HOWTO : Text-Out Function

Connections

• Link RS-485 Lines– Link DVR 485 Lines with Camera’s RS-

485 Port

Camera Configuration - 1

• Main Menu->System Setup->Setup Tools->System Config

• Change Event-Out Item with left-right keys– Off->Text-Out

• Note– Baud rate

Camera Configuration - 2

• Configure the packet strings• Please “Enter” on text-out item

Camera Configuration - 3

• Edit the packet character.- Impossible editing character.

- Text Start header “$”- Text End header “#”

• Text Separator is the delimiter of between of multi-events.

• Memory parameter for DVR Setting

– Text Start– Text End– Line Delimiter

• Accept and reset camera.

Camera Configuration - 4

• Configure PVA Functions• Example:

– Global Motion Event Configuration, and event string send.

• Main Menu->PVA• Press enter on icon• Check icon• And Return to back• This Setup means :

– Global Motion Occurred» Send Event to Screen» Send Event to String» Send Event to Alarm

• Exit and overwrite.

DVR Configuration - 1

• Recording Start. (CAM1)• Connect Setup Menu

DVR Configuration - 2

• Connect DISPLAY menu• Check “Text-In”• Save and out.

DVR Configuration - 3

• Connect EVENT Menu• And Select Text-In Tab.• Click blank “Setup”

DVR Configuration - 4• Select RS-485• Input Transaction Start String

– Same as camera’s Text Start.• Input Transaction End String

– Same as camera’s Text End• Input Line Delimiter• Configure the communication

Environment. (Press setup button)• Press OK and out.

DVR Configuration - 5

• Input event title.

DVR Configuration - 6• Edit event action configuration• Save and out

Movie clips

• Alarm • Text-In Search