horz thrust
DESCRIPTION
Pumping thrustTRANSCRIPT
Calculation for Horizontal Thrust @ shutoff Condition
Data
1 Pump Head H 16.203 m
2 Discharge per pump q 0.5545 cumecs
3 Velocuity in Delivery pipe V 2.5 m/s
4 Diameter of Delivery Pipe d 0.55 m
5 Density of water to be pumped w 1000
Horizontal Thrust @ shutoff Condition =
Horizontal or Axial Thrust @ duty head=
(Pressure x Area x + ( Discharge x w x V))/9.81
=( H x 0.7854*d^2)
3849.565 + 141.3099
3990.875 Kg
=1.5*3990.88
5986.313
say 6000 Kg
Kg/m3
1.5 x Horizontal or Axial Thrust @ duty point Head
Horizontal Thrust @ shutoff Condition =
Calculation for Horizontal Thrust @ shutoff Condition
Horizontal Thrust @ shutoff Condition =
Horizontal or Axial Thrust @ duty head= (Pressure x Area x + ( Discharge x w x V))/9.81623666.8
5772.69 40.774725813.465
1.5 x Horizontal or Axial Thrust @ duty point Head