .32 .276 .44 .38 .33 .37 .32 .29 .247 .41 .34 .30 .34 .29 .26 .228 .37 .31 .27 .31 .27 .23 .209 .34 .28 .24 .29 .25 .21 .1810 .32 .26 .22 .27 .23 .20 .17
0°30° 30°
60°60°
90° 90°
120° 120°180°150° 150°
45522
8000 CD/DIV
0 5101520
2530354045
5055606570
7580859095
105115125135145
155165175180
0-30 30-60 60-90 0-9090-180 0-180
5275749621439944049533828
2715121859199181809716704
1451511805 9639 7516 6247
5692 5965 6295 6090 6383
6633 6996 7391 5498 3971
2025 869 845 654
4737
11479
12567
12513
12936
10591
7461
6021
6868
6964
7017 6945 6631 4258 2495
937 246 81
28783 36040 20350 85172 35573120745
20.625.714.560.825.486.2
PRISMALUME®
9 HOLOPHANE®
Photometric Data — Metal Halide
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
ZONALDEGREES
TOTALEFFIC.
O U T P U T D ATATEST OF HOLOPHANE PRSL400MH00XXE31
POSITION OF LAMP Set Position
LAMP 400W Clear MH LUMENS 36000
WATTS 400 BULB TYPE E-37
TEST DISTANCE 25 ft S.C. = 1.6
TESTED BY CERTIFIED BY
TEST NO.
pfcpccpw
RC
R
0 .97 .97 .97 .81 .81 .81 .711 .84 .81 .78 .71 .69 .67 .592 .74 .69 .64 .62 .59 .56 .503 .65 .59 .54 .56 .51 .48 .424 .58 .51 .46 .50 .45 .41 .375 .52 .45 .40 .45 .40 .36 .326 .47 .40 .35 .40 .35 .31 .287 .42 .35 .30 .37 .32 .28 .248 .38 .32 .27 .33 .28 .25 .229 .35 .28 .24 .31 .26 .22 .19
.32 .26 .21 .28 .23 .20 .17
0°30° 30°
60°60°
90° 90°
120° 120°180°150° 150° 0 72225 6730 642
10 657515 6763 191720 7038
25 7481 346330 833035 9777 614240 1103445 8354 6470
50 475755 2655 238260 193365 1588 157670 1471
75 1358 143780 123085 1137 124190 98395 1033 1127
105 1221 1291115 1221 1212125 1040 933135 920 713145 1065 669
155 783 363165 219 62175 157 15180 119
0-30 6022 16.730-60 14993 41.660-90 4254 11.8
0-90 25269 70.290-180 6384 17.70-180 31653 87.9
40946
1500 CD/DIV
10
20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%
20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
ZONALDEGREES
TOTALEFFIC.
O U T P U T D ATATEST OF HOLOPHANE PRSL400MH00XXE31
POSITION OF LAMP Set Position
LAMP 400W Coated MH LUMENS 36,000
WATTS 400 BULB TYPE E-37
TEST DISTANCE 25 ft S.C. 1.5
TESTED BY CERTIFIED BY
TEST NO.
pfcpccpw
RC
R
0 .96 .96 .96 .77 .77 .77 .651 .82 .78 .74 .65 .63 .61 .512 .71 .65 .61 .57 .54 .50 .423 .62 .56 .51 .50 .46 .43 .364 .55 .48 .43 .45 .40 .37 .315 .49 .42 .37 .40 .35 .32 .276 .45 .37 .32 .36 .32 .28 .237 .40 .33 .28 .33 .28 .24 .208 .37 .30 .25 .30 .25 .22 .189 .33 .27 .22 .28 .23 .19 .1610 .31 .24 .20 .26 .21 .18 .15
0°30° 30°
60°60°
90° 90°
120° 120°180°150° 150°
40947
5000 CD/DIV
0 5101520
2530354045
5055606570
7580859095
105115125135145
155165175180
0-30 30-60 60-90 0-9090-180 0-180
64656508648864986457
67157367763770875641
41303052246220581863
17231716166715821631
16871687161815021261
815 293 171 113
621
1842
3108
4798
4368
2738
2043
1822
1819
1780
1785167514521163 792
377 83 16
557111904 568423159 912332283
15.533.115.864.325.389.7
20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
ZONALDEGREES
TOTALEFFIC.
