horizon presentation
TRANSCRIPT
specialists in automated systems
Special Purpose Machines
- Design & Build- Validation- Integration- Consultancy- Distribution
From bench-top equipment...
...to full-scale production
25 Years Experience
Bespoke Automation
Reagent Deposition-Slot coating
(Image removed for confidentiality)
Deposition – Contact Plotting
Deposition - Spraying Equipment
Droplet Formation- Microlitre - Nanolitre - Picolitre
-
Distribution ~Microdispensing Technology
• Micro-dispensing – Nanotechnology Applications
• Patented Deposition Method• OEM & Workstations
- Marking & Ablation
- Cutting and Welding
- Laser Safety
- Fume Extraction
Laser Integration – YAG - Diode - CO2
Laser Transmission Welding of PolymersDistribution
Test Strip Lamination
Vision Systems
- Quality Control
- Pick and Place
- Line & Area Scan
- Measurement
- Customised Screens
Vision Systems
In-house Control Software
• PC or PLC• Full integration• Software validation• Windows-based user interfaces
where appropriate
Software Validation Support
- 21CFR11
- GAMP5
- Audit trail
- Electronic records
- FMEA & risk assessments
A few examples...
Proof of Principle / Hand Assembly
Deposition of Reagent into liquid nitrogenDeposition of Reagent into liquid nitrogen
Alignment of Adhesives into a Medical Device
Alignment and lamination of adhesive layer onto band - medical device
Integration of standard label applicator - medical device pilot line
Accurate punching of alignment holes in thin film layer
Complex Component Assembly
- Reel Fed Substrate- Laser Safety
Laser Integration
- Laser Integration- Microfluidic Device
Metered Dose Inhalers
- Shaking- Drug Collection- Waste Shots
- Major Customer- Validated Systems- Used World-Wide
- Diabetes Test Strip Lamination- SCARA Robot with Integrated cameras
- Test Kit Manufacture- Inkjet Printing
- Detailed Vision Analysis- Error Marking
- Pick & Place of Ø600µm contact for biosensor- Accurate Pick & Place ±5µm
- Card Handling- Mesh Feed
- Ultrasonic Welding Station- Cleanroom Class 100,000
- Automatic Biosensor Testing - Current Measurement 0-10µA ±2µA
- Log of Calibration Data- 21CFR11 Compliance
Feed Nitrocellulose SheetCrop & Punch To Create Band Format
Band AlignmentAntibody Plotting and Vision Line Scan Inspection
Band AlignmentBlocking, Stabilising and Inspection
Band Drying – hot air systemAfter plotting at 75 deg CAfter Blocking & Stabilising at 55 deg C
Error Marking – Strip by StripBand Stacking – Good, Reject & QC stacks
Complete System
PLANNING & DEFINITIONPROCESS VALIDATION PLAN
PROCESS RISK ASSESSMENT
DESIGN SPECIFICATIONS & DEVELOPMENT
FUNCTIONAL SPECIFICATION (FS)(traced from URS)
ACCEPTANCE TEST PROTOCOL (FAT)(traced from QPP, FS
and HDS /SDS for high risk items)
HARDWARE DESIGN SPECIFICATION (HDS)(traced from FS)
SOFTWARE DESIGN SPECIFICATION (SDS)(traced from FS)
DRAWING PACKAGE FOR HARDWARE
PREPARATION OF SYSTEM INSTALLATION PLAN DOCUMENT (SIP)
MANUFACTURE BESPOKE HARDWARE ITEMS
ASSEMBLE MACHINE
CONFIGURE / CODE BESPOKE SOFTWARE ITEMS
CODE REVIEWS AND STRUCTURAL TESTING (depth depends on risk assessment)
SYSTEM BUILD
DEVELOPMENT TESTING
SYSTEM INTEGRATIONINTEGRATE SOFTWARE WITH HARDWARE
INTERNAL TESTING AGAINST FAT PROTOCOL
ACCEPTANCE TESTINGCUSTOMER WITNESSED FACTORY ACCEPTANCE TESTING
(FAT)
PREPARATION OFIQ/OQ/PQ PROTOCOLS
COMMISSIONING & QUALIFICATION
SYSTEM INSTALLATION AND COMMISSIONING TO SIP
INSTALLATION QUALIFICATION FOR PROCESS (IQ), OPERATIONAL QUALIFICATION FOR PROCESS (OQ),PERFORMANCE QUALIFICATION FOR PROCESS (PQ)
HARDWARE BUILD QUALITY TESTING
PREPARATION OF TECHNICAL CONSTRUCTION FILE (TCF)
SHIPMENT OF SYSTEM
USER REQUIREMENT SPECIFICATION (URS)
QUALITY & PROJECT PLAN (QPP)(traced from URS)
Design and Risk Assessment Review
Design and Risk Assessment Review
PROTOTYPING OF COMPLEX INTERFACES AND FUNCTIONS
PROOF OF CONCEPT STUDIES
SOFTWARE BUILD QUALITY TESTING
PURCHASE STANDARD HARDWARE AND SOFTWARE ITEMS
COMPILE / BUILD SOFTWARE
VALIDATION REPORT
CUSTOMER RESPONSIBILITY
HORIZON RESPONSIBILITY
SHARED RESPONSIBILITY
Design and Risk Assessment Review Design and Risk Assessment Review
CONFIGURATION MANAGEMENT SPECIFICATION (CMS)
Example of Lifecycle
Quality Management
• ISO 9001: 2000 accreditation
• All work carried out follows strict procedures
Summary of ServicesMechanical DesignElectrical DesignSoftware CodingMachine ShopAssemblyTest ValidationDocumentationDistribution partnershipsAfter Sales Support
Customers served:3M Abbott AstraZeneca British Biocell International Cambridge UniversityCarclo Technical Plastics Cozart BiosciencesDiagnostics for the Real World Eastman Biochemical Genesis Diagnostics Genosis GlaxoSmithKline HypoguardInverness Medical Innovations Ivax Pharmaceuticals
L3 TechnologyLifeScan Scotland – (a Johnson & Johnson company) MediSense Oxoid Phadia Porvair Sciences Provalis Diagnostics Randox Laboratories Scandinavian Micro Biodevices Stirling Medical Innovations Trinity Biotech UnipathVerax BiomedicalVivacta
specialists in automated systems