  • 7/23/2019 How to Identify and Diagnose Fan Failures on Sun SPARC Enterprise T5120/T5140/T5220/T5240/T5440 and Netra

    1/4

    10/27/2015 Document 1543162.1

    https://support.oracle.com/epmos/faces/DocumentDisplay?_adf.ctrl-state=23xpiyeyw_248&id=1543162.1 1/4

    How to Identify and Diagnose Fan Failures on Sun SPARC EnterpriseT5120/T5140/T5220/T5240/T5440 and Netra T5220/T5440 (Doc ID 1543162.1)

    In this Document

    Goal

    Solution

    References

    APPLIES TO:

    Sun SPARC Enterprise T5140 Server - Version All Versions and later

    Sun SPARC Enterprise T5120 Server - Version All Versions and later

    Sun SPARC Enterprise T5220 Server - Version All Versions and later

    Sun SPARC Enterprise T5440 Server - Version All Versions and later

    Sun Netra T5220 Server - Version All Versions and later

    Information in this document applies to any platform.

    GOAL

    The goal of this document is to provide guidance on How to Identify and Diagnose Fan Failures on Sun SPARC

    Enterprise T5120 / T5140 / T5220 / T5240 / T5440 and Netra T5220 / T5440 servers.

    Fan failures are typically made known to user by reporting a /SYS/FAN_FAULT LED indicator being ON.

    SOLUTION

    Determine which of the fan modules are faulty or failed, keeping in mind that there are usually multiple fan

    modules within a given system.

    Using the machine's service processor to perform diagnostics and fan module identification, the following output

    will be seen from issuing ILOM or ALOM commands:

    *Note: The Service Processors of T5XX family of servers are by default configured to operate under an ILOM shell,

    by default.You can create an ALOM compatibility shell if you prefer to use commands that resemble ALOM CMT

    commands to administer your server.

    Please see the following article for more information on How to Configure the ILOM for ALOM Compatibility Shell on

    T5120/T5220/T5140/T5240/T5440/T6320/T6340/Netra T5220/Netra T5440/Netra T6340 (Doc ID 1543116.1)

    Examples:

    For ILOMcommands:

    -> show faulty

    Target | Property | Value

    --------------------+------------------------+-------------------------------

    /SP/faultmgmt/0 | fru | /SYS/FANBD0/FM1

  • 7/23/2019 How to Identify and Diagnose Fan Failures on Sun SPARC Enterprise T5120/T5140/T5220/T5240/T5440 and Netra

    2/4

    10/27/2015 Document 1543162.1

    https://support.oracle.com/epmos/faces/DocumentDisplay?_adf.ctrl-state=23xpiyeyw_248&id=1543162.1 2/4

    Targets:

    PRSNT

    SERVICE

    F0

    F1

    Properties:

    type = Front Fan

    fault_state = Faulted show /SYS/FANBD0/FM1/F0/TACH

    /SYS/FANBD0/FM1/F0/TACH

    Targets:

    Properties:

    type = Fan

    class = Threshold Sensor value = 0000.000 RPM showenvironment (ILOM equivalent is -> show o table level all /SYS)

    ~snip~

    /SYS/LOCATE /SYS/SERVICE /SYS/ACT

    OFF ON

  • 7/23/2019 How to Identify and Diagnose Fan Failures on Sun SPARC Enterprise T5120/T5140/T5220/T5240/T5440 and Netra

    3/4

    10/27/2015 Document 1543162.1

    https://support.oracle.com/epmos/faces/DocumentDisplay?_adf.ctrl-state=23xpiyeyw_248&id=1543162.1 3/4

    sc> showfru

    ~snip~

    Component : /SYS/FANBD0

    Time Stamp : Thu, Dec 21 2000 12:17:06 GMT

    New_Status : 0x10 (PROXIED FAULT)

    Old_Status : 0x10 (PROXIED FAULT)

    Initiator : SCAPP

    Component : 50

    Message : TACH at /SYS/FANBD0/FM1/F0 has exceeded low non-recoverable threshold. showfaults -v (ILOM equivalent is -> show faulty)

    Last POST Run: Mon Oct 23 13:57:23 2000

    Post Status: Passed all devices

    ID Time FRU Class Fault

    1 Dec 21 12:16:34 /SYS/FANBD0/FM0 SP detected fault: TACH at

    /SYS/FANBD0/FM1/F0 has exceeded low non-recoverable threshold.

    From ALOM command:

    sc> showlogs -v (ILOM equivalent is -> show /SP/logs/event/list)

    Log entries since Jul 30 22:17:27

    ----------------------------------

    Jul 30 22:17:27: IPMI |critical: "ID = 57 : 07/30/2011 : 22:17:27 : Fan : /FB0/FM1/F0/TACH : Lower Non-

    recoverable going low : reading 0

  • 7/23/2019 How to Identify and Diagnose Fan Failures on Sun SPARC Enterprise T5120/T5140/T5220/T5240/T5440 and Netra

    4/4

    10/27/2015 Document 1543162.1

    https://support.oracle.com/epmos/faces/DocumentDisplay?_adf.ctrl-state=23xpiyeyw_248&id=1543162.1 4/4

    System Configuration: Oracle Corporation sun4v SPARC Enterprise T5120

    Memory size: 16256 Megabytes

    ~snip~

    ============================ Environmental Status ============================

    Fan sensors:

    ----------------------------------------------------------------

    Location Sensor Status

    ----------------------------------------------------------------

    SYS/FANBD0/FM1/F0 TACH failed (0rpm )