O U T P U T D ATATEST OF HOLOPHANE PRSL400MH00XXE31PS40RMH00XXM31 MAG. REG. BALLAST
POSITION OF LAMP Set Position
LAMP 400W Clear SMH LUMENS 40,000
WATTS 400 BULB TYPE BT-37
TEST DISTANCE 25 ft S.C. 1.6
TESTED BY CERTIFIED BY
TEST NO.
pfcpccpw
RC
R
0 .96 .96 .96 .80 .80 .80 .691 .84 .80 .77 .70 .68 .66 .572 .74 .68 .64 .62 .58 .55 .483 .65 .59 .54 .55 .51 .47 .414 .58 .51 .46 .49 .44 .41 .365 .52 .45 .40 .44 .39 .35 .316 .47 .40 .35 .40 .35 .31 .277 .42 .35 .30 .36 .31 .27 .248 .38 .32 .27 .33 .28 .24 .219 .35 .28 .24 .30 .25 .22 .1910 .32 .26 .21 .28 .23 .20 .17
0°30° 30°
60°60°
90° 90°
120° 120°180°150° 150°
41001
2000 CD/DIV
0 5101520
2530354045
5055606570
7580859095
105115125135145
155165175180
0-30 30-60 60-90 0-9090-180 0-180
8937 7938 7424 7602 7798
8086 89051028511540 9293
5384 2850 1996 1607 1568
1468 1338 1246 1106 1178
1416 1444 1225 1132 1443
1681 259 173 132
758
2155
3743
6461
7197
2557
1595
1553
1359
1286
149814331099 877 907
778 73 16
665516214 450727376 796735343
16.640.511.368.419.988.4
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
ZONALDEGREES
TOTALEFFIC.
O U T P U T D ATATEST OF HOLOPHANE PRSL400MHXXPDB35
POSITION OF LAMP Set Position
LAMP 400W Clear MH LUMENS 36000
WATTS 400 BULB TYPE E-37
TEST DISTANCE 25 ft S.C. = 1.1
TESTED BY CERTIFIED BY
TEST NO.
pfcpccpw
20%70%50% 30% 10% 50% 30% 10% 0%
30% 0
RC
R
0 .93 .93 .93 .76 .76 .76 .641 .82 .80 .77 .68 .66 .65 .562 .74 .70 .66 .62 .59 .57 .503 .67 .62 .58 .57 .53 .51 .454 .61 .56 .51 .52 .48 .46 .405 .56 .50 .46 .48 .44 .41 .376 .51 .46 .41 .44 .40 .37 .337 .47 .42 .37 .41 .37 .34 .318 .44 .38 .34 .38 .34 .31 .289 .41 .35 .31 .36 .32 .29 .26
.38 .32 .29 .33 .29 .26 .24
0°30° 30°
60°60°
90° 90°
120° 120°180°150° 150° 0 129985 12905 1232
10 1283615 12876 365020 12561
25 12532 580130 1435835 12164 764140 527645 1916 1484
50 116555 918 82460 84065 865 85870 894
75 852 90280 82385 800 87290 86495 1130 1233
105 1796 1900115 1571 1560125 725 650135 1235 956145 1671 1049
155 882 408165 96 27175 95 9180 118
0-30 10682 29.730-60 9949 27.660-90 2632 7.3
0-90 23264 64.690-180 7793 21.60-180 31057 86.3
39649
2000 CD/DIV
10
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
ZONALDEGREES
TOTALEFFIC.
O U T P U T D ATATEST OF HOLOPHANE PRSL400MHXXPDE40
POSITION OF LAMP Set Position
LAMP 400W Clear MH LUMENS 36000
WATTS 400 BULB TYPE E-37
TEST DISTANCE 25 ft S.C. = .8
TESTED BY CERTIFIED BY
TEST NO.
pfcpccpw
20%70%50% 30% 10% 50% 30% 10% 0%
30% 0
RC
R
0 .97 .97 .97 .78 .78 .78 .671 .85 .82 .79 .69 .67 .66 .562 .76 .71 .67 .63 .60 .57 .503 .69 .63 .59 .58 .54 .51 .454 .63 .57 .52 .53 .49 .46 .415 .58 .52 .47 .49 .45 .42 .386 .54 .47 .43 .46 .42 .39 .357 .50 .44 .39 .43 .39 .36 .328 .46 .41 .36 .41 .37 .33 .309 .44 .38 .34 .38 .34 .31 .28
.41 .35 .32 .36 .32 .29 .27
0°30° 30°
60°60°
90° 90°
120° 120°180°150° 150° 0 243615 23347 2229
10 2238115 21353 605320 16255
25 11805 546430 667135 3835 240940 296245 2905 2249
50 303455 2317 207960 88065 1099 109170 1215
75 1354 143280 144185 1368 149390 117995 1177 1284
105 1391 1471115 1990 1976125 2148 1927135 1019 789145 715 449
155 899 416165 204 58175 203 19180 303
0-30 13745 38.230-60 6737 18.760-90 4016 11.20-90 24499 68.1
90-180 8390 23.30-180 32888 91.4
39625
4000 CD/DIV
10
20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
ANGLEDEGREES
CANDLEPOWER
LUMENS
ZONALLUMENS
ZONALDEGREES
TOTALEFFIC.
O U T P U T D ATATEST OF HOLOPHANE PSC10MH00XXB40
POSITION OF LAMP Set Position
LAMP 1000W Clear MH LUMENS 110,000
WATTS 1000 BULB TYPE BT-56
TEST DISTANCE 25 ft S.C. 1.1
TESTED BY CERTIFIED BY
TEST NO.
pfcpccpw
RC
R
0 1.00 1.00 1.00 .81 .81 .81 .681 .87 .83 .80 .70 .68 .66 .562 .77 .71 .67 .62 .59 .56 .483 .69 .62 .57 .56 .52 .49 .424 .62 .50 .50 .51 .47 .43 .375 .56 .49 .44 .47 .42 .38 .336 .51 .44 .39 .43 .38 .34 .307 .47 .40 .35 .39 .35 .31 .278 .43 .36 .32 .36 .32 .28 .249 .40 .33 .29 .34 .29 .26 .2210 .37 .30 .26 .32 .27 .24 .21
0°30° 30°
60°60°
90° 90°
120° 120°180°150° 150°
45329
6000 CD/DIV
0 5101520
2530354045
5055606570
7580859095
105115125135145
155165175180
0-30 30-60 60-90 0-9090-180 0-180
3223531857331603693837363
3513329600219591515511884
10362 8606 6394 3696 4013
4248 4668 5042 4756 4693
4454 5059 6573 6630 2890
2375 739 599 693
3041
10471
16262
13795
9203
7721
3669
4494
5501
5120
4711 5021 5897 5135 1815
1099 209 57
29774 30720 13664 74157 29066103223
27.127.912.467.426.493.8
10
PRISMALUME®
HOLOPHANE®
Complete luminaire shall be Holophane catalog
number ________. The luminaire shall consist of
two sub-assemblies: ballast assembly containing the
electrical components, mounting hardware and
reflector attachment lugs; and optical reflector. It
shall have passed .5g accelerated fatigue vibration
test, high ambient temperature test of _________,
and provide for lamp starting in -20°F (MH/MV),
-40°F (HPS) ambients.
The complete luminaire shall be UL listed to US and
Canadian safety standards, Inc. as suitable for use in
damp location ambients of up to 55°C as standard,
65°C optional.
The die cast aluminum ballast housing shall be
protected against corrosion by a seven stage pre-
treatment process followed by a sprayed on white
polyester powder paint, cured and baked on at
218°C; which exceeds ASTM standard practice for
hardness, humidity, impact and salt spray resistance
to prevent cross hatch creep, fading, cracking, and
other corrosion related deterioration.
The pre-wired, porcelain enclosed lamp holder with
corrosion resistant, nickel plated lamp grip screw
shell, shall be factory set for optimum distribution.
The zinc plated steel, reflector attachment yoke shall
have swingover locking lugs and provision for full
ventilation and optional safety chain. No tools shall
be required to attach or detach the reflector from
the housing while installed.
Optional Mounting Methods (Choose One)
(See pg. 15 for C/UL/US temperature listings)
P/PD - Pendant
The separable .75” NPT threaded conduit
mounting plate with integral set screw shall
provide quick install unidirectional luminaire slide
on attachment. Housing shall be balanced and
suitable for support from hooks or loops without
field adjustment.
Wireway cover shall enclose the fast splice wiring
chamber which is suitable for 90° supply wire.
N/ND - Non-Disconnect Pendant and
Throughway Wiring
The die cast aluminum pendant and/or
throughway integral wiring box shall contain
provisions for both .75” NPT conduit and direct
ceiling mounting. It shall contain an integral
hinge which connects with the die cast
aluminum pin on the housing to support the
luminaire while electrical splices are made. It
shall have the same corrosion resistant finish as
the housing. It shall have 2 cast in side
knockouts, 4 ceiling mount drill points, .75” NPT
conduit threaded top opening, and be C/UL/US
certified for up to five #10 AWG conductors for
through wiring.
The housing shall swing up and connect to the ND
box by latching the captive J bolt and wing nut
without use of tools.
Q/QD - Quick-Disconnect Pendant and
Throughway Wiring
The die cast aluminum pendant and/or
throughway quick disconnect wiring box shall
contain provisions for both .75” NPT conduit and
direct ceiling mounting. It shall contain an
integral hinge which connects with the die cast
aluminum or stainless steel hinge pin on the
housing to allow the luminaire to hang free with
electrical disconnect. It shall have the same cor-
rosion resistant finish as the housing. It shall
have 2 cast in side knockouts, 4 ceiling mount
drill points, .75” NPT conduit threaded top
opening, and be capable of carrying up to five
#10 AWG conductors for through wiring.
The housing shall swing up and connect to the QD
box by latching the captive J bolt and wing nut
without use of tools.
A dead front female receptacle shall be mounted
inside the QD box which will make an electrical
connection with the pre-wired male plug on the
housing.
The receptacle shall be C/UL/US for connection to
lighting branch circuits which can then be energized
before the housing is attached. The grounding
connection shall be the first to make contact and the
last to disconnect.
It shall be C/UL/US listed per UL-1059 (Panel Board
Accessory) and UL-98 (Enclosed and Dead Front
Switches) permitting the fixture to be disconnected
while under load.
PF - Mounting Hooks and Loops
Mounting hooks and loops shall be lubricating
malleable cast iron and protected against corrosion
with zinc plated yellow chromate finish.
Optical Assembly
Glass reflector shall be Endural® prismatic borosil-
icate glass with a minimum wall thickness of
3mm (.13"). Reflector shall be supported by
three 5mm (.19”) min. dia. steel rods bolted to a
bottom retaining ring made of concentric rings of
6mm (.22”) min. dia. steel rod.
When tested with a ________ watt ________ lamp,
zonal outputs shall be not less than:
Zonal %total
degrees lamp
lumens
0 - 30 ______________________
30 - 60 ______________________
60 - 90 ______________________
0 - 90 ______________________
90 - 180 ______________________
Luminaire shall have a spacing criteria of ________.
The physical properties of the Holophane Prismalume® Seriesluminaires represent typical average values obtained inaccordance with accepted test methods and are subject tonormal manufacturing variations. They are supplied as atechnical service and are subject to change without notice.Check with your local Holophane sales representative toassure current information.
Performance Specification
How to construct a catalog number for Prismalume Fixture type___________
EXAMPLE: PRSL — 400HP —12 — PD — M35 — F1 Fill in — — — — — 1 2 3 4 5 6 cat. no.: 1 2 3 4 5 6
Catalog no. Description
1 Luminaire__ PRSL Prismalume__ PS Prismalume
2 Source and wattagePRSL__ 15AHP 150W/55V HPS__ 25LHP 250W HPS, energy saving ballast__ 250HP 250W HPS__ 40LHP 400W HPS, energy saving ballast__ 400HP 400W HPS__ 175MP1 175W MH, protected lamp__ 250MP1 250W MH, protected lamp__ 250PP1 250W MH, pulse start, protected lamp__ 25LMP1 250W MH, protected lamp, energy saving ballast__ 25LPP1 250W MH, pulse start, protected lamp, energy saving ballast__ 320PP1 320W MH, pulse start, protected lamp__ 350PM 350W MH, pulse start__ 35LPM 350W MH, pulse start, energy saving ballast__ 400MH 400W MH __ 40LMH 400W MH, energy saving ballast__ 400PM 400W MH, pulse start__ 40LPM 400W MH, pulse start, energy saving ballastPS__ 750HP 750W HPS (not available with MT, VT)__ 750PM 750W MH, pulse start__ CP1HP 1000W HPS, compact lamp__ C10HP 1000W HPS__ 40RMH 400W MH, Mag Reg (not available with MT, VT)__ C10MH 1000W MH
3 Voltage__ 12 120 volt__ 20 208 volt__ 24 240 volt__ 27 277 volt__ 34 347 volt__ 48 480 volt__ MT Multi-voltage (120 - 277V USA)__ VT Vari-tap (120, 277, 347V Canada and 250HP, 400HP, 400MH only)
4 MountingPRSL PS__ PD __ P Pendant mount for .75” NPT conduit__ QD __ Q Quick disconnect power hanger for pendant and thru-way wiring. Not available with “CDP”, “PHCB” or “PF”.__ ND __ N No quick disconnect power hanger for pendant and thru-way wiring
5 OpticsSelect reflector catalog no. from matrix on page 7 for desired spacing and wattage
6 Options and AccessoriesSee pages 14 and 15 for available options and accessories.
Note: 1 These fixtures use sockets that accept open fixture rated lamps only. Standard mogul base lamps are not compatible.
Order number____________ Job name______________
PRISMALUME®
13 HOLOPHANE®
Ordering Data
Drawing #1Diameter PD QD, ND
Optics Reflector mm (in.) mm (in.) mm (in.)31 PRSL31 400 (15.90) 640 (25.15) 700 (27.55)35 PRSL35A 400 (15.90) 640 (25.15) 700 (27.55)37 PRSL37 410 (16.15) 610 (24) 670 (26.40)39 PRSL39 480 (18.90) 630 (24.55) 690 (26.95)40 PRSL40 560 (21.90) 630 (24.55) 690 (26.95)50 PRSL50 690 (26.95) 780 (30.65) 840 (33.05)
Drawing #2Diameter P Q, N
Optics Reflector mm (in.) mm (in.) mm (in.)31 PRSL31 400 (15.90) 710 (28.10) 770 (30.50)35 PRSL35A 400 (15.90) 710 (28.10) 770 (30.50)37 PRSL37 410 (16.15) 680 (26.60) 740 (29)39 PRSL39 480 (18.90) 700 (27.55) 760 (29.95)40 PRSL40 560 (21.90) 700 (27.55) 760 (29.95)50 PRSL50 690 (26.95) 850 (33.60) 910 (36)
QD,ND
PD
Dia.Drawing #1 — 150-400W
Q, N
P
Dia.
Drawing #2Mag reg, 750 and 1000W
PRSL PS
14
PRISMALUME®
HOLOPHANE®
Options
Catalognumber Description
Options (Factory installed)__ F1 Single fuse assembly for 120, 240, 277, 347V. NA with “MT” or “VT”__ F2 Double fuse assembly for 208, 240, 480V. NA with “MT” or “VT”__ PF-105 Loop, malleable iron .75” NPT male; all fixtures except “Q”,“QD”__ PF-121 Safety hook, malleable iron .75” NPT male; all fixtures except “Q”,“QD”__ PF-129 Anti-rotational hook, malleable iron .75” NPT male; all fixtures except “Q”,“QD”__ PF-291 Universal gasketed hook assembly malleable iron .75” NPT male__ 65 For use in 65°C ambients (available for 40LMH, 40LPM, 40LHP, C10HP, C10MH only)__ CDP-L5-15-X (120V) 120V three foot, three conductor cord and NEMA plug (order “PF” also) (X = No. of feet. 3 feet is standard)__ CDP-L6-15-X (208/240V) 208/240V, three conductor cord and NEMA plug (order “PF” also) (X = No. of feet. 3 feet is standard)__ CDP-L7-15-X (277V) 277V, three conductor cord and NEMA plug (order “PF” also) (X = No. of feet. 3 feet is standard)__ CDP-L24-20-X (347V) 347V, three conductor cord and NEMA plug (order “PF” also) (X = No. of feet. 3 feet is standard)__ CDP-L8-20-X (480V) 480V, three conductor cord and NEMA plug (order “PF” also) (X = No. of feet. 3 feet is standard)__ EM1 Standby lighting fixture uses a D.C. bayonet base, 250W (max.) tungsten halogen lamp (included) to provide standby lighting. (Not
available with 750HP, 277 or 480V)__ ER1 Emergency lighting fixture less relay for use with a 120 volt external power source to operate a D.C. 250W (max.) bayonet base tungsten
halogen lamp (included) to provide emergency lighting. (All fixtures except “CDP”, “PHCB”, “Q” or “QD”.) (Includes Tee condulet). NotCSA certified
__ TD1 Standby lighting fixture. Appropriate halogen-tungsten lamp and Time Delay relay are supplied with fixture. Not available with “EM”,“ER” or “65”. Limited to 40°C ambient.
__ PS HPS protected starter__ PHCB (120, 208, 240, 277, 347V) Power-hook cord, special configuration plug cap and “PF-105” loop attached (use with “UPH-35” or “UPH-36”); all fixtures except
“MT”, “-ER”, “Q” or “QD”__ PHCB-L8-480 (480V) Power-hook cord, special configuration plug cap and “PF-105” loop attached (use with “UPH-35-L8-480” or “UPH-36-L8-480” on 480
volt units only); all fixtures except “-ER”, “Q”, or “QD”__ H HALT® Automatic lamp time-out. Available on MH or PM units only. Not available on units with Pulse Metal Halide in combination with
“EM”, use TD instead. MT or VT available through TSG. Customer specifies voltages to be wired. 55°C max.__ D35 AERS®- Automatic Energy Reduction System low voltage DC control handled through TSG. DC control module, sensors, and Holoflex® must
be specified through TSG. 40°C listed. Available with 250HP, 25LHP, 400HP, 40LHP. Not available with “QD”, “CDP”, “PHCB”, or “EM”.__ D50 AERS®- Automatic Energy Reduction System low voltage DC control handled through TSG. DC control module, sensors, and Holoflex®
must be specified through TSG. 40°C listed. Available with 15AHP, 175MP, 250HP, 25LHP, 250MP, 25LMP, 250PP, 25LPP, 320PP, 350PM,35LPM, 400HP, 40LHP, 400MH, 40LMH, 400PM, 40LPM. Not available with “QD”, “CDP”, or “PHCB”.
__ A35 AERS®- Automatic Energy Reduction System line voltage AC control handled through TSG. AC control module, sensors, and Holoflex® mustbe specified through TSG. 40°C listed. Available with 250HP, 25LHP, 400HP, 40LHP. Not available with “QD”, “CDP”, “PHCB”, or “EM”.
__ A50 AERS®- Automatic Energy Reduction System low voltage AC control handled through TSG. AC control module, sensors, and Holoflex®
must be specified through TSG. 40°C listed. Available with 15AHP, 175MP, 250HP, 25LHP, 250MP, 25LMP, 250PP, 25LPP, 320PP, 350PM,35LPM, 400HP, 40LHP, 400MH, 40LMH, 400PM, 40LPM. Not available with “QD”, “CDP”, or “PHCB”.
__ HFW Holoflex® flexible wiring system__ CR Extra heavy duty corrosion resistant finish__ 08214-3 Chain, .92m (3’)
Note: 1 See page 17 for a further description of “EM”, “TD” and “ER”.
UPH-35
PHCB Power-hook
Ballast housing
Thru-way UPH-35 Mounting Detail UPH-35 Pendant UPH-36
88mm (.31”) x 10mm (.38”)ceiling mounting (2) places
110mm(4.31”)
DN20NPT (.75”)threaded entry
22mm (.88”)
(2) wiring accesscovers
(2) KO’s forDN20 (.75”)conduit
120mm(4.88”)
130mm(4.94”)
30mm(1.06”)
110mm(4.5”)
PRISMALUME®
15 HOLOPHANE®
Accessories
Ambient Temperature C/UL/US Listing Mounting OptionN, ND (Non-Disconnect) Q, QD (Quick Disconnect)
Lamp Wattage, Ballast Type P, PD Through No Through Through No Through(Pendant) Wiring Wiring Wiring
WiringMetal Halide, 90°C Building Wire400W Peak Lead 55°C 55°C 55°C 55°C 55°C400W EM, Peak Lead 55°C 55°C 55°C 55°C 55°C400W Mag Reg 55°C 55°C 55°C 55°C 55°C400W EM, Mag Reg 40°C 40°C 40°C 40°C 40°C1000W Peak Lead 55°C 55°C 55°C 55°C 55°C1000W EM, Peak Lead 55°C 55°C 55°C 55°C 55°CMetal Halide, 105°C Building Wire1000W 65°C Option, Peak Lead 65°C N/A 65°C N/A 65°CHigh Pressure Sodium, 90°C Building Wire400W Lead 55°C 55°C 55°C 55°C 55°C400W EM, Lead 55°C 55°C 55°C 55°C 55°C400W Mag Reg 55°C 55°C 55°C 55°C 55°C400W EM, Mag Reg 40°C 40°C 40°C 40°C 40°C750W Lead 55°C 55°C 55°C 55°C 55°C750W EM Lead (120, 208, 240 Only) 55°C 55°C 55°C 55°C 55°C1000W Lead 55°C 55°C 55°C 55°C 55°C1000W EM, Lead 55°C 55°C 55°C 55°C 55°C1000W Compact Lamp, Lead N/A N/A N/A N/A 55°C1000W EM, Compact Lamp Lead N/A N/A N/A N/A 55°CHigh Pressure Sodium, 105°C Building Wire1000W 65°C Option, Lead 65°C N/A 65°C N/A 65°C1000W Compact Lamp, Lead 55°C N/A 55°C N/A See 90°C Wire
Catalog number DescriptionAccessories (shipped separately)
__ LAMP Appropriate HID lamp supplied with fixtures__ PF-105-B Loop, malleable iron .75” NPT male; not available with “Q”,“QD”__ PF-116-A Loop, malleable iron .75” NPT female; not available with “Q”,“QD”__ PF-121-A Safety hook, malleable iron .75” NPT male: not available with “Q”,“QD”__ PF-122-A Safety hook, malleable iron .75” NPT female; not available with “Q”,“QD”__ PF-129-A Anti-rotational hook, malleable iron .75” NPT male: not available with “Q”,“QD”__ PF-291 Universal gasketed hook assembly malleable iron .75” NPT male__ UPH-35-XXX-WH Thru-way power-hook (order “PHCB” with fixture); not available with “MT”, “VT”, “-ER”, “Q” or “QD”. Insert voltage for XXX.
(120, 208, 240, 277, 347V)__ UPH-35-L8-480-WH Thru-way power-hook (order “PHCB-L8-480” with fixture); not available with“-ER”, “Q” or “QD” __ UPH-36-XXX-WH Pendant power-hook (order “PHCB” with fixture); not available with “MT”, “VT”, “-ER”, “Q” or “QD”. Insert voltage for XXX.
(120, 208, 240, 277, 347V)__ UPH-36-L8-480-WH (480V) Pendant power-hook (order “PHCB-L8-480” with fixture); not available with “-ER”, “Q” or “QD” __ WG-212-A Wire guard for open bottom PRSL35A and PRSL31 only__ WG-212-B Wire guard with relamping hole for open bottom PRSL35A and PRSL31 only __ WG-219-A Wire guard for open bottom PRSL37 only __ WG-219-B Wire guard with relamping hole for open bottom PRSL37 only __ GD-45 Wire guard with relamping hole for open bottom PRSL39 only
57mm(2.25”)
PF-105-BMalleable ironLoop.75” NPT male
PF-129-AMalleable ironAnti-rotational hook.75” NPT male
73mm(2.88”)
67mm(2.63”)
71mm(2.78”)
92mm(3.62”)
45mm(1.75”)
PF-121-AMalleable ironSafety hook, .75” NPT male
PF-116-AMalleable ironLoop.75” NPT female
PF-122-AMalleable ironSafety hook, .75” NPT female
PF-291Malleable ironSafety hook,.75” NPT male
Holoflex
Fusing
16
PRISMALUME®
HOLOPHANE®
Fusing and Holoflex® Options
ND Mount fuse option: in linefuses are available for fieldinstallation
PD Mount fuse option: fuseholder attaches to splice box coveras shown.
QD Mount fuse option: fuseholder is standard.
QD Fuse holder: is available assingle fuse “F1” for 120, 240,277 and 347V; double fuse“F2” available for 208, 240 and480V.
PD Mount single fuseassembly “F1”: available for120, 240, 277 or 347V.
PD Mount double fuseassembly “F2”: available for208, 240 or 480V
HFW - Lighting “L” cord drop
Three circuit power distributionDistribution Box Cable
Extender CableLighting Fixture Drop
Distribution Box Cable
Home Run Cable
Lighting Panel
ND Mount fuse option
PD Mount fuse option
QD Mount fuse option PD Mount double fuse assembly
PD Mount single fuse assembly
QD Fuse holder
Holoflex® wiring
A modular single or three phasewiring system that providesflexibility in layout, quick installa-tion and lower installed cost.
Holoflex® system benefits
• Labor saving installation
• Flexibility; fixtures may be easilyrelocated without costlyelectrical system modifications
• Replaces power-hook and cordassemblies
• Ease of maintenance
• Possible tax advantages
• For additional information onHoloflex, see brochure HL-992
HALT®
EM, TD, ER
PRISMALUME®
17 HOLOPHANE®
Standby, Emergency and HALT™ Options
UL 1598 listed standby lightsystems
EM: When an HID lamp isextinguished due to a momentarypower interruption, and power isimmediately restored, an internalrelay energizes a tungsten halogenlamp (QCL/DC) until the HID lamprestrikes, at which time thetungsten halogen lamp switchesoff.
TD: When power is supplied orrestored to the fixture, an internalrelay energizes a tungsten/halogenlamp. The tungsten/halogen lampremains energized for a periodduring and following the HID lamprestrike as the HID lamp energizes.Following the delay period thetungsten/halogen lamp turns offprior to the HID lamp reaching fullluminance.
HALT® — Holophane Auto-matic Lamp Time-out (patentpending)
H: Designed for metal halidefixtures operating 24 hours perday, 7 days per week, the HALTdevice will extinguish the individualluminaire’s lamp for 15 minutes,once per week at random times,complying with lamp manufac-turers’ turn-off recommendations.HALT reduces the potential fornon-passive end of life lamp failurewhile eliminating the inconven-ience of manual or time controlswitching. For additional informa-tion see Holophane brochure HL-1926.
UL 924 listed emergencyfixture
ER: When an HID lamp isextinguished due to a powerfailure, 120V auxiliary power maybe supplied directly to a tungstenhalogen lamp. Tee condulet in-cluded. Not CSA certified.
HALT device insideballast housing.
AERS® — Low voltage control wiring
Sensor Locations
Control Module
12 Volt or 24 Volt Low VoltageDC Control Wiring(Class II)
Line Voltage Feeds
18
PRISMALUME®
HOLOPHANE®
AERS® Options
AERS® luminaire
The standard Holophane lumin-aire is designed with a modifiedballast and relay. The modifiedballast is designed to operate thelamp at two input wattages: HPS,normal input like a standardluminaire, and a reduced inputeither 35% or 50% of full input;and metal halide, normal inputand a reduced input of 50%. Therelay is wired to an occupancysensor (or some type of contactclosure) through a control moduleallowing the luminaire to switchbetween the two input wattages.The relay signals the ballast whichinput wattage to supply the lampat any time.
Low voltage control
The AERS system can be installedseparately from the main powerdistribution using low voltage DCcontrol wiring. Each controlmodule is designed to handle up
AERS® — AC Power control wiring
Holoflex® Power Distributionwith AERS® Control
AERS® — AC Holoflex®
Control Module
Conduit
Distribution Panel
Zone 1
Zone 2
Zone 3
For additional information see HL-1161
Sensor Locations
to six zones. This system is idealfor adding AERS control to installa-tions with existing power distribu-tion.
Line voltage control
AERS is also available using linevoltage control wiring. Line powerand control wiring can runtogether through the same con-duit. (Not available with Q, QDH,CDP or PHCB).
Line voltage/ Holoflex control
Holophane has incorporatedAERS® into its Holoflex flexiblewiring system. Line power andcontrol wiring are fed through asingle cable. The AERS controlmodule is designed to handle upto three zones. This system is idealfor installing AERS into new instal-lations.
PRISMALUME®
19 HOLOPHANE®
This installation photo demon-strates the effect of HolophanePrismalume luminaires withprismatic glass reflectors in amanufacturing environment.Prismalume luminaires illuminatethe left half of this productionfacility. The right half of the photoillustrates the inadequate lightingfrom aluminum reflector unitsoriginally used in this application.Prismalume’s prismatic glass opticsdeliver improved horizontal andvertical illumination. Additionally,the uplight component from thePrismalume luminaires illuminatesthe ceiling space, eliminating the“cavern effect”. Workers exper-ience increased visual comfortand less eyestrain, resulting inincreased productivity.
Prismalume Glass Aluminum Reflector
HL-755 8/02 ©2002 Acuity Brands, Inc Printed in USA
Acuity Lighting Group, Inc.
214 Oakwood Ave., Newark, OH 43055 /Holophane Canada, Inc. 9040 Leslie Street, Suite208, Richmond Hill, ON L4B 3M4 / HolophaneEurope Limited, Bond Ave., Milton Keynes MK11JG, England / Holophane, S.A. de C.V.,Apartado Postal No. 986, Naucalpan de Juarez,53000 Edo. de Mexico
Contact your local Holophane factory salesrepresentative for application assistance, andcomputer-aided design and cost studies. Forinformation on other Holophane products andsystems, call the Inside Sales Service Departmentat 740-345-9631. In Canada call 905-707-5830 or fax 905-707-5695.
Limited Warranty and Limitation of LiabilityRefer to the Holophane limited materialwarranty and limitation of liability on thisproduct, which are published in the “Terms andConditions” section of the current productdigest, and is available from our local Holophanesales representative.
Visit our web site at www.holophane.com